HomeMy WebLinkAbout5840 EL CAMINO REAL; ; AS160188; PermitCity of Carlsbad
Sprinkler Permit
Permit No: AS160188
5840 EL CAM INO
Job Address:
REAL
Permit Type: SPRINK
Parcel No: 2090503200
Lot #: 0
Reference No.:
Status: ISSUED
Applied 6/14/2016
Approved: 6/29/2016
Issued: 6/29/2016
PC #: Inspector:
Project Title: CELONOVA BIOSCIENCES T.I.: SPRINKLER SYSTEM (12) FIRE
SPRINKLERS TO EXISTING SYSTEM IN CLEAN ROOM
EXPANSION
Applicant: Owner:
PACIFIC FIRE SUPPRESSION, INC FENTON CARLSBAD L L C
1642 S. CLEMENTINE ST 7577 MISSION VALLEY RD
ANAHEIM, CA SAN DIEGO CA
714-502-0211
Fees ($) Add'I Fees ($) Total ($) Balance ($)
303 0 303 0
Pacific Fire Suppression, Inc.
1.070 N. Batavia #E-318, Orange.. CA 92867
Ph. (714) 283-0211
Fax (714) 283-0214
License# 423418 / C-16
Material Cut Sheet Submittal for:
CeloNova
5840 El Camino Real
Carlsbad, CA
Date: 6/13/16
By:C.H.
I
FILE CO
AS 1 60188
5840 EL CAM INO REAL
:
-
Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe
products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our
customers have an option to buy a carefully designed replacement for Schedule 40 that:
Has a Corrosion Resistance Ratio of 1.0
Has No Thread Warning
Has a Pressure Rating of 300 psi
Is Lighter Weight Than Schedule 40
Is Approved by Factory Mutual and Listed by Underwriters Laboratories
Is Produced in Accordance to ASTM A-135 and A-795
Can be Used With Standard Schedule 40 Threaded Fittings,
Couplings and Valves
Is Produced From Steel With Excellent Properties of
Strength and Threadability
Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems*
Offers Lower Freight Costs
1 ij0: '10
* Edciythread 40 can be hot dipped galvanized to meet FM'S requirement for dry systems
N 1819 ) Clarkson Road For additional information, Ui
Chesterfield, MO 63017 contact your salesperson today at US
oui.i. ry (800) 325-4467 (800) 325-4467 or (636) 537-2600 LISTEO
FAX: (636) 537-2645 in the USA, or from Canada
call(800) 882666 FM
AcEcompany e-mail i
APPROVED
All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation.
02/03
FIG. 3201
900 Elbow
APPROVED
'Approval Details and limitations,
eebs4e at vovw.anviltdl.cen or
nAnvprSales Ropresentstive.
FIGURE 32.1 900 ELBOW
Nominal Size MaximumDimension A Approx. WI. Each Working PressureA
In. (mm) PS1(kfi) In. (mm) Lb (kg)
1 500 1.50 0.62
2i 4450
1/4 500 1.75 0.90
11/i 500 1.94 1.20
347) 42276
2 500 2.25 1.85
* -Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the
latest IJIJUIC, and FM pressure ratings verses pipe schedule, please visit anvilintl.com or
contact your focal Anvil Representative.
MATERIAL SPECIFICATIONS
Dimensions: ASME B'16.3
Material: ASTM A536 Grade 6545-12
Finish: Black
Threads: NPT per ASME B1.20.1
Agency Approvals: All ductile iron threaded fittings are
UL/ULC Listed and FM Approved.
NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe.
Therefore, over tightening can cause damage to pipe threads which may cause
leakage. Ductile iron fittings should be tightened approximately three turns beyond
hand tight, but no more than four turns.
