Loading...
HomeMy WebLinkAbout5823 NEWTON DR; ; FPC2017-0331; PermitIi 1 i 1I:i1 I.]4I 4LICIty of Carlsbad Print Date: 12/14/2020 Job Address: 5823 NEWTON DR, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel U: 2120504300 Track U: Valuation: $1,119,960.80 Lot #: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Project Title: Description: THERMO-FISHER -SPRINKLER (PHASE 1) WAREHOUSE TO OFFICE Permit No: FPC2017-0331 Status: Closed - Finaled Applied: 11/14/2017 Issued: 11/30/2017 Finaled Close Out: 12/14/2020 Inspector: Final Inspection: FPContractor: MILLENNIUM FIRE PROTECTION CORP - INACTIVE 2950 SAN LUIS REY RD OCEANSIDE, CA 92058-1241 (760) 722-2722 FEE AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours $198.00 FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 FIRE Reinspection (per inspection) $187.00 Total Fees: $921.00 Total Payments To Date: $921.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I - MILLENNIUM FIRE PROTECTION CoFp, THL"A'-.1-10 F:-IS-HER E. ft 7 ON BLD G 5823 Overhead Fire Sprinkler Material Submittal ORIGINAL SUBMITTAL 1/26/2018 FPC20I7-0331 5823 NEWTON DR THE RMO-FISHER - SPRINKLER (PHASE 1) WAREHOUSE TO OFFICE 2120504300 2/1/2018 FPC20I 7-0331 ENO SPRINKLER HEAD Jmt ,duded i-i ARGCO ItN, ARGCO BR29 Braided Flexible Fire Sprinkler Drop 'Larger inner diameter for better flows 'Save Time & Money 'No cutting, no welding, no threading 'Perfect for retrofit applications 'Easy to move for layout changes C @ us <C ~S>us LISTED APPROVED UL Listed FM Approved ARGCO Flexible Sprinkler Hose is designed to be used in wet sprinkler systems between the branchline and sprinkler when installed in accordance with NFPA 13,13D, and 13R. Stainless steel braiding over the outside of the tube provides additional mechanical protection to the drops and is required to resist system pressurisation. ARGCO's 29B provides a unique sprinkler drop assembly comprised of the following components: 304 Stainless Steel Flexible Hose with Two Slip Nuts Branchline Inlet Nipple NPT (BSPT available) Straight Outlet Sprinkler Reducer (90 degree reducer available) NPT (BSPT available) Center Bracket, End Brackets, and Square Support Bar TECHNICAL DATA UL Listed FM Approved 'Rated Pressure: 175 PSI (12.5 Bars) 'Max. Service Pressure: 200 PSI (14 Bars) 'Maximum Ambient Temperature: 225°F (107°C) Maximum Sprinkler K-factor for ½" outlet: 8.5 Maximum Sprinkler K-factor for 3/4" outlet: 14.0 'Designed for use in wet systems 'Flexibility Type: Unlimited 'Hose Diameter: 28.2 mm I.D, 28.8 mm O.D. 'Minimum Bend Radius: 6" UL, 9" FM Anchoring components are intended for use with drop ceilings conforming to ASIM C635 and other major standards when installed in accordance with the standard practice for installation of metal ceiling suspension systems for acoustical tile and lay-in panel, ASTMC C635 or other equivalent standards. phone800-854-1 015 argco.com fax800-924-5922 7/12/2017 ARCO BR29 Braided Flexible Fire Sprinkler Drop Friction Loss Data and Specifications BRAIDED 1/2"NPT 3/4"NPT c@ us Equivalent Length of Equivalent Length of 1 ft Sch 40 Pipe 1 ft Sch 40 Pipe LISTED APPR8V UL FM UL I FM Lncith ITEM I itpd AnnrnvI. ITEM Listed AnnrovI ~~w Maximum # of 900 Bends UL FM I ictcd I AnnrnuI AR-B FLEX-07 28" (0.6 m) 6530165 6 ft 23.0 ft 6530175 lift 16.1 ft 1 1 AR-13 FLEX-10 39" (0.9 m) 6530166 14 ft 33.5 ft 6530176 16 ft 27.4 ft 1 2 AR-B FLEX-12 48" (1.2 m) 6530167 22 ft 40.5 ft 6530177 30 ft 35.0 ft 2 2 AR-B FLEX-15 60" (1.5 m) 6530168 29ff 44.9ff 6530178 38 ft 39.3 ft 2 3 FLEX-187—r--y 3. 14fF TU 2 Bend Characteristics [sTh:1Ti Two Sends 2X M;rrrrurn bend radius OR Three Bends / bend id,us Mrnrwrn end nndiun ED .nrn,jm d radius Morirutrr •_/ M,nhnurn bend rdus bend 'Um Minirnnrn bend fadius phone800-854--1 015 argco.com fax800-924-5922 I 7/12/2017 J7 BR29 Braided Flexible Fire Sprinkler Drop 81INCIP, 14)91 c UL us LISTED APPROVED 28.8 mm INNER DIAMETER 304 STAINLESS STEEL HOSE FOR BETTER FLOW CHARACTERISTICS. 110 mm 1"x 1/2 or 1"x3/4" OUTLET NIPPLE HINGED CENTER BRACKET FOR QUICK AND EASY INSTALLATION 58 or 98 mm END BRACKETS FOR DEEP AND SHALLOW INSTALLATIONS. TIGHTENS WITH PHILLIPS HEAD SCREW DRIVER. 900 ELBOWS AVAILABLE 1/2": Item #6530190S 3/4": Item #6530192S ARGCO'S B29 Flexible Sprinkler Hose Assemblies are designed to be used in wet sprinker stystems between branchllne and sprinkler when installed in accordance with NFPA 13, 13D and 13R. User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of ARGCO products for a particular end-use application, in accor- dance with industry standards and project specifications, and the applicable building codes and related regulations as well as ARGCO performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any ARGCO employee, shall be deemed to alter, vary, supersede, or waive any provision of ARGCO's standard conditions of sale, installation guide, or this disclaimer. ARGCO reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Warranty Refer to the Warranty section or contact ARGCO for details. phone800-854-1 015 argco.com iax800-924-5922 7/1212017 Millennium Fire Protection 2950 San Luis Rey Road Oceanside, CA 92058 (760) 722-2722 Job Name : 17-055 BLDG 5823 NEWTON PHASE I Building : FP-004 Location : 5823 NEWTON DRIVE, CARLSBAD, CA 92008 Remote Area : I Contract : 17-055 Data File : 17-055 BLDG 5823 NEWTON PHASE I Area 1.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Millennium Fire Protection Page 17-055 BLDG 5823 NEWTON PHASE I Date HYDRAULIC CALCULATIONS for Project name: 17-055 BLDG 5823 THERMO FISHER PHASE I Location: 5823 NEWTON DRIVE, CARLSBAD, CA 92008 Drawing no: FP-004 Date: 11/07/2017 Design Remote area number: 1 Remote area location: HYDRAULICALLY MOST DEMANDING Occupancy classification: B, S-i Density: 0.10 - Gpm/SqFt Area of application: 1507 - SqFt Coverage per sprinkler: 192 - SqFt Type of sprinklers calculated: STANDARD QUICK RESPONSE No. of sprinklers calculated: 13 In-rack demand: - GPM Hose streams: 100 -GPM Total water required (including hose streams): 370.442 -GPM @ 87.9448 - Psi Type of system: STANDARD -WET Volume of dry orpreaction system: -Gal Water supply information Date: Location: 5823 NEWTON DRIVE Source: CITY OF CARLSBAD Name of contractor: Millennium Fire Protection Address: 2950 San Luis Rey Road I / Oceanside, CA 92058 Phone number: (760) 722-2722 Name of designer: BRYANT ARIAS Authority having jurisdiction: CITY OF CARLSBAD FIRE DEPARTMENT Notes: (Include peaking information or gridded systems here.) 10% ALLOWANCE INCLUDED IN CALC Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Millennium Fire Protection Page 2 17-055 BLDG 5823 NEWTON PHASE 1 Date City Water Supply: Demand: Cl - Static Pressure : 105 Dl - Elevation : 4.114 C2 - Residual Pressure: 78.4 D2 - System Flow : 286.657 C2 - Residual Flow : 1663.1 D2 - System Pressure : 81.670 Hose ( Demand) :100 D3 - System Demand :386.657 Safety Margin : 21.541 150 140 130 p120 R11° ei- E 100 S 90 - - C2 80 U 70 R6° E5° 40 30 20 ..D.4..--... I 10 I I I 200 400 600 800 1000 1200 1400 1600 1800 FLOW(NA 1.85) Computer-Prograrns by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Millennium Fire Protection Page 3 17-055 BLDG 5823 NEWTON PHASE 1 Date Fitting Legend Abbrev. Name 1/2 % 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 Avc Alarm Vic 751 0 0 0 0 3 9 8 17 0 21 0 22 50 0 0 0 0 0 0 0 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139O'StandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zac Ames 2000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD '1 'Millennium Fire Protection Page 4 17-05 BLDG 5823 NEWTON PHASE I Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. Hi 9.5 5.6 11.76 na 19.2 0.1 192 7.0 H2 9.5 5.6 9.0 na 16.8 0.1 168 7.0 H3 9.5 5.6 7.0 na 14.82 0.1 120 7.0 H4 9.5 5.6 7.0 na 14.82 0.1 100 7.0 H5 9.5 5.6 7.0 na 14.82 0.1 74 7.0 H6 9.5 5.6 7.0 na 14.82 0.1 60 7.0 10.0 K=K@K6 15.82 na 16.17 2 10.65 16.68 na 3 10.65 16.72 na 4 10.65 16.84 na 5 10.65 16.97 na 6 10.92 18.84 na 7 10.92 19.83 na 8 10.92 20.26 na 9 10.92 22.49 na 10 10.92 23.24 na ii 10.92 26.49 na 12 11.02 33.63 na 13 34.66 . 54.35 na 14 34.66 57.51 na 15 28.67 62.23 na 16 28.67 . 62.25 na 17 28.67 62.26 na 18 28.67 62.28 na 19 28.67 62.3 na 20 28.67 62.31 na 21 28.67 62.33 na 22 28.67 62.35 na 23 28.67 62.38 na 24 28.67 62.4 na 25 28.67 62.43 na TASR 28.67 62.62 na BASE -4.0 76.87 na TEST 0.0 81.67 na 100.0 26 10.0 KK@K6 15.86 na 16.1.9 27 10.0 K=K@K6 16.05 na 16.29 28 10.65 16.66 na 29 10.42 KK@K4 16.26 na 16.4 30 10.0 KK@K6 16.84 na 16.68 31 10.49 16.86 na 32 10.67 K= K@ K4 17.93 na 17.21 33 9.5 K = K@ K2 19.37 na 19.2 34 9.5 K= K@ K2 19.78 na 19.4 35 9.5 K = K @ K2 . 21.9 na 20.42 36 9.5 K = K @ K2 22.61 na 20.75 37 9.5 K= K@ K7 . 23.82 na 19.84 38 10.35 25.19 na 39 10.61 25.37 na 40 9.45 K = K @ K2 24.01 na 21.38 41 9.7 ' 25.26 na 42 10.05 . 25.16 na 43 9.5 K = K @ K2 24.0 na 21.37 44 9.5 K = K @ K3 24.98 na 21.09 45 9.5 K = K @ K3 33.08 na 24.27 46 34.35 59.78 na 47 34.35 59.76 na 48 28.67 62.22 na 49 28.67 62.22 na 50 28.67 ' 62.23 na 51 28.67 62.23 na 52 28.67 62.23 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard Millennium Fire Protection Page 5 17-055 BLDG 5823 NEWTON PHASE I Date Node No. Elevation K-Fact Pt Actual Pn Flow Density Area Press Actual Req. 53 28.67 62.24 na 54 28.67 62.24 na 55 28.67 62.24 na 56 28.67 62.25 na 57 28.67 62.25 na 58 31.45 61.06 na 59 31.45 61.21 na 60 28.67 62.21 na 61 34.66 58.96 na 62 34.03 59.9 na 63 34.03 59.94 na 64 33.7 60.05 na 65 33.7 60.09 na 66 33.38 60.19 . na 67 33.38 60.25 na 68 33.06 60.34 na 69 33.06 60.4 na 70 32.74 60.49 na 71 32.74 60.56 na 72 32.41 60.63 na 73 32.41 60.72 na 74 32.09 60.77 na 75 32.09 60.8 na 76 32.09 60.88 na 77 31.77 60.92 na 78 31.77 61.04 na The maximum velocity is 25.17 and it occurs in the pipe between nodes 12 and 13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 6 .17-056 BLDG 5823 NEWTON PHASE I Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn HI 19.20 1.049 EqI 24.0 5.000 11.755 K Factor = 5.60 to 120.0 0.0 24.000 4.114 K2 19.2 0.1207 0.0 29.000 3.500 Vel = 7.13 0.0 19.20 19.369 K Factor =4.36 H2 16.80 1.049 EqI 24.0 5.000 9.000 KFactor= 5.60 to 120.0 0.0 24.000 4.114 K3 16.8 0.0943 0.0 29.000 2.734 Vel = 6.24 0.0 16.80 15.848 KFactor 4.22 H3 14.82 1.049 EqI 24.0 5.000 7,000 K Factor = 5.60 to 120.0 0.0 24.000 4.114 K4 14.82 0.0747 0.0 29.000 2.167 Vel = 5.50 0.0 14.82 13.281 KFactor= 4.07 H4 14.82 1.049 EqI 24.0 5.000 7.000 K Factor= 5.60 to 120.0 0.0 24.000 4,114 K5 14.82 0.0747 0.0 29.000 2.167 Vel = 5.50 0.0 14.82 13.281 KFactor 4.07 H5 14.82 1.049 EqI 24.0 5.000 7.000 K Factor = 5.60 to 120.0 0.0 24.000 4.114 K6 14.82 0.0747 0.029.000 2.167 Vel =5.50 0.0 14.82 13.281 KFactor=4.07 H6 14.82 1.049 EqI 24.0 5.000 7.000 K Factor = 5.60 to 120.0 0.0 24.000 4.114 K7 14.820:0747 0.029.000 2.167 Vel _5.50 0.0 14.82 13.281_KFactor _4.07 1 16.17 1.049 E 2.0 6.030 15.816 K Factor @ node K6 to 120.0 T 5.0 7.000 -0.282 2 16.17 0.0879 0.0 13.030 1.145 Vel = 6.00 2 16.29 2.157 0.0 4.420 16.679 to 120.0 0.0 0.0 0.0 3 32.460.0095 0.04.420 --0.042 Vel =2.85 3 16.19 2.157 0.0 6.000 16.721 to 120.0 0.0 0.0 0.0 4 48.65 0.0202 0.0 6.000 0.121 Vel = 4.27 4 16.68 2.157 0.0 3.610 16.842 to 120.0 0.0 0.0 0.0 5 65.33 0.0346 0.0 3.610 0.125 Vel = 5.74 5 16.40 2.157 2T 24.613 13.170 16.967 to 120.0 0.0 24.613 -0.117 6 81.73 0.0526 0.0 37.783 1.986 Vel = 7.18 6 17.21 2.157 0.0 13.260 18.836 to 120.0 0.0 0.0 0.0 7 98.94 0.0749 0.0 13.260 0.993 Vel = 8.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 7 17-055 BLDG 5823 NEWTON PHASE I Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 7 19.20 2.157 0.0 4.170 19.829 to 120.0 0.0 0.0 0.0 8 118.14 0.1038 0.0 4.170 0.433 Vel = 10.37 8 19.40 2.157 0.0 16.160 20.262 to 120.0 0.0 0.0 0.0 9 137.54 0.1377 0.0 16.160 2.226 Vel = 12.08 9 20.42 2.157 0.0 4.220 22.488 to 1200 0.0 0.0 0.0 10 157.96 0.1777 0.0 4.220 0.750 Vel = 13.87 10 20.74 2.157 0.0 14.560 23.238 to 120.0 0.0 0.0 0.0 11 178.7 0.2235 0.0 14.560 3.254 Vel = 15.69 11 83.69 2.157 T 12.307 3.490 26.492 to 120.0 0.0 12.307 -0.043 12 262.39 0.4548 0.0 15.797 7.185 Vel = 23.04 - 12 24.27 2.157 3E 18.46 27.010 33.634 to 120.0 T 12.307 30.767 -10.238 13 286.66 0.5357 0.0 57.777 -30.950 Vel = 25.17 - 13 -96.18 2.635 T 16.474 16.840 54.346 to 120.0 0.0 16.474 0.0 14 190.48 0.0949 0.0 33.314 3.161 Vel = 11.21 14 0.0 2.635 T 16.474 5.990 57.507 to 120.0 0.0 16.474 2.594 15 190.48 0.0949 0.0 22.464 2.132 Vel = 11.21 15 0.0 6.357 0.0 11.000 62.233 to 120.0 0.0 0.0 0.0 16 190.48 0.0013 0.0 11.000 0.014 VeI= 1.93 16 4.94 6.357 0.0 11.900 62.247 to 120.0 0.0 0.0 0.0 17 195.42 0.0014 0.0 11.000 0.015 Vel= 1.98 17 5.94 6.357 0.0 11.000 62.262 to 120.0 0.0 0.0 0.0 18 201.36 0.0015 0.0 11.000 0.016 Vel = 2.04 18 6.88 6.357 0.0 11.000 62.278 to 120.0 0.0 0.0 0.0 19 208.24 0.0015 0.0 11.000 0.017 Vel = 2.10 19 7.85 6.357 0.0 11.000 62.295 to 120.0 0.0 0.0 0.0 20 216.09 0.0016 0.0 11.000 0.018 Vel = 2.18 20 8.81 6.357 0.0 11.000 62.313 to 120.0 0.0 0.0 0.0 21 224.9 0.0018 0.0 11.000 0.020 Vel = 2.27 21 . 