Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2525 EL CAMINO REAL; 257; FPC2018-0418; Permit
PERMIT REPORT Ccity of Carlsbad. Print Date: 02/03/2022 Job Address: 2525 EL CAMINO REAL, # 257, CARLSBAD, CA 92008-1265 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1563022700 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check #: Project Title: Description: WINDSOR -FIRE ALARM TI Permit No: FPC2018-0418 Status: Closed - Finaled Applied: 12/20/2018 Issued: Finaled Close Out: 08/19/2021 Inspector: Final Inspection: Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System - $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov SimplexGrinnel! LP 3568 Ruffin Road San Diego, Califomia 92123 tq iLI P: 858-633-9100 SimplexGrinnel/ i x1gOnnneii.com Fire Detection and Alarm System Product Submittal Project: Windsor The Shoppes at Carlsbad 2525 El Camino Real Suite 257 Carlsbad, CA FPC20I8..0418 2525 EL CAMINO REAL WNDSOR - FIRE ALARM II #257 1563022700 12/20/2018 FPC20I8..0418 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douqlas.daniels(äici.com 12/20/2018 REV.#: 0 PROJECT Safer. Smarter. Tyco .TM 6- tqcci eff SirnplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 1 4009-9601 IdNAC Repeater 7300-0026:0375 2 2081-9272 6.2 AH Battery N/A 1 4098-9792 Detector Base 7300-0026:0217 1 4098-9714 Smoke Sensor 7272-0026:0218 2 4098-9755 Duct Detector 3240-0026:0241 2 2098-9806 Remote Test Station 7300-0026:0150 2 4090-9010 Relay lAM 7300-0026:0311 5 4906-9204 Strobe 7125-0026:0235 6 49SV-APPLC Speaker Strobe 7125-0026:0384 Business Information 12/20/2018 REV.#: 0 PROJECT Safer. Smarter. Tyco.TM Extended distance and current FIRI Repeated IDNAC SLC 4009 IDNAC Repeater £SimpIEx 14 UL, ULC, CSFM Listed, 0-0 FM Approved* I i*i 4009 IDNAC Repeaters provide enhanced power delivery to TrueAlert/TrueAlert ES addressable notification appliances controlled by IDNAC SLCs: Output voltage is maintained by efficient switching regulator at 29 VRMS during both AC and battery backup conditions allowing strobes to operate at lower current With lower current strobes and regulated output voltage, wiring distance can be extended 2 to 3 times that of conventional notification, appliance loading can be increased, or smaller wire gauge can be used, all resulting in installation savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions 4009 IDNAC Repeaters receives an IDNAC SLC input and provide a repeated 3 A SLC output to extend SLC distance and power: Appliance control remains with the host IDNAC control panel and Repeater operation is essentially transparent; Repeater status is communicated to the control panel for system diagnostics and also locally indicated Input SLC connection can be Class B or Class A Repeater output can be a Class A loop or a Class B output with internal connections for up to four (4) T-tapped output branches (Class A output requires 4009-9814 Class A Adapter) Operation requires one IDNAC SLC address; Repeaters can be connected as one in series, or up to five (5) in parallel AC power input is 120 VAC or 220-240 VAC, 50/60 Hz, auto-select An on-board battery charger is provided with low AC battery disconnect selectable per Repeater (required for ULC listed applications) Operation is compatible with TrueAlert ES and TrueAlert addressable notification appliances and accessories Available with platinum or red cabinet Listed to UL 864 and ULC S527 Multiple wiring options are available: Wiring options include Class B multiple branch (up to 4) output, Class A loop extension, and Class A riser to Class B branches or a Class A loop output When the Repeater is part of a Class A loop from the IDNAC SLC source panel, up to twice the distance for the loop is available; (Class A loop repeating requires 4009-9814 Class A Adapter) Class A Adapter 4009-9814: Required when extending a Class A loop or to provide a Class A local loop SLC output Operation provides short circuit isolation between input and output terminals for improved IDNAC SLC survivability TrueAlert Addressable Notification 4009 IDNAC Repeater; Power and Distance Extender IDNAC SLC 4100ES with EPS Power Supply 4009 IDNAC Repeater Extends Distance and Current of IDNAC SLC Features (Continued) Built-in battery Charger Power supply charges up to 12.7 Ali batteries for in cabinet mounting and up to 25 Ali batteries with model 4009-9801 external battery cabinet Available auxiliary output: A 200 mA, 29 VDC constant auxiliary output is available; operation is maintained during battery backup * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0375 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4009-0004-2 7/2013 irnrrrrii Repeating IDNAC SLCs. 4100ES fire alarm control panels with an EPS or EPS+ (enhanced power supply) provide individual address and control of TrueAlert and TrueAlert ES addressable notification appliances using IDNAC SLCs. When an IDNAC SLC reaches the current limit or the distance limit of the source IDNAC SLC, use of 4009 IDNAC Repeaters extends the IDNAC SLC with an additional 3 A of SLC current. With IDNAC SLCs, a constant 29 VRMS source voltage is maintained, even during battery standby, allcwing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. IIi* ir1ItT1 Three wiring configurations are available to provide a variety of system solutions: Class B branch extension, Class A loop extension, and Class A riser to Class B branch extension or Class A loop output. tort-Ma Class B branch input wiring allows T-tapped connections to up to five (5) parallel connected 4009 IDNAC Repeaters. Each Repeater has on-board output terminal connections for up to four (4) output branch circuits, and additional branch circuits can be externally T-tapped as required. (Refer to diagram on page 3 for additional details.) Class A loop extensions use a single 4009 IDNAC Repeater to extend the current and distance of a single Class A loop allowing the loop distance to be doubled. The Repeater communicates and repeats bi-directionally allowing Class A loop operation to be maintained in the event of an open circuit. This wiring connection requires use of the 4009-9814 Class A adapter. (Refer to diagram on page 4 for additional details.) Class A Riser to Class B Branches or Class A Loops. For applications requiring a combination of wiring types, a Class A riser can drive up to five (5) 4009 IDNAC Repeaters with each Repeater capable of driving either single or multiple Class B branch output(s) or a Class A loop output. In this wiring application, the Repeater does not repeat in the Class A riser loop, it is connected as an appliance with Class A in/out wiring. To create a Class A loop output, the Repeater must be equipped with a 4009-9814 Class A Adapter. (Refer to diagram on page 5 for additional details.) IL1t1 Model* Cabinet Color Description 4009-9601(BA) Platinum 4009 IDNAC Repeater with cabinet; provides a single 3 A IDNAC SLC output, 200 mA auxiliary 4009-9602(BA) Red power output, and battery charger; 120/240 VAC, 50/60 Hz input, auto-select * Add suffix BA to select 4009 IDNAC Repeaters assembled in the USA. - Aftermarket Accessories (installed on-site, select