HomeMy WebLinkAbout2500 CAMPBELL PL; ; FA080030; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA080030 Job Address: 2500 CAMPBELL PL Permit Type: FALARM Parcel No: 2132610500 Lot #: 0 Status: ISSUED Applied 5/12/2008 Approved: 5/15/2008 Reference No.: Issued: 5/15/2008 PC #: Inspector: Project Title: BRESSI RANCH SELF STORAGE 2 FIRE ALARM INSPECTIONS @ $65/EA Applicant: SWIFT COMMUNICATIONS 4365 MEADE AV SAN DIEGO CA 619 640-3959 Owner: V P I BRESSI STORAGE L L C ATTN BRET GOSSETT 8910 UNIVERSITY CENTER LN #630 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 Parsley Consulting 350 West 9d1 Avenue, Suite 206 Escondido, California 92025-5053 Telephone (760) 745-6181 Fax(760) 745-0537 April 25, 2008 Mr. James Weigand City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review of Second Submittal for Bressi Ranch Self Storage Alarms, 2500 Campbell Place, Carlsbad, CA Dear Mr Weigand: We have reviewed the submittal as prepared by Swift Communications. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. Further submittal should not be required. Sincerely, XennXet'h EY CONSULTING ti a41 W. agone1T Office Manager End (1) Working Drawings - 2 sets Product Submittal -2 sets Review Comments - 1 set Note: A copy of this letter has been transmitted via fax to Swift Communications on April 25, 2008 fite:\S:\REVIEWS\Rev2O8 155.003.wpd Bressi Ranch Self Storage Alarms Review Comments. Page 2 Review Comments Bressi Ranch Self Storage Alarms, 2500 Campbell Place, Carlsbad, CA L FAog ocw DF-52130:A • E-350 CMF and CRF Series Addressable Control and Relay Modules (a Flt uearms by Honeywell H I General CMF-300 Control Module: The CMF-300 Addressable Con- trol Module provides Fire'Lite intelligent control panels a circuit for Notification Appliances (horns, strobes, etc.). Addressabil- ity allows the CMF-300 to be activated through panel program- ming, on a select (zone or area of coverage) basis. CRF-300 Relay Module: The CRF-300 Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, door hold- ers, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTm is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The CMF-300 module requires power (for horns, strobes, etc.). Integral LED 'blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). The CMF-300 may be used to switch 24-volt NAC power. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for MS-9600, 01 - 99 on MS-9200UDLS and MS-9050UD. Applications The CMF-300 is used to switch 24 VDC audible/visual power. The CRF-300 may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-159). The CMF-300 is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300 provides two Form-C dry contacts that switch together. CMF-300 Module (see wiring diagram Fig. 5 for CRF-300) Operation Each CMF-300 or CRF-300 uses one of 159 possible module addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The CMF-300 supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. NOTE: Open/short supervision is suspended with the CRF-300. Upon code command from the panel, the CMF-300 will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. . Rotary switches set a unique address for each module. The address may be set beforeor after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for CMF.300 Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll (CLIP mode), 375 pA group poll (LiteSpeed mode) with LED flashing. External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). DF-52130:A.6/11/07—Page 1 of 4 .1 I I L I I I I I I I I I I I I I These plaits have been reviewed for apparent compliance with the current applicable codes and standards In force in the jurisdiction. The owner or contractor may L10 111C /c this review ill suprAlm'"IR , QuI1861'A" in no way relieves the owner (it contractor or th professional engineer or architect for sole responsi for full C(,lll)Pl including the ADFf deficiencies, errors, omissions or negligence in these plaits whether or not noted in this review. Date- Review/ 0 RECOMMEND APPROVAL RECOMMEND APPROVAL. AS NOTED LilTTED - mm - mm m - - _ - - M.M mm _ _ ISOLATED QUADRANT -'is Note CBSOO Module Barrier, which creates isolated quadrant. Page 2 of 4— DF-52130:A • 6/11/07 I I I I I I I I I I I I I I I I I I Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Specifications for CRF.300 Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. RELAY CONTACT RATINGS FOR BOTH CMF-300 AND CRF-300 MODELS Load Application Maximum Current Description Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive Coded 30 VDC 0.5 A (L/R=5ms) Inductive Coded 30 VDC 1.0A (LIR=2m5) Inductive (PF=0.35) Non-Coded 125 VAC 0.5A Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: CS3965 FM Approved CSFM: 7300-0075:185 MEA: 72-01-E PRODUCT LINE INFORMATION CMF-300: Intelligent Addressable Control Module. CRF-300: Intelligent Addressable Relay Module:' SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as CM F-300. CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Wiring Diagrams The following wiring diagrams are provided: CMF-300: Typical notification appliance circuit configuration, NFPA Style V. CMF-300: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. CRF-300: Relay module wiring diagram. Figure 1 CMF-300 Typical notification appliance circuit configuration, NFPA Style Y. Connect modules to Listed Communication Line 32 VDC max. compatible Fire'Lite control Refer to panel documentation for panels only TO Nest Devic e type of cob le required. FROM Panel or Previous All wiring shown is CONTROL Device supervised and power MODULE 24 VDC Circuit limited. 471< EOL DO NOT LOOP wire Resistor on terminals 3 & 4. / Module polarities are ELR-47K B 1 Break wire to provide shown in alarm. — — EM 7 29 supervision of connections. 60 3 24 VDC 0— ADDRESS 1 POWER SUPPLY _-1 (+) (+ ) Power Supply: UL listed Isolated, regulated, EOL Relay TO NEXT control module or EOL Relay. power-limited per NFPA 70. shown ONE RELAY REQUIRED for each circuit. Listed for fire protection energized Some control panels have the RELAYBUILTIN 24 VDC coil and do not require external wiring. with battery backup. 6724w1r1.wmt EOLR-1 Refer to the manual. CMF-300 Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to Listed Communication Line 32 VDC max. TO Nest Refer to panel documentation for compatible Fire•Lite control panels only. Device cablerequired. FROM Pane! or Previous \ All wiring shown is CONTROL Device supervised and power EOL Resistor is internal at MODULE 24 VDC Circuit limited, terminals 8 & 9 — DO NOT LOOP wire on terminals 3 & 4. . Module polarities are Break wire to provide shown in alarm. — supervision of connections. 