Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6965 EL CAMINO REAL; 202; FPC2019-0160; Permit
ri1 II1 1 11] I (City of Carlsbad Print Date: 03/30/2022 Job Address: 6965 EL CAMINO REAL, #202, Permit Type: FIRE-Construction Commercial Parcel #: 2150507500 Valuation: $106,973.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: IftU] CARLSBAD, CA 92009-4102 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0160 Status: Closed - Finaled Applied: 07/15/2019 Issued: 08/05/2019 Finaled Close Out: 08/19/2019 Inspector: Final Inspection: Project Title: Description: AUDEO II CHARTER SCHOOL - FIRE ALARM & VOICE EVAC Applicant: ADT MICHAEL HANSEN 3830 CALLE FORTUNADA SAN DIEGO, CA 92123-1825 (858) 254-9126 FEE AMOUNT FIRE New Alarm System $1,265.00 Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov ES-50X Intelligent Addressable FACP with Communicator DF-60953:A (2) FlreLrre®Atarms by Honeywell I '•i:,' __ General The ES-50X is the latest intelligent addressable fire alarm control panel (FACP) from Fire-Lite Alarms. The ES-50X comes with a pre- installed communicator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire-Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cab- inet. Available accessories include local and remote upload/down- load software, remote annunciators, and reverse polarity/city box transmitter (4XTMF). Features Listed to UL Standard 864, 10th edition Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator Optional CELL-MOD or CELL-CAB-FL GSM Central Station Communicator over AlarmNet® Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base Multi-criteria detector (smoke, heat, CO) with programmable response Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterflow selection per module point Alarm verification selection per detector point Maintenance alert warns when smoke detector dust accumulation is excessive One-person audible or silent walktest with walktest log & printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional ES- Tools Programming Utility SLC COMMUNICATION LOOP Supports LiteSpeedTM and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 50 addressable device capacity (any combination of addressable detectors and modules) Compatible with Fire-Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NACS) Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style V (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time DF-60953:A .1/8/2018—Page 1 of 4 Custom English labels (per point) may be manually entered or selected from an internal library file Two programmable Form-C relay outputs 50 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.firelite.com. User interface LED INDICATORS Fire Alarm (red) CO Alarm (red) AC Power (green) Supervisory (yellow) Trouble (yellow) Ground fault (yellow) Battery fault (yellow) Disabled (yellow) Maintenance (yellow) Communication (yellow) Alarm Silenced (yellow) F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge Alarm Silence Drill (Manual Evacuate) Four (4) programmable function keys Reset (lamp test) Product Line Information ES-50X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pie-installed IPOTS-COM communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-50XC, refer to OF- 60954.) FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.firelite.com. CELL-CAB-FL/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the ES-50X. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries & CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mount- ing. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS ANN-80: Remote, red LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See OF- 60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-SIPG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. S0365: Addressable low-profile photoelectric smoke detector. Lite- Speed only. SD365-IV: Addressable low-profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. 5D365T: Addressable low-profile photoelectric smoke detector with thermal sensor. LiteSpeed only. 5D365T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(' duct detector housing. LiteSpeed only. S0365R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(A) duct detector housing. Ivory. Lite- Speed and CLIP mode. H365: Low-profile 135°F fixed thermal sensor. LiteSpeed only. H365-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- Speed only. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365HT: Low-profile intelligent 190°F/88°C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low-profile intelligent 190°F/88°C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices 5D355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. 5D355C0: Addressable, low-profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of-rise option. H355HT: Fast-response, low-profile heat detector that activates at 190°F/88°C. Page 2 of 4— DF-60953:A- 1/8/2018 AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (133501-13 base included). B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D355PL: InnovairFIex low-flow non-relay duct-detector housing; includes SD355R. DNR: InnovairFIex low-flow non-relay duct-detector housing. (Order SD355R/SD365R separately.) DNRW: lnnovairFlex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order 5D355R/SD365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0' (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. BG-I2LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six-fault isolator module. Mount one or two modules in a 1313- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 1313-617 cabinet. SMB500: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed-temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. W-BGI2LX: LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the ES-50X, see the following data sheets (document numbers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-52386), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMFICRF Series (DF-52 130), CP355 (DF-52383), H355 Series (DF- 52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD355/ SD355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(7)ISD350(7) and older modules such as the M300, M301, M302, C304, and BG- IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must beset for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.91K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DF-60953:A • 1/8/2018 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits .•1 Addressable device capacity....................................................50 Programmable software zones.................................................50 Annunciators.............................................................................16 Electrical Specifications AC Power: 120/240 VAC, 50/60 Hz, 3.25 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, super- vised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (ES-50X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum sig- naling current per circuit: 2.5 amps special application, 250mA regu- lated. End-of-Line Resistor: 4.7k ohm, 1,4 watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kL - 22 kL) ELR range. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C132 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C160 - 80°F. NFPA Standards The ES-50X complies with the following NFPA 72 Fire Alarm Sys- tems requirements: - LOCAL (Automatic, Manual, Waterfiow and Sprinkler Supervi- sory). - AUXILIARY (Automatic, Manual and Waterfiow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterfiow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterfiow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) - IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). - CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES-50X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 NOTE: See DF-60954 for ULC-listed model. AlarmNet®, Fire-Lite® Alarms, SWIFT®, and System Sensoi®l are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. Iso 9001 We cannot cover all specific applications or anticipate all requirements. ____ All specifications are subject to change without notice. I I BlCINWIIN & MilNUFRt1IIRIN QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Assembled in the USA www.flrelite.com Page 4 of 4— DF-60953:A • 1/8/2018 Li CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0500 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywelI.com DESIGN: Models ES-50X and ES-200X Addressable Fire Alarm Control Units. Automatic, manual, waterflow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The ES-50X is a compact version of the ES-200X. The ES-50X has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The ES-200X has 198 addressable device capability and 4 Notification Appliance Circuits with 3.oamps total 24VDC output in Alarm expandable to 6.oamps with Model PWRMOD24. The Model IPOTS-COM provides Phone and IP communication. Models ES-50X and ES-200X system components are as follows IPOTS-COM POTS and IP Communicator 4XTMF Transmitter Module ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module ANN-I/O LED Driver Module ANN-S/PG Serial/Parallel Interface Module ANN-RLY Form-C Relay Module ANN-LED Annunciator Module ANN-RLED Annunciator Module CELL-MOD GSM Communicator DP-ES-R Dress Panel Model ES-200X system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: 120/240Vac 50/60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process 01-31-18 gt To This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0075:0500 Page 2 of 2 management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 11 01-31-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ECC-50/1 00(E) Emergency Command Center Firelite's ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications, or both. The Primary Operating Con- soles (POC's)delivers 50 or 100 watts of audio power for distri- bution to up to eight speaker circuits (i.e. zones). The ECC-50/ 100(E) comes standard with a single speaker circuit and a built-in 25Vrms, 50 watt amplifier. A secondary 50 watt ampli- fier (ECC-50W-25/70V) can be added for single speaker circuit backup or to increase system capacity to two speaker circuits and an additional 50 watts of audio power. An optional ECC- CE6 module added to the ECC-50/100(E) will upgrade the system to a maximum of eight speaker circuit outputs. All speaker output circuits can be wired in either Style Y (Class B) or Style Z (Class A) configuration. The ECC-50/100(E) has fourteen field programmable messages (up to 60 seconds each), built-in field configurable pre- and post-announce tone generators and a fully supervised Notification Appliance Cir- cuit (NAC) with 2.0 amps of synchronized NAC power. The ECC-50/100(E) includes three built-in Form-C relay contacts, (AC power, trouble and MNS active) a NAC follower input for triggering the on board NAC circuit and 500mA special appli- cation power. A built-in power supply with switch mode tech- nology delivers operational power to the panel and on board battery charger supports charging up to 26AH batteries (ECC cabinet holds up to 18AH batteries). For fire protection applications, the ECC-50/100(E) is an adjunct (slave) to most UL listed FACPs or as a stand-alone unit for non-fire applications. For seamless integration between fire and mass notification, the ECC-50/100(E) can be activated by the MS-9600(UD) LS and MS-9200UDLS when connected to the ACS/ANN serial communication bus. Activa- tion of the ECC-50/100(E) via other FACP's uses the eight on board Command Input Circuits (CMD's). Two of the eight CMD circuits (CMD 1 & CMD 2) can be individually field pro- grammed for activation by an FACP Notification Appliance Cir- cuit reverse polarity and all eight can be activated by a contact closure. In addition, the ECC-50/100(E) can be activated from a buildings Private Branch Exchange (PBX) with the integral night ring feature. All ECC-50/100(E) programming is done by using a simple, built-in programming utility accessed from any laptop. For added flexibility, the ECC-50/100(E) supports both 25Vrms and 70.7Vrms speaker output operation. By adding a 70V transformer conversion module (ECC-XRM-70V) or an addi- tional 70.7 volt secondary amplifier (ECC-50W-25170V) the system supports 70.7 volt speaker devices. The ECC-50/100(E) can expand in order to accommodate larger or more complex installations. To add more control and increase system capacity, any combination of up to eight exter- nal remote consoles (including the ECC-LOC, ECC-RPU, and ECC-RM) and up to eight distributed audio amplifiers (includ- ing the ECC-50DA(E) and ECC-125-DA(E) can be connected on the external data bus and audio riser data bus to create a fully integrated command center. A fully loaded system sup- ports up to 1100 watts of total audio power and up to 24 speaker circuit outputs. DF-60734:A2 (a FureLITeALarms by Honeywell EmerencY1Y51Evacuati TYPICAL APPLICATIONS Schools Healthcare Facilities Factories Theaters Military facilities Restaurants Auditoriums Places of Worship Office Buildings Dormitories Features UL Listed to UL 2572 Communication (Control Units Mass Notification Systems). Modular design for system flexibility and easy expansion. Removable terminal blocks for ease of servicing and mod- ule replacement. 50 watts of 25V audio power (expandable to 100 watts) RMS. 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for System Sensor, Wheelock or Gen- tex protocols. Optional 70.7V RMS conversion transformer available for the primary amplifier. (Note that speaker wiring continues to be supervised in standby, alarm and when background music is playing with this optional transformer installed). Eight Command Input Circuits to activate messages 1 to 8: - CMD1 and CMD2 are field selectable to be activated from 12 or 24 VDC Notification Appliance Circuits (reverse polarity) or contact closures. - CMD3-CMD8 are activated by contact closures. Speaker Circuits. - Single Style Y (Class B) or Style Z (Class A) speaker Cir- cuit. DF-60734:A2 • 8/22/13 - Page 1 of 8 -Two Style Y (Class B) or Style Z (Class A) speaker cir- cuits (with optional ECC-50W-25/70V Audio Amplifier installed). - Eight Style Y (Class B) or Style Z (Class A) speaker cir- cuits (with optional ECC-50W-25170V and ECC-CE6 installed). ECC-50/100(E) can be controlled by an FACP via the ANN! ACS (EIA-485) link. Compatible FACPs include the MS- 9600(UD)LS and MS-9200UDLS. Integral supervised microphone. Microphone time-out feature which reverts back to pre- recorded message if emergency page exceeds the pro- grammed time. 14 recorded messages. Field-selectable message and custom message recording capability using the local microphone, a USB port, or an external audio input. External Audio Input can be used for background music. Up to 60 second message duration for all messages. Integral tone generators field selectable for multiple tone types. Powered by integral AC power supply or batteries during AC fail. Programmable delay of immediate, 2 hours or 6 hours reporting of AC Loss. Piezo sounder for local trouble. 100 event history log. Three Form-C relays: - AC Power Loss Relay - T131. - System Trouble Relay - TB2. - MNS Active - T133. 