SPFI1)I-1.15
FIG. 3221R
Reducing Coupling
liSTED APPROVED
For Lisnngs/Approvai Details and Umitotions,
vt our wabotie at w.envtintLuom or
corded an ArMP Sates Reprasefttaboe,
FIGURE 3221R - REDUCING I ā¢1I1!iIkE
Nominal Size MaximumDimension Working Fressure* A Approx. WI. Eath
In. (nini) PSI (kPa) In. (mm) 1h (kg)
1 x1 500 1.69 0.39
25;:L
1 xY4 500 1.69 0.53
257 U24
A -Working Pressure Ratings are for reference only and based on Sd. 40 pipe. For the
latest ULJULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or
contact your local Anvil Representative.
Dimensions: ASME B1 6.3
Material: ASTM A536 Grade 65-45-12
Finish: Black
Threads: NPT per ASME B1.20.1
Agency Approvals: All ductile iron threaded fillings are
UL/ULC Listed and FM Approved.
NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe.
Therefore, over tightening can cause damage to pipe threads which may cause
leakage. Ductile iron fittings should be tightened approximately three turns beyond
hand tight, but no more than Four turns.
PROJECT INFORMATION APPROVAL STAMP
Project: flApproved
Address: []Approved as noted
Contractor: fJ Not approved
Engineer: Remarks:
Submittal Date:
Notes 1:
Notes 2:
SPF/Dl-1 .15
Usm 491a/27
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLE 922
The Style 922 Outlet-T provides a convenient method of incorporating ½, 3A, and 1/15, 20
and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and
other outlet products. Available for 1¼ through 76.1 mm/32 to 76.1 mm piping systems, Style
922 outlets are IJL/ULC Listed, LPCB and FM Approved for branch connections and VdS
Approved for direct sprinkler connection only on wet and dry systems.
The locating collar engages into the hole prepared in the pipe. When tightened, the assembly
compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up
to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire
protection systems.
Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.
Contact Victaulic for other optional coatings.
Consult Section 10.01 for specific listings/approvals.
MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 6545-12. Ductile iron conforming to
ASTM A-395, grade 65-45-15, is available upon special request.
Gasket
Grade "E" EPDM - Type A
(Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and
Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the
rated working pressure using the Grade "E' Type A Gasket System,
Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical
requirements of ASTM A.449 and physical requirements of ASTM A-183.
Housing Coating:
Orange enamel (North America, Latin America, Asia Pacific)
Red enamel (Europe)
JOB/OWNER CONTRACTOR ENGINEER
System No.________________________ Submitted By Spec Sect- Para_________
Location Date_______________________________ Approved
Date_________________________________
www.victaulic.com 'jictaukcr
VICTAULIC Is A REGISTERED TRADEMARK OF vtcruuc COMPANY. 0 2009 viclAulic COMPANY. ALL RIGHTS RESERVED.
PS CAROH SIEEL PiPE HOLE CUT PRODUCTS 10.52
STYLE 922
DIMENSIONS
'7 MIR USE
I I
1¼ Vz 13/16 130 183 110 3.81 2.56 1.0
32 x 15. 30.2 33.0 465 27.9 98.3 65.0 - 0.45
3A 13/16 1.28 1.83 1.10 3.87 2.56 1.1
201 30.2 32.5 46.5 27.9 98.3 65.0 0.50
1 13/16 1.52 2.18. 1.10 3.87 2.56 1.2
25 - 30.2 38.6 554 27.9 98.3 65.0 054
1½ 1h 13/16 1.42 1.95 1.22 4.08 236 1.2
40 15- 30.2 36.1 493 31.0 103.6 65.0 034
16 13/16 1.40 1.95 1.22 4.08 2.56 1.2
20 30,2 35.6 495 31.0 103.6 65.0 054
1 13/16 1.64 2.30 1.22 4.08 2.56 1.3
25 ' 30.2 41.7 58.4 31.0 103.6 65.0 0.59
2 ½ : 13/16 1.66 2.19 1.46 4.60 236 13
50 x 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59
16 13/16 1.64 2.19 1,46 4.60 256 1.4
20 - 30.2 41.7 55.6 37.1 116.8 , 65.0 0.64
1 13/16 1.88 2.54 1.46 4.60 236 15
25 30.2 47.8 643 37.1 1168 65.0 0.68
2½ ½ . 13/16 1.91 2.44 1,71 5.40 2.56 1.6
65 15 1 30.2 48.5 , 62.0 43.4 137.2 65.0 0.73
Y, 13/16 1.89 2.44 1.71 5.40 2.56 1.6
20 30.2 48.0 62.0 43.4 137.2 65.0 0.73
-
I 13/16 2.13 2.79 1.71 5.40 2.56 1.6
25 30.2 54.1 70.9 43.4 1372 65.0 0.73
t'S 1 13/16 1.91 2.44 1.71 550 2.56 1.6 761 mm x 15 30.2 483 62.0 43.4 139.765.0 0.73
N4 13/16 1.89 2.44 1.71 530 236 1.6
20 .' 30.2 48.0 62.0 434 139.7 ...0.73
1 13/16 2.13 2.79 1.71 5.50 2.56 1,7
25 . 30.2 54.1 70.9 43.4 139.7 .65.0 0.80
t Victaulic female threaded products are designed to accommodate standard NPT or USPT (optional)
male pipe threads only. Use of male threaded products with special features, such as probes, dry pen-
dent sprinklers, etc., should be verified as suitable for use with this Victaulic product Failure to verify
suitability in advance may result in assembly problems or leakage.
