Loading...
HomeMy WebLinkAbout7720 EL CAMINO REAL; ; FPC2021-0058; PermitPERMIT REPORT (_City of Carlsbad Print Date: 01/28/2022 Job Address: 7720 EL CAMINO REAL, CARLSBAD, CA 92009-8509 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2161241600 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2021-0058 Status: Closed - Finaled Applied: 04/22/2021 Issued Finaled Close Out: 01/28/2022 Inspector: Final Inspection: Project Title: Description: BEACON PHASE II -PROVIDE WET PIPE AUTOMATIC SPRINKLER SYSTEM FOR EXISTING BLDG A (384 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, U STE 14 . VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 System > 100 heads (includes 1 riser) $858.00 Total Fees: $858.00 Total Payments To Date: $858.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov (ITAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPRESSION HYDRAULIC CALCULATIONS BEACON BLDG. A 7720 EL CAMINO REAL CARLSBAD, CA. 92009 CONTRACT NO. 21176 1341 Distribution Way, Suite 14 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page QLIIALN Municipal Water District Fire Flow Test Results Asset lD# WFHD3117 I I EAM# 340713 Flow Test Requested By:: Mayra Marron Telephone: 951-302-21 63 Email: mmarron@titanfpinc.com Project Name:7720 El Camino Real DMWD Personnel Conducting: Mike Salazar, Bryan Rickards Date: 3/8/2021 rime: 11:20am ddress:772° El Camino Real ity:rl bounty: San Diego Pressure Zone: Hydrant (flow) Elevation: 58feet Pipe Diameter: 8 inches Hydrant (gauge) Elevation: 63feet Pipe Diameter: 8 inches Reservoirs Involved: P.R. Stations Involved:: rsf north & south, village park, la costa, vales 1, gardendale, southeast 2, wanket, quails Distribution System: Dead End Looped Static Pressure (prior to flow test): 167 P.S.I. Residual Pressure (during flow test): 145 P.S.I. PITOT Residual Pressure, 2 1/2 inch port: 110 P.S.I. Calculated Flow: 1696 G.P.M. Comments: Test Results Reviewed By: MS Job Name FOR HYDRAULIC CALCULATIONS Job Location - REFERENCE ONLY. INSTALLATION BY Engineer _____ OTHERS. .O. No. Approval Representative MasterSeries® LF876V Prevention Assemblies (Type The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e. pollutant) application in accordance with Local Governing Water Utility Code. The coating on this backfiow assembly uses ArmorTekrM technol- ogy to resist corrosion due to microbial induced corrosion (MIC) or exposed metal substrate. This Backfiow Assembly is primarily used on potable drinking water systems and fire sprinkler sys- tems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal "N-Pattern" Installations Vertical-Up "Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Utilizes advanced ArmorTekTM coating technology to resist cor- rosion of internals Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1st & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4" Check Assembly No Special Tools Required for Servicing Field Replaceable Seat & Disc Detect Potential Underground Water Leaks Detect Unauthorized Water Usage Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL! FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by AWVA Standard C510. The auxiliary bypass line contains a 5/8"x1/4" Water Meter that complies with ANSI/AWWA Standard C700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The valve body shall utilize a coating system with built-in electrochemi- cal corrosion inhibitor and microbial inhibitor. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of AWVVA Standard C510 flow and pressure loss performance parameters. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Inquire with governing authorities for local installation requirements *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact FEBCO Technical Service. FEBCO reserves the tight to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold. A WAITS Brand Options - Suffix OSY: UL!FM Approved OS&Y Gate Valves [ANSI/AWWA C515 Compliant] DNRS: Domestic Non-Rising Stem Gate Valves [ANSI/AWWA C509 Compliant] CFM: Totalizing Cubic feet/min 5/8"x 3/4" Water Meter [ANSI! AWWA C700 Compliant] GPM: Totalizing Gallons/mm %"x 3/4" Water Meter [ANSI! AWWA C700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4" LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4" LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer: FDA Approved [ASME B16.1 Class 125 & AWWA Class D Flange] Series 611 Valve Setter MJ x MJ - Mechanical Joint x Mechanical Joint [AWWA C111!A21.11] MJ x FL - Mechanical Joint x Flange [AWWA Cl 11!A21.11; ASME B16.1 Class 125/AWWA Class D Flange] FL x FL - Flange x Flange [ASME B16.1 Class 125 & AWWA Class D Flange] Materials Below is a general materials list of the Model LF876V All assemblies size 21/2" through 10" is similar in materials and construction. Please contact your local FEBCO Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [FCCCHR-USC] ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved IAPMO/cUPC AWWA Standard C510 Compliant End Connections: Compliant to ASME 1316.1 Class 125 & AWWA Class D Flange Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL!FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21/2." - 10") - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC Vertical Up (Z-Pattern 21/2" - 10") - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC < aFM Approved C us C 0—S CH Q 9 1048 B64.5 Pressure - Temperature Max. Working Pressure: 175psi (12.1 bar) Mm. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350psi (24.1 bar) Hydrostatic Safety Pressure: 700p5i (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous Fusion epoxy coated internal and external AVWVA C550-90 OSY resilient wedge gate valve AW (IJL/FM) Stainless Steel Stainless Steel Silicone Stainless Steel AWWA C606 LM Shut Coating: Shutoff Valves: Check Seats: Disc Holder: Elastomer Disc: Spring: Clamp: off 55 Dimensions - Weights Size: 21/2" - loll Below are the nominal dimensions and physical weights for the Model LF876V size 21/2' through 10". Allowances must be made for normal manufacturing tolerances. Please visit our webse to download a copy of this product's installation instructions, or contact your local FEB00 Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) Note: The Series LF876V is shipped in the standard (N-Pattern) oentation as shown above. Gate Valve Side View Clearance LF876V SIZE DIMENSIONS WEIGHT - i in. in. mm B in. mm C in. mm D in. mm E in. mm F in. mm G in, mm H in. mm I in. mm J in. mm in. K* mm L in. mm I OSY lbs. kg. 21/2 291/8 740 121/2 318 61/4 159 251/4 642 171/2 445 13/s 346 271/4 692 51/2 140 111/8 283 31/2 89 16% 416 111/2 292 216 98 3 291/8 740 121/2 318 61/4 159 253/4 654 173/4 451 14'/s 359 281/4 718 51/2 140 111/8 283 33/4 95 187/8 479 111/2 292 242 110 4 311/8 791 14 356 7 178 273/4 705 183/4 476 151/2 394 31 787 6 152 111/8 283 41/2 114 223/4 578 13 330 347 157 6 353/4 908 16 406 8 203 323/4 831 221/8 562 18/i 473 371/4 946 71/4 184 121h 316 5½ 140 301A 765 13 330 529 240 8 40% 1035 181/2 470 9¼ 235 36% 933 251/8 638 20/4 527 41112 1054 81/2 216 14 356 6/4 172 3734 959 141/, 368 827 375 10 461/4 1175 21 533 1O/16 264 413A6 1047 281/4 714 2311A6 601 73/81202 95/8 244 151A6 398 8 203 453/4 1162 131/8 333 1335 606 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) ** Indicates weight of complete Backf low Assemblies with specified Gate Valves Performance Flow capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. AWWA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than 1 Ofps. UL flow rate is determined by typically rated Velocity of 15 feet/sec. Pipe Support (furnished by customer) for valve weight Only. Vertical Orientation "Z-Pattern- Flow Curve Z Standard Orientation"N-Pattern" Row Curve N Capacity N-Pattern Z- Pattern 21/0 LF876V psi Service Flow Rated Flow *UL Rated Flow 22 I 20 I I 18 I I I 16 I CL 14 I I 2 12 I I I 10 I 8 -4---- L.. I I 6 4 (___•__________________- -I I 2 I I 0 I I 025 SO 751001251501752002252502153003253509pin 284 568 852 1136 1pm 7.5 14.7 22.0 fps LF876V psi Service Flow Rated flow *UL Rated Flow 22 20 I I 18 I I I 16 I I I CL 14 I I 1!-H - o 0 50 100 150 200 250 300 350 400 450 500 glom 379 757 1136 1514 1pm 7.5 14.5 22.0 fps psi LF876V Service Row Rated Flow *UL Rated Flow 18 16 I I 14 I I 12 1O - 2 I I I 0 I I I I I 0 100 379 200 300 400 1136 7.5 500 600 1893 12.8 700 800gpm 2650 1pm 19.1 fps 6" LF876V psi Service Flow Rated Row 111 Rated Flow 18 16 I I 14 cL 12 I I I I 10 I I :--- 4 r 0 200 400 600 800 1000 1200 1400 1600gpm 757 2271 3785 5300 1pm 7.5 11.4 17.0 fps 8" LF876V psi Service Row Rated Row *UL Rated flow 18 16 14 12 a 10 5 8 L. 4 0 400 800 1200 1600 2000 2400 gpm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps loll LF876V PSI Service Flow Rated Flow *U1 Rated Flow 10 t 7 6 8 5 4 5- 3 2 0 0 500 1000 1500 2000 2500 3000 3500 gpm 1892 3785 5678 7570 9463 11356 132481pm 7.5 9.4 14.1 fps A WAITS Brand ES-F- LF876V 2015 USA: T: (800) 767-1234 • F: (800) 788-4491 • FEBC0onhine.com Canada: T: (888) 208-8927 • F: (888) 479-2887 • FEBCOonhine.ca Latin America: T: (52) 55-4122-0138 • FEBCOonline.com 02019 FEBCO Hydraulic Calculations for Project Name: Drawing 1 Location: Drawing Name: 21176 - Beacon Phase ll_FP design A-7720 Calculation Date: 4/16/2021 Design Remote Area Number: Remote Area Location: L2 Occupancy Classification Ordinary Group II Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm/ft2 I 500ft2 (Actual 1555ft2) 130ft2 Upright 19 0 N/A gpm at Node: N/A 250.00 at Node: I Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 825.32 @ 128.068 Type of System: Volume of Dry/PreAction/Antifreeze/OtherA N/A Allowance at Source (Safety Margin = 16.428) Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: 108.669 M.E.P.CAD, Inc. AutoSPRlNK 2020 BETA v16.3.1.0 1 4/16/202111:17:03AM Page 1 120 (I) 0 Job Name: Drawingi Remote Area Number: 1 200- 160 140 100 180 80 60 20 - liJ.I.I.lJ.j.I.IIIIIII I0350 700 1050 Supply 4Summary sheet Node: 1 Static r32©16 Pressure 150.300 575.32 825.32 g 128.068 with Hose Allowance at Sou 166.00 128.300 System demand curve lilIllIll IIIIIII 111111 I It 111111 III I I I I I I I I I I I I I I I I I I I I 1400 2100 1750 2450 Flow - gpm Hydraulic Graph N 1.85 2800 3150 Date: 4/16/2021 3500 ,© M.E.P.CAD, Inc. EI AutoSPRINK 2020 BETA 06.3.1.0 4/16/2021 11:17:04AM Paqe 2 IN Summary Of Outfiowing Devices I Job Number: 1 Reocrt Descriotion: Ordinry Groun 11 (1) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 1021 28.92 26.00 5.6 26.662 c Sprinkler 1022 26.00 26.00 5.6 21.556 Sprinkler 1023 29.26 26.00 5.6 27.296 Sprinkler 1051 29.08 26.00 5.6 26.972 Sprinkler 1052 26.16 26.00 5.6 21.828 Sprinkler 1053 29.43 26.00 5.6 27.611 Sprinkler 1097 27.61 26.00 5.6 24.309 Sprinkler 1121 29.77 26.00 5.6 28.251 Sprinkler 1122 28.19 26.00 5.6 25.341 1 Sprinkler 1123 30.11 26.00 5.6 28.916 1 Sprinkler 1124 33.54 26.00 5.6 35.870 Sprinkler 1170 31.89 26.00 5.6 32.423 Sprinkler 1171 32.21 26.00 5.6 33.079 Sprinkler 1172 32.84 26.00 5.6 34.389 Sprinkler 1180 31.79 26.00 5.6 32.220 Sprinkler 1219 31.84 26.00 5.6 32.329 Sprinkler 1220 32.16 26.00 5.6 32.980 Sprinkler 1221 32.79 26.00 5.6 34.281 Sprinkler 1229 31.74 26.00 5.6 32.130 c Most Demanding Sprinkler Data © M.E.P.CAD, Inc. MAutoSPRINK 2020 BETA 06.3.1.0 4/16/2021 11:17:05AM Page 4 Job Name: Drawingi Remote Area Number: I Date: 4/16/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 150.300 128.300 1 1696.00 144.496 825.32 128.068 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -2-11 Supply 128.068 575.32 1021 25-3% Sprinkler 26.662 28.92 1022 25-3% Sprinkler 21.556 26.00 1023 25-3% Sprinkler 27.296 29.26 1051 25-0% Sprinkler 26.972 29.08 1052 25'-O% Sprinkler 21.828 26.16 1053 25-0% Sprinkler 27.611 29.43 1097 24101/2 Sprinkler 24.309 27.61 1121 24'-81/2 Sprinkler 28.251 29.77 1122 24-81/2 Sprinkler 25.341 28.19 1123 24-81/2 Sprinkler 28.916 30.11 1124 24-8% Sprinkler 35.870 33.54 1170 24'-4 Sprinkler 32.423 31.89 1171 24-4 Sprinkler 33.079 32.21 1172 24-4 Sprinkler 34.389 32.84 1180 24-4 Sprinkler 32.220 31.79 1219 23-111/2 Sprinkler 32.329 31.84 1220 23-111/2 Sprinkler 32.980 32.16 1221 23'-111/2 Sprinkler 34.281 32.79 ,©M.E.P.CAD, Inc. lflAutoSPRINK 2020 BETA' 4/16/2021 11:17:07AM Pages Job Name: Drawingi Remote Area Number: 1 Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1229 23ll1/2 Sprinkler 32.130 31.74 2 -2-11 127.156 4 -2-11 122.986 5 -2-11 123.142 6 -2-11 126.443 7 -2-11 126.631 9 -7-11 127.360 10 -2-11 127.429 11 -2-11 127.225 15 -2-11 127.474 17 -2-11 127.516 21 -2-11 127.215 29 -2-11 127.568 68 10-0 113.409 101 249h/2 28.295 102 2491/2 22.936 103 24'-9Y2 28.960 139 24'-6Y2 28.625 140 24'-6Y2 23.226 141 2461,4 29.296 B235 0-6 Gauge 121.106 242 -2-11 122.799 243 2441/2 25.838 ,© M.E.P.CAD, Inc. AlAutoSPRINK 2020 BETA 4/16/2021 11:17:07AM Page 6 Job Name: Drawng1 Remote Area Number: 1 Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 272 2421,4 29.975 274 2421/2 26.921 275 24-21/2 30.673 276 2421/2 37.965 375 22'-101/2 34.209 376 22101/2 35.925 377 22-10/ 39.319 387 24'-O% 36.855 388 2401/2 36.859 389 240h/2 37.054 390 2401/2 37.084 391 240h/2 37.754 392 24-0% 37.824 393 24-0% 39.199 394 24-0% 39.303 516 23-9% 34.355 517 239h/2 35.043 518 23-91/2 36.417 526 23-9% 34.152 571 12-3 99.989 578 23-5 34.262 579 23'-5 34.945 580 23-5 36.308 ,©M.E.P.CAD, Inc. IlAutoSPRINK 2020 BETA' 4/16/2021 11:17:07AM Page 7 Job Name: Drawingi Remote Area Number: I Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 588 23-5 34.057 ,© M.E.P.CAD, Inc. 1]AutoSPRlNK 2020 BETA 4/16/2021 11:17:07AM Page 8 Job Name: Drawingi Remote Area Number: I Date: 4/16/2021 Pipe Information Node 1 Elevi (Foot) K-Factor Flow added this step (q) Nominal ID Fittings& Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as nop+iuo .iI.ia ___________________ Fitting (Foot) _________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 1022 25-3% 5.6 26.00 1 (See Notes) 0'6 120 21.556 ••••• Route I '' Sprinkler, PO(5'-O) 5'Q 0.211435 0.217 102 2491/2 26.00 1.0490 5-6 1.163 102 24-9% 11/2 8'-lO 120 22.936 0.021212 0.103 140 24'-6% 26.00 1.6820 8 -10 0.187 140 24-6% 26.16 11/2 (See Notes) 13-1% 120 23.226 Flow (q) from Route 2 4E(4--1 11/2) 19'-9% 0.076914 0.080 243 244h/2 52.16 1.6820 32'-11 2.533 243 24-4% 27.61 1 6'-O 120 25.838 Flow (q) from Route 3 0.168779 0.070 274 24'-2% 79.77 1.6820 6'-O 1.013 274 24'-21/2 28.19 11/2 (See Notes) 7-10 120 26.921 Flow (q) from Route 4 3E(4-11%) 14'-10 0.295422 0.583 375 22-101/2 107.96 1.6820 22-8% 6.704 375 22-101/2 11/2 (See Notes) 1'2 120 34.209 PO(8'-O) 8-0 0.365572 -0.506 389 24-0% 107.96 1.6100 9-2 3.351 389 24'-O% 151.29 0-6 120 37.054 Flow (q) from Route 5 0.059523 390 24'-O% 259.26 3.2600 0-6 0.030 390 24-0% 63.73 7'-6 120 37.084 Flow (q) from Route 13 0.089387 391 24'-O% 322.99 3.2600 7-6 0.670 391 24'O% 88.80 3 0-6 120 37.754 Flow (q) from Route 7 0.140094 392 24-0% 411.78 3.2600 0'-6 0.070 392 24-0% 64.37 3 7-6 120 37.824 Flow (q) from Route 15 0.183277 0.000 393 24-0% 476.15 3.2600 7-6 1.375 393 24-0% 33.54 0-6 120 39.199 Flow (q) from Route 19 0.207873 394 24'-O% 509.69 3.2600 0-6 0.104 , © M.E.P.CAD, Inc. MAutoSPRINK 2020 BETA 06.3.1.0 1 4/16/2021 11:17:09AM Page 9 Job Name: Drawinql Remote Area Number: I Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as npgtiup Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ______________ Friction(Pf) 394 24-01/2 65.63 3 (See Notes) 131'81h 120 39.303 Flow (q) from Route 17 E(9-5), C(20'-2), T(20-2), EE (4-01/2) 82'-0 0.260082 5.105 571 12-3 575.32 3.2600 2138h/z 55.581 571 12-3 4 (See Notes) 99'81/2 120 99.989 2EE(5'-3), T(26'-4), 3E(13-2) 76-41/2 0.070673 0.975 68 101-0 575.32 4.2600 176-1 12.444 68 10-0 4 (See Notes) 8101/2 120 113.409 ALV(28'-O), BV(16'-81/2), BOR 448h/2 0.066769 4.119 B235 0'-6 575.32 4.3100 53'-71/2 3.579 B235 0'-6 6 (See Notes) 35 120 121.106 E(17'-7) 17'-7 0.010061 1.481 242 -2-11 575.32 6.3570 -2-11 0.211 242 6 (See MV 150 122.799 E(11-5%) Notes) -51/2 0.015435 -0.005 4 -2-11 575.32 5.3490 125h/2 0.192 4 -2-11 6 (See Notes) 53 140 122.986 LtE(14'-2) 14-2 0.008027 5 -2-11 575.32 6.2800 19-5% 0.156 5 -2-11 6 (See Notes) 96 120 123.142 2GV(0-0), 2T(0-0), BFP(-3.50 7), E(17'-7) 17'-7 0.010061 -0.000 6 -2'- 11 575.32 6.3570 27'-1 3.301 6 -2-11 6 (See Notes) 1'3 140 126.443 E(22'-l) 22-1 0.008027 7 -2-11 575.32 6.2800 23'-4 0.187 7 -2-11 6 (See Notes) 1821/2 140 126.631 T(47'-3%) 4731/2 0.008027 2 -2-11 575.32 6.2800 65'-5% 0.526 2 -2'- 11 10 (See Notes) 34331c 150 127.156 1(37-6) 37-6 0.000180 11 -2 -11 185.57 8.6780 380'-91/2 0.069 11 -2'-ll 8 (See Notes) 432'J1/2 150 127.225 1(18-8%) 188l/z 0.000767 1 -0.003 29 -2-11 185.57 6.4470 451'-3% 1 0.346 (,.©M.E.P.CAD, Inc. JAutoSPRINK 2020 BETA v16.3.1.0 1 4/16/2021 11:17:09AM Page 10 Job Name: Drawing I Remote Area Number: 1 Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting!Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as nopfbIa snl..o Fitting (Foot) Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 29 -2'- 11 8 (See Notes) 651'9% T 150 127.568 J I I s t 0.000767 0.000 1 -2-11 185.57 6.4470 651-91/2 0.500 250.00 128.068 Hose Allowance At Source Total(Pt) Route 1 1 825.32 1052 2501/2 5.6 26.16 1 (See Notes) 0'6 120 21.828 •••••Route 2••••' Sprinkler, P0(5-0) 5-0 0.213898 0.220 140 24-6% 26.16 1.0490 5-6 1.178 23.226 Total(Pt) Route 2 1097 2410h/2 5.6 27.61 1 (See Notes) 0-6 120 24.309 '••'Route3'•''' Sprinkler, P0(5-0) 5-0 0.236294 0.225 243 24-4% 27.61 1.0490 5-6 1.304 25.838 Total(Pt) Route 3 1122 2481/2 5.6 28.19 1 (See Notes) 0-6 1 120 25.341 ••••• Route 4• ••" Sprinkler, P0(5-0) 5'0 0.245558 0.225 274 24-21/2 28.19 1.0490 5-6 1.355 26.921 Total(Pt) Route 4 1021 25-3 % 5.6 28.92 1 (See Notes) 0-6 120 26.662 ••"Route5 ''••' Sprinkler, P0(5-0) 5-0 0.257384 0.217 101 24-9% 28.92 1.0490 5'-6 1.416 101 24-9% 11/2 8-10 120 28.295 0.025822 0.103 139 24-6% 28.92 1.6820 8-10 0.228 139 24-61/2 29.08 11/2 12-10 120 28.625 Flow (q) from Route 6 0.093587 0.150 272 24-21/2 58.00 1.6820 12-10 1.200 272 24-21/2 29.77 11/2 (See Notes) 9'O% 120 29.975 Flow (q) from Route 9 3E(4'-111/2),P0(9-11) 24'-9 0.201382 0.078 387 24-0% 87.76 1.6820 33-91/2 6.802 387 240h/2 3 0-6 120 36.855 0.008025 388 240h/2 87.76 3.2600 0-6 0.004 ,©M.E.P.CAD, Inc. M. AutoSPRINK 2020 BETA v16.3.1.0 1 4/16/2021 11:17:09AM Page 11 Job Name: Drawingi Remote Area Number: I Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) _________ Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) ______________ Friction(Pf) 388 24'-0% 63.53 3 810h/2 J 120 36.859 Flow (q) from Route 11 0.021976 389 24-0% 151.29 3.2600 8-10% 0.195 37.054 Total(Pt) Route 5 1051 25'-O% 5.6 29.08 1 (See Notes) 0-6 120 26.972 •••'• Route 6••••• Sprinkler, P0(5-0) 5-0 0.260151 0.220 139 24'-6% 29.08 1.0490 5'-6 1.433 28.625 Total(Pt) Route 6 1023 25-3% 5.6 29.26 1 (See Notes) 0-6 120 27.296 ••••• Route 7 • Sprinkler, P0(5-0) 5-0 0.263038 0.217 103 24-91/2 29.26 1.0490 5-6 1.447 103 24-91/2 11/2 8'-10 120 28.960 0.026389 0.103 141 24-6% 29.26 1.6820 8'-lO 0.233 141 24-61/2 29.43 11/2 12-10 120 29.296 Flow (q) from Route 8 0.095639 0.150 275 24-21/2 58.68 1.6820 12'-lO 1.227 275 24-21/2 30.11 11/2 (See Notes) 7'10 120 30.673 Flow (q) from Route 10 3E(4'-111/2) 14'-10 0.205785 0.583 376 22-10% 88.80 1.6820 22-81/2 4.670 376 22-101/2 11/2 (See Notes) 1'2 120 35.925 PO(8'-O) 8-0 0.254650 -0.506 391 24-0% 88.80 1.6100 9-2 2.334 37.754 Total(Pt) Route 7 1053 25-0 % 5.6 29.43 1 (See Notes) 0'6 T 120 27.611 '•Route8 .". Sprinkler, P0(5-0) 0.265844 0.220 141 24-6% 29.43 1.0490 5-6 1.464 29.296 Total(Pt) Route 8 1121 24-8% 5.6 29.77 1 (See Notes) 0'-6 120 28.251 ••... Route 9• Sprinkler, P0(5-0) 5-0 0.271539 0.225 272 24-2% 29.77 1.0490 5-6 1.499 29.975 Total(Pt) Route 9 © M.E.P.CAD, Inc. MAutoSPRINK2020 BETA 06.3.1.0 1 4/16/2021 11:17:09AM Page 12 Job Name: Drawingi Remote Area Number: I Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as flpJfflIfl WIIIA Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ______________ Friction(Pf) 1123 24-8 % 5.6 30.11 1 (See Notes) 0'-6 120 28.916 '••• Route 10 -999 Sprinkler, P0(5-0) 5-0 0.277443 0.225 275 24-2% 30.11 1.0490 5-6 1.531 30.673 Total(Pt) Route 10 1229 23-111/2 5.6 31.74 1 (See Notes) 0'-6% 120 32.130 Route 11 Sprinkler, PO(5'-O) 5-0 0.305854 0.233 588 23-5 31.74 1.0490 56h/2 1.694 588 23'-5 vi 8-8 120 34.057 0.030684 -0.171 526 239h/2 31.74 1.6820 8'-8 0.266 526 23-9% 31.79 1% (See Notes) 5'61/2 120 34.152 Flow (q) from Route 12 2E(4-111/2), PO(9'-11) 19'-9% 0.110761 -0.099 388 24-0% 63.53 1.6820 25-4 2.807 36.859 Total(Pt) Route 11 1180 24'-4 5.6 31.79 1 (See Notes) 06h/2 1 120 32.220 '•"Route 12" Sprinkler, PO(5'-O) I 0.306650 0.233 526 23'-9% 31.79 1.0490 56l/2 1.698 34.152 Total(Pt) Route 12 1219 23111/2 5.6 31.84 1 (See Notes) 0'-6% 120 32.329 ''''Route 13.'.'. Sprinkler, P0(5-0) 5-0 0.307607 0.231 578 23-5 31.84 1.0490 5'-6% 1.702 578 23'-5 8-8 120 34.262 0.030860 -0.174 516 23-9% 31.84 1.6820 8-8 0.267 516 23-9% 31.89 11/2 (See Notes ) 5'61/2 120 34.355 Flow (q) from Route 14 2E(4-111/2), P0(9-11) 19-9% 0.111401 0.094 390 24-0% 63.73 1.6820 25-4 2.823 37.084 Total(Pt) Route 13 1170 24-4 5.6 31.89 1 (See Notes) 0-61/2 120 32.423 '''' Route 14''''• Sprinkler, P0(5-0) 5-0 0.308433 0.228 516 23-9% 31.89 1.0490 5-61/2 1.705 34.355 Total(Pt) Route 14 © M.E.P.CAD, Inc. Lffl AutoSPRINK 2020 BETA v16.3.1.0 1 4/16/2021 11:17:09AM Page 13 Job Name: Drawing'! Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal io Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as napflfiwo u.Illa Fitting (F oot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 1220 23'-11Y2 5.6 32.16 1 (See Notes) 061/2 120 32.980 •••'•Route 15..''' Sprinkler, P0(5-0) 5-0 0.313333 0.231 579 23-5 32.16 1.0490 5-6% 1.734 579 23-5 11//2 8-8 120 34.945 0.031435 -0.174 517 23'-9% 32.16 1.6820 8'-8 0.272 517 23'-9% 32.21 P/2 (See Notes) 561/2 120 35.043 Flow (q) from Route 16 2E(4-11Y2), P0(9-11) 1991/2 0.113479 0.094 392 24'-01h 64.37 1.6820 25-4 2.875 37.824 Total(Pt) Route 15 1171 24-4 5.6 32.21 1 (See Notes) 0-6% 120 33.079 ••••• Route 16..... Sprinkler, P0(5-0) 5-0 0.314200 0.228 517 23'-9% 32.21 1.0490 5-6% 1.736 35.043 Total(Pt) Route 16 1221 23-11% 5.6 32.79 1 (See Notes) O'-6Y2 120 34.281 ••••• Route 17••••• Sprinkler, PO(5'-O) 5-0 0.324746 0.231 580 23-5 32.79 1.0490 5-6% 1.797 580 23-5 11/2 8'-8 120 36.308 0.032580 -0.174 518 239h/2 32.79 1.6820 0.282 518 23-9% 32.84 11/2 (See Notes) 561/2 120 36.417 Flow (q) from Route 18 2E(4'-11Y2), P0(9-11) 199h/ 0.117621 -0.094 394 24'-0/ 65.63 1.6820 25-4 2.980 39.303 Total(Pt) Route 17 1172 24'-4 5.6 32.84 1 (See Notes) 06h/ 1 120 34.389 •• • Route 18..... Sprinkler, P0(5-0) t 0.325694 0.228 518 23'-9% 32.84 1.0490 5-61/2 1.800 36.417 Total(Pt) Route 18 1124 24'-8% 5.6 33.54 1 Notes) 120 35.870 1 .. ... Route 19''''' Sprinkler, I P0(5-0) 5-0 0.338653 0.225 276 24-21/2 33.54 1.0490 5-6 1.869 , © M.E.P.CAD, Inc. JjJAutoSPRlNK 2020 BETA 06.3.1.0 1 4/16/2021 11:17:09AM Page 14 Job Name: Drawingi Remote Area Number: 1 Date: 4/16/2021 Pipe Information Node 1 Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (F oot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 276 24-2 % 1% (See Notes) 7'lO 120 37.965 3E(4-111/2) 14-10 0.033975 0.583 377 22-10% 33.54 1.6820 228h/2 0.771 377 22-101/2 11/2 (See Notes) 12 120 39.319 P0(8-0) 8-0 0.042043 -0.506 393 24-0% 33.54 1.6100 9-2 0.385 39.199 Total(Pt) Route 19 9 -2-11 389.74 10 97-9% 150 127.360 '• '''Route 20''''' Flow (q) from Route 21 0.000712 10 -2-11 389.74 8.6780 97-91/2 0.070 10 4-11 10 (See Notes) 541 150 127.429 EE(8'-3) 8-3 0.000712 15 4-11 389.74 8.6780 62-4 0.044 15 -2-11 10 (See Notes) 22'9% 150 127.474 T(37-6) 37-6 0.000712 17 -2'- 11 389.74 8.6780 60-3% 0.043 17 -2-11 8 (See Notes) 16361/2 150 127.516 5, T(18-8%) 18-8% 0.003025 1 -2-11 389.74 6.4470 182-3 0.551 128.068 Total(Pt) Route 20 2 -2'-1 1 185.57 10 85-1 150 127.156 •••. Route 21 Flow (q) from Route 1 0.000712 -0.002 21 -2-11 389.74 8.6780 85-1 0.061 21 4-11 10 (See Notes) 1965 150 127.215 EE(8-3) 8-3 0.000712 -0.001 9 -2-11 389.74 8.6780 204'-8 0.146 127.360 Total(Pt) Route 21 ,©M.E.P.CAD, Inc. jU AutoSPRINK 2020 BETA06.3.1.0 1 4/16/2021 11:17:09AM Page 15 Job Name: Drawingi Remote Area Number: 1 Date: 4/16/2021 IEauivaIent Pioe Lenoths of Valves and Fittinas (C=120 onlv)I IC Value Multiplier I Actual Inside Diameter 4.87 - Factor Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter) - Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11140 Elbow Ee2 221/2o Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap &© M.E.P.CAD, Inc. Ifl AutoSPRINK 2020 B ETA v16.3.1.0 1 4/16/2021 11:17:09AM Page 16 Hydraulic Calculations for Project Name: Drawingi Location: Drawing Name: 21176 - Beacon Phase ll_FP design A-7720 Calculation Date: 4/16/2021 Design Remote Area Number: 2 Remote Area Location: L2 Occupancy Classification: Ordinary Group II Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm/ft2 1500ft2 (Actual 1511ft2) 130ft2 Upright 21 0 N/A gpm at Node: N/A 250.00 at Node: I Type Allowance at Source (Safety Margin = 28.013) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 900.59 @ 115.466 Type of System: Volume of Dry/PreAction/Antifreeze/OtherA N/A Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes Automatic peaking results Left: N/A Right: N/A (A M.E.P.CAD, Inc. AutoSPRINK 2020 BETA v16.3.1.0 2 4/16/202111:16:I3AM Page 1 Hydraulic Graph Job Name: Drawingi N 1.85 Remote Area Number: 2 Date: 4/16/2021 200-- Supply I Summary Sheet 180: - I Node: I 160- Static Pressure 150.300 00 59gv143 479 140H 1696.00 128.300 120- - 1156 100- - _____ U) Cl) 900.59 with Hose Allowance at Source a- 80 - fSyst . em demand curve 60- 40---- 20- o- JJjjj_iIIIIIIIl 111111111 ICililill IllilCill 11111111 liii II! I 11111 I I I I I I C I I I C I 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Flow - gpm (&© M.E.P.CAD, Inc. i1 AutoSPRINK 2020 BETA v16.3.1.0 4/16/2021 11:16:14AM Paqe 2 ISummary Of Outfiowing Devices I Job Number: 1 Report Description: Ordinary Group 11 (2) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) i Sprinkler 201 26.00 26.00 5.6 21.556 Sprinkler 202 26.08 26.00 5.6 21.693 Sprinkler 203 26.73 26.00 5.6 22.792 Sprinkler 204 26.82 26.00 5.6 22.936 Sprinkler 205 27.23 26.00 5.6 23.648 Sprinkler 206 27.53 26.00 5.6 24.173 Sprinkler 207 29.41 26.00 5.6 27.575 Sprinkler 208 29.55 26.00 5.6 27.847 Sprinkler 209 29.76 26.00 5.6 28.246 Sprinkler 210 29.97 26.00 5.6 28.648 Sprinkler 211 30.99 26.00 5.6 30.621 Sprinkler 212 30.79 26.00 5.6 30.237 Sprinkler 213 30.98 26.00 5.6 30.608 Sprinkler 214 31.49 26.00 5.6 31.623 Sprinkler 215 33.19 26.00 5.6 35.117 Sprinkler 216 33.02 26.00 5.6 34.766 Sprinkler 218 33.17 26.00 5.6 35.089 Sprinkler 219 36.66 26.00 5.6 42.862 Sprinkler 220 36.81 26.00 5.6 43.216 Sprinkler 221 36.85 26.00 5.6 43.296 c Most Demanding Sprinkler Data (M. © M.E.P.CAD. Inc. $AutoSPRlNK 2020 BETA v16.3.1.0 4/16/2021 11:16:16AM Paae 4 Job Name: Drawingi Remote Area Number: 2 Date: 4/16/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 150.300 128.300 1696.00 143.479 900.59 115.466 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 37 24-1 36.792 38 24'-1 45.132 39 24-1 29.343 40 24-1 29.630 41 24-1 32.542 42 24-1 33.743 43 24-1 37.415 44 24-1 45.384 45 24-1 45.755 47 24-1 45.839 48 24-1 47.553 68 10-0 99.247 B235 0'-6 Gauge 107.859 242 -2-11 109.606 571 12-3 82.649 1 -2-11 Supply 115.466 650.59 201 24-7 Sprinkler 21.556 26.00 202 24-7 Sprinkler 21.693 26.08 203 24-7 Sprinkler 22.792 26.73 ,© M.E.P.CAD, Inc. jAutoSPRlNK 2020 BETA 4/16/2021 11:16:18AM Page 5 Job Name: Drawingi Remote Area Number: 2 Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 204 24-7 Sprinkler 22.936 26.82 205 24-7 Sprinkler 23.648 27.23 206 24-7 Sprinkler 24.173 27.53 207 24-8% Sprinkler 27.575 29.41 208 24-81/2 Sprinkler 27.847 29.55 209 24-7 Sprinkler 28.246 29.76 210 24-7 Sprinkler 28.648 29.97 211 248h/2 Sprinkler 30.621 30.99 212 24'-7 Sprinkler 30.237 30.79 213 24-7 Sprinkler 30.608 30.98 214 24-11 Sprinkler 31.623 31.49 215 24-11 Sprinkler 35.117 33.19 216 24-7 Sprinkler 34.766 33.02 218 24'-7 Sprinkler 35.089 33.17 219 24-8% Sprinkler 42.862 36.66 220 248h/2 Sprinkler 43.216 36.81 221 24-81/2 Sprinkler 43.296 36.85 222 24-81/2 Sprinkler 44.931 37.54 2 -2'- 11 114.321 3 24-1 22.936 4 -2-11 109.842 5 -2-11 110.038 6 -2'-11 113.426 1&©M.E.P.CAD, Inc. IlAutoSPRINK 2020 BETA' 4/16/2021 11:16:18AM Page 6 Job Name: Drawng1 Remote Area Number: 2 Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 7 -2'-ll 113.661 9 -2'-ll 114.577 10 -2-11 114.665 11 -2-11 114.407 14 24-1 23.079 15 -2-11 114.720 17 -2-11 114.774 21 -2-11 114.396 22 24-1 25.682 24 24-1 30.378 25 24-1 32.433 26 24-1 37.136 27 24-1 45.418 28 24-1 46.292 29 -2-11 114.839 30 24'-1 48.020 31 24-1 24.233 32 24-1 24.384 33 24'-1 25.132 34 24'-1 29.956 35 24-1 32.045 J©M.E.P.CAD, Inc. ]AutoSPRlNK 2020 BETA 4/16/2021 11:16:18AM Pacie7 Job Name: Drawingi Remote Area Number: 2 Date: 4/16/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as Fitting (Foot) _________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) ______________ Friction(Pf) 201 24-7 5.6 26.00 1 (See Notes) 0-6 120 21.556 '•••Route .''