Loading...
HomeMy WebLinkAbout6205 EL CAMINO REAL; ; AS140011; PermitCity of Carlsbad Sprinkler Permit Permit No: AS1400II 6205 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 2131001600 Lot #: 0 Status: ISSUED Applied 1/24/2014 Approved: 3/5/2014 Reference No.: Issued: 3/5/2014 PC #: Inspector: Project Title SGCA TI-1ST FLOOR NEW OFFICE PARTITION & 2ND FL MEZZANINE (9) SPRINKLER HEADS MODEL FIFR300 Applicant: FIRE WATCH 437 EL CAJON BL EL CAJON, CA 619-2993473 Owner: MYJJLLC C/O EMILY H M LIN 6205 EL CAM INO REAL CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 268 0 268 0 Bulletin 159 ble Model Fl FR - 300 CD Quick Response Extended Coverage Sprinklers 300 psi 120,7 bar) Rated Model Fl FR - 300 QREC 300 psi (20,7 bar) Rated Sprinkler Types Extended Coverage Pendent (QREC) Extended Coverage Horizontal Sidewall (QREC-9) Extended Coverage Recessed Pendent (QREC) Extended Coverage Recessed Horizontal Sidewall (QREC-9) QREC Pendent Recessed QREC Pendent Product Description Reliable Models F1FR-300 QREC and F1FR-300 QREC-9 pendent and horizontal sidewall sprinklers are high pressure rated automatic sprinklers which can handle a maximum service pressure of 300 psi (20,7 bar). These Models are quick response sprinklers which utilize a 3.0mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables Model F1 FR-300 QREC and QREC-9 sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb contains an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. Other sprinkler parts are made of brass, copper or beryllium nickel. At normal temperatures, the glass bulb contains fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, operating the waterway and allowing the deflector to distribute the discharging water. The temperature rating of the sprinkler is identified by the color of the glass bulb. QREC-9 Horizontal Recessed QREC-9 Sidewall Horizontal Sidewall Application The most common applications for Model Fl FR-300 QREC and QREC-9 Sprinklers will be in fire protection systems for high rise buildings where a quick response rating is required and the pressure entering the sprinkler system is in excess of 175 psi (12 bar). The Use of these sprinklers will provide the opportunity to reduce or eliminate the need for pressure reducing valves. The Reliable Automatic Sprinkler Co, Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 OREC Pendent Model Fl FR-300 Quick Response Extended Coverage Pendent Sprinkler Deflector: QREC Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy Installation Date: Nominal e Thread "K" Factor Sprinkler Approval Temperature Sprinkler Identification Size- Size US Metric Length Organizations Rating Number (SIN) Vi' ½" NPT 5.62 81.0 22' 1,2 135-F (57-C) R5945 (15mm) (R1/2) (56.1mm) 3/4"NPI 8.0 115.3 155°F(68°c) 17/3 l 2.4" 1,2 T 135°F(57°C) R5942 (20mm) (R3/4) (61mm) Model Fl FR-300 Quick Response Extended Coverage Recessed Pendent Sprinkler Deflector: OREC Installation Wrench: Model RC1 Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy Installation Data: Fe oils M 00 Nominal "K" Factor Sprinkler Office Thread Sprinkler Approval Temperature Identification Size Size US I Metric Length Organizations Rating Number (SIN) Vi' ½" NFl 5 62 . I 81.0 2.2" 1,2 135°F(57°c) R5945 (15mm) (R1/2) (56mm) 155°F (68°C) 32, 3/4"NPT 17/ ,.4" 8.0 1115.3 2 1,2 135°F (57°C) R5942 (2C)mm) (2 (R3%) (61mm) Coverage Area Flow Rate Pressure Max. Coverage Area Width x Length K=8.O(1153) K=5.62(81.0) gpm Umin ftxft. bar mxm psi I bar psi 26 98.4 10.6 0,7 I 21.6 I 1,5 16x16 4.9x4.9 33 I 124.9 17.0 I 1,2 I 34,7 I 2,4 18x18 5.5x5.5 40 I 151.5 25.0 I 1,7 I 51.0 I 3,5 , 20x2d 6.0x6.d '"135°F only. (')Refer to escutcheon data table for approvals and dimensions. Model Fl FR-300 Quick Response Extended Coverage Horizontal Sidewall Sprinkler Deflector: QREC-9 Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy Installation Data: Nominal I Orifice Thread I Size "K" Factor Sprinkler! Length Approval I Organizations Temperature Rating I Sprinkler I I Identification I Number US Metric 17/333/e,NPT 80 1153 2.95" 1,2 135°F (57°C) R5962 I (20mm) (R (75mm) ' 155°F (68°C) 2. QREC-9 Horizontal Sidewall ,Model,Fl FR-300 Quick Response Extended Coverage Recessed Horizontal Sidewall Sprinkler Deflector: QREC-9 Installation Wrench: Model GFR1 Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size "K" Factor I I Sprinkler I Length Approval 11 Organizations Temperature 1 Rating°F I Sprinkler I I identification (SIN) US Metric 11/3211 (20mm) 31W'NPT8.0 (R34) 115.3 2.95" I (75mm) I 1,2 135°F (57°C) 155°F (68°C) R5962 "'Refer to Escutcheon Data Table for approvals and dimensions. Coverage Area Rate Pressure Width Coverage DeflectorMaximum DimeFlow x Length Mm. il gpm L/min psi bar ft. x ft. mxm 98.4 10.6 in. 26 0,7 16x16 4.9x4.9 12 29 109.8 13.1 0,9 16x16 4.9x4.9 4-12 102-305 29 109.8 13.1 0,9 16x18 4.9x5.5 4-12 102-305 32 121.1 16.0 1,1 16x20 4.9x6.0 4-12 102-305 36 136.3 20.2 1,4 16x22 4.9x6.7 4-12 102-305 39 1 147.6 23.8 1,6 1 16x24 4.9x7.3 4-12 102-305 PACE OP PITTING roT2 4 To 12 COILING DIMENSION 1/8 TURN SPRING COLLAR UNTIL TIGHT AGAINST I I ROSS. SPRINKLER WRENCH __j II5/I6 2 27/32 014. L RECOMMENDED .l:J___r WALL HOLE I ______ 2) ______ 2 I/4 DIAME1ER E 159P002 I I ADJUSTMENT (2) 48FGO2 Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1FR-300 QREC and QREC-9 Recessed Sprinklers are to be installed as illustrated. The Model Fl or F2 escutcheons illustrated are the only recessed escutcheons to be used with the these sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl FR-300 QREC Pendent and QREC-9 Horizontal Sidewall Sprinklers, use the Model 0 Sprinkler Wrench. When installing Model F1FR-300 QREC-9 Recessed Horizontal Sidewall Sprinklers, use the Model OFR1 Sprinkler Wrench. Use the Model AOl Wrench for installing F1FR-300 QREC Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. Maintenance Model Fl FR-300 Extended Coverage Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damage or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Approval Organizations Underwriters Laboratories Inc. UL Certified for Canada ULI Listing Category Sprinklers, Automatic & Open Quick Response Sprinklers Temperature Ratings Classification Sprinkler Temperature Maximum Ambient Temp. Bulb Color OF °c °F °C Ordinary 135 57 100 I 38 Orange Ordinary 155 I 68 100 I 38 Red Intermediate 175 I 79 150 I 66 Yellow ULI Guide Number VNIV Sprinkler Types Pendent (QREC) Horizontal Sidewall (QREC-9) Recessed Pendent (QREC) Recessed Horizontal Sidewall (QREC-9) 3. Finishes,"' Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome White Polyester Coated White Painted Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other colors and finishes are available on special order. Consult factory for details Escutcheon Data Sprinkler Type Escutcheon Model Approvals Adjustment "A" Dimension Face of Fitting to Ceiling or Wall Dimensions Fl FR-300 OREC Pend Fl 1 2 ~" (19mm) s/i' (19mm) /6" (5mm) to 15 /is (24mm) F1FR-3000REC-9 HSW F2 1,2 31W, (19 3 /6" 1%"(35mm) (5mm) to %"(l8mm) Ordering Information Specify: Sprinkler Model Sprinkler Type. Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. 800.431.1588 Sales Offices Reliable 800.848.6051 Sales Fax 914.668.3470 Corporate Offices w.reliablesprinker.com Internet Address ®Rd paw Revision lines indicate updated or new data. E.G. Printed in USA 01/01 P/N 999990164