Loading...
HomeMy WebLinkAbout2382 FARADAY AVE; 250 | 275; FPC2018-0380; Permit(city of PERMIT REPORT Carlsbad Print Date: 03/22/2022 Permit No: FPC2018-0380 Job Address: 2382 FARADAY AVE. CARLSBAD, CA 92008-7221 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Track #: Applied: 11/21/2018 Valuation: $0.00 Lot #: Issued: 12/05/2018 Occupancy Group: Project #: Finaled Close Out: 02/07/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: ONE CARLSBAD RESEARCH CENTER -SPRINKLER TI (95 HEADS) SUITES 250 & 275 Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov (ITAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS TER SUITE 250 & 275 2382 Faraday Avenue Carlsbad, CA 92008 FPC20I8-0380 2382 Faraday AVE ONE CARLSBAD RESEARCH CENTER - SPRINKLER TI (95 HEADS) SUITES 250 & 275 121412018 - F!c20180380 FireLock® V38, K5.6 Models V3801, V3802 Adjustable Concealed Standard Spray Standard and Quick Response V3801 and V3802 Approvals/Listings: LPCB LISTED 0832 104-la/02 See Victaulic Publication 1001 for more details. Product Description: This concealed, designer style sprinkler allows up to 1/2713 mm adjustment to accommodate concealment needs. The 'standard" design provides a consistent hemispherical spray pattern. The separate two-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. Coverage: For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. \4tauljcr 40.50 Technical Specifications: Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard, light hazard Nominal Orifice Size: '/2/13 mm K-Factor: 5.6 Imp./8.1 SI.1 Nominal Thread Size: 1/2715 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3. 1 For K-Factor when pressure is measured in Bar, multiply Si. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 40.50 2558 Rev. 0 updated 07/2014 © 2014 victaulic company. All rights reserved. 1 X.0 AC —ta _U1 i e victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Ll Material Specifications: Deflector: Bronze per UNS C22000 Cover Plate: Fusible solder Bulb: Glass with glycerin solution. Bulb Nominal Diameter: LI Standard: 5,0 mm LI Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Stainless steel per UNS S30100 Seal: Teflon2 tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene Accessories: Installation Wrench: LI Concealed: V38-4 or V38-5 Sprinkler Finishes: LI Plain Brass (only) Cover Finishes: El Chrome Plated L White Painted3 LI Flat Black Painted3 LI Custom Painted3 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 JtauIic victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Approval/Listings: Approvals/Listings Model hf' V3801 V3802 Orifice Size (inches) 1/2" 1/2" Orifice Size (mm) 13 13 Nominal 1< Factor Imperial 5.6 5.6 Nominal K Factor S.l. 8.1 8.1 Response Standard 5mm bulb Quick' 3mm bulb Defiectorlype Concealed Pendent Concealed Pendent Adjustment Approved Temperature Ratings F°/C V3801 V3802 135 F/57 C 135 Ff57 C cULus 155 Ff68 C 155 F/68 C 175 F179 C 175 Ff79 C 200 Ff93 C 200 Ff93 C 155 F/68 C4 FM5 NONE 175 F/79 C4 200 Ff93 C4 135 Ff57 C 135 Ff57 C NYC/MEA5 #62-99-E 155 Ff68 C 155 Ff68 C 175 Ff79 C 175 Ff79 C 200 Ff93 C 200 Ff93 C 135 Ff57 C 135 Ff57 C CSFM5 #7690-0531:112 1 55 F/69C 155 Ff68 C 175 F/79 C 175 Ff79 C 200 Ff93 C 200 Ff93 C 155°F/68°C Sprinkler/i 38°Ff59°C Cover 155°Ff68°C Sprinkler/1 38°Ff59°C Cover LPCB 175°Ff79°C Sprinkler/1 65°F/74°C Cover 175Ff79C Sprinkler/1 65Ff74C Cover 200°F/93°C Sprinkler/1 65°Ff74°C Cover 200°Ff93C Sprinkler/165'F/74'C Cover 135 Ff57 C 135 Ff57 C 155 Ff68 C 155 Ff68 C VNllPO 175 Ff79 C 175 Ff79 C 200 Ff93 C 200 Ff93 C 286 Ff141 C 286 Ff141 C CCCf ZSTDY NONE 155 Ff68 C For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. 5 Recognized by FM as standard response only. Note: Listings and Approvals as of printing. All are approved open. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 3 '.J(tauIic 2%'/71 mm ½713 mm Adjustment 3¼/es mm Coxes Plate Maximum Extension 2/51 mm Typical Ceiling Tile - Finished Surface victaulic.com I Sprinkler I FireLock I K5.6, V38 I Publication 40.50 Dimensions: Models V3801, V3802 (drawings not to scale) 251r'/68 mm Max. Hole 2W/HO mm Mm. Hole 2W159 mm 1~2 "I I lbp~ mm Typical Ceiling Tile Finished Surface Minimum Extension 3'A'/eO mm Distribution Patterns: Models V3801, V3802 K5.6 standard concealed pendent distribution patterns - trajectory 10' 3.0 m j * -- 4 8' 2.4m 4 6' 1.8m - 4' 1,2m 0.6m 0 1111111 0.6 m 1.2 m 1.8m 2,4 m 3.0 m 3.7 m 43 m 7ps1 _.._. 15 psi 30 psi ....... 48kPa 103kPa 207kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 4 \JtauIic victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Ratings: All glass bulbs are rated for temperatures from -670F/-55°C to those shown in table below. Sprinkler Sprinkler - V3801, V3802 Cover - V38 Temperature - Ft C Temperature - F/ C Nominal Maximum Ambient Nominal Maximum Ambient Temperature Victaulic Part Temperature Temperature Victaulic Part Temperature Temperature Classification Identification Rating Allowed Glass Bulb Color Identification Rating Allowed Ordinary A 135 F/57 C 100 F/38 C Orange A6 1358 57 100 57 Ordinary C 155 Ff68 C 100 F/38 C Red D7 165 74 150 65 Intermediate E 175 Ff79 C 150 Ff65 C Yellow Intermediate F 200 Ff93 C 150 Ff65 C Green High J 286 F/141 C 225 F/107 C Blue Extra High 8 K 360 F/182 C 300 Ff149 C Purple - M Open - No Bulb 6 A For use with Standard or Quick Response Concealed Sprinkler 135°F/57°C or 155°F/68°C. D For use with Standard or Quick Response Concealed Sprinkler 175F/79C or 200F/93C. 8 138°F/59°C per LPCB Note: Custom Finish - Customer to provide paint specification, allow 4 - 6 weeks for samples. Available Wrenches: Sprinkler Type Recessed Concealed Pendent - V3801, V3802 V38-4 or V38-5 40.50 2558 Rev. 0 updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 5 \,4tauIic victaulic.com I Sprinkler I FireLocktm I K5.6, V38 I Publication 40.50 WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. O Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Installation Reference should always be wade to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.sictaalic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic and Zero-Flex are registered trademarks of Victaulic Company. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic company. All rights reserved. ictaulid victaulic.com 6 FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response V2703/V2704 V2707/V2708 V2707/V2 708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to I4/19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. JtauIicr 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½' NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock'Th I K5.6, V27 I Publication 40.10 40.10 2544 Rev. j updated 07/2014 0 2014 victaulic company. All rights reserved. 1 4tauIici victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS 011000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: Eli Standard: 5.0 mm P1 Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS 065100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: P1 Open End: V27 P1 Recessed: V27-2 Sprinkler Finishes: P1 Plain Brass P1 Chrome plated P1 White painted3 P1 Black painted3 Eli Custom painted3 1:1 Proprietary Nickel Teflon2 coating3 P1 VC-2504 155, 200, 286 SR Only: P1 Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 2 '/(tauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model P P APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C cULus 1757/79°C 175°F/79°C 175°F179°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286° F/i 41°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57'°C 155°F/68°C 155°F/68°C 135°F/S 7°C FM 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/1 41°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 3607/1 82°C 360'F/1 82'C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C NYC/MEA 62-99-E 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286° F/i 41 °C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141 °C 286°F/1 41°C 286°F/141°C 286°F/141 °C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93°C 360°F/1 82°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C .. 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/1 82°C 360'F/1 82'C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93°C 2007/93°C 200°F/93°C 135°F/57°C 155°F/68°C VdS 175°F/79°C None None 175°F/79°C None None 200°F/93°C 286°F/141°C 360°F/1 82°C 135°F/57°C 155°F/68°C CE 175°F/79°C None None 175°F/79°C None None 200°F/93°C 286°F/141°C 360°F/1 82°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 ,,/tauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: 2 60 1W! 2W! 41 mm 60 mm 1'Aa/ 37 mm Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/60 mm Max. Hole 2/51 mm Mix Hole 17 mm Typical Ceiling Tile 11 30m 1 XC! Finished Surface 30nm 43 mm MAXIMUM RECESS 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 25'a7bu mm Max. Hole 2751 rn Finished Surface 24,nnn MAXIMUM RECESS 215A6"/ 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 './tauIic 'I•• 1 01 3.0m 8' 2.4m 6' 1.8m 4' 1.2m 2' 0.6m 7 psi 48 kPa 15 psi 103 kPa 30 psi . 207 kPa victaulic.com I Sprinklers I FireLock8 I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent 10' 3.0n 8' 2.4m 4' 1.2m 2' 0.6m 7 psi 48 kPa 15 psi 103 kPa 30 psi - 207 kPa 2' 4 6' 8' tO' 12' 14' 0.6,,, I.2n 1.8n, 2.4, 3.om 3.7m 4,3m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory 2' 4' 6' 8' 10' 12 14' 16' 0.6m 1.2m 1.8,,, 2.4,,, 3.om 3.7m 4.3,,, 4.9,,, NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 5 JtauIicr victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - Fl C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 F/38 C Orange Ordinary C 155 F/68 C 100 F/38 C Red Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F8/107 C Blue Extra High K 360 F/182 C 300 F/149 C Purple - M Open - No Bulb Standard response Only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707,V2708Pendent V2707,V2708 Recessed Pendent V2703,V2704 Upright A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. I WE Installation Note Reference should always be wade to the 1-40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Sheet for the product you are installing. This installation sheet lobe installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and is available in POE format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 \,4'tauIic Bull Moose Tube'sO Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tubes made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube'se Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED APPROV8I ONFSA NFPA' 4 NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 - 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS - NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 2:1/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 'Only available in Casa Grande, AZ "Corrosion Resistance Ratio per latest Ut. Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. I> A A For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road U Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas, TX Masury, OH 63017 Dull Moose Tube's Eddythread 40 ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 40® I.) is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 110 MIC preventative coating. EDOVTHREAD 40® SPECIFICATIONS c®us LISTED NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB/FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROtOO I] 4 ONMA NFPX -==- For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ DallasjX MasutK OH 63017 Bull Moose Tubes® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM Al 35 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APPROVED I]4 NFM NFPA' 6 ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL PIPE SIZE (IN) STANDARD O.D. (IN) INSIDE DIAMETER (IN) UL THREADED UL UNTHREADED WEIGHT PER FT. WATER FILLED BUNDLE SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 corrosion Resistance Ratio per latest UI Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent,wA Casa Grand AZ Dalla4 D( Masuix OH ooecn,ae 63017 c®us LISTED ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD Il® MIC preventative coating. NPS O.D. SIZE (IN) (IN) EDDY FLOWO (ID) EDDY FLOWS CRR* WEIGHT PER FT. WATER FILLED WI. BUNDLE SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 1-1/2 1.900 1.728 3.44 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 11.290 19 'Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas DC Masunj. OH 63017 7 Bull Moose Tube's® Eddy Flow® is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's® larger ID provides an opportunity for downsizing and further cost savings. IsPPRlIV8J COM] *Al:: ONM NFPK •-'-- Dull Moose Tubes® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® I) a versatile product that can be Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WI. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 Pressfit is a Registered Trademark of Victaulic company of America Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED APPROVOI [;;] 4 ONFU NFPX 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q ® For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande. AZ Dallao,TX Masutry, OH r.a.ou,cc,env 63017 NPS (IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 c®us LISTED APPR0VUJ NFPA' 0.0(m) 1.315 1.660 1.900 2.375 ID (in) 1.201 1.546 1.786 2.261 ULTRA EDDY' Empty Weight (Ib/ft) 0.868 1.107 1.274 1.604 Water Filed Weightfb/ft) 1.359 1.920 2.360 3.344 - C.R.R.217 140 111 100 1.660 1.900 2.375 2.875 3.500 4.500 lD(in) 1.530 1728 2.203 2.705 3.334 4.310 Empty WeightlWft) 1.222 1.844 2.330 2.809 3.361 4.968 EDDY FLOW' Water-Hued Weight (lb/It) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 O.D.(in) 1.315 1.660 1.900 2.375 2.875 3.S00 4.500 LD.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE Empty Weight (lb/ft) 1,410 1.810 2.090 2.640 3.530 4.340 5.620 Water-Filled Weight (lb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 - j CR8 1527 991 776 627 492 354 250 0.D.(in) 1.315 1.660 1.900 2.375 ID. fin) 1.137 1.482 1.712 2.177 EDDYLITE' Empty Weight (lblft) 1.260 1.617 1.967 2.617 Water-filled Weight (lb/ft) 1.700 2.364 2.965 4.230 Jr CAR 013 008 012 016 00.(in) 1.295 1.650 1.900 2.375 ID (in) 1.083 1.418 1.645 2.123 LEDDYTHREAD ErnptyWeightfb/ft) 1.461 2.070 2.547 3.308 40' Water.HtedWeight (Ib/ft) 1.860 2.754 3.468 4.842 A.R. 1.00 1.00 1.00 1.00 0.0.(iin) 1 1.315 1.660 1.900 2.375 2.875 3.500 4.500 La (in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE Empty Weight (lb/It) 1.680 2.270 2.720 3.660 5800 7.580 10.800 40 Water-Filled Weight (Ib/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas TX Masury, OH 63011 9 c®us LISTED APPR0VB [;] 4f4 NFPA •'---- 10 NIPS PIPE TYPE WEIGHT PER FOOT PIECES PER BUNDLE WEIGHT PER BUNDLE WEIGHT PER BUNDLE WEIGHT PER BUNDLE ULTRAEDDY 0.868 91 1,659 1,896 1,975 SCHEDULE 10' 1.410 91 2,695 3,079 3,208 1 EDDyLITEe 1.260 91 2,408 2,752 2,867 :EDDYTHREAD 400 1.461 70 2,148 2,454 2,557 SCHEDULE 40 1.680 70 2,470 2,822 2,940 ULTRA EDDYO 1.107 61 1,418 1,621 1,688 EDDY FLOW 1.222 61 1,565 1,789 1,864 SCHEDULE 10 1.810 61 2,319 2,650 2,760 11(4 EDDYLITEe ' 1.617 61 2,071 2,367 2,466 EDDYTHREAD4O 2.070 51 2.217 2.534 2,639 SCHEDULE 40 2.270 51 2,431 2,778 2,894 ULTR.AEDDY 1.274 61 1,632 1,865 1,943 EDDYFL0W 1.844 61 2,362 2,700 2,812 SCHEDULE 10 2.090 61 2,677 3.060 3,187 11 2 EDDYLITE0 1.967 61 2,520 2,880 3,000 EDDYTHREAD 400 2.547 44 2.353 2.690 2.802 - SCHEDULE 40 j 2.720 44 2,513 2,872 2.992 ULTRA EDDY' 1.604 37 1,246 1,424 1,484 EDDYFL0W 2.330 37 1,810 2,069 2,155 SCHEDULE 10 2640 37 2051 2,344 2,442 2 EDDYLITE6 2.617 37 2,033 2,324 2,421 LEDDYTHREAD40 3.308 30 2,084 2,382 2,481 SCHEDULE 40 3.660 30 2,306 2,635 2,745 EDDY FLOW' 2.809 1,770 2,022 2,107 2-1(2 SCHED(JLE10 3.530 30 2,224 2,542 2,648 SCHEDULE 40* 5.800 3,654 4.176 4,350 EDDY FLOW 3.361 1,341 1,533 1,596 3 SCHEDULE 10 4.340 19 032 1,979 2,062 L SCHEDULE 40 7.580 3,024 3456 3 601 EDDY FLOW 4.968 1,982 2,265 2,360 4 SCHEDLJLE10 5.620 19 2,242 2,563 2,670 SCHEDULE40* 10.800 4,309 4,925 5,130 ['6 SCHEDULE10 9.289 10 1,951 2,229 2,322 8 j SCHEDULE 10 16.940 7 2,490 2,846 2,965 * Only Available in Casa Grande, AZ. Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace spacing* Size 20 ft 25 ft. 30 ft. 35/f. 401t. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 1361 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1 1012 1 867 1 726 1 40 1 40 1 40 1 40 1 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Mx Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing ( ft.) *** According to HLF for the 2006 & 2009 BC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. F25ft. 30 ft. 35 ft. 40/f. 0.25 0.50 1 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 1 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 () BULL. MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED APPROVED no A ON4 NFPA For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com J 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande AZ Dallas, TX Masurt OH 63017 11 MechanicaIT® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date www.victaulic.com vlclAuuc IS A REGISTERED TRADEMARK OF VICTAC COMPANY. 0 2017 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV_N '%J1taUIiC 11.02_i CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Dimensions Weight Each 2 50 ½ (a) 15 920N 500 1.50 3450 38.1 2.00 51 2.53 64 - 1.61 41 5.35 136 2.75 70 3.1 1.5 - 1/4(a) 920N 500 1.50 1.97 2.53 1.61 1 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - + 1 (a) N 500 1.50 1.85 2.53 1.61 I 5.35 2.75 3.0 25 3450 , 38,1 4- 47 64 I 41 136 70 1.4 - 11/4 (a) to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 S 52 70 - 76 - 41 136 -. 76 + 1.7 - 1.5 1½ (a) to 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 500 1.50 52 2.21 70 2.74 ( 79 41 1.82 136 5.64 83 - I 2.75 1.7 -- 3.0 1.5 - 2½ ½ (a) §o 65 15 ' 3450 38.1 56 70 I - 46 . 143 70 1.4 - -1--- 4 - '/4 (a) 5o 500 1.50 2.18 2.74 j 1.82 5,64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 - 1(a) 5° 't•-' .--.t ,---. 2 N 500 1.50 2.06 2.74 1.82 ____5•_ 5.64 I 2.75 . 2.9 25 3.00 1¼ t (a) ° 500 1.75 2.30 920N 3.25 1.82 6.29 3.00 I 3.5 3.2 32 3450 44.5 . 58 j, 76 83 46 . 160 76 1.7 1.5 1½ t (a) a 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 920N 3450 50.8 300 1.50 58 2.22 76 2.75 83 46 2.25 159 j 6.46 ._4. 83 3.18 1.7 3.9 I 1.6 ½ (a) 76.1 x 15 2065 1 38.1 56 70 - 57 164 81 1.8 1/1 (a) 300 1,50 2.19 2.75 2.25 ..... 6.46 3.18 3.9 20 N 2065 .H5 57:164 81 1.8 1(a) 920N 300 1.50 J 2.07 2.75 2.25 6.46 3.18 3.8 - 25 1¼ (a) ° 920N 2065 38.1 500 1.75 1 53 2.30 70 3.00 ...... 3,31 .. 1.92 6.29 j 3.00 3.5 ' 3.2 32 3450 44.5 58 76 84 49 160 , 76 1.6 1.5 11/2 (a) a 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 2 N 9 0 920 N 3450 5118 4 500 1.50 58 2.52 76 3.05 84 49 2.28 160 6,15 83 2.75 1.6 3.4 1.5 3 ½ (a) a 80 15 so , 382 64 78 - 58 156 70 , 1.6 - 'A (a) a 920N 500 1.50 2,49 3.05 2.28 6.15 2.75 3.4 - 20 3450 38.1 63 78' - 58 156 ,j 70 j, 1.6 1(a) 20¼ 500 iso T 2.38 3.06 2.28 6.15 2.75 3.3 - 25 3450 38,1 61 78 58 156 70 1.6 11/4 (a) to 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 920N3450 44.5 65 83 90 58 !i. 1½ (a) to 920N 500 ' 2.00 2.78 3.50 3.56 2.28 6.15 -_ 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1 1.8 2 (a) a 500 2.50 920N 2,75 3.50 3.56 2.28 6.75 3.88 4.9 I 4.6 50 3450 63.5 - + _---t -_-. 