HomeMy WebLinkAbout703 PALOMAR AIRPORT RD; ; FPC2018-0059; PermitPERMIT REPORT
caty of
Carlsbad
Print Date: 01/25/2022
Job Address: 703 PALOMAR AIRPORT RD, CARLSBAD, CA 92011-1040
Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm
Parcel #: Track #:
Valuation: $0.00 Lot #:
Occupancy Group: Project #:
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check#:
Plan Check #:
Permit No: FPC2018-0059
Status: Closed - Finaled
Applied: 02/20/2018
Issued: 03/19/2018
Finaled Close Out: 12/14/2020
Inspector:
Final Inspection:
Project Title:
Description: CARLSBAD PACIFIC CENTER -FIRE ALARM PANEL REPLACEMENT TO ACCOMODATE ELEVATOR RECALL
Applicant: FPContractor:
NOVA SECURITY NOVA SECURITY
CORY HILL 8779 COTTONWOOD AVE, # STE 103
8779 COTTONWOOD AVE, # STE 103 SANTEE, CA 92071457
SANTEE, CA 92071-4457 (619) 448-3007
(619) 448-3007
FEE AMOUNT
FIRE TI Fire Alarm System $601.00
Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
Ff'~ZDI~-Oc)G~
Carlsbad Pacific Center
703 Palomar Airport Road
Carlsbad, CA 92011
Fire Alarm Submittal
Submitted By;
NV A
SECURITY
8779 Cottonwood Ave. Suite 103
Santee, CA 92071
619-448-3007
Cory Hill
Cont. Lic C-10 # 802053
Carlsbad Pacific Center
Fire Alarm Submittal
Equipment List
Nova Security and Lead Installers certifications
Certified Fire/Life Safety Card
Contractors License: C10-802053
Potter PFC-6000 Software Certification
Description Model Manufacture CSFM#
Fire Alarm Panel IPA-100 POTTER 7165-0328:0500
Micro Input Module PAD100-MIM POTTER 7165-0328:0500
Relay Module PAD100-RM POTTER 7165-0328:0500
Photoelectric Smoke Sensor PAD100-PD POTTER 7272-0328:0504
Manual Pull Station P32-1T-LP POTTER 7150-0328:0156
Selectable Candela Strobe & Horn/Strobe HS-24 POTTER 7135-0328:0225
(E)POTTER I PA-1 00
The Symbol of Protection Fire Alarm Control Panel
Features
127 addresses available on this analog addressable system
Additional system capacity achieved via multi-point SLC modules
99 software zones
NFPA 72 Compliant Smoke Sensitivity Test Built-In
System Operates as Class A or Class B for SLC, P-Link and NACs
5 Amp Power Supply, Expandable to 310 amps
2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each,
ideal for manual release and abort
Strobe Synchronization and System Wide Sync for Potter/AMSECO®,
Gentex®,Cooper Wheelock® and System Sensor® strobes
Dedicated Alarm, Supervisory and Trouble Relays
4,000 Event History Buffer
Cabinet will house up to 18 A batteries'
Optional two line DACT with UD-1000 that can report General, Zone or
Point Information
Built in IP Communicator
Ethernet Port for Programming and Network Connectivity
E-Mail System Status, Reports and Event Information
Product includes 5 year warranty
LISTED
UUKL Compliance accomplished when using DRy-SO with the Space
Age Electronics GL8
Description Technical Specifications
The IPA- 100 is an analog/addressable releasing fire alarm system with a
total system capacity of 127 addresses. Additional capacity on the system
is achieved using multi-point SLC modules. The control panel utilizes
the exclusive Potter protocol that includes a complete line of sensors and
modules. Each SLC may be comprised of any combination of smoke
sensor, heat detectors or modules and allows for a total of 50 ohms of
impedance and may use any wire compliant with the National Electrical
Code (NEC).
The IPA- 100 has a 5 Amp power supply with two Notification Appliance
Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at
3 Amps each and the I/Os are rated at I Amp each. Each output is regulated
and power limited. In addition, each output is uniquely programmable and
may be configured for steady signal, strobe synchronization, constant
power, door holder power, or releasing. The strobe synchronization
includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock
and with the exclusive Quadrasync each output may have a unique brand
and all strobes will flash together. The I/Os are designed for inputs such as
manual release stations and abort switches that will not require polling and
react nearly instantaneously.
The IPA-100 is listed for releasing of fire suppression systems. The
software allows cross zones, counting zones, and timers for suppression.
The system is capable of multiple release outputs across multiple hazards.
In addition, the PSN- 1000 may be used to extend releasing capability.
The NACs may be expanded using the PSN-1000 series intelligent power
supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional
input circuits and the IPA-100 will support up to 31 power supplies. The
system will synchronize the strobes system wide. In addition, the PSN-
I000E has space to allow the installation of up to six loop expansion cards.
