Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2548 CAMPBELL PL; ; FPC2020-0082; Permit
Cr'city of Carlsbad Print Date: 10/06/2020 Permit No: FPC2020-0082 Job Address: 2548 CAMPBELL PL, CARLSBAD, CA 92009-1700 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fixed Extinguishing Syste Parcel U: 2132611700 Track U: Applied: 05/06/2020 Valuation: $1,813,890.00 Lot U: Issued: 05/18/2020 Occupancy Group: Project U: Finaled Close Out: 10/06/2020 #f Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: VIASAT N4 -CLEAN AGENT (FM-200) TWO FIRE SYSTEMS MDF-1.076 & IDF-2.088 Applicant: FPContractor: SCHMIDT FIRE PROTECTION INC SCHMIDT FIRE PROTECTION CO INC-DO NOT GORDON SWOPE USE 4760 MURPHY CANYON RD 4760 MURPHY CANYON RD SAN DIEGO, CA 92123-4321 SAN DIEGO, CA 92123 (619) 871-9753 (858) 279-6122 FEE AMOUNT FIRE Pre-Action System with Alarm $553.00 FIRE Pre-Action System with Alarm $553.00 Total Fees: $1,106.00 Total Payments To Date: $1,106.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FFC-2-ow - O o 7- A UL 'hmidt Fir! Protection Co. Inc. 11 — 4760 MURPHY CANYON RD • SAN DIEGO, CA 92123' (858) 279-6122 • FAX (858) 279-3583 VIASAT N4T.l. 2548 Campbell Place San Diego, CA 92009 FM-200 Fire Suppression System MDF RM-1.076 & IN RM-2.088 SUBMITTAL PACKAGE Design by: Gordon E. Swope SET (NICET Level-IV #078621) (619) 871-9753 gordoncschmidtfireprotection.com.com Date May 4, 2020 -F IRE --SYSTEMS" Janus Fire Systems FM-200 Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.11 .4.1 Calculated by: Schmidt Fire Protection 99857 via daroca san diego, ca 92129 United States Phone-.8582796122 Fax: 8589273583 Designed By: James lnahara I I I I I I I I Project Name: VIASAT N4 T.I. Project Number: SH-1315 System Constraints I Name of Hazard Storage Pressure (psig): Initial Cyl. Storage Temperature (F) I Qty of Main Cylinders: Qty of Reserve Cylinders: Total Amount of Agent (Ibs): I Altitude Relative to Sea Level (ft): Type of Cyinder: FIRST FLOOR MDF RM-1.076 360 PSI Calculation Report Date: 4/30/2020 700 Calculation Revision: 1 Mid Discharge Cyl.Pressure: 211 PSIG 0 Cylinder Fill Density (lbs/cu.ft.): 53.58 62 Percent of Agent in Pipe 11.86% 0 Average Discharge Time (sec): 9.02 Sv 80 Cylinder Cyl. Volume (Cu.ft.): 1.17 I Hazard Characteristics I Enclosure Name: Rm-1 .076 Fire Type: Class C Fire Design Concentration: 7 Hazard Temperature (F) 70.0 I I I I Page 1 (Continued) I @ LISTED LISTED Your gateway to a new kind of service. 'FIRE SYSTEMS® Janus Fire Systems FM-2C0 Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.11.4.1 Hazard Characteristics (Continued) Nozzle(s) Used: 301 1800 Nozzle, Brass Dimensions (ft): 15.33X 12.46 X 9.5 Total Volume (Cu.ft.): 1514.72 Total Agent Required 6189 lbs Piping Network lnut -- Section -- Cyl. ------------------------------ Pipe -----------------------------Tee or Cping/ Nozzle Start End Qty Length Elevation Sched. Size 90's Bends Valve Union Drill 1 2 1 0.00 2.67 SCH 40 1-1/4 0 0 None 0 0 2 3 0 0.50 0.00 SCH 40 1 0 0 None 1 0 3 4 0 7.25 7.25 SCH 40 1 1 0 None 0 0 4 5 0 13.16 0.00 SCH 40 1 2 0 None 0 0 5 301 0 1.50 -1.50 SCH 40 1 1 0 None 0 0.4531 Manifold Dead Leg: - Length: 0; Pipe Schedule: ; Pipe Size: Piping Network Results Section Pipe Size Length Elevation EQL Tee or Start Term Flow Start End (in) sch (ft) (ft) (ft) Valve (PSIG) (Ibs/sec) 1 2 1-1/4 SCH 40 .00 2.67 8.00 None 211 208 9.28 2 3 1 SCH 40 .50 .00 .94 None 208. 205 9.28 3 4 1 SCH 40 7.25 7.25 9.87 None 205 192 9.28 4 5 1 SCH 40 13.16 .00 18.41 None 192 173 9.28 5 301 1 SCH 40 1.50 -1.50 4.12 None 173 169 9.28 Page 2 (Continued) Your gateway to a new kind of service. LISTED USTED jANllS1 FIRE SYSTEMS® Janus Fire Systems FM-200 Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.11 .4.1 Nozzle Performance Nozzle ID Nozzle Size (inches) Stock Number Nozzle Type Drill Dia (inches) Drill Size Total Orifice Area (sq.in.) Discharged (Ibs) 301 1" 18503-104 1800 Nozzle, Brass 0.4531 29/64 .322 62.0 Hazard Concentration Summary Enclosure Name Enclosure Volume (cu.ft) Agent Required (Ibs) Agent Discharged (Ibs) Concentration Requested /Achieved Pass or Fail Rm-1.076 1814.72 61.89 62.0 7.00 7.01 Pass Venting Estimate Enclosure Leakage Relative Safety Max. Positive Max. Negative Pos. ELA Neg. ELA Name Area Known Humidity Factor Pressure - PSF Pressure - PSF (sq.in) (sq in) Rm-1.076 No 36% 1 5 5 24.2 47 I Design I Error Messages I 1. - Hydraulic calculation was successful. I 2. -Version dated 1/1/2012 - Pipe Sizes & Nozzle Diameters are fixed. The designer has determined that additional gas for tees, per NFPA 2001 5.5.3.1.1 is not required. I 5. - * System Is designed To meet Underwriters Laboratory design criteria. 