500 2.50 70 -..'.-- 3.00 89 90 3.75 ..,---_-±--.-.-,-- 58 2,44 172 6.72 99 3.88 2.3 .- ) 2.1 3.8 3½ 2 X 90 50 920N 3450 63.5 1 76 - 95 1 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). f Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 2W BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. DIMENSIONS A;. A AN GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2I50 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com J'tEuuic viclAuLic IS A REGISTERED TRADEMARK OF vicTAuuc COMPANY. 0 2017 vicTAulic COMPANY. ALL RIGHTS RESERVED. 11.022 REV_N DIMENSIONS Y r-r_ z 6- - ~wl i, t GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 47200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Size Style No. Max.Wo,k Pressure@~ Dimensions Weight Approx. Each =Min am GM MD am TABLE CONTINUED FROM PAGE 2 4 14(a) a 920N 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 100 15 a 3450 38.1 77 90 t 68 178 2.69 7.01 70 2.75 1.8 - 34(a) 20920N 500 1.50 3.00 3.56 3.7 .1 345038176 0j 1.8 1(a) a 920 500 1.50 2.88 3.56 ) 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 - 1 ¼ (a) to 2 N 500 . 1.75 - 3.08 -( 3.78 I 4.00 - 2.69 7.01 -- 3.00 4.0 4 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2 (a) to 920¼ 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 .-- 68 178 83 2.0 I 1.9 2 (a) to 500 2920N.50 3.25 4.00 4.00 I 2.69 7.01 3.88 5.0 4.6 50 3450 . 63.5 83 102 102 I 68 178 99 2.3 I 2.1 2½ (a) t 920 500 2.75 2.88 4.00 4..-.........-...~-±.--,.-.-. 4.00 I 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 1 73 - 102 . - I 68 186 . . I 118 t - . 2.9 - 3(a) t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 I 3450 88.9 84 t - .. - .3. - H- 114 105 68 1 196 130 3.8 I 2.9 2.63 1 7.64 ... 3.05 - 5.0 11/4 (a)a 108.0 X 920N j 500 1.75 3.08 3.78 32 3450 44.5 78 96 - 67 194 78 1 ½ (a)a 920N 500 2.00 3.28 4.00 - 2.63 7.64 3.25 5.0 I - 40 2 (a) 3450 500 50.8 2.50 83 3.25 102 + 4.00 67 + 194 2.63 7.64 83 I t 4.00 2.3 4.0 50 920N 3450 63.5 83 . 102 - 67 194 102 76.1 mm 500 2.75 2.88 ....-r -.r -.-...F -................. 4.00 4..00 2.63 7.64 4.29 8.0 7.8 3450 69.9 + 73 - I 102 + -+t#+ 102 67 194 I 109 3.6 3.5 3 (a) 920 500 3.50 3.31 . 4.50 4.50 2.63 7.63 4.88 . 6.8 6.5 80 3450 500 88.9 2.00 84 4.03 . 114 4.75 114 4.75 1 67 194 .. .. 3.16 9.70 124 ... 3.69 I 3.1 7.4 3.0 7.6 5 1 1/1 (a) t 920 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a) t 50 920 500 I 3450 2.50 63.5 4.00 102 4.75 I 121 4.75 121 3.16 9.70 80 246 4.38 I 111 8.2 3.7 8.0 3.6 - ---+,- -+-.r -+- -- 2½ (a) t 500 2.75 3.63 4.75 3.16 9.70 4.63 8.3 7.9 65 920 3450 69 92 121 I 121 . 80 246 118 3.8 j3.6 76.1 mm 920 500 2.75 I 4.75 3.16 9.70 4.63 8.0 3450 69.9 95 - 121 80 246 118 - 3.6 3 (a) t 2 500 .4 3.50 3.81 .......4 5.00 4.63 I ._... 3.16 9.70 5.31 8.4 8.8 80 920¼ 3450 500 88 2.50 1 97 3.75 127 4.50 118 80 1 246 3.17 8.00 3.88 8.0 2 133.0 x 50 3450 -_ 63.5 -- 95 -- 114 - - 81 203 99 3.6 920 500 3.50 3.8T 5.00 - . 3.00 9.46 5.31 8.0 80 3450 88.9 97 127 i 76 240 135 I 3.6 - TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victauliC.com .4taUIiC• viclAuLic is A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. C 2017 ViCTAuLiC COMPANY. ALL RIGHTS RESERVED. REVN 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Y z 6-1 ~f GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for. Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2 /50 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Size S'y'e No. ~ Pressure@ LMa.s I= Dimensions 9R) a• a -2 - 1 - TABLE CONTINUED _FROM _PAGE _3 1397 x 1½ t 920N 1 500 2.00 3.78 4.50 - 3.30 8.23 3.25 7.0 - 40 3450 50.8 ..2. 114 J 84 209 83 3.2 t 2 t 920N 3450 500 2.50 3.75 4.50 I -_ 3.30 1 8,23 3.88 9.0 50 920N 500 os .p 1.75 4.43 5.13 .i. .± 4 3.79 9.15 -99 - 3.25 j ±L 5.1 Il 4.8 6 1 'A (a) 5.13 150X 32(b) .. ... 1 1h (a) to 0 920N 500 2.00 4.40 5.13 I 5.13 379 9.15 3.25 5.4 . 5.1 40(b) 3450 50.8 . 112 130 I 130 96 232 83 2.4 2.3 2(a) t 500 t++t4 2.50 4.38 1 5.13 5.13 .-.+- 3.79 I 9.15 3.88 -t 6.0 I 5.6 ____ 920N50 3450 63.5 111 1 130 130 96 232 99 I 2.7 I 2.5 - +- f __f.._. - _. - - f_. 2½ 920 500 2.75 4.01 5.13 5.12 3.69 I 10.51 4.63 I 8.3 . 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 6. mm 76.1 920 500 2.75 4.15 1 5.21 3.69 I 10.51 4.63 8.4 3450 69.9 105 132 94 267 118 3.8 920 500 _._. 3.50 4.31 5.50 ....._ .,_. 5.13 _j.-_. 3.69 10.51 ... 5.31 9.9 + I 8.4 80 P SL.J4.........130 94j267 135 4.5 3 4(a) to 920 500 4.50 . 3.81- 5.75 5.38 I 3.69 10.51 6.25 10.1 10.1 100 920N 3450 500 114.3 2.00 97 4.41 146 5.13 137 94 3.63 267 9,40 159 3.25 4.6 7.8 4.6 1½ (a) 159.0 x 40 4 3450 59.8 4 50 130 112 - 92 -f - 239 I 83 F - 3.5 - - 2(a) 920N 1 500 2.50 ._ 4.38 f - 1 5.13 3.63 -'-- 9.40 1 3.88 8.0 50 3450 63.5 111 1 130 - 92 239 99 3.6 - I 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 +-+--4-+-'- 140 130 92 239 118 4.3 I 4.3 80 920 ' 500 3450 I 3.50 88.9 I 4.31 110 4 5.50 ) 140 5.13 130 3.63 92 9.40 239 I 5.31 I 135 8.1 3.7 4 14.0 1 6.4 ,--+.- .--1 ---''1 108.0mm 92Uo 500 4.50 4.45 I 5.38 ) 3.63 9.40 ) 6.12 10.0 -iLJ.. 155 j45 f 2 920 500 4.50 3.81 5.75 3.63 9.40 6.25 I 18.0 100 3450 114.3 1 96.80 146 - 92 1 239 159 1 8.2 TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services D LPCB approved for fire protection services 0 Approved for use in china by Tianjin Approvals Company. www.viCtaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. 0 2017 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. 11.02_4 ictsulicr REV...N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100mm Dimensions Weight Each ' IL i1I 4 i - im TABLE CONTINUED FROM PAGE 4 1 165,1 x 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 116 - 96 237 70 3.6 1 fl o 500 1.75 4.43 5.13 3.79 9.34 - 3.25 - 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 - -.-,,.--- 4 11/2 (a) to 920N 3450 500 2.00 4.41 5.13 5.13 3.79 934 1 3.25 I 8.4 5.4 40 . 50.8 112 130 130 96 237 83 3.8 2.4 4 - 2(a) t 500 2.50 4.38 5.13 5.13 3.79 9.34 i 3.88 8.5 . 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 I 500 I + 2.75 4.01 I 5.13 -- --------------.-- 5.21 3.63 4. 10.51 . 4.63 . 8.6 + - . 7.6 76.1 mm 920 3450 69.9 110 130 1 132 92 267 118 3.9 3.4 f_ 3(a) t 0 920 I 3.50 4.31 I 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 . 