9.93 6.357 0.0 11.000 62.333 to 120.0 0.0 0.0 0.0 22 234.83 0.0019 0.0 11.000 0.021 Vel= 2.37 22 11.07 6.357 0.0 11.000 62.354 to 120.0 0.0 0.0 0.0 23 245.9 0.0021 0.0 11.000 0.023 Vel = 2.49 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams iltennium Fire Protection Page 8 17-055 BLDG 5823 NEWTON PHASE I Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 23 11.16 6.357 0.0 11.000 62.377 to 120.0 0.0 0.0 0.0 24 257.06 0.0023 0.0 11.000 0.025 Vet = 2.60 24 13.97 6.357 0.0 11.000 62.402 to 120.0 0.0 0.0 0.0 25 271.03 0.0025 0.0 11.000 0.027 Vet = 2.74 25 15.63 6.357 2E 35.205 34.080 62.429 to 120.0 0.0 35.205 0.0 TASR 286.66 0.0028 0.0 69.285 0.192 Vel = 2.90 TASR 0.0 8.249 E 21.141 32.670 62.621 to 120.0 B 14.094 93.960 14.149 BASE 286.66 0.0008 - Avc 58.725 126.630 0.099 Vet = 1.72 BASE 0.0 8.27 9E 256.212 600.000 76.869 to 140.0 Zac 0.0 256.212 4.305 * * Fixed Loss = 6.037 TEST 286.66 0.0006 0.0 856.212 0.496 Vet = 1.71 100.00 Qa = 100.00 386.66 - 81.670 K Factor= 42.79 26 16,19 1.049 E 2.0 6.030 15.856 K Factor @ node K6 to 120.0 T 5.0 7.000 -0.282 3 - 16.19 0.0880 0.0 13.030 1.147 Vet = 6.01 0.0 16.19 16.721 KFactor 3.96 27 16.29 1.049 2E 4.0 6.030 16.052 K Factor @ node K6 to 120.0 0.0 4.000 -0.282 28 16.29 0.0890 0.0 10.030 0.893 Vet = 6.05 28 0.0 2.157 0.0 6.000 16.663 to 120.0 0.0 0.0 0.0 216.290.0027 0.06.000 0.016 Vet=1.43 0.0 16.29 16.679 K Factor =3.99 - 29 16.40 1.049 2E 4.0 4.920 16.263 K Factor @ node K4 to 120.0 0.0 4.000 -0.100 5 16.4 01 0901 0.0 8.920 0.804 Vet=6.09 0.0 16.40 16.967 K Factor = 3.98 30 16.68 1.049 E 2.0 0.490 16.842 K Factor @ node K6 to 120.0 0.0 2.000 -0.212 31 16.68 0.0932 0.0 2.490 0.232 Vet = 6.19 31 0.0 2.157 T 12.307 5.540 16.862 to 120.0 0.0 12.307 -0.069 4 16.68 0.0027 0.0 17.847 0.049 Vet = 1.46 0.0 16.68 16.842 K Factor= 4.06 32 17.21 1.049 E 2.0 3.320 17.927 K Factor © node K4 to 120.0 T 5.0 7.000 -0.108 6 17.21 0.0985 0.0 10.320 1.017 Vet = 6.39 0.0 17.21 18.836 KFactor= 3.97 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 9 17-055 BLDG 5823 NEWTON PHASE I Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "Cl' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 33 19.20 1.049 E 2.0 1.910 19.369 K Factor @ node K2 to 120.0 T 5.0 7.000 -0.615 7 19.2 0.1207 0.0 8.910 1.075 Vel = 7.13 0.0 19.20 19.829 KFactor= 4.31 34 19.40 1.049 E 2.0 1.910 19.781 K Factor @ node K2 to 120.0 T 5.0 7.000 -0.615 8 19.4 0.1230 0.0 8.910 1.096 Vel = 7.20 0.0 19.40 - -20.262 KFactor= 4.31 - 35 20.42 1.049 E 2.0 1.910 21.898 K Factor @ node K2 to 120.0 T 5.0 7.000 -0.615 9 20.42 0.1352 0.0 8.910 1.205 Vel = 7.58 0.0 20.42 22.488 K Factor 4.31 36 20.75 1.049 E 2.0 1.910 22.612 K Factor @ node K2 to 120.0 T 5.0 7.000. .0.615 10 20.75 0.1393 0.0 8.910 1.241 Vel = 7.70 0.0 20.75 23.238 Factor = 4.30 -K 37 19.84 1.049 2E 4.0 4.540 23.824 K Factor@ node K7 to 120.0 T 5.0 9.000 -0.368 38 19.84 0.1283 0.0 13.540 1.737 Vel = 7.37 38 42.75 2.157 0.0 9.130 25.193 to 120.0 0.0 0.0 -0.113 39 62.59 0.0321 0.0 9.130 0.293 Vel = 5.50 39 21.09 2.157 T 12.307 10.520 25.373 to 120.0 0.0 12.307 -0.134 11 83.68 0.0549 0.0 22.827 1.253 -- Vel = 7.35 0.0 83.68 26.492 K Factor= 16.26 40 21.38 1.049 E 2.0 2.250 24.008 K Factor @ node K2 to 120.0 T 5.0 7.000 -0.108 41 21.380.1471 0.0 9.250 1.361 Vel=7.94 41 0.0 2.157 0.0 12.010 25.261 to 120.0 0.0 0.0 -0.152 42 21.380.0044 0.0 - 12.010 0.053 Vel=1.88 42 21.37 2.157 0.0 10.130 25.162 to 120.0 0.0 0.0 -0.130 38 42.75 0.0159 0.0 10.130 0.161 Vel = 3.75 0.0 42.75 25.193 KFactor = 8.52 43 21.37 1.049 E 2.0 2.550 23.995 K Factor @ node K2 to 120.0 T 5.0 7.000 -0.238 42 21.37 0.1471 0.0 9.550 1.405 Vel = 7.93 0.0 21.37 25.162 KFactor 4.26 44 21.09 1.049 T 5.0 1.110 24.976 K Factor @ node K3 to 120.0 0.0 5.000 -0.481 39 21.09 0.1437 0.0 6.110 0.878 Vel = 7.83 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Eø Millennium Fire Protection Page 10 17-055 BLDG 5823 NEWTON PHASE I Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "s" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 21.09 . 25.373 KFactor= 4.19 45 24.27 1.049 1 5.0 1.520 33.078 K Factor @ node K3 to 120.0 0.0 5.000 -0.658 12 24.27 0.1862 0.0 6.520 1.214 Vel = 9.01 0.0 24.27 -- 33.634 K Factor = 4.18 16 -4.95 2.469 T 12.0 5.680 62.247 to 120.0 0.0 12.000 -2.460 46 -4.95 -0.0002 0.0 17.680 - -0.003 Vel = 0.33 46 0.0 2.469 2T 24.0 130.180 59.784 to 120.0 0.0 24.000 0.0 47 -4.95 -0.0001 0.0 154.180 -0.023 Vel = 0.33 47 0.0 2.469 T 12.0 5.680 59.761 to. 120.0 0.0 12.000 2.460 48 -4.95 -0.0002 0.0 17.680-0.003 Vel=0.33 48 96.18 6.357 0.0 11.000 62.218 to 120.0 0.0 0.0 0.0 49 91.23 0.0004 0.0 11.000 0.004 Vel = 0.92 49 -5.93 6.357 0.0 11.000 62.222 to 120.0 0.0 0.0 0.0 50 85.3 0.0003 0.0 11.000 0.003 Vel = 0.86 50 -6.89 6.357 0.0 11.000 62.225 to 120.0 0.0 0.0 0.0 51 78.410.0003 0.011.000 0.003 Vel=0.79 51 -7.84 6.357 0.0 11.000 62.228 to 120.0 0.0 0.0 0.0 52 70.57 0.0002 0.011.000 0.002 Vel=0.71 52 -8.82 6.357 2E 35.205 31.700 62.230 to 120.0 0.0 35.205 0.0 53 61.750.0002 0.066.905 0.011 Vel _0.62 53 -9.93 6.357 0.0 11.000 62.241 to 120.0 0.0 0.0 0.0 54 51.820.0001 0.01.1.000 0.001 Vel = 0.52 _- 54 -11.06 6.357 0.0 11.000 62.242 to 120.0 0.0 0.0 0.0 55 40.760.0001 _0.011.000 0.001 Vel _0.41 55 -11.16 6.357 2E 35.205 24.570 62.243 to 120.0 0.0 35.205 0.0 56 29.6 0.0001 0.0 59.775 0.003 Vel = 0.30 56 -13.97 6.357 0.0 11.000 62.246 to 120.0 0.0 0.0 0.0 57 15.63 0.0 0.0 11.000 0.0 Vel = 0.16 57 0.0 2.469 T 12.0 2.780 62.246 to 120.0 0.0 12.000 -1.204 58 15.63 0.0013 0.0 14.780 0.019 Vel = 1.05 58 0.0 2.469 E 6.0 95.910 61.061 to 120.0 T 12.0 18.000 0.0 59 15.63 0.0013 0.0 113.910 0.145 Vel = 1.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 11 17-055 BLDG 5823 NEWTON PHASE I Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 59 0.0 2.469 T 12.0 2.780 61.206 to 120.0 0.0 12.000 1.204 25 15.63 0.0013 0.0 14.780 0.019 Vet = 1.05 0.0 15.63 62.429 KFactor = 1.98 48 -96.18 6.357 0.0 11.000 62.218 to 120.0 0.0 0.0 0.0 60 -96.18 -0.0004 0.0 11.000, -0.004 Vel = 0.97 60 0.0 2.469 T 12.0 5.990 62.214 to 120.0 0.0 12.000 -2.594 61 -96.18 -0.0368 0.0 17.990 -0.662 Vet = 6.45 61 0.0 2.469 T 12.0 113.340 58.958 to 120.0 0.0 12.000 0.0 13 -96.18 -0.0368 00 125.340 -4.612 Vet = 6.45 0.0 -96.18 54.346 K Factor = -13.05 49 5.93 2.469 T 12.0 5.360 62.222 to 120.0 0.0 12.000 -2.321 62 5.93 0.0002 0.0 17.360 0.003 Vet = 0.40 62 0.0 2.469 2T 24.0 130.180 59.904 to 120.0 0.0 24.000 0.0 63 5.93 0.0002 0.0 154.180 0.033 Vet = 0.40 63 0.0 2.469 T 12.0 5.360 59.937 to 120.0 0.0 12.000 2.321 17 5.93 0.0002 0.0 17.360 0.004 Vet = 0.40 0.0 5.93 62.262 K Factor = 0.75 50 6.89 2.469 T 12.0 5.040 62.225 to 120.0 0.0 12.000 -2.178 64 6.89 0.0003 0.0 17.040 0.005 Vet = 0.46 64 0.0 2.469 2T 24.0 130.180 60.052 to 120.0 0.0 24.000 0.0 65 6.89 0.0003 0.0 154.180 0.043 Vet = 0.46 65 0.0 2.469 T 12.0 5.040 60.095 to 120.0 0.0 12.000 2.178 18 6.89 0.0003 0.0 17.040 0.005 Vet = 0.46 0.0 6.89 62.278 K Factor = 0.87 51 7.84 2.469 T 12.0 4.720 62.228 to 120.0 0.0 12.000 -2.040 66 7.84 0.0004 0.0 16.720 0.006 Vet = 0.53 66 0.0 2.469 2T 24.0 130.180 60.194 to 120.0 0.0 24.000 0:0 67 7.84 0.0004 0.0 154.180 0.055 Vet = 0.53 67 0.0 2.469 T 12.0 4.720 60.249 to 120.0 0.0 12.000 2.040 19 7.84 0.0004 0.0 16.720. 0.006 Vet = 0.53 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 12 '17-055 BLDG 5823 NEWTON PHASE I Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 7.84 62.295 K Factor= 0.99 52 8.81 2.469 T 12.0 4.390 62.230 to 120.0 0.0 12.000 -1.901 68 8.81 0.0004 0.0 16.390 0.007 Vel = 0.59 68 0.0 2.469 2T 24.0 130.180 60.336 to 120.0 0.0 24.000 0.0 69 8.81 0.0004 - 0.0 154.180 -- 0.068 Vel=0.59 69 0.0 2.469 T 12.0 4.390 60.404 to 120.0 0.0 12.000 1.901 20 8.810.0005 0.0 _16.390 0.008 Vel=0.59 0.0 8.81 62.313 K Factor = 1.12. 53 9.93 2.469 T 12.0 4.070 62.241 to 120.0 0.0 12.000 -1.763 70 9.93 0.0006 0.0 16.070 0.009 Vel = 0.67 70 0.0 2.469 2T 24.0 109.480 60.487 to 120.0 0.0 24.000 0.0 71 9.93 0.0006 0.0 133.480 0.074 Vel =0.67 71 0.0 2.469 T 12.0 4.070 60.561 to 120.0 0.0 12.000 1.763 21 9.93 0.0006 0.0 16.070 0.009 Vel = 0.67 0.0 9.93 62.333 KFactor 1.26 54 11.06 2.469 T 12.0 3.750 62.242 to 120.0 0.0 12.000 -1.620 72 11.06 0.0007 0.0 15.750 0.011 Vel = 0.74 72 0.0 2.469 2T 24.0 109.480 60.633 to 120.0 0.0 24.000 0.0 73 -11.060.0007 0.0133.480 0.090 Vel =0.74 - 73 0.0 2.469 T 12.0 3.750 60.723 to 120.0 0.0 12.000 1.620 22 11.06 0.0007 0.0 15.750 0.011 Vel = 0.74 0.0 11.06 - 62.354 KFactor 1.40 55 11.16 2.469 1 12.0 3.430 62.243 to 120.0 0.0 12.000 -1.481 74 11.16 0.0007 0.0 15.430 -0.011 Vel = 0.75 74 0.0 1.61 E 4.0 1.480 60.773 to 120.0 0.0 4.000 0.0 75 11.16 0.0055 0.0 5.480 0.030 Vel = 1.76 75 0.0 2.469 T 12.0 108.000 60.803 to 120.0 0.0 12.000 0.0 76 11.16 0.0007 0.0 120.000 0.082 Vel = 0.75 76 0.0 2.469 T 12.0 3.430 60.885 to 120.0 0.0 12.000 1.481 23 11.16 0.0007 0.0 15.430 0.011 Vel = 0.75 0.0 11.16 62.377 KFactor= 1.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams .- Millennium Fire Protection Page 13 17-055 BLDG 5823 NEWTON PHASE I Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 56 13.97 2.469 T 12.0 3.100 62.246 to 120.0 0.0 12.000 -1.343 77 13.97 0.0011 0.0 15.100 0.016 Vel 0.94 77 0.0 2.469 2T 24.0 95.910 60.919 to 120.0 0.0 24.000 0.0 78 13.97 0.0010 0.0 119.910 0.124 Vel = 0.94 78 0.0 2.469 1 12.0 3.100 61.043 to 120.0 0.0 12.000 1.343 24 13.97 0.0011 0.0 15.100 0.016 Vel 0.94 0.0 13.97 62.402 K Factor = 1.77 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CORP. Material Submittal Therino Fisher Bldg 5823 - Phase 1 Tenant Improvement Table of Contents HYDRAULIC CALCULATIONS THERMO FISHER BLDG 5823 PHASE I Millennium Fire Protection 2950 San Luis Rey Road Oceanside, CA 92058 (760) 722-2722 Job Name 17-055 BLDG 5823 NEWTON PHASE 1 Building : FP-004 Location 5823 NEWTON DRIVE, CARLSBAD, CA 92008 Remote Area I Contract : 17-055 Data File : 17-055 BLDG 5823 NEWTON PHASE I Area I - New.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Millennium Fire Protection Page 1 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 HYDRAULIC CALCULATIONS for Project name: 17-055 BLDG 5823 THERMO FISHER PHASE I Location: 5823 NEWTON DRIVE, CARLSBAD, CA 92008 Drawing no: FP-004 Date: 11/07/2017 Design Remote area number: I Remote area location: HYDRAULICALLY MOST DEMANDING Occupancy classification: B, S-I Density: 0.10 - Gpm/SqFt Area of application: 1507-SqFt Coverage per sprinkler: 192 - SqFt Type of sprinklers calculated: STANDARD QUICK RESPONSE No. of sprinklers calculated: 13 In-rack demand: - GPM Hose streams: 100 -GPM Total water required (including hose streams): 386.59 - GPM @ 87.24 - Psi Type of system: STANDARD - WET Volume of dry or preaction system: -Gal Water supply information Date: Location: 5823 NEWTON DRIVE Source: CITY OF CARLSBAD Name of contractor: Millennium Fire Protection Address: 2950 San Luis Rey Road / / Oceanside, CA 92058 Phone number: (760) 722-2722 Name of designer: BRYANT ARIAS Authority having jurisdiction: CITY OF CARLSBAD FIRE DEPARTMENT Notes: (Include peaking information or gridded systems here.) 10% ALLOWANCE INCLUDED IN CALC Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Millennium Fire Protection Page 2 17-055 BLDG 5823 NEWTON PHASE 1 Date 1/26/2018 City Water Supply: Demand: Cl - Static Pressure : 105 Dl - Elevation : 4.114 C2 - Residual Pressure: 78.4 D2 - System Flow : 286.593 C2 - Residual Flow : 1663.1 D2 - System Pressure : 87.236 Hose ( Demand) :100 D3 - System Demand : 386.593 Safety Margin : 15.975 150 140 130 p120 R° E 100 - - )2 - 90 I S 80 U 70 R6° E5° 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Millennium Fire Protection . Page 3 17-055 BLDG 5823 NEWTON PHASE 1 - Date 1/26/2018 Fitting Legend Abbrev. Name % 1% 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 Ave Alarm Vic 75 U 0 0 J 3 9 5 17 0 21 0 22 50 0 0 0 0 0 0 0 B NFPA 13 Butterfly Valve 2 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 iO 12 14 18 22 27 35 40 45 50 61 I NFPA139O' Flow thruTee 3 4 5 6 8 10 12. 15 17 20 25 30 35 50 60 71 81 91 101 121 Zac Ames 2000SS Fitting generates a Fixed LO5 based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons pe Minute Pressure Units Pounds Per Square rch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 'MTdham N.H. USA )3087 Pressure / Flow Summary - STANDARD Millennium Fire Protection Page 4 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Hi 9.5 5.6 11.76 na 19.2 0.1 192 7.0 H2 9.5 5.6 9.0 na 16.8 0.1 168 7.0 H3 9.5 5.6 7.0 na 14.82 0.1 120 7.0 H4 9.5 5.6 7.0 na 14.82 0.1 100 7.0 H5 9.5 5.6 7.0 na 14.82 0.1 74 7.0 H6 9.5 5.6 7.0 na 14.82 0.1 60 7.0 1 10.0 K= K@ K6 20.95 na 16.64 2 10.65 21.87 na 3 10.65 21.92 na 4 10.65 22.04 na 5 10.65 22.18 na 6 10.92 24.15 na 7 10.92 25.19 na 8 10.92 25.64 na 9 10.92 27.94 na 10 10.92 28.71 na 11 10.92 32.03 na 12 11.02 39.22 na 13 34.66 59.91 na 14 34.66 63.07 na 15 28.67 67.8 na 16 28.67 67.81 na 17 28.67 67.83 na 18 28.67 67.84 na 19 28.67 67.86 na 20 28.67 67.88 na 21 28.67 67.9 na 22 28.67 67.92 na 23 28.67 67.94 na 24 28.67 67.97 na 25 28.67 68.0 na TASR 28.67 68.19 na BASE -4.0 82.44 na TEST 0.0 87.24 na 100.0 26 10.0 K = K @ K6 20.99 na 16.66 27 10.0 K=K@K6 21.2 na 16.74 28 10.65 21.86 na 29 10.42 K=K@K4 21.43 na 16.84 30 10.0 K@ K6 22.03 na 17.07 31 10.49 22.06 na 32 10.67 K = K @ K4 23.2 na 17.52 33 9.5 K = K @ K2 24.73 na 19.2 34 9.5 K= K@ K2 25.16 na 19.37 35 9.5 K = K @ K2 27.37 na 20.2 36 9.5 K= K@ K2 28.11 na 20.47 37 9.5 K = K @ K7 29.42 na 19.73 38 10.35 30.77 na 39 10.61 30.94 na 40 9.45 K = K K2 29.63 na 21.02 41 9.7 30.85 na 42 10.05 30.74 na 43 9.5 K = K @ K2 29.62 na 21.01 44 9.5 K = K @ K3 30.57 na 20.75 45 9.5 K = K @ K3 38.74 na 23.36 46 34.35 65.35 na 47 34.35 65.33 na 48 28.67 67.78 na 49 28.67 67.79 na 50 28.67 67.79 na 51 28.67 67.79 na 52 28.67 67.8 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard Millennium Fire Protection Page 5 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 Node Elevation K-Fact Pt Pn Flow Density Area Press No. . Actual Actual Req. 28.67 67.81 na 28.67 67.81 na 28.67 67.81 na 28.67 67.81 na 28.67 67.81 na 31.45 66.63 na 31.45 66.77 na 28.67 67.78 na 34.66 64.52 na 34.03 65.47 na 34.03 65.5 na 33.7 65.62 na 33.7 65.66 na 33.38 65.76 na 33.38 65.82 na 33.06 65.9 na 33.06 65.97 na 32.74 66.05 na 32.74 66.13 na 32.41 66.2 na 32.41 66.29 na 32.09 66.34 na 32.09 66.37 na 32.09 66.45 na 31.77 66.49 na 31.77 66.61 na The maximum velocity is 25.16 and it occurs in the pipe between nodes 12 and 13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 6 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn HI 19.20 1.049 EqI 69.4 4.000 11.755 KFactor= 5.60 to 120.0 0.0 69.400 4.114 K2 19.2 0.1207 0.0 73.400 8.857 Vel = 7.13 - 0.0 19.20 24.726 KFactor= 3.86 H2 16.80 1.049 EqI 69.4 4.000 9.000 K Factor = 5.60 to 120.0 0.0 69.400 4.114 K3 16.8 0.0943 0.0 73.400 6.919 Vel = 6.24 0.0 - 16.80 20.033 K Factor= 3.75 - H3 14.82 1.049 EqI 69.4 4.000 7,000 K Factor= 5.60 to 120.0 0.0 69.400 4.114 K4 14.820.0747 0.073.400 5.484 Vel =5.50 0.0 -14.82 