.. Sprinkler, P0(5-0) 5-0 0.211435 0.217 3 24'-1 26.00 1.0490 5-6 1.163 3 24-1 11/2 6-9 120 22.936 0.021212 14 24-1 26.00 1.6820 6-9 0.143 14 24'-1 26.08 11/2 (See Notes) 14'1Y2 120 23.079 Flow (q) from Route 2 4E(4-111/,) 19-9% 0.076693 22 24-1 52.08 1.6820 33-11% 2.603 22 24'-1 27.53 11/2 (See Notes) 811/2 120 25.682 Flow (q) from Route 6 4E(4111/2) 19-9% 0.168160 24 24-1 79.62 1.6820 27-11 4.695 24 24-1 29.97 1/2 6'-g 120 30.378 Flow (q) from Route 10 0.303701 25 24-1 109.59 1.6820 6-9 2.055 25 24'l 30.98 11/2 9'-9 120 32.433 Flow (q) from Route 12 0.481374 0.003 26 24-1 140.57 1.6820 9-9 4.700 26 24-1 33.17 11/2 (See Notes) 11 9 120 37.136 Flow (q) from Route 16 P0(9-11 ) 9-11 0.712369 -0.003 27 24-1 173.74 1.6820 11-7% 8.285 27 24'l 174.36 3 8'-6 120 4186 45. Flow (q) from Route 3 0.102670 28 24-1 348.10 3.2600 8-6 0.874 28 24-1 154.62 + 36.8 3 7'-6 120 46.292 Flow (q) from Route 7 and 20 0.230982 30 24-1 539.57 3.2600 7-6 1.728 30 24'-1 73.48 + 37.54 3 (See Notes) 56'9 120 48.020 Flow (q) from Route 18 and 21 E(9'-5), T(20-2), EE(4'-O%) 33-7 0.326512 5.130 571 12'-3 650.59 3.2600 90-4 29.498 571 12'-3 4 (See Notes) 99'8% 120 82.649 2EE(5'-3), T(26-4), 3E(13-2) 76-41/2 0.088725 1 0.975 68 10-0 i650.59 4.2600 176-1 15.622 , © M.E.P.CAD, Inc. 14 AutoSPRINK 2020 BETA v16.3.1.0 2 4/16/2021 11:16:20AM Page 8 Job Name: Drawing I Remote Area Number: 2 Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as nAgfiA uhi Fitting (F oot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ______________ Friction(Pf) 68 10-0 4 (See Notes) 8'10/2 120 99.247 ALV(28'-O), BV(16-8%), BOR 448h/2 0.083823 4.119 B235 0'-6 650.59 4.3100 5371/ 4.494 B235 0-6 6 (See Notes) 3'5 120 107.859 E(17-7) 17'-7 0.012631 1.481 242 -2-11 650.59 6.3570 21-0 0.265 242 -2-11 6 (See Notes) 11 0 150 109.606 E(11'-5Y2) 115h/z 0.019377 -0.005 4 -2-11 650.59 5.3490 12-5% 0.241 4 -2-11 6 (See Notes) 53 140 109.842 LtE(14'-2) 14-2 0.010078 5 -2-11 650.59 6.2800 19-5% 0.196 5 -2-11 6 (See Notes) 9'6 120 110.038 2GV(0'-O), 2T(0'-O), BFP(-3.50 7), E(17'-7) 17-7 0.012631 -0.000 6 -2-11 650.59 6.3570 27'-1 3.388 6 -2'-11 6 (See Notes) 13 140 113.426 E(22'-l) 22-1 0.010078 7 -2-11 650.59 6.2800 23-4 0.235 7 -2-11 6 (See Notes) 1821/2 140 113.661 T(47'-31/2) 4731/2 0.010078 2 -2-11 650.59 6.2800 65'-51/2 0.660 2 -2-11 10 (See Notes) 3433Y2 150 114.321 T(37'-6) 37-6 0.000226 11 -2-11 209.85 8.6780 38091/2 0.086 11 4-11 8 (See Notes) 4327% 150 114.407 T(18'-81/2) 1881/2 0.000962 -0.003 29 -2'-11 209.85 6.4470 451-31/2 0.434 29 4-11 8 (See Notes) 65191/2 150 114.839 5 0.000962 0.000 1 -2'-11 209.85 6.4470 651-91/2 0.627 250.00 115.466 Hose Allowance At Source Total(Pt) Route 1 1 900.59 &@ M.E.P.CAD, Inc. MAutoSPRINK 2020 BETA v16.3. 1.0 2 4/16/2021 11:16:20AM Page 9 Job Name: Drawingi Remote Area Number: 2 Date: 4/16/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (N) and shown as npgntis,p Fitting (Fo ot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ______________ Friction(Pf) 202 24-7 5.6 26.08 1 (See Notes) 0-6 120 21.693 'Route2''''' Sprinkler, PO(5'-O) 5-0 0.212674 0.217 14 24-1 26.08 1.0490 5 '-6 1.170 -T- 23.079 Total(Pt) Route 2 203 24-7 5.6 26.73 1 (See Notes) 0-6 120 22.792 •••• Route 3 Sprinkler, P0(5-U) 5'-0 0.222624 0.217 31 24-1 26.73 1.0490 5 '-6 1.224 31 24-1 1 Y2 6-9 120 24.233 0.022334 -0.000 32 24-1 26.73 1.6820 6-9 0.151 32 24'-1 26.82 11/2 9'3 120 24.384 Flow (q) from Route 4 0.080751 33 24'-1 53.55 1.6820 9-3 0.748 33 24-1 27.23 1% (See Notes) 811/2 120 25.132 Flow (q) from Route 5 4E(4--1 11/2) 1 0.172766 34 24-1 80.79 1.6820 27-11 4.824 34 24-1 29.76 11/2 69 120 29.956 Flow (q) from Route 9 0.308643 35 24-1 110.55 1.6820 6-9 2.089 35 24'-1 30.79 11/2 9-9 120 32.045 Flow (q) from Route ii 0.486279 37 24-1 141.34 1.6820 9-9 4.748 37 24-1 33.02 11/2 (See Notes) 11 9 120 36.792 Flow (q) from Route 15 PO(9'-11) 9-11 0.717076 38 24-1 174.36 1.6820 11-7% 8.339 38 24'-1 3 10-0 120 45.132 0.028574 27 24-1 174.36 3.2600 10-0 0.286 45.418 Total(Pt) Route 3 204 24'-7 5.6 26.82 1 (See Notes) 0-6 T 120 22.936 ••.. Route 4' •' Sprinkler, P0(5-0) t 0.223923 0.217 32 24-1 26.82 1.0490 5'-6 1.232 24.384 Total(Pt) Route 4 ,©M.E.P.CAD, Inc. loAutoSPRINK2020BETA06.3.1.0 2 4/16/2021 11:16:20AM Page 10 Job Name: Drawing 1 Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as naptiwp tiIiip Fitting (F oot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 205 24-7 5.6 27.23 1 (See Notes) 0-6 120 23.648 ••'•' Route 5• 0000 Sprinkler, P0(5-0) 5'0 0.230352 0.217 33 24-1 27.23 1.0490 5-6 1.267 25.132 Total(Pt) Route 5 206 24-7 5.6 27.53 1 (See Notes) 0-6 1 120 24.173 "' Route 6 Sprinkler, P0(5-0) tj 1 0.235073 0.217 22 24-1 27.53 1.0490 5-6 1.293 25.682 Total(Pt) Route 6 207 24-8% 5.6 29.41 1 (See Notes) 0-7% 120 27.575 'eeo Route7 00000 Sprinkler, P0(5-0) 5-0 0.265518 0.274 39 24'-1 29.41 1.0490 5-7% 1.495 39 24-1 1% 10-9 120 29.343 0.026638 40 24'-1 29.41 1.6820 10-9 0.287 40 24'-1 29.55 11/z (See Notes) 10'41/2 120 29.630 Flow (q) from Route 8 4E(4-11%) 19'-9% 0.096468 41 24'-1 58.96 1.6820 30-2 2.912 41 24-1 30.99 11/2 5-81/2 120 32.542 Flow (q) from Route 13 0.210740 42 24-1 89.95 1.6820 5-8% 1.201 42 24-1 31.49 11/2 101-0 120 33.743 Flow (q)from Route 14 0.367226 43 24-1 121.44 1.6820 10-0 3.672 43 24-1 33.19 11/2 (See Notes) 5'61/2 120 37.415 Flow (q) from Route 17 P0(9-11) 9-11 0.574165 28 24-1 154.62 1.6820 15-5% 8.877 46.292 Total(Pt) Route 7 208 24 -81/2 5.6 29.55 1 (See Notes) 0 -71/2 120 27.847 ••.. Route 8 Sprinkler, P0(5-0) 5-0 0.267948 0.274 40 24-1 29.55 1.0490 5'-71/2 1.509 29.630 Total(Pt) Route 8 &@ M.E.P.CAD, Inc. OlAutoSPRINK 2020 BETA v16.3.1.0 2 4/16/2021 11:16:20AM Page 11 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as nppiup nIt.p Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 209 24-7 5.6 29.76 1 (See Notes) 0-6 120 28.246 •• •• • Route 9 •••.• Sprinkler, P0(5-0) 5-0 0.271493 0.217 34 24-1 29.76 1.0490 5'-6 1.493 29.956 Total(Pt) Route 9 210 24-7 5.6 29.97 1 (See Notes) 0-6 120 28.648 ' Route 1O' Sprinkler, P0(5-0) 5'0 0.275066 0.217 24 24-1 29.97 1.0490 5-6 1.513 30.378 Total(Pt) Route 10 212 24'-7 5.6 30.79 1 (See Notes) 0-6 120 30.237 ••••• Route 11 Sprinkler, PO(5'-O) 5'-0 0.289154 0.217 35 24-1 30.79 1.0490 5'-6 1.590 32.045 Total(Pt) Route 11 213 24'-7 5.6 30.98 1 (See Notes) 0-6 1 120 30.608 ••'•' Route 12••••• Sprinkler, P0(5-0) 5-0 t 0.292428 0.217 25 24-1 30.98 1.0490 5-6 1.608 32.433 Total(Pt) Route 12 211 2481/2 5.6 30.99 1 (See Notes) o'-7 1 120 30.621 •• •• Route 13 Sprinkler, P0(5-0) 5'-0 t 0.292541 0.274 41 24'-1 30.99 1.0490 571/2 1.647 32.542 Total(Pt) Route 13 214 24-11 5.6 31.49 1 (See Notes) 01-10 120 31.623 ••••• Route 14'•••• Sprinkler, PO(5'-O) 5-0 0.301393 0.361 42 24'-1 31.49 1.0490 F-10 1.758 33.743 Total(Pt) Route 14 216 24-7 5.6 33.02 1 (See Notes) 0'-6 J 120 34.766 ' •• ' Route 15''.'. Sprinkler, P0(5-0) 5'-0 t 0.328999 0.217 37 24-1 33.02 1.0490 5-6 1.809 36.792 Total(Pt) Route 15 218 24-7 5.6 33.17 1 (See Notes) 0'6 T 120 35.089 'Route 16" Sprinkler, P0(5-0) 5-0 1 0.331821 0.220 26 24-1 33.17 1.0490 5'-6 1.827 37.136 Total(Pt) Route 16 , © M.E.P.CAD, Inc. MAutoSPRINK2020 BETA v16.3.1.0 2 4/16/2021 11:16:20AM Page 12 Job Name: Drawing I Remote Area Number: 2 Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as naptiup ,iIi.p Fitting (Foot) _________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) ______________ Friction(Pf) 215 24-11 5.6 33.19 1 (See Notes) 0-10 120 35.117 ••••'Route17•" Sprinkler, P0(5-0) I 0.332066 0.361 43 24-1 33.19 1.0490 5-10 1.937 37.415 Total(Pt) Route 17 219 24-8% 5.6 36.66 1 (See Notes) 0'-7% 120 42.862 Route 18..... Sprinkler, P0(5-0) 5-0 0.399289 0.274 44 24-1 36.66 1.0490 571/2 2.248 44 24-1 11/2 9'-3 120 45.384 0.040058 45 24'-1 36.66 1.6820 9-3 0.371 45 24'-1 36.81 11/2 (See Notes) 5'8Y2 120 45.755 Flow (q) from Route 19 P0(9-11) 9-11 30 24-1 73.48 1,6820]0.144961 15-7% 2.265 48.020 Total(Pt) Route 18 220 24'-8% 5.6 36.81 1 (See Notes) 0'-7Y2 T 120 43.216 "• Route 19'•'•• Sprinkler, P0(5-0) 5'-0 1 0.402339 0.274 45 24-1 36.81 1.0490 5'71/2 2.266 45.755 Total(Pt) Route 19 221 24-8% 5.6 36.85 1 (See Notes) 0'-7% 120 43.296 ..... Route 20'•'•' Sprinkler, PO(5'-O) 5-0 0.403028 0.274 47 24'-1 36.85 1.0490 571,4 2.270 47 24-1 11/2 (See Notes) 131/2 120 45.839 P0(9-11) 9-11 0.040433 28 24-1 36.85 1.6820 11-2% 0.453 46.292 Total(Pt) Route 20 222 24-81/2 5.6 37.54 1 (See Notes) 0'71/2 120 44.931 •••Route21•• Sprinkler, P0(5-U) 5-0 0.417087 0.274 48 24'-1 37.54 1.0490 5'71/2 2.349 48 24-1 11/2 (See Notes) 1'3 120 47.553 P0(9-11) 9'-11 0.041844 30 24-1 37.54 1.6820 11-2 0.467 48.020 Total(Pt) Route 21 ( © M.E.P.CAD, Inc. Tifl AutoSPRINK 2020 BETA v16.3.1.0 2 4/16/2021 11:16:20AM Page 13 Job Name: Drawing 1 Remote Area Number: 2 Date: 4/16/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as 0o0fiwa s,f1I,ia Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 9 211 440.73 10 9791/2 150 114.577 •• •• • Route 22'''.' Flow (q) from Route 23 0.000893 10 -2-11 440.73 8.6780 9791/2 0.087 10 -2'- 11 10 (See Notes) 541 150 114.665 EE(8'-3) 8-3 0.000893 15 -2-11 440.73 8.6780 62-4 0.056 15 -2-11 10 (See Notes) 2291/2 150 114.720 T(37-6) 37-6 0.000893 17 -2-11 440.73 8.6780 0.054 17 -2-11 8 (See Notes) 1636h/2 150 114.774 6, T(16-81/2) 18-81/2 0.003798 1 -2-11 440.73 6.4470 182'-3 0.692 115.466 Total(Pt) Route 22 2 -2-11 209.85 10 85'-1 150 114.321 '''' Route 23••••• Flow (q) from Route I 0.000893 -0.002 21 -2-11 440.73 8.6780 85-1 0.076 21 -2'- 11 10 (See Notes) 1965 150 114.396 EE(8-3) 8-3 0.000893 -0.001 9 -2'-11 440.73 8.6780 204-8 0.183 114.577 Total(Pt) Route 23 (, © M.E.P.CAD, Inc. W AutoSPRINK 2020 BETA v16.3.1.0 2 4/16/2021 11:16:20AM Page 14 Job Name: Drawingi Remote Area Number: 2 Date: 4/16/2021 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) I IC Value Multiplier Actual Inside Diameter 4.87 Factor Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter) - ac Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111h° Elbow Ee2 221/2* Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap . © M.E.P.CAD, Inc. M AutoSPRINK 2020 BETA v16.3. 1.0 2 4/16/2021 11:16:20AM Page 15 Hydraulic Calculations for Project Name: Drawing I Location:,, Drawing Name: 21176 - Beacon Phase lI_FP design A-7720 Design Remote Area Number: 3 Remote Area Location: L2 Occupancy Classification: Light Hazard Calculation Date: 4/16/2021 Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: O.logpmlft2 I 500ft2 (Actual 474ft2) 130ft2 Pendent 7 0 N/Agpm at Node: N/A 100.00 at Node: I Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 216.84 @62.902 Type of System: Volume of Dry/PreAction/Antifreeze/OtherA N/A Allowance at Source (Safety Margin = 86.909) Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes Automatic peaking results Left: N/A Right: N/A (MM.E.P.CAD, Inc. AutoSPRlNK 2020 BETA v1 6.3. 1.0 3 4/16/202111:32:24AM Page 1 3500 0 350 700 1 2800 3150 1400 2100 1750 2450 Flow - gpm Date: 4/16/2021 180 160 100 80 LMI riro 20 Job Name: Drawingi Remote Area Number: 3 200- - Supply Summary Sheet Node: 1 Available Supply Static Pressure 150.300 216.84@110________ 1696.00 @ 128.300 1184 216.84 62.902Zvi with Hose Allowance at Source__ System emand cjve Hydraulic Graph N 1.85 (&© M.E.P.CAD, Inc. 11 AutoSPRINK 2020 BETA 06.3.1.0 4/16/2021 11:32:26AM Paqe 2 Job Name: Drawingi Remote Area Number: 3 Date: 4/16/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 150.300 128.300 1696.00 149.810 216.84 62.902 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -2-11 Supply 62.902 116.84 46 23-0 Sprinkler 7.082 14.90 69 23-0 Sprinkler 8.023 15.86 70 23-0 Sprinkler 9.146 16.94 71 23-0 Sprinkler 10.916 18.50 72 23-0 Sprinkler 13.543 20.61 1368 23-0 Sprinkler 7.000 14.82 1369 23-0 Sprinkler 7.381 15.21 2 -2'- 11 62.856 4 -2-11 59.035 5 -2-11 59.043 6 -2-11 62.819 7 -2-11 62.829 9 -2-11 62.864 10 -2-11 62.868 11 -2'- 11 62.860 15 -2-11 62.870 17 -2'-11 62.873 21 -2-11 62.858 1A,©M.E.P.CAD, Inc. jIJAutoSPRlNK 2020 BETA' 4/16/2021 11:32:29AM Page 5 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 29 -2'- 11 62.875 36 2401/2 44.241 68 10-0 53.232 B235 0-6 Gauge 57.538 242 -2-11 59.030 571 12'-3 51.604 .,© M.E.P.CAD, Inc. jitlAutoSPRINK 2020 BETA' 4/16/2021 11:32:29AM Page 6 -Job Name: Drawingl Remote Area Number: 3 Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as npgfiwp unliia Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 1368 23-0 5.6 14.82 11/2 (See Notes) 111-0 120 7.000 *sees Route l Sprinkler 0.007495 46 23-0 14.82 1.6820 11-0 0.082 46 23-0 5.6 14.90 11/2 (See Notes) 110 120 7.082 Sprinkler 0.027165 1369 23-0 29.72 1.6820 11-0 0.299 1369 23-0 5.6 15.21 11/2 (See Notes) 110 120 7.381 Sprinkler 0.058363 69 23-0 44.93 1.6820 11,-U 0.642 69 23-0 5.6 15.86 11/2 (See Notes) 11,-0 120 8.023 Sprinkler 0.102105 70 23-0 60.80 1.6820 11-0 1.123 70 23-0 5.6 16.94 11/2 (See Notes) 110 120 9.146 Sprinkler 0.160876 71 23-0 77.73 1.6820 11-0 1.770 71 23-0 5.6 18.50 11/2 (See Notes) 111 0 120 10.916 Sprinkler 0.238803 72 23-0 96.23 1.6820 11-0 2.627 72 23'-0 5.6 20.61 ic (See Notes) 36'71/2 120 13.543 Sprinkler, 9E(4'-111/2),P0(9-11) 54-5% 0.341934 -0.445 36 24-0% 116.84 1.6820 91-1 31.143 36 240% 3 (See Notes) 83'-8% 120 44.241 E(9'-S), C(20'-2), T(20'-2), EE (4-0%) 82-0 0.013625 5.105 571 12'-3 116.84 3.2600 165'-8% 2.258 571 12-3 4 (See Notes) 99'-8% 120 51.604 2EE(5'-3), T(26'4), 3E(13'-2) 76'41/2 0.003702 0.975 68 10-0 116.84 4.2600 176-1 0.652 68 10-0 4 (See Notes) 8'-101/2 120 53.232 ALV(28'-U), BV(16-81/2), BOR 44-81/2 0.003498 4.119 B235 0-6 116.84 4.3100 53-71/2 0.188 B235 0-6 6 (See Notes) 3'5 120 57.538 E(17'-7) 17-7 0.000527 1.481 242 -2-11 116.84 6.3570 21-0 0.011 , © M.E.P.CAD, Inc. AutoSPRlNK 2020 BETA 06.3.1.0 3 4/16/2021 11:32:30AM Page 7 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 242 -2'-11 6 (See Notes) 1-0 150 59.030 E(11-51/2) 1151/2 0.000809 -0.005 4 -2-11 116.84 5.3490 12-5% 0.010 4 -2-11 6 (See Notes) 53 140 59.035 LtE(14-2) 14-2 0.000421 5 -2-11 116.84 6.2800 19 51/2 0.008 5 -2'-11 6 (See Notes) 96 120 59.043 2GV(0-0), 2T(0'-O), BFP(-3.79 2), E(17'-7) 17'-7 0.000527 -0.000 6 -2'-11 116.84 6.3570 27-1 3.776 6 -2'-11 6 (See Notes) 1'3 140 62.819 E(22'-l) 22'-1 0.000421 7 -2-11 116.84 6.2800 23-4 0.010 7 -2-11 6 (See Notes) 18'2% 140 62.829 T(47'-3114) 4731/ 0.000421 2 -2-11 116.84 6.2800 65'- 5Y2 0.028 2 -2-11 10 (See Notes) 343'3Y2 150 62.856 T(37'-6) 37-6 0.000009 11 -2-11 37.69 8.6780 380-9% 0.004 11 -2-11 8 (See Notes) 432'J1/2 150 62.860 T(18-81/2) 18'-8% 0.000040 -0.003 29 -2-11 37.69 6.4470 4513h/2 0.018 29 -2-11 8 (See Notes) 6519h/2 150 62.875 S 0.000040 0.000 1 -2-11 37.69 6.4470 651'-9% 0.026 100.00 62.902 Hose Allowance At Source Total(Pt) Route 1 1 216.84 9 -2-11 79.15 10 97-9% 150 62.864 •• •• Route 2 - Flow (q) from Route 3 0.000037 10 -2-11 79.15 8.6780 9791/2 0.004 10 -2-11 10 (See Notes) 54'1 150 62.868 EE(8'-3) 8'-3 0.000037 15 -2-11 79.15 8.6780 62-4 0.002 , © M.E.P.CAD, Inc. jfi AutoSPRINK 2020 BETA v16.3.1.0 3 4/16/2021 11:32:30AM Page 8 Job Name: Drawingl Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) _________ C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as flag*iwp tIIIla ____ ____________ Fitting (Fo ot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 15 -2-11 10 (See Notes) 229h/2 150 62.870 T(37'-6) 37-6 0.000037 17 -2'-11 79.15 8.6780 60-3% 0.002 17 -2-11 8 (See Notes) 163'61/2 150 62.873 5, T(18'-8%) 18-8% 0.000158 1 -2-11 79.15 6.4470 182-3 0.029 62.902 Total(Pt) Route 2 2 -2'- 11 37.69 10 85'-1 150 62.856 ••'•'Route3••••' Flow (q) from Route 1 0.000037 -0.002 21 -2'- 11 79.15 8.6780 85-1 0.003 21 -2'-11 10 (See Notes) 196'5 150 62.858 EE(8'-3) 8-3 0.000037 -0.001 9 -2'- 11 79.15 8.6780 204-8 0.008 62.864 Total(Pt) Route 3 ,,© M.E.P.CAD, Inc. JjAutoSPRINK 2020 BETA06.3.1.0 3 4/16/2021 11:32:30AM Page 9 'Job Name: Drawingi Remote Area Number: 3 Date: 4/16/2021 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) II C Value Multiplier / Actual Inside Diameter 4 Factor .87 Value Of C 100 130 140 150 I = Schedule 40 Steel Pipe Inside Diameter) Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 221/2* Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,© M.E.P.CAD, Inc. jUAutoSPRlNK 2020 BETA v16.3.1.0 3 4/16/2021 11:32:30AM Page 10 Hydraulic Calculations for Project Name: Drawingi Location: Drawing Name: 21176 - Beacon Phase ll_FP design A-7720 Design Remote Area Number: 4 Remote Area Location: LI Occupancy Classification: Ordinary Group II Calculation Date: 4/16/2021 Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm/ft2 1500ft2 (Actual I581ft2) 130ft2 Upright 16 0 N/Agpm at Node: N/A 250.00 at Node: 1 Type Allowance at Source (Safety Margin = 29.725) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 753.23 @ 115.674 Type of System: Volume of Dry/PreAction/Antifreeze/Other.A N/A Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: 115.674 Right: 115.674 1L©M.E.P.CAD, Inc. 1jIAutoSPRINK 2020 BETA 06.3.1.0 4 4/16/202111:14:56AM Page 1 Hydraulic Graph Job Name: Drawing 1 N 1.85 Remote Area Number: 4 Date: 4/16/2021 200 —: Supply Summary Sheet 180 Node: I H - - ______ ________ _________ ____________ ______________ ________________ 160_: Static Pressure 150.300 145.399 1696.00 @ 128.300 - 503.23c115.674 ---S 53.23 with Hose Allowance 100— (I) U) - 7 at Source 80- 60 - System_demand curve - 40 20L0 IIIIIII IIIIIIIl IlIIIIt 111111 III 1111111 II I I I I I I I I I I I I I I I I I I I I I I I 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Flow - gpm &© M.E.P.CAD, Inc. tj AutoSPRINK 2020 BETA v16.3.1.0 4/16/2021 11:14:58AM Paqe 2 III Summary Of Outfiowing Devices I Job Number: 1 ReDort DescriDtion: Ordinary Grouo II (4 Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) - Sprinkler 401 26.00 26.00 5.6 21.556 Sprinkler 402 26.61 26.00 5.6 22.577 Sprinkler 403 27.40 26.00 5.6 23.936 Sprinkler 404 29.37 26.00 5.6 27.505 Sprinkler 405 29.94 26.00 5.6 28.593 Sprinkler 407 30.29 26.00 5.6 29.247 Sprinkler 408 30.33 26.00 5.6 29.341 Sprinkler 409 30.68 26.00 5.6 30.009 Sprinkler 410 31.38 26.00 5.6 31.396 Sprinkler 411 31.78 26.00 5.6 32.208 Sprinkler 412 32.56 26.00 5.6 33.806 Sprinkler 413 33.58 26.00 5.6 35.961 Sprinkler 414 34.01 26.00 5.6 36.881 Sprinkler 415 36.21 26.00 5.6 41.800 Sprinkler 416 36.32 26.00 5.6 42.068 Sprinkler 417 36.78 26.00 5.6 43.133 4 Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. M AutoSPRlNK 2020 BETA v16.3. 1.0 4/16/2021 11:14:59AM Page 4 Job Name: Drawingl Remote Area Number: 4 Date: 4/16/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) © (gpm) Required Pressure (psi) Water Supply 150.300 128.300 1696.00 145.399 753.23 115.674 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -2-11 Supply 115.674 503.23 401 9-11% Sprinkler 21.556 26.00 402 10-5 Sprinkler 22.577 26.61 403 10'-3 Sprinkler 23.936 27.40 404 10-0% Sprinkler 27.505 29.37 405 10'-S% Sprinkler 28.593 29.94 407 10-3 Sprinkler 29.247 30.29 408 10-5% Sprinkler 29.341 30.33 409 10-3 Sprinkler 30.009 30.68 410 10-0% Sprinkler 31.396 31.38 411 1001/2 Sprinkler 32.208 31.78 412 9'-10 Sprinkler 33.806 32.56 413 9-10 Sprinkler 35.961 33.58 414 9-10 Sprinkler 36.881 34.01 415 9-71/2 Sprinkler 41.800 36.21 416 971/2 Sprinkler 42.068 36.32 417 9-71/2 Sprinkler 43.133 36.78 2 -2'-11 114.963 4 -2-11 110.967 J©M.E.P.CAD, Inc. IlAutoSPRINK 2020 BETA 4/16/2021 11:15:01AM Page 5 Job Name: Drawingi Remote Area Number: 4 Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 5 -2'-ll 111.089 6 -2'-11 114.407 7 -2-11 114.553 9 -2-11 115.121 10 -2-11 115.176 11 -2-11 115.017 15 -2'-11 115.210 17 -2'- 11 115.244 21 -2-11 115.009 29 -2-11 115.284 49 9-11% 23.981 50 9'-11 24.007 51 9-9 25.433 52 9-61/2 29.179 53 9-4 35.785 54 9-3% 45.316 55 9-3% 45.603 56 9'-3% 46.748 57 9-11% 30.320 58 9-9 31.006 59 9-6% 33.259 60 9-4 38.045 61 9'-111/2 31.104 ,© M.E.P.CAD, Inc. [1]AutoSPRlNK 2020 BETA' 4/16/2021 11:15:01AM Page 6 Job Name: Drawingi Remote Area Number: 4 Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 62 9-9 31.805 63 9-6% 34.111 64 9'-4 39.009 65 9'-l% 44.163 66 91h/2 44.443 67 9-1% 45.558 68 10-0 102.263 B235 0-6 Gauge 109.175 242 -2-11 110.822 571 12-3 91.573 ,©M.E.P.CAD, Inc. iflAutoSPRINK 2020 BETA' 4/16/2021 11:15:01AM Page 7 -Job Name: Drawingi Remote Area Number: 4 Date: 4/16/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as , ____ _____________ Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 401 911h/2 5.6 26.00 1 (See Notes) 4'-5% 120 21.556 Route1 Sprinkler, E(2'-O), PO(5'-O) 7-0 0.211435 49 9'- 111/2 26.00 1.0490 1151/2 2.425 49 9-11% 1% 0'-6 120 23.981 0.044894 0.004 50 9'-11 26.00 1.4420 0-6 0.022 50 9'-11 26.61 11/4 8-2 120 24.007 Flow (q)from Route 2 0.165366 0.075 51 9-9 52.61 1.4420 8-2 1.351 51 9-9 27.40 1¼ 10-2 120 25.433 Flow (q) from Route 3 0.359144 0.094 52 9'-6Y2 80.01 1.4420 10-2 3.652 52 9-6% 29.37 11/4 10-2 120 29.179 Flow (q) from Route 4 0.640464 0.094 53 9'-4 109.38 1.4420 10-2 6.513 53 9'-4 32.56 1¼ (See Notes) 11 9 120 35.785 Flow (q) from Route 11 P0(7-5) 7-5 1.037194 0.016 54 9-31/2 141.94 1.4420 9-2 9.515 54 9'..31A 36.21 3 9-8 120 45.316 Flow (q) from Route 14 0.029730 -0.000 55 9'31/2 178.14 3.2600 9'-8 0.287 55 9-31/2 25.19 + 36.3 3 11-8 120 45.603 Flow (q) from Route Sand 15 0.098106 -0.000 56 9'-3% 339.65 3.2600 11-8 1.145 56 9-31/2 126.80 + 36.7 3 (See Notes) 204'3 120 46.748 Flow (q) from Route 7 and 16 2E(9'-5), EE(4'-01/2) 22-10 0.203026 -1.282 571 12-3 503.23 3.2600 227-1 46.108 571 12'-3 4 (See Notes) 99'8% 120 91.573 2EE(5'-3), T(26'-4), 3E(13'-2) 76-41/2 0.055169 0.975 68 101-0 503.23 4.2600 176-1 9.714 68 10-0 4 (See Notes) 8'101/2 120 102.263 ALV(28'-O), BV(16-81/2), BOR 44-8% 0.052122 4.119 B235 0-6 503.23 4.3100 53-71/2 2.794 ,© M.E.P.CAD, Inc. AutoSPRINK 2020 BETA v16.3.1.O 4 4/16/2021 11:15:03AM Page 8 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as Fitting (Foot) Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) _______________ Friction(Pf) B235 0-6 6 (See Notes) 3'5 120 109.175 E(17'-7) 17-7 0.007854 1.481 242 -2'- 11 503.23 6.3570 21-0 0.165 242 -2-11 6 (See Notes) 10 150 110.822 E(11'-51/2) 1151/2 0.012049 -0.005 4 -2-11 503.23 5.3490 12'-51h 0.150 4 -2-11 6 (See Notes) 5'3 140 110.967 LtE(14'-2) 14-2 0.006266 5 -2-11 503.23 6.2800 19-5% 0.122 5 -2-11 6 (See Notes) 96 120 111.089 2GV(0'-O), 2T(0'-O), BFP(-3.50 7), E(17'-7) 17-7 0.007854 -0.000 6 -2-11 503.23 6.3570 27-1 3.318 6 -2-11 6 (See Notes) 1'3 140 114.407 E(22'-l) 22'-1 0.006266 7 -2-11 503.23 6.2800 23-4 0.146 7 -2-11 6 (See Notes) 18'2% 140 114.553 4731/ 0.006266 2 -2'-ll 503.23 6.2800 T(47'-31/2)65-51/2 0.410 2 -2-11 10 (See Notes) 343'3% 150 114.963 T(37'-6) 37-6 0.000141 11 -2'-11 162.32 8.6780 3809h/2 0.054 11 -2'-ll 8 (See Notes) 432'71/2 150 115.017 T(18'-8%) 18-8% 0.000598 -0.003 29 -2-11 162.32 6.4470 451'-3Y2 0.270 29 -2-11 8 (See Notes) 651'91/2 150 115.284 0.000598 F 0.000 1 -2-11 162.32 6.4470 651-9% 0.390 250.00 115.674 Hose Allowance At Source Total(Pt) Route 1 1 753.23 402 10,-5 5.6 26.61 1 (See Notes) 0-6 120 22.577 •• •• Route 2 Sprinkler, P0(5-0) 5-0 0.220682 0.217 50 9-11 26.61 1.0490 5-6 1.214 ,©M.E.P.CAD, Inc. MAutoSPRINK2020 BETA 06.3.1.0 4 4/16/2021 11:15:03AM Page 9 -Job Name: Drawingi Remote Area Number: 4 Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Devices Fittings & Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as naJtiun .iIi.