Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3420 CAMINO DE LOS COCHES; ; FPC2017-0259; Permit
$Cityof PERMIT REPORT Carlsbad Print Date: 02/03/2022 Permit No: FPC2017-0259 Job Address: 3420 CAMINO DE LOS COCKS, CARLSBAD, CA 92009-8927 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: Track #: Applied: 09/05/2017 Valuation: $0.00 Lot #: Issued: 09/13/2017 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: STAGECOACH - BACKFLOW REPLACEMENT (UG SM) Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MATJORGENSEN 1075W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE Underground Piping with upto4 Hyds/Risers $733.00 Total Fees: $733.00 Total Payments To Date: $733.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 2-o i 02S9 San Diego Branch Office .000004 I cosco 4990 Greencraig Lane ..S.I... .. ..• i San Diego, CA 92123 Fire Protection (858) 444-2000 fax: 444-2056 CALic.: C-16#577621 www.coscofire.com MATERIAL SUBMITTAL & HYDRAULIC CALCULATIONS Date: 9/1/17 STAGECOACH BACKFLOW REPLACEMENT 3420 CAMINO DE LOS COCHES CARLSBAD, CA 92009 JOB # 10.CD 5779 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: M. JORGENSEN Los Angeles 0 San Francisco • Orange • Fresno • San Diego • Seattle ZURN Model 3750A WILKINS Reduced Pressure Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and back- pressure of contaminated water into the potable water supply. The Model 375DA shall provide protection where a potential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Unless otherwise noted, applies to sizes 2 1/2" thru 10") ASSE® Listed 1047 UL® Classified AWWA Compliant C550 CSA® Certified B64.4 (4" & 6") C-UL® Classified FM® Approved 'NYC MEA 218-01-M VOL3 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California Meets the requirements of NSF/ANSI 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backf low Assembly 3/40 Model 975XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Springs Stainless steel, 300 series Sensing line Stainless steel, braided hose Features Sizes: 2 1/2", 3", 4", 6", 8", 10" NSF/ANS1 61 Options (Suffixes can be combined) - with OS & Y gate valves (standard) L - less shut-off valves (flanged body connections) L LM - less water meter - with remote reading meter El - with gpm meter (standard) CFM - with cu ft/min meter G - with groove end gate valves FG - with flanged inlet gate connection and grooved outlet gate connection MS - with Integral Relief Valve Monitor Switch P1 - with Post Indicator Gate Valve GF - withflanged inletconnection and grooved outlet connection BG - with grooved end butterfly valves with integral monitor switches (2 1/2" - 10') L —509 - with AWWA C509 gate valves Accessories Air gap (Model AG) J Repair kit (rubber only) Thermal expansion tank (Model XT) OS & Y Gate valve tamper switch (OSY-40) Eli QT-SET Quick Test Fitting Set Attention: Relief valve discharge Model 375DA (flange body) and port: Model 375ADA 2 1/2" -6" -2.75 sq. in. (grooved body) have different lay lengths. 8"- 10" -3.69 sq. in. Model 375DAG SHOWN BELOW Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 Dimensions & Weights (do not include pkg.) DIMENSION (approximate) WEIGHT MODEL 375DA SIZE in.mm A in. I mm A WITH BUTTERFLY VALVES in. I mm B LESS GATE VALVES in. mm C in. mm D in. mm E OS&Y OPEN in. I mm E OS&Y CLOSED in. mm B WITH BUTTERFLY VALVES in. I mm F in. mm G in. I mm LESS SHUT- OFF VALVES lbs. k OS&Y GATE VALVES FLANGED lbs. I kg OS&Y GATE VALVES GROOVED lbs. kg BUTTERFLY VALVES GROOVED lbs. I kg 21/2 65 31 787 28 711 157/8 403 71/4 184 9 229 173/4 1451 153/8 391 81/4 1 210 91/2 241 83/8 1213 75 134 1851 84 167 76 147 1 67 3 80 32 813 281/2 724 157/8 403 71/4 184 9 229 201/4 514 17 432 81/2 216 91/2 241 83/8 213 78 35 208 94 160 73 130 59 4 100 375/8 L956 328/9 83E 191/2 495 8 203 9 229 22 1/2 572 .81/4 464 9 229 ii 279 91/4 235 116 53 306 139 292 132 200 91 6 150 443/4 1137 375/8 956 231/2 597 10 254 101/2 267 301/2 775 241/4 616 101/4 260 123/8 314 91/4 235 194 88 494 224 468 212 312 142 8 20C 0 3/4 154: 537/1 136! 