Loading...
HomeMy WebLinkAbout3337 TYLER ST; ; FPR2020-0011; PermitPERMIT REPORT (ity of Carlsbad Print Date: 01/05/2021 Job Address: 3339-3355 TYLER ST, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: TYLER ST RESIDENCES -SPRINKLER MONITORING (ADDRESSABLE, 5 DEVICES) Permit No: FPR2020-0011 Status: Closed - Finaled Applied: 02/21/2020 Issued: 03/05/2020 Finaled Close Out: 08/17/2020 Inspector: Final Inspection: Applicant: FPContractor: HCI SYSTEMS INC HCI SYSTEMS INC VAN ESSA MONTOYA 4585 MURPHY CANYON RD 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 SAN DIEGO, CA 92123-4318 (909) 628-7773 (858) 560-7000 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov PP&2_010 - Do I HCI Systems Inc. FIRE I LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Fire Alarm System Complete Material Submittal Prepared for: [1 TYLER STREET RESIDENCES BUNGALOW 3337 TYLER STREET, CARLSBAD, CA 92008 Ontario • San Diego • Irvine • Hayward • Burbank • Fresno • Sacramento Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (909) 628-7773 FAX: (909) 628-7774 24-Hour Service: (877) 331-2084 Website: www.hcisystems.net 0 TYLER STREET RESIDENCES BUNGALOW 3337 TYLER STREET, CARLSBAD, CA 92008 Manufacturer Device Model # C.S.F.M. # Description EDWARDS FX-lORD Fire Alarm Control Panel 7165-1657:0102 EDWARDS 521 B Conventional Photoelectric Smoke Detector 7272-1657:0277 EDWARDS SIGA-270 Manual PullStation 7150-1657:0111 SPACE AGE ACE-11 Fire Alarm Document Cabinet 7300-0553:0110 TELGUARD TG-7FS Fire Alarm Cellular Alarm Communicator 7300-1402:0109 S fl qt,~UniledTechnologiies ll Small Building Fire Alarm Solutions Technology that saves lives Conventional Fire Alarm Systems ((X-1 oRb') FX-1OR, FX-5RD, FX-5R Ck * FDNY COA 6230 Overview Kidde brand conventional fire alarm systems consist of 5 and 10 zone fire alarm control panels (FACP), an optional integrated upload/download DACT (dialer), intelligent/analog type detector features, serial annunciator modules, and serial remote relay mod- ules. All FACPs and components are Listed to the 10th edition of the ANSI/UL 864 standard and CSFM/FDNY approved. Standard Features Available in 5 and 10 zone (IDC) models CleanMe® feature provides remote annunciation of a dirty detector Automatic drift compensation with select detectors reduces false alarms and extends dust life Listed to ANSI/UL 864 10th Edition These systems incorporate features designed to simplify installation, operation and maintenance, including front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with CleanMe® -compatible smoke detectors, these con- trol panels provide intelligent type features such as remote mainte- nance alert and automatic drift compensation that significantly reduce the chance of a false alarm and simplify maintenance calls. Kidde systems are powerful enough to meet the demands of today's life safety installations while leaving plenty of room to grow in the future. They support Class A operation by combining pairs of on-board lDCs or NACs to provide the necessary Class A circuits. For example, the FX-10RD comes factory set to support 10 Class B lDCs and 4 NACs. But it can be field-configured to provide 5 Class A lDCs (no Class B IDC's), and 2 Class A NACs - or any other com- bination of circuits that fall within the circuit-pairing parameters. FX-1OR(D) FX-5R(D) Class BlDCs UptolO Upto5 Class AIDCs Upto5 Upto2 Class B NACs Up to 4 Up to 2 Class A NACs Up to 2 1 NAC Power 7.0 amps 3.5 amps Auxiliary power 0.5 amps 0.5 amps Notes: Class A operation will reduce the number of available Class B IDCs and/or NACs, depending on the panel configuration. See Specifications for details. Models with fully integrated upload/download DACT enables PC programming Zone or NAC pairs convertible to single Class A circuits Combination Waterflow and Supervisory lDCs NACs programmable by zone and individually selectable for notification appliances, continuous, temporal outputs, or coded Front panel programmable simplifies installation and servicing Precision synchronization with compatible notification appli- ances and optional audible silence over two wires On-board relays for Alarm, Supervisory and Trouble Optional serial bus relay modules are programmable for Com- mon, Zone, or Matrix activation Optional serial bus remote annunciator family One person walk-test (audible or silent) Optional City Tie and Reverse Polarity Modules Trim ring available for semi-flush mounting Page lof8 OAT\ SkErT K850050126 Nf t . 0 r •:..i 0 11 Issue 2.2 S Application Kidde conventional fire alarm systems provide smoke and fire de- tection, occupant notification and off-premises signaling for small- to medium-sized buildings. Each IDC can be configured for either Class B or Class A opera- tion and one of eight operating modes: Alarm —with or without smoke detector verification including discrimination of contact devices Waterfiow Alarm; Waterflow Alarm/Supervisory (Combination IDC); Supervisory (Latching/non-latching); Monitor (non alarm or supervisory) Signal Silence Drill Cross zoning NACs may also be configured for either Class B or Class A operation, Additionally, NACs can be individually configured for one of six outputs. These are Genesis, Genesis (1AN silenceable), Continuous, Temporal, Coded, and City Tie. The Genesis selec- tion allows independent horn control over two wires and provides