Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6260 EL CAMINO REAL; 101; FPC2019-0128; Permit
i1SI1I']iI Lcity of Carlsbad It iii1 ... -- Print Date: 03/30/2022 Permit No: FPC2019-0128 Job Address: 6260 EL CAMINO REAL, #101, CARLSBAD, CA 92009-1609 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2131100100 Track #: Applied: 06/05/2019 Valuation: $143,419.52 Lot #: Issued: 06/17/2019 Occupancy Group: Project #: Finaled Close Out: 11/08/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: OHANA MEDICAL SERVICES -FIRE ALARM TI (EVAC HORN STROBES, STROBES, DOC. BOX) FPContractor: DIALCOM SYSTEMS GROUP P0 BOX 462166 ESCONDIDO, CA 92046-2166 (760) 520-5044 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov q S G Inc. FIRE ALARM SUBMITTTAL FOR Ohana Medical Services Organization, Inc. 6260 El Camino Real, Suite 101 Carlsbad, CA 92009 Submitted by: DIALCOM SYSTEMS GROUP, INC. P.O. Box 462166 Escondido, CA 92046 FPC20I9-0128 6260 EL CAMINO REAL #101 OHANA MEDICAL SERVICES - FIRE ALARM TI (EVAC HORN STROBES, STROBES, DOC. BOX) 2131100100 6/512019 FPC20I9-0128 S G Inc. Dialcom Systems Group, Inc. Phone 760-520-5044 * Fax 760-839-5892 *10 703343 * ACO 7107 PROJECT INFORMATION SHEET INSTALLING CONTRACTOR: DIALCOM SYSTEMS GROUP 1541 SIMPSON WAY ESCONDIDO, CA 92029 CONTRACTORS LICENSE: C-10 703343 PROJECT MANAGER: DENNIS DIAL PROJECT NAME: Ohana Medical Services Organization, Inc. PROJECT ADDRESS: Tri City Medical Center 6260 El Camino Real, Suite 101 Carlsbad, CA 92009 SCOPE OF WORK: 5 Horn strobes, 9 strobes and 1 New Fire Alarm Power Booster REFERENCE: Ohana Medical Services Organization, Inc. Tri City Medical Center 6260 El Camino Real, Suite 101 Carlsbad, CA 92009 Dialcom Systems Group is pleased to submit the following equipment for your review and approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is 100% sprinkled and monitored. QTY MODEL NO. DESCRIPTION CSFM 1 5495 Fire Alarm Power Booster-New 7300-0559:0123 9 SCWL Strobe 7125-1653:0504 5 PC2WL Horn-Strobe 7135-1653:0503 i000)MCIOCT, till on 5495 Distributed Power Module The 5495 Distributed Power Module is them ost powerful and cost- effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor,Gentex®, AMSECO®, and Wheelock. The 5495's switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. Also, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery. The 5495 is the costeffective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that tack cadence capability. CONNECTION TO LOCAL FIRE CONTROL The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kg) end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. 5495 FEATURES & BENEFITS UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class Aor4Class B, or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector! indicator Independent trouble relay AC loss delay option shuts off power to non-essential high-current accessories Like magnetic door holders Built-in synchronization for appliances from System Sensor, Gentex, AMSECO, and Wheelock Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices ANSI Cadence pattern output capability built-in 5495 Technical Specifications SUPERVISION The 5495 supervises a variety of functions including: Low AC power Low battery condition Earth ground fault Auxiliary output power limit condition EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. PHYSICAL Dimensions: 12.25"W x 16"1-1 x 3D (30.88 cm W x 40.64 cm H x 7.62 cm D) ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10°/s - 93°/s non-condensing) ELECTRICAL AC input: 120 VAC at 24 Output: 24 VDC at 64 Current: Standby 75mA; Alarm 205mA Auxiliary power circuit: 1 Notification circuits: 4 Output configuration:2 Class A (Style Z); 4 Class B (Style Y) (1 Class A & 2 Class B) Amps per output circuit: 3.0(6.0 amps total) Notification circuit output: Alarm Current (for typical voltages) drawn from main panel's notification appliance circuits. 12 VDC 6.5 mA 24 VDC One input circuit: 15 mA; Both input circuits: 0 mA No. of inputs: 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9- 32VDC Battery charging capacity: 35.OAH INDICATOR LIGHTS AC power on: Green Battery trouble: Yellow Ground fault: Yellow Aux trouble: Yellow Output troubles (1-4): Yellow ORDERING INFORMATION 5495: Distributed Power Module ACCESSORIES SK-SCK: Seismic Compliance Kit AGENCY LISTINGS UL listed CSFM 7300-0559:123 Meets NFPA 72 requirements ME4429-92-EVolXll OSHPD (CA) OSP-0065-10 Model 5495 Block Diagram Signal Circuit Output Signal I Signal I Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble) For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensor® and Honeywell' are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 3503951 Rev HI 11/17 © 2017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 1 1 OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett©horieywell.com DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and I auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: *Recer. 08-17-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division STEM Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1553:0503 3057383 AVDS868.02 • 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync'Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. I Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AV05868-02 • 12101/2017 • Page 2 UL Current Draw Data 1u®i Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Ii) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 DC Input 8-17.5 Volts 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1KNon-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data pI SQtUtridB Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86B.02 • 12/01/2017 • Pages 2.47 (62.7 mm) 1.37" (34.8 mm) 6.83 d (173n 6.92 diem (175. L-Series Dimensions A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information plvlI !Jtq Wll 1 Ceiling Horn Strobes Ceilinq Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 02017 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change withOut notice. Visit systemsensorcom 1E'ft91' Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, including the latest version 01 this data sheet AVDS868-02 • 1210t/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennetthoneyweII.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WailTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDCIfwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verily correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTE SENsI Indoor Selectable= Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only / Agency Listings SIGNAUN LISTED APPROVED 85512 EM approved except 7125-1653:0604 S4011 for ALERT models 7135.16538603 3057303 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor [-Series can meet virtually any application requirement. The entire [-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the [-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDSE68-02 • 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuif'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans With Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Rang& 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9 diameter x 3.4' high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (RNR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86B-02 • 1210112017 • Page 2 LO/O/?. • 0-89SQAV 88 88 LL mol IeJodwe!-uoN ZH 1-8 8 68 68 iii Ll6u-1 IeJodweI-uoN ZHN V8 L e9 Z8 9L M0] podwaizHA 1.8 9 88 88 88 UH Ie-'odwelzHN V€ S j79 V9 9L MO1 Ie-iodwel-uoN 06 06 98 L16!H IeJodweI-uoN 8 88 89 SL MO1 taodwe± 69 68 j79 LI6IH jejodwo.L 1. 30 30 9p uJOUBd puno UOD!SOd SIIOA SUOA 4041MS CE-9L 1iu1 elva 4nd4nØ punoS pue sauo.LeqojiS WOH 09 6ee 961- I-LI. 091- 1.01. 6L MO1 ialodwei-uoN >11-8 68e 9ge SZ OOZ 6L1. 981. 901. q6!H leiodwej-uoN >11-C o9e 6eF 961. 1-LI- 051. 1-01. 6L MO1leJOdWe1)1LC 68e 9se gee ooe 6L1. 581- 801. LIO!H IeJodwe1N1-C 6 661- eLL 1.51- 1.01- 81 Mollepodwel-uoN 98 t7ge cee 961- 6L1- 981. LOI. 116!H eiOdWol-UON 6Ee 661. eiL 1.91. 1.01- 8L MolleJodWel 99e 179 CZ 961- 6L1. 981. LO1. q6HIeJodWe POLLI. P0091- P391.1. P096 POSL pooc p091. S4IOA CC-91. Indul 69 LI-B L81- 991- 1.81- 89 VS 691. 801- MO1 Ie.1OdWe1-UON >11-C 1-La 6ee Me V91- t7V1- V6 69 ELI. 1.1.1- UH Iei0dW0I-UON >11-C 581- 591- CV I. 89 VS €91- €01- MO1 IeJ0dWeJ.N1-C Zge 6Z76 V81- €91- LV1- V6 69 V91- 1-1-1- q6HieJodWeI>11-C ese 92 OL1- -91- V? 1- 1-L VS 991- 96 MO1Ie1JOdWe±-UON cze ose L81- 991- 1-VI. 06 LL CL1- 901- q6lH 6VZ 1-2 981. 1-91- /81. 1-L VS 991- 96 MoIeJodWej zLe L81. 591- CVL 06 1-L L91- €01- q6!H jejodwai POLLI. P0SL PSI.1. P396 POSL ME P9I. SUOA £E-91. P30E P391. SIIOA 9ZL-8 4fldU130 VS CV et 1401H POPO3ZH>1 1-C VS LV CV —qblH pepo VS 6e Be MCfl IeJodwO1-uoN ZH>1 1-C VS CV e17 U6!H eiodwel-uoN ZH>1 1-C VS ec 6e MO1 eiodwelzH>1 1-C VS 1-V 6€ q6IH IeJ0dw0IzHN 1-C VS ec 6e MO1 IeJodwe1-uoN VS LV CV tI6!H IeJodwe1-uoN VS ec Be MO ieiodwei VS VV 68 I46IH jejodwei BMI 30 30 8P W0Ud puno S4IOA £C-9L SlOA SZL-9 I 2I V9? 9ee V/N LL1- Bee 681- v/N 091- 1.61- 951- v/N 51-1- V91- VC1- v/N 96 Z17 1-1-1- v/N SL 98 C9 €91- 0€ e6ue8 09 1-V L8 51- BlepuBo HMI 30 30 ejaPU83 SIOA C -9L SIIOA 9L1.-9 15I1 ewa Meja 4U3JJfl3 in 2.47" (62.7 mm) 1.37(34.8mm) 6.83' dh' (173 a 6.92" dim (175. L-Series Dimensions A0545-OO A0546-OO Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information piTlI Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box UD Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White YSTEñ!III e2017 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change mi/trout notice. Visit systemuensorcorn for current product information, including the latest version of this data sheet. Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDS868-02. 12101/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135—AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennetthoneyweIl.com DESIGN: System Sensor Indoor 2-wire and *4.wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-82, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division