Loading...
HomeMy WebLinkAbout6551 FLAMENCO ST; ; AS160177; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160177 Job Address: 6551 FLAMENCO ST Status: ISSUED Permit Type: SPRINK Applied 6/6/2016 Parcel No: 2153504200 Approved: 7/6/2016 Lot #: 0 Reference No.: Issued: 7/6/2016 PC #: Inspector: Project Title: SANCHEZ RESIDENCE 1,958 SF MODULAR HOME! 440 SF GARAGE! 437 SF PORCH Applicant: Owner: PARAN INC. DBA ROK FIRE PROTECTION SANCHEZ REVOCABLE TRUST 07-09-99 626 MANHATTAN PL #6 LOS ANGELES, CA 21423 MARTIN ST CARSON CA 213-435-9525 Fees ($) Add'l Fees ($) Total ($) Balance ($) 460.5 0 460.5 0 PARAN INC. DEA ROK FIRE PROTECTION 626 MANHATTAN PL. #6 LOS ANGELES, CA 90004 HYDRAULIC CALCULATIONS FOR 6551 FLAMENCO STREET CARLSBAD, CA 92009 FILE NUMBER: DATE: JUN 21, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: 0.05 gpm/sq. ft. AREA OF APPLICATION: 2 HEAD CAL sq. ft. COVERAGE PER SPRINKLER: 256 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 26.7 gpm TOTAL WATER REQUIRED (including hose): 31.7 gpm FLOW AND PRESSURE (@ BOR) : 26.7 gpm @ 16.0 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: ROK FIRE PROTECTION DESIGN/LAYOUT BY: ABU AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT. CONTRACTOR CERTIFICATION NUMBER: 539892 C16 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 38011909 HRS SYSTEMS, INC. AS 160177 6551 FLAMENCO ST SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/21/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS85\3741 DANNY ST.SDF JOB TITLE: 6551 FLAMENCO ST rai 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 N 0 I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/21/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS85\3741 DANNY ST.SDF JOB TITLE: 6551 FLAMENCO ST NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 65.0 55.0 600.0 65.0 31.7 31.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.7 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 5.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.7 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 8.0 K= 4.90 7.0 13.0 2 8.0 K= 4.90 7.8 13.7 TOR 8.0 - - - - 11.0 - - - BOR 0.0 - - - - 16.0 - - - WM1 0.0 - - - - 18.9 - - - WM2 0.0 - - - - 24.9 - - - SOURCE 0.0 SOURCE 31.6 26.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/21/2016 C:\PROGRAM FILES\HRS SYSTEMS\HASS85\3741 DANNY ST.SDF JOB TITLE: 6551 FLAMENCO ST NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (0) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 4.90 13.0 Disch 10.00 150 0.8 2 8.0 7.8 0.0 P1.000 L: 5.0 15.00 0.0 1 8.0 7.0 13.0 1.101 2T:10.0 25.00 0.031 0.8 Pipe: 2 4.90 13.7 Disch 17.50 150 3.2 TOR 8.0 11.0 13.0 1 F1.000 2L:10.0 10.00 0.0 2 8.0 7.8 26.7 1.101 27.50 0.116 3.2 Pipe: 3 0.0 0.0 8.00 150 5.0 BOR 0.0 16.0 26.7 2 F1.000 L: 5.0 5.00 -3.5 TOR 8.0 11.0 26.7 1.101 13.00 0.116 1.5 Pipe: 8 0.0 0.0 15.00 150 3.0 WM1 0.0 18.9 26.7 TOR L1.000 E: 3.0 3.00 0.0 BOR 0.0 16.0 26.7 1.025 18.00 0.164 3.0 Pipe: 9 0.0 Fixed Pressure Loss Device WM2 0.0 24.9 26.7 BOR 6.0 psi, 26.7 gpm WM1 0.0 18.9 26.7 Pipe: 10 Source 0.0 7.00 150 6.6 SOURCE 0.0 31.6 26.7 WM1 LO.750 T: 4.0 4.00 0.0 WM2 0.0 24.9 26.7 0.785 11.00 0.603 6.6 NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 38011909 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.007 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 17.7 ft/sec at pipe 10. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SOURCE under full flow conditions is 64.91 psi compared to the minimum required pressure of 20.00 psi. Notes