Loading...
HomeMy WebLinkAbout5909 SEA OTTER PL; 200; FPC2020-0012; PermitPERMIT REPORT (L'City of Carlsbad Print Date: 01/05/2021 Permit No: FPC2020-0012 Job Address: 5909 SEA OTTER P1, #200, CARLSBAD, CA 92010-6675 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090820900 Valuation: $961,594.25 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Applied: 01/23/2020 Issued: 02/05/2020 Finaled Close Out: 05/21/2020 Inspector: Final Inspection: Project Title: Description: AIRSPACE TECHNOLOGIES -FIRE ALARM TI (40 DEVICES) Applicant: FPContractor: RED HAWK FIRE & SECURITY RED HAWK FIRE AND SECURITY CA LLC JOHN STASUKEVICH P0 BOX 310702 920 S ANDREASEN DR, # 102 BOCA RATON, FL 33431-0000 ESCONDIDO, CA 92029-1936 (760) 233-9787 (760) 535-0045 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FC2o2j- oo FIRE ALARM SYSTEM TENANT IMPROVEMENT SUBMITTAL For AIRSPACE TECHNOLOGIES O 5909 SEA OTTER PLACE, 2ND FLOOR, CARSLBAD, CA 92010 Submitted By: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 PROJECT INFORMATION SHEET PERMIT NUMBER: INSTALLING CONTRACTOR: Red Hawk Fire .& Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 Phone: (760) 233-9787 S CONTRACTORS LICENSE: C-10/C-16 #713099, 11/30/20 PROJECT MANAGER: John Stasukevich PROJECT NAME: AIRSPACE TECHNOLOGIES PROJECT ADDRESS: 5909 SEA OTTER PLACE, 2ND FLOOR, CARLSBAD, CA 92010 SCOPE OF WORK: 'FIRE ALARM SYSTEM TENANT IMPROVEMENT January 22, 2020 Re: Airspace Technologies . 5909 Sea Otter Place, 2nd Floor, Carlsbad, CA 92010 Fire Alarm System Tenant Improvement Red Hawk Fire & Security is pleased to submit the following equipment for your approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is fully- sprinklered. OTY. MODEL NO. DESCRIPTION C.S.F.M. 1 BPS 10A Remote Booster Power Supply 7300-1657:0229 1 SIGA-PD Smoke Detector 7272-1657:0331 1 SIGA-5B4 Standard Detector Base 7300-1657:0120 15 SIGA-CT1 High Power Control Relay Module 7300-1657:0121 16 GCF-VM Strobe Only, Ceiling Mount 7125-1657:0219 3 GCF-HDVM Horn Strobe, Ceiling Mount 7125-1657:0202 5 GCF-HDVMIET Horn Strobe, Ceiling Mount, High Candela 7125-1657:0202 . Notes: 1. The existing Fire Alarm Control Panel and new Booster Power Supply are manufactured by EST and are compatible with all new devices. Respectfully Submitted, RED HAWK FIRE & SECURITY 0 AEA 76-91-E Vol. 13 7300-1657: 0229 Standard Features Allows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identify wiring or internal faults Standard EDWARDS keyed lockable steel cabinet with re- movable door 110 and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 EDWARDS Catalog 1> Power Supplies and Accessories LIFE SAFETY ' INCIDENT MANAGEMENT Remote Booster Power Supplies BPS6A, B' Overview S The Booster Power Supply (BPS) is a UL 864, 9th Edition listed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NAGS) or auxiliary power for Mass Notification/ Emergency Communication (MNEC), as well as life safety, security, and access control applications. The BPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the BPS can support batteries totaling up to 65 ampere-hours in an external enclosure. The BPS has four Class B (convertible to two Class A) NACs. These can be activated in one or two groups from the BPS's unique dual input circuits. The BPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The BPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 9th edition IUO)oQFire Alarm Systems UL636 (ANET, UEHX7) Holdup Alarm units and Systems UL609 (AOTx, AOTX7) Local Burglar Alarm units and Systems UL294 (ALVY, UEHX7) Access Control Systems UL365 (APAW, APAW7) Police Station Connected Burglar Alarm Units and Systems UL1076 (APOU, APOU7) Proprietary Burglar Alarm System Units UL1610 (AMCXI central Station Alarm Unit ULC-5527 (UO)0<C) control Units, Fire Alarm (Canada) ULC-5303 (AOT7) Local Burglar Alarm Units and Systems (Canada) C22.2 No. 205 Signaling Equipment (Canada) S Page 1 of 4 DATA SHEET E850050125 Not to be used for installation purposes. Issue I. Dl D2 D3 D4 D5 D6 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) Application The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. it is listed for indoor dry locations and can easily be installed where needed. Dimensions D50 001 Top View Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the BPS can still be activated upon command. A separate AC Fail contact is available on the BPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VOC (filtered-regulatec) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. BPS NACs can be configured for a 3-3-3 temporal or continuous output. California temporal rate outputs are also available on cer- tain models. This makes the BPS ideal for applications requiring signaling rates that are not available from the main system. In addition to the internally generated signal rates, the BPS can also be configured to follow the coded signal rate of the main Wire routing system NACs. This allows for the seamless expansion of existing NACs. The BPS enclosure has mounting brackets for up to three Signa- ture modules to the right of the circuit board. Power-limited wiring area Engineering Specification Supply, where needed, EDWARDS BPS Series Booster Power Supplies (BPS) that are interconnected to and supervised by the main system. The BPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The BPS battery compliment shall be sized to match the require- ments of the main system. The BPS shall be capable of supervis- ing and charging batteries having the capacity of 24 ampere-hours for Mass Notification/Emergency Communication (MNEC), life safety and security applications, and the capacity of 65 ampere- hours for access control applications. <<The BPS shall be capable of installation for a seismic com- ponent importance Factor of 1.5.