Loading...
HomeMy WebLinkAbout5617 PASEO DEL NORTE; ; FA130096; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA130096 5617 PASEO DEL Job Address: NORTE Permit Type: FALARM Parcel No: 2110213400 Lot #: 0 Reference No.: PC #: Status: PENDING Applied 12/13/2013 Approved: Issued: Inspector: Project Title: ARCHIVE BRIDAL TI—PROVIDE NEW FA NOTIFICATION DEVICES AS SHOWN ON PLANS AND CONNECT TO THE EXISTING FA CIRCUIT AS SHOWN. Applicant: JJJ ENTERPRISES 533 5 VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: CPT/SC TITLE HOLDING CORP C/O STRATEGIC PROPERTY ADVISERS I 3250 VISTA DIEGO RD JAMUL CA Fees ($) Add'I Fees ($) Total ($) Balance ($) L 286L0 286 0 THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT r '- FIRE ALARM AND EMERGENCY-COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. PROPERTY INFORMATION INSTALLATION, SERVICE, AND TESTING CONTRACTOR INFORMATION Installation contractor for this equipment: JJJ ENTERPRISES Address: 533 S. VINEWOOD, ESCONDIDO, CA 92029 License or certification number: 582169 Phone: 760-747-3050 Fax: 760-747-7561 E-mail: INFO@JJJENT.COM Service organization for this equipment: Address: License or certification number: Phone: Fax: E-mail: A contract for test and inspection in accordance with NFPA standards is in effect as of: Contracted testing company: Address: Phone: Fax: E-mail: Contract expires: Contract number: Frequency of routine inspections: DESCRIPTION OF SYSTEM OR SERVICE Z Fire alarm system (nonvoice) El Fire alarm with in-building fire emergency voice alarm communication system (EVACS) O Mass notification system (MINS) O Combination system, with the following components: 0 Fire alarm 0 EVACS 0 MNS 0 Two-way, in-building, emergency communication system O Other (specify): NFPA 72, Fig. 10.18.2.1.1 (p.1 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 3. DESCRIPTION OF SYSTEM OR SERVICE (continued) NFPA 72 edition: 2010 Additional description of system(s): 3.1 Control Unit Manufacturer: NOTIFIER Model number: 3.2 Mass Notification System This system does not incorporate an MNS 3.2.1 System Type: D In-building MNS—combination E] In-building MNS—stand-alone 0 Wide-area MNS 0 Distributed recipient MNS El Other (specify): 3.2.2 System Features: E] Combination fire alarm/MNS 0 MNS autonomous control unit 0 Wide-area MNS to regional national alerting interface 0 Local operating console (LOC) 0 Direct recipient MNS (DRMNS) 0 Wide-area MNS to DRMNS interface O Wide-area MNS to high-power speaker array (HPSA) interface 0 In-building MNS to wide-area MNS interface El Other (specify): 3.3 System Documentation 10 An owner's manual, a copy of the manufacturer's instructions, a written sequence of operation, and a copy of the numbered record drawings are stored on site. Location: 3.4 System Software This system does not have alterable site-specific software. Operating system (executive) software revision level: Site-specific software revision date: Revision completed by: El A copy of the site-specific software is stored on site. Location: 3.5 Off-Premises Signal Transmission 0 This system does not have off-premises transmission. Name of organization receiving alarm signals with phone numbers: Alarm: GENERAL MONITORING SERVICES Phone: 888-467-1119 Supervisory: SAME Phone: Trouble: SAME Phone: Entity to which alarms are retransmitted: CARLSBAD FIRE DEPT Phone: Method of retransmission: TELEPHONE CALL If Chapter 26, specify the means of transmission from the protected premises to the supervising station: If Chapter 27, specify the type of auxiliary alarm system: 0 Local energy 0 Shunt Z Wired 0 Wireless NFPA 72, Hg. 10.18.21.1 (p.2 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 4. CIRCUITS AND PATHWAYS 4.1 Signaling Line Pathways 4.1.