HomeMy WebLinkAbout2525 EL CAMINO REAL; 211; FPC2019-0021; PermitPERMIT REPORT iity of Carlsbad Print Date: 02/16/2022 Job Address: 2525 EL CAMINO REAL, #211, Permit Type: FIRE-Construction Commercial Parcel #: 1563022700 Valuation: $105,040.56 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: BESHOCK RAM EN -FIRE ALARM TI CARLSBAD, CA 92008-1208 Work Class: Fire Alarm Track #: Lot #: Project U: Plan U: Construction Type: Orig. Plan Check U: Plan Check U: Permit No: FPC2019-0021 Status: Closed - Finaled Applied: 02/05/2019 Issued: 04/02/2019 Finaled Close Out: 01/28/2020 Inspector: Final Inspection: Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov IG tq;;U I SimpiexGrJnnell SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F858-633-9101 www.simplexgrinnell.com FPC2_019-ooZ( Fire Detection and Alarm System Product Submittal Project: BESHOCK The Shoppes at Carlsbad 2525 El Camino Real Suite 211 Carlsbad, CA For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douqlas.daniels(ä!jci.com 2/4/2019 REV.#: 1 PROJECT Safer. Smarter. TYCO.TM tqco SimpiexGrinnell SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 1 4098-9755 Duct Detector 3240-0026:0241 1 2098-9806 Remote Test Station 7300-0026:0150 1 4090-9001 Addressable 1AM 7300-0026:0223 2 4090-9010 Relay [AM 7300-0026:0311 3 4906-9204 Strobe 7125-0026:0235 4 49S V-APPLC Speaker Strobe 7125-0026:0384 Business Information 2/4/2019 REV.#: 1 PROJECT Safer. Smarter. T,/co.Tm E5®Simplex TrueAlarm® Analog Sensing UL, ULC, CSFM Listed, FM Approved, Addressable Duct Sensor Housings with lrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control Iiii Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed lrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via 1IDNetTM or MAPNET 110, 2-wire communications t Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by 1DNetIMAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: . UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interlace board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning mater/al presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest Status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Duct Sensor Housing, Front and Bottom View 0 II 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station liii! ['I'll LII! 'ii. Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. irr pj iiE11ii*] &'I.I] itso 1 Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarrn sensors and IDNet and MAPNET II communications are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5400,014; 5,543,777; 5,710,541; D383,407; 0388352; D392,573; 4796,025. S4098-0030-5 3/2007 Photoelectric Sensing (Continued) Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. '. Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control \Duct r'Char1 for ON, OFF, or override Sensor Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description I Compatibility Basic Duct Sensor Housing; operating power i3 supplied b" Simplex fire alarm control panel models 4010, 4098-9755 4020, 4100, 4100U, and 4120. Also 2120 CDT if either IDNet or MAPNET II communications (n3 ,elay output) configured for MAPNET II, TrueAlarm operation Duct Sensor Housing with supervised multiple -.,elay output, Same as above except relay operation is not 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 compatible with 2120 CDT; end-of-line resistor harness; includes one 4095-984:3 relay Relay output is for up to 15 total 4098-9843 Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator Use single gang box, 2098-9806 Test Station with keyswitch and red LED status hdicator 4098-9755 4098-9756 3" H x 2" W 2" D (turning switch to "TEST" initiates alarm for systen testing) (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9756 only; Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; connect u p o (1 m) of device being wiring is 18 AWG (0.82 mm2 ) color coded wire leads controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kcl, 1/2W; (re. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connecticn * Each duct housing includes an internally mounted model 4098-9714 TueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer ic' chart below. Sampling Tube Selection Chart, Ordered Separately Per Duct Width, Select One Overall Duct Width (305 mm) Tube Requird 2098-9796 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46' (610 mm to 1168 mm) 2098-9797 2" (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2" (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2" (51 mm) longer than duct width S4098-0030-5 3/2007 kIT1iF1diiII1.]gSJ.I] rTY(ThIThFIJ Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) ItT1T1flT TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. iitt Snsnr Hniisinn flt NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information 11-3/8' (289 mm) - [Exhaust tube access hole I [_Conduit (by othersJ IWN- I• f 40c)8-9714 Smoke sensor, mounted interface base [ in special (supplied) i Metal plate with dual holes S for 3/4" (19 mm) conduit, plug supplied for unused hole 0 000 (171 m Sampling tube Yellow LED, relay ontrol trouble indicator (4098 56 only) access hole 'Red