24VDC ADDRESS POWER SUPPLY Power Supply: __- Isolated, regulated, L listed EOL Relay TO NEXT control module or EOL Relay. power-limited per NFPA 70. shown ONE RELAY REQUIRED energized Some control panels have for each circuit. the RELAY BUILT IN Listed for fire protection with battery backup. 24 VDC coil and do not require external wiring. 6724wir2.wml EOLR-1 Refer to the manual. CRF-300 Relay module wiring diagram. Connect modules to Listed - (' TO Next - FROM Panel compatible Fire•Lite control Device (+) or Previous only. panels 4------- ------, Device R LAY . Module does NOT --------- '. Corn munication Line supervise controlled MODULE 32 VDC maximum. Refer to documentation circuits. panel for type of cable required. RELAY COMMON 2 9— 0 H NORMALLY CLOSED 2 NORMALLY OPEN 2 s$-4 1 2 RELAY COMMON I 6—, 3 5 -*L.i F4 Ej NORMALLY CLOSED 1 NORMALLY OPEN 1 I LOOP ADDRESS e724wmt I I DF-52130:A • 6/11/07 - Page 3 of 4 I Li September 20, 2004 DF-52220• D-250 (9 Fire-LIMALarms www.firelite.com GENERAL The CHG-75 battery charger is designed to charge lead- acid batteries that provide emergency standby power for a Fire Alarm Control Panel (FACP) and related equipment. Two 12-volt batteries are used in series to supply a nomi- nal 24 VDC. The battery charger is compatible with any FACP that uses lead-acid batteries with a rating of 25 AH (amp-hours) to 75 AH. The FACP must have a feature that allows the disabling of the control panel battery charger. FEATURES 120 VAC or 220/240 VAC operation. Rated for batteries 25 to 75 AH. Charger can connect to the Signaling Line Circuit (SLC) of a Fire-Lite intelligent control panel (e.g., MS-9200, MS- 9600, and MS-9200UD) for trouble monitoring. Mounts in a BB-26, BB-55F, MS-9600 or MS-9200 en- closure. Screw terminal connections for battery, battery backup to other equipment and SLC loop. 6.25 A fuse (Fl) for AC overload protection. 15.0 A replaceable fuse (F2) provides battery with cur- rent-limiting, short circuit, and overload protection. 15.0 A replaceable fuse (173) provides battery with cur- rent-limiting and overload protection for output to con- nected equipment. Form-C trouble relay rated for 2.0 A @ 30 VDC (resis- tive). Ground fault detection circuit (can be disabled). Battery, charger, and AC voltage supervision. AC loss reporting delay option for 8- or 16-hour delay. Connectors for trouble input and output - direct CHG- 75 troubles to FACP and allow daisy-chaining of exter- nal troubles through the charger without affecting charger operation. Master trouble input allows monitoring of another de- vice or zone. Connectors for optional AM-1 ammeter and VM-I volt- meter. Diagnostic LEDs for monitoring: Primary AC On, Charger Trouble, Ground Fault, Charging, SLC Communication, Low Battery. CONSTRUCTION AND OPERATION The CHG-75 consists of a PC board and mounting chas- sis. Aside from mounting options (see Installation), the only options involved in ordering the CHG-75 are the choice of an AM-1 Ammeter or a VM-1 Voltmeter. CHG-75 Battery Charger Section: Power Supplies/Accessories California (ii MEA SMarshal tate Are 297-01-E 7315-0075:201 LISTED S1287 Charging current is provided automatically when the bat- tery voltage falls below the charger's output voltage. While charging the batteries, the CHGING (charging) LED will turn on. When batteries are fully charged, the charger maintains a float charge of 27.6 VDC. The SLC LED and AC LED are the only other LEDs that should be on during normal operation if SLC communication is programmed at the FACP and the SLC enable switch is On. APPLICATIONS Use the CHG-75 with Fire-Lite MS-9200 or MS-9600 when batteries required for standby are rated equal to or greater than 25 AH. 4Y1ON! When installing the batteries, make certain that proper polarity is observed between the power leads and the battery terminal posts. I Ll I I I I I I I II [I I I Fire-Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep IS09001 our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, ENGINEERING & MNDFAE1UIING QUALITY SYSTEMS Made in the U.S.A. Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. DF-52220 • 09/20/04 - Page 1 01 El I I CHG-75 SPECIFICATIONS Primary AC power in (TBI): 120 VAC, 60 Hz, 2.0 A; or 220/ 240 VAC, 50 Hz, 1.0 A. Wire size: minimum 14 AWG (2.0 mm2) with 600-volt insulation. Form-C relay (TB4): 2.0 A at 30 VDC (resistive). Float charge voltage: 27.6 VDC. Maximum charging current: 4.5 A (peak). Battery sizes: 25 AH to 75 AH. INSTALLATION The CHG-75 has a variety of mounting options. It can be mounted in either the FACP (MS-9200, MS-9600), or re- motely in the BB-26 or BB-55F battery backbox. Install the CHG-75 within 20 feet (6.096 m) of the main FACP. When mounting in a FACP: The CHG-75 can be mounted in the bottom of the MS-9600 backbox, using the self-tap- ping screws included with the charger. In a similar fash- ion, the supplied nuts can be used to mount the charger to pem studs located in the bottom of the MS-9200 backbox. A separate battery box must be used to house the batter- ies when employing these configurations. When mounting remotely in the BB-55F: The CHG-75 mounts to the right of the AM-1NM-1 mounting holes posi- tioned at the top of the cabinet. Use the supplied self-tap- ping screws to secure the charger to the backbox. When mounting remotely in the BB-26: The CHG-75 mounts just below the AM-1/VM-1 mounting holes posi- tioned at the top center of the cabinet. Use the supplied nuts to mount the charger to pem studs located in the backbox. Meter configurations/installation: Order the AM-1 (amme- ter) and/or the VM-1 (voltmeter) when either option is re- quired and the charger is mounted in the BB-26 or BB-55F battery backbox. PANEL BATTERY CHG-75 BOARD CONNECTION it AIaI%II VM-1 voltmeter can be installed on the CHG-75 to provide a visual indication of the battery/charger voltage. When the battery is disconnected, the voltmeter mea- sures charger voltage only. The VM-1 can mount into a mounting slot on the front of the BB-26 or BB-55F battery box. AM-1 ammeter can be installed on the CHG-75 to provide a visual indication of the charger current. The AM-1 can mount into a mounting slot on the front of the BB-26 or BB-55F battery box. AGENCY LISTINGS AND APPROVALS The CHG-75 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 1481 Power Supplies for Fire Alarm Systems. See the first page of this data sheet for listing agencies and file numbers. These listings and approvals apply to the CHG-75. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. PRODUCT LINE INFORMATION CHG-75: battery charger circuit board and mounting chas- sis. Includes mounting hardware and installation instruc- tions. BAT-I2260: 26 AH, 12-volt, sealed lead-acid battery. BB-26: battery backbox - holds up to two BAT-12260 26 AH batteries. Box dimensions: 15.6" (39.62 cm) wide x 15.5" (39.37 cm) high x 5.125(13.02cm) deep. Door dimensions: same dimensions as backbox. BB-55F: battery backbox - holds up to two BAT-12550 55 AH batteries. Box dimensions: 24.0" (61.0 cm) wide x 14.0" (35.6 cm) high x 7.75" (19.7 cm) deep. Door dimensions: 24.125" (61.3 cm) wide x 14.25" (36.2 cm) high x (door adds 0.063" [approx. 0.16 cm] to depth). AM-I: ammeter, 0-10 amps, for CHG-75 mounted in 88-26 or BB-55F. VM-I: voltmeter, 0-50 volts, for CHG-75 mounted in BB-26 I I I I I I [1 I I I I I I I I I I I Page 2 of 2— DF-52220 • 09120/04 1 6933c0vjpg Agency Listings and Approvals I . I I I I I I I I I I I I I I I I I I DF-52397:A • D-500 BAT Series Batteries Fire ietarms Sealed Lead-Acid by Honeywell General BAT Series Batteries feature a new part-numbering/listing sys- tem - providing an improved method of delivery for Fire-Lite- approved sealed lead-acid batteries for all your fire alarm sys- tem needs. Multiple brands of batteries are now offered under generic part numbers, reducing backorder situations and permit- ting us to deliver these products in a more timely fashion. Fire-Lite has approved the multiple brands listed below as pos- sible product shipped for a given part number. Please note that any incoming orders for "PS Series" batteries will be converted to the equivalent BAT Series part numbers. Features Provide secondary power for control panels. Sealed and maintenance-free. Overcharge protected. Easy handling with leakproof construction. Ruggedly constructed, high-impact case (ABS, polystyrene, Long service life. or polypropylene, depending on models). for latest listing status. The listings and approvals below apply to BAT Series Batteries. approval agencies, or listing may be in process. Consult factory UL Recognized Components: files MH19884 (B & B Bat- In some cases, certain modules may not be listed by certain tery), MH20727 (UPQ previously Jolt), MH20845 (Power- Compact design. Sonic). Part Number Reference 6933key1.tbl PREVIOUS CURRENT BATTERY ALTERNATES APPROVED: Part Number Part Number DESCRIPTION manufacturers and P/Ns shipped under BAT P/Ns PS-612 Discontinued N/A N/A PS-695 Discontinued N/A. N/A PS-1242 BAT-I250 12 V, 5 AH, sealed. BP5-12 (B&B Battery); PS-1250 (Power-Sonic); SAl 250 (Jolt) to be replaced with UB1250 (UPG). PS-1250 BAT-I250 12 V, 5 AH, sealed. BP5-12 (B&B Battery); PS-1250 (Power-Sonic); SA1250 (Jolt) to be replaced with UB1250 (UPG). PS-1270 BAT-I270 12 V, 7 AH, sealed. BP7-12 (B&B Battery); P8-1270 (Power-Sonic); SAl 272 (Jolt) to be replaced with UB1270 (UPG). PS-12120 BAT-12120 12 V, 12 AH, sealed. BP12-12 (B&B Battery); PS-12120 (Power-Sonic); SA12120 (Jolt) to be replaced with UB12120 (UPG). PS-12170 BAT-12180 12 V, 18 AH, sealed. PS-12180 (Power-Sonic); SA12180 (Jolt) to be replaced with UB12180 (UPG). PS-12180 BAT-I2I80 12 V, 18 AH, sealed. PS-12180 (Power-Sonic); 5A12180 (Jolt) to be replaced with UB12180 (UPG). PS-12250 BAT-I2260 12 V, 26 AH, sealed. BP26-12 (B&B Battery); PS-12260 (Power-Sonic); SA12260 (Jolt) to be replaced with UB12260 (UPG). PS-12550 BAT-12550 12 V, 55 AH, sealed. PS-12550 (Power-Sonic); XSA1 2550 (Jolt) to be replaced with UB12550 (UPG). PS-12600 BAT-12550 12 V, 55 AH, sealed. PS-12550 (Power-Sonic); X5A12550 (Jolt) to be replaced with UB12550 (UPG). P8-12750 Discontinued N/A N/A PS-121000 BAT-121000 12 V, 100 AH, gell cell. PS-121000 (Power-Sonic); XSAI21000A (Jolt) to be replaced with UB121000 (UPG). DF-52397:A• 12/29/06 - Page 1 of 10 0 it 80% 70% 60% C) a 50% Co 0 40% 0% 100% 80% ca of .' 60% C) Cs cc 40% 20% 0% .'.uiI.I Ambient w wal i I I h9h, I 01101011115,10M tage at left: PS-1210000 Discharge Characteristics I I I I I I I I I I I I I I I I I I I POWER-SONIC MODEL Nominal Voltage V Nominal Capacity @ 20 hr. rate A.H. Discharge Current 20 hr. rate milk DIMENSIONS Wdth Depth Height over terminal Weight __7__F in. . - in. - mm. - in. - m. - in. - mm. - lbs. - kg. PS-1250 12 5.0 250 3.54 90 2.76 70 4.02 102 4.21 107 4.1 1.9 PS-1270 12 7.0 325 5.94 151 2.56 65 3.70 94 3.86 98 5.7 2.6 PS-12120 12 12 600 5.94 151 3.86 98 3.70 94 3.86 98 8.8 4.0 PS-12180 12 18 875 7.13 181 2.99 76 6.57 167 6.57 167 12.8 5.8 PS-12250 12 25 1300 6.89 175 6.54 166 4.92 125 492 125 18.7 8.5 PS-12550 12 55 3000 10.25 260 6.60 168 8.20 208 9.45 240 39.7 18.0 PS-121000 12 100 5000 12.00 305 6.60 168 8.20 208 1 9.45 240 65.7 29.8 120% Effect of Temperature on Capacity MENEM MOP INS I. PIP a FRAN Mw M 0 0 0 0 MMMMMEEM -20° -10° 0° 10° 20° 30° 40° 50° 60° Temperature (Degrees C.) at left: PS-121000 Shelf-Life and Storage 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) 14.0 V 13.0 V 12.0 V is 11.0 V Cs 10.0 V 9.0 V 8.0 V 1.2 2.4 6 12 24 36481 2 4 6 810 20 40 MINUTES HOURS Discharge Time Page 2 of 10- DF-52397:A • 12/29/06 Characteristic Discharge Curves 6.5 13 2 6.0 12 5) 1 ii 5.0 10 Cs 4.5 9 4.0 8 1 2 3 5 10 2030 60 2 3 5 10 20 30 minutes hours Discharge Time @ 20°C (68°F) 100% 90% Charging is NOT necessary unless 100% of capacity is required. 5 (41 F) Charging before use is necessary to help recover full capacity. Charge may fail to restore full capacity. 40°C 30°C 20°C (104°F) (86°F) (68°F) 00 NOT let batteries reach this state. I I I I I I I I I I I I I I I I I I I This cabinet consists of a backbox with an integral, lockable door that is hinged on the bottom to swing down for access. It is designed to be mounted a minimum of 6 inches (15.24 cm) below the fire alarm control panel (FACP). When both cabinets are surface mounted, the knockout in the bottom-right corner of the FACP will line up directly above the knockout in the top- right corner of this enclosure. This enclosure should be mounted in a clean, dry, vibration-free area, using the six holes provided. Note: The enclosure has 0.875 in. (2.2225 cm) knockouts which accept standard 0.75 in. (1.905 cm) conduit. 