HomeMy WebLinkAbout703 PALOMAR AIRPORT RD; ; FPC2018-0059; PermitPERMIT REPORT caty of Carlsbad Print Date: 01/25/2022 Job Address: 703 PALOMAR AIRPORT RD, CARLSBAD, CA 92011-1040 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check #: Permit No: FPC2018-0059 Status: Closed - Finaled Applied: 02/20/2018 Issued: 03/19/2018 Finaled Close Out: 12/14/2020 Inspector: Final Inspection: Project Title: Description: CARLSBAD PACIFIC CENTER -FIRE ALARM PANEL REPLACEMENT TO ACCOMODATE ELEVATOR RECALL Applicant: FPContractor: NOVA SECURITY NOVA SECURITY CORY HILL 8779 COTTONWOOD AVE, # STE 103 8779 COTTONWOOD AVE, # STE 103 SANTEE, CA 92071457 SANTEE, CA 92071-4457 (619) 448-3007 (619) 448-3007 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Ff'~ZDI~-Oc)G~ Carlsbad Pacific Center 703 Palomar Airport Road Carlsbad, CA 92011 Fire Alarm Submittal Submitted By; NV A SECURITY 8779 Cottonwood Ave. Suite 103 Santee, CA 92071 619-448-3007 Cory Hill Cont. Lic C-10 # 802053 Carlsbad Pacific Center Fire Alarm Submittal Equipment List Nova Security and Lead Installers certifications Certified Fire/Life Safety Card Contractors License: C10-802053 Potter PFC-6000 Software Certification Description Model Manufacture CSFM# Fire Alarm Panel IPA-100 POTTER 7165-0328:0500 Micro Input Module PAD100-MIM POTTER 7165-0328:0500 Relay Module PAD100-RM POTTER 7165-0328:0500 Photoelectric Smoke Sensor PAD100-PD POTTER 7272-0328:0504 Manual Pull Station P32-1T-LP POTTER 7150-0328:0156 Selectable Candela Strobe & Horn/Strobe HS-24 POTTER 7135-0328:0225 (E)POTTER I PA-1 00 The Symbol of Protection Fire Alarm Control Panel Features 127 addresses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class A or Class B for SLC, P-Link and NACs 5 Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®,Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event History Buffer Cabinet will house up to 18 A batteries' Optional two line DACT with UD-1000 that can report General, Zone or Point Information Built in IP Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information Product includes 5 year warranty LISTED UUKL Compliance accomplished when using DRy-SO with the Space Age Electronics GL8 Description Technical Specifications The IPA- 100 is an analog/addressable releasing fire alarm system with a total system capacity of 127 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The IPA- 100 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at I Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA-100 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN- 1000 may be used to extend releasing capability. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the IPA-100 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- I000E has space to allow the installation of up to six loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Dimensions 16"W x 17"H x 3 7/8"D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 3.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window 'Standby Current- 130 mA Alarm Current-200 mA 5 Amps power for NACs, I/O, and P-Link Battery 3 Amps per NAC, regulated I Amp per I/O circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of I Amp Temperature and 32° to 120° (0°C to 49°C) with a maximum Humidity Range humidity of 93% non-condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Sta- tion (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Automatic (A), Manual (M) Water flow Standards (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pot), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101 -REVB • 05/17 PAGE 10F4 (E)POTTER I PA-1 00 The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 127 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PADI -PI-ffl Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector. PAD100-HD Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F. PAD100-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD 100-DUCT Addressable Duct Smoke Detector. PAD100-613 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD 100-4B 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD 100-lB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD 100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125 VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured-for local, group and all call. PADIOO-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. Modules Device Description