Loading...
HomeMy WebLinkAbout705 PALOMAR AIRPORT RD; 300; FPC2020-0103; PermitPERMIT REPORT Ccity of Carlsbad Print Date: 01/25/2022 Job Address: 705 PALOMAR AIRPORT RD, #300, Permit Type: FIRE-Construction Commercial Parcel #: 2101001600 Valuation: $277,106.58 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: CARLSBAD, CA 92011-1060 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0103 Status: Closed - Finaled Applied: 06/11/2020 Issued: 07/07/2020 Finaled Close Out: 08/17/2020 Inspector: Final Inspection: Project Title: Description: AEROTEK - PROVIDE & INSTALL HORNS & STROBES THROUGHOUT SPACE (16 DEVICES & 1 NEW POWER SUPPLY) FPContractor: RIVER FIRE AND SECURITY INC 8920 ACTIVITY RD, # STE SAN DIEGO, CA 92126-4458 (858) 752-6250 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov Frczoio o5 * S • SUBMITAL BOOK FOR: AEROTEK 705 PALOMAR AIRPORT RD., STE. 300 CARLSBAD CA 92011 RIVER FIRE AND SECURITY 8920 ACTIVITY RD. STE. J SAN DIEGO CA 92126 C 1 896646 CUTSHEETS AND CSFM LISTINGS FOR: 5495 POWER MODULE HSWC HORN STROBE 5495 Honeywell 3 sllBT. KNIGHT 5495 Distributed Power Module The 5495 Distributed Power Module is the most powerful and cost- effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor',Gentex ', AMSECO ". and Wheelock. The 6495's switch mode power SUpply design is up to 500/ more efficient than competitive linear mode power supplies. Also, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery. The 5495 is the costeffective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. CONNECTION TO LOCAL FIRE CONTROL The 5495 may be connected to a local fire control which utilizes Class Aor Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4,7kQ end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. FEATURES & BENEF I TS UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power uo to 501)/o more efficenty than other systems Dip Switches allow for easy reconfiguration 24VDC filtered output voltage Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs, 2 Class B or 2 Class A Ground fault detector! indicator Independent trouble relay AC loss delay option shut:.; off power to non - essent a high current accessories like magnetic door holders Built-in Operates with most synchronization for polarized. UL Listed appliances from notification devices System Sensor, ANSI Cadence pattern Gentex , AMSECO, output capability and Wheelock built-in Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal I Input Signal Circuit Output S' 12 Distributed Power Module 5495 Signal 2 ________ Signal 3 (Optional) Signal 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) 5495 Technical Specifications SUPERVISION The 5495 supervises a variety of functions including: Low AC power Low battery condition Earth ground fault Auxiliary output power limit condition EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. PHYSICAL Dimensions: 12.25W x 16H x 3D (30.88 cm VV x 40.64 cm H x 7.62 cm D) ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10% - 93% non-condensing) ELECTRICAL AC input: 120 VAC at 24 Output: 24 VDC at 64 Current: Standby 75mA; Alarm 205m4 Auxiliary power circuit: 1 Notification circuits 4 Output configuration:2 Class A (Style Z): 4 Class B (Style Y) (1 Class A & 2 Class B) Amps per output circuit: 3.0(6.0 amps total) Notification circuit output: Alarm Current (for typical voltages) drawn from main panels notification appliance circuits. 12 VDC 6.5 mA 24 VDC One input circuit: 15 mA: Both input circuits: 0 mA No. of inputs: 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9- 32VDC Battery charging capacity: 35.OAH INDICATOR LIGHTS AC power on: Green Battery trouble: Yellow Ground fault: Yellow Aux trouble: Yellow Output troubles (1-4): Yellow ORDERING INFORMATION 5495: Distributed Power Module ACCESSORIES SK-SCK: Seismic Compliance Kit AGENCY LISTINGS DL listed CSFM 7300-0559:123 Meets NFPA 72 requirements MEA 429-92-E Vol Xli OSHPD (CA) OSP-0065-10 For a complete listing of all comoliance approvals and certifications, please visit www.silentknight.com. Microsoft. Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensor and Honeywell are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. Ail specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-323-0103 Doc 3503951 Rev HI 11/17 5)2017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 h Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: Recert. 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation** & A Sleek Modern Aesthetics Finger Slide Switches' Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB O 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 o Universal Mounting Base cr Ceiling and Wall Mounts to 5 Backbox Types COOPER Notification EJWC~E~' Strobe, Horn Strobe, and Horn Notification Appliances Ceiling Wall Description: The Wheelocka ExcederTM Series of notification appliances feature a sleek modem design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederlM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Environmentally Friendly Low current Draw Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol - Compatible with U L "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range "Compared to competitive models "" Patented ""Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Genera! Notes: General Notes: Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971 Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32F to 120F (0C to 49C) and maximum humidity of 93% (± 2%) UL464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC UL Max Current* at Anechoic 99 dBA 24VDC 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0 21 0.282 0.125 0.159 HSC 8.0-33.0 0.082 . 0.102 0.141 0.148 0.176 .• 0.197 0.242 0.282 0.125 UL 1E l• I 24VDC 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 80330 0.073 0.083 0.087 0.139 0.163 0.186 0230 0272 0.122 0.153 HSC 80330 0.073 0087 0U8 01 01 0.186 02 02 0U2 I •E Max Current* at Anechoic 90 dBA 24VDC - 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 80330 - 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 80330 0.065 0.226 - 0.267 7770.1 2D HornRatings per UL Anechoic Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync WI Model Strobe DSM or 12/24 VDC* Mounting Candela Wheelock Power Options Supplies H 15/1575/30f75/9511101135/185 X X UMB** HSW 15/157513017519511101135/185 X X UMB* HSRC 15/30/60/75/95/115/150/177 X X UMB** HSWC 15/30160175/95/115/150/177 X X UMB** STR 1511575/30/75195/110(135/185 X X UMB* STW 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** ST\NC :11111 15/30/60/75/951115/1501177 X X UMB** HNR • X X UMB** HNRC HNW X X X UMB** X UMB HNWC 77 ME, X X UMB NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings fordBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58W x 2.19' D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and SIC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/11 Cooper Notification is Wheelock MEDCJ SAFEPATH WAVE _? ?COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDCIFWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to Iistee 'S Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V* operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division