2.80 in. (71.12 mm) 7.73 (196.34 2.66 in. (67.564 mm) 24.125 in. (612.775 mm) Left Side Door 3.875 in. 7.730 in. I (98.425 mm) 16.00 in. (406.4 mm) flTh6.342mfl r03.2 m F 4.00 in. IFfihIfi (101.6 mm) WHJW llll L . .. ... 14.06 in. (357.124 mm) 15.00 in. I (381 mm) E , 6L4 7.250 1.25 in 23.750 in. (603.25 mm) (184.15 mm) (31.75 mm) Front (without door) Battery/Peripherals Enclosure PN 50295:B 07/24/2001 FACP 6 inch minimum (15.24 cm) Conduit : I 0 I Battery/Peripherals Enclosure 2.125 in. (53.975 mm) 10.00 in. (254 mm) 14.75 in (374.65 m I (jJ FireifferALarms A PITTWAY COMPANY B BG-12LX Addressable Pull Station Doc-jment 51094 Revision A2 ECN 00-032 01/14/2000 Description The BG-12LX Addressable pull station is a non-coded, dual-action manual pull station with a key-lock reset fea- ture. It provides Fire-Lite intelligent control panels with one addressable alarm initiating input. The addressable module is housed inside the pull station. The BG-12LX is compatible with all Fire-Lite intelligent panels. The BG-12LX meets the ADA requirement for a 5-lb. maxi- mum pull force to activate the pull station. Operating instructions are molded into the pull station handle along with Braille text. Molded Terminal numbers are also present. Installation The BG-12LX Addressable pull station can be surface mounted to an SB-10 surface backbox or semi-flush mounted on a standard single-gang, double-gang or 4" (10.16 cm) square electrical box. The optional BG-TR trim ring can be used if the BG-12LX is to be semi-flush mounted. Ratings Normal Operating Voltage: 24 VDC. Average Operating Current (LED Flash): 300 pA. Temperature Range: 320 F - 1200 F (00 C - 490 Q. Relative Humidity Range: 10% -93% non-condensing. Setting the BG-12LX Address The BG-12LX Addressable pull station is factory preset with address '00.' Set the address for the pull station by turning the rotary address switches on the addressable mod- ule mounted inside the pull station. Only one device per address is allowed. Multiple modules may not be set to the same address on the Signaling Line Circuit. Once the address is set, record it in the space provided on the prod- uct ID label located inside the pull station. ROTARY ADDRESS SWITCHES LED OPERATION I I I LED 1=1 Irrrr Normal: Flash RED Alarm: 0 Steady RED Note: LED is visible l2 3 EEs1uE 0 handle. 81 law a s 6 ONES IrII . WMUU PRODUCT IDENTIFICATION LABEL - bn If, during mounting of the pull station, the door be- comes detached, complete the following steps to reattach the door to the backplate. The door cannot be connected to the pull station if the unit is mounted to the backbox. Position the door and backplate side by side in the full open position. (i.e. 180-degrees with respect to each other.) With the backplate position fixed, move the door be- hind the backplate, as shown in the illustration, part A. Align the hinge posts and holes by bringing the door up to meet the backplate, paying particular attention to the 'keying' that occurs when the door's post hole is aligned to the backplate's hinge post. Refer to the illustration, part B. With the two pieces aligned and 'keyed' together, slide the holes down onto the posts. Refer to the illustra- tion, part C. Holding the backplate, close the door and backplate slightly to lock the door and backplate together. I I I I I I I r I L I I] I ii Haui HIAM.Uucli L In _0 A DOOR KEYS INTO ACKPLATE AT THIS POINT el/i M.%- - jr From FACP SLC -- I I J • To Next Addressable Device + Wiring If flush mounting, proceed to step 4. Mount the backbox before wiring it to the pull station. Before surface mounting the pull station, pull all wiring through the backbox and optional trim ring. Remove the appropriate amount of wire insulation. The pull station back plate is molded with a strip gauge to measure the amount of insulation to be removed. Connect the wiring from the addressable fire alarm control panel's Signaling Line Circuit (SLC) to Terminals l(-) and 2(+) on the BG-12LX addressable pull sta- tion. SLC polarity is critical for this connection. Connect the wiring going to the next device on the SLC to Terminals 1 and 2, again being certain to observe polarity. Open the pull station door; align the mounting holes of the pull station backplate to the backbox and screw into place. Tighten top and bottom screws. Set the address as described in 'Setting the BG-12LX Address' and write the address in the space provided on the label. Insure that the alarm switch is in the normal position. Close and lock the pull station door. I I I I I I I I I I I I Operation Push-in and pull-down the handle where indicated to activate the station. The BG-12LX manual fire alarm pull station includes one SPST (Single Pole, Single Throw) NIO (normally-open) switch and the addressable mod- ule located inside the station. Pushing-in and pulling-down the dual action handle causes the N/O alarm switch to close. The word 'ACTIVATED' is displayed on the top of the handle when the pull station handle is Pushed-in and pulled-down. The activated handle can not be reset without employing the key-lock reset. To reset the BG-12LX pull station: 1) Insert the key and turn counterclockwise, 2) Open the door until the handle moves back into the 'NORMAL' position, 3) Close the door and lock it. Closing the door automatically resets the BG-12LX to the 'NORMAL' position. I Note IVote - Opening the pull station door will not activate or deactivate the alarm switch. NI IlBU 1wGJJuq DOOR ATTACHMENT With the door and backplate aligned and keyed' together, slide the holes down onto the posts. WI - ri:1 j: POST ACTIVATED BG-12LX PULL STATION CAUTION! Install the Fire-Lite BG-12LX manual pull station in accordance with these instructions, applicable NFPA standards, national and local Fire and Electrical codes and the requirements of the AHJ (Authority Having Jurisdiction). Regular testing of the devices should be con- ducted in accordance with the appropriate NFPA standards. Failure to follow these directions may result in failure of the device to report an alarm condition. Fire-Lite is not responsible for devices that have been improperly installed, tested or maintained. For ADA compliance, if the clear floor space only allows forward