ô Fitting (Foot) _________ Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ______________ Friction(Pf) 24.007 J Total(Pt) Route 2 403 10-3 5.6 27.40 1 (See Notes) 0-6 120 23.936 ''Route Sprinkler, P0(5-0) 5-0 0.232938 0.217 51 9-9 27.40 1.0490 5'-6 1.281 25.433 Total(Pt) Route 3 404 1001/2 5.6 29.37 1 (See Notes) 0'-6 120 27.505 ' Route 4•• •• Sprinkler, P0(5-0) 5-0 0.264903 0.217 52 9'-6% 29.37 1.0490 5 '-6 1.457 29.179 Total(Pt) Route 4 405 10'-5Y2 5.6 29.94 1 (See Notes) o'6 120 28.593 ''•Route5'•'•' Sprinkler, P0(5-0) 5-0 0.274576 0.217 57 9-11% 29.94 1.0490 5-6 1.510 57 9-11% 11/4 10'-2 120 30.320 0.058301 0.094 58 9-9 29.94 1.4420 10-2 0.593 58 91-9 30.29 1 10'-2 120 31.006 Flow (q) from Route 6 0.212393 0.094 59 9-61/2 60.23 1.4420 10-2 2.160 59 9-61/2 31.38 10'-2 120 33.259 Flow (q) from Route 9 0.461388 0.094 60 9-4 91.61 1.4420 10-2 4.692 60 9'-4 33.58 11,/4 (See Notes) 1-9 120 38.045 Flow (q) from Route 12 P0(7-5) 7-5 0.822229 0.016 55 931/ 125.19 1.4420 9-2 7.543 45.603 Total(Pt) Route 5 407 10-3 5.6 30.29 1 (See I Notes) 1 0'-6 120 29.247 '•••Route6•"•• Sprinkler, t 5'-0 0.280383 0.217 58 9-9 30.29 1.0490 5-6 P0(5-0) 1.542 31.006 Total(Pt) Route 6 408 105h/2 5.6 30.33 1 (See T Notes) 0-6 120 29.341 •••••Route7••••' Sprinkler, PO(5'-O) 5-0 0.281216 0.217 61 9-11% 30.33 1.0490 5'-6 1 1.547 L J ©M.E.P.CAD, Inc. MAutoSPRINK 2020 BETA 06.3.1.0 4 4/16/2021 11:15:03AM Page 10 Job Name: Drawingi Remote Area Number: 4 Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P1) and shown as npgtis,p uIu.a Fitting (Foot) _________ Loss Per Unit Pf Friction (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 61 9111,4 1¼ 10-2 120 31.104 0.059711 0.093 62 9-9 30.33 1.4420 10'-2 0.607 62 9-9 30.68 1¼ 10'-2 120 31.805 Flow (q) from Route 8 0.217518 0.093 63 96h/2 61.01 1.4420 10-2 2.212 63 9'-61/2 31.78 1 10-2 120 34.111 Flow (q) from Route 10 0.472483 0.093 64 9-4 92.79 1.4420 10'-2 4.805 64 9-4 34.01 11/4 (See Notes) 19 120 39.009 Flow (q) from Route 13 P0(7-5) 7-5 0.841911 0.016 56 9'-3¼ 126.80 1.4420 9 -2 7.723 46.748 Total(Pt) Route 7 409 103 5.6 30.68 1 (See Notes) 0-6 120 30.009 •••••Route8•'•'• Sprinkler, P0(5-0) 5-0 0.287133 0.217 62 9-9 30.68 1.0490 5 -6 1.579 31.805 Total(Pt) Route 8 71 410 10-0% 5.6 31.38 1 (See T Notes) 1 0-6 120 31.396 '' ' Route 9••.'• Sprinkler, 5-0 0.299387 0.217 59 9'-6% 31.38 1.0490 5'-6 P0(5-0) 1.647 33.259 Total(Pt) Route 9 411 1001/2 5.6 31.78 1 (See Notes) 0'-6 120 32.208 ''' 'Route 10..... Sprinkler, P0(5-0) 5'-0 0.306541 0.217 63 961/2 31.78 1.0490 5'-6 1.686 34.111 Total(Pt) Route 10 412 9-10 5.6 32.56 1 (See Notes) 0-6 1 120 33.806 Route ll"' Sprinkler, P0(5-0) 0.320582 0.217 53 9-4 32.56 1.0490 5'-6 1.763 35.785 Total(Pt) Route 11 413 9-10 5.6 33.58 1 (See Notes) 0'6 1 120 35.961 '••• Route 12••••' Sprinkler, P0(5-0) - 0.339445 0.217 60 9-4 33.58 1.0490 5-6 1.867 38.045 Total(Pt) Route 12 &@ M.E.P.CAD, Inc. AutoSPRlNK 2020 BETA v16.3. 1.0 4 4/16/2021 11:15:03AM Page 11 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Pipe Information Node 1 Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting!Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (N) and shown as p npgptiup ,,.Ii.p Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 414 9'-10 5.6 34.01 1 (See Notes) 0-6 120 36.881 Route 13'''. Sprinkler, PO(5'-O) 5-0 0.347469 0.217 64 9'-4 34.01 1.0490 5 '-6 1.911 39.009 Total(Pt) Route 13 415 971,4 5.6 36.21 1 (See Notes) 0-6 120 41.800 ••••• Route 14••'•' Sprinkler, P0(5-0) 5-0 0.390134 0.217 65 9-1% 36.21 1.0490 5-6 2.146 65 9-1% 11/4 (See Notes) 7'5 120 44.163 P0(7'S) r14-10% 0.082838 -0.078 54 9-3% -5~: 36.21 1.4420 1.231 45.316 Total(Pt) Route 14 416 971,4 5.6 36.32 1 (See Notes) 0-6 120 42.068 ••'•• Route 15'•'•• Sprinkler, P0(5-U) 5-0 0.392442 0.217 66 9-1% 36.32 1.0490 5-6 2.158 66 9-1% 11/4 (See Notes) 75 120 44.443 P0(7 5) 0.083328 -0.078 55 9-31/2 36.32 1.4420 14-101/2 1.238 45.603 Total(Pt) Route 15 417 9-7% 5.6 36.78 1 (See Notes) 0'-6 120 43.133 •••• Route 16..... Sprinkler, P0(5-U) 5'-0 0.401624 0.217 67 9-1% 36.78 1.0490 5'-6 2.209 67 9-1% 11/4 (See Notes) 7'5 120 45.558 P0(7-5) 0.085278 -0.077 56 9-31/2 36.78 1.4420 14'-101/2 1.267 46.748 Total(Pt) Route 16 9 -2'-11 340.91 10 97-91/2 150 115.121 ' Route 179•9•• Flow (q) from Route 18 0000555 10 -2-11 340.91 8.6780 97'-91/2 0.054 10 -2-11 10 (See Notes) 541 150 115.176 EE(8'-3) 8-3 0.000555 15 -2'-11 340.91 8.6780 62'-4 0.035 &@ M.E.P.CAD, Inc. 41 AutoSPRINK 2020 BETA v16.3.1.0 4 4/16/2021 11:15:03AM Page 12 'Jab Name: Drawingi Remote Area Number: 4 Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 15 -2'-11 10 (See Notes) 2291/2 150 115.210 T(37'-6) 37-6 0.000555 17 -2-11 340.91 8.6780 60'-3% 0.033 17 -2-11 8 (See Notes) 16361/2 150 115.244 S, T(18'-81/4 188h/2 0.002361 1 -2-11 340.91 6.4470 182'-3 0.430 115.674 Total(Pt) Route 17 2 -2'-1 1 162.32 10 85-1 150 114.963 Route 18..... Flow (q) from Route 1 0.000555 -0.002 21 -2-11 340.91 8.6780 85-1 0.047 21 -2-11 10 (See Notes) 1965 150 115.009 EE(8'-3) 8'-3 0.000555 -0.001 9 -2-11 340.91 8.6780 204-8 0.114 115.121 Total(Pt) Route 18 , © M.E.P.CAD, Inc. AOAutoSPRINK 2020 BETA v16.3.1 .0 4 4/16/2021 11:15:03AM Page 13 -Job Name: Drawing I Remote Area Number: 4 Date: 4/16/2021 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) I IC Value Multiplier / Actual Inside Diameter .. 4.87 Value Of C 100 130 140 150 I . . I =Factor Schedule 40 Steel Pipe Inside Diameter) Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/40 Elbow Ee2 22%° Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. iJAutoSPRINK 2020 BETA v16.3.1.0 4 4/16/2021 11:15:02AM Page 14 Hydraulic Calculations for Project Name: Drawingi Location: Drawing Name: 21176 - Beacon Phase llFP design A-7720 Design Remote Area Number: Calculation Date: 4/16/2021 Occupancy Classification: Light Hazard Pressure 15.000 Area of Application: NA Coverage per Sprinkler: NA Type of sprinklers calculated: Pendent No. of sprinklers calculated: 6 No. of nozzles calculated: 0 In-rack Demand: N/Agpm at Node Hose Streams: 100.00 at Node N/A 1 Type: Allowance at Source (Safety Margin = 62.537) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 315.42 @86.783 Type of System: Volume of Dry/PreAction/Antifreeze/OtherA N/A Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: 69.813 (LA© M.E.P.CAD, Inc. r,AutoSPRlNK 2020 BETA 06.3.1.0 4/16/202111:32:52AM Page 1 Hydraulic Graph Job Name: Drawing 1 N 1.85 Remote Area Number: Date: 4/16/2021 200— Supply Summary Sheet 180 Node: I -i - - _____ ________ ____________ ______________ ________________ 160— Static Pressure 150.300 15.421321 140 - - 96.00 @ 128.300 120 (fl Co 0. 315.42 with Hose Allowance at Source 215.42 86.783 80- 60- S stem demand curve 40- 20- 0— lift I I I I I I IliCilill 111111111 ItlililCi 111111111 I 11111111 III 111111 1 iiL11 III I 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Flow - gpm A,©M.E.P.CAD, Inc. M AutoSPRINK 2020 BETA v16.3.1.0 4/16/2021 11:32:53AM Page 2 Summary Of Outfiowing Devices I Job Number: 1 Report Description: Light Hazard Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor Pressure (K) Sprinkler 1374 33.04 33.04 11.2 8.700 Sprinkler 1375 33.83 33.04 11.2 9.126 Sprinkler 1376 36.73 33.04 11.2 10.755 Sprinkler 1377 39.63 33.04 11.2 12.519 Sprinkler 1378 36.53 33.04 11.2 10.637 Sprinkler 1379 35.66 33.04 11.2 10.138 c> Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. JAutoSPRlNK 2020 BETA 06.3.1.0 4/16/2021 11:32:55AM Page 4 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 150.300 128.300 1 1696.00 149.321 315.42 86.783 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -2-11 Supply 86.783 215.42 1374 10-0 Sprinkler 8.700 33.04 1375 101-0 Sprinkler 9.126 33.83 1376 101-0 Sprinkler 10.755 36.73 1377 9'- 101/2 Sprinkler 12.519 39.63 1378 9-10% Sprinkler 10.637 36.53 1379 9-10% Sprinkler 10.138 35.66 2 -2-11 86.638 4 -2-11 82.969 5 -2'-11 82.994 6 -2-11 86.522 7 -2'-11 86.552 9 -2-11 86.668 10 -2-11 86.680 11 -2'- 11 86.649 15 -2'-11 86.687 17 -2-11 86.694 21 -2-11 86.646 29 -2-11 86.702 ,© M.E.P.CAD, Inc. MAutoSPRINK 2020 BETA' 4/16/2021 11:32:57AM Page 5 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 68 10-0 76.727 B235 0-6 Gauge 81.427 242 -2-11 82.943 551 931/2 66.591 571 12-3 73.730 846 11-0% 9.504 848 11-0% 9.986 850 11-0% 11.828 852 11-0% 17.094 853 11-0% 13.780 855 11-0% 11.652 .,© M.E.P.CAD, Inc. ]AutoSPRINK 2020 BETA' 4/16/2021 11:32:57AM Page 6 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as naJtiva iII..a Fitting (F oot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ______________ Friction(Pf) 1374 10-0 11.2 33.04 'Ph (See Notes) 2-4 120 8.700 ••••• Route I ••••. Sprinkler, 2E(3'-O), PO(6'-O) 12-0 0.086607 -0.438 846 11-0% 33.04 1.3800 14'-4 1.242 846 ii'-0Y2 11/2 14'-7 120 9.504 0.033036 848 11-0% 33.04 1.6820 14'-7 0.482 848 11'-O% 33.83 11/2 15-1% 120 9.986 Flow (q) from Route 2 0.121772 850 11-0% 66.87 1.6820 15'-l% 1.842 850 11-0% 36.73 1% (See Notes) 9'4 120 11.828 Flow (q) from Route 5 T(9'-11) 91-11 0.273706 852 11-0% 103.60 1.6820 19-3 5.266 852 11'-O% 111.82 11/2 (See Notes) 262 120 17.094 Flow (q) from Route 3 2E(4'-i2E(4'-11'/2),P0(9-li) 19-9% 1.060339 0.750 551 9-3% 215.42 1.6820 45-111/2 48.747 551 9-3% 3 (See Notes) 17651/2 120 66.591 2E(9-5), EE(4'-O%) 22-10 0.042252 -1.282 571 12-3 215.42 3.2600 199'-3% 8.421 571 123 4 (See Notes) 99'8% 120 73.730 2EE(5-3), T(26'-4), 3E(13-2) 76'-41/2 0.011481 0.975 68 10-0 215.42 4.2600 176-1 2.022 68 101-0 4 (See Notes) 8'101/2 120 76.727 ALV(28-0), BV(16-81/2), BOR 44-81/2 0.010847 4.119 B235 0'-6 215.42 4.3100 53-71/2 0.58 1 B235 0-6 6 (See Notes) 3'5 120 81.427 E(17-7) 17-7 0.001634 1.481 242 -2-11 215.42 6.3570 21'-0 0.034 242 -2'-11 6 (See Notes) 1-0 150 82.943 E(11'-5%) 11-5% 0.002508 -0.005 4 -2-11 215.42 5.3490 12-5% 0.031 4 -2'-11 6 (See Notes) 53 140 82.969 LtE(14-2) 14-2 0.001304 1 5 -2-11 215.42 6.2800 19-5% 0.025 © M.E.P.CAD, Inc..M AutoSPRINK 2020 BETA v16.3.1.0 4/16/2021 11:32:58AM Page 7 -Job Name: Drawingl Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as . ncg.tiwa wII.a Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 5 -2-11 6 (See Notes) 9'6 120 82.994 2GV(0-0), 2T(0'-O), BFP(-3.79 2), E(17'-7) 17'-7 0.001634 -0.000 6 -2-11 215.42 6.3570 27-1 3.527 6 -2-11 6 (See Notes) 13 140 86.522 E(22'-l) 22-1 0.001304 7 -2-11 215.42 6.2800 23'-4 0.030 7 -2'-11 6 (See Notes) 1821/2 140 86.552 T(47-31/2) 47'31/ 0.001304 2 -2-11 215.42 6.2800 65-5% 0.085 2 -2-11 10 (See Notes) 34331,, 150 86.638 T(37-6) 37-6 0.000029 11 -2-11 69.48 8.6780 3809h/2 0.011 11 -2-11 8 (See Notes) 43271/2 150 86.649 T(18'-8%) 18-8% 0.000125 -0.003 29 -2-11 69.48 6.4470 451'-31/2 0.056 29 -2-11 8 (See Notes) 651'91/2 150 86.702 0.000125 0.000 1 -2'-11 69.48 6.4470 651'-91/2 0.081 100.00 86.783 Hose Allowance At Source Total(Pt) Route 1 1 315.42 1375 10-0 11.2 33.83 1¼ (See Notes) 2-4 120 9.126 •••••Route2••••• Sprinkler, 2E(3-0), PO(6'-O) 12-0 0.090519 -0.438 848 110h/2 33.83 1.3800 14-4 1.298 9.986 Total(Pt) Route 2 1379 9'-10Y2 11.2 35.66 11/4 (See Notes) 2-5% 120 10.138 'Route3' Sprinkler, 2E(3-0), P0(6-0) 12-0 0.099771 -0.495 857 11-0% 35.66 1.3800 14-5% 1.444 857 11-0% 14'10 120 11.087 0.038058 855 1101/2 35.66 1.6820 14-10 0.565 &@ M.E.P.CAD, Inc. M AutoSPRINK 2020 BETA v16.3.1.0 4/16/2021 11:32:58AM Page 8 'Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID & Devices Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as 2 flflg2tisla lV211i0 Fitting (Fo ot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) ______________ Friction(Pf) 855 11'-O% 36.53 VI 15-2 120 11.652 Flow (q) from Route 4 0.140299 853 11-0% 72.19 1.6820 15-2 2.128 853 11-0% 39.63 V/2 (See Notes) 071/2 120 13.780 Flow (q) from Route 6 T(9'- 11 91-11 0.315227 852 1i01/2 Ll 111.82 1.6820 10-6 3.315 17.094 Total(Pt) Route 3 1378 9101/2 11.2 36.53 11/4 (See Notes) 2-5% 120 10.637 ''•' Route 4''''' Sprinkler, 2E(3'-O), P0(6-0) 12-0 0.104304 -0.495 855 1101/2 36.53 1.3800 14-51/2 1.510 11.652 Total(Pt) Route 4 1376 10-0 11.2 36.73 (See Notes) 2-4 120 10.755 " Route 5"•'• Sprinkler, 2E(3'-O), P0(6-0) 12-0 0.105370 -0.438 850 11-0% 36.73 1.3800 14-4 1.511 11.828 Total(Pt) Route 5 1377 9'- 101/2 11.2 39.63 1¼ (See Notes) 2-51/2 120 12.519 '•'•Route6''''. Sprinkler, 2E(3-0), PO(6'-O) 12'-0 0.121270 -0.495 853 11-0% 39.63 1.3800 14-5% 1.755 13.780 Total(Pt) Route 6 9 -2'-11 145.93 10 97'-91/2 150 86.668 ''''' Route 7''''' Flow (q) from Route 8 0.000116 10 -2-11 145.93 8.6780 97'-91/2 0.011 10 -2-11 10 (See Notes) 54'i 150 86.680 EE(8'-3) 8-3 0.000116 15 -2-11 145.93 8.6780 62'-4 0.007 15 -2-11 10 (See Notes) 22'9% 150 86.687 T(37'-6) 37-6 0.000116 17 -2-11 145.93 8.6780 60-3% 0.007 17 -2-11 8 (See Notes) 163'61/2 150 86.694 5, T(18-8%) 18-8% 0.000491 -2'-11 L-j 145.93 6.4470 182-3 0.090 86.783 Total(Pt) Route 7 © M.E.P.CAD, Inc. AutoSPRINK 2020 BETA 06.3.1.0 4/16/2021 11:32:58AM Page 9 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) FittinglDevice (Equivalent Fitting (F oot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit (psi) when applicable, are added Total (Foot) (Q) (Foot) (Foot) Friction(Pf) directly to (Pt) and shown as flQgtiSrn ______ __________ 2 -2-11 69.48 10 85-1 150 86.638 Route 8' Flow (q) from Route I -0.002 21 -2-11 145.93 8.6780 0.000116 85'-1 0.010 21 -2-11 10 (See 1965 150 86.646 8-3 -0.001 Notes) 9 -2-11 145.93 8.6780 0.000116 EE(8'-3) 204-8 0.024 86.668 Total(Pt) Route 8 &@ M.E.P.CAD, Inc. WjAutoSPRINK 2020 BETA v16.3. 1.0 4/16/2021 11:32:58AM Page 10 Job Name: Drawingi Remote Area Number: Date: 4/16/2021 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) • IC Value Multiplier • Actual Inside Diameter 4.87 = Factor Value Of C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter) Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111h° Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. Ji.lAutoSPRINK2020 BETA v16.3. 1.0 4/16/2021 11:32:58AM Page 11 ITA14 FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPRESSION MATERIAL SUBMITTAL BEACON BLDG. A 7720 EL CAMINO REAL CARLSBAD, CA. 92009 CONTRACT NO. 21176 1341 Distribution Way, Suite 14 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437-- fax www.titanfpinccom Page A CIITA14 FIRE PROTECTION Fire Protection Contractor - License #989280 TABLE OF CONTENTS SPRINKLERS OVERHEAD PIPE AND FITTINGS HANGERS AND SEISMIC VALVES OTHER 1341 Distribution Way, Suite 14 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page Page 1 of % KjWfij ® MICROFAST® QUICK l.l:II[1uqy RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast5 Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *cuLus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57 =A, 155°/68 = B, 175/79 = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 2 of 4 N H(11G® MICROFAST® QUICK 11i1:II[i.,yy RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfase Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color U 0 0 Classification Temperature Rating' Ceiling Temperature' Ordinary 135 ¶ (57 C) 100 °F (38 C) Orange Ordinary 155 °F (68 °C) 100 F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 C) Yellow Intermediate 200 ¶ (93 °C) 150 °F (65 C) Green High 286 ¶ (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap— Wrench Flat - Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_052114 18.10.11 Rev 17.1.P65 Page 3 of 4 MICROFAST® QUICK 1( N 11 NG l:IlI.qiuIyy RESPONSE UPRIGHT SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY Microfaste Quick Response ++ F,r'sh 1 AIX4 Escutcheon .f apphcabe) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 Number1 NPT BSP U.S. metric2 Inches mm cULus VdS LPCB NYC8 CE 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 -- -- - See footnote 7.1 -- 06661B VK300 1/2" 15mm 5.6 80.6 2-3/16 56 Al, B2 -- -- See footnote 7.! -- Approved Temperature Ratings A- 135°F (57 °C), 155°F (68 °C) 175°F (79 °C) 200°F (93 °C) and Approved Finishes 286 °F (141°C) 1 - Brass, Chrome, White Polyester56, and Black Polyester56 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast6 Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Page 4 of 4 EAV1. MICROFAST®QUICK l:Il[1u.7M RESPONSE UPRIGHT I I I SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) I Temperature KEY - Microfaste Quick Response tx 4 Escutcheon (:1 applicable) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN (Refer also to Design Criteria below.) NPT F BSP U.S. metric2 Inches mm 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 06661B VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175 °F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 White Polyester5, and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Aoeroval Reauirements: The Microfaste Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 1 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT NIIQ NG® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPCB Approved: Certificate number 096e/12 WARNING: Cancer and Reproductive Harm- Zt CE CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249 © CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMethc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 2 of 7 MIRAGE® STANDARD AND l.l:II[iu.JM QR CONCEALED PENDENT SPRINKLER VK462 AND HP N4 L SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C1I000 or Stainless Steel UNS-530400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 OF (68 "C) = B, 175 OF (79 °C) = D, 200 OF (93 °C) = E For example, sprinkler VK463 with a 155 OF (68 °C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 OF (57 °C) UL (139 OF (59 "C) FM and LPCB) = A, 165 OF (74 "C) = C For example, cover 13504 with a Polished Chrome finish and a 165 OF (74 °C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 OF (57 "C) UL (139 OF (59 "C) FM and LPCB) = A, 165 OF (74 °C) = C For example, cover 21876 with a 165 OF (74 "C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 OF (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a 1/2' ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 3 of 7 N MIRAGE® STANDARD AND II(ING® l:II[ru'7'iv.. QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE l AND FINISHES tcli Sprinkler ' Sprinkler Maxi Maximum Nominal Ambient Temperature Rating of Cover Cover Plate Large Cover Square Cover Temperature Temperature Ceiling Assembly (Required) Base Part Plate Base Part Plate Base Part Bulb Color Classification Rating' Temperature2 Number3 Number'Number3 Ordinary 155 °F (68° C) 100 °F (38 °C) 135°F (57 °C)cULus 13504 or 218761 13642 or 21875 5 15394 Red 139 °F (59 °C) FM and LPCB Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 °C) 13504 or 21876 13642 or 21875 15394 1 Yellow Intermediate 200 °F (93° C) 150 °F (65° C) 165 °F (74 °C) 113504 or 21876 13642 or 2187511 15394 1 Green Cover Plate Finishes5: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings4: ENT Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. \\ N!KIk I All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers I Figure 2: Square Cover Assembly 15394 Form No. F_103005 18.10.11 Rev 18.2.P65 Page 4 of 7 if TECHNICAL DATA I lilt. At. . 14. The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) SprinklerTemperature Rating Rating - I Mirage4' Concealed Pendent Sprinklers VK462 and VK463 L AWli- Cover Plate Finish KEY - I Sprinkler Thread Nominal Maximum Listings and Approvals4 SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.' Pressure I Inch mm U.S. metric? cULus' I NYC I VdS7 I LPCB CE 12 Standard Response Applications 13503A VK462 1/2" -- 5.6 80.6 175 psi (12 bar) - -- AY1,CZ1 AY1,BZ1 AY1,CZ18 AY3 -- 19785A VK462 1/2" -- 5.6 80.6 175 psi (12 bar) -- -- - -- -- -- AY2, CZ2 21356A VK462 -- 15 5.6 80.6 175 psi (12 bar) -- -- - -- -- - AY2, CZ2 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AV1, BX1 - - -- AY3 -- AS3, BT3 AV1, BX1, 13503JN1' VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1' - - -- -- -- AS3, BT3 13667A VK463 1/2" 15 5.6 80.6 250 psi (17.2 bar)3 I AV1, BX1 I AV1, BX16 -- -- -- -- -- Cover Plate Assembly Temperature Ratings19 Sprinkler Temperature S - 135 °F (57 °C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes10 Ratings I - 165 ¶ (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique A- 155 'F (68 °C) °F 'C) V - 135 (57 cULus Listed cover 13504, 13642 (large diameter), or 15394 (square cover plate) Brass, Brushed Brass, Brushed Copper, Painted White, B - 175 °F (79 °C) and 200 °F x - 165 °F (74 °C) cover 13504, or 13642 (large diameter) Painted Ivory, or Painted Black (93 C) Y - 135 °F (57 °C) cover 13504 LPCB Approved as 139 F 2 - Brass C - 200 °F (93 °C) (59 C) 3 - Stainless Steel Z - 165 °F (74 °C) cover 13504 Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A11:2001 + A2:2004 + A3:2006, Certificate G4080021. 'CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. ID Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. I cULus Listed as corrosion resistant. 12 MED Certified, Standard 12259-1, EC-certificate 0832-MED-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 5 of 7 MIRAGE® STANDARD AND N4"IQWJ QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart I) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS ADoroval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN 12845. These sprinklers can only be installed in LH and OH occupan- cies, except in 0H4. NOTES: Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F103005 18.10.11 Rev 18.2.P65 Page 6o17 MIRAGE® STANDARD AND QR CONCEALED PENDENT A Im IQ W*j® SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com A —SpnnMerTemperatureRathg Approval Chart 2 (FM) -- - -- Cover Plate Temperature Rating Mirage"; Standard Response Concealed Pendent Sprinkler VK462 AWli- Cover Plate FnIsh KEY Sprinkler Base I NPT Thread Size Nominal K-Factor Maximum FM Approvals3 Part No.' SIN I I i I I Water Working I (Refer also to Design Criteria below.) I Inch I mm U.S. I me1z1c2 I Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1,AY2, BZ2 Cover Plate Assembly Temperature Ratings14 Cover Plate Assembly Finishes' Y - 139 °F (59 "C) cover 21875 or 21876 Sprinkler Temperature Ratings z - 165 °F (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A - 155 "F (68 °C) W - 139 °F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B - 175°F (79 °C) and 200 °F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 °F (74 "C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 2-1/4" (57 mm) diameter opening required in the ceiling. Page 7 of 7 n MIRAGE® STANDARD AND QRCONCEALED PENDENT SPRINKLER VK462AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler and Adapter Assembly Protective cap Sprinkler Wrench removed I Part No. 14047WB** Use wrench 14047WB** ft . .-. Step F Carefully slide the wrench sideways around the deflector and pins Step 2: t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 112" ratchet is required (Not available from Viking) Sprinkler frame arms Sprinkler wrench fla 1/2" (15 mm) NPT 2-9/16" (65 mm) Maximum / 2-1/16" (52 mm) Minimum tzz EE '4! 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_i 03005 18.10.11 Rev 18.2.P65 Replaces Form No. F_i 03005 Rev 18.2 (Added P65 Warning.) Page 1 of 6 NHle iFi G ® MICROFASTO QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and tem- perature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 S. LPCB Approved: Certificate 096e/06 WARNING: Cancer and Reproductive Harm- - www.P65Wamings.ca.gov CE: Standard EN 12259-1 ,Declaration of Performance DOP_Sprinklers_LPCB_5-2-19, DOP_VK302ENT_29-1-20 & DOP_VK302- 57C_30-9-20 China Approval: Approved according to China GB standard MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart I and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated SDrinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Form No. F033314 20.07.14 Rev 20.1 Replaces Form No. F_033314 Rev 19.3 (Added ENT to CE Approval.) Page 2 of 6 k EKING® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 OF (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A %" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F033314 20.07.14 Rev 20.1 Page 3of6 DffI. ® MICROFAST®QUICK %Bt RESPONSE PENDENT '1 SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal I Maximum Ambient I Bulb Color U Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 °F (57 °C) 100 OF (38 °C) Orange Ordinary 155 OF (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. 