Center of run to engaged pipe end for NPT threads (dimensions are approximate).
www.victauhc.com
V1CTAULIG IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 vlCtAtJLIC COMPANY. ALL RIGHTS RESERVED. \4tauhc
IMPERIAL MAX REC.
LOAD LBS. PIPE .!!!_ .22..
112 3/8 400 10
3/4 318 400 20 10
400 25 10
-
11/4 400 32 10 ir 400 40 10
2 3/8 400 50 _..2_
21/2 3/8 600 65 10
3 600 89_ 12....
3 1/2 3/8 600
-10
4 318 1000 _122 _lll
- 1250 ā125 12
6 . 1250 150 12
r 1/2
ā_
1250 200 12
Order Part #300m
Note: 1/2" Ring Ranger not <FM> approved
P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org
300
RING HANGER
I thru 4 inch pipe
LISTED FOR STEEUCPVC
1/2 and 3/4 inch pipe
5 thru 8 inch pipe
SIZE - 1/2 thru 8 inch pipe.
MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec.
LISTING/APPROVAL -
c®us 203-EX 2551 <a> Approval guide - Pipe Hangers
OSUPD OPA-060 1 See Website.
CONFORMS WITH: Federal Specification WW-H-171 (Type 10,
Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10).
MAXIMUM TEMPERATURE - 650°F.
FUNCTION - Pipe hanger component for use on steel, CPVC or
copper piping.
INSTALLATION - PerNFPA-13, 13R and 13D.
FEATURES -
* Sized and listed exclusively for use with #310 Surge Restrainer.
* Band edge is offset for EASY pipe insertion.
* Custom fit swivel nut for better retention in ring body.
* Full length knurl on swivel nut for better grip.
ORDERING - Part #, pipe size.