per system requirements) Model Description 4009-9814 Class A Adapter Module, mounts on repeater control lr board; required for Class A output 2975-9813 Platinum semi-flush box trim 1 /16" (37 mm) wide four corners and trim pieces for top, bottom, and sides; (will 2975-9812 Red semi-flush box trim need to be cut to fit gt009 IDNAC Repeater cabinet) External Accessories (select per system requirements) Model Description Comments 4905-9929 Remote TrueAlert Communications Isolator Refer to data sheet S4905-0001 for details 4009-9801 External Battery Cabinet for 25 Ah batteries 116 %" W x 13 1/2" H x 5 -114" D (413 mm x 343 mm x 146 mm); refer to data sheet S2081-0006 for details Battery Selection (select battery size per system requirements; two batteries are required for 24 VDC operation) Model Description Model Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9275 18 Ah Eattery, 12 VDC Requires 4009-9801 External Battery Cabinet 2081-9274 10 Ah Battery, 12 VDC 2081-9287 25 Ah Battery, 12 VDC 2081-9288 112.7Ah Battery, 12 VDC fi - S4009-0004-2 7/2013 Wiring Reference, Class B Input with Class B Branch Circuit Outputs .4. 4100ES with EPS Power Supply IDNAC SLC input Class B IDNAC SLC Class B wiring can be "T-tapped' 4009 IDNAC Repeaters Class B Branch Extensions (5 maximum) IDNAC SLC output to FIRE 31RP Class B IDNAC SLC fl FIRE Class B IDNAC SLC Wiring Notes: Up to five (5) 4009 IDNAC Repeaters can be wired in parallel as shown on this diagram. IDNAC SLC communications can be repeated only once between the source and the addressable appliance. The 4009 IDNAC Repeater extends distance and current of the input IDNAC SLC; it requires one address and consumes four (4) unit loads. + + Each 4009 IDNAC Repeater has duplicate output terminals rated for two wires each, allowing up to four (4) Class B branch circuit 1-taps to be made in the cabinet; additional 1-taps may be made in external wiring junction cabinets or boxes OSimplex 4009 IOVIAC REPEATCO Class B IDNAC SLC FIRE Class B IDNAC SLC FIRS FIRS —cyFIRS FIRS FIRE FIRS FIR! FIRS FIRS Class B IDNAC SLC Branch Circuits S4009-0004-2 7/2013 Wiring Reference, Class A Loop Extension Class A IDNAC SLC Loop with 4009 IDNAC Repeater Extending Loop Range and Power 4009 IDNAC Repeater Requires optional 4009-9814 Class A Adapter Module set for Loop mode <- Class A loop secondary direction D 0 0 -Class A loop primary direction I Class A loop secondary diection 41 DOES with EPS Power Supply, requires optional 41:10-6103 Dual Class A IDNAC Isolator (DCAI) Notes Only one 4009 IDNAC Repeater can be wired in a Class A loop. (IDNAC SLC communications can be repeated only once between the source and the addressable appliance.) The 4009 IDNAC Repeater extends distance and current of the Class A IDNAC SLC loop; it requires one address and consumes four (4) unit loads. Uncer normal operating conditions (no open circuit wiring), appliances 1 through 4 are powered by the 4100ES EPS Power Supply and appliances 5 through 9 are powered from the 4009 IDNAC Repeater. Under open circuit conditions, an open circuit in the panel side of the primary path will result in the 4100ES EPS Power Supply powering appliances 5 through 9 and the 4009 IDNAC Repeater will receive IDNAC SLC input from the return path and then power appliances 1 through 4, or as many as remain connected. 4 S4009-0004-2 7/2013 IDNAC SLC input Class A Loop IDNAC SLC shown as a Class A Riser with each IDNAC Repeater wired in/out (not T-tapped); IN only two (2) are shown, maximum is five (5) Exposed cabinet dimension for semi-flush mount 1" (25.4 mm), 1-3/8" (35 mm) with semi-flush trim 0 13-1/2" (343 mm) Knockouts for screw or nail mounting holes [0 iIiøIIII '1;'(305mm) LIE Battery location (dotted line) no conduit entry or wiring in this area, 12.7 Ah maximum EN Wiring Reference, Class A Riser Input with Class A Loop and Class B Branch Outputs 4100ES with EPS Power Supply, requires optional 4100-6103 Dual Class A IDNAC Isolator (DCAI) Requires optional 4009-9814 Class A Adapter / Module set for Branch Mode to create a local / Class A loop circuit output ( Class A Loop Extension __~4 R Z PIR 4009 IDNAC Repeaters Class B Branch Extension FIRM FIRE Wiring detail reference (repeaters - are wired same as appliances) 4009 IDNAC Repeater Mounting and Module Placement Reference 1/4"(413mm) "I Cabinet depth ['4-1/8" (105 mm) 0-29/32" (277 Door, 5/8" (16 mm) thick Optional Semi-Flush Trim Kit - Shaded Area is Non-power limited - 1-3/16" wide (30 mm), 3/8" (9.5 mm) thick Wail surface reference for semi-flush mount 5 S4009-0004-2 7/2013 4009 IDNAC Repeater Specifications Input Ratings Voltage Range 120 VAC, 50/60 Hz, or 220/230/240 VAC, 50/60 Hz, +10%, -15%, auto-select AC Input 120 VAC Current 2.5 A Ratings 220/230/240 VAC Current 1.25 A Panel IDNAC Appliances Auxiliary Load 70 mA 0.8 mA each Output current (voltage is from battery) Standby Currents 24 VDC Requirements for Battery Calculations 4.5 A maximum with 3 A IDNAC SLC load + 1.37 x output current Alarm Currents 96 mA and 200 mAAuxiliary output load (actual (voltage converter is on alarm current depends on connected and when in Alarm) activated appliances and devices) I7VRMS minimum IDNAC Input Ratings 1 address 4 unit loads Output Ratings IDNAC SLC Output 3 A maximum @ 29 VRMS for Special Application appliances Compatible Special Application Appliances Simplex TrueAlert ES and TrueAlert addressable notification appliances; contact your Simplex product representative for compatible appliances IDNAC SLC Ratings and Loading Up to 62 total addressable appliances; one address is required for the Repeater Up to 75 total unit loads (appliances are I unit load, Repeater and Isolators are 4 unit loads) Up to 62 compatible strobes can be synchronized per IDNAC SLC Current Auxiliary Output Voltage 200 mA maximum 29 VDC nominal with AC present or when Repeater is on battery standby and in Alarm 24 VDC nominal when on battery standby and not in Alarm IDNAC SLC Wiring Specifications (refer to installation instructions for more information) -- Recommended wire type UTP, unshielded twisted pair Maximum wire length allowed with 10,000 ft (3048 m) "T-Taps"_ for _class _B_wiring Maximum wire length to any appliance 4000 ft (1219 m) Maximum wiring resistance between 260 appliances Wiring Connections Terminal blocks for 18 to 12 AWG Repeater Status Indicators Green AC Power LED On with AC present, off during brownout or no AC condition Red Communications LED (COMM) Blinks when Repeater is communicating with the host control panel 4 LEDs provide up to 16 different trouble status indications; an on-board trouble scroll Yellow System Status LEDs button allows review should multiple troubles occur 4009-9814 Class A Adapter Module Option (required for Class A loop extension or for Class A output) 3 A maximum @ 29 VRMS for Special Application appliances IDNAC SLC Output Voltage Two connections, Port A and Port B, function varies by application (loop extension or local loop), Port A and Port B are isolated from each other Status LEDs Two yellow trouble LED indicators, one per Port Environmental and Technical Publications Reference Operating Temperature 32° tc 120° F (0° to 49° C) Operating Humidity Range Up to 93% RH at 90° F (32° C) Installation 4009 IDNAC Repeater 579-1019 Instructions Class A Adapter Module 579-1080 TYCO, SIMPLEX and the product names listed in this material are ma.