Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2637 GARFIELD ST; ; FPR2016-0033; Permit
PERMIT REPORT 4ity of Carlsbad Print Date: 02/10/2022 Job Address: 2637 GARFIELD ST, CARLSBAD, CA 92008-2217 Permit Type: FIRE-Construction Residential Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2016-0033 Status: Closed - Finaled Single Family Fire Sprinkli Applied: 12/15/2016 Issued: 12/15/2016 Finaled Close Out: 05/13/2021 Inspector: Final Inspection: Project Title: Description: GARFIELD RESIDENCE FIRE SPRINKLER 13D NEW SYSTEM FOR SINGLE FAMILY DWELLING Applicant: FPContractor: INNOVATIVE FIRE PROTECTION INNOVATIVE FIRE PROTECTION INC DERIK BROOKS 8779 COTTONWOOD AVE. # STE 101 8779 COTTONWOOD AVE SANTEE, CA 92071-4457 SANTEE, CA 92071-4457-SAN DIEGO (619) 593-8200 (619) 593-8200 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 Total Fees: $360.00 Total Payments To Date: $360.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE #101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR GARFIELD RESIDENCE 2637 GARFIELD STREET. CARLSBAD, CA. 92008 1 HEAD CALC FILE NUMBER: C6438 DATE: 11/10/2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 172 sq. ft. COVERAGE PER SPRINKLER: 20' X 20 400 sq. ft. NUMBER OF SPRINKLERS CALCULATED: ONE sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 21.0 gpm TOTAL WATER REQUIRED (including hose): 26.0 gpm FLOW AND PRESSURE (@ BOR) : 21.0 gpm @ 33.1 psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC DESIGN/LAYOUT BY: DAVIN BROOKS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 ' DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(1HD).SDF JOB TITLE: GARFIELD RESIDENCE WATER SUPPLY DATA . SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 63.0 . 54.0 500.0 63.0 26.0 51.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE.TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 51.9 26.0 2 0.0 - - - - 47.9 - - - 2A 0.0 - - - - 43.9 D 0.0 - - - - 43.6 C 0.0 - - - - 38.6 - - - 23 0.0 HOSE STREAM 37.8 .5.0 2C 0.0 - - - - 37.6 3A 0.0 - - - - 36.6 3B 5.0 - - - - 34.0 3 7.0 - - - - 33.1 - - - 4 9.0 - - - - 32.1 - - - 4A 9.0 - - - - 29.1 5 14.0 - - - - 25.8 6 15.0 - - - - 25.3 7 14.0 - - - - 25.6 8 14.0 - - - - 24.8 - - - 9 25.0 - - - - . 20.7 10 25.0 - - - - 20.7 11. 25.0 .---- . 20.1 12 25.0 - - - - 20.0 13 25.0 - - - - 19.0 - - - 14 . 36.0 - - - - - 15.9 - - - 15 36.0 - - - - . 15.2 - - - 16 36.0 - - - - 15.4 - - - 16A 36.0 - - - - 15.4 - - - 17 36.0 . - - - - 15.9 - - - 101 36.0 - - - - 15.4 - - - 102 36.0 -. - - - 15.4 - - - 201 36.0 - - - - 15.9 - - - 202 36.0 - - - - . 15.9 - - - 195 25.0 K= 4.90 18.4 21.0 • .,- ,•-• - .-- - -' ,• :---- -- 01* -. -'-•- --- -•.-; SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD BESIDENCE(1HD).SDF JOB TITLE: GARFIELD RESIDENCE PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) - FT) SUM. NODES (FT) (K) (PSI (GPM) FL/FT (PSI) Pipe: 1 26.0 0.995 FL 1E.00 PF 4.0 - 1 0.0 SRCE 5.. (N/A) 10.7 - -150 FTG TG PE 0.0 2 0.0 0.0 4".3 0.0 0.182 TL 22.00 PV - Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 6.0 4. 0.0 4.0 psi, 26.0 gpn - 2A 0.0 0.0 43.3 0.0 Pipe: 3 26.0 1.025 FL 2.00 PF 0.3 2A 0.0 0.0 43.3 0.0 10.1 150 FTG ---- PE 0.0 D 0.0 0.0 43.6 0.0 0.157 TL 2.00 PV - Pipe: 4 FIXED PRESSURE LOSS DEVICE D 0.0 0.0 43.6 0.0 5.0 psi, 26.0 gpm. C 0.0 0.0 -38.6 0.0 Pipe: 5 - 26.0 1.025 PL 2.00 PF 0.8 C - 0.0 0.0 38.6 0.0 101 150 FTG E FE 0.0 2B 0.0 H.S. 37.3 5.0 - 0.157 TL 5.00 PV Pipe: 5A 21.0 1.025 PL 2.00 SF 0.2 2B 0.0 H.S. 37.8 5.0 8.2 150 FTG ---- SE 0.0 2C 0.0 0.0 37.6 0.0 0.105 TL 2.00 ?V Pipe: 6 21.0 1.610 ?L 70.00 ?F 1.0 2C 0.0 0.0 37.6 0.0 3.3 150 FTG 23 SE 0.0 3A 0.0 - 0.0 36.6 - 0.0 - 0.012 TL 85.00 PV Pipe: 7 21.0 1.265 FL 7.0:) PF 0.5 3A 0.0 0.0 35.6 0.0 5.4 150 FTG 23 FE -2.2 3B • 5.0 0.0 3.0 0.0 0.038 TL :3.0) PV Pipe: 8 - • 21.0 1.394 FL 2.00 SF 0.0 3B 5.0 0.0 34.0 0.0 4.4 150 FTG ---- FE -0.9 3 7.0 0.0 33.1 0.0 0.024 TL 2.0) PV Pipe: 9 21.0 1.380 PL 2.03 FE' 0.1 • 3 7.0 0.0 33.1 0.0 4.5 120 FTG ---- FE -0.9 4 9.0 0.0 32.1 0.0 0.037 TL 2.00 PV - * Pipe: 10 FIXED PRESSURE LOSS DEVICE 4 9.0 0.0 32.1 0.0 3.0 psi, 21.0 gDrn 4A 9.0 0.0 29.1 0.0 Pipe: 11 21.0 1.394 FL 17.03 PF 1.1 4A 9.0 0.0 29.1 0.0 4.4 150 FTG 3ET SE -2.2 5 14.0 0.0 25.8 0.0 0.024 'L 47.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(1HD).SDF JOB TITLE: GARFIELD RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12 9.5 1.394 PL 8.00 PF 0.1 5 14.0 0.0 25.8 0.0 2.0 150 FTG 2E PE -0.4 6 15.0 0.0 25.3 0.0 0.005 TL 24.00 PV Pipe: 13 11.5 1.394 PL 11.00 PF 0.2 5 14.0 0.0 25.8 0.0 2.4 150 FTG 3T PE 0.0 7 14.0 0.0 25.6 0.0 0.008 TL 29.00 PV Pipe: 14 11.5 1.101 PL 17.00 FE' 0.8 7 14.0 0.0 25.6 0.0 3.9 150 FTG E2T PE 0.0 8 14.0 0.0 24.8 0.0 0.025 TL 34.00 PV Pipe: 15 9.5 1.394 PL 15.00 PF 0.2 6 15.0 0.0 25.3 0.0 2.0 150 FTG 2ET PE -4.3 9 25.0 0.0 20.7 0.0 0.005 TL 37.00 PV Pipe: 16 11.5 1.101 FL 19.00 PF 1.1 8 14.0 0.0 24.8 0.0 3.9 150 FTG 2E2T PE -4.8 13 25.0 0.0 19.0 0.0 0.025 TL 43.00 PV Pipe: 17 9.5 1.394 PL 2.00 PF 0.0 9 25.0 0.0 20.7 0.0 2.0 150 FTG T PE 0.0 10 25.0 0.0 20.7 0.0 0.005 TL 8.00 PV Pipe: 18 9.5 1.101 FL 14.00 PF 0.6 10 25.0 0.0 20.7 0.0 3.2 150 FTG 4T PE 0.0 11 25.0 0.0 20.1 0.0 0.017 TL 34.00 PV Pipe: 19 9.5 1.101 PL 2.00 PF 0.1 11 25.0 0.0 20.1 0.0 3.2 150 FTG T PE 0.0 12 25.0 0.0 20.0 0.0 0.017 TL 7.00 PV Pipe: 20 9.5 1.101 PL 29.00 PF 1.0 12 25.0 0.0 20.0 0.0 3.2 150 FTG E5T PE 0.0 13 25.0 0.0 19.0 0.0 0.017 TL 61.00 PV Pipe: 21 0.0 1.394 PL 15.00 PF 0.0 10 25.0 0.0 20.7 0.0 0.0 150 FTG 2ET PE -4.8 14 36.0 0.0 15.9 0.0 0.000 TL 37.00 PV Pipe: 22 0.0 1.101 PL 26.00 PF 0.0 11 25.0 0.0 20.1 0.0 0.0 150 FTG 2ET PE -4.8 16 36.0 0.0 15.4 0.0 0.000 TL 45.00 PV Pipe: 23 0.0 1.101 PL 15.00 PF 0.0 12 25.0 0.0 20.0 0.0 0.0 150 FTG 2ET PE -4.8 15 36.0 0.0 15.2 0.0 0.000 TL 34.00 PV. Pipe: 24 0.0 1.101 PL 21.00 PF 0.0 14 36.0 0.0 15.9 0.0 0.0 150 FTG 4T PE 0.0 17 36.0 0.0 15.9 0.0 0.000 TL 41.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 11/10/2016 1 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(1HCu .SDF JOB TITLE: GARFIELD RESIDENCE - PIPE TAG Q(GPM), DIA(IN) LENGTH PRESS., END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 0.0 1.101 PL 2.00 PF 0.0 16 36.0 0.0 15.4 0.0 0.0 150 FTG T PE 0.0 16A 36.0 0.0 15.4 0.0 0.000 TL 7.00 PV Pipe: 26 0.0 1.101 PL 1.00 PF 0.0 16A 36.0 0.0 15.4 0.0 0.0 150 FTG E PE 0,0 101 36.0 0.0 15.4 0.0 0.000 TL :8.00 PV Pipe: 27 0.0 1.101 PL 12.00 PF 0.0 16A 36.0 0.0 15.4 0.0 0.0 150 FTG 2E PE 0..0 102 36.0 0.0 15.4 0.0 0.000 TL 26.00 PV Pipe: 28 0.0 1.101 PL 8.00 PF 0.0 17 36.0 0.0 15.9 0.0 0.0 150 FTG 2ET PE 0.0 201 36.0 0.0 15.9 0.0 0.000 TL 27.00 PV Pipe: 29 0.0 1.101 PL 8.00 PF 0.0 201 36.0 0.0 15.9 0.0 0.0 150 FTG 5E PE 0.0 202 36.0 0.0 15.9 0.0 0.000 TL 43.00 PV Pipe.: 30 21.0 1.101 PL 1.00 PF 06 13 25.0 0.0 19.0 0.0 7.1 150 FTG E PE 0.0 195 25.0 4.9 18.4 21.0 0.074 TL 8.00 PV NOTES (BASS): Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an avera;e imbalance at each node of 0.007 gpm and a maximum imbalance at any node of 0.187 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from .the calculation report. Available pressure at source node 1 under full flcw conditions is 62.95 psi compared to the minimum required pressure of 20.00 psi. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 , DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(1HD) .SDF JOB TITLE: GARFIELD RESIDENCE (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli'Tee LngEll ChkVlv BfyVlv GatVlv NPTee 1.610 7.50 8.00 2.10 0.00 0.00 0.00 0.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E T R K C G 45 El Tee RunT Kplg ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 1.394 2.00 8.00 6.00 1.00 1.00 11.00 3.