HomeMy WebLinkAbout5600 PASEO DEL NORTE; 105A; FPC2020-0015; PermitPERMIT REPORT (L'City of Carlsbad Print Date: 01/05/2021 Job Address: 5600 PASEO DEL NORTE, # 105A, Permit Type: FIRE-Construction Commercial Parcel #: 2110222201 Valuation: $217,713.31 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: KATE SPADE -SPRINKLER TI (55 HEADS) Applicant: JOHNSON CONTROL FIRE PROTECTION MARCUS ENGLISH 3568 RUFFIN RD SAN DIEGO, CA 92123-2597 (858) 633-9125 CARLSBAD, CA 92008-4441 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0015 Status: Closed - Finaled Applied: 01/29/2020 Issued: Finaled Close Out: 02/28/2020 Inspector: Final Inspection: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP P0 BOX 3042 BOCA RATON, FL 33431-0942 (561) 341-7780 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov tqcao Worldwide Contacts I www.tyco-fire.com Series RFII - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFll 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 in. (12,7 mm) of ver- tical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. L'I.)tL.I The Series RFll Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) 1Y3531 = 3 mm bulb SEPTEMBER 2018 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. TY3531 (3 mm Bulb) is UL Listed, C-UL Listed and NYC Approved (MEA 353- 01-E) as Quick Response. 1Y3531 (3 mm Bulb) is VdS Approved (Certificate No. G4090007). TY3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note: FM and LPCB do not approve concealed sprinklers for quick response. TY3551 (5 mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Cover Plate 200°F (93°C) Sprinkler with 165°F (74°C) Cover Plate TFPI8I THREAD INTO U RETAINER SUPPORT WITH THREAD CUP UNTIL 0 0 %- DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY 1/2 NPT FRAME SUPPOR1 CUP WITE ROLL FORIV THREAD GUIDE PINS (2) DEFLECTOR SPRINKLER/SUPPORT CUP ASSEMBLY EALING SEMBLY CAP BULB IPRESSION CREW FLECTOR ROPPED POSITION) TFP181 Page 2 of 4 Discharge Coefficient K= 5.6 GPM/psi1'2 (80,6 LPM/bar112) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup ...................Plated Steel Guide Pins .................. Stainless Steel Deflector ..........................Bronze Compression Screw..................Brass Bulb ............................... Glass Cap .....................Bronze or Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer............................Brass Ejection Spring ..............Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Johnson Controlss at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. 3/16" to 11/16 MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY COVER PLATE PROFILE DEPTH DIMENSION B 3-1/4 inches (82,6 mm) 3/16 inches (4,8 mm) COVER PLATE DIAMETER DIMENSION A 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPISI Page 3 of 4 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER - DIMENSION C Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. AYL•1tL•i As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been completed with the 2-1/2 in. (63,5 mm) diameter clearance hole and in prep- aration for installing the Cover Plate/ Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. TFPI8I Page 4 of 4 Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. Care and Maintenance The TYCO Series RFll 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 in. (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating, P/N* (specify): 155°F (68°C) 200°F (93°C) T'Y3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 * Use Suffix I" for ISO 7-1 connection; for example, 51-792-1-155-I Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass .......... 56-792-1 -135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003).... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFIl Sprinkler Wrench, P/N 56-000-1-075 Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 C 2018 Johnson Controls. NI rights reserved— MI specifications and ether lnfor,00tlon thaw,, we.'e current as of document revision dale and are subject to change without notice. NATIONAL :IRE PROTECTION ASSOCIATION and NFPA are reginnarad t,odan,arino at National Fire Pnnnocnlon Association; TEFLON Is a registered Sndnn,nnk alOAPnnt Johnson Controls Worldwide ticu Contacts www.tyco-fire.com Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification 3.... Upright 5.6K, 1/2 in. Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar) * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/p5i½ (80,6 LPM/bar½) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly ... Stainless Steel wITEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze AUGUST 2018 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 TFPI72 Page 2 of 4 Components: 1 - Frame 4 - Bulb 2 - Button 5 - Compression 3 - Sealing Screw Assembly 6 - Deflector* * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector. can be provided on special request. ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON * 6 ______ I 7/16 ______ _ I \- I 4 ______ (11,1mm) ______ _________ 2 ______ I NOMINAL MAKE-IN _____ (50,8 mm) /8 ___________ (34,9 mm) DIA. (50,8 mm) _______ 13 2 / / 2° WRENCH FLATS 1/2 NPT** DEFLECTOR * 2-7/8 p3,0 mm) CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS - 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler it the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. / WRENCH RECESS (USE ONLY FIGURE 2 .W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/8 DIA. (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER 5/8 (15,9 mm) FITTING FLUSH 3/8±5/16' (9,5±7,9 mm) I / 1/8 SURFACE j MOUNTING (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4 DIA. 1/2° (12,7 mm) 5/16±1/4 \ _____________ (7,9±6,4 mm) FITTING (57,2 mm) FLUSH MOUNTING /\ 1/8 J I SURFACE/ \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TY-FRB PLATE 7/8 (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED ,,LYESTERC 135°F (57°C) Orange UPRIGHT (TY313) and 1, 2, 3, 4, 5, 6 155°F (68°C) Red 175°F (79°C) Yellow 5.6 1/2 in. NPT PENDENT (TY323) Blue 200°F (93°C) Green 286°F (141°C) ________________ 135°F (57°C) Orange RECESSED PENDENT (TY323) Figures 4a and 5b 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. C. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na77_XX_)_)OO(________ I SPRINKLER TEMPERATURE FINISH RATINGS 1 NATURAL BRASS 135 135°F (57°C) PURE WHITE (RAL9010)a 155 155°F (68°C) POLYESTER Notes: SIGNAL WHITE (RAL9003) a. Use suffix 'I" for ISO 7-1 connection; for example, 4 POLYESTER 175 175-F (79-q 77-370-4-175-I - - JET BLACK (RAL9005) 200 200°F (93°C) POLYESTER 9 CHROME PLATED 286 286°F (141°C) Notes: a. Eastern Hemisphere sales only TABLE SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION SIN 370 5.6K UPRIGHT (1/2 in.NPT) TY313 371 5.6K PENDENT (1/2 in.NPT) TY323 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1.215.362-0700 C 2018 Johnson Controls. All rights reserved. All opocleoatlons and stoop i,do,n,atlon shown wane Ronont on of docon,nnt revision date and are subject to change wlthottt notion. Johnson NATiONAL FIRE PROTECTION ASSOCIATION and NFPAO,0registered tredemo,t,n of Notional Are P,n,ocdan A000da11on; Controls TEFLON ,o9I,arod trRd000,k of DuPont EXISTING TO REMAIN Worldwide I tqL:L70 Contacts www.tyco-fire.com Series EC41 and EC-14 Sprinklers, 11-.2-K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative glass-bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules, such as NFPA 13, for a maximum cov- erage area of 400 ft2 (37,2 m2) as com- pared to the maximum coverage area of 130 ft2 (12,1 m2) for standard cover- age sprinklers used in ordinary hazard occupancies, or the maximum cover- age area of 225 ft2 (20,6 m2) for stan- dard coverage sprinklers used in light hazard occupancies. Series EC-11 and EC-14 Extended Coverage Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combusti- ble obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. Series EC-11 and EC-14 Extended Cov- erage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprinklers. These tests have shown that the pro- tection provided is equal to or more effective than standard coverage spray sprinklers. corrosion-resistant coated sprinklers passed standard corrosion tests of the applicable approval agencies, this testing is not representative of all pos- sible corrosive atmospheres. Conse- quently, it is recommended that the end user be consulted with respect to the suitability of these corrosion-resistant coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity should be considered, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE Series EC-11 and EC-14 Extended Cov- erage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the NFPA, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Au i uli Technical Data Approvals TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are UL and C-UL Listed. Refer to Table A for complete sprinkler approval information including corrosion-resistant status. The approv- als apply to the service conditions indi- cated in the Design Criteria section. Corrosion-resistant coatings, where 1111 Series EC-11 and EC-14 Extended Coy- applicable, help extend the life of TY5137 ............Upright, 11.2K erage Sprinklers are FM Approved. copper alloy sprinklers beyond that approval information including corro-which occurs when exposed to corrosive atmospheres. Although ~~,~~ K Refer to Table A for complete sprinkler sion resistant status. The approvals apply to the service conditions mdi- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page lof8 TY5137 is a re-designation for C5137, G1894, and S2510 TY5237 is a re-designation for C5237, G1893, and S2511 1V6137 is a re-designation for C6137, G1896, and S2610 1Y8237 is re-designation for C6237, G1895, and S2611 DECEMBER 2017 caiea in the uesign tr1ier1a section. The Style 60 Two-Piece Flush Escutch- eon (Figure 4) is UL Listed for use with the Series EC-11 and EC-14 Pendent Sprinklers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 in. NPT TFP22O ESCUTCHEON PLATE SEATING SURFACE '/ 1-11/16° . (42,7 mm: WRENCH 3/40 FLAT NPT** CROSS PENDENT SECTION 2-7/16° (61,9 mm) UPRIGHT & PENDENT 1/2(12,7mm) J NOMINAL MAKE-IN UPRIGHT TFP22O Page 2 of 8 Components: 1 1-Frame 2 - Button 3 - Sealing Assembly 2 4-Bulb 5 - Compression Screw 6 - Deflector 3 * Temperature rating is 4 indicated on Deflector. ** Pipe thread connections per 5 ISO 7-1 can be provided on special request. 6* FIGURE 1 SERIES EC-11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K-FACTOR UPRIGHT (TY6137) AND PENDENT (TY6237) ASSEMBLY Discharge Coefficients K = 11.2 GPM/p51½ (161,3 LPM/bar½) K = 14.0 GPM/psi½ (201,6 LPM/bar½) Temperature Ratings Refer to Table A Finish Sprinkler: Refer to Table A Recessed or Flush Escutcheon: White-Coated, Chrome-Plated, and Brass-Plated Physical Characteristics Frame............................Bronze Button............................Bronze Sealing Assembly . Beryllium Nickel w/TEFLON Bulb ........................Glass (3 mm) Compression Screw ................Bronze Deflector...........................Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which- then allows the sprinkler to activate and flow water. Design Criteria TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers must only be installed in accordance with the appli- cable UL and C-UL Listing or FM Approval requirements as indicated below. Only Style 30 or 40 Recessed Escutcheons are to be used for recessed installation, as applicable. Refer to Tables A, B, and C, for more information. UL and C-UL Listing Requirements Series EC-11 and EC-14 Extended Coverage Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and haz- ard group for all sprinklers in the design area. Series EC-11 and EC-14 Extended Coverage Sprinklers are permitted to be used with unobstructed or non-combustible obstructed ceil- ing construction as defined and permitted by NFPA 13; for example: Unobstructed, combustible or noncombustible, ceiling con- struction with a deflector to ceiling/roof deck distance of 1 t 12 in. (25 to 300 mm). Obstructed, non-combusti- ble, ceiling construction with a deflector location below struc- tural members of 1 to 6 in. (25 to 150 mm) and a maximum deflector to ceiling/roof deck dis- tance of 22 in. (550 mm). Series EC-11 and EC-14 Extended Coverage Sprinklers, specifically tested and listed for non-combus- tible obstructed construction, are permitted to be used within truss- es or bar joists having non-com- bustible web members greater than 1 in. (25.4 mm) when apply- ing the 4 times obstruction crite- ria rule defined under "Obstruc- tions to Sprinkler Discharge Pattern Development". To prevent cold soldering, the minimum allowable spacing be- tween Series EC-11 and EC-14 Ex- tended Coverage Sprinklers is 8 ft (2,4 m) for upright sprinklers and 9 ft (2,7 m) for pendent sprinklers. S. Series EC-11 and EC-14 Extended Coverage Sprinklers are to be in- stalled in accordance with all oth- er requirements of NFPA 13 for extended coverage upright and pendent sprinklers; For exam- ple, obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard and clearance to storage. UL and C-UL Specific Application Listing Requirements for Installation under Concrete Tees Series EC-11 and EC-14 Extended Cov- erage Upright and Pendent Sprinklers (TY5137, TY5237, TY6137 and TY6237) have a UL and C-UL Specific Applica- tion Listing for use under concrete tees when installed as follows: 1. Stems of the concrete tee con- struction must be spaced at less than 7.5 ft (2,3 m) on center but more than 3 ft (0,9 m) on center. The depth of the concrete tees must not exceed 30 in. (762 mm). The maxi- mum permitted concrete tee length is 32 ft (9,8 m). However, where the concrete tee length exceeds 32 ft (9,8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 ft (9,8 m) in length. TFP22O Page 3 of 8 Hazard Type Temperature Bulb Liquid Sprinkler Finisha Natural Brass I Chrome Plated Polyester° I J Lead Coated Upright K=11.2 (TY5137) 135 OF (57 °C) Orange 1, 2, 3C, 4 155 IF (68 °C) Red 175 OF (79 °C) Light Pendent Yellow 200°F (93 °C) Green 1, 2, 4 Table B describes UL and c-ut K=11.2(1Y5237) K=14.0 (TY6237) 286 IF (141 °C) Blue Recessed Pendent K=11.2 (TY5237) K=14.0 (TY6237) 135 IF (57 °C) Orange 1,2,3,4 Sensitivity Rating Table C describes FM Sensitivity Rating 155 IF (68 °C) Red 175 IF (79 °C) Yellow With Style 30 Escutcheon 1, 2, 4 I N/Ad 200 IF (93 °C) Green 286 °F(141 °C) Blue Upright 135 IF (57 °C) Orange 155 IF (68 °C) Red Ordinary Table B describes K11.2 (TY5137) K14.0 (TY6137) Pendent K=11.2 (TY5237) 1,2,3,4 175°F(79°C) Yellow 200 IF (93 °C) Green UL and C-UL Sensitivity Rating K=14.0 (TY6237) 286 IF (141 °C) Blue Recessed Pendent 135 IF (57 °C) Orange Table C describes 155 IF (68 °C) Red FM Sensitivity Rating K=11.2 (1Y5237) K=14.0 (TY6237) With Style 30 or 40 1, 2, 4 I N/A 175 OF (79 °C) Yellow 200 OF (93 °C) Green Escutcheon NOTES Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratoies, Inc., for use in Canada (C-UL) Approved by Factory Mutual Corporation (FM) Approved by the City of New York under MEA 177-03-E Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed as Corrosion Resistant Sprinklers. Frame and Deflector only Pendent only N/A = Not available TABLE A LABORATORY LISTINGS AND APPROVALS Light Hazard Ordinary Hazard Area Style ftxft 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57 °C) (68 °C) (79 °C) (93 °C) (141 °C) (57 °C) (68 °C) (79 °C) (93 °C) (141 °C) Upright or Pendent - - - - - OR OR OR OR OR 14 x 14 Style 30 Recessed - - - - - OR OR OR OR OR Style 40 Recessed - - - - - OR OR OR OR OR Upright or Pendent OR OR OR OR OR SR SR SR SR SR 16x16 Style 30 Recessed OR OR OR OR OR SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR OR OR OR OR SR SR SR SR SR 18 x 18 Style 30 Recessed OR OR OR OR OR SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR OR OR SR SR SR SR SR SR SR 20 x 20 Style 30 Recessed OR OR OR SR SR SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR NOTES OR = Quick Response SR = Standard Response OR and SR does not apply to Upright K=14.0 Refer to Table 0 for permitted K-Factor/Area Combinations. TABLE.B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-11 OR EC-14 SPRINKLERS TFP22O Page 4 of 8 HC-1 Linear Spacing Area Spacing ft ft Ceiling Height ft Ceiling Type Max K-factor Style Response Mm Max Mm Noncombustible Unobstructed, 11.2 EC Pendent or 10 20 100 400 Up to 30 Noncombustible Obstructed, or 14.0 EC Upright Combustible Unobstructed Noncombustible Unobstructed, 11 2 EC . Pendent 10 20 100 400 Up to 30. Noncombustible Obstructed, or 14.0 EC Recessed Combustible Unobstructed Style 30 Quick 10 20 100 400 Up to 30 Combustible Obstructed 11.2 EC EC Pendent or 14.0 Upright 11 2 EC . Pendent 10 20 100 400 Up to 30 Combustible Obstructed 14.0 EC Recessed Style 30 10 20 100 400 Over 30 and up to 45 Noncombustible Unobstructed 11.2 EC 14.0 EC Upright HC-2 Linear Spacing Area Spacing ft ft Ceiling Height ft Ceiling Type Max K-factor Style Response Mm Max Mm 10 20 100 400 Upto30 Noncombustible Unobstructed, 11.2 EC Upright 10 20 100 400 Upto30 14.0 EC Pendent or Upright Combustible Unobstructed Quick 10 16 100 256 Over 30 and up to 45 11.2 EC 14.0 EC Upright HC-3 Linear Spacing Area Spacing ft ft Ceiling Height ft Ceiling Type Max K-Factor Style Response Mm Max Mm 10 16 100 256 Up to 30 11.2 EC Upright 10 20 100 400 Upto30 14.0 EC Pendent or Upright Noncombustible Unobstructed, Combustible Unobstructed Quick 10 16 100 256 Over 30 and up to 45 11.2 EC, 14.0 EC Upright NOTES The design for K 11.2 EC (K 160 EC) sprinklers should not include fewer than six sprinklers or have a design pressure of less than 12 psi (0,8 bar); similarly the design for K 14.0 EC (K 200 EC)sprinklers should not include fewer than four sprinders or have a design pressure of less than 18 pal (1,2 bar). For flow criteria, refer to FM Loss Prevention Data Sheet 3-26. Refer to FM Loss Prevention Data Sheet 2-0 for permitted K-Factor/Area Combinations. TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-11 OR EC-14 SPRINKLERS The sprinkler deflectors are to be located in a horizontal plane at or above 1 in. (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 in. (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage upright and pendent sprinklers applies. FM Approval Requirements Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprin- klers are to be installed in accor- dance with the applicable FM Loss Prevention Data Sheet for limited use in buildings of specific roof construc- tion and for the protection of certain specific ordinary hazard (non-storage and/or non-flammable or combustible liquid) occupancies. Information pro- vided in the FM Loss Prevention Data Sheets relates to, but is not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector-to- ceiling distance. These criteria may differ from UL and/or NFPA criteria. Therefore, the designer should review and become familiar with FM requirements before proceeding with design. TFP22O Page 5 of 8 Description Area ft x ft Light Hazard 0.10 GPM/ft2 Group I Ordinary Hazard 0.15 GPM/ft2 Group II Ordinary Hazard 0.20 GPM/ft2 GPM PSI GPM PSI GPM PSI 14x14 30 7.2 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 TY5137 18 x 18 33 8.7 49 19.1 65 33.7 (K=11.2) Upright 20x20 40 12.8 60 28.7 80 51.0 14x14 30 7.2 30 7.2 39 12.1 16x16 30 7.2 39 12.1 51 20.7 TY5237 18x18 33 8.7 49 19.1 65 33.7 (K=11.2) Pendent 20x20 40 12.8 60 28.7 80 51.0 14x14 N/A N/A 39 7.8 51 13.3 16 x 16 N/A N/A 39 7.8 51 13.3 TY6137 18x18 N/A N/A 49 12.3 65 21.6 (K=14.0) Upright 20x20 N/A N/A 60 18.4 80 32.7 14x14 37 7.0 39 7.8 51 13.3 16x16 37 7.0 39 7.8 51 13.3 TY6237 18 x 18 37 7.0 49 12.3 65 21.6 (K=14.0) Pendent 20x20 1 40 8.2 60 18.4 80 32.7 NOTES 1ft=0.348m 1 ft2=0.093m2 1 GPM = 3.785 LPM 1 psi = 0.06895 bar 1 GPM/ft2 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-11 AND EC-14 SPRINKLERS Installation TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135 OF (57 °C) to 3/32 in. (2,4 mm) for the 286°F (141 °C) temperature ratings. A leak-tight 3/4 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 10 to 20 ft-lb (13,4 to 26,8 N.m). Higher levels of torque may distort the sprin- kler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler with the deflector parallel to the mounting surface. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate (or other applica- ble escutcheon) over the sprinkler pipe threads and with pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. For upright or pendent sprin- klers, wrench-tighten using only the W-Type 3 (End A) Sprinkler Wrench. For the pendent sprinkler installed with Style 30, 40, or 60 Escutcheon, wrench-tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. Apply the wrench recess of the appli- cable sprinkler wrench (Figure 5 and 6) to the sprinkler wrench flats (Figure 1). Care and Maintenance TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. TFP22O Page 6 of 8 2-7/8° DIA. 1/2±1/8 (73,0 mm) 1/2 (12,7 mm) (12,7±3,2 mm) 2-1/4 DIA. 1/4 (6,4 mm) SPRINKLER 1/8" FITTING (3,2 mm) MOUNTING MOUNTING SURFACE ___________ CLOSURE PLATE . 1.3/8(34,9mm) 1-1/8 (28,6 mm) FIGURE 2 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 IN. TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8 DIA. 5/8±1/4 (73,0 mm) - 3/4' (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4(6,4mm) FACE OF - (57,2 mm) SPRINKLER 1/8° FITTING (3,2 mm) - .. _fJ MOUNTING MOUNTING /7 SURFACE PLATE / _______ (34,9 mm) CLOSURE 7/8 (22,2 mm) FIGURE 3 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FACE OF SPRINKLER FITflNG: 3/8° (9,5 mm) ABOVE TO 1/8' (3,2 mm) BELOW MOUNTING SURFACE I tjlll~ ESCUTCHEON PLATE - SEATING SURFACE: 1/4' (6,4 mm) ABOVE TO 1/2 (12,7 mm) BELOW MOUNTING SURFACE; 3/4" (19,1 mm) TOTAL ADJUSTMENT Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost MOUNTING 1/8' SURFACE (3,2 mm) CLOSURE 3/4, NPT 25/16 (58,7 mm) -MOUNTING 1-13/16" (46,0 mm) PLATE liquid from its bulb. Refer to the Instal- lation section, for more information. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. 2-7/8 DIA. (73,0 mm) 2-1/4° DIA. (57,2 mm). J. INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE IRON REDUCING SPRINKLER FITTING "FITTING SIDE" TOWARDS SPRINKLER FITTING /\ WRENCH RECESS / (END "A") FIGURE 5 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS - 1i \ ri WRENCH HEX FIGURE 6 W-TYPE 22 RECESSED SPRINKLER WRENCH FIGURE 4 SERIES EC-11 AND EC-14 PENDENT SPRINKLER ASSEMBLY WITH 3/4 IN. TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON TFP22O Page 7 of 8 P/N 51 - XXX - X - XXX I SIN R j S FINISHI TEMPERATURE RATING 893 11.2K Pendent 1Y5237 1 NATURAL BRASS 135 135°F(57°C) 894 11.2K Upright 1Y5137 SIGNAL WHITE 155 155 °F (68 °C) - POLYESTER 895 14.0K Pendent TY6237 JET BLACK (RAL9005) 175 175 °F (79 °C) - POLYESTER 896 14.0K Upright TY6137 - 200 200 °F (93 °C) 7 LEAD COATED 286 286 °F (141 °C) 9 CHROME-PLATED - - 000 OPEN2 NOTES: Escutcheon ordered separately. OPEN indicates the sprinkler assembly without glass bulb, button, and sealing assembly. TABLE SERIES EC-11 AND EC-14 UPRIGHTAND PENDENT SPRINKLERS PART NUMBER SELECTION The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this doc- ument, as well as with the applicable standards recognized by the Approval agency, such as NFPA 25, in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series EC-11 or EC-14 (specify) Sprinkler, SIN (specify), (specify) K-factor, Pendent or Upright (specify) Extended Coverage, (specify) temperature rating, (specify) finish, P/N (from to Table E) Recessed Escutcheon, Two-Piece Specify: Style (30 or 40) Two-Piece Recessed Escutcheon with (specify) finish, P/N (specify*) -- Refer to Technical Data Sheet TFP770 Flush Escutcheon, Two-Piece Specify: Style 60 Two-Piece Flush Escutcheon with (specify) finish, P/N (specify**) **Refer to Technical Data Sheet TFP778 Sprinkler Wrenches Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001 TFP22O Page 8 of 8 1400 Ponnbrook Parkway, Lansdale, PA 194461 Telephone +1-215462-0700 C 2018 Johnsen Controls. All rights renamed. All specifications and other Information shown were current as of document revision date and are subject to change wllhOst notice. Johnson 0) )Vo NATIONAL FIRE PROTECTION ASSOCIATION and NFPA Ore registered trodamarkn of ReSend Fire Protection A0005lallon; Controls TEFLON no retictored Paderrrarkaf Dupont