173/4 959 11 279 151/2 394 37 940 281/2 724 12 305 153/8 391 163/4 426 382 173 858 389 810 367 556 252 10 250 633/4 1619 577/8 14711 373/4 959 ii 279 151/2 3941455 11159134'4(4 883 13 330 153/8 391 163/4 4211 412 187 1230 558 1164 528 800 1363 Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. J Date: 1/17 Document No. BF-375DA Patent No. 5, 913, 331 Product No. Model 375DA Page 1 of 2 3000 4000 Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2' 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 I] Flow Characteristics MODEL 375DA 21/2-,3" & 4" (STANDARD & METRIC) FLOW RATES (us) 0.0 12.6 25.2 37.9 20 _____________________ 9 15 2 I ____4__•____ -= uI I .III iII 11111 /J•] '] 1 Lii iii!iIIY zl 'J1l 1 i1[4 I I.! E 0 Rated Flow (established by approval agencies) 50.5 800 252.4 S 0 1000 2000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30' (762mm) above adequate drains with sufficient side clearance for test- ing and maintenance. The installation shall be made so that no part of the unit can be submerged. PROTECTIVE OUTDOOR INSTALLATION INDOOR INSTALLATION Specifications The Reduced Pressure Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1047, and supplied with full port OS & Y gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the S line. The Reduced Pressure Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 375DA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Rabies, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 i- 1`11~ I V Schedule=10/Schedule-40 - ABFII 0 Fully Listed and FM Approved Sprinkler Pipe When you specify Allied Schedule-11 O/Schedule-40 - ABFII sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 - ABFII gives you the extra quality assurance you demand. Our Sch-10 (11/4"-8") pipe and Sch-40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. > Galvanized Pipe Schedule- 10/Schedule-40 -ABFII product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications o1ASTM A-123. > Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFll". In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* > American Made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. > Specifications & Approvals Schedule-10/Schedule-40 -ABFII pipe are in compliance with the following: ASTM A-135, Type E Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture * See ABFII warranty T k.].I. NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/m Lbs/Ft; kg/m - 1.049 1.680 2.05 1 25 26.6 2.5 3.05 - 11/4 1.380 2.270 2.93 1 32 35.1 4.36 4.36 - 11/2 2.720 3.61 1 40 40.9 4.0 5.37 - 2.067 3.650 5.13 1 50 52.5 5.4 7.63 - 21/2" 2.469 5.790 7.86 1 65 62.7 8.6 11.73 - ¶ I[.IiI. NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/m Lbs/Ft; kg/m - 11/4 1.810 2.525 7.0955 32 36.6 2.7 3.75 - 1½" 1.682 2.080 3.04 5.6570 40 42.7 3.1 4.52 - 2.157 2.640 4.22 4.5827 50 54.8 3.9 6.28 - 21/2" 2.635 3.530 5.89 3.5196 65 66.9 5.3 8.77 - 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 - 4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 - 5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 - 