Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2525 EL CAMINO REAL; 253; FPC2018-0334; Permit
CARLSBAD, CA 92008-1265 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Print Date: 02/17/2022 Job Address: 2525 EL CAMINO REAL, # 253, Permit Type: FIRE-Construction Commercial Parcel #: 1563022700 Valuation: $115,000.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Permit No: FPC2018-0334 Status: Closed - Finaled Applied: 10/05/2018 Issued: 10/24/2018 Finaled Close Out: 02/17/2021 Inspector: Final Inspection: PERMIT REPORT (iity of Carlsbad Project Title: Description: KAY JEWELERS -SPRINKLER TI (24 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A jITAN FIRE PROTECTION ~f?:120 g- b4- Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 18600 Kay Jewelers - Store #1374 The Shoppes at Carlsbad 2525 El Camino Real, Suite 253 Carlsbad, CA 92008 ZURN Model 350DA EXISTING WILKINS Double Check Detector Assembly Application 1 Designed for installation on water lines in fire protection systems I MMUNS to protect against both backsiphonage and backpressure of LAEAD FREE polluted water into the potable water supply. Model 350DA shall provide protection where a potential health hazard does .• not exist. Incorporates metered by-pass to detect leaks and . 1*01k. unauthorized water use. 'I, NSF/ANSI 61 Standards Compliance (Sizes 2 1/2 - 10" Horiz. & Vert.) (12 Horizontal Only) ASSE® Listed 1048 (Sizes 2 1/2 thru 12) CSA® Certified 1364.5 (Sizes 2 1/2' thru 8', & 12") AWWA Compliant C510 (Sizes 2 1/2' thru 12"), and C550 UL® Classified (Sizes 2 1/2" thru 12") C-UL® Classified (Sizes 2 1/2" thru 12") FM® Approved (Sizes 2 1/2" thru 10") NYC MEA 147-99-M Vol 4(2-1/2" - 10) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Sizes 2 1/2" thru 12") Meets the requirements of NSF/ANSI 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backflow Assembly 3/4" Model 950XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Springs Stainless Steel, 300 Series Features Sizes: 2 1/2", 3", 4", 6", 8", 10", 12" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI B16.1 Class 125 Dimensions & Weights (do not include pkg.) Options (Suffixes can be combined) O - with OS & Y gate valves (standard) O L - less shut-off valves (flanged body connections) O LM - less water meter - with remote reading meter - with gallon meter (standard) 0 CFM - with cu ft meter O CMM - with cu meter meter O G - with groove end gate valves FG - with flanged inlet connection and grooved outlet connection Ej P1 - with Post Indicator Gate Valve i:i GF - with flanged inlet connection and grooved outlet connection O BG - with grooved end butterfly valves with integral monitor switches (2 1/2* - 10") 0 -509 - with AWWA C509 gate valves Accessories Repair kit (rubber only) 9 Thermal expansion tank (Model XT) 0 OS & Y Gate valve tamper switch (OSY-40) Attention: Model 350DA (flange body) and Mode! 350ADA (grooved body) have different lay lengths. DIMENSION (appmximate) WEIGHT MODEL A B LESS E E E LESS OS&Y OS&Y BUTTERFLY 350DA A WITH GATE C D OS&Y OS&Y WITH F SHUTOFF GATE GATE VALVES SIZE BUTTERFLY VALVES OPEN CLOSED BUTTERFLY VALVES VALVES VALVES GROOVED VALVES VALVES FLANGED GROOVED in. mm in. I mm in. I mm in. I mm in. I mm in. mm in. I mm in. mm in. mm in. ImmIbs.kgIbs. I kg bsIbsj 2112 65 31 787 28 711 157/81403 33/4195 9 229 173/4 451 153/8 391 8114 210 31/2189 68 31 178 81 140 64 3 80 32 32827247/8 40333M959229201I4514174328V221631/2 89 311989815012054 403789563298351249S41/21 9229221/2572ThV446492296152106 48 296t34282 086 6 616 717818082480218454298 160P 2O6 135 8 200603/41543537/81369373/4959 10 254 12 30537 940 281/2 724 12 305 81/2 216 374 170 850 386 802 548 249 10 250633/41619577/81470373/4959 10 254 12 305455/81159343/4 883 13 330 81/2 216 404 183 1222 554 1156 792 359 12 30O66V4 83 n/a 965 10254 12305 53134640 21029 n/a n/a 87/8226463 210 Th23736 n/a n/a n/a Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. H Date: 1/17 Document No. BF-350DA Patent No. 5, 913, 331 Product No. Model 350DA Page 1 of 2 VERTICAL INSTALLATION Flow Characteristics MODEL 350DA2 1/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (Vs) 0.0 12.6 25.2 37.9 0 Rated flow (established by appmval agencies) 0' 0 50.5 103 En to 69 h... (0 -34cc n 200 400 600 FLOW RATES (GPM) MODEL 350DA 6" & 8" (STANDARD & METRIC) FLOW RATES (us) 31.5 63.1 94.6 126.2 0 500 1000 FLOW RATES (GPM) 1500 2000 MODEL 350DA 10" & 12" (STANDARD & METRIC) FLOW RATES (us) 0.0 31.5 63.1 94.6 126.2 157.7 189.3 220.8 0 500 1000 1500 2000 2500 3000 3500 FLOW RATES (GPM) 800 157.7 103 to 8 1" (200mm) 69 34 Co to Lu 2500 252.4 283.9 103 0) rim) I 8 1 69 1"EEEI1 4 F 4000 4500 0.0 Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 (305mm) and a maximum of 30' (762mm) above adequate drains with sufficient side clearance for test- ing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 3' 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 ____ 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 OUTDOOR INSTALLATION Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NorylTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 350DA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 FireLock® V38, K56 Models V3801, V3802 \/tauIic 40.50 Adjustable Concealed Standard Spray Standard and Quick Response Technical Specifications: Models: V3801, V3802 V3801 and V3802 Approvals/Listings: ® <g> CE ILPCBI LISTED 0832 104-la/02 See Victaulic Publication 10.01 for more details. Product Description: This concealed, designer style sprinkler allows up to 1/2713 mm adjustment to accommodate concealment needs. The "standard" design provides a consistent hemispherical spray pattern. The separate two-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. Coverage: For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. Style: Adjustable concealed, ordinary hazard, light hazard Nominal Orifice Size: /2713 mm K-Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: 1/2 /15 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3. 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. 'Jill' JiP(. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 40.50 2558 Rev. 0 updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 ictaulic V I victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Material Specifications: Accessories: Deflector: Bronze per UNS C22000 Installation Wrench: Cover Plate: Fusible solder 11 Concealed: V38-4 or V38-5 Bulb: Glass with glycerin solution. Bulb Nominal Diameter: LI Standard: 5,0 mm LI Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Stainless steel per UNS S30100 Seal: Teflon2 tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene Sprinkler Finishes: LI Plain Brass (only) Cover Finishes: LI Chrome Plated LI White Painted3 LI Flat Black Painted3 LI Custom Painted3 2 Teflon is a registered trademark of Dupont Co. DL Listed for corrosion resistance. 