The cards mount on a stacker bracket that allows access to all SLC circuit
connections.
Dimensions 16"W x 17"H x 3 7/8"D
AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 3.0
Amps @ 240 VAC 50/60 HZ
Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window
'Standby Current- 130 mA
Alarm Current-200 mA
5 Amps power for NACs, I/O, and P-Link
Battery 3 Amps per NAC, regulated
I Amp per I/O circuit, regulated
Battery Charger range 8-55 Ah
Battery Charger voltage 27.3 VDC
P-Link maximum current of I Amp
Temperature and 32° to 120° (0°C to 49°C) with a maximum
Humidity Range humidity of 93% non-condensing.
NFPA 12, 12A, 13, 15, 16, 17, 17A, 70,
72, 750, and 2001
ANSI/UL 864 - Local (L), Remote Sta-
tion (RS), Central Station (CS), Propriety
(PPU), Auxiliary (AUX).Type of Service:
Automatic (A), Manual (M) Water flow Standards (WF) Sprinkler Supervisory (SS) Type of
Signaling: Digital Alarm Communicator
(DAC), March Time (March), Non Coded
(NC), Reverse Polarity (Rev Pot), Other
Technologies (OT)
IBC 2000, 2003, 2006, 2009, 2012
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com
8830101 -REVB • 05/17 PAGE 10F4
(E)POTTER I PA-1 00
The Symbol of Protection Fire Alarm Control Panel
SLC Loop Accessories
The control panel may be connected with up to 127 addressable devices or modules in any combination. The SLC is not restricted by any special wire
requirements and may be wired with any wire that complies with the NEC.
SLC Loop Devices
Device Description
PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot.
PADI -PI-ffl Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent
obscuration and a fixed temperature 135° Fahrenheit heat detector.
PAD100-HD Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F.
PAD100-DUCTR Addressable Duct Smoke Detector with Form C Relay.
PAD 100-DUCT Addressable Duct Smoke Detector.
PAD100-613 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors.
PAD 100-4B 4" round base that may be mounted to an electrical box and wired for connection to the above sensors.
PAD 100-lB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop.
PAD 100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125 VAC.
PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured-for local, group and all call.
PADIOO-CD Addressable CO gas detector.
PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure.
Modules
Device Description
PADIOO-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure.
PAD100-PSSA Single Action Addressable Pull Station.
PAD loo-PSDA Dual Action Addressable Pull Station.
PAD 100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box.
PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode.
PADIOO-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2
amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs.
PADIOO-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel.
PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system.
PAD 100-fM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop.
PADIOO-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at I25VAC.
PAD 100-LED Module provides a single addressable LED that is controlled by the control panel.
PADlOO-SM Speaker Module provides switching for two audio channels.
PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box.
PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised.
PAD 100-OROI One Relay One Input Module provides one fbrm C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC.
Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com
8830101-REVB • 05/17 PAGE 2OF4
® POTT ER
The Symbol of Protection
IPA-1 00
Fire Alarm Control Panel
SLC Features
The Potter protocol is a digital protocol with a proven design for
reliability and noise immunity. The system does not require special
cable or conductors for connection of the Signaling Line Circuit
as long as the cable is compliant with NFPA 70 and NFPA 72.
The system allows for Class A or Class B installations as well as
"T-Taps", with a max wiring distance of 10,000 Ft.
Sensor Features
The sensors through the fire alarm control panel provide a real
time status as to the condition of the system. The smoke detector
sensitivity, heat detector temperature level and drift compensation
are all programmable options. The system also allows for a day/night
mode where the panel automatically adjusts the sensitivity depending
on the time of day. To assist in the reduction of false alarms, the
smoke detectors also have a maintenance warning that sends a trouble
signal when a detector is dirty to the point that it can no longer
maintain the programmed sensitivity.
User Interface
The fire alarm control panel has a 2 x 16 LCD display to provide
information to the system status. The keypad has navigation keys
to allow manipulation of the Menu on board the panel. The panel is
shipped standard with the following LEDs:
AC Power - Green
Alarm - Red
Earth Fault - Amber
Supervisory - Amber
Silenced - Amber
Trouble - Amber
Pre-Release - Amber
Release - Red
The common buttons include a Silence, Reset, Acknowledge, and
Drill. All of the buttons are accessible once the locked door is
opened.
P-Link
The IPA-100 has a proprietary communication protocol that
communicates through a RS-485 connection to field devices. Up
to 64 devices may be connected to a single P-Link connection. The
P-Link includes the communication terminals and regulated 24 VDC
connection for the field devices. The field devices may be any of the
following:
PADIOO-SLCE-Analog/Addressable loop expansion module
RA-6075R —2 x 16 LCD annunciator with a key pad in a locked
metal enclosure.
RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked
metal enclosure. Flush mount version available.