precision synchronization of notification appliances, all without the need for a signal master accessory. When configured for compatible notification appliances, the Alarm Silence function will silence connected audible appliances but strobes will remain active until the panel is reset. When Genesis Mode is selected, both the horns and strobes on compatible notifi- cation appliances will be synchronized across all NACs. Note: Zones may be selected for either latching or non-latching operation. Always check with your AHJ regarding approval of silencing audible while leaving strobes flashing. Detectors with intelligent features at a conventional price When combined CleanMe -compatible smoke detectors, Kidde systems provide intel- ligent features at a conventional price. If a CleanMe® detector drifts out of the UL sensitivity range, Kidde's patented remote maintenance reporting sends an alert to the control panel. This feature reduces the chance of a false alarm and simplifies service calls. In addition, CleanMe® -compatible smoke detectors have built-in drift compensation that extends the time between cleanings. If cleaning is ever necessary, it is literally a snap with the Kidde exclusive replaceable optical chamber. For a complete list of CleanMe® compatible smoke detectors, visit http.-IlKidde-fire.com. Panel LED Display The following system LEDs display the panel's status: Alarm - panel is in the alarm state; Trouble - panel is in the trouble state; Supervisory - panel is in the supervisory state; Power - indicates the status of the AC power source; Disable - indicates when any IDC, NAC, relay or the DACT is disabled; Annunciator Trouble - indicates trouble on the remote an- nunciator bus; Battery Trouble - indicates battery or charging problems; Ground Fault - indicates a short between any panel circuit and ground; Walk Test - indicates that one or more IDCs are in the walk test mode; Alarms Silenced - indicates that the panel is in the alarm state with one or more NACs silenced. Waterfiow - indicates that one or more circuits have detected an active waterfiow switch. Service Detector - indicates the presence of a dirty detector with CleanMe® compatible ESL smoke detectors. Remote Disconnect - indicates off site communication has been disabled. Each IDC has a disable switch and three LEDs: Alarm - red - indicates that the IDC is in the alarm state; Trouble - yellow - indicates that the IDC is in the trouble state or is disabled (when flashing); Supervisory/Monitor - yellow - indicates that the IDC is in the supervisory state or the monitor state (when flashing). Each NAC also has a disable switch and a trouble/disable LED Status indication with the DACT/Dialer installed The optional upload/download dialer's LCD display provides two lines x 16 characters of text. For programming, the top line displays the programming step and the lower line displays the selected option. All system events are displayed on the LCD with custom zone messages. During normal operation, the LCD will display any off-normal condition present in the panel. IP and Cellular Communications Several popular third-party IP/Cellular communicators have been tested with the FX conventional control panels and are compatibil- ity listed to UL864. The IP/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the FX con- ventional control panel compatibility documentation part number 3101019-EN for a full list of compatible communicators. S S Page 2 of 8 DATA $HU1 K85005-0126 Not to L d for - Issue 2.2 The Remote Relay Module (FSRRM24) is one feature of the system that sets these systems apart from other panels in their class. This module has five Form C relays rated at 1 amp each. It can be configured to function in either a zone relay mode or a common system mode. When configured in the zone relay mode, relays energize when the as- sociated IDC is active. The module can be configured for activation by lDCs 1 through 5 or lDCs 6 through 10. One relay is automatically associated with each IDC. When configured in the common system mode, relays energize or de-energize when the panel changes c1itgc (rcc rli Ic nvnilnhhn 0 p,evlous device Frc,cccc,frclpeflei To nwd device for each of the following Co,n,rnrnloeioniec)-1 —.—.com,nvnhoeionoo- oc COncrnciceionh->--] E+Communication ovi° functions: Alarm, Supervi- sory, Trouble, Power Loss, Monitor. The FSRRM24 mounts on a plastic snap track and can be installed in an MFC-A enclosure. The panel will support two RAMs of each configuration for a total of six on the 10-zone panel. 1.4V IN C IN C OLfr OUT' JJL J 0 Frifi 0 h4fi UT NC II ji : The Remote Relay Module mounts on a plastic track inside an MFC-A cabinet. ;el-1I Uptotwo RRM24s can be [—_--J mounted in an 1J r•] FSRRM-SI I snap ( track. Up to two V ll FSRRM-SIIs can be mounted in an RRM MFC-A. Power Connections Main AC wiring bloc kdl and fuse holder Dual transformer AC wiring block\ Tie wra mounts N -1-L F_1~ net From 120 Vac, 15A, 60 Hz Dedicated branch circuit A fully integrated upload/download dialer is available for reporting Options Off-premise communication events to a monitoring facility. The DACT also supports uploading or downloading of system configuration, status and event history. The DACT is programmable for either single or dual line opera- tion. It also supports split and dual reporting for two digital alarm