Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FPC2021-0197; PermitI1iI1lIiI4I No Print Date: 01/28/2022 Job Address: 5781 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121304400 Track #: Valuation: $997,639.50 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Permit No: FPC2021-0197 Status: Closed - Finaled Applied: 10/14/2021 Issued: 11/10/2021 Finaled Close Out: 01/28/2022 Inspector: Final Inspection: Project Title: Description: THERMO FISHER GOLD RUSH PHI PART 2 - PREACTION SYSTEM WITH SPRINKLER TI (104 HEADS) Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST POWAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 System > 100 heads (includes 1 riser) $944.00 FIRE Pre-Action System with Alarm $607.00 Total Fees: $1,551.00 Total Payments To Date: $1,551.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov FR EVE IF D T F r TI M ti Western Fire Protection Inc. ThermoFisher Scientific Gold Rush Tenant Improvement 5781 Van Allen Way Carlsbad, CA 92008 Automatic Wet Fire Sprinkler System 21-3573-02 Phase 2 Hydraulic Calculations 10-8-2021 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 - - - - . - Western Fire Protection Inc. 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 No. 226 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Thermo Fisher (All areas Nos. 2 - 7) SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 5781VanAlIenWay CITY: Carlsbad PHONE: ( 858) 513-4949 x1310 (Western Fire Protection) FAX NUMBER: Largest Building (ft.2): Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Van Allen Way west of College Blvd TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 131 PSI Hydrant Number (if applicable):H61391 & H61385 Elevation of test: 248 Feet Main Size: 8 INCH Pressure Zone: 550 Feet Date/Timeof Test: Pitot Tube Reading:_Psli Corresponding flow. GPM Total Flow: 2,700 GPM Residual Pressure 108 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this exceeds the City's maximum velocity criteria. The fire flow that meets both velocity and pressure criteria is 2,700 gpm. Flow was split evenly between the two hydrants shown. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable): C69606 Title/Or: P nf Date: 05/07/2020 Cb CO 00 Fire Flow Test Location H61385 PRS lb Project Site Fire Flow Test Location H61391 College 550/430 PRS $ #226 Thermo Fisher (5781 Van Allen Way) — Fire Flow Analysis Hydraulic Calculations for Project Name: Thermo Fisher - Project Gold Rush Location: 5781 Van Allen Way, Carlsbad, CA 92008, Drawing Name: PRG_FP_WFP_PHASE 2 Calculation Date: 10/8/2021 #3 - Rack Overhead System Rack Overhead System FM Storage Class l-IV, Cartoned Expanded/Unexpanded Group A 0.300gpm/ft2 0.00ft2 (Actual 787.67ft2) 80.00ft2 Upright 15 N/A gpm at Node: N/A 0.0 gpm at Node: I Type: Allowance at Source 500.00 at Node: 21 Type: Hydrant Design Remote Area Number: Remote Area Location: Occupancy Classification Commodity Classification Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: In-rack Demand: Hose Streams: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 1835.53 @ 91.892 Type of System: Wet Volume of Dry or PreAction System: 0.96ga1 Name of Contractor: Western Fire Protection Address: 13630 Danielson Street, Poway, CA 92-64 Phone Number: 858-513-4949 Name of designer: Grant Coito Authority Having Jurisdiction: City of Carlsbad Notes: Automatic peaking results Left: 89.463 Right: 90.693 &© M.E.P.CAD, Inc. AutoSPRlNK 2018 04.4.5.0 #3 - Rack Overhi 10/8/202111:01:39AM Page 1 Hydraulic Calculations for Project Name: Thermo Fisher - Project Gold Rush Location: 5781 Van Allen Way, Carlsbad, CA 92008, Drawing Name: PRG_FP_WFP_PHASE 2 Design Remote Area Number: #5 - Rack Sprinklers Remote Area Location: Rack Sprinklers Occupancy Classification: Racks Calculation Date: 10/8/2021 Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: 0.000gpm/ft2 0.00ft2 (Actual 120.66ft2) 96.001t2 Upright 14 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: 1 Type: 500.00 at Node: 21 Type: Total Water Required (including Hose Streams where applicable): Type of System: Wet Volume of Dry or PreAction System: 0.96ga1 Allowance at Source Hydrant Name of Contractor: Western Fire Protection Address: 13630 Danielson Street, Poway, CA 92-64 Phone Number: 858-513-4949 Name of designer: Grant Coito Authority Having Jurisdiction: City of Carlsbad Notes: Automatic peaking results Left: N/A Right: 91.969 M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 #5 - Rack Sprink 10/8/202111:01:39AM Page 2 IHydraulic Summary Job Number: 21-3573-02 Report Description: FM Storage (#3 - Rack Overhead System), Racks (#5 - Rack Sprinklers Job Job Number 21-3573-02 Design Engineer Grant Coito Job Name: Thermo Fisher - Project Gold Rush State Centiraationll.iuonso Number Address I 5781 Van Allen Way AHJ City of Carlsbad Address 2 Carlsbad, CA 92008 Job Site/Building Add— 3 Drawing Name PRGJP_WFP_PHASE 2 System Remote Area(s) Most Demanding Sprinkler Date 11.2 K-Factor 44.80 at 16.000 Occupancy FM Storage Job Suffix Nasa Allowance At Source 0.00 Density 0.300gpm/ft2 Area clAppliostion 0.00ft2 (Actual 787.67ft2) Additional Hose Supplies Node Flow(ciom) Hydrant At Node 21 500.00 Number Of Sprinklers Calculated 15 Coverage Per Sprintder 80.00ft2 AutoPeak Results, Pressure For Remote Area(s) Adjacent To Most Remote Area Left: 89.463 Right: 90.693 Ouaupancg Racks Job SatSa Density 0.000gpm/ft2 Area ofApplisetior 0.001t2 (Actual 120.66ft2) Number Of Sprinklers Calculated 14 Couenege Per Sprtntder 96.00ft2 Autopeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Right: 91.969 0.96ga1 Total Hose Streams 500.00 System Flow Demand 1835.53 Total yclater Rngulred (Including Hose Allowance) 1835.53 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 25.64 between nodes 142 and 3012 Maximum Velocity Under Ground 12.61 between nodes 1 and 2 Volume capacity at Wet Pipes 11879.84ga1 Volume capacity of Dry Pipes Supplies Node Name Hose Flow (gpm) Static (psi) Residual (psi) Flow (gpm) Available (psi) @ Total Demand (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 117.900 97.200 2700.00 107.763 1835.53 91.892 15.871 Contractor ©M.E.P.CAD, Inc. JAutoSPRlNK 2018 04.4.5.0 10/8/2021 11:02:08AM Page 1 ~jjljkydraulic Summary Job Number: 21-3573-02 Report Description: FM Storage (#3 - Rack Overhead System), Racks (#5 - Rack Sorinklers) Contractor Number Contact Name Contact brA 21-3537-02 Grant Coito Designer Name of Contractor. Western Fire Protection Phone 858-513-4949 Ecterrolon Add.. I 13630 Danielson Street FAX 858-513-1322 Address 2 Poway, CA 92-64 E-mail grantwesternfireprotection.com Address 3 Web-SEe © M.E.P.CAD, Inc. Auto SPRINK 2018 v14.4.5.0 10/8/2021 11:02:08AM Page 2 1111 Summary Of Outfiowing Devices Job Number: 21-3573-02 Report Description: FM Storage (#3 - Rack Overhead System), Racks (# Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) 5 - Rack Sprinklers Hydrant 21 50000 500.00 0 85.999 Sprinkler 3001 65.16 44.80 11.2 33.846 Sprinkler 3002 64.95 44.80 11.2 33.632 Sprinkler 3003 64.92 44.80 11.2 33.596 Sprinkler 3004 55.10 44.80 11.2 24.201 Sprinkler 3005 44.96 44.80 11.2 16.112 Sprinkler 3006 54.45 44.80 11.2 23.636 Sprinkler 3007 54.34 44.80 11.2 23.544 ' Sprinkler 3008 44.80 44.80 11.2 16.000 Sprinkler 3009 54.36 44.80 11.2 23.556 Sprinkler 3010 55.40 44.80 11.2 24.472 Sprinkler 3011 47.21 44.80 11.2 17.768 Sprinkler 3012 57.60 44.80 11.2 26.446 Sprinkler 3013 70.21 44.80 11.2 39.301 Sprinkler 3014 70.16 44.80 11.2 39.244 Sprinkler 3015 70.22 44.80 11.2 39.313 Sprinkler 5001 33.85 30.00 8 17.901 Sprinkler 5002 33.91 30.00 8 17.970 Sprinkler 5003 34.18 30.00 8 18.250 Sprinkler 5004 35.61 30.00 8 19.816 Sprinkler 5005 35.69 30.00 8 19.902 Sprinkler 5006 34.04 30.00 8 18.109 Sprinkler 5007 34.11 30.00 8 18.182 Sprinkler 5008 30.88 30.00 8 14.901 Sprinkler 5009 30.94 30.00 8 14.960 Sprinkler 5010 31.18 30.00 8 15.195 Sprinkler 5011 32.51 30.00 8 16.515 Sprinkler 5012 32.58 30.00 8 16.588 Sprinkler 5013 31.06 30.00 8 1 15.076 Sprinkler 5014 31.12 30.00 1 8 15.137 r-> Most Demanding Sprinkler Data (, © M.E,P.CAD, Inc. E.IlAutoSPRINK 2018 04.4.5.0 10/8/2021 11:01:43AM Page 4 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack S Date: 10/8/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 117.900 97.200 1 2700.00 107.763 1835.53 91.892 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3-0 Supply 91.892 1835.53 21 2-0 Hydrant 85.999 500.00 3001 30-3% Sprinkler 33.846 65.16 3002 3071/2 Sprinkler 33.632 64.95 3003 3111/2 Sprinkler 33.596 64.92 3004 30-6 Sprinkler 24.201 55.10 3005 3051/2 Sprinkler 16.112 44.96 3006 3051/2 Sprinkler 23.636 54.45 3007 30-7 Sprinkler 23.544 54.34 3008 309h/2 Sprinkler 16.000 44.80 3009 30-9% Sprinkler 23.556 54.36 3010 310h/2 Sprinkler 24.472 55.40 3011 31-4 Sprinkler 17.768 47.21 3012 3131/2 Sprinkler 26.446 57.60 3013 30-10 Sprinkler 39.301 70.21 3014 30-9 Sprinkler 39.244 70.16 3015 30-9 Sprinkler 39.313 70.22 5001 9-4 Sprinkler 17.901 33.85 5002 9-4 Sprinkler 17.970 33.91 ,© M.E.p.cAD, Inc. lilAutoSPRINK 2018 04.4.5.0 10/8/2021 11:01:46AM Paqe 5 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack S Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 5003 9-4 Sprinkler 18.250 34.18 5004 9-4 Sprinkler 19.816 35.61 5005 9-4 Sprinkler 19.902 35.69 5006 9-4 Sprinkler 18.109 34.04 5007 9-4 Sprinkler 18.182 34.11 5008 19-4 Sprinkler 14.901 30.88 5009 19-4 Sprinkler 14.960 30.94 5010 19-4 Sprinkler 15.195 31.18 5011 19-4 Sprinkler 16.515 32.51 5012 19-4 Sprinkler 16.588 32.58 5013 19-4 Sprinkler 15.076 31.06 5014 19-4 Sprinkler 15.137 31.12 2 -3-0 91.822 3 4-0 88.770 4 -3-0 88.057 5 -3-0 87.044 6 -5-0 80.213 7 -3-0 76.381 8 1-0 Gauge 74.287 22 -3-0 88.273 100 28-9 59.076 101 28-9 56.448 102 29-3 52.748 ,© M.E.P.CAD, Inc. III AutoSPRlNK 2018 04.4.5.0 10/8/2021 11:01:46AM Page 6 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack S Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 103 28-9 56.001 104 29-3 52.721 105 28-9 55.582 106 29-3 52.698 107 28-9 55.188 108 29-3 52.651 109 28-9 54.817 110 29-3 52.577 111 28-9 54.465 112 29-3 52.473 113 28-9 54.132 114 29-3 52.337 115 28-9 53.816 116 29-3 52.166 117 28-9 53.515 118 29-3 51.961 119 28-9 53.228 120 29-3 51.718 121 28-9 52.956 122 29-3 51.437 123 28-9 52.697 124 29-3 51.105 125 28-9 52.456 ,© M.E.P.CAD, Inc. 111AutoSPRINK 2018 04.4.5.0 10/8/2021 11:01:46AM Page 7 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack S Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 126 29-3 50.722 127 28-9 52.227 128 29-3 50.293 129 28-9 52.013 130 29-3 49.805 131 28'-9 51.815 132 29'-3 49.250 133 28-9 51.632 134 29-3 48.479 135 28-9 51.468 136 29-3 47.593 137 28-9 51.322 138 29-3 46.583 139 28-9 51.217 140 29-3 45.427 141 28-9 51.143 142 29'-3 44.535 143 28-9 51.110 144 29-3 44.238 145 28-9 51.096 146 29-3 44.076 147 28-9 51.089 148 29-3 43.983 (.,©M.E.P.CAD, Inc. IlAutoSPRINK2018v14.4.5.0 10/8/2021 11:01:46AM Page Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack S Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 149 28-9 51.087 150 29-3 44.034 200 28-9 51.316 201 13-11% 57.649 202 13-11% 57.649 204 13-11% 57.499 205 13-111/2 57.391 206 13-11% 57.386 213 13-0 56.330 214 13-0 56.319 215 29-3 49.203 300 32-5% 50.197 301 29-3 51.244 501 29-3 43.958 502 1-10 51.807 503 28-8 18.036 504 28-8 16.872 505 19-4 19.302 506 19-4 17.834 507 9-4 23.116 508 9-4 21.378 3101 30-3% 41.942 3102 30-7% 41.683 (,© M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 10/8/2021 11:01:46AM Paqe 9 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack S Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 3103 31-1% 41.640 3105 30-5% 23.682 3108 3091/2 23.521 3111 31-3 26.083 5101 9-4 19.810 5102 9-4 19.886 5103 9-4 20.193 5106 9-4 20.039 5107 9-4 20.118 5108 194 16.512 5109 19-4 16.576 5110 19-4 16.835 5113 19-4 16.704 5114 19-4 16.771 .,© M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 10/8/2021 11:01:46AM Page 10 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _________________ Friction(Pf) 3008 3091/2 11.2 44.80 i (See Notes) 8'O 120 16.000 •••••Routel Sprinkler, P0(5-0) 5 -0 0.578550 -0.000 3108 30-9% 44.80 1.0490 13-0 7.521 3108 30-9% 32.65 2 1,-0 120 23.521 Flow (q)from Route 16 0.047583 -0.013 3009 30-9% 77.45 2.1570 1-0 0.048 3009 3091/2 11.2 54.36 2 (See Notes) 8'0 120 23.556 Sprinkler 0.127256 -0.103 3010 31-0% 131.81 2.1570 8-0 1.018 3010 31-0% 11.2 55.40 2 (See Notes) 7'0 120 24.472 Sprinkler 0.243563 -0.090 3111 31-3 187.21 2.1570 7-0 1.701 3111 31-3 47.21 2 1-0 120 26.083 Flow (q) from Route 8 0.369226 -0.013 3012 31-31/2 234.42 2.1570 1-0 0.377 3012 31-3% 11.2 57.60 2 (See Notes) 6-5 120 26.446 Sprinkler, T(12'-31/2), mecT(12'-3%) 24-7% 0.554379 0.880 142 29'-3 292.02 2.1570 31 -0% 17.209 142 29'-3 360.32 4 10,-0 120 44.535 Flow (q) from Route 3 0.089166 140 29'-3 652.34 4.2600 10-0 0.892 140 29'-3 9852 4 10-0 120 45.427 Flow (q) from Route 18 0.115666 138 29'-3 750.85 4.2600 10,-a 1.157 138 29'-3 4 10,-0 120 46.583 0.100938 136 29-3 697.56 4.2600 10,-a 1.009 136 29-3 4 10-0 120 47.593 0.088595 134 29'-3 650.07 4.2600 10,-a 0.886 134 29'-3 4 9-3 120 48.479 r:9-3 0.078264 215 29'-3 607.93 4.2600 I 0.724 ,©M.E.P.CAD, Inc. jAutoSPRINK2018v14.4.5.O verhead System, #5-Rac 10/8/2021 11:01:48AM Page 11 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit Elev(Pe) ________________ Node 2 Elev 2 (Foot) Total Flow Actual ID Total I (Foot) Friction(Pf) 215 29-3 4 0-9 120 49.203 0.063317 132 29-3 542.13 4.2600 0'- 0.047 132 29-3 4 10-0 120 49.250 0.055496 130 29-3 504.84 4.2600 10,-0 0.555 130 29-3 4 10-0 120 49.805 0.048764 128 29-3 470.75 4.2600 0.488 128 29'-3 4 10-0 120 50.293 0.042912 126 29-3 439.32 4.2600 0.429 126 29-3 4 10-0 120 50.722 0.038271 124 29-3 412.97 4.2600 10-0 0.383 124 29-3 4 4-0 120 51.105 0.034812 301 29-3 392.35 4.2600 4-0 0.139 301 29'-3 4 6-0 120 51.244 0.032246 122 29-3 376.44 4.2600 6-0 0.193 122 29-3 4 10-0 120 51.437 0.028101 120 29-3 349.46 4.2600 10-0 0.281 120 29-3 4 10,-0 120 51.718 0.024236 118 29'-3 322.60 4.2600 0.242 118 29'-3 4 10-0 120 51.961 0.020565 116 29'-3 295.19 4.2600 10,-a 0.206 116 29'-3 4 10-0 120 52.166 0.017040 114 29'-3 266.67 4.2600 0.170 1,.© M.E.P.CAD, Inc. Ifl AutoSPRlNK 2018 04.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 12 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 114 29-3 4 10-0 120 52.337 0.013650 112 29-3 236.53 4.2600 10-0 0.136 112 29-3 4 10-0 120 52.473 0.0 10410 110 29'-3 204.31 4.2600 10-0 0.104 110 29-3 4 10-0 120 52.577 0.007377 108 29-3 169.61 4.2600 10-0 0.074 108 29-3 4 10-0 120 52.651 0.004652 106 29-3 132.19 4.2600 10-0 0.047 106 29-3 4 10-0 120 52.698 0.002371 104 29-3 91.83 4.2600 10-0 0.024 104 29'-3 2 (See Notes) 138'l 120 52.721 P0(12-3%) 21(12-3%), P0(12-3%) 49-2% 0.016355 0.217 103 28'-9 43.48 2.1570 187-3% 3.063 103 28'-9 1243.70 6 10-0 120 56.001 Flow (q) from Route 2 0.044632 101 28'-9 1287.18 6.3570 10-0 0.446 101 28'-9 48.35 6 (See Notes) 29'-1 10% 120 56.448 Flow (q) from Route 30 2fE(12'-7), TOR 25-2 0.047783 100 28-9 1335.53 6.3570 55-0 2.629 100 28-9 6 (See Notes) 31-4% 120 59.076 2E(17-7), BOR 35-2% 0.047783 12.030 8 1-0 1335.53 6.3570 66-7 3.181 8 1-0 8 (See Notes) 910 140 74.287 LtE(22'-0%), PlV(6-9%) 28-10 0.009301 1.734 7 -3-0 1335.53 8.3900 38-8 0.360 7 -3-0 8 (See Notes) ________ 139'2 150 76.381 E(22'-11%),T(44'-8), 2LtE(16'- 7) 100-10 0.012356 ____________ 0.867 6 -5-0 ___ 1335.53 ______ 7.7100 ________ 240-0 _________ 2.965 f, © M.E.P.CAD, Inc. jifl AutoSPRINK 2018 04.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 13 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Devices Fittings & Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as ______________________ Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 6 -5-0 8 (See Notes) 170 140 80.213 T(59'-41/2), BFP(-6.623), 2LtE( 2201/2) 103-6 0.009301 -0.867 5 -3-0 1335.53 8.3900 115-6 7.697 5 -3-0 8 (See Notes) 20'9 150 87.044 LtE(16'-7), T(44'-8) 61-3 0.012356 4 -3-0 1335.53 7.7100 82-0 1.013 4 -3-0 8 (See Notes) 974 150 88.057 EE(11 -6) 11-6 0.006557 3 4-0 948.25 7.7100 108-9% 0.713 3 4-0 500.00 8 (See Notes) 190-11 150 88.770 Flow (q) from Route 23 LtE(16-7), GV(5'-l%) 21-8% 0.014354 2 -3-0 1448.25 7.7100 21271/2 3.052 2 -3-0 387.28 8 (See Notes) 311/2 150 91.822 Flow (q) from Route 52 Water Supply 0.022252 1 -3-0 1835.53 7.7100 311/2 0.069 0.00 91.892 Hose Allowance At Source Total(Pt) Route 1 1 1835.53 3005 30-5% 11.2 44.96 1 (See Notes) 8-0 120 16.112 Route ..... Sprinkler, P0(5-0) 0.582299 -0.000 3105 30-5% 44.96 1.0490 13-0 7.570 3105 30-5% 76.15 2 5-0 120 23.682 Flow (q) from Route 17 0.108807 -0.025 3004 30-6 121.11 2.1570 6-0 0.544 3004 30-6 11.2 55.10 2 (See Notes) 95-7% 120 24.201 Sprinkler, T(12-3%), P0(12-3%) 24-7% 0.217736 0.757 141 28'-g 176.20 2.1570 120-3 26.185 141 28'-9 311.96 6 10-0 120 51. 143 Flow (q) from Route 22 0.007424 139 28'-9 488.16 6.3570 10-0 0.074 139 28'-9 96.51 6 9-6% 120 51.217 Flow (q) from Route 20 0.010366 200 28-9 584.68 6.3570 9-6% 0.099 ,©M.E.P.CAD, Inc. IIIAutoSPRlNK2O18 04.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 14 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit - (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID _________ Total (Foot) _______________ Friction(PI) 200 28'9 65.81 6 0-5% 120 51. 316 Flow (q) from Route 24 0.012627 137 28'-9 650.48 6.3570 0-5% 0.006 137 289 53.29 6 10-0 120 51. 322 Flow (q) from Route 41 0.014607 135 28-9 703.78 6.3570 10-0 0.146 135 28'9 47.49 6 10-0 120 51. 468 Flow (q) from Route 40 0.016483 133 28-9 751.26 6.3570 10-0 0.165 133 28-9 42.14 6 10-0 120 632 Flow (q) from Route 37 0.018234 131 28-9 793.40 6.3570 10-0 0.182 131 28-9 37.29 6 10-0 120 51.815 Flow (q) from Route 31 0.019851 129 28-9 830.69 6.3570 10-0 0.199 129 28-9 34.09 6 10-0 120 013 Flow (q) from Route 44 0.021384 127 28-9 864.78 6.3570 10-0 0.214 127 28-9 31.43 6 10-0 120 52.227 Flow (q) from Route 35 0.022844 10-0 125 28-9 896.21 6.3570 0.228 125 28'9 26.35 6 10-0 120 52. 456 Flow (q) from Route 28 0.024102 123 28-9 922.56 6 10-0 52.697 .3570 0.241 123 28'9 36.52 6 10-0 120 Flow (q) from Route 36 0.025897 10-0 121 28-9 959.09 6.3570 0.259 121 289 26.98 6 10-0 120 52. 956 Flow (q) from Route 27 0.027261 119 28-9 986.07 6.3570 10-0 0.273 119 28-9 26.86 6 10-0 120 53.228 Flow (q) from Route 33 0.028651 117 28-9 1012.93 6.3570 10-0 0.287 , © M.E.P.CAD, Inc. III AutoSPRINK 2018 04.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 15 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Po and shown as _ flflJ_____________________ 2thIQ tI2Ill9 Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 117 28-9 27.41 6 10,-a 120 53.515 Flow (q) from Route 32 0.030101 115 28-9 1040.34 6.3570 10,-0 0.301 115 28-9 28.52 6 10-0 120 816 Flow (q) from Route 43 0.031646 113 28-9 1068.86 6.3570 10,-0 0.316 113 28'9 30.14 6 10-0 120 54.132 Flow (q) from Route 34 0.033317 111 28-9 1099.00 6.3570 10,-0 0.333 111 28'-9 32.22 6 10-0 120 465 Flow (q) from Route 38 0.035146 109 28-9 1131.22 6.3570 10,-a 0.351 109 28'-9 34.70 6 101-0 120 54. 817 Flow (q) from Route 42 0.037167 107 28-9 1165.92 6.3570 10,-0 0.372 107 28'-9 37.42 6 101-0 120 188 Flow (q) from Route 29 0.039404 105 28'-9 1203.34 6.3570 10-0 0.394 105 28'-9 40.35 6 10-0 120 55.582 Flow (q) from Route 46 0.041883 103 28'-9 1243.70 6.3570 10,-a 0.419 56.001 Total(Pt) Route 2 5008 19-4 8 30.88 1 (See Notes) 0-6% 120 14.901 Route ..... Sprinkler, P0(5-0) 5-0 0.290678 5108 19-4 30.88 1.0490 5-6% 1.611 5108 19-4 2 751/2 120 16.512 0.008684 5109 194 30.88 2.1570 7-5% 0.065 5109 19-4 30.94 2 8'-3 120 16. 576 Flow (q) from Route 0.031364 5110 19-4 61.82 2.1570 8-3 0.259 5110 19-4 31.18 2 (See Notes) 20'-4 120 8354 16. Flow (q) from Route 7 fE(4'-3%), P0(12-3%) 16-7% 0.066767 -0.000 505 19-4 93.01 2.1570 36-11% 2.467 © M.E.P.CAD, Inc. Jil AutoSPRINK 2018 04.4.5.0 verhead System; #5 - Rac 10/8/2021 11:01:48AM Page 16 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 505 19-4 1 27.28 + 241.3 3 9-4 120 19.302 Flow (q) from Route 5 and 10 0.173108 -4.045 504 28-8 461.68 3.2600 9-4 1.615 504 28'-8 3 (See Notes) 01 0 120 16.872 fE(6'-8%) 6-8% 0.173108 503 28'-8 461.68 3.2600 6-8% 1.163 503 28-8 3 (See Notes) 62-0% 120 18.036 fT(17'-S%), 2fE(6'-8%), 2f(-0.00 0), CV(21'-6), BV(13'-5%) 65-10 0.173108 11.632 502 1-10 461.68 3.2600 127-11 22.140 502 1-10 F2600 (See Notes) 37'll 120 51.807 3fE(8'-1111/2), fT(21'-1) 47-10% 0.047039 -11.886 501 29-3 461.68 85-91/2 4.036 501 29'-3 4 4-91/2 120 43.958 0.024702 146 29-3 325.94 4.2600 4-9% 0.118 146 29-3 4 101-0 120 44.076 0.016199 144 29'-3 259.47 4.2600 10,-a 0.162 144 29'-3 100.85 4 101-0 120 44.238 Flow (q) from Route 21 0.029737 142 29-3 360.32 4.2600 10-0 0.297 44.535 Total(Pt) Route 3 5009 19-4 8 30.94 1 (See Notes) J 06h/2 120 14.960 Route 4..... Sprinkler, P0(5-a) [6-0 0.291737 5109 19-4 30.94 1.0490 I 5-6% 1.617 16.576 Total(Pt) Route 4 5013 19-4 8 31.06 1 (See Notes) 0-6% 120 15.076 Route 5 Sprinkler, P0(5-0) 5-0 0.293836 5113 19-4 31.06 1.0490 5-61/2 1.628 5113 19-4 2 7-7% 120 16.704 0.008779 5114 19-4 31.06 2.1570 7-7% 0.067 © M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 17 Job Name: Thermo Fisher - Project Gold Rush - Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Elev 1 Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Filling (Foot) Pf Friction . Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per unit when applicable, are added Total ________________ Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (P0 and shown as (Foot) 5114 19-4 31.12 2 (See 29'2Y2 120 16.771 Flow (q) from Route 6 431/ Notes) 506 19-4 62.19 2.1570 0.031706 fE(4'-3%) 33-6% 1.063 506 19-4 65.09 2 (See 01 0 120 17.834 Flow (q) from Route 9 12-3% 0.000 Notes) 505 19-4 127.28 2.1570 0.119291 P0(12-3%) 1231/2 1.468 19.302 Total(Pt) Route 5 5014 19-4 8 31.12 1 (See 0-61/2 120 15.137 Route 6••••• Sprinkler, 5-0 Notes) 5114 19-4 31.12 1.0490 0.294931 po(5'O) 5-61/2 1.634 16.771 Total(Pt) Route 6 5010 19-4 8 31.18 i (See I 0-6% 120 15.195 Route ..... Sprinkler, F 5-0 Notes) 5110 19-4 31.18 1.0490 0.295978 PO(5'O) 1 56h/2 1.640 16.835 Total(Pt) Route 7 3011 31-4 11.2 47.21 1 (See 81 0 120 17.768 Route ..... Sprinkler, 5-0 0.029 Notes) 3111 31-3 47.21 1.0490 0.637435 P0(5-0) 13-0 8.286 26.083 Total(Pt) Route 8 5011 19-4 8 32.51 2 (See 7'7% 120 16.515 "" Route 9 ..... Sprinkler Notes) 5012 19-4 32.51 2.1570 0.009551 7-7% 0.073 5012 19-4 8 32.58 2 (See 268 120 16.588 Sprinkler, 10-5% Notes) 506 19-4 6509 2.1570 0.034502 fT(10'-S%) 36-1% 1.247 17.834 Total(Pt) Route 9 5001 9-4 8 33.85 1 (See o'6% 120 17.901 Route 10 ..... Sprinkler, 6-0 Notes) 5101 9-4 33.85 1.0490 0.344429 P0(5-0) 5-61/2 1 .909 5101 9-4 2 7-5% 120 19.810 0.010290 5102 9-4 33.85 2.1570 7-5% 0.077 © M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 18 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _________________ Friction(Pf) 5102 9-4 33.91 2 8-3 120 19.886 Flow (q) from Route 11 0.037163 5103 9-4 67.76 2.1570 8-3 0.307 5103 9-4 34.18 2 (See Notes) 204 120 20.193 Flow (q) from Route 14 fE(4'-31/2), P0(12-31/2) 16 71/2 0.079106 507 9-4 101.94 2.1570 36-11% 2.923 507 9-4 139.46 3 10-0 120 23.116 Flow (q) from Route 12 0.052159 -4.335 505 19-4 241.39 3.2600 10-0 0.522 19.302 Total(Pt) Route 10 5002 9-4 8 33.91 1 (See Notes) 0-6% 120 17.970 ••"• Route ll ..... Sprinkler, P0(5-0) 6-0 0.345669 5102 9-4 33.91 1.0490 5-6% 1.916 19.886 Total(Pt) Route 11 5006 9-4 8 34.04 1 (See Notes) 06h/2 120 18.109 Route Sprinkler, P0(5.0) 5-0 0.348141 5106 9-4 34.04 1.0490 5-6% 1.929 5106 9-4 2 771 120 20.039 0.010401 5107 9-4 34.04 2.1570 7-7% 0.079 5107 9-4 34.11 2 (See Notes) 2921/2 120 20.118 Flow (q) from Route 13 fE(4'-3%) 4'- 31/ 0.037565 508 9-4 68.16 2.1570 33-6% 1.260 508 9-4 71.30 2 (See Notes) 01 0 120 21.378 Flow (q) from Route 15 P0(12-3%) 12-3% 507 9-4 139.46 "21570 0.141260 12-3% 1.738 23.116 Total(Pt) Route 12 5007 9-4 8 34.11 1 (See Notes) 0'6% 120 18.182 Route 13..... Sprinkler, P0(5-0) 5-0 0.349423 5107 9-4 34.11 1.0490 5'-6% 1.936 20.118 Total(Pt) Route 13 , © M.E.P.CAD, Inc. Ifi Autos PRINK 2018 v14.4.5.O verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 19 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Elev i Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) FittinglDevice (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (N) and shown as (Foot) najQtiIn -1- .8 5003 9-4 8 34.18 i (See 061/2 120 18.250 Route 14•"•• Sprinkler, 5-0 N Notes) 5103 9-4 34.18 1.0490 0.350632 P0(5-0) 5-6% 1.943 20.193 Total(Pt) Route 14 5004 9-4 8 35.61 2 (See 7-7% 120 19.816 Route 15 ..... Sprinkler Notes) 5005 9-4 35.61 2.1570 0.011305 7-7% 0.086 5005 9-4 8 35.69 2 (See 25'-8 120 19.902 Sprinkler, Notes) 10'-51/2 508 9-4 71.30 2.1570 0.040835 fr(10'-5%) 36 1 1/2 1.476 21.378 Total(Pt) Route 15 3007 30-7 11.2 54.34 2 (See 7-0 I 120 23.544 ..... Route 16"" Sprinkler -0.090 Notes) 3108 30-9% 32.65 2.1570 0.009625 7-0 0.067 23.521 Total(Pt) Route 16 3007 30-7 11.2 54.34 2 (See 8-0 120 23.544 Route 17 .... Sprinkler 0.056 Notes) 3006 30-5% 21.70 2.1570 0.004521 8-0 0.036 3006 30-5% 11.2 54.45 2 (See 1-0 120 23.636 Sprinkler -0.000 Notes) 3105 3051/2 76.15 2.1570 0.046119 1-0 0.046 23.682 Total(Pt) Route 17 3003 31-1% 11.2 64.92 1 (See 2-0 120 33.596 Route 18 ..... Sprinkler, 6-0 -0.000 Notes) 3103 31-11/2 64.92 1.0490 1.149076 P0(5-0) 7-0 8.044 3103 311h/2 33.60 2 (See 15.61/2 120 41 .640 Flow (q) from Route 19 24-7 % 0.805 Notes) 140 29-3 98.52 2.1570 0.074266 T(12'-31/2), mecT(12'-3%) 40-2 2.982 45.427 Total(Pt) Route 18 3002 3071/2 11.2 64.95 i (See 2-0 120 33.632 Route Sprinkler, 5-0 -0.000 Notes) 3102 307h/2 64.95 1.0490 1.150204 P0(5-0) 7-0 8.051 f, © M.E.P.CAD, Inc. Jil AutoSPRINK 2018 04.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 20 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _________________ Friction(Pf) 3102 30-7% 2 16-0 120 41.683 0.010151 -0.206 3103 3111/2 33.60 2.1570 16-0 0.162 41.640 Total(Pt) Route 19 3001 30-3% 11.2 65.16 1 (See Notes) 2-0 120 33.846 ••"• Route 2O ..... Sprinkler, P0(5-0) 5-0 1.156978 -0.003 3101 30-3% 65.16 1.0490 7-0 8.098 3101 30-3% 31.35 2 (See Notes) 9581/2 120 41.942 Flow (q) from Route 47 T(12'-3%), P0(12-3%) 24-7% 0.071496 0.674 139 28-9 96.51 2.1570 120-31/2 8.602 51.217 Total(Pt) Route 20 -71 3014 30-9 11.2 70.16 2 (See Notes) 8-0 120 39.244 Route 21 ..... Sprinkler 0.008554 0.000 3015 30-9 30.63 2.1570 8-0 0.068 3015 30-9 11.2 70.22 2 (See Notes) 30'5 120 39.313 Sprinkler, T(12'-3%), mecT(12'-31/2) 24-7% 0.077558 0.655 144 29-3 100.85 2.1570 55-0 1/2 4.270 44.238 Total(Pt) Route 21 3014 30-9 11.2 70.16 2 (See Notes) 6-0 120 39.244 Route 22 ..... Sprinkler 0.013715 -0.025 3013 30-10 39.53 2.1570 6-0 0.082 3013 30-10 11.2 70.21 2 (See Notes) 95'8% 120 39.301 Sprinkler, T(12'-31/2), P0(12-3%) 24-7% 0.090683 0.897 143 28-9 109.75 2.1570 120-4 10.911 143 28'-9 202.21 6 10-0 120 51.110 Flow (q) from Route 26 0.003243 141 28'-9 311.96 6.3570 10-0 0.032 51.143 Total(Pt) Route 22 21 2-0 500.00 6 (See Notes) I J 3-0 140 85.999 1 Route 23 ..... LtE(14'-2) 14-2 0.006192 2.168 I 22 -3-0 500.00 6.2800 17-2 I 0.106 /© M;E;P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 21 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as nJfi9 Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 22 -3-0 6 (See Notes) 23'4% 150 88.273 GV(3'-101/2), 1(38-11%) 42-10 0.007509 0.000 3 -3-0 500.00 5.8800 66-3 0.497 88.770 Total(Pt) Route 23 202 13111/2 65.81 4 0-0 120 57.649 ••.•• Route 24 ..... Flow (q) from Route 25 0.001280 -0.000 201 13-11% 65.81 4.2600 0,-0 0.000 201 13-11% 4 (See Notes) 26'111/2 120 57.649 fE(8'-ll%), mecl(26-4) 0.001280 -6.413 200 28-9 65.81 4.2600 62-3 0.080 51.316 Total(Pt) Route 24 214 13-0 65.81 4 (See Notes) 0-0 120 56.319 ..... Route 25•"•• Flow (q) from Route 48 fE(8'-11 %) 8-11% 0.001280 213 13-0 65.81 4.2600 8-11% 0.011 213 13-0 3 (See Notes) 215'6 120 56.330 4f1(17'-5%), 4fE(6-8%) 96-9 0.004711 -0.415 206 13-111/2 65.81 3.2600 312-3 1.471 206 13-111/2 3 28-0 120 57.386 0.004047 -0.000 204 13-11% 60.62 3.2600 28-0 0.113 204 13-111/2 5.19 3 (See Notes) 18'3 120 57.499 Flow (q) from Route 50 2fE(6'-8%) 13-5% 0.004711 -0.000 202 13-11% 65.81 3.2600 31 -8% 0.149 57.649 Total(Pt) Route 25 501 29'-3 325.94 4 5-21/2 120 43.958 Route 26..... Flow (q) from Route 3 0.004886 148 29-3 135.74 4.2600 5-2% 0.025 148 29'-3 4 (See Notes) 101 0 120 43.983 P0(26-4) 26-4 0.001394 150 29'-3 68.90 4.2600 36-4 0.051 150 29'-3 2 (See Notes) 141'5 120 44.034 21(12-31/2), P0(12-3%) 36-11 0.038331 0.217 149 28'-9 68.90 2.1570 178-4 6.836 (, © M.E.P.cAo, Inc. J AutoSPRINK 2018 v14.4.5.O verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 22 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as Fitting (Foot) Pt Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 149 28-9 6 - 10-0 120 51.087 0.000198 147 28'-9 68.90 6.3570 10,-U 0.002 147 28-9 66.84 6 10,-U 120 51.089 Flow (q) from Route 39 0.000696 145 28-9 135.74 6.3570 10,-U 0.007 145 28-9 66.47 6 10-0 120 51.096 Flow (q) from Route 45 0.001454 143 28'-9 202.21 6.3570 10,-U 0.015 51.110 Total(Pt) Route 26 122 29-3 2 (See Notes) 143-2 120 51.437 Route 27 ..... P0(12-31/2) 2T(12'-3Y2), P0(12-3%) 49-2% 0.006764 0.217 121 28-9 26.98 2.1570 192-5 1.301 52.956 Total(Pt) Route 27 126 29-3 2 (See Notes) 159-9 120 50.722 Route 28 ..... P0(12-31/2) 3T(12'-3%), 3fE(4'-3%), P0(12 -3%) 74-5% 0.006476 0.217 125 28-9 26.35 2.1570 234-2% 1.517 52.456 Total(Pt) Route 28 108 29-3 2 (See Notes) 138-1 120 52.651 Route 29 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.012390 0.217 107 28-9 37.42 2.1570 187-31/2 2.321 55.188 Total(Pt) Route 29 104 29'-3 43.48 4 (See Notes) 10,-U 120 52.721 Route 30 .... Flow (q) from Route I P0(26-4) 26-4 0.000724 102 29'-3 48.35 4.2600 36-4 0.026 102 29'-3 2 (See Notes) 138'1 120 52.748 2T(12'-3%), P0(12-3%) 36-11 0.019906 0.217 101 28-9 48.35 2.1570 175-0 3.483 56.448 Total(Pt) Route 30 132 29-3 2 (See Notes) J 141-61/2 120 49.250 Route 31 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49'-2% 0.012308 0.217 131 28-9 37.29 2.1570 190-9 2.348 51.815 Total(Pt) Route 31 © M.E.P.CAD, Inc. ill AutoSPRINK 2018 v14.4.5.0 verhead System, #5 - Rac 10/8/2021 11:01:48AM Page 23 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) c Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as n9Jh9 Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 118 29-3 2 (See Notes) 142-9 120 51.961 Route 32•"•• 2T(12-3%), P0(12-3%) 49-2% 0.006966 0.217 117 28-9 27.41 2.1570 191-11% 1.337 53.515 Total(Pt) Route 32 120 29-3 2 (See Notes) 143-6 120 51.718 •••• Route 33•"•• P0(12-3%) 2T(12'-3%), P0(12-3%) 4921/2 0.006709 0.217 119 28-9 26.86 2.1570 192-9 1.293 53.228 Total(Pt) Route 33 114 29-3 2 (See Notes) 140-11 120 52.337 Route 34 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.008302 0.217 113 28-9 30.14 2.1570 190-2 1.579 54.132 Total(Pt) Route 34 128 29-3 2 (See Notes) 142'2 120 50.293 Route 35 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.008974 0.217 127 28-9 - 31.43 2.1570 191-4% 1.718 52.227 Total(Pt) Route 35 124 29-3 2 (See Notes) 91-9% 120 51.105 Route 36 ..... P0(12-3%) T(12'-3%) 24-7% 0.004113 -1.387 300 32-5% 20.62 2.1570 116-5 0.479 300 32-5% 15.91 2 (See Notes) 51'1 120 50.197 Flow (q) from Route 49 T(12'-3%), P0(12-3%) 24-7% 0.011846 1.604 123 28-9 36.52 2.1570 75-8 0.896 52.697 Total(Pt) Route 36 134 29-3 2 (See Notes) I 141-1 120 48.479 Route 37 ..... mecT(12'-3%) 2T(12'-31/2), P0(12-3%) 49-21/2 0.015432 0.217 133 28-9 42.14 2.1570 190-31/2 2.937 51.632 Total(Pt) Route 37 112 29-3 2 (See Notes) I 139-8% 120 52.473 Route 38 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.009396 0.217 111 28-9 32.22 2.1570 I 188-111/2 1.775 54.465 Total(Pt) Route 38 , © M.E.P.CAD, Inc. AutoSPRINK 2018 04.4:5.0 verhead System, #5 Rac 10/812021 11:01:48AM Page 24 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) c Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 148 29-3 2 (See Notes) 140-11 120 43.983 Route 39 ..... P0(12-31/2) 2T(12'-3%), P0(12-3%) 4921/2 0.036233 0.217 147 28'-9 66.84 2.1570 190'-11/2 6.889 51.089 Total(Pt) Route 39 136 29-3 2 (See Notes) 14091/2 120 47.593 ••"• Route 4O ..... mecT(12'-3%) 2T(1231/2), P0(12-3%) 4921/2 0.019252 0.217 135 28-9 47.49 2.1570 190,-0 3.658 51.468 Total(Pt) Route 40 138 29'-3 2 (See Notes) J 140'6 120 46.583 Route 41 ..... mecT(12-3%) 2T(12'-3%), P0(12-3%) F 49-2% 0.023831 0.217 137 28-9 53.29 2.1570 1 189-8% 4.521 51.322 Total(Pt) Route 41 110 29-3 2 (See Notes) 138-6 120 52.577 ••• Route 42 ..... P0(12-3%) 2P0(12'-3%), T(12'-3%) 49-2% 0.010774 0.217 109 28-9 34.70 2.1570 187-9 2.023 54.817 Total(Pt) Route 42 116 29'-3 2 (See Notes) J 141-10 120 52.166 Route 43 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.007498 0.217 115 28-9 28.52 2.1570 1 1911-1 1.433 53.816 Total(Pt) Route 43 130 29-3 2 (See Notes) 141-91/2 120 49.805 ••"• Route 44 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49'-2% 0.010425 0.217 129 28-9 34.09 2.1570 191-0 1.991 52.013 Total(Pt) Route 44 146 29'-3 2 (See Notes) J 140'51/2 120 44.076 Route 45 ..... mecT(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.035866 0.217 145 28-9 66.47 2.1570 1 189-8 6.803 51.096 Total(Pt) Route 45 106 29-3 2 (See Notes) J 138-1 120 52.698 "•• Route 46 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) t 49-2% 0.014246 0.217 105 28-9 40.35 2.1570 187-3% 1 2.668 55.582 Total(Pt) Route 46 (,© M.E.p.cAD, Inc. III AutoSPRINK 2018 04.4.5.0 verhead System,-#5 - Rac 10/8/2021 11:01:48AM Page 25 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pfl and shown as ,2IIIp Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) Friction(Pf) 3102 30-71/2 33.60 2 13-0 T 120 41.683 Route 47 ..... Flow (q) from Route 19 0.008932 0.142 3101 30-3% 31.35 2.1570 13-0 0.116 41.942 Total(Pt) Route 47 215 29-3 4 (See Notes) 25-10 120 49.203 Route 48••••• fE(8'-l1%) 30-0% 0.001280 7.045 214 13-0 65.81 4.2600 55-101/2 0.071 56.319 Total(Pt) Route 48 301 29'-3 2 (See Notes) 95-10% 1 120 51.244 Route 49•"•• mecT(12'-3%) 2fT(10-5%), fE(4-3%) 37-6% 0.002545 -1.387 300 32-5% 15.91 2.1570 133-5 0.340 50.197 Total(Pt) Route 49 205 13-11% 5.19 1% (See Notes) 85-6 120 57.391 Route 50 ..... Flow (q) from Route 51 E(4-11%), P0(9-11) 14-10 0.001075 204 13-11% 5.19 1.6820 100-4% 0.108 57.499 Total(Pt) Route 50 206 13-111/2 3 (See Notes) 60-61/2 1 120 57.386 Route 51 ..... ff(17-54) P0(20-2) . 4fE(6-8%), 64'-6 0.000043 -0.000 205 13-11% 5.19 3.2600 125-0% 0.005 57.391 Total(Pt) Route 51 4 4-0 948.25 8 (See Notes) 2851'7 150 88.057 " Route 52..... Flow (q) from Route 1 4EE(11'-6), E(22'-l1%), 21(44' -8) 158-3 0.001251 2 -3-0 387.28 7.7100 3009-10 3.765 91 .822 Total(Pt) Route 52 , © M.E.P.CAD, Inc. ri AutoSPRINK 2018 v14.4.5.0 verhead System, #5 Rac 10/8/2021 11:01:48AM Page 26 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers Date: 10/8/2021 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) "C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 ( = Factor Schedule 40 Steel Pipe Inside Diameter ) Multiplying Factor 0.713 1,16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 900 Elbow FE 450 Elbow Eel 11140 Elbow Ee2 221/2° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap J,, ©M.E.P.CAD, Inc. ffl AutoSPRINK 2018 04.4.5.0 verhead System, #5- Rac 10/8/2021 11:01:48AM Page 27 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #3 - Rack Overhead System, #5 - Rack Sprinklers 150 45 30 15 Hydraulic Graph N 185 135 120 105 90 (0 a- 75 0 60 0 .iiiiiiitiii 1111111 I I I I I I I I I I I I I I I I I I I III I I I I I I I I I I I I I I I I I I I I I I I I 0550 1100 1650 2200 2750 3300 3850 4400 Flow - gpm k,@ M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 10/8/2021 11:01:41AM Hydraulic Calculations for Project Name: Thermo Fisher - Project Gold Rush Location: 5781 Van Allen Way, Carlsbad, CA 92008, Drawing Name: PRG_FP_WFP_PHASE 2 Calculation Date: 10/8/2021 Design Remote Area Number: Remote Area Location: Occupancy Classification Commodity Classification Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: 4 - Pre-action System Pre-action System Ordinary Group II Ordinary Group II 0.200gpm/1t2 1500.00ft2 (Actual 267.991t2) 104.00ft2 Pendent 3 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: I Type: 250.00 at Node: 21 Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 312.77 @ 48.497 Type of System: Pre-action Volume of Dry or PreAction System: 0.96ga1 Allowance at Source Hydrant Name of Contractor: Western Fire Protection Address: 13630 Danielson Street, Poway, CA 92-64 Phone Number: 858-513-4949 Name of designer: Grant Coito Authority Having Jurisdiction: City of Carlsbad Notes: Automatic peaking results Left: N/A Right: N/A (&© M.E.P.CAD, Inc. ;All 2018 04.4.5.0 4- Pre-action Sy 10/8/02110:55:19AM Page 1 HydrauIic Summary Job Number; 21-3573-02 Reoort Descriotion; Ordinary Grouo 11 (4 - Pre-action Svstem\ Job Job Number 21-3573-02 Design Engineer Grant Coito Job Name: Thermo Fisher - Project Gold Rush State CoroccauorvLicense Number Address t 5781 Van Allen Way API City of Carlsbad Add.. 2 Carlsbad, CA 92008 lob Sitelouitding Addtese 3 Drawing Name PRG_FP_WFP_PHASE 2 System Remote Area(s) Most Demanding Sprinkler Data 5.6 K-Factor 20.80 at 13.796 Osuupanoy Ordinary Group II Job Sutito 01050 Allowance At Source 0.00 Density 0.200gpm/ft2 Area otApplicalior 1500 .00f12 (Actual 267.99ft2) Additional Hose Supplies Node Flow(gpm) Hydrant At Node 21 250.00 Number Of Sprinklers Calculated 3 Couerage Per Sprinkler 104.00ft2 AutoPeok Resubs: Pressure For RemoteArea(s) Adjacent To Most Remote Area Total Hose Streams 250.00 System Flow Demand 312.77 Total ViNier Required (Including Hose Allowance) 312.77 Maximum Pressure Unbalance in Loops 0.000 Meolnrum Velocity Ab000 Ground 9.06 between nodes 401 and 402 Maximum Velocity Under Ground 2.95 between nodes 3 and 22 Volume capacity of PiNt Pipes 11879.84ga1 Volume capacity of Dry Pipes 0.96ga1 Supplies Node Name Hose Flow (gpm) Static (psi) Residual (psi) Flow (gpm) Available Total Demand (psi) @ (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 117.900 97.200 2700.00 117.516 312.77 48.497 69.020 Contractor Contractor Number 21-3537-02 Contact Name Grant Coito Contact Tile Designer Name ot Cont ractor Western Fire Protection Phone 858-513-4949 EutensEn Address I 13630 Danielson Street FAX 858-513-1322 Address 2 Poway, CA 92-64 E-mail grant@westernfireprotection.com Address 3 VuHb-Site ©M.E.P.CAD, Inc. R11 AutoSPRlNK2018v14.4.5.0 10/8/2021 10;55;50AM Page 1 l Sumrnary Of Outfiowing Devices - Job Number: 21-3573-02 Report Description: Ordinary Group 11 (4 - Pre-action System Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hydrant 21 250.00 250.00 0 46.038 c Sprinkler 4001 20.80 20.80 5.6 13.796 Sprinkler 4002 20.86 20.80 5.6 13.874 Sprinkler 4003 21.11 20.80 5.6 14.210 cf Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. M AutoSPRlNK 2018 04.4.5.0 10/8/2021 10:55:27AM Page 3 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 117.900 97.200 F 2700.00 117.516 312.77 48.497 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 135 28'-9 31.970 136 29-3 31.741 137 28-9 31.970 138 29-3 31.742 139 28-9 31.970 140 29'-3 31.742 141 28-9 31.970 142 29-3 31.743 143 28-9 31.970 144 29-3 31.743 145 28-9 31.970 146 29-3 31.743 147 28-9 31.970 148 29-3 31.743 149 28-9 31.970 150 29-3 31.743 200 28'-9 31.970 201 13-11% 38.382 202 13-11% 38.382 (,© M.E.P.CAD, Inc. 1AutoSPRINK 2018 04.4.5.0 10/8/2021 10:55:30AM Page 4 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (9pm) Notes 204 13111/2 38.381 205 13-11% 38.380 206 13111/2 38.380 213 13-0 38.784 214 13-0 38.784 215 29-3 31.739 300 32-5% 30.358 301 29-3 31.740 400 29-3 31.733 401 2941/2 27.291 402 3191/2 21.586 503 28-8 31.997 504 28-8 31.997 4101 31-9% 20.679 4102 31-9% 20.805 4103 31-9% 21.360 1 -3-0 Supply 48.497 312.77 21 2-0 Hydrant 46.038 250.00 4001 25-0 Sprinkler 13.796 20.80 4002 25-0 Sprinkler 13.874 20.86 4003 25-0 Sprinkler 14.210 21.11 2 4-0 48.494 3 -3-0 48.373 .,© M.E.P.CAD, Inc. gillAutoSPRINK 2018 04.4.5.0 10/8/2021 10:55:30AM Page 5 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 4 -3-0 48.373 5 -3-0 48.370 6 -5-0 46.647 7 -3-0 45.770 8 1-0 Gauge 44.034 22 4-0 48.235 100 28-9 31.993 101 28-9 31.984 102 29-3 31.749 103 28-9 31.982 104 29-3 31.749 105 28-9 31.981 106 29-3 31.749 107 28-9 31.979 108 29-3 31.749 109 28-9 31.978 110 29-3 31.748 111 28-9 31.977 112 29-3 31.748 113 28-9 31.976 114 29-3 31.747 115 28-9 31.975 116 29'-3 31.746 (,© M.E.P.CAD, Inc. AutoSPRlNK 2018 v14.4.5.0 10/8/2021 10:55:30AM Page 6 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 117 28-9 31.974 118 29-3 31.745 119 28-9 31.974 120 29-3 31.743 121 28-9 31.973 122 29-3 31.741 123 28-9 31.972 124 29-3 31.739 125 28-9 31.972 126 29-3 31.736 127 28-9 31.971 128 29-3 31.734 129 28-9 31.971 130 29-3 31.737 131 28'-9 31.971 132 29-3 31.739 133 28-9 31.970 134 29-3 31.740 F&,© M.E.P.CAD, Inc. IfflAutoSPRINK 2018 04.4.5.0 10/8/2021 10:55:30AM Page 7 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 4001 25-0 5.6 20.80 i (See Notes) 531,/2 100 13.796 Route I Sprinkler, 3E(1-5), P0(3-7), fd(37'-O) 44-10 0.196055 -2.947 4101 31-9% 20.80 1.0490 5011/2 9.830 4101 319 1/2 1% 6-6 100 20.679 0.019669 -0.002 4102 31-9% 20.80 1.6820 6-6 0.128 4102 31-9% 20.86 11/2 (See Notes) 3111/2 100 20.805 Flow (q) from Route 2 T(7'-O%) 7Q1 0.071092 -0.001 402 31-9% 41.66 1.6820 11-0 0.783 402 31-9% 21.11 1% (See Notes) 13'41/2 100 21.586 Flow (q) from Route 3 T(7-0%), 2E(3'-6%), fE(3'-1) 17-2% 0.151770 1.061 401 29-4% 62.77 1.6820 30-7 4.643 401 29-41/2 2 (See Notes) 48'8 100 27.291 BV(5'-3), DPV(-0.454), BV(7-4 %), 7fE(4'-31/2), mecT(12'-3%), C(12'-3%) 67-5 0.045197 0.047 400 29-3 62.77 2.1570 116-1 4.396 400 29-3 4 7-11% 120 31.733 0.000333 126 29-3 31.78 4.2600 7-11% 0.003 126 29-3 4 10-0 120 31.736 0.000287 124 29-3 29.31 4.2600 10-0 0.003 124 29-3 4 4-0 120 31.739 0.000254 301 29-3 27.46 4.2600 4-0 0.001 301 29-3 4 6-0 120 31.740 0.000228 122 29-3 25.92 4.2600 6-0 0.001 122 29-3 4 10-0 120 31.741 0.000191 120 29-3 23.52 4.2600 10-0 0.002 120 29-3 4 10-0 120 31.743 0.000158 118 29-3 21.22 4.2600 10-0 0.002 ,,© M.E.P.CAD, Inc. III AutoSPRlNK 2018 04.4.5.0 4- Pre-action System 10/8/2021 10:55:33AM Page 8 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) (psi) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 118 29-3 4 10-0 120 31.745 0.000129 116 29-3 19.00 4.2600 10,-0 0.001 116 29-3 4 10-0 120 31.746 0.000103 114 29-3 16.81 4.2600 10,-a 0.001 114 29-3 4 101-0 120 31.747 0.000079 112 29-3 14.62 4.2600 10,-a 0.001 112 29-3 4 101-0 120 31.748 0.000058 110 29'-3 12.41 4.2600 10'-O 0.001 110 29-3 4 10-0 120 31.748 0.000040 108 29-3 10.13 4.2600 10,-a 0.000 108 29-3 4 101-0 120 31.749 0.000025 106 29-3 7.78 4.2600 10,-0 0.000 106 29-3 4 10-0 120 31.749 0.000012 104 29'-3 5.34 4.2600 10,-a 0.000 104 29'-3 2 (See Notes) 138'1 120 31.749 P0(12-3%) 2T(12'-3%), P0(12-3%) 4921/2 0.000087 0.217 103 28'-9 2.56 2.1570 18731/2 0.016 103 28-9 57.43 6 10-0 120 31.982 Flow (q) from Route 5 0.000154 101 28-9 59.99 6.3570 10,-a 0.002 101 28-9 2.78 6 (See Notes) 29'l O% 120 31.984 Flow (q) from Route 16 2fE(12-7), TOR 26-2 0.000167 100 28'-9 62.77 6.3570 55-0 0.009 100 28-9 6 (See Notes) 314% 120 31.993 2E(17-7), BOR 35-2% 0.000167 12.030 8 11-0 62.77 6.3570 66-7 0.011 f, © M.E.P.CAD, Inc. III AutoSPRINK 2018 04.4.5.0 4- Pre-action System 10/8/2021 10:55:33AM Page 9 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pie-action System Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) 1 Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fithng/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as p naJ.tiwa s,l,ip Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 8 1-0 8 (See Notes) 9-10 140 44.034 LtE(22'-01/2), PIV(6-9%) 28-10 0.000033 1.734 7 -3-0 62.77 8.3900 38-8 0.001 7 -3-0 8 (See Notes) 139'2 150 45.770 E(22'-111/2), T(44'-8), 2LtE(16'- 7) 100-10 0.000043 0.867 6 -5-0 62.77 7.7100 240-0 0.010 6 -5-0 8 (See Notes) 12-0 140 46.647 T(59'4%), BFP(-2.586), 2LtE( 22-01/2) 103-6 0.000033 -0.867 5 4-0 62.77 8.3900 115-6 2.590 5 4-0 8 (See Notes) 209 150 48.370 LtE(16-7), T(44'-8) 61-3 0.000043 4 -3-0 62.77 7.7100 82-0 0.004 4 -3-0 8 (See Notes) 97'-4 150 48.373 EE(11'-6) 11-6 0.000000 3 -3-0 2.49 7.7100 108-91/2 0.000 3 4-0 250.00 8 (See Notes) 1901 11 150 48.373 Flow (q) from Route 4 LtE(16-7), GV(5'-l%) 21-8% 0.000567 2 4-0 252.49 7.7100 212-7% 0.121 2 4-0 60.28 8 (See Notes) 3'-1% 150 48.494 Flow (q) from Route 37 Water Supply 0.000843 1 4-0 312.77 7.7100 3-1% 0.003 0.00 48.497 Hose Allowance At Source Total(Pt) Route 1 1 312.77 4002 25-0 5.6 20.86 1 (See Notes) 5'3% 100 13.874 Route 2 Sprinkler, 3E(1'-5), P0(3-7), fd(37'-O) 44-10 0.197078 -2.949 4102 31-91/2 20.86 1.0490 50-1 1/2 9.880 20.805 Total(Pt) Route 2 4003 25-0 5.6 21.11 1 (See Notes) I 5'3% 100 1 14.210 Route ..... Sprinkler, 3E(1'-5), P0(3-7), fd(37'-O) 44-10 I 0.201490 -2.952 4103 31-9% 21.11 1.0490 50-1% I 10.103 ,,© M.E.P.cAD, Inc. III AutoSPRlNK 2018 04.4.5.0 4- Pre-action System 10/812021 10:55:33AM Page 10 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/20211 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fillings & . Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as nnJ2tl%IQ s,,i,ip 2 ____________________ Filling (Foot) Pf Friction Loss Per Unit i ' 'Si ' Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 4103 3191/2 1% (See Notes) 4'-0Y2 100 21.360 T(7'-01/2) 701/ 0.020214 0.001 402 31-91/2 21.11 1.6820 rii 0.224 21.586 Total(Pt) Route 3 21 2'-0 250.00 6 (See Notes) 3-0 140 46.038 Route 4••••• LtE(14-2) 14-2 0.001718 2.168 22 -3-0 250.00 6.2800 17-2 0.030 22 -3-0 6 (See Notes) 234h/2 150 48.235 GV(3'-10%), T(38'-11%) 2-10 0.002083 0.000 3 -3-0 250.00 5.8800 :66'3 0.138 48.373 Total(Pt) Route 4 202 13-11% 4.66 0-0 120 38.382 Route 5 ..... Flow (q) from Route 6 0.000010 -0.000 201 13-11% 4.66 4.2600 0-0 0.000 201 13-11% 4 (See Notes) 26-11 Y2 120 38.382 fE(8'-11%), mecT(26-4) 3531/2 0.000010 -6.413 200 28-9 4.66 4.2600 62'-3 0.001 200 28-9 11.84 6 0-5% 120 31970 . Flow (q) from Route 7 0.000014 137 28-9 16.50 6.3570 0.000 137 28-9 2.09 6 10-0 120 31.970 Flow (q) from Route 27 0.000018 135 28-9 18.59 6.3570 0.000 135 28-9 2.18 6 10-0 120 31.970 Flow (q) from Route 11 0.000022 133 28'-9 20.77 6.3570 10,-a 0.000 133 28-9 2.29 6 10-0 120 31.970 Flow (q) from Route 24 0.000026 131 28-9 23.06 6.3570 0.000 131 28-9 2.42 6 10-0 120 31.971 Flow (q) from Route 17 0.000032 129 28-9 25.48 6.3570 1-01-01 0.000 © M.E.P.CAD, Inc. III AutoSPRINK 2018 044.5.0 4-Pie-action System 10/8/2021 10:55:33AM Page 11 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as fl9J+iS WIr ________________ Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _________________ Friction(Pf) 129 28-9 2.63 6 10-0 120 31.971 Flow (q) from Route 30 0.000038 127 28-9 28.12 6.3570 10,-0 0.000 127 28-9 2.87 6 10,-U 120 31. 971 Flow (q) from Route 22 0.000045 125 28'-9 30.99 6.3570 10,-0 0.000 125 28'-9 2.47 6 101-0 120 31.972 Flow (q) from Route 14 0.000052 123 28'-9 33.45 6.3570 10,-0 0.001 123 28'-9 3.39 6 101-0 120 31. 972 Flow (q) from Route 23 0.000062 121 28'-9 36.85 6.3570 10,-0 0.001 121 28'-9 2.40 6 10-0 120 31. 973 Flow (q) from Route 13 0.000070 119 28'-9 39.25 6.3570 10'-0 0.001 119 28'-9 2.29 6 10-0 120 31. 974 Flow (q) from Route 20 0.000078 117 28'-9 41.54 6.3570 10-0 0.001 117 28-9 2.22 6 10,-U 120 31. 974 Flow (q) from Route 19 0.000086 115 28-9 43.77 6.3570 10-0 0.001 115 28-9 2.19 6 10,-U 120 31. 975 Flow (q) from Route 29 0.000094 113 28'-9 45.96 6.3570 10,-0 0.001 113 28'-9 2.19 6 101-0 120 31. 976 Flow (q) from Route 21 0.000102 111 28'-9 48.14 6.3570 10,-0 0.001 111 28'-9 2.22 6 10-0 120 31. 977 Flow (q) from Route 25 0.000 111 109 28-9 50.36 6.3570 10-0 0.001 109 28-9 2.27 6 10-0 120 31.978 Flow (q) from Route 28 - 0.000121 107 28-9 52.63 6.3570 ~_lo-o 0.001 f,©M.E.P.CAD, Inc. Jfl AutoSPRlNK 2018 v14.4.5.0 4- Pre-action System 10/8/2021 10:55:33AM Page 12 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pie-action System Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as 2 naJ2tisIO ,,liip Fitting (Foot) Pf Friction Loss Per unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 107 28-9 2.35 6 10-0 120 31.979 Flow (q) from Route 15 0.000131 105 28-9 54.99 6.3570 10,-0 0.001 105 28-9 2.45 6 10-0 120 31.981 Flow (q) from Route 32 0.000142 103 28-9 57.43 6.3570 101-0 0.001 31.982 Total(Pt) Route 5 214 13-0 4.66 4 (See Notes) 01- 120 38.784 Route ..... Flow (q) from Route 33 fE(8'-111/2) 8-11% 0.000010 213 13-0 4.66 4.2600 8-11% 0.000 213 13-0 3 (See Notes) 215'6 120 38.784 4fr(1 7'-S%), 4fE(6'-8%) 96-9 0.000035 -0.415 206 13-11% 4.66 3.2600 312-3 0.011 206 13-11% 3 28-0 120 38.380 0.000030 -0.000 204 13-11% 4.29 3.2600 28-0 0.001 204 13-11% 0.37 3 (See Notes) 18-3 120 38.381 Flow (q) from Route 35 2fE(6'-8%) 13-5% 0.000035 -0.000 202 13-11% 4.66 3.2600 31-8% 0.001 38.382 Total(Pt) Route 6 148 29'-3 3.92 4 (See Notes) 10-0 120 31.743 "•• Route 7•" Flow (q) from Route 8 P0(26-4) 26-4 0.000002 150 29-3 1.99 4.2600 36-4 0.000 150 29-3 2 (See Notes) 141'5 120 31.743 2T(12'-3%), P0(12-3%) 36-11 0.000054 0.217 149 28-9 1.99 2.1570 178-4 0.010 149 28-9 6 10-0 120 31.970 0.000000 147 28'-9 1.99 6.3570 10,-a 0.000 147 28-9 1.93 6 10-0 120 31.970 Flow (q) from Route 26 0.000001 145 28-9 3.92 6.3570 10,-a 0.000 © M.E.P.CAD, Inc. Auto SPRINK 2018 v144.5.0 4-Pie-action System 10/8/2021 10:55:33AM Page 13 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pfl and shown as . naJtisIa tiIi in Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _________________ Friction(Pf) 145 28-9 1.94 6 10-0 120 31.970 Flow (q) from Route 31 0.000002 143 28'-9 5.86 6.3570 10-0 0.000 143 28-9 1.96 6 10-0 120 31.970 Flow (q) from Route 9 0.000004 141 28-9 7.82 6.3570 10,-0 0.000 141 28'-9 1.99 6 10-0 120 31.970 Flow (q) from Route 18 0.000005 139 28-9 9.81 6.3570 10-0 0.000 139 28-9 2.03 6 9-6% 120 31 .970 ______ Flow (q) from Route 10 0.000008 200 28-9 11.84 6.3570 961/2 0.000 31.970 Total(Pt) Route 7 144 29-3 4 10-0 120 31.743 '•"Route8 ..... 0.000015 146 29-3 5.86 4.2600 10,-0 0.000 146 29'-3 4 10-0 120 31.743 0.000007 148 29-3 3.92 4.2600 10-0 0.000 31.743 Total(Pt) Route 8 140 29-3 4 10-0 120 31.742 "•• Route 9 ..... 0.000038 142 29-3 9.81 4.2600 10,-0 0.000 142 29'-3 4 10-0 120 31.743 0.000025 144 29'-3 7.82 4.2600 10,-0 0.000 144 29-3 _ 2 ________ (See Notes) 1402 120 31.743 mecT(12'-3%) 2T(12'-3%), P0(12-3%) 4921/2 0.000053 0.217 143 28-9 1.96 2.1570 189-4% 0.010 31.970 Total(Pt) Route 9 136 29-3 4 I 1 10-0 120 1 31.741 Route lO•"•• 0.000072 1 138 29-3 13.94 ____ 4.2600 0.001 M.E.P.CAD, Inc. LIU AutoSPRINK 2018 v1 4.4.5.0 4- Pre-action System 10/8/2021 10:55:33AM Page 14 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Equiv. Length (Foot) Length (Foot) C Factor ToTotal(Pt) Devices Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 138 29'-3 4 10-0 120 31.742 0.000054 140 29 -3 11.84 4.2600 10-0 0.001 140 29'-3 2 (See Notes) 140'3 120 31.742 mecT(12'-3%) 2T(12'-3%), P0(12-31/2) 49-2% 0.000057 0.217 139 28-9 2.03 2.1570 18951/2 0.011 31.970 Total(Pt) Route 10 134 29-3 18.40 4 10-0 120 31.740 ••••• Route ll ..... Flow (q) from Route 12 0.000095 136 29-3 16.12 4.2600 10,-a 0.001 136 29-3 2 (See Notes) 14091/2 120 31.741 mecT(12'-3%) 2T(12'-3%), P0(12-3%) 4921/2 0.000064 0.217 135 28-9 2.18 2.1570 190-0 0.012 31.970 Total(Pt) Route 11 132 29-3 4 0-9 120 31.739 Route 12..... 0.000184 215 29-3 23.06 4.2600 0,-9 0.000 215 29-3 4 9-3 120 31.739 0.000121 134 29-3 18.40 4.2600 9-3 0.001 31.740 Total(Pt) Route 12 122 29-3 2 (See Notes) 143'2 120 31.741 ••"• Route 13 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000077 0.217 121 28-9 2.40 2.1570 192-5 0.015 31 .973 Total(Pt) Route 13 126 29-3 2 (See Notes) 159-9 1 120 31.736 Route 14•••• P0(12-3%) 3T(12'-31/,.), 3fE(4-3%), P0(12' -31/2) 1 0.000081 0.217 125 28'-9 2.47 2.1570 234'-2/2 0.019 31 .972 Total(Pt) Rou=14 ] 108 29-3 2 (See Notes) 138-1 1 120 31.749 Route 15 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000074 0.217 107 28-9 2.35 2.1570 1187'-31/2 0.014 31.979 Total(Pt) Route 15 ,©M.E.P.CAD, Inc. IflAutoSPRINK 2018 04.4.5,0 4-Pie-action System 10/8/2021 10:55:33AM Page 15 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as nnJ.ti%Ia s,,Iiip Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 104 29'-3 2.56 4 (See Notes) 100 120 31.749 Route 16 ..... Flow (q) from Route I P0(26-4) 26-4 0.000004 102 29-3 2.78 4.2600 36-4 0.000 102 29-3 2 (See Notes) 1381 120 31.749 2T(12-3%), P0(12-3%) 36-11 0.000101 0.217 101 28-9 2.78 2.1570 175-0 0.018 31.984 Total(Pt) Route 16 400 29-3 31.78 4 2-0% 120 31.733 Route 17 ..... Flow (q) from Route 1 0.000318 128 29-3 30.99 4.2600 201/2 0.001 128 29-3 4 10-0 120 31.734 0.000265 130 29-3 28.12 4.2600 10-0 0.003 130 29'-3 4 10-0 120 31.737 0.000221 132 29-3 25.48 4.2600 10-0 0.002 132 29-3 2 (See Notes) 14161/2 120 31.739 P0(12-3%) 21(12-3%), P0(12-31/2) 49-2% 0.000078 0.217 131 28-9 2.42 2.1570 190-9 0.015 31.971 Total(Pt) Route 17 142 29-3 2 (See Notes) 140-1 120 31.743 Route 18 ..... mecl(12-3%) 2T(12-3%), P0(12-3%) 49-2% 0.000054 0.217 141 28-9 1.99 2.1570 189-4 0.010 31.970 Total(Pt) Route 18 118 29-3 2 (See Notes) I 142-9 120 31.745 Route 19..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000067 0.217 117 28-9 2.22 2.1570 191-11% 0.013 31.974 Total(Pt) Route 19 120 29-3 2 (See Notes) 143-6 120 31.743 Route 20 ..... P0(12-3%) 21(12-31/2), P0(12-3%) 4921/2 0.000071 0.217 119 28-9 2.29 2.1570 192-9 0.014 31.974 Total(Pt) Route 20 ,©M.E.P.CAD, Inc. AutoSPRINK2018v14.4.5.O 4-Pie-action System 10/8/2021 10:55:33AM Page 16 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Filling/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as aj,ti,,a ,,Ii.p Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 114 29-3 2 (See Notes) T 140-11 120 31.747 Route 21 P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000065 0.217 113 28'-9 2.19 2.1570 1 190-2 0.012 31.976 Total(Pt) Route 21 128 29'-3 2 (See Notes) 142'2 120 31.734 ••"• Route 22 ..... P0(12-3%) 2T(12-3Y2), P0(12-3%) 4921/2 0.000107 0.217 127 28-9 2.87 2.1570 191-4% 0.020 31.971 Total(Pt) Route 22 124 29-3 2 (See Notes) 91-9% 120 31.739 ••••• Route 23 ..... P0(12-3%) T(12'-3%) 24-7% 0.000048 -1.387 300 32-5% 1.85 2.1570 116-5 0.006 300 32-5% 1.54 2 (See Notes) 51,-I 120 30.358 Flow (q) from Route 34 T(12'-3%), P0(12-3%) 24'-7% 0.000146 1.604 123 28-9 3.39 2.1570 75-8 0.011 31.972 Total(Pt) Route 23 134 29-3 18.40 2 (See Notes) 141-1 120 31.740 Route 24 ..... mecT(12'-3%), Flow (q) from Route 12 2T(12'-3%), P0(12-3%) 49-2% 0.000070 0.217 ______________ 133 28-9 2.29 2.1570' 190-3% 0.013 31.970 Total(Pt) Route 24 112 29-3 2 (See Notes) 139'8% 120 31.748 •••Route25 ..... " P0(12-3%) 2T(12'-3%), P0(12-3%) 49'-2% 0.000066 0.217 111 28'-9 2.22 2.1570 1 188-11% 0.013 31.977 Total(Pt) Route 25 148 29'-3 3.92 2 (See Notes) J 140-11 120 31.743 Route 26 ..... P0(12-3%), Flow (q) from Route 8 2T(12'-31/2), P0(12-3%) 49'-2% 0.000051 0.217 ______________ 147 28-9 1.93 2.1570 190-1% 1 0.010 31.970 Total(Pt) Route 26 138 29-3 2 (See Notes) 140-6 120 31.742 Route 27 ..... mecT(12'-3%) 2T(12'-3%), P0(12-3%) 49'-2% 0.000060 0.217 137 28-9 2.09 2.1570 189-8% 0.011 31.970 Total(Pt) Route 27 (,©M.E.P.CAD, Inc. ill AutoSPRINK2O18v14.4.5.O 4- Pre-action System 10/8/2021 10:55:33AM Page 17 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) ___________ Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 110 29'-3 2 (See Notes) 138-6 120 31.748 Route 28".•• P0(12-3%) 2P0(12'-3%), T(12-3%) 49-2% 0.000070 0.217 109 28-9 2.27 2.1570 187-9 0.013 31.978 Total(Pt) Route 28 116 29-3 2 (See Notes) 141-10 120 31.746 Route 29 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49'-2% 0.000065 0.217 115 28-9 2.19 2.1570 191,-1 0.012 31.975 Total(Pt) Route 29 130 29-3 2 (See Notes) 141'9% 120 31.737 Route 30..... P0(12-3%) 2T(12-3%), P0(12-3%) 49'-2% 0.000091 0.217 129 28-9 2.63 ___ 2.1570 191-0 0.017 31.971 Total(Pt) Route 30 146 29-3 2 (See Notes) 140-51/2 120 31.743 Route 31 ..... mecl(12'-3%) 2T(12'-3%), P0(12-3%) 49-21/2 0.000052 0.217 145 28-9 1.94 2.1570 189 -8 0.010 31.970 Total(Pt) Route 31 106 29'-3 2 (See Notes) 138-1 120 31.749 Route 32.".. P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000080 0.217 105 28'-9 2.45 2.1570 187-3% 0.015 31.981 Total(Pt) Route 32 215 29'-3 4 (See 1 Notes) 1 25-10 120 31.739 .Route 33 ..... fT(21'-l) fE(8-111/2) 30'0% 0.000010 7.045 214 13-0 4.66 4.2600 55-101/2 0.001 38.784 Total(Pt) Route 33 301 29-3 2 (See Notes) 1 96-101/2 120 31.740 Route 34 ..... mecT(12-3%) 2fT(10'-5%), fE(4'-3%) 37-6% 0.000034 -1.387 300 32-5% 1.54 2.1570 133-5 0.005 30.358 Total(Pt) Route 34 205 13-11% 037 1% (See J Notes) 1 85-6 120 38.380 Route 35 ..... Flow (q) from Route 36 E(4'-ii%), P0(9-li) F 14-10 0.000008 204 13'-ii% L 0.37 1.6820 100-4% 0.001 38.381 Total(Pt) Route 35 © M.E.P.CAD, Inc. Jil AutoSPRINK 2018 04.4.5.0 4- Pre-action System 10/8/2021 10:55:33AM Page 18 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) Actual ID Length (Foot) (psi) directly to (PO and shown as (Foot) flaJ s,,I,ip ___2tiwa______________ 206 13-11% 3 (See 6061/2 120 38.380 Route 36•"•• fT(17-5%) 64-6 -0.000 Notes) 205 13-11% 0.37 3.2600 0.000000 4fE(6-8%), P0(20-2) 125-0% 0.000 38.380 Total(Pt) Route 36 4 -3-0 249 8 (See 2851-7 150 48.373 Route 37 ..... Flow (q) from Route I 158-3 Notes) 2 -3-0 60.28 7.7100 0.000040 4EE(11'-6), E(22-11%), 2T(44 3009-10 0.121 ________ -8) 48.494 Total(Pt) Route 37 , © M.E.P.CAD, Inc. AutoSPRlNK 2018 v14.4.5.0 . 4 -Pre-action System 10/8/2021 10:55:33AM Page 19 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: 4 - Pre-action System Date: 10/8/2021 I Equivalent Pipe Lengths of Valves and Fittings (C=120 only) IC Value Multiplier I Actual Inside Diameter 487 Value Of C 100 130 140 150 I \ =Factor Schedule 40 Steel Pipe Inside Diameter J Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve F 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. Ifi AutoSPRINK 2018 04.4.5.0 4- Pre-action System 10/8/2021 10:55:32AM Page 20 Hydraulic Graph Job Name: Thermo Fisher - Project Gold Rush N 1.85 Remote Area Number: 4 - Pre-action System 150 0550 1100 1650 2200 2750 3300 3850 4400 Flow - gpm ,© M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 10/8/2021 10:55:21AM 135 120 105 90 (0 0 CO :: 45 30 15 Hydraulic Calculations for Project Name: Thermo Fisher - Project Gold Rush Location: 5781 Van Allen Way, Carlsbad, CA 92008, Drawing Name: PRG_FP_WFP_PHASE 2 Calculation Date: 10/8/2021 Design Remote Area Number: Remote Area Location: Occupancy Classification: Commodity Classification: Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: #6 - COOLER/LAB AREA COOLER I LAB AREA Ordinary Group II Ordinary Group II 0.200gpm/ft2 2500.00ft2 (Actual 2527.14ft2) 120.00ft2 Pendent 35 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: I Type: 250.00 at Node: 21 Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 1178.31 @78.560 Type of System: Wet Volume of Dry or PreAction System: 0.96ga1 Allowance at Source Hydrant Name of Contractor: Western Fire Protection Address: 13630 Danielson Street, Poway, CA 92-64 Phone Number: 858-513-4949 Name of designer: Grant Coito Authority Having Jurisdiction: City of Carlsbad Notes: Automatic peaking results Left: N/A Right: N/A (© M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 #6 - COOLER / L I 10/8/202111:06:56AM Page 1 I Hydraulic Summary Job Number: 21-3573-02 Report Description: Ordinary Group II (#6 - COOLER / LAB AREA Job Job Number 21-3573-02 Design Engineer Grant Coito Job Name : Thermo Fisher - Project Gold Rush State CerbflAotiornlUoRnse Number Address I 5781 Van Allen Way AHJ City of Carlsbad Address 2 Carlsbad, CA 92008 Job Sitn/Butdirrg Address 3 Drawing Name PRG_FP_WFP_PHASE 2 System Remote Area(s) Most Demanding Sprirkior Data 5.6 K-Factor 24.00 at 18.367 Occupancy Ordinary Group II Job Suffix Hose Allowance At Source 0.00 Density 0.200gpm/ft2 Area otApplisetion 2500.00ft2 (Actual 2527.102) Additional 0000 Supplies Node Flow(gpm) Hydrant At Node 21 250.00 Number Of Sprinklers Calculated 35 Coverage Per Sprinkler 120.00ft2 AutoPeak Results . Pressure For Remote Area(s) Adjacent To Most Remote Area Total Hose Streams 250.00 System Flow Demand 1178.31 Total SHier Reqrdrnd (Including Hose Allowance) 1178.31 Maximum Pressure SnbaHrroo In Loops 0.000 Maximum Velocity Above Ground 23.64 between nodes 202 and 203 Maximum Velocity Under Ground 8.10 between nodes 1 and 2 Volume oapeoity of Wet Pipes 11879.84ga1 Volume sepeolty of Dry Pipes 0.96ga1 Supplies Node Name Hose Flow (gpm) Static (psi) Residual (psi) Flow (gpm) Available Total Demand (psi) @ (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 117.900 97.200 2700.00 113.435 I 1178.31 78.560 34.875 Contractor Conrracror Number 21-3537-02 Contact Name Grant Coito Conraor Title Designer Name of Contractor: Western Fire Protection Phone 858-513-4949 Extension Address r 13630 Danielson Street FAX 858-513-1322 Address 2 Poway, CA 92-64 Email grant@westernfireprotection.com Address 3 Web-Slra , © M.E.P.CADr Inc. Igi AutoSPRINK 2018 04.4.5.0 10/8/2021 11:07:27AM Page 1 1111 Summary Of Outfiowing Devices Job Number: 21-3573-02 Report Description: Ordinary Group II (#6 - COOLER! LAB AREA) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hydrant 21 250.00 250.00 0 74.862 Sprinkler 6001 27.86 24.00 5.6 24.745 Sprinkler 6002 27.24 24.00 5.6 23.667 Sprinkler 6003 25.44 24.00 5.6 20.630 Sprinkler 6004 25.85 24.00 5.6 21.306 Sprinkler 6005 25.67 24.00 5.6 21.018 Sprinkler 6006 25.99 24.00 5.6 21.542 Sprinkler 6007 26.08 24.00 5.6 21.691 Sprinkler 6008 26.32 24.00 5.6 22.098 Sprinkler 6009 26.58 24.00 5.6 22.531 Sprinkler 6010 26.79 24.00 5.6 22.880 Sprinkler 6011 25.79 24.00 5.6 21.205 Sprinkler 6012 26.05 24.00 5.6 21.646 Sprinkler 6013 26.38 24.00 5.6 22.196 Sprinkler 6014 24.60 24.00 5.6 19.303 Sprinkler 6015 24.73 24.00 5.6 19.499 c Sprinkler 6016 24.00 24.00 5.6 18.367 Sprinkler 6017 26.79 24.00 5.6 22.882 Sprinkler 6018 27.54 24.00 5.6 24.185 Sprinkler 6019 27.93 24.00 5.6 24.872 Sprinkler 6020 27.91 24.00 5.6 24.841 Sprinkler 6021 24.74 24.00 5.6 19.522 Sprinkler 6022 25.48 24.00 5.6 20.706 Sprinkler 6023 25.35 24.00 5.6 20.490 Sprinkler 6024 25.69 24.00 5.6 21.044 Sprinkler 6025 24.80 24.00 5.6 19.605 Sprinkler 6026 26.14 24.00 5.6 21.796 Sprinkler 6027 26.54 24.00 5.6 22.456 Sprinkler 6028 27.15 24.00 5.6 23.512 Sprinkler 6029 26.74 24.00 5.6 22.797 Sprinkler 6030 25.51 24.00 5.6 20.756 Sprinkler 6031 26.29 24.00 5.6 22.045 Sprinkler 6032 29.04 24.00 5.6 26.894 Sprinkler 6033 1 29.16 24.00 5.6 27.121 1 Sprinkler 6034 1 29.60 24.00 5.6 27.944 Sprinkler 6035 30.52 24.00 5.6 29.706 r-> Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. JAutoSPRlNK 2018 04.4.5.0 10!8!2021 11:07:05AM Page 3 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 117.900 97.200 1 2700.00 113.435 1178.31 78.560 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 4-0 Supply 78.560 1178.31 21 2-0 Hydrant 74.862 250.00 6001 10-0 Sprinkler 24.745 27.86 6002 10-0 Sprinkler 23.667 27.24 6003 10-0 Sprinkler 20.630 25.44 6004 10-0 Sprinkler 21.306 25.85 6005 10-0 Sprinkler 21.018 25.67 6006 10-0 Sprinkler 21.542 25.99 6007 10-0 Sprinkler 21.691 26.08 6008 10-0 Sprinkler 22.098 26.32 6009 10-0 Sprinkler 22.531 26.58 6010 10-0 Sprinkler 22.880 26.79 6011 10-0 Sprinkler 21.205 25.79 6012 10-0 Sprinkler 21.646 26.05 6013 10-0 Sprinkler 22.196 26.38 6014 10-0 Sprinkler 19.303 24.60 6015 10-0 Sprinkler 19.499 24.73 6016 10-0 Sprinkler 18.367 24.00 6017 10-0 Sprinkler 22.882 26.79 ,© M.E.P.CAD, Inc. 11 AutoSPRINK 2018 v14.4.5.0 10/8/2021 11:07:08AM Paqe 4 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6 - COOLER I LAB AREA Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 6018 10-0 Sprinkler 24.185 27.54 6019 10-0 Sprinkler 24.872 27.93 6020 10-0 Sprinkler 24.841 27.91 6021 10-0 Sprinkler 19.522 24.74 6022 10-0 Sprinkler 20.706 25.48 6023 10-0 Sprinkler 20.490 25.35 6024 10-0 Sprinkler 21.044 25.69 6025 10-0 Sprinkler 19.605 24.80 6026 10-0 Sprinkler 21.796 26.14 6027 10-0 Sprinkler 22.456 26.54 6028 10-0 Sprinkler 23.512 27.15 6029 10-0 Sprinkler 22.797 26.74 6030 10-0 Sprinkler 20.756 25.51 6031 10-0 Sprinkler 22.045 26.29 6032 10-0 Sprinkler 26.894 29.04 6033 10-0 Sprinkler 27.121 29.16 6034 10-0 Sprinkler 27.944 29.60 6035 10-0 Sprinkler 29.706 30.52 2 -3-0 78.530 3 -3-0 77.197 4 -3-0 76.817 5 -3-0 76.300 6 -5-0 70.977 (.,© M.E.P.CAD, Inc. AutoSPRlNK 2018 v14.4.5.0• .• 10/8/2021 11:07:08AM Page 5 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER I LAB AREA Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 7 -3-0 68.597 8 1-0 Gauge 66.679 22 -3-0 77.059 100 28-9 53.026 101 28-9 51.685 102 29-3 49.876 103 28-9 51.456 104 29-3 49.864 105 28-9 51.240 106 29-3 49.853 107 28-9 51.037 108 29-3 49.832 109 28-9 50.843 110 29-3 49.799 111 28-9 50.659 112 29-3 49.754 113 28-9 50.483 114 29-3 49.695 115 28-9 50.314 116 29-3 49.623 117 28-9 50.152 118 29-3 49.538 119 28'-9 49.995 ,© M.E.P.CAD, Inc. M1 AutoSPRlNK 2018 04.4.5.0 10/8/2021 11:07:08AM Page 6 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 120 29'-3 49.440 121 28-9 49.844 122 29-3 49.331 123 28-9 49.697 124 29-3 49.206 125 28'-9 49.556 126 29-3 49.069 127 28-9 49.418 128 29-3 48.920 129 28-9 49.285 130 29-3 48.758 131 28-9 49.157 132 29-3 48.581 133 28-9 49.034 134 29-3 48.569 135 28-9 48.914 136 29-3 48.570 137 28-9 48.797 138 29-3 48.571 139 28-9 48.792 140 29-3 48.571 141 28-9 48.792 142 29-3 48.571 FM,©M.E.P.CAD, Inc. 11AutoSPRINK201804.4.5.0 10/8/2021 11:07:08AM Paqe7 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6 - COOLER I LAB AREA Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 143 28-9 48.792 144 29-3 48.571 145 28-9 48.792 146 29-3 48.571 147 28-9 48.792 148 29-3 48.571 149 28-9 48.792 150 29-3 48.571 200 28-9 48.792 201 13.111/2 50.226 202 13.111/2 50.226 203 13.111/2 46.390 204 13.111/2 42.688 205 13.111/2 38.146 206 13111/2 37.920 207 13.111/2 32.750 208 13-11% 31.883 209 13-11% 31.876 210 13-11% 31.879 211 13-11% 31.955 212 13-11% 32.097 213 13-0 54.330 214 13-0 54.330 l&©M.E.P.CAD, Inc. AutoSPRlNK2018v14.4.5.0 10/8/2021 11:07:08AM Page 8 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 215 29-3 48.567 300 32-5% 47.923 301 29-3 49.257 503 28-8 48.825 504 28-8 48.825 6101 13-111/2 34.328 6102 13-11% 32.395 6103 13-11% 28.673 6104 13-11% 28.689 6105 13-11% 29.517 6106 13-11% 28.701 6107 13-111/2 28.907 6108 13-11% 29.674 6109 13-111/2 30.254 6110 13-11% 30.548 6111 13-111/2 28.392 6112 13-11% 28.844 6113 13-11% 29.604 6114 13-11% 24.078 6115 13-11% 24.343 6116 13-111/2 24.401 6117 11-6 22.702 6118 11-6 24.029 I'M,©M.E.P.CAD, Inc. AutoSPRINK2018v14.4.5.0 10/8/2021 11:07:08AM Paqe9 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER I LAB AREA Date: 10/8/2021 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 6119 11-6 24.729 6120 11-6 24.697 6121 13111/2 25.973 6122 13-11% 25.924 6123 13111/2 25.641 6124 13-11% 26.367 6125 13-111/2 26.378 6126 13111/2 27.342 6127 13-11% 28.206 6128 13-11% 29.595 6129 13-111/2 28.660 6130 13-11% 27.683 6131 13-11% 27.669 6132 13-111/2 36.075 6133 13-11% 36.388 6134 13111/2 37.518 6135 13111/2 39.937 6217 13-11% 24.866 6218 13-11% 25.413 6219 13-11% 26.950 6220 13-11% 26.143 ,© M.E.P.CAD, Inc. IMAutoSPRINK 2018 04.4.5.0 10/8/2021 11:07:08AM Page 10 Job Name: Thermo Fisher - Project Gold Rush - - - Remote Area Number: #6 - COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as naJti.a ualue Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 6016 10-0 5.6 24.00 i (See Notes) 8'6 120 18.367 Route I ..... Sprinkler, fd(25'-0), 2E(2'-O), P0(5-0) 34-0 0.182334 -1.716 6116 13111/2 24.00 1.0490 42'-6 7.750 6116 13-11% 4933 3-21/2 120 24.401 Flow (q) from Route 2 0.144437 6217 13111/2 73.33 1.6820 321/2 0.465 6217 13-11% 26.79 1% 2-1% 120 24.866 Flow (q) from Route 25 0.256949 6218 13-11% 100.12 1.6820 2-1% 0.547 6218 13-11% 27.54 1% (See Notes) 6'-2 120 25.413 Flow (q) from Route 28 P0(9-11) -11 0.402793 208 13-11% 127.66 1.6820 16-1 6.470 208 13-11% 131.41 + 28.86 3 12-0 120 31.883 Flow (q) from Route 4 and 12 0.072271 207 13-11% 287.93 3.2600 12-0 0.867 207 13-11% 03.17 + 105.7 3 (See Notes) 8'7% 120 32.750 Flow (q) from Route 5 and 9 fT(17'-5%) 17-5% 0.198248 206 13-11% 496.79 3.2600 26-1 5.170 206 13-11% 3 28-0 120 37.920 0.170311 -0.000 204 13-11% 457.63 3.2600 28-0 4.767 204 13-111/2 39.16 3 (See Notes) 11-11% 120 42.688 Flow (q) from Route 65 fE(6'-81/2) 6-8% 0.198248 -0.000 203 13-11% 496.79 3.2600 18-8 3.702 203 13-11% 118.33 3 (See Notes) 6-4 120 46.390 Flow (q) from Route 32 fE(6'8%) 6-8% 0.294350 202 13-111/2 615.12 3.2600 13-0% 3.836 202 13-11% 4 0-0 120 50.226 0.079985 -0.000 201 13-111/2 615.12 4.2600 0,-0 0.000 201 13-111/2 4 (See Notes) 261 11% 120 50.226 fE(8'-111/2), mecT(26'-4) 0.079985 -6.413 200 28-9 615.12 4.2600 62-3 4.978 , © M.E.P.CAD, Inc. AutoSPRINl( 2018 04.4.5.0 t6 - COOLER / LAB ARE? 10/8/2021 11:07:11AM Page 11 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) c Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as ________ Fitting (Foot) Pf Friction Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) _________________ Friction(Pf) 200 28-9 6.96 6 05h/2 120 48.792 Flow (q) from Route 37 0.011626 137 28-9 622.09 6.3570 O51/2 0.005 137 28'-9 1.92 6 10-0 120 48. 797 Flow (q) from Route 57 0.011693 135 28-9 624.01 6.3570 10-0 0.117 135 28'-9 7.72 6 10-0 120 914 Flow (q) from Route 41 0.011962 133 28-9 631.73 6.3570 10-0 0.120 133 28-9 11.07 6 10-0 120 034 Flow (q) from Route 54 0.012352 131 28-9 642.79 6.3570 10-0 0.124 131 28-9 13.51 6 10-0 120 49. 157 Flow (q) from Route 47 0.012837 129 28'-9 656.30 6.3570 10-0 0.128 129 28-9 12.48 6 10-0 120 49. 285 Flow (q) from Route 60 0.013292 127 28-9 668.79 6.3570 10-0 0.133 127 289 11.82 6 10-0 120 49. 418 Flow (q) from Route 52 0.013730 125 28-9 680.61 6.3570 10-0 0.137 125 28-9 10.37 6 10-0 120 49. 556 Flow (q) from Route 44 0.014120 123 28-9 690.98 6.3570 10-0 0.141 123 28-9 14.86 6 10-0 120 49. 697 Flow (q) from Route 53 0.014687 121 28'-9 705.84 6.3570 10-0 0.147 121 28'-9 12.13 6 10-0 120 49. 844 Flow (q) from Route 43 0.015157 10-0 119 28-9 717.97 6.3570 0.152 119 28'-9 13.01 6 10-0 120 49. 995 Flow (q) from Route 50 0.015669 117 28'-9 730.97 6.3570 10-0 0.157 (/, © M.EP.CAD, Inc. Ifl AutoSPRINK 2018 v14,4.5.0 t6 - COOLER! LAB ARE? 10/8/2021 11:07:11AM Page 12 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6 - COOLER I LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pfl 117 28-9 14.22 6 10-0 120 50.152 Flow (q) from Route 49 0.016237 . 115 28'9 745.20 6.3570 10'-0 0.162 115 28-9 15.70 6 10-0 120 50.314 Flow (q) from Route 59 0.016876 113 28'9 760.90 6.3570 10'-0 0.169 113 28-9 17.40 6 10-0 120 50. 483 Flow (q) from Route 51 0.017597 111 28-9 778.30 6.3570 10,-U 0.176 111 28-9 19.31 6 10-0 120 659 Flow (q) from Route 55 0.018413 109 28'-9 797.61 6.3570 10-0 0.184 109 28'-9 21.40 6 10-0 120 50.843 Flow (q) from Route 58 0.019337 107 28'-9 819.01 6.3570 10-0 0.193 107 28-9 23.58 6 10-0 120 037 Flow (q) from Route 45 0.020380 105 28-9 842.59 6.3570 10,-0 0.204 105 28'-9 25.85 6 10-0 120 51. 240 Flow (q) from Route 62 0.021552 103 28-9 868.44 6.3570 10-0 0.216 103 28-9 28.21 6 10-0 120 51. 456 Flow (q) from Route 7 0.022865 101 28-9 896.65 6.3570 10,-0 0.229 101 28-9 31.67 6 (See Notes) 29101/2 120 51.685 Flow (q) from Route 46 2fE(12'-7), TOR 25-2 0.024381 100 28-9 928.31 6.3570 55-0 1.341 100 28-9 6 (See Notes) 3141/2 120 53.026 2E(17'-7), BOR 3521/2 0.024381 12.030 8 1,-0 928.31 6.3570 66-7 1.623 8 1-0 8 Notes) 9-10 (See 140 66.679 LtE(22-0%), PlV(6'-9%) 28-10 0.004746 1.734 7 -3-0 928.31 8.3900 38-8 0.183 (M,©M.E.P.CAD, Inc. UAuto SPRINK2018v14.4.5.O t6-COOLER/LABAREI 10/8/2021 11:07:11AM Page 13 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6 - COOLER I LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 7 -3-0 8 (See Notes) 1392 150 68.597 E(27-11%),1(44-8), 2LtE(16'- 7) 100-10 0.006305 0.867 6 -5-0 928.31 7.7100 240-0 1.513 6 -5-0 8 (See Notes) 12'0 140 70.977 T(59-4%), BFP(-5.642), ME( 220h/2) 103-6 0.004746 -0.867 5 -3-0 928.31 8.3900 115-6 6.190 5 -3-0 8 (See Notes) 209 150 76.300 LtE(16-7), T(44'-8) 61-3 0.006305 4 -3-0 928.31 7.7100 82-0 0.517 4 -3-0 8 (See Notes) 97' 150 76.817 EE(11-6) 11-6 0.003499 3 -3-0 675.30 7.7100 108'-9/2 0.381 3 -3-0 250.00 8 (See Notes) 19011 150 77.197 Flow (q) from Route 36 LtE(16-7), GV(5'-l%) 2181/2 0.006267 2 -3-0 925.30 7.7100 21271/2 1.332 2 -3-0 253.02 8 (See Notes) 31% 150 78.530 Flow (q) from Route 67 Water Supply 0.009800 1 -3-0 1178.31 7.7100 311/2 0.031 0.00 78.560 Hose Allowance At Source Total(Pt) Route 1 1 1178.31 6014 101-0 5.6 24.60 1 (See Notes) 4'0 120 19.303 Route ..... Sprinkler, fd(25'-O), P0(5-0) 30-0 0.190912 -1.716 6114 13111/2 24.60 1.0490 34-0 6.491 6114 13111,4 11/2 13-10 120 24.078 0.019153 6115 13111/2 24.60 1.6820 13-10 0.265 6115 13-11%24.73 1% 0-10 120 24.343 Flow (q) from Route 3 0.069370 6116 13111,4 49.33 1.6820 0-10 0.058 24.401 Total(Pt) Route 2 © M.E.P.CAD, Inc. I.M AutoSPRINK 2018 v14.4.5.0 /6 - COOLER ILAB AREI 10/8/2021 11:07:11AM Page 14 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6 - COOLER / LAB AREA Date: 10/8/2021 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pf) and shown as (Foot) 2 naJ.tiva u2lirn 6015 10-0 5.6 24.73 1 (See 40h, T 120 19.499 Route 3 ..... Sprinkler, 30-0 -1.716 Notes) 6115 13-11% 24.73 1.0490 0.192704 fd(25'-O), P0(5-0) 34 0 h/2 6.560 24.343 Total(Pt) Route 3 6021 10-0 5.6 24.74 1 (See 8'-4 120 19.522 Route 4•••• Sprinkler, 34-0 -1.716 Notes) 6121 13-11% 24.74 1.0490 0.192915 fd(25'-O), 2E(2'-O), P0(5-0) 42-4 8.167 6121 13-11% 50.83 111/2 120 25.973 Flow (q) from Route 6 0.152710 6220 13-11% 75.57 1.6820 0.170 6220 13-11% 27.91 1% 2-11% 120 26.143 Flow (q) from Route 30 0.273150 6219 13-11% 103.48 1.6820 2-11% 0.807 6219 13-111/2 27.93 11/2 (See 1'8% 120 26.950 Flow (q) from Route 31 9-11 Notes) 208 13-11% 131.41 1.6820 0.424971 P0(9-11) 11-71/ 4.933 31.883 Total(Pt) Route 4 6025 10-0 5.6 24.80 i (See 7-10 120 19.605 Route ..... Sprinkler, 36-0 -1.716 Notes) 6125 13-111/2 24.80 1.0490 0.193669 fd(25'-O), 3E(2'-O), P0(5-0) 43-10 8.489 6125 13-11% 25.69 1% 13-4 120 26.378 Flow (q) from Route 11 0.072398 6126 13-111/2 50.48 1.6820 13-4 0.964 6126 13-11% 26.14 1% 6-6 120 27.342 Flow (q) from Route 17 0.156678 6127 13-11% 76.63 1.6820 5'-6 0.864 6127 13-111/2 26.54 1% (See 610 120 28.206 Flow (q) from Route 21 -11 Notes) 207 13-111/2 103.17 1.6820 0.271597 P0(9-11) 16-9 4.544 32.750 Total(Pt) Route 5 6023 10-0 5.6 25.35 i (See 4-0% J 120 20.490 1 Route ..... Sprinkler, 30'0 -1.716 Notes) 6123 13-111/2 25.35 1.0490 0.201740 I fd(25'-O), P0(5-0) 34-0% 6.867 ,© M.E.P.CAD, Inc. AutoSPRINK.2018 v14.4.5.0 t6 - COOLER / LAB ARE? 1018/2021 11:07:11AM Page 15 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 6123 13-11% 1% 14-0 120 25.641 0.020239 6122 13-11% 25.35 1.6820 14-0 0.283 6122 13-11% 25.48 1% 0-8 120 25.924 Flow (q) from Route 8 0.073319 6121 13-111/2 50.83 1.6820 0-8 0.049 25.973 Total(Pt) Route 6 6003 10-0 5.6 25.44 i (See Notes) 4-1 120 20.630 ••••• Route 7 Sprinkler, E(2'-O), P0(5-0), fd(37'-O) 44-0 0.203017 -1.716 6103 13-11% 25.44 1.0490 48-1 9.759 6103 13-11% 1% 0-9% 120 28.673 0.020367 6104 13-11% 25.44 1.6820 0-9% 0.016 6104 13-11% 25.85 1% 111-1 120 28.689 Flow (q) from Route 13 0.074533 6105 13-11% 51.28 1.6820 11,-i 0.828 6105 13111/2 25.67 1% (See Notes) 6'S% 120 29.517 Flow (q) from Route 10 pO(911) 91-11 0.157922 212 13-11% 76.96 1.6820 16-4 2.581 212 13'-11'/2 181.13 3 501/2 120 32.097 Flow (q) from Route 14 0.059029 -0.000 6102 13il1/2 258.09 3.2600 5-0% 0.298 6102 13il1/2 27.24 3 (See Notes) 91 9 120 32.395 Flow (q) from Route 27 ff(17'5%) 17-5% 0.071070 6101 13-11% 285.33 3.2600 27-2% 1.933 6101 13-11% 27.86 3 (See Notes) 161'0 120 34.328 Flow (q) from Route 29 4fE(6'-8%), 2fT(17'-S%), fE(9'-i 70--l1% 0.084437 0.415 213 13-0 313.19 3.2600 231-11% 19.586 213 13-0 4 . 0-0 120 54.330 0.022944 214 13-0 313.19 4.2600 0,-0 0.000 214 13-0 4 (See Notes) 2610 120 54.330 fE(8'-ii%), fT(21'-1) 30-0% 0.022944 -7.045 215 29-3 313.19 4.2600 55-10% 1.282 ,©M.E.P.CAD, Inc. III AutoSPRINK 2018 v14.4,5.0 t6- COOLER / LAB ARE/ 10/8/2021 11:07:11AM Page 16 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses when applicable, are added directly to (P0 and shown as p nnJ2tmsIa ssIt.a Fitting (Foot) Pf Friction Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 215 29-3 4 0-9 120 48.567 0.019336 132 29-3 285.52 4.2600 0.015 132 29-3 4 10-0 120 48.581 0.017677 130 29-3 272.01 4.2600 0.177 130 29-3 4 10-0 120 48.758 0.016206 128 29-3 259.53 4.2600 10-0 0.162 128 29-3 4 10-0 120 48.920 0.014866 101-0 126 29-3 247.70 4.2600 0.149 126 29-3 4 10-0 120 49.069 0.013736 124 29-3 237.34 4.2600 0.137 124 29-3 4 4-0 120 49.206 0.012784 301 29-3 228.30 4.2600 41-0 0.051 301 29-3 4 6-0 120 49.257 0.012187 122 29-3 222.48 4.2600 6-0 0.073 122 29-3 4 10-0 120 49.331 0.010987 120 29'-3 210.35 4.2600 0.110 120 29-3 4 10-0 120 49.440 0.009763 118 29-3 197.34 4.2600 0.098 118 29-3 4 10-0 120 49.538 0.008501 116 29-3 183.12 4.2600 1 101-0 0.085 116 29-3 4 10-0 120 49.623 1 0._0 0.007202 114 29-3 167.42 I 4.2600 r 0.072 , © M.E.P.CAD, Inc. Jil AutoSPRINK 2018 04.4.5.0 /6-COOLER/ LABAREJ 10/8/2021 11:07:11AM Page 17 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pfl and shown as najtiva uI..n Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 114 29-3 4 101-0 120 49.695 0.005879 112 29'-3 150.02 4.2600 10,-a 0.059 112 29-3 4 101-0 120 49.754 0.004556 110 29-3 130.71 4.2600 10,-a 0.046 110 29'-3 4 10-0 120 49.799 0.003273 108 29-3 109.31 4.2600 10,-a 0.033 108 29'-3 4 101-0 120 49.832 0.002088 106 29-3 85.73 4.2600 10-0 0.021 106 29-3 4 10-0 120 49.853 0.001075 104 29'-3 59.87 4.2600 10,-a 0.011 104 29'-3 2 (See Notes) 138-1 120 49.864 P0(1 2-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.007344 0.217 103 28-9 28.21 2.1570 187-3% 1.375 51.456 Total(Pt) Route 7 6022 10,-a 5.6 25.48 1 (See Notes) 1 4-0% I 120 20.706 "'• Route 8"... Sprinkler, fd(25'-0), P0(5-a) F 30-0 0.203710 -1.716 6122 13-11% 25.48 1.0490 I 34'-0/ 6.934 25.924 Total(Pt) Route 8 6030 101-0 5.6 25.51 1 (See Notes) 8-4 120 20.756 " Route 9 Sprinkler, fd(25'-O), 2E(2'-O), P0(5-a) 34-0 0.204166 -1.716 6130 13-11% 25.51 1.0490 42-4 8.643 6130 13-11% 26.29 1% 12-10% 120 27.683 Flow (q) from Route 18 0.075943 6129 13-11% 51.81 1.6820 12-10% 0.977 6129 13-11% 26.74 1% 5-8% 120 28.660 Flow (q) from Route 23 0.163998 6128 13-11% 78.54 1.6820 58h/2 0.935 © M.EP.CAD, Inc. AutoSPRINIK 2018 v14.4.5.0 t6 - COOLER / LAB AREt 10/8/2021 11:07:11AM Page 18 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as flJ+i SIfl9 Fitting (Foot) Pf Friction Loss Per unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 6128 13-11% 27.15 1% (See Notes) 1'2% 120 29.595 Flow (q) from Route 26 Pop'-11) 0.284054 207 13-11% 105.70 1.6820 11-1% 3.155 32.750 Total(Pt) Route 9 6005 10-0 5.6 25.67 1 (See Notes) 1 F 120 21.018 Route 10 ..... Sprinkler, 2E(2'-O), P0(5-0), fd(37-0) 46-0 0.206547 -1.716 6105 13-111/2 25.67 1.0490 49-5% 10.215 29.517 Total(Pt) Route 10 6024 10-0 5.6 25.69 1 (See Notes) 4-0% 120 21.044 ••••• Route ll ..... Sprinkler, fd(25-0), P0(5-0) 30-0 0.206788 -1.716 6124 13-11% 25.69 1.0490 34-0% 7.039 6124 13-11% 1% 0-6 120 26.367 0.020746 6125 13-11% 25.69 1.6820 0-6 0.010 26.378 Total(Pt) Route 11 6011 10-0 5.6 25.79 i (See Notes) 0-9 120 21.205 Route 12 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.208250 -1.716 6111 13-11% 25.79 1.0490 42-9 8.903 6111 13-111/2 1% (See Notes) 111 9 120 28.392 2E(4'-11%) 91-11 0.020892 6112 13-11% 25.79 1.6820 21-7% 0.452 6112 13-11% 26.05 11/2 10-0 120 28.844 Flow (q) from Route 15 0.076039 6113 13-11% 51.84 1.6820 10-0 0.760 6113 13-111/2 26.38 1% (See Notes) 4'0% 120 29.604 Flow (q) from Route 20 po(9'il) 9-11 0.162768 209 13-11% 78.22 1.6820 13-11% 2.272 209 13-111/2 3 6-4% 120 31.876 0.001025 -0.000 208 13-11% 28.86 3.2600 6-4% 0.007 31.883 Total(Pt) Route 12 (,.©M.E.P.CAD, Inc. AutoSPRINK201804.4.5.0 t6- COOLER / LAB ARE 10/8/2021 11:07:11AM Page 19 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) ___________ Pf Friction Loss Per unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 6004 10-0 5.6 25.85 1 (See Notes) 1-6 120 21.306 Route 13 ..... Sprinkler, P0(5-0), fd(37'-0) 42-0 0.209167 -1.716 6104 13-111/2 25.85 1.0490 43'-6 9.099 28.689 Total(Pt) Route 13 6006 10-0 5.6 25.99 i (See Notes) 0-0 120 21.542 ••••• Route 14 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.211311 -1.716 6106 131i1/2 25.99 1.0490 42-0 8.875 6106 13-11% 11/2 9-81/2 120 28.701 0.021200 6107 13-111/2 25.99 1.6820 98h/2 0.205 6107 13-11% 26.08 11/2 10-0 120 28.907 Flow (q) from Route 16 0.076668 6108 13-111/2 52.07 1.6820 10,-U 0.767 6108 13-11% 26.32 1% (See Notes) 4'0% 120 29.674 Flow (q) from Route 19 P0(9-11) 91-11 0.163435 211 13-11% 78.40 1.6820 13-11% 2.281 211 13-11% 102.74 3 4-8 120 31.955 Flow (q) from Route 22 0.030661 212 13-11% 181.13 3.2600 4-8 0.143 32.097 Total(Pt) Route 14 6012 101-0 5.6 26.05 1 (See Notes) 01-0 120 21.646 Route 15 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.212248 -1.716 6112 13-11% 26.05 1.0490 42-0 8.914 28.844 Total(Pt) Route 15 6007 10-0 5.6 26.08 1 (See Notes) 01-0 120 21.691 Route l6..... Sprinkler, P0(5-0), fd(37'-U) 42-0 0.212661 -1.716 6107 13-11% 26.08 1.0490 42-0 8.932 28.907 Total(Pt) Route 16 6026 101-0 5.6 26.14 1 (See Notes) 4-0 120 21.796 ••••• Route 17 ..... Sprinkler, fd(260), P0(5-U) 30-0 0.213608 -1.716 6126 13-111/2 26.14 1.0490 34-0 7.263 27.342 Total(Pt) Route 17 , © M,E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 /6 - COOLER / LAB ARE. 10/8/2021 11:07:11AM Page 20 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6 - COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as pegatffiva km Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 6031 10-0 5.6 26.29 1 (See Notes) 4'0 120 22.045 Route 18 ..... Sprinkler, fd(25'-0), P0(5-0) 30-0 0.215869 -1.716 6131 13-11% 26.29 1.0490 34-0 7.340 6131 13-111/2 1% 0-8 120 27.669 0.021657 6130 13-11% 26.29 1.6820 0-8 0.014 27.683 Total(Pt) Route 18 6008 101-0 5.6 26.32 1 (See Notes) o'li% 120 22.098 Route 19 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.216349 -1.716 6108 13111/2 26.32 1.0490 42-11% 9.291 29.674 Total(Pt) Route 19 6013 10-0 5.6 26.38 1 (See Notes) 0-0 120 22.196 ••••• Route 2O ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.217239 -1.716 6113 13-11% 26.38 1.0490 42-0 9.124 29.604 Total(Pt) Route 20 6027 10-0 5.6 26.54 1 (See 1 Notes) 4'O 120 22.456 Route 21 ..... Sprinkler, fd(25'-O), P0(5-0) 30-0 0.219590 -1.716 6127 13-11% 26.54 1.0490 I 34-0 7.466 28.206 Total(Pt) Route 21 6009 10-0 5.6 26.58 1 (See Notes) 0-10% 120 22.531 Route 22 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.220267 -1.716 6109 13-111/2 26.58 1.0490 42-10 9.439 6109 13-111/2 11/2 13-3% 120 30.254 0.022098 6110 13-11% 26.58 1.6820 13-3% 0.293 6110 13-11% 26.79 (See Notes) 6'8% 120 30.548 Flow (q) from Route 24 P0(9-11) 91-11 0.080233 210 13-111/2 53.37 1.6820 16-7 1.331 210 13-11% 49.37 3 7-0% 120 31.879 Flow (q) from Route 63 0.010739 0.000 211 13-111/2 102.74 3.2600 701/2 0.076 31.955 Total(Pt) Route 22 , © ME. P. CAD, Inc. III AutoSPRINK 2018 04.4.5.0 /6 - COOLER! LAB ARE? 10/8/2021 11:07:11AM Page 21 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER I LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pfl and shown as n91fis, s,In Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 6029 10-0 5.6 26.74 1 (See Notes) 4-0% 120 22.797 Route 23 ..... Sprinkler, fd(25'-0) P0(5-0) 30-0 0.222666 -1.716 6129 13111/2 26.74 1.0490 34-0% 7.580 28.660 Total(Pt) Route 23 6010 10-0 5.6 26.79 1 (See Notes) 0-0 120 22.880 ••••• Route 24 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.223421 -1.716 6110 13-11% 26.79 1.0490 42-0 9.384 30.548 Total(Pt) Route 24 6017 10-0 5.6 26.79 1 (See Notes) 1-6 100 22.882 .Route 25 ..... Sprinkler 0.313075 -0.650 6117 11-6 26.79 1.0490 1-6 0.470 6117 11-6 i (See Notes) 5'5% 120 22.702 2E(2'-O), P0(5-0) '-o 0.223441 -1.066 6217 13111/2 26.79 1.0490 14-5% 3.230 24.866 Total(Pt) Route 25 6028 10-0 5.6 27.15 1 (See Notes) 4-0% 120 23.512 ••"• Route 26 ..... Sprinkler, fd(25'-0), P0(5-0) 30-0 0.229120 -1.716 6128 13-11% 27.15 1.0490 34-01/2 7.799 29.595 Total(Pt) Route 26 6002 10-0 5.6 27.24 1 (See Notes) 331,/2 120 23.667 ••••• Route 27••.• Sprinkler, P0(5-0), fd(37'-O) 42-0 0.230519 -1.716 6102 13111/2 27.24 1.0490 45-31/2 10.444 32.395 Total(Pt) Route 27 6018 ' 10-0 5.6 27.54 i (See Notes) 1'6 100 24.185 Route 28 ..... Sprinkler 0.329522 -0.650 6118 11-6 27.54 1.0490 1-6 0.494 6118 11-6 1 (See Notes) 3'5 120 24.029 E(2'-O), P0(5-0) 0.235180 -1.066 6218 13-11% 27.54 1.0490 10-5 2.450 25.413 Total(Pt) Route 28 6001 10-0 5.6 27.86 1 (See Notes) 3-0% T• 120 24.745 •••" Route 29•"•. Sprinkler, E(2'-O), P0(5-0), fd(37'-O) 44-0 1 0.240216 -1.716 6101 13-111/2 27.86 1.0490 47-0% 11.299 © M.E.P.CAD, Inc. i AutoSPRINK 2018 04.4.5.0 t6 - COOLER / LAB ARES 10/8/2021 11:07:11AM Page 22 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER I LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as n9+i,, -4-8 1 Fitting (Foot) Pf Friction Loss Per unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 34.328 Total(Pt) Route 29 6020 10-0 5.6 27.91 i (See Notes) 1-6 100 24.841 30 ..... Sprinkler . Route 0.337785 -0.650 6120 11-6 27.91 1.0490 1-6 0.507 6120 11-6 1 (See Notes) 3'-5 120 24.697 E(2'-O), P0(5-U) 7-0 0.241077 -1.066 6220 1311h/2 27.91 1.0490 10-5 2.511 26.143 Total(Pt) Route 30 6019 10-0 5.6 27.93 1 (See Notes) 1-6 100 24.872 ••"• Route 31 ..... Sprinkler 0.338171 -0.650 6119 11-6 27.93 1.0490 1-6 0.507 6119 11-6 1 (See Notes) 4'-7Y2 120 24.729 2E(2'-O), P0(5-U) 91-0 0.241352 -1.066 6219 13111/2 27.93 1.0490 13'-71/2 3.287 26.950 Total(Pt) Route 31 6032 101-0 5.6 29.04 1 (See Notes) 01-0 120 26.894 ••••• Route 32 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.259453 -1.716 6132 1311h/2 29.04 1.0490 42-0 10.897 6132 13-11% 1/2 12-0 120 36.075 0.026029 6133 13-11% 29.04 1.6820 12-0 0.312 6133 13111/2 29.16 1% 12-0 120 36.388 Flow (q) from Route 33 0.094202 6134 13-111/2 58.21 1.6820 12-0 1.130 6134 13-111/2 29.60 1% 12-0 120 37.518 Flow (q) from Route 34 0.201567 6135 13-111/2 87.81 1.6820 12-0 2.419 6135 13-11% 30.52 11/2 (See Notes) 3'7 120 39.937 Flow (q) from Route 35 EE(4--111/2),, P0(9-11) 14-10 0.350030 1 203 13-11% 118.33 1.6820 18-5 6.453 46.390 Total(Pt) Route 32 ,,©M.E.P.CAD, Inc. lilAutoSPRINK2018v14.4.5.O /6- COOLER / LAB ARE/ 10/8/2021 11:07:11AM Page 23 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as *,,Iiip Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pt) 6033 10-0 5.6 29.16 i (See Notes) 0-0 120 27.121 Route 33 ..... Sprinkler, P0(5-0), fd(37-O) 42-0 0.261480 -1.716 6133 13-11% 29.16 1.0490 42-0 10.982 36.388 Total(Pt) Route 33 6034 10-0 5.6 29.60 i (See Notes) 0-0 120 27.944 Route 34 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.268808 -1.716 6134 13111/2 29.60 1.0490 42-0 11.290 37.518 Total(Pt) Route 34 6035 10-0 5.6 30.52 1 (See Notes) T 0-0 120 29.706 ••••• Route 35 ..... Sprinkler, P0(5-0), fd(37'-O) 42-0 0.284449 -1.716 6135 13-11% 30.52 1.0490 1 42-0 11.947 39.937 Total(Pt) Route 35 21 2-0 250.00 6 (See Notes) 3-0 140 74.862 Route 36 ..... LtE(14-2) 14-2 0.001718 2.168 22 -3-0 250.00 6.2800 17-2 0.030 22 -3-0 6 (See Notes) 23'4% 150 77.059 GV(3'-lO%), T(38-11%) 42-10 0.002083 0.000 3 -3-0 250.00 5.8800 66-3 0.138 77.197 Total(Pt) Route 36 148 29-3 2.30 4 (See Notes) 10-0 120 48.571 Route 37 ..... Flow (q) from Route 38 P0(26-4) 26-4 0.000001 150 29-3 1.17 4.2600 36-4 0.000 150 29-3 2 (See Notes) 141'5 120 48.571 2T(12'-3%), P0(12-3%) 36-11 0.000020 0.217 149 28-9 1.17 2.1570 178-4 0.004 149 28-9 6 10-0 120 48.792 0.000000 147 28-9 1.17 6.3570 10,-0 0.000 147 28-9 1.13 6 10-0 120 48.792 Flow (q) from Route 56 0.000000 145 28-9 2.30 6.3570 10,-0 0.000 , © M.E.P.CAD, Inc. III AutoSPRINK 2018 04.4.5.0 t6 - COOLER / LAB ARES 10/8/2021 11:07:11AM Page 24 -Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6 - COOLER I LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fillings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Filling/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(PO 145 28-9 1.14 6 10-0 120 48.792 Flow (q) from Route 61 0.000001 143 28'-9 3.44 6.3570 10-0 0.000 143 28-9 1.15 6 10,-a 120 48. 