Loading...
HomeMy WebLinkAbout6219 EL CAMINO REAL; ; FPC2018-0419; Permit(Jiity of PERMIT REPORT Carlsbad Print Date: 02/03/2022 Permit No: FPC2018-0419 Job Address: 6219 EL CAMINO REAL, CARLSBAD, CA 92009-1604 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2131001400 Track #: Applied: 12/24/2018 Valuation: $0.00 Lot #: Issued: 01/23/2019 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: SAFC CARLSBAD INC -FIRE ALARM TI Applicant: FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS JOHNSON CONTROLS SECURITY SOLUTIONS LLC LLC - DONOTUSE MALCOLM DCOSTA 3870 MURPHY CANYON RD, # 140 3870 MURPHY CANYON RD, # 160 SAN DIEGO, CA 92123-4403 SAN DIEGO, CA 92123-4403 (561) 226-8210 (619) 805-5300 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov r—or 21-D 19 — 0+101 DF-52185:C • B-150 LCD-80F 80-Character Liquid Crystal Display Remote Fire Annunciators General The LCD-80F is a compact, cost-effective, 80-character, back- lit LCD remote Fire Annunciator for use with the Fire-Lite MS- 9200UD Series and MS-9600 Series Fire Alarm Control Pan- els (FACP5). The LCD-80F displays complete system point status information and includes control switches for remote control of critical system functions. Up to 32 LCD-80Fs may be connected onto the EIA-485 termi- nal port of each FACP. The LCD-80F requires no program- ming, which saves time during system commissioning. Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. No programming necessary - LCD-80F connects to the terminal port (TB7) Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time-and-date display field. Aesthetically pleasing design. May be powered from the host FACP or by remote power supply (requires 24 VDC). Up to 32 LCD-80F annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. Local piezo sounder with alarm and trouble resound. Semi-flush mounts to 2.188" (5.556 cm) minimum deep, three-gang electrical box (Fire-Lite PN 10103) or three-gan- gable electrical switchbox. Surface-mounts to Fire-Lite PN SBB-3 surface backbox. Operation The LCD-80F annunciator provides the FACP with point annunciation with full display text on an 80-character LCD dis- play. The LCD-80F also provides an array of LEDs to indicate system status, and includes control switches for remote control of critical system functions. The LCD-80F provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the LCD-80F use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communications (two in and two return); and two for the 24 VDC regulated power. Dip switches control local functions such as: piezo dis- able, control switches/key-switch disable, transmit/receive mode. 8 FIreLITeALarms by Honeywell LCD-80F Installation The LCD-80F can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box (Fire-Lite PN 10103) or three-gangable electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount appli- cations. Product Line Information LCD-80F: 80 character, backlit, LCD Fire Annunciator with control switches for remote control of system functions, and key-switch lock. LCD-80FC: ULC-listed version; see DF-60576 for details. 10103: Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S232 MEA Listed: 72-01-E CSFM: 7120-1574:179 FM Approved NOTE: For ULC-listed version, see DF-60576. DF-52185:C • 05/17/2010 - Pagel of 2 LCD-80F TERMINAL MODE WIRING EXAMPLE Up to 6,000 ft. (1828.8 m) between EACH DEVlCEin the EIA-485 loop —.,, IrLCD-80F LCD-8Terminal Mode ------- \ ElA-485 . I ---- ) • .......... (2 wires) .. 