LED-16(F) - 16 LED annunciator with common indicators in a
locked metal enclosure. Flush mount version available.
PSN-1000(E) - 10 amp, remote intelligent power supply with
6 NACs, 2 I/Os and a P-Link repeater. This panel is listed in
conjunction with the IPA-100 as releasing circuits.
CA-6500 - Class A convertor that converts the SLC, NACs and
P-Link connection
UD-1000 - UL listed, Dual line telephone alarm communicator
DRV-50 - LED driver expander, used to connect up to 50 LEDs in a
graphic display
FCB-1000 - Fire communication bridge, provides remote mounting
of the Ethernet connection
FIB-bOO - Fiber interface module, used to extend P-Link to multi-
mode fiber (2 required)
RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0
amps 24VDC/125AC
SPG-1000 - Serial parallel gateway, allows for the connection to a
serial or parallel printer
The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the
stacker bracket or ordered with the optional rack mount enclosure.
MC-1000 Multi-Connect allows up to sixty-three IPA series panels to
share a single reporting technology.
AE-2 - Two card expansion cabinet
AE-8 - Eight card expansion cabinet
AE-14 -Fourteen card expansion cabinet
Ethernet/I.P. Connection
The IPA-100 is shipped standard with an Ethernet connection.
This connection is the programming port and may be connected
to a building Wide Area Network (WAN) or Local Area Network
(LAN). Once connected to the Internet, the panel may be selectively
programmed to e-mail alarm conditions, trouble conditions,
supervisory conditions, test, Event History and detector status. An
e-mail may be sent to the panel and the panel will e-mail the event
history, detector status, configuration file or server status to an
authorized E-mail account. In addition, reminders may be set to send
an e-mail for service, testing or other conditions.
In addition, the Ethernet connection is UL listed as an IP
communicator. The IP communicator is listed to report to the UL
listed Sur-Gard III IP receiver. The IP communicator replaces the
traditional less reliable alarm communicator transmitter that utilized
telephone lines. The IP communicator is an active method of
connection and communication to the monitoring station.
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com
8830101-REVB • 05/17 PAGE 3OF4
(P)POTTER I PA-1 00
The Symbol of Protection Fire Alarm Control Panel
Dimensions
r ot
TOP DEPTH =3.75"
1°
oj
DOOR = 16.07"
BACKBOX = 15.77 DEPTH = 3.84"
0
LEFT SIDE RIGHT SIDE
BOTTOM
COG #593-1
Ordering Information
Model Description I Stock No.
IPA-100 I Fire Alarm Releasing Control Panel 1 31992715
Compatible Releasing Devices
Note: For releasing applications please order the Potter EOLD
(3005012) for circuits connected to a releasing solenoid or actuator.
Brand Description
Skinner 732 18BN4UNLVNOC 112CZ
732 12BN4TNLVN0C322C2
Victaulic 753-E Series
Mini Max MX 123 & MX200 wl 8876677 & 889323
Viking 11591, 11601, 11602, 13843,& 13844
TLX PA0036
Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830101-REVB • 05/17 PAGE 4OF4
(E)POTTER \
PAD100-MIM
The Symbol of Protection Micro Input Module
Features
One Class B contact monitoring input
Small size allows mounting in most electrical boxes
SLC Class A, Class X & Class B
6" Pigtail wiring connections
Product includes a 5 year warranty
1 2 4 8i24
6
10 )H
®POTTER
PAD 100-MIM (SLC Module)
I-SLC IN I
11
LISTED
Description
The PADIOO-MJM is used to monitor the status of an initiating
device(s) that contain a normally open set of dry contacts. The module
is enclosed in a plastic case to protect against inadvertent shorts and
ground faults. The case can be mounted using a single screw. The
PAD 100-MIM has a status indicator LED to indicate communication
and alarm condition. In normal condition, the LED flashes when the
device is being polled by the control panel. When the input is activated,
the LED will flash at a fast rate.
Application
The micro input module (PAD IOO-MTM) is compatible with Potter's
IPA series addressable fire alarm control panels. Generally the
PADIOO-MIM is used to monitor pull stations and other devices
where the module is installed in an electrical box or enclosure behind
the device being monitored.
Technical Specifications
Operating Voltage 24.OV
Max SLC Standby (2001iA' Current
Max SLC Alarm 200lJA Current
IDC Input Circuit Class B Wiring
Max Wiring Resistance 100 of DC
Max Wiring 1 iF Capacitance of DC
EOL Resistor 5.1K1
Operating Temperature
Range 32 to 120°F (0 to 49°C)
Operating Humidity
Range
0 to 93% (non-condensing)
Max no. of Module Per 127 units Loop
Dimensions 1.75" (44.5mm)L)< 1.36"
(34.5mm)Wx .43" (llmm)D
Mounting Options 2-1/2" (64mm) deep single-gang box
Shipping Weight 0.3 lbs
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
8830079- REV A • 03/16 PAGE 1 OF 2
(P)POTTER PADI OO-MIM
The Symbol of Protection Micro Input Module
Setting the Address
Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the front of the PAD 100-MIM. Before
connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device:
I. Power to the device is removed.
Field wiring is correctly installed.