>> The BPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- vided with automatically restoring overcurrent protection. The BPS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. BPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, California rate. Fault conditions on the BPS shall not impede operation of main sys- tem NAC. The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Route AC supply through these knockouts only (Nonpower-limited and supervised) Notes 1. Maintain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL, FPLR, or FPLP cable per NEC. 121 Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxiliary power. [3] Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. 0 Page 2of4 DATA SHEET E850050125 Not to be used for installation purposes. Issue 1 Data in from previous device or Signature controller 12 V Security Security EOL icty device ~f !d:ev i Ece monitoring device Typical Wiring Single or cascaded booster anywhere on a notification appliance circuit Existing NAG end-of-line resistors are not required to be installed at the booster's terminals. This allows multiple boosters to be driven from a single NAG circuit without the need for special configurations. NAC circuit I 10 next signaling NAC Circuit device, booster, or EOL resistor DD nTD NAG output #1 Fire Alarm NAG output #2 Control Panel NACoutput#3 NAG output #4 D - C Booster Power Configuring the Booster for Multiple CC1 (5) modules using the AC Power Fail delay operation*. BPS's sense inputs Notification appliance circuit (NAG) IIIIjI'jUL listed Notification appliance circuit (NAG) UL listed EOL 15KW Notification appliance circuit (NAC) UL listed Notification appliance circuit (NAG) UL listed EOL 15 kG E0L47 kG CG1(S) module [1][3] 00 I Data in from 14_... Data out to previous device next device or Signature controller *me Booster supports AG Power fail delay Data out to of three hours via its trouble contact when next device dip switch SW2-6 is on. All other troubles are reported to supervising module or panel without delay via Sense inputs. II L 47 K 11E-Ji4-1 109 GG1(S) module .0 0 GG1(S) module 00 [3] Security and access BPS ° 24V NAG1/ + AUX1 - NAG2/ + CDc12 AUX2 - NAG3/ + AUX3 - NAG4/ + MIYA - To next device or end [11 Disable the BPS's ground fault jumper (JP3) Page 3of4 DATA SHEET E850050125 Not to be used for installation purposes. Issue I LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Requires installation of sepa- rate battery cabinet. BPS supports batteries greater than 24 Amp hours for access control applications only. For earthquake anchorage, including detailed mounting weights and center of gravity detail, refer to Seismic Applica- tion Guide 3101676, Approval of panel anchorage to site structure may require local AHJ, structural or civil engineer review. Specifications Model 6.5 amp Booster AC Line Voltage 1 2OVAC or 220-240VAC 50/60Hz 120VAC or 220-24CVAC 50/60Hz 390 watts 580 watts Notification Appliance 3.0A max. per circuit @ 24Vdc 3.0A max. per circuit @ 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 1 O max total all NACs Trouble Relay 2 Amps @ 30Vdc Auxiliary Outputs Four configurable outputs replace NACs 1, 2, 3 or 4. as auxiliary outputs and 200 mA dedicated auxiliary. (See note 2.) Input Current (from an existing NAC) 3mA @ 1 2Vdc, 6mA @ 24Vdc Btiterrinternal pervisory Current itz&.+ 35 mA for each circuit set to AUX or78tGt'1nternaIAlarm Signature Mounting Space Accomodates three two-gang modules. Maximum Battery Size 10 Amp Hours (2 of 12V1OA) in cabinet up to 24 Amp hours with ex- ternal battery cabinet for fire and security applications; up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing @ 32°C Temperature Rating 32° to 120°F (0° to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, California rate, 3-3-3 temporal, or follow installed panel's NAC. (See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL, ULC, CSFM Model BPSCM provides selection for California rate, in place of temporal. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Description Shipping Number Wt. lb (kg) BPS6A 6.5 Amp Booster Power Supply 13 (5.9) BPS6AC 6.5 Amp Booster Power Supply (ULC) 13(5.9) BPS6A/230 6.5 Amp Booster Power Supply (220\ 13(5.9) BPS6CM 6.5 Amp Booster Power Supply with California rate 13(5.9) OtW 10 Amp Booster Power Supply 13(5.9) BPS1 OAC 10 Amp Booster Power Supply (ULC) 13(5.9) BPS1 OA/230 10 Amp Booster Power Supply (220' 13 (5.9) BPS1 0CM 10 Amp Booster Power Supply with California rate 13(5.9) Related Equipment 12V6A5 7.2 Amp Hour Battery, two required 3.4 (1 .6) 12V1 OA 10 Amp Hour Battery, two required 9.5 (4.3) 3-TAMP Tamper switch BC-1 EQ Seismic Kit for BC-1. Order BC-1 separately. See note 3. BPSEQ Seismic kit for BPS6A or BPS1 0 Booster Power Supplies. See note 3 BC-1 Battery Cabinet (up to 2 - 40 Amp Hour Batteries) 58 (26.4) BC-2 Battery Cabinet (up to 2 - 17 Amp Hour Batteries) 19 (8.6) 12V1 7A 18 Amp Hour Battery, two required (see note 1) 13 (5.9) 12V24A 24 Amp Hour Battery, two required (see note fl 20 (9.071 12V40A 40 Amp Hour Battery, two required (see notes 1, 2) 32 (14.5) 12V50A 50 Amp Hour Battery, two-required (see notes 1, 2) 40(18.14) 1 2V65A 65 Amp Hour Battery, two required (see notes 1, 2) 49 (22.2) Page 4 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue I EDWARDS Catalog Intelligent Initiating Devices 0 ME GIUiilliii6iiiöIOies LIFE SAFETY INCIDENT MANACEMEN1 Intelligent Smoke Detector Like all Signature Series detectors, the SIGA-PD is an intelligent device that gathers analog information from its optical sensor, converting this data into digital signals. To make an alarm decision, the detector's on-board microprocessor measures and analyzes sensor readings and compares this information to historical data. Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. 00~' ;ot 0000 nook S853 * Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Next Generation Optical Smoke Sensing Technology Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration Uses Existing Wiring Automatic Device Mapping Up To 250 Total Signature Addresses Per Loop Two Levels of Environmental Compensation Two Levels of Dirty Detector Warning Twenty Pre-Alarm Settings Five Sensitivity Settings Non-Volatile Memory Electronic Addressing Identification of Dirty or Defective Detectors Automatic Day/Night Sensitivity Adjustment Bicolor (Green/Red) Status Led Standard, Relay, Fault Isolator, and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification S Overview • The Signature Series SIGA-PD optical smoke detector brings advanced sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while environmental compensation helps reduce maintenance costs. Page lof4 DATA SHEET E850010646 Not to be used for installation purposes. Issue 1.2 Application The SIGA-PD detects extremely small particles of combustion and triggers an alarm at the first sign of smoke. Thanks to its high-performance forward-scattering reflective response technology, the photoelectric smoke sensor responds quickly and reliably to a wide range of fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings. Compatibility The SIGA-PD detector is compatible only with the Signature Loop Controller. Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square Self-locking tab electrical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing LED Indicator centers. See mounting base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitivity measurement can also be transmitted to the loop controller. A sensitivity report may be printed to satisfy NFPA sensitivity measurements, which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Accessories Detector mounting bases have wiring terminals that are accessible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-5B4, SIGA-RB4, and SIGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4 inch square box only. SIGA-AB4G/T/LF SIGA-SB SIGA-113 SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SlGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - Signature Series sounder bases are designed for use where localized or group alarm signaling is required. SlGA-AB4G bases provide sounder capability to Signature Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire-plus-CO mode. SIGA-AB4GT bases provide sounder capability to Signature Series smoke and heat detectors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator. S SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and heat detectors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator. The SlGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page 2 of 4 DATA SHEET E85001 -0646 Not to be used for installation purposes. Issue 1.2 The isolator operates as follows: - a short on the line causes all 1 isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A 0 IN S circuit nearest the loop DATA>j controller, the isolators close to provide the next isolator dawn DATA IN (+) the line with power From Signature Controller or Previous Device - when the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. DAT OUT (-) DATA IN t> DATA OUT () From signature Controller To Next Device or Previous Device Term Description I Nomisftrj Open CONTACT RATING 2 DATA IN/OUT (+) 1.0 Amp @ 30 VDC 3 Common )Pilot Duty) 4 5 6 7 DATA IN Not Used Normally-Closed DATA OUT ).) Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 Audible Sounder Bases, Fire Mode (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. AB4GL AB4G, AB4G-LF sounder bases 5 Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. /1 Standard Detector Base, SIGA-SB, SlGG$4 This is the basic mounting base for EDWARDS Signature Series detectors. The SIGA- LED Remote LED is supported by this Base. Term Description 1 Not Used 2 DATA IN/OUT (+) 3 Not Used 4 DATA IN (.) 