16.598 K Factor = 3.64 H4 14.82 1.049 EqI 69.4 4.000 7.000 K Factor = 5.60 to 120.0 0.0 69.400 4.114 K5 14.82 0.0747 0.0 73.400 5.484 Vel = 5.50 0.0 14.82 16.598 K Factor = 3.64 H5 14.82 1.049 EqI 69.4 4.000 7.000 K Factor= 5.60 to 120.0 0.0 69.400 4.114 K6 14.82 0.0747 0.0 73.400 5.484 Vel = 5.50 0.0 14.82 16.598 KFactor 3.64 H6 14.82 1.049 EqI 69.4 4.000 7.000 K Factor = 5.60 to 120.0 0.0 69.400 4.114 K7 14.82 0.0747 0.0 73.400 5.484 Vel = 5.50 0.0 14.82 16.598 KFactor= 3.64 1 16.64 1.049 E 2.0 6.030 20.947 K Factor @ node K6 to 120.0 T 5.0 7.000 -0.282 2 16.64 0.0926 0,0 13.030 1.207 Vel = 6.18 2 16.75 2.157 0.0 4.420 21.872 to 120.0 0.0 0.0 0.0 3 33.39 0.0102 0.0 4.420 0.045 Vel = 2.93 3 16.66 2.157 0.0 6.000 21.917 to 120.0 0.0 0.0 0.0 4 50.05 0.0212 0.0 6.000 0.127 Vel = 4.39 4 17.07 2.157 0.0 3.610 22.044 to 120.0 0.0 0.0 0.0 5 67.12 0.0366 0.0 3.610 0.132 Vel = 5.89 5 16.84 2.157 2T 24.613 13.170 22.176 to 120.0 0.0 24.613 -0.117 6 83.96 0.0552 0.0 37.783 2.087 Vel = 7.37 6 17.51 2.157 0.0 13.260 24.146 to 120.0 0.0 0.0 0.0 7 101.47 0.0784 0.0 13.260 1.040 Vel = 8.91 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 7 17-055 BLDG 5823 NEWTON PHASE 1 Date 1/26/2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 7 19.20 2.157 0.0 4.170 25.186 to 120.0 0.0 0.0 0.0 8 120.67 0.1082 0.0 4.170 0.451 Vel = 10.59 8 19.37 2.157 0.0 16.160 25.637 to 120.0 0.0 0.0 0.0 9 140.04 0.1424 0.0 16.160 2.301 Vel = 12.30 9 20.20 2.157 0.0 4.220 27.938 to 120.0 0.0 0.0 0.0 10 160.24 0.1827 0.0 4.220 0.771 Vel = 14.07 10 20.48 2.157 0.0 14.560 28.709 to 120.0 0.0 0.0 0.0 11 180.72 0.2282 0.0 14.560 3.322 Vel = 15.87 11 82.51 2.157 T 12.307 3.490 32.031 to 120.0 0.0 12.307 -0.043 12 263.23 0.4575 0.0 15.797 7.227 Vel = 23.11 12 23.36 2.157 3E 18.46 27.010 39.215 to 120.0 T 12.307 30.767 -10.238 13 286.59 0.5355 0.0 57.777 30.938 - Vel = 25.16 - 13 -96.15 2.635 T 16.474 16.840 59.915 to 120.0 0.0 16.474 0.0 14 190.44 0.0948 0.0 33.314 3.159 Vel = 11.20 14 0.0 2.635 T 16.474 5.990 63.074 to 120.0 0.0 16.474 2.594 15 190.440.0949 0.022.464 2.131 Vel=11.20 15 0.0 6.357 0.0 11.000 67.799 to 120.0 0.0 0.0 0.0 16 190.44 0.0013 0.0 11.000 0.014 Vel = 1.93 16 4.94 6.357 0.0 11.000 67.813 to 120.0 0.0 0.0 0.0 17 195.380.0014 0.011.000 P.015_• Vel =1.97 17 5.93 6.357 0.0 11.000 67.828 to 120.0 0.0 0.0 0.0 18 201.31 0.0015 0.0 11.000 0.016 Vel= 2.03 18 6.89 6.357 0.0 11.000 67.844 to 120.0 0.0 0.0 0.0 19 208.2 - 0.0015 0.0 11.000 0.017 Vel= 2,10 19 7.84 6.357 0.0 11.000 67.861 to 120.0 0.0 0.0 0.0 20 216.04 0.0016 0.0 11.000 0.018 Vel= 2.18 - 20 8.81 6.357 0.0 11.000 67.879 to 120.0 0.0 0.0 0.0 21 224.85 0.0018 0.0 11.000 0.020 Vel= 2.27 21 9.93 6.357 0.0 11.000 67.899 to 120.0 0.0 0.0 0.0 22 234.78 0.0019 0.0 11.000 0.021 Vel= 2.37 22 11.06 6.357 0.0 11.000 67.920 to 120.0 0.0 0.0 0.0 23 245.84 0.0021 0.0 11.000 0.023 Vel = 2.49 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 8 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 23 11.16 6.357 0.0 11.000 67.943 to 120.0 0.0 0.0 0.0 24 257.0 0.0023 0.0 11.000 0.025 Vel = 2.60 24 13.97 6.357 0.0 11.000 67.968 to 120.0 0.0 0.0 0.0 25 270.97 0.0025 0.0 11.000 0.027 Vel = 2.74 25 15.62 6.357 2E 35.205 34.080 67.995 to 120.0 0.0 35.205 0.0 TASR 286.59 0.0028 0.0 69.285 0.192 Vel = 2.90 TASR 0.0 8.249 E 21.141 32.670 68.187 to 120.0 B 14.094 93.960 14.149 BASE 286.59 0.0008 Avc 58.725 126.630 0.099 Vel = 1.72 BASE 0.0 8.27 9E 256.212 600.000 82.435 to 140.0 Zac 0.0 256.212 4.305 * * Fixed Loss 6.037 TEST 286.59 0.0006 -- 0.0 856.212 0.496 Vel = 1.71 100.00 Qa= 100.00 386.59 _-87.236 __K Factor= 41.39 26 16.66 1.049 E 2.0 6.030 20.989 K Factor @ node K6 to 120.0 T 5.0 7.000 -0.282 3 16.66 0.0929 - 0.0 13.030 1.210 Vel = 6.18 0.0 16.66 21.917 KFactor= 3.56 27 16.74 1.049 2E 4.0 6.030 21.198 K Factor @ node K6 to 120.0 0.0 4.000 -0.282 28 16.74 0.0937 - 0.0 10.030 0.940 Vel = 6.21 28 0.0 2.157 0.0 6.000 21.856 to 120.0 0.0 0.0 0.0 216.740.0027 0.06.000 0.016 Vel _1.47 0.0 16.74 21.872 K Factor= 3.58 29 16.84 1.049 2E 4.0 4.920 21.432 K Factor@ node K4 to 120.0 0.0 4.000 -0.100 5 -16.840.0946 __0.08.920 0.844 _Vel =6.25 0.0 16.84 22.176 KFactor= 3.58 30 17.07 1.049 E 2.0 0.490 22.032 K Factor @ node K6 to 120.0 0.0 2.000 -0.212 31 17.07 0.0972 0.0 2.490 0.242 - Vel = 6.34 31 0.0 2.157 T 12.307 5.540 22.062 to 120.0 0.0 12.307 -0.069 4 17.07 0.0029 0.0 17.847 0.051 Vel = 1.50 0.0 17.07 22.044 KFactor= 3.64 32 17.52 1.049 E 2.0 3.320 23.204 K Factor@ node K4 to 120.0 T 5.0 7.000 -0.108 6 17.52 0.1017 0.0 10.320 1.050 Vel = 6.50 0.0 17.52 24.146 KFactor 3.57 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams 'Millennium Fire Protection Page 9 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv, Ln. Total Pf Pn 33 19.20 1.049 E 2.0 1.910 24.726 K Factor@ node K2 to 120.0 T 5.0 7.000 -0.615 7 19.2 0.1207 0.0 8.910 1.075 Vel = 7.13 0.0 19.20 25.186 K Factor = 383 34 19.37 1.049 E 2.0 1.910 25.160 K Factor @ node K2 to 120.0 T 5.0 7.000 0.615 8 19.37 0.1226 -- 0.0 8.910 1.092 Vel = 7.19 0.0 19.37 25.637 KFactor=3.83 35 20.20 1.049 E 2.0 1.910 27.372 K Factor @ node K2 to 120.0 T 5.0 7.000 -0.615 920.20.1325 -0.08.910 -1.181 Vel 7.50 0.0 - 20.20 27.938 KFactor=3.82 36 20.47 1.049 E 2.0 1.910 28.113 K Factor @ node K2 to 120.0 T 5.0 7.000 -0.615 10 20.470.1359 0.08.910 1.211 Vel _7.60 0.0 20.47 28.709 K Factor= 3.82 37 19.73 1.049 2E 4.0 4.540 29.421 K Factor @ node K7 to 120.0 T 5.0 9.000 -0.368 38 19.730.1268 0.013.540 -1.717 Vel =7.32 38 42.03 2.157 0.0 9.130 30.770 to 120.0 0.0 0.0 -0.113 39 61.76 0.0314 0.0 9.130 0.287 Vel = 5.42 39 20.75 2.157 T 12.307 10.520 30.944 to 120.0 0.0 12.307 ..0134 11 82.51 0.0535 0.0 22.827 1.221 Vel = 7.24 0.0 82.51 32.031 KFactor 14.58 40 21.02 1.049 E 2.0 2.250 29 (7134 K Factor @ node K2 to 120.0 T 5.0 7.000 -C.108 41 21.02 0.1426 0.0 9.250 1.319 Vel = 7.80 41 0.0 2.157 0.0 12.010 30.845 to 120.0 0.0 0.0 -0.152 42 21.02 0.0043 0.0 12.010 0.052 Vel = 1.85 42 21.01 2.157 0.0 10.130 30.745 to 120.0 0.0 0.0 -0.130 38 42.03 0.0153 0.0 10.130 0.155 Vel = 3.69 0.0 42.03 30.770 K Factor= 7.58 43 21.01 1.049 E 2.0 2.550 29.621 K Factor @ node K2 to 120.0 T 5.0 7.000 -0.238 42 21.01 0.1426 0.0 9.550 1.362 Vel = 7.80 0.0 21.01 30.745 K Factor = 3.79 44 20.75 1.049 T 5.0 1.110 30.573 K Factor @ node K3 to 120.0 0.0 5.000 -0.481 39 20.75 0.1394 0.0 6.110 0.852 Vel= 7.70 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 10 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 20.75 30.944 K Factor= 3.73 45 23.36 1.049 T 5.0 1.520 38.742 K Factor@ node K3 to 120.0 0.0 5.000 -0.658 12 23.36 0.1735 0.0 6.520 1.131 Vel = 8.67 0.0 23.36 39.215 K Factor = 3.73 16 -4.95 2.469 T 12.0 5.680 67.813 to 120.0 0.0 12.000 -2.460 46 -4.95 -0.0001 0.0 17.680 -0.002 Vel = 0.33 46 0.0 2.469 2T 24.0 130.180 65.351 to 120.0 0.0 24.000 0.0 47 -4.95 -0.0002 0.0 154.180 -0.024 - Vet = 0.33 47 0.0 2.469 T 12.0 5.680 65.327 to 120.0 0.0 12.000 2.460 48 -4.95 -0.0001 0.0 17.680-0.002 Vel = 0.33 48 96.16 6.357 0.0 11.000 67.785 to 120.0 0.0 0.0 0.0 49 91.21 0.0003 0.0 11.000 0.003 Vel __0.92 49 -5.93 6.357 0.0 11.000 67.788 to 120.0 0.0 0.0 0.0 50 85.28 0.0004 0.0 11.000 0.004 Vet = 0.86 50 -6.88 6.357 0.0 11.000 67.792 to 120.0 0.0 0.0 0.0 51 78.40.0002 0.011.000 _0.002 Vel =0.79 51 -7.85 6.357 0.0 11.000 67.794 to 120.0 0.0 0.0 0.0 52 70.55 0.0003 0.0 11.000 0.003 Vel = 0.71 52 -8.811 6.357 2E 35.205 31.700 67.797 to 120.0 0.0 35.205 0.0 53 61.14 0.0002 0.066.905 0.011 Vel _0.62 53 -9.93 6.357 0.0 11.000 67.808 to 120.0 0.0 0.0 0.0 54 51.81 0.0001 0.0 11.000 0.001 Vel =0.52 54 -11.06 6.357 0.0 11.000 67.809 to 120.0 0.0 0.0 0.0 55 40.750.0001 0.011.000 0.001 Vel =0.41 55 -11.15 6.357 2E 35.205 24.570 67.810 to 120.0 0.0 35.205 0.0 56 29.6 0.0 0.0 59.775 0.002 Vet = 0.30 -. 56 -13.97 6.357 0.0 11.000 67.812 to 120.0 0.0 0.0 0.0 57 15.63 0.0 0.0 11.000 0.0 Vet= 0.16 57 0.0 2.469 T 12.0 2.780 67.812 to 120.0 0.0 12.000 -1.204 58 15.63 0.0013 0.0 14.780 0.019 Vel = 1.05 58 0.0 2.469 E 6.0 95.910 66.627 to 120.0 T 12.0 18.000 0.0 59 15.63 0.0013 0.0 113.910 0.145 Vel= 1.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 11 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Fin 59 0.0 2.469 T 12.0 2.780 66.772 to 120.0 0.0 12.000 1.204 25 15.63 0.0013 0.0 14.780 0.019 Vel = 1.05 0.0 15.63 67.995 KFactor = 1.90 48 -96.16 6.357 0.0 11.000 67.785 to 120.0 0.0 0.0 0.0 60 -96.16 -0.0004 0.0 11.000 -0.004 Vel= 0.97 60 0.0 2.469 T 12.0 5.990 67.781 to 120.0 0.0 12.000 -2.594 61 -96.16 -0.0368 0.0 17.990 -0.662 Vel = 6.44 61 0.0 2.469 T 12.0 113.340 64.525 to 120.0 0.0 12.000 0.0 13 -96.16 -0.0368 0.0 125.340 -4.610 Vel = 6.44 0.0 -96.16 59.915 - K Factor = -12.42 49 5.93 2.469 T 12.0 5.360 67.788 to 120.0 0.0 12.000 -2.321 62 5.93 0.0002 0.0 17.360 0.004 Vel = 0.40 62 0.0 2.469 2T 24.0 130.180 65.471 to 120.0 0.0 24.000 0.0 63 5.93 0.0002 0.0 154.180 0.032 Vel = 0.40 63 0.0 2.469 1 12.0 5.360 65.503 to 120.0 0.0 12.000 2.321 17 5.93 0.0002 0.0 17.360 0.004 Vel = 0.40 0.0 5.93 67.828 K Factor = 0.72 50 6.89 2.469 T 12.0 5.040 67.792 to 120.0 0.0 12.000 -2.178 64 6.89 0.0002 0.0 17.040 0.004 Vel = 0.46 64 0.0 2.469 2T 24.0 130.180 65618 to 120.0 0.0 24.000 0.0 65 _6.890.0003 _.0.0154.180 0.043 -Vel =0.46 65 0.0 2.469 T 12.0 5.040 65.661 to 120.0 0.0 12.000 2.178 18 6.89 0.0003 0.0 17.040 0.005 Vel = 0.46 0.0 6.89 67.844 K Factor= 0.84 51 7.84 2.469 T 12.0 4.720 67.794 to 120.0 0.0 12.000 -2.040 66 7.84 0.0004 0.0 16.720 0.006 Vel = 0.53 66 0.0 2.469 2T 24.0 130.180 65.760 to 120.0 0.0 24.000 0.0 67 7.84 0.0004 0.0 154.180 0.055 Vel = 0.53 67 0.0 2.469 T 12.0 4.720 65.815 to 120.0 0.0 12.000 2.040 19 7.84 0.0004 0.0 16.720 0.006 Vel = 0.53 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 12 17-055 BLDG 5823 NEWTON PHASE I . Date 1/26/2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point . Qt Pf/Ft Eqv. Ln. Total Pf Pn - 7.84 67.861 K Factor= 0.95 52 8.81. 2.469 T 12.0 4.390 67.797 to 120.0 0.0 12.000 -1.901 68 8.81 0.0004 0.0 16.390 0.007 Vel = 0.59 68 0.0 2.469 2T 24.0 130.180 65.903 to 120.0 0.0 24.000 0.0 69 8.81 0,0004 0.0 154.180 0.068 Vel = 0.59 69 0.0 2.469 T 12.0 4.390 65.971. to 120.0 0.0 12.000 1.901 20 8.81 0.0004 - 0.0 16.390 0.007 Vel = 0.59 0.0 8.81 67.879 K Factor= 1.07 53 9.93 2.469 T 12.0 4.070 67.808 to 120.0 0.0 12.000 -1.763 70 9.930.0006 0.0 16.070 - 0.009 Vel =0.67 - 70 0.0 2.469 2T 24.0 109.480 66.054 to 120.0 0.0 24.000 0.0 71 9.930.0005 0.0133.480 0.073 Vel =0.67 71 0.0 2.469 T 12.0 4.070 66.127 to 120.0 0.0 12.000 1.763 21 9.93 0.0006 0.0 16.070 0.009 Vel 0.67 0.0 9.93 67.899 K Factor= 1.21 54 11.06 2.469 T 12.0 3.750 67.809 to 120.0 0.0 12.000 . -1.620 72 11.06 0.0007 0.0 15.750 0.011 Vel= 0.74 72 0.0 2.469 2T 24.0 109.480 66.200 to 120.0 0.0 24.000 0.0 73 11.060.0007 0.0133.480 0.089 Vel =0.74 73 0.0 2.469 T 12.0 3.750 66.289 to 120.0 0.0 12.000 1.620 22 11.06 0.0007 0.0 15.750 0.011 Vel =0.74 0.0 11.06 . 67.920 K Factor = 1.34 55 11.15 2.469 T 12.0 3.430 67.810 to 120.0 0.0 12.000 -1.481 74 - 11.150.0006 0.0 -15.430 0.010 Vel =0.75 74 0.0 1.61 E 4.0 1.480 66.339 to 120.0 0.0 4.000 0.0 75 11.15 0.0055 0.0 5.480 0.030 Vel = 1.76 75 0.0 2.469 T 12.0 108.000 66.369 to 120.0 0.0 12.000 0.0 76 11.15 0.0007 0.0 120.000 0.082 Vet = 0.75 76 0.0 2.469 T 12.0 3.430 66.451 to 120.0 0.0 12.000 1.481 23 11.15 0.0007 0.0 15.430 0.011 Vel= 0.75 0.0 11.15 67.943 KFactor= 1.35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Millennium Fire Protection Page 13 17-055 BLDG 5823 NEWTON PHASE I Date 1/26/2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 56 13.97 2.469 T 12.0 3.100 67.812 to 120.0 0.0 12.000 -1.343 77 13.97 0.0011 0.0 15.100 0.016 Vel = 0.94 77 0.0 2.469 2T 24.0 95.910 66.485 to 120.0 0.0 24.000 0.0 78 13.97 0.0010 0.0 119.910 0.124 Vel = 0.94 78 0.0 2.469 T 12.0 3.100 66.609 to 120.0 0.0 12.000 1.343 24 13.97 0.0011 - 0.0 15.100 0.016 Vel. 0.94 0.0 13.97 67.968 KFactor= 1.69 Computer Programs by Hydratec Inc. Route III Windham N.H. USA 03087 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been.through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Schedule 10 Pipe I.t1H 1IIt' I i 4TitJ - T,r 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 1 1/2 1.900 1.682 2.09 lbs/ft 61 2.375 2.157 2.64 lbs/ft 37 a 1/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Tr Schedule 40 Pipe do fl 1 1.315 1.049 - 1.68 lbs/ft 70 1 1/4 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 2 1/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, (N 6 Chesterfield, MO 63017 contact your salesperson C®US . (800) 325-4467 today at (800) 325-4467 or LISTED '-.....