HomeMy WebLinkAbout6860 AVENIDA ENCINAS; ; AS160214; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160214 6860 AVEN IDA Job Address: ENCINAS Permit Type: SPRINK Parcel No: 2144501900 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 7/19/2016 Approved: 8/5/2016 Issued: 8/5/2016 Inspector: Project Title: NURSE CLINIC REMODEL T.I.: ADD/RELOCATE NEW FIRE SPRINKLERS FOR TI IN EXISTING SPRINKLERED BLDG. THE EXISTING FIRE SPRINKLER COVERAGE OUTSIDE THE AREA OF WORK WILL REMAIN AND WILL NOT BE AFFECTED BY THE SCOPE OF WORK. Applicant: SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 Owner: KAISER FOUNDATION HEALTH PLAN INC 393 E WALNUT ST PASADENA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 303 0 303 0 Bulletin 111 Rev. P CJ C ct Reflab Model C Recesse d Automatic Sprinkler The Most Compact Attractive and Easily Installed Sprinkler Ever Designed! Features 11/;_," (38mm) Total adjustment provided by adjustable inlet versions. 1/2" (13mm) Total adjustment provided by economical standard inlet version. Adjustable inlet version available with either 1" NPT male or female threads eliminating costly reducing coupling. Small diameter escutcheon. Available in brass, chrome or white finish. Multiple orifice sizes for design flexibility. Listed by Underwriters Laboratories Inc. & Underwriters' Laboratories of Canada. Ap- proved by Factory Mutual Research Corp. & Loss Prevention Council, NYC BS&A No., 587-75-SA. Product Description Today's modern buildings demand that a sprinkler not only provide the best fire protection but also achieve an attractive appearance. Reliable's Model G Recessed Sprinkler meets both criteria. It combines the fire fighting capability of a proven sprinkler with the smallest practi- cable recessing unit. Its small profile does not disrupt the overhead aesthetics, and yet one vertical glance upward gives a visual assurance of the finest in fire protection, an automatic sprinkler system. The Model G Recessed Sprinkler's threaded two-piece construction makes initial field installation a very easy task. It allows ceilings panels to be removed without shutting down the fire protection thus facilitating main- tenance of above ceiling services. The adjustable one inch NPT inlet versions have one and one half inches of adjustment which eliminates both the normally required reducing coupling and the need to accurately cut drop nipples. This sprinkler can be adjusted after the ceil- ing is in place and even while the system is pressurized eliminating the final corrections to pipe hangers or ceil- ings that might otherwise be required. The Reliable Model G Automatic Sprinkler is the heart of the Recessed Sprinkler. This sprinkler utilizes the cen- ter strut solder in compression principle of construction. The fusible alloy, captured in the cylinder of a small sol- der capsule by a stainless steel ball, acts as the trigger of the sprinkler. When the fusible alloy melts, the sprinkler operating parts spring free from the sprinkler clearing the waterway and allowing the deflector to distribute the dis- charging water. ASi 60214 6860 AVENIDA ENCINAS Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Product Description and Installation The Reliable Model G Recessed Sprinkler has been de- signed with ease of installation in mind. A choice of three inlets with up to one inch adjustment coupled with the ½" (13mm) escutcheon adjustment enables most systems to be installed using pro-cut drop nipples. The adjust- ment can be accomplished after the ceiling installation and while the system is pressurized thereby providing sprinkler protection before construction is completed. The Non-Adjustable inlet version (Figure 1) Consists of the Reliable Model G Sprinkler with an attached cup recessed in the ceiling. A ceiling hole of 2 14" (57mm) diameter is recommended. The Adjustable inlet version uses the same sprinkler as the Non-Adjustable inlet version except the 1" of addi- tional adjustment is provided by a telescoping sprinkler inlet section that threads in or out of a stationary Coupling Reducer (either 1 male or 1 'female) as shown in figures 2 or 3. The Sprinkler-Cup assembly comes attached to the inlet Coupling Reducer and is retained from separa- tion past its maximum adjustment length by a snap ring. This combination is simply installed after the system drop nipple, elbow or tee has been 'roughed in" to the dimen- sions shown in figures 2 or 3. Wrenching means are pro- vided by hex flats on the coupling reducer as depicted in the figures-do not wrench on any other part of the sprin- kler. After the ceiling tiles have been cut and installed in place (a 2 1/4" {57mm}hole is recommended), the sprin- kler can be adjusted using the RC-1 Concealed Wrench. When using the wrench in this application, however, do not over-torque beyond the adjustment stops. Figure 4 shows a ½" NFl non-adjustable inlet sprin- kler, with the attached sprinkler cup combination inserted into the special Reliable Model RC-1 Installation Wrench. This wrench must he used. The wrenching pads of the sprinkler easily slip into the rectangular cut-outs of the wrench as the outside diameter locates the threaded cup. A ½" (13mm) drive ratchet can then be used for installation and tightening. Figure 5 shows the removal of the wrench. Care should be taken during this procedure to avoid hitting the de- flector with the wrench. The wrench should be lowered until it clears the sprinkler. The installation completed by threading the escutcheon on until it contacts the coil- ing. To avoid leaving smudge marks on the ceiling, the Reliable Model FEA Flush Sprinkler Escutcheon Wrench should be used. Note: Use hex wrench on Coupling Reducer to tighten Adjustable Sprinkler into fittings. Do not use RC-1 Wrench for this purpose. Do not install the Model G Recessed Sprinkler in ceilings which have positive pressure in the space above. Maintenance The Model G Recessed Pendent Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFFA 20. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler that has been painted (other that factory applied) or damaged in any way. A stock of spare sprin- klers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non-operation. ½' NPT Non—Adjustable Inlet Figure 1 11,IFL_ lJ.) "-ax- N -- j - --------I ' 8 1" NPT Male—Adjustable Inlet Figure 2 V f ,I xx '1 '' 1" NPT Female—Adjustable Inlet Figure 3 11 Technical Data Sprinkler Inlet Total Adjustment Nominal Orifice "K" Factor Thread Sprinkler Approval Identification Organizations U.S. Metric Number (SIN) Non-Adjustable ½" (13mm) ½' (15mm 562 81.0 ½' NPT (R½) 1, 2. 3 4. 5. 7 R1015 Non-Adjustable ½" (13mm) Ar," (11mm) 4.24 61.0 ½" NPT (R½) 1,3,4 R1013 Non-Adjustable ½" (13mm) /" (10mm) 2,82 40.6 ½" NPT (R½) 1. 3, 4 131011 Non-Adjustable ½" (13mm) 17/12" (20mm) 7.96 114.7 ½" NFl (R½) 1.3 R1016 Adjustable 1½" (.38mm) ½"(5mm) 5.53 79.7 1" NPT Male or Female 1,2,3.4 191118 Adjustable 11/2' (38mm) 7A1" (1 1. mm) 4.24 61.0 1" NPT Male or Female 1, 3, 4 All 13 Adjustable 111/2" (38mm) 2/1"(10mm) 2.75 39.2 1" NPT Male or Female 1.3,4 R1117 Adjustable 1½" (38mm) 15mm 5.53 79.7 RI Male or Female 5 R1118 Note: Sprinkler escutcheon provides ½" (131nm) of the total adjustment. Adjustable inlets, when used, provide 1" (2511-11TI) of the total adjustment. Temperature Ratings Sprinkler Rating Maximum Ambient Classification Temperature OF I °COF oc Ordinary 135 57 100 38 Ordinary 165 74 100 I 38 Intermediate 212 100 150 66 Approval Organizations Underwriters Laboratories Inc. Factory Mutual Research Corp. Light Hazard Occupancies - No limitations Ordinary Hazard Occupancies - Groups 1 & 2, Wet Systems Only Underwriters Laboratories of Canada NYC BS & A No. 587-75-SA Loss Prevention Council XLH, CHI and OHll Occupancies Only NYC MEA 258-93-F EC Certificate: 1438-CPD-0054 (R1015) Note: Unless otherwise indicated, Ordinary hazard ap- provals are without limitations. 7/;/' (1 1mm) and /" (10mm) orifice sprinklers are limited to light hazard occupancies. Ordering Information Specify: Temperature Rating Nominal Orifice Sprinkler Finish Escutcheon Finish Sprinkler Type: Either Non-Adjustable Inlet (Fig. 1) 1" male Adjustable Inlet (Fig. 2)1" Female Adjustable Inlet (Fig. 3) Finishes (1) Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome White Painted White Fainted Special Application Sprinkler Escutcheon Bright Brass 2' Bright Brass Black Plated Black Plated Satin Satin Polyester Coated Polyester Coaled (1) Other color Finishes available upon request. Consult Factory for details. ' Only frame, deflector and cap are plated Only frame and deflector are painted or coated. Operating parts are chrome plated. UL Listed and MEA Approved only. igure 4 Figure 5 F 3, F] Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed arid serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co, Inc. Recycled ReliabILA (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03115 P/N 9999970006