approach to an object, the maximum forward reach height allowed is 48 in. (1,220 mm). If the clear floor space allows parallel approach by a person in a wheelchair, the maximum side reach height allowed is 54 in. (1,370 mm). Document 51094 Revision A2 ECN 00-032 01/14/2000 Closing the door slightly locks the door and backplate together. From- 841ee48o2 Pe 212 Oe: 3/3112008 1:4A-54 PM Appilcent ID No; 2?O7-001 Sorvlco Cnw No I Expka; 31-NtA4OO9 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY ti*i m Affirm 8eMoe Company MCWled below is inoksdd by lJndrwltIr liburatode Inc. ((IL) fn lb Pict WDOWIN as ellgfbls 40 two the UL UstinQ Mark In connection with CertIficated Aiim, 8ysIem. Tbe only avidsnos otoompeJce With ui.ffl raquNina n t a i s f t l e u s n c a o f a ULOarmato for the Akin System and the Cartihoia Ia current tider UL . C . v t l n c a t e V e r i t a t I o n G e r i n c e . ALISO VIEJO, CA ADVANCED PRO1ECR0N iNDUStRIES INC, 06ANArIONAL MONrIORING CENTER $Uflt 260 5OO ALISO VIEJO PKT ALSO YIJO CA 92656 ADVANCED FRONCTION INDUSTRIES INC, D$ANAIIONAL PIIONITORIPIG CENTR Surre ,o 26800 AU!O VIEJOPKY ALISO VIEJO CA 9=6 The Arin 64i Cumpeivy Is Listed bi the t0I1owh CerUftcate Setvtas adapdW t5. Y9LPtOk CN jisena Cpj1 90120-1 LJJFX tSianal *M Pbs Absin Equipteset and Sovvlessj (Pretective 5affn9 Seivios.) Csntrei Station These plaits have been reviewed br :ppaltIu coiepliaiice with the cutrent applicable codes and standards in force in the jurisdiction. The owner or contractor 111M utiliie this review in support of all application f0l a permit with the express understanding that this res leo it no way relieves the owner or corillacim or their protissional engineer or architect for sole rcspoioihihi for bull compliance with said codes and standards. - including the building code or for any responsihilty for deticiencies errors. omissions or tteghtgence in these plaits whether or not noted in this review. Date: 4/77O Reviewer: 0 RECOMMEND APPROVAL RECOMMENI) APPROVAl. AS NOTED mmis cR11RCATE EXP$RKON F 'LOOK FOR THE UL ALARM SYSTEM CTI CATE ewci8(IL ;malm This tec 'me teceved byOFI FAXmaker fox sewr. For mote tnfotTnsflcn, vt hnpMdvWw.gticm CMF and CRF Series Addressable Control and Relay Modules General CMF-300 Control Module: The CMF-300 Addressable Con- trol Module provides Fire'Lite intelligent control panels a circuit for Notification Appliances (horns, strobes, etc.). Addressabil- ity allows the CMF-300 to be activated through panel program- ming, on a select (zone or area of coverage) basis. CRF-300 Relay Module: The CRF-300 Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, door hold- ers, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTm is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The CMF-300 module requires power (for horns, strobes, etc.). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). The CMF-300 may be used to switch 24-volt NAC power. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for MS-9600, 01 - 99 on MS-9200UDLS and MS-9050UD. Applications The CMF-300 is used to switch 24 VDC audible/visual power. The CRF-300 may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01 -159). The CMF-300 is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300 provides two Form-C dry contacts that switch together. DF-52130:A • E-350 8 Fire UTGAL&S by Honeywell CMF-300 Module (see wiring diagram Fig. 5 for CRF-300) Operation Each CMF-300 or CRF-300 uses one of 159 possible module addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The CMF-300 supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. NOTE: Open/short supervision is suspended with the CRF-300. Upon code command from the panel, the CMF-300 will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for CMF-300 Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll (CLIP mode), 375 pA group poll (LiteSpeed mode) with LED flashing. External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). DF-52130:A.6/11/07—Page 1 of 4 I ISOLATED QUADRANT ms Note CB500 Module Barrier, which creates isolated quadrant. Page 2 of 4— DF-52130:A • 6/11/07 RELAY CONTACT RATINGS FOR BOTH CMF-300 AND CRF-300 MODELS Load Application Maximum Current Description Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (UR=5m5) Coded 30 VDC 0.5 A Inductive Coded 30 VDC 1.0 A (L/R=2m5) Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: CS3965 FM Approved CSFM: 7300-0075:185 MEA:72-01-E PRODUCT LINE INFORMATION CMF-300: Intelligent Addressable Control Module. CRF-300: Intelligent Addressable Relay Module. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as CMF-300. CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING I , I I I I I I I I I I I I I I I I I I Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Specifications for CRF-300 Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. I Wiring Diagrams The following wiring diagrams are provided: 1. CMF-300: Typical notification appliance circuit configuration, NFPA Style V. I 2. CMF-300: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. 3. CRF-300: Relay module wiring diagram. Figure 1 CMF-300 Typical notification appliance circuit configuration, NFPA Style Y. Connect modules to Listed Communication Line 32 VDC max. Refer required. FROM Panel compatible Fire'Lite control Refer to pane! documentation for panels only. Device or Previous supervised and power TO Next CONTROL . All wiring shown is Device MODULE 24 VDC Circuit DONOTLOOPwire limited. 47K EOL on terminals 3 & 4. Resistor Break wire to provide Module polarities are ELR.47K supervision of connections. shown in alarm. - - P2AESS 24VDC POWER SUPPLY cOe Power Supply: (+) (+) Isolated, regulated, UL listed power-limited EOL Relay • TO NEXT control module or EOL Relay. per NFPA 70. shown ONE RELAY REQUIRED for each circuit. Listed for fire protection energized Some control panels have the RELAY BUILT IN with battery backup. 24 VDC coil and do not require external wiring. e724wirl.wmf EOLR-1 Refer to the manual. CMF-300 Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to Listed Communication Line 32 VDC max. \cuble required. FROM Panel compatible Fire'Lite control Refer to panel documentation for panels only. Device TO Next CONTROL Device or Previous All wiring shown is EOL Resistor MODULE 24 VDC Circuit supervised and power is internal at limited, terminals 8 & g DO NOTLOOPwire on terminals 3 & 4. Break wire to provide Module polarities are 8Q 1 supervision of connections. - - shown in alarm. 