- BULL MOOSE TUBE COMPANY FAX: (636) 537-2645 (636) 537-2600 in the USA, ______ www.bullmoosetube.com or from Canada Ac HO company e-mail: sales@builmoosetube.com call (800) 882-4666 <i > APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 7/09 tqCD /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Grinnell Grooved Fire Protection Products Fire Protection Submittal Sheet Listing and Approval Information rLB [vds] QEMO Page 1 of 8 MARCH 2011 TFPI800 : Page 2 of 8 TFPIBOO Figure Nominal Size Inches Nominal Size mm Pipe Schedule Rated Pressure (psi-lJL,ULC,FM; Bar LPCB and VdS) Figure F 705 1'/4,1'/2,2 42.4,48.3,60.3 Sch 5, ID, WST 175 175 175 - - 11/4, 11/2,2,21/2 42.4,48.3,60.3, 73.0 Sch 10, Sch 40 300 300 300 - - 3,4,5,6,8 88.9,114.3,141.3,168.3, 219.1 Sch 10, Sch 40 300 300 300 - - 10,12 273.0,323.9 Sch 10, Sch 40 250 250 250 - - 11/4, 11/2,2,21/2,3 42.4, 48.3,60.3,73.0,88.9 MF 300 300 300 - - 4 114.3 MF - - 300 - - 11/4,11/2,2,21/2,3,4 42.4,48.3,60.3,73.0,88.9,114.3 OF 300 300 300 - - 11/4,11/2,2,21/2,3,4 42.4, 48.3, 60.3, 73.0, 88.9, 114.3 FLF 300 300 - - - 11/2,2,21/2,3,4 48.3, 60.3, 73.0, 88.9,114.3 FF 300 300 300 - - 1,11/4, 11/2,2 33.7,42.4,48.3, 60.3 MLT, EZT 300 300 300 - - 3 88.9 EZ 300 300 300 - - 4 114.3 EZ 250 250 300 - - 6 168.3 EZ 250 250 175 - - V/4, 11/2, 2 42.4,48.3,60.3 BLT, DT, TL, Gall, Gal Flo 300 300 300 - - 11/4,1V2,2 - 42.4,48.3,60.3 GL, MLT, MI, SL,WLS 300 300 - - - 11/4,11/2,2 42.4,48.3,60.3 UE - - 175 - - 76.1,165.1 BS1387 300 300 300 - - 42.4, 48.3, 60.3, 76.1, 88.9, 114.3 BS1387, ISO 4200 - - - 16 20 139.7 BS1387, ISO 4200 - - - 16 - 165.1 BS1387, ISO 4200 - - - - 20 168.3,219.1 lS04200 - - - 16 20 108.0,133.0,159.0 ISO 4200 300 - 300 - - 216.3 JIS G3452 300 - 300 - - O Figure 707 1'/2,2,2V2 48.3,60.3,73.0 Sch 5, UE,WST 175 175 175 - - 11/2,2,21/2,3,4,5 48.3, 60.3,73.0,88.9,114.3,141.3 Sch 10 450 450 450 - - 6,8,10, 12 168.3, 219.1,273.0, 323.9 Sch 10 450 450 450 - - 11/2,2,21/2,3,4,5 48.3, 60.3,73.0, 88.9, 114.3, 141.3 Sch 40 500 500 500 - 6,8,10, 12 168.3, 219.1, 273.0, 323.9 Sch 40 500 500 500 - - 11/2,2,21/2,3,4 48.3, 60.3,73.0,88.9,114.3 MF, DF, FF, SF, STF 300 300 300 - - 2 60.3 EZT 300 - - - - 3 88.9 EZ 300 300 300 - - 4 114.3 EZ 250 250 300 - - 6 168.3 EZ 250 250 175 - - 11/2, 2, 21/2,3 48.3, 60.3,73.0,88.9 XL 300 300 300 - - 11/2,2 48.3,60.3 GL, MI, MLT, TL 300 300 300 - - 11/2,2 48.3,60.3 Gal 7, Gal Flo 300 300 300 - - 11/2,2 - 48.3,60.3 BLI,DT - - 300 - - 14,16 355.6, 406.4 Sch 30 300 1 - - - - 18,20 457.2,508.0 Sch 30 200 - - - - 24 610.0 Sch 20 250 - - - - 76.1,165.1 B51387,1504200 300 - 300 - 20 - 48.3, 60.3, 88.9, 114.3,168.3 BS1387, ISO 4200 - - - - 20 219.1, 273.0,323.9 ISO 4200 - - - 16 20 Q Figure 71 2 60.3 Sch 5, ID, UE, WST 175 175 175 - - 2,21/2,3,4,5 60.3, 73.0, 88.9,114.3,141.3 Sch 10, Sch 40 250 250 250 - 6,8 168.3,219.1 Sch 10, Sch 40 250 250 250 - - 10,12 273.0, 323.9 Sch 40 250 250 250 - - 2 60.3 BLT, DT, EZT, FF, GL, LS 250 250 250 - - 2 60.3 MI, MLT, IL, WLS, XL 250 250 250 - - 2 60.3 Gal 7, Gal Flo 250 250 250 - - 2 60.3 MF, FF - - 250 - - 2,21/2,3,4 60.3,73.0,88.9,114.3 DF, FF, MF, SF 250 250 250 - - 3,4 88.9,114.3 EZ 250 250 250 - - 6 168.3 EZ 250 250 175 - 2,3,4 60.3, 88.9,114.3 SIF 250 250 250 - - 21/2,3 73.0, 88.9 XL 250 250 250 - - Figure 71 PN16 60.3, 76.1, 88.9,114.3,168.3 6S1387, ISO 4200 250 - 250 16 20 139.7 B51387, ISO 4200 250 - 250 16 - 165.1 B51387, ISO 4200 250 - 250 - 20 219.1, 273.0 ISO 4200 250 - 250 - 20 323.9 ISO 4200 250 - 250 - 16 TFPI800 Page 3 of 8 Figure Nominal Size Inches Nominal Size mm Pipe Schedule Rated Pressure (psi-UL,ULC,FM; Bar LPCB and VdS) / Figure 772 Patented 1'/4, 11/2,2 42.4,48.3,60.3 Sch 5, ID, UE, WST 175 175 175 - - 11/4 42.4 Sch 10, Sch 40 300 300 300 - - 1'/2,2,2V2,3,4 48.3,60.3,73.0,88.9,114.3 Sch 1O Sch 40 500 500 500 - - 5,6 141.3,168.3 Sch 10 300 300 1 300 - - 8 219.1 Sch 10 400 400 400 - - 5 141.3 Sch 40 300 300 300 - - 6 168.3 Sch 40 400 400 400 - - 8 219.1 Scli40 450 450 450 - - 10,12 273.0,323.9 Sch 10, Sch 40 250 250 250 - - 11/4,1V2,2,2'/2,3 42.4,48.3,60.3,73.0,88.9 MF 300 300 300 - - 4 114.3 EZ,MF 250 250 300 - - 3 88.9 EZ 300 300 300 - - 6 168.3 EZ 250 250 300 - - 11h 2,21/2,3,4 0 889 1143 - OF SIF - 300 300 300 - 11/4,11/,,2,21/2,3 424 483 603 730 889 FLF 300 300 - - - 4 114.3 FLF 250 250 - - - 11/2,2,21/2,3 48.3,60.3,73.0,88.9, FF 300 300 300 - - 4 114.3 FF 250 250 300 - - 11/4,11/2,2 42.4,48.3,60.3 Ivir, MLT, WIS -EZI, 300 300 300 - - 11/4,11/2,2 42.4,48.3,6 .3 GL, Gal 7, Gal Flo 300 300 300 - 11/2,2 48.3,60.3 BLT, DI 300 300 300 - - 11/2,2 48.3,60.3 IL, XL 300 300 - - - 76.1, 165.1 B51387 300 300 300 - - 42.4,48.3,60.3,76.1,88.9,114.3 851387, ISO 4200 - - - - - 16 20 139.7 BS1387, ISO 4200 - - - 16 165.1 BS1387, ISO 4200 • - - 20 168.3,219.1,273,0,323.9 IS04200 - - 16 20 O Figure 716 2X11/2,21/2X2,3X2 60.3 x 48.3, 73.0 x 60.3, 88.9 x 60.3 - Sth5 175 175 175 - - 3X21/2,42,4x21/2 88.9 x 73.0,114.3 x 60.3,114.3 x 73.0 Sch5 175 175 175 - - 2X1V2,21/2X2,3X2 60.3x48.3,73.0x60,3,88.9x60.3 Sch l0, Sch 40 350 350 350 - - 3x21/2,4x2,4x2'/2 88.9 x 73.0,114.3 x 60.3,114.3 x 73.0 Sch 1O, Sch 40 350 350 350 - - 4x3,5x4 114.3x88,9,141.3,114.3 Sch 1O, Sch 40 350 350 300 - 6x4,6x5 168,3 x 114.3 x 1638.3 x 141.3 Sch lO, Sch 40 350 350 300 - - 8x6 219.1 x 168.3 Sch 40 350 350 300 - 2x11/2,21/2x2,3x2 60.3 x 48.3, 73.0 x 60.3,88.9 x 60.3 DF,EZI, FF, GL, MF 300 300 300 - - 2X1V2,21/2x2,3X2 60,3x48.3,73.0x60.3,88.9x60.3 MT,MLT,SF,STF,IL - 300 300 300 - - 4x2 114.3x60.3 DF,EZT,FF,GL,MF 300 300 300 - - 4x2 114 3x60 3 MT ALI_SF_STF_IL 300 300 300 - - 3X21/2,4X21h,4X3 88,9x73,0,114,3x73.0,114.3x88.9 DF,MF,SF 300 300 300 - - 4X2V2,4X3 114.3 x 73.0,114.3 x 88.9 FF, STF 300 1 300 1 300 - - 5x4,6x4 141,3x114.3,168.3x114.3 DF, FF, SF, SIF 300 300 300 - 3x2,3x21/2 88.9x60.3,88.903.0 EZ 300 300 300 - - 2X1V2 60.3x48.3 Gal 7, Gal Flo 300 300 300 - - 60.3 x 48.3, 73.0 x 60.3,88.9 x 60.3 851387, ISO 4200 300 - 300 16 20 88.9x76.1,114.3x60.3,114.3x76.1 BS1387, ISO 4200 300 - 300 16 20 114.3x88.9 851387, ISO 4200 300 - 300 16 20 168.3 x 114.3,219.1 x 168.3 IS04200 300 - 300 16 20 139.7x114.3 B51387, ISO 4200 300 - 300 16 - 165,1x114.3 B81387, ISO 4200 300 - 300 - 20 f" Figure 40-5@ 11/4, 11/2, 2x '/2,/4,1 42.4,48.3,60,3 x 21.3,26.7,33.7 Sch 5, Sch 10, Sch 40 175 175 175 - - 11/4, 11/2, 2x 1/2,3/4,1 42.4,48.3,60.3 x 21.3,26,7,33.7 BLI, OF, DI, GL, IS,MF 175 175 175 - - 1h, 11/2, 2x V2,3/4,1 42.4,48.3160.3 x 21.3,26.7,33.7 MI, MLI, IL, WLS, XL 175 175 175 - - 11h_1V2_2x '/2_3/4 1 424_483_603 x 213_267_337 Gal 7_GalFlo 175 175 175 - - 11/4,11hx1/2,3/4,1 42.4,48.3 x 21.3,26.7,33.7 EZT 175 175 175 - 1'/2X'/2,3/4,1 48.3x21.3,26.7,33.7 FF 175 175 175 - - 2'/2 X 1/2,3/4,1 73.0 x 21.3,26.7,33.7 Sch 10, Sch 40 175 175 175 - - 2'/2x1/2,3/4,1 73.0x21.3,26.7,33.7 DF,MF,SThXL J JZ._ 1'/2,2X1/2,3/4,1 48.3,60.3x21.3,26.7,33.7 STF 175 175 175 - - Figure 40-5 Straps are UL and ULC Listed and FM Approved with NPT and ISO threaded outlets as specified in the chart. Page 4 of 8 TFPI800 Figure Nominal Size Inches Nominal Size mm Pipe Schedule Rated Pressure (psi-UL, ULC and FM; bar LPCB and VdS) O Figure 730 Threaded* 2x'/2,1/4,1,11/4,11/2 60.3 x 21.3, 26.7, 33.7, 42.4, 48.3 Sch 5 175 175 175 - - 2 X 1/2,3/4,1,11/4,11/2 60.3 x 21.3, 26.7,33.7,42.4,48.3 Sch 10, Sch 40 300 300 300 - - 21/2 X 1/2,3/4,1, 11/4, 11/2,2 73.0 x 21.3, 26.7, 33.7, 42.4, 48.3, 60.3 Sch 10, Sch 40 300 300 300 - - 3,4 x 1/2,3/4,1 88.9,114.3 x 21.3, 26.7, 33.7 Sch 10, Sch 40 300 300 300 - - 4 x 21/2,4 x 3 114.3 x 73.0,4 x 88.9 Sch 10, Sch 40 300 300 300 - - 5 x 2,5 x 21/2 141.3 x 60.3,141.3 x 73.0 Sch 10, Sch 40 300 300 300 - - 6 x 11/2,2, 21/2, 3,4 168.3 x 48.3, 60.3,73.0, 88.9,114.3 Sch 10, Sch 40 300 300 300 - - 2 x 1/2,3/4,1,11/4,11/2 60.3 x 21.3, 26.7,33.7,42.4,48.3 BIT, OT, EZT FF, GL, MF 300 300 300 - - 2 x 1/2, 3/4, 1, 11/4, 11/2 60.3 x 21.3, 26.7, 33.7, 42.4, 48.3 MT, MIT, STF, TL, WLS 300 300 300 - - 2 x 1/2,3/4,1,11/4,11/2 60.3 x 21.3, 26.7,33.7,42.4,48.3 Gal 7, Gal Flo 300 300 300 - - 2 x 1/2, 3/4, 1 60.3 x 21.3, 26.7, 33.7 OF 300 300 300 - - 21/2, 3,4 x 1/2, 3/4, 1 73.0, 88.9, 114.3 x 21.3, 26.7,33.7 OF, FF, MF, STF 300 300 300 - - 2X11/4, 11/2 60.3 x42.4, 48.3 OF 300 300 300 - - 3,4x2 88.9,I14.3x60.3 OF, FF, MF,STF 300 300 300 - - 4x2'/2 114.3x73.0 OF, FF, MF,STF 300 300 300 - - 40 3 1.14.3 x 88.9 FF, MF, STF 300 300 300 - - 76.1 x21.3, 26.7, 33.7 BS1387, ISO 4200 300 - 300 16 20 139.7 x48.3, 88.9 BS1387, ISO 4200 .300 - 300 16 20 165.1 x42.4 BS1387, ISO 4200 300 - 300 16 20 60.3 x 21.3,26.7,33.7,42.4,48.3 BS1387, ISO 4200 - - - 16 20 76.1 x 42.4, 48.3, 60.3 BS1387, ISO 4200 - - - 16 20 88.9 x 21.3, 26.7, 33.7, 42.4, 48.3, 60.3 B51387, ISO 4200 - - - 16 20 114.3 x 21.3, 26.7, 33.7, 42.4 BS1387, ISO 4200 - - - 16 20 114.3 x 48.3, 76.1, 88.9 BS1387, ISO 4200 - - - 16 20 165.1 x 48.3, 60.3, 76.1, 88.9, 114.3 B51387, ISO 4200 - - 20 139.7 x 60.3, 76.1 B51387, ISO 4200 - - - 16 - 168.3 x 48.3, 60.3, 73. 0 ISO 4200 - - - 16 20 168.3, 219.1 x 76.1, 88.9,114.3 ISO 4200 - - - 16 20 O 3,4 Figure 730 Grooved**t 2 x 11/2 60.3 x 48.3 Sch 5 175 175 175 - - 2, 21/2, 3,4,5,6 X 1h 60.3,73.0,88.9,114.3,141.3,168.3 x 48.3 Sch 10, Sch 40 300 300 300 - - 3,4,5 x 2,21/2 88.9,114.3,141.3 x 60.3,73.0 Sch 10, Sch 40 300 300 300 - - 4 x 3,5 x 3 114.3 x 88.9,141.3 x 88.9 Sch 10, Sch 40 300 300 300 - - 6 x 21/2,3,4 168.3 x 48.3, 73.0, 88.9,114.3 Sch 10, Sch 40 250 250 250 - 8x21/2,3,4 219.1 x73.O, 88.9, 114.3 Sch lO, Sch 40 300 300 300 - - 2, 2V2, 3,4 x 1V2 60.3,73.0,88.9, 114.3 x 48.3 OF 300 300 300 - - x 2 88.9,114.3 x 60.3 OF 300 300 300 - - .2 X 11/2 60.3 x 48.3 BLT, TL 300 300 300 3 x 11/2 88.9 x 48.3 EZ 300 300 300 - - 139.7 x 48.3,88.9 8S1387, ISO 4200 300 - 300 16 20 165.1 x 42.4, 48.3, 60.3, 76.1 B51387, ISO 4200 300 - 300 16 20 60.3 x 42.4, 48.3 BS1 387, ISO 4200 - - - 16 20 76.1 x 42.4, 48.3, 60.3 BS1 387, ISO 4200 - - - 16 20 . 88.9 x 42.4, 48.3, 60.3 -- B51387, ISO 4200 - ,- - 16 20 114.3 x 42.4, 48.3, 60.3, 76.1, 88.9 8S1387, ISO 4200 - - 16 20 165.1 x 48.3,60.3,76.1,88.9,114.3 BS1387, ISO 4200 - - - - 20 139.7 x 60.3, 76.1 BS1387, ISO 4200 - - - 16 168.3 x 48.3,60.3,73.0 ISO 4200 - - - 16 20 168.3, 219.1 x 76.1, 88.9,114.3 ISO 4200 - - - 16 * Figure 730 Threaded Mechanical Outlets are UL and ULC Listed and FM Approved in both the Tee and Cross configuration with NPT and ISO threaded outlets as specified in the chart. Figure 730 Grooved Mechanical Outlets are UL and ULC Listed and FM Approved in both the Tee and Cross configuration. I: Figure 730 Threaded and Grooved Mechanical Outlets are VdS Approved in the Tee configuration only. Grinnell® products are UL and ULC Listed and FM, LPCB and VdS Approved, as specified in the charts, for the pressure ratings shown for use in Fire Protection Systems (automatic sprinkler, open sprinkler and standpipe) and connections to such. systems. The charts were developed from the latest Listings and Approval data available at the time of publication. Listings are subject to changes and additions by the approval bodies. For Dry Pipe systems or Freezer Systems, use Tr-Seal Gaskets and petroleum free silicone lubricant. Follow installation instructions provided in the Installation Handbook I1-1-1000. TFPI800 Page 5 of 8 Figure Nominal Size Inches Nominal Size mm Pipe Schedule Rated Pressure " Figure 577 1-1/4,1-1/2,2 42.4, 48.3,60.3 FLF, MF, XL, GL, 10,40, CT, OF, TL, MT, MLT 300WLS, 30 300 - - 2-1/2,3,4 73.0, 88.9,114.3 FLF, MF, OF 300 300 300 - - 2-1/2,3 73.0, 88.9 FF, XL 300 300 300 - - 1-1/4,1-1/2,2, 2-1/2,3,4,6,8 42.4,48.3,60.3, 73.0,88.9,114.3, 168.3, 219.1 10 300 300 300 1-1/4,1-1/2,2, 2-1/2,3,4,6 42.4,48.3,60.3, 73.0,88.9,114.3, 168.3 40 300 300 300 1,1-1/4,1-1/2,2 33.7,42.4,48.3, 60.3 5 175 175 175 - - 3,4,6 88.9,114.3,168.3 EZF 300 300 300 - - 11/4 42.4 EZT 300 300 300 - - 1-1/2,2 48.3,60.3 EZT, FF 300 300 300 1-1/2,2,2-1/2,3,4 48.3, 603, 73.0,88.9,114.3 STF 300 300 300 - - 4 114.3 STF 250 250 250 - - 8 219.1 0.188 in. wall 300 300 300 - - 1 33.7 ____________________________ 10, 40, XL, IL, OF, BLI, DL, DI, MI, WLS, WST, GL, MLT, Err, El, EL, 5, BS1387M, ISO 4200 300 300 300 ___________________ 5 141.3 10 300 300 300 - - 5 141.3 40 300 300 300 - 76.1mm, 165mm BS1387M, ISO 4200 300 300 139.7mm ISO 4200 300 300 1,1-1/4,1-1/2,2,3,4 33.7,42.4,48.3,60.3,88.9,114.3 BS1387M, ISO 4200 - - - - 20 bar 76.1, 165.1 BS1387M, ISO 4200 20 bar 6,8 168.3, 219.1 Iso 4200 - - - 20 bar 1,1-1/4,1-1/2,2,3, 4,6,8 33.7,42.4,48.3, 60.3,88.9,114.3, 168.3,219.1 150 4200 16 bar 76.1,139.7 ISO 4200 16 bar Pipe Schedule Key STF - Steady Flow Listed/Approved steel sprinkler pipe manu- factured by AMS Tube Corp. BLT - Black Light Wall Threadable Listed/Approved steel sprin- kler pipe manufactured by Allied Tube and Conduit. DF - Dyna-Flow Listed/Approved steel sprinkler pipe manufac- tured by Allied Tube and Conduit. DT - Dyna-Thread Listed/Approved steel sprinkler pipe manu- factured by Allied Tube and Conduit. SF - Super-Flow Listed/Approved steel sprinkler pipe manu- factured by Allied Tube and Conduit. XL - Extra Light Weight Listed/Approved steel sprinkler pipe manufactured by Allied Tube and Conduit. UE - Ultra-Eddy Listed/Approved steel sprinkler pipe manufac- tured by Bull Moose Tube Company. TL - TL Listed/Approved steel sprinkler pipe manufactured by Central Grooved Piping Products. LS - Listed/Approved steel sprinkler pipe manufactured by Century Tube Corporation. ID - IDOD Listed/Approved steel sprinkler pipe manufactured by IDOD Systems. GAL-FLO - Listed/Approved steel sprinkler pipe manufactured by IDOD Systems. GAL-7 - Listed/Approved steel sprinkler pipe manufactured by IDOD Systems. EZ - EZ-Flow Listed/Approved steel sprinkler pipe manufac- tured by Northwest Pipe and Casting Company. FLF - Fire Line Flow Listed/Approved steel sprinkler pipe man- ufactured by Western International Forest Products. MF - Mega Flow Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. MLT - Mega Light Listed/Approved steel sprinkler pipe manu- factured by Wheatland Tube Company. MT - Méga Thread Listed/Approved steel sprinkler pipe manu- factured by Wheatland Tube Company. SL - Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. WLS - WLS Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. WST - WST Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. GL - GL Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. EZT - EZ Thread Listed/Approved steel sprinkler pipe manu- factured by Youngstown Tube Company. FF- Fire-Flo Listed/Approved steel sprinkler pipe manufac- tured by Youngstown Tube Company. 5 - Schedule 5 steel sprinkler pipe 10 - Schedule 10 steel sprinkler pipe 20 - Schedule 20 steel sprinkler pipe 30 - Schedule 30 steel sprinkler pipe 40 - Schedule 40 steel sprinkler pipe BS1387m - British Standard Medium Listed/Approved steel sprinkler tube. IS04200 - ISO Standard Listed/Approved steel sprinkler tube. JIS G3452 - Japanese International Standard Note: Cut and roll grooved references are for pipe runs and also grooved outlets. Page 6 of 8 Figure Figure 201 45° Elbow Figure 210 90° Elbow L Figure 219 _________ Tee _________ Figure 260 : End Cap r' _rI 1110 Figure 250 Concentric Reducer TFPI800 Figure Nominal Size Inches Nominal Size mm Rated Pressure (psi-UL,ULC,FM; Bar LPCB and VdS) c!i ADACAP* 11/2 X 112, /4,1 42.4 x 21.3, 26.7, 33.7 300 300 300 - 2 x 1/2, /4,1 48.3 x 21.3, 26.7, 33.7 300 300 300 - - 21/2 X 1/2, 3/4, 1 60.3 x 21.3, 26.7, 33.7 300 300 300 - - Figure 201 1 33.7 500 500 500 - - 11/4, 11/2, 2, 3,4 42.4, 48.3, 60.3, 88.9, 114.3 500 500 500 16 20 6,8 168.3, 219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 12 323.9 450 450 400 16 20 21/2,5 73.0, 141.3 500 500 500 - -. 