2/07
-
8007957.GS1' X CPVC1-112 300 1.5
8020957 SWG 10 X CPVC 1-1/2 300 1.5
8008957 GST20 X 2-1/2 850 1.5 X 4 1475 1.5
8068925 GST20 SS X 2-1/2 850 1.5
80109571 GST30 . X 4 1500 1.5 X 4 1475 1.5
8009925 GST25-380 X 4 1500 1.5
8022925 MG 25-38G X 3-1/2-4' 1500 1.5
8021957 SWG 20 X 2-1/2-3" 1250 1.5
8073925 SWG 20 SS X 2-1/2 1250 1.5
8139957 SHGST20 X 3 1050 1.5 X 4 1475 1.5
8141957 SHGST30 X 4 1500 1.5 X 4 1475 15
NO
mill
8038957 DSTR .1 X 4 1500 .035 X 4 1475 .1050
8037957 DSTR 1-1/2 X 4 1500 .035 X 4 1475 .1050
8039957 DSTR 516 X 4 1500 .037 .X 4 1475 .1050
8045957 DST 516 X 4 1500 .188 X 4 1475 .1875
8046957 TEK50 X 4 1500 .250 X 4 1475 . i875
8055957 SWDR 1 X 4 1500 .037 X 4 1475 .0600
8056957 SWDR 516 X 4 1500 .037 X 4 1475 .0600
8054957 SWDR 1-1(2 X 4 1500 .037 X 4 1475 .0600
8137957 St-I DSTR 1 X 4 1500 .035 X 4 1475 .1350
8150922 XP 20 X 2-1/2 850 .027 X 4 1475 .1050
8153922 XP O5 X 3-1/2 1250 .043 X 4 1475 . .1050
8294922 SXP 20 X 2 750 .027 X 4 1475
8295922 SXP 35 X 3-1/2 1250 .060 X 4 1475
8293957 SWXP 35 X 3-1/2 1250 .060 X 4 1475
No. Part Concrete UL lii Max Pip.: MW PSI FM FM Max 77 FM Test latenat
8059957 CST 20 3000 X 4 1475 3000 PSI
8061957 SWC20 3000 X 4 1475 3000 PSI
8150922 )(P* 20' X 2-112 850 Pre Pour Structural 3000 PSI
8150922 XP 20 X 2-1/2 850 Post Pour Range U LWC !g 35 PCF
'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2'
SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4'
SWG 20 Maximum pipe size In composite wood joist allowed by UL is 2-1/2'
"SWG 20 Maximum pipe size in wood Umber or joist allowed by UL is 2-1/2'
SXP 20 Maximum allowable angle in 22 ga. steel is 45'
UL and FM tests were performed in compliance with NFPA 13 Standards.
Fastening requirement. 5 Umax weIghts of water filled schedule 40 pipe 250 pounds.
:3k. !Y/I,JthJeX
www.itwbuitdex.com
800-BUILDEX
SSS39 082007
tqco
Fire Protection
Products
Worldwide
Contacts j www.tyco-fire.com
Series RFI1 - 56 K-factor
"Royal Flush II" Concealed Pendent Sprinklers
Quick & Standard Response, Standard Coverage
General
Description
The TYCO Series RFII 5.6 K-factor,
"Royal Flush II" Concealed Pendent
Sprinklers Quick Response (3-mm
bulb) and Standard Response (5-mm
bulb), are decorative sprinklers fea-
turing a flat cover plate designed to
conceal the sprinkler. These sprinklers
are optimal for architecturally sensi-
tive areas such as hotel lobbies, office
buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/
Retainer Assembly and a Sprinkler/
Support Cup Assembly. The separa-
ble, two-piece assembly design pro-
vides the following benefits:
Allows installation of the sprinklers
and pressure testing of the fire pro-
tection system prior to installation of
a suspended ceiling or application of
the finish coating to a fixed ceiling.
Permits the removal of suspended
ceiling panels for access to building
service equipment without having
to first shut down the fire protection
system and remove sprinklers.
Provides for 1/2 inch (12,7 mm)
of vertical adjustment to allow a
measure of flexibility in determining
the length of fixed piping to cut for
the sprinkler drops.
The Series RFll Sprinklers are shipped
with a Disposable Protective Cap. The
Protective Cap is temporarily removed
during installation and replaced to help
protect the sprinkler during ceiling
installation or finish. The tip of the Pro-
IMPORTANT
Always refer to Technical Data
Sheet TFP 700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 4
tective Cap can be used to mark the
center of the ceiling hole into plaster
board or ceiling tiles by gently pushing
the ceiling product against the Pro-
tective Cap. When ceiling installa-
tion is complete, the Protective Cap is
removed and the Cover Plate/Retainer
Assembly is installed.
As an option, the Series RFll Standard
Response (5-mm bulb) "Royal Flush Ii"
Concealed Pendent Sprinklers can be
fitted with a silicone Air and Dust Seal.
(Refer to Figure 5.) The Air and Dust
Seal is intended for sensitive areas
where it is desirable to prevent air and
dust from the area above the ceiling to
pass through the cover plate.
