Loading...
HomeMy WebLinkAbout2864 WHIPTAIL LOOP; ; AS160125; Permit9/8/2020 AS160125 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2864 WHIPTAIL LP Permit Type: SPRINK Parcel No: 2091201000 Lot #: 0 Permit No: AS160125 Status: ISSUED Applied 5/10/2016 Approved: 6/29/2016 Reference No.: Issued: 6/29/2016 PC #: Inspector: Project Title: SR CARLSBAD OAKS ADD FIRE SPRINKLERS FOR NEW SHELL BUILDING START POINT IS 6" ABOVE FINISHED FLOOR Applicant: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY SAN MARCOS, CA 760-310-6122 Owner: TECH BILT CONSTRUCTION CORP P0 BOX 80036 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) JBalance($) 528 0 528 0 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 RECEIV 760.6024665 CEIV ~21 / WATER AVAILABILITY FORM JUN 2CiS SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: 2864 Whiptail Loop SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 2864 Whiptail Loop CITY: Carlsbad PHONE: ( 760 ) 310.6122 (Epic Fire Protection, Inc.) FAX NUMBER: (760) 798.0556 Largest Building (ft.2): ___ Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Whiptail Loop north of Caribou Ct. TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 163 PSI Hydrant Number (if applicable):H61668 Elevation of test: 324 Feet Date/Time of Test': Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 8,000 GPM Residual Pressure 136 PSI At peak demand , this water system is capable of providing a fire flow discharge @ 20 psi of greater than 8,000 GPM. Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: _ /j Titie/Org(PojectManager Date: 02/18/2016 AS 160125 2864 WHIPTAIL LP 2864 Whiptail Loop Fire Flow Analysis 16" 99 WFjJDTAIL LOOP a O Z o -< 0 I Z 'ii z C', C') EP'S SROO RD H61668 go FARADAY ST CT ES 16" FARADAY AV El Prepared By: Jennifer R. Mael, P.E. - MCS Date: Thursday, February 18, 2016 r"-*l,A7ERlAL DATA SUBM177AL SR. CARLSBAD OAKS BUILDING B ERIC FIRE PROTECTION, INC. 75 TURTLE POINT WAY SAN h1ARCOS, CA 20S (700)310-GI22 FAX(7O)78-O55 AS 1 4012T (37 (37 rc44.5 1-5/16' (34 r,n) 2-7/fl' - (40 1-3/4' (44.5 'in) January 24, 2013 Sprinkler 120a Sprinkler 120b January 24, 2013 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp,com The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK500 is a fast response fusible element type sprinkler designed for early fire suppression. With a 14.0 (202 metric') nominal K-Factor and special deflector, this sprinkler produces large, high-momentum water droplets in a hemispheric pattern below the deflector. This permits penetration of the fire plume and direct wetting of the burning fuel surface while cooling the atmosphere early in the development of a high-challenge fire. Viking VK500 ESFR Pendant Sprinklers may be used in the protection of ordinary types of storage. However, they are primarily intended to protect the following types of storage, which tend to produce severe-challenge fires: palletized and solid pile storage and single, double, multiple row, and portable open rack storage (no open-top contain- ers or solid shelves). Viking ESFR Pendent VK500 Sprinklers provide protection of most common storage materials, including: —Encapsulated or unencapsulated Class I, II, Ill, and IV commodibes'. —Cartoned and uncartoned unexpanded plastics'. —Cartoned and uncartoned expanded plastics'. Seat for Sprinkler 11350: Stainless Steel UNS-S31603 Seal and Insert Assembly for Sprinkler 10284: Capper UNS-C11000 and Stainless Steel UNS-530400 Belleville Spring Seating Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Stainless Steel IJNS-531603 Trigger and Support: Stainless Steel UNS-S31600 Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint. Ejector Spring (Sprinkler Base Part No. 11350 only): 17-7 Stainless Steel Ordering Information: (Also refer to the current Viking price list) Order ESFR Pendent Sprinkler VK500 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A Temperature Suffix: 165 'F (74 C) = C, 205 'F (96 'C) = B For example, sprinkler 10284 with a Brass finish and a 165 'F (74 'C) temperature rating = Part No. 10284AC. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories section of the Viking data book.) *Refer the Approval Charts and Design Criteria on pages 120c-d for cULus Listing and FM Approval requirements that must be followed. In addition, some storage arrangements of rolled paper, aerosols, and rubber tires may be protected by Viking ESFR Pendent Sprinkler VK500. LISTINGS AND APPROVALS cULus Listed: Category VNWH FM Approved: Class 2008 - NYC Approved: MEA89-92-E, Volume 18 Mvds VdS Approved: Certificate G4010001 CE Certified: Standard CUAP11.03/03, EC-certificate of conformity 1725-CPD-H0005, ETA-10/0306 The 10284 and 11350, VK500, ESFR Pendent Sprinkler Assembly conforms to the provision of CUAP11.03/03 standard, CUAP11.03/03 approvals are provided by: FM Approvals Ltd. 1 Windsor Dials Windsor, Berkshire, UK. SL4 I RS Approval Certificate No. issued December 20, 2010. NOTE: Other International approval certificates are available upon request. Refer Approval Chart 1 and Design Criteria on page 120c for cULus Listing requirements that must be followed, and refer to Approval Chart 2 and Design Criteria on page 120d for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2000. Minimum Operating Pressure: Refer to NFPA 13 or FM Global Loss Prevention Data Sheets. Maximum Working Pressure: 175 psi (12 Sm). Fontory tested hydmrtafirwlly to 500 psi (34.5 bar). Viking Technical Data may be found on Thread size: 3/4" (20 mm) NPT Nominal K-Factor: 14.0 U.S. (202 metric") The Viking Corporations Web Site at "Morris K-factor measurement shown is when pressure is measured in bar. When pressure http:Jlwww.vikinggroupinc.cOm. is measured in SPa, divide the metric K4actor shown by 10.0. The Web Site may include a more recent Overall Length: 2-7/8' (73 mm) edition of this Technical Data Page. Deflector Diameter: 1-3/4 (44.5 mm) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 Form No. F_060198 Replaces page 120a-f, dated February 17, 2012. (Revised Verband der Sachversicherer to SciradenverhOtung Sprfr'itrier 10284 sheen tprtnkter 11350 shown Figure 2: ESFR Pendent Sprinkler VK500 Dimensions TABLE 1: AVAILABLE SPRINKLER TEMPERATURE Sprinkler Temperature Sprinkler Nominal RATINGS AND FINISHES Maximum Ambient Frame Paint ClassIfIcation Temperature Rating CeilIng Temperature Color Ordinary 4- 165 'F (74 'C) 100 'F (38 'C) None Intermediate5 205 'F (96 'C) 150 'F (65 'C) White Sprinkler Finish: Brass Footnotes The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to spec/Sc installation standards. 'The intermediate temperature rating is available for Sprinkler Base Parr No. 10284 only. M I (ooL2c Wrench Fiat Protective 4 Sprinkler Cap 00, E .: ii ~-- Use Side 4 for ESFR Pendent <14.0 Sprinkler VK500 Figure 1: ESFR Pendent Sprinkler Wrench 13635W/B January 24, 24, 2013 Sprinkler 120c NIKJNG* :iiu'7..w- ESFR PENDENT SPRINKLER VK500 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49UttB Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart I (UI) EtaI-I4 Pendent bprltiklerVK58l) i- r V LL Moxlnmru 7h I-'t ('Li btj Ww 't-2 In Base Part umber' SIN NP1' Thread Sow Nominal Nominal Overall Length Listings and Approvals" (Refer also to Design Criteria below.) N Inches mm U.S. metric' Inches rem cULus' NYC' VdS LPCB CE' 10284 VK500 3/4' 20mm 14.0 - 2-7/8 73 Al, Bl 11350 VK500 3/4 20 mm - 202 2-7/8 73 Approved Temperature Ratings Approved Finish A - 165 'F (74 'C) B -200 'F (96 'C) 1 -Brass Footnotes Base part number Shown. For complete part number, refer to the price fist- 2 Metric K-Factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-Factor shown by 10.0. 'This chart shows listings and approvals available at the time of printing. Other approvals may be in process. 'Refer to the latest standards of NFPA 13 and the latest VdS standards. 'Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 'Accepted for use. City of New York Department of Buildings. MEA 89-92-E, Vol. 18. 'CE Certified. Stiredani Ci 1AP11,03103, EC-cerfihmnru rrt vrrefnrmity 1735 i'Pfl I-t110/15, QTA 1n/npa, DESIGN CRITERIA (UL) (Also refer to Approval Char) I above) cULus ListinQ Reoulrements: ESFR Pendent Sprinkler 10284 is cULus Listed as indicated in Approval Chart I for installation in accordance with the latest appropriate NFPA stan- dards (including NFPA 13) for ESFR Pendent K14.0 (202) Sprinklers, for: - Protecting rack storage of certain specified materials up to 3511 (10.7 m) high in buildings with 406)12.2 m) high ceilings with NOin-rack span- k/em. NFPA 13 Indicates the following for ESFR pendent sprinklers having a 14.0 nominal K-Factor: Position the deflector a maximum of 14" (356 mm) and a minimum 016" (152 mm) below the ceiling. - The minimum area of coverage allowed per sprinkler is 64 ft' (5.8 m') per NFPA 13. Maximum Rector Ceiling Slope: 2 in 12 (167 mm/rn or 9.5 degrees). Sprinkler Position: Approved for use only in the pendent position. Align the deflector parallel with the ceiling or roof. System Type: Wet systems only. Deflector Distance from Walls: At least 4 (102 mm) from walls, and no more than one-half the allowable distance permitted between sprinklers. Clearance from Deflector to Top of Storage: At least 36 (914 mm). Maximum Distance Between Sprinklers: The maximum area of coverage allowed per sprinkler is 100W (9.3 m')". - For buildings over 30 ft (9.1 m) high, spacing between sprinklers and/or branch lines mast be from 8 to 10 11(2.4 to 3.1 m)". - For building heights up 10306 (9.1 m), the spacing allowed between sprinklers and/or branch lines is8 to 12 8(2.4 to 3.7 m), provided the area covered per sprinkler does not exceed the maximum 1006' (9.3 ma) allowed". Refer to the Installation Standards for permissible deviations from the maximum sprinkler spacing rules above, to eliminate obstructions created by trusses and bar joists when using ESFR sprinklers. Minimum Area of Coverage: The minimum area of coverage allowed per sprinkler is 64 92 (5.8 m'). Note: If the ceiling is beam and girder or panel construction, locate sprinklers in the bays rather than under the beams. IMPORTANT: Always refer to Bulletin Form No, F_091699 - Care and Handling of Sprinklers. Viking ESFR Pendent Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest standards of VdS, NFPA, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, ordinances, and standards whenever applicable. Sprinkler 120d January 24, 2013 "IIJ II(JI1G ESFR PENDENT SPRINKLER VK500 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs(@vikingcorp.com ppgva! Chart 2 (FM). Cl kite p ngnP dartOpilill 1(586 ri Mulumumlis k'tat (12 ha) wwp A X tm,.inuntirtppOnui2l Base Part NPT Thread Size Nominal K-Factor Overall Length FM Approvals" Number' SIN (Refer also to Design Criteria below.) Inches mm U.S. mettle' Inches mm 10284 VK500 2/4' 20 mm 14.0 - 2-7/8 73 Al, BI 11350 VK500 314" 20 mm - 202 2-7/8 73 Al, BI Approved Temperature Ratings Approved Finish A - 165 'F (74 'C) B -205 ¶ (96 'C) 1 - Brass Footnotes Base part number shown. For complete part number, refer to the price list 'Metric K-Factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-Factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. 