76.1 500 - 500 16 20 165.1 500 - 500 - 20 139.7 500 - 500 16 - 108.0,133.0,159.0, 216.3 300 - 300 - - Figure 210 1 33.7 500 500 500 - - 11/4,11/2,2,3,4 42.4, 48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3, 219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 12 323.9 450 450 400 16 20 21/2,5 73.0, 141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 139.7 500 - 500 16 108.0,133.0,159.0, 216.3 300 300 - - Figure 219 1 33.7 500 500 500 - 11/4,1V2, 2, 3,4 42.4, 48.3,60.3, 88.9,114.3 500 500 500 16 20 6,8 168.3, 219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 12 323.9 450 450 400 16 20 21/2,5 73.0, 141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 500 - 20 139.7 500 - 500 16 108.0,133.0,159.0, 216.3 300 - 300 - - Figure 260 11/4, 11/2, 2, 3, 4 42.4,48.3,60.3, 88.9, 114.3 - 500 500 500 16 20 6,8 168.3, 219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 12 323.9 450 450 400 16 20 21/2,5 73.0, 141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 139.7 500 - 500 16 - Figure 250 11/2,X1,2X1 48.3 x 33.7, 60.3 x 33.7 500 500 500 16 - 2 x 11/4, 2 X 11/2 60.3 x 42.4, 60.3 x 48.3 500 500 500 16 20 21/2 x 2, 3 x 21/2, 4 x 21/2 73.0 x 60.3, 88.9 x 73.0, 114.3 x 73.0 500 500 500 16 20 4x2,6x2 114.3 x 60.3, 168.3 x 60.3 500 500 500 16 - 3x2,4x3,6x4 88.9 x 60.3,114.3 x 88.9,168.3 x 114.3 500 500 500 16 20 5 X 4,6 X 5 141.3 xl 14.3, 168.3 X 141.3 500 500 500 - 76.1 x 48.3, 76.1 x 60.3 500 500 500 16 20 88.9 x 76.1,114.3 x 76.1 500 500 500 16 20 139.7 x 88.9, 139.7 xli 4.3 500 500 500 16 - 165.1 x 114.3 500 500 500 - 20 168.3 x 76.1, 168.3 x 139.7 500 500 500 16 - 165.1 x 88.9,165.1 x 139.7 500 * ADACAPs are UL and ULC Listed and FM Approved with NPT and ISO threaded outlets. Figure 519 Tee Figure 510DE Drain Elbow - Page 7 of 8 Figure Nominal Size Inches Nominal Size mm Rated Pressure (psi-UL,ULC,FM; Bar LPCB and VdS) Figure 501 11/4,11/2,2,3,4 42.4, 48.3,60.3,88.9,114.3 300 300 300 16 20 6,8 168.3, 219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 510 11/4,1 1/2, 2,3,4 42.4,48.3,60.3, 88.9, 114.3 300 300 300 16 20 6,8 168.3,219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 519 11/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 300 300 300 16 20 6,8 168.3, 219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 2,3,4,6,8 60.3,83.9,114.3,168.3,219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - - 76.1 300 300 300 16 20 139.7 300 300 300 16 165.1 300 300 300 - 20 Figure 2,3,4,6,8 60.3, 88.9,114.3, 168.3, 219.1 300 300 300 16 20 21/2, 5 73.0, 141.3 300 300 300 - - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 2,3,4,6,8 60.3, 88.9,114.3,168.3, 219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 5100E 21/2,3,4,5 73.0, 88.9,114.3,141.3 300 300 300 - - 6,8 168.3, 219.1 300 TFPI800 Figure 501 45° Elbow Figure 510 90° Elbow Figure 501S 45 Elbow fr TFP 1800 Fabricated Fittings Figure Nominal Size Inches Rated Pressure (psi) —kl<E> Figure 391 Groove x Male Threaded Adapter Nipples 1,11/4,11/2 300 300 2,2% 300 300 3,4,5 ____________ 300 300 6,8 300 300 10,12 300 300 Figure 392 Groove x Groove Adapter Nipples 1,1¼,lh/2 300 300 2,2% 300 300 3,4,5 ____________ 300 300 6,8 300 300 10,12 300 300 Figure 393 Groove x Bevel Adapter Nipples 1,11/4,11/2 300 300 2,2% 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 312 22W Elbow 1'h,1½ 300 300. 2,21/2 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 313 11W Elbow 11/4,11/2 300 300 2,21/, 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Page 8 of 8 Figure Nominal Size Inches Rated Pressure (psi) Figure 321 Reducing Tee 1V4,11/2 .300 300 2, 2% 300 300 _________________ 3,4,5 300 300 6,8 300 300 10,12 300 1 300 Figure 327 Cross 1,1Y4,1½ 300 300 2,21/2 300 300 345 300 300 6,8 300 300 10,12 300 300 Figure 341 Groove Flange Adapter 150lbs. . 300 300 2,21/2 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 350 Concentric Groove x Groove Reducer 114,1% 300 300 2,21/2 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to en- ISO sure that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (lH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 Threaded Fittings I Ili ;J I] A 1i a I Majons "I, Tyco Fire Products --- www.tyco-grooved.com CENTRAL 451 North Cannon Avenue, Lansdalé, Pennsylvania 19446 --- USA ________ Customer Service/Sales: Tel: (215) 362-0700/ Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General ID Description See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information Ductile Iron threaded fittings (with the exception of California Tees and Street Elbows) conform to ANSI 1316.3. They are higher in strength and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties making up the fitting. This is accomplished by adding magnesium while the iron is being poured into it final cast shape. This provides an advantage as the fittings are not as susceptible to leaks or cracking and they are also lighter than standard cast iron. Caution: Installers who have not used ductile iron threaded fittings before should be instructed that the fittings are stronger than the pipe and over- tightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fittings. Apply Teflon tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If you are using an automatic make-on machine, please exercise caution in setting your machine to the proper parameters prior to tightening fittings onto the male pipe threads. Technical Data Figures: 811, 812, 813, 814, 815, 816, 817, 818, 820, 825, 827, 830, 719, California Tees, and Street Elbows Sizes: 1/2" - 21/2" Maximum Working Pressure: 800 Series, California Tees, and Street Elbows: 300 psi Figure 719: 250 psi Approvals: UL, and FM Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Manufacture Source: Imported Material: Ductile Iron, conforming to ANSI B16.3 (Note: Figure 719 Plugs are constructed of Cast Iron) Thread: N.P.T. r.1 Installation Apply Teflon Tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. (See caution in first column) fl Ordering Procedure Ordering information: When placing an order, indicate the full product name. Please specify the quantity, figure number and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, though a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. J Care and Maintenance 17 . The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 21-3.0 -2- Size Inches A Inches B Inches Part Number Weight Lbs. Box Oty. 1/2 11/5 /16 86206 0.24 240 3/4 15/ 16 3/4 86205 0.40 120 1 1 V 13/16 86200 0.64 70 11/4 1/4 11/16 86201 0.95 40 11/2 115/16 1/16 86202 1.24 30 2 21/4 11/2 86203 1.74 20 21/3 211/16 1/16 86204 3.28 10 Figure 815 Reducing Tee I Size Inches A Inches B Inches C Inches D Inches E Inãhes F Inches Part Number Wt. Lbs. Box Qty. 3/4x3/4 x1/2 13/16 1/16 11/4 5/ 5/ 11/18 86235 0.46 95 3/4 x3/4x1 1/16 l/is la/s 7/ 7/ 11/16 86755 0.68 65 1xV2x1 11/2 11/8 11/2 13/16 13/16 13/16 86236 0.70 55 1x3/4x1/2 11/4 1/16 1/8 1116 /s 13/16 86756 0.63 80 1x3/4x3/4 1/8 1/16 1/16 11/16 3/4 /s 86757 0.68 65 1x3/4 x1 11/2 1/16 11/2 13/16 7/ 13/16 86237 0.77 .55 lxi x 1/2 11/4 11/4 13/8 /iF,s/is 13/16 86238 0.66 65 lxi x 3/4 1/8 1/8 1/i6 11/16 11/16 7/ 86239 0.73 60 1 X x 11/4 111/16 111/16 19/16 1 1 7/ 86240 0.97 45 1x1x11/2 113/16 113/16 1/s 11/8 li/s 7/ 86241 1.14 35 11/4 x1 xV2 115/16 11/4 1/16 5/ s/16 1 86242 0.81 50 11/4 x1 x3/4 V/is 1/3 15/8 3/4 11/16 1 V1 86243 0.90 50 11/4 x 1 x 1 1 /16 11/2 111/16 7/ 13/16 1 86244 1.03 45 11/4x1 )(11/4 1/4 111/16 1/4 iVis 1 11/16 86245 1.101 40 11/4x1x11/2 1/8 113/16 113/16 13/16 11/8 11/16 86246 1.431 30 1V4x11/4x1/2 1/8 13/8 15/16 11/16 a/is 1 86247 0.87 45 11/4x 11/4x3/4 17/16 17 /16 1/s 3/4 3/4 lVis 86248 0.96 45 11/4x1V4x1 la/is 1/16 111/16 7/ 7/ 1 86249 1.10 40 1114x11/4x1112 l/s 1/8 113/16 113/16 113/16 1 V1 86250 1.50 30 11/4x11/4x2 21/8 21/8 2 1/1s 1/16 11/8 86251 2.00 24 11/2 x1 x1/2 17/ 16 1/16 111/16 11/16 5/ 11/s 86252 0.97 40 11/2 x1x3/4 11/2 1/8 1/4 3/4 11/16 1/6 86253 1.14 40 11/2x lxi 15/s 11/2 113/16 7/ 13/16 li/s 86254 1.14 30 11/2 x1 x11/2 115/16 113/16 115/16 1 Y1 li/s 13/16 86255 1.52 30 11/2x11/4x1/2 17/is 1/16 111/16 11/6 5/ 11/8 86257 1.03 40 1V2xi1/4x3/4 11/2 li/is 1/4 3/4 3/4 13/ 16 86258 1.10 40 11/2x11/4 x1 '1 '/8 1/16 113/16 7/ 7/ 11/8 86259 1.31 30 11/2x11/4x2 23/16 21/8 2 17/ 16 17/ 16 11/4 86260 1.94 20 11/2x'11/2xV2 1/16 1/16 111/16 11/16 11 A6 li/s 86261 1.14 35 11/2xI1/2x3/4 11/2 11/2 1/4 3/4 3/4 13 /16 86262 1.23 35 1V2x1V2x1 1/8 1/8 113/16 7/ 7/ 11/8 86263 1.38 30 1V2xi1bx11/4 113/15 113/16 i/s li/is li/is is/is 86264 1.50 30 11/2x11/2x2 2/16 23/16 2 17/ 16 17/ 16 11/4 86265 2.00 20 2x1x2 21/4 2 21/4 11/2 1/i6 1 11/2 86266 2.18 15 2x11/4x2 21/4 21/8 21/4 11/2 17/16 11/2 86267 2.31 15 201/2x1/2 11/2 li/is 1/8 3/4 11/16 15/16 86268 1.50 30 2x11/2x3/4 15/8 11/2 115/16 1/5 3/4 1/s 86269 1.61 25 2 xl 1/2 xl 1/4 1/8 2 1 7/ 15/16 86270 1.65 20 2x11/2x11/2 21/16 115/16 23/is 1/16 1/16 17/16 86272 2.03 20 2x11/2x2 21/4 23/16 21/4 11/2 1/16 11/2 86273 2.37 15 2x2x1/2 11/2 1½ 1/8 3/4 3/4 is/is 86222 1.50 30 2x2x3/4 15/8 15/8 115/16 7/ 7/ 1/8 86223 1.67 20 2x2x1 1/4 1/4 2 1 1 1/16 86224 11.91120 2 x 2 x 11/4 1/8 17/s 21/8 11/s 11/8 li/is 86225 2.05 20 2x2x11/2 2 2 12/is 11/4 11/4 11/2 86226 2.11 15 2 x 2 x 21/2 2/8 25/8 12/s 1/4 17/8 17/16 86227 3.67 10 2'/2x2x3/4 l/4 15/s 2/is 5/ 7/ l/4 86274 2.22 15 FB-i Figure 812 90° Reducing Elbow Size Inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Qty. 3/4 x 1/2 1/16 1 Y1 5/ 5/ 86342 0.33 160 1 x 1/2 11/4 1/8 /16 13/16 86210 0.44 110 I x /i 1I8 1/16 1 11/16 1 7/ 86211 0.53 90 11/4 XV2 1/16 11/2 5/ 15/16 86212 0.64 75 11/4 x314 1/16 1/8 3/4 11/16 86213 0.75 60 11/4 x1 1/i6 111/16 7/ 1 86214 0.77 55 11/2 X 3/4 11/2 1/4 3/4 1/16 1 86221 0.95 45 11/2 x1 1/s 113/16 7/ 11/6 86215 0.99 40 1112X 11/4 113/16 1I8 11/8 13/ 16 86216 1.14 35 2x 3/4 1/8 115/16 7/ 1/s 86217 1.39 30 2x 1 1/4 21/16 2 1/is 86218 1.58 25 2x 11/2 2 21 3/16 11/4 17/ 16 1 86220 1.67 20 21/2 x 2 2I8 2/s 11/4 117/71 86262 1 3.01 15 Figure 811 900 Elbow Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 1/ 3/ 86780 0.22 250 3/4 1 i/16 86781 0.33 150 I 11/8 1 13/16 86280 0.48 1 90 11/4 1/16 5/ 86281 0.73 50 11/2 17 /16 1i/ 86282 0.93 :T5- 2 111/16 15/16 86283 1.55 18 21/2 115/is 1 1 86782 2.70 12 Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 11/8 9/16 86340 0.33 150 3/4 15/16 3/4 86341 0.50 90 1 11/2 /15 86230 0.85 60 11/4 1/4 11/16 86231 1.30 35 11/2 115/16 1/16 86232 1.63 24 2 21/4 11/2 86233 2.63 12 21/2 211/16 1/16 86234 4.55 8 Figure 813 45° Elbow Figure 814 Tee Figure 719 Cast Iron Plug Figure 816 Reducing Coupling jA Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 3/4 X 1/2 1/4 11/16 86772 0.38 240 1 X 1/2 1/i6 1/2 86228 0.38 200 I x/.s 1/4 1/2 86229 0.53 110 Figure 825 Extension Piece Size Inches A Inches Part Number Weight Lbs. Box Oty. 1/2 x 11/2 11/2 72751 0.20 300 1/2x 2 2 72980 0.27 250 3/4 X 11/2 11/2 72981 0.22 250 3/4 x2 2 72982 1 0.31 200 Figure 817 Cross Size Inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Qty. 1 11/2 11/2 13/16 13/16 86284 0.97 45 11/4 1/4 1/4 1V16 11/16 86285 1.59 25 11/2 115/16 115/16 1I1 1I16 86286 1.89 20 2 21/4 21/4 11/2 11/2 86287 2.93 10 11/4 X 11/4X 1 X 111/16 1/16 1 /& 86289 1.25 30 V/2X 11/2x 1 X 113/16 1/8 11/16 115/16 86322 1.48 24 2 x 2 x x 1 2 1/4 11/4 11/16 86291 2.64 10 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1 x 1/2 11/16 72726 0.22 280 1 x3/4 11/16 72762 0.18 280 11/4 x 1 1/16 72763 0.31 150 11/2 X1 11/4 72757 0.53 100 11/2x11/4 11/4 72764 0.35 100 2x1 1/8 72759 0.75 80 2 x 11/4 1/ 72761 0.69 80 2 1/8 72775 0.62 80 Figure 818 B A Straight Coupling -- Size Inches A Inches B Inches Part Number Wrench Weight Lbs. Box Qty. 1/2 1/8 /16 72779 11/8 0.18 360 3/4 1/s /16 72778 1/8 0.26 200 1 1/ /a 72755 111/16 0.44 110 11/4 2 /16 72754 2 0.54 75 11/2 2/16 3/4 72753 21/4 0.71 60 2 2/8 11/8 72752 2/4 1.15 30 21/2 3 3/4 72758 33/s 2.29 18 L141J If Figure 830 [ I I 1 A Brass Seat Union 1 [11fi i........i. Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 1/8 13/16 86207 0.47 110 3/4 2 15/16 86275 0.66 80 1 2/i 13/16 86276 1.08 50 11/4 21/2 11/16 1 86277 1.54 35 11/2 2/s 1/16 86278 2.03 25 2 31/8 1/8 86279 3.15 18 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 /8 72776 0.15 500 3/4 1 72777 0.22 300 1 1/18 72824 0.33 180 11/4 1/16 72756 0.54 110 11/2 1/a 72822 0.68 80 2 11/2 72823 0.96 45 21/2 1/4 72825 1.80 25 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 15/16 86292 0.10 500 3/4 11/8 86293 0.18 300 1 11/4 86294 0.28 200 11/4 1/a 86295 0.50 110 11/2 1/1 86296 0.70 80 2 1 11/2 1 86297 0.90 45 Figure 820 Cap PU -3- Street Elbows LE E Size Inches A Inches B Inches C Inches Part Number Weight lbs. Box Qty. 1 X 1/2 11/2 3/4 3 42003 0.70 80 1 X 1 11/2 3/4 3 42002 0.90 60 California Tees Size Inches A Inches B Inches C Inches D Inches Part Number Weight lbs. Box Qty. 1 X 1/2 X 1 11/2 /8 3 3/4 42000 0.95 50 1 x 1 x 1 11/2 3/4 3 3/4 42001 0.95 45 NILimited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. tqco/Flow Control1' Tyco Fire Products -4- Printed U.S.A. 10-01 "THE INCH" QUICK RESPONSE A UTOMA TIC SPRINKLER MODEL GL5606 ONE INCH ADJUSTABLE PLATE CONCEALED PENDENT FLAT DESCRIPTION AND OPERATION The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operations approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards. This sprinkler offers the additional feature of greatly in- creased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate or an optional 2 3/4" diameter ceiling plate color finished to match the specifier's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's GL5606 Concealed Sprinkler utilizes a 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off' designed cover plate is easily installed and with a nominal 1" of adjustment makes it easier to get a proper fit at the ceiling. Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern to extinguish or control the fire. TECHNICAL DATA -See reverse side for Approvals and Specifications. 