sensorl Ewa status LED J ofducD. f x - -. Wiring terminals) [tionary baffle (built [Captive fastening screws (4)1 [Magnetic test area Mount as shown (preferred) or (Transparent cover eted sensor area with electronics area located to the LEFT or UP ONLY lif 3-3/8" (86 mm) (21 mm) 71 Test ports (2) provided for measuring airflow and for aerosol injection Sampling tube, ordered separately per duct width Exhaust tube (supplied) Duct wall End View with Duct and Tubes 118" Round duct outline1 Duct housing J (minimum diameter) 1"" I Exhaust tube Square duct outline (minimum width) J S S S S J Sampling tube, keyed for proper hole alignment with holes facing into airflow (template is provided for proper tube installation) 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 137/16" (38 mm) 1-3/16" (30 mm) 3 S4098-0030-5 3/2007 Ill Iii ii.i Exhaust Sensor Damper OK Exhaust -Return Air Do not locate sensor here Return air damper Fresh Supply air Air ot locate Filter" - Sensor bank OK sensor hero Bend or obstruction 6 Duct nle " Return a> 6 Duct widths widths minimum -°1 5 minimum Preferred Duct Sensor Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. 11Is]i General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.21/ to 37% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F tc 100° F (0° C to 38° C) Operating Temperature Range 32' F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal olocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Remote Status/Alarm LED and Test Station with Remote Alarm LED Current Black bare with clear cover Remote Status/Alarm LED 1.2 mA, ro impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, r impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation Data Communications lDNe: or MAPNET II communications, auto-select, one address per housing; a a pmvides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Cointroe, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage I 18-32 VDC (24 VDC nominal) Standby Current 13 mA @ 24 VDC Alarm Current (one relay activated) 115 mA @. 24 VDC; add 15 mA for each additional remote 4098-9843 relay Supervised Remote Relay Control Output 4098-9843 Relay Output Ratings, Single Form Coil Current Relay Contacts For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 f (152 in) maximum; requires 4081-9008 (ref. 733-894) 10 kc, 1/2 Wend-of-line rEsis:or use with Model 4098-9756 Only 1 mA © 24 VDC, up to 15 maximum per relay control output 7Aat 0.35 PF@28 VDC& 120 VAC 2E•0iAc5VDC Location Distance 5:0 t (152 m) maximum to relay coils; relays must be within 3 ft (1 m) of device being controlled per NFPA 72 Tyco, Simplex, the Simplex logo, TrueAlarm, IDNet, and MAPNETII are trcde'nsrks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks oft'_- Nst°oral Fire Protection Association (NFPA). .Simplex93 Tyco Safety Products Westminster• Westminster, MA • 0144 1-0001 USA S4098-0030-5 3/2007 www.tycosafetyproducts-usa-wm.com 02007 Tyco Safety Products Westminster. All rights reserved All speci/i cations urdc.,her information shown were current as ofdocument revision dote and are subject to change wit/inst notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL MOM FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098-9755, *4098..9755TSp *4098..9755up 4098-9756, *4098..9756T5p *4098..9756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Rev. 11-06-03 9Ti This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7300-0026:0150 - Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES SimplexloO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Mcdel 4098-9835 remote power/alarm indicator with test switch; Model 2C38-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test swtch. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applcabe :odes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended or use with duct smoke detectors. Model 2098-9816 is intended for use wzh projected beam detector systems. RATING: INSTALLATION' MARKING: APPROVAL: NOTE: *Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent 'lerifalion of any calms. This listing is not an endorsement or recommendation of the item listed. This listing siojld not be used to verify co-,-e--t cperational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or cther Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorizec Bj: DAVID CASTILLO, Program Coordinator Fire Engineering Division £LSimpIEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* liii 1(41 IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from JAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Simplex control panels: Model Series 4007ES, 4008, 4010, 4010ES, and 4100E5 fire alarm control panels for IDNet communications Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings maybe applicable contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet and MAPNET II Communicating Devices, Individual Addressable Modules (lAMs) 4090-9001 Supervised 1AM (shown approximately 3/4 size) 4090-9051 Supervised lAM (shown approximately 3/4 size) Ds tori nti r Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. 