PADIOO-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD loo-PSDA Dual Action Addressable Pull Station. PAD 100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PADIOO-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PADIOO-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-fM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PADIOO-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at I25VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PADlOO-SM Speaker Module provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD 100-OROI One Relay One Input Module provides one fbrm C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101-REVB • 05/17 PAGE 2OF4 ® POTT ER The Symbol of Protection IPA-1 00 Fire Alarm Control Panel SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green Alarm - Red Earth Fault - Amber Supervisory - Amber Silenced - Amber Trouble - Amber Pre-Release - Amber Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The IPA-100 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: PADIOO-SLCE-Analog/Addressable loop expansion module RA-6075R —2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) - 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 I/Os and a P-Link repeater. This panel is listed in conjunction with the IPA-100 as releasing circuits. CA-6500 - Class A convertor that converts the SLC, NACs and P-Link connection UD-1000 - UL listed, Dual line telephone alarm communicator DRV-50 - LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 - Fire communication bridge, provides remote mounting of the Ethernet connection FIB-bOO - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 - Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three IPA series panels to share a single reporting technology. AE-2 - Two card expansion cabinet AE-8 - Eight card expansion cabinet AE-14 -Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA-100 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101-REVB • 05/17 PAGE 3OF4 (P)POTTER I PA-1 00 The Symbol of Protection Fire Alarm Control Panel Dimensions r ot TOP DEPTH =3.75" 1° oj DOOR = 16.07" BACKBOX = 15.77 DEPTH = 3.84" 0 LEFT SIDE RIGHT SIDE BOTTOM COG #593-1 Ordering Information Model Description I Stock No. IPA-100 I Fire Alarm Releasing Control Panel 1 31992715 Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 732 18BN4UNLVNOC 112CZ 732 12BN4TNLVN0C322C2 Victaulic 753-E Series Mini Max MX 123 & MX200 wl 8876677 & 889323 Viking 11591, 11601, 11602, 13843,& 13844 TLX PA0036 Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVB • 05/17 PAGE 4OF4 (E)POTTER \ PAD100-MIM The Symbol of Protection Micro Input Module Features One Class B contact monitoring input Small size allows mounting in most electrical boxes SLC Class A, Class X & Class B 6" Pigtail wiring connections Product includes a 5 year warranty 1 2 4 8i24 6 10 )H ®POTTER PAD 100-MIM (SLC Module) I-SLC IN I 11 LISTED Description The PADIOO-MJM is used to monitor the status of an initiating device(s) that contain a normally open set of dry contacts. The module is enclosed in a plastic case to protect against inadvertent shorts and ground faults. The case can be mounted using a single screw. The PAD 100-MIM has a status indicator LED to indicate communication and alarm condition. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The micro input module (PAD IOO-MTM) is compatible with Potter's IPA series addressable fire alarm control panels. Generally the PADIOO-MIM is used to monitor pull stations and other devices where the module is installed in an electrical box or enclosure behind the device being monitored. Technical Specifications Operating Voltage 24.OV Max SLC Standby (2001iA' Current Max SLC Alarm 200lJA Current IDC Input Circuit Class B Wiring Max Wiring Resistance 100 of DC Max Wiring 1 iF Capacitance of DC EOL Resistor 5.1K1 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 1.75" (44.5mm)L)< 1.36" (34.5mm)Wx .43" (llmm)D Mounting Options 2-1/2" (64mm) deep single-gang box Shipping Weight 0.3 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830079- REV A • 03/16 PAGE 1 OF 2 (P)POTTER PADI OO-MIM The Symbol of Protection Micro Input Module Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the front of the PAD 100-MIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: I. Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Wiring Diagram Fig I FROM FACP OR PREVIOUS. DEVICE AND TO NEXT DEV TO NORMALLY OPEN MONITORED DEVICE 5.1K OHM REQUIRED Part #3005013 Ordering Information Model Description Stock No. PAD 100-MIM I Micro Input Module 3992700 Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830079- REVA • 03/16 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features One (1) Form C relay contact SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to I2AWG Product includes a 5 year warranty Description The PADIOO-RM uses one (1) SLC loop address to provide one (1) Form C relay contact. The module mounts on either a 4" square or double gang box. The PAD IOO-RM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PAD100-.RM is compatible with Potter's IPA series addressable fire alarm control panels. The PADIOO-RM is an interface module providing one (I) Form C relay contact. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 100-RM. The PAD 100-RM uses a single device address to identify relay contacts. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. PAD1 00-RM Relay Module - /1 LISTED Technical Specifications Operating Voltage 24.OV Max SLC Standby 24011 Current Max SLC Alarm Current 1 1 401iA Relay Contacts 2A @30VDC, 0.5A @l25VAC Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830084 -REVA • 03/16 PAGE 1 OF 2 (DPOTTER The Symbol of Protection PADI 00-RM Relay Module Installation Using Compatible Electrical Box Fig 1 Wiring Diagram PADIOO-RM Relay Circuit Fig 2 FROM FACPOR PREVIOUS MODULE TO NEXT MODULE Oi 0 Ci f o C ONE (1) FORM C RELAY .Y1 LN, CONTACTS : : 0 0 0 0 0 0 0 0 PO TI 00 PADI ci o Gi It is possible that the internal relay in the PAD 100-RM may be shipped in the non-normal I activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description Stock No. PAD100-RM Relay Module 3992705 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830084- REVA • 03/16 PAGE 2 OF 2 IPA-60•8870022 -REV A • 06/16 Built-in SLC Current Draw Worksheet (PAD Protocol) Device Type Qty Standby 'mA' ' Total Standby (mA) Alarm 'mA' ' ' Total Alarm (mA) Photo detector (PAD 100-PD) .300 .300 Fixed heat detector (PAD 100-HD) .300 .300 CO detector (PAD 100-CD) .300 .300 Combination photo/heat detector (PAD 100-PHD) .300 .300 Duct detector (PAD 100-DUCT) .300 .300 Duct detector w/relay (PAD I 00-DUCTR) *Notes 4 & 5 .500 .500 Duct detector remote test switch (PAD 100-DRTS) 10.0 15.0 Mini input module (PAD IOO-MIM) .200 .200 Speaker module (PAD-100-SM) .240 .240 Pull station module single action (PAD 100-PSSA) .200 .200 Pull station module dual action (PAD 100-PSDA) .200 .200 Relay module (PAD 100-RM) .240 .240 Notification Appliance Circuit (PAD 100-NAC ) *Note 2 .200 .200 Twin relay-twin input module (PAD 100-TRTI) .240 .240 Double input module (PAD 100-DIM) .240 .240 One relay-one input module (PAD 100-OROI) .240 .240 Zone module (PAD 100-ZM) *Note 1 .240 .240 Remote LED module (PAD 100-LED) .240 .240 Remote LED w/Key (PAD 100-LEDK) .200 .200 Single input module (PAD 100-SIM) .240 .240 Addressable sounder base (PAD 100-SB) *Note 3 .200 .200 Addressable relay base (PAD 100-RB) .200 .200 Isolator base (PAD] 00-113).150 .150 Isolator module (PADIOO-IM) .150 .150 SLC alarm LED Current n/a n/a n/a 36.0 SLC Standby Current SLC Alarm Current * Note I: PAD 100-ZM requires 24VDC power source. Standby Current = 15.0 mA. Alarm Current = 60.0 mA. * Note 2: PAD 100-NAC requires 24VDC power source. Standby Current = 3.0 mA. Alarm Current = 8.0 mA. * Note 3: PAD 100-SB requires 24VDC power source. Standby Current = 4.0 mA. Alarm Current = 30.0 mA. * Note 4: PAD 100-DUCTR requires 24VDC power source. Standby Current = 30.0 mA. Alarm Current = 60.0 mA. * Note 5: When connecting the MS-RA/MSKA/P/R power source, Standby Current = 45.0 mA. Alarm Current = 90 mA. 2-10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0500 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: biIIwpottersignal.com DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components (CSFM Listing 7305-0328:0200): PAD100-DIM Dual Input Module PAD1 00-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 03-07-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER PADI 00-PD The Symbol of Protection Photoelectric Smoke Sensor Features Low profile, less than 2 inches with the base Wide selectable sensitivity range of 1.0 to 3.70/o/foot Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting, no programming tool required LED alarm indicator Product includes a 5 year warranty LISTED Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD 100-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD 100-PD has a sensitivity range of 1.0 to 3.7 % per foot and is UL. The PAD 100-PD features drift compensation and has built in dirty detector warning as well as. The PADIOO-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD 100-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from I to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: Power to the device is removed Field wiring is correctly installed. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24 VDC Alarm indicator 1 LED Alarm set-point range 1.0 to 3.7 %/ft 3.6-12 %/m Installation temperature 32to 120°F/ 0to49°C range Operating relative 0% to 93% (Non-condensing) humidity range Start-up time Max. 1 sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) lOig (3.56oz) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108- REVA • 03/16 PAGE 1 OF 2 OPOTTER The Symbol of Protection PADI 00-PD Photoelectric Smoke Sensor Air Velocity Ratings The PAD 100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD 100-PD will operate even though the LED may not illuminate. Operation The PAD 100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD100-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD 100-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD 100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE: As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 PAD 100-61313 6" Standard Base 3992732 PAD 100-lB 6" base with an isolator module included. 3992730 PAD 100-RB 6" base with one Form-C relay contact. 2A@ 30VDC, 0.5A @ 125VAC 3992728 PAD 100-SB 6" base with sounder module included. Sound pattern is provided from external source. 13992729 Ordering Information Model Description Stock No. PADI 00-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830108-REVA • 03/16 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0328:0504' Page 1 of 1 CATEGORY: 7272'-- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignaI.com DESIGN: Models PAD100-PD, PAD100-DD and PAD100-PHD photoelectric smoke detector heads. Model PAD 100-PHD has an intergral heat detector. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models PADIOO-PD and PAD100-PHD are listed as photoelectric smoke detector heads for use with listee's detector base Models PAD100-4DB, PADI00-6DB, PADIOO-RB, PADI 00-SB (CSFM#7300-0328:502) and Model PAD1 00-I B (CSFM#7300-0328:501). Model PAD IOO-DD is listed as a photoelectric smoke detector head for use with Model PAD 100-DUCT (CSFM#3248-0328:0505). Refer to listee's Installation Instruction Manual for details. 06-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 07, 2017 Listing Expires' June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division i'ouER. DIE-CAST METAL PULL STATION SERIES The Symbol of Protection MANUAL PULL STATIONS UL and cUL Listed, FM Approved, CSFM Listed, MEA IE1i!Ij1 Approved, ADA Compliant Single or Dual Action PULL j PULL : Switch Gold plated SPST contacts Optional auxiliary contacts _______ ______L • Mounts on standard single gangbox Surface backboxes available / High-gloss red enamel finish Glass breakrod , • Made in the U.S.A. UM Description The Potter Pull Station Series offers a complete line of die-cast pull stations for a variety of applications focusing mainly on fire alarm systems. The pull stations are available in single or dual action models. All of the pull stations have a 10-amp snap action switch and a dedicated terminal block for the ease of wire connections. All of the metal is completely coated to inhibit corrosion and provide for a uniform and quality finish. The standard models have a hex key reset, however a key reset is also available. The models are available with shallow and deep surface mount back boxes and as a weatherproof version. Operation The Potter single action series of pull stations operate by pulling the white operating handle straight down and the handle will lock into place. The dual action stations require the lifting of the front cover and then pulling the white operating handle straight down. The stations are reset by opening the front and placing the handle in the normal position. Ordering Information Engineering Specifications The contractor shall furnish and install the Potter