6. - All agent requirements were calculated based On NFPA 2001, Table A.5.5.1(i). I Page 3 (Continued) I @ @ Your gateway to a new kind of service. LISTED USTED I FIRE SYS T EMS® Janus Fire Systems FM-200 Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.11.4.1 Statistics of Piping Used (Note: Only U.S Standard Values are used by the math module) Piping information for Pipe Type: -SCH 40 Pipe Metric English Metric English Metric Type of Size (in) Size (mm) ID (in) ID (mm) lbs/ft kgs/M Joint 1 25 1.049 26.6446 1.68 2.5001 Threaded 1-1/4 32 1.38 35.052 2.27 3.3781 Threadea Note: For Pipe Schedule(s): -SCH 40; these Pipes conform to ANSI A-53/A-1 06, grade A-ERW or better Data File: C:\Users\James\Desktop\SH-1315-MDF.JDF Page 4 (End of Report) Your gateway to a new kind of service. LISTED LISTED JA TIRE SYSTEMSO Janus Fire Systems FM-200 Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.11.4.1 Calculated by: Schmidt Fire Protection 99857 via daroca san diego, ca 92129 United States Phone: 8582796122 Fax: 8589273583 Designed By: James Inahara I I 111 I I I Project Name: VIASAT N4 T.I. Project Number: SH-1315 System Constraints I Name of Hazard Storage Pressure (psig): Initial Cyl. Storage Temperature (F) I Qty of Main Cylinders: Qty of Reserve Cylinders: Total Amount of Agent (Ibs): I Altitude Relative to Sea Level (ft): Type of Cylinder: 2ND FLOOR IDF-2.088 360 PSI Calculation Report Date: 4/30/2020 70.00 Calculation Revision: 1 Mid Discharge CyI.Pressure: 227 PSIG 0 Cylinder Fill Density (lbslcu.ft.): 37.16 43 Percent of Agent in Pipe 26.11% 0 Average Discharge Time (sec): 9.07 Sv 80 Cylinder Cyl. Volume (Cu.ft.): 1.17 Hazard Characteristics Enclosure Name: ldf Room 2.088 Fire Type: Class A Fire Design Concentration: 6.7 Hazard Temperature (F) 70.0 Page 1 (Continued) I @ @ Your gateway to a new kind of service. USTED USTED I N, -FIRE SYS T EMS® Janus Fire Systems FM-200 Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.11 .4.1 Hazard Characteristics (Continued) Nozzle(s) Used: 302 - 900 Nozzle, Brass Dimensions (ft): 11.6 X 11.98 X 9.5 I Total Volume (Cu.ft.): 1320.196 Total Agent Required: 42.96 lbs Piping Network Input -- Section -- Cyl. ---------- - - - - - Pipe -----------------------------Tee or Cping/ Nozzle Start End Qty Length Elevation Sched. Size 90's Bends Valve Union Drill 1 2 1 0.00 2.67 SCH 40 1-1/4 0 0 None 0 0 2 3 0 0.50 0.00 SCH 40 1 0 0 None 1 0 3 4 0 7.25 7.25 SCH 40 1 1 0 None 0 0 4 5 0 8.83 0.00 SCH 40 1 2 0 None 0 0 5 302 0 13.00 13.00 SCH 40 1 1 0 None 0 0.4375 Manifold Dead Leg: - Length: 0; Pipe Schedule: ; Pipe Size: Piping Network Results Section Start End Pipe Size (in) sch Length (ft) Elevation (ft) EQL (ft) Tee or Valve Start Term (PSIG) Flow (Ibs/sec) 1 2 1-1/4 SCH 40 .00 2.67 8.00 None 227 226 5.00 2 3 1 SCH 40 .50 .00 .94 None 226 225 5.00 3 4 1 SCH 40 7.25 7.25 9.87 None 225 219 5.00 4 5 1 SCH 40 8.83 .00 14.08 None 219 216 5.00 5 302 1 SCH 40 13.00 13.00 15.62 None 216 205 5.00 Page 2 (Continued) @ @ Your gateway to a new kind of service. LISTED USTED -FIRE SY _ "- STEMS Janus Fire Systems FM-200 Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.11 .4.1 Nozzle Performance Nozzle ID Nozzle Size (inches) Stock Number Nozzle Type Drill Dia (inches) Drill Size Total Orifice Area (sq.in.) Discharged (Ibs) 302 1" 18496-103 900 Nozzle, Brass 0.4375 7/16 .150 43.0 Hazard Concentration Summary Enclosure Enclosure Agent Agent Concentration Pass or Name Volume (cu.ft) Required (Ibs) Discharged (Ibs) Requested / Achieved Fail ldf Room 2.088 I 1320.196 42.96 43.0 6.70 6.70 Pass Venting Estimate I Enclosure Leakage Relative Safety Max. Positive Max. Negative Pos. ELA Neg. ELA Name Area Known Humidity Factor Pressure - PSF Pressure - PSF (sq.in) (sq in) ldf Room 2.088 No 36% 1 5 5 16.7 32.5 Design I Error Messages I 1. - Hydraulic calculation was successful. I 2. -Version dated 1/1/2012 - Pipe Sizes & Nozzle Diameters are fixed. The designer has determined that additional gas for tees, per NFPA 2001 5.5.3.1.1 is not required. I 5. - * System Is designed To meet Underwriters Laboratory design criteria. 6. - All agent requirements were calculated based On NFPA 2001, Table A.5.5.1(i). Page 3 (Continued) I Your gateway to a new kind of service. LISTED LISTED I Li I I I FIRE SYsTEMs Janus Fire Systems FM-200 Hydraulic Flow Calculation Program Result Printout Calcu!ation Program Version 2.11.4.1 Statistics of Piping Used (Note: Only U.S Standard Values are used by the math module) Piping information for Pipe Tye: -SCH 40 Pipe Metric English Metric English Metric Type of Size (in) Size (mm) ID (in) ID (mm) lbs/ft kgs/M Join: 1 25 1.049 26.6446 1.68 2.5001 Threaded 1-1/4 32 1.38 35.052 2.27 3.3781 Threaded Note: For Pipe Schedule(s): -SCH 40; these Pipes conform to ANSI A-531A-1 06, grade A-ERW or better Data File: C:\Users\James\Desk'top\SH-1315-IDF.JDF