4* Sprinkler wrench 13655W/B** for recessed pendent sprinklers **A I/2 ratchet is required - (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 20.07.14 Rev 20.1 Page 4 of 6 Mk 0 H(ING® MICROFAST® QUICK l.I:II[iuIJf RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY The Viking Microfasr Quick Response Pendent Sprinkler VK302 AIX 4— Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Base Thread Size Nominal Overall Listings and Approvals3 Sprinkler K-Factor Length Criteria.) Style (Refer also to Design Criteria.) Part • — Number' NPTFBSP U.S. metric' Inches mm cULus4 VdS LPCB CE7 MED8 China Approval 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 AlZ, B1Y, D2, C2X Al A1Z, B1Y D1Z,C1Y,D2, Dl AZ, BY 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 D3 -- -- -- -- D3 06662B VK302 Pendent 1/2" 15m 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X -- -- -- -- 18021 VK302 Pendentl 1/2" 15mm 5.6 1 80,6 2-1/4 58 A1Z,B1Y Al I A1Z,B1Y I D1Z,C1Y,D2 Dl -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 OF (57 °C), 155 OF (68 °C), 175 OF 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 OF (93 °C), 286 OF (141 °C) Polyester56, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF ter 6 Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® (79 °C), and 200°F (93 °C) 2- ENT' Model E-1, E-2, or E-3 Recessed Escutcheon C - 155 OF (68 °C), 175 OF (79 °C), and 3 - Chrome Z - Standard surface-mounted escutcheon 200 OF (93 °C) D -155 OF (68 °C), 175 OF (79 °C), 200°F (93 °C), 286°F (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. "Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE: Standard EN 12259-1 Declaration of Performance DOP_Sprinklers_LPCB_5-2-19, DOP_VK302ENT_29-1-20 & DOP_VK302-57C_30-9-20. MED Certified, Standard EN 12259-1, EC-0832-MED-1003. 9Approved according to China GB Standard. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast5 Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 20.07.14 Rev 20.1 Page 5 of 6 MICROFAST®QUICK II% . RESPONSE PENDENT I I SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY I I The Viking Microfast® Quick Response Fnsh AIX+- Escutcheon (if applicable) Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP - - Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2' 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 213546 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 C3 06662B VK302 I Pendent 1/2" 15 mm I 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings A - 135 °F (57 "C), 155 "F (68 °C), 175 "F (79 °C), 200 °F Approved Escutcheons (93 °C), 286 °F (141 °C) Approved Finishes X - Standard surface-mounted escutcheon or the B - 135 °F (57 °C), 155 F (68 CC), 175 °F (79 "C), and - Brass, Chrome, White Polyester4, Viking Micromatic® Model E-1 Recessed Escutcheon 200 °F (93 °C) and Black Polyester4 Y - Standard surface-mounted escutcheon or recessed C - 155 °F (68 °C), 175 °F (79 CC), 200 "F (93 °C), 286 2 - ENT' with the Viking Micromatic® Model E-1 or E-2 "F (141 °C) 3 - Chrome Recessed Escutcheon D - 155 °F (68 °C), 175 ¶ (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. 6 Approved according to China GB Standard. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM ADDroval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation quidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 20.07.14 Rev 20.1 Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum I p (51 mm) Max. 1-1/8" (29 mm) Mm. 1-1/8" (29 mm) Mm. Page 6 of 6 ® MICROFAST®QUICK RESPONSE PENDENT '1 'J SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com - Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT 72-1/4" X= - . (5;j ) 1-3/4" (45 mm) Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon (54 mm) I ii + 1-3/4" (45 mm) Max. Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 20.07.14 Rev 20.1 Replaces Form No. F_033314 Rev 19.3 (Added ENT to CE Approval.) Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK534 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The extra-large orifice produces the flows required to meet Light and Ordinary Hazard density re- quirements at lower pressures than standard orifice or large orifice sprinklers. The glass bulb operating element and special deflector characteristics meet the challenges of quick response extended coverage standards. Pendent Sprinkler VK534 is cULus Listed as standard and quick response. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, ENT coating has been investigated for installation in corrosive atmospheres. See Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV Refer to Approval Chart 1 and Design Criteria cULus Listing requirements. 3. TECHNICAL DATA 1— NOTE: As of May 2018 all logos have been re- moved from the wrench boss. WARNING: Cancer and Reproductive Harm- Specifications: • www.P65Warningscagov Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4" (20 mm) NPT Nominal K-Factor: 11.2 U.S. (161.3 metrict) t Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: 2-3/8" (61 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinkler: Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking EC/QREC Pendent Sprinkler VK534 by first adding the appropriate suffix for the sprinkler finish and then the appro- priate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C)=A, 155°F (68 °C)= B, 175°F (79 °C) = D, 200°F (93 °C) = E, and 286°F (141 °C) = G For example, sprinkler VK534 with a Brass finish and a 155 OF (68 °C) temperature rating = Part No. 08340AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website) Sprinkler Wrenches: Standard Wrench: Part No. 05118CW/B (available since 1981) Wrench for recessed pendent sprinkler: Part No. 11663W/B** (available since 2001) **A 1/2" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F051393 19.02.21 Rev 19.1 Replaces Form F_051393 Rev 18.2.P65 (Removed F-i Escutcheon.) Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking EC/QREC Pendent Sprinkler VK534 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_051393 19.02.21 Rev 19.1 Page 3of6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com visit me ViKifl9 weosite ror me latest eaiuon or mis iecnnucai oats page www.viKinggroupinc.com Sprinkler Temperature Sprinkler Nominal Maximum Ambient u o Bulb Color Classification Temperature Rating' Ceiling Temperature 2 Ordinary 135 °F (57 °C) 100 °F (38 C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester3, Black Polyester3, and ENT Corrosion-Resistant Coatings4: ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For ENT sprinklers, all exposed surfaces and the waterway are coated, but note that the spring is exposed. Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. Pendent Sprinkler Sprinkler wrench 13577W/B** must be used for installing wax coated sprinklers. ** A 1/2" ratchet is required (not available from Viking) Step 2: Carefully press the wrench upward and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 11663W/B for Recessed Pendent Sprinkler VK534 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart I (UL) 1 KEY I SRIQR EC Pendent Sprinkler VK534 Sprinkler Base NPT Thread Size I I Nominal K-Factor Maximum Water Overall Length Part Number' SIN Working Pressure I Inches I mm I U.S. I metric' Inches mm 08340 Pendent VK534 3/4 20 11.2 1 161.3 175 psi (12 Bar) 2-5/16 59 Minimum Water Supply Requirements' Listings and Approvals3 Max. Sprinkler Maximum (Refer also to UL Design Spacing Area per Criteria) (Lx W') Sprinkler Light Hazard Ordinary Hazard Group I Ordinary Hazard Group Il Flow! Pressure Flow! Pressure Flow! Pressure cULus' Standard Response 16 ft. x 16 ft. (4.9 256 ft2 (23.8 -- 38 gpm @ 11.5 psi 51 gpm @20.7 psi C1W, D1Y, D2Z, C2W m x4.9 m) m2) (143.9 Umin @ 79 Bar) (193.1 Umin @1.43 Bar) 18 ft. x 18 ft. (5.5 324 ft2 (30.1 49 gpm @ 19.1 psi 65 gpm @ 33.7 psi C1W, D1Y, D2Z, C2W m 5.5 m) m2) -- (185.5 L/min @ 1.32 Bar) (246.1 L/min @2.32 Bar) 20 ft. x 20 ft. (6.1 400 ft2 (37.2 -- 60 gpm @28.7 psi 80 gpm @ 51.0 psi 502.8 C1W, D1Y, D2Z, C2W m x 6.1 m) m2) (227.1 Umin @ 1.98 Bar) Umin @ 3.52 Bar) Quick Response 12 ft. x 12 ft. (3.7 144 ft2 -- 30 gpm @7.2 psi 39 gpm @ 12.1 psi ElY, E2Z m x 3.7 m) (13.4 m2) (113.6 Umin @ .50 Bar) (147.7 Umin @ .84 Bar) 14 ft. x 14 ft. (4.3 196 ft2 30 gpm @7.2 psi 39 gpm @ 12.1 psi ElY, E2Z m x 4.3 m) (18.2 m2) -- (113.6 L/min @ .50 Bar) (147.7 Umin @ .84 Bar) 16 ft. x 16 ft. (4.9 256 ft2 (23.8 30 gpm @ 7.2 psi -- B1Y, F2Z m x 4.9 m) m2) (113.6 Umin @ .50 Bar) -- 18 ft. x 18 ft. (5.5 324 ft2 (30.1 33 gpm @8.7 psi (124.9 U -- -- B1Y, F2Z m x 5.5 m) m2) min @ .60 Bar) 20 ft. x 20 ft. (6.1 400 ft2 (37.2 40 gpm @ 12.8 psi (151.4 -- -- A1Y, G2Z m x 6.1 m) m2) Umin @ .88 Bar) Approved Temperature Ratings A- 135 "F(57 *C) and 175 "F(79 "C) Approved Escutcheons B - 135 "F (57 "C), 155 "F (68 "C), and 175 ¶ (79 "C) Approved Finishes W - Standard surface-mounted escutcheons only C - 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), and 1 - Brass, Chrome, White Polyester, and Black Y - Standard surface-mounted escutcheons or the Microfasta 286 "F (141 "C) Model F-i Adjustable Escutcheon, or recessed with the D - 155 "F (68 "C), 175 "F (79'C), and 200 "F (93 "C) Polyester Micromatic Model E-i, E-2, or E-3 Recessed Escutcheon E - 155 "F (68 "C) 2 - ENT Z - Standard surface-mounted escutcheons or the Micromatic F - 155 "F (68 "C), and 175 "F (79 "C) Model E-1 Recessed Escutcheon. G -175 "F(79 "C) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows listings and approvals available at time of printing. Check with the manufacturer for any additional approvals. cULus Listed for use in the U.S. and Canada. To determine "Minimum Water Supply Requirement" for areas of coverage where length and width of actual sprinkler spacing are not equal, select the "Maximum Sprinkler Spacing" from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 10-6" x 13-0" sprinkler spacing, provide the "Minimum Water Supply Requirement" listed in the chart for 14-0" x 14-0" spacing. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" in the appropriate hazard group for the next larger area listed. The distance from sprinklers to walls shall not exceed one-half the "Maximum Sprinkler Spacing" listed for the "Minimum Water Supply Requirement" used. 6 cULus Listed as corrosion-resistant. Form No. F_051393 19.02.21 Rev 19.1 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: EC-ELO Pendent Sprinkler VK534 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers as indicated below: The minimum water supplies and maximum areas of coverage shown in Approval Chart 1 are designed to provide the following design densities: 0.10 gpm/ft2 (4.1 mm/mm) for Light Hazard densities; 0.15 gpm/ft2 (6.1 mm/mm) for Ordinary-Hazard Group I densities; 0.2 gpm/ft.2 (8.1 mm/mm) for Ordinary-Hazard Group II densities. The sprinkler installation rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. Viking EC-ELO Pendent Sprinklers are cULus Listed for use in unobstructed construction, and noncombustible obstructed construction consisting of solid steel and/or concrete beams as defined in the latest edition of NFPA 13. Ceiling slope not to exceed 2112 (9.5"). Also. Viking ECOH-ELO Pendent Sprinkler VK534 is specifically cULus Listed for Ordinary Hazard Occupancies: For non-combustible obstructed construction within trusses or bar joists having non-combustible web members greater than 1" (25.4 mm) when applying the 4 times obstruction criteria rule as defined in NFPA 13 under "Obstructions to Sprinkler Discharge Pattern Development". For installation under concrete tees when installed as follows: The stems of the concrete tee construction must be spaced between 3 ft (0.9 m) and 7 ft-6 in (2.3 m) on center. The depth of the concrete tees must not exceed 30 in (762 mm). The maximum permitted concrete tee length is 32 ft (9.8 m). However, where the concrete tee length exceeds 32 It (9.8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 ft (9.8 m). The sprinkler deflector is to be located in a horizontal plane at or above 1" (25.4 mm) below the bottom of the concrete tee stems. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_051393 19.02.21 Rev 19.1 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 3/4" (20 mm) NPT - - J Ceiling Opening Size: L 2-5/16" (59 mm) minimum 1 2-1/2" (64 mm) maximum 2-3/8" (60 mm) 1-1/2" (38 mm) L U L 1-3/4" (45 mm) Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2.1/2" (64 mm) maximum 2-1/8"--m mm) ~r(54 -. n1i7! 1-3/4" I] (45 mm) Max. V 2" (29 mm) (51 mm) L. Mm. Max. ; (54 mm) 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_051393 19.02.21 Rev 19.1 Replaces Form F_051393 Rev 18.2.P65 (Removed F-i Escutcheon.) FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Schedule 10 Pipe maarPw@wsv 11 IF I:IF-I 1 1.315 1.097 1.41 lbs/ft 91 11/4 1.660 1.442 1.81 lbs/ft 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe iiGaliho M IF WVM ii 1 1.315 1.049 1.68 lbs/ft 70 11/4 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 2112 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.260 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's - instructions for the specific fitting used. Chesterfield, MO 63017 contact your salesperson c®tis44 1819 Clarkson Road For additional information, (800) 325-4467 today at (800) 325-4467 or 6 LISTED BULL. MOOSE TUBE C M'iJV FAX: (636) 537-2645 (636) 537-2600 in the USA, www.bullmoosetube.com or from Canada ACflPRRQcompany e-mail: sa1esbu!1moosetube.com call (800) 882666 <i > ______ APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 ALTERNATE STYLES Victaulic offers a broad line of fittings in sizes through 6071500mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to Section 14.04 for fittings available for plain end applications). Fittings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish available as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange® adapters, check disc clearance dimensions with I.D. dimension of fitting. Note: The following Victaulic fittings are VdS approved: No.1090" Elbow, No.11 45" Elbow, No.20 Tee and No.60 Cap. Note: The following Victaulic fittings are LPCB approved: No.10 90" Elbow, No.11 45" Elbow, No. 12 221/2" Elbow, No.13 111/4" Elbow, No.30 45" Lateral, No.30-R Reducing Lateral, No. 100 Long Radius Elbow, No. 110 Long Radius Elbow, No.20 Tee, No.35 Cross, No.60 Cap, No.25 Reducing Tee, No.33 True Wye, No.50 Concentric Reducer, No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. NO. 20 TEE NO. 10 ELBOW Advanced Groove System - For 14— 60/350 - 1500mm piping systems, Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS fitting details. Stainless Steel - Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 available as an option) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum - Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 - 8/25 — 200 mm. Refer to Section 21.03 or contact Victaulic for details. Fabricated Steel - A full range of fabricated segemtnally welded steel or full flow grooved end fittings are available refer to section 07.04. Fabricated Steel with AGS Vic-Rings - A full range of full flow fabricated fittings with Vic-Rings are also available. AGS - ADVANCED GROOVE SYSTEM Extra Heavy EndSeal® "ES" Fittings - EndSeal fittings are available in 2— 12/50 — 300 mm for use with "ES" grooved pipe and HP-70ES EndSeal couplings. "ES" fittings are painted black for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fittings" when ordering. See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MRL) - For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. Note: Fittings are available with a variety of coatings upon request such as hot dip galvanized, epoxy, glass lined and others. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Approved Date www.victaulic.com vlcTAuuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_R \%taukcr 07.011 CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Or: Segmentally welded steel as shown under nipples Nipples: (adapter, swaged & hose) 3/4 - 4/20 - 100 mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type F 5-6/125 - 150mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type E or 5, Gr. B 8— 12/200 - 300mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53, Type E or 5, Gr. B Flanged Adapter Nipples: (Nipple - see above) Class 125 Flange: Cast iron conforming to ANSI B-16.1 Class 150 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Class 300 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Fitting Coatings: Orange enamel Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard - see product specifications. Flanged Adapter Nipple Coating: None (Unfinished) Optional: Orange enamel, hot dip galvanized and others. www.victaulic.com ictaulid vlcTAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. Q 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.012 REVR CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221h elbow is one-nail me resistance or a 43 eioow. vaiues 01 mm-sizes can oe I 1 1.315 1.7 0.8 4.2 1.7 25 33.7 2.375 0,5 3.5 - 2.5 0.2 1.8 - 1.1 1.3 8.5 0.5 3.5 2 50 60.3 -I- 3.000 , 1.1 -- 4.3 0.8 - s- - 0.5 - 2.1 0.3 - - 2.6 -4---- - ---- 10.8 --4- -'-- 1.1 4.3 761 mm 76.1 3.500 1.3 5.0 3.8 0.7 2.6 1.6 3.3 13.0 1.3 5.0 3 80 88.9 - - - 1 - 4.250 1.5 - 6.4 1.2 - 0.8 3.2 ---4----- 0.5 ------I- ' 4.0 - - 15.3 - - 1.5 6.4 _____ mm - 108.0 ' 4.500 2.0 68 - I 5.0 I 0.9 3.4 - 2.1 --4.. 4.7 16.0 + -- 2.0 6.8 4 100 114.3 ' - _------+ _ 5.250 2.1 ---4- 8.1 1.5 +-------4--.--.- 1.0 4.1 ' 0.6 ---4.-'---' 4.9 20.0 -+ - 2.1 - 8.1 mm - 133.0 5.500 2.5 8.5 - 1.2 4.2 - 6.2 21.0 2.5 8.5 7 mm 139.7 i ------+--.-. 5.563 2.6 8.5 - ' . 1.3- 4.2 - I'--+-''-- 6,4 21.0 .........-.4.--.-. 2.6 8.5 5 125 141.3 - -- - - 6.250 ' 2.6 9.4 - -.4-.- I 1.3 4.9 - '--+--'-----f- , - . 6.4 -' 25.0 2.6 9.6 ___ 159.0 mm 159.0 6.500 2.9 9.6 - ' 1.5 5.0 - - '-4--..- 7.6 25.0 4-----'- 2.9 10.0 165.1 mm 165.1 6.625 2.9 10.0 - ------- 7.5 - 1.5 ----4. - -. 5.0 3.0 7.6 ' 25.0 3.0 10.0 6 150 168.3 --1-'- 8.625 3.0 13.0 - ----4-- 2.3 -----4--- 9.8 1.5 6.5 - -.4-- 0.9 - 4.0 , 7.6 -4- '- - - ' 33.0 ---4- - - ' 3.0 - - - 13.0 8 200 219.1 - I 10.750 40 - 17.0 3.0 -4-' 12.0 2.0 8.3 --'---+---- 1.2 . 5.0 10.1 - ''- 41.0 , -4---- 4.0 - 17.0 10 250 273.0 ------4- - 5.2 3.7 -4.---, ,.-4----------1- 2.5 1.5 --- - 12.5 - ... - - - -. --I- 5.2 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 300 323.9 ------4------ 14.000 6.1 24,5 § 4.4 -- ---4.----.- 15.8 , 3.0 18.55 1.8 -4- -- 11.0 15.2 -4----- .- 70.0 ' 4-..- 6.1 23.0 14 350 355.6 - -4- - 16.000 7.5 - 28.08 4.8 - - - -----4- 18.0 5.6 - - -- 21.08 3.4 -4----- - ' 13.0 21.3 -4--- 80.0 7.0 27.0 _____ 16 400 406.4 8.5 5.5 ' 6.4 4.0 24.4 ' 8.2 ______ - ------ --4--------1- 18.000 31.08 -' .,- 20.0 -,.- 23.58 4-- 14.0 - 90.0 -4----. 30.0 18 450 457.0 -4- - 20.000 9.5 34.08 -----4- 6.1 .- 22.5 , 7.2 25.55 4.3 - 16.0 ' 27,4 - 100.0 . 9.1 33.0 20 800 508.0 24.000 -4----- 10.4 42.08 ' 6.9 ' 1-- 27.0 7.8 -- ----+ 29.5 § - 4.9 . -. -.- 19.0 I 30.5 t .' . 120.0 ' - - - 10.1 -- 40.0 24 600 610.0 , 12.8 8.2 9.0 5.8 36.6 12.2 Fittings available up to 6011500 mm. Contact Victaulic for details. # Contact Victaulic for details. # For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Fitting flow data for 14-247350-600 mm size No, 10 and No. 11 Elbows is based on fittings for Style 07 and 77 couplings. For flow data on AGS fittings (No. W10 and No. W11 Elbows), refer to submittal 20.05. Note: All fittings are ductile iron unless otherwise noted with an 'sw" or "s'. S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVR \4taulicr 07.013 FLOW DATA (Frictional Resistance) CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee CtoE1 - CtoE NO. 25 Grooved Branch T NO. 29T Threaded Branch ft....._. C to to NO. 25 NO. 29T 4- c to E - LI; J- j C to NO. 25-SW C to L A C o NO. 291-SW T______ 1 1 '/4 2,25tw 2.24 sw 1.0 25 20 57 2.75 sw 57 2.75 sw 0.5 1.3 1¼ 11/, 1 32 32 25 70 70 0.6 1½ 1 1/2 3/4 2.75 sw 2.75 sw -4- 1.5 40 X X 40 20 70 70 0.7 2.75 sw I 2.755w . 1.5 1 25 70 I 70 - -- . I_-- 0.7 1¼ 2.75 sw 2.75 sw 1.7 32 70 70 3.25 0.8 2.5 2 2 3/4 3.25 50 50 20 83 83 1.1 - -- - 1 3.25 3,25 2.7 25 83 83._ 12 - ._ 11/4 3.25 sw1 3.25 sw 1.8 32 83 83 0.8 3.755w 3.75sw I 39 21/2 21/2 3/~ x x 65 65 20 95 95 1.8 - - - - - 4------ 1- - 1 3.75 3.75 sw 3.8 25 95 95 1.7 - -. 1 ¼ 3.75 sw . 3.755w 4.2 32 95 'I 95 1.7 11/2 3.75 3.75 3.9 40 .95 95 ± - - 2 3.75 3.755w 4.5 50 95 95 I sw 4.25 sw + 2.0 - 5.7 3 3 3/4 4.25 80 >< 80 20 - - 108 108 2.6 - 1 4.25 4.25 6.1 25 108 108 IS 1-- - - - -- 1¼ 4.25 sw 4.25 sw 8.0 32 108 108 3.6 - -.. -----. - 4 -.-- -_- - 1½ 4.25 4.25 sw 6.5 40 108 108 2.9 2 4.25 4.25 sw 6.2 50 108 108 2.8 21h 4.25 425sw 6.4 65 108 - 5.00sw 108 - 5.005w -.- - 2.9 8.0 4 4 ~ 100 100 20 --------.4---- 127 . 127 3.6 1 5.00 5.00 7.8 25 127 127 3.5 T ~~ 11 IN ~ ______ 1 4 4 x x 11/4 5.00 sw I 5,005w 9.6 100 100 32 127 127 44 , 1 1/2 5.00 ' 5.00 10.2 40 127 127 ----4- 4.6 2 5.00 5.00 11.2 50 127 127 5.1 + 21/2 5.00 . 5.00 11.4 65 127 127 5.__ -. . -- 3 5.00 5.00 11.6 80 127 5.50sw 127 "---4---- 5.50sw 5.3 14.0 5 5 1 125 125 140 - 140 6,4 - 1½ 5.50 sw 5.50sw 14.3 40 140 140 -+ 6.5 2 5.505w ' 5.50sw 14.5 50 140 140 ' 6.6 21/2 5.50 5.50sw 15.2 65 140 140 6.9 3 5.50 5.505w 16.6 80 140 140 7.5 4 5.50 5.50sw 16.7 100 140 6.50sw ' 140 6.50sw -.-_---- 7.6 23.0 6 6 1 x 150 150 > 25 165 165 . 10.4 -- 1½ 6.50sw 6.505w 24.0 40 165 165 10.9 6.50 6.50 21.6 2 50 165 --.-.±-- ' - 165 --- 9.8 + 21/2 6.50 1 6.50 21.4 65 165 165 11.7 14-60' AOS'For AGS fitting information, see publication 20.0 350-1500mm + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s 5= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. www.vjctauljc.com \,4tauIic° viciuuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 vIcTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01_10 . REV_R CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee bCtoE CtoE.1 NO. 25 Grooved Branch NO. 291 Threaded Branch to to NO. 25 NO. 29T . c tot - to NO. 25-SW C to E to NO. 291-SW 6 6 X 3 6.50 1 6.50 26.5 150 150 80 165 165 12.0 4 6.50 6.50 25.0 100 165 165 11.3 5 6.50 6.50 1 23.2 125 165 165 10.5 61/2 61/2 3 6.50 1 6.50 sw ' .... 165.1 165.1 X 80 - 165 165 j - 10.9 - 4 6.50 6.50 sw 25.0 100 165 7.75 sw 165 7.75 sw 11.3 -- 33.0 8 8 1 ½ 200 X 200 40 197 197 15.0 2 7.755w 7.755w 33.5 50 197 , - 197 I 15.2 7.75 sw 7.75 sw 39.0 21/2 65 197 ------------------ 197 17.7 3 7.755w 7.75 sw 33.6 80 197 197 15.2 4 7.75 7.75 41.8 100 197 197 19.0 'I 5 7.75 Sw 7.75sw 34.0 125 197 4 - 1974 - 6 7.75 7.75 42.3 150. 197 165.1 7.75 sw 7.755w 48.0 197 9.00 197 . 9.00 21.8 62.0 10 10 1½ X X 250 250 40 229 229 28.1 2 9.00sw I 9.00sw 62.0 50 229 4 229 28.1 9.00sw 9.005w I 62.4 2½ 65 229 229 28.3 3 9.00sw +----- 1- 9.005w 60.0 80 229 - 229 --- - 27.2 __ 4 900 sw 9.00sw 61.0 100 229 229 ' 27.7 -- 5 9.00 SW ' 9.00sw 52.0 125 229 229 ' 23.6 -1---- -* 6 9.005w ' 9.00 sw 59.0 150 229 _ ' 229 26.8 8 9.00sw 9.00sw 64.7 200 229 229 , 29.3 'r 11 11 &K L 12 12 X 1 10.005w 10.00sw ' 77.0 300 300 25 254 254 349 2 10.00sw 10.00sw 80.0 50 254 254 36.3 2½ 1a00sw 10.00 s - 7&0 65 254 254 35.4 ----.--.------~---- 3 10.00sw 10.00sw 82.0 80 254 254 37.2 - 4 10.00sw 10.00sw 80.0 100 254 254 36.3 ----- .-- - 5 10.00sw ' 10.00sw 75.0 125 254 254 . 34.0 -.------- -t 6 10.00sw 10.005w 75.0 150 254 -25-4-- I ' 34.0 8 - --- -., 10.00sw 10.00sw 80.0 200 254 254 36.3 10 10.00sw 10.00sw 84.0 250 254 254_ 38.1 #14 14 x 4 11.00 sw 11.005w 102.0 350 350 100 279 I 279 46.3 6 , 11.00 sw 11.005w - -. 108.2 150 279 279 49.1 - .- . ------.----f----------- - 8 11.00 11.00 112.0 200 279 __ 279 -------- 50.8 10 11.00 11.00 120.0 300 279 279 54.4 12 11.00 1100 129.1 300 ---279- 279 58.6 - + -.---- 916 16 .4 130.0 400 X 400 X 100 + + 59.0 14 - 60' AOS'For 350-1500mm AGS fitting information, see publication 20.05 + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an 'sw" or "s" S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. # For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. www.victaulic.com _JtauIic vIcTAuLIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REVR 0701_11 CARBON STEEL PIPE - GROOVED FITTINGS Grooved End Fittings Reducing Tee NO. 25 Grooved Branch NO. 29T Threaded Branch Cap 1=0 IM , #16 16 6 12.00sw 12.005w 133.5 400 400 150 305 305 60.6 - - 8 12.00 12.00 145.0 200 305 305 - 65.8 10 12.00 12.00 149.5 250 305 305 67.8 - -- .-.----- 12 12.00 12.00 154.0 300 305 305 69.9 4- --- - - -- 14 12.005w 167.0 350 305 - 75.8 + --.- # 18 18 4 15.50sw 15.50sw 194.0 450 450 100 394 394 ' 88.0 6 15,50sw 15.505w 200.0 150 _21 - 8 15.50sw 15.50sw ' 202.0 200 394 394 91.6 --4-..... 10 15.50 15.50 212.0 250 394 -- 394 96.2 . --. 12 15.50 15.50 , 222.6 300 394 394 4- 101.0 ____ - - 14 15.50 230.1 350 394 - , 104.4 - 16 15.50 247.6 400 - 394 - 112.3 -- #20 20 x 6 17.25 17.25 240.0 500 >< 500 150 438 438 1089 I --- ----- 8 17.25 17.25 244,0 200 1 438 438 11107 10 17.25 17.25 256.0 250 438 438 -- 116.1 - 12 17.25 17.25 1 264.0 300 438 438 1198 14 17.25 275.0 350 438 . - 124.7 07.01 .-CtoE1 .