6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 209.5 1 24.5 59.75 - CPPCOVID S L........... ---- - Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com Cl I I le d 16100 S Lathrop Ave. • 11350 Norcorn Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 A BRAND OF atkore 2011 Atkore International, Inc. All Rights Reserved. STP-S5-3-1105 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) FireLock® Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire protection systems. Vic.PlusTM Gasket System: In North America, Victaulic® offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The VicPlusTM System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. -' !!!I (I) § LPC and VdS Approved, see notes on page 4 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS I'AltNILU t-- I et S P rstem L! Ill.' I VJU L) U .11j" elllJUIfiT1a7PTll LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Woking Pressure - psi Related Working Pressure - psi Related Working Pressure - psi _EL ET 1/4-2 300 N/A N/A MT 1¼-2 300 N/A N/A 5 1/43 175 1 175 175 11/v _4 350 350 350 14-2 300 N/A N/A STF t'/4-4 N/A N/A 300 10,40 Steady 'N/A 5-8 300 300 300 EZ 4-6 3008 N/A 300 1/4-2 N/A 300 BY 1 ¼ - 2 300 300 N/A FF 11/4-4 N/A N/A 300 TF 3 - 8 N/A N/A 300 11/a_4 300 300 300 GAL-7 1¼-2 300 N/A N/A WLS 41¼-2 300 300 N/A DF DT 11/4 - 2 300 300 N/A MLT 1 ¼ - 7 300 N/A N/A XL 111/4 - 3 300 300 300 [F 1Y-4 175@ N/A 175 ME 11/n_4 300 N/A 1 3000 FM approved for service in 1 1/1 - 4" pipe. 8 UL Listed for service up to 4' pipe only. @ UL Listed for service up to 3" only. S JOB/OWNER System No. Location CONTRACTOR Submitted By Date ENGINEER Spec Sect Approved Date Para www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV-1 Ai-c—ta-ulic 10.02_i IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) Size ~Pressure Max. Work Max. End Load Allow. Pipe End Sep. f No - I Dimensions I t¼ 1.660 350 755 005 2-3/ x2¼ 275 4.50 188 1.2 32 42.4 2413 3370 1.2 70 114 148 0.5 350 990 3.00 4.75 1.88 1.2 1 1/2 1.900 0.05 40 48.3 2413 4415 1.2 2 -3Ax 2¼76 121 148 0.5 2 2.375 350 1550 0.07 3.50 5.25 1.88 1.6 50 60.3 2413 6900 1.7 2 - s/ax 2½89 133 148 0.7 21/2 2.875 350 2270 0.07 4.00 5.75 1.88 1.9 65 73.0 2413 10110 1.7 2- /xx2½ 102 146 148 .09 76.1 mm 3.000 350 2475 0.07 2-3/8x2½ 4.13 5.75 1.88 1.9 76.1 2413 11010 1.7 105 146 148 0.9 3 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 2-3/8 x2½ 118 156 148 1.0 4 4.500 350 5565 0.16 2-3/8x2½ 5.75 7.25 2.13 3.1 1 00 114.3 2413 24770 4.1 146 184 54 1.4 108.0mm 4.250 300 4255 0.16 2 - 3/8 x2½ 5.63 7.25 2.13 3.1 108.0 2068 18940 4.1 143 184 54 1.4 5 5.563 300 7290 0.16 2-½x3 6.88 9.00 2.13 4.5 125 141.3 2068 32445 4.1 175 229 54 2.0 133.0 mm 5.250 300 6495 0.16 6.63 9.00 2.13 4.5 133.0 2068 28900 4.1 2- 1/2 521/4 168 229 54 2.0 139.7 mm 5.500 300 7125 0.16 - 6.88 9,00 2.13 4.8 139.7 2068 31715 4.1 2 ½x 23%175 229 54 2.2 6 6.625 300 10340 0.16 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 -x 2 ½ 3 203 254 53 2.3 159.0mm 6.250 300 9200 0.16 2-½x2~ 7.63 10.00 2.13 5.5 159.0 2068 40955 4.1 194 254 54 2.5 165.1 mm 6.500 300 9955 0.16 2-½x3 8.15 10.00 2.13 5.5 165.1 2068 44295 4.1 207 254 54 2.5 8 8.625 300 17525 0.19 2 -5/8 x4¼ 10.50 13.14 2.63 11.3 200 219.1 2068 78000 4.8 267 334 67 5.1 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance another pipe. WARNI JG: FOR ONE TIME FIELD TEST ONLY the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. Style 005 couplings are con- sidered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar/175 psi. DIMENSIONS JUL _,.4JUL I JUL 1 'III, Rated for wet and dry sprinkler systems at 350 psi/2413 kPa for 1 ¼ - 4732 - too mm sizes and 300 psi /2068kPa for 41/4 - 8/108 - 200 mm sizes; Schedule to roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expansion, contraction or angular deflection. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.02_2 \4taulicr REV_I S IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling S STYLE 005 WITH VIC.PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) Optional: Hot dipped galvanized Gasket: Grade "E" EPDM - Type A Vic-PIus' Gasket System (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Vic-Plus- Gasket System, requiring no field lubrication for most installation conditions. Grade L" Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade °E" Type A FlushSeal® Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Standard gasket and FlushSeal gasket approved for dry pipe systems to —40°F/-40°C. Based on typical" pipe surface conditions, supplemental lubricant is recommended for services installed below O°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. www.victaulic.com - vicuic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 vicTAuLic COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. iCtaul iC REV-1 10.60_3 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLtJSTM GASKET SYSTEM (NORTH AMERICA ONLY) GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. li IIIIIIDIIIMIIIIIIUIIIIIIIIIIIIIIIIIU WCAS-697KR4 For complete contact information, visit www.victaulic.com 10.02 1538 REV I UPDATED 9/2006 ict _au lic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.02 S AL F.~W.Ll~nq - Fire Protection by Computer Design COSCO FIRE PROTECION 4990 GREENCRAIG LANE SAN DIEGO, CA 92123 (858) 444-2000 Job Name Building Location System Contract Data File 10.CD_5779 STAGECOACH BY REPLACEMENT CALC #1.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 [I: Water Supply Curve C COSCO FIRE PROTECION Page Date City Water Supply: Demand: Cl - Static Pressure : 98 Dl - Elevation : 0.433 C2 - Residual Pressure: 96 D2 - System Flow : 225.4 C2 - Residual Flow : 1396 D2 - System Pressure : 84.323 Hose ( Demand) D3 - System Demand : 225.4 Safety Margin : 13.608 150 140 130 p120 Cl R 11 E10° : 590 D: s 80 U70 R6° E5° 40 30 20 10 20t91400 600 800 1000 1200 1400 1600 1800 FLOW ( N A 1.85) Is Computer Programs by Hydratec lnc.te 111 Windham N.H. USA 03087 is Fittings Sd Summary 0 COSCO FIRE PROTECION Page 2 Date Fitting Legend Abbrev. Name 1/2 ~ 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zig Wilkins 375DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD COSCO FIRE PROTECION Page 3 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. BOR 1.0 68.1 na 225.4 BF1 0.0 71.56 na BF2 0.0 81.85 na UGI 0.0 82.1 na TEST 0.0 84.32 na The maximum velocity is 15.1 and it occurs in the pipe between nodes BOR and BFI S 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 COSCO FIRE PROTECION Page 4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 225.40 2.469 2L 8.0 6.000 68.100 Qa = 225.40 to 120.0 F 3.0 11.000 0.433 BFI 225.4 0.1778 0.0 17.000 3.023 Vel = 15.10 BF1 0.0 4.1 Zig 0.0 3.160 71.556 to 140.0 0.0 0.0 10.253 * * Fixed Loss = 10.253 BF2 225.4 0.0117 0.0 3.160 0.037 Vel = 5.48 BF2 0.0 4.1 2L 17.44 5.000 81.846 to 140.0 0.0 17.440 0.0 UG1 225.4 0.0113 0.0 22.440 0.253 Vel = 5.48 UG1 0.0 4.23 T 38.446 187.000 82.099 to 150.0 G 3.845 73.047 0.0 TEST 225.4 0.0086 4F 30.757 260.047 2.224 Vel = 5.15 0.0 225.40 84.323 K Factor= 24.55 S go Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087