'FM Approved as a quick response pendent Non-Storage sprinkler and also FM Approved as a quick response pendent Storage sprinkler. Refer to Design Criteria below. DESlciNGf4l'PERIA-t-M (Also rtsfer Lu Apprra.'al Clinrt I irh'i v FM Aoeroval Requirements: Sprinkler VK500 is FM Approved as a quick response pendent Storage sprinkler as indicated in the FM Approval Guide. - For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheds (including Data Sheets 2-0 and 8-9). Sprinkler VK500 is also FM Approved as a quick response pendent Non-Storage sprinkler as indicated in the FM Approval Oxide. - For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers, Viking ESFR Pendent Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest applicable FM Global Loss Prevention Data Sheets (including 20 and 8-9), the latest standards of VdS, NFPA, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, ordinances, and Stan- dards whenever applicable, January 24, 2013 Sprinkler 120e The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Sprinkler Wrenches: Part No. 13635W/B (double-ended wrench - Use Side A. Side B is for use with 1(25.2 ESFR Pendent Sprinkler VK510) Available since 2006. Part No. 10285W/B (no longer available) Sprinkler Cabinet: Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION WARNING: Viking sprinklers are manufactured and tested to meet rigid requirements of the approving agency. The sprinklers are designed to be installed in accordance with recognized installation standards. System design must be based on ESFR design guidelines described in the latest edition of Viking technical data. applicable FM Global Loss Prevention Data Sheets, the latest NFPA Standards, the latest standards of (VdS) Schadenvertrtitung. the Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards whenever applicable. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinkler inoperative and will automatically nullity the approval and any guarantee made by The Viking Corporation. Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container. Never install sprinklers that have been dropped or damaged in any way. Such sprinklers should be destroyed immediately. NOTE: Wet pipe systems must be provided with adequate heat The sprinklers must be installed after the piping is in place to prevent mechanical damage. Before installing, be sure to have the appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. With the sprinkler contained in the plastic protective cap, apply a small amount otpipe-joint compound or tape to the mate threads only, white taking care not to allow a build-up of compound in the sprinkler orifice. Use ONLY sprinkler wrench 10285W/B or 13635W/B (shown in Figure 1) for installing ESFR Sprinkler VKSOO! With the sprinkler contained in the protective cap, install the sprinkler onto the piping by applying the sprinkler wrench to the sprinkler wrench flats only, while taking care not to damage the sprinkler operating parts. DO NOT use any other type of wrench, as this could damage the unit DO NOT use the sprinkler detector or fusible element to start or thread the sprinkler into a fitting. DO NOT exceed 50 ft. lbs. of torque (hand tight, plus approximately two full turns with the wrench) to install these sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the Installation Standards. Make sure the sprinkler has been properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Immediately replace any damaged units, using the special spnnkter wrench only. After Installation and testing and repairing of all leaks, remove the protective caps from the sprinklers. DO NOT use any type of tool to remove the cap. Remove the cap by hand: turn it slightly and pull it off the sprinkler. When removing caps, use care to prevent dislodging or damaging sprinkler ejector spring and fusible element. THE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! System design must be based on ESFR design guidelines described in applicable FM Global Loss Prevention Data Sheets, the latest standards of (VdS) Schadenverhutung, the National Fire Protection Association, and the Authorities Having Junsdictron. All requirements of recognized sprinkler system design standards apply to systems utilizing Viking ESFR Pendent Sprinklers. NOTE: Viking recommends installing one style of sprinklers (either pendent or upright) throughout ESFR systems. However, provided the fusible elements are installed within the distance below the ceiling allowed by the Installation standards, and when acceptable to the Authority Having Jurisdiction, Viking considers the practice of mixing upright and pendent ESFR sprinklers to be acceptable. Sprinkler 120f January 24, 2013 N1K1W*j ESFR PENDENT SPRINKLER I VK500(K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com 6. INSPECTIONS, TESTS AND MAINTENANCE NOTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the NFPA standard that describes care and maintenance of sprinkler systems. In addition, the Authorities Having Jurisdiction may have additional maintenance, testing. and inspection requirements that must be followed. A. The sprinklers must be inspected on a regular basis for corrosion, mechanical damage. obstructions, paint, etc. The frequency of inspections may vary due to corrosive atmosphere, water supplies, and activity around the device. B. Sprinklers that have been painted or mechanically damaged must be replaced immediately. Sprinklers showing signs of cor- rosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if necessary, replaced after a specified term of service. For Viking ESFR Pendent Sprinklers, refer to the Installation Standards (e.g.. NFPA 25) and the Authorities Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Sprinklers that have operated cannot be reassembled or reused, but must be replaced. When replacing sprinklers, use only new sprinklers. C. The sprinkler discharge pattern is critical for proper fire protection. Therefore, nothing should be hung from, attached to, or otherwise obstruct the discharge pattern. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service. notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. Remove the system from service, drain all water, and relieve all pressure on the piping. Using the special sprinkler wrench, remove the old sprinkler and install the new unit Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct orifice size, temperature rating, and response charac- teristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. Place the system back in service and secure all valves. Check the replaced sprinklers and repair all leaks. E. Sprinkler systems that have been subjet to a fire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced. Refer to the Authorities Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY The Viking Model VKSOO Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. 5. OPERATION During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and spnng assemblies to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler defector, forming a uniform spray pattern to suppress the fire. Porn, No. F_060198 Replaces page 120a-f, dated February 17. 2012. (Revised Verband der Sachversicherer to SchadenverhUtung) Viking Technical Data may be found on The Viking Corporation's Web site at http:IIwmw.vtklnggroupinc.com. The Web site may include a more recent Frame Casting. Brass UNS-C84400 revision of this Technical Data Page. Deflector. Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring - Exposed. Screw and Pipcap - ENT plated. tTNot for FM Approval. Ordering Information: (Also refer to the current Viking price list) Order Micromatic° and MicromaticNP5 Standard Response Upright Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffixes: Brass = A. Chrome = F, White Polyester = M-M/, Black Polyester = Id-/S. Wax Coated = C. Wax Over Polyester = V-/W. ENT = iN Specifications: Minimum Operating Pressure: 7 Psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatic rating: 500 psi (34.5 bar) Thread size: 1/2" NPT. 15 mm BSP. 3/4' NPT. 20 mm 8SF Nominal K-Factor: 8.0 U.S. (1152 metric"") Glass-bulb fluid temperature rating: -65 "F (-55 "C) Overall Length: 2-3/8" (60 mm) t cULus Listing. FM Approval. and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Metric K-factor measurement shown is in Bar. When pressure Is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Page lof 6 Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Micromatic° Standard Response Upright VK200 Sprinkler is a small. thermo- sensitive, glass-bulb spray sprinkler available in several different finishes, temperature rat- ings, and K-Factors to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant FM Global has no approval classification for Polyester coating as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 fVdSj VdS Approved: Certificates G414013 and 0414014 LPCB Approved CE Certified: Standard EN 12259-1. EC-certificate of conformity 0832-CPD-0021 ICE NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and UL Design Criteria on page 4 cULus Listing requirements, and refer to Approval Chart 2 and FM Design Criteria on page 5 for FM Approval requirements that must be followed. 3. TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax; 269-818-1680 Email: techsvcs@viklngcorp.com Temperature Suffixes: 135 "F (57 'C)=A, 155 "F (68 "C) = B, 175 "F(79 "C) = D. 200 "F (93 "C)= E. 212 "F (100 "C)= M, 286 "F (141 "C) = 0,360 "F (182 "C) c H, 500 "F (260 "C) = L, OPEN = Z (PTFE only). For example, sprinkler VK200 with a 1/2" thread, Brass finish and a 155 "F (68 "C) temperature rating = Part No. 18268AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). D. Wrench for Wax Coated Sprinklers: Part No. 13577W/B" (available since 2006) "A 'I," ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-tread capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromaticu Standard Response Upright Sprinkler VK200 is available through a network of domestic and international distributors. See The Viking Corporation web Site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_032814 18.03.04 Rev 16.1 Replaces Form No. F_032814 Rev 15.1 (Removed Stack PTFE) IForm No. F_032814 16.03.04 Rev 16.1 Page 3 of 6 Page 4 of 6 'lIKING® MICROMATIC° STANDARD RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.cOm TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINIVE$ max asslflofl Ordinary 135 'F (57 'C) 100 'F (38 'C) Orange Ordinary 155 'F (68 'C) 100 'F (38 'C) Red Intermediate 175 'F (79 'C) 150 'F (65 'C) Yellow Intermediate 200 'F (93 'C) 150 'F (65 'C) Green High 286 'F (141 'C) 225 'F (107 'C) Blue Extra High 360 'F (182 'C) 300 'F (149 'C) Mauve Ultra High' 500 'F (260 'C) 465 'F (240 'C) Black Sprinkler Finishes: Brass, Chrome. White Polyester. Black Polyester, and ENT Corrosion-Resistant Coatings': While and Black Polyester in all temperature ratings. 64-IT in all temperature ratings except 135 'F (57 'C). Wax-Coated Brass and Wax over Polyester' for sprinklers with the following temperature ratings: 155 'F (68 'C) Lt. Brown Wax 175 'F (79 'C) Brown Wax 200 'F (93 'C) Brown Wax 286 'F (141 'C) Dk. Brown Wax5 Footnotes The sprinkler temperature rating is stamped on the deflector. 'Based on NFPA-13. Other limits may apply, depending on lire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers. or similar enclosures with flannel operating temperatures above 300 'F (149 'C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (149 'C). response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts, These tests cannot and do net represent all possible corrosive envimnmenls. Prior to installation, verify through the end-user that the coatings ate compat- ible with or suitable for the proposed environment, For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT. For ENT coaled automatic sprinklers, the waterway is coated. 'Wax melting point is 170 'F (76 'C) for 286 'F (141 'C) temperature rated sprinklers. Protective Sprinkler Cap "-'---.--_..,. Wrench Flat Figure 1 Standard Sprinkler Wrench 101196WlB Form No. F032814 16.03.04 Rev 16.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4.. a no At_ ma,Maxt"umL135 Sl (4.12 "or; WWP4 , Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvats° Base Part SIN _______________ ____________ IRefer also tnULDesign Criteria.) Number' NPT j BSP U.S. metric' Inches I mm cULus' VdS LPCB I CE Standard Orifice 18268° VK200 1/2' 15 mm I 8.0 115.2 2-1/4' 57 Al, 84, CS, 03, ES P2 A2, 64 F3 - 18263 VK200 3/4' 20 mm 8.0 115.2 2-1/4' 57 Al, 64, CS, 03, ES .42 A2. 64 F3 - 18266 VK200 - 20 mm 9.0 115.2 2-1/4' 57 Al, 84. CS, 03.66 A2 A2. 84 P3 - 102200 VK200 1/2' 15 min 8.0 115.2 2-1/4' 57 Al, 84, CS, 03,66 P.2 A2, 84 F3 F3 10141 '/1(200 3/4' 20 min 8.0 115.2 2-1/4' J57 Al, 84, CS, 03,56 .42 .42, 64 P3 F3 10169 '/1(200 - 20 mm 8.0 115.2 2-1/4' j 57 A1,64, CS, 03, ES .42 A2, 64 P3 F3 Approved Temperature Ratings A - 135 'F (57 'C), 155 'F(68 'C). 175 'F (79 'C). 200 'F (93 'C), 286 'F (141 'C), and 360 'F (182 Approved Finishes Cl 1 - Brass, Chrome. White Polyester" and Black Potyestera axd20O'F(93'() 155 'F (68 'C), 175 'F )79 'C), 2 - Brass. Chrome. White Polyester', and Black Polyester' C - 286 'F (141 'C) 3- Brass and Chrome - 500 'F (260 'C)r 4-Wax-Coated Brass and Was Over Polyester' E - 155 'F (68 'C), 175 (79 'C). 200 'F )93 5- High Temperature 200 OF (93 C) Wax Coating (corrosion resistant): maximum ambient 1cm- 'C). 286 'F (141 'C). 360 OF (182 'C). and 500 erawre allowed at fi ( 65 (260 'C)' 6 - ENT' F - 158 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C). 286'F (141 'C), and 360'F (182 'C) Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor shown is for use when pressure is measured in bar. When pressure in measured in kPa, divide are metric 1<-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Chock with the manufacturer for any additional approvals. 'Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant, 'Other Colors are available On request with the Same Listings and Approvals as the standard colors. Sprinklers of Ultra-High temperature ruling are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 'F (149 'C). Whew the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (149 'C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. ° CE Certified, Standard EN 12259-1. SC-certificate of conformity 0786-CPD-40137. 0786-CPo-40142, 0786-CPO-40177, 0786-CPO-40182. 0932- CPD-0021. and 0832-CPD-2003. 'The 112' NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. o MED Certified, Standard EN 12259-1. EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. $lGNRlTERlA'iJf' fr ar whP]qoGrusSChu't 'v cULus Listing Reouirornents; The Viking Micromatic" Standard Response Upright Sprinkler \1K200 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. - Designed for use In Light, Ordinary, and 8055 Hazard occupancies. The sprinkler installation roles contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F 032814 16.03.04 Rev 16,1 Page 5of6 4JIKING® The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ai'€1 C O 4E44)7'4 ,'. urn )ec F' Mlcromatti Standard Upright Sprinklers. ' I ,e,ponse .L Maxlrnum 17Sl (12 b 'r} WWP en' ax Sprinkler Base Thread Size Nominal K-Factor Overall Length FM Approvals' SIN Part Number' Inches mm (Refer also to Design Criteria below.) NPT BSP U.S: metric' Standard Orifice 18268' VK200 1/2' 15mm 8.0 115.2 2-1/4' 57 Al, B2, Cl, 03 18263 VK200 3/4' 20 mm 8.0 115.2 2-1/4' 57 Al, 82, Cl, 03 18266 1/1<200 - 20 min 8.0 115.2 2-1/4' 57 Al, B2, Cl, 03 1/2' 15mm 8.0 115.2 2-1/4' 57 Al, 62. Cl, D3 10220' VK200 10141 VK200 f_3/4' J 20 mm 8.0 115.2 2-1/4' 57 Al, 62. Cl, 03 10169 VK200 j - 20 Imm 8.0 115.2 2-114' 57 Al, 62, Cl, 03 Approved Temperature Ratings A-135'F)57'C), 155'F(68'C),175F(79'C),200'F(93'C). 286 'F (141 'C). and 360 'F (182 'C) Approved Finishes O - 135 'F (57 'C), 155 'F (68 'C). 175 'F (79 'C), and 1 - Brass, Chrome, White Polyester', and B/orb Polyester' 200 'F (93 'C) 2- Wax-Coated Brass (iorrosien resistant) C-500'F(260'C)t 3-EN1' 0-155 'F (68 'C), 175 'F (79 'C). 200 'F (93 'C). 286 'F (141 'C). 360 'F (182 'C). and 500 'F (260 'C)' Footnotes Base part number is shown. For complete part number. refer to Viking's current price schedule. 'Metric K-factor shown, is for use when pressure is measured in bar. When pressure is measured in kPo. divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 'Other colors are available on request with the same Approvals as the standard colors. 'Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 'F (149 'C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is sign/Scantly reduced below 300 'F (149 'C). the response time of the Ultra-High temperature rated sprinkler may be severely retarded- 6 FM approved as corrosion resistant The 1/2' NPT Large Or/ice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13 )'Jill (AdsotoforluApproaiChart.) u - FM Aoeronat Realt/tgtflflalt3' The Viking M,cromal,c° Standard Response Upright Sprinkler VK200 is is FM Approved as standard response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Streets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_0&0614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD. VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Page 6 of 6 NIIKJNG MICROMATICO__STANDARD 1 I' RESPONSE UPRIGHT SPRINKLER VK200 (K8,0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler wrench 13577W/5 ° must be used for installing wax coated sprinklers. Step 1: Carefully slide the wrench sideways around the deflector, ensuring engage- ment with the sprinklger wrench flats. thltQl.it Wax Coated Upright Sprinkler ra -- **A 112" ratchet is required Step 2: Carefully press the wrench downward (not available from Viking) and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 13577W/B for Wax Coated sprinklers MICROMATIC° STANDARD RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) Form No. F_032814 16.03.04 Rev 16.1 Form No. F_032814 16.03.04 Rev 16.1 Replaces Form No. F_032814 Ron 15.1 (Removed Black PTFE) 1.530 1.442 1.380 1.98 1.00 1.728 2.203 2.705 3.334 4.310 1.682 2.157 2.635 3.260 4.260 1,610 2.067 2.469 3.068 4.026 3,44 2.78 1.66 1.00 1.00 1.00 1.00 1.00 1.00 1.00 The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems in commercial and residential construction, Bull Moose Tube has added Eddy Flow to its comprehensive line of sprinkler pipe products. Eddy Flow is a specially engineered replacement for schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL listed (for U.S. and Canada) for roll grooving and welding for use in fire protection COMPARISON systems with a working pressure of 300 psi or less. Please check with appropriate sources for up-to-date listings and approval information. As an added benefit, it is more economical to use than schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's larger ID provides an opportunity for downsizing and further cost savings. 11/4 1.660 1 1/2 1.900 2 2,375 2 1/2 2.875 3 3.500 4 4.500 * Corrosion Resistance Ratio TS Dual Certified to AS TM A135 and A795. FM Approved for roll grooved, and welded, and plain-end application in wet systems. UI. Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. UL Listed (for US and Canada) and FM Approved for use with Victaulic® FI7 Fittings in plain end applications. Lightweight. saves shipping costs, and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Floor stock available in various lengths produced in Casa Grande (AZ), Gerald (MO), and Masury (OH). Also can be ordered in custom lengths.. Can be used for wet and dry* systems. 'Eddy Flow can be hot dipped galvanized to meet FM's requirement for city systems. PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturers instructions for the specific fitting used. Q A. 1819 Clarkson Road For additional information, c®us Chesterfield, MO 63017 contact your salesperson today at LISTEO 3 (800) 325-4467 (800) 325-4467 or (636) 537-2600 BULL MOOSE TUSE COMPANY F(: (636) 537-2645 in the USA, or from Canada _______ \.\'\)r'\r/bt! lrnoosetube,coni call (800) 882-4666 <8> A 66 company e-mail esQfflmoosetu. e corn APPROVED All information contained herein is accurate as lrnown at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of tO Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has a Pressure Rating of 300 Psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-135 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 11 Eli j ma 1.461 1.083 70 11/4 2.070 1.418 51 11/2 2,547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1.00 1.00 11/4 1.00 1.00 11/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems Chesterfield, A. C®US C!~' eld, MO 63017 contact your salesperson today at 1819 Clarkson Road For additional information, BULL MOOSE TUBE COMPANY (800) 325-4467 (800) 325-4467 or (636) 537-2600 LISTED F (636) 537-2645 in the USA, or from Canada _______ II moosetube.com call (800) 882-4666 A company APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without lncuning obligation. 8/08 tqCoFire & Building / Products Technical Services:Tel: (800) 381-9312/ Faac (800) 791-5500 nrnjw.fyw-tife.0001 Grinnell Grooved Fire Protection Products Figure 772 Rigid Coupling - Patented General Description 1J t-- VdS (Ii" (1I Son Finn erolnntmOn FM Sobnrinal SIren] for Prnor.orn olaeng dod t.islingcspproear hrtormatloe floFtguro772R/gdCgpoindesarigitjorrehp tionfy 91510119 a6og the cirtualdonoce of the pipe 91010001 Rpi/ conitbeps are plelelod toc dry pipe and ba/a9ffth. Bigot Caryfogs arnaprnrerd01able nlenrod at oreg pipe and aroaee01lr01rria/anend/setov.nldlrrg.trrno.dbigor elrgthnm.1ticra11a560tp105ncrmsptn500peig (34471d'a)depeedilyocpipeseearslwoltoridroess when nod.itmeprmttecf6nsmro pigblC00110115salnm0000mettdedtordtypi000lol 0neoor2ttp60a60tos WAOM The //pare 772 Rigid Gafipe dencrrbe/ liermil nredded/OP0/arsdroaind/ditcorrrp/aoorw/e lfindoaxoortaosseddsW/ethc/SphratkW/n/arofi o/bhebidod/beePreledionA550ciztior.ifa//hina to the standards of any 011lOb- aoitrorioes basing gird/n/binS /a,lhoe to do so otajr legal the pohblneaoce0110lo/eoioo. The ohereric rogtelsltir blrmain0/rhog thai-fire preadir015J/Sero and defeats elpmprfbperpong conoltiern The inisaltirrg eorftr000, or Sprint/er maroisiaurminooinbecorr/dedfsithargrqaeetiorec Technical Data Fipoe: 772 Sloan: 1IC-t7 tippronnlrt UL. FM, ULC. VdS. and LPCO: See fire Protection Soborittal Street for enact Listing / 6/Orson] information. Pager 1 f 2 HoonioRi One/to iron conforming to n/TM A-536. 0,0/0 65-45-12 peotedJno Ceallegra 0/sri-lend orange paint -Fire brigade red (optional) rrgo-teao paint - Hot dipped galvanized conforming to 051111 6-153 Bolt/Nodrt Gad, lead Bolts - cordornnrrrg to n/TM A-183. Zinc Plated. (Min. Tensile = 110.990 psl/758422 Pita) Metric - conformingtoASTM P56/tO Gasket (specify when ordering) Grade 0 [PUMA violet color code arnbierrtto.tb27f)*627C)tortirnprotection systems. Not roconrnrended for hot orator sysfeels. - Tri-seai(GradeTleP0M).greeecotorcode for 050 in iffy pipe or freezer systems. - Pretobriented (Grade 0 EPOMS) (See 0010 Spoof TPP1OSS for aid In selecting proper gad/el) Ordering Procedure When placing an order. in/irate the lug product naere.Ploasespecity0regoaetity,figamoeoorber, type 01 gaslret, Grade A EPOMA, Prelobricoted )GradeTh'EPOMA)orGrade"EEPOMTri-Soal, and size. GhiIn68Gr0010]Plp6rgPlgdxto,00tso,axenconns and 0/leo prodo0s are asaitabie onnogtloat 110 US..Caoada,aodiotenratialalyornsglraoefosrtr etdictribsbaradtos.Yoorrrayn,itedirncbyorratt 215-365-0700 for the dicSlbofornearerayoa. Care and Maintenance The owner in responsible for the rsaspection. fooling, and nhairll000rrce of their fire protection system and deeices in accordance with the nppticot/estandardsof thebatior'alflrn Protection Association (e.g.. SF65 25). in addition to the standards of any authority Pacing jurisdiction. Theinsfatliogconteactororprodoctnrnoolactorer July 2004 siroold he contacted lefatine to any questions. Any linpainneof nnea be immediately corrected. It is recommended that automatic sprinkler systems ItO inspected tested. and maintained by a qualified topped/on Service. Limited Warranty P9031,38 rrtars/owt by Spot Fire Prodrois are e,anorrledadefytoomeorigisli8rgerlamon(10)ynnrs agait53de199irn1nt0mn12d/wodeitaosfmlpwtreetaid torardpmapmfyindsfd/andeadrabrolonlereomrat menrIdsns/aTf500000mey008010irnfeol(lg)yenhs tree, date of stipmmmf by Tyre Pie Pr50 No snnn010y is giono for pro/ads or carny0005ts o6frTproRrnPnndr0seriorpo08/Ssarolrorrponerds onnrod/tl.nrbsfretmtleOenotbemkrstated.esnitairrof. me/it/of or repaired 6 aatnniosol or/dr apple/abE Standards of the 0050,0/ fire Protection darstari/titor )O90A(.aiabor the dar/arsisofalrpcfirordoiololdios fin/org Jto46tbar. frbon94 found by lyre Fire Pd/sOS lobe deledise dial be p.8101 repoilncf Or hnpbcolatTycoFirePtodrels'sdeopbol. lyre fire toanlneetorlaoyudreroblgnitrom'mcolrrwoinewinr thre Sole of p02/acts or pelts 0190/006 Tyco Pie PI0/01lssbnlno]ber0,pod/blefursfoiildersyslern dooignelsrsorlinssaaburimetrpfeteirdratoo54 roptod by Boierorflrgea'serobcoetn/tirear IN 003 SuSHI 5-I/ti li-Cl) 1518 PRODUCTS do U/at_/a/it CTh1111501.TORLSIT1ICTUABSSTYOR Ierr5NfDfl80LEGALfl80RY,[03OUitThL trlUl0ECt',SPECtAL0g030680llI/dTlAI0pz/A, P03W/P/S BUTPlOTUMttEOTOI.P50R0lMttlES, ItEG,f7lflt,p5S0FVd'StIIERTYtORREPRODUCTS wpspdrooistaLanhxtruEPf99sstLpryor9.Etl 001/0685.0110 0/ 90 EbBdT SHALL T'rlXt ROE ppwucl7uustjrysgTMlndpuhoudTyouul 10 OhIO SOLES PP/ES ANYAMD AU OVER IMpLo68fNeNGWAR68qp Af6flCP/°NTADF&.TJ /80 FITNE38 F08 / TFPISSO Puge2or2 TFPlOSO Figure 772 Grooved Coupling 0A - Mainnlon, and/able gap between pipe no/ar Minimon, gap 0. Mao/moor pr005ren and end lead are loIn] freer on roads based On standard weigol 51001 P150. Pressure ratings and end loads may dilleron oerer pile nalenais and/or wolf efidroless. Caeoast Tyce Floe Products for details. Sod Fire Prnfn5000 Equipment 5obrnlftat Spool for Using and Approsolt pressure 1011095. -- Gold color ended metric bolt woes are available open request. O Mao End Gap is for 501 grooved standard woigno pizA Values for rod grooned pipe orb be 311110101 oaf 9,00500. F/gore 772 Rigid Couplings base ondrrb-llowrluo Fenlorn orgnpperg leone along 11,0 calopf ing reps In sizes 1'/ .4'. 011501 make the Figure 772 ped050y, soiled for an5 05e0 inotata000s where the hOd/hOOd of notation is greatest. Thin featare may ebonnouhe the need of ff0100 5009010 00 009000 me 00110101,00010 ieorna.500 ri/folly dod gripping torSo saving 1000 and 0ma General Nolan: It is Ore cteSigne?5 responsibility to soled pnoducfs so/able for the intended 500,100 and to ensure ISO Oral pressure rarrngs and portooeaoce data 5 oofeoseedod. Always read and understand 000 installation 9001 0050505005 (Ifarl000). None, remoco any piping otre00000h or cornea or modify any piping defi010eelos without FoOl depresSorialog 000 droining Ore 0051000 tdaterih and gad/el selection sonosad be 0dfiOd to be eafepalible 10,0,00000/a aclpt050san. Certified Company TYCO FIRE PRODUCTS. 451 11001ff Caonne A0000e Laos/are. Pennsylcnsia 59946 Printed U.S.A. Pipe Mao.'i End Gap Mao,t Pressure Maar.t En/Load foOnrina] Dimensions oil . -- Net WI. O.D. A 8 C Sine 0001105 Inches p i Lbs. Inches Inches 00105 Size M. rnrel h//p N anon mm IhIIII 0,a, Kg- 1.560 0.06 300 649 2,75 4.38 1.81 REc2'/." 1.0 42,4 1.5 7068 2.8.87 69.9 111.3 46.0 Mt0ar57 0.5 1.900 0.08 500 1417 3.00 4.62 1.81 Ib'o2W LO 48.3 2.0 3,447 6,303 76.2 1a7.3 46.0 /410057 0,5 2 2.375 0.13 500 2214 3.41 5.12 1.88 t/27x2W 1,5 60.3 3.3 3.447 9,848 86.6 030.0 47.8 Mt0re57 0.7 s IV 71 315 2.875 0.13 500 3244 3.91 5.63 1.88 '/,o2'/. 23 73.0 3.3 3.447 f4,430 99.3 143.0 47.8 M10re57 0.t 76.1...,. 3.000 0.13 300 7120 4.19 5.72 2.00 M10057 2,6 76.1 3.3 2.068 9,430 106.4 145.3 50.8 02 3.500 0.13 500 4.808 4.63 625 1.85 %x2W 2.5 88.9 3.3 3.447 21.387 1t7.6 158.8 47.8 714 P0 Sr 57 1.2 4.500 0.19 500 7.948 5.51 7.50 1.97 W n2W 35 114.3 4.8 3,447 35,353 147.6 190.5 50.0 11410ro57 0.6 i39.7. 5.500 0.19 300 7.127 7.02 9.72 2.06 M160103 139.7 4.8 2,068 31,701 079,3 246.9 523 3.4 5/63 0.19 300 7258 7.09 9.71 2.04 RE b3Y7 7.5 140.3 58 2.068 37417 180.t 246.6 51.8 0006483 3.4 165.1 7. 6.500 0.19 300 9.950 8.05 10.53 2.13 65160163 165.1 4.8 2.068 44.258 205.5 267.5 84.1 3.4 6.625 0.19 400 13,702 8.09 10.53 2.13 '/.7e3Y." 7.6 168.3 48 2.758 61,302 205.5 267.5 54.0 9416 ar83 3.4 6 8.625 0.19 450 26276 10.55 13.56 2.62 0iCx41,27 18.0 219.1 4,8 3,103 tt6.885 268.2 344.4 66.5 M20ae 121 8,2 10.750 0.13 250 22,679 12.84 16.41 2.62 1o6W 24.6 273.0 3.3 1.724 000,876 326.1 416.8 66.5 /424w 165 112 127 12750 0.13 250 31,903 15.41 18.84 2.62 27e 6W 42.0 323,8 3,3 1,724 141905 391.4 478.5 66.5 M24ar168 19.0 Grinnell Grooved Fire Protection Products Grooved Fittings General MateriaL Limited Cavtfrlgures:201 .210.219.250.260.5th. 510. Description 519. 5100E. 5015. 510S and 519S- Warranty See F.m Protection Ductile iron conforming to ASTM 0-536. Products manufactured by Tyco Fire Products are ![)O1S suhmnlnal Sheet tom Grade 65-05-12 warranted srolely to the original Buyer tar ten (30) LIIIJ Pressure IFaringaed Fabricated Steel* Figures 391. 392. 393. 312. years peirmedects is Llsseg/appmocal 313.321. 327.341 and 350 - Carbon Steel. whenimidlorand Property installed and =infainetil InlonnatrOn (Sees 17r -ntaro Schedule 40): under normal use and serve This warranty will (sizes r- tare Schedule 35). expire ten (3q) years from ANentshipmrtbyTyca conforming to ASTM A-53 Grude6 Fire Products. Nowanantyis gisen torproductsor Tlregroocedhlttingsprnsidearrecorrnnnical Protective Coatings: crmpnoents rnanulacturnd try companies not eeddlfrerentmnechndutehaegingdireehioo. - Nun-lead Orange paint fbyrm_TmpRmP80uconctcr adding 30 outer. reducing. or capping - Fire brigade red (optional) non-lead Panh pmduCtsaednomponeeatwhictr haneb000subject groovedpipingsystners. Greened fittings ndotdipted galvanized contornring to 853111 tomisuse irnpwperinstaltabon,cnrmsion,orwitish are available in durable ductile iron or A-lbS tam 001 been ir000ed, maintained, modified or fabricated steel as indicated. epinmdinxcocewdeapptleSrandarosot Note: Figure 5105 and 519S fittings are Ordering Ore National Foe Protection Association (NFPA). special shod radios fittings with smaller Procedure andfortlrestandardsetanyottrerhuthurrbeslearent center to end dimensions than Standard Jurisdiction. Materials found byTyco fIre Products gwonnd frttlngs. Depending 001110 size and When placing an order. indicate the tut product tnbedetnctioestrallbeeit5ermepairedurreplacod,at cnnpfing need. thrme may be intrrlereerresat narnn.Pleanespocitylrrequantity,ligurenumber. Tyro ttroPmodacts'sulroption. Tyco Fire Products the boll pads that require repositioning of the wall thickness, and size, neither assunres. nor authorizes any person to coupling orIentatIon, 1110 use et flange Grinnell Grooved Piping Products. valves. wnunretnritanyothorobtigabuniocantrectionaitlr adapters is not recommended truth Figures accessories and other products are available the suteolprodactsorpartsetproducte. Tycahre 5105 and 5192 lilllngs. Contact Ty- Hm throughorcothe u2.Canadaandentematinoafly, Prndusbalnot5orespcmrsibfetorsprintders'jsrern Products for details. through a network of distribubon centers. You designerrorsorinaccrrratoorincernptereinlorrrrebon WARNING nay write directly or call 215-363-0700 for the supplied 11y9nyer0r6crye?s represeortatines. The fittings described herein most be installed distributor nearest you. IN NO EVENT SHALL TYCO FIRE PRODUCES BE antiorainOinediocampliancercitlrtoisdoctanrent LIABLE IN COIOtPI8CT, TORT. STRICT LIABILITY Care as wall as with the applicable standards of r and o U6008 holY OTHER LEGAL THEORY. FOR National Fire Protectinndssocrafinn, in addition Maintenance INCIDENTAL INDIRECT, SPECIAL OR to the Standards otargrntheraothotitins barirrg jurisuhctiucc Failure lode so may impale the The owner is responsible for the inspection. UNTIED TO LABOR CtiAIIGES.REGABI)LESSOP peolerrnaoce of this dentin. testing, and maintenance 01 their Em protection hVIIETHOI1YCORREPROOUCTSWGSINFORMED The owner is responsible for maintaining their system and devices in accordance with the ABOUT THE POSSIBILItY OF SUCH DAMAGES. die protection system arra genres in proper appicablestandardscfttrnhlationalRmProtoction 8.6019 NOEVRNTSHAII1YCOAREPRODUCTS operating corrditiorr The installing conbaceor'or Association (e.g.. NFPA 25). in addition to the UABllJTY EXCEED AN hlrtOltltt EQUAL TO THE spflnfdermanulacnurershnuldbec000dedrrrith standards of any authority having jurisdiction. SALES PRICE any questions The rlrstaltingcuotractnror product manufacturer ITrOrfE8RUCO(M) Wn4NTY159q40ENVJJE.U0F should be contacted relative to any questions- NffAIBLALL,fl1Dil10RR4N11Et08MAI1B Technical Any impaienrent nrost be immndiatefycomrected. IMP'LIEP.INCLJJOINdi_WARRA91TIES.,E It is recommended that automatic sprinkler Data MERCH4O4TA8UYTY AN!) FITN,5fJYfl srmbemiped,motandmaintw.edby PAP1R3.RARFBNlPO. Approvals: a qualified Inspection Service. UL P91. ULC. VdS, and LPCO: Note: See Fire Protection Submittal Sheet for 0n3c1 Lithe0 lAppronal information- Page 1 of 6 Sepeembe, 2004 TFP1810 Page 2nO6 '1FP18rft Figures 201, 210, 219, and 260 Frgumn 210 -crrr--1 cmnc1 - Lcec Pbyrre 260 orgy. nnnne'rrnr Fran O..rael marry. en on-rn mc flmOe um r Woo' roe bm rrrnewuywrom Sm on rews roa roe wow nre.wsros Fire & Building tLJCI3 /Products Technical Services: Tel: (800) 381-9312/ Parr: (8001 791-5500 sOrew.tyco.tire.comrr Fncrron Fi05i51a00e (5yssg,919ffica)rymr SrraintPipet Size no- _PSL. ITceootr Run Feet Feet e F l Feet tcclmos me, MeterS Meters Meters Meters -TO- 1.9 - 53 42.4 13.6 0.3 1.5 0.6 TW 2.3 1,2 5.0 2,3 48.3 0.7 8.4 t.t n_i 2 32 1,6 0.0 3.2 60.3 1.0 05 2.5 1.6 2/r 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 02 4.1 2.1 10.3 41 7.2 0.6 e 10 1-9 133.0- 82 - - 4.9 88.9 1.5 0.7 3.7 1.5 - - 6.5 2.0 1.8 5.0 20 6.h T8 TH 114.3 2.0 1.0 5.0 20 2.4 1.2 0_1 24 8.0 3.1 20.0 0.0 139.7... 2.4 1,3 0.1 Z4 -0- TH25 041.3 2.5 1.3 6.3 2.5 - 95 2.9 1.4 7.2 29 TOl 3,0 t.5 7.630 66231 TO14.02810.0413 13.1 EST r -4.02.000 16,5 0.3 £0 2.5 12.6£0 199 49.7 19.9 cmeavtael0wMueuc.anenwOcoInCnnwenm4eg 6.1 3.0 05.1 6.0 Ftgome 201 Ftguem 210 Flgum 219 Figure 2602 reT aol Elbow 90 Elbow Ten End Ca e CL IT OM o.4 CrOk Apo. VA LteF hewn tr, CS lewE Inch s Lbs. lncfrns Lb'. borneO Lbs rnuhnu U. mm ,jpe,. mm KG. mm mm Ko. T-, 0.9 13G -3ty 3Y l.a 44.5 0.4 68.9 0.5 69.9 0.6 22,4 0.2 20, 0. - '135_ ,.n 13 - i- 13 W - 44.5 0.0 69.8 0.0 69_n 0.8 224 0.3 1No .o TE3S 3 TOY -bMA TH:ti 50.0 0.8 02.6 0.9 82.6 0.2 2 4 0.4 - 53 7579- 37 W 2 2-2 09 21/1' 57.2 1.0 95.3 7.4 95.3 2.6 224 0.4 - -Sc 3Jh TEg- W 6. elm 57.2 1.0 95.3 1.4 95.3 2.6 23.9 0.5 -peg- lS 31 TH.6W 13 63.5 0.0 100.0 2.0 108.0 32 224 0.5 - -T.79-- - 108.0mm 73.0 2.5 120.7 3,9 120.7 52 - - - 31 - 3.00 52 5.00 0.5 5.00 11.8 1.00 2.6 33.Qmmrm 02.6 3.5 133.4 5,1 133.4 4.0 - - 762 2.4 127.0 3.9 127.0 5.4 25.4 0.2 F.gurn 219 - 3 - pe -j- '1Stt 35 425 4S 2M 53 7.7 113 3.50 12-0 14.6 18.5 12.0 7.75 365 . b ES3 139. mm 92.6 3.5 039.7 5.1 135.7 6.9 23.4 21 - S 13 -pe --peg- 5.0 82.6 3.9 039.7 6.1 139.7 7.7 25.4 2.3 8.653 6,ee TOSt 1593mm 059 54 152,4 6,6 152.4 63 - - - '1TEg- 831 - TH31 - 165.1mm 05.9 54 165.1 8.4 165.1 01.8 25.4 3.4 231 631 08.9 5.4 165.1 5.4 065,1 11.8 20,4 3.4 0.25 23.0 3353 "ssg' 3553 2163mm 105.0 10.4 196.9 16.6 196.9 20.4 - - - 13pe 6- 753 pe 008.0 00,4 196.9 16.6 096.9 20,4 302 5.8 '53hpe 53St TE3553 651 TOStO' 35T 1353 20.0 10 020.7 14,0 228.6 27.2 229.6 32.7 30,0 9.t I .ummturu-.4 wron SS0' 00.0 10,00 921' 39hry 950' '131 36.0 033.4 18,f 254.0 30.4 254.0 42.0 31.8 06,3 Page 3O16 TFP1810 Figures 501, 510, 519.and 51 ODE CE ~01 Figures 501S, 510S and 519S Frgor0001S Flgcrebl057 fSgreo519S FigoreSOlS Figoee5l0SF/gore 5195 45 Elbow 982 bow The AWL i A 8600. Wsize 700909 Lbs.0805 LbS. 010705 lbS. elm /65 0110 - s:so 1.8 2.75 l.5 2.75 21 2 50.0 0.0 69.9 0.7 69.9 1 0•22 3.00 22 3.00 3.0 2 1 572 7.0 76.2 1.0 76.2 74 2-25 2.2 ® 5® 3.1 6....57.2 1.0 76.2 1.0 762 1.4 5® 5 555 s 41 63.5 1.6 85.9 1.3 85.9 7.9 . 440762 2.4 701,6 2.6 107.6 3.5 2.4 3.25 12482.6 3.5 124.0 3.9 124.0 5.4 -3.25 6.5 i5 84 4.88 12.002.6 3.9 124.0 3,9 124.0 5.43.50 120 5.50 11.00 5.50 15.0165.1..... 88.9 54 139.7 5.0 139.7 6.83.50 72.0 550 112 5.50 15288.9 5.4 739.7 5.1 139.7 6.9-425 230 6.80 6.08 31.20 0 74.8 10.6 774.0 74.2 27 5.8 F/g F.gom 910 F.gom 519 F/gem51506 45• 982 Elbow Tee 982 OWnElbowThC00ECWE EPP0.W.001E C 65Nem018nOse ethos LIII. Inches LbS. ethos 700760 loOsen Lb.. 1 44.5 0.4 69.9 0.5 69.9 0.6 - 11, 1.75 1.1 2.75 12 2.75 1.8 44.5 65 69.9 0.5 09.9 0.8 - 2.00 14 -s:s zs 155 50.8 0.8 82.6 0.9 820 12 55• -i-,s- s 5.6 'I75 2.09 :7r Er 2/c 57.2 7.0 95.3 1.4 95.3 2.6 85.3 50.8 69.9 12 -s:s- 3.7 63.5 1.6 708.0 20 108.0 32 708.0 59,4 69.9 1.7 365 5.08 ® s 55 7.0 762 24 1270 3.9 1220 £4 727.0 72.4 59.9 32 - 440 S5- s 76 s s 539 r 824 3.9 039.7 6.7 1357 7.7 139.7 85.9 69.9 £9 F 5 185 650 5505 98.9 5.4 165,7 8.4 155.1 17.8 165.7 98.6 69.9 6.7 55 825 -ss:s- s r 5,95 575 108.5 75.4 190.9 16.6 106.9 20.4 l 196.9 1257 599 17.9 Sloe 982 482 Bl0nh Ron Inches FeelFeet Fool Feet SY9:5 8.9 3260.3 1.0 0.8 2.5 7.05W3.0 2.0 9.8 3.973.8 1.2 0.6 3.0 72 761 4.1 2.0 10.3.112 0.6 3.1 1.2544122 t08,9 7.50,7 2.715 4 65 65174.3 2.0 1.0 5020 12578.04.1 20.0 8.-2.4 1.35.7 2.4 5 8.2 1 20.5821413 2.573 63 25659.5 29 7. 72 Z9 6 9.95.04 9968.3 3,0 1.5 Page 4016 rEFlow Figures 250 and 350 -EWE---' Fabricated F.9or4 350 Fabosoolod Si.cos 8270 12 Na,: 0000 ,n*ed..i050 eownt rl w, '04 05,050e n 400 850 050,. SeW .00050550 m0000 owney ,m150.weo.,o 050 eo00050ee. ADA CAP® Patented Pb ' [ll 76 30 66 328131 100 .10 Fg55,S0 550350 Concentric fl000cor.C.5r0000 0 Groeco - Norrunal ElI E .05p0. WI. Nominal €70 E Am, Wt Nominal E to 4.900. WL Sipo nOneS LbS. Sloe ethos l.bs. Sloe 1b Lbs. leehes mm _• feEbly met 105bps oem 65. 2.50 1.0 . 3.50 42 -6 4.00 5.6 2 oi/' p 0.5 139.7... 03 99 79 05 701.6 2.6 2.50 1.3 -139-7-.4 3.50 4.4 5.00 72.2 63.5 0.5 88.9 2.0 8.2 _?2Z.0 5.5 2.50 12 350 4.6 5.00 12.1 2402 63.5 03 5-8.9 2.1 802.4 127.0 55 2.50 1.5 3.50 4.6 5.90 12.0 76.1.,.el.4 63.5 5x2 88.9 2.7 803 1270 £5 250 1.6 • 3S0 4.5 5.770 17.9 02 635 08 502.4 88.9 20 804 _12 5.4 2.00 1.3 3.50 4.4 5.00 71.3 301 03.5 0.6 503 88.9 2.0 805 127.0 £1 1.3 - 3.50 45 5.00 10.0 30 1/. 63.5 0.6 504 88.9 2.0 606 727.0 4.9 - 1.3 • -5.00 5.5 - 6.00 21.9 F.gere 350 302 63.5 0.6 165.1.,.e _________ 3 101.6 2.5 1004 752.4 10.0 3.05 15 • 4.06 6.0 6.00 21.6 SioeS 82706 3025 75.2 0.7 165.1.., 54 101.6 27 1005 152.4 0.0 3.00 2.0 4.00 5.6 6. 21.1 3076.1.,... 762 701.6 25 1006 00 i!?:_ __.2__ 3.00 2.2 4.00 6.0 6.00 795 Inch 0.7 2-50 2-50 -B~ 401/. 762 1.0 - 602 101,6 2.7 1000 152.4 8-9 1.77-8 - 3.00 2.3 4.8/1 6.0 7.00 28.0 762 7.0 602/. 101.0 27 1204 1778 12.2 -4,2 3.00 2.3 - 4.00 6.0 7.00 30.0 762 6076.1..., 701.6 27 1206 7779 72.6 3.00 2.3 7.00 28.0 402/. 7&2 M 62 70 603 101.6 27 1208 __.1L!__ 3.00 32 4.00 5.9 7.00 33.0 4076.1... 76.2 1.5 -6 . 4 101.6 27 12010 177.8 15.0 3.00 2.6 '6 4.00 6.3 403 76.2 72 6' 135.7,.. 1014 2.9 Pi 0 NOe7ifls0l Olmeesi I Sloe O,gel WI ethOS ethos lethes 700*105 Inches 009 1.25 31.8 1.75 44.5 1.89 40.0 0.77 0.3 * 1.25 1.75 1.89 0.77 lo 1.900 48.3 31.8 44.5 48.0 0.3 1.37 2.00 2.02 0.88 344 504 51.3 0.4 1.25 31.8 1.75 44.5 1.89 48.0 0.92 0.4 / 125 31.8 1.75 43.5 1.89 48.0 0.92 0.4 2 2.375 50.3 1.37 2.00 2.02 1.06 34.8 50.8 51.3 0.5 1.47 37.3 1.97 50.0 1.89 48.0 129 0.6 2/. o ' 2.675 73.o 7.4.7 37.3 1.07 50.0 1.89 48,0 128 0.6 355 2.00 2.02 7.50 1 34.0 504 51.3 0.7 Page 5036 5FP1810 Figures 391, 392, 393, 312 and 313 Figure LU I Figure 392 h EeE 393 fiLli Figure Figure 312 niE 313 Fgura Fig ren3 JIIP Ore 6 Appn. Wt Cr06 Apprl. WI. Cr0 F ApprI. WI. nOtes 1010 Lbs. Inches Lbs. Inches Lbs. - 1 4.00 0.0 1.75 0.4 1.38 0.4 103,6 0,4 44.5 9.2 35.1 02 500 0.9 1.75 05 1.38 0.5 301.6 0.4 46.5 0.2 35.1 0.2 2- 4.00 12 1.88 0.6 1.30 0.6 1016 0.5 47.8 0.3 35,1 0.3 2 4.00 1.9 2.00 0.7 1.50 3.1 301.6 0.9 50.8 02 351 0.5 - 4.00 2.5 2,25 1.4 1.50 12 101.6 3.1 572 1 0.6 38.1 0.5 '4 • 6.00 5.5 2.63 2.4 1.75 2.2 152.4 2.5 66.8 - l.11 44.5 1.0 6.00 7.4 2.88 4.7 2.00 3.3 102.4 3.4 732 3.9 50.8 1.5 6.00 9.5 3.13 5.6 2.00 4.6 1524 4.3 79.5 2.5 50.8 2.3 - 6.00 142 3.88 11.1 2.00 8.7 152.4 6.4 98.6 5.0 50.8 3.9 10- 8.00 27.0 4.38 14.0 2.13 9.1 203.2 122 113 6.4 58,1 4,1 12. 8.00 2 33.0 4.80 22.0 2.25 16.7 203 15.0 124.0 0.0 1 572 7,6 Figures 327 and 341 Figure 327 H6 ELr Figure 341 page 6or6 TFP18I0 Figure 321 L_. ctnnerul Notes. It is 160 OnsignoOs rncponcb4ity l850lentproducts suitable for the islended servrce 00878 nrrsarc ISO 1001 pressure 1030195 and perlarorarrco 40lr rs nor eroeedcd. Aticnss rnadarrd undn.51nd 780057800580 u0sttuct'oflS 9001 (74.1000). None.' mmccc any piping componer.. or correct or nrorilry any piping deficiencies withour first dnpnl550mining and dralrring the sysrcnm. klarccol and 9401101501e51i0n should Sc unrifled to he cennpalibln for me specific application. Cer'tihed Comnpany TYCO FIRE PRODUCTS. 451 harm Cuenoc Acecce Lanedale. Panssylaanic 19946 Plinled U.S.A. Flgorn 323 R,nt ocic9 TnO Noo,ie0l Cr06 ApprI. WI. Neosnal CtoE Appn.WI. Sloe mOtes Lbs. Sioo Inchec Lbs. Itches reel IcuSte 10771 415. iou oti vi 3.25 2.0 6 6 4 ° ° 6.50 26.0 82.6 0.8 165.1 12.2 2 2 iT' 3.25 2_7 0 6 6 5 6.50 27.0 - 82.6 1.2 1657 122 Figure 321 2'hc2lsoi'/r 39 80802 7-75 36-2 2½n2½01½ 8n8n3 2½ 2½ 2 8 8 4 7.75 36.6 95.3 20 396.9 16.6 0 154 8n 36.8 708.0 24 16.7 3.3x2 '4' 60 5 8 6 37.0 108.0 25 196.9 16.8 3 3 2,4 '425 10 10 2 9.00 57.1 708.0 26 228.6 25.9 O 01 5.00 9.8 On x 930) 57.4 228.6 26.0 4 5.00 9.9 00 ' 9.00 07.6 127.0 4.5 228.6 26.1 10.1 0 ° 9.00 07.8 2270 4.6 228.6 262 o 5.00 10.3 1 6 ° 9.00 56.0 1278 4.7 2286 263 03 0 8 On ° 9.00 58.4 1270 4.8 228.6 26.5 5c502 5.50 14.5 12,11203 10.00 80.2 139.7 6.6 254.0 36.4 5n552½ 530 14.8 12n1204 10.00 80.5 730,7 6.7 254.0 363 505u3 5,50 15.2 13c1255 10.00 80.7 339.7 6.9 254.0 36.6 Oct04 5.50 15.8 1201256 10.00 80.9 139.7 7.2 ___________ 204.0 36.7 61602 650 26.5 1201208 10.00 91.4 160.1 13.9 2.54.0 475 ____ 6c602½ 6.50 26.5 12c12010 10.00 91.8 065.1 12.0 2.56.0 47.6 60603 6.50 26.5 165.1 12.0 Fig. 200 "Trimline" Adjustable Band Hanger Size Range - 1/2' thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 ... specifications Function For fire sprinkler and other general piping purposes Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (27,-" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL.) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SF-69, Type 10. Maximum Temperature - 650"F Finish - Mu, Galvanized, For Stainless Steel materi- als, order TOLCOTM Fig. 200VVON, Order By - Figure number and pipe size Dimensions Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs, Length 1/2 3/8 8mm or 10mm 3/8 22/e 400 11 3/4 3/8 8mm or 10mm 3 1/8 2V7.400 11 1 3/8 8mm or 10mm 32/s 2/e 400 12 11 /4 3/3 8mm or 1 Om rn 34 2 '/a 400 13 11/2 3/8 8mm or 10mm Ps 2/ 400 14 2 3/8 8mm or 10mm 4/2 3 400 15 21f 3/8 10mm 5/e 4'/e 600 27 3 3/8 10mm 5 /8 4 600 29 31/2 3/8 10mm 7?/ 5/.1 600 34 4 3/8 10mm 73/3 5 ioo 35 5 1/2 12mm 91/ 6/4 1250 66 6 1/2 12mm 101/ 6'/, 1250 73 8 1/2 12mm 13'/ 33/4 1250 136 Mair, Oftice/Ma'ruFeclnrin Facility ).!Pl Ak" • /:,r,3 :Ii r•2Ir,.i'l, 09 r/ ym/ • In,: dO ri Customer Service • '.'O www, to/co. acm Dimensions 'Weights Rod Max, Rec, Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 '1010 5/8 1810 '1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range Secures 3/8 thru 7/8 hanger rod Material -- Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. ' Finish , Electro Galvanized Note -- Available in HDG finish or Stainless Steel materials, Order By - Figure number Fig. 99 All Thread Rod Cut to Length 0S 3/8" thru 7/8' rod in nc ts Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note . Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10 lengths Material - Carbon Steel Maximum Temperature - 750F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec, Load Lbs. Rod For Service Temps Approx, Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 '1130 _Jii... 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 8000 7140 360 1/2 11630 10370 510 Main O If! ce/Ma,iulaclurinq Facilily . 13/f, i;nj A,''Lc,'ic2, (:i 1 5)9 /3/ )!5) 909 1315)39.' 13 C,,slviner Service 9(1) 199 wwwtolcv,cvrn cus LISTED UL Listed Design Load Sch, 7 1600 lbs. (7,11kN) Sch. 10 & 40w/1" (25mm) Brace Pipe 2015 lbs. (8.96kN) Sch. 10 & 40 w/11/4' (32mm) Brace Pipe - -- 2765 lbs. (12.30k) S,ze (unni)'16 Lb :Pirt:Ntimbet &• pro!c.WL!100; •'. ::. ,: 1" (24mm) Brace Pipe 11l4 (32nim) Brace Pipe (kg) Lbs (kg) esi!Jn:, Load See load ratings in UL Listed Design Load chart. The loads listed are axial loads on the brace, The horizontal load capacity, H, of the brace is; H = F x sin ?, where ? is the installation angle measured from the vertical, Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 21/2 (65mm) thru 8' (200mm) IFS, Pipe size used for bracing: 1' (25mm) and 11/4" (32mm) Schedule 40 IFS. Material: Steel Function: For bracing pipe against sway and seismic disturbance, The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IFS, Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" (25mm) pipe extension is recommended, Brace pipe can be installed on top or bottom of pipe to be braced, Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 65, Finish: Plain, Contact Cooper B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" (25mm) or 11/4" (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other Cooper B-Line/TOLCO bracing products. All dimensions in charts and on drawings are in Inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. - .. COOPER B-Line C& us LISTED Set Bolt Included Mounting Hardware Is Not Included Fig. 980 - Universal Swivel Sway Brace Attachment - 3/9" to 3/4" Size Range: One size fits bracing pipe 1(25mm) thru 2" (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4 (31 .7mm) thick Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle, Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the bracing pipe and Cooper B-Line/TOLCO 'braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed, To Install: Place the Fig. 980 onto the 'bracing pipe', Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 61. Note: Fig. 980 Swivel Attachment and Fig. 1001, 1000, 2002, 4A or approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish, Pat, #6,273,372, Pat. #6,517,030, Pat, 46,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Fig. 980 Fig. 4L <: Longitudinal Brace ai toad .I.1ax.Dcsign.:" jcULus):::. *1109 ::' in (mm) ', in Qnni i up fin, in Qwu ' in Onm lbs k) Standard size. Cooper B-Line, Inc.'s ('Cooper B-Line") seismic bracing components are designed to be compatible only with other Coop e r B - L i n e bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing compone n t s w i l l b e the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in - •. addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line' s s e i s m i c bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. ' COOPER B-Line Hllb5 ana F1SX NUtS incivaeo Fig. 4A - Pipe Clamp for Sway Bracing Size Range: 4" (100mm) thru 8" (200mm) pipe. For sizes smaller than 4" (1 00mm) use B3140. Material: Steel ifs) ' •1 c®us LISTED Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 4' (100mm) thru 8" (200mm). Installation Instructions: Fig. 4A is the 'braced pipe attachment component of a longitudinal, lateral or riser brace assembly. It is intended to be combined with the 'bracing pipe' and Cooper B-Line/TOLCO transitional and structural attachment component(s) to form a complete bracing assembly. NFFA 13 guidelines should be followed. To Install: Place the Fig. 4A over the pipe to be braced. Attach Cooper B-Line/TOLCO transitional fitting, either Fig. 980, 910, 909, or any other Cooper B-LineffOLCO approved transitional fitting. Tighten bolts and nuts; torque requirement is a minimum of 50 ft/lbs. (68Nm). Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish: Plain, Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish Note: Please refer to Fig. 4L for longitudinal brace applications for 2" (50mm) 8" (200mm) pipe sizes. Fig. 4A Longitudinal Brace Part Pipe size A ir B C 9 Soft (Wax Horizoiital Desjjn Load Approx WI (100 No In (mm) Ifl (111111) In (mmmlii) Ii j, (mnni) in (mimi) Size lips (kN) lbs (kg) Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper 6-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line, All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 825A Bar Joist Sway Brace Attachment C®US LISTED Size Range - One size accommodates all TOLCO Fig, 900 Series sway brace attachments. Maximum Horizontal Design Load 1265 lbs. 3/8" Material - Carbon Steel Function To attach sway bracing to steel open web structural mem- bers. Features - This product's design incorporates a concentric attachment point which is critical to the performance of structural seismic connec- tions. NFPA 13 indicates the importance of concentric loading of con- nections and fasteners. Permits secure non-friction connection without drilling or welding. Unique design reinforces point of connection to joist. Break off head bolt design assures verification of proper installation. Approvals - Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions - The Fig. 825A is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe" and a TOLCO "braced pipe" attachment to form a complete bracing assembly NFPA 13 and/or OSHPD guidelines should be followed. Maximum Design Load 1265 Lbs. To Install - Place the Fig. 825A on the steel beam, tighten the cone point Bar joist shown at ached -to various roof materials set bolts until bolt heads break off. \ Max . Attach other TOLCO transitional attach- . . . X. \ j/ ment fitting, Fig 909, 910 980 or 986 Transitional fitting attachment can pivot 1 for adjustment to proper brace angle 4 / Important Structural Note: //)K The TOLCO Fig. 825A has significant UL established design loads, however, '..... Shown with Fig. 980 structural issues related to the steel -.. - joist member require restricted location installation for all bracing. Steel Joist .... \.:::::../,4..L:...:.:....:..._ ....... .... Manufacturers require that all earth- / quake bracing connections be within (V /..., . May pivot in 6 of the cord panel point. Installation any direction of the Fig. 825A is not restricted to the two outer third sections of the joist. For greater design loads, refer to TOLCO Fig, 825. Finish - Plain Order By - Figure number and finish Patent #6,098,942 TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLcO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. • CORONA, CA 92879 9 PH: 951,737.5599° FAX: 951.737.0330 CUSTOMER SERVICE' 800.786.5266 In www.tolco.com IY6 APPROVED LISTED 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVO 1-1/2 300 1.5 8008957 GST 20 X 2-1/2 850 1.5 8068925 GST 20 SS X 2-1/2 850 1,5 8010957 GST 30 X 4 1500 1.5 8009925 GST 25-380 X 4 1500 1.5 8022925 SWG 25-380 X 3-1/2 - 4 1500 1.5 8021957 SWG 20 X 2-1/2 3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SH GST 2O X 3 1050 1.5 8141957 SH GST 3O X 4 1500 1,5 8140957 SH GST 20 SS X 3 1050 1.5 8142957 SH GST 3OSS X 4 1500 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 8038957 DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEKSO X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0,0600 8054957 SWDR 1-1/2 X 4 1500 0,037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 8059957 CST 20 X 4 1475 3000 PSI 8061957 SWC2O X 4 1475 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2 SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4' ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2' ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" UL and FM tests were performed in compliance with NFPA-13 Standards, Fastening requirement 5 times weight of water filled schedule 40 pipe plus 250 pounds JA it LwBuiIdex wwwitwbuildex .com 800-284-5339 S5S26 ON.( OQII:~ NO MODEL 1000 1!3 3/4" 1" 11/4" 11/2" 2" 0 The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System The Model 1000 Complies With All Requirements Of NFPA-13. NFPA-13R. And NFPA-13D. 0 The Model 1000 TESTANDRAIN Is A Single Handle Ball Valve That Is Light Weight And Compact, Includes A Tamper Resistant Test Orifice. Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. O Available In A Full Range Of Sizes From 3/4 To 2 NPT & BSPT, With All Specifiable Orifice Sizes 3/f. /ió", Vs'. 17/if, 5/s" (ELO), 3/4' (ESFR) and K25. O The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. The Standard Model 1000 TESTANDRAIN Valve Includes A Pressure Gauge Port Tapping And Can Be Ordered With A Relief Valve As A Model 1011 Or 1011 T O Locking Kit Avoiloble Which Provides Superiol Vu, ,dul Resislu,,ee And Prevents Unintentional Alarm Activation. oc- -ç' on the V,sit Inte us rnet (01 MODEL 1000 300 PSI (~o <S> r 3Y MDRMN 3/4 1 11/4 11/2' 2 iN.IiJCCN 30014 BIICNCB GAUGE *11.51 /30001050 15 STREET EL JIVI To ST.EET E, oR PiPE TO DRAiN 5iG.T ND1sTt.xG1.T 1.NSTALLATON APP2O'.i.S: ULand ULC Listed 0 FM Approved except 3/ ORIFICE SIZE i_ NYC-BSA NO. 720-87-SM AVAILABLE - 318-. 17/167. 1/2'. 17/f, ao(s/a'). ESER(3/4T and I(.25 'AooIIot,Io on 1/2' 102' lIfe UnIT only. u CA. State Fire Marshall DIMENSIONS - INCHES SIZE A B _ci 0 E G H i" S ",C I 'If 2 'i" 3 lye 3 3/f 1 ',C 4 i,C 6 3C 451Un,, TS49,. - T440 I 103"-' 4S.30fl 1" 5 'FtC 1 'if 2',o" 351( J 3f fi ' 4W,C . 6'C I2AU 4131, fl2Un a500,. 4&UG4 llj300, Iota,,,, HANDLE 515(1. 1I45" 1"f 2 'IlC4'1f;3 51ICI1'5/lCS9/Ifi5 '/f M ROD BRASS - BALL CF. BRONZE BOOS BRONZE 1 f 6 7fC ] 131,f 3 1: 5 11,C 3 3,f 2 'o' 8 'I' 107/811 SIGHT GLASS II.N' i VALVE SEAT IMPREGNATED TEFLON 2" ' HANDLE LOCK SPRING STEEL "3/e Voice UI. Wed only. AGF Mn.ofoctonng Inc JOB NAME <101 40-0900 0- (6 4) 40-4930 :':. ARCHITECT ::- ENGINEER: CONTRACTOR: 3/tIE CAUTION: An uninsulated sectiun of a single conductor should not be looped around the termi- nal and sewn as two sopa- role connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal uref soc nail si/C tuna., mc tvect toil nanet ttct' a' cr10' 205ev) sO,,,,,, covet Cocos Tonpor (nun- owes in plecel ffl nec. lust-ca 1 p0-ITER - - - The Symbol of Protection ULULCandCSFMLi000d,FtaandLpCliAppcoved,NYMEA Accepted, CE Marked Service Preounsce: Up to 450 PSI (31 BAR) Minimon, ftusvR.ateforAlarm: 1O GPM (38 1PM) Maximum Surge: 18 FF5 (5,5 m/s) ContactRotings Two sets of SPOT (Form C) 15.0 Amps at 125i250VAC 0 2.0 Amps at 3OVOC Resistive - Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: Suitable br i0000r or outdoor use with factory instated gasket and die-cast housing. . - NEMA 4itP54 Rated Enclosure - use with appropriate conduit lilting. - Temperature Range: 401/120"F, 4,5"C140"C - Non-corrosive sleeve factory instated in saddle. Caution: This device isnot intended for applications to explosive I eevlroen,aetS. -. Sizes Available: Steel Pipe schedules lottnts, 40. sizes 2'thru8 ES 1307 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR.CF. Service Use: Automatic Sprinkler NFPA'13 U.S. Pat No. 3921909 One ortwofanlitydvreoing NFPA-130 Canadian Pat. No. 1009680 Residential occupancy up to four stories NFPA-1 3R Other Patents Pending National Fire Alarm Code NFPA.72 Potter Electric. Rd.. 1990 Optional: Cover Tamper Switch Kit. Stock No. 0090018 - GENERAL INFORMATION The Model VSR-F is a vane type walerllow, switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe: schedules 10 through 40. sizes 2" thru & (50mm thIn 200mm). LPC approved sizes are 2" thou 0" (50mm thru 20001111). The 0011 may also be used as o sectional waterltaw detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic re-turd. The switches are actuated when a 110w of 10 gallons per minute (38 1PM) or more occurs downstream of the device. The 80w condition most exist for a period of time necessary to overcome the selected retard period. ENCLOSURE-- The unit is enclosed in a general purpose, die-east housing. The cover is held in place with two tamper resis-tant so-ones which require a special key for removal. A field in-stallable cover tamper switch is available as on option wttids maybe used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions 01 this switch. Poner Electric Squat Company " 2001 Craig 50011 SI, bum. MO. 63146.4161" Phone: 000.325-3936/Cnoada uon-802-1u33- Wrnv.ponwnignal.cem pwrrrcn IN MtC.00nouai)I .REVW PAGE 1 0F2 MFG.115400761 .7102 swnncc. POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD FIG.1 FIG.2 SWITCH TERMINAL CONNECTIONS oerons. tumet vcocn 00 nOt Lcust Coven Ott tOO CLAMPING PLATE urrccofn ecwno or ruE TERMINAL Ou cml lcnnm uercnmu) ncatyu rats Ic ROLL Pnntt.c opposes ono-now o- eumERe.on atenoc octsoO Scribes to. sep51 FiG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: FIG. 4 1. The Model VSR-F has ton To remove knockouts: Place owituhnn. 0110 0 he used to screwdriver at edge of knock' operate a central station, pro. priatmy or remote signaling outs, not in the center. visual annunciator. thie product is that the electri- cad entry nivat be .