500mA (0.5A) Special Application (auxiliary power) output for addressable modules when interfaced with compatible addressable FACPs and End-of-Line power supervision relays. System Status LEDs (refer to "Controls and Indicators" on product manual LS10001-000FL-E). Integral Dress Panel. Optional TR-CE semi-flush trim ring. Any combination of up to eight (8) external remote con- soles: - Optional ECC-RM Remote Microphone (includes cabi- net). - Optional ECC-RPU Remote Page Unit (includes cabinet). - Optional ECC-LOC Local operator console (includes cab- inet). Any combination of up to eight (8) distributed audio amplifi- ers: - Optional ECC-50DA(E) distributed amplifier, 50 watts. - Optional ECC-125DA(E) distributed amplifier, 125 watts. Optional Internal Expansion Modules ECC-CE6: Circuit Expander Module provides connections for up to six Style Z (Class A) or Style Y (Class B) speaker cir- cuits. Circuits are configured through the web-based program- ming utility. ECC-50W-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50!100 power output to 100 watts or can also be used as a backup amplifier. ECC-50W-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50!1 00 power output to 100 watts or can also be used as a backup amplifier. ECC-XRM-70V: 70V Transformer Conversion Module. Con- verts the ECC-50/100(E) primary amplifier to a 70V output. This transformer mounts directly to the ECC-50/100(E) main control board by two metal brackets. Page 2 of 8— DF-60734:A2 • 8/22/13 EEl ECC-FFT firefighter telephonE remote consoles local ECC-LOC ECC-RPU operator console remote paging unit TBI I-I jIl ECC-RM remote microphone nn horns/st ~gj U Internal options ECC-50w-25/70v optional amplifier C Circuit Speaker Circuits )) 0 TB19 TB20 &TB21 001, ECC-CE6 circuit expander charger - J7 [Ii. ECC-50DA 50W ECC-125DA 125W remote amplifier remote amplifier CHG-1 20F charger CHG-75 charger ECC-501100(E) Emergency Command Center (Possible Configurations) DF-60734:A2 • 8/22113 - Page 3 of 8 AU PISYSTPM I ACTTVEI IRESYSTEI 1Di OVERRIDE SPEAKER SV1T!M (jJ9 SPEAKER ZONE 13 IN IIIIIIIE ZONE 1 SPEAKER SPEAKER ZONE 14 i ) ZONE 2 . SPEAKER ZO 3 SPEAKER ZONE 5 PAGE SPEAKER ZONE (j3i SPEAKER ZONE 16 tr -PAGE MICROPHONE TROUBLE SPEAKER ZONE 5 SPEAKER ZONEiT (=9, MESSAGEI SPEAKER ZONE G (I]I) SPEAKER ZONE IS (J) MESSAGE 2 SPEAKER ZONE A (9, SPEAKER, Z0NE19 (9N MESSAGES (]) SPEAKER ZONE N SPEAKER Z044E 20 (=} ' MESSAGE 4 () SPEAKER ZONES SPEAKER ZONE 21 (}II MESSAGES CEO SPEAKER ZONE TO (9, SPEAKER ZOEJE 22 (=9, MESSAGES SPEAKER ZONE II .'.SPEAKER ZONE 23 () MESSAGE 7 (l SPEAKER ZONE I? Li)0 SPEAEKER24 ZON MESSAGE S OIAGE4OSTIZ 0 TROUBLE SLE*4CE 0 SSPSOLA rAT, REMOTE AMPS 0 ) ESABI CONSOLE > GIST MIP I .!)' GROUND FAULT LOCI GIST AMP CHARGER FAULT LOC 2 GIST. AMP SATI[RYFASLT > DINT AMP SAEABUSFAIJI.T > RPU2 GIST AMP 5 > SAC EASEl EPU 3 GOT AMP MAC Ac TM GIST 117P7 > SVSTEMIISOUELE 10. P142 GIST 'SIPS > AUEIOAJSEAFAULI 0> R143 Control and Indicators iIiR(oR11leJ!i All Call • Message Select 1-14 MNS Control • Diagnostic Select System Control • Trouble Silence Speaker Select 1-24 • Console Lamp Test LED Status Indicators (visible with door closed) Fire System Active (green) LOC/RPUIRM 1-8 Active (green) MNS Control (green) Main Console Fault (yellow) System Control (green) AC Power (green) System in Use (green) Ground Fault (yellow) Speaker Zone 1-24 Active Charger Fault (yellow) (green) Speaker Zone 1-24 Fault Battery Fault (yellow) (yellow) OK to Page (green) Data Bus Fault (yellow) Microphone Trouble (yellow) NAG Fault (yellow) Message 1-8 Active (red) NAG Active (green) Message 1-8 Fault (yellow) System Trouble (yellow) Remote Amplifier 1-8 Fault (yellow) Audio Riser Fault (yellow) LOCIRPUIRM 1-8 Fault (yellow) LED Indicators (visible with door and dress panel open) Speaker Volume Control Fault (yellow). Option Card Fault (yellow). Amplifier Over Current Fault (yellow). Product Line Information ECC-50/100: (Primary Operating Console) 50 Watt, 25VRMS single speaker zone emergency voice evacuation system, inte- gral microphone, built in tone generator and 14 recordable messages. ECC-50/100E: Export version (Primary Operating Console) 50 Watt, 25VRMS single speaker zone emergency voice evacua- tion system, integral microphone, built in tone generator and 14 recordable messages. (240 VAC, 50Hz). ECC-CE6: Speaker Circuit/Zone Expander Module. ECC-50W-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/1 00 power output to 100 watts or can also be used as a backup amplifier. ECC-50W-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/100 power output to 100 watts or can also be used as a backup amplifier. ECC-XRM-70V: 70V Transformer Conversion Module. Con- verts the ECC-50/100(E) primary amplifier to a 70V output. This transformer mounts directly to the ECC-501100(E) main control board by two metal brackets. ECC-LOC: Local Operator Console (Complete user interface), Please refer to the data sheet DF-60762 for more information. ECC-RPU: Remote Page Unit Hand held microphone, 14 message buttons. Please refer to the data sheet DF-60761 for more information. ECC-RM: Remote Microphone only. Please refer to the data sheet DF-60760 for more information. ECC-50DA: Distributed (Remote) Audio Amplifier, 50 watts. Please refer to the data sheet DF-60763 for more information. ECC-50DAE: Export version. Distributed (Remote) Audio Amplifier, 50 watts. (240 VAC, 50Hz). Please refer to the data sheet DF-60763 for more information. V Page 4 of 8— DF-60734:A2 • 8/22/13 ECC-125DA: Distributed (Remote) Audio Amplifier, 125 watts. Please refer to the data sheet DF-60763 for more information. ECC-125DAE: Export version. Distributed (Remote) Audio Amplifier, 125 watts. (240 VAC, 50Hz). Please refer to the data sheet DF-60763 for more information. ECC-CE4: Distributed Audio Speaker Circuit/Zone expander module. ECC-FFT: Fire Fighter Telephone System. Please refer to the data sheet DF-60765 for more information. FPJ-F: Remote Phone Jack. FHS-F: Fire Fighters Remote Handset. FHSC-RF: Fire Fighters Handset Cabinet Recessed. FHSC-SF: Fire Fighters Handset Cabinet Surface Mount MMF-301: Addressable Mini-Monitor Module. 1300: SLC Line Isolation Module. TR-CE: Optional Trim Ring. THUMBLTCH: Optional Thumb Latch. (Non UL-Listed). CHG-75: 25 to 75 ampere-hours (AH) External Battery Charger. CHG-120F: 25-120 ampere-hours (AH) External Battery Charger. ECC-MICROPHONE: Replacement Microphone only. BAT-1270: Battery 12 volt,7.0 AH (Two required). BAT-12120: Battery 12 volt,12.0 AH (Two required). BAT-12180: Battery 12 volt, 18.0 AH (Two required). Wiring Requirements See product manual, part number LS10001-000FL-E for detailed wiring requirements. Total System Capacity: (ECC.50/1 00(E) only) Total Built-in Audio Power: 50 Watts. Total Expandable Audio Power: 100 Watts. Total Built-in Speaker Circuits: 2. Total Expandable Speaker Circuits: 8. Audio Message Max Time Duration: 60 seconds. External Audio Input: 1. Total System Capacity: (Fully Loaded System) Total Distributed Audio Power: 1100 Watts. Total Speaker Circuits Per System: 24. Total Remote Consoles Supported: 8. Total Distributed Audio Amplifiers Supported: 8. Electrical Specifications PRIMARY (AC) POWER (TB 15) ECC-50/100: 120 VAC, 60 Hz, 3.5 amps (HOT, NEU). ECC-50/100E: 240 VAC, 50 Hz, 2.0 amps (HOT=HotLegl, NEU=HotLeg2). Wire size: minimum #14 AWG (2.00mm2) with 600 V insulation. SECONDARY POWER (BATTERY) CHARGING CIRCUIT (J7) Supports lead-acid batteries only. Float charge voltage at 27.3V Maximum charge current: 1.0 Amp Maximum battery charge capability: 2.8 Amps, 26AH (ECC cabinet holds max. 18AH battery). Minimum Battery size: 12 Amp Hour. AC LOSS RELAY CONTACT RATING (TB3) 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). FORM C - TROUBLE RELAY CONTACT RATING (TB2) 2.0 amps @ 30 VDC (resistive), 0.5 amp @ 30 VAC (resistive). MNS ACTIVE RELAY CONTACT RATING (TB1) 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). NOTIFICATION APPLIANCE CIRCUIT (NAC) OUTPUT RATING (TB19) One (1) Style Y (Class B) or Style Z (Class A) circuit. Power-limited circuitry, (Class 2) supervised. Nominal operating voltage: 24 VDC. Maximum signaling current for special application power: 2.OA. Maximum signaling current for regulated power: 200mA. Maximum wiring impedance: 12 Current limit: fuse-less, electronic, power-limited. End-Of-Line Resistor: 4.7 KQ 1/2 watt, (P/N 71252) required for Style V (Class B) operation. Refer to the Device Compatibility Document 15384 for listed compatible devices. NAC FOLLOWER OUTPUT REMOTE SYNC (TB 18) Connections for FACP NAC synchronization trigger signal. Output terminals: pass-through to other system compo- nents. Trigger input voltage: 9 to 32 VDC, 24 VDC rated. Input current draw in Alarm condition: 10 mA at rated volt- age. SPECIAL APPLICATION POWER (AUX. POWER) (TB 17) 500 mA @ 24 VDC. Used for powering addressable modules and associated End-of-Line power supervision relays. Power-limited circuitry. Refer to the Device Compatibility Docu- ment 15384 for a list of compatible devices. SPEAKER VOLUME CONTROL OVERRIDE (TB23) Style Y (Class B) or Style Z (Class A) circuit. Special application power. Power-limited circuitry, supervised. Nominal operating voltage: 24 VDC. Maximum signaling current: 0.25 amps. Current limit: fuse-less, electronic, power-limited. End-Of-Line Resistor: 4.7 KQ, ½ watt, (P/N 71252) required for Style V (Class B) operation. Speaker Circuits Primary Speaker Circuit (TB20) Secondary Speaker Circuit (TB21) (with optional amplifier only). - Circuit can be wired Style V (Class B) or Style Z (Class A). - Power-limited circuitry. - Normal Operating Voltage: 25 VRMS © 2 amps max and maximum Load Impedance of 12.59 (70.7 VRMS © 700 mA max. with maximum load Impedance of 10092 opera- DF-60734:A2 • 8/22/13 - Page 5 of 8 tion possible by plugging optional ECC-XRM-70V conver- sion transformer into J12 of the main control board). —Output Power: 50 watts (10 watts when background music is employed). - Frequency Range: 400Hz - 4,0001-1z. - Maximum total capacitance for each speaker circuit: 250 uF. - End-of-Line Resistor required for Style V circuit: 15 K, 1 watt (PIN: ELR-15K). Command Input Circuits (alarm polari. ties shown) CMD1 - TB4 Terminals 3(+) & 4(-) are input terminals and Ter- minals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices down stream. CMD2 - TBS Terminals 3(+) & 4(-) are input terminals and Ter- minals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices downstream. CMD3 - TB6 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD4 - T136 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. CMD5 - T137 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD6 - TB7 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. CMD7 - TB8 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD8 - TB8 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. Power-limited and supervised circuitry. Normal Operating Voltage Range: 10.5 VDC - 29 VDC; (Maximum Voltage: 29 VDC). NAC Reverse Polarity Current (requires End-of-Line Resis- tor from NAC): 1.6 mA maximum. Contact Closure Operation Current (requires 4.7KQ, 1/2 watt End-of-Line Resistor P/N 27072): 6.6 mA maximum. Maximum Wiring Impedance CMD1 - CMD8 (Contact Clo- sure Operation): 200. NOTE: When the system is programmed for Mass Notification, CMD land CMD2 will be programmed for Reverse Polarity only See manual P/N LS1000I-000FL-E for more details. MAXIMUM INPUT IMPEDANCE: CMD1 & CMD2 (Reverse Polarity Operation): 20K. CMD1 - CMD8 (Contact Closure Operation): 4.75K2 NIGHT RING INPUT - TB 16, TERMINALS 1 (+) & 2 (-) Contact closure input. Isolated, non-supervised. Operation current: 3.8 mA, maximum. Maximum wiring impedance: 30K. Minimum isolation withstand voltage: 1500 VRMS. EXTERNAL OPERATOR INTERFACE POWER OUTPUT (TB24) Non-resettable power for external operator interface com- ponents. Power-limited circuitry, non-supervised. Nominal operating voltage: 24 VDC. Maximum output current: 0.80 amps. Current limit: fuse-less, electronic, power-limited circuit. EXTERNAL DATA BUS (EIA -485) (TB12) Data connections for external operator interface components. Redundant transceiver circuitry for Class A operability. Power-limited circuitry, supervised. Maximum wiring impedance: 13.2I. FACP DATA BUS (EIA -485) (TB 13) Dedicated connection to FACP serial bus. Output terminals: pass-through to other system components. Isolated, supervised. Minimum isolation withstand voltage: 1500 VRMS. Maximum wiring impedance: 40I (ANN-BUS), 26 (ACS-BUS). External Audio Riser (TB22). Style V (Class B) or Style Z (Class A) audio connections to external operator interface components. Power-limited circuitry, supervised. Audio signal level: 3.85 V, maximum. Frequency range: 400 Hz - 4 KHz RMS. Frequency range (ECC-50/125DA): 800Hz - 2KHz RMS. ELECTRICAL SPECIFICATIONS DISPLAY BOARD EXTERNAL AUDIO INPUT (TB5) Input Impedance: 8.51<0 nominal @1 KHz. Input Voltage: 700 mV rms maximum. Input Current: 0.1 mA maximum © 700 mV. NOTE: Some laptops/personal computers only provide an audio output for headphones. It may be necessary to adjust the head- phone output level for proper recording of voice messages. ECC.CE6 Circuit Expander Module Specifications Power-limited circuitry. Up to six (6) circuits on the ECC-CE6 can be wired as Style V (Class B) or Style Z (Class A). Normal Operating Voltage for Speaker Circuits: 25 VRMS © 2.0 amps max. (Maximum Load Impedance of 12.5). 70.0 VRMS © 700 mA max. with maximum Load Imped- ance of 10092 operation possible for the primary circuit by plugging in an optional ECC-XRM-70V conversion trans- former into J12 of the main control board. The same opera- tion is possible for the optional 50W amplifier by selecting the ECC-50W-70V model. Speaker circuit wiring is supervised during standby, back- ground music, and alarm. Output Power: 50 watts total; Frequency Range: 4001-1z - 4,000Hz. Maximum total capacitance: 250 iiE (Note that the total capacitance for the speaker outputs must not exceed the maximum of 250 pF). End-of-Line Resistor required for Style V (Class B) speaker circuit: 15 K, 1 watt (P/N: ELR-15K)TB13 on the main control board: ACS/ANN (EIA-485) electrically isolated link to FACP provides programmed speaker control. Cabinet Specifications Backbox: 19.0(48.26 cm) high x 16.65°(42.29 cm) wide x 5.20(13.23 cm) deep. Door: 19.26" (48.92 cm) high x 16.82"(42.73 cm) wide x 0. 12"(0.30 cm) deep. Trim Ring (TR-CE): 22.00" (55.88 cm) high x 19.65" (49.91 cm) wide. Page 6 of 8— DF-60734:A2 • 8/22/13 Shipping Specifications Base Unit Weight: 27.85 lbs (12.63 kg). Temperature and Humidity ranges This system meets NFPA requirements for operation at 0492 C132-1202 F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90'F :t 3°F). However, the useful life of the systems standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 1527e C/60-802 F. Agency Listings and Approvals The listings and approvals below apply to the basic ECC-50/ 100(E) control panel. In some cases, certain modules may not be listed by certain approval agencies or listing may be in pro- cess. Consult factory for latest listing status. UL Listed S2424. Compliant with UFC 4-021-01. CSFM: 7300-0075:0227 FDNY: COA #6152 Standards and Codes The ECC-50/100(E) complies with the following UL Standards and with NFPA 72 Fire Alarm system requirements. UL 864. UL 2572. DF-60734:A2 • 8/22/13 - Page 7018 ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. OYCINFERING A MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 8 of 8— DF-60734:A2 • 8/22/13 DF-60760:A2 • C-230 ECC-RM Remote Microøhone (2) FIre•LITeALarms by Honeywell General Firelite's ECC-RM is an optional Remote Microphone that is compatible with the ECC-50/1 00(E) Emergency. Command Center for fire protection applications. It is part of a family of external remote consoles that allows for extending the opera- tor interface to remote locations within a building. It is housed in a cabinet with a keyed or an optional thumb lock to limit access to qualified personnel. The ECC-RM remote microphone allows for ALL CALL paging to be broadcast over the speaker circuits when depressing the microphone's push-to talk switch. The RM requires an external data bus connection, an external audio riser connection, and an external operator interface power connection (24 Volts DC) from the ECC-50/100 main console. TYPICAL APPLICATIONS Schools • Healthcare Facilities • Factories Theaters • Military facilities • Restaurants Auditoriums • Places of Worship • Office Buildings Dormitories Features External remote console that provides ALL CALL paging broadcasts over the speaker zones of the ECC-50/100(E) primary operating console. Modular design for maximum system flexibility and easy expansion. Supports both Class A (Style Z) and Class B (Style Y) wir- ing. A maximum of eight ECC-RM's can be connected to an ECC-50/100(E) primary operating console. Built-in microphone with push-to-talk feature that can be used for ALL CALL paging. Sturdy cabinet design with a keyed lock to prevent unautho- rized access. Optional thumb lock is available. Simple and straightforward user interface. Electrical Specifications PRIMARY POWER REQUIREMENTS: Voltage 24VDC non-resettable power from the ECC-50/ 100(E). External Operator Interface Power (Non-supervised). See ECC-50/100(E) Product Manual P/N LS10001-000FL-E for standby and alarm current requirements as well as battery calculations. Wiring Requirements See Product Installation Document PN: LS10029-000FL-E for detailed wiring requirements. Agency Listings and Approvals The listings and approvals below apply to the basic ECC-50/ 100(E) Fire emergency voice evacuation system. In some cases, certain modules may not be listed by certain approval agencies or listing may be in process. Consult factory for latest listing status. UL Listed S2424. CSFM: 7300-0075:0227 FDNY: COA #6152. FM Approved. Standards and Codes The ECC-RM complies with NFPA 101 Life Safety Code and with the following UL Standards and with NFPA 72 Fire Alarm system requirements. UL 864. Temperature and Humidity ranges This system meets NFPA requirements for operation at 0-49 C/32-120q F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90° F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27 C/60-802 F. Cabinet Specifications 8.3" (21.082 cm) high x 6.080(15.44 cm) wide x 4.337 (11.02 cm) deep (Door attached and closed). Shipping Specifications Weight: 4 lbs (1.81 kg). DF-60760:A2.9/1O/13—Page 1 of 4 -I- jti1 - ECC-FFT firefighter telephone nn '..4F ~hornsls~trobes E* ECC-50W-25/70V optional Internal options amplifier ECC-CE6 circuit expander _ C Circuit Speaker Circuits ~so El T1 I I1 L r ftJLI1[ EMERGENCY COMMAND CENTER ------------------- external battery distributed audio 11:322 charger - J7 14 remote consoles TB4 TB1 2 ECC-LOC ECC-RPU local operator console remote paging unit _ mmiol..IT ECC-SODA 50W ECC1 25DA 125W remote amplifier remote amplifier al CHG-1 20F charger CHG-75 charger ECC-50/100(E) Emergency Command Center (Possible Configurations) Page 2 of 4— DF-60760:A2 • 9/10/13 Control and Indicators PUSH BUTTON CONTROLS Microphone Push to talk switch LED STATUS INDICATORS (VISIBLE WITH DOOR CLOSED) System in Use (green) OK to Page (green) AC Power (green) Data Trouble (yellow) Audio Trouble (Yellow) Microphone Trouble (yellow) Product Line Information (Ordering Information) ECC-RM: Remote Microphone only. ECC-50/100: (Primary operating Console) 50 Watt, 25VRMS single speaker zone emergency voice evacuation system, Integral microphone, built in tone generator and 14 recordable messages. Please refer to the data sheet DF-60734 for more information. ECC-50/100E: Export version (Primary operating Console) 50 Watt, 25VRMS single speaker zone emergency voice evacua- tion system, Integral microphone, built in tone generator and 14 recordable messages. Please refer to the data sheet DF- 60734 for more information. ECC-CE6: Speaker Circuit/Zone Expander Module. ECC50W-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/100 power output to 100 watts or can also be used as a backup amplifier. ECC-50W-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total ECC-50/100 power output to 100 watts or can also be used as a backup amplifier. ECC-XRM-70V: 70V Transformer conversion module for 70V operation. ECC-LOC: Local Operator Console (Complete user interface), Please refer to the data sheet DF-60762 for more information. ECC-RPU: Remote Page Unit Hand held microphone, 14 message buttons. Please refer to the data sheet DF-60761 for more information. ECC-50DA: Distributed (Remote) Audio Amplifier, 50 watts. Please refer to the data sheet DF-60763 for more information. ECC-125DA: Distributed (Remote) Audio Amplifier, 125 watts. Please refer to the data sheet DF-60763 for more information. ECC-50DAE: Export version. Distributed (Remote) Audio Amplifier, 50 watts, 240 VAC, 50 Hz. Please refer to the data sheet DF-60763 for more information. ECC-125DAE: Export version. Distributed (Remote) Audio Amplifier, 125 watts, 240 VAC, 50 Hz. Please refer to the data sheet DF-60763 for more information. ECC-CE4: Distributed Audio Speaker Circuit/Zone expander module. ECC-FFT: Fire Fighter Telephone System. Please refer to the data sheet DF-60765 for more information. FPJ-F: Remote Phone Jack. FHS-F: Fire Fighters Remote Handset. FHSC-RF: Fire Fighters Handset Cabinet Recessed. FIISC-SF: Fire Fighters Handset Cabinet Surface Mount. MMF-301: Addressable Mini-Monitor Module. 1300: SLC Line Isolation Module. TR-CE: Optional Trim Ring. ECC-MICROPHONE: Replacement Microphone Only. CHG-75: 25 to 75 ampere-hours (AH) external battery charger. CHG-120F: 25-120 ampere-hours (AH) external battery charger. BAT-1270: Battery, 12volt, 7.OAH (Two required). BAT-11 2120: Battery, 1 2v01t, 12.OAH (Two required). BAT-12180: Battery, 1 2volt, 18.OAH (Two required). BB-26: Battery back box - Mounts up to 2, BAT-12260 Batteries. BB-55F: Battery Box -- Mounts up to 2, BAT-12260 or BAT- 12550s. MMF-300: Monitor module used to supervise dry contact input devices. THUMBLTCH: Optional Thumb Latch. (Non UL Listed). SYSTEM INUSE C) OR TO PAGE C) POWER CD DATA TROUBLE C) AUDIO TROUBLE CD MIC TROUBLE .-.- CD DF-60760:A2 .9/10/13 - Page 3 of 4 02013 by Fire-Lite Alarms. All rights reserved. Unauthorized use of this doc- ument is strictly prohibited. This document is not intended to be used for installation purposes. ____ Iso 9001 We try to keep our product information up-to-date and accurate. __ _____ We cannot cover all specific applications or anticipate all requirements. MSINIERING & MANDFACHRING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-60760:A2 • 9/10/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 6911-0075:0226 Page 1 of 1 CATEGORY: 6911 -- VOICE COMMUNICATION SYSTEMS CONTROL UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywell.com DESIGN: Models ECC-501100 and ECC-50/100E. These are 50-watt audio emergency voice evacuation panels expandable to 100-watt for fire applications, mass notification applications, or both. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: *ECC.LOC: Local Operator Console ECC-MCB; Main Control Board ECC-DKVCM; Display Board ECC-50W-25V; Amplifier Module 25 VRMS ECC-50W-70V; Amplifier Module 70 VRMS ECC-CE6; Speaker Circuit Expander Module ECC-XRM-70V; Transformer Module 70.7 VRMS RATING: Primary Operating: 120 V, 60 Hz, 3.5 A or 240 V, 50 Hz, 2 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as voice communication systems for use with separately listed compatible fire alarm control units to provide emergency voice evacuation signals. Refer to listee's Installation Instruction Manual for details. *12272016 dc TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 6912-0075:0228 Page 1 of 1 CATEGORY: 6912 --VOICE COMMUNICATION ACCESSORIES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneyweII.com DESIGN: Model ECC-FFT fire fighter telephone. Model ECC-RM remote microphone. Model ECC-RPU remote paging unit. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as voice communication accessories for use with listee's separately listed voice communication system. Refer to listee's Installation Instruction Manual for details. 09-04-13 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CELL-CAB-FL(C) CELL-CAB-FL(C) and CELL-MOD(C) Cellular Fire Alarm Communicators DF-60956:A (a Fireu-re®Atarms by Honeywell General The CELL-CAB-FL(C) and CELL-MOD(C) are cellular communica- tor options for Fire•lite Endurance Series addressable fire alarm control panels (FACPs). These GSM communicators are designed to interlace with the pre- installed IPOTS-COM dual technology (POTS and IP) communica- tor on the FACPs. They provide dual path cellular and IP reporting capability, while eliminating the need and cost of separate dialer capture modules and special programming. Battery backup from the control panel maximizes overall system efficiency. Small in size, easy to install, with a programmable supervision time of 1-60 minutes, these communicator models can be positioned remotely from the fire alarm control panel via 4-wire serial bus for optimum reception. The CELL-CAB-FL(C) and CELL-MOD(C) are UL 864 and NFPA 72 fire code compliant for sole, primary, or backup communications. They work with AlarmNet@ to provide a UL-listed connection to the central station. The CELL-CAB-FL(C) includes a GSM communicator within a metal cabinet enclosure with lock and key and includes an external antenna. The CELL-MOD(C) houses the GSM communicator in a plastic enclosure, (optional external antenna). Compatibility The CELL-CAB-FL(C) and CELL-MOD(C) are compatible with the following Endurance Series FACPs: ES-50X(C): 50 point addressable FACP ES-200X(C): 100 point addressable FACP Features Integrate directly with Endurance Series panels. Installation is easy as there is no need for special programming or a separate dialer capture module Battery backup provided by the fire alarm control panel to enhance efficiencies and cost savings Communicators provide dual path cellular and IP reporting capa- bility when combined with Endurance Series panels UL 864 and NFPA 72 code compliant for sole, primary, or backup communications Accounts can be easily managed through online management tools Remote mount of up to 6,000 feet to ensure best reception Includes Quality of Service (QOS) diagnostics via AlarmNet which conveys vital communicator information, including when messages are received, signal strength, and message path used Programmable supervision time from 1 - 60 minutes Provides full data reporting using Contact ID format DF-60956:A .1/23/2018—Page 1 of 2 SYSTEM SPECIFICATIONS PHYSICAL CELL-CAB-FL(C): 10.38"Wx 10.165H x 3.176°D CELL-MOD(C): 7.809"Wx 5.982H x 1.5"D Shipping Weight: 1 .31bs (CELL-MOD), 5.21bs (CELL-CAB-FL) Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10 to 93% relative humidity (non-condensing) ELECTRICAL Standby Current: 55mA Alarm Current: lOOmA RADIO TRANSCEIVER 3G Cellular Radio UMTS WCDMA FDD 850/1900MHz FCC part 15, 22, 24, and 68 compliant COMMUNICATION PROTOCOLS HSPA+ (4G) and HSPA (HSDPA & HSUPA) (3G) ORDERING INFORMATION CELL-CAB-FL: Cellular module housed in metal cabinet with lock and key. Includes external antenna CELL-CAB-FLC: Cellular module housed in metal cabinet with lock and key. Includes external antenna. For use in Canadian applica- tions with Canadian model FACPs. CELL-MOD: Cellular module housed in plastic enclosure. (External antenna sold separately) CELL-MODC: Cellular module housed in plastic enclosure. (Exter- nal antenna sold separately), For use in Canadian applications with Canadian model FACPs. GSM-ANT3DB: 3dB gain external/remote antenna 7626-50HC: 50 ft. antenna cable, low loss ES-50X(C): 50 point addressable FACP with pre-installed IPOTS- COM communicator ES-200X(C): 100 point addressable FACP with pie-installed IPOTS-COM communicator IPOTS-COM: Dual technology (POTS and IP) communicator (replacement board) for the Endurance Series panels APPROVALS UL: S3511 (CELL-MOD), S2424 (CELL-CAB-FL) ULC: S3511 (CELL-MODC), S2424 (CELL-CAB-FLC) FCC ID: CFS8DLPHS8-US AlarmNet® and Fire-LitelD Alarms are registered trademarks of Honeywell Inter- national Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so We try to keep our product information up-to-date and accurate. 9001 We cannot cover all specific applications or anticipate all requirements. ____________________ All specifications are subject to change without notice. :b dl I QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA www.flrelite.com Page 2 of 2— DF-60956:A • 1/23/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0504 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywell.com DESIGN: Model CELL-CAB-FL Cellular transmitter consist of a metal enclosure and cellular transmitter, "CCP-Lyric", for off-premise signaling. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings, and UL label. APPROVAL: Listed as a cellular transmitter for use with listee's Models ES-50X and ES-200X Fire Alarm Control Units (CSFM listing 7165-0075:0500). For indoor dry locations. Refer to manufacturer's Installation Manual for details. 03-13-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division df-52417:c • B-gO ANN-80 80-Character LCD (a FureLITeALarms Serial Annunciator by Honeywell General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. - •. - Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. -' . -. af ANN-80 is red; for white, order ANN-80-W. . ,-. 1101 The ANN-80 displays English-language text of system point - . . I? •' information including device type, zone, independent point ._ alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- .-i. ._-_' trol switches for remote control of critical system functions. (A L_. keyswitch prevents unauthorized operation of the control switches.) .7 Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KlT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-80s can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 490C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:211 MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. df-52417:c • 05/22/09 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and limited. TBI ANN-BUS Device MS-9050UD TB3 - 12345678 FACP Wiring to ANN-BUS Device ORDERING OPTIONS: ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB8OKIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. FireLite® Alarms is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BJlNEElllNC S MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-5241 7:c • 05/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of I CATEGORY: 7120--ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Model ANN-80 and *ANN80w remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division BG-1 2LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/o) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4 (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[131); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. Specifications Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 iA. Ambient Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4(10.16cm) square electrical outlet box, or will surface mount to the model SB-ia or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). DF-52013:B • E-1 00 (a Flre•LITeALarms by Honeywell Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600, 1 - 99 and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4 (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. DF-52013:B • 10/20/2008 - Page 1 of 2 Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S711 MEA: 67-02-E CSFM: 7150-0075:184 FM Approved I Detail of BREAKAWAY TAB* 9 9 14 15 1 I ADDRESS 0 [a:: 3 L1 032 Back of station without door Terminal Connections: 1 SLC (-); 2 SLC (+) E LED ROTARY DECIMAL SWITCHES I * Remove tab to select addresses above 99. Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Fire-Lite is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. -. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 93=1=1 We cannot cover all specific applications or anticipate all requirements. MCINEININS & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52013:13 • 10/20/2008 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075.-0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywell.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-12LW, BG-I2WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-I2SP, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-I2SL, UT-PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SD365(A) Series Addressable Photoelectric Detectors General The Fire-Lite SD365(A), SD365T(A), and SD365R(A) Series addressable plug-in photoelectric smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contempo- rary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the 5D365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The 5D365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the 5D365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: Please refer to the Fire-Life panel manuals for device capacity. ARCHITECTURE New modern profile for improved aesthetics. Unique single-source design to respond quickly and dependably to a broad range of fires. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Designed to meet UL 268 7th Edition. Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. Visible LED "blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. Low standby current. MECHANICALS Sealed against back pressure. Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0 (10.16 cm) octagonal box, or 4.0' (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS Remote LED output connection, RA100Z. DF-61010:A 8 FureLrre°Atarms by Honeywell 5D365 Installation 5D365(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class B) wiring. SD365R(A) mounts in a D355PL(A) or DNR(A) /DNRW duct detector housing. Operation Each SD365(A) Series detector uses one possible addresses on the Fire-lite Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an ES-50X or ES-200X addressable fire alarm control panel. The results of the sensitivity test can be printed off the for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 200 pA @ 24 VDC. Max current: 4.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0' (5.3 cm) high; base determines diameter. - B300-6: 6.1° (15.6 cm) diameter. - B501: 4' (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). DF-61010:A • 412118— Page 1 of 3 Operating temperature range: SD365(A): 0°C to 50°C (32°F to 1220F); SD365T(A): 0°C to 38°C (32°F to 100°F). SD365R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Relative humidity: 10%-93%, non-condensing. Listings Listings and approvals below apply to the SD365 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S1059 CSFM: 7272-0075-0502 FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: "IV" suffix indicates LiteSpeedo and CLIP device. NOTE: "A" suffix indicates Canadian version. SD365(A): White, Addressable photoelectric detector; B300-6 base included. LiteSpeed only. SD365(A)-IV: Ivory, Addressable photoelectric detector; B300-6 base included. SD365T(A): White, Same as SD365 but with thermal element; B300-6 base included. LiteSpeed only. SD3651(A)-IV: Ivory, Same as 5D365 but with thermal element; B300-6 base included. SD365R(A): White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. LiteSpeed only. SD365R(A)-IV: Ivory, Remote test capable addressable photoelec- tric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. ULJULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. B224R8-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224BlA-WH: White, isolator detector base, ULC listing. B224BlA-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: Color Kit (includes cover and trim ring), white, 10-pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. DF-61010:A • 4/4/18 -Page 2 of 3 FireLite® Alarms is a registered trademark of Honeywell International Inc. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IS09001 ___________________ All specifications are subject to change without notice. dl I .1 ENlNEERlNC & MANUFACTURING QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 3 of 3— DF-61010:A • 4/4/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0502 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett©Honeywell.com DESIGN: Models 5D365, 5D365R and 5D3651 analog addressable, photoelectric smoke detectors for open area and duct installations. Model SD365T has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models B2005 and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. XLF: 7272-0028:0503 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division to ~ 1 SYSYL'LTYII $ Siisoff Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNAUNG LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135.16530503 3057383 The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync-Circuit- Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones, Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. - H Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (1173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (1175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd lscd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 115cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.lKTemporal High 108 135 179 - 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVOSB6800 2.47 Ø62 2.50 1.37 L-Series Dimensions Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceilinci Horn Strobes PC2RL 2-Wire, Horn Strobe, Red 1 Ceilinci Strobes SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White TEM sys 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systernsensor.com 02017 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 u for c rrent product information, including be latest version of this data sheet. AVDS8680I .t23/t7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W Ceilinglrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features Plug-in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings on ceiling units: 15, 30, 75, 95,115,150, and 177 Automatic selection of 12- or 24-volt operation at 15 and 30 candela Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4, 1/2, 1 and 2 watts) Speakers offer high fidelity and high volume sound output 520 Hz capable with compatible FACP Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products Tamper-resistant construction Updated modern aesthetics Agency Listings SIGNALING APPROVED 0 LISTED 34048 FM approved except 7320-16500505 for ALERT models 3057493 System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SF speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. L-Series makes installation easy Attach a universal mounting plate to a 4 x 4 x 21i8 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the SynclCircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor [-Series model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 x 411/16 x 21,8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Back Box 6.9 in, 176 mm - 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm - ° Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC or regulated 24 VDC/FWR 1,2 Operating Voltage Range (includes fire 8t0 17.5 V(12 V nominal) or 161033 V (24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz3 Power ¼,½,1,2watts Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 and 30 cd. 520Hz capable with compatible FACP. UL Current Draw Data -- 8t0 17.5 Volts 16 to 33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 :J Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 if) 1/4W 79 79 1/2W 82 82 1W 85 85 2W 88 88 II Li •1 • Setting UL Reverberant (dBA @10 if) UL Anechoic (dBA @10 if) 1/4W 77 77 1/2W 80 80 1W 83 83 2W 86 86 L-Series Dimensions 6.8Odia 1.00 Ceiling Speaker 680 die Ceiling Speaker Strobe Surface Mounting Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box L-Series Ordering Information k - '•'--:-," ,,-'--'-.- flhtTT1u io . White Red Description SPCWL SPCRL Speaker only SPSCWL SPsçRL Speaker Strobe SPSCWL-P - Plain, Speaker Strobe SPSCWL-SP - Fuego, Speaker Strobe SPSCWL-CLR-ALERT - Alert, Speaker Strobe, Clear Lens White Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceilinct Trim Rin ,5'yF5ypr 3825 Ohio Avenue • St. Charles, IL 60174 @2017 System Sensor. Phone 800-SENSOR2 • Fax 630-377-6495 Product specifications subject to change without notice. Visit systemsenSor.com for current product information, including the latest version of this data Sheet www.systemsensor.com AVDS86601 • 03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-1653:0505 Page 1 of 2 CATEGORY: 7320-- SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: System Sensor Indoor Models: SPRL and SPWL Wall Speakers; SPCRL and SPCWL Ceiling Speakers; SPSRL, SPSWL, SPSRL-P, SPSRL-SP, SPSWL-P, SPSWL-ALERT and SPSWL-CLR-ALERT Wall Speaker Stobes; SPSCRL, SPSCWL, SPSCWL-P, SPSCWL-SP and SPSCWL-CLR-ALERT Ceiling Speaker Strobes. Wall Bezel Parts: BZSPR-P, BZSPR-AL, BZSPR-EV, BZSPR-AG, BZSPR-PG, BZSPR-F and BZSPR-SP, BZSPW-P, BZSPW-AL, BZSPW-EV, BZSPW-AG, BZSPW-PG, BZSPW-F and BZSPW-SP, Ceiling Bezel Parts: BZSPRC-P, BZSPRC-AL, BZSPRC-EV, BZSPRC-AG, BZSPRC-PG, BZSPRC-F and BZSPRC-SP, BZSPWC-P, BZSPWC-AL, BZSPWC-EV, BZSPWC-AG, BZSPWC-PG, BZSPWC-F and BZSPWC-SP, WallTrim Rings for Speaker Strobes: TR2 and TR2W Ceilinglrim Rings for Speaker Strobes: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBSPRL and SBBSPWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-27-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7320-1653:0505 Page 2 of 2 RATING: 25 or 70.7 VAC, 1/4, 1/2, 1, 2 Watt outputs. Regulated 12 VDC and 24 VDC/FWR is for 2-wire strobe portion. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as speakers and speaker-strobes when used with separately listed compatible fire alarm control units. Suitable for indoor use, dry and damp environments. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. U 02-27-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division df-60379:A1 • E-400 CRF.300(A) RIav Mndul (a FlreLITe®Atarms -" -----..- -. .- by Honeywell The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTm is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED 'blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01-159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Ste Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. IC 7 . CO I.... . CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125' (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (UR=5m5) Coded 30 VDC 0.5 A Inductive (UR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA:72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. LiteSpeedTM is a trademark and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. iso 900i This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 9313=1=1 We cannot cover all specific applications or anticipate all requirements. M0111111110 S MSNHFSCThRINC QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-60379:A1 • 08/04/09 df-52121:b • E-325 MMF-300(A) Series, M DF-300(A) (a FIreLlTeALarms Addressable Monitor Modules IJy V"VYVV vII General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75' (6.985 cm) W x 0.5' (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it monitors. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF.300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, water-flow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class MMF-300 (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300 OPERATION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Maximum operating current: 375 hA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF.301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. df-52121:b.11/13/08— Pagel of4 141 0 1 ADDRESS I 01 LOOP 10 __ 9 76 8 76 TENS ONES I-.- o LU -.4 0 CZ The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules in exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 hA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 491C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3° (3.302 cm) high x 2.75 (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. MMF.302 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. MMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 OPERATION Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing). EOL resistance: 3.91K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 491C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125 (5.398 cm) deep box. MDF.300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MOF-300 provides two Class B (Style B) IDC circuits ONLY. Class A (Style 0) IDC circuits are NOT supported in any application. MDF-300 SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Maximum operating current: 750 i.tA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32° to 120°F (0° to 490C). Humidity range: 10% to 93% (non-condensing). Page 2 of 4— df-52121 :b • 11/13/08 Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S3705 ("A" suffix models) FM Approved CSFM: 7300-0075-185 MEA: 72-01-E Product Line Information NOTE: "A" suffix indicates ULC Listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. dt-52121:b• 11/13/08 —Page 3 of 4 FireLite® and LiteSpeed® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCHUMINS &MRNUHICTURINt QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 —df-52121:b • 11/13/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 110104 91 M 1 2 LI I N MWIS £ is the 11 BW-DocBox BW-DocBox 15"W x 13" H x 4" D includes: THREE labels: "Fire Alarm Documents" "As Built Permits" "Test and Maintenance Documents" An adjustable bungee allows you to fit various sizes of binders, documents, smoke-cans, etc. A door bracket holds two CDs, three sets of keys and more documents A cam lock with two keys Don't see the box you want? Call us or visit our website! Customization and/or silk-screening of logos is available for quantities of 25 or more. (requires lead time) BW-DocBox2 11"W x 15"H x 4"D Smaller and more basic model without the door bracket for CDs and key sets. However, it does have the three labels, adjustable bungee and a lock with two keys. BW-DocBox2 vu :r I C, ___ L L Mademthe ODUCTS, INC. 1-800-473-0213 I www.mierproducts.com -- ------- FPC2OI9-0160 6965 EL CAMINO REAL #202 AUDEO II CHARTER SCHOOL - FIRE ALARM & VOICE EVAC 2150507500 7/1512019