receivers. I The DACT brings additional features to the panel including a 32-character alphanumeric LCD display, local or remote PC pro- gramming and an event history log. Remote Annunciators and Relays The seal bus standard on Kidde conventional control panels is o another installation time-saver. This circuit allows the connection of Main Remote System Indicators (FSRSI), Remote Zone Indicators (FSRZI- Main ler9 controller board A, FSRZI-SA) and Remote Relay Modules (FSRRM24) over a four- isforner wire (data and power) circuit. Annunciator and relay modules can be installed up to 1,000 feet from the panel on 18-gauge wire. o Modules are also available for City Tie (CTM) and Reverse Polarity (RPM) connections. Mounting studs connector Upload/Download DACT/Dialer Remote Relay Module C The DACT/Dialer installs be- hind the front panel display. Note: All panel versions are available with factory installed DACT See order table for ordering informa- tion. The built-in DACT/Dialer is a muitifunc- tion module that provides communi- cations, modem capability, and LCD display functions. Its primary function is as a Digital Alarm Communica- tor Transmitter (DACT). As a DACT, it transmits event messages to a Digital Alarm Communicator Receiver (DACR) at a monitoring facility. The monitoring facility then notifies the fire department and other responsible parties of the event. Programmable options include split or dual reporting to two DACRs. The DACT module can also be used as a modem to connect the panel to both local and remote computers for uploading and downloading of con- figuration data (programming), panel status and event history. For security, the modem can be configured to ac- cept programming on incoming calls or it can be required to call a prepro- grammed number before accepting downloads and sending uploads. The DACT module can be configured to work as all of the above, or as only an LCD display or LCD display and modem. Page 3 of 8 flA1 A SHEET K85005-0126 I Issue 2.2 ira ur III UIlI LuIIuI IIll lii uIl ira U.lI liii. —Luu FAR IFil Z.1.1 24V 24V To next remote module C Fran, C control panel or 24V5C power oupply Fro control panel ON: Group 1 OFF: Group 2 Remote Annunciators This family of systems has several remote annunciation options. The serial remote annunciator bus can be run up to 1000 feet (305 m) on untwisted r: non-shielded 18-gauge cable. Several annunciator models round out the family to provide a range of features and functions. As many as three an- - nunciator modules may be mounted in a standard electrical box, sharing F an attractive trim plate that blends with any decor. The FSRSI can be installed alone or with one or more FSRZI-As. The FSRSI and FSRZI-A require film plates (ordered separately). These are available in one, two or three gang models. Each panel will support two FSRSIs. Compatible electrical box Remote System Indicator - Remote Zone Indicator (FSRSI) (FSRZI-A) The FSRSI is ideal for The FSRZI-A is used to common system annuncia- indicate zones in the alarm tiori. It includes five LEDs state. It contains five red and a local silence/lamp - LEDs. Depending on the — test switch. The LEDs mdi- jumper setting selected, cate power status, alarm, -- the LEDs will indicate either supervisory, trouble and lDCs 1 through 5 or lDCs 6 ground fault. The silence through 10. The panel can Coxnewxt.xonxt >— switch will silence the °°"" >— I support two modules pro- onboard trouble sounder FOfl4POT1 I I I grammed for each selection peo,rin. if active. The switch can '°°''°' also be used to initiate a JLJL 24V IN C IN lamp test of the LEDs on all connected FSRSls and Ll FSRZI-As. P000 Out d Teex4exc, - Remote Zone Indicator (FSRZI-SA) The FSRZI-SA indicates zones in the Alarm or Su- pervisory state. It contains five red and yellow LEDs for — Common, Zone, or Matrix activation. Depending on the jumper setting, the LEDs will Cn,eex4e,tOUnCO >—i indicate either lDCs 1- 5 or 6 I -10. The panel supports two 0m+o00000flIfl modules for each selection, 2. IN j and can be jumper selected to C IN provide Alarm or Supervi- V OLJT sory indications. Peel, xxxi. power ox, V Ceeounoolxtn .. Co,nnrxrd0000eouo+ TO root doxixe TLU To next dIxie, FSRA10, FSRA10C Remote LED annunciators The FSRA10 is a remote annunciator with capacity for up to ten zones. It includes ten bi-color LEDs (red/yellow) for indicat- ing active zones, and ten yellow LEDs for indicating zone troubles. The (C) option adds common control switches. Both ver- sions mount to standard North American 4-inch square electrical boxes. A surface box is also available. Works only with 10 zone panel. FSRA10, FSRA10C Wiring V - FSUIM Graphic Driver/Interface The FSUIM is a universal interface module that can be used by to I drive graphic annunciators. It also allows control panels to control, LS or be controlled by, other control panels. The FSUIM provides five supervised switch inputs and nine dry contact relay outputs. Nine LEDs provide visual confirmation when each relay is energized. The FSUIM is shipped with a plastic snap track for mounting in an - MFC-A enclosure. From control panel or 24VDC supply From control panel From content pond or ZCVDC power Supply * tone4 remote module cc C Page 4 of 8 r. A S H El I K85005-01 26 F1tt to b for lo x? ..ix . 