40.50 2558 Rev. o updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 4tauIicr victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Approval/Listings- Approvals/Listings Model V3801 V3802 Orifice Size (inches) /2" 1/2" Orifice Size (mm) 13 13 Nominal K Factor Imperial 5.6 5.6 Nominal K Factor S.l. 8.1 8.1 Response Standard 5mm bulb Quick4 3mm bulb Defiectorlype Concealed Pendent Concealed Pendent Adjustment Approved Temperature Ratings F°/C° V3801 V3802 135 F/57 C 135 Ff57 C 155 Ff68 C 155 Ff68 C cULus 175 Ff79 C 175 Ff79 C 200 F/93 C 200 Ff93 C 155 Ff68 C4 FM5 NONE 175 Ff79 C4 200 Ff93 C4 135 Ff57 C 135 Ff57 C NYC/MEA5 #62-99-E 155 Ff68 C 155 Ff68 C 175 Ff79 C 175 Ff79 C 200 Ff93 C 200 Ff93 C 135 Ff57 C 135 F/57 ,C CSFM5 #7690-0531:112 155 Ff68 C 155 Ff68 C 175 F/79 C 175 Ff79 C 200 Ff93 C 200 Ff93 C 155°Ff68C Sprinkler/i 38°Ff59C Cover 155Ff68°C Sprinklerfi 38°Ff59°C Cover LPCB 175°F/79°C Sprinkler/165°F/74°C Cover 175°Ff79C Sprinkler/1 65Ff74°C Cover 200°F/93°C Sprinklerf165°Ff74°C Cover 200°Ff93°C Sprinkler/1 65°Ff74C Cover 135 Ff57 C 135 Ff57 C 155Ff68C 155Ff68C VNllPO 175 F/79 C 175 F/79 C 200 F/93 C 200 Ff93 C 286 Ff141 C 286 Ff141 C CCCf ZSTDY NONE 155 Ff68 C For K-Factor when pressure is measured in Bar, multiply S.I. units by 100. Recognized by FM as standard response only. Note: Listings and Approvals as of printing. All are approved open. 40.50 2558 Rev. 0 updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 3 \,4tauIic victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Dimensions: Models V3801, V3802 (drawings not to scale) 25/68 mm Max Rule 2W/SO mm I in. Hole 2Y6759 mm I lbl~~ pical Ceiling Tile Finished Surface "M Minimum Extension 2'3Wfl1 mm ½"/13 mm Adjustment 3M6780 MM 3W/83 mm Conet Plate Maximum Extension 2/5t mm 11 Typical Ceiling Tile Finished Surface Distribution Patterns: Models V3801, V3802 K5.6 standard concealed pendent distribution patterns - trajectory ua.aum'u'.i NONE mom ON iiiiuiauii 0 I NENNEN IIIUUUNRUUU NOMENON mom iuiauiasiiauu UIIUIISIRkI OMEN 2' 4' 6 8' 10 12' 14' 0.6 m 1.2 m 1.8 m 2.4 m 3.0 m 3.7 m 4.3 m 7psi ___.. 15 psi 30 psi 48 kPa 103 kPa 207 kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. 40.50 2558 Rev. 0 Updated 07/2014 tE 2014 Victaulic company. All rights reserved. victaulic.com 4 \/taLJIiC 10' 3.0 m 8' 2.4 m 6 1.8 m 4, 1.2m 2' 0.6 m 0 victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Ratings: All glass bulbs are rated for temperatures from -67°FI-55°C to those shown in table below. Sprinkler Sprinkler - V3801, V3802 Cover - V38 Temperature - F! C Temperature - F/ C Nominal Maximum Ambient Nominal Maximum Ambient Temperature Victaulic Part Temperature Temperature Victaulic Part Temperature Temperature Classification Identification Rating Allowed Glass Bulb Color Identification Rating Allowed Ordinary A 135 Ff57 C 100 Ff38 C Orange A8 1351 57 100 57 Ordinary C 155 Ff68 C 100 Ff38 C Red D 7 165 74 150 65 Intermediate E 175 Ff79 C 150 Ff65 C Yellow Intermediate F 200 Ff93 C 150 F/65 C Green High J 286 Ff141 C 225 Ff107 C Blue Extra High K 360 F/182 C 300 Ff149 C Purple - M Open - No Bulb 6 A For use with Standard or Quick Response Concealed Sprinkler 135°F157°C or 155°F/68°C. D For use with Standard or Quick Response Concealed Sprinkler 175°F/79°C or 20UF/93°C. 8 138°F159°C per LPCB Note: Custom Finish - Customer to provide paint specification, allow 4 - 6 weeks for samples. Available Wrenches: Sprinkler Type Recessed Concealed Pendent - V3801 V3802 V38-4 or V38-5 40.50 2558 Rev. 0 Updated 07/2014 (D 2014 Victaulic Company. All rights reserved. victaulic.com 5 \J(tauIic victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 - àWARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. - Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For O minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: ME 001-610-559-3300. Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data, and are available in POF format Victaulic reserves the right to change product specifications, designs and standard on our website at www.victaolic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and Zero-Flea are registered trademarks of Victaulic Company. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 6 \)4CtaUIic FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to !4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. \4taUIic 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: '/2/13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ N PT/iS mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 02014 victaulic company. All rights reserved. 1 ictaulic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: F-1 Standard: 5.0 mm LII Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: LI Open End: V27 LI Recessed: V27-2 Sprinkler Finishes: LI Plain Brass LI Chrome plated LI White painted3 LI Black painted3 LI Custom painted3 LI Proprietary Nickel Teflon2 coating3 LI VC-2504 155, 200, 286 SR Only: LI Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. i updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 2 '%jtaUIiC victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model ____________ ____________ APPROVALS/LISTING S V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 1 8.1 1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°IC° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286" F/141 °C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135"F/57°C FM 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200" F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175" F/79°C 286° F/i 41°C 286°F/141°C 200°F/93°C 286°F/141°C 286'F/141'C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C NYC/MEA 62-99-E 175" F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286" F/141 °C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93°C 360°F/1 82°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141 °C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360'F/1 82'C 360°F/1 82°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 135°F/57°C 155°F/68°C 155°F/68°C VdS 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/1 82°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286° F/i 41°C 286°F/141°C 360°F/182°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 \J'tauIic 37 mm 2 60 2W! 41 mm 60 mm victaulic.com I Sprinklers FireLock® I K5.6, V27 I Publication 40.10 Dimensions: Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 P 23x iso mm Max. Hole 2/Simm Mm. Hole 30 rnnn 17 rnm Finished Surface 30 43 mm QO Typical Ceiling Tile _ MAXIMUM RECESS - 2Xx/ - 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) axjxx mm Max. Hole Min. Hole ng 24 Finished tsurface J 2'5A6"/ MAXIMUM RECESS - 2Nx/ 75 mm MAXIMUM EXTENSION 3/4 Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. i Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 jtauIic Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns - Trajectory 10 3.0n 2.4m 4, 1.2m 2' 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: 2' 4' 6' 8' 10' 12' 14' 1.2m i8n 2.4n 3.0n 3.7m 4.3m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory iuiii•iuiui• uuuuuuuuiu• i•aiiiiiiii IIu.u.IluuIII 2' 4' 6 8' 10' 12' 14' 16' 0.6n 1.2m l.8m 2.4m 3am 3.7m 4.3m 4.9m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 5 \J1tauIic 10. 