—Id to -i-d circuits dneg and caution m10 (Fig. 1). APPUCATION WARPOINGI Due to the possibility of unintended discharges caused by pressure sorges. trapped air. or Short retard times. matettlom switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF. deluge, or chemical suppression systems. TESTING The frequency of inspection 000 testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable POPPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve. that is usually located at the end of the most remote branch bee. Should always be used 11cr test purposes. If there am no provisions for testing the operation of the tore detection device on the system, application of the VSR-F is not recommended or advisable. A minimum Item of 10 gpnt (38 1pm) is required to adivate this device. IMPORTANT NOTICE-- Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Pnttarco In usa .)Cr. 000000ot - REVW PAGE 20F 2 MrG. n5a007cr -7/02 VS R-Z7 VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD INSTALLATION: See Fig-2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed On the top side of the pipe where they will be accessible. The units should not be in' stalled within 0" (15ct0) of a lilting which changes the direction 01 the waterfiow or within 24" (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slum spend drill The 2" (50mm) and 2 112" (65mm) devices require a hole with a diameter of I 1/4" 1/0" - 1/18" (33mm z2snen). At other sizes require a halo with a diameter of 2 ±118" (50mm *2cein1). Clean the inside pipe of all growth or other material for a dis-tance equal In the pipe diameter on either side of the hole. Rug the vane so 11101 it may be inserted into the hole: do not bend or crease 6. Insert the vane so that the arrow on the saddle points in the direction 01 the watertlom. Install the saddle strap and tighten nuts alternately to an eventual 50 8-lbs. (68 n-en) of torque (see Pig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice Noles: - - - Minimum d8 ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 1500F (-34° to 660C). Typical d8 ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 0000TS 0* 000.51000 010001000. 60000010. C0000000 OTTO Pt 000(14 AT lOPE 001110 00200) 1O'OOC P00010 011000 .00* 00 = 0000) 0010* 000210 (00020 000 01 10 10050) *21/DC P000*00 110080 000 00 00 *0)00) 0002* 70,0200 0000020 .17* 01 70 0(210) 2.0*0 70029 1000100 .07* 00 71 0140) 3000* 70*3000 001000 - .010 0* 70 0(1w 1*51*2* P0*1*10 010)10 060 02 - - 02 0(200) 1201*0* 7001100 1010120 .065 00 02 10)000) 0*50*0* 70*0001) 1010110 .050 05 05 6°° BELL SHOWN POTTER PBAAC&PBI) DC The Symbol of Protection UL Listed Saes Available: 6(150mm), 80 (200mm) and 10(250mm) Voltages Available: 24VAC 12OVAC 12VDC (102 to 15.6) Polarized 24VDC (20.410312) Polarized Service Use: Fire Alarm General Signaling BurglarAlarrs Environment lndoororoutdooruse (See Note)) -.40 to 1500F (-40 to 66C) (Outdooruserequiresweatherproof backbox-) Termination: 4 No. 18 AWG stranded wires Finish: Red powdercoating Optional: Model 88K-I wealheoproofbackbox These vibrating type bells are designed for use as lire burglar or general signaling devices. They have tow power con-sumption and high decibel ratings. The unit mounts on a standard 4 (101 mm) square electrical box for indoor use or on a model 88K-I weatherproof backbox for outdoor applications. Weatherproof backbox model 80K-1. Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Pooertlen6)o Sgnu) Cp*ny -2081 Coxog Road. 5 Loon. 000.63506-0161 - Phone: 800-325-3936JCanisfa888-882-1833' wo00pogeroign.0t.caTT 08(00*0 oN usA MId 08050081-Revs PAGE) OF 2 0*rc.05400776.5,05 ) POTTER PBA-AC&PBD DC The Symbol of Protection DIMENSIONS INCHES (mm) FIG. 1 BELLS FIG. 2 WEATHERPROOFBACKBOX SOXHPSONETHIREADEO 1l2CON0UrrENTRANCE Ir V"r, L~L 2 iT/O ow. ano till FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLfitfihlY) A.C. BELLS 0.0 01, 09052J 000 0100 0-00 (0*1) CZ(F. meow 000109 005*00* P01,0ev (0 0000 O.C. 00.25. 0. 000000 0500* 0.0, 00.05. rg.°TOATE £0000 (1*100 (logE 5000000*17 0*0 'lOSES P0900* (.) OtTER LOST 0*0, 0*005 0015CR 0*800055 (-1 2. DoD-SE-usc 0<50008 6 nor sEcuREs a. AC. Sans. 00(0. 9775-3 INSTALLATION I. The bell shall be installed in accordance with NFPA 72 Or local Ahj. The lop of the device shall be no less than 80° Aft and not less than 6° below the ceiling. Removethegong. Connect miring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). P0000*0010 USA 121Cr. 0085000,-REVS PAGE 200* 12*6. 05000776 . 5005 (I ES-A-3000SS Series 3000SS A A M E S Double Check Detector Assemblies FIRE & WATERWORKS Sizes: 21/211 - 12" (65 - 300mm) Series 3000SS Double Check Detector Assemblies are designed for use in accordance with water utility non-health hazard containment requirements. It is mandatory to prevent the reverseflowof fire protection system substances, i.e., glycerinwetting agents, stag nantwater and water of non-potable quality from being pumped or siphoned into the potable water supply. Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a drinking water supply. Degree of hazard present is determined by the local authority having jurisdiction. The main valve body shall be manufactured from 300 Series stainless steel to provide corrosion resistance, 100% lead free* through the waterway. The double check detector assembly consists of two independently operat- ing, spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass assembly. The bypass assembly consists of a meter (cubic ft. or gallons), a double check including shutoff valves and required test cocks. Each cam-check shall be internally loaded and provide a positive drip tight closure against reverse flow. Cam-check includes a stainless steel cam arm and spring, rubber faced disc and a replaceable seat. There shall be no brass or bronze parts used within the cam-check valve assembly. The check valve seats shall be of molded thermoplastic construction. The use of seat screws as a retention method is prohibited. All internal parts shall be accessible through a single cover on the valve assembly. The valve cover shall be held in place through the use of a single grooved style two-bolt coupling. The bypass line shall be hydraulically sized to accurately measure low flow. The bypass line shall con- sist of a meter, a small diameter double check assembly with test cocks and isolation valves. The bypass line double check valve shall have two independently operating modular poppet check valves, and top mounted test cocks. The assembly shall be an Ames 3000SS. Materials All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless steel, Check assembly: Norylm Flange dimension in accordance with AWWA Class D. Noryl® is a registered trademark of General Electric Company. IEl It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes. Contractor Approval Contractor's P.O. No. Representative__._ Features Cam-Check Assembly valve provides low head loss Short lay length is ideally suited for ret- rofit installations Stainless Steel body is half the weight of competitive designs reducing installa- tion and shipping cost Stainless steel construction provides long term corrosion protection and maximum strength Single top access cover with two-bolt grooved style coupling for ease of main- tenance No special tools required for servicing Compact construction allows for smaller vaults and enclosures Furnished with /e" x 3/4" bronze meter (gpm or cfm) Detects underground leaks and unauthorized water use Maybe installed horizontal or vertical "flow up" position Available Models Suffix: LG - less shutoff valves OSY - UIJFM outside stem and yoke resil- ient seated gate valves OSY FxG -flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection CFM - cubic feet per minute GPM - gallons per minute meter Post indicator plate and operating nut available - consult factory *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Job Name_ Job Location Engineer - Approval - Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. amesfirewater.com A I .4 , Pressure - Temperature Temperature Range: 330F - 110017 (0.5°C - 43°C) Maximum Working Pressure: 175ps1 (12 bar) Capacity Flow curvesastested by Underwriters LaboratoryperUL 1469,1996. * Rated flow **UL Tested 'II:LIEItI4 iF .__-------Ui ..• .: .R I_l • • a _______. iu i• kPa psi 4" (100mm) 103 15 - 62 9 83 12 41 6 - - 0 0 -- 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 gpm 171 380 570 760 950 1140 1330 1520 1170 1900 2090 2280 2470 26602850 1pm 5 10 15 fps 1.5 3 4.6 mps I C [Open) op Standards ASSE 1048, AWWA C510-92, CSA B64.5, UL 1469 Approvals UL Classified (OSY only), FM (sizes 21/2 - 10, OSY only) 9SIP/. Approved IIiiuI411Ti1Tfl Lw ••• u• i.i I ...... i . I I ___. 00100 1 1 0. IIi...I i•i i•••i ._. I i•••••i . I • _. I ______.__I ._. I iI-------- ;it 11 SIZE (ON)I'Jl0ltk11I]i8 NET WEIGHT NET WEIGHT in. mm in, A mm in. C (OSY) mm D in. mm G in. mm L in. mm P in. mm wlGates lb. kg. w/o Gates lb. kg. 2'/2 65 37 965 16/8 416 31/2 89 10 250 22 559 121/2 318 155 70 68 31 3 80 38 965 18/8 479 33/4 95 10 250 22 559 13 330 230 104 70 32 4 100 40 1016 22/4 578 41/2 114 10 250 22 559 141/2 368 240 109 1 73 33 6 150 481/2 1232 301/8 765 1 51/2 140 15 381 271/2 699 151/2 394 390 1-77-7-120 54 8 200 521/2 1334 373/4 959 6/4 171 15 381 291/2 749 181/2 464 572 259 1 180 82 10 250 551/2 1410 1 453/4 1162 8 200 15 381 1 291/2 749 19'/2 495 774 351 1 190 86- 12 300 571/2 1461 1 531/8 1349 91/2 241 15 381 1 291/2 749 21 533 1 1044 474 1 220 100- A _ AM ES I19OO1-2OO8 FIRE&WATERWORKS amesfirewater.com - iRTIFIED A Watts Water Technologies Company USA: Backflow- Tel: (916) 928-0123 • Fax: (916) 928-9333 Control Valves- Tel: (713) 943-0688 • Fax: (713) 944-9445 - Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 Latin America: Tel: (52) 81-1001-8600 ES-A-3000SS 1410 0 2014 Ames Fire & Waterworks Remote Area i'r', I Demand I iunn - clv I Graph 250 200 50 0 0 250 145.68 psi available at Sprinkler Demand of 143.73 psi with System Flow of 1,443.1 GPM - —L Margin N185 500 750 1000 1250 1500 Water Flow (GPM) 1750 'S 88OO Dashboard Hydraulics Hydraulics Summary Sheet Project Information Calculation Date: 5/2312016 9:43:34 AM rSR CARLSBAD OAKS BUILDING B system ID drawing ref WHIPTAIL LOOP CARLSBAD, CA contract # ra.fra-fnr Tnfalrn,4i,%n EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 calculated by ADAM BOISVERT telephone 760-310-6122 fax 760-798-0556 email EPICFIRE@COX.NET i— Sprinklers in Remote No. Mfgr Mod SIN# Size K 12 1 VIKING I ESFR I VK500 1 3/4' 114.0 building NEW construction CONC/WOOD occupancy WHSE authority Hydraulics Criteria - system type WET density ESFR GPM/ft'design std NFPA 13 remote area 12 HEADS ft' hazard EXTRA spr coverage 50 PSI ft' sprs flowing 12 figure calc'd volume 10,803.6 gal curve CI,,w The4 static pressure 146.70 psi residual pressure 122.40 psi quantity flowing 8,000.0 GPM elevation from if 0.00 ft date & time of flow test 2-18-16 location of flow test SITE 0 Copyright 2013 Sigma Development Group, Inc. Page 1 of 9 6 41`478 8 oo Dashboard Hydraulics Supply Analysis SR CARLSBAD OAKS BUILDING B (Remote Area 1) Sprinkler Flow: 1,193.1 GPM Additional Flows: 250.0 GPM Hose Flow at Zero: None Total System Flow: 1443.1 GPM Maximum velocity in pipe 27-47 is 17.1 ft/sec Nodes Analysis Minimum Node Actual Node Elev Device KFactor Flow Pressure Discharge Notes ft GPM psi GPM 109 37.1 Sprinkler 14.00 99.00 50.01 99.00 110 37.1 Sprinkler 14.00 99.00 50.01 99.00 105 37.1 Sprinkler 14.00 99.00 50.05 99.05 106 37.1 Sprinkler 14.00 99.00 50.06 99.05 101 37.1 Sprinkler 14.00 99.00 50.23 99.22 102 37.1 Sprinkler 14.00 99.00 50.23 99.23 108 37.1 Sprinkler 14.00 99.00 50.63 99.62 104 37.1 Sprinkler 14.00 99.00 50.68 99.67 111 37.1 Sprinkler 14.00 99.00 50.74 99.72 107 37.1 Sprinkler 14.00 99.00 50.79 99.77 100 37.1 Sprinkler 14.00 99.00 50.86 99.84 1 103 37.1 Sprinkler 14.00 99.00 50.97 99.95 3 9.2 Hose Flow 137.38 250.0 © Copyright 2013 Sigma Development Group, Inc. Page 2 of 9 089'r Dashboard Hydraulics O' Pipe Information SR CARLSBAD OAKS BUILDING B (Remote Area 1) From Elevl ft Pipe ID Flows Added T I Inside Length I E C Value I Total (Pt) PSI1 I I Fitting ft I I Elev (Pe) psi GPM I Diameter Fittings I Notes To Elev2 Type I in Friction Lossi I I I ft Total ITotal ft[ psi/ft IFdct( psil 110 37.07 2' Dyna Flow 2.2030 Len 10.0 Ftg 0.0 c = 120 0.00015 Pt 109) 50.006 Pe 0.000 Pt 0.002 109 37.07 BL 4.1 Total 10.0 111 37.07 2" Dyna Flow 99.0 2.2030 Len 10.0 Ftg 0.0 C = 120 Pt 110) 50.008 Pe 0.000 Pt 0.729 110 37.07 BL 103.1 0.07285 Total 10.0 49 37.07 2" Dyna Flow 99,7 2.2030 1 Len 129.3 Ftg 