HomeMy WebLinkAbout5840 EL CAMINO REAL; ; AS160188; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160188 5840 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 2090503200 Lot #: 0 Reference No.: Status: ISSUED Applied 6/14/2016 Approved: 6/29/2016 Issued: 6/29/2016 PC #: Inspector: Project Title: CELONOVA BIOSCIENCES T.I.: SPRINKLER SYSTEM (12) FIRE SPRINKLERS TO EXISTING SYSTEM IN CLEAN ROOM EXPANSION Applicant: Owner: PACIFIC FIRE SUPPRESSION, INC FENTON CARLSBAD L L C 1642 S. CLEMENTINE ST 7577 MISSION VALLEY RD ANAHEIM, CA SAN DIEGO CA 714-502-0211 Fees ($) Add'I Fees ($) Total ($) Balance ($) 303 0 303 0 Pacific Fire Suppression, Inc. 1.070 N. Batavia #E-318, Orange.. CA 92867 Ph. (714) 283-0211 Fax (714) 283-0214 License# 423418 / C-16 Material Cut Sheet Submittal for: CeloNova 5840 El Camino Real Carlsbad, CA Date: 6/13/16 By:C.H. I FILE CO AS 1 60188 5840 EL CAM INO REAL : - Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has No Thread Warning Has a Pressure Rating of 300 psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-135 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs 1 ij0: '10 * Edciythread 40 can be hot dipped galvanized to meet FM'S requirement for dry systems N 1819 ) Clarkson Road For additional information, Ui Chesterfield, MO 63017 contact your salesperson today at US oui.i. ry (800) 325-4467 (800) 325-4467 or (636) 537-2600 LISTEO FAX: (636) 537-2645 in the USA, or from Canada call(800) 882666 FM AcEcompany e-mail i APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 02/03 FIG. 3201 900 Elbow APPROVED 'Approval Details and limitations, eebs4e at vovw.anviltdl.cen or nAnvprSales Ropresentstive. FIGURE 32.1 900 ELBOW Nominal Size MaximumDimension A Approx. WI. Each Working PressureA In. (mm) PS1(kfi) In. (mm) Lb (kg) 1 500 1.50 0.62 2i 4450 1/4 500 1.75 0.90 11/i 500 1.94 1.20 347) 42276 2 500 2.25 1.85 * -Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest IJIJUIC, and FM pressure ratings verses pipe schedule, please visit anvilintl.com or contact your focal Anvil Representative. MATERIAL SPECIFICATIONS Dimensions: ASME B'16.3 Material: ASTM A536 Grade 6545-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPFI1)I-1.15 FIG. 3221R Reducing Coupling liSTED APPROVED For Lisnngs/Approvai Details and Umitotions, vt our wabotie at w.envtintLuom or corded an ArMP Sates Reprasefttaboe, FIGURE 3221R - REDUCING I ā€¢1I1!iIkE Nominal Size MaximumDimension Working Fressure* A Approx. WI. Eath In. (nini) PSI (kPa) In. (mm) 1h (kg) 1 x1 500 1.69 0.39 25;:L 1 xY4 500 1.69 0.53 257 U24 A -Working Pressure Ratings are for reference only and based on Sd. 40 pipe. For the latest ULJULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B1 6.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fillings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than Four turns. PROJECT INFORMATION APPROVAL STAMP Project: flApproved Address: []Approved as noted Contractor: fJ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 Usm 491a/27 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3A, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1¼ through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are IJL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes. Contact Victaulic for other optional coatings. Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 6545-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E' Type A Gasket System, Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A.449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No.________________________ Submitted By Spec Sect- Para_________ Location Date_______________________________ Approved Date_________________________________ www.victaulic.com 'jictaukcr VICTAULIC Is A REGISTERED TRADEMARK OF vtcruuc COMPANY. 