4 Remote LED 5 Remote LEO )+) 6 Not Used 7 DATA OUT (-) JRemot OUT -i DATA IN 1+1 DATA OUT 1+) From Signature Controller To Next Device or Previous Device SIGA-AB4G, SIGA-AB4G-LF: Volume Setting Default = High Cut/remove jumper for low dB 24 Vdc in - From power supply or previous base + Data in - From Signature Controller or previous device Output Mode Default = Fire Cut/remove jumper for Fire plus CO SlGA-AB4G: Tone Setting Default = Temporal Cut/remove jumper for Steady 0 SIGA-AB4GT: Not used 24 Vdc out -b + To next base or EOL relay Data out to next Signature device Jumper cuts EU) DATA. DATA- DATA. six, xiv- OUT ta Susan Isolator Detector Base, SIGA-113, SIGA-I134 This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. Warnings & Cautions This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safeguards with the local fire protection specialist. This detector does not sense fires in areas where smoke L cannot reach the detector. Smoke from fires in walls, OUT(-) roofs, or on the opposite side of closed doors may not reach the detector. DATA OUT Photoelectric detectors have a wide range of fire-sensing To Next Device capabilities and ares best suited for detecting slow, Term Description smoldering fires. 1 Not Used - DATA IN/OUT (+) In Canada, install according to CAN/ULC-5524 Standard for 4 Not Used the Installation of Fire Alarm Systems, CSA C22.1 Canadian 5 Not Used DATA OUT Electrical Code, and the local authority having jurisdiction. 7 Not Used Relay Detector Base, SIGA-RB, SIGA-RB4 L This base includes a relay. Normally Open or Normally Closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel. The relay base does not support the SIGA-LED Remote LED. Page 3 of 4 DATA SHEET E85001 -0646 Not to be used for installation purposes. Issue 1.2 Dimensions WAH 1906 / LIFE SAFETY & INCIDENT MANAGEMENT Contact us... 2.3 1 16 Email: edwards.fire@fs.utc.com / , NdjN 00 Web: edwards-fjre.com .410 I i_r- I i 1016 Corporate Park Drive Mebane, INC 27302 9186 ED WARDS is registered mark in the United States and other countries. © 2018 United Technologies Corporation, All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC pA Smoke Sensitivity Range ULJULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuraion Vibration level 10 to 35 Hz, with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft/mm (0 to 20 m/s) Wall mounting 12 in. (305 mm) max. from ceiling Compatible bases See Ordering Information Compatiblee detector testers Testif ire 1000, Testifire 2000 Operating environment 32 to 120°F (0 to 491CI. 0 to 93% RH. noncondensina Constructicn High Impact Engineering Polymer, White - Storage temperature -4 to 140°F (-20 to 60°C) is Environmental compensation Automatic Agency Listings CANIULC-S529, UL 268, 268A, CSFM, FM approved Ordering Information Catalog Ship Wt. Description Number lbs (kg) Intelligent Optical Smoke Detector 0.4 (0.16) Accessories SIGA-SB Detector Mounting Base - Standard 4-inch Detector Mounting Base c/w Trim Skirt SlGA-RB Detector Mount Base SlGA-RB4 4-inch Detector unting Base w/Relay, c/w Trim Skirt 0.2 (.09) SIGA-IB Detector Mount 1+ Page 4 of 4 SIGA-IB4 4-inch Detector Mounting Base wl Fault Isolator, c/w Trim Skirt SIGA-LED Remote Alarm LED (not for EN54 applications) SIGA-AB4G Audible (Sounder) Base for Fire Detectors 0.3 (0.15) SIGA-AB4G-LF Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15) SlGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors 0.3(0.15) SIGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0 (1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleaning Tool DATA SHEET 5001-0646 Not to be used for installation purposes. Issue 1.2 11 iu wAñitiliTh'iililes EDWARDS Catalog t> Intelligent Input-Output LIFE SAFETY . INCIDENT MANAGEMENT Input Modules &*@P-i' SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 SIGA-M JMEA 7300-1657: 0121 I 33424 I Overview The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller dung system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1, SIGA-CT1 HT and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-CT1 HT module operates at an expanded temperature range of 32 OF to 158 OF (0 00 to 70 00) for those applications requiring more extreme environmental temperature variation. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. SlGA-CT1HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. S The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tem- perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO mother- boards are available. All wiring connections are made to terminal S blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Page lof4 DATA SHEET E850010241 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SlGA-PRO Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. nstallation SIGA-CT1, SIGA-CT1 HT and SIGA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SlGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm') wire size. Compatible electrical box Wall plate, white • 5 (1-gang) is LEDs LED viewing ports * •'\ OS" SIGA-MCT2: mount the UlO motherboard inside a suitable ED- WARDS enclosure with screws and washers provided. Plug the SIGA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UIO Motherboard 6-32 Self-tapping screws jPlug-in (1-110) >CaptivE Module screws #6 Flat washers —cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code" The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two per- sonality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SlGA-CT2/MCT2 modues only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personalty Code 1) - Assign to one or both circuits. Configures either circL:it A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configu-es either circuit A or B or both for Class B normally-open dry cortact initiat- ing devices such as Waterilow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latch 3d at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACT.VE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is chsed. The active condition is latched at the module. S S S Page 2of4 DATA SHEET E850010241 Not to be used for installation purposes. Issue 1 UL/ULC Listed 471<0 EOL Green LED (Normal) 161 f DATA lN(+))- ( ' DATA OUT DATA IN From Signature controller To Next Device or Previous Device SIGA-CT2 I I Typicol NO Irl5otin4 slJsLc Lktod 47KW EOL Oct. In+ 514n0t Date T Green LED Normal) Rod LED lAcUool AAA 123 4 T814 N, rqulrel Ir TS I WN,- LIJ No connections orjumper settings reqoirod for MCT2. SIGA-MCT2 I UL/ULC Usted 471(0 EOL TB2 Style B (class B) 8 7 6 5 AAA s 's Red LED © 0 (Alarm/Active) Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1 .0mm2), and #14AWG (1 .50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size I Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) - #14 AWG (1.50mm2) #12 AWG (1.50 mm2) Typical N.C. Initiating Device Typical NO. Initiating Device INPUT 1 INPUT 2 4,000 ft(1 219 m) A AAStyle B (class B) -< TB2 fl 8 7 UL/ULC Listed • • 47KDEOL Red LED Green LED (Alarm/Active) © © # - (Normal) TBI { DATA IN(+)> I I 01 DATA OUT (+) DATA IN(-) > . DATA From Signature controller To Next Device or Previous Device A 3t', SIGA-CT1 HT NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2) wire; Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc @ 350 pA The SIGA-Ul06R and the SlGA-Ul02R do not come with TB1 4. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility .These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and 10 Series control panels. Page 3 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Catalog Number SIGA-CT1HT I S1G)CT1 SIGA-CT2 I SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Standby = 396pA; Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates UI02R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to 70°C) to 0 0 to 49 C) Storage Environment -4°F to 140°F (-20°C to 60°C): Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA CSFM Ordering Information Catalog Description Ship Wt. Number lbs (kg) OF4 Single Input Module - UL/ULC Listed 0.4(0.15) SIGA-CTHT Single Input Module High Temperature Operation ULJULC Listed 0.4 (0.15) SIGA-CT2 Dual Input Module - ULJULC Listed 0.4 (0.15) SIGA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0 (0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6) SIGA-U102R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) SIGA-U106R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) SIGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module . Mounting Plates 7.0 (3.1) SIGA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4 (0.15) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP21_ Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4of4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 S EDWARDS Catalog t> Strobes, Horns, Bells, Chimes Cot Qtalujqnlit~ LIFE SAFETY INCIDENT MANAGEMENT FIRE Field Configurable Ceiling Strobes ~L.ERT G8Fis FCC 0 @ IVIEA CE 7125-1657: 0219 Lj Overview S Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required cross" pattern, significantly exceeding UL-1 971 and ULC-5526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear amber or blue lenses. They are ideal for applications that re- quire differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - Amber and blue lens models available. See Ordering Information for details. Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals — ideal for long runs or existing wing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971 -listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULO listed for ceiling or wall use Page 1 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear, amber or blue lenses with optional ALERT markings, they are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/8 (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 6.8" dia. (173 mm) ____ _- -__- -- - 1.0" (25 mm) 0.60(15 mm) Light output (effective cd) Percent of UL rating versus angle Percentage of rated output 0. Angle— Horizontal and vertical outputs reflect the same pattern. Field Configuration Depending on the mode?, Genesis ceiling speaker-strobes have multi-candela output / Candela switch (see ordering information). The output / setting is changed by simply opening the device and sliding the switch to the desired setting. The strobe does not have to be removed to change the output setting. 