-CtoE.1 LT--Ito to NO. 25 NO. 291 #20 20 16 17.25 288.6 500 500 400 438 ' - 130.9 18 17.25 ' 297.0 450 438 - - ----4- - - - 20.00 20.00 134.7 -4- ' 340.0 24 24 8 x 600 600 >< 200 508 508 - - ---4- - --- - 154.2 10 20.00 20.00 - , - - -- 343.9 250 508 508 - ,-..- . 156.0 12 20.00 20.00 352.8 300 508 508 160.0 -----.- ----- 14 § 20.00 360.0 350 508 - 163.3 16 20.00 378.0 400 508 - 171.5 - 18 § 20.00 380.0 450 508 - 4- - - - 172.4 -± .- . - 20 20.00 373.0 500 508 - 169.2 350-1500mm AG8For AGS fitting information, see publication 20.0 + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an "sw' or "s" S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. # For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Cast fitting available. Contact Victaulic for details. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.0112 \4taulic! REVR INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. UPDATED 08/2012 07.01 1449 REV R '%j4taUIiC' VICTAULIC IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01 Rigid Coupling STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining. The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe 1¼ 175 365 365 365 365 32_ 1206 .2517 2517 2517 2517 11/2 175 365 365 36~ 3C5 40 •6 2517 t 2517 --t-- 2517 2517 50 1206 4.417 2517 2517 2517 . N 365 365 365 365 2517 2517 2517 _2517 76.1 mm N/A N/A 4-2151177 365 365 25l75 ,17 N/A 365 365 365 365 80 - 2517 2517 2517 2517 - 108 mm - N/A , ..- N/A N/A - 4 365 365 365 365 2517 2517 2517 2517 133 mm N/A 290 365 1999***.2517............. N/A N/A 139.7 mm N/A N/A 290 . 1999 232 365 1600 . 2517 165.1 mm - I N/A N/A 290** _17 1999** 232 365 1600 2517 N/A T90 45 232 365 150# 1999 . 2517 1600 2517 * Listed/Approved for wet and dry pipe systems (>40*F/4O*C). Please refer to the Victaulic Installation Manual (I-009H_009_009V.pdf) for details concerning when supplemental lubrication is required. ** EN-10219(L) for 76.1mm size; EN-10255(M) Regional availability only# FM Approved only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved www.victaulic.com vIclAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVG \4taulicr 10.61_i IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling STYLE 009H LISTINGS/APPROVALS * Speciality Pipe 300 300 300 300 300 300 BLT 1 /42 2068 '2068 EZT 1%-22 MT 206 i%_28 2068 300 300 300 300 300 OF 1/4-4 2068 2068 FF 1 %-4 2068 2068 MLT 1,S-2 N/A 2068 DT 1¼-2 300 —300- 2 2068 FLF 1¼-4 N/A 300 2 ST 1¼-2 N/A 300 2068 EF 1¼4i616 175 175 FLT ih/42__N/A 08STF i¼-4N/A 300 300 300 EL 1¼-2 2068 2068 2068 300 FLTL 114-2 N/A 2068 TF 24-4 N/A 2068 300 300 I 300 300 300 300 ET40 1/42 2068 ~2068 GL 11/4-2, 2068 WLS 1/42 ~ 2068 ~2068 300 300 300 300 175 EZF 3-4 2068 2068 MF 14-4 2068 2068 tA/ST 1,4-1206 XL 11/4-2 300 300 2068 2068 Note: The Specialty Pipe table only applies to imperial sizes, NOT to metric sizes. www.victaulic.com 'N ictsulid VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.612 REV_C IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS rn I J --. ii i ILiIiIIIJLI]L x 1¼ 1.660 365 790 0.10 2 - 3/8 x 2 2.95 4.77 2.70 4.63 1.93 1.4 32 42.4 2517 3514 2.54 : - MID x2 75 121 69 118 49 0.7 'r --" '' " - 9- - - 1½ 1.900 365 1035 0.10 2 - 3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 4604 2.54 - M10 x 2 81 126 75 122 _49 0.7 - -4-- -- -- -- STYLE 009H PRE-ASSEMBLED 2 2.37 5 365 1616 0.12 2 - 3/8 x 2 . 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 . 3.05 - Mb x 2 96 140 88 138 49 0.9 21/2 2.875 365 2370 0.12 2 - 3/8 x 21/2 4.29 6.09 3.92 5.85 1.93 2.1 4 Y # 65 73.0 2517 10542 3.05 -M10x2½ ' 109 155 100 149 49 1.0 --4--- -- - ; -- + -4- -- 3.000 365 2580 0.12 2 - 3/8 x 2 ½ 4.40 6.31 4.05 5.90 1.9376.1 ' 2.1 mm 76,1 2517 11476 3.05 -MID x2½ 112 160 103 150 49 1.0 -4-.-- x 3 3.500 365 3512 0.12 2 - 3/8 x 2½ 1 4.91 6.70 4.55 ' 6.46 1.93 2.3 80 88.9 ' 2517 15622 3.05 I -MID x2½ 125 170 116 164 49 ' 1.0 108 mm 4.250 365 5178 0.17 2 - 3/8 x 2 1/2 5.56 7.61 5.27 7.51 2.14 2.8 108.0 2517 23030 ' 4.32 -M10x2½ 141 193 134 . 191 54 1.2 - 4-___.___ ---9-------4----+- 9 '' STYLE 009H JOINT ASSEMBLED 4 4.500 365 5805 0.17 2 - 3/8 x 2½ 5.95 , 7.82 5.54 747 2.14 2.9 100 114.3 2517 25822 4.32 - MIO x 2½ , 151 199 141 190 55 1.3 ---4-----4----+---9----- 133mm 5.250 365 7900 0.17 2 - 3/8 x 2 ½ 6.66 ' 9.11 6.36 9.01 2.14 4.3 133.0 2517 35140 4.33 - MID x 2½ 169 232 162 229 55 1.9 + - 4- 5.500 365 8620 0.17 2 - 3/8 x 2 ½ 6.75 , 9.29 6.46 9.23 2.09 4.6 139.7 mm 139.7 2517 38340 4.32 - Mb x 2½ 172 236 164 234 53 2.1 --+ - - - - ± .........-4---- 1651 mm 6.500 290 , 9623 0.17 2 - 5/8 x 3¼ 7.84 10.93 7.55 10.85 2.11 5.69 165.1 . 1999 42805 4.32 -M16x3 1/4 199 278 192 276 54 2.6 ._4- - -F .4 - . -9- -, 6 6.625 290 9997 0.17 2 - 5/8 x 3¼ 7.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 . -M16x3 1/4 202 281 . 195 305 , 54 2.69 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See page 1 of this document for Listed/Approved ratings on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown in the chart on page 1, specific to pipe schedule and size. The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15; is available upon special request. Housing Coating: Orange enamel (North America, Asia Pacific) Red enamel (Europe) Optional Coatings: Hot dipped galvanized Gasket: Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com \jb4tauIice vIcTAuLIc IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 10.613 STYLE 009H GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No. 006 end caps containing the EZ" marking on the inside face or No. 60 end caps con- taining the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling. There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade E" Type A gaskets. These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop, that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.61 5731 REV G UPDATED 09/2012 ictaulic VICTAULIC IS REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2012 VICTAULIc COMPANY. ALL RIGHTS RESERVED. 10.61 Victaulic® Flexible Coupling Style 75 Exaggerated for clarity Approvals/Listings Z0ILPCBI nu-® € See Victaulic publication 10.01 for details See Victaulic publication 0206 for portable water approvals if applicable htauiic 06.05 I àWARNING Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 updated 09/2014 © 2014 Victaulic company. All rights reserved. 1 X 0 Ac-taulic victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) LI Standard: Orange enamel. LI Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE: Additional gasket styles are available. Contact Victaulic for details. Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30"F to +230"F/-34"C to +110"C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73"F/+23"C and hot +180"F/+82"C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. fl Grade "1" Nitrile Nitrile (Orange stripe color code). Temperature range 207 to +180"F/29"C to +82"C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150"FI-i-66"C or for hot dry air over +140"F/+60"C. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 \jtaukc victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Dimensions Style 75 lei 1 11511 1 11111 'At III Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure 2 Load 2 Separation Centerline Bolt/Nut4 X Y Z Each Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. mm mm kPa N mm Degrees mm/rn (No.) size inches mm mm mm kg 1 1.315 500 680 0-0.06 0.57 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 2-43' 48 2-3/8x2 61 108 45 0.6 1 1/4 1.660 500 1080 0-0.06 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2 -10, 38 2-3/8x2 68 117 45 0.6 1 1/2 1.900 500 1420 0-0.06 1 -56' 0.40 2-3/ax2 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 33 74 122 45 0.6 2 2.375 500 2215 0-0.06 0.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 1 -31' 26 2-3/8X2 87 133 48 0.8 21/2 2.875 500 3245 0-0.06 0.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1 -15' 22 2-3/sx2 98 144 48 0.9 76.1 mm 3.000 500 3535 0-0.06 1 -12' 0.26 2-3/8x2 4.00 5.90 1.88 1.9 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4800 0-0.06 0.22 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 1 - 2' 18 2-½x2~ 114 178 48 1.3 31/2 4.000 500 6300 0-0.06 0.19 5.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 0-54' 16 2-½x2 3/4 127 191 48 1.3 4 4.500 500 7950 0-0.13 1 -36' 0.34 2-½x2~ 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 147 204 54 1.9 108.0 mm 4.250 450 6380 0-0.13 1 -41' 0.35 2-12x70 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 29 141 198 54 1.7 41/2 5.000 450 8820 0-0.13 0.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 1 - 26' 21 2-5/8 x3 1/4 _________ 156 240 54 2.5 5 5.563 450 10935 0-0.13 1 -18' 0.27 2-%x3¼ 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 23 175 256 54 2.6 133.0 mm 5.250 450 9735 0-0.13 1 -21' 0.28 2-16x82.5 6.55 9.37 2.13 6.0 133.0 3100 43325 0-3.2 24 166 238 54 2.7 139.7 mm 5.500 450 10665 0-0.13 1 -18' 0.28 2-¼x3¼ 6.80 9.59 2.13 6.3 139.7 3100 47460 0-3.2 24 173 244 54 2.9 152.4 mm 6.000 450 12735 0-0.13 1-12' 0.21 2-5/a x3¼ 7.38 10.48 1.88 6.2 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15525 0-0.13 1 -5' 0.23 2-%x3¼ 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 18 203 281 54 3.2 159.0 mm 6.250 450 13800 0-0.13 - 1 9' 0.24 2-16x82.5 7.63 10.49 2.13 6.8 159.0 3100 61405 0-3.2 20 194 266 54 3.1 8 8.625 450 26280 0-0.13 0.18 10.34 13.97 2.13 12.4 200 219.1 3100 116945 0-3.2 0 - 50' 14 2- 3/4 x 4¼ 263 355 59 5.6 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 1/4 -3 ½"I20 -90 mm; 25% for 4/100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 \/taUIiC victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Installation Reference should always be made to the 1-100 Victaulic Field Instuilation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.oictaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulice is a registered trademark of Victaulic Company. 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 4 'j4'tauiic FireLock® Fittings 4tauIic 10.03 Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: El Orange enamel O Red enamel in Europe, Middle East, Africa, and India o Optional: Hot dipped galvanized Approvals/Listings: USTED Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 © 2014 victaulic company. All rights reserved. 1 Zictaullicr victaukc.com I FireLock® Fittings I Publication 10.03 Dimensions: C to E 1 LO NO. 001 toE I Cto to E 1b _ NO. 003 NO. 002 No. 006 No. 001 No. 003 No. 002 No. 006 900 Elbow 450 Elbow Straight Tee Cap Approx. Approx. Approx. Approx. Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. mm mm mm kg mm kg mm kg mm kg 11/4 1.660 0.82 0.3 32 1 42.4 - - - - - - 21 0.1 11/2 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 3.00 3.8 76.1 76 1.5 57 1.1 76.2 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 39.7 mm 5.500 4.88 12.4 3.25 8.2 4.88 15.4 139.7 124.0 5.6 82.6 3.7 124.0 6.9 - 159mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 1651 mm 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 139.7 7.9 88.9 5.2 139.7 9.9 - - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 10.03 1539 Rev M updated 12/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 2 \JtaUIiC Mechanical-I® STYLES 920 AND 920N STYLE 920 CROSS PATENTED STYLES 920 AND 920N Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/345OkPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special K request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location Approved Date www.victaulic.com viciuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 viciuic COMPANY. ALL RIGHTS RESERVED. REVM \4taukc 11.021 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Y ____ Z GI 1 IiD I -mm -- - JL i 2 /2(a)a 500 1.50 1 2.002,53 1.61 5.35 2.75 3.1 I 50 15 N 3450 38.1 51 64 - 41 136 70 1.5 - V I IK (a) a 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - - -- - 1(a) a 920½ 500 1.50 . 1.85 2.53 1.61 5.35 2.75 3.0 W 25 3450 38.1 47 64 - 41 136 70 It 1.4 - - .._.4-, -- -4-- -. .4... - --I-__.+.... .-4. ,.._ -. __•. - 1 1/4(a) ta 920N 500 1.75 2.05 2.75 3.00 1.61 .5.35 3.00 . 3.5 3.2 GROOVED OUTLET 32 - 44.5 52 70 76 414_1364_j17_41.5 1½ (a) j-a 500 1.75 2.03 . 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 920N 3450 44.5 52 70 79 41 136 83 1.7 I 1.5 -4.- ---4-- -+ -1---- --4- --'- --- - - - -4-- --__________ - V *-z----i 2½ ½ (a) 920½ 500 1.50 2.21 2.74 1.82 5.64 2.75 30 - 65 15 3450 38.1 56 70 - 46 143 70 1.4 - 3/4(a) 920½ 500 1.50 2.18 2.74 1 82 I 5.64 . 2.75 30 V 20 - 3450 31 55 70 46M3 70L4 1(a)5a 920N 500 1.50 26 25 3450 38.1 52 .2;4 _ 182 4 2 46 143 77: 2.9 1.4 W 1¼ t (a) a 500 1.75 2.30 . 3.00 - 3.25 1.82 6.29 3.00 3.5 3.2 32 920N 3450 44.5 58 76 83 46 160 76 1.7 1.5 11/2 t (a) a 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 FEMALE THREADED OUTLET 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 ½(a) 300 - 1.50 2.22 2.75 2.25 6.46 3.18 3.9 - 15 2065 1 38.1 56 70 - - 57 164 81 1.8 - Provides a direct branch connection at 3/ (a) 920N 300 150 219 275 225 646318 39 any location where a hole can be cut 20 2065 38.1 56 I_70 I ___57 164 81__ 1,8 in the pipe 1(a) 920½ 300 1.50 2.07 2.75 - 2.25 6.46 3.18 3.8 - 25 2065 38.153 '70 57 164 81 1.7 + • A pressure responsive gasket provides i ¼ (a) a + 500 1.75 2.30 3.00 3.31 I_ 1.92 6.29 3.00 3.5 3.2 the e 32 920N 3450 44.5 58 76 84 49 160 76 1.6 1,5 ______ f. - 1½ (a) a 920½ . 500 2.00 2.28 3.00 3.31 1.92 . 6.29 , 3.25 3.5 3.3 Request Publication 11.03 for 40 - - 3450 50 58 76 84 49~ 160 83 1.6 1.5 Mechanical-I cross assemblies 3 ½ (a) a 920N 500 1.50 2.52 3.05 - 2.28 6.15 2.75 3.4 - 80 15 3450 38.1 64 78 58 156 70 1.6 Pressure rated up to 500 psi/3450 kPa Y. (a) a 92 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe; also available for use 20 -. , 3450 381 -~ 63 78 - - .58 156 70 1.6 with HDPE nine 1(a) 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 I 78 . - 58 ' 156 70 1.6 -.---.----4.-. --t------+------4--- .........,. .........__.... Sizes from 2 x ½'/50 x 15mm 1¼ (a) ta 500 1.75 2.55 3.25 I 3.56 2.28 ' 6.15 , 3.00 3.8 3.7 32(b) 920N uirougHox'/LJuxJuumm 3450 44.5 _65 83 90 58 ' 156 76 . 1.8 . 1.8 - - I_-.------~ - 4-. .. ... .~.. 11/2 (a) ta 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 . 3.8 40(b) 920N 3450 50.8 I 71 89 90 58 156 83 1.9 1.8 -t-----1-- ± - - +- -'--- - '-4-- - '- '--4- - -1-- 2 (a) a 500 2.50 2.75 I 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 920N 3450 63.5 70 89 90 58 172 99 2.3 - 2.1 '-----'------t----H----4- ---1----i 4-- ---1--- 3½ 2 920N 500 2.50 3.00 . 3.75 ' 2.44 . 6.72 3.88 3.8 90 __50 345063.5 -76 _- _95 _62171 .99 _-1 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG. 3 Style 920 and Style 920N housings cannot be Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). mated to one another t Available with grooved or female threaded outlet. Specify choice on order. to achieve cross connections. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ° LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. * 2012 VICTAIJLIC COMPANY. ALL RIGHTS RESERVED. 11.022 JtauIicr REV_M GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 20 _________________Gr 1A ______________________ Inc en TABLE CONTINUED FROM PAGE 2 I 4 1/2 (a) n 920½ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 100 15 3450 38.1 77 90 - 68 178 70 1.8 - - . , t _4 _. . - - . - 34(a) n 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 1.8 - 4. .. -I- 1(a) n 500 1.50 2.88 3.56 . 2.69 7.01 2.75 3.6 25 3450 38.1 73 ' 90 - 68 178 70 1.8 - - - ._4. - . ._.4. ._ _ - 4- - 4" 4---- 11/4 (a) to 500 1.75 3.08 3.78 400 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 -. .4. 78 96 . .,.... 102 68 178 +- -- 76 - 1.9 1.8 11/2 (a) to 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2,0 1.9 - -'-----4--.-- I- - -4'--. - I--. - - -- -- - - -'1- 2 (a) to 920N ' 500 2.50 3.25 4.00 ' 4.00 ; 2.69 7.01 3.88 5.0 1 4.6 50 3450 63.5 83 102 102 . 68 178 99 2.3 2.1 • . .f I "--+ - - 4---------- 2½ (a) t 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 58 50 65 920 3450 69.9 73 102 102 68 186 118 2.6 . 2.3 --'-H---- ' ----•- --- mm 500 4--' ----'----4--'--,--•+ 76.1 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 - 102 68 186 118 - 2.9 +---- 3(a) t 500 ' 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 1 ¼ (a)n 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 • 32 3450 44.5 78 96 - ' 67 194 78 2.3 - '4- -. "- - 4-- --'-- '4-' - 4.' -- (a)e 500 + 11/2 ' 2.00 3.28 4.00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102, - 67 194 83 2.3 - ____ - .4-.. _• 4_,_ _, 4-__ 4, . 4, - __ 4- _-4••.. .,,4,,_,.. 2 (a) - 500 2.50 ' 3.25 4.00 . 2.63 7.64 4.00 4.0 50 . 3450 63.5 83 102 - 67 194 102 1.9 - 4--- .---4--------- -4------- -,-.--+, - - + - " - . + - 4' - 500 2.75 2.88 4.00 4.00 , 2.63 7.64 4.29 8.0 7.8 76+1 mm 920 3450 69.9 73 102 102 67 194 109 3.6 . 3.5 - -'. --1---------4------'-t---- 3-'---- 4--- -I----- -+ - ' '- - + - 3(a) 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 920 3450 88.9 84 . 114 114 67 194 124 3.1 3.0 - •- -t----I- - '- -- -'- .--.-.-----4-, --------'------+,- 5 x 1 ½ (a) t 500 2.00 4.03 ' 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 920 3450 50.8 '102 121 121 80 246 94 3.4 3.4 500 -1---- I 2.50 4.00 4.75 1- -1---- 4.75 3.16 -4----- - 4-- -- - - 4.38 9.70 - -- + 8.2 . - 8.0 2 (a) t 50 920 3450 63.5 102 121 121 - 80 - - - 246 111 - - - 3.7 ' 3.6 + ',----*---+--- -4- - - - --- 2½ (a) t 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 920 3450 69.9 . 92 121 121 80 246 118 3.8 3.6 4 'f mm 500 3450 4. 76.1 2.75 69.9 3.75 95 - 4.75 , 121 3.16 80 9.70 246 4.63 118 ' - 8.0 3.6 ______ - - - I 4-.-- f ----4- - '- -~-- - 3(a) t 500 3.50 1 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 920 ' 3450 88.9 97 127 118 80 ' 246 135 3.8 4.0 ---------- 2 500 2.50 3.75 4.50 3.17 8.00 3.88 80 133.C x 50 3450 63.5 95 114 , - 81 203 99 3.6 - '-"- '4---'-+'" -1----'-----t- --4---- 80 920 500 . 3450 , 3.50 88.9 3.81 97 5.00 127 - 3.00 76 9.46 240 5.31 135 80 36 - TABLE CONTINUED ON PG. 4 " Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAIJLIC COMPANY. © 2012 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_M 11.023 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS I M) 1[ 9- ft V I Tff- A OD Y M am Ma i~1 ½ I' 500 200 3.78 4.50 - 3.30 8.23 3.25 7.0 139.7 x 40 920N 3450 50.8 96 114 84 209 83 3.2 - TABLE CONTINUED FROM PAGE 3 - 2 t 920N 500 2.50 I 3.75 4.50 H - .30-1 8.23 3.88 9.0 50 3450 63.5 95 114 84 ' 209 99 4,1 - - ---t---- I 6 1 920N 500 , 1.75 4.43 i 5.13 5.13 3,79 9.15 3.25 5.1 4.8 150 X 32 (b) 3450 ' 44,5 . 112 130 130 96 232 83 2.3 2.2 '-4----- -- -- I GROOVED OUTLET 1 ½ (a) to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112J. 130 130 96 - 232 + 83 2.4 2.3_ -4 -1- 2(a) to 920N 500 2.50 I 4.38 I I 5.13 5.13 3.79 9.15 3.88 . 6.0 5.6 ________ 50 , 3450 ' 63.5 111 130 130 I 96 232 99 ' 2.7 2.5 21/2 920 ' 500 2.75 ' 4.01 - 13 ' 5.12 3.69 10.51 4.63 8.3 7.6 ______ 65 ' 3450 69.9 ( 1 1 ,4 130. 130494 267 118 3.8 3.4 - + 76.1 mm a 920 4--- 500 2.75 4.15 5.21 3.69 10.51 ' 4.63 8.4 3450 69.9 105 I - 132 ' 94 267 118 - 3.8 I_--_-- 3(a)') 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8,4 80 3450 1 88.9 - - - -. 110 140_4 130 94 267 135 4.5 3.8 -- 4(a) to 920 500 1 4.50 3.81 5,75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 i 267 159 4.6 _4.6 FEMALE THREADED OUTLET .' I_'"4 -- 1 ½ (a) 500 2.00 4.41 5.13 - 3.63 9.40 3.25 7.8 - 920N 159.0 x 40 3450 50.8 112 _130 92 239 83 ' 3.5 920N 500 2.50 4.38 I_5.13 3 - - - 9.40 3.88 8.0 Provides a direct branch connection at so 3450 63.5 111 130 4 92 239 99 3.6 - -t , -.4- - .4.. any location where a hole can be cut 76.1 mm 920 500 2.75 . 4.38 5.50 ' 513 ' 3.63 9.40 . 4.63 ' 9,5 9,5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 ' 3.50 4.31 5.50 5.13 ' 3.63 9.40 5.31 8.1 14.0 A pressure responsive gasket provides 920 3450 88.9 110 : 140 130 92 239 135 ' 3.7 6.4 I - I -t----------------4----- - I the seal 108 0mm 920 500 4.50 ' 4.45 5.38 3.63 I 9.40 . 6.12 10.0 3450 114.3 113 1" 137 92 239 155 4.5 Request Publication 11.03 for . - I ' I 920 ' 500 ' 4.50 3.81 5.75 363 I 940 625 180 - Mechanical-I cross assemblies 100 3450 114.3 96.80 . 146 - 92 i 239 ' 159 8.2 TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450 kPa center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order. with HDPE pipe Center of run to end offitting. Sizes from 2 x 1/2150 x 15mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4/200 x 100mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT' clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services -PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in china by Tianjin Approvals company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victauIic.com VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2012 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 \4taulicr REV_M CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 MechanicalT® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS & Jim _ .rEsa _ _ _ TABLE CONTINUED _FROM _PAGE _4 500 1.50 3.88 4.56 3.79 934 2.75 8.0 165.1 x - 920N 3450 38.1 99 116 - 96 237 70 3.6 - 11% 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 - - -,- - -4---- 1 i - -1-- -- 4- 1½ (a) t 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 ---4----'_I -"-4-- --- --4--- '-1-- ~ ._ GROOVED OUTLET 2(a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 . 63.5 111 130 130 96 237 99 . 3.9 2.7 + --4 - -'4-- + - + 76.1 mm 920 '- 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 ________ 3450 69.9 110 130 132 92 . 267 ' 118 3.9 3.4 Fir 3 (a) 'f 0 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 38 - -•- - -------- + - 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 920 8 2(a) 8 920 500 275 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 X 50 3450 . 69,9 138 , 157 159 ; 122 316 114 5.3 5.3 _4_ __ +----F------'- - - -4-- - -4--- -i-- - + -.--I-- 21/2 -4----- (a)t - 920 500 2.75 5.07 6.19 6.19 4.81 . 12.42 4.50 11.6 11.6 65 3450 . 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET -4- 4-- - 4- --4--- ''-----4-- - -- ''9- . - 3- 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 76.lmrnD 920 3450 69.9 133 - 159 122 . 316 116 - 5.3 3- -.-. i------4- -'---1- +- -4- 3(a) t 920 500 3.50 5.31 6.50 6.50 , 4.81 12,42 5.31 12.6 11.6 Provides a direct branch connection at 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location location where a hole can be cut 4(a) 920 500 4.50 4.81 ' 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 - 3450 114.3 122 , 171 , 162 122 316 159 , 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). A pressure responsive gasket provides t Available with grooved or female threaded outlet. Specify choice on order. the seal * Center of run to end of fitting. Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' Pressure rated up to 500 psi/3450 kPa (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. with HDPE pipe § Vds approved for fire protection services LPCB approved for fire protection services Sizes from 2 x 1/2750 x 15mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.viCtaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vICTAuLIC COMPANY. © 2012 vIcTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_M 4taUiicr 11.025 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C5,,K Values: AP = Q2 Where: AP = - Where: Q = C x C = Flow Coefficient Q = K = Pressure Drop (bar) Q = Flow (GPM) K Q = Flow (m3/h) AP = Pressure Drop (psi) AP K =Flow Coefficient Exaggerated for clarity Equivalent Outlet Size 40 Carbon Length of Schedule Steel Pipe OUTLET SIZE ' I. (e.II388i] - j]1 2 . I!LrlI.c-.I. ii"riviai 11 ½ 0.840 15 3 -----.----- 1.050 3/4 9.4 - . - - 16 20 -- 26J - - - - 4 - - -...__-. 13.7 1 1.315 21 25 7 -. , 4.. 1.8 1 1/4 1.660 6 50 48 32 7._ _._. .42.9 iJ 1.900 . . . 53 53 40 983 11 11 45.4 ------- 45.4 2 2.375 9 10 /2 112 104 50 60.3 - 96 - 89.1 2½ 2.875 65 73,0 - 20 - 12/2 119 102 150 128.5 3.000 76.1 mm 76+1 16 161 - - L ..._138.1 - 3 3.500 249 237 80 - - 88.9 14 -- 15 1/ . 2 .__.L 213.4 4.500 20 22 421 401 100 114.3 360.8 . 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. www.victaulic.com IN ictaulid vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. J_~_c 11.02_6 REVM CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2 -6 2.875 -6 ' 625 All 10,40 400 400 400 290 232 362 65-150 73.0- 168.3 2.875 - 4.500 All DF 2755 300 2755 300 1 2755 300 1999 290 1599 232 2496 362 21/2-4 65-100 730-114.3 - 2.875 - 4,500 All —+- --1--- SF 2065 I 300 2065 -_I 300 1 2065 ---i----- 300 1999 --- -- 290 1599 ---- ... ...... 232 2496 ... .+-. - 362 21/2-4 65-100 73.0-114.3 6.625 I 3,4 ---I-.— 4 10 2065 300 2065 - 300 I 2065 250 --i---- 1999 290 . -'+-.---- 1599 232 2496 -,- - 362 6 150 168.3 6.625 34 30 40 ---------------------------------------- 2065 300 2065 300 I I 1724 300 I 1999 290 1599 232 2496 362 6 150 168.3 8.625 1 21/2 . 4_.__.__ . 2065 +-. 400 2065 ----.-+----.-- 2065 1999 1999 1599 1599 145 2496 8 200 219.1 8.625 I3,4 ' 10 2755 300 — — — -- 250 — . - — 1000 145 — + ........ — 8 200 219.1 8.625 34 3040 2065 300 .+------ — -+ -- 1724 300 . . . — 1000 . . 