8' 2.4m 6 lam 4, 1.2m 2' 0.6m 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 F138 C Orange Ordinary C 155 F/68 C 100 F/38 C Red Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F8/107 C Blue Extra High 7 K 360 F/182 C 300 F1149 C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. Available Wrenches: V27-2 Recessed V27 Open End V2707, V2708 Pendent V2707,V2708 Recessed Pendent V2703, V2704 Upright WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. OWN Installation Note Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Sheet for the product you are installing. This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and is available in POF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 6 ,4tauIicr Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards, All products are stencilled to meet FM & UL specifications. c®us LISTED APPROVBI J4ONFSA NFPA' 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE SIZE (IN) O.D. (IN) I.D. (IN) CRR** WEIGHT/FT WATER FILLED WEIGHT BUNDLE SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 11/4 1.660 1.442 991 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 ' 2.375 2.157 ' 6.27 2.64 lbs/ft 4.223 37 2:1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.341bs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/fl WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.271bs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2,067 100 3661bs/ft 5.114 30 2-1/2* 2.875 2.468 1.00 580 lbs/ft 7.875 30 3* 3500 3.068 100 758 lbs/ft r 16.783 ' 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 'Only available in Casa Grande, AZ "Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 CIa/taos Road Chesterfield, MO Gerald, MO Kent. WA Casa GrasdAZ Dallas, TX Masurr OH 63017 Dull Moose Tube's0 Eddythread 40® ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 40® I) is a lightweight replacement for Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion Has a pressure rating of 300 psi. Resistance Ratio of 1. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers tower freight costs. Supplied with EDDY GUARD 110 MIC preventative coating. EODYTHREAD 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB/FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 corrosion Resistance Ratio per latest UL Directory listing c®us LISTED PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROVOI i] AQcA_ NFPA' I)A For Additional Information Contact (800) 325-4467 www.bulImoosetube.com c) Or From Canada Call: (800) 882-4666 sales@bullmoosetube,com 1819 Clarkoon Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, TX Masurr OH 63017 5 Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APPROVU [;;] 4qNi4 NFPA' 6 ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM A135 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 11/4 1.660 1.482 008 479 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 016 431 2.617 4.230 37 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. A For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800).882-4666 sales@bulImoosetube.com U 1819 clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grand AZ Dallas, TX Masurx OH 63017 c®us LISTED no 4COMM NFPX ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD Il® MlC preventative coating. NPS O.D. EDDY FLOW® EDDY FLOW WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER FT. WI. SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 1-1/2 1.900 1.728 344 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 : 11.290 19 .Corrosion Resistance Ratio per latest UI Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c) A For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Case Grand AZ Dallas, TX Masuix OH 63017 '4 Bull Moose Tube's® Eddy Flow® is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's® larger ID provides an opportunity for downsizing and further cost savings. Dull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® U a versatile product that can be Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. 'With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDYm WEIGHT WATER BUNDLE (IN) (IN) EDDY' (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 111 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 Pressfit is Registered Trademark of Victaulic company of America Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED APPROVOI i:; A1\f NFPA —c-- 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q ® For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas, X Masory. OH 63017 NPS(N) 1 1-114 1-112 2 2-1/2 3 4 c®us LISTED 0.0(i) 1.315 1.660 1.900 2.375 LD.(in) 1.201 1.546 1.786 2.261 ULTRA EDDY Empty Weight (lb/ft) 0.868 1.107 1.274 1.604 Pater-filled Weight Ob/ft) 1.359 1.920 2.360 3.344 rcnR. 2.17 1.40 iii 1.00 00 (in) 1.660 1.900 2.375 2.875 3.500 4.500 10(m) 1530 1.728 2.203 2705 3.334 - 4.310 { Empty Weight (lb/fl) 1.222 1.844-- 2.330- 2.809 3.361 4.968 EDDY FLOW WaterFlfledWeightOb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. - 1.98 3.44 2.78 1.66 1.00 1.00 r OD (in) -1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE r10 Emptyweig-hit(mb'ft) 1410 1810 2090 2640 3530 4340 5.620 Water-FifledWeightOb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 1527 991 776 627 492 354 250 0D( In) 1.315 1.660 j.900 2.375 1137 1.482 1.712 2,177 EDDYLITE [ -Empty Weight 1.260 1617 1.90 2.617 Water HOed Weight (lb/It) 1 700 2 364 2.965 4.230 CR9. 0.13 •. 0.08 0.12 . 0.16 00 (in) 1.295 1.650 1.900 2.375 W.D.