The Series RFII Concealed Pendent
Sprinklers described herein must be
installed and maintained in compliance
with this document and with the appli-
cable standards of the National Fire
Protection Association, in addition to
the standards of any authorities having
jurisdiction. Failure to do so may impair
the performance of these devices.
The owner is responsible for maintain-
ing their fire protection system and
devices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted with
any questions.
Sprinkler
Identification
Number (SIN)
TY3531 - 3 mm bulb
1Y3551 - 5 mm bulb
APRIL 2016
Technical
Data
Sprinkler Approvals
Approvals apply only to the service
conditions Indicated in the Design Criteria
section.
TY3531 (3 mm Bulb) is UL Listed,
C-UL Listed and NYC Approved
(MEA 353-01-E) as Quick Response.
TY3531 (3 mm Bulb) is VdS Approved
(Certificate No. G4090007).
TY3531 (3 mm Bulb) is FM and
LPCB Approved (Ref. No. 094a/10)
as Standard Response.
Note; FM and LPCB do not approve
concealed sprinklers for quick
response.
TY3551 (5 mm Bulb) is UL Listed,
C-UL Listed, FM Approved, LPCB
Approved (Ref. No. 094a/9), and
NYC Approved (MEA 353-01-E) as
Standard Response.
Approvals for Air and Dust Seal
UL and C-UL Listed for use with the RFH
Standard Response Concealed Sprinkler
(TY3551)
Maximum Working Pressure
Maximum 250 psi (17,3 bar) by UL,
C-UL, and NYC
Maximum 175 psi (12,1 bar) by FM. VdS,
and LPCB
Temperature Rating
155°F (68°C) Sprinkler With
139°F (59°C) Plate
200° F (93°C) Sprinkler with
165°F (74°C) Plate
Discharge Coefficient
K= 5.6 GPM/ps11'2 (80,6 LPM/barll2)
TFPI8I
TFPI8I
Page 2 of 4
1/2 NPT SEALING
ASSEMBLY
FRAME CAP
SUPPORT
CUP WITH BULB
4 ROLLFORMED
THREADS
T1 COMPRESSION
GUIDE
SCREW
PINS (2)
DEFLECTOR
DEFLECTOR Il POSITION)
SPRINKLER/SUPPORT CUP
ASSEMBLY
THREAD INTO Ii II RETAINER
SUPPORT WITH THREAD
CUP UNTIL 0 0 DIMPLES
MOUNTING
SURFACE IS EJECTION
FLUSH WITH SPRING
CEILING
SOLDER COVER
TABS (3) COVER PLATE/RETAINER PLATE
ASSEMBLY
FIGURE 1
MODEL RFII CONCEALED SPRINKLER
ASSEMBLY
Adjustment
1/2 inch (12,7 mm)
Finishes
See the Ordering Procedure section.
Physical Characteristics Frame ............................Bronze
Support Cup. . .......... Chrome Plated Steel Guide Pins..................Stainless Steel
Deflector ..........................Bronze
Compression Screw ..................Brass
Bulb...............................Glass
Cap .....................Bronze or Copper
Sealing Assembly.. Beryllium Nickel w/TEFLON
Cover Plate .........................Brass Retainer............................Brass
Election Spring ..............Stainless Steel
Design
Criteria
The TYCO Series RFII 5.6 K-factor,
"Royal Flush II" Concealed Pendent
Sprinklers are intended for fire protec-
tion systems designed in accordance
with the standard installation rules
recognized by the applicable Listing
or Approval agency; for example, UL
Listing is based on NFPA 13 and VdS
Approval is based on the CEA 4001.
For more information on LPCB and VdS
Approvals, contact Tyco Fire Protection
Products at the following office:
Enschede, Netherlands
Telephone: 31-53-428-4444
Fax: 31-53-428-3377
The Series RFII Concealed Pendent
Sprinklers are only listed and approved
with the Series RFII Concealed Cover
Plates having a factory applied finish.
UL.JItI,
Do not use the Series RFII in applica-
tions where the air pressure above the
ceiling is greater than that below. Down
drafts through the Sprinkler/Support
Cup Assembly can delay sprinkler
operation in a fire situation.
Operation
When exposed to heat from a fire, the
Cover Plate, normally soldered to the
Retainer at three points, falls away to
expose the Sprinkler/Support Cup
Assembly.
The Deflector - supported by the
Guide Pins - then drops down to its
operational position.
The glass bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, activating the sprinkler and
allowing water to flow.
Installation
The TYCO Series RFII 5.6 K-factor,
"Royal Flush II" Concealed Pendent
Sprinklers must be installed in accor-
dance with this section.
General Instructions
Do not install any bulb-type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 155°F (68°C) and 3/32
inch (2,4 mm) for the 200°F (93°C) tem-
perature ratings.
A leak-tight 1/2 inch NPT sprinkler
joint should be obtained by applying a
minimum to maximum torque of 7 to 14
ft.-lbs. (9,5 to 19,0 Nm). Higher levels
of torque can distort the sprinkler Inlet
with consequent leakage or impairment
of the sprinkler.
Do not attempt to compensate for
insufficient adjustment in the Sprinkler
by under- or over-tightening the Sprin-
kler/Support Cup Assembly. Re-adjust
the position of the sprinkler fitting to
suit.
Step 1. Install the sprinkler only in the
pendent position with the center-line
of the sprinkler perpendicular to the
mounting surface.
Step 2. Remove the Protective Cap.
Step 3. With pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 4. Wrench-tighten the sprinkler
using only the RFll Sprinkler Wrench.
(Refer to Figure 3.) Apply the RFII
Sprinkler Wrench to the Sprinkler as
shown in Figure 3.
3/16" to 11/16'
(4,8 to 17,5 mm)
REFERENCE
COVER PLATE
PROFILE DEPTH
DIMENSION B
MANUFACTURER DEFLECTOR
PRESET GAP IN DROPPED
3/32(2,4 mm) POSITION
COVER PLATE
DIAMETER
DIMENSION A
COVER PLATE
RETAINER
ASSEMBLY
3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm)
3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm)
FIGURE 2
SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS
TFPI8I
Page 3 of 4
Step 5. Replace the Protective Cap
by pushing it upwards until it bottoms
out against the Support Cup. (Refer
to Figure 4.) The Protective Cap helps
prevent damage to the Deflector and
Arms during ceiling installation and/or
finish. You can also use the Protective
Cap to locate the center of the clear-
ance hole by gently pushing the ceiling
material up against the center point of
the Protective Cap.
FACE OF
SPRINKLER
FITTING
SPRINKLER
SUPPORT CUP
ASSEMBLY
1/2' (12,7 mm)
THREADED
D ADJUSTMENT
FACE
OF CEILING,
RETAINING RING
MOUNTING
SURFACE
CLEARANCE HOLE
- DIAMETER
DIMENSION
7 ;d
WL'Lā¢1ILW
As long as the Protective Cap remains
in place, the system is considered 'Out
of Service'
Step 6. After the ceiling has been
completed with the 2-1/2 inch (63,5
mm) diameter clearance hole and in
preparation for installing the Cover
Plate/Retainer Assembly, remove and
discard the Protective Cap. Verify that
the Deflector moves up and down
freely.
If the Sprinkler is damaged and the
Deflector does not move up and down
freely, replace the entire Sprinkler.
Do not attempt to modify or repair a
damaged sprinkler.
Step 7. When installing an Air and
Dust Seal, refer to Figure 5; otherwise,
proceed to Step 8. To attach the Air
and Dust Seal, verify the angle of the
outside edge of the seal is oriented
according to Figure 5. Start the edge of
the Retainer in the grooved slot of the
Air and Dust Seal and continue around
the retainer until the entire Air and Dust
Seal is engaged.