792 Flow (q) from Route 39 0.000001 141 28'-9 4.60 6.3570 10,-0 0.000 141 28-9 1.17 6 10-0 120 48.792 Flow (q)from Route 48 0.000002 139 28-9 5.77 6.3570 10,-a 0.000 139 28-9 1.20 6 9-6% 120 48.792 Flow (q) from Route 40 0.000003 200 28'-9 6.96 6.3570 9-6% 0.000 48.792 Total(Pt) Route 37 144 29-3 4 101-0 120 48.571 •••• Route 38 ..... 0.000005 146 29-3 3.44 4.2600 10,-a 0.000 146 29'-3 4 10-0 120 48.571 0.000003 148 29-3 2.30 4.2600 10,-0 0.000 48.571 Total(Pt) Route 38 140 29-3 4 10-0 120 48.571 ••"• Route 39 ..... 0.000014 142 29-3 5.77 4.2600 10,-a 0.000 142 29-3 4 10-0 120 48.571 0.000009 144 29-3 4.60 4.2600 10,-a 0.000 144 29-3 2 (See Notes) 140'2 120 48.571 mecT(12'-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000020 0.217 143 28'-9 1.15 2.1570 189-4% 0.004 48.792 Total(Pt) Route 39 136 29'-3 4 10-0 120 1 48.570 Route 40 ..... 0.000032 138 29'-3 8.88 4.2600 10,-a I 0.000 , © M.E.P.CAD, Inc. ill AutoSPRINK 2018 04.4.5.0 /6 - COOLER / LAB ARE? 10/8/2021 11:07:11AM, Page 25 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) ___________ Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 138 29-3 4 10-0 120 48.571 0.000020 140 29-3 6.96 4.2600 10,-a 0.000 140 29-3 2 (See Notes) 140'3 120 48.571 mecl(12'-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000021 0.217 139 28-9 1.20 2.1570 189'-5/2 0.004 48.792 Total(Pt) Route 40 134 29-3 27.67 4 101-0 120 48.569 ••"• Route 41 ..... Flow (q) from Route 42 0.000100 136 29-3 16.60 4.2600 10,-0 0.001 136 29-3 2 (See Notes) 1409h/2 120 48.570 mecT(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000668 0.217 135 28-9 7.72 2.1570 190-0 0.127 48.914 Total(Pt) Route 41 215 29'-3 285.52 4 9-3 120 48.567 "•• Route 42..... Flow (q) from Route 7 0.000258 134 29-3 27.67 4.2600 9-3 0.002 48.569 Total(Pt) Route 42 122 29-3 2 (See Notes) 143-2 120 49.331 ••"• Route 43 ..... P0(12 -3%) 21(12-3%), P0(12-3%) 49-2% 0.001541 0.217 121 28-9 12.13 2.1570 192-5 0.296 49.844 Total(Pt) Route 43 126 29'-3 2 (See Notes) 159-9 120 49.069 •••• Route 44..... P0(12-3%) 31(12-3%), 3fE(4-3%), P0(12 -3%) 0.001153 0.217 125 28'-9 10.37 2.1570 234'-2% 0.270 49.556 Total(Pt) Route 44 108 29-3 2 (See Notes) 138-1 120 49.832 Route 45 ..... P0(12-3%) 2T(12-3%), P0(12-3%) 49-2% 0.005274 0.217 107 28-9 23.58 2.1570 187-3% 0.988 51.037 Total(Pt) Route 45 104 29-3 28.21 4 (See Notes) 101-0 120 49.864 f Route 46 ..... Flow (q) from Route 7 P0(26-4) 26-4 0.000331 j 102 29-3 31.67 4.2600 36 -4 0.012 0 M.E.P.CAD, Inc. III AutoSPRlNI< 2018 04.4.5.0 t6 - COOLER / LAB AREA 10/8/2021 11:07:11AM Page 26 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pfl and shown as naj.tiva In Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 102 29-3 2 (See Notes) 138'l 120 49.876 2T(12-3%), P0(12-3%) 36-11 0.009098 0.217 101 28-9 31.67 2.1570 175-0 1.592 51.685 Total(Pt) Route 46 132 29-3 2 (See Notes) 1416h/2 120 48.581 Route 47 ..... P0(12-31/2) 2T(12-3%), P0(12-3%) 4921/2 0.001882 0.217 131 28-9 13.51 2.1570 190-9 0.359 49.157 Total(Pt) Route 47 142 29'-3 2 (See Notes) 140-1 120 48.571 ••••• Route 48 ..... mecl(12'-3%) 21(12-3%), P0(12-3%) 49-2% 0.000020 0.217 141 28-9 1.17 2.1570 189-4 0.004 48.792 Total(Pt) Route 48 118 29-3 2 (See Notes) 142'9 120 49.538 Route 49 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.002069 0.217 117 28-9 14.22 2.1570 191-111/2 0.397 50.152 Total(Pt) Route 49 120 29-3 2 (See Notes) 143-6 120 49.440 " Route 5O"" P0(12-3%) 21(12-31/2), P0(12-3%) 49-2% 0.001755 0.217 119 28'-9 13.01 2.1570 192-9 0.338 49.995 Total(Pt) Route 50 114 29-3 2 (See Notes) 140-11 1 120 49.695 Route 51 ..... P0(12-3%) 21(12-3%), P0(12-3%) 49'-2% 0.003005 0.217 113 28-9 17.40 2.1570 190-2 0.571 50.483 Total(Pt) Route 51 128 29-3 2 (See Notes) 142-2 J 120 48.920 ."• Route 52 ..... P0(12-3%) 21(12-3%), P0(12-3%) 49'-2% 0.001470 0.217 127 28-9 11.82 2.1570 191'-41/2 0.281 49.418 Total(Pt) Route 52 124 29-3 2 (See Notes) 919% T 120 49.206 Route 53 ..... P0(12-3 %) 1(12-3%) 24-7% t 0.000894 -1.387 300 32-5% 9.04 2.1570 116-5 0.104 f, © M.E.P.CAD, Inc. III AutoSPRINK 2018 v1 4.4.5.0 t6 - COOLER / LAB ARE/ 10/8/2021 11:07:11AM Page 27 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) ___________ Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 300 32-5% 5.82 2 (See Notes) 51'l 120 47.923 Flow (q) from Route 64 T(12'-31/2), P0(12-3%) 24-7% 0.002244 1.604 123 28-9 14.86 2.1570 75-8 0.170 49.697 Total(Pt) Route 53 134 29-3 27.67 2 (See Notes) 141-1 120 48.569 Route 54•"•• mecT(12'-31/2), Flow (q) from Route 42 21(12-3%), P0(12-3%) 4921/2 0.001301 % 0.217 ______________ 133 28-9 11.07 2.1570 190-3 0.248 49.034 Total(Pt) Route 54 112 29-3 2 (See Notes) 13981/2 120 49.754 Route 55 ..... P0(12-3%) 2T(12-3%), P0(12-3%) 4921/2 0.003644 0.217 111 28-9 19.31 2.1570 188-11% 0.689 50.659 Total(Pt) Route 55 148 29-3 230 2 (See Notes) I 140'll 120 48.571 Route 56 ..... P0(12-3%), Flow (q) from Route 38 2T(12-3%), P0(12-3%) 49-2% 0.000019 0.217 ______________ 147 28-9 1.13 2.1570 190-1% 0.004 48.792 Total(Pt) Route 56 138 29-3 2 (See Notes) 140-6 120 48.571 ••••• Route 57 ..... mecT(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.000051 0.217 137 28-9 1.92 2.1570 189-8% 0.010 48.797 Total(Pt) Route 57 110 29-3 2 (See Notes) 138-6 120 49.799 Route 58 ..... P0(12-3%) 2P0(12-3%), T(12'-3%) 9'-2% 0.004406 0.217 109 28-9 21.40 2.1570 187-9 0.827 50.843 Total(Pt) Route 58 116 29-3 2 (See Notes) 141-10 120 49.623 Route 59 ..... P0(12-3%) 2T(12'-31/2), P0(12-3%) 49'-2% 0.002484 0.217 115 28-9 15.70 2.1570 191-1 0.475 50.314 Total(Pt) Route 59 130 29-3 2 (See Notes) J 141-9% 120 48.758 Route 60 ..... P0(12-3%) 2T(12'-3%), P0(12-3%) 49-2% 0.001626 0.217 129 28-9 12.48 2.1570 191-0 0.311 49.285 Total(Pt) Route 60 (, © M.E,P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 t6 - COOLER! LAB AREA 10/8/2021 11:07:11AM Page 28 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit (psi) when applicable, are added Total _________________ (Foot) (Q) (Foot) (Foot) Friction(Pf) directly to (P0 and shown as 146 29-3 2 (See 140-5% 120 48.571 Route 61 ..... mecT(12'-3%) 49-2% 0.217 Notes) 145 28-9 1.14 2.1570 0.000019 2T(12'-3%), P0(12-3%) 189-8 0.004 48.792 Total(Pt) Route 61 106 29-3 2 (See 138-1 T 120 49.853 ••••• Route 62•"•• P0(12-31/2) 4921/2 t 0.217 Notes) 105 28-9 25.85 2.1570 0.006250 2T(12'-3%), P0(12-3%) 187-31/2 1.171 51.240 Total(Pt) Route 62 209 13-111/2 28.86 3 1-0 120 31.876 Route 63 ..... Flow (q) from Route 12 -0.000 210 13-11% 49.37 3.2600 0.002768 1-0 0.003 31.879 Total(Pt) Route 63 301 29-3 2 (See 95-101/2 120 49.257 "" Route 64 ..... mecT(12'-3%) 37-6% I -1.387 Notes) 300 32-5% 5.82 2.1570 0.000397 2fT(10'-51/2), fE(4'-3%) 133-5 0.053 47.923 Total(Pt) Route 64 205 13-111/2 39.16 11/2 (See 85-6 120 38.146 Route 65 ..... Flow (q) from Route 66 14-10 Notes) 204 13-11% 39.16 1.6820 0.045250 E(4'-llE(4'-11'/2),P0(9-li) 100-41/2 4.542 42.688 Total(Pt) Route 65 206 13-11% 3 (See 60'6% 1 120 37.920 Route 66 ..... fT(17'-5%) 64-6 -0.000 Notes) 205 13-11% 39.16 3.2600 0.001803 4E(6-81/2),4E(6-81/2),P0(20-2) 125-0% 0.225 38.146 Total(Pt) Route 66 4 -3-0 675.30 8 (See 2851'7 150 76.817 Route 67••••• Flow (q) from Route 1 158-3 Notes) 2 -3-0 253.02 7.7100 0.000569 4EE(11-6), E(22'-l1%), 2T(44 3009-10 1.713 -8) =530 Total(Pt) Route 67 (.,©M.E.P.CAD, Inc. IflAutoSPRINK2O18v14.4.5.O .............6- COOLER/ LABAREt, 10/8/2021 11;07:11AM ..Page29 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA Date: 10/8/2021 iEauivalent Pioe Lenoths of Valves and Fittinas (C=1 20 only) IC Value Multiplier I Actual Inside Diameter 4.87 Factor Value Of C 100 130 140 150 I \ = Schedule 40 Steel Pipe Inside Diameter J Multiplying Factor 0.713 1,16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22%° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fIg Flange FN Floatng Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. Jil AutoSPRINK 2018 04.4.5.0 t6 - COOLER! LAB AREI 10/8/2021 11:07:11AM Page 30 Job Name: Thermo Fisher - Project Gold Rush Remote Area Number: #6- COOLER / LAB AREA 150 135 120 105 90 0- 60 211 30 15 Hydraulic Graph N 1.85 0 •IIIIIIIIItIIIllIIIIII 1111111111" -J-L1 III I I I I I I I I I I I I I I I I I I I I I I I I I I I 0550 1100 1650 2200 2750 3300 3850 4400 4 Flow - gpm &@ M.E.P.CAD, Inc. jJ AutoSPRINK 2018 04.4.5.0 10/8/2021 11:06:58AM WEEFN1 RTETIDNJ , > Western Fire Protection Inc. ThermoFisher Scientific Gold Rush Tenant Improvement 5781 Van Allen Way Carlsbad, CA 92008 Automatic Wet Fire Sprinkler System 21-3573-02 Phase 2 Seismic Calculations 10-8-2021 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 Western Fire Protection Inc. 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 TOLBraceTM Seismic Bracing Calculations Contractor: Western Fire Protection Project Address: ThermoFisher - Project Gold Rush -I Address: 13630 Danielson Street Poway, CA 92064 FAXON 5781 Van Allen Way Phone: 858-513-4949 Carlsbad, California 92008 License: 588039 Job #21-3573-02 Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCO TM Brace Components Maximum Brace Length TO" (2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1 Sch.40 Fig. 1001 Clamp 1200 lbs (544 kg) 1200 lbs (544 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) 1970 lbs (894 kg) Type of Brace Sch. 10 Fig.825 Along Beam 630 lbs (286 kg) N/A Angle of Brace 450 Mm. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOTM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42 (11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCO FIG. 825 - - - - BAR JOIST SWAY BRACE ATTACHMENT Other Requirements - FM Approved Loads TOLCO FIG. 980 0 Fastener Information UNIVERSAL SWAY BRACE ATTACHMENT 021 Orientation to Connecting Surface NFPA Type H STEEL PIPE Fastener Type Rg.825 Along Beam Diameter N/A * Length N/A Maximum Load 630 lbs (286 kg) TOLCO FIG. 1001 FAST CLAMP Brace Identification on Plans BR1 Prying Factor N/A Brace Type Lateral [X] Longitudinal [ ] 4-Way Sprinkler System Load Calculation (Fpw = CpWp) Cp= 0.5034 Diameter Type Length Total Length Weight Per Unit Length Total Weight 4" (100 mm) Sch. 10 40 ft (12.2 m) 4C ft (12.2 m) 11.78 lb/ft (17.53 kg/m) 471 lbs (214 kg) Subtotal Weight 471 lbs (214 kg) Wp (incl. 15%) 542 lbs (246 kg) Main Size Type/Sch. Spacing (ft) - Sch. 10 40 Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 273 lbs (124 kg) 769 lb (348 kg) ii urace ....version oi use OT I oorace is suoject to terms ann conditions per the end user license agreement TOLBraceTM Seismic Calculations ThermoFisher - Project Gold Rush - PH 2 Job #21-3573-02 FAXON 5781 Van Allen Way ssthtgButhtess Worldwide Brace Identification BR1 Brace Type (Per NFPA#13) NFPA Type H Braced Pipe (ft) 4 Sch.10 Steel Pipe Spacing of Brace 40' 0 (12.19 m) Orientation of Brace Lateral Bracing Material 1 Sch.40 Maximum Brace Length 7'0" (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 450 Type of Fastener Fig.825 Along Beam Length of Fastener N/A Summary of Pipe within Zone of Influence 4 Sch.10 Steel Pipe (101.6 mm) 140 ft (12.2 m) G-Factor Used 0.5034 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 273 lbs (124 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 630 lbs (286 kg) Fig. 1001 Clamp 1200 lbs (544 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) Structural Member (E) BAR JOIST Calculations prepared by Grant Coito * The description of the Structural Member is for informational purposes only. T01-Brace' software calculates the brace assembly only, not the structure it is attached to. Calculated with TOLBrace" 8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations Contractor: Western Fire Protection Project Address: ThermoFisher - Project Gold Rush -I Address: 13630 Danielson Street Poway, CA 92064 FJON 5781 Van Allen Way Phone: 858-513-4949 Carlsbad, California 92008 License: 588039 Job #21-3573-02 Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTM Brace Components Maximum Brace Length 7'0" (2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1' Sch.40 Fig. 4L Clamp 730 lbs (331 kg) 730 lbs (331 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) 1970 lbs (894 kg) Type of Brace Sch. 10 Fig.825 Across Beam 1360 lbs (617 kg) N/A Angle of Brace 450 Mi *Calculation Based on CONCENTRIC Loading *please Note: These calculations are for TOLCOTM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42' (11 mm) Seismic Brace Assembly Detail LIR Value 200 TOLCO FIG. 825 Max Horizontal Load 1310 lbs (594 kg) BAR JOIST SWAY BRACE ATTACHMENT Other Requirements - FM Approved Loads TOLCO FIG. 980 fi UNIVERSAL SWAY BRACE ATTACHMENT ol STEEL PIPE Fastener Information Orientation to Connecting Surface NFPA Type E Fastener Type Fig.825 Across Beam Diameter N/A TOLCO FIG. 41- PIPE CLAMP FOR SWAY BRACING, . Length N/A Maximum Load 1360 lbs (617 kg) Brace Identification on Plans BR2 Prying Factor N/A Brace Type Lateral [] Longitudinal [X] 4-Way Sprinkler System Load Calculation (Fpw = CpWp) Cp= 0.5034 Diameter Type Length Total Length Weight Per Unit Length 1 80 Total Weight 4(100mm) Sch. 10 80 ft (24.4 rn) ft (24.4 m) 11.78 lb/ft (17.53 kg/m) 942 lbs (427 kg) Subtotal Weight 942 lbs (427 kg) Wp (incl. 15%) 1083 lbs (491 kg) Main Size Type/Sch. 4" Sch. 10 Spacing (ft) 80 I Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 545 lbs (247 kg) N/A ji UL.brace version ii) Use ot T01-Brace— is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculations ThermoFisher - Project Gold Rush - PH 2 Job #21-3573-02 FAXON 5781 Van Allen Way Powenng Business diM*Ie Brace Identification BR2 Brace Type (Per NFPA#13) NFPA Type E Braced Pipe (ft) 4 Sch.10 Steel Pipe Spacing of Brace 80'0" (24.38 m) Orientation of Brace Longitudinal Bracing Material 1 Sch.40 Maximum Brace Length 7'0" (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener Fig.825 Across Beam Length of Fastener N/A Summary of Pipe within Zone of Influence 4 Sch.10 Steel Pipe (101.6 mm) 18-0 7(2 4. 4 m) G-Factor Used 0.5034 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 546 lbs (248 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 1360 lbs (617 kg) Fig. 4L Clamp 730 lbs (331 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) Structural Member (E) BAR JOIST Calculations prepared by Grant Coito * The description of the Structural Member is for informational purposes only. T01-Brace- software calculates the brace assembly only, not the structure it is attached to. Calculated with TOLBrac&* B Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations Contractor: Western Fire Protection Project Address: Thermo Fisher - Project Gold Rush-I Address: 13630 Danielson Street Poway, CA 92064 E1TuN 5781 Van Allen Way Phone: 858-513-4949 Carlsbad, California 92008 License: 588039 Job #21-3573-02 Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTM Brace Components Maximum Brace Length 10'6" (3.2 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1" Sch.40 Fig. 1001 Clamp 1200 lbs (544 kg) 1200 lbs (544 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) 1970 lbs (894 kg) Type of Brace Sch. 10 Fig.825 Across Beam 1360 lbs (617 kg) N/A Angle of Brace 450 Min. "Calculation Based on CONCENTRIC Loading "Please Note: These calculations are for TOLCOTM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail LiR Value 300 Max Horizontal Load 582 lbs (264 kg) TOLCO FIG. 825 - BAR JOIST SWAY BRACE ATTACHMENT Other Requirements - FM Approved Loads TOLCO FIG. 980 Fastener Information UNIVERSAL SWAY BRACE ATTACHMENT oil Orientation to Connecting Surface NFPA Type E STEEL PIPE Fastener Type Fig.825 Across Beam Diameter N/A Length N/A 4 Maximum Load 1360 lbs (617 kg) TOLCO FIG. 1001 FAST CLAMP Brace Identification on Plans BR3 Prying Factor N/A Brace Type Lateral [X] Longitudinal [1 4-Way Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.5034 Diameter Type Length Total Length Weight Per Unit Length Total Weight 3(80mm) Sch. 10 40 ft (12.2 m) 40 ft (12.2 m) 7.94 lb/ft (11.82 kg/m) 318 lbs (144 kg) Subtotal Weight 318 lbs (144 kg) Wp (incl. 15%) 366 lbs (166 kg) Main Size Type/Sch. Spacing (ft) 3" Sch. 10 40 I Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 184 lbs (84 kg) 454 lb (205 kg) 1 uorace version oi use OT IULbrace,, is suoject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculations ThermoFisher - Project Gold Rush - PH 2 Job #21-3573-02 F.T*N 5781 Van Allen Way pbmfing WokM'tdo Brace Identification BR3 Brace Type (Per NFPA#13) NFPA Type E Braced Pipe (ft) 3 Sch.10 Steel Pipe Spacing of Brace 40 0 (12.19 m) Orientation of Brace Lateral Bracing Material 1 Sch.40 Maximum Brace Length 10 6 (3.2 m) Slenderness Ratio used for Load Calculation 300 True Angle of Brace for Calculation 45° Type of Fastener Fig.825 Across Beam Length of Fastener N/A Summary of Pipe within Zone of Influence 3 Sch.10 Steel Pipe (76.2 mm) 140 ft (12.2 m) G-Factor Used 0.5034 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 184 lbs (83 kg) Material Capacity 582 lbs (264 kg) Fastener Capacity 1360 lbs (617 kg) Fig. 1001 Clamp 1200 lbs (544 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) Structural Member (E) Barjoist Calculations prepared by Grant Coito * The description of the Structural Member is for informational purposes only. TOLBrace° software calculates the brace assembly only, not the Structure it is attached to. Calculated with TOLBrac&° 8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations Contractor: Western Fire Protection Project Address: Thermo Fisher -_Project Gold Rush I Address: 13630 Danielson Street Poway, CA 92064 E stT' N 5781 Van Allen Way Phone: 858-513-4949 Carlsbad, California 92008 License: 588039 Job #21-3573-02 Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTM Brace Components Maximum Brace Length TO" (2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1' Sch.40 Fig. 4L Clamp 730 lbs (331 kg) 730 lbs (331 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) 1970 lbs (894 kg) Type of Brace Sch. 10 Fig.825 Along Beam 630 lbs (286 kg) N/A Angle of Brace 450 Min. *Calculation Based on CONCENTRIC Loading *please Note: These calculations are for TOLCOTM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration O.42(11 mm) Seismic Brace Assembly Detail LIR Value 200 TOLCO FIG. 825 Max Horizontal Load 1310 lbs (594 kg) BAR JOIST SWAY BRACE ATTACHMENT Other Requirements - FM Approved Loads TOLCO FIG. 980 0 UNIVERSAL SWAY BRACE ATTACHMENT 00.1 STEEL PIPE / Fastener Information Orientation to Connecting Surface NFPA Type H , Fastener / Type Rg.825 Along Beam / Diameter N/A TOLCO FIG. 4L PIPE CLAMP FOR SWAY BRACING, Length N/A Maximum Load 630 lbs (286 kg) Brace Identification on Plans BR4 Prying Factor N/A Brace Type Lateral [ Longitudinal [X] 4-Way [1 Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.5034 Diameter Type Length Total Length Weight Per Unit Length 17.94 Total Weight 3(80mm) Sch. 10 80 ft (24.4 m) 80 ft(24.4 m) lb/ft (11.82 kg/m) 635 lbs (288 kg) Subtotal Weight 635 lbs (288 kg) Wp (incl. 15%) 730 lbs (331 kg) Main Size Type/Sch. Spacing (ft) Sch. 10 80 I Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 368 lbs (167 kg) N/A ii orace version ö} use ot I ULrace " is subject to terms and Conditions per the end user license agreement TOLBraceTM Seismic Calculations ThermoFisher - Project Gold Rush - PH 2 Job #21-3573-02 FAXON 5781 Van Allen Way Pwedng 8,siness t44irMsde Brace Identification BR4 Brace Type (Per NFPA#13) NFPA Type H Braced Pipe (ft) 3 Sch.10 Steel Pipe Spacing of Brace 80 0 (24.38 m) Orientation of Brace Longitudinal Bracing Material 1 Sch.40 Maximum Brace Length 7'0" (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener Fig.825 Along Beam Length of Fastener N/A Summary of Pipe within Zone of Influence 3 Sch.10 Steel Pipe (76.2 mm) 18-0 7(2 4. 4 m) G-Factor Used 0.5034 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 368 lbs (167 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 630 lbs (286 kg) Fig. 4L Clamp 730 lbs (331 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) Structural Member (E) Barjoist Calculations prepared by Grant Coito * The description of the Structural Member is for informational purposes only. TOLBrace" software calculates the brace assembly only, not the structure it is attached to. Calculated with TOLBrace° 8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations Contractor: Western Fire Protection Project Address: ThermoFisher - Project Gold Rush -I Address: 13630 Danielson Street Poway, CA 92064 FIIT.N 5781 Van Allen Way Phone: 858-513-4949 Carlsbad, California 92008 License: 588039 Job #21-3573-02 Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTM Brace Components Maximum Brace Length TO" (2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace V Sch.40 Fig. 1001 Clamp 1740 lbs (789 kg) 1740 lbs (789 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) 1970 lbs (894 kg) Type of Brace Sch. 10 Fig.825 Along Beam 630 lbs (286 kg) N/A Angle of Brace 450 Min. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOIM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42 (11 mm) Seismic Brace Assembly Detail LIR Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCO FIG. 825 BAR JOIST SWAY BRACE ATTACHMENT Other Requirements - FM Approved Loads TOLCO FIG. 980 Fastener Information UNIVERSAL SWAY BRACE ATTACHMENT A Orientation to Connecting Surface NFPA Type H STEEL PIPE Fastener Type Fig.825 Along Beam Diameter N/A * Length N/A / Maximum Load 630 lbs (286 kg) TOLCO FIG. 1001 / FAST CLAMP Brace Identification on Plans BR5 Prying Factor N/A Brace Type Lateral [X] Longitudinal [1 4-Way [] Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.5034 Diameter Type Length Total Length Weight Per Unit Length Total Weight 2" (50 mm) Sch. 10 40 It (12.2 m) 40 ft (12.2 m) 4.22 lb/ft (6.28 kg/m) 169 lbs (77 kg) 1.5' (40 mm) Sch. 10 27 ft (8.2 m) 27 ft (8.2 m) 3.04 lb/ft (4.52 kg/m) 82 lbs (37 kg) 1' (25 mm) Sch. 40 13 ft (4 m) 13 ft (4 rn) 2.05 lb/ft (3.05 kg/m) 27 lbs (12 kg) Subtotal Weight 278 lbs (126 kg) Wp (incl. 15%) 320 lbs (145 kg) Main Size - 2: Type/Sch. Sch. 10 Spacing (if) 40 Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable), 161 lbs (73 kg) 183 lb (83 kg) I urace version oi use 0? I OLHrace " is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculations ThermoFisher - Project Gold Rush - PH 2 Job # 21-3573-02 FAXON 5781 Van Allen Way PowedngButhess w0fldwde Brace Identification BRS Brace Type (Per NFPA#13) NFPA Type H Braced Pipe (ft) 2 Sch.10 Steel Pipe Spacing of Brace 40 0 (12.19 m) Orientation of Brace Lateral Bracing Material 1 Sch.40 Maximum Brace Length 7'0" (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener Fig.825 Along Beam Length of Fastener N/A Summary of Pipe within Zone of Influence 2 Sch.10 Steel Pipe (50.8 mm) 40 ft (12.2 m) 1.5 Sch.10 Steel Pipe (38.1 mm) 27 ft (8.2 m) 1" Sch.40 Steel Pipe (25.4 mm) 13 ft (4 m) G-Factor Used 0.5034 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 161 lbs (73 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 630 lbs (286 kg) Fig. 1001 Clamp 1740 lbs (789 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) Structural Member (E) Barjoist Calculations prepared by Grant Coito * The description of the Structural Member is for informational purposes only. TOLBracew software calculates the brace assembly only, not the structure it is attached to. Calculated with TOLBrace° 8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations Contractor: Western Fire Protection Project Address: ThermoFisher - Project Gold Rush-I Address: 13630 Danielson Street Poway, CA 92064 FAXON 5781 Van Allen Way Phone: 858-513-4949 POwWPgBUSfleSsWo(Idwtde Carlsbad, California 92008 License: 588039 Job #21-3573-02 Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCOTM Brace Components Maximum Brace Length TO" (2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1' SCh.40 Fig. 41-A Clamp 860 lbs (390 kg) 860 lbs (390 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) 1970 lbs (894 kg) Type of Brace Sch. 10 Fig.825 Across Beam 1360 lbs (617 kg) N/A Angle of Brace 450 Min. *Calculation Based on CONCENTRIC Loading *please Note: These calculations are for TOLCOIM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs (594 kg) ------------ S.1V' ,00.co no 025 Other Requirements - FM Approved Loads TC0PI00 Ul000$oLSw*v O IR400 Fastener Information Orientation to Connecting Surface NFPA Type E Fastener TOCOPA SWAY Type Fig.825 Across Beam IMOS ATTA02OMWT Diameter N/A Length N/A - Maximum Load 1360 lbs (617 kg) 024LA P0245A Brace Identification on Plans BR6 Prying Factor N/A Brace Type Lateral [ ] Longitudinal [X] 4-Way [] Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.5034 Diameter Type Length Total Length Weight Per Unit Length 14.22 Total Weight 2' (50 mm) Sch. 10 80 ft (24.4 m) 80 ft (24.4 m) lb/ft (6.28 kg/m) 338 lbs (153 kg) Subtotal Weight 338 lbs (153 kg) Wp (incl. 15%) 389 lbs (176 kg) Main Size Type/Sch. 2' Sch. 10 Spacing (ft) 80 I Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 196 lbs (89 kg) N/A I uLrace -- version ut Use at TOLurace " is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculations ThermoFisher - Project Gold Rush - PH 2 Job #21-3573-02 E'11TI1I 5781 Van Allen Way Pawving &isiness KWkwde Brace Identification BR6 Brace Type (Per NFPA#13) NFPA Type E Braced Pipe (ft) 2 Sch.10 Steel Pipe Spacing of Brace 80'0" (24.38 m) Orientation of Brace Longitudinal Bracing Material 1 Sch.40 Maximum Brace Length 7 0 (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 450 Type of Fastener Fig.825 Across Beam Length of Fastener N/A Summary of Pipe within Zone of Influence 2" Sch.10 Steel Pipe (50.8 mm) 180 ft (24.4 m) G-Factor Used 0.5034 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 195 lbs (88 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 1360 lbs (617 kg) Fig. 4LA Clamp 860 lbs (390 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) Structural Member (E) Barjoist Calculations prepared by Grant Coito * The description of the Structural Member is for informational purposes only. T01-8race°' software calculates the brace assembly only, not the structure it is attached to. Calculated with T0LBrace"° 8 Visit us at www.tolco.com Western Fire Protection Inc. ThermoFisher Scientific Project Gold Rush TI 5781 Van Allen Way Carlsbad, CA 92008 Automatic Wet Fire Sprinkler System 21-3573-02 Phase 2 Product Submittal 10-8-2021 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 9 Fax: (858) 513-1322 SECTION DESCRIPTION CONTENTS SPRINKLERS GLOBE GL-QR SEMI-RECESSED PENDENT GL5601 VIKING ELO VK530 SR UPRIGHT GLOBE GL-QR UPRIGHT GL8118 VICTAULIC V3605 DRY PENDENT SR VICTAULIC V3606 DRY PENDENT QR VICTAULIC VICFLEX SERIES AH2-CC BRAIDED FLEXIBLE HOSE 2. PIPE & FITTINGS BULL MOOSE SCH 10 & SCH 40 BLACK STEEL PIPE WHEATLAND SCH 10 & SCH 40 BLACK STEEL PIPE VICTAULIC FIRELOCK FITTINGS VICTAULIC FIRELOCK RIGID COUPLING #009N VICTAULIC FIRELOCK RIGID COUPLING #005H VICTAULIC FIRELOCK FLEXIBLE COUPLING #75 VICTAULIC No. 50 CONCENTRIC GROOVED REDUCER VICTAULIC STYLE 920 MECHANICAL-T BOLTED BRANCH OUTLET VICTAULIC STYLE 922 MECHANICAL-T BOLTED BRANCH OUTLET MERIT WELDED OUTLET FITTINGS SMITH COOPER DUCTILE IRON THREADED FITTINGS VICTAULIC FIRELOCK IGS FOR 1" PIPE 3. VALVES WATTS SERIES 709 DCDA BACKFLOW ASSEMBLY VICTAULIC SERIES 769N NXT PREACTION VALVE VICTAULIC SERIES 7C7 AIR MAINTENANCE/COMPRESSOR VICTAULIC SERIES 705 BUTTERFLY VALVE 4. HANGERS &EQB TOLCO FIG 200 ADJUSTABLE BAND HANGER TOLCO FIG 25 SURGE RESTRAINER TOLCO FIG 100 ALL THREAD ROD TOLCO FIG 980 SWIVEL SWAY BRACE ATTACHMENT TOLCO FIG 4L IN-LINE SWAY BRACE ATTACHMENT TOLCO FIG 1001 SWAY BRACE ATTACHMENT TOLCO FIG 825 BAR JOIST SWAY BRACE ATTACHMENT ERICO CADDY BRANCH LINE RESTRAINT TOLCO FIG 58 THREADED SIDE BEAM BRACKET DeWALT SUSPENDER DUAL-DIRECTIONAL 5. MISCELLANEOUS ARGCO FIRE SPRINKLER SPARE HEADBOX ARGCO FIRE SPRINKLER IDENTIFICATION SIGNS MATERIALS MAY BE SUBSTITUTED WITH LISTED EQUAL DUE TO PRODUCT AVAILABILITY* \\r RECESSED PENDENT PENDENT RECESSED PENDENT SEISMIC IBClASCE/SEI CODES 4077 Airpark Dr. Standish, Ml 48658 • 989-846-4583 www.globesprinkler.com Technical Support . 989-414-2600 techservice@globesprinkler.com SERIES GL-QR STANDARD COVERAGE, QUICK RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLERS K-FACTOR: 2.8, 4.2, 5.6, 8.0 Semi recessed pendant GENERAL DESCRIPTION at all other ceiling areas Globe Series GL-QR sprinklers are Listed Quick Response sprinklers which utilize a 3mm frangible glass bulb as the thermosensitive operating element. These sprinklers are available in upright, pendent, and recessed pendent orien- tations. They are Listed and Approved as Standard Cover- J) age sprinklers and are to be installed in accordance with the guidelines of the appropriate Installation Standard being mandated by the AHJ (i.e. NFPA 13; FM 2-0). These sprin- klers are available in various K-factors, temperatures and UPRIGHT finishes as shown. Recessed escutcheons with either 1/2 or %" vertical adjustment are available (See Approvals Ta- bles for appropriate sprinkler/escutcheon combinations and upright at Listings). Some pendent models are additionally available In-racks with a special "Seismic" escutcheon to meet the IBC-ASCE/ SEI 7 requirements for use in seismic design categories C, D & E. OPERATION Upon exposure to heat such as from a fire, the fluid in the bulb expands, compressing the air bubble within the bulb. When the air bubble can no longer compress, the fluid ex- pansion causes breakage of the glass bulb, resulting in re- lease of the water seat assembly, and discharge of water from the sprinkler. TECHNICAL DATA SIN Upright: GL2815, GL4215, GL5615, GL8115, GL8118 Pendent, Recessed Pendent: GL2801, GL4201, GL5601, GL8I0I, GL8106 Approvals cULus. FM • LPCB • CE See Approval Tables Maximum Working Pressure 175 psi (l2bar) Factory tested to 500 psi (34 bar) Minimum Operating Pressure 7 psi (48 kPa) Temperature Rating See Approval Tables Materials of Construction Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm Escutcheon Assembly - carbon steel FINISHES AND ACCESSORIES Finishes Factory Bronze • Chrome • White Polyester Black Polyester - special order Escutcheons Brass Chrome . White Polyester. Black Polyester Wrenches Standard • Recess • 1/2" NPT • 3/4" NPT NOTE: Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be expected when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmo- spheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, humidity, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTE: Users should refer to Globe's web site (www.globesprinkler. corn) to ensure that the most recent technical literature is being utilized. SEP 2019 GFS-100 PAGE 1 OF 6 INSTALLATION NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak- age. It is recommended not to exceed 14 ft.-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads; 20 ft. -lb. (26.8 Nm) to 3/4 inch NPT threads. Stepi. Sprinklers must be properly oriented. Step2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprin- kler fitting. Note: Do not grasp the sprinkler by the deflector. Step3. Wrench-tighten the sprinkler using only the appropriate wrench. Wrenches are only to be applied to the sprinkler wrench flats or wrench hex as applicable. Note: Do not apply wrench to frame arms. FIGURE 1: STANDARD SPRINKLER WRENCH 1/2 NPT P/N 325390 3/4" NPT P/N 312366 FIGURE 2: RECESSED SPRINKLER WRENCH 1/2 NPT PIN 325391 3/4 NPT P/N 325401 CARE AND MAINTENANCE Prior to installation, it is important to read and follow the "Sprinkler Caution" sheet (GFS-840) included within each box of sprinklers. This sheet is available on Globe's web site (www.globesprinkler.com). Store sprinklers in a cool, dry place. Exposure to extreme heat will damage the thermal sensing element, possibly re- sulting in premature activation. Avoid direct sunlight. Replace any sprinkler that shows any corrosion, damage, or loss of liquid from the glass bulb. Do not attempt to paint or alter the sprinkler's coating in any manner after leaving the manufacturing plant. Do not attach wiring, ropes, decorations or fixtures to a sprinkler. Absence of an escutcheon, used to cover a ceiling hole, may delay sprinkler operation in a fire situation. It is the owner's responsibility for inspection, testing and maintenance of the fire sprinkler system with all components and devices in accordance with the National Fire Protection Association Pamphlet 25 as well as any other requirements as set forth by the local Authority Having Jurisdiction (AHJ). SEP 2019 GFS-100 PAGE 2 OF 6 TABLE A: UPRIGHT SPRINKLER APPROVALS SIN GL2815 GL4215111 GL56150) GL8115* I GL8118) _I ORIENTATION UPRIGHT UPRIGHT UPRIGHT UPRIGHT UPRIGHT K-FACTOR 2.8 (40 metric) 4.2 (60 metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) 1PT 1/2(15mm) 1/2" (15mm) 1/2" (15mm) 1/2' (15mm) 3/4" (20mm) -IAZARD L.H. L.H L.H./O.H. L.H./O.H. L.H./O.H. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) CULLS Listed 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 286°F(141°C) 286°F(141°C) 286°F(141°C) 286°F(141°C) 286°F(141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) FM Approved NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) LPCB 155°F (68°C) 155°F (68°C) Ref. No. 147605 NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) CE NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) * FOR RETROFIT USE ONLY (1) cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. FRAME COMPRESSION SCREW BULB 2-1/4" BULB SEAT (57.1 mm) WRENCH LAT LOBE NPT 1/2" 7/16" (11.1 mm) NOMINAL MAKE-IN FIGURE 3: SERIES GL-QR UPRIGHT SPRINKLERS GL2815, GL4215, GL5615, GL8115 COMPRESSION SCR BULB BULB SEAT- WRENCH FLA 3/4" NPT 2-7/16° F1 (62 mm) SEP 2019 1/2" (12.7 mm) NOMINAL MAKE-IN FIGURE 4: SERIES GL-QR UPRIGHT SPRINKLERS GL8118 GFS-1 00 PAGE 3 OF 6 TABLE B: PENDENT SPRINKLER APPROVALS SIN GL2801 GL4201 01 GL5601 (1) GLBIOI * GL8106 (1) ORIENTATION PENDENT PENDENT PENDENT PENDENT PENDENT K-FACTOR 2.8 (40 metric) 4.2 (60 metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) FT 1/2" (15mm) 1/2" (15mm) 1/2" (15mm) 1/2°(15mm) 3/4" (20mm) HAZARD L. H. L.H L.H./O.H. L.H./O.H. L.H./O.H. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) cULus Listed 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) FM Approved NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) LPCB 155°F (68°C) 155°F (68°C) Ref. No. 147c/05 NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) CE NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F(141°C) 286°F(141°C) FOR RETROFIT USE ONLY (I) cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. SEP 2019 7/16" (11.1 mm) NOMINAL MAKE-IN 1/2° NPT WRENCH FLAT BULB S 9O1Dl $) BULB COMPRESSION SCREW FRAME DEFLECTOR FIGURE 5: SERIES GL-QR PENDENT SPRINKLERS GL2801, GL4201, GL5601, GLBIOI 1/2° (12.7 mm) NOMINAL MAKE-IN 3/4" NPT WRENCH FLAT BULB SEAT 2-7/16" sI $ BULB COMPRESSION SCREW FRAME DEFLECTOR FIGURE 6: SERIES GL-QR PENDENT SPRINKLERS GL8106 GFS-1 00 PAGE 4 OF 6 TABLE C: RECESSED PENDENT SPRINKLER APPROVALS SIN GL2801 (2) GL4201 ((2) J GL5601 (1)(2) f GL8IOI * (1)(2) GL8106 (1)(2)(3) ORIENATION RECESSED PEND. RECESSED PEND. RECESSED PEND. RECESSED PEND. RECESSED PEND. (-FACTOR 2.8 (40 metric) 4.2 (60 metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) NPT 1/2" 1/2" 1/2" 1/2" 3/4" HAZARD L.H. L.H L.H./O.H. L.H./O.H. LI-I/OH. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) zULus L sted 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) FM Approved 135°F (57°C) 135:F (57C) Nate: %" Adjustable Recessed NA NA NA Escutcheon only 200°F (93°C) 200°F (93°C) 135°F (57°C) 135°F (57°C) LP'P 155°F (68°C) 155°F (68°C) NA NA 175°F (79°C) NA 175°F (79°C) R3f. No. 1 47c/35 200°F (93°C) 200°F (93°C) 286°F(141°C) 286°F(141°C) 135°F (57°C) 135°F (57°C) "E NA NA 155°F (68°C) NA 155°F (68°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200 °F (93°C) * FOR RETROFIT JSE JNLY fl) CULLS _ISTED CORROSION RESISTANT SPRINKLER WITH POLYESTER COATING /2) CULLS LPCB /CEAPFROVED WITH 1/2" ADJUSTABLE AND 3/4" ADJUSTABLE RECESSED ESCUTCHEON 3) FM APPROVED FCR BRASS FINISH ONLY —2 15/16" DIA. 2" DIA. MIS. HOLE IN CEILING"1 —129/32' I I REDUCER / 1/8" MIS. MAX. - 1/2" AD). 1R1 3/4" MAX. MAX. 3/4" AD). CUP ETA I I E FIGURE 7: RECESSED ESCUTCHEON TABLED: STANDARD ESCUTCHEONS 3/4" ADJUSTABLE zRICTION FIT RECESSED ESCUTCHEON FINISH 1/2" NPT 3/4" NPT Chrome 325422 325423 Brass 325424 325420 Whi-e Polyester 325426-W 325427-W Black Polyester 325426-B 325427-B Stanlsss Steel 326140 NA 1/2 ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2" NPT 3/4" NPT Chrome 332071 326040 Brass 332072 326041 White Polyester 332073-W 326042-W Black Polyester 332073-B 326042-B 37/I" (98mm)- (101mm) DIA. MI HOLE IN CEILING REDUCER 1/8" (3mn) MIS. 5/8" (16mm) MAX. - 1/2" (12mm) AD). 7/8" (22mm) MAX. - 3/4" (19mm) AD). 1" (25mm) MIN. 11/2" (30mm) MAX. - 1/2" AD). 13/4' (44mm) MAX. 3/4" AD). FIGURE 8: SEISMIC RECESSED ESCUTCHEON Meets IBC-ASCE/SEI 7 Codes for Seismic areas C, 0, & E. TABLE E: SEISMIC ESCUTCHEONS 3/4" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2" NPT 3/4" NPT Chrome 326170 326177 White 326172-W 326178-W 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2" NPT 3/4" NPT Chrome 326201 326208 White 326203-W 326210-W SEP 2019 GFS-100 PAGE 5 OF 6 TABLE F. PART NUMBER SELECTION PART NUMBER SIN + TEMPERATURE + FINISH xxxx xxx xx IHL I SIN I I I TEMPERATURE GL2815 2815 GL4215 4215 GL5615 5615 GL8115 8115 GL8118 8118 GL2801 2801 GL4201 4201 GL5601 5601 GL8101 8101 GL8106 8106 -- 135 135°F(57°C) 155 155°F(68°C) 4- 175 175°F(79°C) 200 200°F (93°C) 286 286°F(141°C) FINISH / 01 BRONZE I 02 CHROME fiI WHITE POLYESTER 04 BLACK POLYESTER upright semi-recessed pendent Note.' All combinations may not be available. Refer to Listing/Approval Tables for available listed combinations. ORDERING INFORMATION SPECIFY: SPRINKLER Quantity . SIN . Orientation • Orifice NPT . Temperature Rating Finish • Part Number (See TABLE F) ESCUTCHEON Quantity. Finish • Part Number (See TABLE D & TABLE E) WRENCH Quantity. Part Number 1/2' NPT Standard ....................325390 3/4" NPT Standard ....................312366 1/2" NPT Recess .....................325391 3/4" NPT Recess .....................325401 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Standish, MI 48658 989-846-4583 www.globesprinkIer.com Technical Support . 989-414-2600 . techserviceglobesprinkIer.com 6 SEP 2019 GFS-100 PAGE 6 OF 6 NOTE: As of May 2018 all logos have been removed from the wrench boss. WARNING: Cancer and Reproductive Harm- Zt Page 1 o 5 STANDARD RESPONSE ELO UPRIGHT_ SPRINKLER "si l:II[1u'7Iv (STO RAG E:DENSlTyIAREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1. DESCRIPTION The Viking Standard Response ELO Upright Sprinkler VK530 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements. The special Polyester, PTFE, and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are listed/approved as indicated in the Approval Charts. The extra-large orifice provides greater flows at lower pressures than standard orifice or large orifice sprinklers. This feature allows reduced pipe sizing for hydraulically calculated sprinkler systems, which require high densities of water. Viking Standard Response Extra-Large Orifice Sprinklers may eliminate the need for a fire pump or reduce the size of the pump if it is required. On existing systems, replacing large orifice sprinklers with extra-large orifice sprinklers may provide the higher densities required to allow an increase in the hazard classifica- tion of an occupancy. Viking standard response sprinklers may be ordered and/or used as open sprin- klers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions below. 2. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class 2009 Refer to Approval Chart I and Design Criteria on page 3 for cULus Listing require- ments, and refer to Approval Chart 2 and Design Criteria on page 4 for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1992. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4" NPT or 20 mm BSP Nominal K-Factor: 11.2 U.S. (161.3 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-5/16" (58.7 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 5 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Compression Screw: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated Form No. F010692 19.10.14 Rev 19.1 Replaces Form No. F_010692 Rev 18.2.P65 (Added ENT; updated FM language.) Page 2 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Extra-Large Orifice Upright Sprinkler VK530 by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, Wax Coated = C, ENT = JN Temperature Suffix (°F/°C): 155°/68° = B, 175°I79° = D, 2000/930 = E, 286°I141° = G, OPEN = Z (PTFE only). For example, sprinkler VK530 with a Brass finish and a 155 °F168 °C temperature rating = Part No. 09679AB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 05118CW/B (available since 1981). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Standard Response Extra-Large Orifice Upright Sprinkler VK530 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_010692 19.10.14 Rev 19.1 Page 3of5 ® u,ir.iJFr'iJ 'ii II(IIs1G lII[ ECHNIAL i7If.. ELO UPRIGHT SPRINKLER VK530 (STORAGE-DENSITY/AREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color U Classification Temperature Rating' Ceiling Temperature' Ordinary 155 0F)(68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE in all temperature ratings. ENT in all temperature ratings except 135°F (57°C). Wax-Coated Brass for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax4 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant and corrosion proofing coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For PTFE coated open sprinklers only, the waterway is coated. For all ENT coated sprinklers, the waterway is coated. Wax melting point is 170 °F (76 °C) for 286 °F (141 °C) temperature rated sprinklers. 1-3/4" (45 mm) —* (20 rr Figure 2: Sprinkler VK530 Dimensions Form No. F_010692 19.10.14 Rev 19.1 Page 4 of 5 ® STANDARD RESPONSE \4& M TECHNICAL DATA ELO UPRIGHT SPRINKLER ,1 (STORAGE-DENSITY/AREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart I (UL) •Tempeture KEY Standard Response Extra-Large Orifice Upright Sprinkler VK530 Finish Al Xi-- Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals' SIN (Refer also to Design Criteria below.) Number' Style NPT BSP U.S. metric2 Inches mm cULus4 NYC 09679 VK530 Upright 3/4" -- 11.2 161.3 2-5/16 58.7 A3, B1, C2, B4 See Footnote 6. 