Page 4 (End of Report) @ @ Your gateway to a new kind of service. LISTED LISTED DSI004 Reuisud: I7-Feb-2016 SV SERIES FM-200® FIRE EXTINGUISHING SYSTEM The Janus Fire Systems® Sv Series Clean Agent Fire Extinguishing System utilizes FM-2000 as the extinguishing medium. FM-2000 is a colorless, non-toxic gas perfectly suited to protect high value assets in areas that may be normally occupied, in locations where clean-up of other agents is problematic, when storage space for a fire suppression agent is restricted, or when an electrically non-conductive agent is required. Each system consists of the following components and their as- sociated accessories: FM-2000 Storage Components - Storage components consist of the cylinder assembly(s), which contains the FM-2000 chemical agent, and the cylinder bracket(s), which holds the cyl- inder assembly securely in place. FM-200® Distribution Components - Distribution components consist of the discharge noz- zles used to introduce the FM-2008 agent into a protected hazard along with the associated piping system used to connect the nozzles to the cylinder assembly. Trim Components - Trim components complete the installation of the FM-2000 system and consist of the electric valve actuator and the manual valve actuator. Slave Arrangement Components - Slave arrangement components consist of the pneumatic valve actuator(s), actuation check valve, vent check, actuation hose, and fittings required for a multiple cylinder (slave) arrangement. Supplemental Components - Supplemental components include the discharge pressure switch and manifold check valve. They supplement the core equipment or complete a specific multi-cylinder configuration. Control Panel - This device monitors the condition of the electric actuator, detectors, warning devices, cylinder pressure, and any manual release and abort stations. All electric or electronic devices must connect to the control panel in order to function. Early Warning Detection and Alarm Devices - Early warning detection devices coupled with manual release and abort stations maximize system efficiency while audible and visual alarm devices alert staff of alarm conditions. USTED LISTED ®ppg® Typical Clean Agent System Layout Li Warning Electric Valve / Actuator Smoke Detector Discharge No I 4 - -_ yin der Valve] / fControl Panel I Manual Release & Abort Cylinder Bracket Agent Storage Cylinder I © 2008 Janus Fire Systems. All rights reserved (5/2008) Janus Design Suite® and Janus Fire Systems® are registered trademarks of Janus Fire Systems. FM-2008 and Teflon& are registered trademarks of F. I. du Font de Nemoura and Company. Cylinder Valve Dip Tub Cylinder Bracket Cylinder EQUIPMENT DESCRIPTION The FM-200® agent is stored as a liquid in cylinder assemblies designed specifically for the ap- plication and charged to a fill density of between 35 lb/ft' (561 kg/m') and 70 lb/ft' (1121 kg/m'). To ensure optimal performance, each cylinder is superpressurized with dry nitrogen to 360 psi (24.8 bar) at 70°F (21°C). An identification label is affixed to the cylinder body indicating the fill quantity of FM-200®, charging pressure, date of fill, and fill station. The Sv Series supports three cylinder capacities. FM-2000 fire extinguishing systems are designed to be discharged within 1 J seconds into a room, area, or enclosure with the structural integrity to retain the agent. The FM-2000 uniformly mixes throughout the protected area, achieving a minimum concentration level in accordance with NFPA 2001 and/or agency listings. Fill Capacity - jT — lrnil,iH 'Irrial!iii WeightIi Nominal Siz _ 401b 18583 18586 22 10.0 43 19.5 36 16.3 80 lb 18584 18587 41 18.6 81 36.7 65 29.5 13011b 18585 18588 66 29.9 131 59.4 77 - 35.0 The cylinder assembly is composed of a cylinder, dip tube, and cylinder valve. Cylinder Valve: The automatic release of FM-2000 is controlled by a forged brass, differential pressure operated cylinder valve conneced to the neck of the cylinder. The valve assembly is shipped with an anti- recoil safety plug installed in the discharge outlet and chained to the cylinder valve. Dip Tube: A threaded, rigid dip tube extends from the cylinder neck down to its bottom. Cylinder: The light walled, welded seam cylinder is manufactured according to the requirements of the U.S. Department of Transportation (USD01) and Transport Canada (TC) for compressed gas. Internal neck threads allow connection of the cylinder valve. The cylinder is designed for mounting in a vertical po- sition only. Page 2 of 10 D51004 Rovied: 17-Feb-2015 Valve Actuation The cylinder valve has four key features: Connection , Valve Actuation Connection: A threaded connection located on top of the cylinder valve serves as the at- tachment point for the electric (primary) or