24 VDC POWER SUPPLY Power Supply: (+) isolated, regulated, UL listed power-limited EOL Relay • TO NEXT control module or EOL Relay. per NFPA 70. shown ONE RELAY REQUIRED for each circuit. Listed for fire protection energized . Some control panels have the. RELAY BUILT IN with battery backup. 24 VDC coil and do not require external wring. 6724wii2.wof EOLR-1 Refer to the manual. CRF-300 Relay module wiring diagram. Connect modules to Listed - 1" - TO Next FROM Pane! compatible Fire'Lite control Device " , (+) or Previous panels only. +----- __c___ Device Module does NOT - Communication Line . 32 VDC maximum. supervise controlled (37 MODULE Refer to panel documentation circuits. RELAYCOMMON2 9-9 0 fore of cable required NORMALLY CLOSED 2 8 -*4 i NORMALLY OPEN 2 7lI1 2 RELAY COMMON 1 e— 3 NORMALLY CLOSED 1 5 4 NORMALLY OPEN 1 LOOP ADDREIS [1 I DF-52130:A • 6/11/07 - Page 3 of 4 I September 20, 2004 DF-52220 • D-250 (a Flre-LIWALarms www.firelite.com GENERAL The CHG-75 battery charger is designed to charge lead- acid batteries that provide emergency standby power for a Fire Alarm Control Panel (FACP) and related equipment. Two 12-volt batteries are used in series to supply a nomi- nal 24 VDC. The battery charger is compatible with any FACP that uses lead-acid batteries with a rating of 25 AH (amp-hours) to 75 AH. The FACP must have a feature that allows the disabling of the control panel battery charger. FEATURES 120 VAC or 220/240 VAC operation. Rated for batteries 25 to 75 AH. Charger can connect to the Signaling Line Circuit (SLC) of a Fire-Lite intelligent control panel (e.g., MS-9200, MS- 9600, and MS-9200UD) for trouble monitoring. Mounts in a BB-26, BB-55F, MS-9600 or MS-9200 en- closure. Screw terminal connections for battery, battery backup to other equipment and SLC loop. 6.25 A fuse (Fl) for AC overload protection. 15.0 A replaceable fuse (F2) provides battery with cur- rent-limiting, short circuit, and overload protection. 15.0 A replaceable fuse (F3) provides battery with cur- rent-limiting and overload protection for output to con- nected equipment. Form-C trouble relay rated for 2.0 A @ 30 VDC (resis- tive). Ground fault detection circuit (can be disabled). Battery, charger, and AC voltage supervision. AC loss reporting delay option for 8- or 16-hour delay. Connectors for trouble input and output - direct CHG- 75 troubles to FACP and allow daisy-chaining of exter- nal troubles through the charger without affecting charger operation. Master trouble input allows monitoring of another de- vice or zone. Connectors for optional AM-1 ammeter and VM-I volt- meter. Diagnostic LEDs for monitoring: Primary AC On, Charger Trouble, Ground Fault, Charging, SLC Communication, Low Battery. CONSTRUCTION AND OPERATION The CHG-75 consists of a PC board and mounting chas- sis. Aside from mounting options (see Installation), the only options involved in ordering the CHG-75 are the choice of an AM-1 Ammeter or a VM-i Voltmeter. CHG-75 Battery Charger Section: Power Supplies/Accessories California MEA State Fire Marshal 297-01-E 7315-0075:201 LISTED Si287 CHG-75 -. C) Charging current is provided automatically when the bat- tery voltage falls below the charger's output voltage. While charging the batteries, the CHGING (charging) LED will turn on. When batteries are fully charged, the charger maintains a float charge of 27.6 VDC. The SLC LED and AC LED are the only other LEDs that should be on during normal operation if SLC communication is programmed at the FACP and the SLC enable switch is On. APPLICATIONS Use the CHG-75 with Fire-Lite MS-9200 or MS-9600 when batteries required for standby are rated equal to or greater than 25 AH. AiJYiOiJ! When installing the batteries, make certain that proper polarity is observed between the power leads and the battery terminal posts. Fire-Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific IS09001 applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, ENCINEEIINC & MANUME1UI116 Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. 1 QUALITY SYSTEMS Made in the li.S.A CHG-75 SPECIFICATIONS Primary AC power in (TB1): 120 VAC, 60 Hz, 2.0 A; or 220/ 240 VAC, 50 Hz, 1.0 A. Wire size: minimum 14 AWG (2.0 mm2) with 600-volt insulation. Form-C relay (TB4): 2.0 A at 30 VDC (resistive). Float charge voltage: 27.6 VDC. Maximum charging current: 4.5 A (peak). Battery sizes: 25 AH to 75 AH. INSTALLATION The CHG-75 has a variety of mounting options. It can be mounted in either the FACP (MS-9200, MS-9600), or re- motely in the BB-26 or BB-55F battery backbox. Install the CHG-75 within 20 feet (6.096 m) of the main FACP. When mounting in a FACP: The CHG-75 can be mounted in the bottom of the MS-9600 backbox, using the self-tap- ping screws included with the charger. In a similar fash- ion, the supplied nuts can be used to mount the charger to pem studs located in the bottom of the MS-9200 backbox. A separate battery box must be used to house the batter- ies when employing these configurations. When mounting remotely in the BB-55F: The CHG-75' mounts to the right of the AM-1NM-1 mounting holes posi- tioned at the top of the cabinet. Use the supplied self-tap- ping screws to secure the charger to the backbox. When mounting remotely in the BB-26: The CHG-75 mounts just below the AM-1/VM-1 mounting holes posi- tioned at the top center of the cabinet. Use the supplied nuts to mount the charger to pem studs located in the backbox. Meter configurations/installation: Order the AM-1 (amme- ter) and/or the VM-1 (voltmeter) when either option is re- quired and the charger is mounted in the BB-26 or BB-55F battery backbox. PANEL BATTERY CHG-75 BOARD CONNECTION AI AIIU&U + VM-I voltmeter can be installed on the CHG-75 to provide a visual indication of the battery/charger voltage. When the battery is disconnected, the voltmeter mea- sures charger voltage only. The VM-1 can mount into a mounting slot on the front of the BB-26 or BB-55F battery box. AM-1 ammeter can be installed on the CHG-75 to provide a visual indication of the charger current. The AM-1 can mount into a mounting slot on the front of the BB-26 or BB-55F battery box. AGENCY LISTINGS AND APPROVALS The CHG-75 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 1481 Power Supplies for Fire Alarm Systems. See the first page of this data sheet for listing agencies and file numbers. These listings and approvals apply to the CHG-75. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. PRODUCT LINE INFORMATION 'CHG-75: battery charger circuit board and mounting chas- sis. Includes mounting hardware and installation instruc- tions. BAT-12260: 26 AH, 12-volt, sealed lead-acid battery. BB-26: battery backbox - holds up to two BAT-12260 26 AH batteries. Box dimensions: 15.6" (39.62 cm) wide x 15.5" (39.37 cm) high x 5.125" (13.02 cm) deep. Door dimensions: same dimensions as backbox. BB-55F: battery backbox - holds up to two BAT-12550 55 AH batteries. Box dimensions: 24.0" (61.0 cm) wide x 14.0" (35.6 cm) high x 7.75" (19.7 cm) deep. Door dimensions: 24.125" (61.3 cm) wide x 14.25" (36.2 cm) high x (door adds 0.063" [approx. 0.16 cm] to depth). AM-I: ammeter, 0-10 amps, for CHG-75 mounted in BB-26 or BB-55F. VM-1: voltmeter, 0-50 volts, for CHG-75 mounted in BB-26 I I I I I I El I I I I I I Page 2 of 2— OF-52220 • 09/20/04 1 I I I I I I I I I I I I I I DF-52397:A • D-500 BAT Series Batteries Sealed Lead-Acid (a Fire Lrre®Atarms by [s1IIYA!i!Li Power Supplies/A fleneral BAT Series Batteries feature a new part-numbering/listing sys- tem - providing an improved method of delivery for Fire-Lite- approved sealed lead-acid batteries for all your fire alarm sys- tem needs. Multiple brands of batteries are now offered under - generic part numbers, reducing backorder situations and permit- ting us to deliver these products in a more timely fashion. 49 W Fire-Lite has approved the multiple brands listed below as pos- sible product shipped for a given part number. Please note that any incoming orders for "PS Series' batteries will be converted to the equivalent BAT Series part numbers. 6933cov.g Features Sealed and maintenance-free. Provide secondary power for control panels. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batteries. Overcharge protected. In some cases, certain modules may not be listed by certain Easy handling with leakproof construction. approval agencies, or listing may be in process. Consult factory Ruggedly constructed, high-impact case (ABS, polystyrene, for latest listing status. or polypropylene, depending on models). • UL Recognized Components: files MH19884 (B & B Bat- Long service life. tery), MH20727 (UPG, previously Jolt), MH20845 (Power- Compact design. Sonic). Part Number Reference 6933kvl thi PREVIOUS CURRENT BATTERY ALTERNATES APPROVED: Part Number Part Number DESCRIPTION manufacturers and P/Ns shipped under BAT P/Ns PS-612 Discontinued N/A N/A PS-695 Discontinued N/A. N/A PS-1242 BAT-1 250 12 V, 5 AH, sealed. BP5-12 (B&B Battery); P5-1250 (Power-Sonic); 5A1250 (Jolt) to be replaced with UB1250 (UPG). P5-1250 BAT-1 250 12 V, 5 AH, sealed. BP5-12 (B&B Battery); PS-1250 (Power-Sonic); SA1250 (Jolt) to be replaced with UB1250 (UPG). PS-1270 BAT-I270 12 V, 7 AH, sealed. BP7-12 (B&B Battery); PS-1270 (Power-Sonic); 5A1272 (Jolt) to be replaced with UB1270 (UPG). P5-12120 BAT-I2120 12 V, 12 AH, sealed. BPI2-12 (B&B Battery); PS-12120 (Power-Sonic); SA12120 (Jolt) to be replaced with UB12120 (UPG). PS-12170 BAT-12180 12 V, 18 AH, sealed. PS-12180 (Power-Sonic); 5A12180 (Jolt) to be replaced with UB12180 (UPG). P5-12180 BAT-12180 i2 V, 18 AH, sealed. PS-12180 (Power-Sonic); SA12180 (Jolt) to be replaced with UB12180 (UPG). PS-12250 BAT-I2260 12 V, 26 AH, sealed. BP26-12 (B&B Battery); PS-12260 (Power-Sonic); SA12260 (Jolt) to be replaced with UB12260 (UPG). PS-12550 BAT-12550 i2 V, 55 AH, sealed. PS-12550 (Power-Sonic); XSA12550 (Jolt) to be replaced with UB12550 (UPG). PS-12600 BAT-12550 12 V, 55 AH, sealed. P5-12550 (Power-Sonic); X5A12550 (Jolt) to be replaced with UB12550 (UPG). P5-12750 Discontinued N/A N/A P5-121000 BAT-121000 12 V, 100 AH, gell cell. PS-121000 (Power-Sonic); XSA121000A(Jolt) to be replaced with UB121000 (UPG). DF-52397:A • 12/29/06 - Page 1 of 10 I 40% 0% 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) 14.0 V 13.0 V 12.0 V 11.0 V Co C 10.0 V l 9.0 V 8.OV • __T_FT_ I I I I I I iiiiui -- ---.----- -- wo Rho I I E hi, 11hil mill IlNiii UIII1IIi!!L!iIIII iuurni•i uiiuii•ii• I I I I I I I I I I I I I I I I I I I POWER-SONIC lifleti thi MODEL Nominal Voltage V Nominal Capacity @ 20 hr. rate A.H. Discharge Current milk DIMENSIONS Wdth in. mm. Depth in. mm. 20 hr. Height in. mm. ht over terminal in. mm. Weight lbs. kg. PS-1250 12 5.0 250 3.54 90 2.76 70 4.02 102 4.21 107 4.1 1.9 PS-1270 12 7.0 325 5.94 151 2.56 65 3.70 94 3.86 98 5.7 2.6 PS-12120 12 12 600 5.94 151 3.86 98 3.70 94 3.86 98 8.8 4.0 P5-12180 12 18 875 7.13 181 2.99 76 6.57 167 6.57 167 12.8 5.8 PS-12250 12 25 1300 6.89 175 6.54 166 492 125 4.92 125 18.7 8.5 PS-12550 12 55 3000 10.25 266 6.60 168 8.20 208 9.45 240 39.7 18.0 PS-121000 12 100 5000 12.00 305 6.60 168 8.20 208 9.45 240 65.7 29.8 0 E. MEMEN ON -9 a 4_ .NEI NIAP P 04- 0 0 0 0 0 uuui••• -20° -10° 0° 10° 20° 30° 40° 50° 60° Temperature (Degrees C.) 0 80% at left: PS-1210000 Discharge Characteristics I 1.2 2:4 6 12 24 36481 2 4 6610 20 40 MINUTES Disch me HOURS Discharge Time Page 2 of 10- DF-52397:A • 12/29/06 ) 1 2 3 5 10 2030 60 2 3 5 10 20 30 minutes hours - Discharge Time © 20°C (68°F) 100% 90% Characteristic Discharge Curves 6.5 13 6.0 12 5.5 11 5.0 10 4.5 9 4.0 8 0 A Charging is NOT )) necessary unless 100% of capacity ! - . is required. 9 charging before N (41-F) use is necessary to help recover N full capacity. 4 Charge may - fail to restore full capacity. 40°C 30°C - -.- 20°C [E (104°F) (86°F) (68°F) DO NOT let batteries reach this state. -7 -7- 80% . 60% C) (0 um 40% 20% 0% 120% Effect of Temperature on Capacity 100% at left: PS-121000 Shelf-Life and Storage It is designed to be mounted a minimum of 6 inches (15.24 cm) below the fire alarm control panel (FACP). When both cabinets are surface mounted, the knockout in the bottom-right corner of the FACP will line up directly above the knockout in the top- right corner of this enclosure. This enclosure should be mounted in a clean, dry, vibration-free area, using the six holes provided. Note: The enclosure has 0.875 in. (2.2225 cm) knockouts which accept standard 0.75 in. (1.905 cm) conduit. FACP 6 inch minimum Conduit (15.24 cm) : I Battery/Peripherals Enclosure I I I I I I I I I I I I I I I I I I I This cabinet consists of a backbox with an integral, lockable door that is hinged on the bottom to swing down for access. 2.80 in. (71.12 mm) 7.73 (196.3 2.66 in. (67.564 mm) Left Side Door 24.125 in. (612.775 mm) 3.875 in. 7.730 in. I (98.425 mm) 16.00 in (406.4 mm) 7 96.342 m1 t 800 in. r3.2mmTi I I (101.6 mm) U I L. ._. 14.06 in. (357.124 mm) 15.00 in. (381 mm) CO 7.250 in. 1.2; in 23.750 in. (603.25 mm) (184.15 mm) (31.75 mm) Front (without door) Battery/Peripherals Enclosure PN 50295:B 07/24/2001 2.125 in. (53.975 mm) 10.00 in. (254 mm) 14.75 in (374.65 m I (a Firelffe iarms A P1WAY COMPANY D BG-12LX Addressable Pull Station DocLrnent 51094 Revision A2 ECN 00-032 01/14/2000 Description The BG-12LX Addressable pull station is a non-coded, dual-action manual pull station with a key-lock reset fea- ture. It provides Fire-Lite intelligent control panels with one addressable alarm initiating input. The addressable module is housed inside the pull station. Th BG-12LX is compatible with all Fire-Lite intelligent panels. The BG-12LX meets the ADA requirement for a 5-lb. maxi- mum pull force to activate the pull statioa. Operating instructions are molded into the pull statior handle along with Braille text. Molded Terminal numbers are also presert. Installation The BG-12LX Addressable pull station cat be surface mounted to an SB- 10 surface backbox or semi-flush mourned on a standard single-gang, double-gang or 4" (10.16 cm) square electrical box. The optional BG-TR trim ring can be used if the BG-l2LX is to be semi-flush mourned. Ratings Normal Operating Voltage: 24 VDC. Average Operating Current (LED Flash): 300 1.A. Temperature Range: 320 F - 1200 F (00 C - 490 Q. Relative Humidity Range: 10% - 93% non-condensing. Setting the BG-12LX Address The BG-12LX Addressable pull station is factory preset with address '00.' Set the address for the pull station by turning the rotary address switches on the addressable mod- ule mounted inside the pull station. Only one device per address is allowed. Multiple modules may not be set to the same address on the Signaling Line Circuit. Once the address is set, record it in the space provided on the prod- uct ID label located inside the pull station. ROTARY ADDRESS SWITCHES LED OPERATION U Normal: Flash RED Alarm: I I_I LED 1=1 0 0 Steady RED Note: LED is visible 14 11 2 I:throughi_'E 1 handle. I TENS ONES LII h47.0 c r1 0 If, during mounting of the pull station, the door be- comes detached, complete the following steps to reattach the door to the backplate. The door cannot be connected to the pull station if the unit is mounted to the backbox. Position the door and backplate side by side in the full open position. (i.e. 180-degrees with respect to each other.) With the backplate position fixed, move the door be- hind the backplate, as shown in the illustration, part A. Align the hinge posts and holes by bringing the door up to meet the backplate, paying particular attention to the 'keying' that occurs when the door's post hole is aligned to the backplate's hinge post. Refer to the illustration, part B. With the two pieces aligned and 'keyed' together, slide the holes down onto the posts. Refer to the illustra- tion, part C. Holding the backplate, close the door and backplate slightly to lock the door and backplate together. I I I I I I I I I I I I 111 HOLE POST I From FAG P SLC- I!o4 I I I I _ Operation To Next Addressable Device + Wiring If flush mounting, proceed to step 4. Mount the backbox before wiring it to the pull station. Before surface mounting the pull station, pull all wiring through the backbox and optional trim ring. Remove the appropriate amount of wire insulation. The pull station back plate is molded with a strip gauge to measure the amount of insulation to be removed. Connect the wiring from the addressable fire alarm control panel's Signaling Line Circuit (SLC) to Terminals l(-) and 2(+) on the BG-12LX addressable pull sta- tion. SLC polarity is critical for this connection. Connect the wiring going to the next device on the SLC to Terminals 1 and 2, again being certain to observe polarity. Open the pull station door; align the mounting holes of the pull station backplate to the backbox and screw into place. Tighten top and bottom screws. Set the address as described in 'Setting the BG-12LX Address' and write the address in the space provided on the label. V 9) Insure that the alarm switch is in the normal position. Close and lock the pull station door. I I I I I I I I I I Push-in and pull-down the handle where indicated to activate the station. The BG-12LX manual fire alarm pull station includes one SPST (Single Pole, Single Throw) N!O (normally-open) switch and the addressable mod- ule located inside the station. Pushing-in and pulling-down the dual action handle causes the N/O alarm switch to close. The word 'ACTIVATED' is displayed on the top of the handle when the pull station handle is Pushed-in and pulled-down. The activated handle can not be reset without employing the key-lock reset. To reset the BG-12LX pull station: 1) Insert the key and turn counterclockwise, 2) Open the door until the handle moves back into the 'NORMAL' position, 3) Close the door and lock it. Closing the door automatically resets the BG-l2LX to the 'NORMAL' position. I Note - Opening the pull station door will not activate or deactivate the alarm switch. ACTIVATED BG-12LX PULL DOOR ATTACHMENT STATION CAUTION! Install the Fire-Lite BG-12LX manual pull station in accordance with these instructions, applicable NFPA standards, national and local Fire and Electrical codes and the requirements of the AHJ (Authority Having Jurisdiction). Regular testing of the devices should be con- ducted in accordance with the appropriate NFPA standards. Failure to follow these directions may result in failure of the device to report an alarm condition. Fire-Lite is not responsible for devices that have been improperly installed, tested or maintained. For ADA compliance, if the clear floor space only allows forward approach to an object, the maximum forward reach height allowed is 48 in. (1,220 mm). If the clear floor space allows parallel approach by a person in a wheelchair, the maximum side reach height allowed is 54 in. (1,370 mm). Document 51094 Revision A2 ECN 00-032 01/14/2000 With the door and backplate aligned and keyed' together, slide the holes down onto the posts. Closing the door slightly locks the door and backplate together.