14819 VK530 Upright -- 20 mm 11.2 1 161.3 2-5/16 58.7 A3, Bi, C2, B4 -- Approved Temperature Ratings Approved Finishes A - 286 °F (141 °C) 1 - Brass, Chrome, White Polyester', Black Polyester5, and Black PTFE5 B - 155°F (68 °C), 175°F (79 °C), 200°F 2 - Wax-Coated Brass (corrosion resistant) (93 °C), and 286 °F (141 °C) 3 - Brass with 200 °F (93 °C) Wax Coating (corrosion resistant); Maximum ambient ceiling temperature = 150 C - 155 °F (68 °C), 175 °F (79 °C), and °F (65 °C). 200 °F (93 °C) 4 - ENT' Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 MetricK-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Meets New York City requirements, effective July 1, 2008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: Standard Response Extra-Large Orifice Upright Sprinkler VK530 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard spray upright sprinklers: Designed for use in hazard occupancies up to and including Extra-Hazard Group II with a minimum operating pressure of 7 psi (0.5 bar). Sprinkler VK530 is also cULus Listed for use in High-Piled Storage Occupancies as defined in NFPA 13 with a minimum operating pressure of 7 psi (0.5 bar). The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_010692 19.10.14 Rev 19.1 Page 5 of 5 STANDARD RESPONSE ELO UPRIGHT SPRINKLER 'ii IF(II1G VK530 (STORAGE-DENSITY/AREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart 2 (FM) Temture KEY Standard Response Extra-Large Orifice Upright Sprinkler VK530 Finish Maximum 175 PSI (12 Bar) WWP Al X+- Escutcheon (if applicable) Base Part Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN le Sprinkler Style (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm 09679 VK530 Upright 3/4" -- 11.2 161.3 2-5/16 58.7 Al, A2 14819 1 VK530 I Upright -- 20 mm 11.2 161.3 2-5/16 58.7 All, A2 Approved Temperature Ratings Approved Finishes A - 155 °F (68 °C), 175 °F (79 CC), 200 °F (93 °C), and 286 °F 1- Brass and Chrome (141 C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the FM Approvals available at the time of printing. Other approvals may be in process. FM Approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Anproval Requirements: Standard Response Extra-Large Orifice Upright Sprinkler VK530 is FM Approved as a standard response upright Non-Storage sprinkler, and as a standard response upright Storage sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_010692 19.10.14 Rev 19.1 Replaces Form No. F_010692 Rev 18.2.P65 (Added ENT; updated FM language.) FireLockTM Model FL-SR/DRY Standard Coverage Standard Response Dry Upright, Pendent and Recessed Pendent Sprinklers K5.6 (8.1 SO, K8.0 -(11.5 SO \%taulicr 45.51 1.0 PRODUCT DESCRIPTION UPRIGHT STANDARD RESPONSE DRY SPRINKLERS SIN V3601 V3603 Orientation UPRIGHT UPRIGHT K-Factor1 5.61mpi8.1 SI. 8.0 Imp./11.5 S.I. Connection 1' NPT/25mm BSPT/1" IGS 1" NPT/25mm BSPT/1" IGS Max. Working Pressure 175 psi (1200 kPa) 175 psi (1200 kPa) Escutcheon Plain Plain Globe Equivalent GL5683 GL8183 PENDENT STANDARD RESPONSE DRY SPRINKLERS SIN I V3605 I V3607 Orientation PENDENT PENDENT K-Factor' 5.6 rn p.18.1 S.I. 8.0 Imp./11.5 S.I. Connection 1" NPT/25mm BSPT/1" IGS 1" NPT/25mm BSPT/1" IGS Max. Working Pressure 175 psi (1200 kPa) 175 psi (1200 kPa) Escutcheon I Plain/Flush/Sleeve and Skirt/Extended I Plain/Flush/Sleeve and Skirt/Extended Globe Equivalent I GL5680 I GL8179 RECESSED PENDENT STANDARD RESPONSE DRY SPRINKLERS SIN V3605 V3607 Orientation PENDENT PENDENT K-Factor' 5.6 Imp./8.1 S.I. 8.0 Impi11.5 S.I. Connection 1" NPT/25mm BSPT/1" IGS 1" NPT/25mm BSPT/1" IGS Max. Working Pressure 175 psi (1200 kPa) 175 psi (1200 kPa) Escutcheon Recessed Recessed Globe Equivalent I GL5680 GL8179 AVAILABLE GUARDS/SHIELDS SPRINKLER V34/V36 V34/V36 Intermediate Shield V34N36 Int. Shield/Guard Upright U Pendent U AVAILABLE WRENCHES SPRINKLER V36 Recessed V36 Open End /16 Hex-Bit (V9) Upright Pendent Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Mm. Operating Pressure: Pendent: 7 psi/48 kPa/.5 bar Upright: 12 psi/83 kPal0.8 bar Temperature Rating: See tables in section 2.0 For K-Factor when pressure is measured in bar, multiply S.I. units by 100. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com if 2.0 CERTIFICATION/LISTINGS LISIED APPROVALS/LISTINGS SIN V3601 V3603 Nominal K Factor Imperial 5.6 8.0 Nominal K Factor 5.1.2 8.1 11.5 Orientation Upright Upright Escutcheon Plain Plain Approved Temperature Ratings F°IC° 135°F157°C 135°F/57°C 155°F/68°C 155°F/68°C cULus 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 135°F/57°C FM 155°F/68°C 135°F/57°C 200°F/93°C 155°F/68°C 200°F/93°C 286°F/141°C CCC 155°F/68°C - APPROVALS/LISTINGS SIN V3605 V3607 V3605 V3607 Nominal K Factor Imperial 5.6 8.0 5.6 8.0 Nominal K Factor S.I.2 8.1 11.5 8.1 11.5 Orientation Pendent Pendent Pendent Pendent Escutcheon Plain, Flush, Sly & Skt, Ext Plain, Flush, Sly & Skt, Ext Recessed Recessed Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286'F/1 41'C 286'F/1 41'C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C FM 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C CCC 155°F/68°C - 155°F/68°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTES Listings and approval as of printing. Temperatures are listed for all hazards and approved for V3605 and V3606 dry sprinklers up to 48' length. CCCf approved for V3605 dry sprinklers 107 to 1250 mm/4.2 - 49.2 in length. 45.51 15956 Rev B Updated 03/2021 © 2021 Victaulic Company. All rights reserved. if 3.0 SPECIFICATIONS - MATERIAL Deflector: Brass or Stainless Steel Spring seal assembly Bulb nominal diameter: 5.0mm Torsion spring Split spacer: Stainless Steel Inlet fitting Load screw: Brass Pip cap: Stainless Steel Inner tube Spring seal assembly: PIFE Coated Beryllium Nickel Alloy and Stainless Steel Outer tube Frame: Brass Inlet fitting: Brass Outer tube: Galvanized Steel Pipe Inner tube: Stainless Steel Orifice insert Escutcheon plate Orifice insert: Stainless Steel Escutcheon/plate: 1010 - 1018 mild steel and stainless Frame Split spacer steel Pip cap Bulb Torsion spring: SST wire Load screw Deflector Installation wrench: Ductile Iron Material Specifications Sprinkler frame finishes: V3605, V3607 Plain brass Chrome plated White painted34 Bright White painted3 Flat black painted34 Deflector Load screw Custom painted34 Bulb pcap VC-2505 Split spacer Not available on the Intermediate Level style Pendent. Frame UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. Orifice insert NOTES Weather resistant escutcheon available upon request. For cabinets and other accessories refer to separate sheet. Outer tube Inner tube Escutcheon optional (Not provided) Torsion spring —Vj Inlet fitting Spring seal assembly Material Specifications V3601, V3603 45.51 15956 Rev B Updated 03/2021 0 2021 Victaulic Company. All rights reserved. Tee with same outlet size as sprinkler thread size. Seelmportant Installation Information" later in this NPT/BS document PT 1~'/44 mm Mm. (1½7 Hole in ceiling :JYPicai.ceiling 38 mm Mm.) I 1' IGS Fitting W! 11/4744 mm Mm. (2 Hole in ceiling 6 M 7 mm m.) Typical ceiling vktiuiIirrnm 4.0 DIMENSIONS Tee with same outlet size - - .-, , as sprinkler threac size. I I J I' See"lmportant Installation Information" later in this document - 1' NPT/BSPT A (2/ - 51 mm Mm.) 1W! 47 mm Plain Barrel, Threaded V3605, V3607 IGS Fitting I- 79 Mm.) 47mm Plain Barrel, Grooved V3605,V3607 For wet system installation or dry/preaction systems installed in areas above 40'F/5'C 4/102mm I IJ '- Finished surface 2½'/63 mm I k-31/4782 mm- Sleeve and Skirt, Threaded V3605, V3607 4/102mm 1lJL Finished surface 2½'/63 mm 14- 31/4782 mm-,I Sleeve and Skirt, Grooved V3605, V3607 For wet system installation or dry/preaction systems installed in areas above 40'F/5"C Standard offering includes made-on escutcheon with 'A" dimension shown above. Use the Adjustments for Optional Interchangeable Escutcheons" table when making optional field adjustments to the standard ordered escutcheon. Adjustments for Optional Interchangeable Escutcheons Escutcheon 'A' Dimension Adjustment Plain Barrel A=A Flush A=-¼'/6mm Recessed A = +1/4"/6mm Slv/Skrt A = -1 3/s'/35mm 45.51 15956 Rev 8 Updated 03/2021 0 2021 Victaulic company. All rights reserved. (1½'! 38 mm Mm) 5'i 33/4' 21/a"/60 mm Mm. Hole in ceiling ing surface 4.0 DIMENSIONS (CONTINUED) Tee with same outlet size as sprinkler thread size. Ir 1' IGS Fitting H - - V'See"lmportant Installation NP later in this document T/BSPT (2'5A6/ 3/4 75 mm Mm ½'/ 0"! 138 mm Mm. 1½"I38 44 mm Mm.) mm Mm. I Hole in ceiling Hole in ceiling WI / 6mmJ /Typ 6mm - Typical ceiling 1/4'/ ical ceiling 2"/ Finished surface 2/ 5t mm Finished surface 51 mm k-3'/75 mm- -3776 mm-a Flush, Threaded Flush, Grooved V3605, V3607 V3605, V3607 For wet system installation or dry/preaction systems installed in areas above 40'F/5"C Standard offering includes made-on escutcheon with A dimension shown above. Use the Adjustments for Optional Interchangeable Escutcheons table when making optional field adjustments to the standard ordered escutcheon. Adjustments for Optional Interchangeable Escutcheons Escutcheon "A" Dimension Adjustment Plain Barrel A=A Flush A=-¼/6mm Recessed A = +1/4"/6mm Slv/Skrt A = -1 3/8 /35mm - - ..........-., Tee with same outlet size as sprinkler thread size. See'lmportant Installation Information",later in this document N PT/BSPT 2/8'/6O mm Mm. ½'! (1 38 mm Mm I - - Hole in ceiling I i--i Typical ceiling Finished surface 57126 mm 31/4"/96 mm k-3½'/89 mm- Extended Sleeve and Skirt, Threaded V3605, V3607 1' IGS Fitting For wet system installation or dry/preaction systems installed in areas above 40"F/5"C Extended escutcheons are not available as interchangeable. 45.51 15956 Rev B Updated 03/2021 0 2021 Victaulic Company. All rights reserved. 5ii1tI1Iif' ,nm 4.0 DIMENSIONS (CONTINUED) Tee with same outlet size as sprinkler thread size. See "Important Installation Information", later n this document FV1 PT/BSPT (2/ 51 mm Mm.) W. ç6mm 2/ 51 mm 3/76 mm Intermediate, Threaded V3605,V3607 Tee with same outlet size as sprinkler thread size. K"s1ee'lmportant Installation Information" later in this document N PT/BS PT AF~ q___ 2/51 mm Mm. (21/47 1 1 Hole in ceiling 57 mm Mm.) I / ceiling t7/8"/47 mm 1J4.-)J '-Finished surface 11/8728 mm I Recessed, Threaded V3605,V3607 ! (21 ii t' IGS Fitting 74 mm Mm.) 1T ¼7 6mm 27 51 m 1+- 3/76 mm— Intermediate, Grooved V3605,V3607 For wet system installation or dry/preaction systems installed in areas above 40'F/5"C S36-3 BO-5409_LIT-O 1 IGS Fitting (37Ao'/ - - 87 mm Mm.) 1 I 2751 mmMin. I Hole in ceiling 1W/47 mm ~2 Finished surface mJ-27/8773 m Recessed, Grooved V3605,V3607 For wet system installation or dry/preaction systems installed in areas above 40'F/5"C Standard offering includes made-on escutcheon with A dimension shown above. Use the Adjustments for Optional Interchangeable Escutcheons table when making optional field adjustments to the standard ordered escutcheon. Adjustments for Optional Interchangeable Escutcheons Escutcheon A" Dimension Adjustment Plain Barrel A=A Flush A=-¼/6mm Recessed A=+¼'/6mm Slv/Skrt A = -1 3/a /35mm 45.51 15956 Rev B updated 03/2021 0 2021 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS (CONTINUED) 1W/47mm 47 mm 1½'/38mmMin. 1½'/38mmMin. - - - Hole in ceiling -- g (2/51 mm Mm.) caceilin9 1 ceil J , ~ ining f \-Finished surface (3/8'/80 mm Mm.) - Finished surface N PT/BS PT Tee with same outlet size I .'I as sprinkler thread size. See'lmportant Installation - - Information" later in this lGS Fitting Installed Dimensions, Threaded document Installed Dimensions, Grooved V3601, V3603 V3601, V3603 For wet system installation or dry/preaction systems installed in areas above 40'F/5"C Standard offering includes made-on escutcheon with A dimension shown above. Use the Adjustments for Optional Interchangeable Escutcheons table when making optional field adjustments to the standard ordered escutcheon. Adjustments for Interchangeable Escutcheons Escutcheon "A" Dimension Adjustment Plain Barrel A=A Flush A=-¼'/6mm Recessed A = +1/4 I6mm Slv/Skrt A=-1 3/a'/35mm 45.51 15956 Rev B updated 03/2021 0 2021 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from -670F/-550C to those shown in the table below. 1-40: Victaulic FireLockTM Automatic Sprinklers Installation and Maintenance Instructions 149: Style V9 Victaulic FireLocknM IGSTM lnstalIationReadyTM Sprinkler coupling Installation Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price Lint or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 45.51 15956 Rev B Updated 03/2021 0 2021 Victaulic Company. All rights reserved. FireLockTM Series FL-QRIDRY Standard Coverage, Quick Response Dry, Upright, Pendent and Ltuiicr Recessed Pendent Sprinklers K5.6 (8.1), K8.0 (11.5) 45.01 F 1.0 PRODUCT DESCRIPTION UPRIGHT QUICK RESPONSE DRY SPRINKLERS SIN V3602 V3604 ORIENTATION UPRIGHT UPRIGHT K-FACTOR' 5.61mp./8.1 S.I. 8.0 Imp/u.5 S.I. CONNECTION 1 NPT/25mm BSPT/1 IGS 1 NPT/25mm BSPT/1 IGS MAX WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) ESCUTCHEON Plain Plain GLOBE EQUIVALENT GL5639 GL8139 PENDENT QUICK RESPONSE DRY SPRINKLERS SIN V3606 V3608 ORIENTATION PENDENT PENDENT K-FACTOR' 5.61mp./8.1 SI. 8.0 Imp./11.5 S.I. CONNECTION 1 NPT/25mm BSPT/1' IGS 1 NPT/25mm BSPT/1" IGS MAX WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) ESCUTCHEON Plain/Flush/Sleeve and Skirt/Extended) Plain/Flush/Sleeve and Skirt/Extended GLOBE EQUIVALENT GL5635 GL8135 RECESSED PENDENT QUICK RESPONSE DRY SPRINKLERS SIN V3606 V3608 ORIENTATION PENDENT PENDENT K-FACTOR' 5.61mp./8.1 S.I. 8.0 Imp/u.5 S.I. CONNECTION 1"NPT/25mmBSPT/1IGS 1NPT/25mmBSPT/1'IGS MAX WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) ESCUTCHEON Recessed Recessed GLOBE EQUIVALENT GL5635 GL8135 AVAILABLE GUARDS/SHIELDS SPRINKLER V34N36 V34/V36 Intermediate Shield V34/V36 Int. Shield/Guard Upright Pendent AVAILABLE WRENCHES Sprinkler V36 Recessed V36 Open End 3/16 Hex Bit (V9) Upright Pendent ____________________________ • ____________________________ Factory Hydrostatic Test: 100% © 500 psi/3447 kPa/34 bar Mm. Operating Pressure: Pendent: 7 psi/48 kPa/.5 bar Upright: 12 psi/83 kPa/0.8 bar Temperature Rating: See tables in section 2.0 1 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 41-f2tiI, fnm 2.0 CERTIFICATION/LISTINGS C®US USTED APPROVALS/LISTINGS SIN V3602 V3604 Nominal K Factor Imperial 5.6 8.0 Nominal K Factor S.1 .2 8.1 11.5 Orientation Upright Upright Escutcheon Plain I Plain Approved Temperature Ratings F°IC° 135°F/57°C 135°F/57°C cULus 155 °F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C FM 155°F/68°C 155°F/68°C 200°F/93°C 286'F/141'C 200°F/93°C CCC 155°F/68°C - APPROVALS/LISTINGS SIN V3606 V3608 V3606 V3608 Nominal K Factor Imperial 5.6 8.0 5.6 8.0 Nominal K Factor 5.1.2 8.1 11.5 8.1 11.5 Orientation Pendent Pendent Pendent Pendent Escutcheon Plain, Flush, Sly & Skt, Ext Plain, Flush, Sly & Skt, Ext Recessed Recessed Approved Temperature Ratings F°IC° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C c tJLus 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155'F/68'C 155'F/68'C 135°F/57°C 135°F/57°C FM ;°° 155°F/68°C 155°F/68°C 286°F/141 °C 286°F/1 41°C 200°F/93°C 200°F/93°C - CCC 155°F/68°C - 155°F/68°C - 2 For K-Factor when pressure is measured in Bar, multiply S I. units by 10. NOTES Listings and approval as of printing. rtures are I flhF roved fTV3 up to 4jjth 45.01 15896 Rev B Updated 06/2021 0 2021 Victaulic Company. All rights reserved. Orifice mo Escutcheon pla Frarr Split spao Pip Ca Sul Load scre Deflect( Material Specifications V3606, V3608 Spring seal assemb Torsion spun Inlet fittir Inner tuE Outer tuE Frame Orifice in Outer tube Inner tube Escutcheon optional (Not provided) Torsion spring Inlet fitting Spring seal assembly—' Material Specifications V3602, V3604 victaulic.com 3.0 SPECIFICATIONS - MATERIAL Deflector: Brass or Stainless Steel Bulb Nominal Diameter: 3.0mm Split Spacer: Stainless Steel Load Screw: Brass Pip Cap: Stainless Steel Spring Seal Assembly: PTFE coated Beryllium nickel alloy and stainless steel Frame: Brass Inlet Fitting: Brass Outer Tube: Galvanized steel pipe Inner Tube: Stainless Steel Orifice Insert: Stainless Steel Escutcheon/Plate: 1010 - 1018 mild steel and stainless steel Torsion Spring: SST wire Installation Wrench: Ductile iron Sprinkler Frame Finishes: Plain brass Chrome plated White painted34 Bright White painted3 Flat black painted34 Custom painted34 VC-25055 Not available on the Intermediate Level style Pendent. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. NOTES Weather resistant escutcheon available upon request. For cabinets and other accessories refer to separate sheet. 45.01 15896 Rev B Updated 06/2021 0 2021 Victaulic Company. All rights reserved. 4.0 DIMENSIONS Tee with same outlet size - - as sprinkler thread size. I I I "See'lmportant Installation lnformation later in this N document. PT/BSPT (2/ 51 mm Mm.) 47mm Plain Barrel, Threaded V3606,V3608 Tee with same outlet size — — as sprinkler thread size. See,'lmportt Installation Information',later in this "NPT/BS document. PT 11/4'/44 mm Mm. (1½! Hole in ceiling 38 mm Mm.) I I I r/'T"pical,ceiling J7 ' 1, IGS fitting (3'/a7 ,.._. 79 mm Min . ) 1W! I11flI 47 mm Plain Barrel, Grooved V3606, V3608 For wet system installation or dry/preaction systems installed in areas above 40'F/5'C 1' IGS fitting FA (2W! 1~'/44mm Mm. 67 mm Mm.) 1:1 Hole in ceiling H J Typical ceiling 4/101 mm I '-Finished surface 21/2763 mm 1 3¼782 mm—' (jeeve and Skirt,Threaded) V3606, V3608 4/10 I 1 mm '-Finished surface 2½'763mm Grooved 6O,/3608 For wet system installation or dry/preaction systems installed in areas above 40'F/5'C Standard offering includes made-on escutcheon with "A' dimension shown above. Use the "Adjustments for Optional Interchangeable Escutcheons' table when making optional field adjustments to the standard ordered escutcheon. Adjustments for Optional Interchangeable Escutcheons Escutcheon A" Dimension Adjustment Plain Barrel A=A Flush A=-1/4"/6mm Recessed A=+¼"/6mm Slv/Skrt A=-1 3/a"/35mm 45.01 15896 Rev B Updated 06/2021 02021 Victaulic Company. All rights reserved. 1" IGS fitting (2T 75 mm Mm.) i½"!38 mm Mm. I J Hole in ceiling ¼"! 6mm -H r-" Typical ceiling lfi A 1' 2t/ 51 mm L Finished surface 3/76mm1 Flush, Grooved V3606, V3608 For wet system installation or dry/preaction systems installed in areas above 40'F/5'C I17, 1' IGS fitting "!(2'5A6 - - 74mmMin.) 1/47 F6 mm 2V 51 mm [3776 mm --)4 Intermediate, Grooved V3606, V3608 For wet system installation or dry/preaction systems installed in areas above 40'F/5'C victaulic.com 4.0 DIMENSIONS (CONTINUED) Tee with same outlet size as sprinkler thread size. i'See"lmportant Installation nformation' later in this document. NPT/BSPT (1~'Y mm Mm. 44 mm 1 T Hole in ceiling I '/4,7 I 6 mm I Typical ceiling 27 I 1llJ "Finished surface 51 mm I k-3'776 mm— Flush, Threaded V3606, V3608 Tee with same outlet size - - - ' as sprinkler thread size. I I "See"lmportant Installation Information", later in this document. NPT/BSPT (2"! 51 mm Mm.) I I f6 mm 2"! 51 mm 3/76 mm] Intermediate, Threaded V3606, V3608 Standard offering includes made-on escutcheon with "A" dimension shown above. Use the "Adjustments for Optional Interchangeable Escutcheons" table when making optional field adjustments to the standard ordered escutcheon. Adjustments for Interchangeable Escutcheons Escutcheon "A" Dimension Adjustment Plain Barrel A=A Flush A=-1/4"/6mm Recessed A=+¼"/6mm Slv/5krt A=-1 3/a'/35mm 45.01 15896 Rev B Updated 06/2021 0 2021 victaulic Company. All rights reserved. If victaulic.com 4.0 DIMENSIONS (CONTINUED) Tee with same outlet size 1' lOS fitting as sprinkler threud size. I - iti"See'lmportant Installation document. N r!0 Information",later in this PT/BSPT (3W! 87 mm Mm.) 1 1 Hole in ceiling (2¼'! T 2751 mm Min.I I 2/51 mm Mm. 57 mm Mm.) I 1Hole in ceiling *"i'ypical ceiling _ Ty pical ceiling w4 w 11/8"/47 mm 11/8747 mm I _W _ 1/8 /28mm Finished surface 11/8 /28 mm "-Finished surface L2773 rnmj 2W!73 mm i Recessed, Threaded Recessed, Grooved V3606, V3608 V3606, V3608 For wet system installation or dry/preaction systems installed in areas above 40'F/5'C 1/8747 mm 11/2738 mm Mm. :: Hole in ceiling (2'/51 mm Min.( 1 lrzTypical ceiling "-Finished surface 1 NPT/BSPT Tee with same outlet size as sprinkler thread size. ee"Important Installation Information' later in this Installed Dimensions, Threaded document. V3602, V3604 17/811/ 47 mm - 1½'/38mmMin. Hole in ceiling Typical ceiling A (3'/s780 mm Mm.) Finished surface '=' "-1' lOS Fitting Installed Dimensions, Grooved V3602,V3604 For wet system installation or dry/preaction systems installed in areas above 40'F/5'C Standard offering includes made-on escutcheon with "A" dimension shown above. Use the "Adjustments for Optional Interchangeable Escutcheons" table when making optional field adjustments to the standard ordered escutcheon. AdjustmentsforInterchangeableEscutcheons Escutcheon J "A" Dimension Adjustment PlainBarrel I A=A Flush J_A=-1/4"/6mm Recessed I A=+¼"/6mm Slv/Skrt A=-1 3/a"/35mm 45.01 15896 Rev B Updated 06/2021 02021 Victaulic company. All rights reserved. if A (1½! 38 mm Mm.) Tee with same outlet size - - ' as sprinkler thread size. See fl Information" later in this document. PT/BSPT lmportant Installation 2W/60 mm Mm. Hole in ceiling ceiling ished surface 1' IGS fitting A (2/6'! 67 mm Mm) 1 =:I 2W/ôOmmMin. Hole in ceiling T pical ceiling r//////,Yl Finished surface 57128mm II 334' 96 mm = 571; 33/4'/ victaulic.com 4.0 DIMENSIONS (CONTINUED) I 14— 31/2789 mm —'I k— 31/2789 mm - Extended Extended Sleeve and Skirt, Grooved Sleeve and Skirt, Threaded (f36V3608 V3606,V3608 For wet system installation or dry/preaction systems installed in areas above 40"F/5"C Standard offering includes made-on escutcheon with "A' dimension shown above. Use the 'Adjustments for Optional Interchangeable Escutcheons" table when making optional field adjustments to the standard ordered escutcheon. Adjustments for Interchangeable Escutcheons Escutcheon "A" Dimension Adjustment Plain Barrel A=A Flush A=-¼76mm Recessed A=+¼"/6mm Slv/Skrt A=-1 3/s"/35mm 45.01 15896 Rev B Updated 06/2021 © 2021 Victaulic Company. All rights reserved. if victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS 4 WARNING Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designers responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from —670F/-550C. 1-40: Victaulic FireLockTM Automatic Sprinklers Installation and Maintenance Instructions 149: style vo Victaulic FireLockTM IGSTM lnstgllationRegdvTM Sprinkler Coupling Installation Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal reccmmendatios, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 45.01 15896 Rev B Updated 06/2021 © 2021 Victaulic Company. All rights reserved, Victaulic® VicFlexTM Sprinkler Fittings j It -au I ic Series AH2 and AH2-CC Braided Flexible Hoses 10.85 1.0 PRODUCT DESCRIPTION Series AH2 (sAC) Available Sizes by Component Series AH2 1"/0N25 ID Braided Hose: 31, 36, 48, 60, 72/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75/140 mm straight reducer. Series AH2-CC 1'YDN25 ID Braided Hose: 31, 36, 48, 60, 72/790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75/140 mm straight reducer. Connections From Branchline 3/4"/20mm BSPT female thread (VdS only) 1 'A"/32mm BSPT female thread (LPCB only) 1"/25mm NPT or BSPT female Thread 1/25mm Grooved IGS (refer to Submittal 10.54 for additional IGS connections) No. 116 CPVC Adapter (1"/25mm Female CPVC Socket x 1"/25mm Grooved IGS) No. 142 Welded Outlet Style 922 Outlet-T Style 920N Mechanical-T Outlet No. 65 Grooved End of Run Fitting Hose Inlet o 1"/25mm Grooved IGS 1/25mm NPT or BSPT male thread 3%"/20mm BSPT male thread (VdS only) 1 14"/32mm BSPT male thread (LPCB only) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com if victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Sprinkler Reducer Sprinkler Connection: ½' and 3/4°/l5mm and 20mm NPT or BSPT female thread Straight Lengths: 5.75", 9", 13"/140mm, 230mm, 330mm 90° Elbows Standard Short Low Profile Short Standard Long Low Profile Long (Short elbows typically used with concealed sprinklers. Long elbows typically used with recessed pendent sprinklers) Brackets Style A132 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place Style A133 for surface mount applications, wood, metal and block walls, or ceilings Style A134 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment Style ABS for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment Style A137 for suspended and hard-lid ceilings Style A137 Adjustable for suspended and hard-lid ceilings Style AB10 for Armstrong® TechZoneTM ceilings Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 900 low profile elbows) Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 4/100mm. Style ABBA bracket for suspended, exposed, and hard-lid ceilings Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings o Strut channel and pipe clamp, not supplied by Victaulic Maximum Working Temperature 2250F/107°C 150°F/650C (No. 116 CPVC Adapter) Maximum Working Pressure 200 psi/1375 kPa (FM Approval) 175 psi/1206 kPa (cULus Listed) 1600 kPa/232 psi (VdS/LPCB Approved) 1.4 MPa (CCCf Approved) 175 psi/1206 kPa (No. 116 CPVC Adapter) Minimum Bend Radius 7/178mm (FM/CCCf Approval) 2/51 mm (cULus Listed) 3776.2 mm (VdS/LPCB Approved) 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. uirfiiIirrnm 1.0 PRODUCT DESCRIPTION (CONTINUED) Maximum Allowable Sprinkler K-Factors FM (1/2715mm reducer) K5.6/8,1 (SI.), (3%720mm reducer) K14.0/20,2 (S.l.) cULus (1/2715mm reducer) K8.0/11,5 (S.l.), (3%"/20mm reducer) K14.0/20,2 (SI.) VdS/LPCB (1/2715mm reducer) K5.6/8,1 (SI.), (3/4"/20mm reducer) K8.0/11,5 (SI.) 2.0 CERTIFICATION/LISTINGS C us R OLPCB * :E~ USTED NOTE The VicF/ex Series AH2 Hose has been tested and evaluated by Spears® for acceptable use with Spears® cvc Products and is therefore covered under the Spears® FlameGuard® Installer Protection Plan. 3.0 SPECIFICATIONS - MATERIAL Series AH2: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc-Plated Reducer (1/2"I15 mm or /4"/20 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut: Carbon Steel, Zinc-Plated Reducer (1/2"/15 mm or /4"/2O mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: Orange enamel (North America, Asia Pacific). Red enamel (Europe). Hot dipped galvanized. Gasket:1 Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type Ill Finish No. 116 Adapter Fitting: CPVC and Brass Seal: Victaulic EPDM 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. if victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose —o N-N.I'- iP 0 r _I!L Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1219 1073 1220 60 54.3 60 1525 1378 1525 72 66.3 72 1830 1683 1830 Series AH2-CC Braided Hose Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 622 757 36 29.5 34.8 915 749 884 48 41.5 46.8 1219 1054 1189 60 53.5 58.8 1525 1359 1494 72 65.5 70.8 1830 1664 1798 Item Description Flexible Hose _2_ Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple 6 Braid _7_ Collar/Weld Fitting 8 Sleeve 9 Reducer Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting 8 Sleeve 9 Reducer 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Ccmpany. All rights reserved. 5.25/ 133 mm 3.50/ 3 2.847 q mm 9 4E victaulic.com 4.0 DIMENSIONS (CONTINUED) Standard Reducer III J 5.75/140 mm straight reducer Optional Reducers IIlllllllMllllMllllIll JI1II 9.0/229 mm straight reducer liii IIllh!llhIllllll1ll Iiii 13.0/330 mm straight reducer 2.62/ 66.5 mm 5.50"! 139.7 mm 4.83/ 3.257 122.7 mm E I 82.6 mm Short 90° elbow reducer 2.62/ 66.5 mm J51 F 184.2 mm 6.57"! 166.9 mm Long 90° elbow reducer 5.007 127.0 mm NOTE The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. FM/VdS Approved only. Low Profile Short 90° elbow reducer Long 90° elbow reducer NOTE Style AB11: When low profiles elbows are with the Style AB11 bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. No. 116 CPVC Adapter EtoE NOTES E to E is 3.0/76.0 mm The No. 116 CPVC Adapter has 2 ft. (0.6 m) EQL of 1 Schedule 40 pipe. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic company. All rights reserved. ff i-nm 4.1 DIMENSIONS VicFlex Brackets Style AB2 Suspended Ceilings Hard-Lid Ceilings Item Description 1 24/610mm or 48/1219mm square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE Both sizes FM/VdS/LPCB Approved, cULus listed Style AB3 Surface Mount Applications FM/LPCB Approved Style AB4 Hard-Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610mmor48"/1219mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE Both sizes FM/VdS/LPCB Approved, cuLus listed. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victautic Company. All rights reserved. Style AB7 Adjustable Suspended Ceilings Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar 2 Patented 1-Bee2 Center Bracket 3 End Bracket (adjustable) NOTE Both sizes FM/Vd5/LPCB Approved. victaulic.com p 4.2 DIMENSIONS VicFlex Brackets Style AB5 Hard-Lid Ceilings rItem Description 1 24'7610 mm or 48'71219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE Both sizes FM/VdSILPCB Approved, cULus listed. Style AB7 Suspended Ceilings Hard-Lid Ceilings Item Description 1 24/610mm 0r48/1219mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE Both sizes FM/VdS/LPCB Approved. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. if Style AB11 Suspended ceilings Hard-Lid ceilings Item Description 1 24"/610 mm 0r48"/1219mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE FM/VdS Approved, cuLus listed. 4.3 DIMENSIONS VicFlex Brackets Style AB1O Suspended ceilings Armstrong® TechZoneTM Item Description 1 6"/152 mm Square Bar 2 Patented 1-Bee2® Center Bracket [ 3 End Bracket NOTE FM/VdS/LPCB Approved, cULus listed. Style AB12 Suspended ceilings Hard-Lid ceilings Item Description 1 Style AB1 2 Bracket Body 2 #2 square Drive Set Screw NOTE FM/VdS Approved. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic company. All rights reserved. Style ABMM Surface mount Stand-off mount Item Description 1 Style ABMM Bracket Body 2 Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed victaulic.com 4.3 DIMENSIONS (CONTINUED) VicF!ex Brackets Style ABBA Floor-above mount Cantilever mount Temporary mount in exposed ceilings Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar Cap Screw, Serated Flange, M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body Cap Screw, Serated Flange, M6 x 1 x 15.24, T25 Torx Drive Recessed NOTE FM Approved. NOTE FM Approved. 10.85 5839 Rev AK updated 03/2021 0 2021 Victaulic Company. All rights reserved. Bracket Assembly Style AB2 23/a /60.33 mm 1.7/43 mm j ILI, Typical ceiling grid See note 247610 mm or 48'71219 mm on Center V2707 3/4'I19 MM MAX. RECESS V2707 MAX. EXTENSION victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket Hose clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4' ½" ~" ½" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4' Max Recess ½' Max Recess 3/4' Max Recess ½" Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 2.0 30 7.0 - Bend Radius 50 80 175 "A Minimum Required 8.6 10.1 9.6 11.1 13.6 15.1 5.8 5,8 Installation 218 269 244 281 345 383 147 147 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. Bracket Assembly Style AB2 Typical 16/406mm C/C - V381/2'711 3 mm MAX. RECESS 2"x4' Stud Screw 2Aa/6B mm max. hole V38 MAX. EXTENSION 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket See chart A See Chart t 1.8745 mm -I 3½'/ 89 mm U Finished /8'716 mm ceiling Typical drywall Hose Clearance Chart Straight Reducer V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4" I 20mm ½" 113mm 3/4" I 20mm 3/4" I 20mm ½" 113mm 3/4' I 20mm /4'l 20mm ½" 113mm 3/4" I 20mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 . 193 155 183 218 180 285 320 282 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 /4'I 20mm WI 20mm ½" 1 13m Max Recess Sidewall Max Recess inches inches inches mm mm mm "R" Minimum - Bend Radius "A" Minimum Required 3.3 3.6 3.3 Installation 84 91 84 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket See chart A See Chart Bracket assembly Style AB4 _____________ 4.1/ Typical Hat I I 104mm Channel I I #10 Screw - grid I %723 mm Al Finished ceiling /8/16 mm Typical 16/406mm C _________ Typical drywall V27 /4"/19 mm MAX. RECESS 21/a"/60 mm max. hole V27 MAX. EXTENSION Hose Clearance Chart Straight Reducer LongElbow ShortElbow V2707 V3802 V2707 V3802 3/4" 1/2" 3/4 1/2" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4"Max Recess ½ Max Recess 3/4' Max Recess ½" Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 2.0 2.0 3.0 3.0 7.0 7.0 —Bend Radius 50 50 80 80 175 175 - "A Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 386 203 150 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. 11 See chart 2'x4' metal stud Bracket assembly Style AB5 U victaulic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket A See chart 2.37 57 mm 3%'/ 11 92 mm Finished /8716 mm ceiling Typ. Drywall 23,t760 mm max. hole V27 MAX. EXTENSION —Typical 16/406mm C/C V27 /4'I19 mm MAX. RECESS Hose Clearance Chart Straight Reducer "72707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 /4l 20mm ½' 113mm /4l 20mm /41 20mm ½" 113mm 3/4" I 20mm /41 20mm ½" 113mm /41 20mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7_0 Bend Radius 50 80 175 "A" Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11_1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart Low-Profile Long Elbow Long Elbow Short Elbow V2707 V3802 V2709 V3802 V3802 3/4"I 20mm ½" I 13mm 3/4" I 20mm ½" 1 13m ½" 1 13m Max Recess Max Recess Sidewall Max Recess Max Recess inches inches inches inches inches mm mm mm mm mm "R" Minimum - Bend Radius "A' Minimum Required 3.5 4.9 3.6 2.9 3.3 Installation 89 124 91 74 84 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic company. All rights reserved. 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 21/8 /60 mm 2146/68 mm I r Bracket 2/51 mm 21/8760 mm 3.07 mm. hole mm. hole c.p StyleAB11 See Chart Efl1 76 mm Assembly Ij1ijjjIjJ max. hole max. hole i.7/43 mm _T1 1 Fin ished cal 6/a /15.9 mm ceiling face ceiling grid Typical ceiling tile See Note 24/610mm or V27 V38 4871219 mm on center Pendent Hose clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 V3802 3/4 120mm 1/2 113mm Max Recess" Max Recess inches inches mm mm A" Minimum Required 4.0 3.9 Installation 102 99 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. .3 Non3naI h 14/3551 victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Low Profile Short Elbow Suspended Ceiling Grid with Recessed Sprinkler and Straight 5.757140 mm Reducer Typical Ceiling iypicai ceuiny V2707 ½/12.7 mm MAX. RECESS V2707 -Y4'/19 mm MAX. RECESS Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer 3/4719 MM 3/4"I19mm 3/4Y19mm 3/4'719 MM 3/4 719mm Recessed* Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches inches mm mm I mm mm mm mm mm mm I mm mm Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 A Installation Space 101.6 139.7 142.2 182.9 149.9 190.5 195.6 236.2 381.0 421.6 Distance from Top of 05 20 1.5 1.5 15 1.5 30 30 30 30 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 Bottom-of Gate ________ ________ * Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 3.93,,, I 2.94'! 75 çnrr 100mm 2.22'! 56 mm 3.947 0.287 ) 100 mm 7mm 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. Iff victaulic.com 4.10 DIMENSIONS Clearances Style A133 and ABMM Bracket Surface Mount Application with Recessed Sprinkler 2/51 mm mm. hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm mm mm WaliThickness 2 4 6 8 10 2 4 6 8 10 A" 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 1 9 1 13 5.75 9 3 13 5.75 9 13 5.75 9 13 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6k30.2 13a 37 .2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 HoseClearance 11.6 14.8 18.8 9.6 12.8 16.8 .8 1118 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 294 376 478 243 325 427 5 275 319 402 503 268 351 452 300 402 351 300 Bend Radius 7 8 "R" 175 200 NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. if victaulic.com S 4.11 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet art art Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm Minimum 3 4 5 6 7 R Bend Radius 80 100 125 150 175 9.4 10.4 11.4 12.4 13.4 A Mm. 238 263 289 314 339 Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 1 80 100 125 150 175 7.7 8.7 9.7 10.7 11.7 A Mm. 197 222 247 273 298 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. victaulic.com 4.12 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 1 80 100 125 150 175 A Mm. 9.4 10.4 11.4 12.4 13.41 239 264 290 315 341 Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 1 80 100 125 150 175 A Mm. 8.1 9.1 10.1 11.1 12.1 205 231 256 281 307 10.85 5839 Rev AK updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.757140 mm Reducers USTED Style AB2, AB4, AB5 and AB10 Brackets Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1/33.7mm Sch. 40 pipe inches inches feet mm Type DN meters Max Bends 31 . Straight 1/2 15.0 790 DN15 4.6 31 . Straight ½ 16.0 790 DN15 4.9 31 . Straight '/4 19.0 790 DN20 5.8 31 . Straight 3/4 20.0 790 DN20 6.1 36 . Straight ½ 18.0 915 DN15 5.5 36 Straight ½ 21.0 915 DN15 6.4 36 Straight ~ 21.0 915 DN20 6.4 36 Straight 3/4 23.0 915 DN20 7.0 48 . Straight ½ 21.0 1220 DN15 6.4 48 Straight ½ 32.0 8 1220 DN15 9.8 48 . Straight 3/4 26.0 1220 DN20 7.9 48 Straight 3/4 37.0 8 1220 DN20 11.3 60 Straight Y2 27.0 1525 DN15 8.2 60 . Straight ½ 46.0 10 1525 DN15 14.0 60 Straight 3/4 27.0 1525 DN20 8.2 60 Straight 3/4 46.0 10 1525 DN20 14.0 72 Straight ½ 31.0 1830 DN1S 9.4 72 Straight ½ 55.0 12 1830 DN15 16.8 72 Straight ~ 30.0 1830 DN20 9.1 72 Straight 3/4 60.0 12 1830 DN20 18.3 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hose with 900 Low Profile Elbows iisio Style AB11 VicFlex Bracket Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1/33.7mm Sch. 40 pipe inches inches feet mm Type DN meters Max Bends 31 LP Elbow ½ 18.0 3 790 DN15 5.5 31 LP Elbow ½ 24.0 4 790 DN15 7.3 31 LP Elbow 3/4 21.0 3 790 DN20 6.4 31 LP Elbow 3/4 24.0 4 790 DN20 7.3 36 LP Elbow 1/2 19.0 3 915 DN15 5.8 36 LP Elbow ½ 26.0 5 915 DN15 7.9 36 LP Elbow ~ 23.0 3 915 DN20 7.0 36 LP Elbow 3/4 28.0 5 915 DN20 8.5 48 LP Elbow ½ 23.0 3 1220 DN15 7.0 48 LP Elbow ½ 43.0 B 1220 DN15 13.1 48 LP Elbow ~ 30.0 3 1220 DN20 9.1 48 LP Elbow 3/4 42.0 8 1220 DN20 12.8 60 LP Elbow ½ 28.0 3 1525 DN15 8.5 60 LP Elbow ½ 49.0 10 1525 DN15 14.9 60 LP Elbow '/4 31.0 3 1525 DN20 9.4 60 LP Elbow 3/4 50.0 10 1525 DN20 15.2 72 LP Elbow ½ 31.0 3 1830 DN15 9.4 72 LP Elbow ½ 65.0 12 1830 DN15 19.8 72 LP Elbow 3/4 36.0 3 1830 DN20 11.0 72 LP Elbow ~ 63.0 12 1830 DN20 19.2 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. vicfiilirnm 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2/51 mm center line bend radius Nominal Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Length Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches inches feet feet feet feet feet feet feet feet feet feet feet feet mm DN meters meters meters meters meters meters meters meters meters meters meters meters 31 1/2 11.0 13.0 15.0 16.0 790 DN15 3.4 4.0 4.6 4.9 - - - - - - - 31 3/4 12.0 14.0 19.0 20.0 790 DN20 3.7 4.3 5.8 6.1 - - - - - - - - 36 1/2 14.0 16.0 18.0 19.0 21.0 915 DN15 4.3 4.9 5.5 5.8 6.4 - - - - - 36 '/4 17.0 19.0 21.0 22.0 23.0 915 DN20 5.2 5.8 6.4 6.7 7,0 - - - - - - 48 1/2 18.0 19.0 21.0 23.0 25.0 27.0 30.0 32.0 1220 DN15 5.5 5.8 6.4 7.0 7.6 8.2 9.1 9.8 - - - 48 3/4 21.0 24.0 26.0 28.0 31.0 33.0 35.0 37.0 1220 DN20 6.4 7.3 7.9 8.5 9.4 10.1 10.7 11.3 - - - 60 1/2 21.0 24.0 27.0 30.0 32.0 35.0 37.0 40.0 43.0 46.0 1525 DN15 6.4 7.3 8.2 9.1 9.8 10.7 11.3 12.2 13.1 14.0 60 3/4 23.0 25.0 27.0 29.0 32.0 34.0 37.0 40.0 43.0 46.0 1525 DN20 7.0 7.6 8.2 8.8 9.8 10.4 11.3 12.2 13.1 14.0 - - 72 1/2 27.0 29.0 31.0 34.0 37.0 40.0 43.0 46.0 48.0 50.0 52.0 55.0 1830 DN15 8.2 8.8 9.4 10.4 11.3 12.2 13.1 14.0 14.6 15.2 15.8 16.8 72 3/4 26.0 28.0 30.0 33.0 37.0 40.0 44.0 48.0 51.0 54.0 57.0 60.0 1830 DN20 7.9 8.5 9.1 10.1 11.3 12.2 13.4 14.6 15.5 16.5 17.4 18.3 NOTES: Values for use with 5.757140 mm straight reducers. The values in this table are provided by the manufacturer for reference only. For friction loss data in accordance with the UL certification, please refer to pages 19 and 20 of this publication. How to use this Design Guide: For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. IF victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB2, A133, AB4, AB5, A137, A137 Adj., A138, A1310, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1733.7 mm at T7178 mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters ½ 13.8 15 4.2 31 5.6 Straight 790 8.1 2 ½ 15 23.5 90* Elbow 7.1 ½ 16.6 15 5.1 36 5.6 Straight 915 8.1 2 ½ 15 25.6 90' Elbow 7.8 ½ 23.4 15 7.1 48 5.6 Straight 1220 8.1 3 ½ 15 30.7 90_Elbow 9.3 ½ 30.2 15 9.2 60 5.6 Straight 1525 8.1 4 ½ 15 35.9 90* Elbow 10.9 ½ 37.0 15 11.3 72 5.6 Straight 1830 8.1 4 ½ 15 41.1 90_Elbow 12.5 3/4 16.8 20 5.1 31 8.0 Straight 790 11.5 2 3/4 20 16.8 90_Elbow 5.1 3/4 20 20 6.0 36 8.0 Straight ________________________ 915 11.5 2 '/4 20 19.7 90_Elbow 6.0 3/4 27.8 20 8.4 48 8.0 Straight 1220 11.5 3 3/4 20 26.6 90* Elbow 8.1 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. 5.1 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) FM Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicF!ex Brackets • Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1/33.7mm at 77178 mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters '/4 35.7 20 10.9 60 8.0 Straight 4 '/4 33.6 1525 11.5 20 10.2 90_Elbow '/4 43.5 20 13.2 72 8.0 Straight 4 3/4 40.6 1830 11.5 20 12.2 90_Elbow '/4 16.5 20 5.0 31 11.2 Straight 2 3/4 17.8 790 16.1 20 5.4 90_Elbow 3/4 19.5 20 59 36 11.2 Straight 2 3/4 20.7 915 16.1 20 6.3 90* Elbow 3/4 26.7 20 8.1 48 11.2 Straight 3 3/4 27.9 1220 16.1 20 8.5 90* Elbow 3/4 33.9 20 10.3 60 11.2 Straight 4 3/4 35 1525 16.1 20 10.7 90_Elbow 3/4 41.3 20 12.5 72 11.2 Straight 4 3/4 42.2 1830 16.1 20 12.8 90_Elbow 3/4 14.9 20 4.5 31 14.0 Straight 2 3/4 15.5 790 20.2 20 4.72 90_Elbow FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 300 bends and two 900 bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 2400, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) FM Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, A137 Adj., A138, AB10, AB12, ABBA and ABMM VicF!ex Brackets Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1/33.7mm at 77178 mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches riches Imperial mm feet mm S.I. type meters 3/4 19.4 20 5.9 36 14.0 Straight 915 20.2 2 3/4 20 19.6 90_Elbow 5.9 3/4 30.3 20 9.2 48 14.0 Straight 1220 20.2 3 3/4 20 29.5 90_Elbow 8.9 3/4 33.9 60 14.0 20 Straight 10.3 1525 20.2 4 3/4 20 34.1 90* Elbow 10.4 3/4 37.5 72 14.0 20 Straight 11.4 1830 20.2 4 3/4 20 38.6 90_Elbow 11.7 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 900 bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. t,i,'G. • I;.. t.tni 5.2 PERFORMANCE - FRICTION LOSS DATA Series AH2 Braided Hose with 900 Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1/33.7mm at 7/178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches Imperial inches feet mm S.I. mm meters 31 5.6 ½ 13.7 2 790 8.1 15 4.2 36 5.6 ½ 17.0 2 915 8.1 15 5.2 48 5.6 ½ 25.0 3 1220 8.1 15 7.6 60 5.6 ½ 33.0 4 1525 8.1 15 10.1 72 5.6 1/2 41.1 4 1830 8.1 15 12.5 31 8.0 3/4 13.6 2 790 11.5 20 4.14 36 8.0 '/4 16.9 2 915 11.5 20 5.2 48 8.0 3/4 27.8 3 1220 11,5, 20 8.5 60 8.0 3/4 32.6 4 1525 11.5 20 9.9 72 8.0 3/4 40.6 4 1830 11.5 20 12.4 31 11.2 3/4 13.7 2 790 16.1 20 4.2 36 11.2 3/4 17.0 2 915 16.1 20 5.2 48 11.2 3/4 24.9 3 1220 16.1 20 7.6 60 11.2 3/4 32.9 4 1525 16.1 20 10.0 72 11.2 3/4 40.9 4 1830 16.1 20 12.5 31 14.0 3/4 13.5 2 790 20.2 20 4.1 36 14.0 3/4 16.8 2 915 20.2 20 5.1 48 14.0 3/4 24.7 3 1220 20.2 20 7.5 60 14.0 3/4 32.7 4 1525 20.2 20 9.9 72 14.0 3/4 40.7 1830 20.2 20 12.4 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. victaulic.com 5.3 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Style AB2, A134, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Equivalent Length of Length of steel pipe according to Stainless Steel Outlet EN 10255 ON 25 Maximum Number Flexible Hose Size (33,7 x 3,25) of 90° Bends at mm DN meters 3/76.2mm Bend inches inches feet Radius DN15 790 ½ 5.5 31 18.0 3 DN20 3/4 DN1 5 915 ½ 6.4 36 21.0 3 DN20 3/4 DN 15 1220 ½ 8.5 48 27.9 3 DN20 3/4 DN1 5 1525 ½ 10.7 60 35.1 4 DN20 3/4 DN1 5 1830 ½ 12.8 72 42.0 4 DN20 '/4 VdS Ceiling Manufacturers List AB2, AB7, AB10 ,AB11 AB4 AB5, AB8 1.AMF Armstrong Chicago Metallic Dipling Durlum 6.Geipel Gema-Armstrong Hilti Knauf Lafarge Linder Odenwald Richter Rigips Rockfon Pagos Suckow & Fischer USG Donn No specific approval Hilti Knauf Lafarge Lindner Rigips 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com p 5.3 PERFORMANCE - FRICTION LOSS DATA OLPCB Series AH2 and AH2-CC Braided Hose Style AB2, AB3, AB4, A135, AB7, AB8, and AB10 Brackets Length of Equivalent Length Maximum Stainless of steel pipe Number of Steel according to 900 Bends at Flexible Outlet EN 10255 DN 25 3/76.2mm Hose Size (33,7 x 3,25) Bend Radius mm mm inches meters inches type feet 15 mm ½ 790 Straight 1.8 2 20mm 31 6.0 '/4 Straight 15 mm ½ 915 Straight 3.6 20mm 36 11.9 3/4 Straight 15 mm ½ 1220 Straight 4.3 3 20mm 48 14.0 3/4 Straight 15 mm ½ 1525 Straight 4.1 20mm 60 13.6 3/4 Straight 15 mm ½ 1830 Straight 5.5 3 20mm 72 18.1 3/4 Straight Series AH2 Braided Hose Style AB2, A133, AB4, AB5, AB7, A138, AB10 and AB12 Brackets Equivalent Length of Length of 1"/33.7mm Sch. 40 Pipe Flexible Hose Straight Configuration Bend Configuration mm meters meters inches feet feet 790 0.87 2.70 31 2.9 8.9 915 1.00 2.80 36 3,3 9.2 1220 2.23 4.66 48 7.3 15.3 1525 2.90 6.5 60 9.5 21.3 1830 3.31 7.16 72 10.9 23.5 cccv NOTE Friction loss data is in accordance with G85135.16 tested at a flow rate of 114 liters per minute (30 gallons per minute). 