7 The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. go fl To listed To next fire alarm appliance, control I end-of-line I or return to OJC,J I panel ++ I control ______ I equipment Page 2 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2 S Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. .Standard output models (mA) High Output models (mA) UL 1 "15" or "D" "30" or 75j or "B" or "A" or or 'C' or "B" "177"or "A" Rating RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 109 151 281 318 330 392 502 565 16Vfwr 131 194 379 437 432 518 643 693 Standard output models (mA) High output models (mA) Typical '9''or "D" 'or "C" "75'° or "B" "95" or "A" "95" or "D" "115' or "C', '150" or "B" "177" or "A" Current RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 94 140 273 325 333 392 499 551 20 Vdc 74 108 205 244 259 303 378 429 4Vdc. CZ63 198 194 212 245 306 342 33 Vdc 48 70 124 139 155 180 211 236 16Vfwr 126 187 368 403 484 570 673 724 20Vfwr 108 156 281 333 380 438 537 604 24Vfwr 97 139 240 270 318 361 434 484 33Vfwr 89 119 197 214 245 269 308 338 Light Output Standard output models High output models Switch Settings (candela) Switch Settings (candela) Lens Listings Lens Listings color Standard Setting Setting Setting Setting color Standard Setting Setting Setting Setting Clear UL 1971 95 cd 75 cd 30 cd 15 cd Clear UL 1971 177 cd 150 cd 115 cd 95 cd Amber UL 1638 82 cd 65 cd 26 cd 13 cd Amber UL 1638 155 cd 130 cd 100 cd 82 cd Blue UL 1638 40 cd 31 cd 12 cd 6 cd Blue UL 1638 80 cd 78 cd 59 cd 48 cd Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear). Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Suitable for Mounting indoor wall or ceiling applications. Wire Connections Screw terminals: 418 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating Indoor: 32-120' F (0-49° C) ambient temperature; 0-93% relative humidity. environment A listings/ Agency iS ings Meets or exceeds year 2004 UL requirements for standards UL1638 and UL1971 and Canadian requirements for standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final approvals Rule. CSFM, MEA, FM. Strobe output rating Clear: UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Amber: CAN/CSA-022.2 No. 205, CAN/ULC-5526, UL 1638: selectable 13/26/65/82 cd (GCW*VMA), 82/100/130/155 cd (GCW*VMHA) Blue: CAN/CSA-C22.2 No. 205, CAN/ULC-S526, UL 1638: selectable 6/12/31/40 cd (GCW*VMB), 48/59/78/80 cd (GCW°-VMHB) Strobe operating GC-VM series strobes: non-coded, filtered 16-33 Vdc voltage or unfiltered 16-33 Vdc FWR. b h Strobe as rate GC-VM series strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely within 10 milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Synchronization Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer to • specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. Synchronization SlGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Sources BPS6A, BPS1 OA, APS6A, APS1 OA, iO Series, Fireshield Plus 3,5 and 10 zone. Add Gi M for Gi -CVM &G1 -HDVM devices only. Page 3 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2 Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric - candela value. ECS/MNS appliances are selectable by A, B, C, or 0 designations. LIFE SAFETY & INCIDENT MANAGEMENT Model Housing I Marking I Lens Strobe Ship Wt. Life safety Arrnliances (c/w runnina man icon screen orinted on housina GC-VM White None Clear Selectable 15, 30, 75, 0r95 cd 1.8 lb. (0.82 kg.) White 'FIRE" GCFR-VM Red 'FIRE" GC-VMH White None Selectable high output 95, 115, 150, or 177 cd GCF-VMH White "FIRE" ECS/MNS Appliances (no runninci man icon on housinci GCWA-VMA White "Alert" Amber Selectable A, B, C, 0 1.8 lb. (0.82 kg.) GCWA-\/MC Clear GCWN-VMA None Amber GCWN-vMB Blue GCWN-VMC Clear GCWA-VMHA "Alert" Amber Selectable high output A, B, C or D Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN- VMBH Blue GCWN-VMHC Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2017 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2 [1 EDWARDS Catalog Strobes, Horns, Bells, Chimes aEUiitii1e LIFE SAFETY INCIDENT MANAGEMENT Field One or more patents pending. Cei l ing orn —Strobes MEA CE 7300-1657: 0202 S218 Overview Standard Features S Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required 11 cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page 1 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 Application Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping oersons is approximately 100 cd. EDWARDS recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front Of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to 412 AWG (0.75 mm2 to 2.5 mm2) wiring: Horn/strobes are interconnected with a single pair of wires as shown below. Polarity alarm next fiance, I-of-line eturn to