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Eli TeeRun Koupig ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Eli Tee 45-Eli TeeRun Kouplg ChkVlv GatVlv NPTee 1.025 3.00 7.00 1.00 2.00 0.00 7.00 0.00 7.00 1.265 3.00 6.00 1.00 2.00 0.50 7.00 0.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(1HD) .SDF JOB TITLE: GARFIELD RESIDENCE ml a) 0 (I) (I) a) 4J C: —L 4 0)4-) a) fli .1-) 0 C -H 1)4-) El Ci Ed ow 4-4 C ro a w H4J co ci) 0 4J C: 04 nj 04 . -i ci) ,-4J C 14 a) a) 4J -) (j C-) -H C C C C I) a) -H I- a) a) -H ,CU) U) (i 00 r (N ci) 4J 0 z I. N O 0 Cl 0 0 C 0 • • • • • • C 0 C 0 0 0 0 0 • N -D LI) U) 4 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(1HD).SDF JOB TITLE: GARFIELD RESIDENCE WATER SUPPLY CURVE 72+ 66+ O\\ \\\ 60+ \\\ \\\ \\\ 54+ * <-54.0 psi 8 500 gpm X Flow Test Point P 48+ R I E I S I S42+ U I R I El 36+ P I S I 130+ 24+ 18+ 12+ LEGEND I, X = Required Water Supply 51.93 PSj 0 26.0 qpm 6+ I 0= Available Water Supply 62.96 psi 8 26.0 gpm 0 +-----+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) INNOVATIVE FIRE PROTECTION, INC. - 8779 COTTONWOOD AVENUE #101 -ff(2.6Lc--oô SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR GARFIELD RESIDENCE 2637 GARFIELD STREET. CARLSBAD, CA. 92008 2 HEAD CALC FILE NUMBER: C6412 DATE: 11/10/2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 195 sq. ft. COVERAGE PER SPRINKLER: 16' X 16' 256 sq. ft. NUMBER OF SPRINKLERS CALCULATED: TWO sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 27.2 gpm TOTAL WATER REQUIRED (including hose): 32.2 gpm FLOW AND PRESSURE (@ BOR) : 27.2 gpm @ 37.0 psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC DESIGN/LAYOUT BY: DAVIN BROOKS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER:' C16-711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HDA) .SDF JOB TITLE: GARFIELD RESIDENCE WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 63.0 54.0 500.0 62.9 32.2 59.3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 32.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 27.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 59.3 32.2 2 0.0 -, - - - 53.4 - - - 2A 0.0 ---- 49.4 D 0.0 - - - - 49.0 - - - C 0.0 - - - - 44.0 - - - 2B 0.01 HOSE STREAM 42.8 5.0 2C 0.0 - - - - 42.5 - - - 3A 0.0 ---- 40.9 3B 5.0 - - - - 37.9 3 7.0 - - - - 37.0 4 9.0 - - - - 36.0 - - - 4A 9.0 - - - - 33.0 - - - 5 14.0 - - - - 29.0 6 15.0 - - - - 28.1 - - - 7 14.0 - - - - 29.0 - - - 8 14.0 - - - - 28.7 - - - 9 25.0 - - - - 22.9 10 25.0 - - - - 22.7 11 25.0 - - - - 23.0 12 25.0 - - - - 23.0 13 25.0 - - - - 23.5 14 36.0 - - - - 16.5 - - - 15 36.0 - - - - 18.3 - - - 16 36.0 - - - - 18.2 - - - 16A 36.0 - - - - 18.2 - - - 17 36.0 - - - - 11.6 - - - 101 36.0 - - - - 18.2 - - - 102 36.0 - - - - 18.2 - - - 201 36.0 K= 4.90 8.4 14.2 202 36.0 K= 4.90 7.0 13.0 195 25.0 - - - - 23.5 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(2HDA) .SDF JOB TITLE: GARFIELD RESIDENCE PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 - 32.2 0.995 PL 15.00 PF 5.9 1 0.0 SRCE 59.3 (N/A) 13.3 150 FTG TG PE 0.0 2 0.0 0.0 53.4 0.0 0.268 TL 22.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 53.4 0.0 4.0 psi, 32.2 gpm 2A - 0.0 0.0 49.4 0.0 Pipe: 3 32.2 1.025 PL 2.00 PF 0.5 2A 0.0 0.0 49.4 0.0 12.5 150 FTG ---- PE 0.0 D 0.0 0.0 49.0 0.0 0.232 TL 2.00 PV Pipe: 4 FIXED PRESSURE LOSS DEVICE D 0.0 0.0 49.0 0.0 5.0 psi, 32.2 gpm C 0.0 0.0 44.0 0.0 Pipe: 5 32.2 1.025 PL 2.00 PF 1.2 C 0.0 0.0 44.0 0.0 12.5 150 FTG E PE 0.0 2B 0.0 H.S. 42.8 5.0 0.232 TL 5.00 PV Pipe: 5A 27.2 1.025 PL 2.00 PF 0.3 2B 0.0 H.S. 42.8 5.0 10.6 150 FTG ---- PE 0.0 2C 0.0 0.0 42.5 0.0 0.170 TL 2.00 PV Pipe: 6 27.2 1.610 PL 70.00 PF 1.6 2C 0.0 0.0 42.5 0.0 4.3 150 FTG 2E PE 0.0 3A 0.0 0.0 40.9 0.0 0.019 TL 85.00 PV Pipe: 7 27.2 1.265 PL 7.00 PF 0.8 3A 0.0 0.0 40.9 0.0 6.9 150 FTG 2E PE -2.2 3B 5.0 0.0 37.9 0.0 0.061 TL 13.00 PV Pipe: 8 27.2 1.394 PL 2.00 PF 0.1 3B 5.0 0.0 37.9 0.0 5.7 150 FTG ---- PE -0.9 3 7.0 0.0 37.0 0.0 0.038 TL 2.00 PV Pipe: 9 27.2 1.380 PL 2.00 PF 0.1 3 7.0 0.0 37.0 0.0 5.8 120 FTG ---- PE -0.9 4 9.0 0.0 36.0 0.0 0.060 TL 2.00 PV Pipe: 10 - FIXED PRESSURE LOSS DEVICE 4 9.0 0.0 36.0 0.0 - 3.0 psi, 27.2 gpm 4A 9.0 0.0 33.0 0.0 Pipe: 11 - 27.2 1.394 PL 17.00 PF 1.8 4A 9.0 0.0 33.0 0.0 5.7 150 FTG 3ET PE -2.2 5 14.0 0.0 29.0 0.0 0.038 TL 47.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HDA) .SDF JOB TITLE: GARFIELD RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K). (PSI) (GPM) FL/FT (PSI) Pipe: 12 20.7 1.394 PL 8.00 PF 0.6 5 14.0 0.0 29.0 0.0 4.4 150 FTG 2E PE -0.4 6 15.0 0.0 28.1 0.0 0.023 TL 24.00 PV Pipe: 13 6.5 1.394 PL 11.00 PF 0.1 5 14.0 0.0 29.0 0.0 1.4 150 FTG 3T PE 0.0- 7 14.0 0.0 29.0 0.0 0.003 TL 29.00 PV Pipe: 14 - 6.5 1.101 PL - 17.00 PF 0.3 7 14.0 0.0 29.0 0.0 2.2 150 FTG E2T PE 0.0 8- 14.0 0.0 28.7 0.0 0.008 TL 34.00 PV Pipe: 15 20.7 1.394 PL 15.00 PF 0.9 6 15.0 0.0 28.1 0.0 4.4 150 FTG 2ET PE -4.3 9 25.0 0.0 22.9 0.0 0.023 TL 37.00 PV Pipe: 16 6.5 1.101 PL 19.00 PF 0.4 8 14.0 0.0 28.7 0.0 2.2 150 FTG 2E2T PE -4.8 13 25.0 0.0 23.5 0.0 0.008 TL 43.00 PV Pipe: 17 20.7 1.394 PL 2.00 PF 0.2 9 25.0 0.0 22.9 0.0 4.4 150 FTG T PE 0.0 10 25.0 0.0 22.7 0.0 0.023 TL 8.00 PV Pipe: 18 -6.5 1.101 PL 14.00 PF 0.3 10 25.0 0.0 22.7 0.0 2.2 150 FTG 4T PE 0.0 11 25.0 0.0 23.0 0.0 0.008 TL 34.00 PV Pipe: 19 -6.5 1.101 PL 2.00 PF 0.1 11 25.0 0.0 23.0 0.0 2.2 150 FTG T PE 0.0 12 25.0 0.0 23.0 0.0 0.008 TL 7.00 PV Pipe: 20 -6.5 1.101 PL 29.00 PF 0.5 12 25.0 0.0 23.0 0.0 2.2 150 FTG E5T PE 0.0 13 25.0 0.0 23.5 0.0 0.008 TL 61.00 PV Pipe: 21 27.2 1.394 PL 15.00 PF 1.4 10 25.0 0.0 22.7 0.0 5.7 150 FTG 2ET PE -4.8 14 36.0 0.0 16.5 0.0 0.038 TL 37.00 PV Pipe: 22 0.0 1.101 PL 26.00 PF 0.0 11 25.0 0.0 23.0 0.0 0.0 150 FTG 2ET PE -4.8 16 36.0 0.0 18.2 0.0 0.000 TL 45.00 PV Pipe: 23 0.0 1.101 PL 15.00 PF 0.0 12 25.0 0.0 23.0 0.0 0.0 150 FTG 2ET PE -4.8 15 36.0 0.0 18.3 0.0 0.000 TL 34.00 PV Pipe: 24 27.2 1.101 PL 21.00 PF 4.9 14 36.0 0.0 16.5 0.0 9.2 150 FTG 4T PE 0.0 17 36.0 0.0 11.6 0.0 0.120 TL 41.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(2HDA).SDF JOB TITLE: GARFIELD RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 0.0 1.101 PL 2.00 PF 3.0 16 36.0 0.0 18.2 0.0 0.0 150 FTG T PE 3.0 16A 36.0 0.0 18.2 0.0 0.000 TL 7.00 PV Pipe: 26 0.0 1.101 PL 1.00 PF 0.0 16A 36.0 0.0 18.2 0.0 0.0 150 FTG E PE 0.0 101 36.0 0.0 18.2 0.0 0.000 TL 8.00 PV Pipe: 27 0.0 1.101 PL 12.00 PF 0.0 16A 36.0 0.0 18.2 0.0 0.0 150 FTG 2E PE. 0.0 102 36.0 0.0 18.2 0.0 0.000 TL 26.00 pv Pipe: 28 27.2 1.101 PL 8.00 PF 3.2 17 36.0 0.0 11.6 0.0 9.2 150 FTG 2ET PE 0.0 201 36.0 4.9 8.4 14.2 0.120 TL 27.00 PV Pipe: 29 13.0 1.101 PL 8.00 PF 1.3 201 36.0 4.9 8.4 14.2 4.4 150 FTG 5E PE 0.0 202 36.0 4.9 7.0 13.0 0.031 TL 43.00 PV Pipe: 30 0.0 1.101 PL 1.00 PF 0.0 13 25.0 0.0 23.5 0.0 0.0 150 FTG E PE 0.0 195 25.0 0.0 23.5 0.0 0.000 TL 8.00 PV NOTES (HASS) : Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.073 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 13.3 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 62.94 psi compared to the minimum required pressure of 20.00 iJ5i. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HDA) .SDF JOB TITLE: GARFIELD RESIDENCE (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEil ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli Tee LngEll ChkVlv BfyViv GatVlv NPTee 1.610 7.50 8.00 2.10 0.00 0.00 0.00 0.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E T R K C G 45 El Tee RunT Kplg ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 1.394 2.00 8.00 6.00 1.00 1.00 11.00 3.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Eli Tee 45-Eli TeeRun Kouplg ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Eli Tee 45-Eli TeeRun Koupig ChkVlv GatVlv NPTee 1.025 3.00 7.00 1.00 2.00 0.00 7.00 0.00 7.00 1.265 3.00 6.00 1.00 2.00 0.50 7.00 0.