'P - Issue 2.2 Remote Annunciator Specifications General Agency Listings I UL864 (S3000), ULC, CSFM, FDNY Remote Annunciators FSRSI Remote System Indicator FSRZI-A/FSRZI-SA Remote Zone Indicator Maximum per System All panels: 2 10 zone panel: 4 5 zone panel: 2 Current Requirements Standby: 17 mA Alarm: 56 mA Standby: 8 mA Alarm 76 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Maximum Circuit Capacitance 0.03 i.iF Maximum Circuit Resistance 13 Ohms Wire Size 18- 12 AWG (0.75 mm2 -2.5 mm2) Mounting ANSI/N EMA OS 1-1996 1-3 gang electrical box Operating Environment Temperature: 32 - 120° F (0- 49° C); Humidity: 93% RH, non-condensing Remote Relay Module - FSRRM24 Configured for Zone Mode Configured for Common Mode Maximum per system 10 zone panel: 4; 5 zone panel: 2 All panels: 2 Current Requirements Standby: 10 mA; Alarm: 70 mA Standby: 26 mA; Alarm: 70 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Contact Rating 1 A@ 30 Vdc Maximum Circuit Capacitance 0.03 i.iF Maximum Circuit Resistance 13 Ohms Wire Size 18 - 12 AWG (0.75 mm2 - 2.5 mm2) Mounting Single FSRRM24 mounts in plastic track (included) or up to two FSRRM24s in an FSRRM-S1 111" track ordered separately. FSRRM24s should be installed in an MFC-A enclosure. Operating Environment Temperature: 32 - 120° F (0- 49° C); Humidity: 93% RH, non-condensing Dimensions 2-3/4" W x 3-3/8" H x 1-1/2" D (65.9 mm W x 85.7 mm H x 38.1 mm D) F-Series Remote Annunciators FSRAIO FSRA10C Common Controls No I Yes Compatibility 10-Zone Panels Only. Dimensions 5-5/8" x 81/2" x 1 1/2" in (14.3 cm x 21.4 cm x 3.8 cm) Mounting North American 4-inch square electrical box Power Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) Data Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) twisted pair (6 twists per foot minimum) Operating voltage 18.8 to 27.3 Vdc Supply must be UL/ULC listed for fire protective signaling systems. Do not use FACP accessory power outputs that are interrupted when the panel is reset. Standby current 17 mA Alarm current 98 mA Operating environment Temperature: 32 to 120 °F (0 to 49 °C); Humidity: 0 to 93% RH, noncondensing at 90 OF (32 °C) FSUIM Universal Input Module Mounting MFC-A enclosure Wire size 12 to 18 AWG (0.75 to 2.5 sq mm) Operating voltage 21.2 to 27.3 Vdc Circuit capacitance 0.03 pF, max. Circuit resistance 13 ohms, max. Switch inputs Quantity: 5 End-of-line resistor: 4.7 k ohms ½ W Relay outputs Quantity: 9 Type: Common Style: Form C Contact rating 30 Vdc at 1 A (resistive load) Standby Current 53 mA Alarm Current 114 mA Operating environment Temperature: 0 to 49 °C (32 to 120 °F); Humidity: 0 to 93% RH, noncondensing at 32 °C (90 °F Page 5 of 8 OATA sHEEr K85005-0126 ' ttob ,.,1tor i? , Issue 2.2 01 Surface mounting holes Dl o E (I) E a) 'CO 0 0 0 D4 Control Panel Specifications Control Panels 1OR(D) FX-5R(D) Initiating Device Circuits - lDCs (Available combinations shown at right) Class B 10 8 6 4 2 0 5 3 1 Class A 0 1 2 3 4 5 0 1 2 Notification Appliance Circuits - NACs (Available combinations shown a: right) Class B 4 2 2 0 2 0 Class A 0 1 1 2 0 1 Power Supply 7.5 amps total 4.25 amps total NAC Voltage Rating 24 Vfwr Maximum NAC current 2.0 amps each, 7.0 amps total 2.0 amps each 3.5 amps total AC Input 120 Vac 60 Hz... 230 Vac 50/60Hz... 2.2 amps 1.1 amps 1.25 amps 0.6 amps Base Panel Current Draw Standby... Alarm... 128 mA 242 mA 104 mA 224 mA Panel Battery Charge Capacity (sealed lead acid only) Up to two 24 ,Ah batteries, 18 Ah in cabinet Up to 24 Ah, 10 Ah max in cabinet * Auxiliary Current 0.5 amps max. May be programmed as resettable. Auxiliary Output 24 Vdc regulated DC Alarm Current 3.0 mA (Consult detector compatibility list p/ri 3101019-EN for maximum detectors per circuit) IDC Circuit Maximum loop resistance: 26 Ohms; Maximum loop capacitance: 0.03 hF IDC Operating Voltage 16.9 to 29 Vdc UL Detector ID 100 Alarm Contact (normally open Form C) 30 Vdc @ 1 A (resistive load) Trouble Contact (Form ) 30 Vdc @ 1 A (resistive load) Supervisory Contact (normally open Form C) 30 Vdc © 1 A (resistive load) Operating Environment Temperature: 32 - 120° F (0 - 49° C); Humidity: 5 - 93% RH, non-condensing Terminals (wire gauge) 18 - 12 AWG (0.75 mm2 - 2.5 mm2) Asynchronous Serial Communications Maximum resistance: 13 Ohms; Maximum capacitance: 0.03 i.iF Agency Listings UL864 (S3000), ULC-S527, CSFM, FDNY If larger batteries are required, use an external battery cabinet. DACT - F-DACT (mounts _in_panel) Receivers Supports two receivers with two phone numbers each Communications Protocol Contact ID (SIA DC-05), 4/2 (SIA DC-02 P3) Programming Front panel controls or PC with appropriate software Telephone line connection Two RJ31X (plug-to-plug) cords supplied with DACT Telephone lines Two or one loop start lines on the public switched telephone network. Pulse or DTMF. Telephone wall connector RJ31X/CA31X equiv. or RJ38X/CA38X equiv. Communications Compliance Industry Canada CS-03; FCC/CFR 47 Parts 15 & 68; NFPA 72; UL 864; ULC S527 Operating Environment Temperature: 32-120° F (0-49° C); Humidity: 93% RH, non-condensing Current requirements Standby: 65 mA; Alarm: 107 mA Agency Listings UL864 (S3000), CSFM,FDNY Dimensions Model DI* D2 D3 D4 D5* Five- 19.5 in 3.75 in 9.13 in 10.5 in 14.23 in zone (49.5 cm) (9.5 cm) (23.2 cm) (26.67 cm) (36.14 cm) Ten- 30 in 3.75 in 7.75 in 21.27 in 15.0 in zone (76.2 cm) (9.5 cm) (19.7 cm) (54.0 cm) 1138.1 cm) *Add 11/2 inches (3.81 cm) 'o Dl and D5 dimensions for trim kit Page 6of8 041A SHFF t K85005-0126 Not to bv u d fr ',•tdL1t1cl, . i. Issue 2.2 Ordering Information Part Number Description Ship Wt. lb. (kg.) Control Panels Conventional Fire Alarm Control Panel, Red - 10 Class B lDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of FX-1OR lDCs and NACs convertible to single Class A circuits), 120VAC power source, 24VDC output • Conventional Fire Alarm Control Panel, Red - 10 Class B lDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of - - - FX-10RD lDCs and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 30.5 (13.8) 24VDC output Conventional Fire Alarm Control Panel, Red - 10 Class B lDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of Fx-10RF lDCs and NACs convertible to single Class A circuits), 120VAC power source, 24VDC output, French Canada Conventional Fire ,Jarm Control Panel, Red -5 Class B lDCs and 2 Class B NACs, 3.5A NAC power, (Pairs of lDCs FX-5R and NACs convertible to single Class A circuits), 120VAC power source, 24VDC output Conventional Fire Alarm Control Panel, Red - 5 Class B lDCs and 2 Class B NACs, 3.5A NAC power, (Pairs of lDCs FX-5RD and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 24VDC 24.4 (11.1) output Conventional Fire Alarm Control Panel, Red, 5 Class B lDCs and 2 Class B NACs, 3.5A NAC Power, 120V, 24Vdc FX-5RF Output, French Canada F-1R1M35R Semi-flush trim ring for FX-5R(D) 1.7 (0.8) F-TRIM1OR Semi-flush trim ring for FX-10R(D) 2.2(l.0) Related Items F-XTR120 Expander Transformer, 120 Vac - For FX-10 only - 4.0 (1.8) E01-3.6-1.1 Required UL listed End of Line Resistors - One 3.6K Ohm and one 1.1K Ohm. 0.1(0.6) One required for each IDC configured as combination waterfiow and supervisory. EOL-P1 Required ULC listed End of Line Resistor Plate - includes one 1.1K, 3.6K and 4.7K Ohm resistor 1.0 (0.5) Off Premises Communications F-DACT Upload/dowload digital Communicator/modem/LCD module (Mounts in control panel) 1.0 (0.5) F-DACT1 Digital Communicator/Modem/LCD module (Compatible with new v4.0 control panels) F-DACT1 F Digital Communicator/Modem/LCD module (Compatible with new v4.0 control panels), French CTM City Tie Module (Requires 4" square or 2-gang North American electrical box) 1.0 (0.5) RPM Reverse Polarity Module (Requires MFC-A or other listed fire alarm enclosure) 3.0 (1.4) Remote Annunciation FSRSI Remote System Indicator - Includes LEDs for display of Power, Alarm, Supervisory, Trouble and Ground Fault, trouble sounder and silence/lamp test switch. Single gang trim plate included, multi-gang plates ordered separately. Mounts in a single or multi-gang North American electrical box. 0.3 (0.1) FSRZI-A Remote Zone Indicator - Includes red LEDs for five lDCs. Single gang trim plate included, multi-gang plates ordered separately. Mounts in single or multi-gang North American electrical box. 0.3(0.1) FSRZI-SA Remote Zone Indicator - Includes LEDs for five IDCs. Single gang trim plate included, multi-gang plates ordered separately. Mounts in single or multi-gang North American electrical box. Jumper selected Alarm (red) or Supervisory (amber) indications. 0.3 (0.1) FSAT1 Annunciator Trim Plate, 1 gang 0.1 (0.05) FSAT2 Annunciator Trim Plate, 2 gang 0.1 (0.05) FSAT3 Annunciator Trim Plate, 3 gang 0.1 (0.05) FSAT4 Annunciator Trim Plate, 4 gang 0.1 (0.05) K-FSRA10 Single Unit 10 zone remote annunciator for FX-10 K-FSRA1 OF Single Unit 10 zone remote annunciator for FX-10, French K-FSRA10C Single Unit 10 zone remote annunciator for FX-10 (with common controls) K-FSRA10CF Single Unit 10 zone remote annunciator for FX-10 (with common controls), French FSUIM Common Function Graphic Driver/Interface - 9 relays and 5 switch inputs for common system indicators & controls Remote Relay Module FSRRM24 Remote Relay Module - Five Form C relays. Configurable for lDCs 1-5, or 6-10, or common system indications or 0.4(0.2) matrix mode. Requires MFC-A or other listed fire alarm enclosure. FSRRM-S1 1 11" Mounting track. Holds up to two FSRRM24s. 0.4 (0.2) Accessories MFC-A Multi-function Cabinet (fire alarm accessory enclosure) 7.0 (3.2) - Programming Tools FA-CU Fire alarm configuration utility. This CU is available for download only. Visit www.kiddefx.kidde.com. Page 7 018 DATA SHEET K850050126 to, ., r Issue 2.2 Q Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: kidde. corn/en gineeredsystems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment. All rights reserved. S Page 8of8 AT' ;HEr K85005-0126 N. 1 10 .. . . Issue 2.2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No (7165 T57 O1ö2' Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models FireShield series FS302x, FS502x, FS1004x, *Models FireShield Plus FSP302x, FSP502x, FSPI004x, *Models FireworX series FX-3x, FX-5x,X-10'and *Models FSC- series E-FSC302x, E-FSC502x, E-FSC1004x fire alarm control units. The suffix x' may include any of the following alpha and/or numbers: G, R, G-2, GF, GD!D') GC or *F. Models FSDACT and *F..DACT digital alarm communicator transmitter. Local, auxiliary, central station, remote station, automatic, manual, waterfiow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. . This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. *This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-1591:102, 7165-1501:129 7-29-10 ma , . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other ON Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EDWARDS Catalog ' Conventional Initiating ithies lF-E SAFElY INCIDENT MANAGEMENT Conventional Multi-Purpos'e Smoke Detectors with Auxiliary Functions 500 Series I S1125 A 7272-1657: 0277 Overview 500 Series two-wire conventional photoelectric smoke detectors bring together trusted technology and a full line of features that meet the demands of every type of application. The 500 offers sounders in two-wire applications, specifically to meet residential code requirements. EDWARDS is also proud to offer proven technology like CleanMe®, dust compensation, field replaceable optical chambers, and self-diag nostics. CleanMe® is only available on the 500 2-wire models and will communicate with compatible FACPs when servicing is required. 500 Series detectors work on a light-scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high- speed photo diode as the sensing element. This design has supe- rior protection against nuisance alarms caused by dust, insects, RF interference, and ambient light. The proprietary optical chamber is field replaceable. In the event of a confirmed alarm the LED will light continuously. The unit indi- cates trouble by flashing the LED every second. This meets the NFPA 72 field sensitivity testing requirements. Additional diagnostic information is activated by applying a magnet near the detector integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. The magnet test causes the LED to blink. The number of blink counts corresponds to a smoke detector sensitivity range. Models with a built-in 85dB sounders emit the temporal 3 pat- tern and can be easily tandemly interconnected using the 405-05 polarity reversal relay. This enables all detectors to sound when the initiating detector sounds and meets the requirement of the International Residential Building Code (IRC). Standard Features Remote maintenance (CleanMe®) reporting and built- in drift compensation reduces false alarms Self-diagnostics meets NFPA 72 sensitivity testing re- quirements without the need for external meters Field-replaceable optical chamber makes service fast and simple Large SEMS screw terminals accept 12-18 AWG wire Small, low profile design blends with any environment Optional auxiliary functions include: Integral sounder with optional tandem interconnection Auxiliary relay Listed for applications such as elevator recall Fire system isolated heat integrated with non- latching single station smoke alarm Integral fixed/ROR heat detectors Page 1 of 4 DATA SHEET E85001-0606 Not to be used for installation purposes Issue 1 Application 500 Series detectors are ideal for both retrofit applications and new installations alike. They are particularly well-suited for installa- tions where detector reliability is essential, but where typical ana- log/addressable devices may not be appropriate or feasible. With their replaceable optical chambers, these detectors are equally ell-suited to dusty environments where detectors require frequent cleaning. Assembly Optional fixed temperature sensor Diagnostic LED Optional rate-of-rise sensor Photoelectric sensor __ Replaceable optical chamber and bug screen Detector cap Mounting and Installation Dimensions 500 Series detector bases mount directly to standard single-gang electrical boxes, three-inch round, or four-inch octagonal boxes. Detector heads simply twist onto the base. Heads are equipped with a break-away locking tab, which prevents unauthorized re- moval. SEMS terminals accept 24 to 12 AWG field wiring. 512cm (0) Typical Wiring 2-wire Initiating + Circuit Listed Alarm Control - EOL Device - - Last First Detector Detector (\\\ Specifications Electrical Power Supply 8.5-33VDC (12/24 V operation) polarity sensitive Maximum ripple pk-pk (6/12/24\i) 10% (Vpk-pk) Typical average standby current 70 i.IA Typical alarm current (6/12/24V up to 60 mA max if not limited by control panel Auxiliary relay contacts 1.0 A © 30 VDC; Form C (521 NCRXT only) Photoelectric sensitivity 3.1% + 0.5 - 1.0% Environment Operating temperature 320 to 1000 F (00 to 370 C) Operating humidity range 0 to 95% non-condensing - RA immunity 20 V/rn mm; 0- 1000 MHz Physical Color White Field wiring size 12-18 AWG (16-22 recommended) Heat detector specifications Rate-of-Rise: 15° F/min and >105° F (8.3° C/min and >40.6° C) Fixed Threshold: 135° F (57.2° C) UL 2-wire compatibility identifiers S09A, S1 OA, S11A Sounder output (521 NCSXT only) 85dB © 10 feet Drift compensation adjustment 1.0% ft. max Detector head dimensions 5.5 D x 2' H (14.0 x 5 cm) Mounting dimensions 5.25' (13.3 cm) diameter; 0.3" (0.8 cm) height Regulations Reset time 1 second mm 500N Series: UL 268 cUL, CSFM (21B 521 B)C1 UL 268, CSFM 528B, 528BX1 ULC Page 2 of 4 DATA SHEET E85001-0606 Not to be used for installation purposes. Issue 1 Ordering Information Model Description Compatibility Alarm Current Reverse (mA) polarity (mA) 521 B 2-wire, photoelectric, 8.5-33VDC; UL 268, CSFM Listed S09A'S10A 5 mm. - 60 max. 521BX1 2-wire, photoelectric, 8.5-33VDC, fixed temp and rate-of-rise heat; S09NS10A 5mm. -60 max. UL 268, CSFM Listed 521 NCRXT 2-wire, photoelectric, 8.5-33VDC, fixed temp and Si 1A 15 min. - 60 max; rate-of-rise heat, aux. relay; UL 268, cUL, CSFM Listed 521NCSXT 2-wire, photoelectric, 8.5-33VDC, fixed temp and