Field wiring has no open or short circuits.
Wiring Diagram
Fig I
FROM FACP OR PREVIOUS.
DEVICE AND TO NEXT DEV
TO NORMALLY OPEN
MONITORED DEVICE
5.1K OHM REQUIRED
Part #3005013
Ordering Information
Model Description Stock No.
PAD 100-MIM I Micro Input Module 3992700
Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830079- REVA • 03/16 PAGE 2 OF 2
(E)POTTER
The Symbol of Protection
Features
One (1) Form C relay contact
SLC Class A, Class X & Class B
Mounts in a standard 4" or double gang box
Wiring terminals accessible when mounted in box
All wiring terminals accept 22 to I2AWG
Product includes a 5 year warranty
Description
The PADIOO-RM uses one (1) SLC loop address to provide one (1)
Form C relay contact. The module mounts on either a 4" square or
double gang box. The PAD IOO-RM includes one red LED to indicate
the module's status. In normal condition, the LED flashes when the
device is being polled by the control panel.
Application
The PAD100-.RM is compatible with Potter's IPA series addressable
fire alarm control panels. The PADIOO-RM is an interface module
providing one (I) Form C relay contact.
Setting the Address
Each addressable SLC device must be assigned an address. The
address is set using the DIP switch located on the PAD 100-RM. The
PAD 100-RM uses a single device address to identify relay contacts.
Before connecting a device to the SLC loop, take the following
precautions to prevent potential damage to the panel or device:
Power to the device is removed.
Field wiring is correctly installed.
Field wiring has no open or short circuits.
PAD1 00-RM
Relay Module
-
/1
LISTED
Technical Specifications
Operating Voltage 24.OV
Max SLC Standby 24011 Current
Max SLC Alarm
Current 1 1 401iA
Relay Contacts 2A @30VDC, 0.5A @l25VAC
Operating Temperature
Range 32 to 120°F (0 to 49°C)
Operating Humidity
Range 0 to 93% (non-condensing)
Max no. of Module Per 127 units Loop
Dimensions 4.17" (106mm)L x 4.17"
(106mm)W x 1.14" (29mm)D
Mounting Options Standard 4" Square or
Double Gang Box
Shipping Weight 0.6 lbs
Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
8830084 -REVA • 03/16 PAGE 1 OF 2
(DPOTTER
The Symbol of Protection
PADI 00-RM
Relay Module
Installation Using Compatible Electrical Box
Fig 1
Wiring Diagram
PADIOO-RM Relay Circuit
Fig 2
FROM FACPOR
PREVIOUS MODULE
TO NEXT MODULE
Oi 0 Ci
f o
C ONE (1) FORM C
RELAY .Y1
LN, CONTACTS : : 0 0
0 0
0 0
0 0
PO TI
00
PADI
ci o Gi
It is possible that the internal relay in the PAD 100-RM may be shipped in the non-normal I activated state. To ensure that the internal relay is set to the
normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output.
Ordering Information
Model Description Stock No.
PAD100-RM Relay Module 3992705
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830084- REVA • 03/16 PAGE 2 OF 2
IPA-60•8870022 -REV A • 06/16
Built-in SLC Current Draw Worksheet (PAD Protocol)
Device Type Qty Standby
'mA' '
Total
Standby
(mA)
Alarm
'mA' ' '
Total
Alarm
(mA)
Photo detector (PAD 100-PD) .300 .300
Fixed heat detector (PAD 100-HD) .300 .300
CO detector (PAD 100-CD) .300 .300
Combination photo/heat detector (PAD 100-PHD) .300 .300
Duct detector (PAD 100-DUCT) .300 .300
Duct detector w/relay (PAD I 00-DUCTR) *Notes 4 & 5 .500 .500
Duct detector remote test switch (PAD 100-DRTS) 10.0 15.0
Mini input module (PAD IOO-MIM) .200 .200
Speaker module (PAD-100-SM) .240 .240
Pull station module single action (PAD 100-PSSA) .200 .200
Pull station module dual action (PAD 100-PSDA) .200 .200
Relay module (PAD 100-RM) .240 .240
Notification Appliance Circuit (PAD 100-NAC ) *Note 2 .200 .200
Twin relay-twin input module (PAD 100-TRTI) .240 .240
Double input module (PAD 100-DIM) .240 .240
One relay-one input module (PAD 100-OROI) .240 .240
Zone module (PAD 100-ZM) *Note 1 .240 .240
Remote LED module (PAD 100-LED) .240 .240
Remote LED w/Key (PAD 100-LEDK) .200 .200
Single input module (PAD 100-SIM) .240 .240
Addressable sounder base (PAD 100-SB) *Note 3 .200 .200
Addressable relay base (PAD 100-RB) .200 .200
Isolator base (PAD] 00-113).150 .150
Isolator module (PADIOO-IM) .150 .150
SLC alarm LED Current n/a n/a n/a 36.0
SLC Standby
Current
SLC Alarm
Current
* Note I: PAD 100-ZM requires 24VDC power source. Standby Current = 15.0 mA. Alarm Current = 60.0 mA.