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depres- surized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain im- portant information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. WARNING It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. It is the responsibility of the owner of a building or their authorized agent to provide the sprinkler system installer with any knowledge that the water supply might be contaminated with or conducive to the development of micro- biologically influenced corrosion (MIC), including as required by NFPA 13. Failure to identify adverse water quality issues may affect the VicFlex product and void the manufacturer's warranty. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. Victaulic VicFlex Series AH2 and AH2-CC Flexible Sprinkler Fittings may be painted provided the paint is compatible with stainless steel and zinc-plated carbon steel or ductile iron. Care should be taken to ensure the sprinkler and associated escutcheon or coverplate are not painted. Victaulic VicFlex Series AH2 and AH2-CC penetrating through non-fire rated gypsum wall (drywall) will function as designed, provided the components are installed in accordance with the respective installation instructions referenced in this document. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. virtiiiIirnm 7.0 REFERENCE MATERIALS - CHARACTERISTICS VicF!ex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N lb/linearft N/linearm 31/790 2.6 5.2 23 2.6 38 0.8 36/915 5.5 25 2.8 40 09 48/1220 6.3 28 3.1 46 12 60/1525 7.0 31 3.5 51 1.5 72/1830 168 57 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N lb/linearft N/linearm 31/790 2.6 6.1 27 1.5 22 0.8 36/915 3 6.4 29 1.6 23 0.9 48/1220 4 7.2 32 1.8 26 1.2 60/1525 5 7.9 35 2.0 29 1.5 72/1830 1.8 6 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Suspension System Actual Length ft/rn Mm. Allowable Uniform Load lb/linear ft N/linear m Direct Hung Light 5,0 75.7 Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ZO REFERENCE MATERIALS - CHARACTERISTICS (CONTINUED) Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends fibend~ 2X %r~d, mum M in im Zus rau us ben bend radiu bend radius bend bend radius tm OR Minimu OR bend radius go- Minimum bend radius Mm Minimum bend radius - bend as Minimum bend radius Mini u NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicE Iex-A B 1-A B2 l-VicFlex-AB3 l-VicFlex-AB4 I-VicFlex-AB5 l-VicFlex-AB7 l-VicFlex-AB12 I-VicE lex-A B BA l-VicFlex-ABMM LRE User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to l-VICFLEX-AB1-AB2-A1310, l-VICFLEX-AB4, l-VICFLEX-AB7, or l-VICFLEX-AB8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.85 5839 Rev AK updated 03/2021 © 2021 Victaulic Company. All rights reserved. if As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. I Wiwi @D I 0.]. _ir) 1.315 1.660 1.900 2.315 2.875 2500 4.500 6.625 8.625 , LU. 1.097 1.442 1.582 2.151 2.535 1260 4.260 6.357 8.249 rMn ErntWeight _lb_ (t) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 15.940 wet'2r Filled Wegt(IJ/ft) 1.820 2.518 3.053 4.223 5.893 '.gsi 11.796 23.038 40.086 - C. 15.21 9.91 7.16 6.27 4.92 30 - 354 2.50 1.158 1.805 eces per Lift 91 61 61 31 19 19 10 1 Lirt'Neight(1W)21_lengths 2,695 2,319 2,611 2,051 2,224 1,132 2,242 1,951 2,490 _it,09ht(1W)2L_lengths 3,019 2,650 3,060 2344 2,542 1,79 2,563 2,230 2,848 Ut'21ight(lbs)2 __lengths 3,208 2,760 3,187 2,442 2,648 2,352 2,610 9 (I] jiiI':l[I] I i? #1 ii 1.315 1.650 1.900 2375 2.815 3.500 4.500 1.049 1.380 1.60 2.051 2.459 3.058 4.026 1.680 2.270 2.120 3.550 5.800 1.580 10.800 2.055 2.918 3.502 5.114 7.815 10.783 16.316 - 1.00 1.00 1.00 1.00 1.00 tOO 1.00 70 51]__44 30 30 19 19 2,470 2,431 2,513 2305 3,554 3,024 4,309 2,822 2,118 2,872 2,635 4,116 3,456 4,925 2,940 2,894 2,932 2,145 4,350 3,601 5,130 SCHEDULE 10 0 40 VI4CTPEES: UL Listed (US & Canada) and FM approved ASTM A135 and A795 Type E, Grade A Certified Complies with NFPA-13, 13R and 14 I • Indjstry-leading hydraulic characteristics CRRof1.O and greater AL 3ipe NDT weld tested EiIüiveIma kerofJPiiI1 i!M'ë 0ThIEL EDTh/SE!ItCEES: We have the most stocking locations in the industry, for best delivery and availability Plain end or roll groove Eddy Guard Ii" bacterial-resistant internal coating Custom length options Hot dipped galvanization Reddi-Pipe® red or black pipe eliminates field painting Compatible for use in wet, dry, preaction and deluge sprinkler systems The only maker with EPDs (to help earn LEED points). (] A. NFSA NFPA ~. ' "W IFM 800.325.4461 sales®BullMoaselndustries.com IirriMIerraige IiLtr® u1aItiSi[e:ej FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL® and C-UL Listed. Wheatland Tube is the only manufacturer with FM Approval on 10 NPS Schedule 10 steel fire sprinkler pipe. Approvals and Specifications Schedule 10 and Schedule 40 meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10, 1-10 NPS) ASTM A795, Type E, Grade A (Schedule 40,1-2 NPS) ASTM A53, Type E, Grade B (Schedule 40, 2-8 NPS) ASTM A53, Type F, Grade A (Schedule 40,1-4 NPS) NFPA® 13 and NFPA 14 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings Schedule 10 and Schedule 40 can be ordered in black or hot-dip galvanized to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A53 or A795. Schedule 10 and Schedule 40 receive a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Every black steel Schedule 10 and Schedule 40 pipe also receives our MIC SHIELD TM antimicrobial coating to limit corrosion from microbes on the interior of the pipe. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: 0 BLACK 0 HOT-DIP GALVANIZED 1 Council Avenue, P.O. Box 608 info@wheatIand.com Wheatland, PA 16161 wheatland.com Tube P 800.257.8182 Follow us on Twitter: A DIVISION OFZEKELMAN INDUSTRIES F 724.346.7250 (5)Wheatlandlube IIuiIeiraIIige . _ iIe 1 L® uhmiitaI Di5th1Shet Am SCHEDULE 10 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOMINAL ID NOMINALWALL WT./FT. HO FILLEDPCS./LIFT 21' 24 25' UL [in.1rmm in mm [][rnm lbs lbs LII1 lbs CRR 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 1¼ 1.660 42.2 1.442 36.6 0.109 2.77 1.807 2.514 61 2315 2645 2756 7.3 11/2 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 2 2.375 60.3 2.157 54.8 0.109 2.77 2.640 4.222 37 2051 2344 2442 4.7 21/2 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 88.9 3.260 82.8 0.120 3.05 4.336 7.949 19 1730 1977 2060 2.6 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 8 8.625 219.1 8.249 209.5 0.188 4.78 16.960 40.086 7 2493 2849 2968 1.7 10 10.750 273.0 10.374 263.5 0.188 4.78 21.230 57.803 2 892 1019 1062 - SCHEDULE 40 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINALOD NOMINAL ID NOMINAL WALL WT./FT. H20 FILLED PCS./LIFT 21' 24' 25' UL In.in mm in lbs [Thbsl { thsj lbs [lbs CRR 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.055 70 2470 2822 2940 1.000 1¼ 1.660 42.2 1.380 35.1 0.140 3.56 2.27 2.922 51 2431 2778 2894 1.000 1% 1.900 48.3 1.610 40.9 0.145 3.68 2.72 3.602 44 2513 2872 2992 1.000 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.109 24 1845 2108 2196 1.000 2½ 2.875 73.0 2.469 62.7 0.203 5.16 5.80 7.871 20 2436 2784 2900 1.000 3 3.500 88.9 3.068 77.9 0.216 5.49 7.58 10.783 13 2069 2365 2464 1.000 3'/a 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.400 10 1915 2189 2280 1.000 4 4.500 114.3 4.026 102.3 0.237 6.02 10.80 16.311 10 2268 2592 2700 1.000 5 5.563 141.3 5.047 158.2 0.258 6.55 14.63 23.262 7 2151 2458 2560 1.000 6 6.625 168.3 6.065 154.1 0.280 7.11 18.99 31.498 5 1994 2279 2374 1.000 8** 8.625 219.1 7.981 202.7 0.322 8.18 28.58 50.240 5 3001 3430 3573 1.000 Calculated using Standard UL CPR formula, UL Fire Protection Directory Category VlZ< The CR1? is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). 8 NPS Schedule 40 and 10 NPS Schedule 10 are FM Approved but not UL Listed. @ C@ APPROVED 1 Council Avenue, P.O. Box 608 info@wheatland.com WFS-072921 Wheatland, PA 16161 wheatland.com ii® tiic1 Tube P800.257.8182 Follow us on Twitter: F 724.346.7260 . (bWheatlandTube A DIVISION OF ZEKELMANINOUSTRIES Victaulic® FireLockTM Fittings X.04-c—ta—ulicr 10.03 1.0 PRODUCT DESCRIPTION Available Sizes 11/4 - 8/DN32 - DN200 Maximum Working Pressure Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Connects pipe, provides change in direction and adapts sizes or components Pipe Materials Carbon steel 2.0 CERTIFICATION/LISTINGS c®us ILPCBI USTED EN 10311 Regulation (EU) No. 305/2011 3.0 SPECIFICATIONS - MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12 Fitting Coating: O Orange enamel. O Red enamel in Europe, Middle East, Africa, and India. O Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victauliC.Com a, victaulic.com 4.0 DIMENSIONS kCtoE.1 to El No. 001 No. 003 No. 002 No. 006 No. 001 No. 003 No. 002 No. 006 900 Elbow 450 Elbow Straight Tee Cap Approximate Approximate Approximate Approximate Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg 11/4 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 11/2 1.900 - - - - - - 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DNSO 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88,9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 1 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 - - 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 1 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 - - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - - 6.94 33.6 - - 216.3 1 173 1 10.5 1 - - 176 15.2 - - 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. 'V victaulic.com p 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No. 002 Actual Elbows Straight Tee No. 001 No. 003 Nominal Outside Size Diameter 900 Elbow 45° Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 11/4 1.660 - - - - DN32 42.4 - - - 11/2 1.900 - - - - DN40 48.3 - - - 2 2.375 3.5 1.8 8.5 3.5 DNSO 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1,5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 8.515 13.0 - 33.0 13.0 216.3 4.0 - 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. IF victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLockTM No. 006 end caps containing the "EZ" marking on the :nside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64: Victaulic® FireLockTM Rigid Coupling Style 009N 10.02: Victaulic® FireLocklM Rigid Coupling Style 005H with VicPlusTM Gasket System 29.01: Victaulic® Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for waking a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance w th industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer, of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" retorts design or utility patents Victaulic Company, and/sr its affiliated entities, in the U.S. and/or other countries, or patent applications for articles and/or methods of use in the United States and/or other countries. 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Ccmparty. All rights reserved. if Victaulic® FireLockTM Installation-Ready"" Rigid Couplings A-C-ts-uhd Style 009N and Style 109 10.64 Patented Patented 1.0 PRODUCT DESCRIPTION Available Sizes Style 009N: 11/4 - 12'/DN32 - DN300 Style 109: 1 1/4 - 2 1/2 IDN32 - 73.0 mm Pipe Material Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses please contact Victaulic. Maximum Working Pressure Up to 365 psi/2517 kPa. Function Joins carbon steel pipe with grooved ends conforming to oublication 25.01. Provides a rigid pipe joint designed to restrict axial or angular movement. 2.0 CERTIFICATION/LISTINGS c®us LPCB]USM J (E C104-la/36 EN 10311 Regulation (EU) No. 305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. [System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) O Orange enamel (North America, Asia Pacific) O Red enamel (Europe) O Optional for Style 009N: Hot dipped galvanized Gasket: (specify choice) 0 Grade "E" EPDM (Type A) Vic-PIusTM Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. Not compatible for use with hot water services or steam services. NOTES Reference should always be made to publication -100, Victaulic Field Installation Handbook for gasket lubrication instructions. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to publication 05.01, Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice) O Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial) and ASTM A563M Class 9 (metric). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). O Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating.' 1 Optional bolts/nuts are available in imperial size only. Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type Ill Finish. 10.64 7072 Rev M Updated 12/2018 0 2018 Victaulic Company. All rights reserved. vitfiiilirrnm 4.0 DIMENSIONS Style 009N Two-Bolt Installation-Ready Coupling IIi Size Maximum Maximum Allow. Bolt/Nut - Dimensions Weight Actual Pre-assembled Joint Assembled Outside Working End Pipe End Approx. X V Nominal Diameter Pressure2 Load2 Separation3 Qty. Size X V Z (Each) inches inches psi lb inches inches inches inches inches inches inches lb DN mm kPa N mm - mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 31ex2 3.13 5.00 2,75 5.00 2.00 1.4 DN32 42.4 2517 3514 2.54 2 - M10x51 79 127 70 127 51 0.6 11/2 1.900 365 1035 0.10 3/8 x2 3.38 5.13 3.00 5.13 2.00 1.5 DN40 48.3 2517 4604 2.54 2 - M10x51 86 130 76 130 51 0.7 2 2.375 365 1617 0.12 318X2½ 4.00 5.63 3.50 5.63 2.00 1.9 DN50 60.3 2517 7193 3.05 2 - M1Ox63 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.12 3/8X21/2 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 2 - M10x63 114 156 102 156 51 1.0 3.000 365 2580 0.12 3/a X21/2 4.63 6.00 4.13 6.13 2.00 2.1 DN65 76.1 2517 11476 3.05 2 M10x63 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 ¼x2½ 5.13 6.75 4.63 6.75 2.00 2.3 DN80 88.9 2517 15622 3.05 2 - M10x63 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 /a x 21/2 6.00 7.88 5.63 7.50 2.13 2.9 DN100 114.3 2517 25822 4.32 2 - M10x63 152 200 143 191 54 1.3 4.250 365 5178 0.17 3/sX21/2 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 2 - M10x63 152 1.87 137 187 54 1.4 5 5.563 365 8872 0.17 2 ,'2><3 7.25 9.25 6.75 9.13 2.25 5.0 141.3 2517 39456 4.32 - M12x76 184 235 171 232 57 2.3 5.250 365 7901 0.17 ½x3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 2 - M12x76 168 229 162 229 57 2.2 5.500 365 8672 0.17 ½x3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 38529 4.32 2 M12x76 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 ½x3¼ 8.38 10.38 7.88 10.13 2.25 6.0 DN150 168.3 2517 44469 4.32 2 M12x83 213 264 200 257 57 2.7 6.250 365 11198 0.17 ½X31/4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 2 - M12x83 200 254 187 251 57 2.5 6.500 365 12112 0.17 ½x3¼ 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 2 M12x83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 5/8 X4 10.88 13.38 10.25 13.13 2.50 11.4 DN200 219.1 2517 94863 4.32 2 - M16x 101 276 340 260 333 64 5.2 8.500 365 20712 0.17 5/8 X4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 2 - M16x 101 270 337 260 257 67 5.2 10 10.750 300 27229 0.25 %x6½ 13.75 17.00 13.25 17.13 2.75 22.6 DN250 273.0 2068 121121 6.4 2 - M22 165 349 432 337 435 70 10.3 12 12.750 300 38303 0.25 7/8 X6½ 16.00 19.00 15.50 19.13 2.75 27.6 DN300 323.9 2068 170380 6.4 2 M22 165 406 483 394 486 1 70 12.5 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 009N couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. 10.64 7072 Rev M Updated 12/2018 0 2018 Victaulic Company. All rights reserved. If victaulic.com 4.1 DIMENSIONS Style 109 One-Bolt Installation-Ready Coupling Style 109 Pre-Assembled Style 109 Joint Assembled Size Maximum Maximum Pipe End - Bolt/Nut Dimensions Weight Actual Pre-assembled Joint Assembled Outside Working End Separation - - Approx. Nominal Diameter Pressure4 Load4 Allowable5 Qty. Size YL YB X Z YL YB X Z (Each) inches inches psi lb inches inches inches inches inches inches inches inches inches inches lb mm mm kPa N mm mm mm mm mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 %x2¼ 1.88 2.50 3,13 1.88 1.88 2.63 2.75 1.88 1.4 DN32 1 42.4 2517 3514 2.54 1 M10x57 48 64 79 48 48 67 70 48 0.6 11/2 1.900 365 1035 0.10 1 %x2¼ 2.00 2.63 3.25 1.88 2.00 2.75 3.00 1.88 1.5 DN40 48.3 2517 4604 2.54 M10x57 51 67 83 48 51 70 76 48 0.7 2 2.375 365 1616 0.12 3/a x2½ 2.25 2.88 3.88 2.00 2.25 3.13 3.50 2.00 1.8 DN50 60.3 2517 7193 3.05 1 M10 x63 57 73 98 51 57 79 89 51 0.8 21/2 2.875 365 2370 0.12 %x2½ 2.50 3.13 4.38 2.00 2.50 3.38 3.88 2.00 2.1 73.0 2517 10542 3.05 1 M10x63 1 54 79 111 51 64 86 98 51 0.9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 109 couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets and cannot be used with the Style 009N. or Style 109 couplings. 10.64 7072 Rev M Updated 12/2018 0 2018 Victaulic Company. All rights reserved. If victaulic.com 5.0 PERFORMANCE Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus" FM" VdS LPCB Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DIN mm bar bar bar bar bar bar 365 365 363 363 363 363 11/4 1.660 2517 2517 2503 2503 2500 2500 DN32 42.4 25 25 25 25 25 25 365 365 363 363 363 363 11/2 1.900 2517 2517 2503 2503 2500 2500 DN40 48.3 25 25 25 25 25 25 365 365 363 363 363 363 2 2.375 2517 2517 2503 2500 2500 2500 0N50 60.3 25 25 25 25 25 25 365 365 363 363 363 363 21/2 2.875 2517 2517 2503 2500 2500 2500 73.0 25 25 25 25 25 25 3657 3638 363 363 3.000 2517 N/A 25038 N/A 2500 2500 DN65 76.1 25 7 258 25 25 365 365 363 363 363 363 3 3.500 2517 2517 2503 2503 2500 2500 DN80 88.9 25 25 25 25 25 25 365 365 363 363 363 363 4 4.500 2517 2517 2503 2503 2500 2500 ON100 114.3 25 25 25 25 25 25 363 363 4.250 N/A N/A 2503 2503 N/A N/A 108.0 25 25 290 365 363 363 232 363 5.563 2000 2517 2503 2503 1600 2500 141.3 20 25 25 25 16 25 363' 5.250 N/A N/A 25038 N/A N/A N/A 133.0 25 290' 363' 232 363 DN125 5.500 2000' N/A 25038 N/A 1600 2500 139.7 20' 258 25 25 300 365 363 363 232 363 6 6.625 2068 2517 2503 2503 1600 2500 DN150 168.3 20 25 25 7 25 16 25 363' 6.250 N/A N/A 25038 N/A N/A N/A 159.0 25 29010 3638 363 6.500 200010 N/A 25038 N/A N/A 2500 165.1 20 1 258 25 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems 400 F/C and above. Please see the VictaulicInstallation Manual 1-009N for details concerning when supplemental lubrication is required. cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. cULus listed for EN 10220 4.0 mm pipe wall. 16 cULus listed for EN 10255 4.5 mm pipe wall. 11 With optional stainless steel fasteners, cULus Listed to 175p5i/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of 316 on the end face of the bolt. 12 cUL listed to 250 psi/1720 kPa /17 bar. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. , victaulic.com p 5.0 PERFORMANCE (CONTINUED) Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus" FM" VdS LPCB Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DN mm bar bar bar bar bar bar 300 365 363 363 232 363 8 8.625 2068 2517 2503 2503 1600 2500 DN200 219.1 20 25 25 25 16 25 290 363' 8.500 2000 N/A 2503' N/A N/A N/A 216.0 20 25 10 10.750 300 300 300 300 DN250 273.0 2068 2068 2068 2068 N/A N/A 20 20 20 20 30012 300 250 300 12 12.750 206812 2068 1720 2068 N/A N/A DN300 323.9 2012 25 17 20 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40 F/c and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. cULus listed for EN 10220 4.0 mm pipe wall. 10 cULus listed for EN 10255 4.5 mm pipe wall. 11 With optional stainless steel fasteners, cULus Listed to 175p5i/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of 316 on the end face of the bolt. 12 cUL listed to 250 psi/1720 kPa /17 bar. 5.1 PERFORMANCE Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals13 The information provided below is based on the latest listing and approval data at the time of publication. Listings/ Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM_______________ Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi inches inches kPa kPa kPa kPa DN mm bar bar bar bar 365 365 365 365 11/4 1.660 DN32 42.4 2517 2517 2517 2517 25 25 25 25 365 365 365 365 11/2 1.900 DN40 48.3 2517 2517 2517 2517 25 25 25 25 365 365 365 365 2 2.375 DNSO 60.3 2517 2517 2517 2517 25 1 25 25 25 365 365 365 365 2.875 21/2 73.0 2517 2517 2517 2517 25 25 25 25 13 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the Victaulic Installation Manual 1-109 for details concerning when supplemental lubrication is required. 10.64 7072 Rev M Updated 12/2018 0 2018 Victaulic Company. All rights reserved. If vifiiiIirrnm 5.2 PERFORMANCE Specialty Pipe Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals Size PressureRating cULus FM psi psi inches kPa kPa Pipe Type DIN bar bar 1¼-4 300 EF DN32— DIN 100 2068 N/A 20 300 300 EL 2068 2068 DN32—DN50 20 20 300 ET40 2068 N/A 0N32—DN50 20 300 EZF 3-4 2068 N/A 0N80—DN100 20 300 300 EZT 1 1/4-2 2068 2068 DN32—DN50 20 20 300 FF 1 1/2-4 2068 N/A N DN4O—D100 20 300 300 GL 1 1/4-2 2068 2068 DN32—DN50 20 20 300 300 2068 2068 DN32—DN100 20 20 IMF 175 175 1205 1205 DN150 12 12 300 300 MT 1 1/4-2 2068 2068 DN32—DN50 20 20 300 MLT 1 1/4-2 N/A 2068 DN32—DN50 20 300 TF 21/2-4 N/A 2068 73.0 rnm—DN100 20 175 300 WG5,WGSE,WF5,WG7,WG7E,WL7 1 1/4-4 1205 2068 DN32— DIN 100 12 20 300 300 WLS 2068 2068 DN32—DN50 20 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZF = EZ-Flow steel pipe manufactured by Northwest Pipe Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FE = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. ME = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MLT = MLT steel pipe manufactured by Wheatland Tube Co TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG5, WG5E, WF5 = WGalweld 5, WGalweld 5E, WFIow 5 steel pipe manufactured by Wuppermann Stahl GmbH. WG7, WG7E, WL7 = WGalweld 7, Wgalweld 7E, WLight 7 steel pipe manufactured by Wuppermann Stahl GmbH WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. ff victaulic.com 5.3 PERFORMANCE Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size PressureRating cULus FM inches psi psi Pipe Type DN bar bar 300 1¼-2½ DN32-73.0mm N/A 2068 EF 20 300 1½-2½ 0N40 —73.0 mm 2068 N/A 20 300 Easy-Flow 11/4 _2 N/A 2068 DN32 - DN50 20 300 EL 1¼-2 N/A 2068 DN32 - DN50 20 300 300 ET4O 1¼-2 2068 2068 DN32 - DNSO 20 20 300 1¼-2 DN32 - DN50 N/A 2068 EZT ____________________________ 20 300 1½-2 DN40 - DN50 2068 N/A 20 300 300 FF 1½_21/2 2068 2068 DN40 —73.0mm 20 20 300 GL 1¼-2 N/A 2068 DN32 - DNSO 300 300 MF 1'/4-2½ 2068 2068 DN32 —73.0 mm 20 20 300 300 MT 1¼-2 2068 2068 0N32—DNJ50 20 20 300 300 MLT 1¼-2 2068 2068 DN32 - DN50 20 20 300 TF 2½ N/A 2068 73.0 mm 20 300 WG7,WG7E 1¼-2 N/A 2068 DN32—DN50 20 300 WLS 1¼-2 N/A 2068 DN32—DN50 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. Easy-Flow = Easy-Flow steel pipe manufactured by Borusan Mannesmann Boru. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FF = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = DL steel pipe manufactured by Wheatland Tube Co. MF = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MLT = MLT steel pipe manufactured by Wheatland Tube Co. TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG7, WG7E = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev M Updated 12/2018 0 2018 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS A WARNING 1411, rII Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and tire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS 05.01: Seal Selection Guide 25.01: Original Groove System (OGS) Groove Specifications 1-009N: Installation Instructions FireLock EZ°M Rigid Coupling Style 009N 1-100: Victaulic Field Installation Handbook 1-109: Installation Instructions FireLocklM One-Bolt Rigid Coupling Style 109 l-ENDCAP: Victaulic End Caps Installation Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF formal on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.64 7072 Rev M Updated 12/2018 0 2018 Victaulic Company. All rights reserved. FireLock® Rigid Coupling Style 005H with Vic-PIusTM Gasket System Patented Exaggerated for clarity (Pllus System Approvals/Listings: c®us p [LPCBJ USTED 104-la/02 See Victaulic Publication 10.01 for more details. LPC and VdS Approved, see notes on page 3 Product Description: FireLock Style 005H rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005H FireLock coupling are designed and recommended for use ONLY on fire protection systems. Vic-Plus°' Gasket System: Victaulic offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The Vic-Plus System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. Job/Owner System No. Location Contractor Submitted By Date \jZtauIic 10.02 Material Specifications: Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Standard: Orange enamel (North America); red enamel (Europe) El Optional: Hot dipped galvanized Coupling Gasket: (specify choice) NOTE: Additional gasket styles are available, contact Victaulic for details. El Grade "E" EPDM Type A VicPlusr Gasket System' EPDM (Violet color code). FireLock products have been Listed by underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Vic-Plus" Gasket System, requiring no field lubrication for most installation conditions. 0 Grade "L" silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal® Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASIM A-183. Standard gasket and FlushSeal gasket approved for dry pipe systems to -40°E/-40°c. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. Engineer Spec Section Paragraph Approved Date victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Dimensions: Rated for wet and dry sprinkler systems at 350 psi/2413 kPa for 1 ¼ - 4/32 - 100 mm sizes and 300 psi /2068 kPa for 4 ¼ - 8/108 - 200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005H is rigid and does not accommodate expansion, contraction or angular 9 deflection. Actual Maximum Maximum Allow. Approx. Nominal Outside Working End Pipe End Dimensions ___________ Weight X V Z Size Diameter Pressure 14 Load' Separation' Bolt/Nut' Each inches inches psi lbs. inches No- size inches inches inches lbs. mm mm kPa N mm inches mm mm mm kg 1 1/4 1.660 350 755 0.05 2.75 4.50 1.88 1.2 32 1 42.4 2413 3370 1.2 2-3/8 X2¼ 1 70 114 48 0.5 11/2 1.900 350 990 0.05 3.00 4.75 1.88 1.2 40 48.3 2413 4415 1.2 2-3/sx2¼ 76 121 48 0.5 2 2.375 350 1550 0.07 3.50 5.25 1.88 1.6 50 60.3 2413 6900 1.7 2-'/sx2½ 89 133 48 0.7 21/2 2.875 350 2270 0.07 4.00 5.75 1.88 1.9 65 73.0 2413 10110 1.7 2-3/a X2½ 102 146 48 .09 76.1 mm 3.000 350 2475 0.07 2-/8 x 2½ 4.13 5.75 1.88 1.9 76.1 2413 11010 1.7 105 146 48 0.9 3 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 2-3/X21/2 118 156 48 1.0 4 4.500 350 5565 0.16 5.75 7.25 2.13 3.1 100 114.3 2413 24770 4.1 2- '/8 x 2½ 146 184 54 1.4 108.0 mm 4.250 300 4255 0.16 2- ¼ x 2½ 5.63 7.25 2.13 3.1 108.0 2068 18940 4,1 143 184 54 1.4 5 5.563 300 7290 0.16 6.88 9.00 2.13 4.5 125 141.3 2068 32445 4.1 2- 1/2 x 3 1 175 229 54 2.0 133.0 mm 5.250 300 6495 0.16 2-½x2~ 6.63 9.00 2.13 4.5 133.0 2068 28900 4.1 168 229 54 2.0 139.7 mm 5.500 300 7125 0.16 2-½X23/4 6.88 9.00 2.13 4.8 139.7 2068 31715 4.1 175 229 54 2.2 6 6.625 300 10340 0.16 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 2-½x3 203 254 53 2.3 159.0 mm 6.250 300 9200 0.16 2-½x2~ 7.63 10.00 2.13 5.5 159.0 2068 40955 4.1 194 254 54 2.5 165.1 mm 6.500 300 9955 0.16 2-½x3 8.15 10.00 2.13 5.5 165.1 2068 44295 4.1 207 254 54 2.5 8 8.625 300 17525 0.19 10.50 13.14 2.63 11.3 200 219.1 2068 78000 4.8 2-'/8X4¼ 267 334 67 5.1 1 Working Pressure and End Load are total, from all internal anc external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications, contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. 2 The allowable pipe separation dimension shown is for system layout purposes only. Style 005H couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 4 Style 005H couplings are VdS and [PC Approved to 16 Bar/2-35 psi. ...... . victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Listings/Approvals: The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure psi Related Working Pressure psi Related Working Pressure psi Pipe Sch. Size inches UL ULC FM Pipe Sch. Size inches UL ULC FM Pipe Sch. Size inches UL ULC FM 5 11/4-3 175 175 175 EL 11/4_2 300 N/A N/A MT 11/4 -2 300 N/A N/A lh/4 _3 350 350 350 El 11/4-2 300 N/A N/A STF 11/4-4 N/A N/A 300 10,40 5-8 300 300 300 EZ 4-6 300 N/A 300 Steady 11/4 _2 N/A N/A 300 BLT 11/4-2 300 300 N/A FF 11/4 -4 N/A N/A 300 IF 3-8 N/A N/A 300 DF 11/4 -4 300 300 300 GAL -7 1 11/4 -2 300 N/A N/A WLS 11/4 _2 300 300 N/A Dl 11/4 -2 300 300 N/A MLT 1¼-2 300 N/A N/A XL 1¼-3 300 300 300 EF 11/4 -4 1757 N/A 175 1 MF 1 11/4 _4 300 N/A 3001 5 FM approved for service in 11/2-4" pipe. 6 UL Listed for service up to 4 pipe Only. 7 UL Listed for service up to 3" only. Installation Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulice is a registered trademark of Victaulic Company. ff Victaulic® Flexible Coupling "sj4taUIic Style 75 06.05 1 - 87DN25 - DN200 1.0 PRODUCT DESCRIPTION Available Sizes 1 - 8'/DN25 - DN200 Pipe Material Carbon steel Stainless steel Maximum Working Pressure Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 500 psi/3447 kPa/34 bar Working pressure dependent on material, wall thickness and size of pipe Application Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories Provides a flexible pipe joint which allows for expansion, contraction and deflection Up to 50% lighter in weight than standard Victaulic Style 77 or Style 177N flexible couplings 2.0 CERTIFICATION/LISTINGS Ei ILPCBIum @' NOTES Download publication 10.01 for Fire Protection certifications/Listings Reference Guide. See publication 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) O Standard: Orange enamel O Optional: Hot dipped galvanized O Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice') O Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30°F to +230°F/-340C to +110°C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. O Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range —20°F to +180°F/-29°C to +82°C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over +140017/+600C and water over +150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER. O Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) 0 Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, finish Type Ill (imperial) or Type II (metric). O Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. 2 Optional bolts/nuts are available in imperial sizes only. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS Style 75 lei 'U a-- ___ Pipe End Deflection from Size Separation3 Centerline3 Bolt/Nut - Dimensions Weight Actual Outside Approx. Nominal Diameter Allowable Per Cplg. Pipe Qty. Size X Y Z (Each) inches inches inches inches/ft. imperial inches inches inches lb DN mm mm Degrees mm/rn - metric mm mm mm kg 1 1.315 0-0.06 0.57 3/8X2 2,38 4.27 1.77 1.3 DN25 33.7 0-1.6 - 2° 43' 48 2 - M10x51 61 108 45 0.6 1 1/4 1.660 0-0.06 2° 10' 0.45 2 ~x2 2.68 4.61 1.77 1.4 DN32 42.4 0-1.6 - 38 - M10x51 68 117 45 0.6 1½ 1.900 0-0.06 0.40 3/8X2 2.91 4.82 1.77 1.5 DN40 48.3 0-1.6 - 1° 56' 33 2 - M10x51 74 122 45 0.6 2 2.375 0-0.06 1°- 31' 0.32 2 %x2 3.43 5.22 1.88 1.7 DN50 60.3 0-1.6 26 - M10x51 87 133 48 0.8 21/2 2.875 0-0.06 1° 15' 0.26 2 3/a x2 3.88 5.68 1.88 1.9 73.0 0-1.6 - 22 - M10x 51 98 144 48 0.9 3.000 0-0.06 10 - 12' 0.26 2 3/8X2 4.00 5.90 1.88 1.9 DN65 76.1 0-1.6 22 - M10x51 102 150 48 0.9 3 3.500 0-0.06 0.22 2 ½ x 2~ 4.50 7.00 1.88 2.9 DN80 88.9 0-1.6 10 - 2' 18 - M12x70 114 178 48 1.3 31/2 4.000 0-0.06 0.19 ½x23/4 5.00 7.50 1.88 2.9 DN90 101.6 0-1.6 00-54' 16 2 M12x70 127 191 48 1.3 4 4.500 0-0.13 10 - 36' 0.34 2 ½x2~ 5.80 8.03 2.13 4.1 DN100 114.3 0-3.2 28 M12x70 147 204 54 1.9 4.250 0-0.13 0.35 ½x2 3/4 5.55 7.79 2.13 3.7 108.0 0-3.2 10 41' 29 2 M12x70 141 198 54 1.7 5.000 0-0.13 0.25 3/8X3¼ 6.13 9.43 2.13 5.5 1° 26' 2 127.0 0-3.2 - 21 - M16x83 156 240 54 2.5 5 5.563 0-0.13 0.27 %x3¼ 6.88 10.07 2.13 5,8 10 - 18' 2 141.3 0-3.2 23 - M16x83 175 256 54 2.6 5.250 0-0.13 0.28 %x3¼ 6.55 9.37 2.13 6.0 133.0 0-3.2 10 - 21' 24 2 - M16x83 166 238 54 2.7 5.500 0-0.13 1° 18' 0.28. 2 ½x3¼ 6.80 9.59 2.13 6.3 DN125 139.7 0-3.2 - 24 - M16x83 173 244 54 2.9 6.000 0-0.13 10-12' 0.21 2 5/sx3¼ 7.38 10.48 1.88 6.2 152.4 0-3.2 18 - M16x83 187 266 48 2.8 6 6.625 0-0.13 10 - 5' 0.23 2 5/ax3¼ 8.00 11.07 2.13 7.0 DN150 168.3 0-3.2 18 - M16x83 203 281 54 3.2 6.250 0-0.13 0.24 2 5/8 x3'/4 7.63 10.49 2.13 6.8 159.0 0-3.2 10 - 9 20 - M16x83 194 266 54 3.1 6.500 0-0.13 0.23 %x3¼ 7.84 10.66 2.08 6.6 165.1 0-3.2 10 - 7 58 2 - M16x83 199 271 53 3.0 8.515 0-0.13 0.18 ~x4¼ 10.19 13.75 2.32 13.2 216.3 0-3.2 - 0° 51' 46 2 - M20 x 108 259 350 59 6.0 8 8.625 0-0.13 0.18 ~x4¼ 10.34 13.97 2.13 12.4 00-50' 2 DN200 219.1 0-3.2 - 14 M20 108 263 355 59 5.6 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 34_3 ½VDN20 - DN90; 25% for 47DN100 and larger. NOTE Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. N victaulic.com 5.0 PERFORMANCE Style 75 Size Maximum Actual Outside Working Maximum Nominal Diameter Pressure4 End Load4 inches inches psi lb DN mm kPa N 1 1.315 500 680 DN25 33,7 3447 3,025 1¼ 1.660 500 1080 0N32 42.4 3447 4,805 1 ½ 1.900 500 1420 DN40 48.3 3447 6,320 2 2.375 500 2215 DN50 60.3 3447 9,860 21/2 2.875 500 3245 73.0 3447 14,440 3.000 500 3535 DN65 76.1 3447 15,730 3 3.500 500 4800 DN80 88.9 3447 21,360 31/2 4.000 500 6300 DN90 101.6 3447 28,035 4 4.500 500 7950 DN100 1143 3447 35,380 4.250 450 6380 108.0 3103 28,395 5.000 450 8820 127.0 3103 39,250 5 5.563 450 10935 141.3 3103 48,660 5.250 450 9735 133.0 3103 43,325 5.500 450 10665 0N125 139.7 3103 47,460 6.000 450 12735 152.4 3103 56,670 6 6.625 450 15525 DN150 168.3 3103 69,085 6.250 450 13800 159.0 3103 61,405 6.500 450 14930 165.1 3103 66,412 8.515 450 25625 216.3 3103 113,986 8 8.625 450 26280 DN200 219.1 3103 116,945 Working Pressure and End Load are total, from all internal and external loads, based on ANSI B36.10 sized carbon steel pipe, grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 06.05 1470 Rev P Updated 10/2017 0 2017 Victaulic Company. All rights reserved. victaulic.com p 6.0 NOTIFICATIONS WARNING Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. 7.0 REFERENCE MATERIALS 02.06: Victaulic® Potable Water Approvals ANSI/NSF 05.01: Victaulic® Seal Selection Guide - Elastomeric Seal Construction 06.15: Victaulic® Pressure Ratings and End Loads for Victaulic Couplings on Steel Pipe 10.01: Victaulic® Products for Fire Protection Pipings Systems - Regulatory Approval Reference Guide 17.01: Victaulic® Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products 17.09: Victaulic® Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe 25.01: Victaulic® Standard Groove Specifications 26.01: Victaulic® Design Data 29.01: Victaulic® Terms and Conditions of Sale 1-100: Victaulic® Field Installation Handbook User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product ipecifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer, of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in POF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to she Warranty section of the current Price List or contact Victaulic for details. under any palest or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 06.05 1470 Rev P Updated 10/2017 0 2017 Victaulic Company. All rights reserved. l4-EtoE --j 4 EtOE Lj L~ Fabricated Steel Fabricated Steel No. 50 No. 51 E to EtoE - ft1Ur No. 50 No. 51 victaulic.com 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 Concentric No. 51 Eccentric E to E EtoE - l- EtoE - EtoE - L~ E:~ L~ No. 50 No. 51 Fabricated Steel Fabricated Steel I No. 50 No. 51 No. 50 concentric No. 51 Size Reducer Eccentric Reducer Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb inches lb DN mm kg mm kg 1¼ 3% 1.9 DN32 DN20 + 0.9 - - 1 1.9 DN25 + 0.9 - - 1½ 3% 1.4 DN40 DN20 + 0.6 - - 2.50 0.8 8.50 (sw) 4.5 1 0N25 64 0.4 216 2.0 2.50 1.0 11/4 DN32 64 0.5 - 2 3/4 2.50 0.9 9.00 (sw) 2.0 DN50 DN20 64 0.3 229 0.9 2.50 0.7 9.00 (sw) 2.3 1 DN25 64 0.3 229 1.0 2.50 1.2 9.00 (sw) 4.6 11/4 DN32 64 0.5 229 2.1 2.50 1.0 3.50 1.1 11/2 DN40 64 0.5 89 0.5 21/2 3% 1.3 3.3 DN20 + 0.6 + 1.5 2.50 1.1 9.50 3.5 1 DN25 64 0.5 241 1.6 3.50 3.3 3.50 1.4 11/4 DN32 89 1.5 89 0.6 2.50 3.6 9.50 (sw) 3.7 11/2 DN40 64 1.6 241 1.7 2.50 3.9 3.50 4.3 2 DNSO 64 1.8 89 2.0 3 % 1.5 4.5 DN80 DN20 + 0.7 + 2.0 1 2.50 1.3 9.50 (sw) 4.8 DN25 64 0.6 241 2.2 2.50 1.4 4.8 11/4 DN32 64 0.6 + 2.2 11/2 2.50 5.1 9.50 (sw) 5.1 DN40 64 2.3 241 2.3 2.50 1.6 3.50 6.0 2 DNSO 64 0.7 89 2.7 2.50 1.8 3.50 7.0 21/2 64 0.8 89 3.2 DN65 2.50 2.1 64 1.0 31/2 3 2.50 2.0 9.50 (sw) 7.0 DN90 DN80 64 0.9 241 3.2 4 1 3.00 3.0 13.00 (sw) 6.5 DN100 DN25 76 1.4 330 2.9 No. 50 Concentric No. 51 Size Reducer Eccentric Reducer Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb inches lb DN mm kg mm kg 1¼ DN32 + 4.6 2,1 - 3.00 (sw) 2.6 10.00 (sw) 8.1 11/2 DN40 76 1.2 254 3.7 2 3.00 2.4 4.00 3.3 DN50 76 1.1 102 1.5 3.00 2.7 4.00 3.4 21/2 76 1.2 102 1.5 3 3.00 3.2 4.00 3.5 DN80 76 1.4 102 1.6 3.00 2.9 10.00 (sw) 8.0 31/2 DN90 76 1.3 254 3.6 5 2 DNSO 11.00 (sw) 279 9.0 4.1 11.00 (sw) 279 5.2 2.4 4.00 4.3 11.00 (sw) 10.8 21/2 102 2.0 279 4.9 4.00 5.5 11.00(5w) 11.1 3 DN80 102 2.5 279 5.0 4 3.50 4.3 5.00 12.0 DN100 89 1.9 127 5.4 6 1 DN150 DN25 4.00 102 5.0 2.3 11.50 (sw) 292 14.5 6.6 1½ DN40 + 5.5 2.5 + + 4.00 6.6 11.50 (sw) 14.5 2 DN50 102 3.0 292 6.6 4.00 6.4 11.50 (sw) 14.2 21/2 102 2.9 292 6.4 3 4.00 6.4 5.50 15.0 DN80 102 2.9 140 6.8 4 4.00 6.5 5.50 17.0 DN100 102 2.9 140 7.7 4.00 6.4 5.50 17.0 5 102 2.9 140 7.7 8 21/2 DN200 16.00 406 7.9 3.6 12.00 (sw) 305 26.1 11.8 5.00 9.3 12.00 (sw) 22.0 3 DN80 127 4.2 305 10.0 5.00 10.4 12.00 (sw) 23.0 4 DN100 127 4.8 305 10.4 5.00 11.6 12.00 (sw) 23.0 5 127 5.2 305 10.4 6 5.00 11.9 6.00 24.0 DN150 127 5.4 152 10.9 07.01 1449 Rev AF Updated 08/2017 © 2017 Victaulic company. All rights reserved. a, ILIJLI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N STYLE 920 cnoss PATENTED Mechanical-I® STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 9201\ housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/-i-82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "I" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER System No. Location uiww jirt,iiIir f-nm CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved Date Para___________ I DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½°/50 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size . IimfliL.J,. UDIA1r I AI 8x3x 1fl1i tflI3 IIii1iii I1ii = j I 2 ½ (a) ° X 920¼ 500 1.50 2.00 2.53 - 1.61 5.35 2.75 3.1 - 50 51 J 64 . L 136 _2_ _1.5 1.61 5.35 2.75 3.1 ~(a)o 920N 500 1.50 1.97f 2.53 20 J3450 38 9, 4 1.5 1(a) N 1 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 920 3450 38.1 47 64 . 41 136 70 1.4 1.75 3.00 3.5 3.2 TIK (a) t- 32 920N 500 2.05 2.75 3.00 1.61 5.35 3450 44.5 52 70 76 41 136 76 1.7 1.5 1½ (a) to 500 920N 2.03 T 2.75 1.61 1.75 3.12 5.35 3.25 3.6 3.2 40 3450 - I 500 44.5 - I 1.50 52 70 79 41 136 83 1.7 1.5 21/2 ½ a) §o 2.21 2.74 1.82 5.64 2.75 3.0 65 X _15 92oNj so 70 zI. 3/4 a) §o 920N 1 500 ri- 1 .50 2.18 2.74 1.82 5.64 2.75 3.0 20 34508.1 4. 55 70 - 46 143 70 1.4 - 1.82 5.64 2,75 1(a) §o 500 920N 1.50 2.06 2.74 2.9 25 j 3450 38.1 52 70 - 46 143 70 1.4 - 1¼ t (a) 500 920N 3.2 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 2.28 3.00 3.25 3.25 3.6 3.3 1½ t (a) 920N '• 500 0 2.00 1.82 6.26 40 L 3450 920 N 300 50.8 58 76 83 46 159 83 1.7 1.6 761 x 1/2 (a) 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 , 2065 38.1 56 70 - 57 164 81 1.8 - 2.75 2.25 Y4 (a) 300 920N 1.50 2.19 6.46 3.18 3.9 20 2065 38.1 56 70 - 57 164 81 1.8 - 1.50 2.07 2.75 6.46 3.18 3.8 1(a) 920N 300 2.25 25 2065 38.1 53 70 - 57 164 81 1.7 - 1 1/4 (a)0 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2 (a) 0 920N 500 2.00 2.28 3.00 6.29 3.25 3.5 3.3 3.31 1.92 40 920N 3450 500 50.8 58 76 2.52 3.05 84 49 2.28 160 6.15 83 1.6 1.5 3 1/2 (a) a 1.50 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 1 70 1.6 - 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 '/4 (a) a - 20 3450 38.1 63 78 58 156 70 1.6 - 920N 500 1.50 2.28 6.15 2.75 3.3 1(a) 2.38 3.06 25 3450 38.1 61 78 58 156 70 1.6 - 920N 500 1.75 3.56 2.28 6.15 3.00 3.8 3.7 1 ¼ (a) to 2.55 3.25 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 2.00 3.50 3.56 6.15 3.25 4.1 1 1h a) to 920¼ 500 2.78 2.28 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 920N 500 3.50 3.56 2.28 3.88 4.9 4.6 2(3)0 2.50 2.75 6.75 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3½ 2 920N 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 90 50 3450 63.5 76 - 95 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 * Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 1- Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www uirl,,,Iir rAm . DIMENSIONS y--1 z F6,411t GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N e a Work Iajh,H.Ja, Approx. Weight Each • II Im MA TABLE CONTINUED FROM PAGE 2 4 ½ (a) a > 920N 500 1.50 3.03 3.56 2,69 7.01 2.75 3.7 100 15 3450 38.1 77 90 - 68 178 70 1.8 ~ (a) a 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 - 1.8 1(a) a 500 920N 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 1 - 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 1% (a) ta 920N 500 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2 (a) to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2(a) to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 2112 (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 920 2.75 2.88 4.00 2.69 7.34 4.63 6.4 761 mm 500 3450 69.9 73 - 102 68 186 118 - 2.9 3(a) t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6,4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 11/4 (a)a 108.0 x 920N 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 32 3450 44.5 78 96 - 67 194 78 - 2.3 1 1½ (a)a 920N 500 2.00 3.28 4,00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 - 67 194 83 - 2.3 2 (a) 920N 500 2.50 3.25 4.00 2.63 764 4.00 4.0 * 50 3450 63.5 83 12 L J. 102 -1.9 761 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 1 7.8 3450 69.9 73 102 102 67 194 109 3.6 [ 3.5 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 1112 (a) t 920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 1 50.8 102 121 121 80 246 94 1 3.4 3.4 2(a) t 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 21/2 (a) t 920 500 2.75 3.63 4.75 4.75 3,16 9,70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 761 mm c 920 2 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 3450 69.9 95 - 121 80 246 118 - 3.6 3(a) t 9 0 2 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 133.0 x 920N 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 50 3450 63.5 95 114 - 81 203 99 - 3.6 3 920 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 3450 88.9 97 127 - 76 240 135 - 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: * Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. 