TFPI8I
Page 4 of 4
SUPPORT SPRINKLER FACE OF ORIENT
CUP CEILING SEAL
BEVEL AS
COVER
SHOWN
PLATE
RETAINER
ASSEMBLY
, AIR
AND DUST
LIP OF COVER SEAL
RETAINER PLATE
FIGURES
OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TV355I)
Step 8. Screw on the Cover Plate/
Retainer Assembly until the Retainer
(shown in Figure 2) or the Air and Dust
Seal (shown in Figure 5) contacts the
ceiling. Do not continue to screw on the
Cover Plate/Retainer Assembly so that
it lifts a ceiling panel out of its normal
position. If you cannot engage the
Cover Plate/Retainer Assembly with
the Support Cup or you cannot engage
the Cover Plate/Retainer Assembly suf-
ficiently to contact the ceiling, you must
reposition the Sprinkler Fitting.
Care and
Maintenance
The TYCO Series RFII 5.6 K-factor,
"Royal Flush II" Concealed Pendent
Sprinklers must be maintained and
serviced in accordance with this
section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
that it controls, obtain permission to
shut down the affected fire protection
system from the proper authorities
and notify all personnel who may be
affected by this action.
Absence of the Cover Plate/Retainer
Assembly can delay sprinkler opera-
tion in a fire situation.
When properly installed, there is a
nominal 3/32 inch (2,4 mm) air gap
between the lip of the Cover Plate and
the ceiling, as shown in Figure 2.
This air gap is necessary for proper
operation of the sprinkler. If the ceiling
requires repainting after sprinkler
installation, ensure that the new paint
does not seal off any of the air gap.
Do not pull the Cover Plate relative to
the Enclosure. Separation may result.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a Soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers - before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb. (Ref. Installa-
tion Section.)
Exercise care to avoid damage to sprin-
klers before, during, and after instal-
lation. Replace sprinklers damaged
by dropping, striking, wrench twist-
ing, wrench slipping, or the like. Also,
replace any sprinkler that has a cracked
bulb or that has lost liquid from its bulb.
(Refer to the Installation section.)
If you must remove a sprinkler, do not
reinstall it or a replacement without
reinstalling the Cover Plate/Retainer
Assembly. If a Cover Plate/Retainer
Assembly becomes dislodged during
service, replace it immediately.
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or sprinkler manufac-
turer regarding any questions.
Automatic sprinkler systems should be
inspected, tested, and maintained by a
qualified Inspection Service in accor-
dance with local requirements and/or
national code.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for
availability. When placing an order,
indicate the full product name.
Sprinkler/Support Cup Assembly
Specify: Series RFII (specify SIN),
K=5.6, "Royal Flush II" Pendent Sprin-
klers (specify) temperature rating and
(specify) finish, P/N* (specify):
155°F (68°C) 200-F 193-C
TY3531 51-792-1-155 51-792-1-200
1Y3551 51-790-1-155 51-790-1-200
Use Suffix '1" for ISO 7-1 connection; for example,
51-792-1-155-I
Separately Ordered Cover Plate/
Retainer Assembly:
Specify: (temperature rating from
below) Series REII Concealed Cover
Plate with (finish), PIN (specify).
139°F (59°C)(a) 165°F (74C)(b)
Grey White
(RAL9002) .... 56-792-0-135 56-792-0-165
Brass..........56-792-1-135 56-792-1-165
Pure White (c)
(RAL9010) .... 56-792-3-135 56-792-3-165
Signal White
(RAL9003) .... 56-792-4-135 56-792-4-165
Jet Black
(RAL9005).... 56-792-6-135 59-792-6-165
Brushed
Chrome........ 56-792-8-135 56-792-8-165
Chrome ........56-792-9-135 56-792-9-165
Custom ........56-792-X-135 56-792-X-165
For use with 155°F (68°C) sprinklers.
For use with 200'F (93°C) sprinklers.
Eastern Hemisphere sales only.
Sprinkler Wrench
Specify: RFlI Sprinkler Wrench,
P/N 56-000-1-075
Air and Dust Seal
Specify: Air and Dust Seal,
P/N 56-908-1-001
GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-62-0700
Copyright 02016 Tyco Fire Products, LP. All rights reserved. tuco
TEFLON is trademarkof The DuPont Corporation Fire Protection Products