145 — 8 200 219.1 ' 2065 i 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 87100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-I and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-I unit is a full port ball valve which can be mounted on 4/100mm, 5/125 mm, 67150 mm and 87200 mm diameter pipe. The Style 931 comes with a 2 ½765 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com vlcrAuuc IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X.A—c—tau I i C~ REVM 11.027 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 ictaulic VIcTAULIc IS REGISTERED TRADEMARK OF VICTAULIc COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1LO2L u mMAIA F'Opu'ngjjijj IiiiTc1s Malleable Threaded Fittings ALL MALLEABLE THREADED FITTINGS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 197- Standard Spec for Cupola Malleable Iron ASTM A 153- Standard Spec for Zinc Coating (Hot Dip) on Iron and Steel ANSI B 16.3- Malleable Iron Threaded Fittings Classes 150 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Ductile Iron Threaded Fittings ALL DUCTILE IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: 9M ASTM A 536- Grade 65-45-12 ASME B 16.3- Ductile Iron Threaded Fittings Classes 150 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Cast lronThreaded Fittings ALL CAST IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 128- Class B Standard Spec for Cupola Cast Iron ANSI B 16.4- Cast Iron Threaded Fitting Classes 125 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Steel Pipe Nipples ALL STEEL PIPE NIPPLES MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 53- Standard Spec for Pipe, Steel, Black and Hot-Dipped, Zinc Coated, Welded and Seamed ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT www.sigmaco.com MSUZU8 nmd(W rtroj El Dimensions: ANSI B16.3 CLASS 150 [1 Coating: Black- none; Galvanized- Hot Dip per ASTMA153 El Material: Malleable iron per ASTM Al 97 []Threads: Pipe Threads, General Purpose ASME B1.20.1 Description 1 1 1[NUM1 [JzEJ[BLACKjLGALVJLA][ ITEMDE II D1EN1 ITEM Wj[jtfJ1 Malleable Threaded 90 A 3/8" 1M90B0303 1M90B0303G 0.95 0.95 0.17 1/2" 1M90B0404 1M90B0404G 1.12 1.12 0.30 - 3/4 1M90B0505 1M90B0505G 1.31 1.31 0.45 1" 1M90B0606 1M90B0606G 1.50 1.50 0.73 1 1/4 1 M90B0707 1 M90B0707G 1.75 1.75 0.97 / 11/2" 1M90B0808 1M90130808G 1.94 1.94 1.30 / 2" 1M90130909 1M90130909G 2.25 2.25 2.06 2 1/2" 1M90131010 1M90131010G 2.70 2.70 355 3" 1M90B1111 1M9081111G 3.08 3.08 5.46 F LISTED 4" 1M90B1212 1M9081212G 3.79 3.79 8.95 Description l I I 'I NOM II JTEMiQDIE I1IIDIMENS1cJN1I iTEM Malleable Threaded 45 3/8" . 1M45B0303 1M45B0303G 0.80 0.80 0.16 A 1/2" 1M45B0404 1M45B0404G 0.88 0.88 0.22 3/4 1 M45B0505 1 M45B0505G 0.98 0.98 0.37 1" 1M45130606 1M45B0606G 1.12 1.12 0.54 1 1/4 1M45B0707 1M45B0707G 1.29 1.29 0.86 11/2" 1 M45B0808 1 M45B0808G 1.43 1.43 1.13 2 1 M45B0909 1 M45B0909G i. 11.68 1.68 1.79 B 2 1/2" 1M45131010 1M45B1010G 1.95 1.95 2.78 Ut 3 1M45B1111 1M45B1111G 217 1 217 448 I LISTED " 1M45B1212 1M45B1212G 2.61 2.61 7.40 Description 1 1 I 1 II NOM I ITE ]1MENI ITEM1 !iJLwE1~i-tT I ded9O Malleable Thre tree 3/8" 1M90S0303 1M90S0303G 0.80 1.00 0.17 1/2" 1M90S0404 1M90S0404G 0.88 113 0.24 3/4 1M90S0505 1M90S0505G 1.00 1.31 0.41 1M90S0606 1M90S0606G 1.23 1.44 0.62 / ( 11/4" 1M90S0707 1M9080707G 1.31 1.69 1.09 Ut 1 1/2" 1M90S0808 1M90S0808G 1.44 1.88 1.44 I 1M90S0909 1M90S0909G 1.69 2.25 2.85 - A-] LISTED Description I I 1 NUM-11 SIZE J[BT.AC!JGALV I ITEM GOJIE I ITEM I Malleable Hex Nut 1/2" 1MLN04 1MLN04G 0.12 3/4" 1MLN05 1MLN05G 0.22 /1 1" 1MLN06 1MLN06G 0.38 \ ) 1 C)2" 1 1/4" 1MLN07 1MLN07G 0.58 o 1 1/2" 1MLN08 1MLN09 1MLN08G 1MLN09G 0.73 1.13 LISTED www.sigmaco.com 1 11 Malleable Threaded Description I ______________________ F 11 11 1TEMIDE 1[D1MENS1H1( ITEM Redung Malleable 1/2" X 3/8" 1M90R0403 1M90R0403G 1.00 1.06 0.22 B 3/4" X 1/2" 1M90R0504 1M90R0504G 1.19 1.25 0.38 1"X 1/2" 1M90R0604 1M90R0604G, 1.25 1.38 0.46 1" X 3/4" 1M90R0605 1M90R0605G 1.38 1.44 0.56 1 1/4 X 1/2 1M90R0704 1M90R0704G 1.38 1.56 0.61 1' A 1 1/4" X 3/4" 1M90R0705 1M90R0705G 1.44 1.63 0.71 1 1/4" X 1" 1M90R0706 1M90R0706G 1.44 1.66 1.15 f 11/2" X 1/2" 1M90R0804 1M90R0804G 1.41 1.66 1.15 1 1/2"X3/4" 1M90R0805 1M90R0805G 1.50 .L 1.75 1.08 I 1 1/2"X 1" 1M90R0806 1M90R0806G 1.63 1.81 1.02 Ui '11/2" X 1/4" 1M90R0807 .1M90R0807G 1.81 1.88 1.17 LISTED 2" X 1/2" 1M90R0904 1M90R0904G 1.49 1.88 1.30 2 X 3/4 1M90R0905 1M90R0905G 1.63 1 2.00 1.30 2" X 1" 1M90R0906 1M90R0906G 1.75 2.00 1.35 2"X 11/4" 1M90R0907 .1M9ç0907G.,. 1.881 2.13 1.5 2" X 1 1/2" 1M90R0908 1M90R0908G 2.00 2.13 1.75 Description L I 1 [SIZE]FJL.AW...jLJLWEFQftIJ 1 IIEM.CUL1E ILUIMJI ITEM I Malleable Threaded Tee 1/4" 1MT020202 1MT020202G 0.81 0.15 111111 I 3/8" 1MT030303 1MT030303G 0.94 0.23 A 1/2" 1MT040404 1MT040404G 1.13 0.41 I I 3/4" 1MT050505 1MT050505G 1.31 0.60 - 1- 1" - 1M1060606 1MT060606G, 1.50 0.90 I I 11/4" 1MT070707 1MT070707G 1.75 1.31 J L 1 1/2" 1MT080808 1MT080808G 1.94 1.73 2" 1MT090909 1MT090909G 2.25 2.52 - - - - A A 2 1/2" 1MT101010 1MT10I01OG, 2.69 4.90 3" 1MT111111 1MT111111G 3.06 7.13 LISTED 4" 1MT121212 1M1121212G 3.81 11.32 Description I I I L__ITEM COflE I1DIMil ITEM SIZECross 1Jt GAJV 11 A JLWEIG.HI Malleable Threaded A--A- 1/2" 1MX04 1MX04G 1.12 0.42 3/4" 1MX05 1MX05G 1.13 0.69 1" 1MX06 1MX06G 1.50 1.12 - 11/4" 1MX07 1MX07G 1.75 1.44 1 1/2" 1MX08 1MXO8G 1.94 1.98 2" 1MX09 IMX09G 2.25 3.30 2 1/2" 1MX10 1MX10G 2.70 5.90 @LISTED A 3" 1MX11 1MX11G 3.08 13.50 I www.sigmaco.com Malleable Fitt Description I I Malleable Reducing Tee I NOM ITEM CODE LDIMEN.. if ITEM L__ JL1LJLAJLJ]L - C 1/2 X 1/2 X 3/8 1M1040403 1MT040403G 1.06 1.06 1.06 0.30 3/4" X 1/2' X 1/2" 1M1050404 1MT050404G 1.08 1.08 1.09 0.38 3/4" X 1/2" X 3/4" 1MT0504051MT050405G 1.11 1.11 1.13 0.46 3/4" X 3/4" X 1/2" 1MT050504 1MT050504G 1.19 1.19 1.25 0.47 1 X 1/2 X 1/2 1MT060404 MT060404G 1 21 1 21 1 30 0 58 1" X 3/4" X 1/2" 1M1060504 1MT060504G 1.22 1.22 1.32 0.59 1"X3/4"X3/4" 1MTo6o5o51MTo6o5o5G[ 1.23 1.23 11.33 1.59 1" X 1" X 1/2" 1M1060604 1MT060604G 1.25 1.25 1.38 0.70 D 1 X 1 X 3/4 1MT0606051MT060605G 1 38 1 38 1 44 0 82 11/4" Xix 1" 1MT070606 1MT070606G 1.56 1.56 1.69 1.10 1 1/4 X 1 1/4 X 1/2 1MT070704 1MT070704G'[ 1 38 1 1 38 1 56 0 98 1 1/4" X 1 1/4" X 3/4" 1MT070705 1MT070705G 1.40 1.40 0.94 1 1 1/4 X 1 1/4 X 1 1MT070706 1MT070706G [ 1 56 r 1 56 1.60 i. 1.6-9 1 20 11/2" X 1/4" X " 1M1080706 1MT080706G 1.63 1.63 1.81 1.30 UL 1 1/2"X 1 1/2"X 1/2" 1MT0808041MT080804G:1 1.44 1 1.44 1.69 1.19 11/2" X 11/2" X 3/4" 1M1080805 1ML080805G 1.50 1.50 1.75 1.30 LISTED 1 1/2" X 11/2" X 1" 1M10808061MT080806&[ 1.63 1.63 1.81 1.45 11/2" X 1/2" X 1/4" 1M1080807 1MT080807G 1.81 1.81 1.88 1.52 2 X 2 X 1/2 1M1090904 1MT090904G[ 1 50 1[ 1.50 1.88 1.65 2" X 2" X 3/4" 1 M1090905 1 MT090905G 1.63 1.63 2.00 1.87 2 X 2 X 1 1M1090906 1MT090906G1 1.751-1. 1.75 200 1.76 2" X 2" X 1 1/4" 1M1090907 1MT090907G 1.88 1.88 2.13 2.35 2 X 2 X 11/2 1 M1090908 1 MT090908G L 2 00 2 00 2.19 2.55 2 1/2" X 2 1/2" X 1" 1MT101006 1MT101006G 1.88 1.88 2.38 2.85 21/2 X21/2 Xi 1/4 1MT1O1007 iMT1O1007G[ 206 206 244 336 2 1/2 X 2 1/2 X 1 1/2 1MT101008 iMT101008G 2.19 2.19 2.50 3.46 21/2 X21/2 X2 1MT101009 1MT101009G1, 238 238 262 365 3" X 3" X 1/2" 1M1111104 1MT111104G 1.76 1.76 2.52 4.03 3 X 3 X 3/4 1MT111105 1MT111105G 1.88 1.88 1.63 403 3" X 3" X 1" 1MT111106 IMT111106G 2.00 2.00 2.62 4.13 3 X3 X 1/4 1MT111107 1MT111'1d7d1 219 219 275 450 3" X 3" X 1 1/2" 1MT111108 1MT111108G 2.31 2.31 2.81 5.18 3 X3 X 2"1MT111109 k1MT111109G 250 250 288 570 3" X 3" X 1 1/2" 1MT111110 1MT11111OG 2.57 2.57 2.89 5.00 4X4 X 1/4 1MT121207 1M1121207G 239 239 326 747 4" X 4" X 1 1/2" 1MT121208 1MT111208G 2.51 2.51 3.32 7.47 - 4" X 4" X 2" 1MT121209 [1MT1212096 2.75 2.75 T 3.44 8.39 4" X4"X2 1/2" ' 1M1121210 1MT12121OG 2.75 2.75 3.44 7.70 4 X 4 X 3 1MT121211 J1MT1212116 331 331 363 893 Description [ I ., Malleable Cap LISTED I NOIVfl I ITEM GUDE If ITEM 1/2" 1MK04 1MK04G 0.14 3/4" 1MK05 1MK05G 0.21 1" 1MK06 1MK06G 0.37 1 1/4" 1MK07 1MK07G 0.58 1 1/2" 1MK08 ' 1MK08G -. 0.74 2" 1MK09 1MK09G 0.94 2 1/2" 1MK10 1MK10G . 1.60 1MK11 1MK11G 2.79 4" 1MK12 1MK12G . 3.66 www.sigmaco.com Malleable Threaded Description I Malleable Coupling HA I® LISTED I ITEMIC1L1E lI.DINL II ITEM SIZEI [BLACK ][GALV][A[v 3/8" 1MCP0303 1MCP0303G 1.18 0.13 1/2" 1MCP0404 1MCP0404G 1.31 0.20 3/4" 1MCP0505 1MCP0505G 1.50 0.30 1" 1MCP0606 1MCP0606G 1.69 0.48 1 1/4" 1MCP0707 1MCP0707G 1.93 0.75 1 1/2" 1MCP0808 1MCP0808G 2.13 1.00 2" 1MCP0909 1MCP0909G 2.50 1.45 2 1/2" 1MCP1010 1MCP1010G 2.88 2.40 3" 1MCP1111 1MCP1111G 3.19 3.30 4" 1MCP1212 1MCP1212G 3.69 5.72 I NOM SIZE ITEIIDUEI IIDIM1[ 1 ITEM [ [LJ[ GALV][A][JTJ 1/2" X 3/8" , 1MCR0403 1MCR0403G 0.17 0.17 3/4" X 1/2" 1MCR0504 1MCRO5O4G 0.27 0.27 1 X 1/2 1MCR0604 1MCR0604G 039 0.39 1" X 3/4" 1MCR0605 1MCR0605G 0.43 0.43 1 1/4" X 1/2" 1MCR0704 1MCR0704G 0.61 0.61 1 1/4" X 3/4" IMCR0705 1MCR0705G 0.64 0.64 - 1 1/4" X 1" 1MCR0706 1MCR0706G 0.68 0.68 1 1/2" X 1/2" 1MCR0804 1MCR0804G 0.78 0.78 11/2" X 3/4" 1MCR0805 IMCR0805G 0.88 0.88 1 1/2" X 1" 1McR0806 1MCR0806G 0.88 0.88 11/2" X 11/4" 1 MCR0807 1 MCR0807G • 0.90 :' 0.90 2" X 1/2" 1MCR0904 1MCR0904G 1.15 1.15 2" X 3/4" 1 MCRO9O5 1 MCRO9O5G 1.34 1.34 2" X 1" 1MCR0906 1MCRO906G 1.40 1.40 2" X 1 1/4" 1MCR0907 .1McRQ907? 1.53 •. 1.53 2" X 1/2" , 1MCR0908 1MCRO908G 1.55 1.55 2 1/2" X 1 1/4" 1MCR1007 1MCR1007G 2.09 2.09 2 1/2" X 1 1/2" 1MCRI008 1MCRIO08G 2.09 2.09 2 1!2"X2" 1MCR1009 1MCR1009G 2.51 2.51 3" X 1 1/4" 1MCR1107 , 1MCR1107G 2.99 2.99 3" X 1 1/2" 1MCR1108 .. 1MCR1I08G , 3.30 3.30 3"X2" 1MCR1109 1MCR1109G 3.25 3.25 3" X 21/2" . IMCR1110 1MCR111OG 3.29 3.29 4" X 1 1/2" 1MCR1208 1MCR1208G 4.90 4.90 4" X 2" 1MCR1209 ; 1MCR1209G ' 5.10 5.10 4" X 2 1/2" 1MCR1210 1MCR121OG 6.55 6.55 4"X3" ' 1MCR1211 :1MCR1211G 4.04 4.04 I JTEI!fIc1DD.E 1LIJIMENSIDNil 1TEM SIZE JL JLwELIJ 1/2" 1MFF04 1MFF04G 3.50 2.50 , 0.56 3/4" 1MFF05 1MFF05G 3.50 2.50 0.60 1MFF06 , 1MFF06G 4.00 3.0 0.84 1 1/4" 1MFF07 1MFF07G 4.00 3.00 0.90 11/2" IMFF08 1MFF08G 4.50 3.50 1.20 1MFF09 IMFF09G 5.50 4.25 2.03 LISTED Description I I Malleable Reducing Coupling tF- Description I I Malleable Floor Flange B .... _A LISTED www.sigmaco.com Malleable Threaded Fitt Description I FWOV SIZE I ITEM CODE II ITEM Malleable Plug 3/8" 1MPLGO3 1MPLG03G 0.06 1/2" 1MPLG04 1MPLG04G 0.10 3/4" 1MPLG05 1MPLG05G 0.17 1MPLG06 1MPLG06G 0.28 1 1/4" 1MPLG07 :. 1MPLG07G 0.44 1 1/2" 1MPLG08 1MPLG08G 0.62 1MPLG09 1MPLG09G 0.91 1 Ui 2 1/2" 1MPLG10 1MPLG10G 1.05 LISTED 3" 1MPLG11 1MPLG11G 1.70 1MPLG12 1MPLG12G 300 Description I. I 1 1 ITEME II ITEM LAcKJL_GALV__J[gjj[j NOMS1ZE Malleable Bushings L ..__JL 1/2" X 1/4" 1MBSH0402 I IMBSH0402G 0.06 1/2" X 3/8" 1MBSH0403 1MBSH0403G 0.05 3/4" X 1/2" : 1MBSH0504 1MBSH0504G 0.11 1" X 1/2" 1MBSH0604 1MBSH0604G 0.21 L " l X 3/4" 1MBSHO6O5 1MBSHO6O5G 0.17 1 1/4" X 1/2" 1MBSH0704 1MBSH0704G 0.34 1 1/4 X 3/4 1MBSH0705 1MBSH0705G 0.31 W 1 1/4" X 1" --q LISTED 1 1/2" X 3/4" 1MBSH0706 1MBSH0706G 0.26 Ui. 1 1/2 X 1/2 1MBSH0804 1MBSH0804G 0.48 I - 1MBSH0805 1MBSH0805G 0.48 - 1 1/2" X 1" 1MBSH0806 1MBSH0806G . 0.43 1 1/2" X 1 1/4" 1MBSH0807 1MBSH0807G 0.30 2" X 1/2" 1MBSH0904 1MBSH0904G .. 0.65 2" X 3/4" 1MBSH0905 1MBSH0905G 0.83 2" X 1" 1MBSH0906 1MBSH0906G 0.78 2" X 1 1/4" 1MBSH0907 1MBSH0907G 0.73 2" X 1 1/2" 1M6SH0908 .L 1MBSH0908G 0.60 2 1/2" X 1 1/4" 1MBSH1007 1MBSH1007G 1.30 21/2" X 11/2" . 1MBSH1008 1MBSH1008G 1.20 2 1/2" X 2" 1MBSH1009 1MBSH1009G 0.90 3" X 1 1/4" . 1MBSH1107 1MBSH1107G 2.50 3" X 1 1/2" 1MBSH1108 1MBSH1108G 2.30 3"X2" 1MBSH1109 1MBSH1109G 2.00 3" X 2 1/2" 1MBSH1110 1MBSH111OG 1.60 4" X 1 1/4" 1MBSH1207 1MBSH1207G 3.20 4" X 1 1/2" 1MBSH1208 1MBSH1208G 3.30 4" X2" 1MBSH1209 1MBSH1209G 3.10 4"X2 1/2" 1MBSH1210 1MBSH1210G 3.80 4" x 3" 1MBSH1211 1MBSH1211G 3.00 www.sigmaco.com r ED Malleable Threaded Description t I I I Fwuwt7l L .. ITEM CODE 1lUEiLI1 ITEM Malleable Union 1/4" 1MUN02 1MUN02G 1.81 0.45 A 3/8" 1MUN03 1MUN03G 1.81 0.42 - 1/2" . 1MUN04 1MUN04G 1.94 0.44 3/4" 1MUN05 1MUN05G 2.06 0.60 1 1MUN06 IMUN06G 244 091 1 1/4" 1MUN07 1MUN07G 2.63 1.45 1 1/2" 1MUN08 1MuN08G 2.75 1.69 2" 1MUN09 1MUN09G 2.94 2.46 3.63 4.95 LISTED 4" 1MUN12 1MUN12G 3.75 8.75 Description I I NUM I ITEM GDE IFDTlVL II iTEM Malleable Union w/ Brass Seat LR[ LACK JI_ Y_JL - J[W.E1FIL 1/4" ., 1MUNBS02 1MUNBS02G 1.81 0.45 A 3/8" 1MUNBS03 1MUNBS03G 1.81 0.42 1/2 1MUNBS04 1MUNBS04G 1.94 0.44 1MUNBS05 IMUNBS05G 2.06 0.60 1MUNBS06 1MUNBS06G 2.44 0.91 1 1/4" 1MUNBS07 1MUNBS07G 2.63 1.45 UL 11/2" 1MUNBS09 . 1MUNBS08 :11MUNBS08G 1MUNBS09G 2.75 2.94 1.69 2.46 1MUNBS11 1MUNBS11G 3.63 4.95 LISTED 4" 1MUNBS12 1MUNBS12G 3.75 8.75 Description 'LJ BLACK LGALVJLJLWIG1 Malleable Extension IZE 1/2" 1MEX04 1MEX04G 1.95 7.32 LISTED I www.sigmaco.com DVJWW ~Mn Thmd(@d Ffflng%, O Notice: D.I. Fittings have higher tensile strength then D.I. Threaded fittings are UL, cUL listed and Factory Mutual that of steel pipe, over tightening can cause damage approved for 500p5i servce. Dl. Per ASTM A 536 grade 6545- to pipe threads which may cause leakage. D.I. Fitting 12. Dimensions conform to ANSI 1316.3 Class 150. Threads are should be tightened three turns beyound hand tighten, NPT per ANSI/ASME B1.20.1 no more than four turns. Description I D. 1. 90 Degreed Elbow I I 7 __ l NOM SIZE IlTEM COUE1F 1iEMENS1Ol11 ITEM L - LkAJLJL!J&ELW1 1D90B0606 1.50 1.50 0.62 1 1/4" - 1D90130707 1.75 - 1.75 0.90 11/2" 1090B0808 1.94 1.94 1.20 1D90B0909 2.25 2.25 1.85 Description I I D. 1. Straight Teel 1 A A B flr' 1-ia c®us LISTED M SIZE I 1llTM CQPI03IMENSIQff1 ITEM LJ [ BLACKJ L JL I 1 1D1060606 1.50 1.50 0.85 1 1/4" 1DT070707 1.75 1.75 1.22 1 1/2 - 10T080808 1.94 L 1.94 1.55. 2" 1DT090909 2.25 2.25 2.45 Description I D.I. Coupling I 1 rN 5®IS WTED A 'L1. I ILTEM COIYEII U1M I FEM I LNOM SIZE L--J LE11L 1DCP0606 1.50 0.85 11/4" 1DCP0707 1.75 1.22 1 1/2" 1DCP0808 :. 1.94 1.55 1DCP0909 2.25 2.45 Description I D.I. Red .9oDeg.Elbow l I c(D LWO ST NOMSI IlITEM CODEI[DIMENSIflW ITEM LZEJLCjL AlL B J I X11/2" 1D90R0604 1.26 1.36 0.44 1 X3/4" 1D90R0605 1.37 1.45 0.52 I 1/4X 1/2" .. 1D90R0704 1.34 : 1.53 0.64 1 1/4 X 3/4" 1D90R0705 1.45 1.62 0.72 1 1/4" X 1" . 1D90R0706. 1.58 1.67 0.75 1 1/2" X 1" 1D90R0806 1.65 1.80 0.92 1 1/2" X 11/4". 1D90R0807 1.82 1.88 1.08 2" X1/2" 1090R0904 1.49 1.88 1.08 2" X 3/4". 1D90R0905 1.60 1.97 1.24 2" X 1" 1D90R0906 1.73 2.02 1.40 2" X11/4" .. 1D90R0907: 1.90 2.10 1.52 2" x 1/2" 1D90R0908 2.02 2.16 1.65 Description I 1 D. Reducing Coupling I I LNOM FTIIMTII ITEIVF1 SJ BLACj 7ELQH31 C®US UMD 1 X 1/2" . 1DCR0604 1.69 0.39 1 X 3/4" IDCR0605 1.69 0.53 Description I I D.I. 45 Degreed Elbow F 1 ILTEM CEIEEJ1MENSIN][1TEM NOM SIZE LAK]I A II B 1AF.LG1-I11 1D45130606 1.12 1.12 0.46 1 1/4" 1D45B0707 1.29 1.29 0.73 1 1/2" . 1D45130808 1.43 1.43 0.92 1D45B0909 1.68 1.68 1.50 www.sigmaco.com Ductile Iron Threaded Description L I DI. Bushing I I B B IA ZI LISTED OUTSIDE HEAD INSIDE HEAD vJ FM- IITEM CODE] IDIMENSIGNI] liii IW L!I]rc -]r] 1 X112" 1DBUS0604 0.750.251.42 OUT 0.22 1 X314" 1DBUS0605 0.75 0.25 1.42 OUT 0.17 1 1/4 X 1 1DBUS0706 080 0.28 1.76 OUT 1.28 1 1/2" X 1" 1DBUS0806 0.83 " 0.3l ..2.00 OUT .. 0.44 1 1/2 Xl 1/4 1DBUS0807 0.83 031 200 OUT 0.30 2" X 1" 1DBUSO906 0.88 0.41 1.95 IN 0.66 2" X1 1/4" 1DBUS0907 0.884 0.34 2.48 OUT 0.72 2" X 1 1/2" 1DBUS0908 0.88 0.34 2.48 OUT 0.61 Description D. 1. Cross I CD flED LISTED F~MI IMENS1ON1I ITEM I SIZEjLBcKjL [D AJL 13 JiEicift1i 1DX0606 1.50 J 1.50 0.98 1 1/4" 1DX0707 1.75 1.75 1.50 1 1/2" 1DX0808 1.94 1.94 1.90 1DX0909 2.25 2.25 2.95 1 1/4" X 1" 1DX0706 1.58 1.67 1.27 11/2" X 1" 1 DX0806 1.65 1.80 1.45 2"X 1" 1DX0906 1.73 2.02 2.10 Description I D.I. Cap l IA LISTED 1c 1I 1MM. IrITEM[_~OM~17Z]E [ BLACK ILjEJH11 1DK06 1.16 0.32 1 1/4" 1DK07 1.28 0.43 1 1/2" 1DK08 1.33 0.60 1DK09 1.45 0.91 www.sigmaco.com Description I I D.I. Reducing Tee F GEBA or"LEM NOM SIZE ill M0DE1E DIMENSiON 11 ITEM L_ 1[.1L1L .CJJ lx 1"x 1/2" 1DT060604 1.26 1.26 1.36 0.64 1" xi" x3/4" 10T060605 1.37 1.37 1.45 0.73 I x 1/2 x 1 1DT060406 1.50 1.36 1.50 0.71 1" x 3/4" x1" 1D1060506 1.50 1.45 1.50 0.76 lx lxi 1/4" 1DT060607 1.67 1.67 ' 1.58 0.98 1" xl" x 1/2" 1DT060608 1.80 1.80 1.65 1.16 1 1/4 x 1 x 1/2 1D1070604 1.34 1.26 1.53 082 11/4" xix 3/4" 1DT070605 1.45 1.37 1.62 0.90 11/4"x 1" xl" lDT070606 1.58 1.50 1.67 1.00 11/4" x 1" x 1 1/4" 1DT070607 1.75 1.67 1.75 1.08 1 1/4 x 1 x 1 1/2 lDT070608 1.88 1.88 1.82 1.42 11/4" xi 1/4"x1/2" 1DT070704 1.34 1.34 1.53 0.86 11/4" xi 1/4"x3/4" 10T070705 1.45 1.45 1.62 0.92 11/4" x 11/4" x 1" 1DT070706 1.58 1.58 1.67 0.95 1 1/4 x 1 1/4x 1 10T070708 1.88 1.88 1.62 1.45 1 1/4"x1 1/4"x2" 1DT070709 2.10 2.10 1.90 1.75 1 112"x 1"x 1/2" 1DT080604 1.41 1.34 1.66 0.95 11/2" x 1" x 3/4" 1DT080605 1.52 1.37 1.75 1.14 1 1/2"x l"x i' 1DT080606 1.65 1.50 1.80 1.17 11/2" x 1" x 11/4" 10T080607 1.82 1.67 1.88 1.34 1 1/2 x 1 x 1 1/2 1DT080608 1.94 1.80 194 1.45 11/2" x 11/4" x 1/2" 1DT080704 1.41 1.34 1.66 1.05 1 1/2 x 1 1/4 x 3/4 1D1080705 1.52 1.45 1.75 115 1 1/2"x 11/4" xi" 1DT080706 1.65 1.58 1.80 1.25 11/2 x 1/4 x2 1DT080709 216 210 202 190 11/2" x 1/2" x 1/2" 1D1080804 1.41 1.41 1.16 1.15 11/2" x 1 1/2" x 3/4" iDT080805 1.52 1.52 1.75 ' 1.24 11/2" x 11/2" x 1" iDT080806 1.65 1.65 1.80 1.30 1 1/2 x 1 1/2 x 1 1DT080807 1.82 1.82 1.88 1.48 11/2" x 1/2" x2" iDT080809 2.16 2.16 2.02 1.98 2 x 1 x 2 1 DT090609 2'.25 2.02 2.25 2.15 2" x 1 1/4" x 2" 1DT090709 2.25 2.10 2.25 2.30 2 x 1 1/2 x 1/2 1DT090804 1.49 1.41 1.88 1.50 2"x1 1/2"x3/4" 1DT090805 1.60 1.52 1.97 1.62 2" xi 1/2" xi" : 1DT090806 1.73 1.65 2.02 1.64 2"x i 1/2"x 11/4" iDT090807 1.90 1.82 2.10 1.80 2" x i 1/2" x 1 1/2" 1D1090808 2.02 1.94 2.16 2.00 2" x 1 1/2" x 2" 1D1090809 2.25 2.16 2.25 2.35 2" x 2" x 1/2" 1DT090904 1.49 1.49 1.88 1.60 2" x 2" x 3/4" 1 DT090905 1.60 1.60 1.97 1.68 2"x2"x1" lDT090906 1.73 1.73 2.02 1.85 2" x2" x 1/4" 1D1090907 1.90 1.90 2.10 2.04 2" x 2" x 1 1/2" 1DT090908 2.02 2.02 2.16 2.18 2" x 2" x 2 1/2" 1DT090910 2.60 2.60 2.39 3.61 2 112"x2"x3/4" lDT100905 1.74 1.60 2.32 2.28 C9W BMn ThmdW Ffflngo O C.I. Threaded fittings are UL, cUL listed and Factory Mutual approved for 300psi servce. Gray iron per ASTM 126 class B. Dimensions conform to ANSI B 16.4 Class 125 except plugs conform toASME B 16,14. Threads are NPT perANSI/ASME 131.20.1. Description [ I C.I. 90 Degreed Elbow I I B c LISTED os M SIZE IJTENrcOUE1I DIMENSIUNJI ITEM L LL1.iIEiH 1" 1C90B0606 1.50 1.50 0.85 11/4" 1 C90B0707 1.75 1.75 1.22 1 1!2" 1C90Bo808 1.94 :r. 1.94 1.55 2" 1C90B0909 2.25 2.25 2.45 2 1/2" 1C90B1010J 2.70 , 2.70 4.80 Description I I C.I. Straight Tee A A -@U3 ! LN 1UTEMQ1FIThMENSEN1 ITEM OMSIZEJL BLAc!cjL_1L J 1CT060606 1.50 1.50 0.85 11/4" 1CT070707 1.75 1.75 1.22 1 1/2 1C1080808 1.94 1.94 1.55 1CT090909 2.25 2.25 2.45 21/2 1CT1O1010 270 270 639 Description I I C.I. Reducing Coupling I I NOM SIZE 1llTMt1E1I I TMJ IM ][ arLp&rcJ[ A IWtnd TE 1 X 1/2" 1CCR0604 1.69 0.62 1 X 3/4" 1CCR0605 1.69 0.69 Description L - C.I. Reducing i 1 90 Degreed Elbow i /f7 T1L FNOM SIZE ME= FTTEM7 1 X1/2" 1C90R0604 1.26 1.36 0.44 1 X 3/4" 11390R0605 1.37 1.45 0.52 1 1/4 X 1/2" tC90R0704 1.34 1.53 0.64 1 1/4 X 314" 1C90R0705 1.45 1.62 0.72 1 1/4" X 1" 1C90R0706 1.58 1.67 0.75 . 1 112"X1/2" 11390R0804 1.60 1.70 1.17 11/2" X 3/4" 1C90R0805, 1.61 1.72 : 1.30 1 1/2"X 1" - 1C90R0806 1.65 1.80 0.92 11/2" X I 1I4't 1C90R0807 1.82 1.88 1.08 2" X 1/2" 1C90R0904 1.49 1.88 1.08 2"X3/4" 1C90R0905 1.60 1.97 1.24 2"X 1" _,. 1C90R0906 1.73 2.02 1.40 2" Xl 1/4" •. 1C90R0907 1.90 ' 2.10 1.52 2" X 1 1/2" 1C90R0908 2.02 2.16 1.65 Description L C.I. 45 Degreed Elbow I I I NOM SIZE UTM CIYEEILDIMENSIONJ ITEM AJLJL!1] 1C45B0606 1.12 1.12 0.46 1 1/4" 1C45B0707 1.29 1.29 0.73 1 1/2" 1C45B0808 1.43 1.43 0.92 1C45B0909 1.68 1.68 1.50 www.sigmaco.com Cast Iron Threaded Fittin Description I I C. 1. Reducing Tee'_____________________ A ___ B USTM NOM L!! llTEMGDEII DIMENSION .11 ITEM LJL JL?I1LJJFt 1" x lx 1/2' 1CT060604 1.26 1.26 1.36 0.95 1" x 1" x 3/4" 1CT060605 1.37 1.37 1.45 1.10 1" x 1/2" x1" 1C1060406 1.50 1.36 1.50 1.08 x 3/4" xl" - 1C1060506 1.50 1.45 1.50 1.18 1"x1"x11/4" 1CT0606O7 1.67:1.67 1.58 1.52 lx 1" x 1 1/2" 1CT060608 1.80 1.80 1.65 1.73 1 1/4 x 1 x 1/2 1CT070604 1.34 1.26 1.53 117 11/4" x 1" x 3/4" 1CT070605 1.45 1.37 1.62 1.38 1 1/4"x 1"x 1" 1CT070606 1.58 1.50 1.57 1.47 11/4" x 1" x 1/4" 1C1070607 1.75 1.67 1.75 1.80 11/4" x 1" x 11/2" 1C1070608 :. 1.88 1.80 1.82 2.05 11/4" x 11/4" x 1/2" 1CT070704 1.34 1.34 1.53 1.37 I 1/4"x 1 1/4"x3/4" 1C1070705 1.45 1.45 1.62 1.54 1 1/4"x 11/4" x 1" 1C1070706 1.58 1.58 1.67 1.65 1 1/4 x 1 1/4 x 1/2 1C1070708 1.88 1.88 1.82 2.21 11/4" x 1/4"x2" 1C1070709 2.10 2.10 1.90 2.55 11/2" x " x 1/2" 161080604 1.41 1.34 1.66 1.41 11/2" x 1" x 3/4" 1CT080605 1.52 1.37 1.75 1.65 1 1/2 x 1 x 1 1C1080606 1.65 1.50 1.80 1.65 11/2" x 1" x 1/4" 1CT080607 1.82 1.67 1.88 2.00 1 1/2 x 1 x 1 1/2 1CT080608 1.94 1.80 1.94 2.30 1 1/2"x 11/4" x 1/2" 1CT080704 1.41 1.34 1.66 1.58 1/2 x 1/4 x 3/4 1CT080705 152 145 175 1.72 11/2" x 11/4" x 1" 1C1080706 1.65 1.58 1.80 1.85 11/2 x 11/4 x 1/4 1C1080707 1.82 1.75 1.88 2.22 1 1/2"x1 1/4"x1 1/2" 1CT080708 1.94 1.88 1.94 2.45- 1 1/2 x11/4 x2 1C1080709 1 216 210 202 280 11/2" x 11/2" x 1/2" lCT080804 1.41 1.41 1.66 1.76 11/2 x11/2 x3/4 1CT080805 152 152 175 187 11/2" x 11/2" x 1" 1CT080806 1.65 1.65 1.80 1.94 11/2"x1 1/2"x1 1/4"1CT080807 1.82 1.82 1.88 2:29 1 1/2" x 1 1/2" x 2" 1CT080809 2.16 2.16 2.02 3.28 2"x1" x2" 1CT090609 2.25 ' 2.02 2.25 3:40 x 1 1/4" x 2" 1CT090709 2.25 2.10 2.25 2.80 2" x 1 1/2"x 1/2" 1C1090804 1.49 1.41 = 1.88 2.09 2" x 1 1/2" x 3/4" 1CT090805 1.60 1.52 1.97 2.40 2" x 1/2" x " 1CT090806 1.73 1.65 2.02 2.54 2" x 1 1/2" x 1 1/4" 1CT090807 1.90 1.82 2.10 2.85 2" x 11/2" x 11/2" 1CT090808 1.49 1.41 1.88 .. 224 2" x 1 1/2" x 2" 1C1090809 2.25 2.16 2.25 3.75 2"x2" x 1/2" 1CT090904 1.49 1.49 1.88 2.60 2" x 2" x 3/4" 1C1090905 1.60 1:60 1.97 2.71 2" x 2" x1" 1C1090906 1.73 1.73 2.02 2.97 2" x 2" x 1 1/4" 1CT090907 1.90 1.90 2.10 3.32 2" x 2" x 1112" 1CT090908 2.02 2.02 2.16 3.72 2" x 2" x 2 1/2" 1CT090910 2.60 2.60 2.39 5.10 www.sigmaco.com Description I 0.1. Plugs ceus KOM A LLUM NOM SIZE IITEM OII flIM 1flTEM 1/2" ., 1CPLG0404 0.94 0.10 3/4" 1CPLG0505 1.07 0.17 1 CPLG0606 1.25 0.28 1 1/4" 1CPLG0707 1.36 0.44 1 1/2" =. 1CPLG0808 :. 1.45 0.62 1CPLG0909 1.56 0.91 Description 1 1 0.1. Cross I I A A F~~ SIZ Ill EM COD1I DIMENSION II ITEM LcJcJL JLQJNELH]1 1CX0606 1.50 1.50 1.54 1 1/4" 1CX0707 1.75 1.75 2.40 1 1/2 1CX0808 1.94 1.94 3.10 1CX0909 2.25 2.25 4.00 1 1/4 X 1 1CX0706 1.58 1 1.67 2.05 1 1/2" X 1" 1CX0806 1.65 1.80 2.40 2" X 1" 1 CX0906 = 1.73 2.02 2.75 FLENGTHF2 I NOMINAL SIZE l'iLA' J[ iLJL 6" I CLOSE 1NB1001 1NB1101 V 1NB1201 1NB1401 1NB1011 1NB1111 NA NA 31/2 1NB1011 5 1NB1111 5 1NB1211 5 NA - 1NB1012 1NB1112 1NB1212 NA 41/2" HNB1012-51. 1NB1112-5 1NB1212-5 NA 51, - 1NB1013 1NB1113 - 1NB1213 NA - 5 1/2" 1NB1013-5 1NB1I13-5 1 NB. 1213-5 NA 1NB1014 1NB1114 1NB1214 1NB1414 V 1NB1015 1NB1115 1NB1215 V 1NB1415 1NB1016 1NB1116 1NB1216 1NB1416 IT 1NB1017 1NB1117 V 1NB1217 1NB1417 V 1NB1018 1NB1118 1NB1218 1NB1418 1NB1019 1NB1119 1NB1219 1NB1419 V www.sigmaco.com DMMn PJP Mpo(MB Mad~ O Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME B1.20.1 Description I Black Steel FLEN —iNOMINALSIZETH 11141L1112" L J CLOSE 1NB010I 1NB0201 .. INB0301 1NB0401 1NB0501 1NB0601 INBO701 1NB0801 1NB0901 11/2" 1NBO108 1NB0208 1NB0308 1NB0408 1NB0508 NA NA NA NA 2" 1NBO109 1NB0209 1NB0309 1NB0409 1NB0509 1N80609 1NB0709 .. 1NB0809 NA 2 1/2" 1NBO110 1NB02010 1NBO310 1NB0410 1NBO510 1NB0610 1NB0710 1NBO810 1NB0910 1 1NBO111 1NB0211 1NB0311 1NB0411 1NBO51I 1NB0611 '' 1NBO711 1NB0811 1NB0911 3 1/2" 1NBO111-5 1NB0211-5 1NBO311-5 1NB0411-5 1NB0511-5 1NB0611-5 1NB0711-5 1NBO811-5 1NB0911-5 4" i1NB0112 1NB0212 1NB0312 1NB0412 1NBO512' 1N80612 1NB0712 . 1NB0812 1NB0912 4 1/2" 1NBO112-5 1NB0212-5 1NB0312-5 1NB0412-5 1NB0512-5 1NB0612-5 * 1NB0712-5 1NB0812-5 1NB0912-5 5" 1NBO113 .. 1NB0213 1NB0313 1NB0413 1NB0513 1NB0613 1NB07.13 , 1N80813 1NB0913 5 1/2" - 1NBO113-5 1NB0213-5 1NB0313-5 1N80413-5 1NB0513-5 1NB0613-5 1NB0713-5 1NB0813-5 1NB0913-5 6" 1NBO114 1NB0214 1NB0314 1NB0414 1NB0514 1NB0614 1NB0714 . 1NB0814 IN B0914 61/?" 1NBO114-51NB0214-5 1NB0314-5 1N80414-5 V 1NB0514-5 1NB0614-5 1NB0714-51NB0814-5 1NB0914-5 V NA ..: NA NA NA NA 1NB06147 V 1N807147 .tN08147 V 71/2" NA NA NA NA NA 1NB06147-5 1NB07147-51N808147-5 1NB09147-5 V 1NB0115 V 1NB0215 1NB0315 1NB0415 1NB0515 1NB0615 1NB0715 VV 1NB0815 1NB0915 81/2" V NA NA NA V NA NA 1NB0615-5 _1NB071-5 1NB0815-5 1NB0915-5 1NBO116 1NB0216 1NB0316 1NB0416 V V 1NB0516 1NB0616 1NB0716 V 1NB0816 1NB0916 91/2" , NA _. NA V.N. NA NA 1NB0616 -5 1NB0716-5 i!4BP16-5 1NB0916-5 101, 1N60117 1NB0217 1NB0317 V 1NB0417 V 1NB0517 V V 1NB0617 1NB0717 V 1N60817 V 1NB0917 V 10 1/2" NA NA NA NA NA 1NB0617-5 1NB0717-5 1NB0817-5 1NB0917-5 V 1NB0118 1NB0218 1NB0318 1NB0418 1NB0518 1NB0618 1NB0718 V 1NB0818 1NB0918 111/2" - * NA V NA NA * NA NA 1NB0618-5 1NB0718-51NB0818-5 1NB0918-5 12" 1NB0119..1NB0219 .1NB0319 1NB0419 1NB0519 ,V1NB0619 .V 1NB0719 ,.1NB0819 .1NBO919 UMPOA Li© MOPWS Gallwank(gd O Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME 131.20.1 Galvanized to spec. ASTMA 153- for zinc coating. Description [ Galvanized Steel' P NOMINALSIZE J[ 1/2" IL JLi1.'4' IL1i!"i 11/2" CLOSE 1NG0101 1NGO201 1NG0301 ING0401 1NG0501 1NG0601 1NG0701 1NG0801 1NGO9O1 1" NA 1NGO2O1-1 NA NA NA NA NA NA NA 11/4 NA i NA NA NA NA NA NA NA NA 11/2' 1NG0108 1NG0208 1NG0308 1NG0408 1NG0508 NA NA - NA NA 2 1NG0109 1NG0209 1NG0309 1NG0409 1NG0509 1NG0609 1NG0709 1NG080. NA 21/2" 1NG01I0 1NG02010 1NG0310 1NG0410 1NG0510 1NG0610 1NG0710 1NG0810 1NG0910 3 1NG0111 1NG0211 1NG0311 1NG0411 1NG0511 ING0611 1NG0711 1NG0811 1NG0911 3 1/2" 1NG0111-5 ING0211-5 1NG0311-5 1NGO4I1-5 ING05I1-5 1NG0611-5 1NG0711-5 ING08II-5 ING09I1-5 4 1NG0112 1NG0212 1NG0312 1NG0412 1NG0512 1NG0612 1NG0712 1NG0812 1NG0912 4 1/2" 1NG0112-5 1NG0212-5 1NG0312-5 1NG0412-5 1NG0512-5 1NG0612-5 1NG0712-5 1NG0812-5 1NG0912-5 5 1NG0113 1NG0213 1NG0313 1NG0413 1NG0513 1NG0613 1NG0713 1NG0813 1NG0913 5 1/2" 1NG0113-5 1NG0213-5 1NG0313-5 1NG0413-5 1NG0513-5 1NG0613-5 1NG0713-5 1NG0813-5 1NG0913-5 6 1NG0114 1NG0214 1NG0314 1NG0414 1NG0514 1NG0614 1NG0714 1NG0814 1NG0914 6 1/2" 1NG0114-5 1NG0214-5 1NG0314-5 1NG0414-5 1NG0514-5 1NG0614-5 1NG0714-5 1NG0814-5 1NG0914-5 7 NA NA NA 1NG04147 NA 1NG06147 1NG07147 1NG08147 1NG09147 8" 1NG0115 1NG0215 1NG0315 1NG0415 1NG0515 1NG0615 1NG0715 1NG0815 1NG0915 8 1/2 NA NA NA 1NG04155 NA NA NA NA - NA 9" 1NG0116 - 1NG0216 1NG0316 1NG0416 1NG0516 1NG0616 1NG0716 1NG0816 1NG0916 10"4 1NG0117 1NG0217 1NG0317 1NG0417 1NG0517 1NG0617 1NG0717 1NG0817 1NG0917 1NG0118 1NG0218 1NG0318 1NG0418 1NG0518 1NG0618 1NG0718 1NG0818 1NG0918 1NG0119 1NG0219 ' 1NG0319 1NG0419 1NG0519 1NG0619 1NG0719 1NG0819 1NG0919 l[ NOMINAL SIZE I LENGTH L - -- JL flI2_".J LL CLOSE 1NG1001 1NG1101 1NG1201 1NG1401 1NG1011 1NG1111 NA NA 31/2 1NG1011 5 1NG1111 5 NA NA 1NGI012 1NG1112 1NG1212 NA 4 1/2 1NG1012 5 1NG1112 5 1NG1212 5 NA 1NG1013 1NG1113 1NG1213 NA 51/2 1NG1013 5 1NG1113 5 1NG1213 5 NA 1NG1014 1NG1114 1NG1214 1NG1414 7 NA 1NG11145 NA NA 1NG1O15 1NG1115 1NG1215 1NG1415 - INGI016 1NGI116 iNG1216 1NG1416 . 