pneumatic (slave) valve actuator. Di tietrçe ACUfofl Pressure Gauge: A pressure gauge is affixed to the : Port cylinder valve exterior as shown on the cylinder valve assembly diagram. Low-Pressure Supervisory Switch: A low-pressure 1Ilrj supervisory switch is mounted to the cylinder valve as shown on the cylinder valve assembly diagram. Rupture Disc: A frangible rupture disc is fitted to the Low-Pressure Supervisory Switch cylinder valve body. It functions as an emergency re- lief device in the event of excessive pressure within Pressure Gauge the cylinder. Its rupture point is between 850 psi (58.6 Anti-Recoil Pilot Actuation j Discharge Outlet bar) and 1000 psi (68.9 bar). Safety Plug Port The cylinder valve has two outlets: Pipe Plug Discharge Outlet: A1 1/4 in (32 mm) FNPT connection serves as the connection point for discharge piping. Safety cap Rupture Disc Low-Pressure Supervisory Switch CYLINDER MOUNTING Pilot Actuation Port: A 3/8 in (10 mm) FNPT connec- tion (shipped with a removable plug) provides a means of applying actuation pressure to the slave cylinder(s) or, in a single cylinder system, the discharge pressure switch. The port is pressurized only during the 10 sec- and discharge period. Wall Mount Cylinder Bracket Assembly (PIN 18595) Cylinder stability is ensured by the cylinder bracket as- sembly, consisting of one strap and rail with accompany- ing bolts, nuts, and washers. The rail is slotted for ease of mounting with fasteners provided by the installer. 23.83 605 36.56 929 53.0 1346 19.93 506 32.67 830 49.10 1247 13.63 346 15.75 400 30.75 781 10.0 254 10.0 254 10.0 254 11.9 302 11.9 302 11.9302 Page 3 of 10 0S1004 Revised: 17-Feb-2e16 1 1/4' Elbow (32 mm) Recommended (Provided by - Installer) / 1 1/4 Discharge Nipple Outlet (32 mrr Recomme -imi (Pro vdec' by Instshe- I /4" Union (32 mm) Recommended (Provided by 1111" Installed Nipple (32 mm) Presume Recommended Gauge (Provided by Added O Installer) y.inda Valve Anti-Recoil Safety Plug Shipped auth Cylinder Valve " Cylinder Valve Assembly with Trim Components Manual Valve Actuator 1701)1) Eletric Valve Actuator (ml Superiissry Limit Switch - P/N 20722) (w/o Supervisory Limit Switch- P/N 18481) Rupture Osc Affixed to Cylinder Vtiva Pilot Auation . Suserviscry Switch Affixed to Cylinder Valve CYLINDER VALVE FEATURES 18' (457 mm) Leads Discharge Outlet I Connections The discharge outlet of the cylinder valve is a 1 1/4 in (32 mm) female NPT connection that is Lsed to attach the cylinder to the discharge piping system. The suggested pipe configuration is shown to the left. Pipe and fittings are to be supplied by the installer. Low-Pressure Supervisory Switch (PIN 17032) The Tow-pressure supervisory switch continuoyiy1ioni- th contacts tors the prizQof the cylinder. The rTtac configu- ration is single pole, le thro pressure rated 1.5 Amps at 24 VCC uld the cylindel switch con- drop to approximate 0 psi (19. the tacts will cbs Ir itting a signal to the em control panel. mounted to the cylinder valve and ca ep1ed while under pressure. Pressure Gauge (P/N 17556) NFPA 2001 mandates a pressure gaug2 for each cylinder as a method of visually monitoring the internal pressure condition of the cylinder assembly. The press-re gauge is mounted to the cylinder valve and carnot be replaced while under pressure. Page 4 of 10 Emergency Release Button 1/7(1 Conduit C.., with 36 (914 mm) Leads snurrea Swivel Nut CS 1004 Revised: 17-Feb-2015 TRIM COMPONENTS Trim components are required to operate the FM-2000 cylinder(s). Eltrk Valve Acttiafnr wl Supervisory Limit Switch' (P/N 20722) I w/o Supervisory Limit Switch (P/N 18481) The electric valve actuator attaches to the primary cylinder at the valve actuation connection and is utilized to automati- cally open the cylinder valve upon receipt of a signal from the control panel or other source. It operates between 17 and 30 VDC and consumes 500 mA (.5 Amps) at 24 VDC nominal with a maximum supervisory current of 30 mA (0.03 Amps). The electric valve actuator body is steel construction with a brass knurled swivel nut and a stainless steel actuation pin that depresses the valve core when energized. In the model with supervisory limit switch, the switch contacts are normally closed when the actuator is not installed onto the cylinder valve and open when the actuator is fully installed onto the valve actuation connection at the top of the cylinder valve. Manual Valve Actuator (P/N 17001) An optional manual valve actuator attaches to the top of the electric valve actuator and provides a means to manually open the cylinder valve. The manual valve actuator consists of a brass body, stainless steel actuation pin, and steel safety ring pin. To discharge the primary cylinder manually, the ring pin is re- moved