1.011111111111115 D n rati r Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). [Iiuii.i ii mTrtsj ii For use with IDNet communications only, these JAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. I rii 1TTI1 rri Model Description 4090-9001 1 Supervised lAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 1 Supervised lAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mcunting screws; galvanized steel 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No Description 4081-9004 733-886 6.8 1/2 W; Standard enc-of-line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 kc, 1/2W 4081-9005 733-984 1.8kc,1/2W Use for current, limited monitoring applications Specifications Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per lAM Input Requirements Normally open, dry contacts Wire Connections 4090-9001 4090-9051 Sc-ew terminals for in/out wiring, 18 to 14 AWG wire (0.32 mm2 to 2.08 mm2) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9151 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from lAM to Contacts 503 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 4090-9001 4090-9051 1-9/16"Wx 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) 1-9116"Wx1-9116"H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 158° F (0° to 70° C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) S4090-0001-11 11/204 Mounting Information 4090-9001 IDNet Field wiring shown supervised lAM for reference LED viewing port Single gang electrical box 2-1/2' (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 4-1/4" (108 mm) c Light pipe for © _______ LED viewing 1 (114 mm) DISCONNEcT POWER DISCONNEcT POWER BEFORE SERVICING L8° SEFCING © © "C~D 2-1/2" __ (64 mm) 4090-9806, Trim plate for semi-flush mounted box 2-13/16" 10 (72 mm) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 2 S4090-0001-11 11/2014 4090-9051 Mounting Information Address setting is at rear of housing 4090-9051 Encapsulated Supervised I Single gang electricai box 2-1/2" (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) B Si ni I EX Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4090-0001-11 11/2014 www.simplex-fir,e.com 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revisb.i date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexlOo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised IAM Monitor Module; 4090-9002, -9002T5P, and -90021TP lAM Relay Module; 4090-9106, -9106T5P, and-9I06TTP Class "A" ZAM Initiating Module; 4090-9101, -9I0ITSP, and -9I01TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: *Rece 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 55im plEx UL, ULC, CSFM Listed; FM Approved* I tuM_ Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 "/16" 1/ square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 I'i*iF1IM 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Model Description 4090-9010 BA Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 For semi-flush Trim plate, galvanized mounted box steel, with LED viewing 4090-9802 For surface window; includes mounted box mounting screws 4090-9813 Adapter plate to fit (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9010, 8 A Relay lAM ©cs j1 4090-9010 8 A lDNet Relay lAM Package (shown approximately 1/2 size) bl= WWI Communications IDNet communications 1 address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type Separate contacts; 1, NO and 1 NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 208 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4V3"Hx4"Wx1 %"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) S4090-0015-1 11/2014 8 A Relay lAM Mounting Information 4" (102 mm) square box, 2-118" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use whei LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © ILl 1 © © 1 C NARNM Add supplied label to---,, cum ,IDIItIII I IAvERnssaENrI cover on-site if controlling IAvmIssae4T:I 4-9/16" !h10hlT 120 or 240 VAC no 4-5/16" (116 mm) ii i i (109mm) S Light pipe for LED viewing © © © - -9/16"(116mrn) 1 4-5/16(109mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED 27CO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. ®SirT1pIEX Tyco Fire Protection Proaucts• Westminster, MA •01441-0001 • USA S4090-0015-1 11/2014 © 2014 Tyco Fire P-otection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are cubject to changs eithoienoticn CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *40909010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 3SimpIEx TrueAlert Addressable Notification Appliances UL, ULC, CSFM Listed, FM Approved; [71 Multi-Candela Visible Only (V/O) MEA (NYC) Acceptance* L.ftJ Appliances (Strobes), Ceiling Mount I 1UI4.1 Individually addressed and controlled multi-candela V/O (visible only) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, or 110 cd Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup Wiring supervision to each strobe allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 2) Magnet test diagnostics to assist checkout and testing of appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see page 3) UL listed to Standard 1971 and ULCS526* LED indicator and magnet test feature: Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address AND pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features: Rugged, high impact, flame retardant ceiling mount thermoplastic housings are available in red or white Rear of housing does not extend into box and easily mounts to standard electrical boxes Mounting options include red wire guards and adapters for surface mounted electrical boxes * See page 2 for wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:235 for allowable values and/or conditions concerning material presented in this document Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable: contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Ceiling Mount Addressable V/Os I Multi-Candela TrueAlert addressable strobes provide convenient installation to standard electrical boxes. The strobe is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 3.) 601MV 7001M. F M., 1iI.( Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert addressable appliances on IDNAC SLCs provide separate visible (and audible) notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. S4906-0004-4 2/2015 Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. rrT 1 NZYM fl11 !1 T1 Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (Refer to data sheet S4905-0001 for additional information.) nT 1fl1T Test Features. Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test. In this test mode, in response to the magnet test, the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Testing. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test lDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Product Selection Multi-Candela Ceiling Mount Addressable Strobe Housing Mode! FIRE Lettering Dimensions Color 4906-9202 Red White 4906-9204 Description Multi-Candela Addressable Strobe; intensity selectable as: 15, 30, 75, or 110 candela 4%"x2 5/16"x2%"D (121 mm x 75 mm x 67 mm) VIO Adapters (see diagram on page 3) Model Description Dimensions 4905-9910 Ceiling Mount Surface Mount Adapter Plate, zinc plated; required for 4%" x 3 1/8" (124 mm x 79 mm) ceiling surface mount Wire Guards (see diagram on page 3) Model Description Dimensions 4905-9926* Ceiling Mount Red wire guard with mounting plate, compatible with 6 1/a" X 4 Ya" x 2 7/s" semi-flush or surface mounted boxes (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc. TrueAlert Device Reports Reference Service REPORT 5 Port : TrueAlert Device Report Page 1 12:34:56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label . . . up to 40 characters V/O 15 T14-1-2 Break Room 5 A/V 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 30 2 S4906-0004-4 2/2015 Ceiling Mount V/O and Guard Installation Reference n i (Handy box, 1-1/2" (38 mm) deep (RACO 650 or Single gang box (Wiremold V5744S) 2-1/4" (57 mm) deep, supplied by others - — - I - I /,—><---- El housing; factory setting is FACP, ---------------- ----------------------------------------- Strobe intensity viewing slot Intensity accessible only from rear of lens Bottom view Magnetic selection plug, IDNAC SLC Controller Compatibility Reference ut Compatible Controllers Reference Controller Outp Voltage Design Reference Data Sheet IDNAC SLC Output Appliance Voltage 4009 IDNAC Repeater S4009-0004 29 VDC 23 VDC 4007ES with IDNAC Notification S4007-0002 (regulated) (with 6 VDC drop) 4010ES with ESS Enhanced System Supply S4010-001 1 4IOOES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC Specifications General Specifications (see page 2 for dimensions) Environmental 132° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per I terminal for in/out wirina Installation Instructions 579-808 Strobe Specifications Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application (see below for 17 VDC rating) Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 46 synchronized strobes maximum per NAC Candela Setting 15 c 30 c 75 c 110 c 23 VDC RMS Current Ratings, for connection to 60 mA 92 mA 180 mA 240 mA IDNAC Addressable SLCs TrueAlert Strobe LEGACY Compatibility Reference Compatible Controller Data Sheet Controller Output Available Strobe Appliance Voltage Reference Intensity Minimum 4100ES or 4100U with TrueAlert Power Supply S4100-0031 Addressable SLC 110 cd .17 VDC 4009 TPS, Remote TrueAlert Power Supply S4100-0037 TrueAlert 15, 30, 75, and TrueAlert Addressable Controller (4009T) S4009-0003 Electrical Ratings Difference for Retrofit Applications Voltage Range 17 VDC to 31 VDC, Special Application Candela Setting 15 c 30 c 75 c 110 c 17 VDC RMS Current Ratings, use when connected to TrueAlert Addressable SLCs per 76 mA 128 mA 242 mA 328 mA above S4906-0004-4 2/2015 Address setting DlPswitch is behind strobe assembly, select address and strobe candela setting before inserting into housing test location equal) or single gang box, 2-1/2 (64 mm) deep Q mount with handy box unless using the 4905-9926 wire guard Ceiling mount strobe Optional 4905-9926 wire I ' (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 11 4905-9910 Adapter Plate, required for surface G/ ii guard with mounting plate ••0 LED indic LI TYCO, SIMPLEX aid the product names listed in this materia' are marks acd'or regfsteredmoks. Uzazjhorfted use is strictly prohibited. NFPA 