13.6 c = 120 Pt 111) 50.736 Pe 0.000 Pt 36.408 111 37.07 BL 202.8 0.25480 Total 142-9 1 29 36.24 2" Dyna Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 0.25480 Pt 49) 87.144 Pe 0.359 Pt 3.687 49 37.07 RN 202.8 Total 14.5 28 36.24 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 0=120 Pt 29) 91.191 Pe 0.000 Pt 0.097 29 36.24 CM2 202.8 0.00970 Total 10.0 Total Pressure at Node 28) 91.288 psi 108 37.07 2" Dyna Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 Pt 109) 50.006 Pe 0.000 pf 0.626 109 37.07 BL 94.9 0.06258 Total 10.0 39 37.07 2" Dyna Flow 99.6 2.2030 T,8EE Len 218.3 Ftg 35.5 C = 120 Pt 108) 50.632 Pe 0.000 Pt 59.873 108 37.07 BL 194.6 0.23599 Total 253-7 1 19 36.24 2" Dyne Flow 2.2030 T Len 0.8 Ftg 13.6 0=120 Pt 39) 110.505 Pe 0.359 Pt 3.414 39 37.07 RN 194.6 0.23599 Total 14.5 18 36.24 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 c = 120 Pt 19) 114.279 Pe 0.000 Pt 0.090 19 36.24 CM1 194.6 0.00898 Total 10.0 Total Pressure at Node 18) 114.369 psi 106 37.07 2" Dyna Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 Pt 105) 50.055 Pe 0.000 Pt 0.002 105 37.07 BL 4.1 0.00019 Total 10.0 107 37.07 2" Dyne Flow 99.1 2.2030 Len 10.0 Ftg 0.0 C= 120 Pt 106) 50.057 Pe 0.000 Pf 0.730 106 37.07 BL 103.1 0.07296 Total 10.0 0 Copyright 2013 Sigma Development Group, Inc. Page 3 of 9 U88 a' Pipe Information AMR SR CARLSBAD OAKS BUILDING B (Remote Area 1) From Elevl Pipe ID Flows Inside I ILength ft I c Value [Total (Pt) PSI1' ft Added GPM Diameter Fittings I I I Notes I Fitting ft Elev (Pe) psi To ft Elev2 Type in I Friction Lossj Total ITotal ft[ psi/ft 1ict( psi 48 37.07 2" Dyna Flow 99.8 2.2030 1 Len 129.3 Ftg 13,6 c = 120 0.25510 Pt 107) 50.786 Pe 0.000 Pt 36.451 107 37.07 BL 202.9 Total 142.9 28 36.24 2" Dyna Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 Pt 48) 87.237 Pe 0.359 Pt 3.691 48 37.07 RN 202.9 0.25510 Total 14.5 27 36.24 4" Dyna Flow 202.8 4.3100 0 Len 10.0 Ftg 0.0 C= 120 0.03499 Pt 28) 91.288 Pe 0.000 Pt 0.350 28 36.24 CM2 405.7 Total 10.0 Total Pressure at Node 27) 91.638 psi 104 37.07 2" Dyna Flow 2.2030 Len 10.0 Ftg 0.0 C= 120 Pt 105) 50.055 Pe 0.000 Pt 0.626 105 37.07 BL 95.0 0.06260 Total 10.0 38 37.07 2" Dyna Flow 997 2.2030 TJ8EE Len 218.3 Ftg 35.5 C= 120 Pt 104) 50.681 Fe 0.000 Pt 59.912 104 37.07 BL 194.6 0.23614 Total 253.7 18 36.24 2" Dyna Flow 2.2030 1 Len 0.8 Ftg 13.6 C=120 Pt 38) 110.593 Pe 0.359 Pt 3.417 38 37.07 RN 194.6 0.23614 Total 14.5 17 36.24 4" Dyna Flow 194.6 4.3100 0 Len 0 10. Ftg 0.0 C = 120 Pt 18) 114.369 Pe 0.000 Pf 0.324 18 36.24 CMI 389.2 0.03240 Total 10.0 Total Pressure at Node 17) 114.69 psi 102 37.07 2" Dyna Flow 2.2030 Len 10.0 Ftg 0.0 0=120 Pt 101) 50.232 Pe 0.000 Pt 0.002 101 37.07 BL 4.2 0.00020 Total 10.0 103 37.07 2' Dyna Flow 99.2 2.2030 Len 10.0 Ftg 0.0 C = 120 Pt 102) 50.234 Fe 0.000 Pt 0.733 102 37.07 BL 103.4 0.07333 Total 10.0 47 37.07 2" Dyna Flow 99.9 2.2030 T Len 129.3 Ftg 13.6 C 120 Pt 103) 50.967 Pe 0.000 Pt 36.604 103 37.07 BL 203.4 0.25617 Total 142.9 27 36.24 2" Dyna Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 Pt 47) 87.572 Fe 0.359 Pf 3.706 47 37.07 RN 203.4 0.25617 Total 14.5 0 Copyright 2013 Sigma Development Group, Inc. Page 4 of 9 0488 OOOO DashbewdHydraulla Pipe Information SR CARLSBAD OAKS BUILDING B (Remote Area 1) From Elvi Pipe ID Flows Added GPM Inside Diameter Fittings Length ft 1 C Value 1 I Total (Pt) psi Notes Fitting ft I I Elev (Pe) psi To Elev2 Type in Friction Lossl Total Total ft psi/ft j Frict(Pf) psi 26 36.24 4" Dyna Flow 405.7 4.3100 0 Len 10.01 Ftg 0.0 c = i Pt 27) 91.638 Pe 0.000 Pf 0.742 27 36.24 CM2 609.1 0.07420 Total 10.0 Total Pressure at Node 26) 92.380 psi 100 37.07 2" Dyna Flow 2.2030 Len 10.0 Ftg 0.0 C=120 Pt 101) 50.232 Pe 0.000 Pt 0.627 101 37.07 BL 95.0 0.06268 Total 10.0 37 37.07 2" Dyna Flow 995 2.2030 T,8EE Len 218.3 Ftg 35.5 120 Pt 100) 50.859 Pe 0.000 Pf 60.050 100 37.07 BL 194.9 0.23669 17 36.24 2" Dyna Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 Pt 37) 110.909 Pe 0.359 Pt 3.425 37 37.0 RN 194.9 0.23669 Total 14.5 16 36.24 4" Dyna Flow 389.2 4.3100 0 Len 10.0 Ftg 0.0 C= 120 Pt 17) 114.693 Pe 0.000 Pt 0.687 17 36.24 CMI 584.0 0.06865 Total 10.0 - Total Pressure at Node 16) 115.379 psi 46 37.07 2" Dyna Flow Len 0.8 C = 120 Pt 26) 92.380 2.2030 T Ftg 13.6 Pe -0,359 26 36.24 RN 86.8 0.05303 Pt 0.767 Total 14.5 36 37.07 2" Dyna Flow Len 377.5 C = 120 Pt 46) 92.787 2.2030 21 Ftg 27.3 Pe 0.000 46 37.07 BL 86.8 0.05303 Pt 21.465 Tot al 404.8 16 36.24 2" Dyna Flow Len 8 0 . C = 120 Pt 36) 114.253 2.2030 1 Ftg 13.6 Pe 0.359 36 37.07 RN 86.8 0.05303 Pf 0.767 Total 14.5 15 36.24 4" Dyna Flow 584.0 Len 10.0 C=120 Pt 16) 115.379 4.3100 0 Ftg 0.0 Pe 0.000 16 36.24 CMI 670.8 0.08872 Pt 0.887 Total 10.0 Total Pressure at Node 15) 11.261 psi 25 36.24 4" Dyna Flow Len 10.0 C = 120 Pt 26) 92.380 4.3100 0 Ftg 0.0 Pe 0.000 26 36.24 CM2 522.3 0.05583 Pf 0.558 Total 10.0 45 37.07 2" Dyna Flow .434.8 Len 0.8 c = 120 Pt 25) 92.938 2.2030 1 Ftg 13.6 Pe -0.359 25 36.24 RN 87.5 0.05379 Pf 0.778 Total 14.5 0 Copyright 2013 Sigma Development Group, Inc. Page 5 of 9 6 -ik 8OO Dashboard Hydraulics Pipe Information SR CARLSBAD OAKS BUILDING B (Remote Area 1) From Elevi ft Pipe ID Flows Added LGPM Inside Diameter Fittings Length ft C Value ITotal (Pt) psi Notes Fitting ft I Elev (Pe) psi To El ft ev2 j Type in j 1 Lossl psi/ft -lriction Total Total ft Fdct psi 35 37.07 2.2030 21 Len Ftg 27.3 c = 120 Pt 45) 93.357 Pe 0.000 Pt 21,772 45 ____ 37.07 2" DynaEFlow B 0.05379 Total 404.8 15 36.24 2" Dyna Flow 2.2030 1 Len 0,8 Ftg 13.6 = 120 Pt 35) 115.129 Pe 0.359 Pf 0.778 35 37.07 RN 87.5 0.05379 8 36.24 4" Dyna Flow 670.6 4.3100 Len 8.0 Ftg 0.0 c = 120 Pt 15) 116.267 Pe 0.000 Pf 0.890 15 36.24 CMI 758.3 0.11130 Total 8.0 Total Pressure at Node 8) 117.157 psi - 24 36.24 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 C 120 Pt 25) 92.938 Pe 0.000 Pt 0.398 25 36.24 CM2 434.8 0.03977 Total 10.0 44 37.07 2" Dyna Flow -346.5 2.2030 1 Len 0.8 Ftg 13.6 C 120 Pt 24) 93.336 Pe -0.359 Pf 0.792 24 36.24 RN 88.3 0 0 74 Total 14.5 34 37.07 2" Dyna Flow 2.2030 2T Len 377.5 Ftg 27.3 C = 120 Pt 44) 93.768 Pe 0.000 Pt 22.158 44 37.07 BL 88.3 0.05474 Total 404.8 14 36.24 2" Dyna Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 Pt 34) 115.926 Pe 0.359 Pt 0.792 34 37.07 RN 88.3 0.05474 Total 14.5 Total Pressure at Node 14) 117.077 psi 23 36.24 4" Dyna Flow Len 0 10. C = 120 Pt 24) 93.336 4.3100 0 Ftg 0.0 Pe 0.000 24 36.24 CM2 346.5 0.02613 Pt 0.261 Total 10.0 43 37.07 2' Dyna Flow -259.2 Len 8 0. C = 120 Pt 23) 93.597 2.2030 1 Ftg 13.6 Pe -0.359 23 36.24 RN 87.3 0.05354 Pt 0.775 33 37.07 2" Dyna Flow Len 5 377 . C= 120 Pt 43) 94.012 2.2030 2T Ftg 27.3 Pe 0.000 43 37.07 BL 87.3 0.05354 Pf 21.670 Total 404.8 13 36.24 2" Dyna Flow Len 0.8 C=120 Pt 33) 115.682 2.2030 T Ftg 13.6 Pe 0.359 33 37.07 RN 87.3 0.05354 Pt 0.775 Total 14.5 Total Pressure at Node 13) 116.816 psi 0 Copyright 2013 Sigma Development Group, Inc. Page 6 of 9 oo Dashboard Hydraulics Pipe Information SR CARLSBAD OAKS BUILDING B (Remote Area 1) From Elevi ft Pipe ID Flows Added T Inside J Length ft c Value Total (Pt) psi J I Fitting ft I I I Elev (Re) psi I GPM Diameter Fittings I Notes To EIev2 Type in IFriction Loss Total ITothi ft1 psi/ft IFrict(P) psij 22 36.24 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 c = 120 0.01528 Pt 23) 93.597 Pe 0.000 Pt 0.153 23 36.24 CM2 259.2 Total 10.0 42 37.07 2" Dyna Flow -172.6 2.2030 1 Len 0.8 Ftg 13.6 C= 120 0.05283 Pt 22) 93.750 Pe -0.359 Pt 0.764 22 36.24 RN 86.6 Total 14.5 32 37.07 2" Dyna Flow 2.2030 21 Len 377.5 Ftg 27.3 C = 120 Pt 42) 94.154 Pe 0.000 Pt 21.385 42 37.07 BL 86.6 0.05283 Total 404.8 12 36.24 2" Dyna Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 Pt 32) 115.539 Pe 0.359 Pf 0.764 32 37.07 RN 86.6 0.05283 Total 14.5 Total Pressure at Node 12) 116.663 psi 21 36.24 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00720 Pt 22) 93.750 Pe 0.000 Pf 0.072 22 36.24 CM2 172.6 Total 10.0 41 37.07 2" Dyna Flow -86.3 2.2030 T Len 0.8 Ftg 13.6 c = 120 Pt 21) 93.822 Pe -0.359 Pt 0.760 21 36.24 RN 86.3 0.05250 31 37.07 2" Dyna Flow 2.2030 21 Len Ftg 27.3 c = 120 Pt 41) 94,222 Pe 0.000 Pt 21.250 41 37.07 BL 86.3 0.05250 Total 404.8 11 36.24 2" Dyna Flow 2.2030 _______ T ________ 8 Len 0.C= Ftg 13.6 120 Pt 31) 115.472 Pe 0.359 Pf 0.760 _________ 31 37.07 RN 86.3 ______ 0.05250 To tal 14.5 Total Pressure at Node 11) 116.591 psi 20 36.24 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 21) 93.822 Pe 0.000 Pf 0.020 21 36.24 CM2 86.3 0.00200 Total 10.0 40 37.07 2" Dyna Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 Pt 20) 93.842 Pe -0.359 Pf 0.758 20 36.24 RN 86.3 0.05241 30 37.07 2" Dyna Flow 2.2030 21 Len Ftg 27.3 C 120 Pt 40) 94.240 Pe 0.000 Pf 21.213 40 37.07 BL 86.3 0.05241 Total 404.8 © Copyright 2013 Sigma Development Group, Inc. Page 7 of 9 I 88OO SR CARLSBAD OAKS BUILDING B Pipe Information (Remote Area 1 From ______ Elvi ft Pipe ID ' Flows Added GPM Inside Diameter Fittings Length fti C Value - ITotal (Pt) psi Notes Fitting ft I I Elev (Pe) psi To ft Etev2 Type in Friction Loss Total Tothi ftj psi/ft jFrict (Pf) Psi 10 36.24 2" Dyna Flow 2.2030 1 Len 0.8 Ftg 13.6 0=120 Pt 30) 115.454 Pe 0.359 Pf 0.758 30 37.07 RN 86.3 0.05241 Total 14.5 11 36.24 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 0=120 Pt 10) 116.571 Pe 0.000 Pt 0.020 10 36.24 CMI 86.3 0.00200 Total 10.0 12 36.24 4" Dyna Flow 86.3 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 11) 116.591 Pe 0.000 Pf 0.072 11 36.24 CM1 172.6 0.00720 Total 10.0 13 36.24 4" Dyna Flow 86.6 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 12) 116.663 Pe 0.000 Pt 0.153 12 36.24 CMI 259.2 0.01528 Total 10.0 14 36.24 4' Dyna Flow 87.3 4.3100 0 Len 10.0 Ftg 0.0 0=120 Pt 13) 116.816 Pe 0.000 Pt 0.261 13 36.24 CMI 346.5 0.02613 Total 10.0 8 36.24 4" Dyna Flow 88.3 4.3100 0 Len 2.0 Ftg 0.0 = 120 Pt 14) 117.078 Pe 0,000 Pt 0.080 14 36.24 CMI 434.8 0.03977 Total Pressure at Node 8)117.157 psi 4 9.24 10" PVC CL200 9.4200 5EE Len 950.0 Ftg 61.5 0=150 Pt 3) 137.377 Pe 0.000 Pt 0.753 3 9.24 LU 495.7 0.00074 Total 1,011.5 1 9.24 jo' PVC CL200 9.4200 5EE Len 910.0 Ftg 61.5 0=150 Pt 4) 138.130 Pe 0.000 Pt 0.723 4 9.24 LU 495.7 0.00074 Total 971.5 Total Pressure at Node 1)138.853 psi 2 9.24 io" PVC CL200 9.4200 0 Len 350.0 Ftg 0.0 0=150 Pt 3) 137.376 Pe 0.000 Pt 0.864 3 9.24 LU 947.4 0.00247 Total 350.0 1 9.24 10° PVC CL200 9.4200 T,EE Len 180.0 Ftg 68.2 0=150 Pt 2) 138.240 Pe 0.000 Pt 0.613 2 9.24 LU 947.4 0.00247 Total 248.2 Total Pressure at Node 1)138.853 psi 7 36.24 6" Sch 10 6.3570 2E,T Len 15.31 Ftg 72.9 0=120 Pt 8) 117.157 Pe 0.000 Pf 3.420 8 36.24 FM 1,193.1 0.03879 Total 88.2 © Copyright 2013 Sigma Development Group, Inc. Page 8 of 9 d 0 "~4 Dashboard Hydraulics Pipe Information SR CARLSBAD OAKS BUILDING B (Remote Area 1) From Elevi ft Pipe ID Flows Added Inside Length ft 1 C Value I I Total (Pt) )Si Fitting ft Elev (Pe) psi GPM Diameter Fittings I Notes To Elev2 Type in IFrIon Loss Total Total ft psi/ft j Frict (PI) psi 6 9.24 6' Sch 10 Len 30.0 C = 120 Pt 7) 120.577 6.3570 2E Ftg 35,2 Pe 11.691 7 36.24 FR 1,193.1 0.03879 Pt 2.529 Total 65.2 3 9.24 8" PVC CL200 7.6800 T,2EIEE, CV,GV Len 90.0 Ftg 161.5 = 150 Pt 6) 134.805 Pe 0,000 Total 251.5 6 9.24 UN 1,193.1 0.01022 pf 2.571 Total Pressure at Node 3)137.376 psi o 0.00 12° PVC CL200 112000 T,4E Len 190.01 Ftg 185.9 C = 150 Pt 1) 138.853 Pe 4.001 Pt 0.870 4 psi loss for DDC shown as elevtion 1 9.24 UN 1,443.1 0.00231 Total 375.9 Total Pressure at Node 0)143.724 psi 0 Copyright 2013 Sigma Development Group, Inc. Page 9 of 9