(in) 1.083 1.418 1.645 2.123 EDDYTHREAD Empty WeightOb/fl) 1.461 2.070 2.547 3.308 40 Water-Hlled Weight (lb/ft) 1.860 2.754 3.468 4.842 rr1 1.00 1.00 1.00 1.00 OD. (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 - ID (in) 1.049 1.380 1.610 2067 2.469 3068 4026 SCHEDULE jEmptyWeightlb/ftj 1.680 2270 2.720 3.660 5.800 7.580 10.800 40 WaterHlled Weight (lb/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 Jr CRR 100 100 - 100 100 100 100 100 Q For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA (ate Grande. AZ Dallas, TX Masury, OH 63017 9 APPR0VHt m A-.,:: i ~ q ~ NFPA c®us LISTED APPROYRI (; 4.omm NFPA' 10 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY0 0.868 91 1,659 1,896 1,975 SCUEDULE10 1.410 91 - 2,695 3,079 3,208 1 EDDYLITEO 1.260 91 2,408 2,752 2,867 rEDDyTHREAD4on 1.461 70 2,148 2,454 2,557 SCHEDULE 40 1.680 70 2,470 2,822 2,940 U1TP4EDDYn 1.107 61 1,418 1,621 1,688 EDDYFLOW 1222 61 1565 1,789 1,864 1114 SCHEDULE10 1.810 61 2,319 2,650 2,760 - EDDYLITE' 1.617 61 2,071 2,367 2,466 EDDYTHREAD46 2.070 51 2,217 2,534 2,639 - SCHEDuiE40 2:270 51 2;431 2,778 2,894 ULTRA EDDY' 1.274 61 , 1,632 1,865 1,943 EDDY FLOW 1.844 61 2,362 2.700 2,812 SCHEDULE 10 2.090 61 2,677 3.060 3,187 1-1(2 EDDYLITE 1.967 61 2,520 2,880 3,000 EDDYThREAD 4-Oi 2.547 44 2,353 2,690 2,802 SCHEDULE 4O' 2.720 44 2,513 2,872 2,992 - ULTR.AEDDY 1.604 - 37 -- 1,246 - 1,424 1,484 EDDYFLOW' 2.330 37 1810 2,069 2155 SCHEDULE1O 2.640 37 ' 2,051 2,344 2,442 2 EDDYLITE':. 2.617 37 2.033 2,324 2,421 [E66YTHREAD 40 1 3.308 30 2,084 2,382 2,481 [ SCHEDULE 40 3.660 30 2,306 2,635 2,745 [EDDYFLOWn1 2.809 1,770 2,022 2,107 2-1/2 [ SCHEDULE 10 3.530 30 2,224 2,542 2,648 - SCHEDULE4O 5.800 3,654 4,176 4,350 r-- DI~Y FLOWO, 3.361 1 341 1,533 1,596 3 HED [SCULE1O 4340 19 , 1732 1,979 2,062 L - SCHEDULE 40 7.-580 - 3,024 3,456 3,601 EDDY FLOWS 4.968 1,982 2,265 2,360 4 [scHEDuLE io, 5.620 19 2,242 2,563 2,670 L....._ SCHEDULE 40* 10.800 4.309 4,925 5,130 - SCHEDULE 10 9.289 10 1,951 2,229 2,322 8 16.940 7 2,490 2,846 2,965 Only Available in Casa Grande, AZ. Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing' Size 20 ft. F25ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 136 1 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1 1012 1 867 1 7261 40 1 40 1 40 1 40 1 40 37 34 1 32 1 30 1 29 1 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 BC (ASCE 7-05 ) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 1 40 40 40 35 31 28 26 25 23 22 21 20 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 J11/2 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED NFPX -.'- For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com J 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ DallasjX Masray, OH 63017 11 MechanicaIT® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical-T Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade °E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+820C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect- Para__________ Location Date________ Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 vICTAuuc COMPANY. ALL RIGHTS RESERVED. REV_N 4t2aUIicr 11.02_i DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1h"I50 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size No. Pressure@ Dimensions Weight Each Qm UL ML I1 I,, - - 2 1/2 (a) a 50 15 920N 500 3450 1381 1.50 1 200 2.53 64 - 1.61 41 I 5.35 2.75 70 3,1 5 - 1/4 (a) n 920N 500 l 1.50 1.97 2.53 1.61 I 5.35 2.75 3.1 20 a 3450 381 50 64 - 41 136 I 70 1.5 - 1(a) 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 - 500 2.05 2.75 11/4 (a) to 1.75 3.00 1.61 I 5.35 3.00 3.5 3.2 32 920N 3450 j 44.5 52 70 76 41 J 136 76 1.7 1.5 1½ (a) to 920N 500 1,75 2.03 2.75 3.12 1.61 I 5.35 3.25 3.6 3.2 40 920N 3450 , 44.5 1.50 52 2.21 70 2.74 79 41 1.82 136 5.64 83 1.7 3.0 1.5 2½ ½ (a) §0 500 2.75 65 15 J! .L.._19_ 46 143 70 1.4 ~ (a) §a 920N 1.50 2.18 2.74 1.82 5,64 2.75 .. 3.0 500 I 20 3450 38.1 55 46 143 70 1.4 1.82 5.64 2.75 1(a) §0 920N 500 1.50 2.06 2.74 2.9 25 3450 38.1 52 70 - 46 143 j 70 1.4 - 3.25 1.82 6.29 J 3.00 11/4 1(a) a 920N 500 1.75 2.30 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 500 I 1½ 1(a) a 920N 2.00 I 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 2.25 151 6.46 83 3.18 1J 3.9 6 76.1 1h (a) 920 N 300 1.50 2.22 2.75 15 2065 38.1 56 70 - 57 164 81 1.8 - IK 920N 300 1.50 2.75 2.25 6.46 3.18 3.9 2.19 20 1 2065 ,j 38.1 56 70 - 57 164 81 1.8 1 (a) 920N 1.50 2.07 2.75 2.25 6.46 3.18 3.8 300 25 2065 38.1 53 70 - 57 164 81 1.7 - 500 3.00 1 ¼ (a) a 920N 1.75 2.30 3.00 3.31 1.92 j 6.29 3.5 3.2 32 3450 j 44.5 58 76 84 49 160 76 1.6 1.5 500 11/2 (a) a 2.00 2.28 3.00 3.31 1.92 6.29 3.25 I ,s 3.3 40 920N 3450 500 50.8 1.50 58 2.52 76 3.05 84 49 2.28 160 1 6.15 83 2.75 1.6 3.4 1.5 3 ½ (a) a x 80 15 3450 38.1 64 78 - 58 156 70 1.6 - 'A (a) a 500 1.50 2.49 3.05 1 2.28 6.15 2.75 3.4 20 3450 381 63 78 - 58 156 70 1.6 - - 500 3450 1(a) 25 920N 1.50 ,j1 I 2.38 3.06 78 - 2.28 58 6,15 156 2.75 70 3.3 1.6 - 11/4 (a) to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) - 34SOj445 65 83 90 58 156 76 1.8 1.8 1112 (a) to 920N 500 2.00 2.78 1 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 ' 1.9 1.8 2 (a) a 92014 500 1 2.50 2,75 3.50 3.56 2.28 6.75 4.9 4.6 3.88 50 3450 63.5 70 89 90 58 2.44 172 6.72 99 3.88 2.3 2.1 3½ 2 500 2.50 3.00 3.75 3.8 90 50 92014 3450 63.5 76 1 - 95 1 62 171 1 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 1 Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.viCtaulic.Com _JItaUIic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIc COMPANY. ALL RIGHTS RESERVED. 11.02_2 REV_N DIMENSIONS Y -11:11 r-r- z oif GROOVED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psiI3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½"/50 x 15 mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. FEMALE THREADED OUTLET CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Style Max. lorl IMfl ch M I am Q90 1 I IS TABLE CONTINUED FROM PAGE 2 4 ½ (a) 920N 500 1.50 3.03 I 3.56 2.69 7.01 2.75 3.7 100 15 j 3450 38.1 77 90 - 68 178 70 1.8 - 14(a) C 920N 500 j 1.50 3.00 3.56 2.69 7.01 2.75 3.7 22 j3450l38.1 _7690 -68 178 70 L! 1 (a) a 92014 500 1' 1.50 2.88 1 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 L 90 .I68 178 70 1.8ii. 500 1/4 (a) to 92014 1.75 ) 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 + 4' 78 96 102 68 178 76 1.9 1.8 11/2 (a) to 920N 3.28 4.00 4.00 2.69 7.01 4.2 3.9 500 2.00 3.25 1. 83 _ _2 _2_ 2.50 3.25 4.6 2(a) to 92014 500 j 4.00 4.00 2.69 7.01 3.88 5.0 50 --3450 63.5 I 83 102 102 2! I78.99 2.3 2.1 21/2 (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 4 2.6 2.3 761 mm 920 500 ) 2.75 2 .88 - 4.00 2.69 1 7.34 4.63 6.4 _______ 3450 69.9 73 J 102 68 j 186 118 2.9 3 (a) t 920 500 3.31 'T 4.50 2.69 7.73 5.12 8.4 6.4 3.50 4.12 80 3450 1 88.9 84 1 114 105 68 196 130 3.8 2.9 1080 < 11/4(a)a 920N - - - + - 2.63 7.64 - 3.05 . - 5.0 - 1 500 - 1.75 -1----- 3.08 t 1 3.78 32 3450 443 78 96 - 67 +194 28 1 2! 11/2 (a)a 920N 2.00 4.00 1 - 2.63 7.64 3.25 1 5.0 500 3.28 40 3450 50.8 83 102 67 194 83 2.3 - 500 ,3450 2(a) _2_ 920N 2.50 63.5 3,25 !L..LJ9 4.00 11 2.63 7.64 4.00 4.0 2! 500 761 mm 3450 920 2.75 2.88 4.00 1 4.00 2.63 7.64 4.29 8.0 7.8 69.9 102 102 67 194 109 3.6 3.5 3(a) 920 500 3.50 I 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 920 3450 500 88.9 j_ 2.00 84 1 4.03 114 4.75 114 4.75 67 194 3.16 9.70 124 3.69 3.1 7.4 3.0 7.6 5 1112 (a) 125 >< 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) t 920 500 2.50 I 4.00 4.75 4.75 3.16 1 9.70 4.38 8.2 8.0 50 121 121 80 j 246 ..L .2! .3.6 _ 21h (a)t 920 500 I 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 1 69.9 92L i 121 246 .80 118 3.8 3.6 76.1 mm a 920 2.75 69.9 . 3.75 - i 4.75 ii. 3.16 9.70 80 246 . 4.63 !i!. - . I. 500 3450, 8.0 ! 500 3(a) t 920 3.50 1 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 497 2.50 3.75 ' 127 4.50 Ill 2! + 246 3.17 135 3.88 8.0 2! .1 4.0... 2 500 1330 x 50 92014 3450 ..L L_2_.J1!.1 ii ..2L - q203 920 500 3.50 3.81 5.00 3.00 .5.31 8.0 80 3450 88.9 97 127 - 76 240 1 135 3.6 - TABLE CONTINUED ON PG. 4 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/5' BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in china by Tianjin Approvals Company. www.victaulic.com vlclAuLlC IS A REGISTERED TRADEMARK OF vICTAuLIC COMPANY. 0 2017 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_N jtauIict 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Y z GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2 /50 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Size Style No. ~Pre~ssure@~ Ma Work i:r.ns II Gib - TABLE CONTINUED FROM PAGE 3 1 1h '1' 139.7 x 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 114 - 84 209 83 3.2 - 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 920N 3450 500 63.5 1.75 95 4.43 114 5.13 - 5.13 84 j, 3,79 209 9.15 99 I 3.25 4.1 5.1 - 4.8 6 1¼ (a) 150 32(b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 5.13 1½ (a) '' 920N 500 2.00 4.40 5.13 3,79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) tit 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 j, 3450 63.5 111 130 130 96 232 99 2.7 2.5 920 500 2.75 2½ 4.01 5.13 5.12 3.69 10.51 4.63 83 7,6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 500 10.51 76.1 mm 1, 920 2.75 4,15 - 5.21 3.69 4.63 - 8.4 3450 69.9 105 132 94 267 118 3.8 500 8.4 920 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a) to 920 500 4.50 3.1 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 20N 3450 114.3 97 4.41 146 5.13 137 94 3.63 267 9.40 159 3.25 4.6 7.8 4.6 1 ½ (a) 159.0 x 500 2.00 40 3450 50.8 112 130 - 92 239 83 3.5 - 2 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 - 92 239 99 3.6 - 2.75 76.1 mm 920 500 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 3.50 3 20 500 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 92 239 155 - 4.5 18.0 920 500 4.50 3.81 5.75 3.63 9.40 6.25 100 3450 114.3 96.80 146 - 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ictaulie vICTAuuc IS A REGISTERED TRADEMARK OF VITAUC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 REV,N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Y z -, wil GROOVED OUTLET loop Iis sI$ FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 47200 x 100 mm k IlIalW,I.1D1d. Approx. Weight H ~Isl 'II Th TABLE CONTINUED FROM PAGE 4 1 165.1 x 25 92oN 500 1.50 3.88 .1. .2 4.56 116. - 3.79 9.34 .26.. .?. 2.75 70 8.0 16 - 114 a 92 N 500 1.75 j 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 500 44.5 2.00 113 4.41 130 5.13 5.13 2. 237 3.79 1 3.25 1 3.8 8.4 5.4 11/2 (a) to 40 20N !.Q 50,8 4_.130 112 1' 130 96 237 83 3.8 2A 2 (a) t 20N 500 2,50 4.38 5.13 5.13 3,79 9.34 I 3.88 8.5 6.0 50 3450 63.5 j, 111 130 130 96 237 ,99 3.9 2.7 761 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 8.6 7.6 4.63 I _____ - 29. 69.9.. I 119_ 130 .12 .92 i .Z I LJL 3.4 500 3.50 5.31 3 (a) ' 0 920 4.31 550 5.13 3.63 10.51 10.2 8.4 80 3450 J 889j flU 1 WU 130 92 267 135 4.6 500 4.50 4 (a) to 920 3.81 5.75 5.38 3.63 10.51 6.25 10.5 I 8.4 100 3450 114.3 t 97 146 137 92 267 159 4.8 3.8 t 8 2(a) t 92 0 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 500 2.75 2112 (a) t 2 920 5.07 6.19 6.19 4.81 12.42 1 4.50 I 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 J, 5.3 2.75 4.56 6.1rnma 920 500 J 5.25 6.25 4.81 12.42 11.6 3450 69.9 133 - 159 122 316 116 5.3 500 1 6.50 ' 3(a) to 920 3.50 5.31 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 -.... 135 165 165 122 316 1 135 5.7 5.3 500 4.50 ''•1' 4.81 6.75 6.38 4(a) ta 920 4.81 12.42 -t ---.t.- 6.25 - 15.3 12.5 100 3450 114.3 122 171 162 122 316 I 159 6.9 I 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China byTianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.vuCtaulic.com vICTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_N j?;;tUijC• 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA © JIT Exaggerated for clarity Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C,K, Values: AP = Where: Q= Flow (GPM) AP = Pressure Drop (psi) Q = C x I/Ap C = Flow Coefficient AP = Q2 Where: 0 = Flow (m3/hr) V AP = Pressure Drop (Bar) Q = K x Jz KV = Flow Coefficient Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe OUTLET SIZE (C 120)t FT C,/K, Values I1EH!1I , 1! 11 ½ 0.840 11 15 21.3 1.050 - 2 - 9.4 16 ~ 20 1.315 .,., __.. ....._. . .__._.__.... 21 1 3 8 25 I 337 1.660 - 50 1.8 48 1/4 32 42.7 1.900 1 55/ 11 6 11 42.9 53 41.1 53 1 ½ 40 98.3 2.375 45.4 112 45.4 104 2 50 60.3 1 2.875 9 101/5 96 119 89.1 150 2½ 65 73.0 3.000 20 16 12½ 102 I 161 128.5 76.1 mm 76.1 3.500 - 138.1 249 - 237 3 80 88.9 4.500 14 15½ I 213.4 421 203.1 401 4 100 114.3 20 22 360.8 343.6 Hazen-Williams coefficient of friction is 120. * Pipe with a wall thickness of 0.165ini4.2mm. 1 FireLock" Innovative Groove System (IGS) outlet www.victaulic.com VICTAuLIC IS A REGISTERED TRADEMARK OF VlCTAC COMPANY. 02017 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. XACtsulia 11.02_6 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical—I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 17177.11 Approval :Pressures ffJ Agency am= 21/2 -6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 7i0-3 j 2755 300 i 2755 2755 99 t 99 2496 21/2 -4 2.875 - 4.500 All DF 300 300 290 232 362 65-100 73.0-114.3 SF 2065 300 - 2065 300 2065 300 1999 290 1599 232 2496 362 21/2-4 2.875 - 4.500 All 65-100 4!i. 6.625 . . 1 4 300 300 250 L1999 - 290 - 232 2496 362 6 150 168.3 6.625 34 -. 30 40 2065 --_ 300 2065 - - 300 1724 ----.- 300 1999 1 ..........- 290 1599 232 2496 362 6 150 168.3 1-0,40 2065 400 2065 - 2065 _ 1999 -1199 145 2496 8 8.625 21/2 200 219.1 8.625 1 34 10 2755 300 - - 250 - 1000 145 - - 8 200 21 8.625 .j 34 '2065 . 