72 and Nat!on21 Fire Alarm and Signaling Code are registered trademarks of the National Fire Prolecnion Association WFFA) S.Simplex Tyco Fire Protection Products• Westminster MA • 01441-0001 • USA S4906-0004-4 2/2015 www.simpèxgrirnel1.c3rn 0 2015 Tyco Fire Protection Products. All rights reserved All specifications and ther information shown wire c-urrertas of document revision date and are subie.t to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0235 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: SimplexlOO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models "TrueAlert non-addressable "4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable '4904-9168, 4904-9171, 4904-9169, 4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904-9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904-9360, 4909-9361 synchronized strobe lights. Models "TrueAlert addressable" 4906-9201, -9202, -9203, -9204, and -9208 synchronized multi-candela strobe lights are intended for indoor use. *Models 4906-9201, -9203 and -9208 are intended for wall mount only. *Models 4906-9202 and -9204 are intended for ceiling mount only. Intended for use with either Model 4209-9401 NAC Extender or with the TrueAlert power supply of Model 4100U fire alarm control panel. Model 4906-9208 employs two lenses, clear lens for "Fire" and amber for "Non-Fire". Model 4905-9938 sync control module. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, -9353, -9356, -359, -9168, -9171: 15cd, 1 Hz. 4904-9332, -9343, -9351, -9354, -9357, -9360, -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, -9352, -9355, -9358, -9361: 110cd, 1 Hz. Models 4906-9201, -9202, -9203, -9204, -9208: 15, 30, 75, 110cd, 1 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. Rev 04-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5SimpIEx TrueAlert Addressable Notification Appliances UL, ULC Listed* Wall and Ceiling Mount Addressable Speaker [TI Hf and Speaker Visible Notification Appliances I1(uI(*1 Individually addressed and controlled Speaker (SIO) and Speaker Visible (SN) notification appliances Advanced addressable notification controlled by IDNAC SLCs provides regulated 29 VDC for low current operation even under battery backup. Wiring supervision is electronically monitored and allows audio wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Speaker selectivity is controlled by the panel. Only those speakers that are needed are connected to the audio NAC. Separate appliance and cover selection greatly simplifies the ordering and installation process. Strobe intensity can be programmed from the control panel or the device for S/V models. Self-Test Mode allows on-board sensors to detect the strobe and speaker output and then report their status to the control panel. Wiring terminals separate from the Audio terminals. TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting. Magnet test diagnostics to assist checkout and testing of appliances and wiring. Compatibility with ADA requirements. LED indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address and pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount models Covers are available in red or white with various lettering options Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts to 4" square 2 %" gang US electrical boxes * Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Ceiling and Wall Mount Addressable Speaker Only and Speaker Visible Strobes ii' I(-I[71rn11?TiiI Speaker design features High quality voice and tone reproduction with taps for '/4,V2,1,or2W,at250r70.7VRMS Speakers have capacitor input for connection to DC supervised NACs and are wired separately from strobes Listed to UL 1480 and ULC S541* Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas High and low frequency response models available, 200-10000 Hz and 400-4000 Hz respectively. I II*.1ii .Utólil Wall and ceiling mount addressable speaker and speaker visible appliances provide convenient installation to standard electrical boxes. The speaker is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). Audio is provided by a panel that supports audio output or from a separate audio source. Appliances use a multi-tapped speaker for audio/tone notification. rrtri Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S49SWC-0001-1 11/2015 I TrueAlert Addressable speaker and speaker visible appliances on IDNAC SLCs provide visible and audio notification using two separate two-wire circuits that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. rir rn1 iF1 0 Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance's address when a magnet is applied. Operational Appliance Testing In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. IAflII rnI.Ti wrilm 1I rTrL-f FMIU Wall Mount SIO Appliances* (Refer to data sheet S4950\/V--)001 for full product selection including covers and mounting plates) Model Dimensions I Descnption Data Sheet Reference 49S0-APPLW(-BA) 5 1/2' H x 5" W x 1 ½" D Sf0 a tance only I S49SOW-0001 49HF-APPLW(-BA) 1(139 mm x 128 mm x 38 mm) High fidelity SIO appliance only Wall Mount SN Appliances* (Refer to data sheet S49SVW-0001 for full product