3450 88.9 C .....14......7414I4.6i3.8 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 920 3450 500 114.3 2.75 97 5.44 146 6.19 _137 6.25 92 4.81 267 I 4. ._. 4. 12.42 159 . 4.50 4.8 .. 11.6 1 3.8 4. 11.6 8 2(a) t 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 1 2½ (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 + 761 920 500 2.75 I . 525 . 6.25 4.81 12.42 4.56 11.6 _ff -3450 699 159 122 316 116 5.3 3(a) to 920 500 3.50 5.31 6.50 6.50 j 4.81 12.42 5.31 1 12.6 11.6 80 3450 88.9 135 i 165 165 I 122 316 I 135 5.7 53 1"----4 4(a) to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 . 114.3 122 171 I 162 1 122 316 1 159 6.9 1 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China byTianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victauljc.com \)#tauIic VIcTAuUc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 vlcTAuuc COMPANY. ALL RIGHTS RESERVED. REV_N 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical.T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C and KvValues Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for Cv,K, Values: ( ( J AP =Q2 Where: AID = Q2 Where: '.' c 2 Q=Flow(GPM) Q= Flow (m3/hr) I \ ,SP = Pressure Drop (psi) v = Pressure Drop (Bar) [j ) 0 = C x CV = Flow Coefficient Q = K x KV = Flow Coefficient Exaggerated for clarity ,Equivalent Length of 'Outlet Size Schedule 40 Carbon Steel Pipe .iui IaIlMy.:II. ½ 0.840 - 2 - Values I 11 15 .. . -- ... 9 - 3% 1.050 - - 16 20 26.7 13.7 1 1.315 8 I - 21 25 33.7 1 1.8 1¼ 1.660 51/2 6 50 48 32 2J . .. . 411 1 ½ 1.900 53 I 53 40 11 98.3 45.4 I 45.4 2 2.375 1 1 0% 112 104 50 603 ..- 96 ---. 89.1 21/2 65 2.875 20 12½ 73.0 — ---.__ -- 119 ..j._. 19 150 128.5 76.1 mm 3.000 161 16* - 76.1 138.1 - 3 - 3.500 15½ 1 - 2 80 88.9 14 401 213.4 203.1 4 4.500 20 22 100 114.3 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. 1 FireLocktm Innovative Groove System (IGS) outlet www.victaulic.com ictsulie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_6 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2-6 2.875 - 6.625 All 10,40 400 400 400 290 232 65-150 73.0- 168.3 1 t 2755 I 2755 I 2755 't 1999 1599 21/2 - 4 2.875 - 4,500 All 300 300 300 290 232 65-100 73.0-114.3 2.875 - 4.500 1 + All ----------- 2065 ----t 300 I 2065 -- I 300 2065 t --4- 300 . i 1999 -- 290 1599 232 21/2 -4 65-100 73.0-114.3 6.625 I - 1 2065 300 ''-- 2065 300 2065 250 1 1999 - 290 1599 -- 232 6 150 168.3 6.625 ' 3,4 30,40 I 2065 300 2065 300 I 1724 300 1999 290 . 1599 232 6 150 168,3 2065 2065 t I 2065 1 1999 1599 8 8.625 21/2 1040 400 1 145 200 219.1 8.625 3,4 1 I 2755 300 I 250 - 1000 145 8 200 219.1 8.625 - 3 ' 4 , 30 40 2065 300 - , - 1724 300 j, - 1000 145 8 200 219.1 ' 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. OF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 81100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 5'/125mm, 6/150mm and 8/200 mm diameter pipe. The Style 931 comes with a 21/2'/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com taLIlicr VICTAuLIC IS A REGISTERED TRADEMARK OF vICTAuuc COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_N 11.02_7 362 2496 362 2496 362 2496 362 2496 362 2496 MechanicaIT® STYLES 920 AND 920N INSTALLATION Reference should always be made to the I-lOU Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV UPDATED 12/2017 ictaulia VIcTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VIcTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_L FireLock® STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Pa ra Location Approved www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF viciuic COMPANY. 0 2000 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV_G JtauIicr 10.52_i IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 1 ¼ 16 1 1,30 1.83 1.10 3.87 2.56 -- 1.0 32 15 30.2 33.0 46.5 - 27 98.3 65.0 0.45 3/4 1 3/ 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 '1 1 1 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 13/16 38.6 1.42 55.4 1.95 2.9 1.22 98.3 4.08 65.0 2.56 0.54 1.2 1 ½ 1/2 40 15 30.2 36.1 49.5 31.0 , 103.6 65.0 0.54 3/4 1 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 - - 1 1 1.64 2.30 1.22 4.08 2.56 i 1.3 25 30.2 1 41.7 1.66 58.4 2.19 31.0 1.46 103.6 4.60 650 2.56 0.59 1.3 2 ½ 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 '-I- + - 3/~ 1/6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 3A6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 1956 47.8 1.91 64.5 2.44 37.1 1.71 116.8 5.40 65.0 2.56 0.68 1.6 2½ 112 65 x 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 , 3/~ 13A6 1.89 2,44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 , 1 1/i6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 1/I6 54.1 1.91 70.9 2.44 43.4 1.71 137.2 5.50 65.0 2.56 0.73 1.6 ½ 76.1 mm x 15 302 ,48.5 65.O 0.73 3/~ 1 i/o 1.89 2.44 1.71 I 5.50 2.56 1.6 20 30.2 48.0 60 43.4 L139.7 65.0 , 0.73 - 1 1 '/6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 FireLock® Outlet-T STYLE 922 DIMENSIONS I L,.II I_I .. • t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2009 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. XoAs-ta _U1 ii d 10.52_2 REV_G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. , AC_ _ta _u, i e REVG 10.523 FireLock® STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 dtauIic vicTAuLic IS A REGISTERED TRADEMARK OF VIcTAuLIC COMPANY. 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings zm• H 1'• -.).. ... a. N' T I IS FY • -- SMITH...COOPE9 INTERNATIONAL Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP - Ductile iron castings conform tc ASTM A536 c®Lus LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16A4 Fittings are 10C% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab ver:fication that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2'308 and ISO 14001 Temperature Degrees F Woikiig Pressure, Nonshock psiG 300# Class Threaded flttings -20 to 100 -50 .500 500 200 480 250 460 300 350 440 420 400 400 380 360 450 500 .550 340 320 600 650 300 Fig. 35E 3_900 Elbow COUS <~~> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35E3004 3 5 E 3006 1.13 100 70 200 140 0.2 0.3 1.31 1 - 1-1/4 35E 3010 35E 3012 35E3014 1.50 1.75 40 80 0.5 0.8 25 50 1-1/2 1.94 18 36 1.1 1.8 2 2-1/2 35E 3020 35E 3024 2.25 2.70 10 20 4 8 1 3.2 Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 35RE3010004 1.20 1.22 80 70 160 140 0.3 0.4 1 x 1/2 1.26 1.36 1 x3/4 35RE3010006 1.38 1.34 1.45 1.45 50 35 100 70 0.4 0.5 1-1/4 x 1/2 35RE3012004 1.53 1-1/4x3/4 35RE3012006 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 35RE3014004 - 1.58 1.67 30 60 60 50 0.7 0.6 1-1/2x 1/2 1-1/2x3/4 1.52 1.75 30 35RE3014006 1.52 1.75 25 0.7 1-1/2 x 1 35RE3014010 35RE3014012 1.65 -- 1.82 1.80 20 40 0.8 1-1/2x1-1/4 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 - 1.0 2 x 3/4 2x1 35RE3020006 35RE3020010 1.60 1.97 18 36 1.0 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 - 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 6 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35F 3004 35F 3006 0.88 150 300 0.2 0.3 0.5 0.98 1.13 80 160 1 35F 3010 40 80 1-1/2 35F 3012 - 35F 3014 1.29 1.44 25 50 -. 0.7 1 20 1 40 1.0 2 2-1/2 35F 3020 35F3024 1.69 10 20 1.6 2.7 1 1.95 4 8 I Fig. 35RE3 - 900 Reducing Elbow Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 3513004 35T3006 1.13 1.31 80 160 0.3 0.5 30 60 1 1-1/4 1-1/2 35T 3010 35T3012 1.50 25 50 - 0.7 1.1 1.75 10 20 3513014 1.94 10 20 1.5 2 - 2-1/2 3513020 3513024 2.25 6 12 2.4 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4 x112 lx 1/2 1x1/2x1 1 x3/4 35RT3006004 1.20 1.20 1.22 60 120 0.4 0.6 0.6 0.6 35R13010304 1.26 1.26 1.36 1.50 1.45 30 30 25 60 60 35R13010004010.50 35RT3010006 1.36 1.38 1.38 50 1x3/4x3/4 1x3/4x1 1-1/4 x1/2 35RT3010006006 1.38 1,31 1.45 1.50 1.53 35 25 20 70 50 40 0.6 0.7 35RT3010006010 1.50 1.45 35RT3012004 1.34 1.34 0.8 1-1/4x1/2x1-1/4 1-1/4 x 3/4 35RT3012004012 35R13012006 1.75 1.53 1.75 1.62 25 15 50 30 40 -0.9 -- 0.9 1.0 1.45 1.45 1-1/4x3/4x1-1/4 35RT3012006012 1.75 1.62 1.75 20 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35RT3012010004 1.34 1,26 1.53 1.63 25 20 20 50 40 40 0.7 0.8 0.9 1-1/4x1x3/4 35RT3012010006 1.45 1,38 1-1/4 x x 35R13012010010 1.58 1.50 1.69 1-1/4x1x1-1/4 1-17x1/2 35RT3012010012 1.75 1.69 1.75 15 30 32 1.0 1.0 35R 14004 1.41 1.41 1.66 1.88 16 1-1/2x1/2x1-1/4 35R13014004012 1.81 1.56 24 48 1.1 1-1/2x112x1-1/2 35RT3014004014 1.94 1.66 1.94 12 16 20 18 24 32 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.66 1.75 1.88 1.1 1.1 1.2 1-1/2x3/4x1-1/4 1-1/2x 3/4 x1-1/2 35RT3014006012 1.94 40 35RT3014006014 1.94 1.75 1.94 36 1-1/2x1 1-1/2x1x1/2 35R13014010 1.65 1.65 1.80 1.69 12 24 1.2 0.8 35RT3014010004 1.44 1.25 20 40 1-1/2x1x3/4 1-1/2x1x1 35RT3014010006 35RT3014010010 1.50 1.44 1.75 1.80 16 32 0.9 1.65 1.50 16 32 1.0 1-1/2x1x1-1/4 1-1/2x1x1-1/2 35R13014010012 1.82 1.67 1.88 12 24 24 1.2 1.3 35RT3014010014 1.94 1.80 1.94 12 1-1/2x1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 - 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35R13014012006 1.52 1.45 -1.75 16 32 1.0 1-1/2x1-1/4x1 35R13014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35R13014012012 1.82 1,75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 2x1/2 2x3/4 2x1 35R13014012014 35RT3020004 35R13020006 35R13020010 1.94 1.49 1.88 1.49 1.94 1.88 14 28 20 1.4 1.5 10 1,60 1.60 1.97 2.02 10 8 20 16 1.6 1.7 1.73 1.73 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 8 16 1.9- 2 x 11/4 35R13020012 T-90 __T_.90 210 16 1.9 2x1-1/4x2 2x1-1/2 - 35RT3020012020 2.25 2.10 2.25 8 16 2.0 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 2x1-1/2x3/4 35RT3020014004 1.49 1.41 1.88 10 20 1.3 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35R13020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35R13020014014 2.02 1.94 2.16 8 16 1.8 c .. . . . . . . . . . . . . . . . . C ceus <~~> APOVED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x 1 35813006010 1.45 1.45 1.37 30 60 0.6 1x1-1/4 35813010012 1,67 1.67 1.58 20 40 . 1 x 1-1/2 -35813010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 35813012010014 1.88 1.80 1.82 15 30 - 1.2 1.3 1-1/4x1-1/2 35813012014 1.88 1.88 1.82 15 30 1-1/4x2 35813012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 35B13014012020 2.16 2.10 2.16 2.02 2.02 10 8 20 1.8 1.8 1-1/2x2 35BT3014020 2.16 16 SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 Fig. 35CP3 - Straight Coupling with Ribs c®uS <e> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 1 35CP3004 1.38 1.63 1.75 200 100 400 200 120 0.1 0.2 0.4 0.5 35CP3006 35CP3010 60 1-1/4 35CP3012 2.00 2.19 35 25 70 50 1-1/2 35CP3014 0.7 2 35CP3020 35CP3024 - 2.62 15 30 - 1.2 2.2 2-1/2 3.00 9 1 18 Size in Part Number A in Packing Weight lb Inner Master 1 x1/2 35RC3010004 1.69 80 160 120 0.3 0.4 1 x3/4 35RC3010006 1.69 60 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (riot hex)l 35RC3020010 2.81 20 1 40 1.0 - Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x3/4 35HB3010006 1.06 -. 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35H83014010 -- 1.25 - 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2x1 35H93020010 - 1.38 - 40 80 -- 0.6 - 2x1-1/4 35H63020012 1.38 40 80 1 --80 0.6 _2x 1-1/2 35H83020014 1.38 40 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35SP3004 35SP3006 0.94 1.12 600 1200 0.07 350 700 0.1 1 1-1/4 35SP3010 -35SP3012 1.25 1.37 200 400 0.1 100 200 0.3 1-1/2 35SP3014 35SP3020 1.44 1.50 80 160 90 0.4 0.6 2 45 I r RONNIE= iv 00; 1; Fig. 35RC3 - Hex Reducing Coupling Fig. 35HB3 -Rex Bushing Fig. 35U 3- Union with Brass Seat Size in a Number A in Packing Weight lb Inner Master 1 1-1/4 35U3010 2.19 20 40 1.0 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com A A Size in Part Number A in Packing Weight lb Inner Master 1 1-1/4 35X 3010 35X 3012 1.50 20 40 24 16 0.9 -1.4 1.75 12 1-1/2 35X3014 1.94 8 1.8 2 35X 3020 2.25 6 12 2.8 ii• 11 002 ii Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C3010 1.16 110 220 0.2 -, 1-1/4 35C 3012 1.28 70 140 100 0.4 0.5 1-1/2 35C 3014 1.33 50 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Begin Clamp C Lus<~> APPROVED A A Fig. 35X 3- Cross LISTED Fig. 35RX3 - Reducing Cross Size in Part Number A in B in Packing Weight lb Inner Master 1-1/4x1 1-1/2x 1 35RX3012010 1.67 1.58 - 15 12 30 Ti 1.2 1.4 2.0 35RX3014010 35RX3020010 1.80 2.02 1.65 1.73 2 x 1 8 16 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner ] Master 3/8 - 358C3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 J 160 1 0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 INSTALLATION STEPS - !IflI, INTO WOOD & STEEL: J fINSTALLATION STEPS - I:®I )11ib INTO WOOD & STEEL Insert the appropriate nut driver into a 3/8'or 1/2' portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4°, 3/8', 1/2' or metric all thread rod, bolt stock. (The 1/2° requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. I. Insert the appropriate nut driver into a 318'or 1/2" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or bolt stock. Note: When installing SIA,DR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS !JiiJib INTO CONCRETE: Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2' with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8', 1/2', or metric all thread rod or bolt stock. (414SWred nut driver used with 1/2'screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - INTO CONCRETE: Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2' with a hammed rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8"or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. nj nm~ _______ - ._____ i R SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes Into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. -- .