Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2525 EL CAMINO REAL; 145; FPC2018-0332; Permit
Permit No: FPC2018-0332 CARLSBAD, CA 92008-1207 Work Class: Fire Alarm Track #: Lot U: Project U: Plan U: Construction Type: Orig. Plan Check#: Plan Check #: Status: Closed - Finaled Applied: 10/05/2018 Issued: 02/11/2019 Finaled Close Out: 02/11/2019 Inspector: Final Inspection: PERMIT REPORT C' City of Carlsbad Print Date: 01/20/2022 Job Address: 2525 EL CAMINO REAL, # 145, Permit Type: FIRE-Construction Commercial Parcel #: 1563022700 Valuation: $31,626.80 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: WETZELS PRETZELS -FIRE ALARM TI Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 1 I www.carlsbadca.gov SimplexGrinnell LP 3568 Ruffin Road atwLj1,:,Sa nmia 92123 P: 858-633-9100 SimplexGrinnel/ i xg1Onnneii.com Fire Detection and Alarm System Product Submittal Project: Wetzel Pretzel The Shoppes at Carlsbad 2525 El Camino Real Suite 145 Carlsbad, CA pp.. I LT U"'A- \.: FPC2018-0332 2525 EL CAMINO REAL #145 WETZELS PRETZELS - FIRE ALARM TI 1563022700 10130/2018 FPC20I8-0332 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douqlas.danieIs(äici.com 10/2/2018 REV.#: 0 PROJECT Safer. Smarter. Tyco .TM tqco SimplexGrinnell SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com Fire Detection and Alarm System Products Qty Model No. Description 1 4090-9010 Relay lAM 2 4906-9204 Strobe 2 49SV-APPLC Speaker Strobe 2 49SVH-APPLC Speaker Strobe C.S.F.M. No. 7300-0026:0311 7125-0026:0235 7125-0026:0384 7125-0026:0384 Business Information Warranty Information 10/2/2018 REV.#: 0 PROJECT Safer. Smarter. Tyco .TM * !iSimplEx Multi-Application Peripherals UL, ULC, CSFM Listed; IDNet Communicating Devices FM Approved* Model 4090-9010, 8 A Relay lAM I1ti I Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 11/ square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 Description 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. "M7 ~M&Tgffm-ffl Model Description 4090-9010 8 A Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 For semi-flush Trim plate, galvanized mounted box steel, with LED viewing For surface window; includes 4090-9802 mounted box mounting screws 4090-9813 I Adapter plate to fit 4 (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) IDNet communications 1 address per Communications device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* not rated for incandescent switching) Type Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4WHx4"Wx1 %"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range I Up to 93% RH at 100° F (38° C) S4090-0015-1 11/2014 8 A Relay lAM Mounting Information 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © -- Add suIiz=mvKmomii6 A--pplied labe me = pull l I AVTISS1T: cover on-site if controlling Avwnssaer:I 4-9/16" 120 or240VAC 4-5/16" (1116 mm) "09 mm) Light pipe for LED viewing © © © © 4-9/16' (116 mm) 10 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohbited. J3,SIMpJlEX Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4090-0015-1 11/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL IKE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *4090..9010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division d.S'1MP1r:X TrueA!ert Addressable Notification Appliances UL, ULC, CSFM Listed, FM Approved; Multi-Candela Visible Only (VIO) MEA (NYC) Acceptance* LftJ Appliances (Strobes), Ceiling Mount I1I I 1*1 Individually addressed and controlled multi-candela VIO (visible only) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, or 110 cd Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup Wiring supervision to each strobe allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 2) Magnet test diagnostics to assist checkout and testing of appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see page 3) UL listed to Standard 1971 and ULCS526* LED indicator and magnet test feature: Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address AND pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features: Rugged, high impact, flame retardant ceiling mount thermoplastic housings are available in red or white Rear of housing does not extend into box and easily mounts to standard electrical boxes Mounting options include red wire guards and adapters for surface mounted electrical boxes * See page 2 for wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:235 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Ceiling Mount Addressable V/Os I BIT=. MR! Multi-Candela TrueAlert addressable strobes provide convenient installation to standard electrical boxes. The strobe is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 3.) FiT1 IYETIMPTIM Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117. 