'Temperature Ratings - 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 35/16" diameter plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate 'Water Working Pressure Rating -175 psi (12 Bars) H: 'Factory tested hydrostatically to 500 psi (34 Bars) -Maximum low temperature glass bulb rating is -67°F 'Frame - bronze • Deflector - brass • Screw - brass 'Lodgement Wire - stainless steel • Bulb seat - copper 23/4" diameter plate -Spring - nickel alloy 'Seal - teflon• Drop Pin - stainless steel QUICK RESPONSE Bulb - glass with alcohol based solution, 3mm size WHITE FLAT PLATE 'Cover Plate - brass Upper Escutcheon Assembly - steel CONCEALED PENDENT NOTE: Globe's wrench P/N 332765 must be used to install this sprinkler. -SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING NOV 2016 GFS-150a (Formerly A-38) "THE INCH" QUICK RESPONSE A UTOMA TIC SPRINKLER MODEL GL5606 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT SPECIFICATIONS NOMINAL THREAD SIZE LENGTH I FLAT COVER "K" FACTOR PLATE FINISHES 5.6 1/2"NPT 2 1/2" I Chrome I (80 metric) (15mm) (6.4cm) White Painted Other Finishes'2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 'FOR PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFCATIONS. APPROVALS STYLE SIN MODEL HAZARD' 135°F (57°C) Flat Cover Plate 155°F (68°C)_FIat Cover Plate cULus *FM NYC-DOB MEA °°135°F (57°C) - 155°F (68°C) **1550F (68°C) 175°F (79°C) 200°F (93°C) Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler 10192-E Adjustable Concealed GL5606 LH/OH X X X X X X X X Pendent 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. *FM APPROVED AS STANDARD RESPONSE **NO FM APPROVALS SECTIONS ROSS OH: ORDINARY HAZARD LH: LIGHT HAZARD F— 21/4" D. rii. —H CEILING OLEIN r,2 1/4"DIA. MIN.HOLEIN CEJUNG 17/8"DIA.- i 7/8" DIA.—H 1"xl/2"-_.JI 1'x1/2" EDUCER IN ) REDUCER -- i1HiIHH'Fri 23/4" MAX. 17/8' MIN. SUPPORT-i - i-,IDE1'LECTOI SUPPORT WFI NI I I DROP PIN SHELL '°'' ---I23/4'1)1* 3/4" DIA. 'jI8_j "" I . 35/16" DIA.--------1 j/8J FLAT COVER PLATE '-FLAT COVER PLATE 1" ADJUSTMENT FLAT PLATE CONCEALED PENDENT FLAT COVER WHITE 135°F (57°C) WHITE 155°F (68°C) [CHROME 135°F (57°C) CHROME 155°F (68°C) PLATE SIZES PART# PART# PART# PART# 2 3/4' DIA. 332726 332731 332724 332729 3 5/16" DIA. 332706 332711 [ 332704 332709 2 3/4" MAX. 17/8' MIN. DROP PIN ORDERING INFORMATION SPECIFY -Quantity Model Number . Style 'Orifice 'Thread Size 'Temperature. Finishes desired 'Quantity - Wrenches - P/N 332765 'Quantity - Protective Caps - P/N 332695 GLk)13E: FIRE SPRINKUR cORPORATION NOV 2016 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com PRINTED U.S.A. GFS-1 50a (Formerly A-38) tqca Fire Protection Products Worldwide I Contacts www.tyco-fire.com Model ESFR-25 252 K-factor Pendent Sprinkler Early Suppression, Fast Response General Description TYCO Model ESFR-25 Pendent Sprin- klers are Early Suppression, Fast Response (ESFR) sprinklers having a nominal K-factor of 25.2 (Ref. Figure 1). They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-25 Sprinklers are pri- marily used for ceiling-only sprinkler protection of (but not limited to) the fol- lowing storage applications: most encapsulated or non-encap- sulated common materials including cartoned, unexpanded plastics uncartoned (exposed) expanded plastics in accordance with NFPA 13 and FM Global standards some storage arrangements of rub- ber tires, roll paper, flammable liq- uids, aerosols, and automotive components For more specific criteria, refer to Table A as well as the applicable design standard. The Model ESFR-25 Pendent Sprin- klers provide the system designer with hydraulic and sprinkler place- ment options not presently available to the traditional ESFR sprinklers having nominal K-factors of 14.0 and 16.8. In particular, the Model ESFR-25 Sprin- kler has been designed to operate at substantially lower-end head pres- sures, as compared to ESFR Sprinklers IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 having nominal K-factors of 14.0 and 16.8. This feature offers flexibility when sizing system piping, as well as possi- bly reducing or eliminating the need for a system fire pump. Also, Model ESFR-25 Sprinklers permit use of a maximum deflector-to-ceiling distance of 18 inches (460 mm) versus 14 inches (356 mm).. Additionally, a storage arrangement of 40 ft. (12,2 m) with a ceiling height of 45 ft. (13,7 m) does not require in-rack sprinklers as do other ESFR Sprinklers having nominal K-factors of 14.0 and 16.8. The Model ESFR-25 Sprinklers are listed by Underwriters Laboratories (UL) for specific applications with a maximum storage height of 43 ft. (13,1 m) with a maximum ceiling height of 48 ft. (14,6 m) without the requirement for in-rack sprinklers. Refer to the Specific Application Listing (UL) for the design criteria. Applications for the TYCO ESFR Sprin- klers are expanding beyond currently recognized installation standards. For information on research fire tests (e.g., with flammable liquids and aerosols) that may be acceptable to an author- ity having jurisdiction, contact Tyco Fire Protection Products (TFPP) Technical Services. The Model ESFR-25 Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any authorities having jurisdiction (e.g., FM Global). Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. In all cases, the appropriate NFPA or FM Global installation standard, or other applicable standard, must be referenced to ensure applicability and to obtain complete installation guide- JULY 2016 lines. The general guidelines in this data sheet are not intended to provide complete installation criteria. Sprinkler Identification Number (SIN) TY9226 TY9226 is a re-designation for Central SIN 9226, Gem SIN G8441, and Star SIN S8010. Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved NYC Approved under MEA 356-01-E LPCB Certified (Cert. Nos. 094b and 0071) CE Certified (Certificate of Conformity 1725-CPD-HOO10) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connections 1 Inch NPT or ISO 7-R 1 Discharge Coefficient K=25.2 gpm/psi½ (362,9 Ipm/bar½) Temperature Ratings 165°F (74°C) and 212°F (100°C) Finish Natural Brass TFP3I2 'rFP312 Page 2 of 4 7 Components: 8 1 - Frame 2 - Deflector 3 - Compression Screw 4 -Hook 6 5 - Strut 6 - Link Assembly 7 - Button 5 8 - Sealing Assembly 9 - Ejection Spring 3 2 I TEMPERATURE I RATING i-.---- 2' (50,8 mm) - FIGURE 1 MODEL ESFR-25 PENDENT SPRINKLER, 25.2K EARLY SUPPRESSION; FAST RESPONSE 3-13/16" (96,8 mm) 9/16" (14,3 mm) NOMINAL MAKE-IN WRENCH FLATS 1NPT 1-13/16' (46,0 mm) \ IF THERMAL SENSING ELEMENT Storage Type NFPA FM Global Open Frame (i.e., no solid shelves) Refer to NFPA 13 Refer to FM Global Single, Double, Multiple-Row, or Portable Rack Storage of Chapters 16 and 17 2-0 and 8-9 Class l-IV and Group A or B Plastics Solid Pile or Palletized Storage of Refer to NFPA 13 Refer to FM Global Class l-IV and Group A or B Plastics Chapters 14 and 15 2-0 and 8-9 Idle Pallet Storage Refer to NFPA 13 Refer to FM Global Chapter 12 2-0, 8-9, and 8-24 Rubber Tire Storage Refer to NFPA 13 Refer to FM Global Chapter 18 2-0 and 8-3 Roll Paper Storage Refer to NFPA 13 Refer to FM Global 8-21 (Refer to the Standard) Chapter 19 Flammable/Ignitable Liquid Storage Refer to NFPA 30 Refer to FM Global 7-29 (Refer to the Standard) Aerosol Storage (Refer to the Standard) Refer to NFPA 30B Refer to FM Global 7-31 Automotive Components in Portable Racks Refer to NFPA 13 N/A (Control mode only; refer to the Standard) Chapter 20 N/A - Not Applicable TABLE A MODEL ESFR-25 PENDENT SPRINKLER COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW TFP3I2 Page 3 of 4 Physical Characteristics Frame .............................Brass Deflector ..........................Bronze Compression Screw ..........Stainless Steel Hook ............................MONEL Strut.............................MONEL Link Assembly................Solder, Nickel Button .............................Brass Sealing Assembly. Beryllium Nickel w/TEFLON Ejection Spring ..................INCONEL Operation The fusible link assembly is com- prised of two link halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, activating the sprinkler and flowing water. Design Criteria The following general guidelines pro vided for the TYCO Model ESFR-25 Pendent Sprinklers can be used for a quick reference. The National Fire Protection Associa- tion (NFPA) and FM Global (FM Approv- als) provide installation standards that must be used to properly design an automatic sprinkler system utilizing Early Suppression, Fast Response (ESFR) Sprinklers. The guidelines pro- vided by NFPA and FM Global may differ. Consequently, the appropri- ate standard must be used for a given installation. In all cases, the appropriate NFPA or FM Global installation standard must be referenced to ensure applicabil- ity and to obtain complete installation guidelines. The following general guidelines are not intended to provide complete installa- tion criteria. In addition to this technical data sheet, the following data sheets describe other TYCO ESFR Sprinklers: TFP315 Model ESFR-17 (TY7226) K=16.8 Pendent Sprinkler TFP316 Model ESFR-17 (TY7126) K=16.8 Upright Sprinkler TFP317 Model ESFR-17 (TY7223) K=16.8 Pendent Sprinkler TFP318 Model ESFR-1 (TY6226) K=14.0 Pendent Sprinkler TFP319 Model ESFR-14 (TY6236) K=14.0 Pendent Sprinkler System Type Wet Pipe Roof Construction Unobstructed or obstructed con- struction (e.g., smooth ceiling, bar joists, beam and girder, and so forth). Where the depths of the solid struc- tural members (e.g., beams and stem) exceed 12 inches (302 mm), install ESFR Sprinklers in each channel formed by the structural members. Ceiling Slope Maximum 2 inch rise for 12 inch run (16.7%) Maximum Coverage Area 100 ft2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Coverage Area 64 ft2 (5,8 m2) per NFPA 13 / FM Global 2-0 Maximum Spacing 12 feet (3,7 m) for building heights up to 30 feet (9,1 m) 10 feet (3,1 m) for building heights greater than 30 feet (9,1 m). In some cases, installation standards permit a greater spacing. Minimum Spacing 8 feet (2,4 m) Minimum Clearance to Commodity 36 inches (914 mm) NFPA Deflector-to-Ceiling Distance 6 to 18 inches (152 to 457 mm) FM Global Centerline of Thermal Sensing Element-to-Ceiling Distance Refer to FM Global 2-0 for Storage Sprinklers. Specific Application Listing (UL) TYCO Model ESFR-25 Pendent Sprin- klers are listed by Underwriters Labo- ratories (UL) for Specific Applications with a ceiling height greater .than 45 ft. (13,7 m) up to and includ- ing 48 ft. (14,6 m), and a storage arrangement up to and including 43 ft. (13,1 m), the following guide- line are provided for the TYCO Model ESFR-25 Pendent Sprinklers: Sprinkler Position Pendent: Frame arms aligned with pipe Deflectors parallel with ceiling or roof System Type Wet Pipe only Maximum Area of Coverage 100 ft2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Area of Coverage 64 ft2 (5,8 m2) according to NFPA 13 Maximum Slope Ceiling 2 inch rise for 12 inch run (16.7%) Maximum Spacing 10 feet (3,1 m) In some cases, the installation stan- dards permit a greater spacing. Minimum Spacing 8 feet (2,4 m) Temperature Rating 165°F (74°C) and 212°F (100°C) Deflector Distance from Walls Minimum of 4 inches (102 mm) from walls but no more than 1/2 the allow- able distance permitted between sprinklers Deflector to Top of Storage Minimum of 36 inches (914 mm) Deflector-to-Ceiling Distance 6 to 14 inches (152 to 356 mm) Maximum Ceiling Height 48 feet (14,6 m) Maximum Storage Height 43 feet (13,1 m) Storage Arrangement Palletized, solid piled, open frame, single row, or double row Commodity Class l-IV; Cartoned, unexpanded plastic Sprinkler System Design NFPA 13 for ESFR Sprinklers based upon 45 psi (3,1 bar) design pressure, 169 gpm (640 1pm) with 12 sprinkler remote area Minimum Aisle Width 5 feet (1,5 m) TFP3I2 Page 4 of 4 FITTING SIDE TOWARDS SPRINKLER FITTING I WRI RE( FIGURE 2 W-TYPE I SPRINKLER WRENCH Installation TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Damage to the fusible Link Assem- bly during installation can be avoided by handling the sprinkler by the frame arms only (i.e., do not apply pressure to the fusible Link Assembly), and by using the appropriate sprinkler wrench. Failure to do so can lead to an unstable link assembly and premature activation of the sprinkler. Damaged sprinklers must be replaced. A leak-tight 1 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 20 to 30 lbs.-ft. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Note: Install the Model ESFR-25 Pendent Sprinkler in the pendent posi- tion (Ref. Figure 2). Step A. With pipe thread sealant applied, hand-tighten the -sprinkler into the sprinkler fitting. Do not apply pres- sure to the Link Assembly, and handle the Model ESFR-25 Pendent Sprinkler only by the Frame arms. Step 2. Wrench-tighten the Model ESFR-25 Pendent Sprinkler using only the W-Type 1 Sprinkler Wrench (Ref. Figure 2) and by fully engaging (seating) the wrench on the sprinkler wrench flats (Ref. Figure 1). Step 4. After installation, inspect the Link Assembly of each Model ESFR-25 Pendent Sprinkler for damage. In par- ticular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assem- bly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. Care and Maintenance TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Model ESFR-25 Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226), (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) ..................58-441-1-165 212°F (100°C) .................58-441-1-214 Special Order Sprinkler Assemblies with ISO 7-1 Thread Connection Specify: Model ESFR-25, Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226) with ISO 7-1 thread connection, (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) .................. 