-band/or registered marks. Unauthorized use is strictly prohibited. f3'SjMpjjEX Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4009-0004-2 7/2013 www.simplexgrinnell.com 0 2013 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. a CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION CAL OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY LISTEE: DESIGN: RATING: 7300-0026:0375 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Models 4009-9601, 4009-9601 BA, 4009-9602 and 4009-9602 BA IDNAC repeaters. Model 4009-9814 Class A Adapter card. Refer to listee's data sheet for detailed product description and operational consideration. 120V/240V INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an accessory for use with listee's separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. 04-23-13 gt Ti This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ?VG operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ®Simplex Fire Alarm Control Panel Accessories Listings* System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger liii I Rechargeable, sealed lead-acid batteries: Lead-calcium grid structure with immobilized electrolyte in absorbent separator Low maintenance with no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover with high reliability dual seal construction UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size Larger batteries, up to 110 Ah, mount in external battery cabinets with models available with internal chargers Battery cabinets with chargers: Battery cabinets with charger communicate with their connected fire alarm control panel and are available for 4100ES/401OES/4100U Series and 4010 Series panels I I41i F1TT1 Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. Where required, external battery cabinets can be close-nippled to the control panel to house larger batteries with battery chargers available in some battery cabinet sizes. I:UT1aTfl1 Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Remote Battery Cabinets are Available for Larger Battery Requirements I:1.T11(IThTh1IIJ7lT!j Shipping. Sealed lead-acid batteries are shipped via ground or sea transportation only. They are not shipped via air. Disposal. Battery chemicals and materials can be recycled. Refer to nformation shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Seismic Activity Applications. Battery brackets are available for systems tested for compliance with specific batteries. Please refer to data sheet S2081-0019 for details. * Refer to details on page 4 and to the referenced individual product data sheets for agency listing status at battery cabinets and chargers. The batfedes detailed in this document meet the requirements of UL, ULC, and Factory Mutua for use with respective equipment battery chargers as listed an page 3. Contact your local Simplex product supplier for proper battery selection pr system requirements. LisUgs and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S2081-0006-21 12/2014 Battery Size Specifications Battery Model Capacity c 20 Hour Width Depth Height with Approxima e Discharge Rate Terminals Weight 2081-9272 6.2 Ah €-i'8" (156 mm) 25I8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah 6' (153 mm) 4-1116" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg 2081-9288 12.7 Ah 6'(153 mm) (10:2 mm) 4(102mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-14" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) t4.3 lbs (6.5 kg) 2081-9287 25 Ah 6-58" (168 mm) (127 mm) 7" (178 mm) 1.9.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-112" (318 mm) 3-3/3" (36 mm) 7-1/16" (179 mm) 23.6 lbs (12.1 kg) typically for service) 2081-9276 ('square" case, 33 Ah 7-34' (197 mm) 5-1/4" (133 mm) E3/4" (171 mm) 26.5 lbs (12 kg use for new) 2081-9296 50 Ah 9" (229 mm) 5-12" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg 2081-9279 110 Ah 11-3,16(284 mm) 10-1/2" (267 mm) 9" (230 mm) 32 Lbs (37 kg) Actual appearance will vary with battery size. Quick connect or post type terminal (type varies with battery size) Inner Sealed outer cover Vent hole Potting material, back for negative, red for positive (i (polarity is also clearly marked with + and -) ( Pressure relief valve Absorbent separator used to immobilize electrolyte Lead-calcium grids Cell arou Semi-permeable / membrane separator Cell case (high impact polystyrene) * Dimensions and weight are per battery and are 'or reference only. Exact size may vary. Refer to the tables on page 3 for mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Nominal Voltage Rating 12 Volts pe- battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) 2 S2031-0006-21 1212014 Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Simplex Control Panel Model Series (see legend and notes below) Battery Capacity 4003EC 4004R 4007ES & 4006 & 4009 4010 4010ES 4I00ESI 4100 & 4120 Model 4005 4008 (all models) 410OU (2, 4 cr6-Unit) 2081-9272 6.2 Ah f / if I if if I if I 2081-9274 10 Ah It if if f if I 1 1 / 2081-9288 12.7 Ah 2081-9275 18 Ah Ext Note 3 1 Ext Ext Note 2 2081-9287 25 Ah Ext Note 3 Ext Ext NA I if I I 2081-9271 33 Ah Ext Note 3 Ext NA NA Note 3 if I Ext rectangular 2081-9276 33 Ah Ext Note 3 Ext NA NA Note 3 1 if if "square" 2081-9296 50 Ah NA Note 3 NA NA NA Note 3 Note 6 2 or 3 bay Ext 2081-9279 110 Ah Requires external battery cabinet, compatible with 4100ES, 4010ES, 4100, and 4120 Series only if = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable/not compatible NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. Some control panel models are listed for battery replacement reference only. For 2 bay international applications only, 50 Ah batteries will fit in the cabinet. External Battery Cabinet Compatibility Reference Battery Cabinets without Chargers (connects to charger in panel) Battery Cabinet Panel Compatibility 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 25 Ah Rectangular 33 Ah Square 33Ah 50 Ah 110Ah 2081 -9280 4100ES, 4OIOES, NA NA NA NA NA if 4100U, and 4100+ 2081-9281 multiple if if if if ,f NA 2081-9282 4009-9801 multiple if I" NA NA NA NA 4009-9802 multiple if NA if NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 Cabinet Panel Compatibility 18 Ah 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 4081-9301 4004R and 4010 if if I if if NA 4081-9302 4081-9306 4100ES, 4010ES, NA NA NA NA if if 4081-9308 and 41001-1 1 1 * Batteries smaller than those listed are normally mounted in the product cabinet ** 25 Ah capacity was effective as of 7/2005. if = Can be placed in the respective equipment cabinet NA = Not applicable/not compatible S2081-0006-21 12/2014 External Battery Cabinet Specification Reference Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and FM 2-Unit, 4100 style cabinet without charger; with locking solid door and battery shelf, primarily for use with 50 Ah 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red batteries 4003-9860 Beige Multiple Intended for use with 4003EC systems, for up to 33 Ah 9-1/2" H x 24" W 9" D batteries (refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm) 40099801* Beige UL and For up to 25 Ah External battery cabinet without charger, 16-1/4" W X 13-1/2" H X 53/4" D FM batteries* I with locking solid door and battery I harness; for close-nippled mounting to (413 mm x 343 mm x 146 mm)* For up to 33 Ah 25-3/4" W x 20-3/4" H x 4-1/8" 0 4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) * Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model Color Input Voltage Description Dimensions Battery cabinet with charger for the 4010 and 4081-9301 Beige 4004R fire alarm control panel; for up to 50 Ah 120 VAC batteries; with front door 22-1/2" W x16-3/4" H x 8-3/8" D (572 mm x 425 mm x 213 mm) 4081-9302 Red Listings include: UL, ULC, FM, CSFM, and MEA (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model& I Color Cabinet Description Compatible Charger Description I Dimensions Listings Chargers 4010-9xxx 401OES Main System Supply Series I (MSS) I 4100-9xxx 4100ES/4100U System Power Series Supplies (SPS) Battery cabinet for 4100-5111 2081-9279, 110 Ah 4100-5112 4100ES/41001-1 Additional SPS 2081-9280 batteries; includes 4100-5113 4100-5125 4100-5126 4100-5127 4100ES/4100U Remote Power Supply (RPS) Listings include: UL and CSFM Red 80A battery fuse, terminals and battery connection 26-1/2"Wx 12" H 12" D (673 mm x 305 mm x 305 mm) cables; see data sheet for details 4100-5121 4100-5122 4100-51204100ES/41001.1 TrueAlert Addressable Power Supply (TPS) 4100-0104 4100-0114 4100 Legacy power supplies 4100-0124 4IOOES/40I0ES/4100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081-0002) Model color Input Voltage Description Dimensions Battery cabinet with charger for up to 110 Ah 4081-9306 Red 120 VAC batteries; NOTE: Required for ULC listed charging of 27-7/8" W 13-1/2" H x 14-5/8" D 110 Ah batteries; Listings include: UL, ULC, FM, (708 mm x 343 mm x 371 mm) 4081-9308 Red 220/230/240 VAC, CSFM, and MEA (NYC), see data sheet for multi-tapped details 4100-9837 Green LED Power-on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. ®s i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 • USA S2081-0006-21 12/2014 0 2014 Tyco Fire Protection Products. All rights reserved. All specificatiens and other information shown were current as ofdocument revision date and are subject to change without notice. .simplex TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors - Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories I1Oi4.1 TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products: 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET H operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and TJLC-5530 General features: Operation is for ceiling or wall mounting Listed to UL 268 and ULC-5529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMT compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. S4098-0019-20 112015 TrueAlarm Sensor Bases and Accessories Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test 1i-i 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) AM SlmpIex flsrintion TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. reiereiice Electrical Box Requirements: (boxes are by others) Without rglay 1fl the Qx: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay in the box : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference— 1-1/2" (38 mm) minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 2098-9737 Supervised Relay 4098-9822 Relay (mounts (mounts in base electrical box or in base electrical box) remotely) Relay Size: 2-1/2" X 1-1/2' X 1" 3.75 in 3)(64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32" (1 in 3)(60.4 mm X 31.8 mm X 8.6 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. 6-3/8" (162 mm) 01 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and 4" square flush box 4-7/8" (124 mm) 15/16" (24 mm a TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 2; S4098-0019-20 1/2015 TrueAlarm Sensors Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed.temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F 60 ft x 60 ft 20 ft x 20 ft (6.1 m) for fixed (57.2° C) (18.3 m) temperature only; RTI = Quick 50ftx50ft(15.2 m) for fixed 155° F 40 ft X 40 ft temperature with either rate-of-rise (68° C) (12.2 m) selection; RTI = Ultra Fast Smoke Sensors: Photoelectric technology sensing 3600 smoke entry for optimum response Built-in insect screens [111:)i I J iTi1iIi1 MOMM i!.i TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. f -4 4-7/8' (124 mm) LED status indicator (54 mm) 4098-9714 Photoelectric Sensor with Base TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° Q. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 4-7/8" (124 mm) 0"—LED status indicator 2-3/8" (60 mm) 4098-9733 Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. IAnnIirtiôn Rfrnce Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. S4098-0019-20 1/2015 I I7TT'.1 i iw T'I-1 flT1 J7T I-flIt1I'liFTI TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model I Description I Compatibility Mounting Requirements 4098-9792 Standard Sensor Base No options 4 octagonal or 4 square box, 1-1/2 mm. depth; or single gang box, 2" mm. depth Sensor Base with connections for 2098-9808 Remote Alarm Indicator or 4098-9789 Remote LED Alarm Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay 4" octagonal or 4" square box 40989791** 4-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 2098-9737 Supervised Remote Relay Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 40989780** Sensor Supervised Relay Base with connections for LED 4098-9860 Supervised Remote Relay ** NOTE: 4098-9791 and 4098-9780 are NOT compatible with the 2120 CDT 2098-9808 Remote Alarm Indicator or Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay \\ TrueAlarm Sensors Model I Description I Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Bases 4000702 4008.070 4098-9733 4098-9791, and 4098-9780 ' Refer to base requirements TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base For use with 4098-9791 base Remote Mounting requires 4" octagonal electrical box - or 4" square box, 1-1/2" minimum depth Base Mounting requires 4" octagonal 4098-9860 Supervised Relay, mounts remote or in base For use with 4098-9780 base electrical box box, 2-1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator on single Bases 4098-9789, 4098-9791, Single gang box, 1-1/2" minimum depth gang stainless steel plate and 4098-9780 4098-9822 Unsupervised Relay, tracks base LED status; Bases 4098-9789, 4098-9791, 4" octagonal box, 2-1/8" deep with 1-1/2" Note: Mounts only in base electrical box and 4098-9780 extension ring Bases 4098-9792, 4098-9789, Required for surface or semi-flush 4098-9832 Adapter Plate 4098-9791, and 4098-9780 mounted 4" square box and for surface mounted 4" octagonal box General Operatinq Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32° to 100" F (0° to 38" C) Operating Temperature with 4098-9733 Heat Sensor Range with 4098-9714 Smoke Sensor 32" to 122° F (0° to 50° C) 15° to 122° F (-9° to 50° C) Storage Temperature Range 0° F to 140" F (-18° C to 60" C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/mm (0-1220 rn/mm) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 iA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power I Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current . Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). J3,SiMpJIEX Tyco Fire Protection Products" Westminster, MA • 01441-0001 • USA S4098-0019-20 1/2015 www.simplex-fire.com 0 2015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision dote and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098*9775, *..9776 *..9777 -9780,-9780E, -9789, -9789E, 9789T5P, -9789TTP, -9791, -9791E, -9791T5P, 9791TTP,-9792, -9792E, -9792TSP, 97921TP, -9793, -9793E, -9793T5P, -979311P,-9796, -9796TSP, -979611P; G5A4098-9780, -9792, -9793, and -9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Models 4098-9775, -9776, -9777, -9780,-9780E, -9789, -9789E, 978915P, -9789TTP, -9791, -9791E, -9791TSP, 9791T1P,-9792, -9792E, -979215P, 9792TTP, -9793, -9793E, -9793T5P, -9793TTP; GSA4098-9780, -9792 and -9793 are intended for use with: Models 4098-9714 and G5A4098-9714 photoelectric smoke detectors (CSFM Listing No. 7272-0026:0218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:0231); and Models 4098-9733, G5A4098-9733, 4098-9734 and G5A4098-9734 heat detectors (CSFM Listing No. 7270-0026:0216). Models 4098-9796, -9796T5P, -9796TTP, GSA4098-9796 are only intended for use with Models 4098-9754 or G5A4098-9754 photoelectric smoke detector (CSFM Listing No.7272-0026:0218). - These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. Refer to listee's Installation Instruction Manual for details. *Rev. 02-08-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE M®r LISTING No. 7272-0026:0218 Page 1 cf I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SimpIex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098-9714, -9774, -9714T5P, -9714TTP, -9754 -9754TSP, -9754TTP; G5A4098-9714, and -9754 analog photoelectric type smoke detectors. Models 408-9754, -9779, -9754T5P, -97541TP; G5A4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (135°F fixed temperature and 120F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and cperationa. considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed ccmpetible fire alarm control units. Units are intended for use with smoke detector bases Models 4098-9789, -9789T5P, -978911P, -9791, -9791T5P, -9775, -9776, -9777, -97211TP, -9792 -9792T5P, 979211P, -9793, 979315P, -979311P ; G5A4098-9792, and -9793 (CSFM Listing No. 7300-0026:0217); *4098..9794 -9794T5P,-97941TP (CSFM Listing No. 7300-3326:0500L Models 4098-9714, -9714T5P and -971411P are listed for use with Models 4098-9750-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:0220) and Models 4098-9755, -9755T5P and -97551TP duct detector units (CSFM Listing No. 320-CC26:0241). Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts witn air velocities between 0-2000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are gene-aly more effective at detecting fast, flaming fires that consume combustible materials rapidly anc spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineerirg staff has reviewed the test results and/or other data but does not make an independent verification of any claims This l:sting is not an endorsement or recommendation of the item listed. This listing should not be us€d to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2I'9 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division £®Simplex TrueA!arm® Analog Sensing UL, ULC, CSFM Listed; FM Approved,- Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control I1t!I14. Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNetTM or MAPNET il®, 2-wire communicationst Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNetjMAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 at the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Ushngs and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Duct Sensor Housing, Front and Bottom View 0 0 & 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station dtmtic Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. Ilrr1MdhiEN 0] gSJoltHTjTj1 Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarm sensors and lDNet and MAPNET II communications are protected by one or more of the following U.S. Patents 5155468; 5,173,683; 5,543,777; 5,400,014; 5,543,777; 5,710,541; 0383,407; D388,352; 0392,573; 4,796,025. S4098-0030-5 3/2007 TrueAlarrn Sensor Operation (Continued)_, Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) 11:21T.10, MM2= TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot receiver to provide consistent and accurate low power • Ability to display and print detailed sensor smoke sensing. information in plain English language Relays of model 4098-9756 are under panel control 3V M-for ON, OFF, or override \ Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility \i Basic i Simplex fire alarm control panel models 4010 - Duct Sensor Housing; operating power s supplied by 4098-9755 4020 4100 4100U and 4120. Also 2120 CDT if either IDNet or MAPNET II communications (no relay output) configured for MAPNET II, TrueAlarm operation - Duct Sensor Housing with supervised multiple re ay output, Same as above except relay operation is not compatible with 2120 CDT 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 Relay output is for up to 15 total 4098-9843 end-of-line resistor harness; includes one 4098-9843 relay 1 Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator Use single gang box, 4098-9755 2098-9806 Test Station with keyswitch and red LED status irdicator 4098-9756 3" H x 2" W x 2" D (turning switch to "TEST" initiates alarm for system testing) (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9756 fl Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; (1 m) of device being connect up to 15 wiring is 18 AWG (0.82 mm2 ) color coded wire leads controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kZ 1/2W; (ref. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Overall Duct Width (305 mm) Tube Required 2098-9796 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2" (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2" (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2" (51 mm) longer than duct width S4098-0030-5 312007 Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. Iiiii.Mur1I T;TTo- iui*i Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Metal plate with dual holes 9 mm) conduit, plug for unu;vie __________ — u u Yellow LED, relay control trouble indicator (4098-9756 only) D so 01 Red sensor status LED 'Niring terminals netic test area Mount as shown (preferred) with d sensor are electronics area located the LEFT or UP ONLY Totor I .iTrI : F flTI.11Iz (] NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. \ 11-3/8" (289 mm) \ [Exhaust tube access hole I Conduit b others (4098-9714 Smoke sensor, mounted in special interface base (supplied) (171 mm Fl ( Sampling tube access hole (Stationary baffle (built-ins]' [Captive fastening screws (4)J (yjj 3-3/8" (86 mm) 13/16" (21 mm) End View with Duct and Tubes [Duct hOu5,,/ 118" Round duct outline' (minimum diameter) —I 8" Square duct outline1 tube :.*.-_tI (minimum width) J S •j S S arnpHng tube, keyed for proper hole alignment with holes facing into airflow (template is I provided for proper tube installation) I 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 137/16" (38 mm) 1-3/16" (30 mm) 41 S4098-0030-5 3/2007 I IJjj.] I lit iit*i Exhaust Sensor 7 Damper OK Exhaust -Return Air Do not locate Sensor here Return air damper Fresh Supply air Air Filter - Sensor Do not locate bank OK sensor here Bend or obstruction Return ai"' 9 widths minimum 6 Duct inlet 6 Duct widths minimum Preferred Duct Sensor Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. Specifications General Mechanical and Environmental - Air Velocity Range (linear ft/mm) 300 to 4000 ft/min 191 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per :Qot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F :o 140° F (-16° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 13 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Remote Status/Alarm LED and Test Station with Remote Alarm LED Current Black base with clear cover Remote Status/Alarm LED 11.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current j 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 1250 ft (76 rn) maximum -- - - Addressable Operation Data Communications lDNeI or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24VD nominal) Standby Current 13 mA @ 24 VDC Alarm Current (one relay activated) 15 mA @24 VDC; add 15 mA for each additional remote 4098-9843 relay For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft Supervised Remote Relay Control Output (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kQ, 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use Mth Model 47j98-9756 Only Coil Current . 15 mA @ 24 VDC, ..p to 15 maximum per relay control output Relay Contacts 7Aat0.35PF@2-E. VDC &12OVAC 250 pA@SVDC Location Distance I 500 ft (152 m) maxi:1um to relay coils; relays must be within 3 ft (1 m) of device being controlled per NFPA 72 Tyco, Simplex, the Simplex logo, TrueAlarm, IDNet, and MAPNETII are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). .Simplex Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4098-0030-5 3/2007 wwv.tycosafetyproducts-usa-wrn. corn 0 2007 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098-9755, *4098..9755Tsp *4098.9755up 4098-9756, *4098..9756TSp *40989756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 -4000 feet/min INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operatioral considerations RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: listees name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with proected beam detector systems. NOTE: -p *Rev 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has .aview€d The test results and/or other data but does not make an independent verification CF any claims. This listing is not, an eidorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installatior instructions and/cr other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5impIEx UL, ULC, CSFM Listed; FM Approved* I'k! i Ii Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 "/16" 1/ square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 Description 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Model Description 4090-9010 8 A Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 I I For semi-flush I Trim plate, galvanized mounted box steel, with LED viewing I For surface I window; includes 4090-9802 I mounted box I mounting screws 4090-9813 Adapter plate to fit 4 /" (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9010, 8 A Relay lAM 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) Communications IDNet communications, I address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4 1/' H x 4" W x I %" D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32* to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) S4090-0015-1 11/2014 8 A Relay lAM Mounting Information 4" (102 rim.) square box, 2-1/3 (54 mm) minimum depth, RCJ 232 or equal `,supplied by others) Double gang blank cover plate and mounting screws. for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Pate I © © [ © © 4 9/16 WAR M It1 I I IItlItTII Add supplied label to -WARMa over on-site if controlling IAvnssa1r:I - I U U gITil 120 or 240 VAC L!J 4-5/16" (116 mm) (109mm) Light pipe for LED viewing © ©L© © --.J- 4-9/16" (116 mm). 4 4-5/16" (11 C-9 -n m) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted Dox surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are mar-_c and/or registered marks. Unauthorized use is strict'y pvohbited. B Si i-ri I EX Tyco Fire Protection Products• Westminster, MA • 01441-0001 USA S4090-0015-1 11/2014 www.simplex-flre.com 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocumcn revcs'on date and are sukeato change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexloO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4090-9118 relay IAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *40909010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verifiction of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 55im plEx TrueAlert Addressable Notification Appliances UL, ULC, CSFM Listed; FM Approved; [71 Multi-Candela Visible Only (V/O) MEA (NYC) Acceptance* L..fti Appliances (Strobes), Ceiling Mount rOTM Individually addressed and controlled multi-candela VIO (visible only) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, or 110 cd Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup Wiring supervision to each strobe allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 2) Magnet test diagnostics to assist checkout and testing of appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see page 3) UL listed to Standard 1971 and ULCS526* LED indicator and magnet test feature: Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address AND pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features: Rugged, high impact, flame retardant ceiling mount thermoplastic housings are available in red or white Rear of housing does not extend into box and easily mounts to standard electrical boxes Mounting options include red wire guards and adapters for surface mounted electrical boxes * See page 2 for wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7126-0026:235 for allowable values and/or conditions concerning material presented in this document Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Ceiling Mount Addressable V/Os I'i*iF1IMet Multi-Candela TrueAlert addressable strobes provide convenient installation to standard electrical boxes. The strobe is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 3.) t*i Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.l; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). II i] LtuIi s(Ii .ii tiITVY 1T TrueAlert addressable appliances on IDNAC SLCs provide separate visible (and audible) notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. S4906-0004-4 2/2015 Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (Refer to data sheet S4905-0001 for additional information.) Test Features. Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test. In this test mode, in response to the magnet test, the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Testing. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Product Selection Multi-Candela Ceiling Mount Addressable Strobe Model Housing FIRE Lettering Dimensions Color Description 4906-9202 Red White 4 / X 2 X 2 4 D Multi-Candela Addressable Strobe; 16 8 4906-9204 White Red (121 mm x 75 mm x 67 mm) intensity selectable as: 15, 30, 75, or 110 candela VIO Adapters (see diagram on page 3) Model Description Dimensions 4905-9910 Ceiling Mount Surface Mount Adapter Plate, zinc plated; required for 4 %" x 3 Va" (124 mm x 79 mm) ceiling surface mount Wire Guards (see diagram on page 3) Model Description Dimensions 49059926* Ceiling Mount Red wire guard with mounting plate, compatible with 6 %" x 4 %" x 2 /" semi-flush or surface mounted boxes (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc TrueAlert Device Reports Reference Service REPORT 5 Port : TrueAlert Device Report Page 1 12:34:56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label . . . up to 40 characters V/O 15 T14-1-2 Break Room 5 AN 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 30 S4906-0004-4 2/2015 Ceiling Mount VIO and Guard Installation Reference Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or Optional 4905-9926 wire iiJjJ' j/ ------guard with mounting plate r Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens - housing; factory setting is FACP, controlled by panel Single gang box (Wiremold V57445) 2-1/4" (57 mm) deep, supplied by others Address setting DlPswitch is behind strobe assembly, select address and strobe candela setting before inserting into housing Bottom view I.Magnetic test ioc ation ii r LED indicator/ equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) mount with handy box unless using the 4905-9926 ° /wire9uard Ceiling mount strobe , 4905-9910 Adapter Plate, required for surface IDNAC SLC Controller Compatibility Reference Reference Compatible Controllers Controller Output Voltage Design Reference Data Sheet IDNAC SLC Output Appliance Voltage 4009 IDNAC Repeater S4009-0004 29 VDC 23 VDC 4007ES with IDNAC Notification S4007-0002 (regulated) (with 6 VDC drop) 4010ES with ESS Enhanced System Supply S4010-0011 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC Specifications General Specifications (see page 2 for dimensions) Environmental 32" to 122° F (0" to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm"); two wires per terminal for in/out wiring Installation Instructions 579-808 Strobe St,ecifications Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application (see below for 17 VDC rating) Supervisory Requirements 1 unit load ( 0.8 mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 46 synchronized strobes maximum per NAC Candela Setting 15 c 30 c I 75 c 110 Cd 23 RMS Current Ratings, for connection to 60 mA 92 mA 180 mA 240 mA IDNAC Addressable SLCs TrueAlert Strobe LEGACY Compatibility Reference Compatible Controller Data Sheet Controller Output Available Strobe Appliance Voltage Reference Intensity Minimum 4100ES or 4100U with TrueAlert Power Supply S4100-0031 Addressable SLC 110 cd 17 VDC 4009 TPS, Remote TrueAlert Power Supply S4100-0037 TrueAlert 15, 30, 75, and TrueAlert Addressable Controller (4009T) S4009-0003 Electrical Ratings Difference for Retrofit Applications Voltage Range 17 VDC to 31 VDC, Special Application Candela Setting 15 c 30 c 75 c 110 Cd 17 VDC RMS Current Ratings, use when nn coected to TrueAlert Addressable SLCs per 76 mA 128 mA 242 mA 328 mA above 3 S4906-0004-4 2/2015 TYCO, SJIVIPLEX and the product naes listed in this material are marks and/or regis'rsd marks. !nauthorized use is srictly prohibited. NFPA 7' sndNaional Firs Alarm and Signalirg Code are registered irsdesysrks of the Naticnal Fire Protection Assocatios 7'-'F4). ®S i ITi p1 EX Tyco Fire Protection Products e in:te,:,MA 01441-0001 • USA S4906-0004-4 2/2015 0 2015 7'y-co Fire Protection Prc'ducs. .l rights reserved. All specifications and other info rmaon shown were current as ofdocument revision dote and cre szJsect to change 14ithout notice. p CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0235 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models "TrueAlert non-addressable "4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable "4904-9168, 4904-9171, 4904-9169, 4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904-9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904-9360, 4909-9361 synchronized strobe lights. Models "TrueAlert addressable" 4906-9201, -9202, -9203, -9204, and -9208 synchronized multi-candela strobe lights are intended for indoor use. *Models 4906-9201, -9203 and -9208 are intended for wall mount only. *Models 4906-9202 and -9204 are intended for ceiling mount only. Intended for use with either Model 4209-9401 NAC Extender or with the TrueAlert power supply of Model 4100U fire alarm control panel. Model 4906-9208 employs two lenses, clear lens for "Fire" and amber for "Non-Fire". Model 4905-9938 sync control module. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, -9353, -9356, -9359, -9168, -9171: 15cd, 1 Hz. 4904-9332, -9343, -9351, -9354, -9357, -9360, -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, -9352, -9355, -9358, -9361: 110cd, 1 Hz. Models 4906-9201, -9202, -9203, -9204, -9208: 15, 30, 75, 110cd, 1 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. *Rev 04-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5®Sim plEx TrueAlert Addressable Notification Appliances UL, ULC Listed* 71 Wall and Ceiling Mount Addressable Speaker H-f-1 and Speaker Visible Notification Appliances I(iI&4.1 Individually addressed and controlled Speaker (SIO) and Speaker Visible (SN) notification appliances Advanced addressable notification controlled by IDNAC SLCs provides regulated 29 VDC for low current operation even under battery backup. Wiring supervision is electronically monitored and allows audio wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Speaker selectivity is controlled by the panel. Only those speakers that are needed are connected to the audio NAC. Separate appliance and cover selection greatly simplifies the ordering and installation process. Strobe intensity can be programmed from the control panel or the device for S/V models. Self-Test Mode allows on-board sensors to detect the strobe and speaker output and then report their status to the control panel. Wiring terminals separate from the Audio terminals. TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting. Magnet test diagnostics to assist checkout and testing of appliances and wiring. Compatibility with ADA requirements. LED indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address and pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount models Covers are available in red or white with various lettering options Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts to 4" square 2 Ye" gang US electrical boxes * Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Ceiling and Wall Mount Addressable Speaker Only and Speaker Visible Strobes I lit- wt7ifl1il10 iI Speaker design features High quality voice and tone reproduction with taps for ¼, ¼, 1, or 2W, at 25 or 70.7 VRMS Speakers have capacitor input for connection to DC supervised NACs and are wired separately from strobes Listed to UL 1480 and TILC S541* Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas High and low frequency response models available, 200-10000 Hz and 400-4000 Hz respectively. I 'i riiri Wall and ceiling mount addressable speaker and speaker visible appliances provide convenient installation to standard electrical boxes. The speaker is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). Audio is provided by a panel that supports audio output or from a separate audio source. Appliances use a multi-tapped speaker for audio/tone notification. Fi71 1ITUT1zi Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S49SWC-0001-1 11/2015 TrueAlert Addressable speaker and speaker visible appliances on IDNAC SLCs provide visible and audio notification using two separate two-wire circuits that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. irirwx r I 11r'A' ii 1I. 1= Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. iTfTiflI *I']* iii.iit Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance's address when a magnet is applied. Operational Appliance Testing In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Lfl I ii r. rn.N1 I i mr*iMr. rr.'T r1M Wall Mount S/O Appliances* (Refer to data sheet S49SOW-0001 for full product selection including covers and mounting plates) Model Dimensions I De script on Data Sheet Reference 49S0-APPLW(-BA) 1 5 1/2 H x 5" Wx I Y2" D SIO appliance only s49s0w-0001 49HF-APPLW(-BA) (139 mm x 128 mm x 38 mm) High fideliy SIO appliance only Wall Mount SN Appliances* (Refer to data sheet S49SVW-0001 for full product selection including covers, mounting plates, and multi-color strobe lens) Model Series Dimensions Description Data Sheet Reference 49SV-APPLW(-BA) 7 %" H x 5" W x 1 3/4" D SN appliance only 849Svw-0001 49HFV-APPLW(-BA) (187 mm x 128 mm x 43 mm) High fidelity SN appliance only *Note: Wall mount models require separately ordered back plate. See related datasheet for details LCeiling IMount 1Appliance iProduct Selection 1, Ceiling Mount S/O Appliances (Refer to data sheet S49SCC-000 for full product selection and installation requirements) Model Dimensions Descripticn Data Sheet Reference 49 S O-APPLC(-BA 17 i/a" H x 7 1/8 W x 1 1/4 D E/O appliance only S49Soc-0001 49HF-APPLC(-BA) 1( 180 mm x 180 mm x 32 mm) High fidelit" SIO appliance only Ceiling Mount SN Appliances (Refer to data sheet S49SVC-0001 for full product selection and installation requirements) Model Series Dimensions Description Data Sheet Reference 49SV-APPLC(-BA) SN aoolia'ce only 49HFV-APPLC(-BA) 8%"Hx7Y8"Wx3"D High fidelity SN appliance only 49SVH-APPLC(-BA) High candela SN appliance only Clear lens high fidelity high candela 49HFVH-APPLC(-BA) (206 mm x 180 mm x 76 mm) SA/appliance only S49SVC-0001 Amber lens high fidelity high 49HFVH-APLCA-BA candela SI] appliance only Sue lens high fidelity high candela 49HFVH-APLCB-BA SN appliance only Note: Select appliance, cover and mounting back plate (where required) separately. (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA S49SWC-0001-1 11/2015 IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 4100ES Constant Supervision and Signal Cards Specifications General Specifications (refer to individual model data sheets for further specifications, install and operation details) Typical Operating Voltage Range,. 23 - 30 VDC, Special Application Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm' to 3.31 mm'); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible fire panel installation instructions for circuit current load limits. Speaker Specifications Input Voltage 25 or 70.7 Vrms Power Taps 1h,/2,1, and 2W 400 to 4000 Hz and 200 to 10000 Hz, Frequency Response resoctivlv General Signaling = 125 to 12 kHz Strobe Specifications Typical Operating Voltage Range 23 - 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate 1 Hz IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) UTP, unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 ft (3048 m) Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Note: Speakers are for connection to compatible fire alarm audio circuits only. S49 Series Speaker Datasheet Reference Model Data Sheet Reference Wall Mount Speaker Only Appliance S49SOW-0001 Wall Mount Speaker Visible Appliance S49SVW-0001 Ceiling Mount Speaker Only Appliance S49SOC-0001 Ceiling Mount Speaker Visible Appliance S49SVC-0001 S49SWC-0001-1 11/2015 70 TYCO, SI1vIPLEX ard the product names listed in this material are marks and/or rsgisterec marlc ilnaufrorizeduso is strictiprohibtsd. NFPA 72 and National Fire Alarm and Signaling Code are reg.stered t-ademarks of the National Fire Protection Associat:on (1"FFA). 93 S I Tyco Fire Protection Products. Westminster, MA • 01441-0001 USA, S49SWC-0001-1 11/2015 www. simplex-fire.om 02015 Tyco Fire Pro ecson Products. All rights reserved All specifications and other .eIormction showi were current as of document revisiot dote and are subjest to change witkcut nooce. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models: 49SV-APPLC,49HFV-APPLC,49SV-APPLC-BA,49HFV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA,49SVH-APPLC,49H FVH-APPLC,495V-CWF,49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 49SV-APPLW,49HFV-APPLW,49SV-APPLW-BA,49HFV-APPLW-BA,495V-WRF, 49HFV-WRF, *49SVAPPLW0 *49SVAPPLW0BA *49SVAPPLWCO True Alert ES, Addressable wall mounted Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor and outdoor use. Refer to listee's Installation Instruction Manual for details. *Revision 04-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct vi operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Contractor's License Detail for License # 986047 DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. CSLB complaint disclosure is restricted by law (B&P 7124.6) If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. Per B&P 7071.17 only construction related civil judgments reported to the CSLB are disclosed. Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. Business Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number: (562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/3112019 License Status This license is current and active. OJI information below should be reviewed. Classifications C10 - ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR Bonding Information Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond of Qualifying Individual This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for TIMOTHY PAUL ROSTEN in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC310893 tEffective Date: 10/01/2017 Expire Date: 10/01/2018 Workers' Compensation History Other Personnel listed on this license (current or disassociated) are listed on other licenses.