3040 300 _ 1724 300 . . - 1000 145 - 8 200 219.1 2065 - 2065 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4- 81100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5/125mm, 6/150mm and 8/200 mm diameter pipe. The Style 931 comes with a 2W/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com vlclAuuc IS A REGISTERED TRADEMARK OF VICTAULIc COMPANY. © 2017 VITAUUC COMPANY. ALL RIGHTS RESERVED. ictaulie REV_N 11.027 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com '%119t,aUIicr 11.02 1480 REV N UPDATED 12/2017 VITALIC 5 A REGISTERED TRADEMARK OF viciuic COMPANY. 02017 VITALIC COMPANY. ALL RIGHTS RESERVED. 11.02.L FireLock® STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals 0: MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date___________________________________ www.victaulic.com VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 vICTAuuC COMPANY. ALL RIGHTS RESERVED. REV_G 4ac—ta-ulid 10.521 FireLock® Outlet-I STYLE 922 DIMENSIONS MEER li;'L-,.I I_I • . uuf IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 ' "IM151IL" j 9- 1 1/4 1/2 1 3/16 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 4 33.0 46.5 27.9 98.3 654 0A5 - - 3/4 1 3/16 1 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1/6 1.52 218 1.10 3.87 2.56 1.2 25 30.2 38.6 1A6 1.42 55.4 1.95 27.9 1.22 98.3 4.08 65.0 2.56 0.54 1.2 1½ 1/2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 1/l6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 356 494 314 1036 65.0 044 1 1/6 I 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 j41.7 1 3A6 1.66 58.4 2.19 1.46 4.60 31.0103.665,0 0.59 2.56 1.3 2 x 1h 50 15 30.2 42.2 55.6 37.1 - 116.8 65.0 0.59 3,4 1 3/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 1 41.7 55.6 37.1 116.8 65.0 0.64 1 1,56 f 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 1 3/16 1.91 64.5 2.44 37.1 1.71 116.8 5.40 65.0 2.56 0.68 1.6 2½ x ½ 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 1,i6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 3A6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 1/6 1.91 70.9 2.44 43.4 1.71 137.2 5.50 654 1 2.56 0.73 1.6 1/2 76.1 mm X 15 30.2 I 48.5 62.0 43.4 139.7 65.0 0.73 r-T44 F2~44 .7, 1.71 3/4 3/4 1 3/16 PA rT89 5.50 2.56 -1.6 20 32 _4&0 62.0 1 139.7 65.0 L~3 1 3/16 I 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1O.52_2 \4taulic' REV_G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-I STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com - VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ictaulic REVG 10.52_3 FireLock® STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV 0 UPDATED 12/2009 ictauIic viciuic IS A REGISTERED TRADEMARK OF ViCTAULIC COMPANY. 0 2009 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings SMITH.-COOPEW INTERNATIONAL Ductile Iron Threaded Fittings rSpecifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP c®Lus Ductile iron castings conform to ASTM A536 LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 < > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 COUS APPROVED Fig. 35E 3_900 Elbow LISTED Size in Part N umber I U A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E3006 1.31 70 140 0.3 -- 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 - 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.67 30 60 _07- 1-112 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 !12x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 - 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x_1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 1! Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 351 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 3513012 1.75 10 20 1.1 1-1/2 3513014 1.94 10 20 1.5 2 3513020 2.25 6 12 2.4 2-1/2 3513024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwwsmithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4 x 1/2 - 35RT3006004 1.20 1.20 1.22 60 120 0.4 lx 1/2 35RT3010004 1.26 1.26 136 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1x3/4 35RT3010006 1.38 1.38 1.45 25 50 ' 0.6 1 x3/4x3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35R13012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35R13012006 1.45 1.45 1.62 15 30 0.9 1-114x 3/4 x1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35R13012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x lxi 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 1.41 1,41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x 1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 i-1/2x3/4x1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x 3/4 x1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-112x1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2xlx1-1/4 35RT3014010012 1,82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35R13014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35RT3014012 1.82 1.82 1.88 12 - 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/435RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x 2 x 1 x 2 35RT3020010 1.73 1.73 2.02 8 16 1.7 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35RT3020012 1.90 1.90 210 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35R13020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 c®US APPROVM Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35BT3006010 1.45 1.45 1.37 30 20 - 60 0.6 1x1-114 35B13010012 1.67 1.67 1.58 40 0.9 1x1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 - 35B13012020 2.10 2.10 1.90 10 20 1 1.6 1-1/2x1-1/4x2 35B13014012020 2.16 2.10 2.02 10 -8 20 1.8 1-1/2x2 35B13014020- 2.16 2.16 2.02 16 1 1.8 SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com 112 Fig. 35CP3 - Straight Coupling with Ribs ceus<~> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 - 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 - 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 1-1/4x3/4 35RC3012006 2.06 40 80 0.6 2x 1 (not hex)l 35RC3020010 2.81 20 40 1.0 Size in Part Number A in Packing Weight lb Inner Master lx 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35H83020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2x1-1/2 35HB3020014 - 1.38 40 80 0.6 Fig. 355P3 - Square Head Plug I I Size in Part Number A in Packing Weight lb Inner Master I 1/2 35SP3004 0.94 600 1200 0.07 I_3/4 35SP3006 1.12 350 700 0.1 I 1 35SP3010 1.25 200 400 -0.1 11-1/4 35SP3012 1.37 100 200 0.3 I 1-1/2 35SP3014 1.44 80 160 0.4 - 2 35SP3020 1.50 45 90 0.6 - 4 D U -. -- - C- 341 Fig. 35RC3 - Hex Reducing Coupling Fig. 35HB3 - Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number _______________ A in Packing Weight lb Inner Master 1 35U3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U3020 3.12 1 6 12 1 2.4 113 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwwsmithcooper.com Size in Part Number A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 - 35X3012 1.75 12 24 1.4 1-1/2 - 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 AL ce us APPROVED Fig. 3513- Cross LISTED Fig. 35RX3 - Reducing Cross I Size I in I ' I Part I A I I . fl I B i I in I Packing I Weight I lb I Inner I Master I 1-1/4x1 I_5Rx3012010 I 1.67 1.58 I 15 30 1.2 I1-1/2 x1 I 35RX3014010 I 1.80 I 1.65 I 12 i 24 I 1.4 2 x 1 35RX3020010 F 2.02 J 1.73 8 16 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C3012 1.28 70 140 _0A 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 - -0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Begin Clamp I Size in I Part Number I I A . I in I_PackingI Weight I I lb I Master I_3/8 I 35BC3003 I 0.75 i_InnerI_ 100 200 I 0.3 I I 1/2 I_35BC3004 I_0.75 I 80 I 160 I 0.5 SMITH-COOPER INTERNATIONALA • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com 114 INSTALLATION STEPS - !i I INTO WOOD & STEEL: FSTALLATION STEPS -I®1f INTO WOOD & STEEL Insert the appropriate nut driver into a 3/8'or 1/2"portable drill Insert the SAMMYS" into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2"or metric all thread rod, bolt stock. (The 1/2" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8"or 1/2" portable drill. Insert the SAMMYS into the #I4SW (re d) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or bolt stock Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS -ZgTUM INTO CONCRETE: Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre -drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock. (#14SWred nut driver used with 1/2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - INTO CONCRETE: I. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8"or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SAMMYSO FOR WOOD i . #14 Black Nut Driver Part #8113910 #4SWRed Nut Driver Part #8114910 No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. FM Test Box is) Load (Ibs) Qty Case Cty 25 125 - 25 25 125 25 125 1 1/4" 8002957 GST 100 114x1 [ 1/4 8003957 GST 200 114x2 1760 (Fr) 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) [ 3/8" 8007957 GST 10 1/4 210 (7/16"OSB) 300 -' 3/8" 8008957 GST 20 114x2" 1760 (Fir) 850 1475 25 125 3/8 8068925 GST 20-SS l/4 x2 60(Rr) 850 25 125j 3/8" 8009925 GST 25-380 318x2-112" 2113 (Fir) 1500 25 125 3/8 8010957 GST 3O 1/4x3 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 3/8 8011925 GST4O 1l4x 2180 (Fir) 25 1/2" 8013925 GST2 114x2 1760 (Fir) 25 - 125 - 1/2 8014925 GST 2.5-380 - 3/8x21/2 2113 (Fir) 25125 1/2" 8015925 GST 3 114 a 3 2275 (Fir) 25 125 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into h contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. I TO i I MI ~ _________________ • No pre-drilling required. if Quick to install using the Sammy Floor joist L Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. pp Reduces installation costs. mp!2 e rTruss Made l the !1UI.1, -1 Cons t ecomm re ing jj5jj8j e oapage 11 Not less than 2" nominal width (1-1/7) up to 3-1/2" pipe: not less than 3" (2-1/2") nominal width 4" & 5" pipe Minimum 2-1/2" from bottom for j branch lines. Minimum 3' from bot- tom for mainlines. Exception: This requirement shall not apply to 2" or thicker nailing stops resting on top of 1/ steel beams. Q I r"• 1/4" 8019957 SWG 200 114x2' 1725 (Fir) 25 125 I 3/8 8020957 SWGIO 1!4x1 622 (Ar) 300 25 125 3/8" 8021957 SWG 20 1/4x2" 1725 (Fir) 1050 25 125 "1 L 3/8 8073925 SWG2O-SS 114x2 1725 (Ar) 850 - 25 125 I 3/8"" 8022925 SWG 25-380 3/8 x 2-1/2 2249 (Fir) 1500 25 125 #14 SW Red LETT 8023925 SWG3O 1/4 x 3 1884 (Ar) - 25 125 Nut Driver Part #8114910 May require pre-drilling; consult joist manufacturer. Eliminates distortion of threaded rod. Accommodates up to 3W x 12 pitch roof. Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. '#14 Black ,Nut Driver - Part# 8113910 4 . #14 SH Orange Nut Driver Part# 8273910 3/8* 8139957 SH-GST20 1/4x2 1257 (Fir) 1050 1475 25 125 3/8' 8141957 SR-GST3O 1/4x3" 1720 (F .. 25 _15 1903 Dim. Lumber 1500 3/8"' 8269957 SK-GST/CST 20 5/16 x 1-3/4' 1406 © 45°off vertical W@45' 25 125 Dim. Lumber 903 Dim. Lumber 1/2' 8303957 Sl4-GST/CST 2.0 5/16 x 1-3/4' 1406 @ 45"off vertical 25 125 Dim. Lumber May require pre.driflisg; consultiolsi manufacture;. PROVALS 8007957 GST 10 3/8" Vertical CPVC 1.1/2' 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2' 300 1-1/2" 8008957 GST2O 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-i12- 8068925 GST2O-SS 3/8" Vertical 2-1/2' 850 1-1/2" 8010957 GST3O 3/8" Vertical 4 1500 1-1/2" 4" 1475 1-1/2" 8009925 GST25-380 3/8' Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8" Horizontal 3-1/2"-4- 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3"" 1050 1-1/2" 8073925 SWG 20-SS 3/8' Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST2O 3/8" 45" Angle off Vertical 4' 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" I 8038957 DSTR1 3/8' Vertical 1500 .035' 4" 1475 .105' 8037957 DSTR 1-1/2 3/8" Vertical 4' 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 EK50 3/8' Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8' Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4' 1500 .037" 4' 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4 1500 .037" 4" 1475 .060" 8137957 SH-DSTR1 3/8' 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEKSO 3/8" Vertical 2-1/2' 850 70" Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2' 850 .027" 2" , 940 029" 1475 .105, 8153922 XP 35 3/8' Vertical 4" 1500 .060 4" 1475 125' 8294922 §XP 20 3/8 Vertical or up to 45 2 750 027" 2 635 029 8295922 SXP35 3/8' Vertical orupto89" 3-1/2" 1250 .060" 2" 635 .029" 8293957 SUP 3/8" Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8' Horizontal 4" 1475 3000 8150922 XP 20 3/8 Vertical 21/2 850 Pre-Pour Structural @3000ps1 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Ranae II LWC 35 PCF (lbs/1131 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 3/8' Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 027" 250 .035' 8294922 SXP2O 3/8" Vertical 170 .027" 45' 80 .027" Vertical 250 .060" 8295922 SXP 35 3/8" 90" 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060' Part Number Model Rod Size Mount Direction UL Load Rating (Ibs) UL Min. Steel Thickness Listed Application 8150922 XP 20 3/8" Vertical 283 .027" Max trade size EMI, RMC, and 1MG & 5 trade size rigid PVC conduit 8153922 XP 35 3/8' Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP20 3/8" Vertical 283 .027' Max 4 trade size EMI, RMC, and 1MG & 5 trade size rigid PVC conduit 8295922 SXP35 3/3" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, 1MG, and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060' Max trade size EMT& 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4" cr3/8" Onto Vertical Rod UL Listed 4S16. Cable Hanger, Cat No. C-Z2000 Plenum Rated, Complies w/ NEC Standards Gauge No. 22 ga. 20 ga. 18 ga. Nominal Decimal Equivalent .030" .036" .048' 'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3.112" *SWG 25-380 Maximum pipe size in wood limber orloist allowed by UL is 4 SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-112" SWG 20 Maxinum sloe size is wood timber or joist allowed by UL is 3' 16 ga. 14 ga. 112 ga. 118" 3/16" 114" .060' .075' .105" .125" .188" .250" UL compliance with NEC Standards. UL and FM tests were performed In compliance with NFPA 13 Standards. Fastening requirement 5 limes weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by ULwere tested in plate steel that measured .188" and .118". Subsequent testing was done for z-pudin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offering. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole rSize GST 2O .182" 1/8" GST 25-380 .280" 7/32" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com PEK*KGER sSOLOA5CONounmCpaunDwAR! AaoLmtDAlmcI.cLwaME 'UI Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made In the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Fig. 25 - Surge Restrainer c®uS LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 COOPER B-Line Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved c YL US USTED Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. ' CORONA, CA 92879 • PH: 951,737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.186.5266 www.tolco.com Fig. 200-I2. 200-I4 Fig. 200-2/2 to 200-8 Fig. 200 Fig. 200S Fla. 200 - "Trimline" Adjustable Band Hanaer (Conner B-Line Fin. B317ONA OV0LC0 Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B3170NFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut c®uS LISTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. ' For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in '.. hanger before before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel J...... materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of - Fig. 200C Fig. 200F .. -,. . - .. 200-/2 1/2" (15) /8'-16 31/8" (79.4) 2I8" (66.7) 11 (50) 200-/4 3/4" (20) /8"-16 31/8" (79.4) 21/2" (63.5) ii (5.0) 200-1 1" (25) /8"-16 3/8" (85.7) 2I8" (66.7) 12 (5.5) 200_11/4 11/4" (32) /8"-16 33/4" (94.0) 2I8" (73.0) 13 (5.9) 200_11/2 11/2" (40) /8"-16 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 2" (50) /8"-16 41/2" (114.3) 3' (76.3) 15 (6.9) 200_21/2 21/2 (65) /8"-16 5/8' (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 5/8' (149.1) 4" (101.6) 29 (13.3) 200_31/2 31/2" (90) /8"-16 7 /8' (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8'-16 7I8' (187.3) 5" (127.0) 35 (16.0) 200-5 (125) 1/2"_13 91/8" (231.8) 61/4 (158.7) 66 (30.2) 200-6 (150) 1/2"_13 101/8" (257.2) 6I4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"_13 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are In inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Ø'OLCO C®US Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe LISTED Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: - (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe 44 types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) FIg.200-lto200-2 B 7 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and A Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 - - and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, 11- Type 10. Fig. 200-/2. 200-/4 Maximum Temperature: 650°F (343°C) Fig. 20021/2 to 200-8 Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. 200M8-1/2 1/2" (15) M8 31/8" (79.4) 2I8" (66.7) 11 (5.0) 200M10-1/2 1/2° (15) MiO 31/8' (79.4) 2/8" (66.7) ii (5.0) 2001Y18-3/4 3/4" (20) M8 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M10 31/8" (79.4) 21/2" (63.5) ii (5.0) 2008-1 1° (25) M8 3I8" (85.7) 2/8" (66.7) 12 (5.5) 200M1-1 1° (25) M10 3I8" (85.7) 2/8" (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4' (32) MiO 33/4" (94.0) 2I8' (73.0) 13 (5.9) 200M8-11/2 11/2' (40) M8 3/8" (98.4) 2I8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) MiO 3I8' (98.4) 2/8" (73.0) 14 (6.4) 200M8-2 2" (50) M8 41/2' (114.3) 3" (76.3) 15 (6.9) 200M10-2 2° (50) M10 41/2' (114.3) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3° (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 3/2" (90) MiO 7I8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4° (100) M10 7I8" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4' (158.7) 66 (30.2) 200M-6 6' (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8" (200) M12 131/8" (333.4) 8I4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line IMT YS]1uujRi 111111111 1111111 Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8'-16 or 1/213 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. : • 1•- D) I) }. 200H-2-3/8 2" (50) /8"-16 4/16" (115.9) 3/32" (81.7) 48 (21.8) 200H-2-1/2 2" (50) 1/2"13 423/32' (119.8) 3/8" (85.7) 45 (20.4) 200H-21/2-3/8 21/2' (65) I8"-16 5/16" (134.9) 323/32" (94.4) 59 (26.7) 200H-21/2-1/2 21/2' (65) 1/2"13 515/32" (138.9) 3/8" (98.3) 56 (25.4) 200II-3-/8 3" (75) I8"-16 53/4" (146.0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"13 5/8" (148.1) 331/32" (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8'-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4" (100) 1/2"_13 71/32° (178.6) 419/32' (1116.7) 1 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8' pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. DO COOR B-Line F PP I Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. jycr ; H Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ' System Compatible Program* Certified to NSF/ANS/Std 61 -G MCK SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gI drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Nu © 2012 Fire Protection Products, Inc. FPPI®, LubeFit5 are registered trademarks of Fire Protection Products, Inc. kb A FGG/BM/CZ, Blaze-Master', FlowGuard Go/d° and Corzad° are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. pipefir F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. MS/1. SYSTEM cOMPATIBI. *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 g. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPPI5, LubeFit2' are registered trademarks of Fire Protection Products, Inc. FBC", BlazeMaste,4, HowGuard Gold5 and Corzan5 are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. lip @Ni3 TftJffRJ @IIIIj offI TONL F PP I® Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. -w © 2013 Fire Protection Products, Inc. FPP!B ThreadW are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke [FC SYSTEM COMPA11BLE *FBC" System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300. III iAU•u U! I l_