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HDA) .SDF JOB TITLE: GARFIELD RESIDENCE a) 0 0 U) U) Ui 4J,C H4J U)4J U) (U rl 4) 0 U) -H a)) E-' 0 E'd 0 a) 4-4 U) (U a) U) H4J rU U) a) dU) U) 0 rU (U 4) U) I a) a) -ii -1 (U (U 0 -H U) ,a) U) U) U) a) a) -H P ci) j 4J U) -H U) (U 00 H 04 'I) 4J 0 z 1J4 N C C C C C C C • • • • • C o 0 C • C • C C C • N Li) (0 ('4 Cl W0I)a4 C4 Ix1U)U)Ix) -0U)H--- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HDA) .SDF JOB TITLE: GARFIELD RESIDENCE WATER SUPPLY CURVE 72+ 66+ I \\\ 60X \\\ \\\ 54+ * <-54.0 psi 8 500 gpm I Flow Test Point P 48+ R I E I S I S42+ U I R I E I 36+ P I S I 30+ 24+ 18+ 12+ LEGEND I 'I I X = Required Water Supply I 59.34 psi 8 32.2 qpm 6+ I 0 = Available Water Supply I 62.94 psi 8 32.2 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE #101 SAMTEE,CA 92071 HYDRAULIC CALCULATIONS FOR GARFIELD RESIDENCE 2637 GARFIELD STREET. CARLSBAD, CA. 92008 2 HEAD CALC FILE NUMBER: C6412 DATE: 11/10/2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 117 sq. ft. COVERAGE PER SPRINKLER: 16' X 16' 256 sq. ft. NUMBER OF SPRINKLERS CALCULATED: TWO sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 26.5 gpm TOTAL WATER REQUIRED (including hose): 31.5 gpm FLOW AND PRESSURE (@ BOR): 26.5 gpm @ 33.9 psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC DESIGN/LAYOUT BY: DAVIN BROOKS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HD) .SDF JOB TITLE: GARFIELD RESIDENCE WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 63.0 54.0 500.0 62.9 31.5 55.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.5 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.5 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 55.9 31.5 2 0.0 - - - - 50.2 - - - 2A 0.0 - - - 46.2 - - - D 0.0 - - - - 45.7 C 0.0 - - - - 40.7 2B 0.0 HOSE STREAM 39.6 5.0 2C 0.0 - - - - 39.3 - - - 3A 0.0 - - - - 37.8 33 5.0 - - - - 34.9 - - - 3 7.0 - - - - 33.9 4 9.0 - - - - 32.9 - - - 4A 9.0 - - - - 29.9 - - - 5 14.0 - - - - 26.1 - - - 6 15.0 - - - - 25.3 7 14.0 - - - - 25.9 8 14.0 - - - - 25.3 9 25.0 - --- 20.3 10 25.0 - - - - 20.2 - - - 11 25.0 - - - - 18.5 - - - 12 25.0 - - - - 18.7 - - - 13 25.0 - - - - 19.8 - - - 14 36.0 - - - - 15.5 - - - 15 36.0 - - - - 13.9 16 36.0 - - - - 8.6 - - - 16A 36.0 - - - - 7.8 - - - 17 36.0 - - - - 15.5 - - - 101 36.0 K= 4.90 7.6 13.5 102 36.0 K= 4.90 7.0 13.0 201 36.0 - - - - 15.5 - - - 202 36.0 - - - - 15.5 - - - 195 25.0 - - - - 19.8 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(2HD).SDF JOB TITLE: GARFIELD RESIDENCE PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.5 0.995 PL 15.00 PF 5.7 1 0.0 SRCE 55.9 (N/A) 13.0 150 FTG TG PE 0.0 2 0.0 0.0 50.2 0.0 0.258 TL 22.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 50.2 0.0 4.0 psi, 31.5 gpm 2A 0.0 0.0 46.2 0.0 Pipe: 3 31.5 1.025 PL 2.00 PF 0.4 2A 0.0 0.0 46.2 0.0 12.2 150 FTG ---- PE 0.0 D 0.0 0.0 45.7 0.0 0.223 TL 2.00 PV Pipe: 4 FIXED PRESSURE LOSS DEVICE D 0.0 0.0 45.7 0.0 5.0 psi, 31.5 gpm C 0.0 0.0 40.7 0.0 Pipe: 5 31.5 1.025 PL 2.00 PF 1.1 C 0.0 0.0 40.7 0.0 12.2 150 FTG E PE 0.0 2B 0.0 H.S. 39.6 5.0 0.223 TL 5.00 PV Pipe: 5A 26.5 1.025 PL 2.00 PF 0.3 23 0.0 H.S. 39.6 5.0 10.3 150 FTG ---- PE 0.0 2C 0.0 0.0 39.3 0.0 0.162 TL 2.00 PV Pipe: 6 26.5 1.610 PL 70.00 PF 1.5 2C 0.0 0.0 39.3 0.0 4.2 150 FTG 2E PE 0.0 3A 0.0 0.0 37.8 0.0 0.018 TL 85.00 PV Pipe: 7 26.5 1.265 PL 7.00 PF 0.8 3A 0.0 0.0 37.8 0.0 6.8 150 FTG 2E PE -2.2 3B 5.0 0.0 34.9 0.0 0.058 TL 13.00 PV Pipe: 8 26.5 1.394 PL 2.00 PF 0.1 33 5.0 0.0 34.9 0.0 5.6 150 FTG ---- PE -0.9 3 7.0 0.0 33.9 0.0 0.036 TL 2.00 PV Pipe: 9 26.5 1.380 PL 2.00 PF 0.1 3 7.0 0.0 33.9 0.0 5.7 120 FTG ---- PE -0.9 4 9.0 0.0 32.9 0.0 0.058 TL 2.00 PV Pipe: 10 FIXED PRESSURE LOSS DEVICE 4 9.0 0.0 32.9 0.0 3.0 psi, 26.5 gpm 4A 9.0 0.0 29.9 0.0 Pipe: 11 26.5 1.394 PL 17.00 PF 1.7 4A 9.0 0.0 29.9 0.0 5.6 150 FTG 3ET PE -2.2 5 14.0 0.0 26.1 0.0 0.036 TL 47.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HD) .SDF JOB TITLE: GARFIELD RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12 16.8 1.394 PL 8.00 PF 0.4 5 14.0 0.0 26.1 0.0 3.5 150 FTG 2E PE -0.4 6 15.0 0.0 25.3 0.0 0.016 TL 24.00 PV Pipe: 13 9.7 1.394 PL 11.00 PF 0.2 5 14.0 0.0 26.1 0.0 2.0 150 FTG 3T PE 0.0 7 14.0 0.0 25.9 0.0 0.006 TL 29.00 PV Pipe: 14 9.7 1.101 PL 17.00 PF 0.6 7 14.0 0.0 25.9 0.0, 3.3 150 FTG E2T PE 0.0 8 14.0 0.0 25.3 0.0 0.018 TL 34.00 PV Pipe: 15 16.8 1.394 PL 15.00 PF 0.6 6 15.0 0.0 25.3 0.0 3.5 150 FTG 2ET PE -4.3 9 25.0 0.0 20.3 0.0 0.016 TL 37.00 PV Pipe: 16 9.7 1.101 PL 19.00 PF 0.8 8 14.0 0.0 25.3 0.0 3.3 150 FTG 2E2T PE -4.8 13 25.0 0.0 19.8 0.0 0.018 TL 43.00 PV Pipe: 17 16.8 1.394 PL 2.00 PF 0.1 9 25.0 0.0 20.3 0.0 3.5 150 FTG T PE 0.0 10 25.0 0.0 20.2 0.0 0.016 TL 8.00 PV Pipe: 18 16.8 1.101 PL 14.00 PF 1.7 10 25.0 0.0 20.2 0.0 5.7 150 FTG 4T PE 0.0 11 25.0 0.0 18.5 0.0 0.049 TL 34.00 PV Pipe: 19 -9.7 1.101 PL 2.00 PF 0.1 11 25.0 0.0 18.5 0.0 3.3 150 FTG T PE 0.0 12 25.0 0.0 18.7 0.0 0.018 TL 7.00 PV Pipe: 20 -9.7 1.101 PL 29.00 PF 1.1 12 25.0 0.0 18.7 0.0 3.3 150 FTG E5T PE 0.0 13 25.0 0.0 19.8 0.0 0.018 TL 61.00 PV Pipe: 21 0.0 1.394 PL 15.00 PF 0.0 10 25.0 0.0 20.2 0.0 0.0 150 FTG 2ET PE -4.8 14 36.0 0.0 15.5 0.0 0.000 TL 37.00 PV Pipe: 22 26.5 1.101 PL 26.00 PF 5.1 11 25.0 0.0 18.5 0.0 8.9 150 FTG 2ET PE -4.8 16 36.0 0.0 8.6 0.0 0.114 TL 45.00 PV Pipe: 23 0.0 1.101 PL 15.00 PF 0.0 12 25.0 0.0 18.7 0.0 0.0 150 FTG 2ET PE -4.8 15 36.0 0.0 13.9 0.0 0.000 TL 34.00 PV Pipe: 24 0.0 1.101 PL 21.00 PF 0.0 14 36.0 0.0 15.5 0.0 0.0 150 FTG 4T PE 0.0 17 36.0 0.0 15.5 0.0 0.000 TL 41.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE(2HD) .SDF JOB TITLE: GARFIELD RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 26.5 1.101 PL 2.00 PF 0.8 16 36.0 0.0 8.6 0.0 8.9 150 FTG T PE 0.0 16A 36.0 0.0 7.8 0.0 0.114 TL 7.00 PV Pipe: 26 13.5 1.101 PL 1.00 PF 0.3 16A 36.0 0.0 7.8 .0.0 4.5 150 FTG E PE 0.0 101 36.0 4.9 7.6 13.5 0.033 TL 8.00 PV Pipe: 27 13.0 1.101 PL 12.00 PF 0.8 16A 36.0 0.0 7.8 0.0 4.4 150 FTG 2E PE 0.0 102 36.0 4.9 7.0 13.0 0.031 TL 26.00 PV Pipe: 28 0.0 1.101 PL 8.00 PF 0.0 17 36.0 0.0 15.5 0.0 0.0 150 FTG 2ET PE 0.0 201 36.0 0.0 15.5 0.0 0.000 TL 27.00 PV Pipe: 29 0.0 1.101 PL 8.00 PF 3.0 201 36.0 0.0 15.5 0.0 0.0 150 FTG 5E PE 3.0 202 36.0 0.0 15.5 0.0 0.000 TL 43.00 PV Pipe: 30 0.0 1.101 PL 1.00 PF 0.0 13 25.0 0.0 19.8 0.0 0.0 150 FTG E PE 0.0 195 25.0 0.0 19.8 0.0 0.000 TL 8.00 PV NOTES (HASS): Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 16080621 granted by HRS Systems, Inc. - 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.131 gpm. Total pressure at each node is used in balancing, the system. Maximum water velocity is 13.0 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 62.93 psi compared to the minimum required pressure of 20.00 psi. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HD) .SDF JOB TITLE: GARFIELD RESIDENCE (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPViv NPTee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli Tee LngEil ChkVlv BfyVlv GatVlv NPTee 1.610 7.50 8.00 2.10 0.00 0.00 0.00 0.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E T R K C 45 El Tee RunT Kplq ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 1.394 2.00 8.00 6.00 1.00 1.00 11.00 3.