1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). II'] 4i i1ii .i iITY.Trip7Th!J TrueAlert addressable appliances on IDNAC SLCs provide separate visible (and audible) notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. S4906-0004-4 2/2015 Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. TrueAlert Addressable Wiring Isolator Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (Refer to data sheet S4905-0001 for additional information.) log-301imm. -IrliM M. [M Test Features. Controllers can be selcted to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test. In this test mode, in response to the magnet test, the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Testing. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Product Selection Multi-Candela Ceiling Mount Addressable Strobe Model Color Housing FIRE Lettering Dimensions 4906-9202 Red White 4 /" x 2 6 " x 2 %" D 4906-9204 (121 mm x 75 mm x 67 mm) Description Multi-Candela Addressable Strobe; intensity selectable as: 15, 30, 75, or 110 candela VIO Adapters (see diagram on page 3) Model Description Dimensions 4905-9910 Surface Mount Adapter Ceiling Mount,Plate, zinc plated; required for 4 W x 3 ¼" (124mm x 79mm) ceiling surface mount Wire Guards (see diagram on page 3) Model Description Dimensions 49059926* Ceiling Mount Red wire guard with mounting plate, compatible with 6 W 4 % x 2 ¼ semi-flush or surface mounted boxes (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc. TrueAlert Device Reports Reference Service REPORT 5 Port : TrueAlert Device Report Page 1 12:34:56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label . . . up to 40 characters V/a 15 T14-1-2 Break Room 5 A/V 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 30 S4906-0004-4 2/2015 [Eeiiing Mount V/O and Guard Installation Reference /F i (Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or Single gang box (Wiremold V5744S) -LL I I equal) or single gang box, 2-1/2" (64 mm) deep 2-1/4" (57 mm) deep, supplied by others J (RACO 519 or equal) supplied by others ,! Also can be attached to boxes mounted to drop I ) / ceiling T-bar with clips (ERICO No. 512 or equal) Address setting DlPswitch is behind strobe V ' / assembly, select address and strobe candela setting before inserting into housing Ii' I /' 4905-9910 Adapter Plate, required for surface mount with handy box unless using the 4905-9926 ) / wire guard Bottom view. Magnetic ----t , •, ,, Ceiling mount strobe test location r - -. - Optional 4905-9926 wire 1 LI guard with mounting plate Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is FACP, LED indicator/ I.------------controlled by panel - IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC I 29 VDC (regulated) S4010-001 1 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4007E5 with IDNAC Notification I S4007-0002 40I0ES with ESS Enhanced System Supply General Specifications (see page 2 for dimensions) Environmental 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Installation Instructions 579-808 Strobe Specifications - -- Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application (see below for 17 VDC rating) Supervisory Requirements I unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 46 synchronized strobes maximum per NAC Candela Setting 15 cd I 30 cd 75 cd I 110 cd 23 VDC RMS Current Ratings, for connection to IDNAC Addressable SLCs 60 mA 92 mA 180 mA 240 mA I TrueAlert Strobe LEGACY Compatibility Reference Compatible Controller Data Sheet Reference Controller Output Available Strobe Intensity Appliance Voltage Minimum 4100ES or4100U with TrueAlert Power Supply S4100-0031 TrueAlert Addressable SLC 15, 30, 75, and 110 cd .17 VDC 4009 TPS, Remote TrueAlert Power Supply S4100-0037 TrueAlert Addressable Controller (4009T) S4009-0003 Electrical Ratings Difference for Retrofit Applications Voltage Range 17 VDC to 31 VDC, Special Application Candela Setting 15 cd 30 cd 75 cd 110 cd 17 VDC RMS Current Ratings, use when connected to TrueAlert Addressable SLCs per 76 mA 128 mA 242 mA 328 mA above S4906-0004-4 2/2015 TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). Sirn I EX Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4906-0004-4 2/2015 www.simplexgnnnell.com 02015 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7125-0026:0235 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models "TrueAlert non-addressable " 4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable "4904-9168, 4904-9171, 4904-9169, 4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904-9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904-9360, 4909-9361 synchronized strobe lights. Models "TrueAlert addressable" 4906-9201, -9202, -9203, -9204, and -9208 synchronized multi-candela strobe lights are intended for indoor use. *Models 4906-9201, -9203 and -9208 are intended for wall mount only. *Models 4906-9202 and -9204 are intended for ceiling mount only. Intended for use with either Model 4209-9401 NAC Extender or with the TrueAlert power supply of Model 41001.1 fire alarm control panel. Model 4906-9208 employs two lenses, clear lens for "Fire" and amber for "Non-Fire". Model 4905-9938 sync control module. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, -9353, -9356, -9359, -9168, -9171: 15cd, 1 Hz. 4904-9332, -9343, -9351, -9354, -9357, -9360, -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, -9352, -9355, -9358, -9361: 110cd, 1 Hz. Models 4906-9201, -9202, -9203, -9204, -9208: 15, 30, 75, 110cd, 1 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. *Rev 04-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division B®5implEx TrueAlert Addressable Notification Appliances UL, ULC Listed* ___ Wall and Ceiling Mount Addressable Speaker L and Speaker Visible Notification Appliances I1uii*i Individually addressed and controlled Speaker (5/0) and Speaker Visible (SN) notification appliances Advanced addressable notification controlled by IDNAC SLCs provides regulated 29 VDC for low current operation even under battery backup. Wiring supervision is electronically monitored and allows audio wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Speaker selectivity is controlled by the panel. Only those speakers that are needed are connected to the audio NAC. Separate appliance and cover selection greatly simplifies the ordering and installation process. Strobe intensity can be programmed from the control panel or the device for S/V models. Self-Test Mode allows on-board sensors to detect the strobe and speaker output and then report their status to the control panel. Wiring terminals separate from the Audio terminals. TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting. Magnet test diagnostics to assist checkout and testing of appliances and wiring. Compatibility with ADA requirements. LED indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address and pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount models Covers are available in red or white with various lettering options Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts to 4" square 2 ¼" gang US electrical boxes Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Ceiling and Wall Mount Addressable Speaker Only and Speaker Visible Strobes I Speaker design features High quality voice and tone reproduction with taps for ¼, '/2, 1, or 2W, at 25 or 70.7 VRMS Speakers have capacitor input for connection to DC supervised NACs and are wired separately from strobes Listed toUL 1480 and ULC S541* Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas High and low frequency response models available, 200-10000 Hz and 400-4000 Hz respectively. Wall and ceiling mount addressable speaker and speaker visible appliances provide convenient installation to standard electrical boxes. The speaker is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). Audio is provided by a panel that supports audio output or from a separate audio source. Appliances use a multi-tapped speaker for audio/tone notification. FITYTj1ITtT1 fltiit* Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S49SWC-0001-1 11/2015 II'] Z r 9I1 .I1.i .NlITiYT L'flhlTi TrueAlert Addressable speaker and speaker visible appliances on IDNAC SLCs provide visible and audio notification using two separate two-wire circuits that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. TM Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. rTri ri.i ']i, Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance's address when a magnet is applied. Operational Appliance Testing In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test JDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. I'fl II rnI..1l iitiTT rTr1.