rate-of-rise heat, S1 OA 10 mm. -60 max 10 temporal 3 sounder; UL 268, cUL, CSFM Listed Note: Only 500 Series 2-wire smoke detectors are CleanMe compatible. Accessories 405-05 Polarity reversal module enables sounder interconnection of all 4-wire smoke detectors, when initiating detector sounds all smokes sound. SM200-1 2PKG Smoke! in a Can® canned smoke for functional testing SM-EXT1 Smoke! in a Can® extension tube 211-10PKG Replacement optical chambers (set of 10) S S Page 3014 DATA SHEET E85001-0606 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0606 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7272-1657:0283) Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models '521NB 541 NB, '521 NC, 52INBXT, *521NcxT 52INCRXT, 52INCSXT, 52INCSRXT, 54INBXT, 541 NCSRXT, 541 NCSXTE, 54INCSRH, 541NCRXT, 541NCXTE, 541 NCSXT, and FX5-2S1 photoelectric type, conventional smoke detectors. . All models except 521 NB, *521 NC and 541 NB employ a supplemental heat sensor. Models with NCS suffix also employ an integral supplemental three pulse temporal sounders. The Model FX5-2ST is provided with a CleanMe feature. The integral heat sensor and sounder are intended for use only as a supplemental to the smoke detector. They are NOT approval for use as a required initiating or indicating devices. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 6.5-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. Formerly: 7300-0447:110 *Rev 12-18-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification cf any claims. This listing is not an erdorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division cLD 7z L [EJ LIFE SAFETY INCIDENT MANAGEMENT Fire Alarm Stations 270 Series EDWARDS Catalog t Conventional Initiating S2318 * 7150-1657: 0111 MEA Overview (EDWARDS 270 Series Non-Coded Fire Alarm Stations are sturdy, attractive, and designed for economical installation. • The station is available in the following operational and functional designs: - The 270 Serie.provides a single action, break glass initiat- ing station. It is available with normally open (NO.), normally closed (N.C.) or combination N.O./N.C. contacts. The basic 270 Series have screw terminals for field connection. The 270A Series Manual Stations have 6 inch (150mm) wire leads. - The 270P Series is a break glass, normally open pre-signal station. The pull of the lever sounds an alarm on all pre-signal indicating devices. Inserting a key and turning it will initiate a general evacuation alarm. Screw terminals are provided for field connection. All non-coded statins are designed for either flush or surface mounting. For flush mounting a 4 inch standard North American square box with single gang plaster cover should be used. For surface mounting the 270 Series or 270P Series, use P-027193 Cast Box, P-039250 Steel Box Housing for weatherproof enclo- sure. Standard Features Pull lever Simple positive operation Break glass Attractive, streamline design Less than 5 lb pull force complies with ADA Solid, die-cast metal construction E Page lof2 DATA SHEET E850010303 Not to be used for installation purposes. Issue I (FE SAFETY & INCIDFNT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Mounting (2m)36mmI 1-II2' i 3-lW r- (82mm) ooc RELEASE WAIL SURFACE FOR TEST & RESET AND LASS REPLACEMENT IN LUDEDWffH STATIONS) ONLY I s-P.S-I. GEN ALARM KEY SWITCH INCLUDED WITH (I 14MM)ONLY PR -SIGNAL STATIONS) DETAILS FLUSH MTG. UNIT FITS 450 BOX & PLASTER COVER WITH P27165 GLASS ROOJ SINGLE GANG OPENING HAVING OVERALL MW. DEPTHOF2II4 FLUSH INSTALALTION USING P.024900 STEEL BOX 3-1W ' V 3-Wl (80mm) 3l/2 3-5/32 180mm) -1 )25mm)r (90mm) (26mm) o 1f (118mm) _ _ I7-1r11 0 L bfl (114mm) FRONT SIDE 1 ° STEEl. SURFACE BOX FRONT CAST SURFACE BOX SIDE P.0390 P.027193 Ordering Information All models are fire alarm red with Aluminum Strips. WARNING: These devices will not They are marked 'Pull in Case of Fire" on the pull handle. operate without electrical power. Cat. No. Marking Switch Contacts Field Connections Pre- As fires frequently cause pow- (top of Signal er interruptions, we suggest you device) Single Double Open Screw Wire Pre- discuss further safeguards with your Pole Pole Circuit Terminals Leads Signal local fire protection specialist. 270-DPO Fire Alarm - 270-DPO- Local / L Alarm 270-SPO Fire Alarm / 270A-DPO Fire Alarm 270A-SPO Fire Alarm 270P-DPO Fire Alarm V V .1 1 270P-SPO Fire Alarm V / / V Page 2 of 2 DATA SHEET E85001-0303 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL l - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No 'i'150-1657:0111" Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models C270) 270P, 270-SPO, 270A-SPO, 270-DPO, 270A-DPO, 270-DOC, 276B, 277B, 278B, 279B, 279TC, 279P, 279T, 279L, 276A-REL, 278A-REL, 5966B, 5966BR, 5966BV, 5966BRV, 629613-270, 6296B-K279, 6296B-T279, 8557-13301, 8557-13311, 8558-13301, 8558-13311 and 8558-13312 manual pull stations*. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as non-coded fire alarm pull stations for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. NOTE: 1. Models provided with two-wire lead and normally closed switch contacts are not approved for fire alarm signaling use. 2. Formerly 7150-1591:111, 7150-1388:121 and 7150-0073:117 7-29-10 ma J zjj This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SIGNALING LISTED Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1/4 deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Ll, FAD ACE-1 1/ FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords Solid stainless steel piano hinge and other critical system information. Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information Space Age Electronics, Inc. Made IS.A. REGftRED/'www.lsa 800.486.1723 Toll Free e!om MEMBER 508.485.0966 Local 508.485.4 Space Age Electronics, Inc. 2009 No Excuses, Just Solutions! ED0549 LT1 0559 Rev.D 1/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (73O0-O553:011 o) Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TCI-18, TCXJA 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFX/A and IFX/D enclosures. Models 'ACE-11) ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc ø' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ?SPACE AGE JELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-1 Connector property Information Ca,tlficatlonn and Approval. 16.1 System installation Contractor floonvatodhmc.,oSonoI.dod tOdndW.OSNFPAOa,dotth,dflS,, no- 16.5 Authority Having Jurisdiction: ho. thoOd ochoon, .nnann n.h a .yc.n.cdf.,dh.hb.blSd.}dO.,.th,gpO,.dy riO hr .,ncOd 00. &0 ancah000. St oncod 0 0,90.0. tO S 1*00____________ Equipment Infonnatlon Mlnlmhm. Required Documentation (SIG-FUN) an-- 3fl,n0.'0v,OflnM,otOtO,fSdot.Mo.00.600m 4S.o].o.0,no.do 0.0.. 1,9*0 9,00 000*0,0.0. .h,1, IB.ons 'at(Mr n.r.c. 90.h1 •1• .0*0.0) $V*rdvpsvto.(n,rdflcaw.pplov.&c.t Or C00*Sd000cl.h9,0100d0009l*.o.000.otl,8600702 100,900*0 9, d,6o.nk*a 0.0.0. *00 736001.02 66 C,9y0.0..onov,*0o..pp*c.o, *29,0* *00*00*000 1.7 1000i00I,.p.ctI0, IuI*o,dn0*Ir.rc.d,o,O.lih,.c0d.,.0th0*0jc.7.6 60*00: 002: _L_ — 6,ac.090000vnlwffl,. 52 fl0*c Road 000,9.0001604 000.404-1*02 mn.1....arn LT10644 Re, 1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description ssu00685 Fire Alarm Storage Cabinet RED Space Age Electronics, Inc SSU00686 Custom screening with your Log www.lsae.com 800.486.1723 Toll Free Check out our Infinity line eFAD single gang 2 Gig digital storage 508.485.0966 Local solutions (IAMEFAD) 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0549 LTI 0559 Rev.D 2/2 AA TELGUARD I Power Transmit power: 1.0W-2.0W (maximum allowable). Power Consumption: 60mA (Standby) 250mA (Transmission). Transformer: 12VAC, 800 mA UL listed plug-in. Radio Transceiver 3G cellular radio. GSM 850MHz: Class 4 (2 watts). GSM 1900MHz: Class 1(1 watt). UMTS WCDMA FDD 850/1900MHz. Antenna: 9" dipole with 2dBi gain. 12 ft of cable and universal mounting bracket. I • FCC part 15, 22, 24 and 68 compliant. 5• - •5 Physical Details TG-7FS: 7.5" H x 11.5" W x 3.5" D. Shipping Weight: 81bs. Operating Environment: 0°C to +50°C; up to 95% humidity (non-con den sing). I Standard Features Full data reporting. Automatic self-test (5 mm. & daily). Power supply with battery harness. Locking, red metal enclosure. Two programmable supervisory trip outputs. Alarm format support for SIA2 Contact ID pulse (3x1 4x2) modem lie & lila2 DMP Telephone line monitor built-in, -', with Standard Line Security. CELLULAR ALARM TG=7FS COMMUNICATOR FOR 3G/4G NETWORKS Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical. and UL Listed. Accessories ACID 12, ACID 35, ACID 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-O: External antenna. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and systems 1610 Central station burglar alarm units: Line security servcies Residential 985 Household fire warning systems For the most cutest oroduct speciiicvtior" sod J1 L5tinnjs visit wvrns'Tiguvrd.corc. cl%t LJ \l[ A"PIA NFPA LISTED INTERNATIONAL Telguard, a Division of Telular Corporation 2727 Paces Ferry Road SE Suite 1-800 Atlanta. GA 30339 us 800-229-2326. Option 5 • www.lelguard.com • Copyright c 2012 Telular Corporation • All Rights Reserved TE LG UAR D CELLULAR ALARM TG=7FS COMMUNICATOR FOR 3G/4G NETWORKS ô COMMERCIAL FIRE PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. Provides RMR protection by leveraging technology that operates on 3G/4G networks. Supports listen-in, two-way voice verification over cellular. - Minimizes false alarms by providing dual paths for self-tests. :- Falls back to 2G (GSM) if a 3G/4G network isn't available. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than ( a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can he installed as the sole path for commercial fire installations. For existing installations, all landlines can he swapped for a single TG-7FS because of the new five minute supervision mode. The TG-7FS can also he installed as a backup path and upgraded to sole path at a later date. r Telguard Online Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface TeIguardCeIIuIar Service Telguard Cellular Service provides i nationwide digital cellular network coverage for all Telguarcl units. Teiard's Corriunic,ttop Ceflr. ! JLothilantndjDrovide.. . .'. - ............... Advanced Reliability Features SMS backup to reduce false alarms, providing self-tests using SMS if GPRS fails Aitothicelf-tests with central te (II CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (736-o_-1402:0109,'Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LAA02, TG7LA00I, TG7LAA0I, TG7LA002,rG7LAF01' TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF0I, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division