* Note 2: PAD 100-NAC requires 24VDC power source. Standby Current = 3.0 mA. Alarm Current = 8.0 mA.
* Note 3: PAD 100-SB requires 24VDC power source. Standby Current = 4.0 mA. Alarm Current = 30.0 mA.
* Note 4: PAD 100-DUCTR requires 24VDC power source. Standby Current = 30.0 mA. Alarm Current = 60.0 mA.
* Note 5: When connecting the MS-RA/MSKA/P/R power source, Standby Current = 45.0 mA. Alarm Current = 90 mA.
2-10
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7165-0328:0500 Page 1 of 1
CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)
LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States
Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999
Email: biIIwpottersignal.com
DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow
and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU),
proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction
Manual for details. System components (CSFM Listing 7305-0328:0200):
PAD100-DIM Dual Input Module
PAD1 00-LED Addressable LED Module
PAD 100-OROI One Relay-One Input Module
PAD 100-RM Relay Module
PAD 100-SIM Single Input Module
PAD 100 TRTI Two Relay-Two Input Module
PAD 100-ZM Zone Module
PAD 100-IM lolator Module
PAD 100- NAC Notification Appliance Circuit Module
PAD 100-SM Speaker Module
PAD 100-MIM Micro Input Module
PAD 100-LEDK LED Key Switch Module
PAD 100-DRTS Duct Remote Test Switch
PAD 100-SLCE127 Point SLC Expander
MC-1000 Multi-Connect
PAD 100-DUCTR
AE-2 Enclosure
RATING: 24 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model designation, rating and UL label.
APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally
compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual
for details.
03-07-2017 dcc
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2017 Listing Expires June 30, 2018
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division
(E)POTTER PADI 00-PD
The Symbol of Protection Photoelectric Smoke Sensor
Features
Low profile, less than 2 inches with the base
Wide selectable sensitivity range of 1.0 to 3.70/o/foot
Sensor communicates sensitivity to control panel
UL listed smoke calibration and sensitivity
Optional locking tab to prevent unwanted removal
Simple DIP switch address setting, no programming tool
required
LED alarm indicator
Product includes a 5 year warranty
LISTED
Description
The Photoelectric Smoke Sensor is a listed Analog Addressable smoke
sensor compatible with fire alarm control panels that utilize the Potter
Addressable Device (PAD) protocol. The PAD 100-PD is a low profile
smoke sensor with a wide sensitivity range. The sensor and base (not
included) are made of a durable plastic in an off-white color to blend
in with the ceiling.
The PAD 100-PD has a sensitivity range of 1.0 to 3.7 % per foot and
is UL. The PAD 100-PD features drift compensation and has built in
dirty detector warning as well as. The PADIOO-PD and the control
panel communicate over a proven and robust digital communication
path and the system analyzes the information at the particular device.
The total polling speed is less than five (5) seconds, well under the UL
requirements.
The sensor is compatible with any of the PAD series sensor bases and
simply twists on. The PAD 100-PD is addressed using DIP switches
in the rear of the sensor and can be easily programmed in the field
without special tools.
Setting the Address
Each addressable device on the SLC loop must have a unique address
from I to 127 to function properly. The address is set using DIP
switches.
Before connecting a device to the SLC loop, take the following
precautions to prevent potential damage to SLC or device. Verify the
following:
Power to the device is removed
Field wiring is correctly installed.
Field wiring has no open or short circuits.
Technical Specifications
Operating Voltage 24 VDC
Alarm indicator 1 LED
Alarm set-point range 1.0 to 3.7 %/ft 3.6-12 %/m
Installation temperature 32to 120°F/ 0to49°C range
Operating relative 0% to 93% (Non-condensing) humidity range
Start-up time Max. 1 sec.
Maximum number of 127 addresses per loop
Maximum number of
lighted indicators in 30
alarm per loop.
Color Eggshell White
Weight (without base) lOig (3.56oz)
Dimensions (without Height: 1.35 in (34mm)
base) Diameter: 3.93 in (100 mm)
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
8830108- REVA • 03/16 PAGE 1 OF 2
OPOTTER
The Symbol of Protection
PADI 00-PD
Photoelectric Smoke Sensor
Air Velocity Ratings
The PAD 100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute.
The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD 100-PD will operate even
though the LED may not illuminate.
Operation
The PAD 100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel.