1NG1017 1NG1117 1NG1217 1NG1417 1NG1018 1NG1118 1NG1218 . 1NG1418 1 12" 1NG1019 1NG1119 1NG1219 1NG1419 www.sigmaco.com IUIEA(~~H&HcT ODUFUH00 Eli Manufactured from carbon steel (which conforms to ASTM A 865 standard) EJThreads conform to ASME 13I.20.1 standards for pipe threads. 0 Sizes 2' and below are straight tapped and 2 1/2" and above are tapper tapped. Description I -- I Size Item Code D L 1/2" 1 MCC0404 1.063" 1.563" 3/4" 1MCC0505 1.31Y 1625" 1MCC0606 1.576" 2.00" 1-1/4" IMCCO7O7 1.900" 2.063" 1-1/2" 1MCC0808 2.200" 2.063" 1MCC0909 2.750" 2.125" 2-1/2" 1MCC1010 3.250" 3 125" 1MCC1111 4.00" 3.250" 1MCCI2I2 5.00" 3.500" L www.sigmaco.com victaulic.com I FireLockW Fittings I Publication 10.03 Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' No. 002 Nominal Outside Size Diameter Elbows Straight Tee No. 001 No. 003 inches inches mm mm 90° Elbow 45° Elbow Branch Run 1¼ 1.660 - - - - 32 42.4 - - - - 1½ 1.900 - - - - 40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7 mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 I The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the 'QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Reference should always be made to the 1-100 Victaulic Field lnstu/ation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaolic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic° is registered trademark of Victaulic Company. 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 'j'tauIic Patent #5,344,108 Approx. Wt/100 Part No. lbs. (kg) 25 4.8 (2.2) Pipe Clamps TOLCOTM Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4 (20mm) thru 2' (40mm) pipe. 9@6t Material: - Pre-Galvanized Steel LISTED Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized 0010/ Order By: Part number and band hanger, size from 3/4" (20mm) thru 2" (40mm). All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 99 B-Line series Pipe Hangers & Supports Beam Clamps TOLCOTM Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening TOLCOTM Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: Fig. 65 - 1/2".13 rod sizes, and 5/8"-11 rod sizes Fig. 65XT - I8"-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /8'-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2"..13 rod will support 1/2" (15mm) thru 8" (200mm) pipe Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Part number and finish Fig. 65 Patent #4,570,885 Part F Mac Rec. Load * Approx. Wt./100 No. in. (mm) lbs. (kN) lbs. (kg) 65-1/2 11/4" (31.7) 1130 (5.02) 55 (24.9) 65-/8 11/4" (31.7) 1130 (5.02) 55 (24.9) * Maximum loads for clamp with set screw in up or down position. Note: See page 27 for recommended setscrew torque. Fig. 65XT-3/8 - Beam Clamp C&S zf3 Feature: Extruded holes allow for more thread LISTED engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Design Load: 730 Lbs )3.25kN( Finish: Plain or E)ectro-Ga Ivan ized . Order By: Part number and finish - Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering Approved (FM) for up to 4" (100mm) pipe. Note: See page 27 for recommended setscrew torque. Component of State of California OSHPD Approved Seismic Restraints System c®Us LISTED Set Screw and Locknut Included 3/4' (19.0) Set Screw and 1/9'1 Locknut Included 1/8" 122.21 (34.9) Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65_1/2 1/2"_13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-5/8 /8"-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) Al) dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 33 B-Line series Pipe Hangers & Supports Component of State of c Vi. California OSHPD Approved LISTED Seismic Restraints System A-A Beam Clamps TOLCOTM Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: I8'-16 & 1/2'..13 rod 4" (101,6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as a hex nut or the beveled locking slot of the Fig. 69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Pre-Galvanized Order By: Part number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) * Patent #5,947,424 Slot Width For Use With Length Part No. in. (mm) B3O33-/8, B3034-3/8, 133031-3/8, 69R-3/8-L /16" 111.11 Specify 65-/8, 65X1-3/8, 66-/ 69R-1/2-L /16" (14.3) B3033-1/2, 133034-1 /2, 65-1/2, 66-1I2 Specify All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports 38 Eaton Component of State of California OSHPD Approved Seismic Restraints System . 98 - Rod Stiffener Fi%98B - Rod Stiffener w/Break-off Bolt Head Size RangëSecures 3/8' thru 7/8" hanger rod Material - Ca'% re Function - Snel to hanger rod for vertical seismic bracing. Approvals - our Seismic Restraints Catalog aroved FIG. 98 Finish - Electro Galvanized Note - Available in HDG finish or Stainless materials. Order By - Figure number FIG. 98B Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Max. Rec. Load Lbs. S& For Service Temp 650°F 3/8 730 1/2 N14, 1350 3/4 7/8 Size Range - Secures 3/8" thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100 - All Thread Rod Full Lnnth Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwtolco.com c®uS <E> LISTED Set Screw Included Mounting Hardware Is Not Included 98( K 980H All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers & Supports 182 B-Line by 14'j Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - /8"-16 to I411-10 rods Component of State of California OSHPD Approved Fig. 980H - Universal Swivel Sway Brace Attachment - 7/11_9 to 11/4"7 rods Seismic Restraints System Size Range: One size fits bracing pipe 1(25mm) thru 2" (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/40 (31 .7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the bracing pipe and TOLCO braced pipe attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 980 onto the bracing pipe. Tighten the set screw until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note: Fig. 980 Swivel Attachment and Fig. 1001, Fig. 1000, Fig. 2002, Fig. 4A, Fig. 4B or Fig. 4L pipe clamps make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. US Patent Numbers Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Approx rue .B . fiD*Z. TLoad (cULus)5' l30° 044O 15°59° ° 4 75° 90 t7/100 Irnjiw rni • 'I 2550 ______ IllIiui * Mounting attachment hole size. ** Installed with 1" or 11/4" Schedule 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. TOLCOTM Seismic Bracing Set Scre In Fig. 41 - Longitudinal "In-Line" Sway Brace Attachment Size Range: 2" (50mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 21/2" (65mm) through 8" (200mm) pipe. Approved by Factory Mutual Engineering (FM), 2" (50mm) through 8" (200mm) pipe. Installation Instructions: Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set screw until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. 4Way ;aR::v ace C®uS <> LISTED 41-2 (50) 5/8" (136.5) 21/16" (52.4) 21/16" (52.4) 1/2"13 2015 (8.96) -- (--) 247 (112.0) 4L-21/2 21/2 (65) 6/16" (163.5) 21/2" (63.5) 2/4" (69.8) 1/2"_13 2015 (8.96) 3000 (13.34) 253 (114.7) 41-3 (80) (177.8) 2I4" (69.8) 31/16" (77.8) 1/2"13 2015 (8.96) 1550 (6.89) 268 (121.5) 41-4 (100) 81/2" (215.9) 3I8" (85.7) 311/16" (93.7) 1/2"..13 2015 (8.96) 1550 (6.89) 348 (157.8) 41-5 (125) 93/4" (247.6) 3/8" (98.4) 4 /8" (111.1) 1/2"_13 2015 (8.96) 1450 (6.45) 380 (172.3) 41-6 (150) 111/2" (292.1) 5' (127.0) 51/8" (130.2) 1/2"..13 1 2015 (8.96) 1 1450 (6.45) 1 640 (290.3) 41-8 (200) 131/4" (336.5) 5/8" (142.8) 5I8" 1 (142.9) 1/2"..13 1 2015 (8.96) 1 1450 1 (6.45) 1 728 (330.2) J . 4L-2 (50) 2015 (8.96) -- -- -- -- 41_21/2 21/2' (65) 2015 (8.96) 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 41-3 (80) 2015 (8.96) 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 41-4 (100) 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-5 (125) 2015 (8.96) 530 (2.36) 730 (3.25) 1 890 (3.96) 990 (4.40) 4L-6 (150) 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 4L-8 8" (200) 2015 (8.96) 490 (2.18) 680 (3.02) 830 (3.69) 930 (4.13) * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? the installation angle measured from the vertical. FM approved when used with 1", 1/4", 11/2" or 2" Sch. 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers & Supports 170 by '4 ®us LISTED crews Included Pipe Max. Horizontal Design Load (UL) - Lbs. Size For Brace Pipe Size 1" I 11/4" Sch. 1 Sch. 10 Sch. 40 in. (mm) l"/1'/4" 1"I11I4 1-/11/4- 11" (25) --I -- 1000 /1000 1000 /1000 11/4" (32) 1000/1000 1000/1000 1000/1000 1 1/2" (40) 1000/1000 1500/1500 1500/1500 (50) 1000/1000 2015/2015 2015/2015 21/2" 1651 1600/1600 2015/2165 2015/2765 (80) 1600/1600 2015/2765 2015/2765 (100) 1600/1600 2015/2765 2015/2765 6" (150) 1600/1600 2015/2765 2015/2765 8" (200) 1600/1600 2015/2165 2015/2765 Seismic Bracing TOLCO Fig. 1001 - Sway Brace Attachment California Component of State of OSHPD Approved Seismic Restraints System Size Range: Pipe size to be braced: 1(25mm) thru 8' (200mm) IPS. * Pipe size used for bracing: 1' (25mm) and 11/4'132mm1 Schedule 40 IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set screws until heads bottom out. A minimum of 1' (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA and Canada (cULus). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines, OPA-0300-10. Finish: Plain or Electro-Ga Ivan ized. Contact customer service for alternative finishes and materials. Order By: Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. Part Number & Approx. Wt./100 Max. Horizontal Design Load (FM) Pipe For Sch. 1, Sch. 10, & Sch. 40 Pipe 1.3 Size 1" (24mm) Brace Pipe 11I4" (32mm) Brace Pipe 300-440 45°-590 600-140 150-90° in. (mm) Lbs. (kg) I Lbs. (kg) Lbs. (kNI Lbs. (kN) Lbs. (kN) Lbs. (kN) (25) 1001-1 X 100.0 (45.3) 1001-1 X 11/4 118.0 (53.5) 1800 18.001 2550 (11.34) 3120 (13.88) 3490 (25.52) 11/4" (32) 1001-11/4 X 1 100.0 (45.3) 1001-1'/4 X 11/4 114.0 (51,7) 1230 (5.47) 1140(7.74) 2140(9.52) 2380 (10.58) 11/2" (40) 1001-11/2 X 1 100.0 (45.3) 1001-11/2 X 11/4 115.0 (52.1) 1230 (5.47) 1740(7.74) 2140(9.52) 2380 (10.58) (50) 1001-2 X 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 21/2" (65) 1001-21 I2 X 138.6 (62.8) 1001_21/2 X 11/4 160.4 (72.7) 800 (3.56) 1130(5.02) 1380 (6.14) 1540 (6.85) (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11I4 168.1 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (1.29) (100) 1001-4 X 1 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 6" (150) 1001-6 X 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" 12001 1001-8 X 217.4 (98.6) 1 1001-8 X 11/4 238.8 (108.3) 1 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/T 3091,EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwa)l, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. P~:~ `~Vx T I All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 193 B-Line series Pipe Hangers & Supports SAMMWT FOR WOOD 17, Not less than 2' nominal width Not less than 3' nominal thickness (2-1/2') (depth or side of vertical member) A Wood Wood Joist Double Sheetrock Cellinq nd ailat Ntranutactsret3r e-d?iltii/'Th/iybe required for_CS/a 'No pre-drilling required, Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver, Saves time from traditional methods, Reduces installation costs. Manufactured in the U.S.A. I @.r a video denronsaeont www,ilwbuiIdex!7I) & #14 Black Nut Driver Part #8113910 A . #14 SW Red Nut Driver Part #8114910 I W#tHIs1iU?i[.1J1IV 1/4' 8002957 GST 100 1/4 x1' 25 125 GST200 1/4x2 1760 25125 3/8' 8007957 GST 10 1/4 x r 210 (7/16'OSB) 300 25 125 LQ__ 318 8008957 _T2 0 1/4x2 1760 (Fe) 850 1475 25 125] 3/8' 8068925 GST 20-SS 1/4 x 2' 1760 (Fir) 850 25 125 3t8 8009925 GST2&3803/8x21/22113(Fw) 1500 25 125 3/8' 8010957 GST30 114x3 2060 (Fir) 1500 1475 25 125 [8069925 6 ST OSS _—IL 2060 (fri --25 125 J 1/2' 8013925 GST2 1/4x2' 1760 (Fir) 25 125 1/28015925 (T ST T3 1/4x3 2275 (Fir) 25 125 ACDssAV 60'~ SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into , contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Not less than 2" nominal width (1-1/2") up to 3-1/2" pipe; not less than 3' (2-1/2"( nominal width V& 5" pipe 4 Floor Joist - No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a 4deo demonshation at www.itwbuildex.com Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams. 1/4° 8019957 SWG200 1/4x2" 1725 (Fir) 25 125 3/8 8020957 SWGIO V4x1 622v) 300 25 125 3/8° 8021957 SWG 20 1/4x 2" 1725 (Fir) 1050 25 125 [Q 3/8 8073925 - SWG 20 SS 1/4x 2 1725(Fw) 850 25 125 3/8"" 8022925 SWG25-380 3/8x2-1/2" 2249 (Fir) 1500 25 125 #14SWRed L.._. _______ 8023925 - SWG3O - 1/4x3" 1884 (Fir) _____________ 25 125 Nut Driver Part #8114910 * May require pre-drilling; consult joist manufacturer. Eliminates distortion of threaded rod. - ------ ----.zi Accommodates up to3%" X 12 pitch roof. Allows 17" deflection from vertical. -"' Saves time from traditional methods. Reduces installation costs. - Manufactured in the U.S.A. #14 Black 1Nut Driver Part#8113910 i 1903 Dim. Lumber -- 3/8"" 8269957 SH-GST/CST2O 5/16x 1-3/4' 1406@450ff vertical 1500 Dim. Lumber 903 Dim. Lumber - 1/2' 8303957 SH-GSTICST2.0 5/16x 1-3/4 1406 @ 45°off vertical 4 Dim. Lumber May require pre-drilling: consult joist manufacturer. #14 SIt Orange Nut Driver Part #8273910 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5.1 Product Description 3.3.5.1 Product Description ni w Hilti KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide Specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product Features Suitable for cracked and uncracked normal weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size and uses standard ANSI B212.15 - 1994 drill bits. Suitable for reduced edge distances and spacing. 3.3.5.2 Material Specifications Hilti KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8pm. 3.3.5.3 Technical Data The data contained in Tables 1-4 of this section have been evaluated in accordance with AC 193. For more detail, see ICC-ES ESR 3027. Figure 1 - KWIK HUS-EZ I anchor installation details —Idit I— 3.3.5.2 Material Specifications 3.3.5.3 Technical Data 3.3.5.4 Installation Instructions 3.3.5.5 Orderinq Information Listinas/AnDrovals ICC-ES (International Code Council) ESR-3027 (Cracked & Uncracked Concrete) FM Approved APPROVED Independent Code Evaluation IBC®/ lRC® 2009 (AC 193/ AC! 355.2) IBC®/ IRC® 2006 (AC 193/ ACI 355.2) IBC®/ IRC® 2003 (AC 193/ACI 355.2) 2 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 Table 1 - KWlK HUS-EZ I (KH-EZ I) Design Guidelines For KWIK HUS-EZ Ii Values for Normal Weight and Lightweight Concrete Characteristic Symbol Units Value Internal Thread Diameter of Head d in. 1/4 or 3/8 Wrench Socket Size w in. 3/8 or 1/2 Nominal Diameter d in. 1/4 Drill Bit Diameter d bit in. 1/4 Maximum Installation Torque Tnstmax 18 Maximum Impact Wrench Torque Rating3 Tj,pactmax ft-lbf 114 137 Minimum Nominal Embedment Depth hnom in. 1 5/8 21/2 Minimum Hole Depth hhoe in. 2 27/8 Critical Edge Distance Cac5 in. 2.00 2.78 Minimum Spacing at Critical Edge Distance Smincac5 in. 1.50 Minimum Edge Distance cmn5 in. 1.50 Minimum Spacing at Minimum Edge Distance in. 3.0 Minimum Concrete Thickness In minin. 3.25 4.125 Anchor Category 3 1 Steel Strength in Tension (ACI 318 D.5.2) Tension Resistance of Steel N lb. 6,070 Reduction Factor for Steel Strength 0. - 0.65 Concrete Breakout Strength in Tension (ACI 318 D.5.2) Effective Embedment Depth hef in. 1.18 1.92 Effectiveness Factor - Uncracked Concrete K encr - 24 Effectiveness Factor - Cracked Concrete Kcr - 17 Modification Factor for cracked and uncracked concrete - 1 Reduction Factor for Concrete Breakout Strength - 0.45 0.65 Pullout Strength in Tension (ACI 318 O5.3) Characteristic pullout strength, uncracked concrete (2500 psi) N lb 13056 2358 Characteristic pullout strength, cracked concrete Nper lb 6676 1166 Reduction Factor for pullout strength cI - 0.45 0.65 Characteristic Pullout Strength, Seismic (2500 psi) N lb 5346 1166 Reduction Factor for pullout strength 0, - 0.45 0.65 Values for Installation in the underside of Concrete-Filled Profile Steel Deck Assemblies2 Pullout Resistance, (uncracked concrete) - Lower Flute Npdkuflcr lb 12108 1875 Pullout Resistance, (uncracked concrete) - Upper Flute NpdeCk flCr lb 14908 1960 Pullout Resistance, (cracked concrete and seismic loads) - Lower Flute NPdCCkC( lb 6206 930 Pullout Resistance, (cracked concrete and seismic loads) - Upper Flute NpdkCr lb 7608 9759 1 The data presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2 For installations through the soffit of steel deck into concrete, anchors installed in the lower flute may be installed with a maximum one inch offset in either direction from the center of the flute. See Figure 2. 3 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. 4 applies to installations using a calibrated torque wrench. 5 Additional combinations for minimum edge distance, c,,, and minimum spacing distance, a,,,0, or s,,,,,,,,, may be derived by linear interpolation between the given boundary values. 6 The characteristic pullout resistance for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (fc/2,500)03 7 The characteristic pullout for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (fc/2,500)05 8 The characteristic pullout resistance for concrete compressive strengths greater than 3,000 psi may be increased by multiplying the value in the table by (f'c/3,000)°3 9 The characteristic pullout for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (f'c/2,500)05 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 3 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 2 - Calculated ACI 318-08 Appendix D Strength Design Capacity for Single anchor in Tension 3,4,5,6,7 Normal Weight Concrete LWCOMD 2500 psi' 4000 psi 3000 psi2 Anchor Internally Nominal Uncracked Cracked Size Threaded Embedment (in.) Head (in.) Depth (in.) Uncracked Cracked Seismic Uncracked Cracked Seismic Concrete Concrete Lower Upper Lower Upper Concrete Concrete Concrete Concrete Flute Flute Flute Flute 1/4 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4x1-5/8 3/8 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4 2-1/2 1533 758 758 1940 958 958 1218 1275 605 634 1/4x2-1/2 3/8 2-1/2 1533 758 758 1940 958 958 1218 1275 605 634 1 Values for other strengths can be calculated per (f'c/2500)0'3 for 1-5/8 embedment and (f'c/2500)05 for 2-1/2 embedment 2 Values for other strength can be calculated per (f'c/3000)03 for 1-5/8' embedment and (f'c/3000)05 for 2-1/2 embedment 3 Based on single anchor with edge and spacing values greater than those given as critical values in Table 1. 4 Based on lower value of concrete breakout or pullout strength 5 These loads are factored resistance loads in accordance with Chapter 9 of ACI 318-08 (N). 6 Interpolation of values for other embedments is not permitted 7 Minimum concrete thickness and edge distance must comply with Table 1. Table 3- KWIK HUS-EZ I (KH-EZ I) Allowable Stress Design Values for Illustrative Purposes 11,2,3,4,1,6,7,8,9,10,11 Internal Thread Diameter Nominal Anchor Diameter Embedment Depth, hnom Depth, hei Effective Embedment Allowable Tension Load of Head (in.) (in.) (in.) (mm) (in.) (mm) lb (kN) 1-5/8(41) 1.18(30) 470(2.1) 1/40r3/8 1/4 2-1/2(64) 1.92 (49) 1340 (6.0) For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 Section 9.2 (no seismic loading). 4 40% dead load and 60% live load, controlling load combination 1.2D + 1.6L 5 Calculation of weighted average for conversion factor a = 1.2(0.4) + 1.6(0.6) = 1.44. 6 = 4,000 psi (27.6 MPa) (normal weight concrete). 7 cai = ce c c, see Table 1. 8 h ~ ~In see Table 1. 9 Values are for Condition B where supplementary reinforcement in accordance with ACI 318 D.4.4 is not provided. 10 Allowable Tension Load = factored Load (Lesser of N or Concrete Breakout from Table 1) - 1.44 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Figure 2- Installation of KWIK HUS-EZ I (KH-EZ I) in Soffit of Concrete Over Steel Deck Floor and Roof Assemblies Mm 3/4 Structural Sand - Lightweight concrete or normal [ weight concrete over steel deck (minimum 3,000 psi) OQ Upper Flute ca 2 (Valley) /1 (Typ.) gauge steel Do deck Mm. 4-1/2' LAh0r / I Flute Edge Lower (Typ.) I Flute Mm. 1-1/4" .—D.4 kc:i__ Mm. 12" (Typ.) (Ride) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 4 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4468 1 www.hitti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 Table 4 - KWIK HUS EZ I (KH-EZ I) Allowable Stress Design Tension Values for Installations in Soffit of Concrete Over Steel Deck Floor and Roof Assemblies Internal Thread Diameter of Head (in.) Nominal Anchor Diameter (in.) Embedment Depth (in.) (mm) Effective Embedment Depth (in.) (mm) Allowable Tension Load lb (kN) Upper Flute -__________________________ Lower Flute 1/40r3/8 1/4 1-5/8(41) 1.18(30) 466(2.1) 378(1.7) 2-1/2(64) 1.92 (49) 885 (3.9) 846 (3.7) For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACl 318 Section 9.2 (no seismic loading). 4 40% dead load and 60% live load, controlling load combination 1.2D + 1.6L. 5 Calculation of weighted average for conversion factor a = 1.2(0.4) + 1.6(0.6) = 1.44. 6 V0 3,000 psi (27.6 MPa) (light weight concrete). 7 c l = c ac00, see Table 1. 8 h a h,0,, see Table 1. 9 Values are for Condition B where supplementary reinforcement in accordance with ACl 318 D.4.4 is not provided. 10 Allowable Tension Load = factored Load (Lesser of N or Concrete Breakout from Table 1) -. 1.44 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Table 5 - Kwik HUS-EZ I (KH-EZ) Tested Load Values for FM Approval for Automatic Sprinkler Systems Hanger Rod Size (in.) Screw Length FM Test Load FM Maximum Pipe Diameter (in.) Tension lb (kN)) (in.) 1 5/8 3/8 1475 (6.6) 4 21/2 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. Table 6 - Kwik HUS-EZ I (KH-EZ I) Allowable Stress Design Values for Installations into Hollow Core Concrete Panels1'2 Hanger Rod Size (in.) Mm. Effective Embedment h (in.) Allowable Load Ultimate Load Tension lb (kN) Shear lb (kN)4.5 Tension lb (kN) Shear lb (kN)4.5 1/4 13/8 455 (2.0) 485 (2.2) 1810(8.1) 1,930 (8.6) 3/8 755 (3.4) 3,025 (13.5) 1 The Admissible Anchor Location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm Admissible Anchor Location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensioni configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a 4:1 factor of safety. 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of ASTM A193, Grade B7 (mm. tensile strength 125 ksi) screws used to fasten the shear fixturing. Shear values should consider the screw or threaded rod strength. Figure 3- Installation of KWIK HUS-EZ I (KH-EZ I) in Hollow Core Concrete 3.3.5.4 Installation Instructions Use the installation instructions that are including with the Kwik HUS-EZ I packaging box. To obtain a digital copy of the Installation Instructions, visit www.us.hilti.com, www.hilti.ca or contact Hilti Technical Support. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 5 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor The data below is developed from testing performed in accordance with ACI 355.2. It is intended for applications designed according to CSA A23.3-04 Update No. 3 (August 2009) Design Of Concrete Structures Annex D and is generally suitable for the conditions described in the introduction of Annex D. Table 7- KWIK HUS-EZ I (KH-EZ I) Mai Design Guidelines For KWIK HUS-EZ 11 Values for Normal Weight and Lightweight Concrete Characteristic Symbol Units Value Internal Thread Diameter of Head in. 1/4 or 3/8 Wrench Socket Size in. 3/8 or 1/2 Nominal Diameter da in. 1/4 Drill Bit Diameter d9t in. 1/4 Maximum Installation Torque T ft-lbf(Nm) 18 (24) Maximum Impact Wrench Torque Rating3 T. ft-Ibf (Nm) 114 (154) 137(186) Minimum Nominal Embedment Depth hnom mm 41 1 64 Concrete material resistance factor cx,c - 0.65 Steel material resistance factor cl - 0.85 Ultimate Strength of anchor steel f MPa 924 Effective cross-sectional area of anchor Ase mm2 29.0 Minimum Hole Depth h61 mm 51 1 73 Minimum Spacing at Critical Edge Distance s 0 5 mm 38 Minimum Edge Distance 0mm 5 mm 38 Minimum Spacing at Minimum Edge Distance SM1n5 mm 76 Minimum Concrete Thickness h. mm 83 105 Anchor Category 3 1 Steel Strength in Tension (CSA A23.3_D.6.1) Factored Steel Resistance in Tension Nsr kN 15.9 Reduction Factor for Steel Strength R - 0.70 Concrete Breakout Strength in Tension (CSA A23.3 D.6.2) Effective Embedment Depth h mm 30 1 49 Critical Edge Distanc& C aG 5 mm 51 1 71 Effectiveness Factor - Uncracked Concrete Kuem - 10 Effectiveness Factor - Cracked Concrete Kcr - Modification Factor for cracked and uncracked concrete 1p,. - 1.4 Reduction Factor for Concrete Breakout Strength R - 0.70 1.00 Pullout Strength in Tension - Non Seismic Applications (CSA A23.3 D.6.3) Factored Pullout Resistance, uncracked concrete (17.23 MPa) Nproncr kN 2.66 6.8 Factored Pullout Resistance, cracked concrete (17.23 MPa) Np,cr kN 1.36 3•47 Concrete Resistance Factor for pullout strength c,puI - 0.65 Factored Pullout Strength, Seismic (17.23 MPa) Npreg kN 1.16 1 347 Concrete Resistance Factor for pullout strength cseis - 0.65 Values for Installation in the underside of Concrete-Filled Profile Steel Deck Assemblies2 Factored Pullout Resistance, (uncracked concrete 20.68 MPa) - Lower Flute NprdKncr kN 2.48 549 Factored Pullout Resistance, (uncracked concrete 20.68 MPa) - Upper Flute Npr46unc, kN 3.08 579 Factored Pullout Resistance, (cracked concrete and seismic loads 20.68 MPa) - Lower Flute NprkCr kN 1.38 2.7 Factored Pullout Resistance, (cracked concrete and seismic loads 20.68 MPa) - Upper Flute Nprdeokc, kN 1.58 2.8 1 The data presented in this table is to be used in conjunction with the design criteria of CSA A23.3-04. 