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Eli TeeRun Koupig ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Koupig ChkVlv GatVlv NPTee 1.025 3.00 7.00 1.00 2.00 0.00 7.00 0.00 7.00 1.265 3.00 6.00 1.00 2.00 0.50 7.00 0.00 6.00 70.0 G A 60.0 U G E jwt P R E S 40.0 S U R 30.0 E 20.0 S F 1 10.0 ME -14.7 WATER SUPPLY ANALYSIS Static: 63.00 psi Resid: 54.00 psi Flow: 500.0 gpm FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 11/10/2016 Z:\DERIK\DERIK CALC\GARFIELD RESIDENCE (2HD) .SDF JOB TITLE: GARFIELD RESIDENCE WATER SUPPLY CURVE 72+ 66+ I \\\ 60+ \\\ I \\\ x \\\ 54+ * <-54.0 psi 8 500 gpm I Flow Test Point P 48+ R I E I S I S 42+ U I R I E I. 36+ P I S I I 30+ 24+ 18+ 12+ LEGEND I X = Required Water Supply I 55.87 psi 8 31.5 qpm 6+ I 0 = Available Water Supply I 62.95 psi 0 31.5 gpm U +------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) B________ A G AlIF /1 IL LLL1 Sizes: 03/4" U 1" U 1-1/4" U 1-1/2" U 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 OPTIONS (Suffixes can be combined) U - with full port QT ball valves (standard) U L - less ball valves U U - with union ball valves U S - with bronze "Y" type strainer U TCU - with test cocks "vertical" up U V - with union swivel elbows (3/4" & 1") U OSY - with OS & Y gate valves U FDC - with fire hydrant connection (2" only) U FT - with integral male 45° flare SAE test fitting APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (All sizes approved horizontal Vérticãl approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical I 1/4"-2"). CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4") City of Los Angeles Approved (vertical 1-1/411-2") NYC MEA426-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASIM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U OT-SET Quick Test Fitting Set U Test Cock Lock (Model TCL24) FBI DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS (approximate WEIGHT MODEL A UNION B LESS BALL LESS WITH SIZE A BALL VALVES C D E F G BALL BALL VALVES . VALVES VALVES in. I mm in. mm in, mm in. mm in. Imm in. Imm in. mm in. I mm in. I mm lbs JL lbs. jg 3/4 20 111/4 2861 121/2 318 7 178 11/2 38 3 76 31/2 89 3 1 76 15 381 5 2.3 7 3.2 1 25 1121/4 311 137/8 353 7 178 11/2 38 3 76 31/2 89 3 76 173/4 451 8 3.6 12 5.4 11/4 32 151/2419 181/2 470 109/16 268 2 51 3 1/2 89 4 1/2 114 41/2 114 211/2 546 16 7.3 22 10 11/2 40 171/8435 191/8 486 109/16 268 2 51 31/2 89 41/2 114 41/2 114 223/4 578 16 7.3 22 10 2 50 18.1/4 460 20 508 109/16 268 2 51 31/2 89 41/2 114 41/2 114 251/8 638 16 7.3 28 112.7 Page 1 of 2 WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805-238-7100 Fax:805-238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11-2 Phone:905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222-5356) Website: http://www.zurn.com 1. 12.6 15.8 Tgo Mill- FLOW CHARACTERISTICS MODEL 950XL 314", 1", 11/4",111/2" & 2" (STANDARD & METRIC) FLOW RATES (Ifs) FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. OUTDOOR INSTALLATION Capacity thruSchedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 1 63 95 52 78 1 105 167 I p DIRECTION OF FLOW INDOOR INSTALLATION SPECIFICATIONS The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed NoryITM and the seat disc elastomers shall be silicone. The first and second checks shall be acces- sible for maintenance without removing the device from the line. The Double Check Valve Backflow Preventer shall be a WILKINS Model 950XL. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805-238-7100 Fax:805-238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222-5356) Website: http://www.zum.com Page 2 of 2 ii! Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi National Fire Products, LLC R ES I - RISERTM The RESI-RISERTM is a pre-assembled, compact, attractive fire sprinkler riser unit for residential sprinkler systems in accordance with NFPA 13, 13R and 13D. The RESI-RISERTM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESI-RISERTM to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet. Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPDT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESI-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESI-RISER fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 1W', 1W', and 2" Style: Thread xThread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent U 6,076,545 RESI-RISERTM Size Chart Description 1" 1W' 1W' 2" Height* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2" Depth 3-1/2" 3-1/2" 3-1/2" 3-1/2- Drain Size 1/2" 1" 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve © National Fire Products, LLC (800) 528-7978 Pressure Loss Tables Pressure Loss in 1" Resi-Riser 12 Relieving Pressure Exceeding 175 psi 15 10 CL 8 w '-6 0.0 0 10 15 20 25 30 35 40 Flow (gpm) Pressure Loss in 1-1/4" Resi-Riser 10 8 6 4 --- - 0 10 15 20 25 30 35 40 45 50 55 60 Flow (gpm) Pressure Relief/Test and Drain How it Works L Normal Position - Static Pressure 'U Manual Open - Drain or Flow Switch Test Pressure Loss in 1-1/2" Resi-Riser 0 l4-4-4-4-4-1--4-4-4-4-4-+-1 0 10 15 2025 30 35 4045 5055 60 65 70 75 80 Flow (gpm) Pressure Loss in 2" Res!-Riser Locked Closed for Hydrostatic Test 6 . 5 a) 0 15 25 35 45 55 65 75 85 95 Flow (gpm) © National Fire Products, LLC (800) 528-7978 Fl Res30,49,58&76 Fl Res30,49,58&76 Recessed Pendent / Fl Recessed Pendent / FP Fl Res 30, 49, 58 & 76 Fl Res 44&58 Fl Res 44SWC CCP Pendent Recessed HSW/F2 Bulletin 135 Rev. M Model F1 Residential Sprinklers for Design Density of .05 gpm4t2 Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpmiIt2 Types: Fl Res 30 Pendent Fl Res 30 Recessed PendentJF2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/F1 Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed PendentJFl Fl Res 58 Recessed Pendent/FP Fl Res 76 Pendent Fl Res 76 Recessed Pendent/F1 Fl Res 76 Recessed PendentJFP Fl Res 30 CCP Pendent Fl Res 49 CCP Pendent Fl Res 58 CCP Pendent Fl Res 76 CCP Pendent Fl Res 44 HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSWX KRes58 HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44 SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewal sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residenal market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: ½' NPT (R½) K-Factor: ao (432) (Actual)- Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (85) (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent SpnWer 4.4(63) (Actual) -Fl Res 14 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl Res 30 Recessed Pendent I F2 Model Fl Res 30, 49, 58 &76 Pendent • Mod S 49, 58 & lb mecessea Pen lent/Fl Application Model Fl Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 130, 13R, or 132013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*. Fl or F2. Data: the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model 0 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and 'Top" mark- ing must face ceiling. Type Adjustment 'A" Face of fitting to ceiling Deflector Distance below bottom of beam Inch (mm) Inch (mm) Inch (mm) Inch (mm) Fl 3/4 (19.0) Min. Recessed = 1/6 (41.3) 3/,(9.5) 13/4 (44.4) Max. Recessed =7/s (22.2) 11/8(28.6) 1(25.4) F2 1/2 (12.7) Min. Recessed = 1/8 (41.3) /8 (9.5) 13/4 (44.4) Max. Recessed =11/8 (28.6) 7/,(22.2) 11/4 (31.7) * Note: Escutcheons Fl or F2 may be used with Model Fl Res 49, 58 & 76 Recessed Pendent Sprinkler - Fl escutcheon, 3/4" (19mm) adjustment 2 114 -HOLE 054.1 I-..- (57.2mm] -..-.l _JJ I I5/I6 054. I I [49.2mm] I TURN COLLAR UNflL : [FACE OF FITTING TO r 1 CEILING DIMENSION _X I/ REDUCER AVENCH BOSS. - J 3/8'-7/8 (F2 ESCUTCHEON) 3/8— I 1/8 (Fl ESCUTCHEON) ADJUSTMENT I i 2 27/32 D5 [52mm] (72.2mm] Fig. 1 Fig. 2 Technical Data: F1 Res 30 Pendent and Recessed Pendent (SIN R3511) Thread I Nominal Orifice Max. Pressure iSprinkler Temp. Rating I Max. Ambient Tem. I Actual K I Sprinkler Length I J OF I °C I OF I °C Size I Inch (mm) osi (bar) I Factor IInch (mm) I 1/2" NPT (RV2) I 21/64' (8.2) I 175 (12) 155 175 68 79 100 I 38 I 3.0 (43.2) I I 2.25 (57) I Max. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Spacing (155°F168°C) (175°Ft790C) Top of Deflector to Celing Spacing Ft x Ft (m x m) Ft (m) Flow Pressure Flow Pressure Inch (mm) Ft (m) GPM (Llmin) P (bar) GPM (1/mm) PSI (bar) 12 x 12(3,6 x 3,6) 12(3.6) 8(30,3) 7.0 (0,48) 8(30,3) 7.0(0,48) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14x 14(4,3x4,3) 14(4,3) 10(37,8) 11(0,76) 10(37,8) 11(0,76) Beamed CeIings per NFPA 13D, 13R 8(2,4) or 13 installed in beams 11/4 to 13/416 X 16 (4,9 X 4,9) 16 (4,9) 13 (49) 18.8 (1,3) 13 (49) 18.8 (1,3) (31.7 to 44.4) using F2 escutcheon For Ceilina Woes refer to NFPA 13. 13R or 13D 2. Technical Data: Fl Res 49 Pendent and Recessed Pendent (SIN R3516) Thread I Nominal Orifice I Max. I Pressure I Sprinkler I Max. I Actual I Sprinkler I Size Inch (mm) I Temo. Ratina I K I Length I I I psi (bar) °F I °C I =OF I Factor I Inch (mm) I ½" NPT (R½) I I 7/iS" 11 175(12) 155 175 68 79 I (70.6) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°Fi8°C) (175°F1790C) to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (mx m) Ft (m) GPM (Lh,ln) PSI (bar) GPM (L/min) PSI (bar) Inch (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 13(49) 7.0 (0,48). 13 (49) 7.0(0,48) Smooth Ceilings 11/4 to 4 (31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0(0,48) 13(4 . 9) 7.0 (048) 1 t 4(25.4 to 102) using Fl escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 13 (49) 7.0 (0,48) 13 (49) 7.0(0148) Beamed Ceilings per NFPA 13D, 138 or 13 installed in 8 (24) 18 x 18(5,5 x 5,5) 18(5,5) 17 (64,3) 12(0,83) 17 (64,3) 12(0,83) beams 11/4 to 13 (31.7 to 44.4) using F2• escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20 (75,7) 16.7(1,14) 20 (75,7) 16,7(1,14) to 13A (25.4t044.4)using Fl escutcheon For Ceiling types refer to NFPA 13, 138 or 13D Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°Fi8°C) (175°F1790C) to Ceiling spacing Flow Pressure how Pressure Ft x Ft (mx m) Ft (m) GPM (L.knin) PSI (bar) (3PM (LAnin) PSI (bar) Inch (mm) Ft (m) 12 x 12 (3,6 x 36) 12(3.6) 15 (57) 9.4 (0,65) 15(57) 9.4 (0,65) Smooth Ceilings 4 to 8 (100 to 203) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6 (0,73) 16(60,5) 10.6 (0,73) 4 t 8(100 to 203) using Fl escutcheon. 16 x 16(4,9 x ,9) 16(4,9) 17(64,3) 12.0(0,83) 17(64,3) 12.0 (0,83) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 18x 18(5,5x5,5) 18(5,5) 19(72) 15.0(10) 19(72) 15.0(1,0) 4¼t08(108t0203) using F2 escutcheon, 4 to 8(100 to 203) 20 X 20 (6,1 X 6,1) 20(6.1) 22 (83,2) 20.2 (1,4) 22 (83,2) 20.2 (1,4) jusing Fl escutcheon Technical Data: Fl Res 58 Pendent and Recessed Pendent (SIN R3513) Thread. I Nominal Orifice I Max. I Sprinkler I Max. I Actual I I Sprinkler I Size I Inch (mm) Pressure Temp. Rating I Ambient Temp, I K Factor Length I I I OF I °C I OF °C I psi (bar) I I Inch (mm) I ½" NPT (81/2) 1/2-(13) I 175 (12) 155 175 68 79 100 150 38 66 I 58 (.5) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (l55°F,8°C) (1750F/790C) to Ceiling spacing Flow Pressure Flow Pressure Ft x Ft (mx m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) P (bar) GPM (1/mm) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 16 (61) 7.6(0,53) 16 (61). 7.6 (0,53) Smooth Cehings 11/4 to 4 (31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) 16(61) 7.6 (0,53) 1 t 4 (25.4t0 102) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) 16(61) 7.6 (0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19 (72) 10.8 (0,75) 19(72) 10.8 (0,75) 11h to 1/4 (31.7 to 44.4) using F2 escutcheon, 1 t 13/4 (25.4 to 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 44.4)using Fl escutcheon For Ceiling types refer to NFPA 13, 138 or 13D 3. Technical Data: Fl Res 76 Pendent and Recessed Pendent (SIN R7618) Thread Nominal Orifice Max. I Sprinkler I Max. I I K Sprinkler Size Inch (mm) Pressure Temp. Rating Ambient Temp. Factor Length I I I C I °F I °C I Psi (bar') Inch (mm') I 3/4 NPT 17/32" (13.5) 175 (12) 155 175 68 79 100 150 I 38 I I 66 I 7.6(109) 2.25 (57) I Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing (155eF,8*C') (1750171790C) Top of Deflector to Ceiling Spacing Flow Pressure Flow GPM Pressure FIx Ft (mx m) Ft (m) Inch (mm) GPM(L/min) PSI (bar) (L/min) PSI(bar) 12 x 12 (3,6 x 3,6) 12(3,6) 21(79,5) 7.6 (0,53) 21(79,6) 7.6 (0,53) Smooth Ceilings 41/4 to 8(108 o 203) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21(79,5) 7.6 (0,53) 21(79,5) 7.6 (0,53) 4 to 8(100 to 203) using Fl escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 21(79,5) 7.6(0,53) 21(79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 21(79,5) 7.6 (0,53) 21(79,5) 7.6 (0,53) beams 414 to 8(108 to 203) us- ng F2 escutcheon, 4 to 8 (100 20 x 20 (6,1 x 6,1) 20(6,1) 23 (87,1) 9.2 (0,63) 23 (87,1) 9.2 (0,63) to 203) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D M/ )aei i-i iies su, 4, & lb uur ii-en N * Not listed for corrosion resistance. Jent* • Model Fl Res 30, 49, 58 & 76 Recessed Pendent/ FP FP push-on/thread-off escutcheon 2 5/8 [66.7mm] 014. 2 5/16 0/A. HOLE IN CEILING [58.7mm] CUP I x 1/2" REDUCER CUP CEILING 1 1/4" /31.5mm] MAX FACE OF FITTING TO FACE OF CEILING ' DIMENSION COVER ADJUSTMENT HEIGHT .3 5/16' 0/4. I35FG04E [84. Irnm] - Fl RES 30, 49, 58 & 76 CCP PEND. Fig. 3 Note: The Fl Res 76 will use a 1" x 34" reducer. CCP Cover Plate Data: Cover Adjustment CCP Height c Deflector Distance bow bottom Inch (mm) Inch (mm) of beam Inch (mm) 1/2 (12.7) 15/76 (24) 1/2(13)_i (25.4) s/is (7.9) 3/4 (19) ½ (13) -1 (25.4) 2 5/8" DIA. (66.7mm] -HOLE IN CEILING- 2 5/16" 0/A. - [58 7--] —1 CLIP I _L_J, 1"X 1/2" REDUCER S I I I / 1 1/2"1(38.lmm] MAX. _______ FACE OF FITTING ________ TO FACE OF CEILING CEILING_ ______ 1/2" [13mm] M4X1 Of/lENS/ON A" FP ADJUSTMENT Fl RES 49 PENDENT/FP Fig. 4 FP Escutcheon Data: FP Position "A" Deflector Distance below bottom Inch (mm) of beam ____ Inch (mm) Max Recessed /is(11) ½(12.7) Mm. Recessed .15/16(24) 1 (25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. 4. Technical Data: Fl Res 30 COP Pendent and Recessed Pendent/FP (SIN 143511) Thread Nominal I Max. COP Assembly I Max. I K I Sprinkler Size Orifice I Pressure Team. Ratina I Ambient Temp. I Factor Length OF °C J OF °C Inch (mm) I psi (bar) Inch (mm) 1/2"NPT (R½) 2I/" (8.2) 175 (12) 135 57 100 38 3.0 (43.2) 2.25 (57) Ordinary Temp. Rating Minimum Max. Coverage area Max. Spacing (1550F/680C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) PSI (bar) - Smooth Ceilings ½ to 1(13 to 25.4) using CCR 12 X 12 (3,6 X 3,6) 12(3,6) 8(30.3) 7.0(0,48) ½ to 1(131025.4) using FR escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 14x 14(4,3x4,3) 14(4,3) 11(37,8) 13.4(0,92) beams Y2 to 1(13 to 25.4) using CCP. ½ to 1(13 to 25.4) using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 130 Technical Data: Fl Res 49 COP Pendent and Recessed Pendent/FP (SIN 3516) Nominal Max. CCP Max. Assembly Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size Inch psi (bar) Rating Temp. Factor Inch (mm) (mm) °Fl°C OF 1°c /2"NPT (R1/2) /16" (11) 175 (12) 135 I 57 1001 I 38 4.9 (70.6) 2.25 (57) Max. coverage Ordinary Temp. Rating Minimum area Max. Spacing (155. -C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) Smooth Ceilings ½ to 1(131025.4) using 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0 (0.48) CCR /2 to 1(131025.4) using FR escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 14 (53) 8.2(0,56) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68,1) 13.5 (0,93) OCR V2 to 1(13 to 25.4) using FR escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7 (1,14) For Ceiling types refer to NFPA 13, 13R or 130 Technical Data: Fl Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Thread I Nominal I Max. I CCP Assembly I Max. K I Sprinkler I Size I Orifice i Pressure Temp. Rating Ambient Temp, I Factor Length I I OF I °C Inch (mm) psi (bar) I (R½) I /2"(13) 175(12) I I 135 Inch (mm) 1/2,,NPT I If*OF f38 I 5.8 (83.5) 2.25 (57) Max. coverage Ordinary Temp. Rating Minimum area Max. Spacing (155' -C) Top of Deflector to Ceiling Spacing Flow Pressure FtxFt(mxm) Ft (m) Inch (mm) - Ft (m) GPM(LM'iin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) Smooth Ceilings ½ to 1 (1 3 to 25.4) using COP. Y2 to 1(13 to 25.4) using FR escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams 1/210 1(13 to 25.4) using OCR 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 19 (72) 10.8 (0,75) ½ to 1(13 to 25.4) using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13R or 130 5. F2 escutcheon, 1/2" (1mm) adjustment Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Nominal I Max. I CCP Assembly Max. I Sprinkler I Thread Size Orifice I Pressure Temp. Rating Ambient Temp. I K I Factor I I Length I °F C °F I Inch (mm) I psi (bar) I I Inch (mm) I 3/4" NPT 17/32" (13.5) I 100 175 (12) 135 f57 I 38 I 66 7.6(109) 2.25(57) 150 Max. coverage Ordinary Temp. Rating MinimumMinimum area Max. Spacing (155°Fi8°C) Top of Deflector to Ceiling Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Lknin) P (bar) 12 x 12(3,6 x 3,6) 12(36) 21(79,5) 7.6(0,53) Smooth Ceilings 1/2tol(13t025.4) using CCP. /2 to 1(13 to 25.4) using FP escutcheon.