4 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. u,wu, uirtauulir mm DIMENSIONS y -::jl r -r- z 64 It GROOVED OUTLET FEMALE THREADED OUTLET IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size • PjIOli.1t.h D pv 11aitI Vimt1 I1 0 3 -.. Uiifl I = G TABLE CONTINUED FROM PAGE 3 1397 x 11/2 t 920N 500 2.00 3.78 I 4.50 3.30 8.23 3.25 7.0 40 -- j 3450 50.8 96f 114j 84 - 209 83 3.2 - 500 2.50 8.23 - 2t 920N 3.75 4.50 3.30 3.88 9.0 50 920N j_ 3450 500 63.5 1.75 95 r 4.43 114 5.13 1 - 5.13 84 209 99 4.1 - 6 11/4 (3) 3.79 9.15 3.25 5.1 4.8 150 32(b) 3450 44.5 112 , 130 130 96 232 83 2.3 2.2 1 ½ (a) In 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2 .a) to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 2½ 920 2.75 500 4,01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 118__3.8 3.4 500 5.21 3.69 10.51 4.63 ' 8.4 761 mm 920 2.75 4. 15 3450 I 69.9 - 105 132 94 267 118 - 3.8 3(a) t 920 4---- 500 -I----. 3.50 t ... 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 1 110 140 130 94 267 135 4.5 3.8 3.69 10.51 6.25 10.1 10.1 4(a) to 920 1 500 4.50 3.81 ' 5.75 5.38 100 920N 3450 500 114.3 2.00 97 146 4.41 5.13 L137 94 267 9.40 159 4.6 7.8 4.6 1590 1 ½ 3.63 3.25 40 3450 50.8 112 130 - 92 239 83 3.5 500 4.38 5.13 3.63 9.40 3.88 8.0 2(a) 920N 2.50 50 3450 63.5 111 130 - 92 239 99 3.6 500 5.50 3.63 4.63 9.5 761 mm 920 2.75 4.38 5.13 9.40 ' 3450 69.9 111 140 130 92 239 118 4.3 4.3 5.13 3.63 9.40 5.31 1 8.1 14.0 920 500 3.50 4.31 5.50 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 5.38 3.63 9.40 6.12 1080mm 920 500 4.50 4.45 10.0 3450 114.3 113 - 137 92 239 155 - 4.5 4.50 3.81 5.75 3.63 9.40 6.25 18.0 - 920 500 00 3450 114.3 96.80 146 - 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. I Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT' clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services n LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. wwu, uirf,uulir mm / CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS y r-r Z F 64- v -- 1. 11 GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2"/50 x 15mm through 8 x 4/200 x 100 mm Dimensions Weight Each I TABLE CONTINUED FROM PAGE 4 1 165.1 x 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 116 - 96 237 70 3.6 - 1 Iflo 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 - 32 3450 44.5 113 130 - 96 237 83 3.8 1½ (a) tn 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2(a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 761 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3 (a) t 0 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4(a) to 920 500 4.50 3.81 5.75 5,38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2(a) t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 1 316 114 1 5.3 1 5.3 2½ (a) 1 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm 920 500 2.75 5.25 6.25 4,81 12,42 4.56 11.6 3450 69.9 133 - 159 122 316 116 - 5.3 3(a) ID 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4(a) ID 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 1 162 1 122 1 316 1 159 1 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. 1 Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. WtMW uirt2iilir mn, I' CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°FI+16°C are shown in the table below. Formulas for C,K. Values: = Q2 C 2 Q = C x Where: Q = Flow (GPM) = Pressure Drop (psi) C = Flow Coefficient Where: 0 = Flow (m3/hr) AP = Pressure Drop (Bar) K =Flow Coefficient Exaggeiated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213, - .1 1IIlII1r4 maw (C 120A FT C,1K, Values ½ 0.840 11 - 2 - 15 21.3 -"-. 9.4 3/4 - 1.050 - 16 - 20 26.7 1.315 - 13.7 1 21 3 8 25 337 1.660 - 1.8 48 1¼ 50 32 42.7 1.900 5 /2 11 6 42.9 41.1 53 1 112 11 -53 40 48.3 2.375 45.4 45.4 104 - 2 112 50 60.3 2.875 9 10/2 12½1 96 89.1 150 21/2 119 65 73.0 20 102 128.5 3.000 * 161 76.1 mm 16 - - 3 3.500 249 237 80 88.9 14 15 /2 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 Hazen-Williams coefficient of friction is 120. * Pipe with a wall thickness of 0.165inJ4.2mm. 1 FireLock Innovative Groove System (lGS) outlet mww ,iirt,i,Iir mm / CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size .r Approval Agency , .875 -6625 21/2-6 2.875 -6.62 5 ' All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875 - 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 - 1599 232 2496 21/2-4 2.875 -4.500 All SF 300 300 300 290 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1 1999 1599 2496 6 6.625 34 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 - - - 145 - 200 219.1 2755 1000 8 8.625 34 10 300 - 250 - 145 - 200 219.1 2065 1724 1000 8 8.625 34 3040 300 - 300 - 145 - 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 87100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 57125mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 2 ½/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. WWM uirtalllir mm Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com / Victaulic® FireLockTM Outlet-T jttuIicr Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes 11/4 -2 1/2'/DN32—DN65 Threaded Outlet Sizes: 1/2"/DN15, 3/4 /DN20, and 1'/DN25 NOTE IGS Grooved 1'/DN25 Outlets available for this product. See oublication 10.54. Maximum Working Pressure 300 psi/2068kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material o Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com N victaulic.com S 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) LI Orange enamel (North America, Latin America, Asia Pacific). LI Red enamel (Europe). O Optional: Contact Victaulic with your requirements for other coatings. Gasket': LI Grade "E" EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: LI Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). S S 10.52 3355 Rev H updated 06/2018 0 2018 Victaulic company. All rights reserved. victaulic.com 4.0 DIMENSIONS Style 922 Style 922 Size - Bolt/Nut Dimensions Weight Nominal Actual Approximate Run x Branch FPF Outside Diameter Qty. Size T3 V W Y Z (Each) inches inches inches inches inches inches inches inches lb DN mm - mm mm mm mm mm mm kg 11/4 1/2 1.660 0.840 2 1 x 1.30 1,83 1.10 3.87 2.56 1 DN32 DN15 42.4 21.3 47 28 98 65 0.5 2 X 1 1.28 1.83 1.10 3.87 2.56 1 3/4 1.050 DN20 26.9 33 47 28 98 65 0.5 2 1xil 1.52 2.18 1.10 3.87 2.56 1 1 1.315 DN25 33.7 39 55 28 98 65 0.5 11/2 1/2 1.900 0.840 2 x1 1.42 1.95 1.22 4.08 2.56 1 40 DN15 48.3 21.3 36 50 31 104 65 0.5 1.40 1.95 1.22 4.08 2.56 1 3/4 1.050 DN20 26.9 2 h 1 36 50 31 104 65 0.5 1.64 2.30 1.22 4.08 2.56 1 1 1.315 DN25 2 hi 42 58 31 104 65 0.6 2 1/2 2.375 0.840 1.66 2.19 1.46 4.60 2.56 1 50 DN15 60.3 21.3 2 1xil 42 56 37 117 65 0.6 1.64 2.19 1.46 4.60 2.56 1 3/4 1.050 DN20 26.9 2 hi 42 56 37 117 65 0.6 2 hi 1.88 2.54 1.46 4.60 2.56 2 1 1.315 0N25 48 65 37 117 65 0.7 21/2 ½ 2.875 0.840 2 x1 1.91 2.44 1.71 5.40 2.56 2 DN15 73.0 21.3 49 62 43 137 65 0.7 1.89 2.44 1.71 5.40 2.56 2 3/4 1.050 DN20 26.9 2 X 1 48 62 43 137 65 0.7 2.13 2.79 1.71 5.40 2.56 2 1 1.315 DN25 33.7 2 hil 54 71 43 137 65 0.7 DN65 1/2 3.000 0.840 1.91 244 1.71 5.50 2.56 2 DN15 76.1 21.3 2 h134 49 62 43 140 65 0.7 1.89 2.44 1.71 5.50 2.56 2 3/4 1.050 DN20 26.9 2 1X11 48 62 43 140 65 0.7 2.13 2.79 1.71 5.50 2.56 2 1 1.315 DN25 2 hi 54 71 43 140 65 0.8 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads Only. Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). 10.52 3355 Rev H Updated 06/2018 0 2018 Victaulic Company. All rights reserved. 5.0 PERFORMANCE Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)4 Run Size x Outlet Size Threaded Grooved5 inches feet feet DN meters meters 11/4 1 8.5 12.5 DN32 DN25 2.6 3.8 11/2 1 8.5 12.5 DN40 DN25 2.6 3.8 2 1 8.5 12.5 DN50 DN25 2.6 3,8 21/2 1 8.5 12.5 DN25 2.6 3.8 1 8.5 12.5 DN65 DN25 2.6 3.8 Hazen-Williams coefficient of friction is 120. Y FireLockTM Innovative Groove System (IGS) outlet 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter! Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm . All Outlet Sizes 1(6 1¼ 30 32 L I 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 7.1 REFERENCE MATERIALS Size ServicesPressures per Regulatory Approvals and Listings6 Nominal UL ULC FM VdS LPCB CNBOP inches psi psi psi psi psi psi DIN kPa kPa kPa kPa kPa kPa 1 Y4X½ 300 300 300 232 232 232 DN32XDN15 2068 2068 2068 1600 1600 1600 1 ¼x 3/4 300 300 300 232 232 232 DN32XDN20 2068 2068 2068 1600 1600 1600 1 1/4 x1 300 300 300 232 232 232 DN32XDN25 2068 2068 2068 1600 1600 1600 1½x½ 300 300 300 232 232 232 DN40XDN15 2068 2068 2068 1600 1600 1600 1½x3/4 300 300 300 232 232 232 DN40XDN20 2068 2068 2068 1600 1600 1600 1½x1 300 300 300 232 232 232 DN40XDN25 2068 2068 2068 1600 1600 1600 2x½ 300 300 300 232 232 232 DN50XDN15 2068 2068 2068 1600 1600 1600 2x3/4 300 300 300 232 232 232 DN50X20 2068 2068 2068 1600 1600 1600 2x1 300 300 300 232 232 232 DN50XDN25 2068 2068 2068 1600 1600 1600 2½x½ 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2½x3/4 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2½x1 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 300 232 232 232 DN65XDN15 - - 2068 1600 1600 1600 300 232 232 232 DN65XDN20 - - 2068 1600 1600 1600 300 232 232 232 DN65XDN25 - - 2068 1600 1600 1600 6 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05,01: Victaulic Seal Selection Guide 29.01: Victaulic Terms and Conditions of Sale 1-100: Installation Instructions 1-922: Installation Instructions FireLockTM Outlet-T User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer, Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the united States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on WeChat. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. if i/i Fire Products Division of Anvr International wwwanviistar.com / MERI1 J1E thiu - Type Merit Quantity 47 Outlet Size Header Size 1' Weight End Tee-Let 4747 Always Column "A" Insert size Sch. 10 A - Female Thread order a few of Chart consolidation Standard B - Male Thread more thai from Column C - Cut Groove actually "B" of chart. C/R - Roll Groove required for the job. Quantity Part Number Steel Material ~AMERM WeIdMiserTM Tee-Let® Welding Outlet Fittings Unified DesignTM Series I Merits Unified Design Series carries all important design considerations into its entire line of welding branch outlet fittings. Merit® Weld_MiserlM Tee-Lets® are designed and Manufactured to reduce the amount of weld required to install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the installation. Merit Tee-Lets install with less I weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: - - -- - - The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: I The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or I main thereby insuring complete penetration without cold welds, weld roll-off, burn-through or excessive distortion. On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from damage during shipping and handling prior to installation as well as from weld distortion. Each outlet size 11/2 and larger, whether male or female threaded, cut grooved or beveled requires the same hole size in the header pipe. This simplifies the installation process. General Specifications Tee-Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to install Merit Tee-Lets. Threads are cut in accordance with the requirements of ANSI B1.20.1, national standard for tapered pipe threads, or ISO-7-1 threads are available. Tee-Let threaded and grooved welding outlet fittings are UL/ULC Listed and FM Approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA Bulletin 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures in other non-critical piping systems. Tee-Lets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. Merit® WeldMiserTM Tee-Lets® are identified by a lot number that provides full traceability per ISO 9000 specifications. For Your Piping Systems Specify Weld-Miser TM Tee-Let® Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI B1.20.1, or 150-7-1, and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA, Bulletin 13 and pressure rated for 300 PSI maximum. How to Order - Use either of the following methods for ordering Merit® WeIdMiserTM Tee-Let®. Method No. 1 Method No. 2 Specify quantity desired followed by the part Use the following system: number shown in the "dimensions" chart for the type and size of outlet desired. -2- AMLar Fire Products Division ii• WeIdMiserTM Tee-Let® Welding Outlet Fittings For Fire Protection & Other Low Pressure Piping Systems Merit Weld-Miser1M Tee-Let® Welding Branch Outlet Fittings offer the user a high strength, low cost forged threaded.and grooved line of fittings spe- cifically designed and manufactured to be installed on Schedules 5 thru 10, proprietary thin wall flow pipe and standard wall pipe. Merit Tee-Lets are forged steel welding outlet fittings. The material used in manufacture meets the chemical and physical requirements of ASTM A 53, Grades A or B, Type E, A-135, A-795, Tee-Lets employ a low weld volume design to provide for either a partial or full penetration weld employing a single pass with minimum burn-through and pipe distortion. Weld Miser Tee-Lets are recommended for use on proprietary thin wall, Schedules 5, 10 and 40 pipe. Threads comply with ANSI B1.20.1 or 1507/1. They are UL Listed and FM Approved for use conforming to the requirements of Bulletin 131999 of the National Fire Protection Association. When used in fire sprinkler systems, Tee-Lets are rated for 300 psi. When used in mechanical systems, maximum pressures are calculated using criteria de- veloped for ASME B31 piping code. k~~g APPROVED For listing/approval details contact your AnviISta,' Representative. TEE-LET WE LDED il ETfl1FITTING I1(UL I!I P'4I EX6032, FM APPROVAL C1I1iT1I11 i PIPE iiiiiiei Outlet Model Outlet Pipe Size Header Pipe Size Rated Pressure (Inch) (Inch) (psig) 1/2 /4,1 ½ -8 (Sch.10, 40) 1/2 4 (Sch. 5, DynaFlow) Tee-Let Type A 11/4,11/2,2, 2½, 3 4 300 2 4 (EZ-Flow) (F-Threaded End) 2,4 6 (EZ-Flow) Tee-Let Type c 11/4.8 11/4.8 (Sch.10, 40) (Grooved End) 300 21/2.8 ½.4 (Sch. 5, DynaFlow) Tee-Let Type dR 11/4.6 11/4.8 (All Schedules) 300 (Roll _Grooved _End) Size-on-size (i.e. 2 x 2) Tee-Lets are not FM Approved. FM rated working pressure when welded on Sch. 5 or non-threadable lightwall pipe is 175 psi. INVtLStar Fire Products Division Type A Female Threa -----;----B WeIdMiserTM Tee-Let® Welding Outlet Fittings _ Part _ 7AB nal !Le7ngthDia Inside Make Weight Number er meter Up Each D M NPT(BSPT) In (mm) In (mm) In (mm) In (mm) In (mm) Lb. (kg) 1002002 1/4 X 11/4 8 0.080 - 6x 6-200 0.04 1005012 11/4 1½ 1.063 0.700 0.500 0.171 - 32-40 27.0 17.8 12.7 0.08 1005015 1½-2 1.063 0.700 0.500 0.171 - 1A 13x 40-50 27.0 17.8 12.7 0.08 1005020 2- 2½ 1.063 0.700 0.500 0.171 - 50-65 27.0 17.8 1 12.7 0.08 1005025 2½-8 1.063 0.700 0.500 0.169 65-200 27.0 17.8 12.7 0.08 1007012 11/4 -1½ 1.125 0.900 0.500 0.260 - 32-40 28.6 22.9 12.7 0.12 1007015 11h -2 1.125 0.900 0.500 0.260 - 3/4 X 19x 40-50 28.6 22.9 12.7 0.12 1007020 2- 2½ 1.125 0.900 0.500 0.260 - 50-65 28.6 22.9 12.7 0.12 1007025 2½ -8 1.125 0.900 0.500 0.256 - 85-200 28.6 22.9 12.7 0.12 1010012 11/4 - 1½ 1.250 1.145 0.500 0.331 1110012 32-40 31.8 29.1 12.7 0.15 1010015 1½-2 1.250 1.145 0.500 0.331 1110015 40-50 31.8 29.1 12.7 0.15 1010020 2- 2½ 1.250 1.145 0.500 0.320 1110020 1 x 25x 50-65 31.8 29.1 1 12.7 0.15 1010025 2½ -3 1.250 1.145 0.500 0.314 1110025 65-80 31.8 29.1 12.7 0.14 1010030 3-4 1.250 1.145 0.500 0.309 1110030 80-100 31.8 29.1 12.7 0.14 1010050 5-8 1.250 1.145 0.500 0.291 1110050 125-200 31.8 29.1 12.7 0.13 1012012 11/4 - 1½ 1.375 1.490 0.500 0.432 1112012 32-40 34.9 1 37.8 12.7 1 .019 1012015 11h -2 1.375 1.490 0.500 0.421 1112015 40-50 34.9 37.8 12.7 .019 1012020 2-2½ 1.375 1.490 0.500 0.421 1112020 11/4 X 32x 50-65 34.9 37.8 12.7 .019 1012025 2½-3 1.375 1.490 0.500 0.411 1112025 65-80 34.9 37.8 12.7 .019 1012030 3-4 1.375 1.490 0.500 0.389 1112030 80-100 34.9 37.8 12.7 .018 1012050 5-8 1.375 1.490 0.500 0.389 1112050 125-200 34.9 37.8 12.7 .018 1015015 1½ 1.625 1.610 0.875 0.477 1115015 40 41.3 40.9 1 22.2 .022 1015020 2 1.625 1.610 0.875 0.477 1115020 11x 50 41.3 40.9 22.2 .022 1015025 21h 1.625 1.610 0.875 0.477 1115025 40X 65 41.3 40.9 22.2 .022 1015030 3-4 1.625 1.610 0.875 0.477 1115030 80-100 41.3 40.9 22.2 .022 1015040 4 .1.625 1.610 0.875 0.477 1115040 100 41.3 40.9 22.2 .022 1015050 5-8 1.625 1.610 0.875 0.477 1115050 125-200 41.3 40.9 22.2 .022 . • Part Nominal Nominal Outlet Inside Make Weight Number Outlet Header Length Diameter Up Each A B C D M NPT(BSPT) In (mm) In (mm) In (mm) In (mm) In (mm) Lb.(kg) 1020020 2 1.750 2.067 0.875 j 0.857 1120020 50 44.5 52.5 22.2 0.38 1020025 21h 1.750 2.067 0.875 0.829 1120025 65 44.5 52,5 22.2 £138 1020030 3 1.750 2.067 0.875 0.829 1120030 2 x 80 44.5 52.5 22.2 0,39 1020040 4 1.750 2.067 0.875 0.800 1120040 50x 100 44.5 52.5 22.2 0.36 1020050 5 1.750 2.067 0.875 0.743 1120050 125 44.5 52.5 22.2 0.34 1020060 6 1.750 2.067 0.875 0.743 1120060 150 44.5 52.5 22.2 0.34 1020080 8 1.750 2.067 0.875 0.743 1120080 200 44.5 52.5 22.2 0.34 1025025 214 2.215 2.469 1.125 1.250 1125025 65 54.0 62.7 28.6 055 1025030 3 2.215 2.469 1.125 1.200 1125030 80 54.0 62.7 28.6 0.55 1025040 4 2.215 2.469 1.125 1.150 1125040 2½x 65x 100 54.0 62.7 28.6 0.52 1025050 5 2.215 2.469 1.125 1.150 1125050 125 54.0 62.7 28.6 0.52 1025060 6 2.215 2.469 1.125 1.150 1125080 150 54.0 62.7 28.6 0.52 1025080 8 2.215 2.469 1.125 1.150 1125080 1 200 1 54.0 62.7 28.6 0.52 1030030 3 2.500 3.068 1.500 1.750 - 80 63.5 77.9 38.1 0.79 1030040 4 2.500 3.068 1.500 1.700 - 3 x 100 63.5 77.9 38.1 0.77 1030050 5 2.500 3.068 1.500 1.700 - 80x 125 63.5 77.9 38.1 0.77 1030060 6 2.500 3.068 1.500 1.650 - 150 63.5 77.9 38.1 0.75 1030080 8 2.500 3.068 1.500 1.650 - 200 63.5 77.9 38.1 0.75 1040040 4 3.000 4.026 2.000 3.000 - 100 76.2 102.3 50.8 1.36 1040050 5 3.000 4.026 2.000 2.900 - 4x bOx 125 76.2 102.3 50.8 1.32 1040060 6 3.000 4.026 2.000 2.800 - 150 76.2 102.3 50.8 1.27 1040080 8 3.000 4.026 2.000 2.800 200 76.2 102.3 50.8 1.27 Note: Part #1002002 is not UL Listed or FM Approved. All size-on-size (i.e. 2 x 2) Tee-Lets are not FM Approved. -4- &-w- Fire Products Division lIT® Type B Male Thread Standard Weight Type C Cut Groove Standard Weight WeIdMiserTM Tee-Let® Welding Outlet Fittings WELD-MISER Tm lI' DIMENSIONS Ir,rii Male Thread Cut Nominal Outlet Nominal Header Outlet Inside Diameter Outside Diameter Wall Thickness Std Wt. Groove A B Length D E F Std. Wt. C NPT(BSPT) NPT(8SPT) In. (mm) !n.(mm) In. (mm) !n.(mm) !n.(mm) In. (mm) 1310012 2010012 1h/41½ 3 1.049 1.315 0.133 32-40 80 26.6 33.4 3.4 1310015 2010015 1½-2 3 1.049 1.315 0.133 lx 40-50 80 26.6 33.4 3.4 1310020 2010020 2-214 3 1.049 1.315 0.133 25x 50-65 80 26.5 33.4 3.4 1310025 2010025 2½-4 3 1.049 1.315 0.133 65-100 80 26.6 33.4 3.4 1310050 2010050 5 -8 3 1.049 1.315 0.133 125-200 80 26.5 33.4 3.4 1312012 2012012 11/4 3 1.368 1.660 0.140 32 80 34.7 42.2 3.6 1312015 2012015 1½ 3 1.368 1.660 0.140 11/4 X 40 80 34.7 42.2 3.6 1312020 2012020 2 -2½ 3 1.368 1.660 0.140 32x 50-65 80 34.7 42.2 3.6 1312025 2012025 3 -4 3 1.368 1.660 0.140 80-100 80 34.7 42.2 3.6 1312050 2012050 5 -8 3 1.368 1.660 0.140 125-200 80 34.7 42.2 3.6 1315015 2015015 1½ 3 1.610 1.900 0.145 40 80 40.9 48.3 3.7 1315020 2015020 2 3 1.610 1.900 0.145 1½x 50 80 40.9 48.3 3.7 1315025 2015025 21h 3 1.610 1.900 0.145 40K 65 80 40.9 48.3 3.7 1315030 2015030 3-4 3 1.610 1.900 0.145 80-100 80 40.9 48.3 3.7 1315050 2015050 5-8 3 1.610 1.900 0.145 125-200 80 40.9 48.3 3.7 1320020 2020020 2 3 2.067 2.375 0.154 50 80 52.5 60.3 3.9 1320025 2020025 2½ 3 2.067 2.375 0.154 65 80 52.5 60.3 3.9 1320030 2020030 3 3 2.067 2.375 0.154 2x 80 80 52.5 60.3 3.9 1320035 2020035 4 3 2.067 2.375 0.154 50X 100 80 52.5 60.3 3.9 1320050 2020050 5 3 2.067 2.375 0.154 125 80 52.5 60.3 3.9 1320060 2020060 6 3 2.067 2.375 0.154 150 80 52.5 60.3 3.9 1320080 2020080 8 3 2.067 2.375 0.154 200 1 80 1 52.5 1 60.3 1 3.9 Note: Tee-Lets are manufactured to fit size-on-size. that is the contoured shane on a oiven Tee-Let is made to fit oerfectiv on the first listed header size. If installed on the second header size marked on the fitting, a slight gap of approximately 1/32 will appear along the longitudinal centerline of the header. For example, a 1' x 2 - 21n Tee-Let, is a 1' outlet fitting manufactured to fit perfectly on the 2' header size listed, while leaving a 1/32' gap along the longitudinal centerline of the 21A size. If a perfect fit is required for a 214 header pipe, then a 1' x 21h - 3' Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. -5- iNvILStar Fire Products Division WeIdMiserTM Tee-Let® Type B Male Thread Welding Outlet Fittings Standard Weight Type C Cut Groove Standard Weight Type C/R Roll Groove Schedule 10 NO Male ThreadCut Nominal Nominal Outlet Inside Diameter - D Outside Wall Thickness - F Std. t. Groove Std. Rlrve Outlet Sch. 10 Header Length Standard Schedule Diameter Standard Schedule Wt. A B C Weight 10 E Weight 10 NPT(ISO-7-1) NPT(!SO-7-1) NPT (ISO-i-I) In.(mm) /P. (MM) In-(Mm) in.(mm) in. (mm) In-(Mm) In. (MM) In. (MM) 1325025 2025025 2225025 2½ 3 2.469 2.635 2.875 0.203 0.120 2125025 65 80 62.7 67.0 76.2 5.0 3.0 1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120 2125030 80 80 62.7 67.0 76.2 5.0 3.0 1325035 2025035 2225035 4 3 2.469 2.635 2.875 0.203 0.120 2125035 2½x 55x 100 80 62.7 67.0 76.2 5.0 3.0 1325050 2025050 2225050 5 3 2.469 2.635 2.875 0.203 0.120 2125050 125 80 62.7 67.0 76.2 5.0 3.0 1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120 2125060 175 80 62.7 670 76.2 5.0 3.0 1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120 2125080 200 80 62.7 67.0 76.2 5.0 3.0 1330030 2030030 2230030 3 3 3.068 3.260 3.500 0.216 0.120 80 80 78.0 83.0 88.0 5.0 3.0 1330035 2030035 2230035 31h 3 3.068 3.260 3.500 0.216 0.120 85 80 78.0 83.0 88.0 5.0 3.0 1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120 3 x BOx 100 80 78.0 83.0 88.0 5.0 3.0 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 125 80 78.0 83.0 88.0 5.0 1 3.0 1330060 2030060 2230060 6 3 3.068 3.260 3.500 0.216 0.120 150 80 78.0 83.0 88.0 5.0 3.0 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0.120 200 80 78.0 83.0 88.0 1 5.0 3.0 1340040 2040040 2240040 4 4 4.026 4.260 4.500 0.237 0.120 100 100 102.0 108.0 114.0 6.0 3.0 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120 4x bOx 125 100 102.0 108.0 114.0 6.0 3.0 1340060 2040060 2240060 6 4 4.026 4.260 4.500 0.237 0.120 150 100 102.0 108.0 114.0 6.0 3.0 1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120 200 100 102.0 108.0 114.0 6.0 3.0 - 2060060 2260060 6 4 6.065 6.357 6.625 0.280 0.134 6 x 150 150 100 155.0 161.5 168.3 71 3.0 - 2060080 2260080 8 4 6.065 6.357 6.625 0.280 0.134 200 100 155.0 161.5 168.3 71 3.0 - 2080080 - 8 x 8 4 7.981 8.329 8.625 0.322 0.148 ___________ 200x 200 100 203.0 212.0 213.0 8.0 3.0 Note: Tee-Lets are manufactured to fit size-on-size, that is the contoured shape on a given Tee-Let is made to fit perfectly on the first listed header size. If installed on the second header size marked on the fitting, a slight gap of approximately 1,J2" will appear along the longitudinal centerline of the header. For example, a lx 2 - 21,' Tee-Let, is a 1 outlet fitting manufactured to fit perfectly on the 2 header size listed, while leaving a 142 gap along the longitudinal centerline of the 21& size. If a perfect fit is required for a 21/2 header pipe, then a lx 2½ - 3 Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. -6- Fire Products Division UT® Threading Practice WeldMiserTM Tee-Let® El10otivo Thread L2 MIThLLI_0 UVM Ia Pp pizh Me of thread MERIT NPT THREAD FORM Wrand Vanish Pilch VaLl. Pi a Standard WP dn~l leaves 8~ xUas thsn.l. on L3 ftea&. STANDARD NPTTHREAD FORM Installation Welding Outlet Fittings EPT TAPEREDiPIPE r Drop Nipple Li 13 Total L2 or Tee-Let Hand Tight Wrench Tight Li - L3 Effective Outlet Size Lenoth Threads In.finm) Injimm Threads In.mm Threads fjym Threads Threads 1/2" 0.320 448 0.214 300 0.534 7.48 0.534 7.47 15 81 5A -13.6 3/4" 0.339 4Th 0.214 300 0.553 7.75 0.546 7.64 20 8.6 5A -13.9 _ 0.400 460 0.261 300 0.661 7.60 0*683 7.85 25 W2 -17.3 11/4 0.420 483 0.261 300 0.681 7.83 0.707 8.13 32 10.7 6.6 1Z3 -18.0 1½" 0.420 4.83 0.261 300 0.697 7.83 724 &32 40 12L 18.4-_ - 0.436 5.01 0.261 3.00 0.706 8.01 0.757 870 50 J1L_ - 179 - iL 21h" _ 0.682 5 46 0.250 2 00 0.932 7. 46 9.10 65 1 87.3 ...&2L - 3 0.766 0.250 200 1.016 8.13 1.200 9.60 80 . 25.8 30.5 4 0.844 675 0.250 2 1.094 ¶40 100 21.4 - 2 330- Domestic Manufacture Increasingly, federal, state, municipal, and quasi municipal authorities require domestic content for fire sprinkler systems. Merit® Tee-Lets® meet these requirements. The need to maintain dual inventories; one domestic; one import is eliminated. Welding Practice Tee-Let® thread form is consistent with Aeronautical National Form (ANPT) AS71051. The thread is fully formed over both the L-1 hand tight and L-3 wrench tight threads. NPT tapered threads are typically gauged only over the L-1 threads. This makes Tee-Lets more forgiv- ing of field cut threaded pipe that may only marginally conform to the specification. Fewer leaks translate into lower costs. Ease of Installation Merit Manufacturing Tee-Lets are designed to sit higher on the pipe, thereby requiring less weld and eliminating burn through. Tee-Lets sit higher on the header or branch line pipe than competitive fittings. This allows the welding torch to remain in an optimum position for welding. In addition, 11& and larger Type A female threaded and Type C grooved Tee-Lets require the same hole size for installation. This re- sults in fewer change overs when installed using automatic welders. When measured with respect to linear inches of weld required for installation, Tee-Lets require up to 15% less weld than competitive fittings. This reduces time and savings over time are substantial. The diameter of the contoured end of Type A Tee-Lets has been reduced so that the wall thickness more nearly matches the header or branch line pipe wall thickness. Therefore, current and voltage settings required for welding are set to provide for adequate penetration without burn through and cold shutting. Also, weld volume required for installation is lower for Tee-Lets than most other fittings. Typically, Tee-Lets re- quire one-weld pass for attachment. 2.820' - .325 -I 2" Competitive Fitting 2" Merit Weld-Miser Tee-Let WELDING M'lF'4: Outlet MERIT WELD-MISER TEE-LET COMPETITIVE FITTING WELD VOLUME* LINEAR WELDING WELD VOLUME* LINEAR WELDING Size In. (mm) Cross Sec. Area %Iess In. (mm) %Iess Cross Sec. Area %more In. (mm) %Iess 0.051 sq. in. 2.48 0.058 sq. in. 2.48 0% 25 32.9 sgmm 12% 62.9 0% 374sgmrn 12% 62.9 11/4' 0.032" 48% 2.88 4% 0.063 48% 3. 01 4% 32 20.6 73.1 40.6 76.4 11/2" 0.036" 3.12 0.060 3. 46 40% 10% 40% 10% 40 23.2 1 79.2 1 38.7 87.8 0.040" 3.77 0.106 4.41 62% 15% 62% 15% 50 1 25.8 95.7 68.3 1 112.0 ANVft.Star -7- Fire Products Division OCKM Rib - 1fl!1iF Tee-Let Size Type Recommended Hole Size In/mm In/mm ½ Type 5% 13 16 3/4 Type 7% 19 22 1 Type 25 28 1Y4 Type 1½ 31 38 11/4 Type 13/s 31 35 1½ Type AorC 1/8 38 41 2 Type AorC 2 50 50 21h Type AorC 27A6 63 61 3 Type AorC 3 75 75 4 Type AorC 4 100 100 Holes may be cut employing mechanical means—including hole sawing, mechanical flame cutting (oxy-acetylene or propane), and air plasma cutting (constricted tungsten arc) machines. Merit otters a simple approach to cut- ting the hole. Hand-held templates are sized to match your plasma cutter. Y 2,3/4&lOutlet WeIdMiserTM Tee-Let® Installation (cont.) Welding Outlet Fittings Recommended Installation Procedures Merit Weld-Miser Tee-Let Welding Outlet Fittings are designed and manufactured to reduce the cost of installa- tion from both the standpoint of labor required and energy consumed. In addition, by following the recommended in- stallation procedures, many of the problems associated with installing welding outlet fittings on standard weight or light weight pipe are eliminated, including burn through and excessive shrinkage resulting in pipe distortion. Recommended Hole Sizes The hole cut in the branch or header pipe can be cut prior or sub- sequent to attachment of the Tee-Let. One advantage of culling the hole after welding is that the pipe is left intact during welding thereby reducing shrinkage and possible distortion. If holes are cut prior to welding, as some codes require, then the following hole sizes are recommended. Note that the same hole diameter for a given outlet size is required for both Type A and Type C Tee-Lets 1-1'/2" larger. Recommended Welding Procedures Merit Weld-Wiser Tee-Lets are designed to be installed on standard weight or light weight pipe with one weld pass on Type A outlet sizes from 1/20 through 21/2 inclu- sive, and on Type C outlet sizes through 4". Moreover, the wall thickness at the weld end of the fitting approximately matches standard weight pipe. Accordingly, heat setting can be made to optimize penetration on both the filling and the pipe which it is being welded. Aside from reducing the likelihood of burn through and distortion resulting from excessive heat, the amount of weld' required for adequate penetration is significantly reduced. Merit Tee-Lets are manufactured from continuous cast aluminum killed steel with a carbon range of from 0.05 to 0.25. Merit specifies that residuals, such as chrome, nickel and other metals resident in the scrap used for production of the steel be reported and kept to a minimum. On the other hand, certain grades of carbon steel pipe are manufactured from skelp whose chemical composition is not speci- fied. When the metal inert gas shield (MIG) welding process is employed, certain residuals may cause excessive porosity, spatter or lack of penetration. Specifically, gases released during the welding process do not escape before the molten puddle sets up. When porosity or lack of penetration occurs, one approach is to slightly increase the heat in order to give the gases time to escape from the puddle. A flux cored wire can also be used. This wire contains scavengers which allow gases in the molten weld puddle to escape before the weld solidifies.The following recom- mended settings for welding therefore may need to be adjusted slightly higher if any of the above mentioned adverse conditions exist. As a general rule, the weld should be only as hot as required to allow the weld to penetrate the materials being welded while concomitantly allowing gases developed in the welding process to escape. Every effort must be made to avoid welding too hot or overheating both the pipe and the Tee-Let. Excessive heat may cause the wrench tight threads (those in the bottom of the Tee-Let near the weld zone) to distort while also causing the branch pipe to bend. It should be noted that Merit Tee-Lets have been subjected to exhaustive testing and evaluation, and only negli- gibly distort when subjected to excessive heat. The threads, on the other hand, may not return to their gauged form after cooling if excessive heat causes them to expand. The following is intended only as a guide, and assumes that the welding equipment is properly calibrated and functioning normally and the operator is qualified. Outlet A B Size In/mm In/mm In/mm ½ 1/4 /I6 13 1 7 5 24 1/4 3Ae 19 7 5 1 74 3As 25 7 5 1h 1% 3As 31 7 5 1'/3 1% 38 8 7 2 5A6 1/4 50 8 7 2½ 5Ao 1% 63 8 7 3 75 10 5 4 100 10 5 —8— Fire Products Division UT® WeIdMiserTM Tee-Let® Installation (cont.) Welding Outlet Fittings 1ITRECOMMENDED SETTINGS FOR MICROWIRE WELDINGIPROCESS, CONTINUED Ii!i NEXT 11 Header Size Pipe Wall Thickness Tee-Let Types A, B, C Electrode Size Welding Current Arc. Volts Wire Feed Travel Speed In/mm In/mm In/mm AMPS-DC POS. IPM IPM -2 0.035 100-130 16-20 210 25-30 0.065 13-50 2A-4 0.035 115-150 17-21 270 20-25 2 14-2 63-100 1/2 2 0.035 110-140 18-22 220 25-30 31-50 0.109 13-50 21A4 0,035 120-160 19-22 290 20-25 3 63-100 1A-2 0.035 110-140 17-20 210 20-25 0.083 13-50 21A-4 0.035 120-150 17-20 270 20-25 2.5 21,54 63-100 1/2 0.035 120-160 19-22 290 20-25 63-100 0.120 13-50 2'A-4 0.035 130-160 19-22 240 20-25 3 63-100 1iS -2 0.035 120-150 17-20 210 20-25 0.109 13-50 21,S4 0.035 130-150 18-20 270 15-20 3 63-100 V2-2 0.035 130-160 19-22 290 20-25 5-6 125-150 13-50 2S-4 0.035 140-160 20-22 270 15-20 0.134 35 63-100 2'S-4 0.045 180-205 20-24 245 27-32 63-100 1/2 - 2 0.035 120-150 17-20 240 20-25 13-50 2'/2-4 0.035 130-150 18-20 260 15-20 0.109 3 63-100 2',5-4 0.045 170-220 18-22 290 12-18 8 63-100 1,52 0.035 130-160 19-22 240 20-25 200 13-50 21½4 0.035 140-160 20-22 260 15-20 0.148 3.5 63-100 21A4 0,045 180-225 20-24 290 12-18 63-100 ________________ ________________ ________________ ________________ Shielding Gas Flow (FOR ALL SIZES) 20-25 CFH CO2 - Deeper penetration, faster welding, low cost. 25% - Argon, 75% - CO2, Recommended for .134 wall and lighter, high welding speeds without melt through, minimum distortion and spatter, good penetration. Merit assumes no liability for any consequential damages resulting from the improper use at its Tee-Let Welding Outlet Fittings, nor for any recommendations made with respect to installation procedures. /iitLStar Fire Products Division —9— INTERNATIONAL, INC. Corporate Offices 110 Corporate Drive, Suite 10' P.O. Box 3180 Portsmouth, NH 03802-3180 Tel: 603-422-8000 • Fax: 603-422-8033 E-mail address - Webmaster©anvilintl.com www.anvilintl.com For Sales and Service Information Contact the Regional Service Center Nearest You or Visit Our Website at www.anvilstar.com U.S. Regional Service Centers NORTHEAST REGION Servicing: Connecticut, Delaware, Maine, Maryland, Massachusetts, New Hampshire, New Jersey, New York, East Pennsylvania, Rhode Island, Vermont, Virginia 2530 Pearl Buck Road Bristol, PA 19007 Tel: 215-788-4056 ° Fax: 215-788-4475 Toll Free: 1-800-451-2935 MIDWEST REGION Servicing: Illinois, Indiana, Iowa, Kansas, Kentucky, Michigan, Minnesota, Missouri, Nebraska, North and South Dakota, Ohio, West Pennsylvania, West Virginia, Wisconsin 750 Central Avenue University Park, IL 60466 Tel: 708-534-1414 ° Fax: 708-534-5441 Toll Free: 1-800-301-2701 SOUTHERN REGION Servicing: Alabama, Arkansas, Colorado, Florida, Georgia, Louisiana, Mississippi, New Mexico, North and South Carolina, Oklahoma, Tennessee, Texas, Wyoming 1313 1313 Avenue R Grand Prairie, TX 75050 Tel: 972-343-9206 ° Fax: 972-641-8946 Toll Free: 1-800-451-4414 WESTERN REGION Servicing: Alaska, Arizona, California, Hawaii, Idaho, Montana, Nevada, Oregon, Utah, Washington 1385 Greg Street Sparks, NV 89431 Tel: 775-331-7029° Fax: 775-331-5075 Toll Free: 1-800-572-0051 EUROPE & MIDDLE EAST REGION Rick van Meesen, Business Director the Netherlands Tel: +31 53 5725570 Fax: +31 535725579 U.S. Customer Service Tel: +1 708 534 1414 LATIN AMERICA, PUERTO RICO & MEXICO Art Gutierrez, Sales Manager Tel: 813-300-3721 U.S. Customer Service Tel: 708-534-1414 ° Fax: 708-534-5441 Fire Products Division of Anvil® International ANVILSTAR CUSTOMER SERVICE CENTER Tel: 708-534-1414 ° Fax: 708-534-5441 Toll Free: 1-800-301-2701 #327 / Printed in USN RPI / 2.5M / 4.05 / ©2005 Anvil International, Inc. Ductile Iron Threaded Fittings :1T : J j Specifications 1 branded fittings are UL Listed anc FM Approved at 500 psi Rated tc 300 psi WSP 'U us Ductile ircn castings conform to ASTM A16 c L LISTED Fitting dimensions conform to ASME B16.3 3ushings and plugs conform to ASME B16.14 All fittings are 100% air tested APPROVED I\PT threads on all fittings conform to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & mechanical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 ProPakml Packaging Thniperature Cegrees F Working Pressure, Non-Shock psig Class 300 Threaded Fittings -20toloci 500 - 500 480 460 150 200 250 - 300 440 420 350 400 400 380 360 340 500 550 600 320 300 650 0 .LLC' :1[Uht Q i i ,i , SU ProPak System Fig. 35E 3_900 Elbow c®oS <> APPROVED LISTED I Size in Part Number A in Packing Weight lb Inner Master I 1/2 35E3004 1.13 100 200 0.2 3/4 35E3006 1.31 70 140 0,3 1 35E3010 1.50 40 80 0.5 I 1-1/4 35E 3012 1.75 25 50 0.8 I 1-1/2 35E3014 1.94 18 36 1.1 I 2 35E3020 2.25 10 20 1.8 I_2-1/2 35E3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4x1/2 35RE3006004 1.20 1.22 80 160 0.3 1x1/2 35RE3010004 1.26 1.36 70 140 OA 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 - 2 x 1-112 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 1 2.39 1 2.60 1 6 12 2.5 At. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F3004 0.88 150 300 0.2 3/4 35F3006 0.98 80 160 0.3 1 35F3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 1 25 50 0.7 1-1/2 35F3014 1.44 20 40 1.0 2 35F3020 1.69 10 20 1.6 2-1/2 35F3024 1.95 4 8 2.7 Fig. 35T3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3513004 1.13 80 160 0.3 3/4 35T3006 1.31 30 60 0.5 1 35T3010 1.50 25 50 0.7 1-1/4 35T3012 1.75 10 20 1.1 1-1/2 35T3014 1.94 10 20 1.5 2 35T3020 - 2.25 6 12 2.4 2-1/2 3513024 2.70 4 8 4.3 237 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x 1/2 35RT3006004 35R13010004 35RT3010004010 1.20 1.26 1.50 1.20 1.26 1.36 1.22 1.36 1.50 60 30 30 120 60 60 0.4 0.6 0.6 1x1/2 1x 1/2 x1 1 x3/4 1 x 3/4 x 3/4 1x 3/4 x1 35R13010006 1.38 1.38 1.31 1.45 1.45 1.45 1.50 25 35 25 50 70 50 0.6 0.6 0.7 35R13010006006 35R13010006010 1.38 1.50 1-1/4 x 1/2 1-1/4x1/2x1-1/4 35RT3012004 35RT3012004012 1.34 1.75 1.34 1.53 1.53 1.75 20 25 40 50 0.8 0.9 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 40 30 50 40 0.9 1.0 1.0 0.7 0.8 1-1/4x3/4x1-1/4 1-1/4x1 35RT3012006012 1.75 1.62 1.75 1.67 1.53 1.63 20 15 25 20 35R13012010 1.58 1.58 1-1/4 x 1 x 1/2 1-1/4x1 x 3/4 35RT3012010004 35R13012010006 1.34 1.45 1.26 1.38 1-114 x 1 x 1 35R13012010010 1.58 1.50 1.69 1.75 20 15 40 30 09 1.0 1-1/4 x x 1-1/4 35RT3012010012 1.75 1.69 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16---32, 1.0 1-1/2x1/2x1-/4 35RT3014004012 1.81 1.56 1.88 2 48 24 32 1.1 1.2 1.1 1-1/2x1/2x1-/2 35RT3014004014 1.94 1.66 1.94 12 1-1/2x3/4 35R13014006 1.52 1.52 1.75 16 1-1/2x 3/4 x1-1/4 1-1/2x3/4x1-1/2 35RT3014006012 1.94 1.66 1.75 1.88 1.94 20 18 40 36 24 40 1.1 1.2 1.2 0.8 35RT3014006014 1.94 1-1/2x1 35R13014010 35R13014010004 1.65 1.44 1.65 1.25 1.0 1.69 12 20 1-1/2x1 x1/2 1-1/2 x 1 x 3/4 35R13014010006 150 144 1.75 1.80 16 16 32 09 1.0 1-1/2x1x1 1-1/2x1 x1-1/4 35R13014010010 35R13014010012 1.65 1.82 1.50 1.67 32 1.88 12 -. 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/F 11/2x11/4x1/2 35RT3014012 1.82 1.82 1.88 12 16 24 32 1.4 09 35R13014012004 141 134 166 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 1.80 16 16 32 32 1.0 1-1/2x1-1/4 x1 35RT3014012010 1.65 1.58 1.1 1-1/2 x 1-1/4 x 1-1/4 1-1/2x1-1/4x1-1/2 35R13014012012 1.82 1.75 1.88 1.94 14 14 28_ 28 1.3 1.4 35RT3014012014 1.94 1.88 2x1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.63 1.97 10 20 1.6- 2 x 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35RT3020014 02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1 1/2x3/4 2x1-1/2x1 35RT3020014006 160 152 197 10 8 20 16 14 1.5 35RT3020014010 1.73 1.65 2.02 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 16 1.7 1.8 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 8 1 1 C US Fig. 35RT3 - Reducing Tee LISTED APPROVED Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 lx 1-1/4 35BT3010012 1.67 1.67 1.58 20 15 40 30 30 0.9 1 x 1-1/2 1-1/4x1x1-1/2 35BT3010014 1.80 1.80 1.65 1.0 1.2 35B13012010014 1,88 1.80 1.82 15 1-1/4x1-1/2 35BT3012014 1.88 2.10 1.88 2.10 1.82 1.90 15 10 30 20 1.3 1.6 1-1/4x2 35BT3012020 1-1/2 x 1-1/4 x 2 35B13014012020 35BT3014020 2.16 2.16 2.10 2.16 2.02 2.02 10 8 20 16 1.8 1.8 1-1/2x2 SMITH-COCPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 238 Fig. 35CP3 - Straight Coupling with Ribs <S> C@US APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 350P3004 1.38 1.63 200 100 400 - 200 0.1 0.2 3/4 35CF3006 1 35CP3010 1.75 60 120 0.4 1-1/4 350P3012 2.00 35 70 0.5 1-1/2 350P3014 2.19 25 50 0.7 2 350P3020 2.62 15 30 1.2 2-1/2 350P3024 3.00 9 18 2.2 Size in Part Number A in B in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 1.40 180 360 0.2 1 x3/4 35HB3010006 1.06 1.40 180 360 0.1 1-1/4x1 35HB3012010 1.19 1.80 90 180 0.2 1-1/2x 1 35HB3014010 1.25 1.95 75 150 0.4 1-1/2x 1-1/4 35HB3014012 1.25 1.95 75 150 0.3 2 x 1 35HB3020010 1.38 2.55 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 2.55 40 80 0.6 2x1-1/2 35H83020014 1.38 2.55 40 80 0.6 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35RC3010004 1.69 80 160 0.3 1x3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35R03012006 2.06 40 80 0.6 2 xT-(nothex)l 35RC3020010 2.81 1 20 40 1 1.0 Fig. 35HB3 -Hex Bushing H iI L1I 7 77 Fig. 35SP3 - Square Head Plug in I Size I Part Number ______ A in Packing Weight lb Inner Master I 1/2 35SP3004 0.94 600 1200 0.07 I 3/4 35SP3006 1.12 350 700 0.1 I 1 35SP3010 1.25 200 400 0.1 F_1-1/4 35SP3012 1.37 100 200 0.3 11-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 1 3.12 6-1 12 2.4 239 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com CQ. QUS <~> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X3020 2.25 6 12 2,8 Fig. 35X 3- Cross A A 01 Fig. 35RX3 - Reducing Cross Size in Part Number A in B in Packing Weight lb Inner Master 1-1/4x 1 35RX3012010 1.67 1.80 1.58 1.65 15 12 30 24 16 1.2 1.4 1-1/2x1 35RX3014010 2 x 1 35RX3020010 2.02 1.73 8 2.0 I MOORE U L E Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 350 3004 350 3006 0.87 0.97 300 200 600 400 220 140 100 50 0.1 0.1 0.2- 0.4 0.5 0.8 1.6 3/4 1 3503010, 1.16 110 1-1/4 35C 3012 35C 3014 35C 3020 1.28 1.33 1.45 70 50 25 - 1-1/2 2 2-1/2 3503024 1.70 18 1 36 Fig. 35BC3 - Beam Clamp Size in Part Number A in Packing Weight lb Inner I Master 3/8 35B03003 0.75 100 80 200 160 0.3 0.5 1/2 35B03004 0.75 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com 240 Victaulic FireLockTM Innovative Groove System I lGS M X, A -C —ta —U1 ii C r for 17DN25 Sprinkler Pipe 10.54 IGS TU U17, No. 142 Style 922 Style 920N No. 101 Style 108 No. 102 Style 115 Welded Outlet Outlet-T Mechanical-T Outlet Installation- Ready°° nstallation-Ready'" nstallation-Ready'°' OGS x IGS'° 90° Elbow Rigid Coupling Tee Reducing Coupling No. 148 Sprinkler No. 65 No. 144 No. 145 Female NPT No. 147 No. 143 No. 140 Reducer, NPT or Grooved End OGS x IGSTM Grooved or BSPT Threaded x Back-To-Back Close Nipple Male NPT or BSPT BSPT sprinkler outlet of Run Fitting Concentric Reducer Groove 90° Elbow sprinkler tee Threaded x Groove Adapter AMN No. 141 No. 146 Cap WB-1 NAP-1 RG2100 Roll VicFlex'° Series VicFlexr Series Female NPT or BSPT IGS'° Weld IGS'° Weld Grooving Tool AH2-CC Braided AH1-CC Braided Threaded x Groove Plunger Cone Plunger Cone Flexible Hose Flexible Hose Adapter with Captured with Captured Coupling (Refer to Zoupling (Refer to i)ublication 10.85) ublication 10.95) 1.0 PRODUCT DESCRIPTION Pipe Material Carbon steel, Schedule 10, Schedule 40. For use With alternative materials please contact Victaulic. Maximum Working Pressure o Up to 365 psi/2517 kPa/25 bar Pipe Preparation Cut (Sch. 40) or roll (Sch. 10 or Sch. 40) grooved in accordance with publication 25.14: Victaulic /GS Groove Specifications. RG2100 Grooving Capability 1°/DN25 Workstation designed to cut, ream and form a roll groove on carbon steel, Sch. 10 or Sch. 40 pipe. This tool has minimum pipe length requirement of 41/27114 mm. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location [Spec Section Paragraph Submitted By Date Approved Date p victaulic.com victaulic.com 2.0 CERTIFICATION/LISTINGS [LPCBI nVdS NOTES Approvals listed above do not apply to the R02100 Roll Grooving Tool, and the W13-1 and NAP-1 lGS' Weld Plunger Cones. 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12 Housing Coating: O Orange enamel O Red enamel (Europe) O Optional: Hot dipped galvanized Gasket: O Victaulic Grade "E" EPDM (Type A) VicPIusTM Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. NOTES: Reference should always be made to publication 1-100, Victaulic Field Installation Handbook for gasket lubrication instructions. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to publication 05.01, Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: O Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type Ill Finish No. 140, 141, 142, 143, 144, 148: Carbon steel meeting the chemical and mechanical property requirements of ASTM A53 Grade A, Type E or S No. 65, 145, 146, 147: Ductile iron conforming to ASTM A536, Grade 65-45-12 No. WB-1: Steel Alloy No. NAP-1: Aluminum Alloy RG2100 Roll Grooving Tool: Required Power Supply: Power Drive with Foot Switch (½ HP, Universal reversible motor, single-phase, 25-60 HZ) Accessories/Components: O Tool head assembly 0 Carriage assembly - accepts RG2100 tool head assembly, Standard Cutter, Standard Reamer and Standard Lever 10.54 10161 Rev G Updated 04/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS No. 142 Welded Outlet J( to Actual Inside Nominal Outside Diameter Diameter Weight inches inches Approximate DN mm 1.0. E to E (Each) inches inches lb Run x Branch Run x Branch mm mm kg 11/4 - 11/2 1.660 - 1.900 1.049 1.00 0.2 DN32 - DN40 42.4-48.3 26.6 25.4 0.1 1.049 1.00 0.2 11/2-2 1.900 - 2.375 DN40 - DN50 48.3-60.3 26.6 25.4 0.1 1.049 1.00 0.2 2-21/2 1 2.375-3.000 1.315 DN50 - DN65 DN25 60.3-76.1 33.7 26.6 25.4 0.1 1.049 1.00 0.2 21/2 -3 2.875 - 3.500 DN65- DN80 73.0-88.9 26.6 25,4 0.1 1.049 1.00 0.2 3-4 3.500 - 4.500 DN80-DN100 88.9-114.3 26.6 25.4 0.1 4.1 DIMENSIONS Style 922 Outlet-I V --~L IF 0.8 10.54 10161 Rev G Updated 04/2020 0 2020 Victaulic Company. All rights reserved. Size Bolt/Nut Dimensions Weight Actual Nominal Outside Diameter Minimum Hole Maximum inches inches Diameter/Hole Hole Diameter/ Approximate DN mm Size Saw Size Hole Saw Size Y V W Z (Each) inches inches inches inches inches inches inches lb Run x Branch Run x Branch Qty. mm mm mm mm mm mm mm kg 11/4 1.660 1/16 1¼ 4.13 1.98 1.10 2,70 1.1 DN32 42.4 2 3/8X1 3/8 30.0 32.0 105.0 50.3 27.9 68.6 0.5 1 3/16 1¼ 4.25 2.11 1.22 2.70 1.2 11/2 1.900 DN40 48.3 2 3/8x1 3/8 30.0 32.0 108.0 53.6 31.0 68.7 0.5 1 /16 1 ¼ 4.75 2.34 1.46 2.56 1.2 2 1 2.375 1.315 DN50 X DN25 60.3 X 2 /8 xl /a 30.0 32.0 120.6 59.4 37.1 65.1 0.5 1 Iia 1 ¼ 5.50 2.67 1.71 2.56 1.6 2½ 2.875 73.0 2 3/8X1 3/8 30.0 32.0 139.7 67.8 43.4 65.1 0.7 1 /i 1 ¼ 5.52 2.75 1.71 2.56 1.7 DN65 76.1 2 3/ex13/a 30.0 32.0 140.3 69.8 43.4 65.1 41411Iir rnm 4.2 DIMENSIONS Style 920N Mechanical-I Outlet Z!j " W Size Bolt/Nut Dimensions Weight Actual Nominal Outside Diameter Minimum Hole Maximium inches inches Diameter/Hole Hole Diameter/ Approximate DN mm Size Saw Size Hole Saw Size Y V W Z (Each) Run x Branch Run x Branch inches inches inches inches inches inches inches lb Qty. mm mm mm mm mm mm mm kg 3 3.500 1½ 1 6.42 3.12 2.28 2.75 2.7 DN8O 1 88.9 1.315 2 ½x 3A 38.1 41.0 163.0 79.2 57.9 69.9 1.2 4 X DN25 4.500 X 33.7 1½ 1 /a 186.6 3.62 2.69 2.75 3.0 DN100 114.3 2 ½x2~ 38.1 41.0 7.35 91.9 68.3 69.10 1.4 4.3 DIMENSIONS No. 101 Installation-Ready 900 Elbow C Size Bolt/Nut Dimensions Weight Actual Outside F Approximate Nominal Diameter Qty. Size Take Out c to E B Pre-Assembled Assembled (Each) inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm mm kg 1 1.315 3/ex2 1.25 2.13 4.25 2.75 2.75 2.2 DN25 33.7 M10x50 32 54 108 70 70 1.0 NOTE Not for use with grooved sprinklers, for grooved sprinkler connections please refer to publication 10.65 for the Style V9 sprinkler coupling. IF 10.54 10161 Rev 0 Updated 04/2020 0 2020 Victaulic Company. All rights reserved. victaulic.com p 4.4 DIMENSIONS Style 108 Installation-Ready Rigid Coupling dYB" 6YIBD Z --I- Preassembled Assembled 1 The allowable pipe end separation dimension shown is for system layout purposes only. FireLockTM Style 108 rigid couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTE Not for use with grooved sprinklers, for grooved sprinkler connections please refer to publication 10.65 for the Style V9 sprinkler coupling. Pipe End Size Separation' Bolt/Nut Dimensions Weight Actual Pre-Assembled Assembled Outside Approx Nominal Diameter Allowable Qty. Size YL YB X Z YL YB X Z (Each) inches inches inches inches inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm mm mm mm mm mm kg 1 1.315 0.14 3/8 x2 1.66 2.17 2.58 1.43 1.61 2.29 2.27 1.43 1.5 DN25 33.7 3.6 1 M10x50 42.2 55.2 65.5 36.3 41.0 58.2 57.5 36.3 0.7 4.5 DIMENSIONS No. 102 Installation-Ready Tee C Size Bolt/Nut Dimensions Weight Actual Outside F Approximate Nominal Diameter Qty. Size Take Out C to B C to R D Pre-Assembled Assembled (Each) inches inches inches inches inches inches inches inches inches lb DN mm - mm mm mm mm mm mm mm kg 1 1.315 3/8 X2 1.25 2.13 2.13 4.13 2.75 2.75 3.0 DN25 33.7 M10x50 32 54 54 105 70 70 1.4 NOTE Not for use with grooved sprinklers, for grooved sprinkler connections please refer to øublication 10.65 for the Style V9 sprinkler coupling. :em 10.54 10161 Rev G Updated 04/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com I 4.6 DIMENSIONS Pre-Assembled Assembled Pipe End Dimensions Pre-Assembled Assembled Size Separation2 Bolt/Nut Weight Actual Approximate Nominal Outside Diameter Allowable Qty. Size X Y Z X Y Z (Each) inches inches inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm mm mm mm I kg 11/4 1.660 0.14 ¼x2 3.13 4.75 1.75 2.63 4.75 1.75 1.9 DN32 1 42.4 1.315 3,6 2 M10x50 79 121 44 67 121 44 0.9 11/2 D!J25 1.900 33.7 0.14 31x2 3.25 4.88 1.75 2.88 4.88 1.75 2.1 DN40 48.3 3.6 2 M10x50 83 124 44 73 124 44 0.9 2 The allowable pipe end separation dimension shown is for system layout purposes only. FireLock" Style 115 rigid couplings are considered rigid connections and will not accommodate expansion or contraction of the pipiig system. NOTE Not for use wilh grooved sprinklers, for grooved sprinkler connections please refer to publication 10.65 for the Style V9 sprinkler coupling. 10.54 10161 Rev G Updated 04/2020 0 2020 Victaulic Company. All rights reserved. victaulic.com 4.7 DIMENSIONS r Eta E L° Length Size Threaded Outlet Size Weight Actual Outside Approximate E to E Nominal Diameter (Each) inches inches inches inches inches lb MITI ON mm DN DN kg 3 1 1.315 ½ 3/4 0.4 76 DN25 33.7 DN15 DN20 0.2 3.5 1 1.315 ½ '/4 0.5 89 DN25 33.7 DN15 DN20 0.2 4 1 1.315 ½ '/4 0.6 102 0N25 33.7 DN15 DN20 0.3 4.5 1 1.315 ½ 3/4 0.6 114 DN25 33.7 DN15 DN20 0.3 5 1 1.315 ½ 3/4 0.7 127 DN25 33.7 0N15 DN20 0.3 5.5 1 1.315 ½ 3/4 0.8 140 DN25 33.7 DN15 DN20 03 6 1 1.315 ½ 3/4 0.8 152 DN25 33.7 0N15 0N20 0.4 12 1 1.315 ½ 3/4 1.7 305 DN25 33.7 DN15 DN20 0.8 18 1 1.315 ½ 3/4 2.5 457 DN25 33.7 DN15 DN20 1.1 24 1 1.315 ½ 3/4 3.4 610 DN25 33.7 DN15 DN20 15 30 1 1.315 ½ 3/4 4.2 762 DN25 33.7 DN15 DN20 1.9 NOTE NPT or BSPT available It is acceptable to cut and groove any No. 148 longer than 67152mm. The minimum allowable cut length is 6/152mm for a No. 148. Rcduccr No. 143 Double Ended Sprinkler J o E to _il 0 Length Size Threaded Outlet Size Weight Actual Outside Approximate E to E Nominal Diameter (Each) inches inches inches inches inches lb mm DN mm DN DN kg 36 1 1.315 ½ '/4 5.0 914 DN25 33.7 DN15 0N20 2.3 NOTE 367914mm size features sprinkler outlet on both ends for field fabrication. 10.54 10161 Rev G Updated 04/2020 0 2020 Victaulic Company. All rights reserved. victaulic.com 4.8 DIMENSIONS No. 0 iS Grooved End of Run Fitting Size Dimensions Weight Actual Approximate Nominal Outside Diameter C to E (Each) inches inches inches lb DN mm mm kg 1 1/4 1.660 1.88 0.7 DN32 42.4 48 0.3 2.00 0.8 1 ½ 1.900 DN40 48.3 51 0.4 2.25 1.2 2 1 2.375 1.315 0N50 DN25 60.3 33.7 57 0.5 2.50 1.6 21/2 2.875 73.0 64 0.7 2.75 2.6 3 3.500 DN80 88.9 70 1.2 4.9 DIMENSIONS No. 144 GO GS x IGS Groovcd Conccntric Reducer ffj Size Dimensions Weight Actual Approximate Nominal Outside Diameter E to E (Each) inches inches inches lb DN mm mm kg 1 1/4 1.660 3.00 0.5 0N32 1 42.4 1.315 76 0.2 1 1/2 DN25 1.900 X 33.7 3.00 0.6 DN40 48.3 76 0.2 10.54 10161 Rev 0 Updated 04/2020 © 2020 Victaulic Conpany. All rights reserved. victaulic.com 4.10 DIMENSIONS No. 115 Female Threaded x Croove 900 Elbow Size Dimensions Weight Actual Outside Nominal Diameter inches inches Approximate DN mm C-TE inches C-GE inches (Each) lb Threaded Grooved Threaded Grooved Outlet Outlet Outlet Outlet mm mm kg ½ 0.840 1.45 1.60 0.5 DN15 21.3 36.8 40.6 0.2 1.45 36.8 1.60 40.6 0.5 0.2 3/4 1 DN20 DN25 1.050 1.315 26.9 33.7 1.50 1.60 0.5 1 1,315 DN25 1 33.7 38.1 40.6 0.2 4.11 DIMENSIONS toTE-'1-C to CtOGEH Size Dimensions Weight Nominal Actual Outside Diameter inches inches Approximate DN mm C-TE inches C-GE inches (Each) lb Threaded Threaded Grooved Threaded Threaded Grooved Outlet Outlet Outlet Outlet I Outlet I Outlet mm mm kg 1/2 ½ 1 0.840 0.840 1.315 1.75 1.60 0.7 DN15 DN15 DN25 1 21.3 x 21.3 x 33.7 44.5 40.6 0.3 NOTE: Approved for use with one or two ½" NPI Sprinklers threaded directly into outlet connection(s). 10.54 10161 Rev G Updated 04/2020 © 2020 Victaulic Company. All rights reserved. IF victaulic.com 4.12 DIMENSIONS No. 143 Close Nipple ii Size Dimensions Weight Actual Outside Approximate Nominal Diameter E to E (Each) inches inches inches lb DN mm mm kg 1.5 3 0.2 38 0.1 2 0.3 51 0.1 2.5 0.4 64 0.2 3 0.4 1 1.315 76 0.2 3.5 0.5 DN25 33.7 89 0.2 4 0.6 102 0.3 4.5 0.6 114 0.3 5 0.7 127 0.3 Bolt pad interferences may occur in some installation configurations. 4.13 DIMENSIONS No. 140 Male Threaded x Groove Adapter Ion Size Dimensions Weight Actual Outside Approximate Nominal Diameter E-E (Each) inches inches inches lb DN mm mm kg 1 1.315 2.50 0.3 DN25 33.7 63.5 0.1 No. 141 Female Threaded x Groove Adapter NO Size Dimensions Weight Actual Outside Approximate Nominal Diameter E-E (Each) inches inches inches lb DN mm mm kg 1 1.315 2.00 0.5 DN25 33.7 50.8 0.2 S 10.54 10161 Rev G Updated 04/2020 0 2020 Victauhc Company. All rights reserved. victaulic.com 4.14 DIMENSIONS No. 146 Cap iI Size Dimensions Weight Actual Outside Approximate Nominal Diameter T (Each) inches inches inches lb DN mm mm kg 1 1.315 1 0.55 j 0.2 DN25 33.7 14.0 0.1 4.15 DIMENSIONS WB-1 Weld Plunger Cone r D2--v i E to D1I Dimensions Weight Approximate E to E Dl D2 (Each) inches inches inches lb mm mm mm kg 3.75 1.63 2.00 2.2 95.3 41.3 50.8 51.0 NOTE WB-1 Weld Plunger Cones are for use with the No. 142 weld outlets and protect the groove during weld process. 4.16 DIMENSIONS NAP-i Weld Plunger Cone PT E to E Li Dimensions Weight Approximate EtoE Dl D2 (Each) inches inches inches lb mm mm mm kg 1.75 1.88 1.50 0.3 44.5 47.6 38.0 0.2 NOTE NAP-1 Weld Plunger Cones are for use with the No. 142 weld outlets and protect the groove during weld process. 10.54 10161 Rev G Updated 04/2020 0 2020 Victaulic Company. All rights reserved. If victaulic.com 4.17 DIMENSIONS RG2100 Roll Grooving Tool Tool A B C Weight inches inches inches lb mm mm mm kg 8.5 17.1 8.7 37.5 216 435 222 17.0 10.54 10161 Rev G Updated 04/2020 0 2020 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Friction Flow Data Size EquivalentLength of 1 Sch. 40 Pipe (C=120) Actual No. 102 No. 102 Nominal Outside Diameter No. 101 (Branch) (Run) Style 115 No. 148 No. 144 inches inches feet feet feet feet feet feet DIN mm Style 922 Style 920N meters meters meters meters meters meters 1 1.315 See publication See publication 2.0 5,0 2.7 DN25 33.7 LO.52 11.02 0.61 1.52 0.82 - See note 57 39 11/4 1 1.660 1.315 DN32 DN25 42.4 33.7 - - - - 1.74 - 1.19 5.0 4.3 1½ 1.900 DN4O 48.3 - - - - 1.52 - 1.31 NOTE In accordance with NFPA 13, friction loss shall be excluded for fittings directly connected to a sprinkler. For hydraulic calculations, Victaulic recommends using the installed length (E-E or cut length) of the No. 148 Sprinkler Reducer asthe equivalent length of 1'/DN25 Sch. 40 pipe. 10.54 10161 Rev G Updated 04/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE (CONTINUED) Maximum Working Pressure cULus FM LPCB VdS psi psi psi psi kPa kPa kPa kPa Style/No. bar bar bar bar 142k 365 365 365 232 2517 2517 2517 1600 25 25 25 16 922 4 300 300 365 232 2100 2100 2517 1600 21 21 25 16 920N4 365 300 365 232 2517 2100 2517 1600 25 21 25 16 1015 365 365 365 232 2517 2517 2517 1600 25 25 25 16 108 365 365 365 232 2517 2517 2517 1600 25 25 25 16 1025 365 365 365 232 2517 2517 2517 1600 25 25 25 16 115 4 365 365 365 232 2517 2517 2517 1600 25 25 25 16 148 365 365 365 232 2517 2517 2517 1600 25 25 25 16 65 365 365 365 232 2517 2517 2517 1600 25 25 25 16 144 365 365 365 232 2517 2517 2517 1600 25 25 25 16 145 365 365 365 232 2517 2517 2517 1600 25 25 25 16 147 365 365 2517 2517 N/A N/A 25 25 143 365 365 365 232 2517 2517 2517 1600 25 25 25 16 140 365 365 365 232 2517 2517 2517 1600 25 25 25 16 141 365 365 365 232 2517 2517 2517 1600 25 25 25 16 146 365 365 365 232 2517 2517 2517 1600 25 25 25 16 Maximum pressure rating is 300 psi/21 bar when installed on lightwall steel pipe, as follows: Mega-Flow and Mega-Flow-GF steel pipe manufactured by Wheatland Tube Co. Mega-Thread steel pipe manufactured by Wheatland Tube Co. MILT steel pipe manufactured by Wheatland Tube Co. WLS steel pipe manufactured by Wheatland Tube Co. Eddy Flow steel pipe manufactured by Bull Moose Tube Co. Eddythread steel pipe manufactured by Bull Moose Tube Co. EZ-Thread steel pipe manufactured by Youngstown Tube Co. Fire-Ho steel pipe manufactured by Youngstown Tube Co. Easy-Flow oipe manufactured by Borusan Mannesmann Maximum pressure rating is 300 psi / 21 bar when installed on lightwall steel pipe, as follows: Mega-Thread steel pipe manufactured by Wheatland Tube Co. MILT steel pipe manufactured by Wheatland Tube Co WLS steel pipe manufactured by Wheatland Tube Co Eddythreac steel pipe manufactured by Bull Moose Tube Co. EZ-Thread steel pipe manufactured by Youngstown Tuba Co. p 4 10.54 10161 Rev G Updated 04/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of Q o any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designers responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. A WARNING Failure to follow instructions and warnings could result in serious personal injury, property damage, and/or product damage. Ah Before operating or servicing any grooving tools, read all instructions in the manual and all warning labels on the tool. 0 1 0 • Wear safety glasses, hardhat, foot protection, and hearing protection while working around the tool. Save the operating and maintenance manual in a place accessible to all operators of the tool If you need additional copies of any literature, or if you have questions concerning the safe and proper operation of the tool, contact Victaulic, RO. Box 31, Easton, PA 18044-0031, Phone: 1-800-PICK VIC, E-Mail: pickvic@victaulic.com. 10.54 10161 Rev 0 Updated 04/2020 0 2020 Victaulic Company. All rights reserved. IF victaulic.com 7.0 REFERENCE MATERIALS 10.06: FireLock Installation-Ready Fittings 10.52: Style 922 Outlet Tee 10.85: VicFlex Series AH2 ad AH2-CC Braided Hose 11.02 Mechanical-T Bolted Branch Outlets 25.14: Victaulic IGS Groove Specification 1-101-103: FjreLpckTM lnstaIIationReadyTM Fittings Installation Instruction 1-102: FireLocklM InstaIlation_ReadyTM Fittings Installation Instruction -108: FireLockTM InstaIlationReadyTM Couoling -115: FireLock EZTM InstalIationReadyTM Reducing Coupling Installation Instruction l-ENDCAP: Victaulic End Car) Installation Safety Instructions l-V9: Style V9 Victaulic FireLocklM IGSTM InstallationReadyTM Sprinkler Coupling TM-RG2100: Operating and Maintenance Instructions Manual Victaulic No. 148 Length ½" DN15 outlet ~' DN2O outlet Equivalent Length of 1" E to E Sched. 40 Pipe (C=120) inches feet MITI meters 56 6.6 3.8 152 2.0 1,2 6-12 5.5 3.8 152-305 1.7 1.2 12-18 6.2 4.3 305-457 1.9 1.3 18-24 6.7 4.7 457-610 2.0 1.4 24-30 7.1 5.2 610-762 2.2 1.6 30-36 7.4 5.4 762-914 2.3 1.6 NOTE When installec in pipe to pipe connections or it is required by the authority having jurisdiction, the equivalent length data in the table above may apply. User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance witi industry standards and projec: specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right, The tems "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries, 10.54 10161 Rev 0 Updated 04/2020 0 2020 Victaulic Company. All rights reserved. Existing- For reference only ES-709DCDA Job Name Job Location Engineer Approval Series 709DCDA Double Check Detector Assemblies Sizes: 3" —1O"(80 - 250mm) Series 709DCDA Double Check Detector Assemblies are designed exclusively for use in accordance with water authori- ty containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e. glycerin wetting agents, stagnant water and water of non-potable qual- ity from being pumped or siphoned into the potable water line. Benefits: Detects leaks. . with emphasis on the cost of unac- countable water; incorporates a meter which allows the water utility to: detect leaks underground that historically create great annual cost due to waste. provide a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. All sizes are standardly equipped with resilient seated OSY shutoff valves, /8" x 3/4" (16 x 19mm) meter and ball type test cocks. Features Body construction fused epoxy coated cast iron Replaceable bronze seats Maximum flow at low pressure drop Compact for economy combined with performance Design simplicity for easy maintenance Furnished with 5/nfl x 3/4 ' (16 x 19mm) bronze meter No special tools required for servicing Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a potable water sup- ply. Degree of hazard present is determined by the local authority having jurisdiction. The unit shall be a complete assembly including UL listed resilient seated OSY shutoff valves and test cocks. The unit shall be ULJFM approved with ULIFM approved OSY shutoff valves. The auxiliary line shall consist of an approved backflow preventer and water meter. The assembly shall meet the basic requirements of ASSE 1048; AWWA Std. C51 0 for Double Check Valves. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be a Watts Regulator Company Series 709DCDA. Contractor Approval Contractor's P.O. No Representative 7O9DCDAOSY ut Cock Cover Seat Disc Check Assembly Module Features a modular design concept which facilitates complete maintenance and assembly by retaining the spring load. First and second check valve spring modules are not inter- changeable. Now Available WattsBox Insulated Enclosures. For more information, send for literature ES-WB. IMPORTANT INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify, product design, construction, specifications, or materials with- IWWATM out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequenty sold. Materials Body: Epoxy coated cast iron Seat: Bronze Disc Holder: Bronze Trim: Stainless steel Check Valve Discs: Rubber Test Cocks: Bronze Models Suffix: OSY - ULJFM outside stem and yoke resilient seated gate valves CFM - cubic feet per minute meter GPM - gallons per minute meter LF - 4" - 10" (100 - 250mm) without shutoff valves Dimensions - Weights Pressure - Temperature Temperature Range: 33°F - 110°F (05- 43°C) continuous, 140°F (60°C) intermittent Maximum Working Pressure: 175p5i (12.1 bar) Standards AWINA Standard C51 0 Approvals FM ~ ~uc jul )U <@> E) Approved Op us 1 B.64 048 Approved by the foundation for Cross-Connection Controland Hydraulic Research at the University of Southern California. Sizes 4" - 10" (100 - 250mm) approved for horizontal and vertical "flow up". Size 3" (76mm) approved for horizontal only. Factory Mutual approved 4" - 10" (100-250mm) vertical "flow up". ...................A .................................................. tiiisieir.ini UlT!W I In. mm in. A mm C in. mm D in. mm in. E mm I in. L mm in. A mm I in. mm U. in. mm W/OSYt gates lbs. kgs. 3 80 40 1016 18% 479 3½ 89 12 305 24 610 14 356 3 76 14 356 190 86 4 100 52 1321 22/4 578 33/4 95 17 432 34 864 15 381 6 152 14 356 403 183 6 150 621/2 1588 30½ 765 41/2 114 21 533 411/2 1054 16 406 7½ 191 16 406 727 330 8 200 75 1905 373/4 959 51/2 140 26 660 52 1321 17 432 1 9 229 21 533 1327 602 10 250 90 2286 453/4 1162 61/2 165 32 813 64 1626 18 457 1 101/4 260 25 635 2093 949 * Service clearance fo° check assembly from center. tUL/FM approved back-flow preventers must include ULJFM approved OSY. Capacity *Typical maximum system flow rate (7.5 ft/Sec.) **UL rated flow :••••• l•••••U ••• ....... _.___. _____. MMMMMMEIMMMMMEMMMMM• MMMMMMEIMMMMMEMMMMM• MMEIMMMMMEMMMMMN II 4. -•i•i ----riii' ------ ---- --- FILIJ =-- ---- if —___ ---- ---- ---- ---- ill ---- I II II II qI IlI .s1i II.1I1iThT =-- i_ II MI I Of 8" (200mm) kPa psi * ** CL 96 14 69 10 41 6 0. 14 2 00 0 400 800 1200 1660 2000 4000 gpm 0 1520 3040 456 6080 7600 15200 1pm 5 7.5 15 fps 1.5 2.3 4.6 mps Flow c'p ___---- UI I I d• 1UTt' U i•• NIII. I•• ii• I_ I. u_ Victaulic® FireLock NXTTM Preaction Trim \%tuIicr Series 769N 31.82 Patented 1.0 PRODUCT DESCRIPTION Available Sizes o 1112 - 87DN40 - DN200 Pressure Class Up to 300 psi/2068 kPa/20 Bar Minimum Air Pressure 13 psi/90 kPal.90 bar Acutation Options Series 776 Low Pressure Actuator Series 767 Electric/Pneumatic Actuator Series 798 Double-Pneumatic Actuator Electric Release 24V DC Normally closed solenoid Release Mechanism Non-Interlocked Single Interlocked Double Interlocked Valve Configurations Bare Pre-trimmed Vic-Quick Riser: Pre-trimmed and includes: Shut Off Valve (1 1/2 YDN40: Series 728 Ball Valve, 2' - 8'IDN50 - DN200: Series 705 FireLockTM Butterfly Valve) Pre-set alarm pressure switch Pre-set high or low air pressure switch (Dry Pilot Only) Drain Connection kit Fire-Pac Series 745 (refer to Victaulic publication 30.23) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com if victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) Application: o For use on fire protection systems only 2.0 CERTIFICATION/LISTINGS Uffm A © prEN 12259-9:2004 Cerl/LPCI ref. 1045106 1045/07 1045/06 3.0 SPECIFICATIONS - MATERIAL Body: Ductile iron conforming to ASTM A536, Grade 65-45-12. Clapper: Aluminum bronze Latch: Aluminum bronze Shafts: Stainless 17-4 Clapper Seal: Peroxide cured EPDM Bushings/Seat 0-rings: Nitrile Springs: Stainless steel Diaphragm: Peroxide cured EPDM with fabric reinforcement The 1W/DN4O and 2/0N50 valve sizes contain washers under the heads of the cover plate bolts. Item Description 1 Valve Body 2 Clapper 3 Clapper-Seal 4 Seal Ring 5 Seal Washer 6 Seal Retaining Ring 7 Seal Assembly Bolt 8 Clapper Spring 9 Clapper Shaft 10 Clapper Shaft Bushing and 0-Ring (Qty. 2) Item Description 11 Cover Plate 12 Cover Plate Gasket 13 Cover Plate Bolts 14 Latch 15 Latch Spring 16 Latch Spring Bushing and 0-Ring (Qty. 2) 17 Diaphragm 18 Diaphragm Cover 19 Diaphragm Cover Cap Screws (Qty. 8) 20 Latch Shaft 31.82 9999 Rev D updated 03/2021 02021 Victaulic Company. All rights reserved. IF victaulic.com 3.0 SPECIFICATIONS - MATERIAL (Continued) 0 Standard Trim Package: Non-Interlocked Pneumatic Release: The pneumatic release system uses a supervisory pilot line to detect a release event. When EITHER a pilot sprinkler or a system sprinkler operates, the water in the diaphragm chamber is released and the valve operates. Pneumatic/Electric Release: The Victaulic Electric Release System uses an electric solenoid valve, approved electric panel and a compatible detection system. The valve operates when the water in the diaphragm chamber is released when Either an electric detection or a system sprinkler operates. Single Interlocked Electric Release: The Victaulic Electric Release System uses an electric solenoid valve, approved electric panel and a compatible detection system. The valve operates when the water in the diaphragm chamber is released when a release system event occurs. Pneumatic Release: The pneumatic release system uses a supervisory pilot line to detect a release event. Only when a pilot sprinkler operates will the water in the diaphragm chamber be released and the valve operate. Double Interlocked Electric Release: The electric/pneumatic/electric release uses two electric detection devices, a fire detection device and a low pressure switch installed in the sprinkler system. The valve will actuate ONLY when BOTH a fire detection event and loss of system pressure occurs. Pneumatic/Electric Release: The pneumatic/electric preaction system uses both a pneumatically pressurized sprinkler system, and an electric release system, (composed of an approved solenoid valve, electric panel and an appropriate sensor). The valve will activate ONLY when there is a pressure loss in the sprinkler system AND the electric detection of a release event. Pneumatic/Pneumatic: The pneumatic/pneumatic system uses one Series 798 Double Pneumatic Actuator to control the Series 769N Actuated Valve. The valve will operate ONLY when there are sprinklers activated in both the pilot line and the sprinkler system. All required pipe nipples and fittings - standard galvanized finish All standard trim accessories All required gauges Series 755 Manual Release Panel O Optional Trim Package: Black Trim for Foam Systems - If the valve is intended for use in a foam system, black trim must be ordered, per NFPA requirements. Specify this requirement on the order. 31.82 9999 Rev 0 Updated 03/2021 © 2021 Victaulic company. All rights reserved. if victaulic.com 3.0 SPECIFICATIONS - MATERIAL (Continued) Optional Accessories: O Alarm Pressure Switch - Alarm pressure switches activate electrical alarms at the control panel when the 769N valve actuates and flows water into the system piping. (Note: an open sprinkler may not actuate a 769N valve but any low air alarms should operate.) O Air Supervisory Pressure Switch - Air Pressure Supervisory Switches are used to monitor low and high system air pressure and are factory pre-set. O Series 746-LPA Dry Accelerator - The Series 746-LPA Dry Accelerator is required when the Series 769N Preaction trim is installed in large systems to improve response time. Refer to Victaulic publication 30.64. O Series 760 Water Motor Alarm - The Series 760 Water Motor Alarm is a mechanical device that sounds when the 769N valve actuates and is filling the system and discharging any water through any open sprinklers. Refer to Victaulic publication 30.32. O Series 75B Supplemental Alarm Device - The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Refer to Victaulic publication 30.33. O Series 75D Water Column Kit - The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Refer to Victaulic publication 30.34. O AutoConvert Kit - The AutoConvert Kit includes the Series 776 Low Pressure Actuator, latching solenoid, strainer, 3-in-1 strainer/check/restrictor assembly, air pressure gauge and assembly trim. It is ordered separately and can be installed on any FireLock NXTTM Single Interlock or Double Interlock Preaction system that includes a solenoid. O Air Supply System - The air supply system contains all components for establishing and maintaining air in the system. The compressor ball valves, and required trim are included in the air supply system. O Air Compressor Refer to Victaulic publication 30.22. O Air Maintenance Trim Assembly Refer to Victaulic publication 30.35. O Fire Alarm Control Panels O Drain Connection Kit - 0 Redundant Electric Solenoid made by alternate manufacturer required by LPCB approval. 31.82 9999 Rev U Updated 03/2021 © 2021 Victaulic Company. All rights reserved. if vkfuilirrnm p 4.0 DIMENSIONS A 4'7DN 100 valve with single-interlocked pneumatic release preaction trim is shown below 11/2 - 27DN40 - DN50 configurations contain A719 mm drain valves 21/2 - 3'7DN65 - DN80 and 73.0 mm configurations contain 11/4731 mm drain valves 4- 8"/DN100 - DN200 configurations contain 2"/50 mm drain valves Full Open Size Dimensions Weight Each Actual Outside Without With Nominal Diameter Al Al2 B3 C D4 D14 E F G H K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 11/2 1.900 9.00 16.37 34.25 9.25 16.25 11.00 9.00 3.25 10.25 24.00 6.00 16.7 43.0 DN40 48.3 229 416 870 235 413 279 229 83 260 610 152 7.6 19.5 2 2.375 9.00 13.83 34.25 9.25 17.50 11.00 9.00 3.25 10.25 24.00 6.00 17.0 43.0 DN50 60.3 229 351 870 235 445 279 229 83 260 610 152 7.7 19.5 21/2 2.875 12.61 16.51 35.75 11.25 20.00 12.50 9.50 4.00 9.75 26.00 6.50 41.0 65.0 73.0 320 419 908 286 508 318 241 102 248 660 165 18.7 1 29.5 3.000 12.61 16.51 35.75 11.25 20.00 12.50 9.50 4.00 9.75 26.00 6.50 41.0 1 65.0 DN65 76.1 320 419 908 286 508 318 241 102 248 660 165 18.7 29.5 3 3.500 12.61 16.51 35.75 11.25 20.00 12.50 9.50 4.00 9.75 26.00 6.50 41.0 65.0 DN80 88.9 320 419 908 286 508 318 241 102 248 660 165 18.7 29.5 4 4.500 15.03 19.85 36.50 13.50 22.25 13.50 11.00 4.75 8.50 28.00 8.00 59.0 95.0 DN100 114.3 382 504 927 343 565 343 279 121 216 711 203 26.7 43.0 6.500 16.00 22.13 36.75 14.00 24.50 13.25 11.00 4.50 8.25 28.50 8.25 80.0 116.0 165.1 406 562 933 356 622 337 279 114 210 724 210 36.2 1 52.6 6 6.625 16.00 22.13 36.75 14.00 24.50 13.25 11.00 4.50 8.25 28.50 8.25 80.0 116.0 DN150 168.3 406 1 562 1 933 356 1 622 337 1 279 1 114 1 210 724 210 36.2 52.6 8 8.625 17.50 1 23.02 1 39.50 14.75 1 27.00 13.50 1 12.25 1 4.75 1 8.25 31.25 9.25 122.0 158.0 DN200 219.1 445 585 1003 375 686 343 311 121 210 1 794 235 55.3 71.6 1 The 'A" dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water supply main control valve. For systems with the optional Series 746-LPA Dry Accelerator, add 11.50 inches/292 mm to the "B" dimension to account for the additional height. The "D" and "Dl" dimensions are not fixed measurements. The drip cup can be rotated to provide more clearance at the back of the trim. NOTES The drawings shown above reflect the single-interlocked pneumatic release trim with Series 776 Low-Pressure Actuator. In addition, these dimensions can be applied to all other trim configurations featured within this manual. components shown as dotted lines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. 31.82 9999 Rev D Updated 03/2021 © 2021 Victaulic company. All rights reserved. if victaulic.com 4.1 DIMENSIONS A 4YDN100 valve with electric autoconvert dry release preaction trim is shown below 11/2 - 2YDN40 - DN50 configurations contair 3/4719 mm drain valves 2 112 - 37DN65 - DN80 and 73.0 mm configurations contain 11/4731 mm drain valves 4 - 8"/DN100 - DN200 configurations contain 2"/50 mm drain valves Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A' Al2 B3 C D Dl E F G H K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 1 ½ 1.900 9.00 16.37 38.00 15.50 25.00 16.25 9.50 3.25 10.25 27.75 6.00 16.7 43.0 DN40 48.3 229 416 965 394 635 413 241 83 260 705 152 7.6 19.5 2 2.375 9.00 13.83 38.00 15.50 25.00 16.25 9.50 3.25 10.25 27.75 6.00 17.0 43.0 DN50 60.3 229 351 965 394 635 413 241 83 260 705 152 7.7 19.5 21/2 2.875 12.61 16.51 40.75 16.00 24.00 15.00 9.50 4.00 9.75 31.00 6.50 41.0 65.0 73.0 320 419 1035 406 610 381 241 102 248 787 165 18.7 29.5 3.000 12.61 16.51 40.75 16.00 24.00 15,00 9.50 4.00 9.75 31.00 6.50 41.0 65.0 DN65 76.1 320 419 1035 406 610 381 241 102 248 787 165 18.7 1 29.5 3 3.500 12.61 16.51 40.75 16.00 24.00 15.00 9.50 4.00 9.75 31.00 6.50 41.0 65.0 DN80 88.9 320 419 1035 406 610 381 241 102 248 787 165 18.7 29.5 4 4.500 15.03 19.85 42.50 15.25 22.50 14.75 11.00 4.75 8.50 34.00 7.50 59.0 95.0 DN100 114.3 382 504 1080 387 572 375 279 121 216 864 191 26.7 43.0 6.500 16.00 22.13 42.50 15.25 26.00 15.25 11.00 4.50 8.25 34.25 8.25 80.0 116.0 165.1 406 562 1080 387 660 387 279 1 114 210 870 210 36.2 1 52.6 6 6.625 16.00 22.13 42.50 15.25 26.00 15.25 11.00 4.50 8.25 34.25 8.25 80.0 116.0 DN150 168.3 406 562 1080 387 1 660 387 279 114 210 870 210 36.2 52.6 8 8.625 17.50 23.02 44.50 18.50 30.00 16.00 12.25 4.75 8.25 36.25 9.25 122.0 158.0 DN200 219.1 445 1 585 1130 470 762 406 311 121 210 921 235 55.3 71.6 1 The A" dimension is the actual takeout dimension of the valve body. The Al" dimension is the actual takeout dimension of the valve body with water Supply main control valve. For systems with the optional Series 746-LF'A Dry Accelerator, add 9.50 inches/241 mm to the B" dimension to account for the additional height. NOTES The drawings shown above reflect the electric Autoconvert dry release trim. In addition, these dimensions can be applied to the redundant solenoid valve configuration. Components shown as dotted lines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. 31.82 9999 Rev D Updated 03/2021 © 2021 Victaulic Company. All rights reserved. IF victaulic.com 4.2 DIMENSIONS A 4'YDN100 valve with double-interlocked electric/pneumatic autoconvert dry release preaction trim is shown below 11/2 - 27DN40 - DN50 configurations contain A719 mm drain valves 21/2 - 3"/DN65 - DN80 and 73.0mm configurations contain 11/4731 mm drain valves 4- 87DN100 - DN200 configurations contain 2750 mm drain valves Size Dimensions Weight Each Actual Outside Without With Nominal Diameter Al Al2 B3 C D Dl E F G H K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 11/2 1.900 9.00 16.37 36.50 17.50 20.25 13.50 9.00 3.25 10.25 26.25 6.00 16.7 43.0 DN40 48.3 229 416 927 445 514 343 229 83 260 667 152 7.6 19.5 2 2.375 9.00 13.83 36.50 17.50 20.25 13.50 9.00 3.25 10.25 26.25 6.00 17.0 43.0 DN50 60.3 229 351 927 445 514 343 229 83 260 667 152 7.7 19.5 21/2 2.875 12.61 16.51 38.25 17.50 20.75 13.50 9.50 4.00 9.75 28.50 6.50 41.0 65.0 73.0 320 419 972 445 527 343 241 102 248 724 165 18.7 29.5 3.000 12.61 16.51 38.25 17.50 20.75 13.50 9.50 4.00 9.75 28.50 6.50 41.0 65.0 0N65 76.1 320 419 972 445 527 343 241 102 248 724 165 18.7 29.5 3 3.500 12.61 16.51 38.25 17.50 20.75 13.50 9.50 4.00 9.75 28.50 6.50 41.0 65.0 DN80 88.9 320 419 972 445 527 343 241 102 248 724 165 18.7 29.5 4 4.500 15.03 19.85 39.00 14.25 20.25 12.50 11.00 4.75 8.50 30.50 7.50 59.0 95.0 DN100 114.3 382 504 991 362 514 318 279 121 1 216 775 191 26.7 43.0 6.500 16.00 22.13 40.25 15.00 20.75 13.00 11.00 4.50 8.50 31.75 8.25 80.0 116.0 165.1 406 1 562 1022 381 527 330 279 114 216 806 210 36.2 52.6 6 6.625 16.00 22.13 40.25 15.00 20.75 13.00 11.00 4.50 8.50 31.75 8.25 80.0 116.0 DN150 168.3 406 562 1022 381 527 330 279 114 216 806 210 36.2 52.6 8 8.625 17.50 23.02 41.75 16.00 21.50 13.50 12.25 4.75 8.25 33.50 9.25 122.0 158.0 DN200 219.1 445 585 1060 406 546 343 311 121 1 210 1 851 235 55.3 71.6 1 The "A" dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water Supply main control valve. For systems with the optional Series 746-LPA Dry Accelerator, add 9.50 inches/241 mm to the "B" dimension to account for the additional height NOTES The drawings shown above reflect the electric Autoconvert dry release trim. In addition, these dimensions can be applied to the redundant solenoid valve configuration. components shown as dotted lines denote optional equipment. The recommended drain connection kit (shaded in,orange) is for reference and takeout dimensions. This drain connection comes standard when the VOR assembly is ordered. 31.82 9999 Rev o updated 03/2021 © 2021 Victaulic company. All rights reserved. a, victaulic.com 4.3 DIMENSIONS A 47DN100 valve with double-interlocked pneumatic/pneumatic release preaction trim is shown below 1112 - 2'7DN40 - DN50 configurations contain 1/4'719 mm drain valves 2 ½ - 3'7DN65 - DN80 and 73.0 mm configurations contain 11/4731 mm drain valves 4- 87DN100 - DN200 configurations contain 2750mm drain valves Full Open Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A' Al2 B3 C D D14 D24 E F G H K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm mm kg kg 1½ 1.900 9.00 16.37 36.00 9.25 21.25 11.00 23.50 9.25 3.25 10.25 25.75 6.00 16.7 43.0 DN40 48.3 229 416 914 235 540 279 597 235 83 260 654 152 7.6 19.5 2 2.375 9.00 13.83 36.00 9.25 21.25 11.00 23.50 9.25 3.25 10.25 25.75 6.00 17.0 43.0 DN50 60.3 229 351 914 235 540 279 597 235 83 260 654 152 7.7 19.5 21/2 2.875 12.61 16.51 37.75 11.25 22,50 12.50 24.75 9.50 4.00 9.75 28.00 6.50 41.0 65.0 73.0 320 419 959 286 572 318 629 241 102 248 711 165 18.7 29.5 3.000 12.61 16.51 37.75 11.25 22.50 12.50 24.75 9.50 4.00 9.75 28.00 6.50 41.0 65.0 DN65 76.1 320 419 959 1 286 572 1 318 629 1 241 102 248 711 1 165 18.7 29.5 3 3.500 12.61 16.51 37.75 11.25 22.50 12.50 24.75 9.50 4.00 9.75 28.00 6.50 41.0 65.0 DN80 88.9 320 419 959 286 572 318 629 241 102 248 711 165 18.7 29.5 4 4.500 15.03 19.85 38.50 13.50 23.75 13.50 26.25 10.00 4.75 8.50 30.00 8.00 59.0 111.0 DN 100 114.3 382 504 978 343 603 343 667 254 121 216 762 203 26.7 50.3 6.500 16.00 22.13 39.25 14.00 24.50 13.25 27.75 11.00 4.50 8.25 31.00 8.25 80.0 132.0 165.1 406 562 997 1 356 622 1 337 705 1 279 114 210 787 1 210 36.2 59.8 6 6.625 16.00 22.13 39.25 14.00 24.50 13.25 27.75 11.00 4.50 8.25 31.00 8.25 80.0 132.0 DN1SO 168.3 406 562 997 356 622 337 705 279 114 210 787 210 36.2 59.8 8 8.625 17.50 41.25 14.75 27.00 13.50 29.75 12.25 4.75 8.25 33.00 9.25 122.0 174.0 DN200 219.1 445 :23.02 1048 375 686 343 756 311 1 121 210 838 235 55.3 78.9 1 The A" dimension is the actual takeout dimension of the valve body. 2 The Al" dimension is the actual takeout dimension of the valve body with water Supply main control valve. For systems with optional Series 746-LPA Dry Accelerators, add 11.50 inches/292 mm to the B" dimension to account for the additional height. The "D" and Dl" dimensions are not fixed measurements. The drip cup can be rotated to provide more clearance at the back of the trim. NOTES components shown as dotted lines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. 31.82 9999 Rev D Updated 03/2021 © 2021 victaulic company. All rights reserved. a, ,irhiiiIir 5.0 PERFORMANCE Hydraulic Friction Loss The chart below expresses the flow of water at 65017/180C through an open valve. MEN SE SlIIIIIIV21I1IIVWilIIIlH ____. aa • - uinniuunoauuuun ON • I 11111110 --- -- .0 ,, ' I ••iu •• ____ __. iuu ii ii mmuuuii U Ill lull iiiiiii 1111111 111111 11111111 11111111 11111111 11111111 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 800 3,000 8,000 FLOW RATE - GPM 6.0 5.0 4.0 3.0 - 2.0 'I, a. a. o 1.0 0.9 0.8 0.7 0.6 05 /) 0.4 Ui 0.3 0.2 0.1 10 Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 769N FireLock NXTTM. Preaction Trim in equivalent feet of straight pipe. Size Equivalent Actual Nominal Outside Diameter Length of Pipe inches inches feet DN mm meters 11/2 1.900 3.00 DN40 48.3 0.914 2 2.375 9.00 DN50 60.3 2.743 21/2 2.875 8.00 73.0 2.438 3.000 8.00 DN65 76.1 2.439 3 3.500 17.00 DN80 88.9 5.182 4 4.500 21.00 DN100 114.3 6.401 6.500 22.00 165.1 6.706 6 6.625 22.00 DN150 168.3 6.706 8 8.625 50.00 DN200 219.1 15.240 Cv Values: Cv values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. Formulas for Cv values Where: AP = 02/Cv2 Flow Coefficient Q = Cv x JAP C 0 (Flow) GPM Size Full Open Actual Outside Nominal Diameter Flow Coefficient inches inches Cv DN mm K 1½ 1.900 60 DN40 48.3 52.0 2 2.375 110 DN50 60.3 95.0 21/2 2.875 180 73.0 156.0 3.000 180 DN65 76.1 156.0 3 3.500 200 DN80 88.9 173.0 4 4.500 350 DN100 114.3 302.8 6.500 1000 165.1 865.0 6 6.625 1000 DN150 168.3 865.0 8 8.625 1500 DN200 219.1 1297.5 AP (Pressure Drop) psi 31.82 9999 Rev D Updated 03/2021 © 2021 victaulic Company. All rights reserved. if victaulic.com S 5.0 PERFORMANCE (Continued) Air Supply Requirements Minimum: 13 psil90 kPa/.9 bar regardless of the system water pressure Maximum Recommended: 18 psi/124 kPa/1.24 bar Sizing the compressor: Engineer/system designer is responsible Entire system must be charged to the required air pressure within 30 minutes to meet NFPA requirements An oversized compressor will slow down or possibly prevent valve operation Compressor filling the system too fast: May be necessary to restrict the air supply Ensure that air exhausted from an open sprinkler or manual release valve is not replaced by the air supply system as fast as it is exhausted Compressor Requirements Base or Riser Mounted Compressors: "On" or "low" pressure setting: 13 psi/90 kPa/.9 bar "Off" or "high" pressure setting: 18 psi/124 kPa/1.24 bar Victaulic Series 7C7 riser mounted and pre-set for pressure requirements (refer to Victaulicpublication 30.22). If the compressor is not equipped with a pressure switch, the Series 757P Air Maintenance Trim Assembly with pressure switch should be installed (refer to Victaulic publication 30.36). Shop Air or Tank-Mounted Air Compressors: Series 757 Regulated Air Maintenance Trim Assembly should be installed (refer to Victaulic publication 30.35) 13 psi/90 kPa/.9 bar should be used as the set point for the air regulator The compressor cut-in (turn-on) pressure setting should be at least 5 psi/34kPa/34 bar above the set point of the air regulator. Exploded View Trim Series 757 Regulated Air Maintenance Trim Assembly (refer to Victaulic publication 30.35) Compressor Requirements and settings for systems installed with Series 746 or Series 746-LPA dry accelerators A tank-mounted air compressor with a Series 757 Regulated AMTA must be used to supply air to system installed with a Series 746 or Series 746-LPA Dry Accelerator. In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection, since air can be supplied continuously to the sprinkler system for an extended time period. Electrical Release Requirements Verify that an approved control panel is installed for proper system operation. 31.82 9999 Rev D Updated 03/2021 © 2021 Victaulic Company. All rights reserved. a' victaulic.com 5.0 PERFORMANCE (Continued) Autoconvert Requirements System must be installed in conjunction with a Notifier RP-2001 family panel, System Sensor PDRP-2001, or a Potter 4410RC panel to be in compliance with FM Approvals. AutoConvert Trim: In the event of an AC power loss, the AutoConvert module latches from Closed to Open with a quick electrical pulse. To stay open, no further current draw is required as would be needed in a normally open solenoid. This opened pathway allows the included Series 776 Low Pressure Actuator to operate as a dry actuator, putting the preaction system into a Non-Interlocked condition. In this case, an electrical release from the FACP and an air loss in the system or the system air loss would allow the Series 769N valve to actuate, filling the pipe with water. Upon an AC power return, the Auto-Convert module senses the restoration and latches the path from the Series 776 Low Pressure Actuator closed, returning the preaction valve to its standard release method. 