selection including covers, mounting plates, and multi-color strobe lens) Model Series Dimensions Des..ription Data Sheet Reference 49SV-APPLW(-BA) 7 WH x 5" W x 1 3/4" D S/V appliance only —d 5495VW-0001 49HFV-APPLW(-BA) (187 mm x 128 mm x 43 mm) I High fidelity SN appliance only *Note: Wall mount models require separately ordered back ple.. See related datasheet for details. Ceiling Mount Appliance Product Selection Ceiling Mount SIO Appliances (Refer to data sheet S49SOC-003I for full product selection and installation requirements) Model Dimensions Description Data Sheet Reference \ 49S0-APPLC(-BA) 7 1/a H x 7 ½" W x 1 Y4' D S/C appliance only S49S0c-0001 49HF-APPLC(-BA) (180mm x 180mm x 32mm) I Higi fidelity Sf0 appliance only '\ Ceiling Mount SN Appliances (Refer to data sheet S49SVC-0001 for full product selection and installation requirements) Model Series Dimensions Decription Data Sheet Reference 49SV-APPLC(-BA) SI, appliance only 49HFV-APPLC(-BA) Higi fide ity SN appliance only 495VH-APPLC(-BA) Hig-t candela SN appliance only 8Y8"Hx7Ya"Wx3"D Clear lens high fidelity high candela 49HFvH-APPLC(-BA) (206 mm x 180 mm x 76 mm) S/' appliance only S49SVC-0001 Amner lens high fidelity high 49HFVH-APLCA-BA carea SN appliance only Blua lens high fidelity high candela 49HFVH-APLCB-BA I I S/V appliance only I Note: Select appliance, cover and mounting back plate (where required) separately. (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are asserthled in the USA S49SWC-0001-1 11/2015 IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 4100ES Constant Supervision and Signal Cards Specifications General Specifications (refer to individual model data sheets for further specifications, install and operation details) Typical Operating Voltage Range 23 - 30 VDC, Special Application Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mmz to 3.31 mm'); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible fire panel installation instructions for circuit current load limits. Speaker Specifications 25 or 70.7 Vrms Power Taos I Y,/2,1, and 2W 400 to 4000 Hz and 200 to 10000 Hz, General Signaling = 125 to 12 kHz Frequency Response respectively. Strobe Specifications Typical Operating Voltage Range 23 - 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate 1 Hz IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) UTP, unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 ft (3048 m) Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Note: Speakers are for connection to compatible fire alarm audio circuits only. S49 Series Speaker Datasheet Reference Model Data Sheet Reference Wall Mount Speaker Only Appliance S49SOW-0001 Wall Mount Speaker Visible Appliance S49SVW-0001 Ceiling Mount Speaker Only Appliance S49SOC-0001 Ceiling Mount Speaker Visible Appliance S49SVC-0001 S49SWC-0001-1 11/2015 TYCO, SIMPLEX, and the produc: names lived in this mat trial are marks and/or reg;stered marks. Ur-czthorized use is s1rict!yprohiksiec NFPA 72 a.c'Nctonal Fire Alarm and Signaling Code are registered tradema1ts c7 he Natonal Fire Prenection Associatior (WFPA). U . Simplex Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S49SWC-0001-1 11/2015 www.sh77pIex-fire.co , 0 2015 Tyco Fire Protection Products. Ad tigls's reserved All spec//cerions and other info -motion shown we-e current as of documenr revis;on date and a-c subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL MMA FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models: 495V-APPLC,49HFV-APPLC,495V-APPLC-BA,49HFV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA,49SVH-APPLC,49H FVH-APPLC,49SV-CWF,49HFV-CWF,495VH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 495V-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF, 49HFV-WRF, *49svAppLw0 *49SvAppLW0.BA *49SVAPPLWCO True Alert ES, Addressable wall mounted Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor and outdoor use. Refer to listee's Installation Instruction Manual for details. *Revision 04-17-2018 dcc TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Contractor's License Detail for License # 986047 DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. CSLB complaint disclosure is restricted by law (B&P 7124.6) If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. Per B&P 7071.17 , only construction related civil judgments reported to the CSLB are disclosed. Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. Business Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2019 License Status This license is current and active. ll information below should be reviewed. Classifications dO - ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR Bonding Information Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond of Qualifying Individual This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for TIMOTHY PAUL ROSTEN in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 Workers' Compensation IThis license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC310893 Effective Date: 10/01/2017 Expire Date: 10/01/2018 Workers Compensation History Other Personnel listed on this license (current or disassociated) are listed on other licenses.