58-442-1 -165 212°F (100°C) .................58-442-1-214 Sprinkler Wrench Specify: W-Type 1 Sprinkler Wrench, P/N 56-872-1-025 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. tqco MONEL and INCONEL are trademark of Special Metals Corporation. Fire Protection Products TEFLON is trademark of DuPont Corporation. // I Limited Warranty SprinkFLEXa warrants that its products will be free from defects in materials and workmanship under normal conditions of use and service for a period of one year from date of sale. Our obligation under this warranty is limited to repairing or replacing any product that is returned to us with transportation charges prepaid within one year after the date of original sale and that our examination shows to our satisfaction to have been defective in materials or workmanship under normal conditions of use and service. The decision as to whether to repair or to replace any product shall be made by us, and any repair shall be made at our facility, Notwithstanding the foregoing, the following are specifically excluded from the coverage of this warranty: (a) the sprinkler head of any SprinkFLEX® product, but SprinkFLEX® hereby assigns to the original purchaser of any such product the right to enforce the warranty, if any, issued by the manufacturer of such sprinkler head; (b) defects resulting from ordinary wear and tear, of any SprinkFLEX® Product; products that have been altered in any manner by the buyer or by anyone other than SprinkFLEXC; products that have been subjected to misuse, abusive use, or damage by accident or casualty; products that have been installed or used in a manner contrary to our specifications, instructions or recommendation; products that have been installed or used in a manner that is not in compliance with all applicable requirements of any code law, regulation or rule of any federal, state or local governmental or industry authority; and products that have not been inspected and maintained in accordance with our specifications, instructions or recommendations, including, without limitation, our recommendations as to following the inspection and maintenance standards published by the National Fire Protection Association (NFPA); and products that have been affected by Microbiologically Influenced Corrosion (MIC). This warranty is not assignable and shall benefit only the original purchaser of a SprinkFLEX® product. If any provision hereof or any portion of any provision shall he held invalid, the remainder of this Limited Warranty shall not be affected thereby, and all provisions of this Limited Warranty shall remain Valid and in full force and effect to the fullest extent permitted by law. THIS WARRANTY IS IN LIEU OF ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY AND WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. NOTWITHSTANDING ANY PROVISION TO THE CONTRARY HEREIN OR ANY APPLICABLE LAW TO THE CONTRARY, IN NO EVENT SHALL - SFRlNKFLEX BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES UNDER ANY CIRCUMSTANCES WHATSOEVER, WHETHER ARISING FROM ANY BREACH OF THIS LIMITED WARRANTY OR OTHERWISE ARISING I FROM OR IN CONNECTION.WITH THE USE OR OPERATION OF, OR ANY DEFECT IN, ANY SPRINKFLEXa PRODUCT, OR OTHERWISE, The risk of damages from any breach of warranty with respect to injury to any person will be born by the purchaser of SprinkFLEX. - - •'-•-r Series SFN Unbraided Flexible Hose Assemblies CUS usno Series SFB Braided Flexible Hose Assemblies Z° c®us APPRUVHJ USTED SprinkFLEX® Stainless Steel Sprinkler 'ittings connect the branch line to the sprinkler using a flexible s:ainles.s steel hose and reducer. The flexible stainless steel hose and fittings are intended for direct connecticn to the sprinkler and are particularly suited for use in suspended and hard ceiling applications. Each drop assembly comes wiih one stainless steel flexible hose, one branch line connection nipple, one sprinkler reducing nipple and bracket system. SYSTEM OPTIONS Fre-assembled, ready to install, unbraided and braided flexible stainless steel hose lengths: 28" (700mm), 40" (1 000mm), 48" (1200mm), 59' (1500mm), 71" (1800mm) ½" and 1/4"outlet fittings for connecting sprinkler ?re-assembled, ready to install mounting bracket available in 24" and 48" long Mounting bracket allows the sprinkler to be located anywhere within the ceiling with reference mark-s in the center for ease of nstallation without the need for measuring. Optional factory installed sprinkler heat. - TECHNICAL DATA Maximum Working Pressure: 200 psi (i 375 kPa) Maximum Ambient Temperature: 300° F (149°C) Connection to Branch Line: 1-inch NPT Minimum Bend Radius of Flexible Sta nless. Steel Hose: :3 inches (76.2 mm) per UL Listing 3 inches (203.2 mm) per FM Approval The flexible stainless steel hose should not be bent within 21/2 irches (64 mm) of the connection nut at both ends. Equivalent lengths are shown with maximum number of 90 degree bends at the minimum bend radius. 2-45 degree or 3-30 degree bends equal 1-90 degree bend FM equivalent length calculation include spinkIer head Friction Loss, UL equivalent length calculalior iiclude the hose only. UL Maximum K-Factor of Sprinkler to be ccnnected to Sp-inkler Reducing Nipple: /2 inch outlets: 8.0 3/ inch outlets: 11.2 FM Maximum K-Factor of Sprinkler to 1e connected to Sprinkler Reducing Nipple: inch outlets: 5.6 3/ inch outlets: 8.0 Listings and Approvals: Unbraided models are UL Listed Braided models are FM Approved and JL Listed FLEXIBLE HOSE - NON BRAIDED c®us I USTED NO. DESCRIPTION NO. DESCRIPTION 1 Flexible Hose /8" Nominal Diameter 5 Nipple 2 Ring 6 Reducer /z"or%" 3 Washer 7 Plastic Cap Slip Nut 0 FLEXIBLE HOSE - BRAIDED \ \ CO APPROVED c®us USTED NO DESCRIPTION NO.,DESCRIPTION 1 Flexible Hose /" Nominal Diameter 5 Nipple 2 Ring 6 Reducer A" or %" 3 Washer 7 Braid 4 Slip Nut 8 Plastic Cap BRACKET ASSEMBLY r - \ NO. DESCRIPTION NO. DESCRIPTION 1 24" or 48" Support Bar 4 Hex Screw I 2 Center Bracket Assembly 5 Wing Bolt If 3 Clamp MATERIAL SPECIFICATIONS Corrugated Flexible Hose: SS304 Support Bar: G90 Galvanized Steel SEAL: EPDM Clamp and Center Bracket Assembly: G90 Galvanized Steel SLIP NUT AND NIPPLE: Zinc-Plated Carbon Steel Hex Screw and Wing Bolts: Zinc-Plated Carbon Steel Slip Nut and Nipple: Zinc-Plated Carbon Steel Optional Tamper-Resistant Screw: Zinc-Plated Carbon Steel BRAID AND BRAID RING: SS304 FRICTION Loss DATA UNBRAIOEO HOSE UL LISTED MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH (mm) Iii 3" BEND RADIUS MAXIMUM NUMBER OF 9O DEGREE BENDS UL LISTED — UNBRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 401" DIAMETER PIPE (C=120), FT 1 x 1/2 28" (700mm) 2 22 SFN28T 28 (700mm) 2 SFN40H 1 x 40(1000mm) 3 39 SFN40T 1 x 3A 1000mm) 54 SFN48H 1 x½ 1200m 56 ____________ SFN48T 1 x3A 48 ____________ <:2Z 63 SFN59H 1 x1/2 -do ___________________ (1500mm) 3 59 SFN59T 59" (1500mm) 3 74 71" (1800mnn) 3 1 3A 71(1800mm) 3 74 Series SFN models are unbraided/Series SF8 models are braided Unbraided hoses are UL Listed Braided hoses are FM Approved and UL Listed BRAIDED HOSE FM APPROVED AND UL LISTED MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH (mm) UI 3" BEND RADIUS MAXIMUM NUMBER OF 90 DEGREE BENDS UL—BRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 401 DIAMETER PIPE (C=120), FT FM 8" BEND RADIUS MAXIMUM NUMBER OF 90 DEGREE BENDS FM—BRA!DED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 401 INCH DIAMETER PIPE (C=120), FT SFB28H 1 x 1/2 28" (700mm) 2 24 1 46.4 SFB28T 1 x% 28" (700mm) 2 29 1 39.1 SFB40H 1 x1,4 - 40 (1000mm) 3 44 - 1 53.9 SFB40T 1 x3A 40" (1000mm) 3 54 1 45.3 SFB48H 1 x 1/2 48(1200mm) 3 63 2 73.4 SFB48T 1 x% 48(1200mm) 3 . 55 2 64.3 SFB59H 1 xVz - 59(1500mm) 3 76 - 3 89.9 SF8591 1 x% 59"(1500mm) 3 - 70 3 86.5 SFB71H 1 x½ 71(1800mm) 3 78 4 112.8 SFB71T 1 1 x% 71(1800mm) 3 92 4 1104.9 BRAIDED HOSE WITH ELBOW - FM APPROVED MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH (mm) FM 8" BEND RADIUS MAXIMUM NUMBER OF 90 DEGREE BENDS FM—BRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 401" DIAMETER PIPE (C=120), FT 1 x 1/2 28" (700mm) 1 48.4 SFB28T-E 28" (700mm) 1 SFB40H—E 40(1000mm) 55.9 SFB40T-E 1x 3/4 1000mm) 47.3 SFB48H—E 1 X 1/2 1 4 75.4 SFB48T—E 1xY4 66.3 SFB59H-E —ft (1500mm) 91.9 _________________________ _______________________ SFB59T—E 59" (1500mm) 71(1800mm) 4 j H_E 2 1 x% 71(1800mm) 4 106.9 I T I t2 ;T •'-" 5\ - Jiim = ç 47, fLL L J FPPI ULIULC Listed 300 psi Description FPPI® TrimFit® Bronze* Globe Valves are precision cast then machined using state of the art facilities Each valve features a full floating seat holder for reduced seat wear when closing the valve. Seat is made of pure virgin PTFE for longer seat life and reduced maintenance as compared to rubber seat valves. TrimFit trim valves are suitable for use in regular (1 75psi) and high pressure (300psi) sprinkler systems. Standard configuration is FNPT x FNPT and is available in ¼" IPS through 2" IPS sizes. Each valve carries the UL Listing UL/ ULC Listed 2R97 Installation Specifications Install in accordance with usual and customary installation techniques for fire sprinkler systems. Use a suitable thread sealant on the male threads of the pipe Material: Brass* or Bronze* being threaded into the valve body. We recommend either FPPI PTFE Thread Seat-PTFE Sealing Tape or PipeFit® Thread Sealing Paste with PTFE. NEVER USE BOTH. Hand wheel-JIS FC 20 DO NOT OVERTIGHTEN, OVERTIGHTENING MAY CAUSE CRACKS OR painted red. LEAKS. Sizes 06-798-00 1/4" IPS FNPT 06-800-00 1/2" 06-802-00 3/4" 06-804-00 1" 06-806-00 11/4" 06-808-00 11/2" 06-810-002" *Contains lead. Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 _......- TEL + 1760 599-1168 D +1800344-1822 FAX® 1 800 344-3775 © 2015 Fire Protection Products, Inc. PipeFif, TrimFit, and FPP18 are registered trademarks of Fire Protection @ c Products Inc. LISTED LISTED V4XZMYS1 APPROVED 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST 20 X 2.1/2 850 1.5 X 4 1475 1.5 8068925 GST 20 SS X 2-1/2 850 1.5 8010957 GST 30 X 4 1500 : 1.5 X 4 1475 1.5 8009925 GST 25-380 X 4 1500 1.5 8022925 SWG 25-380 X 3-1/2 - 4* 1500 1.5 8021957 SWG 20 X 2-1/2 3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SH GST 2O X 3 1050 1.5 X 4 1475 1.5 8141957 SH GST 3O X 4 1500 1.5 X 4 1475 1.5 Minimum Minimum ULMax Pipe ULTest FM Max FM Test BX P/N STEEL UL Steel FM Steel Size, in. Load i Thickness, n. Pipe Size Load Thickness, in. 8038957 DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 FBX P/N CONCRETE FM FM Max FM Test Material Pipe Size Load 8059957 CST 20 X 4 1475 3000 PSI 8061957 SWC20 X 4 1475 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3' / UL and FM tests were performed in compliance with NFPA-13 Standards. r ,... Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. V UI ex www.itwbuildex.com 800-284-5339 SSS26 0506 Fig. 65 Patent #4,570,885 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1/,6 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1 /16 1 /4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 1hI4' Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4 (Fig. 66). Features - All steel construction eliminates structural deficien- cies associated with casting type beam clamps. May be used On top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification VVVV-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Finish - Plain Note - Available in Electro-Ga Ivan ized and HDG finish. Order By - Figure number, rod size and finish. Scs OFFICE/MANUFACTURING FACILITY • 1315 SAMPSON AVE. • CORONA, CA 92819 • PH: 951.731.5599 • FAX: 951.137.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number .' Fig. 99 - All Thread Rod Cut to Length Fig. 100 .- All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Ga Ivan ized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1114 8000 7140 360 11/2 11630 10370 510 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping ' purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - o (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily A installed around pipe. (21/2 thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel .. V? THRU 2 N( and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-17 1 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200 WON. Order By - Figure number and pipe size 4 I 1 A 2 112ThRU 8 INCH PIPE Dimensions 'Weights Pipe Rod Size. Max. Rec. Approx. Size Inch Metric --_ A B . Load Lbs. Length 1/2 3/8 8mm or 10mm 31/8 26/a 400 11 3/4 3/8 8mm or 10mm 31I 21/2 400 11 1 3/8 8mm or 10mm 31/8 2°/s 400. 12 11/4 3/8 8mm or 10mm 33/4 2/ 400 13 11/2 3/8 8mm or 10mm 37/s 2/ 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 . 10mm 55/s 41/ 600 27 3 3/8 10mm 51/s 4 600 29 31/ . 3/8 10mm 7/e 51/ 600 34 4 3/8. 10mm 73/s 5 1000 35 5 1/2 12mm 91/6 6V4 1250 66 6 1/2 12mm 101/8 6/4 1250 73 8 1/2 12mm 131/8 8/4 1250 136 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 9 Customer Service • 800.786.5266 www.tolco.com Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range - 3/8" and 1/2' rod; 4" thru 16" length.