0 2009 viclAulic COMPANY. ALL RIGHTS RESERVED. PS CAROH SIEEL PiPE HOLE CUT PRODUCTS 10.52 STYLE 922 DIMENSIONS '7 MIR USE I I 1¼ Vz 13/16 130 183 110 3.81 2.56 1.0 32 x 15. 30.2 33.0 465 27.9 98.3 65.0 - 0.45 3A 13/16 1.28 1.83 1.10 3.87 2.56 1.1 201 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 13/16 1.52 2.18. 1.10 3.87 2.56 1.2 25 - 30.2 38.6 554 27.9 98.3 65.0 054 1½ 1h 13/16 1.42 1.95 1.22 4.08 236 1.2 40 15- 30.2 36.1 493 31.0 103.6 65.0 034 16 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30,2 35.6 495 31.0 103.6 65.0 054 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 ' 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 ½ : 13/16 1.66 2.19 1.46 4.60 236 13 50 x 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 16 13/16 1.64 2.19 1,46 4.60 256 1.4 20 - 30.2 41.7 55.6 37.1 116.8 , 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 236 15 25 30.2 47.8 643 37.1 1168 65.0 0.68 2½ ½ . 13/16 1.91 2.44 1,71 5.40 2.56 1.6 65 15 1 30.2 48.5 , 62.0 43.4 137.2 65.0 0.73 Y, 13/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 - I 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 1372 65.0 0.73 t'S 1 13/16 1.91 2.44 1.71 550 2.56 1.6 761 mm x 15 30.2 483 62.0 43.4 139.765.0 0.73 N4 13/16 1.89 2.44 1.71 530 236 1.6 20 .' 30.2 48.0 62.0 434 139.7 ...0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1,7 25 . 30.2 54.1 70.9 43.4 139.7 .65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or USPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victauhc.com V1CTAULIG IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 vlCtAtJLIC COMPANY. ALL RIGHTS RESERVED. \4tauhc IMPERIAL MAX REC. LOAD LBS. PIPE .!!!_ .22.. 112 3/8 400 10 3/4 318 400 20 10 400 25 10 - 11/4 400 32 10 ir 400 40 10 2 3/8 400 50 _..2_ 21/2 3/8 600 65 10 3 600 89_ 12.... 3 1/2 3/8 600 -10 4 318 1000 _122 _lll - 1250 ā€”125 12 6 . 1250 150 12 r 1/2 ā€”_ 1250 200 12 Order Part #300m Note: 1/2" Ring Ranger not <FM> approved P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEEUCPVC 1/2 and 3/4 inch pipe 5 thru 8 inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - c®us 203-EX 2551 <a> Approval guide - Pipe Hangers OSUPD OPA-060 1 See Website. CONFORMS WITH: Federal Specification WW-H-171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION - PerNFPA-13, 13R and 13D. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. 2/07 - 8007957.GS1' X CPVC1-112 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST20 SS X 2-1/2 850 1.5 80109571 GST30 . X 4 1500 1.5 X 4 1475 1.5 8009925 GST25-380 X 4 1500 1.5 8022925 MG 25-38G X 3-1/2-4' 1500 1.5 8021957 SWG 20 X 2-1/2-3" 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SHGST20 X 3 1050 1.5 X 4 1475 1.5 8141957 SHGST30 X 4 1500 1.5 X 4 1475 15 NO mill 8038957 DSTR .1 X 4 1500 .035 X 4 1475 .1050 8037957 DSTR 1-1/2 X 4 1500 .035 X 4 1475 .1050 8039957 DSTR 516 X 4 1500 .037 .X 4 1475 .1050 8045957 DST 516 X 4 1500 .188 X 4 1475 .1875 8046957 TEK50 X 4 1500 .250 X 4 1475 . i875 8055957 SWDR 1 X 4 1500 .037 X 4 1475 .0600 8056957 SWDR 516 X 4 1500 .037 X 4 1475 .0600 8054957 SWDR 1-1(2 X 4 1500 .037 X 4 1475 .0600 8137957 St-I DSTR 1 X 4 1500 .035 X 4 1475 .1350 8150922 XP 20 X 2-1/2 850 .027 X 4 1475 .1050 8153922 XP O5 X 3-1/2 1250 .043 X 4 1475 . .1050 8294922 SXP 20 X 2 750 .027 X 4 1475 8295922 SXP 35 X 3-1/2 1250 .060 X 4 1475 8293957 SWXP 35 X 3-1/2 1250 .060 X 4 1475 No. Part Concrete UL lii Max Pip.: MW PSI FM FM Max 77 FM Test latenat 8059957 CST 20 3000 X 4 1475 3000 PSI 8061957 SWC20 3000 X 4 1475 3000 PSI 8150922 )(P* 20' X 2-112 850 Pre Pour Structural 3000 PSI 8150922 XP 20 X 2-1/2 850 Post Pour Range U LWC !g 35 PCF 'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2' SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4' SWG 20 Maximum pipe size In composite wood joist allowed by UL is 2-1/2' "SWG 20 Maximum pipe size in wood Umber or joist allowed by UL is 2-1/2' SXP 20 Maximum allowable angle in 22 ga. steel is 45' UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement. 