2 For installations through the soffit of steel deck into concrete, anchors installed in the lower flute may be installed with a maximum one inch offset in either direction from the center of the flute. 3 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. 4 applies to installations using a calibrated torque wrench. 5 Additional combinations for minimum edge distance, c,,,, and minimum spacing distance, smno,e may be derived by linear interpolation between the given boundary values. 6 The characteristic pullout resistance for concrete compressive strengths greater than 17.23 MPa may be increased by multiplying the value in the table by (f'c/l 7.23)° 7 The characteristic pullout for concrete compressive strengths greater than 1 7.23MPa may be increased by multiplying the value in the table by (f'c/l 7.23)° 8 The characteristic pullout resistance for concrete compressive strengths greater than 20.68 MPa may be increased by multiplying the value in the table by (f'c/20.68)03 9 The characteristic pullout for concrete compressive strengths greater than 20.68 MPa may be increased by multiplying the value in the table by (f'c/20.68)0'5 6 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 3.3.5.6 Ordering Information Order Information Internal Thread Internal Thread Hole Minimum Qty Description Diameter Length Diameter Embedment (pcs) / Box KH-EZ 1/4"xl-5/8"I 1/4" 1/4' 3/8" 1/4" 1-5/8" 100 KH-EZ 1/4"x2-1/2" 11/4" 1/4" 3/8" 1/4' 2-1/2" 100 KH-EZ 1/4"xl-5/8" 13/8" 3/8" 7/16" 1/4' 1-5/8' 100 KH-EZ 1/4"x2-1/2" I 3/8" 3/8" 7/16" 1/4' 2-1/2" 100 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 HiIti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 7 Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation, corrosion, and spacing and edge distance guidelines, please refer to the Technical Guide, or contact Hilti. Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com SPOTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK- 1 weatherproof backbox or BBX- 1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX- 1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10 (250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .1 7A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. I AWARNING I In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK- 1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, Phone: 866-572-3005/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y-I PAGE 1 OF 2 01/13 POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Fig. 1 Wiring (rear view) Fig. 3 A.C. BELLS BLACK (OUT) WHITE (IN) WHITE (OUT) FROM CONTROL PANEL OR PRECEDING BELL BLACK (IN) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELYAFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. 211/16" (68) DWG# 776-1 OWG# 776-3 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance 53/4" 185 I II (146) I ii f:NllL f ".1 3 3/8" 15/8" (86) (4!) 4 1/4" (108) DWC# 776-2 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). àWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-! PAGE 2 OF 2 01/13 fip-o-h VSG POTTER LOW FLOW RATE VANE TYPE WATERFLOW The Symbol of Protection SWITCH WITH ELECTRONIC RETARD U.S. Pat. No. 3921989, Canadian Pat. No. 1009680 Other Patents Pending, Potter Electric, Rd., 1990 General Information The Model VSG is a flexible vane type of waterfiow switch for use in wet pipe water mist systems where a low flow for alarm is required. It is designed for installation in sections of 2 to 4 inch (50mm to 100mm) stainless steel or brass pipe with wall thickness in accordance with the above specifications (see "Nominal OD and Wall Thickness"). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains an output relay and an adjustable electronic retard. The relay is actuated when a flow of 3 gallons per minute (11,4 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. Afield installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC, and CSFM Listed Service Pressure: Up to 450 PSI (31 BAR) Flow Required for Alarm: 3.0 GPM (11,4 LPM) Maximum Surge: 18 FPS (5,5 m/s) Power Requirements: STANDBY: lOma at 120V AC or 1.5ma at 24V AC/DC ALARM: 40ma at 120V AC or 35ma at 24V AC/DC Contact Ratings: DPDT (Form C) 2 Amps at 0-30VDC or 0-125VAC resistive Conduit Entrances: 2 knockouts provided for 1/2' conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA 4 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/l 20°F, 4,5°C/49°C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Nominal OD and Wall Thickness: (60,3mm OD), 3,9mm to 4,5mm wall 2 1/2" (73,0mm OD), 4,8mm to 5,2mm wall 2 1/2" (76,1mm OD), 4,3mm to 4,7mm wall (88,9mm OD), 5,0mm to 5,6mm wall (114,3mm OD), 5,4mm to 6,4mm wall Service use: Water mist systems where low flow for alarm is required. Optional: Cover Tamper Switch Kit, Stock No. 0090018 Installation See Fig. 1 These devices may be mounted on a horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" +1/8" -1/16" (32mm ± 2mm). The 3" (80mm) and 4" (100mm) devices require a hole with a diameter of 2" ± 1/8" (50mm ± 2mm). Clean the inside of the pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 20 ft-lbs. (27 n-m) of torque. See Fig. 1. The vane must not rub the inside of the pipe or bind in any way. Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833. www.pottersignal.com PRINTED IN USA MFG. #5400999 - REV M PAGE 1 OF 2 5/08 VSG POTTER. LOW FLOW RATE VANE TYPE WATERFLOW The Symbol of Protection SWITCH WITH ELECTRONIC RETARD Retard Adjustment The retard time is selected by turning the appropriate switches to the off position. Example: For 45 seconds turn switches 1, 2 and 3 to the off position. Approximate time is as follows: Switch Off Time in Sec. 1thru80n 0 1 15 l&2 30 l,2,&3 45 l,2,3,&4 60 l,2,3,4,&5 75 l,2,3,4,5,&6 90 7 not used 8 not used Fig. 1 DO NOT LEAVE COVER OPT FOR O(TED P0000 OF 11LIE RETARD TWE SELECTOR SWITCH 10 INSTALL DRILL HOLE AS INDICATED I PIPE SEE I HOLE SEE I 2 to 2-1/2 I 1-1/4 + I (50 to 60nrn,) (33mm ± 2mm) I (60 to 100mm) I ± 1/8- DIR0N (50mm ± 2mm) OF WATERFLDW 1IOKItOI NUTS ALTERNATELY — 10 AN EVENTUAL 20 PT.-L6 (21 n-m) OF TORQUE I400NT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WAI00FI.OW ROLL PADDLE OH OPT N 0*0. #762-30 Fig. 2 Typical Electrical Connections -ø 16 ééø 4. 12CR 24V COO. N.O.cal.N,c 060 r. AUX. Coo ) CONTACTS I HIGH VOLTAGE RELAY ACTION 24V BELL 1 N.C. cou NC. ARM 4/6 WIRE CONTROL PANEL CIRCUIT 06 DETECTOR CIRCUIT END OF LINE RESISTOR OR I2OV24V C. N.o.cou. N.C. FROM PANEL .4 RETURN TO CONTROL PANEL 24V DC POWER 0 24V DC RELAY 240 t. NO. l.O.C.l SHOWN ENERGIZED AUX. CO L CONTACTS I I NOTE: BASE MUST BE CONNECTED TO A GOOD EARTH GROUND. LOW VOLTAGE AC LOW VOLTAGE DC DWG. p985-I Fig. 3 Switch Terminal Connections Clamping Plate Terminal I A CAUTION I -...- DWGO 923-3 When supervised circuits are used the following must be observed: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Application Warning! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Testing: The operation of the waterfiow switch and the associated alarms is to be tested upon completion of the installation and periodically thereafter in accordance with the applicable NFPA standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). A minimum flow of 3 GPM (11,4 LPM) is required to activate this device. PRINTED IN USA MEG. #5400999 - REV M PAGE 2 OF 2 5/08 110 Me In11 10110iII1 IN Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve The AGF Model 1011A TESTANDRAIN® provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief (NFPA 13 and NFPA 13R). The Model 1011A features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 1011A is available in a full range of sizes (3/4' to 2') with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (UL/FM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). Complies with NFPA 13 and NFPA 13R Requirements Compact, Single-Handle Ball Valve Tamper-Resistant Test Orifice and Sight Glasses 300 PSI rated. Specifiable orifice sizes: %" (2.8K), 7A6" (4.2K), ½" (5.6K), 17/32" (8.0K), /8" (11.2K, ELO), 3/4" (14.0K, ESFR), and K25 Relieves Excess System Pressure caused by Surges or Temperature Changes Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. iiflãflll4 SS-M101 1A_V001 06/13 TESTaDRAIN" is registered trademark of AGF Manufacturing Inc. NNE Dimensions 'fflo1eI1EDJ111 LISTED ell UIS2U&M Model 1011 A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve APPROVED Factory Rated at 175 PSI with other setting available Model 1011 - Front View SIZE A B C D E F G H 3/4" 7/is" 11/2" 2A6" 3/8" 3/8" 113/16" 4A& 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 7A6" 11/2" 23/16" 3%" 3/8" 11A6" 49/i6" 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4 715A6" 111A6" 29/16" 41/4" 3/8" 115A6' 59/16" 71/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½" 815/16" 113A6" 31/4" 51/e" 37/s" 25/8" 81/4" 10%" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815A6" 113A6" 31/4" 51/16" 3/8" 25/8" 8¼" 107/8" (227 mm) (45 mm) (81.5 mm (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) The Model 1011 provides the following... From the 2013 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.24.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.1 7.4.2.2 The test connection valve shall be accessible. Chapter 8.1 7.4.2.4 shall be permitted to be installed in any location.., downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1 'in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1 , at least one of which shall be brass. Chapter 7.1 .2 - a wet pipe system shall be provided with a listed relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A listed relief valve of not less than ½' in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding rated pressure of the system. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve Model 1011 - Plan View Orifice Sizes %%'/16%1/2 ', 17/32 /8' ELO*, 3/4' ESFR*, and K25** Materials Handle ................Steel Stem ...................Rod Brass Ball ...................... C.P. Brass Body...................Bronze Valve Seat ...... .....Impregnated Teflona Indicator Plate .... Steel Relief Valve.........Bronze Bypass Fittings... Brass Bypass Tubing.... Nylobraid Approvals UL and ULC Listed: (EX4019 & EX4533) FM Approved 4_-W@E~ NYC-BSA No. 720-87-SM MADE IN U.S.A. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 A Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com 'Available On 11/4 to 2' size units only • "Available On 11/2 and 2 size units only Job Name: Architect: Engineer: Contractor: FireLock® Butterfly Valve Atauii Style 705 with Weatherproof Actuator 10.81 1.0 PRODUCT DESCRIPTION Available Sizes: 2 - 12750 - 300 mm cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. Designed for fire protection services only. Features a weatherproof actuator housing Approved for indoor and outdoor use. Actuation options: Hand wheel (2 - 12/50 - 300 mm) Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS c® E LISTED G410001 104j/04 NOTES Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date vifiiiIirtrnm 10.81 5662 Rev G Updated 08/2016 0 2016 Victaulic company. All rights reserved. 1 .tauIic• victaulic.com 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 50 up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 21/2 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 80 up to 300psi/2068kPa up to 300ps1/2068kPa up to 300ps1/2068kPa up to 300psi/2068kPa 100 up to 300psi/2068kPa up to 300ps1/2O68kPa up to 300psi/2068kPa up to 300psi/2068kPa 1 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7mm up to 300psi/2068kPa I up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 1 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS - MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 - 6"I50 - 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 - 12"/200 - 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade "E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with IFE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: O 2-8/50 - 200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing E] 10— 12/250-300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 2 ___________ victaulic.com 4.0 DIMENSIONS Style 705 Size Dimensions Actual Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 - - 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 - 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 761 mm 3.000 3.77 2.28 7.54 - 400 4.22 4.50 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 - - 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 108 mm 4.250 4.63 2.88 - 8.81 - - 5.50 4.22 4.50 2.20 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 - 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 133 mm 5.250 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 1397mm 5.500 5.88 3.35 10.88 - 6.56 6.19 6.30 2.58 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 - - - 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 159mm 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 1651 mm 6.500 5.88 3.84 11.38 0.41 7.52 6.19 6.30 2.58 165.1 149.4 975 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 - 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 - 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 6.50 7.36 16.64 2.30 2.80 1 71.1 14.25 8.10 9.00 323.9 323.9 165.1 186.9 422.7 58.4 362.0 205.7 228.6 NOTE Optional W/15mm tap available. Contact Victaulic for details. 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. viCtaulic.com 3 '..j4'tauiic victaulic.com 5.0 PERFORMANCE Style 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter MM mm Feet/rn inches inches of pipe 2 2.375 6 50 60.3 1.8 21/2 2.875 6 65 73.0 1.8 76.1 mm 3.000 76.1 18 3 3.500 7 80 88.9 2.1 4 - 4.500 8 100 114.3 2.4 108 mm 108 mm 284 5 - 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6.500 14 42 8 - 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 F7 7~7 12.750 19 323.9 5.8 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 4 '1.,4tauiic victaulic.com 5.1 PERFORMANCE Style 705 Cv values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, values Formulas for K values = Q2 Where: tip Q = Flow (GPM) AP = Pressure Drop (psi) Q = C x j2 C= Flow Coefficient Q = Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches Cv mm mm 2 2.375 17 0 50 60.3 2½ 2.875 2 60 65 73.0 76.1 mm 3.000 260 76.1 3 3.500 440 80 88.9 4 4.500 820 100 114.3 108mm 108mm 820 5 5.563 1200 125 141.3 133 mm 133mm 1200 139.7mm 35 1200 6 6.625 1800 150 168.3 ---------- 159 mm 159 mm 1800 165.1 mm 6.500 1800 165.1 8 8.625 3400 200 219.1 10 10.750 5800 250 273.0 12 12.750 ....- ., - 9000 300 323.9 Where: Q = Flow (m3/hr) AP = Pressure Drop (Bar) K = Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches mm mm 2 2.375 147 50 60.3 21/2 2.875 225 65 73.0 76.1 mm 3.000 225 76.1 3 3.500 380 80 88.9 4 4.500 710 100 114.3 108mm 108mm 710 5 5.563 1040 125 141.3 133 mm 133 mm 1040 139.7mm 5.500 1040 139.7 6 6.625 1560 150 168.3 159 mm 159 mm 1560 165.1 mm 6.500 1560 165.1 8 8.625 2940 200 219.1 10 10.750 5020 250 273.0 12 12.750 7790 300 323.9 10.81 5662 Rev G Updated 08/2016 © 2016 victaulic Company. All rights reserved. victaulic.cnm JtauIic 6.0 NOTIFICATIONS A WARNING %law Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring The supervisory switch contains two single pole, double throw, pre-wired switches. Switches are rated: 10 amps © 125 or 250 VAC/60 Hz 0.50 amps © 125 VDC 0.25 amps © 250 VDC Switches supervise the valve in the 'OPEN" position. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 insulated ground lead (green) is provided. Switch #1 = 51 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe ULLISTSD JUNCTION BOX CONDUIT NPT CONDUIT CONNECTORS V.TRE NUTS FIRE ALARM TO END-OF-LINE RESISTOR, CONTROL PANEL OR NEXT INDICATOR SUPERVISORY CIRCUIT C. (J W.,21COM. SWITCH CONTACT RATING: IOAAT125 AND 25OVAC, 05A AT 125 VDC, 0.25 AT 2S0 VDC VOLTAGE SOURCE Switch 1:2 leads per terminal Switch 2:1 lead per terminal NOTES The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe - S2) and the normally closed terminal (blue - Si and blue-with-orange stripe - S2). In this example: the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). ROLL OR HORN 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 6 iictaulliiiic~ victaulic.com 7.1 REFERENCE MATERIALS 1001: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty 1-100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing is this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks V/cfau/ic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/sr other countries. 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved, victaulic.com \/tauIic MODEL MVC-15 METRAVENT AUTOMATIC AIR VENT APPROVED 175 P.S.I. 5 PART PART NAME MATERIAL PART PART NAME MATERIAL 1 BODY CAST IRON A126 7 COVER BOLT CARBON STEEL 2 COVER CAST IRON A126 8 FLOAT ARM STAINLESS STEEL 3 LEVER FRAME STAINLESS STEEL 9 ORIFICE BUTTON FLUOROELASTOMER 4 SEAT STAINLESS STEEL 10 PIVOT PIN/RETAINER STAINLESS STEEL 5 FLOAT STAINLESS STEEL 11 PIPE PLUG (0.5) STAINLESS STEEL 6 GASKET NON ASBESTOS 12 LOCATOR STAINLESS STEEL QTY SIZE PART NUMBER MAX TEMP INLET SIZE OUTLET SIZE ORIFICE SIZE WI (LBS) 1/2 (15mm) MVC15005O 250°F 1/2 NPT 1/2" NPT 1/16" 5-1/2 3/4" (20mm) MVC150075 250°F 3/4" NPT 1/2" NPT 1/16" 5-1/2 1" (25mm) MVC150100 250°F 1" NPT 1/2" NPT 1/16" 5-1/2 NSF 372 - LEAD FREE The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Material complies with state codes and standards, where applicable, requiring reduced lead content. CUSTOMER: PROJECT: ENGINEER: REV. 1 PART NUMBER UPDATED DATE 2/28/2017 21211, HUBBARD ST, CHICAGO, IL 60612 e 1tIx TEL: 312-738-3800 Metra ® FAX: 312-738-0415 for pipes in motion WWW.METRAFLEX.COM MODEL MVC-15 METRAVENT AUTOMATIC AIR VENT SCALE: IDRAWINIG NUMBER: MODEL MVC-30 METRAVENT AUTOMATIC AIR VENT MAX WORKING PRESSURE 300 PSI @150°F 260 PSI © 250°F PART PART NAME MATERIAL PART PART NAME MATERIAL 1 BODY CAST IRON A126 7 COVER BOLT CARBON STEEL 2 COVER CAST IRON Al 26 8 FLOAT ARM STAINLESS STEEL 3 LEVER FRAME STAINLESS STEEL 9 ORIFICE BUTTON FLUOROELASTOMER 4 SEAT STAINLESS STEEL 10 PIVOT PIN/RETAINER STAINLESS STEEL 5 FLOAT STAINLESS STEEL 11 PIPE PLUG (0.5) STAINLESS STEEL 6 GASKET NON ASBESTOS 12 LOCATOR STAINLESS STEEL QTY SIZE PART NUMBER MAX TEMP INLET SIZE OUTLET SIZE ORIFICE SIZE WT (LBS) 1/2' (15mm) MVC300050 250°F 1/2 NPT 1/2 NPT 1/16" 8 3/4" (20mm) MVC300075 250°F 3/4 NPT 1/2 NPT 1 /1 6" 8 1" (25mm) MVC300100 250°F 1 NPT 1/2 NPT 1/16" 8 NSF 372 - LEAD FREE The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Material complies with state codes and standards, where applicable, requiring reduced lead content. CUSTOMER: PROJECT: ENGINEER: REV. 1 I PART NUMBER UPDATED DATE 2/28/2017 2323 W. HUBBARD ST. CHICAGO, IL 60612 1MetrafIe x TEL: 312-738-3800 ® FAX: 312-738-0415 pipes in motion1 WWW.METRAFLEX.COM (for MODEL MVC-30 METRAVENT AUTOMATIC AIR VENT DRAWN BY: DKISH I DATE: 9/4/2015 SCALE: I DRAWING NUMBER: UL/ULC Listed* Description The 1/4" IPS three-way female threaded valve is used to facili- tate the installation of sprinkler system pressure gauges. The valve provides for one inlet and two outlets. This design allows for replacement of the system gauge without shutting down the water supply to the sprinkler system. This design also allows Authoritys' Having Jurisdication to test system pressure with an additional gauge through the second outlet. (The second outlet is normally plugged during installation with a 1/4" IPS pipe plug.) Installation Specifications Materials: Seat- Brass Body- Brass Handwheel - Iron Sizes: 1/4" IPS Working Pressure: 400 WOG Installation of the three-way valve can be accomplished with normal field installation tools. Make sure the valve is installed according to the flow indication arrow that has been cast into the valve body. The most common installation Thread Sealing Tape or a suit- able pipe thread sealant such as PipeFit® Thread Sealant Paste with PTFE when in- stalling the valve. DO NOT OVERTIGHTEN THREADS. OVERTIGHTENING MAY CAUSE VALVE FAILURE. allows for a 1/4" IPS nipple *UL/ULC Listed 2R97 between the valve and the water supply being measured. This assures there will be ad- equate spacing for the sprin- kler system gauge from the riser. Use either PTFE Pipe Fire Protection Products, Inc. ©2003-2007 Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 --s-1 For For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com F P P I & Pipef it® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique pipefit blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Specifications ¶ Description Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIG 1 gl. 5g1. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPPI®, LubeRt" are registered trademarks of Fire Protection Products, Inc. FBC', BlazeMaster®, FlowGuard Gold' and Co,zan® are registered trademarks of Noveon IP Holdings Corp. U.S.A. DIEGO SEAL, 7635 RONSON ROAD • SAN DIEGO, CA 92111 • TEL: 858-278-3270 • FAX: 858-278-2950 E-MAIL: sales@sandiegoseal.com • VISIT US AT: www.sandiegosea1.com PTFE Thread Sealant Tapes Made in the USA ur thread sealant tape breaks clean without shredding r warping, identifying it as a product that can be trusted perform reliably when the job is completed and the ressure is on. Standard Grade Our standard grade PTFE Thread Sealant Tape is for those applications that do not require the sealing properties of a premium grade thread sealant. This is intended to be used for general purpose sealing in pipe threads. The standard density virgin PTFE sealant tape permits quick, clean, economical sealing of male pipe threads of all sizes and reduces the risk of system contamination common with liquid and paste sealants. It is effective and efficient so you can use less tape. Tears cleanly.. .seals neatly Quick sealing: This premium high density PTFE sealant tape permits quick, clean sealing of male pipe threads of all sizes and eliminates the risk of system contamination common with liquid and paste sealants. Self-lubricating: The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble, and extends the fatigue life of sealed connections. Durable: Totally maintenance free premium high density PTFE thread sealant tape is virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-240°C) to +500°F (+260°C), and pressures from hard vacuum to 10,000 PSI. PTFE Thread Sealant Tapes k of system contamination common with liquid and paste sealants. Our full density premium and gas line tapes meet ii Spec A-A 58092 for liquid & gaseous oxygen applications. The self-lubricating quality of this unsintered tape akes joints easy to assemble and disassemble. Totally maintenance free, full density PTFE thread sealant tape is tually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-0°C) to +500°F (+260°C), and pressures from a hard vacuum to 10,000 PSI. properties of PTFE thread sealant tape are as follows: Typical Properties Grade Standard Grade Premium Grade Premium Grade Premium Grade - Yellow 3tandard Density -lh Density JFull Density !ulI Density 4aximum sealing omplies with certain ower. So efficient, ullding codes requiring Description rhe economical choice Vlore sealing power ou can use less ellow, thicker, more ense tape for gas ape. ervice lines Color white or colors White or colors White or colors frellow Density IStandard 0.5 to 0.7 IStandard 1.0 to 1.2 IStandard 1.5 tandard 1.6 Thickness ).003" to 0.0035" - .003" to 0.0035" .003" to 0.0035" I Standard Widths & h" x 260" /° x 520" /" x 1296" /2" x 260" /2" x 520" /2" x 1296" Lengths Y4" x 260" Y4" x 520" 7+" x 1296" 1" x 260" 1" x 520" 1" x 1296" Quantity 144 rolls per 144 rolls per box 144 rolls per box Nhite All industrial applications. Made from virgin PTFE :link For use in plumbing and pipe fittings (water and steam lines) IN For stainless steel pipe/fittings 3reen For oxvqen applications Yellow For gas line use SAN DIEGO SEAL, INC 7635 RONSON ROAD • SAN DIEGO, CALIFORNIA 92111 TEL: 858-278-3270 9 FAX: 858-278-2950 E-MAIL: salessandiegoseal.com • VISIT US AT: www.sandiegoseal.com