** Material - Pre-Galvanized Steel Function -To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1. Features - Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mecha- nism of some kind, such as the beveled locking slot of the Fig. 69R or a hex nut tightened against other types of retaining straps will provide a more secure and reliable installation. Approvals Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By Figure number, rod or set screw size and length Note - Minimum return on Strap: 1". * Patent #5,94 7,424 Dimensions • Weights Rod Size A Length 3/8" Specify 1/2' Specify Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 wwwlolco.com Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe.. Material - Steel Function - Designed to be used in conjunction with TOLCOTM Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed pnly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2'. Patent #5,344,108 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona. CA 92879 • Ph: 951737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com Aluminum & Stainless Steel Aluminum Aluminum channels, fittings and accessories offer excellent corrosion resistance and are suitable for many indoor and outdoor applications. AJumnum's high strength to weight ratio helps greatly reduce overall cost of installation through ease of handling and cut:ing. Channels are extruded from aluminum alloy 6063-T6. Closure strips are extruded from eluminum ahoy 6063-T5. Fittings and accessories are made from aluminum alloy 5052-H32, Stainless Steel Where corrosion problems persist and other material and fittings are ineffective, we recommend use of corrosion resistant stainless steel channels and accessories. Channels and fittings are available in two types ol stainless steel SS4-AISI Type 304 :SS6-AlSl Type 316 Fittings Most fittings, as shown in this catalog, can be supplied in aluminum or stairless steel. Consult factory or possible minimum production quantities and set-up charges. Load Data Aluminum Channel's approximate load data an be determined by multiplying load data Vi the steel channel section of this caalog by a factor of 0.38. Stainless Steel Channel loac data is the same as :be data in the steel channel section of this catalog. Metric Metric dimensiois are shown ir parentheses. Unless noted, all metric dimensions are in millimeters. BLine by Tfl 177 Strut Systems Aluminum Channel & Closure Strips B11AL Thickness: .105 (2.6 mm) Standard Length: 10' (3.05 ml and 20' (6.09 ml Material: Aluminum Weight: 1.06 Lbs./Ft. (1,58 kg/m) 31/4 15/8' I,_...1 (41.3) BI2AL Thickness: .105 (2.6 mm) Standard Length: 10' (3.05 ml and 20' (6.09 ml Material: Aluminum Weight: .86 Lbs./Ft. (1.28 kg/m) V/16" (61.9) 1/8" (41.3) B22AL Thickness: .105 (2.6 mm) Standard Length: 10' (3.05 ml and 20' (6.09 ml Material: Aluminum Weight: .66 Lbs./Ft. 10.98 kg/m) 1/8" j (41.3) SL (41.3) B22AAL Thickness: .105 (2.6 mm) Standard Length: 10' (3.05 ml and 20' 16.09 ml Material: Aluminum Weight: 1.18 Lbs./Ft. (1.75 kg/m) \ 31/4" (82.5) 1 /8" (41.3) B54AL Thickness: .080 (2.0 mm) Standard Length: 10' (3.05 ml and 20' (6.09 ml Material: Aluminum Weight: .37 Lbs./Ft. (0.55 kg/m) B24AL Thickness: .080 (2.0 mm) Standard Length: 10' (3.05 ml and 20' (6.09 ml Material: Aluminum Weight: .52 Lbs./Ft. 10.77 kg/m) B54AAL Thickness: .080 (2.0 mm) Standard Length: 10' (3.05 ml and 20' (6.09 ml Material: Aluminum Weight: .57 Lbs./Ft. (0.84 kg/m) 11/8'. (41.3) B217AL Closure Strip Standard Length: 10' (304.8 cm) Material: Aluminum Weight: .15 Lbs./Ft. (0.23 kg/m) B217P Plastic Closure Strip Standard Length: 10' 1304.8 cm) Material: PVC Weight: .09 Lbs./Ft. (0.14 kg/m) B217FFAL Closure Strip Standard Length: 10' (304.8 cm) Material: Aluminum a Weight: .16 Lbs./Ft. (0.24 kg/m) (36.5) Reference page 177 for general fitting specifications. Other channel combinations available-see steel section for styles. B-Line Strut Systems 178 by 't4J SH Type Channel Material: Aluminum 2' TYP. // / Slots (14) (28.6) Aluminum K06 Type Knockout Channel Material: Aluminum 6" (152.4) 3"/// (22.2) Dia. KO H Part No. Thickness in. mm H in. mm Wt./C Lbs./Ft. kg/rn B12SH AL .105 (2.6) 27/1611(61.9) .83 (1.23) B22SH AL .105 (2.6) 1I8" (41.3) .63 (.93) B24SH AL 080 (2.0) 1 5/8" (41.3) 49 (73) B54SH AL .080 (2.0) 13/16" (20.6) .34 (.50) H-17/8 Type Channel Material: Aluminum Thickness H Wt./C Part No. in. mm in. mm Lbs./Ft. kg/rn B12K06 AL .105 (2.6) 2/16" (61.9) .86 (1.28) B22K06 AL .105 (2.6) 1/8" (41.3) .66 (.98) B24K06 AL 080 (2.0) 15/8" (41.3) 52 (77) B54K06 AL .080 (2.0) 13/16 (20.6) .37 (.56) B2000 Series Rigid Conduit Clamps Safety Factor of 5 Machine Screw and Square Nut included Pipe clamp material 5052-H32 Design Load 17; . . / 9/16,, (14.2) Dia. Holes Thickness H Wt./C Part No. in. mm in. mm Lbs./Ft. kg/rn B12H17/8 AL .105 (2.6) 2/16" (61.9) .86 (1.28) E12211-111W8 AL .105 (2.6) 1/8" 141.3) .66 (.98) 624H17/8 ALI 080 (2.0) 15/8,, (41.3) 52 (77) B54H17/8 AL .080 (2.0) 13/16" (20.6) .37 (.55) Conduit or Material Design Part No. Pipe Size Thickness Load Wt./C in. mm in. mm Lbs. kN Lbs. kg 1132001 AL /8" (10) .063 (1.6) 180 (.80) 4 (1.8) B2008 AL 1 /2" (15) .063 (1.6) 180 (.80) 4 (1.8) B2009 AL 3/4 (20) 080 (2.0) 270 (1.20) 6 (2.7) B2010 AL 1" (25) .080 (2.0) 270 (1.20) 7 (3.2) B2011 AL 11/4 (32) 080 (20) 270 (120) 8 1361 B2012 AL 11/2 (40) .100 (2.5) 360 (1.60) 11 (5.0) B2013 AL 2 (50) 100 (25) 360 (1.60) 12 (54) B2014 AL 21/2 (65) .100 (2.5) 360 (1.60) 13 (5.9) B2015 AL (80) .100 (2.5) 360 (1.60) 16 17.21 B2016 AL 31/2" (90) .125 (3.2) 450 (2.00) 22 (10.0) B2017 AL (100) .125 (3.2) 450 (2.00) 24 (10.9) B2018 AL 41/2" (115) (3.2) 450 (2.00) 26 (11.8) B2019 AL 5 (125) 1 ,121 125 (32) 450 (200) 27 (122) B2020 AL 6" (150) .125 (3.2) 450 (2.00) 33 (14.9) Reference page 177 for general fitting specifications. Other channel combinations available-see steel section for styles. B-Line by ET*N 179 Strut Systems Aluminum Aluminum Fittings Most fittings, as shown in this catalog, can be supplied in aluminum. See "Fittings" section (page 73) of this catalog. Consult factory for possible minimum production quantities and set-up charges. Channel Nuts We recommend the use of Stainless Steel channel nuts with Aluminum channel. For channel nut pull-out strength and slip resistance, use the channel nut information provided on pg. 51 & 52. A (.70) multiplier is to be applied to obtain the appropriate derated values for aluminum channel. Spring Nut Nut Without Spring Nuts for B12 Channel Part Number With Without Thread Thickness Wt./C Spring Spring Size in. mm Lbs. kg N724556 N224W05S6 1/4".20 1/4" (6.3) 6.6 (3.0 N728556 j N228W0SS6 3/8"-16 /8" (9.5) 106 (4.8) N725SS6 N225W0556 1/2"13 3/8" (9.5) 9.7 (4.4) Nuts for B22, B24 Channels Part Number With Without Thread Thickness Wt./C Spring Spring Size in. mm Lbs. kg N224556 N224W0SS6 1/4".20 1/4" (6.3) 6.6 (3.0) N2285S6 N228W0SS6 3/811-16 /8 (9.5) 10.6 (4.8) N225SS6 N225W0SS6 1/2".13 /8" (9.5) 97 (44) Nuts for B54 Channel With Spring Part Number Without Spring Thread Size Thickness in. mm Wt./C Lbs. kg N524S56 N224W0SS6 1/4"..20 1/4" (6.3) 6.6 (3.0) N528556 N228W0SS6 /8"-16 /8" (9.5) 10.6 (4.8) N525S56 N525W0556 1/2".13 /8" (9.5) 9.7 (4.4) Reference page 177 for general fitting specifications. Other channel combinations available-see steel section for styles. B-Line Strut Systems 180 by fT*1 B22SS* *Substitute 4 for Stainless Steel Type 304 or 6 for Stainless Steel Type 316 Thickness: 12 Ga. (2.6 mm) Standard Length: 10' (3.05 m) and 20' (6.09 rn) Material: SS4, SS6 Weight: 1.90 Lbs./Ft. (2.83 kg/m) B32SS4 Thickness: 12 Ga. (2.6 mm) Standard Length: 10' 13.05 ml and 20' (6.09 rn) Material: SS4 Weight: 1.70 Lbs./Ft. (2.53 kg/m) 15/8 " (41.3) (25.4) Reference page 177 for genera) fitting specifications. Other channel combinations available-see steel section for styles. 181 Strut Systems B-Line by EFN Stainless Steel B24SS* *Substitute 4 for Stainless Steel Type 304 or 6 for Stainless Steel Type 316 'Thickness: 14 Ga. (1.9 mm) Standard Length: 10' (3.05 ml and 20' (6.09 ml Material: SS4, SS6 Weight: 1.40 Lbs./Ft. (2.08 kg/m) 1(41.3) B42SS4 Thickness: 12 Ga. (2.6 mm) Standard Length: 10' (3.05 m) and 20' (6.09 ml Material: SS4 'Weight: 1.44 Lbs./Ft. (2.14 kg/m) 15/8" (41.3) 11352SS* B54SS* *Substitute 4 for Stainless Steel • *Substitute 4 for Stainless Steel Type 304 or 6 for Stainless Steel 13/16" Type 304 or 6 for Stainless Steel 13/16" Type 316 r'.. (20.6) Type 316 (20.6) Thickness: 12 Ga. (2.6 mm) \ • Thickness: 14 Ga. (1.9 mm) \ \ 'Standard Length: 10 (3.05m) \ i 'Standard Length: 10' (3.05m) o Material: SS4, SS6 • Material: S54, SS6 Weight: 1.27 Lbs./Ft. 11.89 kg/m) • Weight: .97 Lbs./Ft. (1.44 kg/m) 15/8 1/8" (41.3) r j (41.3) SH Type Channel 2" Typ. / Slots (14.2) Thickness H Wt./C Part No. in. mm 1 in. mm I Lbs./Ft. kg/rn B22SH SS4 12 Ga. (2.6) 5 1/8" (41.3) 1.82 (2.70) B22SH SS6 12 Ga. (2.6) 1/8" (41.3) 1.82 (2.70) B24SH SS4 14 Ga. (1.9) 1/8" (41.3) 1.34 11.991 B24SH SS6 14 Ga. (1.9) 1/8" (41.3) 1.34 (1.99) B32SH SS4 12 Ga. (2.6) 1/8" (34.9) 1.62 (2.41) B42SH SS4 12 Ga. (2.6) 1" (25.4) 1.36 (2.02) B52SH SS4 12 Ga. (2.6) 13/16 (20.6) 1.23 (1.83) B52SH SS6 12 Ga. (2.6) 13/16" (20.6) 1.23 (1.83) B54SH SS4 14 Ga. (1.9) 13/16" (20.6) .91 (1.35) B54SH SS6 14 Ga. (1.9) 1 13/16" (20.6) .91 (1.35) H-17/8 Type Channel , 1 'I 1/8" Typ. / / / /16" (14.2) Dia. Holes HI / Part No. Thickness in. mm H in. mm Wt./C Lbs./Ft. kg/rn B22H17/8 SS4 12 Ga. (2.6) 1/8" 141.31 1.85 (2.75) B22H17/8 SS6 12 Ga. (2.6) 15/8 (41.3) 1.85 (2.75) B24H17/8 SS4 14 Ga (1.9) 1/8 (41.3) 1.36 (202) B24H17/8SS6 14 Ga. (1.9) 1/e" (41.3) 1.36 (2.02) B32H17/8 SS4 12 Ga (26) 1/8 (349) 1.65 (245) B42H17/8 SS4 12 Ga. (2.6) 1" (25.4) 1.39 (2.07) B54H17/8 SS4 14 Ga. (1.9) 13/16" (20.6) .93 (1.38) B54H17/8SS6 1 14 Ga. (1.9) 1 13/16" (20.6) .93 (1.38) Stainless Steel Stainless Steel Fittings Most fittings, as shown in this catalog, can be supplied in Type 304 or Type 316 stainless steel. See Fittings' section (page 73) of this catalog. QQ Consult factory for possible minimum production quantities and set-up charges. B2000 Series Pipe & Tubing Clamps Safety Factor of 5 Combination Recess Hex Head Machine Screw and Square Nut included Material: Stainless Steel Type 304 & 316 Design Load Part No. Conduit or Pipe Size in. mm Material Design Thickness Load in. mm Lbs. kN Wt./C Lbs. kg B2001 SS4 /8" (10) 16 Ga. (1.5) 400 (1.78) 10 14.5) B2008 SS4 1/2" (15) 16 Ga. (1.5) 400 (1.78) 11 (5.0) B2009 SS4 3/4" (20) 14 Ga. (1.9) 600 (2.67) 15 (6.8) B2010 SS4 1" (25) 14 Ga. (1.9) 600 (2.67) 16 (7.2) B2011 SS4) 11/4 (32) 14 Ga Ii 9) 600 (267) 20 (91) B2012 SS41 11/2" (40) 12 Ga. (2.6) 800 (3.56) 30 (13.6) B2013 SS4 2' (50) 12 Ga. (2.6) 800 (3.56) 34 (15.4) B2014 SS4 21/2' (65) 12 Ga. (2.6) 800 (3.56) 38 (17.2) B2015 SS4 (80) 12 Ga. (2.6) 800 (3.56) 44 (19.9) B2016 SS4 31/2' (90) 12 Ga. 12.61 1000 (4.45) 51 (23.1) B2017 SS4 (100) 12 Ga. (2.6) 1000 (4.45) 55 (24.9) B2018 SS4 41/2" (115) 12 Ga. (2.6) 1000 (4.45) 59 (26.7) B2019 SS4 5 (125) 12 Ga (2.6) 1000 (4.45) 64 (290) B2020 SS4 l 6" (150) 12 Ga. (2.6) 1000 (4.45) 1 80 (36.3) -- Channel Nuts For Channel Nuts pull-out strength and slip resistance, use the data shown on pages 50 & 51. Note: Reduce slip load by 50% due to hardness of material. Spring Nut Nut Without Spring Nuts for B22, B24, 832 Channels Part Number With Without Thread Thickness Wt./C Spring Spring Size in. mm Lbs. kg N2245S6 N224W0S56 1 /4"..23 1/4" (6.3) 6.6 (3.0) N228SS6 N228W0SS6 3/8"-16 3/81,(9.5) 10.6 (4.8) N2255S6 N225W0556 1/2"..13 /8" (9.5) 9.7 (4.4) Nuts for B42, B52, B54 Channels Part Number With Without Thread Thickness Wt./C Spring Spring Size in. mm Lbs. kg N524SS6 N224W0556 1/4"20 1/4" (6.3) 6.6 (3.0) N528SS6 N228W05S6 /"-16 3/8" (9.5) 10.6 (4.8) N525556 N225W0SS6 1/2"..13 3/s" (9.5) 9.7 (4.4) Reference page 177 for general fitting specifications. Other channel combinations available-see steel section for styles. B-Line Strut Systems 182 by Threaded Accessories HN - Standard Hex Nut (TOLCO Fig. 113) Size Range: 1/4"20 thru I8°-9 Material: Steel Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number size and finish Part For Width Across Width Across Approx. Number Rod Size Flats Points Thickness W000 in. (mm) in. (mm) in. (mm) lbs. (kg) HN-1/4 1/4°..20 7A6° (11.1) ½ (12.7) /32° (5.7) 0.7 (0.3) HN-3/e 3A'- 16 /i ° (14.3) 21/32° (16.6) 21/6° (8.3) 1.6 (0.7) HN 'k ½ 13 3/4 (190) 55/64 (218) /16 (111) 37 (17) HN 5/8 5A'- 11 15A6° (23.8) 1/32 (27.8) 35/64° (13.9) 7.3 (3.3) HN 3/4 j/4-10 1½ (286) 1/1 (3 3.3) 41/64 (163) 120 (54) IlN-7/8 iB°-9 15A6° (33.3) 1 /64° (38.5) 3/4° (19.0) 19.0 (8.6) HHN - Heavy Hex Nut (TOLCO Fig. 114) Size Range: 1/4°20 thru /8°-9 Material: Steel Finish Plain or Flectro Ga(vanized Contact B-Line for alternative finishes and materials. Order By: Figure number size and finish -. Part For Width Across fl Width Across Approx. Number Rod Size Flats Points Thickness W000 in. (mm) in. (mm) in. (mm) lbs. (kg) HHN 1/4 1/4 20 ½ (127) 37/54 (147) /64 (59) 12 (05) HHN-318 3/B°-16 11A6 (17.5) 51/64° (20.2) : 23/64° (9.1) 3.1 (1.4) HHN-1/2 14°-13 7A" (22.2) 1½ (28.6) 31/64° (12.3) 6.5 (2.9) HHN-5/8 ½-li 11A6 (27.0( 1½4 (31.3) /64" (15.5) 12.0 (5.4) HHN 3/4 3/4 10 11/4 (317) 129A4 (369) /64 (186) 190 (86) HHN-1/8 (36.5) 12142 (42.6) /64° (21.8) 30.0 (13.6) B-Li Nne All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. by LT*N 102 Fire Protection Solutions p Threaded Accessories FW - Flat Washer (TOLCO Fig. 115) ØTLCO Size Range: 1/420 thru V-8 rods Material: Steel ( ( Finish Plain or Electro Galvanized '•. Contact B Line for alternative finishes and materials - " Order By: Figure number size and finish Part For Outside Approx. Number Rod Size Diameter Wt./100 in. (mm) lbs. (kg) FW 1/4 1/4'-20 3/4 (190) 07 (03) FW-3/8 3N-16 1 (25.4) 3.9 (1.7) FW-1/2 ½-13 13W (34.9) 6.7 (3.0) FW-5/8 ,-ii 13/4 (44.4) 7.3 (3.3) 3/4 -1O 2 (50.8) 11.0 (5.0) FW-7/8 7A -9 21/4 (57.1) 19.0 (8.6) FW1 V-8 214 (698) 220 (100) LW - Lock Washer (TOLCO Fig. 117) Size Range: 1/420 thru V-8 rods Material: Steel Finish: Plain or Electro-Galvanized. Note: Available in Hot Dip Galvanized finish or Stainless Steel materials. Order By: Figure number size and finish Part For Outside Approx. Number Rod Size Diameter Wt./100 in. (mm) lbs. (kg) LW-1/4 '/4-20 .49 (12.4) 0.3 (0.13) LW-3/8 3A'- 16 .68 (17.3) 0.6 (0.27) LW-'k ½'-13 .88 (22.3) 1.3 (0.59) LW-5/8 5A% 1i 1.08 (27.4) 2.4 (1.09) LW-3/4 3/4'- 10 1.27 (32.2) 3.8 (1.72) LW-1/e 1"_9 1.46' (37.1) 5.9 (2.67) LW-1 1 -8 1.66 (42.1) 8.8 (3.99) FFW - Flat Fender Washer (TOLCO Fig. 119) Size Range: /8-16 and 1/213 rods Material: Steel Function: To provide a greater bearing surface than standard washer. Finish Plain or Electro Galvanized Contact B-Line for alternative finishes and materials. .-. Order By: Figure number and size Part For Inside Outside Approx. Number Rod Size Diameter Diameter wt./100 in. (mm) in. (mm) lbs. (kg) FFW-3/a 3W-16 ½ (12.7) 1½ (28.6) 3.0 (1.3) FAN-1/2 ½-13 9M (14.3) 2 (50.8) 2.8 (1.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-line Fire Protection Solutions 103