- - -- SAMMYS FOR WOOD J Not less than 2' nominal width Wood Flooring • No pre-drilling required. Im 4 Quick to install using the Sammy Not less than I Nut Driver with an 18V cordless 3'nomThal Fi1 drill/driver. thickness (2-117) I . . - (depth or side I Wood Joist L of vertical member) t -" . • Saves time from traditional .7 : : —:: methods. / Double 5heefrock Ceiling • Reduces installation costs. Made in the U.S.A. I —I- _________ , ..• •• ..........,.:. -Warch a video demonsiratbn at www.ftwbuildex.com 1/4" 8002957 GST 100 1/4x1' 210 (7/1603B) 25 125 8003957 GST 200 1/4'x 60 25125; 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8007957 GST 10 1/4 xi' 300 25 125 670 -< 3/8" 8008957 GST 20 1/4x2 1760 (Fir) 850 1475 25 125 i/8.8068925 GST20-6S 1/4 x 2 1760 (Fir) 850 - 25 125 3/8" 8009925 GST 25-380 318x2-112 2113 (Fir) 1500 25 125 #14 Black 3/8 8010957 GST 30 1/4x3 2060 (Fir) 1500 1475 25 125 Nut Driver 3/8' 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 Part #8113910 3/8 8011925 GST 40 114x4 2180 (Fir) 25 125 - 1/2' 8013925 GST2 1/4x2" 1760 (Fir) 25 125 J - - -- 1/2' 8014925 GST 2.5-380 3/8x2-1/2 2113 (Fir) 25 125 - 1/2" 8015925 GST3 1/4x3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 O WNI"U'u; 17 W-S2 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for mainlines. Exception: This requirement shall not apply to 2" or thicket nailing strips resting on top of steel beams. Not less than 2" nominal width (1-1/2') up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4" & 5' pipe 4 ZAffaffg No pre-drilling required. , "Quick to install using the Sammy Flour Joist Nut Driver with an 18V cordless drill/driver. "Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. Watch a 4dao de,nonstrationat = w.vw.itwbulldercom I :111Th? 1 114' 8019957 SWG 200 114x2' 1725 (Fir) 25 125 r 1.313 8020957 SWG 10 114x1 622 (Fir) 300 25 125 I 3/8" 8021957 SWG 20 114x2" 1725 (Fir) 1050 25 125 r -- 3/8 8073925 - SWG 20-SS 1/4x2 1725 (Fir) 850 25 125 3/8" 8022925 SWG 25-380 3/8x 2-1/2" 2249 (Fir) 1500 25 125 - #14SWRed ... ., 8023925 SWG 30 l/4x3" 1884 (Ffr) . 25 11.25 - Nut Driver Part #8114910 May require pm-drilling: consult joist manufacturer. Eliminates distortion of threaded rod. -' "Accommodates up to 3W x 12 pitch roof. -i.-_- ....). 'Allows 17' deflection from vertical. Saves time from traditional methods. Reduces installation costs. 'Made in the U.S.A. Approvals Rod Part Model Size Number #14 Black 3/8" 8139957 SH-GST2O Nut Driver Part#8113910t! 3/8 8141957 SHGST30 j 3/8" JLL. 1/2" 8303957 SH-GST/CST 2.0 5/I6x 1.314" 1406 @ 45°off vertical . - Dim. Lumber May require pro-drilling; consult joist manufacturer. #14 SH Orange Nut Driver Part #8273910 25 125 25 125 25 125 1903 Dim. Lumber 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 45"off vertical .Z"'._. 25 125 Dim. Lumber 903 Dim. Lumber APPROVALS 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2' 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2' 8008957 GST2O 3/8" Vertical 2-1/2' 850 1-1/2' 4" 1475 1-1/2' 8068925 GST2O-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST3O 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2' 8009925 GST2S-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8" Horizontal 3-1/2" - 4"" 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3'** 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 450 Angle off Vertical 2-1/2' 850 1-1/2" 8269957 SH-GST/CST2O 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 3' 1050 1-1/2' 4" 1475 1-1/2' I 8038957 DSTR 1 3/8" Vertical 4" 1500 .035' 4" 1475 .105' 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037' 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK5O 3/8" Vertical 4" 1500 .250" 4' 1475 .188' 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037' 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 3/8' 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK 50 3/8" Vertical 2-1/2' 850 700 Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027' 4" 1475 105' 8153922 XP 35 3/8" Vertical 4" 1500 .060' 4" 1475 125" 8294922 SXP 20 3/8' Vertical or up to 45" 2' 750 .027" 2" 635 .029' 8295922 SXP 35 3/8" Vertical orupto89° 3-1/2" 1250 .060' 2" 635 .029" 8293957 SWXP3S 3/8" Horizontal 3-1/2" 1250 .060" I SAMMYS FOR CONCRETE -PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC2O 3/8' Horizontal 4" 1475 3000 8150922 XP 20 3/8' Vertical 2-1/2" 850 Pre-Pour Structural @3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Ranne U LWC 35 PCF (lbs/ftl 8150922 XP 20 3/8' Vertical 185 .027" 250 .035" 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4' Vertical 185 .027' 250 .035" 8294922 SXP 20 3/8" Vertical 170 .027' 450 80 .027" 8295922 SXP 35 3/8" Vertical 250 .060' 90" 80 .060" 8293957 SWXP 35 3/6" Horizontal 80 .060" 8150922 XP 20 3/8" Vertical 283 .027" Max trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027' Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4 or 3/8 Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies w! NEC Standards Gauge No. 229a. 20 go. 18 go. 16 go. 14 go. l2go. 11/811 3/16" 114" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125' .188" .250' SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-112" UL compliance with NEC Standards. SWG 25-380 Maximum pipe size in wood Umber or joist allowed by UL is 4 UL and FM tests were performed In compliance with NFPA 13 Standards. "SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-112' Fastening requirementS times weight of water-filled schedule 40 pipe plus 250 pounds. **SWG 20 Maximum sine size in wood Umber or joint allowed by UL in 3 SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. Sammye Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root'1mm.i GST 20 .182" 1/8" GST 25-380 .280" 7/32" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com M.$oLrnIDA5co,,TMcA8uI4ARDwE ALSO LaI10531JucNSO FWLWSOAM! -SI Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, dxl, and .igs. Made In the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Fig. 25 - Surge Restrainer C® US LISTED Size Range — One size fits 3/4" thru 2" pipe Material — Pre-Galvanized Steel Function — Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish — Pre-Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 COOPER B-Line Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish — Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved c Vt us USTED Seismic estralnts System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish — Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY• 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599' FAX: 951.737.0330 CUSTOMER SERVICE • 800.785.5266 www.tolco.com Fig. 20021/2 to 200-8 Fig. 200 IA 0iYAI 200_1/2 1/2° (15) /8'-16 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200-/4 3/4" (20) /8"-16 31 /8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) I8"-16 3I8" (85.7) 2/8" (66.7) 12 (5.5) 200-1/4 1/4" (32) /8"-16 33/4" (94.0) 2I8" (73.0) 13 (5.9) 200_1112 11/2" (40) /8"-16 3/8" (98.4) 2I8" (73.0) 14 (6.4) 200-2 (50) /8"-16 41/2" (114.3) (76.3) 15 (6.9) 200-2I2 21/2" (65) /8'-16 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3' (75) /8"-16 5/8" (149.1) 4" (101.6) 29 (13.3) 200_3112 31/2" (90) I8"-16 7I8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7I8" (187.3) 5" (127.0) 35 (16.0) 200-5 (125) 1/2"_13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 (150) 1/2"_13 101/8" 1 (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" 1(200) 1/2"..13 131/8" J (333.4) 1 8I4" (222.2) 136 (62.3) CIL Fig. 200S Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) VOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B3170NFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. 133170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut c@ us USTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in , hanger before before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4 (20mm) thru 8 (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°c) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts - in place of a knurl nut. Order By: Figure number and pipe size .q Designed to meet or exceed requirements of FM DS 2-0. 'a - Fig. 200C Fig. 200F All dimensions In charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200-2I2 to 200-8 Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe /44 types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in / hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) Fig 200-1 to 200-2 in the USA (UL) and Canada (cLJL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) \ \ Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. 2001Y18-1/2 W' (15) M8 31/8 (79.4) 2/8" (66.7) 11 (5.0) 200M10-1/2 1/2' (15) MiO 31/8" (79.4) 2/8 (66.7) ii (5.0) 200M8-3/4 3/4° (20) M8 31/8' (79.4) 21/2' (63.5) 11 (5.0) 200M10-3/4 3/4' (20) M10 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200M8-1 1° (25) M8 3/8' (85.7) 2/8' (66.7) 12 (5.5) 200M1-1 1' (25) M10 3/8° (85.7) 2/8" (66.7) 12 (5.5) 200M8-1114 11/4' (32) MB 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4" (94.0) 2I8" (73.0) 13 (5.9) 200M8-11/2 11/2' (40) M8 3I8' (98.4) 2I8" (73.0) 14 (6.4) 200M10-11/2 11/2' (40) M10 3/8' (98.4) 2/8' (73.0) 14 (6.4) 2001V18-2 2° (50) MB 41/2" (114.3) 3" (76.3) 15 (6.9) 200M10-2 2" (50) M10 41/2 (114.3) 3" (76.3) 15 (6.9) 200M-21/2 21/2' (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3° (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7/8" (187.3) 51/4' (133.3) 34 (15.6) 200M-4 4' (100) M10 7/8 (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 6° (150) M12 10'/a" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8° (200) M12 131/8' (333.4) 8/4" (222.2) 136 (62.3) All dimensionsdimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line 1 ip .,40 - ;-. - e - ZN: Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel — Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"-16 or 1/2"13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. C @ us 11 LISTED 11111 11111 Loci, GUIa t~b (J lB Lii1AII 200H-2-3/8 2° (50) /8"-16 4/16" (115.9) 3/32" (81.7) 48 (21.8) 200H-2-1/2 2° (50) 1/2"_13 423/32" (119.8) 3/8" (85.7) 45 (20.4) 200H-21/2-3/8 21/2" (65) /8"-16 5/16" (134.9) 323/32' (94.4) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"_13 515/32" (138.9) 3/8" (98.3) 56 (25.4) 200H-3-3/8 3° (75) /8"-16 53/4" (146.0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3° (75) 1/2"13 5 /8" (148.1) 331/32" (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8"-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 1 4" 1 (100) 1/2"..13 71/32" (178.6) 419/32" (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line LêFiiJG1'ëThJi!iwa]tt 0 F PP I® Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 150° Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ System Compatible Program* Certified to NSF/ANS/Std 61-G RNK. SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE 0 CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 .jg FAX + 1 800 344-3775 wu 2012 Fire Protection Products, Inc. FPPI5, LubeFit® are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ, Blaze-Maste,, FlowGuard Gold5 and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. 31 cw 1Iftwj L F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. Fog-,. SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 02. 32 02. BIG 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com wu © 2012 Fire Protection Products, Inc. FPPI®, LubeFit5 are registered trademarks of Fire Protection Products, Inc. FBC", BlazeMaster', FlowGuard Gold® and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. WhOw-aw-dfGLIER1T[d1JthnTgLOI TKMTON1__ F PP I® Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. -U © 2013 Fire Protection Products, Inc. FPPI5, ThreadRO are registered trademarks of Fire Protection Products, Inc. LA MADE IN U.S.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke rt SYSTEM COMPATIBLE *FBC" System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1760 599-1168 +1800344-1822 FAX +1800344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300.