The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is
in an active status. The polling LED can be turned off if desired for less conspicuous operation.
The PAD100-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The
sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector.
Sensor Sensitivity
The PAD 100-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor
compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned
or replaced.
The PAD 100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to
the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs.
NOTE: As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors
have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service.
Spacing
The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing,
placement and special applications.
Compatible Bases
All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box.
Device Description Stock No.
PAD100-4DB 4" Standard Base 3992731
PAD 100-61313 6" Standard Base 3992732
PAD 100-lB 6" base with an isolator module included. 3992730
PAD 100-RB 6" base with one Form-C relay contact. 2A@ 30VDC, 0.5A @ 125VAC 3992728
PAD 100-SB 6" base with sounder module included. Sound pattern is provided from external source. 13992729
Ordering Information
Model Description Stock No.
PADI 00-PD Photoelectric Smoke Sensor 3992733
Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com
8830108-REVA • 03/16 PAGE 2OF2
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7272-0328:0504' Page 1 of 1
CATEGORY: 7272'-- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC
LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States
Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999
Email: billwpottersignaI.com
DESIGN: Models PAD100-PD, PAD100-DD and PAD100-PHD photoelectric smoke detector heads.
Model PAD 100-PHD has an intergral heat detector. Refer to Listee's data sheet for detailed
product description and operational considerations.
RATING: 24Vdc
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, electrical rating, and UL label.
APPROVAL: Models PADIOO-PD and PAD100-PHD are listed as photoelectric smoke detector heads for
use with listee's detector base Models PAD100-4DB, PADI00-6DB, PADIOO-RB,
PADI 00-SB (CSFM#7300-0328:502) and Model PAD1 00-I B (CSFM#7300-0328:501). Model
PAD IOO-DD is listed as a photoelectric smoke detector head for use with Model
PAD 100-DUCT (CSFM#3248-0328:0505). Refer to listee's Installation Instruction Manual for
details.
06-21-2017 dcc
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 07, 2017 Listing Expires' June 30, 2018
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division
i'ouER.
DIE-CAST METAL
PULL STATION SERIES
The Symbol of Protection MANUAL PULL STATIONS
UL and cUL Listed, FM Approved, CSFM Listed, MEA
IE1i!Ij1 Approved, ADA Compliant
Single or Dual Action
PULL
j
PULL : Switch
Gold plated SPST contacts
Optional auxiliary contacts
_______
______L
• Mounts on standard single gangbox
Surface backboxes available
/ High-gloss red enamel finish
Glass breakrod
,
• Made in the U.S.A. UM
Description
The Potter Pull Station Series offers a complete line of die-cast pull
stations for a variety of applications focusing mainly on fire alarm
systems. The pull stations are available in single or dual action
models. All of the pull stations have a 10-amp snap action switch and
a dedicated terminal block for the ease of wire connections. All of
the metal is completely coated to inhibit corrosion and provide for a
uniform and quality finish.
The standard models have a hex key reset, however a key reset is also
available. The models are available with shallow and deep surface
mount back boxes and as a weatherproof version.
Operation
The Potter single action series of pull stations operate by pulling
the white operating handle straight down and the handle will lock
into place. The dual action stations require the lifting of the front
cover and then pulling the white operating handle straight down. The
stations are reset by opening the front and placing the handle in the
normal position.
Ordering Information
Engineering Specifications
The contractor shall furnish and install the Potter series of pull
stations as indicated. The pull station shall be die cast construction
with a "T" type pull handle that is ADA compliant. Single action pull
stations shall be a P32-IT. Dual action pull stations shall be the Potter
P32-1T-LP. Any manual pull station installed in an outdoor or wet
location shall be a RMS-1T-WP weather proof unit. The contact shall
be a single pole, single throw switch rated at I amp 30V DC/I 25V
AC. The device shall have a terminal block for ease of wiring. Once
activated, the pull station shall be reset by opening the front cover.
Opening of the cover in a normal state shall initiate an alarm.
Specifications
Switch Rating: I Amp @ 30 VDC
l0 Amps @ 125 VAC
Pull Station Dimensions: 4-3/4" H x 3-1/4" W x 7/8" D
Color: Red with raised white letters, white pull bar with raised red letters
For special application manual stations see bulletin 98910014.
For explosion proof manual stations see bulletin #8880014.
Type Model Number Stock Number Contact Type
Single Action
P32-IT 1000447 SPST
RMS-2T 1000477 DPST
RMS-6T 1000478 DPDT
RMS-IT-KL 1000451 SPST
RMS-IT-KO 1000450 SPST, key operated, no pull
Weather Proof RMS-1T-WP 1000401
SPST Dual Action P32-1T-LP 1000476
Weather Proof Dual Action RIvIS- 1 T-WP-LP 1000403
Accessories Notes
Dual Action RMS-LP 1000480 Converts single action to dual action
Back Box P32-BB 1000444 Surface mount back box
Back Box P32-DBB 1000445 Deep surface mount back box
Glass Rods RMS-GB 1000470 Replacement glass rods (10 per pkg)
Potter Electric Signal Co., LLC• St. Louis, MO - Cust Service: 866-240-1870 • Tech Support: 866-956-1211 Canada 888-882-1833 www.pottersignal.com
PRINTED IN USA MKT. 48900097 - REV L PAGE 1 OF I
9/10
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL -
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7150-0328:0156 Page 1 of I
CATEGORY: 7150-- FIRE ALARM PULL BOXES
LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States
Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999
Email: BillWpottersignal.com
DESIGN: Models P32-1T (alien or key, no push bar) and P32-IT-LP (key lock or alien key) noncoded
manual pull stations. Refer to listee's data sheet for additional detailed product description
and operational considerations.
RATING: 10 Amp. @ 120 VAC, 30VDC
INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a
manner acceptable to the authority having jurisdiction.
MARKING: Listees name, model number, electrical rating and UL label.
APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control
units.
These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with
California amendments.
XLF: 7150-1039:0101
*Rev 8-3-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
?VC operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2017 Listing Expires.' June 30, 2018
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division
(E)POTTER S-24 & HS-24
The Symbol of Protection Selectable Candela Strobe & Horn/Strobes
Features
24VDC units have field selectable candela options of 15, 30, 60,
75& 110
Super-Slide® Bracket - Ease of Supervision Testing
HE
Checkmate® - Instant Voltage Verification
Synchronize strobe and/or horn with AVSM Control Module
Prewire entire system, install mounting bracket, then install signals . •
_• r
Documented lower installation and operating costs ''. _1•
Switch selection for high or low dBA
Switch for chime, whoop, mechanical and 2400Hz tone 1.
Tamperproof re-entrant style grill
Switch for continuous or temporal 3 tone (not available on
whoop tone)
Silence audible while visual appliance will remain flashing (for
use in accepted jurisdictions) \._.. '.
Faceplate available in red or off-white .-
LISTED
S3247
Description Technical Specifications
The L' 'I Series is a low profile strobe and horn/
strobe combination that offers dependable audible and visual
alarms and the absolute lowest current available. The S-24
& HS-24 Series 24VDC offers tamperproof field selectable
candela options of 15, 30, 60, 75, and 110 candela. The
Strobe and Horn/Strobe offers a continuous or sync temporal
three in 2400Hz and mechanical tone, a chime and whoop
tone. All tones are easy for the professional to change in the
field by the use of switches. The S-24 & HS-24 Series has a
minimal operating current and has a minimum flash rate of
1Hz regardless of input voltage.
This Series is shipped with a standard 4" metal mounting
plate which incorporates the popular Super-Slide® feature
that allows the installer to easily test for supervision. The
product also features a locking mechanism which secures the
product to the bracket without any screws showing.
The S-24/HS-24 also features the patented Checkmate® -
Instant Voltage Verification feature which allows the installer
to check the voltage drop draw and match it to the blueprint.
The S-24 & HS-24 Series appliances are ANSI/UL 464 and
ANSI/UL 1971, listed for use with fire protective systems
and are warranted for three years from date of purchase.
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com
8830054-REV C 6/17 PAGE 1 OF 4
Single or Double gang. 4"
Mounting Options square box, and AVBB surface
mount back box
Terminals Screw-Clamp Type
Wire Gauge 18— 12AWG
Operating Temp 32°F - 120°F (0° - 49°C)
Height - 5"
Dimensions Width —4.5"
Depth —2.5"
Shipping Weight 1.05 lbs
TONE
SWITCH POSITION
3 4 5
Mechanical Temporal 3 ON ON ON
Mechanical Continuous OFF ON ON
2400 Hz Temporal 3 ON OFF ON
2400 Hz Continuous OFF OFF ON
Chime Temporal 3 ON ON OFF
Chime Continuous OFF ON OFF
Whoop ON OFF OFF
Whoop OFF OFF OFF
NOTE:
Switch Positions iThe and 2 in the OFF position to select
isolated horn and strobe power inputs
Switch Position 6 ON = HIGH dBA
Switch Position 6 OFF = LOW dBA
Candela Selection
(E)POTTER S-24 & HS-24
The Symbol of Protection Selectable Candela Strobe & Horn/Strobes
Switch Locations
Super Slide® Mounting Bracket
Allows the installer to pre-wire the system, test for system
supervision, remove the signal head until occupancy, switch
out signals without changing mounting brackets and has
locking edge connector for snap-in-place installation.