411 EEI 24 VDC (2-wires) - LCD-80F u/ Up to 6,000 ft. (1828.8 m) back from last device to end of ElA-48: loop Terminal Mode ElA-485 return (2-wires) Addressable Fire Alarm Control Panel NOTE: EIA-485: Maximum of 6,000 feet (1828.8 m) cable length from FACP to LCD-80F annunciators, 6,000 feet cable length between each LCD-80F and 6,000 feet from the last LCD-80F back to the FACP. Circuit is power-limited. Up to 32 LCD-80F annunciators may be used on the EIA-485 circuit. When multiple LCD-80Fs are used, the FACP will require additional power supplies (refer to panel documentation). Between each LCD-80F annunciator are four wires: a twisted-shielded pair for data communications and a pair for 24 VDC power. The return circuit only requires two wires (twisted) for data communication supervision, wired from the last LCD-80F annunciator on the loop. fl Mounting To Backbox(es) FIRE ALARM ANNUNCIATOR '_ - ~ - , -, , :- ,, -0 FIRE-LITE ALARMS, SYSTEMS ALL NORMAL V7 11:06A 032001 II The LCD-80F annunciators can be semi-flush mounted in a three-gang electrical box with a minimum depth of 2.188' (5.556 cm) (Fire-Lite PN 10103). The LCD-80F annunciators can be mounted in three-gangable electrical switchboxes connected together. NOTE: Alternately, LCD-80F annunciators can be mounted to the SBB-3 surface backbox for surface-mount applications. NOTE: This annunciator may not fit easily into a standard 3-gang electrical box if locking clamps are used to secure wiring entering the rear or side knockouts. Only use the TOP or BOTTOM knock- outs to bring wiring into a standard 3-gang electrical box. 5.813' (14.764 cm) wide x 4.0" 10.16 Cm) high x minimum 2.188" (5.556 cm) deep, three-gang electrical box (Fire-Lite PN 10103, shown above). Fire-Lite® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. ______________ We cannot cover all specific applications or anticipate all requirements. W11lN9MANVMC1flINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52185:C • 05/17/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0190 Page 1 of I CATEGORY: 7120 - ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Model LCD-80F remote fire annunciator. Unit is a compact 80-character, backlit LCD fire annunciator. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. NOTE: XLF: 7120-0028:209 *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SECTION2 FIRE ALARM CABLE PART NUMBER I AWG I CONDUCTOR SHIELDED! I OVERALL UNSHIELDED DIAMETER I CONDUCTOR COLOR JACKET COLOR VOLTAGE RATING WEIGHT (Is)/Unit MARKINGS TEMP PUT UPS BLACK, RED. RED 300v 1&0 AOl 494449 700cl -o LIGHT BLUE, LBS 41C18AWG REEL YELLOW TYPE FPLP! CMP (UL) BLACK RED, 26.0 QMP!FPLP 6/4 BROW, BLUE LBS (UL) 16 AWG WHITE 360 AOl 493496 BLACK/RED, LBS IPR16AWG 19AWG IPR19AWG LIGHT BLUE! TYPE FPLP,,' YELLOW GIVIP ( L) RED AOl 493498 1000 IPRIBAWG REEL PRI9AWG TYPE FPLP! (j) CMP(UL) ADT 493498 1 PR1&AWG [18.0 5 BS REEL 1PR19AWG TYPE FPLP! L[ CMP (UL) 2.22 DON'T SEE IT? CALL 1888-423-8947 ORDERS PHONE 1-888-423-8947, FAX 847.797-3853 2,23 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-2075:0100 Page 1 of I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: Paige Electric Companyll6o Springfield Road, Union, NJ 07083 Contact: Cindy Regner (908) 687-7810 Fax (908) 687-8860 Email: cregnerpaigeelectric.com DESIGN: Types FPL, FPLP and FPLR power limited fire protective signaling cables. Insulation - PVC compound AlphaGary Smokeguard 4010, Synergistics 1349-1028 FRD, 1360-1021-PID, PP, HDPE or LDPE. Shields - (Optional) All metal or Aluminum Polyester tape. Braid - (Optional) All metal. Jacket - PVC compound AlphaGary Smokeguard 11 6920, Gitto Global GA-8705-03, AlphaGary GW2038, Synergistics 1690-1060, 1604-1007 FR, 1100-1092 FRD, JAP61A or 1410-1011 FRD, Solef 31008-0003. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, Type FPL, FPLP or FPLR, rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. NOTE: Formally 7161-1677:100 XLF: 7161-1509:0100 mt09-09-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division