Dntrol iipment Note: Strobes must have continuous voltage. Dimensions 6.8 dia. +(25 (173 mm) m) 0.60(15 mm) S . Page 2 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue I High dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 1 85 87.8 1 95.7 1 98.7 Low dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83, 88.8 92.4 33 Vdc 1 80.9 1 85.9 1 91.8 1 95.1 Percent of UL rating versus angle Per Cent or iii RaCng 90' a. Current Draw GC-HDVM Temporal Horn-strobe: High S UL 15 cd 30 cd Rating RMS RMS dB Setting 75 cd RMS 95 cd RMS GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 cd 115 cd 150 cd 177 cd RMS RMS RMS RMS 16 Vdc 147 190 316 372 341 399 506 570 16 Vfwr 189 253 417 451 487 578 670 711 GC-HDVM Temporal Horn-strobe: High dB Setting GC-HDVMH High cd Temporal Horn-strobe: High dB Setting Typical 15et 30 cd 75 cd 95cd. 95 cd c115 177 cd Current RMS Mean RMS Mean RMS Mean RMS Man RMS Mean RMS Mi RMS Man RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 2dc. 80 108 101 185 180 212 220 217 252 2,49p 304 ,61 341 338 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 16 Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20 Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 24 Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 33 Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 GC-HDVM Temporal Horn-strobe: Low dB Setting GC-HDVMH High cd Temporal Horn-strobe: Low d8 Setting Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411 24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332 33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232 16 Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 20 Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 24 Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264 33 Vfwr 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used 'mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output Light output - (effective cd) Notes •1. All values shown are dBA measured at 10 feet (3.01 m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3of4 DATA SHEET E850010559 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwa rds-fire .com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications H ousing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear) Mounting North-American 4" square box, 2 1/8" (54 mm) deep (indoor wall or ceiling applications only). Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-S525 & ULC-S526, year 2004 UL Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies with UL1480. All horn-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional Gi M Genesis Signal Master) Strobe output rating UL 1971, UL 1638 ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchroiization Sources G1M-RM, SlGA-CC1S, SlGA-MCC1S, BPS6A, BPS10A GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON,.½ sec OFF, ½ sec ON, l½sec OFF, then repeat cycle Ordering Information Catalog Housing Ship Number Color Marking Description Wt. lbs (kg) GC-HDVM White None E+1DVM White FIRE" Genesis Ceiling/Wall Horn-Strobe with selectable 15, 30, 75, or 95 Cd output 0.82 GCFR-HJVM Red "FIRE" GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe FjO'MH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories Gi M-RM Genesis Signal Master - Remote Mount (1-gang) 0.2 SIGA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) White Field Configurable Ceiling Horn-Strobes may be ordered witn or without optional FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. Page 4 of 4 DATA SHEET E85001-0559. Not to be used for installation purposes. Issue I STATE FIRE MARSHAL LISTING SHEETS S 0 UO!S!fiçJ 5WJ00WI5U3 &JI-J iojeuipioo w0J50Jd '0TI11SV3 ainva :AB pazuoqny ozoz oE aunt' salldx3 &l.!S/7 6 M 'O Ainr :penssl eiea S ieqlo JO/pU8 suoijorulsui U0!1eIIOSU! 1931S elep s994S!I Oj JO49 O!J91!J3 UO!05UI io slueww!nbw Iouo!lej9do joaJoo ,c4U3A ol p35fl 3q IOU pnoqs 6U!1S!I SIqJ p9jS!I W9! 3111 JO uOijopu3wwoo3i Jo juawasiopue u IOU si 6u!js! 51qJ swiep Aue jo uO1Ie04U3n 1u9pu3d3pu1 ue @New jou sop jnq ejop J01110 joipue sns3J p9M9!A3J 5014 J.JO1S 6UU39U!6U2 GJ1J LAIdSO IUe3!Idde 91]j Aq poll!WqflS OIOP IeO!UIP3I uodn P3Seq S! 6U!1S!I S!L1I OW 0 -6 -L 6: L 69 1-00SL IcIJeWJod SiO9p J0j IOflUBLAJ U04OflJ1SUI UO!10IIBTSUI S001S!I 01 JOJOH T!flDJ!3 03Ue!Idde U0!TeOlJ!TOU 0141 PU0X0 01 ST!Ufl IOJWOO WJ0O aiij eqi4edwoo pes!I Aiaieedes seolsil 111IM osn JOJ seiiddns JeMod jalsooq eowei so pesi leqel In pue 6uqej 'Jeqwnu japow ewou seesr] UO!1O!ps!JflF 6U!A014 AT!J0L11fle 0141 01 eqedooe iouuow 0 Ui pue seoueuipjo pue sepoo eqeoidde uoqonJTsui uoqellelsui pelu!Jd seesi ql!M eouepj000 UI ZH 09 ZH 09 A 01/A 0 suo!leiep!SUoO IeU0!1eJed0 pue U0Qd!JO5ep pnpod PeI!eTeP JOJ 188115 010P SeelSil 01 J848 AiddnS JM0d IcJB!I!XflV 0SN0LSdV pue VQSdV VV09SdV 0Z/V9SdV V9SdV SI8P0LAJ 5O!IddflS JOMOd jalsooq OTOIUOJ W30Sd PU 'VV39Sd9 0Z/V0ISd 0CN9Sd8 V0kS4 'V9Sdg SIOPOLAJ woo OTflSj4J0A0UO3epU0qJ s-os (6) X0 SP-65L (6) JOAOUO3 iieer :10eTU03 SOTOTS p8T!Ufl zozi7cuoivapejo 'AeM)1Jed JOTUO3 UMOI 9969OUI UO!T0J0dJ03 S0O!J0W'' 'T!j°°S & 8JIj C)_Ln 40 Uo!s!A!a V ScIHVMG S3IA0 3SILAd/S1IH0SS33V IINfl 1OJINO3 VJeIV1V 381A -- OOSL 1. 