Loading...
HomeMy WebLinkAbout2005 COSTA DEL MAR RD; ; FPC2017-0383; PermitPEER'4]IT REPORT Icr City of Carlsbad Ftr1eiae:r1miit Print Date: 04/11/2022 Permit No: FPC2017-0383 Job Address: 2005 COSTA DEL MAR RD, CARLSBAD, CA 92009-6816 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 12/27/2017 Valuation: $0.00 Lot #: Issued: Occupancy Group: Project #: Finaled Close Out: 03/29/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: THIRD LA COSTA CONDOMINIUM OWNERS ASSOCIATION FIRE ALARM TI Applicant: FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS JOHNSON CONTROLS SECURITY SOLUTIONS LLC LLC - DO NOT USE MALCOLM DCOSTA 3870 MURPHY CANYON RD, # 140 3870 MURPHY CANYON RD, # 160 SAN DIEGO, CA 92123-4403 SAN DIEGO, CA 92123-4403 (561) 226-8210 (619) 805-5300 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov Highlighted Set Cut Sheets and CSFM Listing Sheets For: Third la Costa Condominium Owners Association 2005 Costa del Mar Road Carlsbad, California 92009 Installer: tqcn Integra ted Security 2023 Chicago Avenue Suite B6 RIVERSIDE, CA. 92507 (951) 244-8686 LIC 4977249 (C-b, C-7) (MS.9200UDLSI(E) Rev 3 I eIIigent Addressable FAJ iith Built-In Communicator i1iIIt1 The Fire-Lite MS-9200UDLS Rev 3 with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS Rev 3 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeedTM mode—Fire•Lite's latest polling technology—for a quicker device response time. LiteSpeed's patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The MS-9200UDLS Rev 3's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, additional secondary ANN-BUS, and increased power for the resettable and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools—the Fire-Lite Upload/Download software kit—may serve as a Service Termi- nal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, AD355 (LiteSpeed), USB port, NAC circuit diagnostics, a new report has been added to the walk- test that lists untested devices, new device types added: audio telephone type code for ACC 25/50ZST, Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACP5 (Fire Alarm Control Panels). DF-60601 Al • Al -60 i3 Fire tietarms by Honeywell Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port upload/download, using PS- Tools. Four (4) Style Y (Class B) NAC circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or LCD-80F, ANN-80 or Legacy ACS Annunciators. ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): - ANN-80(-W) Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module - ANN-RLED Annunciator Module alarms only - ROME Relay Option Module Enclosure ACS/TERM: - ACS Annunciators: Up to 32 Legacy ACM Series annun- ciators (ACM-1 6AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. - Terminal-mode Annunciators: Up to 32 Legacy LCD-80F remote annunciators. DF-60601 Al • 12/07/2010 - Pagel of 6 EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6F. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterf low (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 m.). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable) 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PS-Tools, separately). Upload/ download system programming locally to the MS- 9200UDLS Rev 3 in less than one minute. USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information MS-9200UDLS: 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. 120 VAC operation. MS-9200UDLSE: Same as MS-9200UDLS, except with 240 VAC operation. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style Y (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PK-CD Programming software for Windows®-based PC com- puter (cable not included), available on www.firelite.com. DP-9692: Optional dress panel for MS-9200UDLS Rev 3. TR-CE: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB- 55F for mounting. BAT Series: Batteries, see data sheet DF-52397. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with MS-9200UDLS Rev 3(E). PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming and updating panel firmware. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 or DF-52424 for more information.) Page 2 of 6— DF-60601 Al • 12/07/2010 IPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- sure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD dis- play. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) DNRW: Innovair Flex low-flow non-relay duct-detector hous- ing, with NEMA-4 rating. Watertight. (Order SD355R sepa- rately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0 (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) I DC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. ANN-LED: Annunciator Module provides three LEDs for each MMF-301: Miniature version of MMF-300. Excludes LED and zone: Alarm, Trouble and Supervisory. Ships with red enclo- Style D option. Connects with wire pigtails. May mount in sure (see 0F60241). device backbox. ANN-RLED: Provides alarm (red) indicators for up to 30 input MMF-302: Similar to MMF-300, but may monitor up to 20 con- zones or addressable points. (See DF60241). ventional two-wire detectors. Requires resettable 24 VDC ANN-RLY: Relay Module, which can be mounted inside the power. Consult factory for compatible smoke detectors. cabinet, provides 10 programmable Form-C relays. (See DF- 52431.) ROME: Relay Option Module Enclosure. Provides one ANN- RLY Relay Module already installed. The ROME Series pro- vides mounting space for one additional Relay Module or one addressable Multi-module. (See Installation Sheet PN 53530.) ANN-SIPG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ACM-8RF: Relay module provides 8 Form-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS Rev 3, see the following data sheets (doc- ument numbers) ACM-8RF (DF-51555), ACSIACMSeries (DF- 52378), LDM Series (DF-51384), LCD-80F (DF-52185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. SD355R: Addressable remote test capable detector for use with D355PL or DNR(W) duct smoke detector housings. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fixed high-temperature detector that activates at 190F/88C. AD355(A): Low-profile, intelligent, "Adapt" multi-sensor detec- tor (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D355PL: Innovair Flex low-flow non-relay duct-detector hous- ing. SD355R included. DF-60601 Al • 12/07/2010 - Page 3 of 6 MS-9200UDLS Remote ACC-25/50 SIT) 1 Fire Alarm Microphone Audio Command Control Panel Center 0 .5 SPA Speaker S0355 --- SPC Photo Detector Series Speaker - LCD-80F SPS Adapt ê!ttctor Series Speaker/Strobe - ANN-3D H355/H355R1H355H1 Heat Detector Strobe MDF-300 Dual Monitor Module .. Strobe Power Supply Photofrhermal loin= 1`211 E_[w Strobe MMF-300 Ii , I Monitor Module Multi-Modules CRF-300-6 Six-Relay Control Module P 1 • CMF-300-6 Six-Circuit Supervised Control Module 0MMF-302-6 Six-Zone Interface Module - • MMF-300-10 Ten-Input Monitor Module MMF-302 2-Wire Detector Monitor Module - — D355PL Beam Detector/Beam 355 Duct Detector MS-9200UDLS ADDRESSABLE FIRE ALARM BG-12LXAddressabIe CONTROL PANEL Manual Pull Station CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0' (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0' (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 opera- tion). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a 1313-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a 1313- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 1313-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a 1313-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 1313-6F. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9200UDLS Rev 3, see the following data sheets (document numbers): A0355 (DF-52324), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-60379), CMF/CRF Series (DF-52 130), CP355 (DF-52383), D355PL (OF- 52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 Series!MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), 50355/5D355T (DF-52384). 2) Legacy 300 Series detection devices such as the CP300/CP350, 5D300(7)/ 5D350(7) and older modules such as the M300, M301, M302, C304, and BG- IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard LiteSpeed protocol. Please consult factory for further information on previous 300 Series devices. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. Page 4 of 6— DF-60601:A1 • 12/07/2010 DF-60601:A1 • 12/07/2010 - Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits.......................................1 Addressable device capacity..........................................198 Programmable software zones.........................................99 ACS Annunciators ............................................................32 ANN-bus devices..............................................................16 Electrical Specifications AC Power: MS-9200UDL5 Rev 3:120 VAC, 60 Hz, 3.0 amps. MS-9200UDLS Rev 3E: 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require an external battery charger such as the CHG- 75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) for a total of four Style Y (Class B) or with an optional ZNAC-92 module con- verts to four Style Z (Class A) NACs. Maximum signaling cur- rent per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documentation and Fire-Lite Device Compatibility Docu- ment for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each output. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAG 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.12 (.30 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 16.65° (42.29 cm.) wide x 5.20' (13.34 cm.) deep. Trim Ring (TR-CE): 22.00' (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F NFPA Standards The MS-9200UDLS Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9200UDLS Rev 3 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S624 FM approved CSFM: 7165-0075:0208 MEA: 120-06-E For ULC-listed version, see DF-60599. FireLite® Alarms® is a registered trademark of Honeywell International Inc. Wheelock® is a registered trademark of and ExcederlM is a trademark of Cooper Notification. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IM[ ERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6— DF-60601:A1 • 12/07/2010 ELRs, 4.7K, 1/2W 441 (for Style V wiring) DB9F 2 Programmable Relays & Fixed Trouble Relay ElA232 to printer or Non-supervised relay contacts Contact rating: personal computer 2.0 amps t 30 VDC (resistive) )nonsuervised) 0.5 amps t 30 VAC (resistive) For EbP-listed OR equipment or personal Contacts shown below in computer with FACP normal condition (AC power Upload/Download with no alarm, trouble, or TERM Utility. supervisory activity) IEIA-4851 50 foot maximum to LCD-80F within same room. OR AC Fail Safe Trouble relay switches to the NO position OR during trouble conditions and under toss of all power. Secondary ANN-BU (Factory default relay tpAflflUr)FiO5 Basic System Connections Notification Appilcance Circuits NAC #1. #2, #3, &#4 Style V (Class B) (Supervised. Power-Limited) (Speisal application) 2.5 amps max. per circuit NAC #1 NAC 93 NAC #4 NACI Special Application DC Power Outputs (24 VDC) Nonsupervised. Power-Limited circuits Supervise with a power supervision relay EOLR-1 Nonresettable Power suitable for powering annunciators: Resettable Power suitable for powering smoke detectors. Resettable or Nonresettable Power Jumper selectable by JP6, 24 VDC filtered, { power-limited (1.0 amp maximum). 3 Supervision required. Nonresettable or Reset/able Power Jumper selectable by JP4, 24 VDC filtered, ( power-limited (1.0 amp maximum). 1 Supervision required. TB8 no opuan souR-fl) Remote Synchronization Output programming) Supervised, Power-Limited circuits (2 24 VDC fltered (0.35 arno maximum), - + - + upervisory Alarm* Trouble Requires a 4.7 Kohm End-of-Line Resistor no no 01 4.... 1. W.. > ml O c e .., ................... 0"' - - 77 0 =7 JP7 To disable ground fault :.:irw o-rr.o.o. soc .0w cc ic 'co. 0 detection, remove Jl4 ilt jumper/shunt from JP7. 1= Importanti Removing Ground Fault Disable Convert NAC circuits from Style V 'Class B) Jumper JP7 voids to Style Z ltlass A) Cutthis jumper UUNFPA Style/Class ____________ with the ZNAC-a2 to enable identifications for converter module. Supervisory jumper JP7 only with 1&2 (JP4) and 3&4 (JPB) OS 4XtMF is the approval of the AHJ Resettable or Nonresettabte installed (Authority Having Power. circuits. Remove Configure T8 1, Terminals relay when Jurisdiction). Reset/able Power- jumper I i Nonreseflabte Power- jumper pins 152. Jumpers are installed at/he factory as shown. Transformer 2 Connector 5 lair Transformer 1 Connector [JJ -ii KEYPAD LCD savior' IF AC Power fl (Supervised. y Nonpower-Limited) 0 ,.evas 0 120 VAC, SO Hx, 2.0 amps LJJ fiat KEYBOrRDCONN. 2201240 VAC, 50Hz. 1.2 amps -+ c .ri I 0 0 -Q .iaL]CJ L__J 0 0 o 0 PSI PHONE sac awl Flash Memory Load Enable Switch: UP is normal position for switch, lDOVv1'J position allows to factory software upgrades FF15 SLC Loop (supervised) ! ®!Ii '.:.LLtrE1 Port J12 for local amming using a ,net comrsuter and 5200ud1sbrd.wmf Primary ACSJANN-BUS to Annunciators a (power-limited, supervised) ,Ja r000c00000005_io I Cut this jumper to supervise the 4XTMF when installed J7 JP3 (see J5&J6) Auxiliary Trouble Input (Ci) F/lie TP SEC. ic4oiEr ISO erto disable 24 Off-board pi '1 eyboard Interface DACT Phone Une Jacks 24 VDC, supervised, sounder- J8 ttery charter nonpower-limited, (Canadian an exlemaT 18 AH maximum Applications ger only) B200SR lxi 0.000500 Maximum alarm draw for all Addressable devices ---------------> 0.400000 EOLR-1 I xl 0.020000 I = I x 0.020000 FCPS (Remote Sync) HEM x 0021700 = x = x = x = x = x = x = x = x = x = x = NAC 1 - th . x = NAC2 = NAC3 x NAC4 x Current Draw from TB3 Total Standby Load Total Alarm Load Fire-Lite Alarms Page 2 11/11/2010 nreure tarms by Honeywell MS-9200UDLS Rev.3 Battery Calculation Secondary Power Source Requirements Device iType Standby Current (amps) Secondary Alarm Current (amps) Main Circuit Board) (1) X(0.145000) = )0.145000) x (0.275000) (0.275000) XRM-24B x 0.000000 = x 0.000000 = 4XTMF x 0.005000 = x 0.011000 = IPDACT-2 x 0.093000 = x 0.136000 = IPDACT-2/2UD x 0.098000 = x 0.155000 = ANN-BUS Devices ANN-80(-W) x 0.015000 = x 0.040000 = ANN-LED x 0.028000 = x 0.068000 = ANN-RLED x 0.028000 = x 0.068000 = ANN-RLY x 0.015000 = x 0.075000 = ANN-I/O x 0.035000 = x 0.200000 = ANN-S/PG x 0.045000 = x 0.045000 = ACS Annunciators ACM-8RF x 0.030000 = x 0.158000 = ACM-16ATF x 0.040000 = x 0.056000 = ACM-32AF x 0.040000 = x 0.056000 = AEM-16ATF x 0.002000 = x 0.018000 = AEM-32AF x 0.002000 = x 0.018000 = AFM-16ATF x 0.040000 = x 0.056000 = AFM-32AF x 1 0.040000 = I 1 xi 0.056000 = AFM-16AF x 0.025000 = xj 0.065000 = LDM-32F x 0.040000 = xj 0.056000 = LDM-E32F x 0.002000 = x 1 0.018000 = LCD-80F x 0.025000 = xj 0.064000 = Resettable Power 4-Wire Smoke Detectors I I xl 1=1 I I xl Addressable Devices BEAM355 x 0.002000 = . ) t. tt -. . M . . Hr t2.t4. . it.! M4. fli'tRit 4.. . tt.45. .Ott ..ht -. .- 4 4• . =MMM BEAM355S x 0.002000 = BEAMI224 x 0.017000 = CP355 x 0.000300 = 5D355) (x) (0.000300) L SD355T x 0.000300 = AD355 x 0.000300 = H355) (x (0.000300) = H355R x 0.000300 H355HT x 0.000300 = D350P x 0.000300 = D350RP x 0.000300 =M D350PL x 0000300 = D350RPL x 0000300 = D355PL x 0.000300 MMF-300 x, (0.000400) MMF-300-10 x 0.003500 = MDF-300 x 0.000750 = MMF-301 x 0.000375 = MMF-302 x 0.000270 = MMF-302-6 x 0.002000 = BG-12LX) )x' (0.000230) CMF-300 x 0.000390 = CMF-300-6 x 0.002250 CRF-300 x 0.000270 CRF-300-6 x 0.001450 =IHIF 1300 x 0.000400 = B501BH 2 x 0001000 = B501BHT2 B224RB B224B1 x x x 0001000 0000500 0000450 = = = ................... Fire-Lite Alarms Page 1 11/11/2010 nr-ureALarms by Honeywell MS-9200UDLS Rev.3 Battery Calculation Calculation in Total Sheet l Required TStandby Time fl1 Hours Standby Load Current I X I 1=1 Alarm Load Current (Amps) I x = Total Current Load Multiply by the Derating Factor I I = Total Ampere Hours Required Recommended Batteries: I I Current Draw Check 7MI Fire-Lite Alarms Page 3 11/11/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. (7165-0075:0208) ge 1 o) (çGORY:) (1165 -- FIRE ALARM CONTROL UNIT (COMMERCI) LISTEE: -LITE ALARMS INC.0ne Fire-Life Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev©Honeywell.com DESIGN: Models MS-9200UD andS-9200UDLS addressable control unii)Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *MS9200uDLS panel also suitable for high-rise application for use with Model ECC-501100 emergency voice evacuation panel (CSFM #6911-0075:0226). This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 11-12-13gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 (L]7igExpJ June 3O,2O18) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DISCHARGE CHARACTERISTICS AT 25 C(77- F) U1111lU111111111 011-111-1 ONES • MINIMUM 14,11 UhilllIIIiEiiiuibU•, UUUIlII*UiIIiLuIIlll•U. ulIIHu•luI!1UUUIuIlUU uIIIHlU•IlPIUIIIIIIlUU. • ...uuuii.u.ii11..u1111..: • UIIEiML4H•UIIIIIIUU - I U 3 5 10 20 30 60 U 3 5 10 20 30 rrir In Discharge Time CHARGED ISO ace VOLUME __._-.--.---------------- CHARGED VOLTAGE 60 N 10 aol I., a. -7~,L CHARGING CURRENT Chargeing Time (h) Cycle service life 2L 4 40 DUO 200 600 000 logo 1200 Life (cycle) U POiER ____ KINGDOM IedLead-Acid Batteri) e 12 I Specifications I 77 Nominal Voltage 12V Rated Capacity 18Ah Dimensions Total Height 6.57 inches (167mm) Height 6.57 inches (167mm) Length 7.13 inches (181mm) Width 3.03 inches (77mm) Approximate Weight 11.46 tbs. (5.2kg) Characteristic Capacity 77°F(25°C) 20h rate 18.0Ah 10h rate 16.2Ah 5h rate 15.3Ah lh rate 10.8Ah 15 min rate 7.6Ah Internal Resistance Full Charged Battery 770F(250C) Approx. 18m Capacity Affected by Temperature (20h rate) 1040F(400C) 102% 770F(25°C) 100% 320F(0°C) 85% 5°F(-15°C) 65% Self-Discharge 68°F(20°C) (Capacity after) 3 month storage 90% 6 month storage 80% 12 month storage 60% Max. Discharge Current_77°F(25°C) 270A(55) Terminal T3IT1O Charge (Constant Voltage,250C) Cycle I I 14.5.-14.9V(-24mV/°C) max. current: 5.4 A Float 13.6..43.8V(-18mV/0C) Constant Current flischare Characteristics (A.25C) F.V/TIMIE 5min 10min 15min 30min 60min 3h 5h lOh 20h 9.60V 70.0 45.0 36.0 20.0 12.0 4.47 3.05 1. 73 0.91 10.2V 66. 5 42.8 34.6 19.2 11.5 4.40 3.00 1. 71 0.91 10.5V 62.5 40.2 32.8 18.2 10.9 4.31 2.94 1. 70 0.90 Constant Wattage flischare Characteristics (Watt.212) F.V/TIME 5min 10min 15min 3 Omin 60min 3h 5h 10h 20h 9.60V 781 508 410 229 139 53. 1 36.4 20. 7 11.0 10.2V 742 482 394 220 133 52.3 35.8 20.5 10.9 10.5V 698 453 374 209 127 51.2 35.1 20.5 10.8 DF-52121:A. E-325 (MMF.3qqA) Series! nreuTeALanTis MDF-300 (a Addressable Monitor Modules by Honeywell General n n Four different monitor modules are available for Fire•Lite's intelligent controls to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a mere 1.3' (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it's monitoring. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style 0) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTm is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF-300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on LiteSpeed sys- tems, 01 —99 on CLIP systems. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The MMF-300 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in exist- ing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit 9 67S9 0 8 4 11 1 s' 2 rF-300 and MMF-302 6 52 4 ONE 10 AU DR ESS 09 0 0 0095 detail of MDF-300 - note 08 1 2',l3 "ones" addresses are II'17 15514 2 TENS0 O 0, 2, 4, 6, 8 onlYJ!6 3 ONES may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. Maximum IDC loop length is 2,500 ft./762 m (20 ohms maximum). MMF-300 OPERATION Each MMF-300 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). 1jF-3OO SPECIFICA TIONS) NominaI oper ngvoltage: 5 to 32 VDC.) (Maximum current draw: 5.1 mA (LEDJ) goperatingcurrent: 400 JA(LEDflash) (L resistance: 47K ohms.) (lem pqrature 32-F to 120 (0Ciö49°C)) Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire FACP. No additional power required. DF-52121 :A • 6/11/07 - Page 1 016 High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on LiteSpeed sys- tems, 01 —99 on CLIP systems. 1415 0 i ADDRESS 0 12 3 LOOP L._.J 8 76 8 76 TENS ONES I— o uj c o -J -J UJ • -J o The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The MMF-301 can be used to replace M301 module in existing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75' (6.985 cm) wide x 0.5' (1.270 cm) deep. Wire length: 6' (15.24 cm) minimum. MMF-302 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on LiteSpeed sys- tems, 01 —99 on CLIP systems. LED flashes during normal operation (this is a programma- ble option). LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 has a panel-controlled LED indicator and can be used to replace M302 modules in existing systems. MMF-302 APPLICA TIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 OPERATION Each MMF-302 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Requires regulated, resettable 24 VDC power. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style Y) IDC circuits ONLY Class A (Style Z) IDC circuits are NOT supported in any application. MDF-300 SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Page 2 of 6— OF-52121 :A • 6/11/07 Average operating current: 750 pA (LED flashing) EOL resistance: 47K ohms. Maximum IDC wiring resistance: 1,500 ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address "56", then it will automatically assign itself to addresses "56" and "57". The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: CS3705 FM Approved CSFM: 7300-0075:185 MEA:72-01-E NOTE: "ones" addresses on the MDF-300 are 0, 2, 4, 6, 0r8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use Product Line Information the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125' (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. MMF-300: Monitor module. MMF-301: Monitor module, miniature. MMF-302: Monitor module, two-wire detectors MDF-300: Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. Arch itects'!Engineers' Specifications Specifications of these and all Fire•Lite products are available from Fire•Lite. © I CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING \ Face plate for MMF-300, MMF-302, and MDF-300 Mounting Diagrams for standard-sized modules DF-52121 :A • 6/11/07 - Page 3 of 6 Wiring Diagrams The following wiring diagrams are included: MDF-300: Typical dual two-wire Style B initiating device circuit configuration. MMF-301: Typical two-wire Style B initiating device circuit configuration. MMF-300: Typical two-wire initiating circuit configuration, NFPA Style B. MMF-300: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. MMF-300: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). MMF-302: Interface two-wire conventional detectors, NFPA Style B. MMF-302: Interface two-wire conventional detectors, NFPA Style D. CRF-300: Relay control module used to disconnect a power supply. Figure 1 MDF-300 Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits (L&H) TO Next each power-limited to Device FROM Panel 230 iA max. @ 12 VDC max. MONITOR or Previous Device 47KEOL d MODULE Resistor -- Communication Line ELR.47K 32 voc maximum. Twisted-pair is recommended 47K EOL 1 : All shown wiring is supervised and power Resistor I limited . ELR-47K LOOP 0000055 Connect modules to listed compatible Fire-Lite control panels only. ANY NUMBER of UL Listed contact closure devices may be used. DO NOT M/Xfire alarm initiating, supervisory, or security devices on the same circuit. Install contact closure devices per manufacturer's installation instructions, e720mt1 wnt Figure 2 MMF-301 Typical two-wire Style B initiating device circuit configuration. TO NEXT DEVICE I UL LISTED Compatible BLACK IRED MMF-301 Control I Panel 5678910 4/il1 3111 \\ 11112 56789 4 3 213 101514 2 1 IVELLOW - VIOLEThJ 47K EOL INCLUDED g6720.0 .wrot Page 4016— DF-52121 :A • 6/11/07 NOTE: Wiring Diagrams this Page: MMF-300 Connect modules to listed compatible Fire•Lite control ' Any number of UL-listed contact closure devices may be panels only. used. All wiring shown is supervised and power limited. • DO NOT MIX fire alarm initiating, supervisory, or security Install contact closure devices per manufacturers' installa- devices on the same circuit. tion instructions. Figure 3 MMF-300 Typical two-wire initiating circuit configuration, NFPA Style B. (—) FROM Panel Device MONITOR (+) or Previous Device Initiating Device Circuit TO Next —) — NFPA Style B power limi Communication Line 32 VDC maximum. Twisted-pair is 8(a 1 47K EOL 230 pA max recommended. Resistor 615 3 ELR-47K Communication Loss L (optional connection for panels A ADDRESS which support this feature) FUTURE FEATURE 6720wir2 wrof Figure 4 MMF-300 Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. TO Next —) (—) FROM Pane! Device MONITOR (+) or Previous Device OD LE 0,~) Communication Line 32 vc maximum. 8(5 1 terminals8&9 8 & — Twisted air is + recommended. EOL Resistor is internal at 610 3 '- Communication Loss L ADDRESS (optional connection for panels OOP which support this feature) FUTURE FEATURE 6720wo3 wnrt Figure 5 MMF-300 Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). Next (+)TO (—) FROM Panel Initiating Device Circuit (IDC)Device (+) or Previous NFPA Style B, power limited: MONITOR Device 230 pA max. @ 12 VDC max. k Communication Line Series Resistor 32 VDC maximum. — Twisted-pair is + recommended. 47K EOL Resistor Communication Loss ELR-47K r 00 ADDRESS ESS (optional connection for panels iTJ S J 00 which support this feature) FUTURE FEATURE 6720wir4wrrr1 DF-52121 :A • 6/11/07 — Page 5 of 6 NOTE: Wiring Diagrams this Page: MMF-302 and CRF-300 Connect modules to listed compatible Fire•Lite control panels only. Terminal wiring must be power limited. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. DO NOT LOOP wire under terminals. Break wire run to provide supervision of connections. Detectors must be UL listed compatible with module. Install detectors per manufacturers' installation instruc- tions. Power to the interface module must be externally switched to reset the detectors. An CRF-300 relay control module can be used to switch power from a standard power supply; see Fig. 7 below. Figure 6 MMF-302 Interface two-wire conventional detectors, NFPA Style B. TO Next - Device (+) d LMODULE, b 3.9KEOL r111 Resistor [III5 'V 4I (included) A2143.1O I II OOP SS L't c3 e9 FROM Panel or Previous Device Communication Line 32 VDC maximum. Twisted-pair is recommended. (_) Listed Battery Backup 4 switched DC 4 power supply. .- Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. 6720w1,5.wmf Figure 7 MMF-302 Interface two-wire conventional detectors, NFPA Style D. TO Next Device - C 1—) Listed Batte,y Backup 1+) switched DC power supply. Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. 6720w,,6.wrnt 3.9K EOL Resistor (included) required at terminals 8 & 9 A2143.1O cxDcEI FROM Panel or Previous Device Communication Line 32 voc maximum. Twisted-pair is recommended. Figure 8 CRF-300 Relay control module used to disconnect a power supply. TO Device FROM Panel or Previous Device RELAY I CONTROL DCPOWER SUPPLY ku?MODULE 0 Listed for Fire -l--i I Protection Battery (+) 53IF4 LOOP ADDRxSS 6720w1,7.wn,f Communication Line 32 voc maximum. Twisted-pair is recommended. LiteSpeed is a registered trademark of Honeywell International Inc. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFlU1URINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S,A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6016— DF-52121 :A • 6/11/07 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-0075:018 Page 1 of 1 CATEGORY: C7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES) LISTEE: (FIRE-LITE ALARMS INC.;one Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models MDF-300, MMF-301 ,MMF-300 MMF-302, MCF-300pitor_moduleModels CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 (June 30, 2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division tqoa Integrated Secunty Fire Alarm Record of Completion Date: 0 /// Cue?#: Job #: o ____ Customer Name: 11111111111111111111 8806UE00 Primary System #: ' 70 Secondary System #: Address (City/St Representative of Protected Property (Name/Phone): Authority Having Jurisdiction: , _L_c_A r..t_r_-_. _77. Location of As-Built Drawings: Location of Operation and Maintenance Manuals: Location of Inspection & Testing Reports: Location of Control Panel: Primary Telephone #: 7__7 ,C_,ç Secondary Telephone #: Does Tyco have a contract for testing and inspection in accordance with NFPA standard(s)? El Yes El No If no, who?: Inspection Start Date: -, Inspection Frequency: El Annually El Semiannually El Quarterly El Bimonthly El Monthly 0 Weekly System Software Operating system (executive) software revision level(s): (b) Site-specific software revision date: Revision completed by (Name) (Company) (Date) Type(s) of System or Service ,tAFPA 72, Chapter 8— Tyco Central Monitoring Center Means of transmitting signals from the premises to the central station: (Check all that apply) Digital Alarm Communicator El McCulloh El Multiplex El One-way Radio El Two-way Radio LI Other: -_c•__ Means of transmission of alarms to the public fire service communications center: c 1c1 1D _4' _ System locations: o NFPA 72, Chapter 6- Local If alarm is transmitted to location(s) off premises, list where received: NFPA72, Chapter 8- Remote Station Telephone numbers of the organization receiving alarms: / _OO -.ci' El NFPA 72, Chapter 8- Proprietary Telephone numbers of the organization receiving alarm: El NFPA 72, Chapter 9 -Auxiliary - Check type of connection: El Local Energy El Shunt 0 Parallel Telephone Telephone numbers of the organization receiving alarm: /_6'2 __ .. cS5 _r~_5 3 If alarms are retransmitted to a public fire service communications center or other, indicate name and telephone numbers of the organization receiving alarm: () - &L1)' jP'5'-L' Indicate how alarm is retransmitted: 7 C I e Record of System Installation (Complete this section after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by ',i, on d12_7///r cludes the devices shown in sections 4 & 5, and has been in service since This system has been installed in accordance with the standards as shown below: C.NFPA 72,Chapters EYI' Q4' "3 '4 LVE( L-6 U,7 ,8 0'9 -10 El 11 (Check all that apply) , NFPA 70, NationalE/ectrica/Code, Article 760 '..fV1anufacturer's Instructions AHJ or OtheSource:—._(rAM__9i ' - _,- ,.64 Signed )ate: Organization: ?C Reprinted with permission from NFPA 72 ® 2002, National Fire Alarm Code®, Copyright® 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. @2012 Tyco Integrated Security. All rights reserved. (06/12) . (p. 1 of.3) Control Panel tqco Integrated Security Fire Alarm Record of Completion, cont. 8806UE00 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 106.2.3, is attached All operational features and functions of this system were tested by / /A e .r date And found to be operating properly in accordance with the requirements of: NFPA 72, Chapters 1 a,2 '3 ll'4 IJ'5 3'6 Er7 E38 Iö '10 J 11 (Check all that apply) D"NFPA 70, National Electrical Code, Article 760 [5 Manufacturer's Instructions l'HJ or Other Source:,e,O#, Y , Signed: )Uate: Organization 4. Signaling Line.Circ its Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity 45 Style / Class / 5. Alarm-Initiating Devi -) ) ces and Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): / Quantity (_• Style Class (5 Manual Manual stations Non-coded Coded Transmitters Addressable Combination manual fire alarm and guard's tour coded stations Automatic Coverage: (Check all that apply) El Complete El Partial El Selective El Non-required Enter quantities and eck if th devices are addressable .7" Smoke detectors X Ion Photo /7O) X Addressable Duct detectors Ion Photo El Addressable Heat detectors T RR FTIRR RC ,Addressable Sprinkler waterfiow indicators: Non-coded Coded Transmitters El Addressable The alarm verification feature is U Disabled Enabled , changed from seconds to seconds.- Other (list): 7,,k'7)_,(.)A/e ( C _47 2 ,- 6. Supervisory Signal-Initiating Devices and Circuits GuardsTour: El (a) Coded stations El (b) Non-coded stations El (c) Compulsory guard's tour system comprised of transmitter stations and intermediate stations. Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. (Check if provided.) SprinklerSystem: El Valve supervisory switches El Building temperature points El Site water temperature points El Site water supply level points El Other supervisory function(s) (specify): Electricfirepump: El (e) Fire pump power Fire pump running Phase reversal Electric-driven fire pump: El (h) Selector in auto position El (i) Engine or control panel trouble El (j) Fire pump running Electric-driven generator. El (k) Selector in auto position El (I) Control panel trouble El (m) Transfer switches El (n) Engine running Reprinted with permission from NFPA 72 ® 2002, National Fire Alarm Code®, Copyright © 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. @2012 Tyco Integrated Security. All rights reserved. (06/12) (p. 2 of 3) Control Panel tqca Integrated Security Fire Alarm Record of Completion, cont. 7. Annunciator(s) Quantity: .k' / Type: /2 4/X/ c ) III II I0 11111 101 llhII 1111 Il0 lID II 8806UE00 Location(s): / .c ,t' 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 - Emergency Voice/Alarm Service Quantity of voice alarm/alarm channels:: - Single: Multiple: Quantity of speakers: Quantity of speakers zones: Quantity of telephones or telephone jacks attached to the system: Types and quantities of notification appliances installed: Bells With Visible: (d) Chimes With Visible: Speakers With Visible: (e) Other: With Visible: Horns ('X /3) With Visible: (f) Visible appliances without audible: 9. System Power Supplies (a Fire Alarm ControLPanel: Nominal voltage: /2 Current rating A Over-current protection: Type: Current rating A Location: /•J 7 ,CL A2 ..'9 1 £ ,00 Secondary (standby): Storage battery: /,?t/cA. Amp-hour rating: I<PA Calculated capacity to drive system, in hours: (24) (60) Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency system used as backup to primary power supply: Emergency system described in NFPA 70, Article 700 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviatidnfrom the referenced NFPA standard(s) are: Customer Commnts: Customer Na m6: Signature: Print Name Date Tyco Represe'ntative Name:)A /j 2/f 3/2f/iature: ? 22 '7-::/.---- Print Name Date Upon completion of the system s satisftosy te t(s) witnessed (if required by the Authority Having Jurisdiction): J Repres tive:_ ->4gnature: /AU Print Nam Date i, jrJc-<k çr. Telephone #: Reprinted with permission from NFPA 72 ® 2002, National Fire Alarm Code®, Copyright © 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. ©2012 Tyco Integrated Security. All rights reserved. (06/12) (p. 3 of 3) Control Panel TELULAR® Meets UL 864 requirements for sole or dual path communications technology Supports virtually all alarm formats for universal panel compatibility Connects to your central station's PSTN or IP receivers Increases your RMR while saving your customers money The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system, replacing all of the landlines your customers currently dedicate to their master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. Furthermore, each month they will pay you instead of the local telephone company for the communications path. For each landline they replace with aTG-7FS, their monthly communications bill decreases while your RMR increases. ci ]Ii1PJ. ___________________ Landline Landline TG-7FS Not (5 min Necessary Supervision) La ndline dl Cellular TG-7FS Not (Daily Supervision) (5 min Supervision) Necessary Landline Other TG-7FS Not $$ $$ (5 mw Supervision) Necessary - flhifU iuii.1JjI iiD l By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. When installed with multiple communications technologies, such as DACT, it is acceptable to supervise the cellular communication path just once daily. For existing installations, all landlines can be swapped for a single TG-7FS because of the new five minute supervision mode. ;mit power 1.0-2.0W mum aflowable) - nt consumption A (stand-by) 1w 't'JtI . -- -: 4; 1rjjrii i1rj q1IL(* LJ1j rk'/•!1I.tJ Biti' rj!i Alarm Panel I Th Cellular with TG-7FS Network Telu tar Communication Center 400 Fire Department Central Station Telguard TG-7FS: Ensuring Commercial Fire Alarm Transmission Without a Landline Telular Corporation Atlanta, GA 30339 USA 2727 Paces Ferry Road, SE 1-800-229-2326, Option 5 Suite 1-800 www.Telular.com NFPA LISTED INTERNATIONAL Copyright ©2010Telular Corporation, all rights reserved. Specifications subject to change. Drawings may vary from actual equipment supplied. 122010Rm,A CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-1402:0110) tage 1 of 1) (CATEGORY:) (ioo -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES] LISTEE: crLULAR CORP.322Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju©telular.com DESIGN: Models LV001 *TG7LVA01 *TG7LVF01 and TG-KlT1jgital cellular communicator) (y)Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04072017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Pvt operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 (Listing Expires) (June 3O,2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 65 DISCHARGE CHARACTERISTICS AT 25 C(77 F) UUuuiuiU•iuiLJiuiiiiUU. UIIIEHII•UIIIIII•U .0 I 10 00 JU CU .0 1U 20 30 c-c0 Discharge Time lao CHARGED l 2.00 VC CHARGED VOLTAGE 61 200 2.00 10 CHARGING CURR ENT Chargeing Time (h) Cycle service life Deohace 20150% G000a,0000pt 50% D ON00020lX 7777- 200 400 600 800 000 1200 Life (cycle) POiER KINGDOM ealed Lead-Acid Batteries) Specifications Nominal Voltage 12V Rated Capacity 7Ah Dimensions Total Height 3.98 inches (101mm) Height 3.74 inches (95mm) Length 5.94 inches (151mm) Width 2.56 inches (65mm) Approximate Weight 4.52 lbs. (2.05kg) Characteristic Capacity 77°F(25°C) 20h rate 7.00Ah 10h rate 6.50Ah 5h rate 5.95Ah lh rate 4.20Ah 15 min rate 3.15Ah Internal Resistance Full Charged Battery 770F(250C) 25m Capacity Affected by Temperature (20h rate) 1040F(400C) 102% 770F(250C) 100% 320F(0°C) 85% 50F(-150C) 65% Self-Discharge 680F(200C) (Capacity after) 3 month storage 90% 6 month storage 80% 12 month storage 60% Max. Discharge Current_77°F(25°C) 105A(5s) Terminal TI J2 T2 Charge (Constant Voltage,250C) Cycle I I 14.5-14.9V(-24mV/°C) max. current: 2.1 A Float 13.6-13.8V(-18mV/°C) Constant Current Dincharg Characteristics (A.25'C) 4.8 ii F.V/TIME 5min 10min 15min 30min 60min 3h 5h lOb 20h 9.60V 27.0 18.0 14.0 8.40 4. 70 1.73 1.15 0.71 0.37 10.2V 25. 7 17.1 13.4 8.06 4.55 1.70 1.13 0. 70 0.36 10.5V 24.2 16.1 12.7 7.66 4.35 1.65 1.10 0.68 0.35 Constant Current iliachara Characteristics (Watt.2 °C F.V/TIME 5min 10min 15min 30min 60min 3h 5h lOh 20h 9.60V 301 203 160 94.2 54.4 20.6 13.8 8.52 4.43 10.2V 287 191 153 90.4 52. 7 20.2 13.6 8.40 4.33 10.5V 270 180 145 86.0 50.4 19.6 13.2 8.17 4.21 Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2Y4deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information SIGNALING LISTED ACE-Il (FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals &AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. IS09001 Space (6 Electronics Inc. 7] W 10 800.486.1723 Toll Free Made ISA. REGISTERED sa!om ' 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 No Excuses, Just Solutions! ED0549 LT10559 Rev.D 1/2 kS PACE AGE E/ ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-1 Connector Property Information Minimum Required 0000n,enlatton (SIG-Furl) CO_V/tn.____________ Cetilficatlons and Approvals 200/00(0' 16.1 System installation Conttactor: ,. vaoreonosvvosv 20reos.o .00.2cnlc*naa000soo PrIl 00.0022 eM.u.svC.0,ttnodu.Wo. ou.2520'roo,,00000.nou.v000 16.5 Authority Having Jurisdiction: n2Vl toll/au. c2020.oac0002aaa.a, .,v.O•*00.PeC..d/.0a.v.0O2o(.. .v,ou.soavaos005,roay.oe,,000.sea va/C v 2,0220 .c,eovoaroaa0moua.,a20gu.00o20at7&S.MhAO 05,21 oval,.,,, _______________ ,20v,00(S,.CO22T,.,cslv,v,vvv,thay.Cmt,,501, Ba C-rn flu. _______________ II Con7fl.2,00nao.anno,0210221 Eqalpn,nnt infore,atian 2005(o0125v0.os, Sa.a.O.nO,WCCrolro 60cv0,000na.a 00,0., 0201aa 00.4M.t?0, 02012(00-2 1110644 nro.l Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED) SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! LSD35q(A) Series (Addressable Photoelectric (Smoke _Detectors ) ']jt1 The SD355(A), SD355T(A), and SD355R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire-Lite's Addressable Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indica- tion. Remote LED annunciator capability is available as an optional accessory, PN RA100Z(A). The SD355R(A) is a remote test capable detector for use with D355PL(A) or DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: 01 - 99 with MS-9200UD(LS), and 01 - 159 with MS-9600UD(LS). ARCHITECTURE Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. MECHANICALS Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0' (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). OTHER SYSTEM FEATURES Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. DF-52384:D • E-160 8 FII LITeALarmS by Honeywell S0355(A) in B2IOLP(A) Base OPTIONS Remote LED output connection, PN RA100Z(A). Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. SD355(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation 5D355(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class B) wiring. SD355R(A) mounts in a D355PL(A) or DNR(A)/DNR W duct detector housing. Operation Each 5D355(A) series detector uses one of 99 possible addresses on the MS-9200UD(LS) and up to 318 (159 on each loop) on the MS-9600UD(LS) Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the 5D355(A) series has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar cham- ber, the 5D355(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DF-523840 • 2/11/2015— Page 1 of 2 Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200UD(LS) or MS- 9600UD(LS) addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200UD(LS) or MS-9600U D(LS) for record keeping. Wolage range: 15-32 VDC (peaNJ lStandby current: 300 pA @_4 —VD-C-) ILED 6.5 mA © 24 VDC (latched "ON") (AWeIocity: 4,000 ft/mm. (20 rn/sec.) maximum. (Size: 2.1(5.33 cm) lgh; base determines diameter) - B21OLP(A): 6.1 (15.5 cm) diameter. - B501(A): 4.1' (10.4 cm) diameter. - B200SR(A): 6.875' (17.46 cm) diameter. - 8224RB(A): 6.2' (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for S0355(A): 0°C to 49°C (32°F to 120°F); for SD355T(A): 0°C to 38°C (32°F to 100°F). SD355R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C-49°C(32°F- 1200F). Relative humidity: 10% - 93%, non-condensing Listings Listings and approvals below apply to the SD355(A), SD355T(A), and SD355RT(A) detectors. In some cases, cer- tain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1059. ULC Listed: 51059. CSFM: 7272-0075:0194. MEA: 243-02-E. FM approved. Product Line Information NOTE: °A" suffix indicates ULC Listed model. SD355: Addressable photoelectric detector; B21OLP base included. 50355A: Sames as S0355 with ULC Listing; B21OLPA base included. 5D355T: Same as SD355 but with thermal element; B21OLP base included. SD355TA: Same as SD355T with ULC Listing; B21OLPA base included. SD355R: Remote test capable addressable photoelectric detector for use with a D355PL(A) or DNRA'DNRW duct detector housing; B21OLP base included. 5D355RA: Same as 5D355R with ULC Listing for use with a D355PLA or DNRA duct detector housing; B21OLPA base included. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF-60059. B21OLP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B350LP(A) profile, or to convert older high-profile bases to low-profile. F1101313: Bulk pack of F110; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3- 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR213: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. BCK-200B: Black detector covers for use with 5D355(A) only; box of 10. WCK-200B: White detector covers for use with 5D355(A) only; box of 10. FireLite® Alarms is a registered trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. FNINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52384:1) • 2/11/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. L272-0075T01) Page 1 of 1 CATEGORY: (7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC) LISTEE: (FIRE-LITE ALARMS lNC.9)Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models 5D350, SD350T,(D35)SD355R*, 5D355T and AD355photoelectric type smoke) fdetectorsJ Model SD350T and 5D355T has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models 5D355 and SD355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-11-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 3S (June 30, 2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52385:D • E-710 ("355A Series FureLITeALarms (IntlI.nnt Adrhk) ~Thermal Detectors)by Honeywell General The Fire-Lite Alarms H355(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors provide open- area protection and are intended for use with Fire-Lite's addressable Fire Alarm Control Panels (FACPs). The H355(A) and H355R(A) sensors provide fixed tempera- ture alarm detection at 135°F (57°C). The H355R(A) sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute. The H355HT(A) is a fixed high-tempera- ture detector that activates at 190°F (88°C). These thermal detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory, the RA100Z. Features SLC loop: Two-wire SLC loop connection. Unit uses base for wiring. Addressing: Addressable by device. Rotary, decimal addressing: 01 - 159 with MS-9600 series, 01 - 99 with MS-9200 series. Architecture: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identifica- tion. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. Operation: Factory preset at 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise triggers at 15°F (8.3°C) per minute for the H355R(A). 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. Visible LEDs 'blink" every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. Low standby current. H355(A) in B2IOLP(A) Base 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA100Z remote LED annunciator. Flanged surface mounting kit. Installation H355(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white fire-resistant plastic. The H355(A) Series plug-in intelligent thermal detec- tors are designed to commercial standards and offer an attrac- tive appearance. Operation Each H355(A) Series detector uses one of 159 (MS-9600 series) or 99 (MS-9200 series) possible addresses on a con- trol panel SLC loop. It responds to regular polls from the con- trol panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimu- lates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The H355(A) Series offers features and performance that represent the latest in thermal detector technology. DF-523850 • 5/17/2013 - Page 1 of 2 Spefications Size: 2.1 (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501 (A): 4.1" (10.4 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Installation temperature: - H355(A), H355R(A): -4°F to 100°F (-20°C to 38°C). - H355H1(A): -4°F to 150°F (-20°C to 660C). Humidity range: 10% to 93% relative humidity (noncon- densing). oIge range: 15 to 32 VDC (Standby current: 300 pA @ 24 VDC (one communication (evgy five seconds with LED blink enabled)j (LED current: 6.5 mA © 24 VDC) LMounting: B210LP() flanged base, included. See T-roductj Line Information: Intelligent Bases" if using a different base. Fixed-temperature setpoint: 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Listings and Approvals Listings and approvals below apply to the H355(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2517. ULC Listed (models H355A, H355RA, H355HTA). CSFM approved: 7270-0075:0195. FM approved. Product Line Information NOTE: "A" suffix indicates ULC Listed model. H355: Intelligent thermal sensor; 135° F (57° C); B21OLP base included. H355A: Same as H355 but with ULC Listing; B21OLPA base included. H355R: Same as H355 with rate-of-rise feature; B21OLP base included. H355RA: Same as H355R but with ULC Listing; B21OLPA base included. H355HT: Intelligent fixed high-temperature thermal detector; 190° F (88° C); B21OLP base included. H355HTA: Same as H355H1 but with ULC Listing; B21OLPA base included. INTELLIGENT BASES NOTE: °A" suffix indicates ULC Listed model. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF-60059. B21OLP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BI-1 series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B350LP(A) profile, or to convert older high-profile bases to low-profile. Fl lOBP: Bulk pack of F110; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. : We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— OF-52385:D • 5/17/2013 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 1 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7270-0075:0195) Page 1 of 1 CATEGORY: (77O-- HEAT DETECTOR LISTEE: (FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models 1-1350,355A)and H355H1(fixedtemperature heat detectors. Models H350R and H355R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: H350, H355, and H355HT 135° F fixed temperature H350R and H355R 15° F rate-of-rise H355HT 190° F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. NOTE: Rev. 05-06-05JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 (Listing (June 3O,2O17) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52013:A • E-100 LBG.1 2LX) (Addressable Manual Pull Station) (a Fre•UTeALarmS by Honeywell AressaII The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACP5). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4 (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanicsms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. (Specif Nol operatiolti4 VDQ Maximum SLC. loop voltage: 28.0 VDC) AaxfrümSLC loop current: 230 p Ce Ambient Temperature: 32'F to 120'F (.0 C to 49 C)) (Relative Humidity 93% + 2%RH(noncondii) at 32 C ± 2°C (90°F ± 3°F) For use indoors in a dry location Installation The BG-1 2LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600, 1 - 99 and MS-9200UDLS, 1 - 50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. DF-52013:A • 02/05/2008 - Page 1 of 2 Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. SB-b: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S711 MEA: 67-02-E CSFM: 7150-0075:184 FM Approved C* I Detail of BREAKAWAY TAB* 14 15 0 1 1 ADDRESS 0 13 2 2 LOOP 10 5 76 6 Back of station without door Terminal Connections: 1 SLC (-); 2 SLC (+) LED RY DECIMAL SWITCHES I * Remove tab to select addresses above 99. Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Flre.Llte is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2008 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. i We cannot cover all specific applications or anticipate all requirements. ENGIRMING & MANUFRTURIN& QUALITY SYSTEMS All specifications are subject to change without notice. Made in the u.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52013:A • 02/05/2008 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. (750-0075:0184) Page 1 of 1 CATEGORY: (L150 -- FIRE ALARM PULL BOXES) LISTEE: (FIRE-LITE ALARMS lNC.0ne Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, G-12LX)BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LA0, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, UT-PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 (June 30, 2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Indoor Selectable- Output Horns,) Strobes, and Horn Strobes for) Wall ADDlications SpectrkertO Advance audible visible notification products are rich with features guaranteed to cut installation times [iI R -- fVrTo mm SWVVbtWeTnSIe mm oTo r and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING 4MEA LISTED 84011 (chimes, horn strobes, horns) APPROVED 3023572 approved MEA452-05-E 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, chime strobes) S5512 (strobes) 7135-1653:189 (horns, chimes) SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box, A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W>< 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7'W x 1.3"D(142mmL x 119mmWx 33 mm D) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7"L x 4.8"W x 0.35"D (145 mm L>< 122 mm W x 9 m D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs F, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data C Xmifl -1) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 ILIIqIT,FTW*ff=, NA NA MM 286 258 1 DC Input 8-17.5 Volts 15 15175 c6-33 Volts) (15 15/75 30 75 95 110 115 (Temporal High) 137 147 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data I 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 Coded Low 74 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes SpectrAlert Advance Dimensions Wall-mount horn strobes SpectrAlert Advance Ordering Information • Wall Horn Strobes 2ñ -Wire Horn Strobe, Standard Cd, Re P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High Cd, Red, Plain P2W 2-Wire Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard Cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White P2WH-P 2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Wall Strobes (cont.) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, "FUEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High Cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" raters to strobes that include 135, 150, 177, and 185 candela settings. T'S 3825 Ohio Avenue • St. Charles, IL 60174 02014 SystemSensor. SYSTEMSYSTEM Phone: 800-SENSOR2 • Fax 630-377-6495 Product specifications subject to change without notice. Vial systemsensar.com for current product information, including the latest version at this data sheet.SENSOR www.systemsensor.com AvoS10201 • 1114 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. -1653:0188) Page 1 of 1 CATEGORY: (7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIREDi LISTEE: (System UnincorporatDiv of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. ___________________________ (Models P2RJ P2W, P2RH and P2WH Horn/Strobes(two-wire_typrectangular enclosure7 Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh sø'A' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 (June 30, 2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SECTION2FIRE ALARM CABLE PART NUMBER AWG CONDUCTOR SHIELDED/ f0VIERALL UNSHIELDED I DIAMETER CONDUCTOR COLOR E JACKET COLOR VOLTAGE I RATING WEIGHT '[ (Ibs)/Unit MARKINGS UPS TEMP PUT 1 I BLACK, WHITE, WHITE I 300v I 18.0 ADT 494469 I 60°C 500 RED, GREEN, LBS 12/C 22 AWG REEL BROWN, BLUE, TYPE FPLP/ ORANGE, YELLOW, CMP VIOLET, GRAY, (UL) PINK, TAN BLACK, RED RED 16.0 ADT 493490 75°C 1000 LBS 2/C 18 AWG BOX TYPE FPLP/ CMP (UL) 8.0 ADT 493490 500 LBS 2/C 18 AWG BOX TYPE FPLP/ CMP (UL) LIGHT BLUE, 60°C 1000 YELLOW 18 AWG BOX E FPLP/ Rj 500 18AWG BOX EFPLP/ (UL) DON'T SEE IT? CALL 1-888-423-8947 ORDERS: PHONE 1-888-423-8947, FAX 847-797-3853 2.20 1 2.21 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7161-1295:0100) Page 1 of 1 CATEGORY: 17161 -- CABLES-FIRE PROTECTIVE SIGNALING) LISTEE: (Comtran Cable, LLC.30A Turner Street, South Attleboro, MA 02703-7714 Contact: Bruce Lamoureux (508) 399-7004 Ext: 245 Fax (508) 399-7360 Email: Bruce.Lamoureux@comtrancorp.com DESIGN: Types FPL, FPLR and .PLPi Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes, NEC Article 760 and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, NEC rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. 6-16-10 MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 (Listing ExpJr (June 30, 2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division