Potter Electric Signal Company, LLC St. •Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
5830054-REV C 6/17 PAGE 2 OF 4
(E)POTTER S-24 & HS-24
The Symbol of Protection Selectable Candela Strobe & Horn/Strobes
S-24 24 VDC Selectable Candela, Low
Profile Evacuation Strobe
Model Nominal Candela (ANSI/UL Part Number Number Voltage 1971)
S-24WR 4890010 24 VDC 15,30,60,75, 110
S-24WW 4890011 24 VDC 15, 30, 60, 75, 110
HS-24 24 VDC Selectable Candela,
Low Profile Evacuation Strobe
Candela (ANSI! Reverberant dBA at 10 In Anechoic Room at Model Number Part Number Nominal Voltage UL 1971) ft, perANSI/UL 464 lOft
HS-24WR 4890030 24 VDC 15, 30, 60, 75, 110 62-82 100
HS-24WW 4890031 24 VDC 15, 30, 60, 75, 110 62-82 100
S-24 & HS 24 Strobe Current Ratings
24 VDC (16 - 33 Volts)
Candela 24 VDC UL Max
15 c 30 mA 42 mA
30 c 35 mA 58 mA
60 c 66 mA 97 mA
75 c 80 mA 116 mA
110 c 103 mA 161 mA
S-24 & HS-24 Horn Ratings
Model Designations:
W = Wall mount
R = Red Faceplate W=White Faceplate
All units are available in plain (no lettering)
Plain units are non-returnable.
"ALERT" bezel available for order.
"AGENT" bezel available for order.
Horn Mode
Horn Decibel Levels Horn Current Ratings
Minimum SPL at 10 ft, per
ANSI/UL 464 (HIGH)
Minimum SPL at 10 ft,
per ANSI/UL 464 (LOW)
Regulated 24 VDC Max
Operating @ High Setting (mA)
Temp 3 (2400 Hz) 78 dBA 71* dBA 28 mA
Temp 3 (Mechanical) 76 dBA 70* dBA 25 mA
Temp 3 (Chime) 70* dBA 66* dBA 15 mA
Continuous (2400 Hz) 81 dBA 74* dBA 28 mA
Continuous (Mechanical) 80 dBA 72* dBA 25 mA
Continuous (Chime) 70* dBA 66* dBA 15 mA
Whoop 82 dBA 69* dBA 56 mA
NOTES:
For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave
Rectified]) power see installation manual.
Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products.
The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While
the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode.
* Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level
required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA
setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode).
Potter Electric Signal Company, LLC • St Louis, MO • Phone: 800-325-3936 www.pottersignal.com
8830054-REV C 6/17 PAGE 3 OF 4
I
Signal I
5- H+ H- I Ii
END OF LINE
RESISTOR I
I UL Listed
Control
Panel
Supervised
I Signal Circuit
UL Listed
Control Signal Panel I + S+ S- H+ -
Supervised II I
Signal Circuit
Signal Signal
S- H+ H- S+ S+ 5- E
END OF LINE
RESISTOR
END OF LINE
RESISTOR
(E)POTTER S-24 & HS-24
The Symbol of Protection Selectable Candela Strobe & Horn/Strobes
S-24 & HS-24 Series Wiring Diagram
Notes:
All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits.
However, use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn, and/or mute the horn.
FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (8830050) AND/OR AVSM
CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND
MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC TECHNICAL SUPPORT AT 1-866-956-1211
Architect & Engineering Specifications
The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be
listed by Underwriters Laboratories, Inc. per ANSI/UL 1971 and/or ANSI/UL 464. The notification appliance shall also be listed with
Factory Mutual Listing Service (FM) and the California State Fire Marshal (CSFM).
The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 24VDC as
measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the
visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or
temporal tone output with the temporal signal having the ability to be synchronized.
Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at
the fire alarm control panel.
The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power
input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit.
The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting
bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double
workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full
wave rectified power for 24VDC models.
The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be
capable of mounting to a surface back box.
Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com
8830054-REV C 6/17 PAGE 4 OF 4
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE 0
LISTING No. 7135-0328:0225 Page 1 of 1
CATEGORY: 7135 --AUDIBLE DEVICES
LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States
Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999
Email: billwpottersignal.com
DESIGN: Model EH24 horn and Model HS24 and HS24-177 horn strobes. May be followed by -W
(wall) and -W or -R (white or red) or-P plain. Refer to listee's data sheet for additional product
description and operational considerations.
RATING: Electrical: 24 VDC
HS24 Wall: 15cd, 30cd, 60cd, 75cd, 110cd (selectable)
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listees name, model number, electrical ratings and UL label.
APPROVAL: Listed as horn and horn/strobes for use with separately listed compatible fire alarm control
units. For indoor use only. The audible in Model EH24 and H524 may produce distinctive
tones including: mechanical, 2400Hz and chime tones in continuous and temporal 3 settings
as well as a whoop tone in either a high or low dBA setting.
XLF: 7135-0569:0122
03-24-15 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification cf any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2017 Listing Expires' June 30, 2018
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division