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: 1 Quantity: (See NFPA 72, Sections 12.3 and 12.4) 4.1.2 Pathways Utilizing Two or More Media Quantity: Description: 4.1.3 Device Power Pathways No separate power pathways from the signaling line pathway o Power pathways are separate but of the same pathway classification as the signaling line pathway El Power pathways are separate and different classification from the signaling line pathway 4.1.4 Isolation Modules Quantity: 4.2 Alarm Initiating Device Pathways 4.2.1 Pathways Class Designations and Survivability Pathways class: Survivability level: Quantity: 0 (See NFPA 72, Sections 12.3 and 12.4) 4.2.2 Pathways Utilizing Two or More Media Quantity: Description: 4.2.3 Device Power Pathways No separate power pathways from the initiating device pathway El Power pathways are separate but of the same pathway classification as the initiating device pathway El Power pathways are separate and different classification from the initiating device pathway 4.3 Non-Voice Audible System Pathways 4.3.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: 1 Quantity: (See NFPA 72, Sections 12.3 and 4.3.2 Pathways Utilizing Two or More Media Quantity: Description: 4.33 Appliance Power Pathways No separate power pathways from the notification appliance pathway El Power pathways are separate but of the same pathway classification as the notification appliance pathway 0 Power pathways are separate and different classification from the notification appliance pathway NFPA 72, Fig. 10.18.2.1.1 (p.3 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 5. ALARM INITIATING DEVICES 5.1 Manual Initiating Devices 5.1.1 Manual Fire Alarm Boxes Type and number of devices: Addressable: Other (specify): 5.1.2 Other Alarm Boxes Description: Type and number of devices: Addressable Other (specify): 5.2 Automatic Initiating Devices This system does not have manual fire alarm boxes. Conventional: Coded: Transmitter: This system does not have other alarm boxes, Conventional: Coded: Transmitter: 5.2.1 Smoke Detectors 10 This system does not have smoke detectors. Type and number of devices: Addressable: Conventional: Other (specify): Type of coverage: 0 Complete area D Partial area 0 Nonrequired partial area Other (specify):. .... Type of smoke detector sensing technology: 0 Ionization 0 Photoelectric 0 Multicriteria 0 Aspirating 0 Beam Other (specify):. ................ 5.2.2 Duct Smoke Detectors 0 This system does not have alarm-causing duct smoke detectors. Type and number of devices: Addressable: 2 Conventional: Other (specify): Type of coverage: AHUS Type of smoke detector sensing technology: 0 Ionization 0 Photoelectric 0 Aspirating 0 Beam 5.2.3 Radiant Energy (Flame) Detectors This system does not have radiant energy detectors. Type and number of devices: Addressable: Conventional: Other (specify): Type of coverage: 5.2.4 Gas Detectors Z This system does not have gas detectors. Type of detector(s): Number of devices: Addressable: Conventional: Type of coverage: 5.2.5 Heat Detectors This system does not have heat detectors. Type and number of devices: Addressable: Conventional: Type of coverage: 0 Complete area 0 Partial area 0 Nonrequired partial area 0 Linear 0 Spot Type of heat detector sensing technology: 0 Fixed temperature 0 Rate-of-rise 0 Rate compensated NFPA 72, Hg. 10.182.1.1 (p.4 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 5. ALARM INITIATING DEVICES (continued) 5.2.6 Addressable Monitoring Modules Number of devices: 1 5.2.7 Waterflow Alarm Devices Type and number of devices: Addressable: 5.2.8 Alarm Verification Number of devices subject to alarm verification: 5.2.9 Presignal Number of devices subject to presignal: Describe presignal functions: 5.2.10 Positive Alarm Sequence (PAS) Describe PAS: 5.2.11 Other Initiating Devices Describe: 0 This system does not have monitoring modules. This system does not have waterfiow alarm devices, Conventional: Coded: Transmitter: This system does not incorporate alarm verification. Alarm verification set for seconds Z This system does not incorporate pre-signal. This system does not incorporate PAS. This system does not have other initiating devices. 6. SUPERVISORY SIGNAL-INITIATING DEVICES 6.1 Sprinkler System Supervisory Devices ID This system does not have sprinkler supervisory devices. Type and number of devices: Addressable: Conventional: Coded: Transmitter: Other (specify): 6.2 Fire Pump Description and Supervisory Devices This system does not have a fire pump. Type fire pump: 0 Electric pump 0 Engine Type and number of devices: Addressable: Conventional: Coded:Transmitter: Other (specify): 6.2.1 Fire Pump Functions Supervised E] Power 0 Running 0 Phase reversal 0 Selector switch not in auto 0 Engine or control panel trouble 0 Low fuel Other (specify): 6.3 Duct Smoke Detectors (DSDs) 0 This system does not have DSDs causing supervisory signals. Type and number of devices: Addressable: 2 Conventional: Other (specify): Type of coverage: AHU'S Type of smoke detector sensing technology: 0 Ionization Z Photoelectric 0 Aspirating 0 Beam 6.4 Other Supervisory Devices Z This system does not have other supervisory devices. Describe: NFPA 72, Fig. 10.18.2.1.1 (p.5 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. MONITORED SYSTEMS 7.1 Engine-Driven Generator 7.1.1 Generator Functions Supervised i:i Engine or control panel trouble U Generator running U Other (specify): 7.2 Special Hazard Suppression Systems Description of special hazard system(s): 7.3 Other Monitoring Systems Description of special hazard system(s): ANNUNCIATORS This system does not have a generator. U Selector switch not in auto U Low fuel This system does not monitor special hazard systems. This system does not monitor other systems. This system does not have annunciators. 8.1 Location and Description of Annunciators Location 1: Location 2: Location 3: 9. ALARM NOTIFICATION APPLIANCES 9.1 In-Building Fire Emergency Voice Alarm Communication System 0 This system does not have an EVACS. Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker circuits: Location of amplification and sound-processing equipment: Location of paging microphone stations: Location 1: Location 2: Location 3: 9.2 Nonvoice Notification Appliances Horns: With visible: Chimes: With visible: Visible only: Other (describe): 9.3 Notification Appliance Power Extender Panels Quantity: Locations: This system does not have nonvoice notification appliances. Bells: With visible: This system does not have power extender panels. NEPA 72, Fig. 1018.21.1 (p.60f12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. MASS NOTIFICATION CONTROLS, APPLIANCES, AND CIRCUITS This system does not have an MNS. 10.1 MNS Local Operating Consoles Location 1: Location 2: Location 3: 10.2 High-Power Speaker Arrays Number of HPSA speaker initiation zones: Location 1: Location 2: Location 3: 10.3 Mass Notification Devices Combination fire alarm/MNS visible appliances: MNS-only visible appliances: Textual signs: Other (describe): Supervision class: 10.3.1 Special Hazard Notification El This system does not have special suppression predischarge notification. E] MNS systems DO NOT override notification appliances required to provide special suppression predischarge notification. TWO-WAY EMERGENCY COMMUNICATION SYSTEMS 11.1 Telephone System 0 This system does not have a two-way telephone system. Number of telephone jacks installed: Number of warden stations installed: Number of telephone handsets stored on site: Type of telephone system installed: 0 Electrically powered 0 Sound powered 11.2 Two-Way Radio Communications Enhancement System O This system does not have a two-way radio communications enhancement system. Percentage of area covered by two-way radio service: Critical areas: % General building areas: % Amplification component locations: Inbound signal strength: dBm Outbound signal strength: dBm Donor antenna isolation is: dB above the signal booster gain Radio frequencies covered: Radio system monitor panel location: NFPA 72, Fig. 10.18.21.1 (p. 7 of 12) Copyright 0 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. TWO-WAY EMERGENCY COMMUNICATION SYSTEMS (continued) 11.3 Area of Refuge (Area of Rescue Assistance) Emergency Communications Systems This system does not have an area of refuge (area of rescue assistance) emergency communications system. Number of stations: Location of central control point: Days and hours when central control point is attended: Location of alternate control point: Days and hours when alternate control point is attended: 11.4 Elevator Emergency Communications Systems This system does not have an elevator emergency communications system. Number of elevators with stations: Location of central control point: Days and hours when central control point is attended: Location of alternate control point: Days and hours when alternate control point is attended: 11.5 Other Two-Way Communication Systems Describe: CONTROL FUNCTIONS This system activates the following control frictions: o Hold-open door releasing devices 0 Smoke management Z HVAC shutdown 0 F/S dampers O Door unlocking 0 Elevator recall 0 Fuel source shutdown 0 Extinguishing agent release E] Elevator shunt trip 0 Mass notification system override of fire alarm notification appliances Other (specify): 12.1 Addressable Control Modules 0 This system does not have control modules. Number of devices: 2 Other (specify): SYSTEM POWER 13.1 Control Unit 13.1.1 Primary Power Input voltage of control panel: 120VAC Control panel amps: 20 Overcurrent protection: Type: BUILT-IN Amps: Location (of primary supply panel board): OUTSIDE Disconnecting means location: MARKED CIRCUIT BREAKER 13.1.2 Engine-Driven Generator This system does not have a generator. Location of generator: Location of fuel storage: Type of fuel: NFPA 72, Fig. 10.18.2.1.1 (p.8 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 13. SYSTEM POWER (continued) 13.1.3 Uninterruptible Power System 0 This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): In alarm mode (minutes): 13.1.4 Batteries Location: FACP CABINET Type: GEL-CELL Nominal voltage: 24VDC Amp/hour rating: 12 Calculated capacity of batteries to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 Batteries are marked with date of manufacture 0 Battery calculations are attached 13.2 In-Building Fire Emergency Voice Alarm Communication System or Mass Notification System Z This system does not have an EVACS or MNS system. 13.2.1 Primary Power Input voltage of EVACS or MI'45 panel: Overcurrent protection: Type: Location (of primary supply panel board): Disconnecting means location: 13.2.2 Engine-Driven Generator Location of generator: Location of fuel storage: EVACS or MNS panel amps: Amps: This system does not have a generator. Type of fuel: 13.2.3 Uninterruptible Power System This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): Inalarm mode (minutes): 13.2.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode (hours): In alarm mode (minutes): 0 Batteries are marked with date of manufacture 0 Battery calculations are attached NFPA 72, Fig. 10.18.2.1.1 (p.9 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 13. SYSTEM POWER (continued) 13.3 Notification Appliance Power Extender Panels 13.3.1 Primary Power Input voltage of power extender panel(s): Overcurrent protection: Type: Location (of primary supply panel board): Disconnecting means location: This system does not have power extender panels. Power extender panel amps: Amps: 13.3.2 Engine-Driven Generator ID This system does not have a generator. Location of generator: Location of fuel storage:Type of fuel: 13.3.3 Uninterruptible Power System This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): In alarm mode (minutes): 13.3.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode (hours):In alarm mode (minutes): U Batteries are marked with date of manufacture U Battery calculations are attached 14. RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operational acceptance tests. This is a: 0 New system Modification to an existing system Permit number: The system has been installed in accordance with the following requirements: (Note any or all that apply.) NFPA 72, Edition: 2010 Z NFPA 70, National Electrical Code, Article 760, Edition: 2008 Manufacturer's published instructions Other (specify): System deviations from referenced NFPA standards: NONE Signed: r4/?.)tc(L Printed name: Marcus Claudius Date: 12/27/2013 Organization: JJJ Enterprises Title: Engineering Manager Phone: 760-747-3050 NFPA 72, Fig. 10.182.1.1 (p. 10 of 12) Copyright 0 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution.