HomeMy WebLinkAbout1525 FARADAY AVE; 150; CBC2022-0175; PermitBuilding Permit Finaled
Commercial Permit
Print Date: 09/12/2022
Job Address: 1525 FARADAY AVE, # 150, CARLSBAD, CA 92008-7373
Permit Type: BLDG-Commercial Work Class: Tenant Improvement
Parcel#: 2121302700 Track#:
Valuation: $102,558.00 Lot #:
Occupancy Group: B Project #:
#of Dwelling Units: Plan#:
Bedrooms:
Bathrooms:
Construction Type:V-N
Orig. Plan Check#:
Occupant Load: Plan Check #:
Code Edition: 2019
Sprinkled: Yes
Project Title:
Description: HUB: COM-Tl (7,308 SF) REMODEL EXISTING OFFICES SU ITE (150)
Applicant: Property Owner:
PAUL NUGENT
4631 VIEWRIDGE AVE, # A
SAN DIEGO, CA 92123
EMERALD LAKE CORPORATE CENTRE LP
1525 FARADAY AVE, # 100
CARLSBAD, CA 92008
FEE
BUILDING PLAN CHECK
BUILDING PLAN REVIEW -MINOR PROJECTS (LOE)
BUILDING PLAN REVIEW -MINOR PROJ ECTS (PLN)
CERTIFICATE OF OCCUPANCY
COMM/IND Tl -NON-STRUCTURAL
SB1473 -GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION -COMMERCIAL (SMIP)
Total Fees: $3,135.09 Total Payments To Date: $3,135.09
\Ccityof
Carlsbad
Permit No: CBC2022-0175
Status: Closed -Fina led
Applied: 05/27/2022
Issued: 07/08/2022
Finaled Close Out: 08/18/2022
Final Inspection: 08/18/2022
INSPECTOR: Kersch, Tim
Balance Due:
AMOUNT
$1,100.81
$194.00
$98.00
$15.00
$1,693.56
$5.00
$28.72
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedicat ions, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as t o which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I w ww.carlsbadca.gov
{_ City of
Carlstiad
COMMERCIAL
BUILDING PERMIT
APPLICATION
8-2
Plan Check ~c:x6? ~ 0 l'rY
Est. Value dJ>f33q,gj.s -68
PC Deposit
Job Address 1525 Faraday Ave
Tenant Name#: HUB International
Sulte:150/160 APN:212-130-27-00
Lot#: 102 Year Built: _2...,0...,0.._1 _____ _
Year Built: 2001 Occupancy:_B __ Construction Type:~ Fire sprlnklers()YESONO A/C:()YES(O)NO
X X BRIEF DESCRIPTION OF WORK:
D Addition/New: ___________ New SF and Use, _________ New SF and Use
______ SF Deck, SF Patio Cover, SF Other (Specify) ___ _
l;)Tenant Improvement: 7,308 SF, Existing Use: -'O~ffi=1=ce~---Proposed Use: o _ _..ffi .... c~e---__ _
____ SF, Existing Use: Proposed Use: _____ _
O other: ----------------------------------
PRIMARY APPLICANT
Name:Emerald Lake Corporate Centre, LP
Address: 1525 Faraday Ave., Suite 100
City:Carlsbad State: CA Zip: 92008
Phone: (760) 607-4283
Ema11dbrusseau@newportnational.biz
PROPERTY OWNER
Name: Emerald Lake Corporate Centre, LP
Address:1525 Faraday Ave., Suite 100
Clty:Carlsbad State: CA Zip:92008
Phone:(760) 607-4283
Email: jbrusseau@newportnational.biz
DESIGN PROFESSIONAL CONTRACTOR OF RECORD
Name: Design Corp -Paul Nugent Business Name: JACOR CONSTRUCTION, INC.
Address:4631 Viewridge Ave Address: 10735 PROSPECT AVE
City: San Diego State: CA Zip:92123 City: SANTEE state: CA Zlp:._9_20_1_1 ___ _
Phone:(619) 962-7800 Phone: 619-562-8183
Email: pnugent@designcorpsd.com Email: ashley@jacor-sd.com, rick@jacor-sd.com, jim@jacor-sd.com
Architect State License: _.C,r;al.,.D.,..#..,,3..,8..,S~P------------CSLB License#: 489412 Class:._B _____ _
Carlsbad Business License# (Required): BLOS1235613
APPLICANT CERT/FICA TION: I certify that I have read the application and state that the above information ts correct and that the
information on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building
construction.
NAME {PRINT): _A_s_hl_e_y _H_u_ss ____ _ SIGN: A4$: t(U44-
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719
07/07/2022
DATE:------
Email: Building@carlsbadca.gov
REV. 04/22
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON
SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO
PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
lherebyaffirmunderpenaltyofperjurythatlamlicensedunderprovisionsofChapter9(commencingwithSection70<XJ)ofDivision3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penal tyof perjury one of the
following declarations (CHOOSE ONE):
01 have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. Policy No .. ________________________________________ _
-OR-
[31 have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued.
My workers' compensation Insurance carrier and policy number are: Insurance Company Name: Snapp & Associates Insurance Services, LLC
Polley No. A0161374001 Expiration Date: _4_11_12_02_a _____________ _
-OR-
O Certificate of Exemption: I certify that in the performance of the work for which this permit Is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code,
interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is Issued (Sec. 3097 (i) Civil Code).
Lender's Name: ______________________ lender'sAddress: _____________________ _
CONTRACTOR CERTIFICATION; The applkant cert/fits thota/1 documents ond plans clearly and aca,rotely show all existing and propos~ buildings, structures, access roads, and
utillties/utility easements. All proposed modifications and/or addition, art clearly labeled on the site pion. Any potent/ally existing detail within these plans lncanslstent with the site plan are not
approved for construction and may be required to be altered or removed. Tlle city's approval of the application is based on the premise thot the submitted dowments and plans show the carrect
dimensions of; the property, buildings, structures and their setbacks fram property lines and from one another; access roads/easements, and utilities. The exi,tlng and proposed use of eoch building
as stated is true and corred; all easements ond other encumbronc:t!s to development have been accurately .shown and labeled as well as all on~site grading/site preparation. All improvements
alsting on tM pro~rty were compltted in accordance with all regulations in existence at the time of their construction, unless otherwi~ noted.
NAME (PRINT): Ashley Huss .....:.!~~~:..!.!::=::...._ __ DATE: 7 /7 /22
Note: If the person signing above Is an authorued agent for the contractor provide a letter of a ---------------------
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby aff irm that tam exempt from Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure Is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or Improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
--OR-
01, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's license Law).
-OR-01 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
D FORM 11-61 -OW.-Bulder Ad>w,w.....,,,..,t and Verification Form" is required for any permit issued to a l)(operty owner.
Dv my s;gnatwe below I adcnowledge that. except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this pennit_ I cannot legally seU a strocture that I have built as an owner-builder if it has not been constructed in its entirety by licensed
axrtractors.1 understand that a copy of the opp/I cable law, Section 7044 of the Business and Professions Code, is available upon request when thisappllcatlon is
submitted or at the following Web site: http:Ilwww.leglnfo.ca.gavtcalaw. html.
OWNER CERT/FICA T/ON: The applicant certifies that all documents ond plans clearly and accurately show al/existing and proposed buildings, structures, access roads, and utl/ltles/utllity
ea~ments. All proposed modifications and/or additions ore dearly labeled on the site pion. Any potentially existing detail within these plans inconsistent with the site plan ore not approved for
construction and may be required to be altered or removed. The city's approval of the application Is based on the premise that the submitted documents and plans show the carrtct dimensions of;
the praperty, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. Tht existing ond propos,d use af each building as stated Is true
and correct; all easements and other tmcumbrances to <kvelopment have ~en accurately shown and labeled as well as all on•site grading/site preparation. All improvements existing on the property
were completed in accordance with all regulations In existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGN: __________ DATE: ______ _
Note: If the person signing above Is an authorized agent for the property owner Include form B-62 signed by property owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
2 REV. 04/22
Building Permit Inspection History Finaled
(city of
Carlsbad
PERMIT INSPECTION HISTORY for (CBC2022-0175)
Permit Type: BLDG-Commerc ial Application Date: 05/27/2022 Owner: EMERALD LAKE CORPORATE CENT RE
LP
Work Class: Tenant Improvement Issue Date: 07/08/2022 Subdivision: CARLSBAD TCT#85-24 UNIT#0S
Status: Closed -Finaled Expiration Date: 01/23/2023 Address: 1525 FARADAY AVE, # 150
IVR Number: 40920 CARLSBAD, CA 92008-7373
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
07/14/2022 07/14/2022 BLDG-84 Rough 186853-2022 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
07/19/2022 07/19/2022 BLDG-17 Interior 187152-2022 Passed Tim Kersch Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/25/2022 07/25/2022 BLDG-44 187554-2022 Passed Tim Kersch Complete
Rough/Ducts/Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/18/2022 08/18/2022 BLDG-Final Inspection 189461-2022 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Monday, September 12, 2022 Page 1 of 1
OFFICE USE ONLY SAN DIEGO REGIONAL
HAZARDOUS MATERIALS
QUESTIONNAIRE
RECORDID# _________________ I
PLANCHECK# _________________ I
Business Name
Hub International
Business Contact
Danna Baker
State
BP DATE
Telephone#
(951) 505-5010
Zip Code APN# Project Address (Include suite)
1525 Faraday Ave., Suite 150
City
Carlsbad CA 92008 212-130-27-00
Malling Address (Include suite)
1525 Faraday Ave., Suite 150
Project Contact
Paul Nugent
City
Carlsbad
State
CA
Zip Code
92008
Applicant E-mail Telephone#
pnugent@designcorpsd.com 619-962-7800
Plan FIie#
The following questions represent the facility's activities, NOT the specific project description.
p R
I
applicant must contact the Ire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: Facility's Square Footage (including proposed project):
13. Corrosives 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives
2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These.
4. Flammable Solids 8. Unstable Reactlves 12. Radioactives
PART II: SAN DIE
questions s yes, a Call (858) 505-6700 prior to the issuance of a bull ing permit.
ls DIVIS 00, 55
Expected Date of Occupancy: FEES ARE REQUIRED Project Completion Date:
(for new construction or remodeling projects)
Is your business listed on the reverse side of this fonn? (check all that apply). 1.
2.
3.
4.
5.
6.
7.
8.
YES NO
□ [El □ [El Will your business dispose of Hazardous Substances or Medical Waste In any amount?
Will your business store or handle Hazardous Substances In quantities greater than or equal to 55 gallons, 500
pounds and/or 200 cubic feet? □ [El
□ □ □ □ □
[E) WIii your business store or handle carcinogens/reproductive toxins In any quantity?
@ Will your business use an existing or install an underground storage tank?
[El WIii your business store or handle Regulated Substances (CalARP)?
@ ~ill your business use or install a Hazardous Waste Tank System (lltle 22, Article 10)?
[E) WIii your business store petroleum In tanks or containers at your facility with a total facility storage capacity equal to
or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act).
· If the answer to any of the
n Diego, CA 92123.
D CalARP Exempt
Date lnltials
0 CalARP Required
I
Date Initials
0 CalARP Complete
I
Date Initials
P The following questions are Intended to Identify the majority of air pollution
I ed by these questions. Some residential projects may be exempt from APCD
requirements. If yes Is answered or either questions 1, 2 or 5 or for more comprehensive requirements, please contact APCD at apcdcomp@sdcounty.ca.qov;
(858) 586-2650; or 10124 Old Grove Road, San Diego, CA 92131.
YES NO
1. [E) O Will the project disturb 100 square feet or more of existing building materials?
2. D [El Will any load supporting structural members be removed?
3. @ D (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by an individual that has passed an EPA-approved
bullding Inspector courae?
4. D [E) (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Based on the survey results, will the project disturb any asbestos containing material? If yes, a
notification may be required at least 1 o working days prior to commencing asbestos removal. Additionally, a notification may be required prior to
the removal of a load supporting structural member(s) regardless of the presence of asbestos.
6. 0 [El WIii the project or associated construction equipment emit air contaminants? See the reverse side of this form for typical equipment requiring an
APCD permit. If yes, contact APCD prior to the Issuance of a building permit.
6. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1.000 feet of a school
bounda
Briefly describe business activities:
Insurance brokerage that p-ovldes employee--• buolneoe, & personal in8'ftnce producb and
I declare under penalty of perjury that to the best of my knowledge a
Paul Nugent
Name of OWner or Authorized A ent
ed project:
nt re edel of existing office space
FO FIRE DEPARTMENT OCCUPANCY CLASSIFICATION· _______________________________ _
BY; DATE: I I
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMO" COUNTY-HMO APCD COUN'TY-HMO APCO
• A stamp In this box only exempts businesses from completing or updating a Hazardous Materials Business Pian. Other permitting requirements may still apply
HM-9171 (9/18) County of San Diego • DEH • Hazardous Materials Division
Development Services
C Cicyof
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50 \ 1~0 cc€
Building Division
1635 Faraday Avenue
442-339-2719
www.carlsbadca.gov
l This checklist is intended to help building permit applicants identify whia.!)\Olim~te Action Plan (CAP) ordinance requirements
apply to their project. This completed checklist (B-50) and summary\(ID~5Y must be included with the building permit
application. The Carlsbad Municipal Code (CMC) can be referenced during completion of this document by clicking on
the provided links to each municipal code section.
NOTE: The following type of permits are not required to fill out this form
❖ Patio 1 ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate
certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy
compliance, IECC/HERS Compliance Specialist, ICC G8 Energy Code Specialist, RESNET HERS rater certified, certified
ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen
Inspector/Plans Examiner, or Green Building Residential Plan Examiner.
If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
check NIA and provide an explanation or code section describing the exception.
Details on CAP ordinance requirements are available at each section by clicking on the municipal code link provided. The
project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and
Green Code sections.
Project Name/Building
Permit No.: Emerald Lake Corporate Centre / Hub lnt'I Suite 150 BP No.:
Property Address/APN: 212_130_27_00 .=.==...,;;=-"-....=..;.~'------------------------------
Applicant Name/Co.: Paul Nugent/ Designcorp
Applicant Address: 4631 Viewridge Avenue
Contact Phone: 619-962-7800 Contact Email: pnugent@designcorpsd.com
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
B-50
Contact Phone: 619-962-7800
Contact Email:
Page 1 of 7 Revised 04/21
Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For
alterations and additions to existing buildings, attach a Permit Valuation breakdown on a separate sheet.
Building Permit Valuation (BPV) $ breakdown 100,000.00
I Conetructlon Type I Complete Sectlon(9) I Notti:
A high-rise residential building is 4 or more stories, including a
□Reeldentlal
D New construction
D Additions and alterations:
D BPV < $60,000
D BPV 2: $60,000
D Electrical service panel upgrade only
D BPV 2: $200,000
0 NOheeidentlal
D New construction
D Alterations:
l!!!!I BPV 2: $200,000 or additions 2: 1,000
square feet
D BPV 2: $1,000,000
D 2: 2,000 sq. ft. new roof addition
Checklist Item
Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor
area is residential use
2A*, 3A*, 1B, 2B, *Includes detached, newly constructed ADU 4A*, 3B,4A
N/A N/A All residential additions and alterations
1A, 4A 4A 1-2 family dwellings and townhouses with attached garages
only.
*Multi-family dwellings only where interior finishes are removed
1A, 4A* 1 B, 4A* and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
1 B, 2B, 3B, 4B and 5
1B, 5
1B, 2B, 5 Building alterations of 2: 75% existing gross floor area
2B,5 1B also applies if BPV 2: $200,000
Check the appropriate boxes, explain all not applcable and exception items, and provide suppoiting calculations and documentalion as necessay.
1. Energy Efficiency
Please refer to Carlsbad Municipal Code (CMC) 18.21. 155 and 18.30.190,and the California Green Building Standards Code (CALGreen) for more
information. Appropriate details and notes must be placed on the plans according to selections chosen in the design.
A D Residentialadditionoralteration~$60,000buildingpennltvaluation. D N/A _________ _
Detailsofselectionchosenbelowmustbe placed on the plansreferencingCMC □ Exception: Home energy score 2: 7
18.30.190. (attach certification)
Year Built Single-family Requirements Multi-family Requirements
D Before 1978 Select one option:
□ Ductsealing □ Attic insulation □Cool roof □ Attic insulation
□ 1978 and later Select one option:
□ Lighting package □ Water heating Package
□ Between1978and1991 Select one option:
D Ductsealing D Attic insulation □Cool roof
D 1992 andlater
Select one option:
□ Lighting package D Water heating package
Updated 4/16/2021 3
8. Nonresidentiar new construction or alterations ~ $200,000 building pennit valuation,
or additions;? 1,000 square feet. See CMC 18.21.155and CALGreen Appendix AS □ NIA
A5.203.1.1Chooseone:O.1 Outdoorlighting D .2 Restaurantservicewaterheating{CEC 140.5)
□ .3Warehousedocksealdoors. ~DaylightdesignPAFs D .5Exhaustairheatrecovery □ N/A
AS.203.1.2.1 Choose one: D .95 Energy budget {Projects with indoor lighting OR mechanical)
'f5 .90 Energy budget {Projects with indoorlightingANDmechanical) □ N/A
AS.211.1 ... D On-site renewable energy:
~ N/A
AS.211.3 .. D Green power: {If offered by local utility provider, 50% minimum renewable sources)
NIA
AS.212.1 D Elevators and escalators: (Project with more than oneelevatorortwoescalators)
N/A
AS.213.1 Steelframing: {Provide details on plans for options 1-4 chosen)
□ N/A
• Includes hotels/motels and high-rise residential buildings
---------
•• For alterations~ $1,000,000BPVandaffecting > 75% existing gross floor area, ORalterationsthatadd 2,000squarefeetof new roof addition: comply
with CMC 18.30.130 {section 2B below) instead.
i 2. Photovoltaic Systems
A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California
Energy Code section 150.1(c)14 for requirements. If project includes installation of an electric heat pump water heater pursuant to
CAP section 3B below (low-rise residential Water Heating), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional CFA #d.u. Calculated kWdc*
sheets if necessary)
Total System Size:
kWdc = {CFAx.572) / 1,000 + (1 .15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
kWdc
Exception
□
□
□
□
B. 0 Nonresidential new construction or alterations ~$1,000,000 BPV AND affecting ~75% existing floor area, OR addition that increases
roof area by c?2,000 square feet Please refer to CMC 18.30.130 when completing this section. *Note: This section also applies to
high-rise residential and hoteUmotel buildings.
Choose one of the following methods:
D Gross Floor Area (GFA)Method
GFA:
□ If< 1 O,0O0s.f. Enter: 5 kWdc
Min. System Size:
□ If~ 10,000s.f. calculate: 15 kWdcx (GFA/10,000) ••
kWdc
**Round building size factor to nearest tenth, and round system size to nearest whole number.
Updated 4/16/2021 4
□ Time-Dependent Valuation Method . ·
:f.
AnnualTDVEnergy use:*** ______ .x .80= Min. system size: ______ kWdc
***Attach calculation document1=1tion using modeling software approved by the California Energy Commission.
3. Water Heating
A D Residential and hotel/motel new construction. Refer to CMC 18.30.170 when completing this section.
Provide complete details on the plans.
□ For systems serving individual dwelling units choose one system:
□ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only)
□ Heat pump water heater AND PV system .3 kWdc larger than required in CMC 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential)
□ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
□ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
D Exception:
D For systems serving multiple dwelling units, install a central water-heating system with ALL of thefollowing:
D Gas or propane water heating system
D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low-
rise residential)
D Solar water heating system that is either:
D .20 solar savings fraction
D .15 solar savings fraction, plus drain water heat recovery
D Exception:
B. D Nonresidential new construction. Refer to CMC 18.30.150 when completing this section. Provide
complete details on the plans.
D Water heating system derives at least 40% of its energy from one of the following (attach documentation):
D Solar-thermal D Photovoltaics D Recovered energy
D Water heating system is (choose one):
D Heat pump water heater
D Electric resistance water heater(s)
□Solar water heating system with .40 solar savings fraction
D Exception:
It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to
demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a
performance approach to comply with energy-related measures will need to attach to this checklist separate calculations
and documentation as specified by the ordinances.
Updated 4/16/21 5
' I
4. Electric Vehicle Charging
A. D Residential New construction and major alterations*
Please refer to CMC 18.21.1 40 when completing this section.
D One and two-family residential dwelling or townhouse with attached garage:
D One EVSE Ready parking space required D Exception :
D Multi family residential· -D Exception ·
Total Parking Spaces EVSE Spaces
Proposed EVSE (10% of total) I Installed (50% of EVSE)l Other "Ready" I Other "Capable"
I I l
Calculations: TotalEVSEspaces= .10xTotalparking spaces proposed{roundeduptonearestwholenumber) EVSE lnstaled = Total EVSE
Spaces x .50 {rounded up to nearest v.tiole number) EVSE other may be "Ready" or "Capable"
*Major alterations are: ( 1) forone and two-family dwellings and townhouses with attached garages, alterations have a building permit
valuation::!:$60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached
garages), alterations have a building permit valuation::!: $200,000, interiorfinishesare removed and significant site work and upgrades to
structural and mechanical, electrical, and/or plumbing systems are proposed.
* ADU exceptions for EV Ready space {no EV ready space required when):
(1) The accessory dwelling unit is located within one-half mile of public transit.
(2) The accessory dwelling unit is located within an architecturally and historically significant historic district.
(3) The accessory dwelling unit is part of the proposed or existing primary residence or an accessory structure.
(4) When on-street parking permits are required but not offered to the occupant of the accessory dwelling unit.
(5) When there is a car share vehicle located within one block of the accessory dwelling unit.
B. 0 Nonresidential new construction (includes hotels/motels) D Exception : ____________ _
Please refer to CMC 18.21.150 when completing this section
Total Parking Spaces
Proposed EVSE (10% of total) I Installed (50% of EVSE) I Other "Ready" I Other "Capable"
I I I
Calculation· Refer to the table below·
Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces
□ 0-9 1 1
□ 10-25 2 1
□ 26-50 4 2
□ 51-75 6 3
□ 76-100 9 5
□ 101-150 12 6
□ 151-200 17 9
□ 201 andover 1 O percent of total 50 percent of Required EV Spaces
Calculations: Total EVSE spaces= .10 x Total parking spaces proposed {rounded up to nearest whole number) EVSE Installed = Total EVSE
Spaces x .50 {rounded up to nearest v.tiole number) EVSE other may be "Ready" or "Capable"
Updated 4/16/2021 6
• • I I
5. Transportation Demand Management (TOM): Nonresidential ONLY
An approved Transportation Demand Management (TDM) Plan is required for all nonresidential projects that meet a IIYeshold of employee-generated ADT.
CitystaffwillusethetablebelowbasedonyoursubmittedplanstodeterminewhetherornoryourpermitrequiresaTDMplan.lfTDMisapplicabletoyour
permit, sta_ffwill contact the applicant to develop a site-specific TDM plan based on the permit details.
Acknowledgment:
Person other than App
Employee ADT Estimation for Various Commercial Uses
Office (all)2 20
Restaurant 11
Retail3 8
Industrial 4
Manufacturing 4
Warehousing 4
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 10'hEdition
13
11
4.5
3.5
3
1
2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
sample ca1cu1atjons:
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf= 8 ADT
2. 9,334 sf -1,000 sf= 8,334 sf
3. (8,334 sf/ 1,000 x 4.5) + 8 = 46 Employee ADT
N (p . led) Jeff Brusseau ame nn :. __________________ _ Ph N be 760-607-42f2 one um r. ____ _
E .111..id jbrusseau@newportnational.biz ma1 ~ ress: __________________ _
Updated 4/16/2021 7