6.0 NOTIFICATIONS WARNING N-10 41'a OW"*" au rI Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 31.82 9999 Rev D updated 03/2021 © 2021 Victaulic company. All rights reserved. I, victaulic.com 7.0 REFERENCE MATERIALS 30.22: FireLockTM Compressor Package Series 7C7 30.23: FireLockrM Fire-Pac Series 745 30.32: FireLockTM Water Motor Alarm Series 760 30.33: Supijlemental Alarm Kit Series 75B 30.34: Automatic Water Column Drain Kit for FireLock NXTTM Valves Series 75D 30.35: FireLockTM Air Maintenance Trim Assembly Series 757 30.36: FireLockTM Air Maintenance Trim Assembly Series 757P 30.41: FireLocklM Manual Pull Station Series 755 30.61: FireLockTM Double-Pneumatic Actuator Series 798 30.62: FireLockTM Low Pressure Actuator Series 767 30.63: FireLockTM Electric Solenoid Series 753E 30.64: FireLockTM Dry Accelerator Series 746-LPA 30.65: FireLockTM Low Pressure Actuator Series 776 30.84 FireLock NXTTM AutoConvert Trim Assembly for Preaction Devices l-769N.Preaction 1-769N.Preaction/DPA 1-769N. Preaction/EPA 1-769N .Preaction/AC-Elec 1-769N .Pregctipn/AC-EP Scan for reference documents. User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested one of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details, Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic company, and/or its affiliated entities, in the U.S. and/or other countries. 31.82 9999 Rev D Updated 03/2021 0 2021 Victaulic Company. All rights reserved. Maintenance/ Compressor Assembly SERIES 7C7 For FireLock NXTTM Series 768 Dry Valves, Series 769 Deluge and Preaction Valves, Series 764 Alternate Valves. Note: The Series 707 Air Maintenance/Compressor Assembly is designed for systems that do not require an accelerator to achieve the required system pressure performance. If an accelerator is required, a tank-mounted compressor with a regulated air maintenance device should be used. SERIES 7C7 PRODUCT DESCRIPTION The Series 7C7 Air Maintenance/Compressor assembly consists of a riser-mounted compressor, Series 757P Air Maintenance Device and flexible hoses for installation. It is designed to ensure the valve system can achieve operational air pressure within 30 minutes of discharge, in accordance with NFPA 13 requirements (7.2.6.2.2). The Series 757P Air Maintenance Device is UL Listed and FM Approved. The Series 707 Assembly is available with /ó, ½ and ½ horsepower compressors depending upon the system requirements. COMPRESSOR CAPACITIES The engineer/system designer is responsible for sizing the compressor so that the entire system is charged to the required air pressure within NFPA guidelines (30 minutes). DO NOT oversize the compressor to provide more airflow. An oversized compressor will slow down or possibly prevent valve operation. Nominal AC Voltage/1-1z Pressure Hp 10%) psi/Bar 1/6 110/60ô0 18 30 175 275 12.1 Amps 1.2 0.7 1.1 1/3 110/60 18 30 375 525 1.2 30 1.4 - 2.0 1/3 220/50 18 160 235 ________ - 1.2 0.6 0.9 1/3 220/50 18 oo 450 - -- -- -- 660 4.4 Amps 1.2 1.7 2.5 1/3 220/60 18 30 370 400 1.2 1.4 1.5 1/2 110/50 18 1.2 - 30 30 660 2.5 780 670 2.5 830 66 Amps 1/2 110/60 18 1.2 3.0 3.1 3/4 220/50 18 30 600 675 1.2 2.3mm _ 2.5 3/4 -.------ ------------ 220/60 18 __- 30 700 775 i 1.2 2.7 2.9 3/4 220/50 18 60 1200 -----'-.-. 1350 3.8 Amps 1.2 4.5 5.0 3/4 220/60 18 60 1375 1525 1.2 5.2 5.8 NOTE: Refer to the charts on the following pages for minimum required fill capacities to 13 psi/0.9 Bar. Low air alarms will clear at 13 psi/0.9 Bar. In addition, these charts contain higher capacities to 18 psi/1.2 Bar that are not shown in the table above. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location - Date Approved Date WtAIW ,ir+,uuIir mm I FIRE PROTECTION PRODUCTS - DEVICES 30.22 Air Maintenance/ Compressor Assembly SERIES 7C7 ASSEMBLY DIMENSIONS Series 7C7 - 1I2HP Compressor Series 7C7 - 1/3HP Compressor Series 7C7 - 1I6HP Compressor -Series 7C7 ____ 1 14.5 4.8 6.55 15.54 1'76.1 214.77 4.8 6.55 15.54 2 ½" &15.03 4.8 6.55 15.54 3 15.36 4.8 6.55 15.54 4" 15.94 4.8 6.55 15.54-- 6'& 165.5 16.98 4.8 6.55 15.54 8" 18.01 4.8 6.55 15.54 7C7 113HP. mpressor __ 11/2' 14.53 5.00 6.55 15.38 14.78 SOb 6.55 15.38 21/2'& 76.1 15.04 5.00 6.55 15.38 15.36 5.00 6.55 15.38 15.88 5.00 6.55 15.38 6'& 165.5 16.98 5.00 6.55 15.38 8" 18.02 5.00 6.55 15.38 lSeries 70. . 11/2" 14.53 4.60 6.55 15.38 14.78 4.60 6.55 15.38 2½" & 76.1 15.04 4.60 6.55 15.38 15.36 4.60 6.55 15.38 15.88 4.60 6.55 15.38 6'& 165,5 16.98 4.60 6.55 15.38 8" 18.02 4.60 6.55 15.38 wwu, s,irt,iilir mm / 18 psi 13 psi FIRE PROTECTION PRODUCTS - DEVICES 30.22 Air Maintenance/ Compressor Assembly SERIES 7C7 ASSEMBLY PERFORMANCE (1/2 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. Estimated Time to Reach Various Pressures - Estimated Time to Reach Various Pressures - Series 7C7 with 1/2-hp (1 10 VAC, 50Hz) Compressor and Auto Vent Series 70 with 1/2-hp (1 10 VAC, 50 Hz) Compressor and No Auto Vent 5° 45 18 psi 40 35 13 psi 30 25 C C 20 F 15 10 0 50 100 150 200 250 300 353 400 450 500 550 600 650 700 750 800 850 900 9001000 System Size (gallons) Estimated Time to Reach Various Pressures - Series 7C7 with 1/2-hp (110 VAC, 60-Hz) Compressor and Auto Vent 18 psi System Size (gallons) Estimated Time to Reach Various Pressures - Series 7C7 with 1/2-hp (110 VAC, 60 Hz) Compressor and No AutoVent to psi 13 psi IN System Size (gallons) System Size (gallons) tnww uirtiuiIir mm Estimated Time to Reach Various Pressures -220-volt Option Series 7C7 with 1/3-hp (220-240 VAC, 50 Hz) Compressor and No AutoVenl FIRE PROTECTION PRODUCTS - DEVICES 30.22 Air Maintenance/ Compressor Assembly SERIES 7C7 ASSEMBLY PERFORMANCE (1/3 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. Estimated Time to Reach Various Pressures - Estimated Time to Reach Various Pressures - Series 7C7 with 1/3-hp (11OVAC) Compressor and Auto Vent Series 7C7 with 1/3-hp (1 10 VACI Compressor and No Auto Vent 50 40 30 B 20 10 18 psi 13 psi 20 B B Ia 10 Is psi 13 psi 7----;7 / 7- 7 - -------- v-- / ,- / 7, - -7-7-- 7- /7 50 100 150 200 250 300 350 400 450 500 550 600 650 700 System Size (gallons) 50 100 150 200 250 300 350 400 450 500 550 500 650 700 750 System Size (Gallons) Estimated Time to Reach Various Pressures - 220-volt Option Series 7C7 with 1/3-hp (220-240 VAC, 50-Hz) Compressor and Auto Vent 1.2 Bar 0.9 Bar 2 0.6 1.0 1.4 18 2.2 2.6 3.0 System Size (cubic meters) Estimated Time to Reach Various Pressures - 220-volt Option Series 70 with 1/3-hp (220-240VAC, 60-Hz) Compressor and Auto Vent 0 05 10 1.3 2.0 2.3 3.0 System SizeNo)ume (cubic meters) Estimated Time to Reach Various Pressures - 220-volt Option Series 7C7 with 1/3-hp (220-240 VAC 60 Hz) Compressor and No Auto Vent 60 . 1.2 Bar 1 2 7Bar so 0.9 Bar o . 0.9 Bas 30 u B _ p 20 ii 0 555' ~ ~ 0 0.5 1.5 1.5 Jo 2.5 3.0 0.2 0.4 0.6 0.0 1.0 1.2 1.4 1.6 1.8 20 2.2 2.4 2.6 2.0 System SizeNolame (cubic meters) System Size (cubic meters) NOTE: Refer to the following page for charts reflecting the 220-volt 1/3-hp option. www uirtt.iilir mm / FIRE PROTECTION PRODUCTS - DEVICES 30.22 Air Maintenance/ Compressor Assembly SERIES 7C7 ASSEMBLY PERFORMANCE (1/6 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. Estimated Time to Reach Various Pressures - Estimated Time to Reach Various Pressures - Series 7C7 with 1/6-hp (110 VAC) Compressor and Auto Vent Series 7C7 with 1/6-hp (I 10 VAC) Compressor and No AutoVent 70 30 18 psi 60 13 psi 50 20 40 8 E 10 30 20 01 to so 100 150 200 250 300 350 4 System Size (gallons) 50 lOt 150 200 250 300 350 400 System Size (Gallons) www uirts.iilir mm / Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flex Hose (½-inch NPT Male x Female) 5 2 Split Hanger for ½-inch Pipe 6 2 Hose Clamp 7 1 Close Nipple (¼-inch NPT) 8 3 Close Nipple (½-inch NPT) 9 3 90 Female Elbow (½-inch NPT) 10 2 Hex-Head Bolt (1/.- 16 x ¼-inch Long) 11 4 LockWasher(14sinch) 12 2 Lock Washer )½inch) 13 4 Hex Nut (¼-2OUNC) 14 2 Straight Conduit Connector (½-inch) 15 1 Liquid-Tight Conduit (½ inch a 91/2 inches Long) 16 1 14 AWG, 3-Strand Cable (25 inches Long) 17 3 68 U-Style Wire Connector 18 1 Identification Tag 19 1 Compressor Air Intake Filter 20 1 Nipple (½-inch NPTn 10 inches Long) 21 1 Nipple (½-inch NPTx 41/2 inches Long) 22 1 Union (½-inch NPT) 23 1 Reducing Bell (½-inch NPTx ½-inch NPT) 24 1 14 AWG Grounded Cord with Plug (51/2 feet Long) 25 1 Strain Relief Connector' 26 1 Identification Labe( NOTE: Items 24- 26 apply only to the CIA version FIRE PROTECTION PRODUCTS - DEVICES 30.22 Air Maintenance/ Compressor Assembly SERIES 7C7 EXPLODED VIEW DRAWING — SERIES 7C7 AIR MAINTENANCE COMPRESSOR ASSEMBLY WITH 1/2-HP COMPRESSOR wsaltal s,irtr.uilir mm Exaggerated for Clarity FIRE PROTECTION PRODUCTS - DEVICES 30.22 Air Maintenance/ Compressor Assembly SERIES 7C7 EXPLODED VIEW DRAWING - SERIES 7C7 AIR MAINTENANCE COMPRESSOR ASSEMBLY WITH 1/3-HP COMPRESSOR Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flea Hose (½-inch NPT Male a Female) 5 2 Split Hanger for ½-inch Pipe 6 2 Hose Clamp 7 1 Close Nipple (¼-inch NPT( 8 2 Close Nipple (½-inch NPT) 9 3 900 Female Elbow (½-inch NPT( 10 4 Hen-Head Bolt )f4s - lB x U-inch Long( 11 2 Hen-Head Bolt (94-16 n %-inch Long) 12 4 Lock Washer (f4r inch) 13 2 Lock Washer (3A inch) 14 4 Hex Nut (5Aa-1B) 15 2 Straight Conduit Connector (½ inch) 16 1 Liquid-Tight Conduit )½ inch n 91/2 inches Long) 17 2 14 AWG, 3-Strand Cable (25 inches Long) 18 3 #B U-Style Wire Connector 19 1 Identification Tag 20 t Reducing Bell (½-inch NPT x ¼-inch NPT( 21 1 Nipple (½-inch NPT n 1½ inches Long) 22 1 Nipple (½-inch NPT n5½ inches Long) 23 1 Nipple (½-Inch NPT n 91/2 inches Long) 24 1 Union (½-inch NPT( 25 1 14 AWG Grounded Cord with Plug (51h feet Long) 26 1 Strain Relief Connector 27 1 Identification Label 4010: Items 25- 27 apply only to the CIA version EXPLODED VIEW DRAWING - SERIES 7C7 AIR MAINTENANCE COMPRESSOR ASSEMBLY WITH 1/6-HP COMPRESSOR Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flex Hose (½-inch NPT Mule x Female) 5 2 Split Hunger for ½-inch Pipe 6 2 Hose Clamp 7 3 90 Female Elbow (½-inch NPT( 8 1 Close Nipple (¼-inch NPT( 9 2 Close Nipple (½-inch NPT( 10 2 Hex-Head Bolt (3/a - 16x~-inch Long) 11 3 Hen-Head Bolt (#10-32 x ½-inch Long) 12 2 Lock Washer (% inch) 13 3 Lock Washer (#10( 14 1 Identification Tag 15 1 Straight Connector, Flexible Cord 16 1 Connector, Flexible Cord 17 1 Liquid-Tight Conduit (½ inch x 11½ inches Long) 18 3 #8 U-Style Wire Connector 19 1 Reducing Bell (½-inch NPTx ¼-inch NPT) 20 1 Nipple (½-inch NPTx 11/2 inches Long) 21 1 Nipple (½-inch NPTx 9 inches Long) 22 1 Union )½-inch NPT( 23 1 Nipple (½-inch NPTx 5 inches Long) 24 1 Identification Label 25 1 Strain Relief Connector 26 1 14 AWG Grounded Cord with Plug (5½ feet Long)* Exaggerated for Clarity NOTE Items 24-26 apply only to the CSA version wtnw urt,silir eArn / INCOMING POWER SUPPLY (REFERENCE COMPRESSOR DATA PLATE) Li L2 o o - - - 9 9 1 l- i ri I L L- -J Air Maintenance/ Compressor Assembly SERIES 7C7 ELECTRICAL INFORMATION A DANGER Only qualified electricians should connect .•-,. o incoming power to the Series 7C7 Air \Maintenance/Compressor Assembly. To reduce the risk of electric shock, check the electrical source for proper grounding. Failure to follow these instructions could result in death or serious personal injury. -. - Conhec ELECTRICAL CONNECTION NOTE: NEMA 1 Enclosure - intended only for indoor use Only qualified electricians should make the connection to the incoming power supply. All wiring shall be completed in accordance with requirements of the local authority having jurisdiction and any applicable electrical codes. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. WARNING 4.WARNING This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300. For complete contact information, visit www.victaulic.com / FireLock® Butterfly Valve Ataulicr (series 705)with Weatherproof Actuator 10.81 1.0 PRODUCT DESCRIPTION Available Sizes: 2 - 12/50 - 300 mm cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. Designed for fire protection services only. Features a weatherproof actuator housing Approved for indoor and outdoor use. Actuation options: Hand wheel (2 - 12/50 - 300 mm) Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS c®us nVdS [LPC LISTED G410001 104j/04 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com victaulic.com 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM ] Vds LPCB 50 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 21/2 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300ps1/2068kPa 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300ps1/2068kPa up to 300psi/2068kPa io up to 300psi/2068kPa up to 300psi/2068kPa up to 300ps1/2068kPa up to 300psi/2068kPa 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa io up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS - MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 - 6"/50 - 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 - 12"I200 - 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade "E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: 036000 brass Bearings: Stainless steel with TEE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 0 2 - 8/50 - 200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing O 10— 12/250-300 mm: Steel worm and cast iron quadrant gear, in a cast irbn housing 10.81 5662 Rev I updated 07/2020 0 2020 Victaulic Company. All rizhts reserved. victaulic.com 4.0 DIMENSIONS Series 705 Size Dimensions Actual Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 - - 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 - - 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 76.1 mm 3.000 3.77 2.28 7.54 - - 4,00 4.22 4.50 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 - - 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 108mm 4.250 4.63 2.88 8.81 - - 5.50 4.22 4.50 2.20 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 - - 139.7 107.2 114.3 55.9 133mm 5.250 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 133.0 149.4 85.1 276.4 166.6 1 157.2 160.0 65.5 1397 mm 5.500 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 159mm 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 1 289.1 10.4 191.0 157.2 160.0 65.5 1651 mm 6.500 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 - 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10,750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 - 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 - 323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 NOTE Optional W115 mm tap available. Contact Victaulic for details. 10.81 5662 Rev I Updated 07/2020 0 2020 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Series 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/rn inches inches of pipe 2 2.375 6 50 60.3 1.8 2½ 2.875 6 65 73.0 1.8 76.1 mm 3.000 76.1 1.8 3 - 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 284 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 4 4.3 65.1 mm 6.500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 1 5.8 10.81 5662 Rev I Updated 07/2020 0 2020 Victaulic ComDany. All rights reserved. victaulic.com 5.1 PERFORMANCE Series 705 Cv values for flow of water at +600F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, values Formulas for K values AP = Where: AP = Q2 Q = Flow (GPM) AP j -- AP = Pressure Drop (psi) Q = C x -/AP C= Flow Coefficient Q = K Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches c mm mm 2 2.375 170 50 60.3 21/2 2.875 260 65 73.0 76.1 mm 3.000 260 76.1 3 3.500 440 80 88.9 4 4.500 820 100 114.3 108mm 108mm 820 5 5.563 1200 125 141,3 133 mm 133 mm 1200 139.7 mm 35 1200 6 6.625 1800 150 168.3 159 mm 159 mm 1800 165.1 mm 6.500 1800 165.1 8 8.625 3400 200 219.1 10 10.750 5800 250 273.0 12 12.750 9000 300 323.9 Where: Q = Flow (m3/hr) AP = Pressure Drop (Bar) K = Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches K mm mm 2 2.375 147 50 60.3 2½ 2.875 225 65 73.0 76.1 mm 3.000 225 76.1 3 3.500 380 80 88.9 4 4.500 710 100 114.3 108mm 108mm 710 5 5.563 1040 125 141.3 133 mm 133 mm 1040 139.7 mm 5 .500 1040 139.7 6 6.625 1560 150 168.3 159 mm 159 mm 1560 165.1 mm 6 .500 1560 165.1 8 8.625 2940 200 219.1 10 10.750 5020 250 273.0 12 12.750 7790 300 323.9 10.81 5662 Rev I Updated 07/2020 © 2020 Victaulic Company. All rights reserved. N t,iefiiIir rnm 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring The supervisory switch contains two single pole, double throw, pre-wired switches. Switches are rated: 10 amps © 125 or 250 VAC/60 Hz 0.50 amps © 125 VDC 0.25 amps © 250 VDC Switches supervise the valve in the "OPEN" position. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 insulated ground lead (green) is provided. Switch #1 = Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe FWNPT VINE NUIS FIRE ALARM OR NEXT INDICATOR CONTROL PANEL L TO END-OF-LINE RESISTOR, SUPERVISORY CIRCUIT COM, SWITCH CONTACT RATING bA AT 125 AND 2SOVAC, S2 BELL 0.5AAT12SVDC, 025 AT 250 VDC ORN OR VOLTAGE SOURCE H Switch 1:2 leads per termina Switch 2:1 lead per terminal NOTES The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe —S2) and the normally closed terminal (blue - Si and blue-with-orange stripe - S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). 10.81 5662 Rev I Updated 07/2020 0 2020 Victaulic Company. All rights reserved. ff victaulic.com 7.1 REFERENCE MATERIALS 1001: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty 1-100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or ass recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Viclaulic products, providing complete installation and assembly data, and are available in POE format on our website at www.victaulic.com, Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.81 5662 Rev I Updated 07/2020 0 2020 Victaulic Company, All rights reserved. A C@ t Overall Height LISTED B Center of pipe to top of knurled hanger rod nut. D Top of pipe to bottom of hanger rod nut. <1 APPROVED Fig. 2OO-/2& I44 200-3/4 i;\\ 41,-- 201to" 1 200-2 Pipe Hangers TOLCOTM Fig. 200 - Trimline" Adjustable Band Hanger TOLCOTM Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCOTM Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated TOLCOTM Fig. 200S - "Trimline" Adjustable Band Hanger with Removable Nut (For sizes 1" thru 2") Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 1/2" (15mm) thru 2" (50mm) sizes have flared edges for ease of installation on all pipe types and protects CPVC plastic pipe from abrasion. Captured knurled nut design (flared top) on 1" thru 2" sizes keep nut from separating with hanger. Hanger is easily installed around pipe. 1/2" (15mm), 3/4" (20mm), and 21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. For 1/2" (15mm) and 3/4" (20mm) sizes with non-captured knurl nuts order Fig. 200S Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°c) 17W Agaw Finish: Pre-Galvanized. Stainless Steel ..-J materials will be supplied with (2) hex nuts r / in place of a knurl nut. Order By: Part number and pipe size ** Note: For metric hanger rod sizes add the metric rod size to the figue number. Example: 200M8-11/2 or200M10-1V2 Fig. 200C Fig. 200F t M8 rod size is not UL Listed or FM Approved 200C-11/2 shown 200E-11/2 shown 0 0 0) Fig. 200 Fig. 200 & Fig. 200S shown with captured nut shown with 1" thru 2" sizes only non-captured nut Pipe Size Rod Size A B 0 Max. Rec. Load Approx. Wt./100 Part No.** in. (mm) in. mm in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200-1/2 1/2" (15) /8"-16 M8t or M10 31/8" (79.4) 2/8" (66.7) 111/32" (34.1) 400 (1.78) 11 (5.0) 200-/4 3/4" (20) /8'-16 Wt or M10 31/8" (79.4) 21/2" (63.5) 11/16" 127.01 400 (1.78) 11 (5.0) 200-1 1" (25) I8'-16 Wt or M1O 3/8" (85.7) 2/8" (66.7) 11/8" (28.6) 400 (1.78) 12 15.51 200_11/4 11/4" 1321 /811-16 M8t or M10 33/4" (94.0) 2/8" 173.01 1/32" (29.3) 400 (1.78) 13 (5.9) 200-11/2 11/2" (40) /8"-16 Mt8 or M10 3/8" (98.4) 2/8" (73.0) 1/16" (30.2) 400 (1.78) 14 (6.4) 200-2 (50) /8"-16 M8t or M10 41/2" (114.3) (76.3) 1/16" (30.2) 400 (1.78) 15 (6.9) 200-21/2 21/2" (65) /8"-16 M10 5/8" (142.9) 41/8" (104.7) 1/16" (36.5) 600 (2.67) 27 (12.3) 200-3 3" (75) /8"-16 M10 5/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) 200-31/2 31/2" (90) /11-16 M10 7 /8" (187.3) 51/4 (133.3) 2/16" (55.6) 600 12.671 34 (15.6) 200-4 4" (100) /811-16 M10 7/8" (187.3) 5" (127.0) 1/8" (34.9) 1000 (4.45) 35 (16.0) 200-5 5" (125) 1/2"_13 M12 91/8" (231.8) 61/4" (158.7) 311/32' (84.9) 1250 15.561 66 (30.2) 200-6 6" (150) 1/2'_13 M12 101/8" (257.2) 6/4" (171.4) 2/32" (56.3) 1250 (5.56) 73 (33.4) 200-8 8" (200) 1/2"..13 M12 131/8" (333.4) 8/4" (222.2) 37/33" (81.7) 1250 (5.56) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 23 Eaton TOLCOTM Fig. 25 - Surge Restrainer Pipe Hangers TOLCOTM Fig. 1CBS - Clevis Bolt Spacer Size Range: Size 1" (25mm) thru 20" (500mm) clevis hanger Material: Steel Function: Used as a spacer at a seismic brace location to keep clevis hanger from collapsing during seismic event. Approvals: Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines OPM-0052-13, for 21," -8" (133100) only Installation Note: Fig. 1 CBS fits easily over the cross bolt and attaches by pinching tabs down. Finish: Pre-Galvanized. Contact customer service for alternative finishes and materials. / Order By: Figure number and finish. Sizes 1")25) thru 11/2" (401 Size Range: - One size fits 3/4" (20mm) thru 2' (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2016 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" )20mm) thru 2" 140mm1. Patent #5,344,108 Approx. Wt./100 Part No. lbs. (kg) 25 4.8 (2.2) Sife Approx. Wt./100 Part No. (mm) lbs. (kg) 1CBS-1 (25) 3.2 (1.4) 1CBS.1j.s (32) 4.1 (1.8) 1C 8 /2 11/2" (40) 4.8 (2.2) 2" 1501 9.4 (4.2) 1 CBS-21/2 21/2" (85) 11.4 (5.2) 1CBS-3 3', (75) 13.9 (6.8) 1CBS-3'/2 31/2" (90) 16.0 (7.2) 1CBS-4 4" (100) 18.0 (8.1) 1CBS-5 5" (125) 27.3 (12.4) 1CBS-6 6" (150) 32.5 (14.7) 1CBS-8 8" (200) 42.5 (19.2) 1CBS-10 10" (250) 72.7 (32.9) 1CBS-12 12" (300) 86.3 (39.1) 1CBS-14 14" (350) 151.6 (71.5) 1CBS-16 16" (400) 183.7 (83.3) 1CBS-18 18" (450) 224.6 (101.9) 1CBS-20 20" (500) 254.0 (115.2) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in -millimeters unless otherwise specified. Eaton Revised 8/8/20/4 22 B-Line series Fire Protection Solutions Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) B32051 - Threaded Rod (right & left hand threads) Size Range: 3/8"-16 thru 7/8"-9 rod Material: Steel Length Function: Recommended for use as a hanger support in hanger assemblies. ,i Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. 83205L when ordering. Maximum Temperature: 750°F 399°Cl Finish: Plain or Electro-Galvanized. Contact customer service for alternative Thread Size finishes and materials. Order By: Figure number, rod size, length and finish Stakd Design Load Thread Size Thr Length IL 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 X 3/8'-jfr" 21/2' (63.5) 730 (3.25) 572 (2.54) B3205-1/2 X )113 21/2 (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x L' /8"-11 21/2' (63.5) 2160 (9.61) 1692 (7.52) B3205-31 /4"-10 3' (76.2) 3230 (14.37) 2530 (11.25) B3 _1/8 X /8'-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) or larger sizes consult full line pipe hanger catalog. AIR - All Threaded Rod - 120" (3.05m) Lengths TOLCOTM Fig. 99 - All Threaded Rod Cut To Length Size Range: 1/4'..20 thru /8'-9 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Approvals: Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For - additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Order By: Figure number, rod size, length and finish Part No. - Size x Length ATR Fig. 99 Threads Per Inch Recommended Load Lbs. lkNl Approx. Wt/100 Ft. Lbs. (kg) ATR 1/4" x 120 99.1/4" x length 20 240 (1.07) 12 (5.44) AIR /8" x 120 993/8" x length 16 730 (3.24) 29 (13.15) ATR 1/2" x 120 99.1/2" x length 13 1350 (6.00) 53 (24.04) ATR 5/8" x 120 99-/8" x length 11 2160 (9.60) 89 (40.37) ATR 3/4" x 120 99.3/4" x length 10 3230 114.371 123 (55.79) ATR 1/g" x 120 99-/8" x length 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 96 B-Line series Fire Protection Solutions Seismic Brad TOLCO Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" (FM Approved) OPM <*> Size Range: One size fits bracing pipe 1' (25mm) thru 2(50mm), B-Line series APPROVED 12 gauge (2.6mm) channel, and all structural steel up to 1/4' (31.7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections NFPA 13 (2016) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the 'bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 3000, 4L, 4LA, or other TOLCO approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Approved by Factory Mutual Engineering (FM). Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. For UL Listed information refer to UL Listed page 60. Note: Fig. 980 Swivel Attachment and Fig. 1000, 1001, 4L, 4LA or other TOLCO approved attachment to pipe that make up a sway brace system of bracing materials which satisfies the requirements of Factory Mutual Engineering and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Fig. 1001 Contact customer service for alternative finishes. K Set Bolt Included Mounting Hardware Is Not Included / Fig. 980 Fig. 4L Brace Lateral Brace Order By: Figure number and finish. Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Designed to meet or exceed requirements of FM DS 2-8. ice Part Mtg. Hdw. Mounting Hole Max. Design Load** (FM) Approx. Number Size A B D 300 440 450590 60°-740 750900 Wt./100 in. (mm) in. (mm) in. (mm) in. (mm) lhs./(kN) lbs./(kN) IbsJ(kN) lbsj(kN) lbs. (kg) 980-/8 /8" (9.5) 51/4" (133.3) 1/8" (47.6) 13/32" (10.3) 149 (67.6) 980_1/2 * /2" (12.7) 51/4" (133.3) 1/8" (47.6) 17/32" (13.5) 1320 1970 2310 2550 148 (67.1) 980-/8 /8" (15.9) 51/4" (133.3) 1/8" (47.6) 11/16" (17.5) (5.87) (8.76) (10.27) (11.34) 147 (66.7) 980-/4 3/411(19.0) 51/4" (133.3) 1/8" (47.6) 13/16" (20.5) 146 (66.2) * Standard size. ** Installed with 1" or 11/4" Schedule 40 brace pipe. FM Approved design loads are based on ASD design method. important - For load information when using Fig. 980 with pre-installed or post-installed concrete anchors in compliance with NFPA 13 (2016) or ASCE 7-10, including prying factors, see page 106. Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise B-Line series Fire Protection Solutions 61 Eaton OPM APPROVED q.t flnit R. In.Indnd Seismic Braci TOLCOTM Fig. 4L - Longitudinal In-Line Sway Brace Attachment (FM Approved) Size Range: 21/2 (65mm) through 8 (200mm) IFS. Material: Steel Function: For bracing pipe against sway and seismic disturbance Approvals: Approved by Factory Mutual Engineering (FM), 21/2 (65mm) through 8" (200mm) pipe. For UL Listed information refer to UL Listed page 74. Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Installation Instructions: Fig. 4L is the braced pipe attachment component of a longitudinal sway brace assembly. It is intended to be combined with the bracing pipe and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or FM guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage 'bracing pipe into jaw opening and tighten set bolt until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM DS 2-8. Pipe Max. Rec. Load (FM) Approx. Part Size A C 0 Bolt Size 300-440 450 590 600740 750 900 Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kg) 41_21/2 21/2' (65) 6/16" (163.5) 21/2' (63.5) 2/4' (69.8) 1/2"_13 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 253 (114.7) 4L-3 (80) 7' (177.8) 2/4' (69.8) 31/16" (77.8) 1/2'_13 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 268 (121.5) 414 (100) 81/2' (215.9) 3/8' (85.7) 311/16(93.7) 1/2'_13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 348 (157.8) 41-5 5 (125) 93/4 (247.6) 3/8" (98.4) 4/' (1111) 1/2'_13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 380 (172.3) 41-6 6' (150) 111/2' (292.1) (127.0) 51/8' (130.2) 1/2"_13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 640 (290.3) 41-8 8' (200) 131/4' (336.5) 5/8' (142.8) 5/8' 1142.91 1/2'_13 490 (2.18) 680 (3.02) 830 (3.69) 930 (4.13) 728 (330.2) FM Approved when used with 1 ', 11/4', 1 1/a' or 2 Sch. 40 brace pipe. FM Approved design loads are based on ASD design method. * UL Listed not FM Approved. Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise B-Line series Fire Protection Solutions 75 Eaton OPM APPROVED Seismic Bracing TOLCO Fig. 1001 - Sway Brace Attachment (FM Approved) Size Range: Pipe size to be braced: 1' (25mm) thru 8 (200mm) IPS. Pipe size used for bracing: 1 (25mm) and 11/4" (32mm) Schedule 40 lPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedule 7 through schedule 40 IFS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Approved by Factory Mutual Engineering (FM). Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHFD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. For UL Listed information refer to UL Listed page 66. Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" )25mm) or 11/4' (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the FM Approval requires that Fig. 1001 must be used only with other TOLCO bracing products. Designed to meet or exceed requirements of FM DS 2-8. .4" Pipe Size in. (mm) Part Number & Approx. Wt./100 1" (24mm) Brace Pipe 11/4" (32mm) Brace Pipe Lbs. (kg) Lbs. (kg) Design Load - For Sch. 1, Sch. 10, & Sch. 48 Pipe Allowable Horizontal Capacity (Ibi) Per Installation 300-440 450-590 60°-140 150-900 Lbs. (kN) Lbs. (kNI Lbs. (kN) Lbs. NN) (25) 1001-1 X 100.0 (45.3) 1001-1 X 11/4 118.0 (53.5) 1800 (8.00) 2550 (11.34) 3120 (13.88) 3490 (25.52) 11/4" (32) 1001_11/4 X 100.0 (45.3) 1001-11/4 X 11/4 114.0 (51.7) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 11/2" (40) 1001-1'/2 X 100.0 (45.3) 1001 -11/2 X 11/4 115.0 (52.1) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) (50) 1001-2 X 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9) 1230 (5.41) 1740 (7.74) 2140 (9.52) 2380 (10.58) 21/2" (65) 1001_21/2 X 1 138.6 (62.8) 100121/2 X 11/4 160.4 (72.7) 800 (3.56) 1130 (5.02) 1380 (6.14) 1540 16.851 (80) 1001-3 X 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) (100) 1001-4 X 1 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 6" (150) 1001-6 X 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" 12001 1001-8 X 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/T 3091,EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. Note: Metric sizes are available, contact factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 67 Eaton Seismic Bracing TOLCO Fig. 825 - bar joist sway brace attachment to steel (FM approved) Size Range: One size accommodates all Fig. 900 Series sway brace attachments. Material: Steel Function: To attach sway bracing and hanger assemblies to steel members. ,- Features: This product's design incorporates a concentric '1 attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importanceimportance of concentric loading of connections and fasteners. Permits secure non-friction connection without drilling or welding. Unique design reinforces point of connection to joist. Break off head set bolt design assures verification of proper installation torque (mm. 31 ft-lbs.). Approvals: Approved by Factory Mutual Engineering (FM). Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13 For UL Listed information refer to UL Listed page 54. Installation Instructions: Fig. 825 is the structural attachment componentof a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO" transitional attachment, 'bracing pipe" and a TOLCO "braced pipe" attachment, to form a complete bracing assembly. NFPA 13 or FM guidelines should be followed. To Install: Place the Fig. 825 on the steel beam, tighten the cone point set bolts until heads break off. Attach other TOLCO transitional attachment fitting, Fig. 980, 910, 909, or any other TOLCO approved transitional fitting. Transitional fitting attachment can pivot for adjustment to proper brace angle. Fig. 980 Top View (25.4mm) 1/2" Bolt & Nut Furnished Fig. 825 -...,. Finish: Plain, Electro-Galvanized and HDG Approx. Wt./100: 247.5 Lbs. (112.2kg) Order By: Figure number and finish US Patent #6,098,942, Canada Patent #2,286,669 Designed to meet or exceed requirements of FM DS 2-8. Fig. 41 Retaining strap not required. FM Approved design loads are based on ASD design method. Fig. 1000 Side View Fig. 1001 FM Approved Design Loads 300.440 45°59° 600.140 15°-90° lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) Maximum Perpendicularto 990 1360 1670 1860 3/0 Thick Flange Structural Member (4.40) (6.05) 17.431 (8.27) NBrace Maximum Parallel to 460 630 770 860 IN'Thick Flange Structural Member (2.04) (2.80) (3.42) (3.82) Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 55 Eaton Fire Sprinkler Hanging na roc! P 'C"t's, , 7~ Rm w a- 2 - "I M I I v 16 11: M - - NEW- ~ r~l • • --- _____ A Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1" (25 mm) through 2" (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlFns, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16" (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 800NO compared to other methods. Unlike most solutions that only accept 3/8" (M10) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3/8" or 1/2" (M10 or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2" (M12) threaded rod. The system meets the requirements of NFPA! 13, making it ideal for new construction applications. The total system is cULus Listed and FM' Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-10). 11 amenivyrzal.iMt MeOtMacynf"ean Features Accepts 3/8" or 1/2" (M 10 or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can be installed with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection I z I2i RS Il T 00 T 1-f ) Specifications Material: Steel Finish: Electro-galvanized c®us CSBBRPO100EG 1.32" 3/8", 1/2' 6.67" 1.63' 0.88" CSBBRP0I25EG 1 1/4" 1.66" 3f8", 1/2" 7.56" 1.97" 0.88" CSBBRP0150EG 11/2" 1.90" 3/8", 1/2" 8.20" 2.21" 0.88" CSBBRP0200EG 2.38" 3/8", 1/2" 9.45" 2.69" 0.88" U a 71 94 www.erico.com Features Swivel connector accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to concrete anchors or structural attachments with female threads QS Specifications Material: Steel Finish: Electro-galvanized c®us ~j WRTII~izel - - ,~JWRen~gthjj "ErWk."tWhI SZTFW7Di crew en9t Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. rff ,1n1IF;v www.erico.com 97 tL/Lt6Y c®US LISTED APPROVED r 1 Per NFPA 7 1 - 3/8" or 1/2" Lag Bolts Up to 4" (100mm) pipe 2- #16 x 2" Drive Screws /2 (15mm) -4" (100mm) pipe Pipe Size üty UL Listed Fastener Table Fastener Type Material 2 2 #16 x 2" Drive screws Wood 2' 1 /8 Lag bolt Wood 21/2" - 4" 1 1/2" Lag bolt Wood 31/2" 2 1/4" X 11/2' Lag bolts Wood 4" 2 1/4 x 2" Lag bolts ** Wood 4 2 1/4" x 1" Tek screws Metal (15 gauge) 4 2 1/4 x 1" Tek screws Metal (16 gauge) ** No pre-drilling Up Uiet Attachments' TOLCOTM Fig. 58 - Threaded Side Beam Bracket Size Range: /8"-16 rod, pipe sizes 1/2" (15mm) thru 4(100mm) Material: Pre-Galvanized Steel Function: Practical and economical bracket used to support piping from wood, concrete or steel beams. Features: Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept /8" and 1/2" fastener bolts. Per NFPA 13: 1/2" (15mm) thru 2 (50mm) pipe requires /8" fastener, 21/2 (65mm) thru 4 (100mm) pipe requires 112" fastener.* Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" (100mm) pipe. Finish: Pie-Galvanized Order By: Figure number and finish *Note: Additionally UL has listed the Fig. 58 with fasteners as shown in table below. 2 1/4" x 2 Lag Bolts (No Pre-Drilling Up to 4" (100mm) pipe 2- #14 x 1" Tek Type Screws Larger pipe sizes can be hung with reduced spacing Part No. Pipe Size Rod A B C Approx. Wt./100 in. (mm) Size in. (mm) in. (mm) in. (mm) Lbs. (kg) 58 1/2 -4" (15 -100) /8'-16 2/4" (69.8) 1 1/2 (38.1) 1 1/8" - (28.6) 14 (6.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 91 Eaton D EWA FTO ENGINEERED BY ?owers I W mu r Hanqermater+ A . DEWALT ITW BUI iex Hrgermate+ Sanrrys5 Suspender Nc '99i'ii Yes All 2-piece I iJiUh1Ti*Il 12 SKIJS "On select sizes with coupling rut - Sammys is a registered trademark of Ill nois Tool Works In. tallahon river Referene . DESCRIVICtJ PHangerrnate+05 D5IVE teel - Vertical 1/4-20 143 PFM0 00 00 11 1/4-20 x #3 PFM220 200 I 1/4-20 x / nut PFM220 CO 1/4-20 x 1_112 #5 PFM2202C0 1/4-20x1-1I2 45 /nut PFM22012G0 I 1/4-20 xl - 2 #3 PFM22012C0 I l/4-20x1-1/2"#3/nut PFM2201200 _ 1/4-20x2#3 PFM2201200 Hangermate+ Steel - HorizonII 00 1/4-20 x #3 PFM2201200 ON, 1/4-20x1 43/nut PFM220200 1/4-20 xl -.2 #3 PFM220 200 • 1/4-20x1-1t243/nut I PFM220200 U 1/4-20 x -1i2" #5 PFM220 200 I 1/4-200-1,2' #5 /nut PFM2201200 Pivot Steel - Angled Applicatiois 1/4-20 x 1' #3 PFM2201250 1220x13/l"#5 Suspender leel - Dual-Directio-ial 1/4-20 x 03/ nut PFM2201330 IQ'J i74Ox1-i/T Tiut PFM22013J0 1/4-20 xl -l/~5 / nut PFM2201330 SteeI AcoustiaI Ceiling Screw Eyelet 1idi I - r ft __ Z J& 1 ." ,- • -•• I I- Jill J: J!4• rE!' Al "•Li•' r Th Steel Socket (Silver) Rod Hanger 1 5 Suspender Driver Suspender 1 5 Pivot Driver P vat 1 5 Ceiling Screw Eyelet Driver ?,cousti:al 1 5 ?ole Tool Kit Fad Harger 1 5 Adapter for hanging 1/2' rod (3/8" to 1/2" Adapter) 23 V MAX* XR Lithium Ion Brushlcsa 3-Speed Dill / Driver lit 20V MAX* XR 1/4" 3-Speed lirlpac: Drker Kit DESCRIPTION SAMMYS® MODEL # HANG ROD SIZE OTY F"STR QTY Hangermate+ For Steel - Vertical PFW231 000 1/4-20 Y#3 DSTR 100 Vertical 1/4 25 125 U 1!4-0 xl" #3 - Vertical 3/8 25 125 ON 1/4-20 xl' 43 / nut DSTR 1 Vertical 3/8 25 125 I 1/4"-20x1-1/2" #5 DSTR 1-1/2 Vertical 3/8 25 125 PFM223115N 1/4-20 x 1-1/2k #5/nut DSTR 1 Vertical 3/8 25 125 11011 01111 U 1/4-20x 1-112' #3 - Vertical 3/8 25 125 1 1/4-20x1-1/2" #3/nut DST15 Vertical 3/8 25 125 I 1/4-20 x 2 #3 DST 20 Vertical 3/8' 25 125 Hangermate+ For Steel - Horizontal U 1/4-20 xl #3 SDW 10 Uorizota 3/8" 25 125 I1224 1 2241 1 ON 1/4-20 x 1" #3 / nut SDWR 1 Horizola 3/8" 25 125 II 1/4-2&x 1-1!2" #3 - Horizota 3/8' 25 125 I' 1/4-20x 1-1/2' #3 /nut - - III Horizota 3/8" 25 125 PFLA2241200 1/4-20 x 1-1!2" #5 SWT 15 Horizo-ta 3/8" 25 125 • 1/4-20 x 1-1,2" #5 /nut SWDR 1-1/2 Hotizota 3/8" 25 125 Hangermate+ Pivot For Steel - Angled Applications L'I 1/4-20 xl' #3 SH-DSTR 1 Variable 3/8" 25 125 PFM2281200 12-20x 1-3/4" #5 SH-TEK 50 Variable 3/8" 25 125 .1.0 1/4-14x1'#3 - Variable 3/8" 25 125 Hangermate+ Suspender For Steel - Dual-Directional ir1fflI'l 1/4-20 x I " #3/nut - Je-t. & Horz. 3/8" 25 125 ' 1/4-20x1-1/2"#3/nut - /e:t&Horz. 3/8" 25 125 I 1/4-20 x 1-1/2" #5/ nut - Je. & Horz. 3/8" 25 125 Hangermate+ For Steel - Acoustical Ceiling Screw Eyelet 1/4" x 3" CWSD 1 'Jet. & Horz. Eyelet Hcie 25 125 4' II 111111111 Pl19I 1/4' x 3-1/4" CWSD 2 Vert. & Horz. 3/16 25 125 Recommended 13C0 to 2000 rpms for proper installation. rue uompiete Ancnoring soiuiion - insiauaiion accessories ana ioos IUI.IItl1;I DESCRIPTION hN'JGERMATE— QY MSTR QTY *Maximum nitial t3ttery voltage (measured without a workload) s 20volft. Nominal vt tage is 18 7 Specialty Rod Hanging Anchors If Suspenderm c 'C L. I. MULTIPLE THREADS different thread and point styles I ' TwJN:'. p .TOR . - ............ threa enga e (conc e wj) PR227iOC'O PfM22711QN PfM2271 20N I Hangermate+ For Steel - Vertica APPROVALS Ci) <> ULTIMATE t IsIeEIu1I:I:1 DESCRIPTION I-NG ROD DRIVER MIN. MAX. TENSILE LOAD LOAD PIPE UL PIPE FM SIZE THICK THICK. (MATERIAL DIRECTION SIZE THICK. SIZE THICK. THICKNESS) iDhIIII 1/4-20 1" #3 Vert. 1/4 PFM220i200 0.060 0250 2,375 (0.125") V 4" 0.125" 4 12 ga. flDDI /4-20x1"#3 Wert. 3/8" PFM2201200 0.060 0250 2,375(0.125') V 4" 0.060" 4' 16 ga. PiI1III 1/4-20 xl" #3/nut k eft. 3/8' PFM2201200 0.060 0250 4,690 (0.125') V 4' 0.125" 4' 12 ga. fllII 1/4-20 x 1-1/2" #5 Vert. 3/8" PFM2201200 0.188 0250 3,675 (0.188") V 4" 0.060" 4 16 ga. iIlI 1/4-20 x 1-112" #5/nut Vert. 3/8' PFM2201200 0.060 0250 5,810 (0.188") V 4" 0.125" 4.' 12 ga. W1IIII 1/4-20 xl-1/2" #3 Ve. 3/8' ?FM22:31200 0.18;3 0250 2,375. (0.125") V 4" 0.060' 4" 16 ga. /4-20 x 1-1/2" #3/nut Vet. 3/8" PFM2231200 0.060 0250 4,690 (0.125") V - - 4" 0.125" 1/4-20 x2" #3 Val. 3/8" PFM22:1200 0.060 0.250 2,375 (0.125") V Hangermate+ For Steel - Horizontal VF!PUhiItI 1/4-2C x - "#3 Horiz. 3/8" PFM221200 0.060 0.250 2,57C (0.111") H - - - - KIIII1I 1/4-20 Y. 1'"# /nut Hori. 3/8" PFM221200 0.060 0.250 2,810 (0.111") H 4" 0.060" 4" 16 ga. K&Ii1II 1/4-20 x 1- /2" # Horiz. 3/8" PFM221290 0.060 0250 2,570 (C.1 11") H - - - - III1I 1/4-20x1-0/2"#3/nut Horiz. 3/8" PFM22C120 0.060 0250 2,81C(C.111") H 4" 0.060" 4" 16 ca. 1/4-20 x 1-1/2' #5 Horiz. 3/8" PFM2201200 0.060 0.500 3,530 (0.188") H - - - - 1/4-20 x --/2" #5/nut Horiz. 3/8" PFM2201200 0.060 0.500 2,810 (0.111") I Fl 4" 0.060" 4" 16 ga. Hangermate+ Pivot For Steel - Angled Applications ") Put1lI 1/4-20 x " #3 VaabIe 3/8" PFM2201250 0.060 0.188 3,210 (0.188 V - - - - 975',0.188") 450 - - - - P1•III 12-20 x 1-3/4" #5 Vaiable 3/8" PFM220250 0.11 0.188 3,270 (C.188") V - - - - 975 0.188") 45° - - - - A3P1lI 1/4-14 x " #3 Va1aIe 3/8" PFM220250 0.188 0.5 2,875 (0.188") V - - - - 875 0.188") 1 45° - - - - ispender For Steel - Oval-Directional Vt.& V 4" 0.060" 4" 16 ga. 1/4-20 xl" #3/nu: 3/8" PFM22C1300 0.060 0.210 4,690 (C.125")Hrz. H 4" 0.060" 4" 16 ga. V rt. & V 4" 0.060" 4" 16 ga. 1/4-20 x 1-/2" #3/rut 3/8" PFM22C1300 0.060 0210 4,690(0.125")Horz. H 4" 0.060" 4" 16 ga. V It. & V 4" 0.0600 4" 16 ga. - /4-2C x 1-it?" # rut 3/8" PFM22C1300 0.188 0.500 4,690 (C.1 25") H 4" 0.060" 4" 16 ga. Hangermate+ For Steel - Acoustbal Ceiling Screw Eyelet 1/4" x 3" 3/16" PFM22C135O - 0)60 590 (0.188") - - - - - 'JkW. W1 1/4"x3-1/4 3/16" PFM2201350 - 0.0€0 590 (0.188") - - - - - Loads vi" depending on steel ti-ickness. Contac DE'fl,Lr for more inornation. 3 Head Box Heavy duty 20 gauge steel construction (6510152) 6 Read Box 6 Large Head Box (6510151A) (6510151) NOWN low WMI -51 W - FIRE SPRINKLER SPARE HEADBOXES 12 Head Box (6510150) Red powder coated finish Knockouts and shelf to accommodate any 1/2" or 3/4" sprinkler head All-welded construction and full length hinge Slotted for easy mounting with screws, rivets or strapping The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM ARGCO VINYL SPRINKLER IDENTIFICATION DECALS -White Vinyl Crack and Peel Decals with Bright Red Ink. 'Available as generic signs or personalized. 'ID signs, inspection decals, hydracalc placards and services stickers. AIR CONTROL 50-20-010 AIR LINE 50-20-020 ALARM LINE 50-20-03U ALARM TEST 50-20-040 ANTIFREEZE SYSTEM] FIRE EXTINGUISHER 50-20-045 50-20-200 AUXILIARY DRAIN FIRE DEPARTMENT VALVE 50-20-070 50-20-201 CONTROL VALVE FIRE HOSE 50-20-100 50-20-205 DRAIN VALVE [FIRE SPRINKLER L PIPE 50-20-140 50-20-221 FIRE PROTECTION 8" x 2" 50-20-219 INSPECTORS TEST 50-20-270 MAIN CONTROL 50-20-280 MAIN DRAIN 50-20-290 1 P EN SPRINKLER CONTROL 50-20-300 SPRINKLER 50-20-317 TEST & DRAIN 11 50-20-355 WATER MOTOR LINE] 50-20-390 SPRINKLER] 50-20-541 SPRINKLER 50-20-542 50-20-410 HYDRU1!FCTSVSTEM TiIdiis protected bya HWS9iicaIIy'Designed Location No. tSprinklers Basis of Design System...Demand SERVICE STICKERS ' A*ARICCANCm Put your Company Name & Logo on your Service Decals A Great Way to Advertise Right on the Jobsite " ARGCO's art department can take your personalized artwork and recreate it on your signs -SP RP. N$FBIPtttCfltN 1124 HR. EMERGENCY SERVICE I 715W0100flfl Custom to your specs. I 770.339.3737 The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM