HomeMy WebLinkAbout2622 GATEWAY RD; 115; FPC2019-0015; Permit(ity of PERMIT REPORT Carlsbad Print Date: 03/02/2022 Permit No: FPC2019-0015 Job Address: 2622 GATEWAY RD, # 115, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132621900 Track #: Applied: 01/29/2019 Valuation: $159,901.38 Lot #: Issued: 02/22/2019 Occupancy Group: Project #: Finaled Close Out: 05/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: KBS GOLF SHAFTS - 2 NEW INPUT MODULES FOR SPRINKLER MONITORING FPContractor: RIVER FIRE AND SECURITY INC 8920 ACTIVITY RD, # STE SAN DIEGO, CA 92126-4458 (858) 752-6250 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1760-602-8561 f I www.carlsbadca.gov DPG Submittal Package for: KBS Golf Shafts, The Square at Bressi Ranch, Bldg F 2fL- 2656 Gateway Road Suite 435 Carlsbad, CA 92009 River Fire and Security 8920 Activity Road, Suite J San Diego, CA 92126 Contains Cutsheets and CSFM Listings for: EXISTING Fire Alarm Control Panel Input Module FPC20190015 #115 2622 GATEWAY RD KBS GOLF SHAFTS -2 NEW INPUT MODULES FOR SPRINKLER MONITORING 2132621900 1/2912019 FPC20190015 12/26/2018 0 I FP-75 B Honeywell I Farenhyt Series Intelligent Fire Alarm Control Panel IFP-75 / FP-75B The IFP-75 (red) and IFP-75B (black) are intelligent analog/ addressable Fire Alarm Control Panels (FACP). IFP-75 has a single line circuit (SLC) loop for connecting addressable detectors, which can support 75 IDP/SK sensors and 75 IDP/SK modules or 7550 devices per loop. For System Sensor devices the overall point capacity to a maximum of 150 points per panel, or for Hochiki devices the overall point capacity to a maximum of 75 points per panel. IFP-75 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. To network panels together use the SK-NlC network interface card. Copper wire or fiber optic cable panel connectivity can be used within the same networked system. IFP-75 has a built-in dual-line digital and I P communicator with an optional cellular communication module, Form C trouble relay, and two programmabLe Form C relays. IFP-75 has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert. The lFP-75 supports a variety of devices, including RA- 2000, RA-1000 or RA-100 remote annunciator, 5824 serial/ parallel printer interface module (for printing system reports), RPS-1000 power module, and IDP, SK or SD devices. FEATURES & BENEFITS Network support for up to 32 Sites Built-in support for up to 75 IDP/SK detectors and 75 IDP/SK modules or 75 SD SLC devices Four line LCD display with 40 characters per line Available in a red or black cabinet IFP-75 can be surface or flush mounted Built-in USB interface for programming Programmable date setting for Daylight Saving Time JumpStart AutoProg ramming' feature for easy programming Built-in dual phone line, digital alarm communicator! transmitter (DACT), IP or optional cellular technologies Network card allows copper network connection with a multi-mode or single-mode fiber connection option Firmware can be upgraded in the field Supports up to four SWl FT wireless gateways. Each gateway can have up to 49 wireless devices Supports Class B (Style 4) and Class A (Style 6 or Style 7 configuration for SLC. and SBUS Built in synchronization for appliances from AMSECO, Gentex. System Sensor', and Wheelock Reports events to central station by point or by zone FP-75 Technical Specifications SPECIFICATIONS Physical: Overall Dimensions: 15.12' H x 12.71W x 3.33" D Weight: 25 tbs. Color: Red or Black Environmental Operating Temperature: 32'F to 120°F (0°Cto49°C) Humidity: 0 to 93% relative humidity (non- condensing) ELECTRICAL: IFP-75 Primary AC: 120 VAC @60 Hz, 900mA Total Accessory Load:2.5A @27.4 VDC power-limited Standby Current: 165 mA Alarm Current: 310 mA Battery Charging Capacity: 7 to 35 AH Battery Size: 7 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70,& NFPA 72: central Station; Remote Signalling: Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service Other Approvals: UL Listing; CSFM (pending); COA (pending); OSHPD (CA) (pending), FM (pending) APPROVED RELEASING SOLENOIDS Asco T821OA107 24VDC 3Amax 0 H Asco 8210G207 24VDC 3Amax 0 H COMPATIBLE DEVICES Seethe data sheets listed below fora complete listing of the IDP, 5K, SWIFT or SD devices. 350361 - IDP Device Protocol data sheet 53623 - SK Device Protocol data sheet 350360- SD Device Protocol data sheet 351615 & 351617- SWIFT devices ORDERING INFORMATION IFP-75 - Intelligent Fire Alarm Control Panel. Red IFP-75B - Intelligent Fire Alarm Control Panel Black SBUS ACCESSORIES RA-2000, RA-1000, RA-1000R, RA-100, RA-2000GRAV - Remote annunciators. RPS-1000 - Power Supply 5496- NAC Expander 5824- Serial/Parallel Module 5880- LED I/O Module 5865-3/-4 - LED Annunciator 5883 - Relay Interface MISCELLANEOUS ACCESSORIES SKSS-3 - Software Suite. Provides programming, upload/download and event reporting RBB - Remote Battery Box Cabinet. Use for backup batteries up to 35 AH. Dim: 16" W x 10" H x 6" D SK-SCK - Seismic Compliance Kit SK-NIC - Network Interface Card SK-NIC-KIT - Network Interface Card in Cabinet SK-FML- Multi Mode Fiber Card SK-FSL - Single Mode Fiber Card CELL-MOD - Cellular Communicator in Plastic Enclosure CELL-CAB-SK - Cellular Communicator in Metal Enclosure with lock and key For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. All other trademarks are the property of their respective owners. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover alt specific applications or anticipate all requirements. All specifica:ions are subject to change without notice. For Technical Support, Please call 800-446-6444. For more information www.farenhyt.com Honeywell 12 Clintonville Road Northford, CT 06472 800-328-0103 www.farenhyt.com Doc 351605 1 Rev A I 03/17 02017 Honeywell international Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0503 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Silent Knight Model lFP-75, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model IFP-75 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-N IC Network Inerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16'WX10'HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: 120VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0503 Page 2 of 2 indicating devices. Refer to listee's Installation Instruction Manual for details. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SILENT Farenhyt KNIGHT by Honeywell IDP-Minimon Agency Listings The IDP-Minimon is a compact and light weight addressable monitor module for use with Silent Knight IFP-series fire alarm Ut M EA control panels (FACPs). The IDP-Minimon acts as an interface to 457-99-E Vol. V contact devices, such as waterfiow switches and pull stations. The IDP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. -- - Wq Features Single contact monitor Small and lightweight size allows for flexible mounting options Support for Class B wiring Fully supervised IDP-Minimon Rotary address switches for fast installation Analog communications Compatibility The IDP-Minimon is compatible with the UL Listed following FACPs: Installation • IFP-2000 I RPS-2000 Intelligent Fire The IDP-Minimon can be mounted in a single gang junction box Panel directly behind the monitored device. Its small size and light • IFP-1000 / ECS Intelligent Fire Panel weight allow it to be installed without rigid mounting • IFP-100 I ECS Intelligent Fire Panel requirements. • IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350279 Rev F Copyright © 2013Honeywell International Inc Other Devices Wiring the IDP-Minimon Specifications Physical Height: 1.3" (3.3 cm) Width: 2.8" (7 cm) Depth: 0.5" (1.3 cm) Shipping Weight: 1.2 oz (37 g) Electrical Operating Voltage: 15— 32 VDC Standby Current: 375 pA; 600 pA max (communicating, IDC shorted) End-of-Line Resistance: 47K Initiating Device Circuit Wiring Resistance: 1,5002 max SLC Loop Resistance: 402 max. Wire Length: 6" mm. Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information IDP-Minimon Miniature Monitoring Module ] SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, IDP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, 5K-Zone monitor modules, IDP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDPRELAYMON.2 *SKRELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division