- 14x 14(4,3x4,3) 14(4,3) 21(79,5) 7.6(0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 21(79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 22 (83,3) 8,4 (0,58) 1/2 to 1(13 to 25.4) using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 25(94,6) 10.8 (0,74) For Ceiling types refer to NFPA 13, 13R or 13D Model F1 Res 44&58HSW FACE OF FInING TO WALL DIMENSION 2 1/4 HOLE 014. [512mm] x I/2 REDUCER "L [.318mrr3 1/8 CEILING TO [3.2mm] DEFLECTOR DIMENSION Model Fl Res 44 & 58 Recessed HSW/F2 I I5 /16 - I [49.2m 2 27/32- 0/k [72.2mm] TURN COLLAR UNTIL A G4INST SPRINKLER WRENCH BOSS, 112- f [13mm] ADJUSTMENT Fl RES 58 & 44 HSW/F2 Fig.5 - Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Size Orifice Pressure Temp. Rating Temp. - Factor Length Inch (mm) psi (bar) Inch (mm) °F DFIOC ½"NPT (Rh) J? (10) 175 (12) 155 100 -175 150 ff79 I 38 I 66 4.4(63) 2.45(62) Escutcheon, F2, Data: Face of Fitting Type Adjustment Inch (mm) to wall Inch (mm) F2 '/2(13) /I6 - 11/16 (4.7-17.4) [1 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F,80C) Intermediate Temp. Rating (175°F/790C) Top of Deflector to Ceiling (mm) Spacing Inch Minimum Ft (m) now GPM (LhTiin) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,6 x 36) 12(3.6) 12(45,4) 7.5 (0,52) 12(45,4) 7.5 (0,52) 4 to 6(100 to 152); 1/2 (13) recessed using F2 escutcheon 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 14(53,0) 10.2(0,71) 14(53,0) 10.2(0,71) 16 X 16(4,9 X 4,9) 16(4,9) 16(60,6) 13.3 (0,92) 16(60,6) 13.3(0,92) 16 x 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8(1,16) 18(68,1) 16.8 (1,16) 18 x 18(5,5 x 5,5) 18(5,5) 19 (72,0) 18.7(1,29) 19 (72,0) 18.7 (1,29) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4 (1,89) 23(87,1) 27.4 (1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(53,0) 10.2 (0,71) 14(53,0) 10.2 (0,71) 6t0 12 (152 to 305); 1/2 (13) recessed using F2 escutcheon 14 x 14 (4,3 x 4,3) 14(4,3) 16(60,6) 13.3(0,92) 16 (60,6) 13.3 (0,92) 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,4) 15.0 (1,04) 17(64,4) 15.0 (1,04) 16 x 18 (4,9 x 5,5) 16(4.9) 20(75,7) 20.7 (1,43) 20 (75,7) 20.7 (1,43) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4 (1,89) For Ceiling types refer to NFPA 13J3R or 13D Technical Data: Fl Res 58 HSW & HSWIF2 (SIN R3533) Escutcheon, F2, Data: Nominal Max Sprinkler - Max. Sprinkler Ambient K Length Adjustment Face of Fitting Thread Orifice T ype to wag Pressure Temp. Rating Temp. Factor Inch Itch (mm) Size Inch _____ Inch (mm) psi (bar) ° OF I °c (mm) (mm) °F /16 - 11/16 ½'NPT 155 68 100 I 38 F2 1/2 (13) 1/2" (13) 175 (12) 5.8(83.5) 2.45(62) (4.7-17.4) I (R½) 175 79 150 I 66 - Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (155°FI8°C) (175°F/79°C) Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(60,6) 7.6(0,53) 16(60,6) 7.6 (0,53) 4 to 6 ( 100 to 152); 14x 14(4,3x4,3) 14(4,3) 18(68,2) 9.7 (0,69) 18(68,2) 9.7 (0,69) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 13.2 (0,91) 21(79,5) 13.2(0,91) ½ (13) recessed using F2 escutcheon 16 x 18 (4,9 x 5,5) 16(4,9) 25(94,7) 18.6(1,28) 25(94,7) 18.6(1,28) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 29(109,8) 25.0(1,73) 29(109,8) 25.0 (1,73) 12 x 12(3,6 x 3,6) 12(3,6) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 6 to 12 (152 to 305); ½(13) recessed 14 x 14(4,3 x 4,3) 14(4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 16 x 16 (4,9 x 4,9) 16(4,9) 26(98,4) 20.1 (1,39) 26 (98,4) 20.1 (1,39) using F2 escutcheon 16 x 18 (4,9 x 5,5) 16(4,9) 31(117,4) 28.6(1,97) 31(117,4) 28.6 (1,97) For Ceiling types refer to NFPA 13 13R or 13D 7. Model Fl Res 44 SW* * Not listed for corrosion resistance. TrThnitl flit Fl Rae AA czwr (siN P1i 4to12 [10130mm To I I/4 j3L75mr,,J Io*Imm, -l-----F 304.80mm] Fa~ Of TO Wag Um- PLSH URA( 70 AaWT UNIX 1XI/R.tho., R.00mmnd.d 2 5/16 - fmrnj - tea oij - DIM Dk, lURk COW.R UNTIL 4,aSPRJNIa.FR I4z2 nJ - 112' [C.70MMI Fl RES 4.4 SWC Fig. 6 Nomiral Max. Cover Max. K Sprinkler Thread Orifice Pressure T. Ambient . Length Size Inch (rrm) psi (bar) Rat,rq I Temp. Factor Inch (mm) W'NPT 3/811 (10) 175 (12) 135 57 30 38 4.4(63) 2.45 (62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinarj Temp. Rating (l.:5 F.'6 C) Top of Deflector to Ceiling Inch 'mm' ' Minimum Spacing Ft m Flow GPM (limir:i Pressure PSI (bar) 12 x 12(3,6 x 36) 12(3,6) 13 (_49,2)- 8.7 (0,60) 4 to 6(100 to 152); 1/2 (13) recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 43) 14(4,3) 14(5.3)) 10.2(071) 16 X 16(4,9 X 49) 16(4,9) 1 (643) 15.0(1,1) 16 x 18 (4,9 x 5,5) 16(4,9) 1(71B) 18.7(113) 16 x 20 (4,9 x 6, 1) 16(4,9) 23 (0-7:1) 27.4(189) 12x 12(3,6x3,6) 12(3,6) 4 (E2.5) 10.2(0,71) 6to 12(15210 305); ½ (13) recEssed using F2 escutcheon 14x 14(4,3 x 43) 14(4,3) 5 () 11.7 (0,81) 16 x 16(4,9 x 4,9) 16(419) 16 (68.1) 16.3 (1,16) 16 x 18(4,9 x 55) 16(419) 20(75,E) 207(143) For Ceiling types refer to NFPA 13, 13R or I 3D 1 15/76" O14.4JJ34 (49.2mm] 2 27/32" 014. [72.2mm] TURN COLLAR UNTIL Ln TIGHT AGAINST SPRINKLER WRENCH BOSS. - ADJUSTMENT Fl RES 58 HSWX Fig. 7 Technical Data: Fl Res 58 HSWX (SIN RA3533) Nominal Max. Sprinkler Max. Sprinkler Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Identification Size Inch (mm) psi (bar) Temp. Factor Inch (mm) Number (SIN) OF 1°c OFiOC Bulb /2NPT 1/2 (13) 175(12) 155168 175 I 79 100 150 I 1 5.8 (83.5) 2.45 (62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/680C) Intermediate Temp. Rating (175°F/790C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 18 x 20(5,5 x 6,1) 18(55) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4t06(100to 152); 1/2(13) recessed using F2 escutcheon 8(2,4) 20 x 20 (6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 16 x 22(4,9 x 6,7) 16(4,9) 33 (125) 32.4 (2,23) 33(125) 32.4(2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14(4,3) 42(160) 52.4 (3,75) 42(160) 52.4(3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9(2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42 (160) 52.4(3,6) 42(160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14(4,3) 46 (174) 62.9 (4,34) 46(174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 58 HSWX (Bulb) Model KRes58 HSWX (Link) FACE OF FITTING TO WALL DIMENSION 2 7/4" HOLE 0/A [57.2mm] X 7/2" REDUCER VA 1 11/I6MIN. I [31.8mm] II A CEILING TO [3.2mm] DEFLECTOR DIMENSION .,, Technical Data: KRes58 HSWX (RA3593) Nominal Max. Max. Sprinkler Sprinkler Thread Orifice Pressure Ambient K Length Identification Size Inch (mm) psi (bar) Temp. Factor Inch (mm) Number (SIN) OF Link ½" NPT (R½) 1/2" (13) 175 (12) 100 38 5.8 (83.5) 245 (62) RA3593 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165- 0C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Llmin) Pressure PSI (bar) 18 x 20(5,5 x 6,1) 18(5,5) 29(109) 25(1,72) 4 to 6(100 to 152); ½ (13) recessed using F2 escutcheon 8(2,4) 20x20(6,1 x6,1) 20(6,1) 30(114) 26.8(1,85) 16 x 22(4,9 x 7,3) 16(4,9) 33 (125) 32.4(2,23) 16 x 24(4,9 x 7,3) 16(4,9) 38 (144) 42.9 (2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42 (160) 52.4 (3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 6 to 12 (152 to 305); ½ (13) Recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38 (144) 42.9 (2,96) 16 x 24(4,9 x 7,3) 16(4,9) 42 (160) 52.4(3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46 (1 4) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and Fl Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturers installation guide.- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for FlRes 49. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model Fl Res 30,49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30,49 & 58 Recessed Pendent/ F2, Model Fl Res 30,49 & 58 Recessed Pendentl FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be l"to 8" maximum, only for Fl Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded "DuPont Registered Trademark 10. a or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (791C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with 34" adjustment (Model El)] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model Fl Res 30, 49 & 58 Recessed Pendent/El] [Model Fl Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30,49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal as sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mrri glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- "DuPont Registered Trademark 11. leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (740C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model El Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with 1/2" adjustment (Model F2). Standard finish shall be [brass] [bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). Model Fl Res 76 Recessed Pendent/Fl, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpmlft2 over the listed coverage area. Listed flows as specified by the manu- factijrer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (68°C)] [175°F(79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjust- ment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with 1/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model El Res 76 Recessed Pendent/F2] [Model Fl Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1/2" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify].]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1F2FP Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black White Painted Polyester() Coated Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electrcless Nickel PTFE(Teflona))2) Electrcless Nickel PTFE (Teflon) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull Chrome Dull 1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish. *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. flecyded (800) 431-1588 Sales Offices . Paper Rel~lablq:, (800) 848-6051 Sales Fax Revision lass indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ES. Printed in U.S.A. 06/15 P/N 9999970235 Upright Vertical Sidewall Recessed Horizontal Sidewall Horizontal Sidewall Recessed PendenfjF1/F2 Concealed - Recessed Pendent Pendent/FP XLH Upright XLH Pendent Pendent F1/F2 Pendent U.r -, Conventional Bulletin 014 Rev. N Li............ T1 Jflfl' Model Fl FR Series Quick Response Glass Bulb Sprinklers Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1FR56LL & F1FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kIr Underwriters Laboratories Inc. and Certified for Product Description Canada (cULus). Reliable Model Fl FR series sprinklers FM Approvals (FM) are quick-response automatic sprin- Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element. VdS Schad enverhutung GmbH (VdS) Model F1FR series sprinklers are Stan- NJP (rtfir1 tn NSF/AN-Si Standarri 61 Annex i' dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed (NSF) EC Certificate: 0786-CPD-40239 (RA1414), 0786- sprinkler which is an Old-style/Conven- Pendent FP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 (EC) mm frangible glass bulb. These sprinklers have demonstrat- UL Listing Category ed response times in laboratory tests which are five to ten Sprinklers, Automatic & Open (VNIV) times faster than standard response sprinklers. This quick Quick Response Sprinkler response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) - - Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FR recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The• Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or, remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are Open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model Fl FRS6LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN mm Listings and Approvals Approval Notes US - Metric inches mm inches F1FR28 2.8 40 3/8 10 Pendent 2.25 57 D RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 D RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA 1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 1 D RA1410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 225 57 0 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 225 1 57 D RA1423 cULus 1,2 F1 FR56 5.6 80 1/2 15 Pendent 2.25 57 D RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus,S, EC FM, LPCB, Vd 1,2,3,4 Concealed Pendent 225 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 . D RA1425 cULus FM , , LPCB, VdS, EC 1,2,3,4 Conventional (Pendent or Upright) 2.25 57 D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 D RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) . 225 57 0 RA1485 cULus, FM, LPCB 1,2,3,9 ( cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. 3) Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the Fl FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the Fl FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (°) cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The Fl FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the Fl FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector, Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1 07°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) I Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. I Rating Orange Bulb Red Bulb I Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- _________ Upright cULus Pendent VdS F1FR40 Recessed Pendent - VdS I -- Pendent cULus F1FR42 Recessed Pendent cULus I -- _________ Upright cULus Pendent -- cULus, NSF -- F1FR42LL ________ Recessed Pendent -- cULus, NSF -- Pendent cULus F1FRXLH Recessed Pendent cULus I - Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC F1 FR56 Concealed Pendent* cULus I cULus,VdS,EC I cULus -- Upright cULus, FM, LPCB, VdS, EC Conventional (Pendent or Upright)" LPCB EC Pendent -- I cULus, NSF -- F1FR56LL Recessed Pendent -- cULus, NSF -- _________ Concealed Pendent* -- cULus, NSF -- Horizontal Sidewall cULus, FM Fl FR56 _________ Recessed Horizontal Sidewall cULus FM -- F1FR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and El FR56LL Concealed Pendent sprinklers must be used with Reliable Model COP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector/ Orientation Listed and Approved Recessed Escutcheons SIN Model Fl (Fig. 1 & 3) 3/4-inch (19mm) adiustment Model F2 (Fig. 1 & 3) 1/2-inch (12.7mm) adiustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment F1FR28 I Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC cULus, FM, LPCB, VdS,EC cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS ___\\\\\ Fl ESCUTCHEONJ_ 3/4"[l9mmJ ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT 2 1/4" HOLE DL (57.2mm] I 15/16" 014 (49.2mm] L—_—_+---€ LI-------- - Ii \ I I ('1 I. H 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1725.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] 7-7-7-7771 AT MINIMUM RECESS = 3/879.5mm3 l8" 3- A Fl ESCUTCHEON ,1A T AT MAXIMUM RECESS = 7/8722.2mm] 118" 3.2mmj I MINIMUM RECESS = 1-5/8741.3mm./ ( F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8728.6mm] it AT MINIMUM RECESS = 1-5/8741.3mm] 2 27/32" OH. (72.2mm] Fig.l Model Fl FR56, Fl FR56LL, Fl FR42, El FR40, El FR42LL, Fl FRXLH & Fl F1R28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon r 1" X 1/2" REDUCER 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1-1/2738mm] AT MINIMUM RECESS = 1725.4mm] AT MAX/MUM RECESS = 9/16714.3mm./ Y712.7mmj AT MINIMUM RECESS = 1725.4mm] ADJUSTMENT Fig.2 Model Fl FR56, Fl FR561-L, Fl FR42, El ER40,. El FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] -2 1/4" HOLE 0/A. [5 7.2mm] 1" X 1/2" REDUCER - Fl ESCUTCHEON F/A AT MAXIMUM RECESS = 1-3/8734.9mmJ H 7 AT MINIMUM RECESS = 2-1/16752.4mm] V F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8741.3mm AT MINIMUM RECESS = 2-1/16752.4mm] [3.2mm] 1 (1) 4"-12" [101.6mm-304.8mm] 2 27/32" 0/A. CEILING TO [72.2mm] DEFLECTOR Fl ESCUTCHEON [ 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT it 1 15/16" DIA.4.L [49.2mm] it , LL TURN COLLAR UNTIL --- TIGHT AGAINST SPRINKLER WRENCH BOSS. Oi3E RECESSED HSW W/Fl OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW 2 5/8" 0/A. 2 5/16" DIA - ..i HOLE IN CEILING CUP 1 1/2" MAX. FlF951M FACE OF FITTING "1"L liii III 11H To FACE OF CEILING J kt III IJM H DIMENSION CEILING -1 I 1/2" MAX. 15/16" COVER ADJUSTMENT COVER PLATE I ASSEMBLY 3 5/16" 0/A. . SPRINKLER CONCEALED, 1/2" ADJUSTMENT 017Ft01A lRg.4 Model El FR56IF1 FR56LL Concealed Pendent sprinkler with standard oepth 1/2-inch (12.7mm) adjustment - Model CCP cover plate 1" x 1/2" REDUCING TEE OR ELBOW - 2 5/8" DIA. 2 5/16" DIA HOLE IN CEILING CUP - 1 1/2' MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CE/LING- 5/16" MAX. I 3/4" COVER ADJUSTMENT COVER PLATE—'—' ASSEMBLY /3 5/16" DIA. SPRINKLER CONCEALED, 5/16" ADJUSTMENT Fig. 5- Model Fl FR56JF1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover Dlate1 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover platet11 Electroless Nickel PTFE7 Electroless Nickel PTFE Bright Brass Bright Brass13 Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2t6) Black Paint Off White Off White 16 Off White Satin Chrome Chrome Dull Chrome Dull ) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance' applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant 7 Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR40][Fi FR421 [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent][Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch N PT] [ISO 7-R1 /2] Sprinkler Temperature Rating: [135°F (571C)][1551F (68°C)][175°F (79-C)] [200-F (93-C)] [286-F (141°C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by ReHable ®Recycled Paper Revision lines indicate updated or new data. EG, Printed inUS.A. 12/15 P/N9999970300 Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabihets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. 1 OT d SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler. Pendent. Model: RC-RES, K-Factor: 4.9. SIN: S58464 - GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWAs Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARJWNGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities ha ving jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U085160 Date : Feb/09/2015 TECHNICAL DATA Approvals: UlLu. Listed, NSF-61-G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175ps1 (12.1bar) Discharge Coefficient (Nominal K-Factor): K4.9 GPM/psi112 (70.6 LPM/bar112) Temperature Rating: 162F (72°C) Sprinkler with 140'F (60°C) Cover Plate 175'F (79°C) Sprinkler with 162'F (72°C) Cover Plate Color Code (Sprinkler) 167F (7200): Uncolored 175F (790C): White Color Code (Cover Plate) 140'F (60°0): No Mark 162'F (720C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 OPERATION Page :2 of 8 NPT1 /2 2—}(" (52mm) Marking '1 —Lot No. I Year of Manufacture I—SIN : S58464 I—K—factor : K4.9 I—Temperature Rating : 162'F/77C F—UL Mark or 175T/79C N I—Control No. : 6P37 NSF Mark: NSF-61—G_ ERES SPKR (1) Body (Copper Alloy) Deflector (Phosphorus Bronze) - fl Gasket (PTFE) €1 Fusible Metal (Solder) f Heat Collector (Copper) 2— 5/s" (4. 68mm) ti Cover Rote Assembly or 3-Y4" (83mm) or 2— 5/"square (068mm) - FIGURE 1. Model RC—RES K-4.9 COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) 4.9 Rahnq: or 175F/79C In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) PA Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative oumose only) Document No. U085160 Date Feb/09/2015 DESIGN CRITERIA Page 3 of 8 The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. if the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 130 or 13R for the requirements- relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments - The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 130 and 13R as a function of temperature rating and maximum allowable coverage area. Document No. U085160 Date : Feb/09/2015 Page :4 of 8 A minimum discharge 0.1GPM/sq.ft. [4.07LPM/sq.m] over the design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLEA. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 Maximum Ordinary Intermediate Covera ge Maximum Temperature Rating Temperature Rating Deflector Minimum Area Spacing 162'F (720c) 175T (790c) to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ft. Ceiling Type Ft. (rn xm) (m) GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) Smooth 12x12 12 13 7.0 13 7.0 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) 3/8t07/8 Inches. 14x14 14 13 7.0 13 7.0 Beamed (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Ceilings per NFPA 16x16 16 13 7.0 14 8.2 13D,13R Concealed 8 (4.9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) or 13 (2.4) Installed in beam 18x18 18 17 12.0 18 13.5 3/8 to (5.5x5.5) (5.5) (64.3) (0:83) (68.1) (0.93) 7/8 inches 20x20 20 21 18.4 below (6.1x6.1) (6.1) (79.5) (1.27) - - bottom of beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Document No. U085160 Date : Feb/09/2015 Page 5 of 8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.ONm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not fry to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting fora better fit. Installina Procedure Step - - The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Space Here Do NOT Avej' (6.4mm) Over—Tighten Lve n the Sprinkler Mirt ) (3.2mm) 1][JtJ HEI I ____E of Ceiling Level ve CaDeronce LimitC' i1i________________________ ceiling ______ the SocketMounting Surface Mounting Surface Wrench%6Omm) Ceiling Hole Diameter / CORRECT IINC0RRECTI FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No. U085160 Date : Feb/09/2015 b 01 Step Hook by turning Step Pull down FIGURE 5. PROTECTIVE CAP REMOVAL Surfa E E / Deflector! Xover Plate Pssembly 2%"(68mm) 6r3—V4"(83mm) or 3'ssquare (068mm) FIGURE 6 Document No. U085160 Date : Feb/09/2015 Page : 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 T/4 t to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. V If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a tire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds lOOT /38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new, construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA25. Document No. U085160 Date Feb/09/2015 Page : 8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162'F (72°C) or 175'F (79°C)) Cover Plate Assembly: 2-5/8 inch (0 68mm) or 3-1/4 inch (0 83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8" Round, 140°F 0 0 - - - 0 - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - 0 0 3-1/4" Round, 162°F 0 - - - - - - 0 0 Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench & Socket for Model RC-RES Cap Remover RC Document No. U085160 Date : Feb/09/2015