-flr !U Wall Mount SIO Appliances* (Refer to data sheet S49SOW-0001 for full product selection including covers and mounting plates) Model Dimensions Description Data Sheet Reference 49S0-APPLW(-BA) 15 Y2 H x 5' W x 1 1/2" D Sf0 appliance only S49Sow-0001 49HF-APPLW(-BA) (139 mm x 128 mm x 38 mm) I High fidelity S/O appliance only Wall Mount SN Appliances* (Refer to data sheet S49SVW-0001 for full product selection including covers, mounting plates, and multi-color strobe lens) Model Series Dimensions Description Data Sheet Reference 49SV-APPLW(-BA) 7 %" H x 5" W x 1 %" D S/V appliance only s495vw-000l 49HFV-APPLW(-BA) (187mm x 128 mm x 43mm) High fidelity SN appliance only *Note: Wall mount models require separately ordered back plate. See related datasheet for details Ceiling Mount Appliance Product Selection Ceiling Mount SIO Appliances (Refer to data sheet S49SOC-0001 for full product selection and installation requirements) Model Dimensions Description Data Sheet Reference 49S0-APPLC(-BA) 7 V8' H x 7 %' W x 1 1/4" D Sf0 appliance only S49SOc-0001 49HF-APPLC(-BA) 1180 mm x 180 mm x 32 mm) High fidelity Sf0 appliance only \'\ Ceiling Mount SN Appliances (Refer to data sheet S49SVC-0001 for full product selection and installation requirements) Model Series Dimensions Description Data Sheet Reference \ 49SV-APPLC(-BA SN aooliance only I Hicih fidelity SN aooliance only I 49SVH-APPLC(-BA) 8Ya"Hx7Y"Wx3"D 49HFVH-APPLC(-BA) (206 mm x 180 mm x 76 mm) 49HFVH-APLCA-BA 49HFVH-APLCB-BA Clear lens high fidelity high candela SN aooliance only I S49SVC-0001 candela SN appliance only Blue lens high fidelity high candela SN aooliance only Note: Select appliance, cover and mounting back plate (where required) separately. (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA S49SWC-0001-1 11/2015 IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 4100ES with EPS+ orEPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 4100E5 Constant Supervision and Signal Cards Specifications General Specifications (refer to individual model data sheets for further specifications, install and operation details) Typical Operating Voltage Range 23 - 30 VDC, Special Application Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm' to 3.31 mm'); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible fire panel installation instructions for circuit current load limits. Speaker Specifications 25 or 70.7 Vrms Power Taps I ¼,1/zl, and 2W 400 to 4000 Hz and 200 to 10000 Hz, Frequency Response General Signaling = 125 to 12 kHz respectively. Strobe Specifications Typical Operating Voltage Range 23 - 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate 1 Hz IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) UTP, unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 ft (3048 m) Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Note: Speakers are for connection to compatible fire alarm audio circuits only. S49 Series Speaker Datasheet Reference Model Data Sheet Reference Wall Mount Speaker Only Appliance S49SOW-0001 Wall Mount Speaker Visible Appliance S49SVW-0001 Ceiling Mount Speaker Only Appliance S49SOC-0001 Ceiling Mount Speaker Visible Appliance S49SVC-0001 S49SWC-0001-1 11/2015 TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prchibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®S i iii p1 EX Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S49SWC-0001-1 11/2015 www.simplex-fire.com 0 2015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette©jci.com DESIGN: Models: 495V-APPLC,49HFV-APPLC,49SV-APPLC-BA,49H FV-APPLC-BA,495VH-APPLC-BA, 49HFVH-APPLC-BA,495VH-APPLC,49HFVH-APPLC,49SV-CWF,49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 495V-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF, 49HFV-WRF, *49svAppLW.0 *49SVAPPLW0BA *49SVAPPLWCO True Alert ES, Addressable wall mounted Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor and outdoor use. Refer to listee's Installation Instruction Manual for details. *Revision 04-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV1 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SimplexGrinnel! LP 3568 Ruffin Road, South tq San Diego, CA 92123-2597 Tele: (858) 633-9100 ell Fax: (858) 633-9101 www.simplexgrinnell.com License Number 986047 Business Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2019 This license is current and active. All information below should be reviewed. Classifications dO - ELECTRICAL C16 -FIRE PROTECTION CONTRACTOR Bonding Information Contractors Bond This license filed '—a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History -- Bond of Qualifying Individual - This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for TIMOTHY PAUL ROSTEN in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC308342 Effective Date: 10/01/2016 Expire Date: 10/01/2017 Workers' Compensation History Other Personnel listed on this license (current or disassociated) are listed on other licenses. $/1/2017 . . . . REV.#; 0 . PROJECT #: 480-XX)(XXX-XX / XXXXXXXXX i-ersonnel listed on this license (current or disassociated) are listed on other iicenses. tqca SimplexGrinnell SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST 10/4/2016 REV.#: 0 PROJECT #: 480-X)O(XXX-XX/XXXXXXXXX