series of pull stations as indicated. The pull station shall be die cast construction with a "T" type pull handle that is ADA compliant. Single action pull stations shall be a P32-IT. Dual action pull stations shall be the Potter P32-1T-LP. Any manual pull station installed in an outdoor or wet location shall be a RMS-1T-WP weather proof unit. The contact shall be a single pole, single throw switch rated at I amp 30V DC/I 25V AC. The device shall have a terminal block for ease of wiring. Once activated, the pull station shall be reset by opening the front cover. Opening of the cover in a normal state shall initiate an alarm. Specifications Switch Rating: I Amp @ 30 VDC l0 Amps @ 125 VAC Pull Station Dimensions: 4-3/4" H x 3-1/4" W x 7/8" D Color: Red with raised white letters, white pull bar with raised red letters For special application manual stations see bulletin 98910014. For explosion proof manual stations see bulletin #8880014. Type Model Number Stock Number Contact Type Single Action P32-IT 1000447 SPST RMS-2T 1000477 DPST RMS-6T 1000478 DPDT RMS-IT-KL 1000451 SPST RMS-IT-KO 1000450 SPST, key operated, no pull Weather Proof RMS-1T-WP 1000401 SPST Dual Action P32-1T-LP 1000476 Weather Proof Dual Action RIvIS- 1 T-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods (10 per pkg) Potter Electric Signal Co., LLC• St. Louis, MO - Cust Service: 866-240-1870 • Tech Support: 866-956-1211 Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MKT. 48900097 - REV L PAGE 1 OF I 9/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0328:0156 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Models P32-1T (alien or key, no push bar) and P32-IT-LP (key lock or alien key) noncoded manual pull stations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10 Amp. @ 120 VAC, 30VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1039:0101 *Rev 8-3-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ?VC operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires.' June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER S-24 & HS-24 The Symbol of Protection Selectable Candela Strobe & Horn/Strobes Features 24VDC units have field selectable candela options of 15, 30, 60, 75& 110 Super-Slide® Bracket - Ease of Supervision Testing HE Checkmate® - Instant Voltage Verification Synchronize strobe and/or horn with AVSM Control Module Prewire entire system, install mounting bracket, then install signals . • _• r Documented lower installation and operating costs ''. _1• Switch selection for high or low dBA Switch for chime, whoop, mechanical and 2400Hz tone 1. Tamperproof re-entrant style grill Switch for continuous or temporal 3 tone (not available on whoop tone) Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) \._.. '. Faceplate available in red or off-white .- LISTED S3247 Description Technical Specifications The L' 'I Series is a low profile strobe and horn/ strobe combination that offers dependable audible and visual alarms and the absolute lowest current available. The S-24 & HS-24 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The Strobe and Horn/Strobe offers a continuous or sync temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to change in the field by the use of switches. The S-24 & HS-24 Series has a minimal operating current and has a minimum flash rate of 1Hz regardless of input voltage. This Series is shipped with a standard 4" metal mounting plate which incorporates the popular Super-Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The S-24/HS-24 also features the patented Checkmate® - Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The S-24 & HS-24 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use with fire protective systems and are warranted for three years from date of purchase. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830054-REV C 6/17 PAGE 1 OF 4 Single or Double gang. 4" Mounting Options square box, and AVBB surface mount back box Terminals Screw-Clamp Type Wire Gauge 18— 12AWG Operating Temp 32°F - 120°F (0° - 49°C) Height - 5" Dimensions Width —4.5" Depth —2.5" Shipping Weight 1.05 lbs TONE SWITCH POSITION 3 4 5 Mechanical Temporal 3 ON ON ON Mechanical Continuous OFF ON ON 2400 Hz Temporal 3 ON OFF ON 2400 Hz Continuous OFF OFF ON Chime Temporal 3 ON ON OFF Chime Continuous OFF ON OFF Whoop ON OFF OFF Whoop OFF OFF OFF NOTE: Switch Positions iThe and 2 in the OFF position to select isolated horn and strobe power inputs Switch Position 6 ON = HIGH dBA Switch Position 6 OFF = LOW dBA Candela Selection (E)POTTER S-24 & HS-24 The Symbol of Protection Selectable Candela Strobe & Horn/Strobes Switch Locations Super Slide® Mounting Bracket Allows the installer to pre-wire the system, test for system supervision, remove the signal head until occupancy, switch out signals without changing mounting brackets and has locking edge connector for snap-in-place installation. Potter Electric Signal Company, LLC St. •Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 5830054-REV C 6/17 PAGE 2 OF 4 (E)POTTER S-24 & HS-24 The Symbol of Protection Selectable Candela Strobe & Horn/Strobes S-24 24 VDC Selectable Candela, Low Profile Evacuation Strobe Model Nominal Candela (ANSI/UL Part Number Number Voltage 1971) S-24WR 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15, 30, 60, 75, 110 HS-24 24 VDC Selectable Candela, Low Profile Evacuation Strobe Candela (ANSI! Reverberant dBA at 10 In Anechoic Room at Model Number Part Number Nominal Voltage UL 1971) ft, perANSI/UL 464 lOft HS-24WR 4890030 24 VDC 15, 30, 60, 75, 110 62-82 100 HS-24WW 4890031 24 VDC 15, 30, 60, 75, 110 62-82 100 S-24 & HS 24 Strobe Current Ratings 24 VDC (16 - 33 Volts) Candela 24 VDC UL Max 15 c 30 mA 42 mA 30 c 35 mA 58 mA 60 c 66 mA 97 mA 75 c 80 mA 116 mA 110 c 103 mA 161 mA S-24 & HS-24 Horn Ratings Model Designations: W = Wall mount R = Red Faceplate W=White Faceplate All units are available in plain (no lettering) Plain units are non-returnable. "ALERT" bezel available for order. "AGENT" bezel available for order. Horn Mode Horn Decibel Levels Horn Current Ratings Minimum SPL at 10 ft, per ANSI/UL 464 (HIGH) Minimum SPL at 10 ft, per ANSI/UL 464 (LOW) Regulated 24 VDC Max Operating @ High Setting (mA) Temp 3 (2400 Hz) 78 dBA 71* dBA 28 mA Temp 3 (Mechanical) 76 dBA 70* dBA 25 mA Temp 3 (Chime) 70* dBA 66* dBA 15 mA Continuous (2400 Hz) 81 dBA 74* dBA 28 mA Continuous (Mechanical) 80 dBA 72* dBA 25 mA Continuous (Chime) 70* dBA 66* dBA 15 mA Whoop 82 dBA 69* dBA 56 mA NOTES: For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power see installation manual. Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products. The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Potter Electric Signal Company, LLC • St Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830054-REV C 6/17 PAGE 3 OF 4 I Signal I 5- H+ H- I Ii END OF LINE RESISTOR I I UL Listed Control Panel Supervised I Signal Circuit UL Listed Control Signal Panel I + S+ S- H+ - Supervised II I Signal Circuit Signal Signal S- H+ H- S+ S+ 5- E END OF LINE RESISTOR END OF LINE RESISTOR (E)POTTER S-24 & HS-24 The Symbol of Protection Selectable Candela Strobe & Horn/Strobes S-24 & HS-24 Series Wiring Diagram Notes: All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn, and/or mute the horn. FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC TECHNICAL SUPPORT AT 1-866-956-1211 Architect & Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories, Inc. per ANSI/UL 1971 and/or ANSI/UL 464. The notification appliance shall also be listed with Factory Mutual Listing Service (FM) and the California State Fire Marshal (CSFM). The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830054-REV C 6/17 PAGE 4 OF 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7135-0328:0225 Page 1 of 1 CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Model EH24 horn and Model HS24 and HS24-177 horn strobes. May be followed by -W (wall) and -W or -R (white or red) or-P plain. Refer to listee's data sheet for additional product description and operational considerations. RATING: Electrical: 24 VDC HS24 Wall: 15cd, 30cd, 60cd, 75cd, 110cd (selectable) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings and UL label. APPROVAL: Listed as horn and horn/strobes for use with separately listed compatible fire alarm control units. For indoor use only. The audible in Model EH24 and H524 may produce distinctive tones including: mechanical, 2400Hz and chime tones in continuous and temporal 3 settings as well as a whoop tone in either a high or low dBA setting. XLF: 7135-0569:0122 03-24-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification cf any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires' June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division