2742 STATE ST; ; FPC2021-0004; Permit
PERMIT REPORT ('7_Cz0f Carlad Print Date: 05/21/2021 Permit No: FPC2021-0004 Job Address: 2742 STATE ST, CARLSBAD, CA 92008-1628 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel U: 2031811900 Track U: Applied: 01/11/2021 Valuation: $556,213.09 Lot U: Issued: 02/04/2021 Occupancy Group: Project U: Finaled Close Out: 05/21/2021 Uof Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check#: Final Inspection: Project Title: Description: WB GAMES -REVISIONS TO NEW NOTIFICATION APPLICANCES & INPUT MODULES FOR DUCT DETECTORS (ALARM TI, 44 DEVICES) Applicant: FPContractor: JJJ ENTERPRISES INC JJJ ENTERPRISES INC DANTE GOMEZ DANTE GOMEZ 115 MARKET PL 115 MARKET PL ESCONDIDO, CA 92029-1353-SAN DIEGO ESCONDIDO, CA 92029-1353 -SAN DIEGO (760) 466-2707 (760) 466-2707 FEE AMOUNT FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Reinspection (per inspection) $193.00 FIRE TI Fire Alarm System $620.00 Total Fees: $949.00 Total Payments To Date: $949.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ENTERPROES '. Velorlop F PC, 2o21 -0004 P.O. BOX 463021 - ESCONDIDO, CALIFORNIA92046-3021 (760)747-3050 - FAX (760)747-7561 City of Carlsbad Fire Department 1635 Faraday Ave. Carlsbad, CA 92008 Project Name: Plan Check/Permit Number: FPC202 1-0004— Fire Alarm Address: 2742-2752 State St. Re: Plan Change The following is a list of plan changes on the approved fire alarm plans. Sheet Item FA-01 Revised fire alarm sequence of operations matrix for pre-action system outputs. FA-01 Updated device counts for strobes and horn/strobes in the device legend. FA-02 Call-out notes and reflected ceiling layout added throughout the floor plan to comply with Architect's concerns. FA-02 A new fire alarm strobe added to provide adequate coverage in the south east corner space of the building. FA-03 Call-out notes and reflected ceiling layout added throughout the floor plan to comply with Architect's concerns. FA-03 Control Relays for Data Room Crac Unit shut down provided inside Data Room 208. FA-03 Additional Horn/Strobe 'AV2/7'added in the large open office area. FA-03 Relocated Horn/Strobe 'AV2/8' to the center of Open Office 207. FA-03 Strobe at Large Conference 206 relocated to opposite side of the light fixtures. FA-04 Single line riser and calculations have been revised accordingly. We have included the original wet stamp set of plans for your reference. I can be reached at (760) 466-2707 should you have any questions. Respectfully, Dante Gomez Dennis Grubb and Associates, LLC Assisting cities Build Safe communities To: City of Carlsbad 1635 Faraday Ave Carlsbad, CA 92008 Date: 2/11/2021 DGA#: C1042 Carlsbad Permit #: FPC202I-0004 Attention: Fire Prevention Department Project Address: 2742 State St PLAN TYPE LI Alarm Sys (new) LI Architectural New: LI Sprinkler TI 0 7-100 Heads LI Underground 0 Lg El Sm LI Special Extinguish Sys LI Spray Booth: # LI Hazardous Material (Non H) LI Special Hazard: LI Other: Z Alarm Sys (TI) LI AS Monitoring LI Architectural: LI HPS LI Sprinkler New LI Sprinkler 13D 0 <1000 > 100 Risers: LI Hood Suppression Sys LI Fire Pump LI Pre-Action System LI AST/UST LI Compressed/Med Gas LI Solar System Li Chem Class: 0<10 0 10-25 0 26-100 Lii> 100 LI Conditional Use Permit LI Site PLAN STATUS APPROVED: The plans have been reviewed for compliance to applicable agency codes and standards. The plans are approved for issuance for applicable permit(s) pending the approval of any other applicable County/City agencies. LI NOT APPROVED: The plans have been reviewed for compliance to applicable agency codes and standards. Corrections are required before the plans can be approved. See the attached correction letter. Comments: Fees: $136 6560 Van Buren Blvd, Ste B, Riverside, CA. 92503 (800) 975-7395 * (951)772-0007 Iflorml Fm7EppmsFs FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS WBG SAN DIEGO TENANT IMPROVEMENT 2742-2752 STATE ST. CARLSBAD, CA 92008 FIRE ALARM SYSTEM TENANT IMPROVEMENT PRODUCT DATA SHEETS SYSTEM SENSOR"' Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L.Series offers -he most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling moun:irg options, System Sensor [-Series can meet virtually any application requirement. The entire [-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually elimina:irg costly and time- consuming ground faults. To further simplify installation, the [-Ser,es utilizes a universal mounting plate so installers can mount -ham to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt cevices t a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING APPROVED LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 AV0S86802 • 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuif Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177.. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. hArm Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868.02 • 12/01/2017 • Page 2 UL Current Draw Data 8-175 Volts 16-33 Volts Candela DC DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hih 42 43 54 DC Input 8-17.5 Volts l5cd 30cd 16-33 Volts 15cd 300d 75cd 95cd uSed 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.lKTemporal High 108 135 179 200 225 255 289 3.1KTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1KNon-Temooral Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86802 • 2/01/2017 • Page 3 2.47 (62.7 mm) 1.37" (34.8 mm) 6.83 di-- (173n 6.92" diam. (175. L-Series Dimensions A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 1-01 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red .PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 4"\ SYSTEM 3825Ohio Avenue • St. Charles, IL 60174 ©2017 System Sensor. Product specifications subject to change wbhnut notice. Visit uystemsensnr.cmll 5EJsoR Phone: 800-SENSOR2 • Fax- 630-377-6495 for current product information, including the latest version of this data sheet. AVD5868-02 • t2jot/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *4\ Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc ri This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeyweIl.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt ii This the listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VA operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division DN-6999:E Monitor Modules NMM.1 00(A), NMM..1 OOP(A), NZM-1 00(A), and NDM.100(A) for FireWarden Series S - - Intelligent Addressable Devices Four different monitor modules are available for Notifier's FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- tact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-IOOP(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTM is a communication protocol that greatly increases the speed of communication between analog intel- ligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. NMM.100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 —99 on FireWarden-100- 2, 01 —50 on FireWarden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used NMM-100(A) (Type H) to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM..1 OOP(A) Mini Monitor Module Built-in type identification automatical y identifies this device as a monitor module to the panel. DN-6999:E • 07133/2015— Page 1 of 4 Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 —99 on FireWarden-100-2, 01 - 50 on FireWarden-50. 1415 0 1 ADDRESS 0 r 1 LOO 14 9 —f6 9 -6 TENS ONES o .-J Ui Q () ilL] [1 The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-IOOP(A) is intended for use in intelli- gent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two- wire initiating device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-IOOP(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. NMM-IOOP(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). NMM-'lOOP(A) SPECIFICATIONS' Nominal operating voltage: 15 to 32 VDC: Average operating current 350 pA I communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage 11 Volts Maximum IDC Current: 450 pA.. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6(15.24cm) minimum. NZM-1 00(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address:, 01 —99 on FireWarden- 100-2, 01 —50 on FireWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It trans- mits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2014— DN-6999:E •07/30/2015 NDM.1 00(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing) Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMBSOO surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. ° UL: S635. ULC:S635. FM Approved. CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100). MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100). Product Line Information NOTE: 'A" suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM IOOP(A) Monitor module miniature NZM-1 00(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. DN-6999:E .07/30/2015 - Page 3 of 4 Notifier® and Fire Warden® are registered trademarks and LiteSpeedTM and FireWatch are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I?INC &MNUFACNC QUALITY SYSTEMS All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4— DN-6999:E • 07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7300-0028:0230 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM1006 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division dn-60383:A2 NC-100R(A) Relay Module for FireWarden Series Panels General The NC-100R(A) Addressable Relay Module provides NOTI- FIERs FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFl). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-1 00-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-1 OOR(A) uses one of the addresses on a SLC loop, It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. NOTIFIER by Honeywell (Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating Current: 230 pA direct poll (CLIP mode), :255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 491C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (11.43 cm) high x 4 (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125' (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (LIR5ms) Coded 30 VDC 0.5 A Inductive (L/R=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2 • 06/17/10 -Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. ULJULC Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-i OOR Intelligent addressable relay module NC-i OORA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. - --- This document is not intended to be used for installation purposes. MERE==I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEBUNC A MNUMC1UNG All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161 FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-60383:A2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY.,7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models NMM-11OOP, NMM-100, and NZM-100 monitor modules; Models NC-IOOR and NC-1 00 control modules; and *NzM..100..6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 0 ,&A9c; /oocf SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time ofsystem acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert NM in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: Supplemental Pages Attached: n/a PROPERTY INFORMATION Name of property: WBG San Diego - Fire Alarm TI Address: 2742-2752 State Street, Carlsbad, CA 92008 Description of property: Retail/Office Name of property representative: Address: Phone: Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: JJJ ENTERPRISES Address: 115 MARKET PL, ESCONDIDO, CA 92029 Phone: 760-747-3050 Fax: 760-747-7561 E-mail: INFO@JJJENT.COM Service organization: SAME AS ABOVE Address: Phone: Fax: E-mail: Testing organization: SAME AS ABOVE Address: Phone: Fax: E-mail: Effective date for test and inspection contract: n/a Monitoring organization: GMS Address: 1127 LOMA AVE, LONG BEACH, CA 90804 Phone: 888-467-1119 Fax: E-mail: Account number: J71035 Phone line 1: Phone line 2: Means of transmission: Cell Entity to which alarms are retransmitted: Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: NEXT TO FACP DESCRIPTION OF SYSTEM OR SERVICE This is a: 0 New system S Modification to existing system Permit number: FPC-2021-0004 NFPA 72 edition: 2019 4.1 Control Unit Manufacturer: NOTIFIER Model number: NFW-100x 4.2 Software and Firmware Firmware revision number: 26 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: N/A Alarm verification set for seconds (p.1 of 3) I. SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120VAC Overcurrent protection: Type: CIRCUIT BREAKER Branch circuit disconnecting means location: HOUSE PANEL Control panel amps: 5 AMPS Amps: 20 Number: HM-37 5.1.2 Secondary Power Type of secondary power: BATTERIES Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 HOURS In alarm mode (minutes): 5 MINUTES 5.2 Control Unit This system does not have power extender panels 0 Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line N/A N/A B Device Power N/A N/A B Initiating Device N/A N/A B Notification Appliance N/A N/A B 1 Other (specify): N/A N/A N/A N/A REMOTE ANNUNCIATORS' Type Location ANN-80 KEYPAD (EXISTING) MAIN ENTRY OF BOTH BUILDING INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations I (EXIST) ADDRESSABLE ALARM DRY CONTACT Smoke Detectors 5 (EXIST) ADDRESSABLE ALARM/SUPV PHOTOELECTRIC Duct Smoke Detectors 8 (NEW) CONV W/ADDR MOD SUPV PHOTOELECTRIC Heat Detectors 1 (EXIST) ADDRESSABLE ALARM HEAT Gas Detectors 0 N/A N/A N/A Waterfiow Switches 1 (EXIST) N/A N/A DRY CONTACT Tamper Switches 2 (EXIST) ADDRESSABLE SUPV DRY CONTACT (p.2 of 3) 'I A SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible 0 N/A Visible 12 (NEW) SYSTEM SENSOR STROBE Combination Audible and Visible 12 (NEW) SYSTEM SENSOR STROBE HORN SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices N/A HVAC Shutdown 8 Fire/Smoke Dampers N/A Door Unlocking N/A Elevator Recall EXISTING Elevator Shunt Trip EXISTING INTERCONNECTED SYSTEMS This system does not have interconnected systems. 0 Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system& ifiçdrJg bee..if st JJJ ENT to all NFPA standards cited herein. name: VINNIE BRUZZI Title: FORMAN Date: Phone: 760-747-3050 12.2 System Operitional Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: SAME AS ABOVE Printed name: Organization: Title: 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative: Jim McKinley Testing contractor representative: Jim McKinley ( ACCEPTANCE TESTING) Property representati AHJ representative: Date: Phone: (p.3 of 3) INTERCONNECTED SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION This form is a supplement to the System Record of Completion. It includes a list of types and locations of systems that are interconnected to the main system. This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Form Completion Date: Number of Supplemental Pages Attached: 1 PROPERTY INFORMATION Name of property: WBG San Diego - Fire Alarm TI Address: 2742-2752 State Street, Carlsbad, CA 92008 INTERCONNECTED SYSTEMS See Main System Record of Completion for additional information, certifications, and approvals. Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 1of 1) Ii.