40 4. °6°d 33IAI2S ONIISI1 VlVlOOId 9NPISI1 S1VII31VIN ONimins - ONIN33NION3 3H1=1 1VHSl YIN 3HIJ JIVIS AH1 =10 33I±10 N0I13101d 3NUT AI1S310d dO 1N3INThVd3 VIN0dI1V3 :jc S ONI)ll YIN :NOI1V11V1SNI :9j :NIS3O :jsI1 A10OJ1V3 °N ONIISI1 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. .16574033:1i Page 1 of 2 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: ModelsjQ-PD, *SlGl.PD *KlpD and *KIRPD Analog addressable photoelectric smoke detectors.*Model SIGI-PD is similar to Model SIGA-PD except for isolation circuitry. *Model KI-PD is identical to Model SIGA-PD except for trade name. *Model KIR-PD is similar to Model SIGA-PD except for control panel compatibility. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Models SIGA-PD and SIGI-PD are under the Edwards brand. *Models Kl-PD and KIR-PD are under the Kidde brand. APPROVAL: Listed as analog addressable photoelectric smoke detectors. *Model Kl-PD is for use with listee's Models VS1, V52 and V54 (CSFM No. 7165-1657:0244); VM-1 (CSFM No. 7165-1657:0309) fire alarm control units. *Models SIGA-PD and SIG[-PD are for use with listee's Models EST3 (CSFM No. 7165-1657:0186); i064, i0500 and i01000 (CSFM No. 7165-1657:0244); EST3X (CSFM No. 7165-1657:0306) fire alarm control units. *Model KlR-PD is for use with listee's Models FX-64, FX-254 and FX-1000 (CSFM No. 7165-1657:0244) fire alarm control units. *Model SIGA-PD is for use with listee's bases: Models SlGA-SB, -5B4, -RB, -RB4, -IB, -1134 (CSFM No. 7300-1657:0120); SIGA-AB4G (CSFM No. 7300-1657:0222); SIGA-AB4GT (CSFM No. 7300-1657:0307) and SIGA-AB4G-LF (CSFM No. 7300-1657:0322). *Model SIGI-PD is for use with listee's bases; Models SIGI-AB4G (CSFM No. 7300-1657:0222); SIG]-AB4GT (CSFM No. 7300-1657:0307) and SIGI-AB4G-LF (CSFM No. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct i operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7272-1657:0331 Page 2 of 2 7300-1657:0322). *Models Kl-PD and KIR-PD are for use with listee's bases; Models KI-ABST (CSFM No. 7300-1657:0222), KI-ABDT (CSFM No. 7300-1657:0307) and KI-ABLT (CSFM No. 7300-1657:0322). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. S S *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listirg is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and,or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION• OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Detector Bases. Base models are as follow: Models 5963B, 5964 B/BR, 624113-002, 624913-001, 6251, 625113-001A, -001, -002, -003, -004, 6251 B-100, -00, -R1 00, -R200 and 6251-2 Models 6251 B-001, -002, -003 and -004 are suitable for releasing device service. Models P-847674-0022, -0024, -0042, -0043, -0044, -0045, -0046, -0047. ModelsS1A-113, -1134, -RB, -RB4, -SB,SB4nd -AB4. *Models KI-IB, -1134, -RB, -RB4, -SB and -5B4. The -RB series are suitable for releasing device service. *Model SlGl-SB and SIGI-5B4. Model AB4G-SB surface mount back box for use with listee's SIGA series sounder bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. *Kl are under the Kidde Brand. SIGA* and SlGl* are under the Edwards Brand APPROVAL: Listed as mounting bases for use with separately listed compatible detectors and fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:120 and 7300-1388:170 *Rev 05-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7Q&12* Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CC1, SIGA-CC2, SCTSlGA-CT1HT, SIGA-CT2, SIGA-CR, SIGA-CRR, SIGA-UM, SlGA-MM1, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCC1, SIGA-MCC2, SlGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SIGA-MP1, SIGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-UIO2R, SIGA-U106 and SIGA-UI06R motherboards. Model CS-SIGA-CC1P releasing module. Models SIGA-CC1S and SIGA-MCC1S Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SlGA-CR2 Control Relay Module. Model SIGA-CT1 HT; Signature Series High Temperature Single Input Module. *SIGACRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev 01-11-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VM, Ct'MCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model GIM-RM (CSFM Listing No. 7300-1657:201) sync module, which.may employ Model SIGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct S operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 'l of 1 CATEGORY: 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST" G1-HV15, -HV30, -HV60, -HV-75, G1-H0V15, -H0V30, -HOV60, -H0V75, -HOV110, GIF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIRF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH,vG GCFR-HDVM, GiF2HDVMl/l, G1-HDV1575, G1R-HDV1575, Gi F-HDV1575, and Gi RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33Vdc/Vfwr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, Gi R-HDV1575, G1F-HDV1575, G1RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd S 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, Gi R-HDV1575, Gi F-H Dvi 575, Gi RE-H Dvi 575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC..HDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division