5 Umax weIghts of water filled schedule 40 pipe 250 pounds. :3k. !Y/I,JthJeX www.itwbuitdex.com 800-BUILDEX SSS39 082007 tqco Fire Protection Products Worldwide Contacts j www.tyco-fire.com Series RFI1 - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate/ Retainer Assembly and a Sprinkler/ Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush Ii" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb 1Y3551 - 5 mm bulb APRIL 2016 Technical Data Sprinkler Approvals Approvals apply only to the service conditions Indicated in the Design Criteria section. TY3531 (3 mm Bulb) is UL Listed, C-UL Listed and NYC Approved (MEA 353-01-E) as Quick Response. TY3531 (3 mm Bulb) is VdS Approved (Certificate No. G4090007). TY3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note; FM and LPCB do not approve concealed sprinklers for quick response. TY3551 (5 mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFH Standard Response Concealed Sprinkler (TY3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM. VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler With 139°F (59°C) Plate 200° F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/ps11'2 (80,6 LPM/barll2) TFPI8I TFPI8I Page 2 of 4 1/2 NPT SEALING ASSEMBLY FRAME CAP SUPPORT CUP WITH BULB 4 ROLLFORMED THREADS T1 COMPRESSION GUIDE SCREW PINS (2) DEFLECTOR DEFLECTOR Il POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO Ii II RETAINER SUPPORT WITH THREAD CUP UNTIL 0 0 DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup. . .......... Chrome Plated Steel Guide Pins..................Stainless Steel Deflector ..........................Bronze Compression Screw ..................Brass Bulb...............................Glass Cap .....................Bronze or Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer............................Brass Election Spring ..............Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Protection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. UL.JItI, Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFll Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. 3/16" to 11/16' (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B MANUFACTURER DEFLECTOR PRESET GAP IN DROPPED 3/32(2,4 mm) POSITION COVER PLATE DIAMETER DIMENSION A COVER PLATE RETAINER ASSEMBLY 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2' (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER DIMENSION 7 ;d WL'Lā€¢1ILW As long as the Protective Cap remains in place, the system is considered 'Out of Service' Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. TFPI8I Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL BEVEL AS COVER SHOWN PLATE RETAINER ASSEMBLY , AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURES OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TV355I) Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. Care and Maintenance The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a Soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N* (specify): 155°F (68°C) 200-F 193-C TY3531 51-792-1-155 51-792-1-200 1Y3551 51-790-1-155 51-790-1-200 Use Suffix '1" for ISO 7-1 connection; for example, 51-792-1-155-I Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from below) Series REII Concealed Cover Plate with (finish), PIN (specify). 139°F (59°C)(a) 165°F (74C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003) .... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome........ 56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200'F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFlI Sprinkler Wrench, P/N 56-000-1-075 Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-62-0700 Copyright 02016 Tyco Fire Products, LP. All rights reserved. tuco TEFLON is trademarkof The DuPont Corporation Fire Protection Products