and the emergency release button is depressed forc- ing the pin in the electric valve actuator to depress the valve core of the cylinder valve. All other connected cylinders will be opened pneumatically. SLAVE ARRANGEMENT COMPONENTS to 16 cylinders (1 primary and 15 slave) may be installed in a single arrangement, with a maximj1 tending from the primary cylinder i ither directio'.typical arrangement is shown below. Actuation n. Flex Hose Mid Pressure Switch Use Tee 16 Flex Hos Discharge M staller Pilot Discharge Variable Size Pilot old lengthof 100 ft (30.48 m) of pilot actuation hose or tubing ex (P/N 186 (Provided (P/N 8625) (P/N 18611) (P/N 18773) (PIN 17019) Mel Variable) (P/N 18622) ,_7 Pneumatic 1" / Male NPT Male NPT Actuation Adapler _.__., Valve Actua "N. Valve Actuator / Adapter End Line Tee (P/N 18625) (P/N 17001) 4 / 1 1/Manifold 4" (32 mm) Check Valve (PIN 18547) Vest Check /7 . Electric Valve Actuator - -, (P/N 10173) w/ Supervisory Limit Switch (PIN 20722) w/o Supervisory Limit Switch (PIN 18481) Pilot Actuation Adapter - • (PIN 18624) Pilot Actun - 18560) r6lb EW- 5111111 ai '7 Primary Slave Slave Slave Slave Cylinder cylinder Cylinder Cylinder Cylinder Typical Primary and Slave Cylinder Arrangement Page 5 of 10 NFPA 2001, 2012 Edition, requires that the removal of an electric actuator from the agent storage container discharge valve that it controls shall result in an audible and visual indication of system impairment at the system releasing control panel. This will become effective January 1, 2016. 3/8" (10 mrr MNPT 1/4' (8 mm) 37" Male JIC 1/4' (8 mm) MNPT 1/4" 8 mm) FNPT t 1/4" (8 mm) MN 2T 1/4" (8 MM) 37" Male JIC 031OO4 Revised: 17-Feb-2C15 1;4 (8 mm) FNPT Knred N OH 4" (8 mrr MNPT Pneumatic Valve Actuator (PIN 17019) On multiple cylinder systems the electric valve actuatr will open the primary cylinder and then, in a rapidly"oc- curling sequence, the pneumatic va/ eh, r) will open all other cylinders using pressurthe rimary cylinder. A pneumatic valve actuator attach alve ac- tuation connection of each slave cy eceives pressure from the pilot actuation por ary cyl- inder through the pilot actuatioi chec is brass with a brass piston and pin. Vent Check (P/N 10173) The vent check is a safety çlevice with 1/4 in (8 mm) MNPT threads that is to be ip'stalled in the pilot actuation line downstream of the piØ't actuation check valve. It is used to bleed off presse that may accumulate in the pilot actuation hose or minimizing the chance of inadvertent pressuriz,$'tion of the pneumatic actuators or discharge pressure ,,witch. Pilot Actuatiçvh Check Valve (PIN 18560) A A 1/4 in (8 m) MNPT by 37° male JIC check valve is ins lied in he pilot actuation port of the primary cylinder witirection of flow OUT of the valve. When the , pressure will be directed through the pilot ac- k valve to the pneumatic valve actuators on the ers. The purpose of the pilot actuation check sure the pneumatc actuator(s) remain pIes- entire discharge period. Pilot Actuation Aapter (PIN 18624) A 3/8 in (10 mm) MN by 1/4 in (B mm) FNPT brass pipe bushing is fitted in the pilot actuation port of the primary cylinder to facilite the attachment of the pilot actuation check valve. \ Pilot Actuation Mid Line Tee (R(N 18622) A 114 in (8 mm) 37° male JIC by MNP\brass branch tee is utilized to attach the pilot actuation 1ie to the pneu- matic valve actuator. \ Male NPT Adapter (PIN 18625) \1ine. A 1/4 in (8 mm) 37° male JIC by MNPT adapte the pilot actuation end line tee of the final slave to facilitate the attachment of the pilot actuati also may be utilized to allow the attachment of to the discharge pressure switch. 1/4" (8 mm) 1/4" (8 mm) 37" Male JIC MNPT Page 6 of 10 DSI004 RevIsed: 17.reb_2C16 j(8 Pilot Actuation End Line Tee (PIN 18611) A 1/4 in (8 mm) FNPT by MNPT brass branch tee r9unts to the final pneumatic valve actuator to facilitate/attach- ment of the vent check to the pilot actuation Iin ) 1/4' (8 mm) FNPT \________ MNPT Flex Hose (PIN See Chart) steel wire braided hoses of varyinths with 1/4 in Flex hoses are 3/16 in (7 mm) Teflo ® lined stainless (8 mm) 37° female JIC flare fittingI They are utilized to - \ — - interconnect cylinders when a sJve arrangement is re- m quired. A 1/4 in (8 mm) 37° r$le JIC flare x male JIC \ flare adapter (P/N 18777) is ailable to connect lengths of flex hose together. / mm) 18649 mm 18650 m 18651 6 18648 Vsysarrangmements. m) SUPPLEMENTAL COM Supplemental components comple ngements. Dcharge Piessure Switch (PIN 18773) / The discharge pre'sure switch is used in the system to / provide positive indition of agent discharge and to initi- ate the shut down of \quipment that may deplete agent concentration. The pres\ure switch is a single pole, dou- Con it ble throw (SPDT) switch th contacts rated 10 Amps re- sistive at 30 VDC. \ 1/4" (8 n FNPT P1 Manifold Check Valve (P/N 18547) 5.2 (133-mm) 1 1/4' (32 mm) FNPT In a multiple cylinder arrangement where the lave and primary cylinders share a common manifold or'¼ a main I reserve arrangement, a 1 1/4 in (32 mm) FNP\mani- fold check valve must be placed between the discharge outlet of each cylinder and the discharge manifold toe- vent back flow from the manifold should the system inadvertently discharged when one or more cylinders are disconnected for maintenance. The take-out for the valve is 1.375 in (35 mm). Page 7 of 10 DS1004 Revised I7Feb-2016 DISCHARGE NOZZLES Discharge nozzles (1, 2, or 4 ports) ar- used to uniformly distribute the FM-2-D0 agent. They are performance tested to ensure that tie agent is discharged within 10 se:onds and properly dispersed throughout the protected arc t. Maximum nozzle height for a prctecte space is 16 ft (4877 mm) per tier of nozzles. Additioral tiers are required for heights greater than 16 ft. T t195 &q Discharge Nozzle Cut View 84 19.SMI 0 Discharge Nozzle Top View - - 360° Radial Nozzle (4 'ort) Arrancement 900 Corner Nozzle (1 Port) 1W I19.5M1 12" 1305eirn1 Mø.xI4lJ! 180° Sidewall Nozzle 2 Port: Arrangement 37 (LT5MI T\ 4&25F- 113.79M 32° MAXIMUM j7 5M TMJM IMXD1UM 90° Corner Nozzle (1 Port) Arrangement T L15 I 3600 Radial Nozzle (4 Port) 1800 Sidewall Nozzle (2 Port) Page 8 of 10 9.0 90,000 5.00 9.5 95,000 5.00 - 10.0 100,000 5.00 10.5 105,000 5.00 11.0 110,000 1.13 11.5 115,000 0.60 12.0 120,000 0.49 0S1004 Reved: l7-'eb-2 6 18507 18500 18493 18796 18789 18782 318 in (10mm) 1.436 36.5 18508 18501 18494 18797 18790 18783 1/2in(l5mm) 1.722 43.7 18509 18502 18495 18798 18791 18784 3/4 in (20 mm) - 1.926 48.9 185101 18503 18496 118799 18792 18785 1 in (25 mm) 2.176 55.3 18511 18504 18497 18800 18793 18786 1 1/4 in (32 mm) 2.500 63.5 18512 18505 18498 18801 18794 18787 1 1/2in(40mm) 2.689 68.3 18513 18506 18499 18802 18795 18788 2 i (50 mm) 3.100 78.7 • Ordering Instructions: Specify the Nozzle P/N followed by a dash and the three digits representative of the drill code as provided by the Janus Design Suite® software. Example: 18507-XXX = Nozzle: 360°, 3/8' (10 mm), Brass (with drill code as specified) FM-200® CHEMICAL PROPERTIES FM-2000 (HFC-227ea) is formed from the elements carbon, fluorine and hydrogen (CF3CHFCF3 - heptafluoropropane). The primary extinguishing mechanism of FM-2000 is heat absorption, with a secondary chemical contribution from the thermal decomposition of FM-2000 in the flame. FM-2000 leaves no residue and is safe for use in occupied spaces. Most common metals, such as aluminum, brass, steel, cast iron, lead, stainless steel, and copper, as well as rubber, plastic, and electronic components, are unaffected when exposed to FM-200®. SAFETY CONSIDERATIONS Although the EPA Significant New Alternative Program (SNAP) lists FM-2000 as acceptable for oc- cupied spaces, NFPA Standard 2001 and SNAP list the following guidelines for human exposure: The discharge of FM-2000 into a hazard may reduce visibility for a brief period. FM-2008 may cause frostbite if liquid discharge or es- caping vapor contacts the skin. When FM-2000 is exposed to temperatures greater than 1300°F (700°C), the by-product Hydrogen Fluoride (HF) will be formed. FM- 2000 systems are designed to discharge in 10 seconds or less in order to minimize the amount of HF formed. The FM-2000 Material Safety Data Sheet (MSDS) should be read and understood prior to working with the agent. A cylinder containing FM-200® should be han- dled carefully. The anti-recoil safety device must be in place at all times when the cylin- der is not connected to the discharge pip- ing and restrained. Page 9 of 10 D31004 Revised: 17-Feb-2015 Cylinder Assembly, FM-200, 40 lb Ila 1.19 11% (22 to 43 lb /10.0 to 19.5 kg capacity) 18584' Cylinder Assembly, FM-200, 80 lb 65(29.5) (41 to 81 lb /18.6 to 36.7 kg capacity) Cylinder Assembly, FM-200, 130 lb (66 to 131 lb 129.9 to 594 kg capacity) I FM200AGENT FM-200® Bulk Variable 18595 Bracket Assembly, Cylinder, 10" (40 lb I 80 lb / 130 Ib) 10.0(4.5) 20722 Electric Valve Actuator wl Supervisory Limit Switch (primary cylinder) 2.0 (0.9) 18481 Electric Valve Actuator w/o Supervisory Limit Switch (primary cylinder) 2.0 (0.9) 17001 Manual Valve Actuator (primary cylinder) 0.6 (0.3) I 18560 Valve, Check, 1/4" JIC Male x 114" MNPT PilotActuation Check Valve 0.3(0.1) 18624 Bushing, 3/8" MNPT x 114" FNPT, Brass Pilot Actuation Adapter 0.2 (0.1) 18622 Tee, 1/4" JIC Male x 1/4" MNPT, Brass PilotActuation Mid Line Tee 0.2(0.1) 10173 Vent Check (connects to Pilot Actuation End Line Tee) 0.2(0.1) 18625 Adapter, 1(4" MNPT x 1/4" JIC Male, Brass 0.2(0.1) Male NPTAdapter (conrects to Pilot Actuation End Line Tee 18611 Tee, 1/4" FNPT x 1/4" MNPT, Brass Pilot Actuation End Line Tee 0.3 (0.1) - 18773 Switch, Discharge Pressure 1.4(0.6) 18547 Valve, Check FNPT, 1-14" (32 mm) Manifold Check Valve 6.0 (2.7) 18648 Hose, Flex, 316", 1/4" JiC Female, 16" long 0.6(0.3) - (recommended for 40 1 801130 lb cylinder arrangements) 18777 Adapter, 1/4" JIC Male x 1/4" JIC Male, Brass Flex Hose Adapter 0.2 (0.1) Variable Nozzle, 3/8", FM-200 0.5 (0.2) Variable Nozzle, 1/2", FM-200 0.6(0.3) Variable Nozzle, 314", FM-200 0.8 (0.4) Variable Nozzle, 1", FM-200 1.2 (0.5) Variable Nozzle, 1-1/4", FM-200 - 1.6 (0.7) Variable Nozzle, 1-1/2", FM-200 1.7 (0.8) Variable Nozzle, 2", FM-200 3.6(l.6) Specify the Cylinder Assemb'y P/N followed by a dash and the fill weight in pounds expressed in three digits Example: 18583-039 - CylinderAssembly, FM-200, 40 lb (39 lb fill) The seller makes no warranties, express o implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. (47-,JAN__US FIRSTEMS 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: infoijanusfiresystems.com www.janusfiresystems.com Page 10ot 10 Arm IA-rp (PN 17001) JATOR (PN 18481) N 17011) LISTINGS: -FM TECHNICAL DATA: -APPLICATION: CYLINDER IS USED TO HOUSE THE FM 200 AGENT. )ER LABEL (PN 18490) -RATED WORKING PRESSURE: 520 PSI AT 130 OF [35.9 BAR AT 54.4 AC] -WEIGHT: SEE TABLE -TEMPERATURE RANGE (INDOOR & OUTDOOR): 32 IF TO 130 IF [0 AC TO 54.4 'Cl MATERIAL: -BODY: CYLINDER BODY IS HIGH SPUN CARBON STEEL AND THE VALVE IS BRASS. -FINISH COLOR: RED CYLINDER WITH FM 200 CYLINDER BRASS VALVE. STOCK NO. I SIZE I DIM 'A' I DIM 'B' I DIM 'C I MIN FILL WEIGHT I MAX FILL WEIGHT I VALVE SIZE I 18583 40 LB FM 200 29-9/16 in I 20-1/8 in [510.4 171 4 mml I mml 10 in [254 mm] 22 LB [10 KG] 43 LB [19.5 KG] Sv 18584 11 1 80 LB FM 200 42-5/16 in [1074.8 mm] I 32-13/16 in [833.9 mm] 10 in [254 mm] 41 LB [18.6 KG] 81 LB [36.7 KG] Sv 18585 130 LB FM 200 1 [ .JLJJf -T III 1492.3 mm] I [ TJJ./ -r i, 1251.4 mm] 10 in [254 mm] 66 LB [29.9 KG] 131 LB [59.4 KG] 5v THE SELLEF MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, EXCEPT AS EXPRESSLY STATED IN THE SELLERS SALES CONTRACT SR SALES ACKNOWLEDGMENT FORM. EVERY ATTEMPT IS MADE TO KEEP OUR PRODUCT INFORMATION UP-TO-DATE AND ACCURATE. ALL SPECIFIC APPLICATIONS CANNOT BE COVERED NOR CAN ALL REQUIREMENTS BE ANTICIPATED. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DETAIL SHEEr NO. 570 NO. I REV #JANUS " DE DS-001 SEE TABLE I DESCRIPTION FIRE SYSTEMS FM 200 CYLINDER, Sv SERIES - -I 1-1/4 in NPT [32 mm] SUPERVISORY PRESSURE SWITCH (PN 13695) 1-1/4 in [32 mm] DISCHARGE OUTLET RELIEF VALVE 51%in - [134.1 mm] PRESSURE GAUGE (PM 17556) PUX[LA1RY OUTLET FOR SLAVE CYLINDER ACTUATION LISTINGS: -UL, FM, CE TECHNICAL DATA: -APPLICATION: FM 200 DISCHARGE VALVE, Sv SERIES. -RATED WORKING PRESSURE: 520 PSI [35.86 BAR] -BURST PRESSURE: 2000 PSI [137.93 EAR] -WEIGHT: 11.5 LB [5.68 KG] /8 in -TEMPERATURE RANGE (INDOOR & OUTDOOR): 0 °F TO 193.2 mm] 130 °F [-17.7 °C TO 54.44 °C] 3. MATERIAL: -BODY: YELLOW BRASS CA-377 -FINISH COLOR: SAME AS MATERIAL THE SELLER MARES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE -MPUED WARRANTIES 01 MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, EXCEPT AS EXPRESSLY STATED IN THE SELLERS SALES CONTRACTOR SALES ACKNOWLEDGMENT FORM. EVEA ATTEMPT IS MADE TO KEEP OUR PRODUCT INFORMATION UP-TO-DATE AND ACCURATE ALL SPECIFIC APPLICATIONS CANNOT BE COVERED, NOR CAN ALL REQUIREMENTS BE ANTICIPATED. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT '-ETICE, DETAIL SHEET NO. STOCR NO. REV #J ANUS DS-606 I 17011 2 FIRE SYSTEMS Th DESCRIPTION VALVE ASSEMBLY, FM 200, 1-1/4 in Sv SERIES i-ui---- i/3 in [41.2 mm] 1 i [25.4 mm] 1/ in [12.7 mm] 43/is in [106.0 mm] '/16 in [23.0 mn LISTINGS: -UL, FM TECHNICAL DATA: -APPLICATION: ELECTRIC ACTUATION OF DISCHARGE VALVE. USED IN FM200 AND NOVEC 1230 APPLICATIONS. -WEIGHT: 2 LB 0.9 KG -TEMPERATURE RANGE (CLEAN AGENT APPROVAL): 32°F TO 130°F [0°C TO 54.4°C] -OPERATING VOLTAGE (NOMINAL): 24 VDC -CURRENT: 500 mA @ 24 VDC, NOMINAL -MAXIMUM MONITORING CURRENT: 30 mA MATERIAL: -BODY: BODY IS CORROSION RESISTANT FINISH; PLU NGER AND PUSH BUTTON STEM ARE STAINLESS STEEL M] -FINISH COLOR: SAME AS MATERIAL NOTES: -WIRE LEADS ARE 36 in [914 mm] IN LENGTH. -BLACK WIRE IS NEGATIVE. -WHITE WIRE IS POSITIVE. -ACTUATOR IS SUITABLE FOR OUTDOOR APPUCAT IONS WHEN PROTECTED FROM THE ELEMENTS AND WHEN NOT EXPOSED TO TEMPERATURES BEYOND THE RANGE N OTED ABOVE. DY4lfl -J [6.4 mm] THE SELER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, AEJT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, EXCEPT AS EXPRESSLY STATED IN THE SELLER'S SALES CONTRACTOR SALES ACKNOWLEDGMENT FORM. EVERY ATTEMPT IS MADE TO KEEP OUR PRODUCT INFORMATION UP-TO-DATE AND ACCURATE. ALL SPECIFIC APPLICATIONS CANNOT RE COVERED, NOR CAN ALL REQUIREMENTS BE ANTICIPATED. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DETAIL SHEET NO. STOCK NO. REV #JANUS DS-107 18481 4 FIRE SYSTEMS '° DESCRIPTION ELECTRIC VALVE ACTUATOR, USED WITH CLEAN AGENT CYLINDERS, 24 VDC 21/ [5; _T in [22.9 mm] TECHNICAL DATA: -APPLICATION: USED IN FM 20C AND NOVEC 1230 APPLICATIONS TO ALLOW MANUAL ACTUATION OF CYLINDER VALVE. -WEIGHT: 0,6 LB [0.3 KG] -TEMPERATURE RANGE iINDOOR & OUTDOOR): -4°F TO 131°F [-20 °C TO 55°C] MATERIAL: -BODY: BRASS BODY, METAL PIN, PHENOLIC BUTTON -FINISH COLOR: BODY AND PIN IS SAME AS MATERIAL AND BUTTON IS RED. NOTES: -TO ACTUATE CYLINDER, PiLL SAFETY RING PIN OUT AND PUSH DOWN ON THE RED RELEASE BUTTON. i.i mmj THE SELLER RAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOLIWTSD TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, UTCEPT AU EXPRESSLY STATED IN THE SELLERS SALES CONTRACTOR SALES ACKNOWLEDGMENT FORM. EVERY ATTEMPT IS I-EASE TO KEEP OUR PRODUCT INFORMATION UP-TO-DATE AND ACCURATE. ALL SPECIFIC APPLICATIONS CANNOT BE COHERED, NOR CAN ALL REQUIREMENTS BE ANTICIPATED. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DETAIL SHEET NO. STOCK NO. REV #JANUS DS-101 I 17001 I FIRE SYSTEMSWI DESCRIPTION MANUAL VALVE ACTUATOR 1. LISTINGS: (SEE TABLE) E -UL, FM, CE (EN - 12094) D ft 2. TECHNICAL DATA: . H -APPLICATION: USED FOR FM200, HPCO2, AND LPCO2. ORIFICE SIZE DETERMINED -RATED WORKING PRESSURE: 2000 PSI [138 BAR] BY JANUS DESIGN SUITE. -WEIGHT: SEE TABLE -TEMPERATURE RANGE (INDOOR & OUTDOOR): -20 °F TO 130 °F [-29 °C TO 54 °C] B MATERIAL: -BODY: BRASS -FINISH COLOR: SAME AS MATERIAL NOTES: - 1 TC - THERE IS AN NPT FEMALE THREAD LOCATED ON THE BOTTOM OF THE NOZZLE. SEE TABLE FOR THREAD SIZE A AND DESIGNATION. - 3/8 in [10 mm] NOZZLE NOT AVAILABLE FOR CO2. - INSTALL NOZZLE UPRIGHT OR PENDANT. STOCK NO. SIZE DIM 'A' DIM 'B' DIM 'C DIM 'D' DIM 'E' WEIGHT THREAD TYPE 18500 3/8 in 1 1/8 in [28.6 17/16 in [36.5 3/8 in [9.5 mm] 13/16 in [20.6 1 1/16 in [27 0.5 LB 3/8 in - 18 NPT 110 mm] mm] mm] mm] mm] [0.2 KG] 18501 1/2 in 1 1/4 in [31.8 13/4 in [43.7 3/8 in [9.5 mm] 15/16 in [24.2 13/16 in [30.6 0.6 LB 1/2 in - 14 NPT [15 mm] mm] mm] mm] mm] [0.3 KG] 18502 3/4 in 1 1/2 in [38.1 1 15/16 in [48.9 1/2 in [12.7 mm] 11/8 in [29.4 13/8 in [35.7 0.8 LB 3/4 in - 14 NPT rn mml mml . 1 [ 18503 j i 23/16n,Ifl][553 1/21n[127mm] 13/8in353 15/8 in 417 '] 1 i 115 NPT I 18504 - -, mm] [3 mm] -, mm] - -, - mm] 5/8 in [15.9 mm] L mm] 2 in [50.8 mm] 10.7 KG] 1 1/4 in - 11.5 NPT 18505 1 1/2 in 2 1/4 in [57.2 2 11/16 in [68.3 5/8 in [15.9 mm] 2 in [50 mm] 2 1/4 in [56.4 1.7 LB 11/2 in -11.5 NPT [40 mm] mm] mm] mm] 10.8 KG] 18506 2 in [50 3 in [76.2 mm] 3 1/8 in [78.7 5/8 in [15.9 mm] 2 7/16 in [61.9 2 11/16 in [68.3 3.6 LB 2 in -11.5 NPT mm] mm] mm] mm] [1.6 KG] THE SELLER MAKES NO WARRANTIES, DEPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, EXCEPT AS EXPRESSLY STATED IN THE SELLER'S SALES CONTRACI' OR SALES ACKNOWLEDGMENT FORM. EVERY ATTEMPT ID MADE TO KEEP OUR PRODUCT INFORMATION UP-TO-DATE AND ACCURATE. ALL SPECIFIC APPLICATIONS CANNOT BE COVERED, NOR CAN ALL REQUIREMENTS BE ANTICIPATED. ALL SPECIFICATIONS ARE SUBJECT TO CHANCE WITHOUT NOTICE. #JANUS DETAIL SHEET NO. DS-702 STOCK NO, SEE TABLE I REV I FIRE SYSTEMS Th DESCRIPTION NOZZLE, 180°, BRASS I [1 AGENT FLOW DIRECTION DESIGNATED BY ARROWS 900 n AGENT FLOW DIRECTION DESIGNATED BY ARROW I TOP OF 1. TYPE LISTINGS: (SEE (SEE TABLE) -UL, FM, CE (EN - 120) _____________ ________ L TECHNICAL DATA -APPLICATION: USED FOR FM200, HPCO2, AND LPCO2. -RATED WORKING PRESSURE: 2000 PSI [138 BAR] O.IFICE SIZE DETERMINED BY JANUS DESIGN SUITE -WEIGHT: SEE TABLE -TEMPERATURE RANGE (INDOOR & OUTDOOR): -20 °F TO 130 °F [-29°C TO 54°C] B MATERIAL: -BODY: BRASS -FINISH COLOR: SAME AS MATERIAL NOTES: - THERE IS AN NPT FEMALE THREAD LOCATE) ON THE BOTTOM OF THE NOZZLE. SEE TABLE FOR THREAD ________________ SIZE AND DESIGNATION. - 3/8 in [10 mm] NOZZLE NOT AVAILABLE FO CO2. - INSTALL NOZZLE UPRIGHT CR PENDANT. STOCK NO. SIZE DIM A' DIM 'B' DIM 'C' DIM 'D' DIM 'E' WEIGHT THREAD TYPE 18493 3/8 in 1 1/8 in [2E.6 17/16 in [36.5 3/8 in [9.5 mm] 13/16 ii [20.6 1 1/16 in [27 0.5 LB 3/8 in - 18 NPT [10 mm] mm] rrm] mm] mm] 0.2 KG] 18494 1/2 in 11/4 in [3L8 13/4 in [43.7 3/8 in [9.5 mm] 15/16 h [24.2 13/16 in [30.6 0.6 LB 1/2 in - 14 NPT 115 mm] mm] mm] mm] mm] 1-0.3 KG] 18495 3/4 in 1fl mm] 11/2 in [3.1 mml 115/16 in [48.9 rrm] 1/2 n [12.7 mm] 1 1/8 in [29.4 mm] 13/8 in [35.7 mml 0.8 LB [fl 4 3/4 in - 14 NPT 18496 tin [25 13/4 in [44.5 2 3/16 in [55.3 ___ 1/2 n [12.7 mm] 13/8 in [35.3 15/8 in [41.7 1.2 LB tin - 11.5 NPT mm] mm] mm] mm] mm] [0.5 KG] 18497 11/4 ii [32 mm] 2 1/4 u []71 mm] 21/2ii [G3. rim] 5/8 in [15.9 mm] 1 3/4 .3 mm 2 in [50.8 mm] 1.G LB [0.7 KG] i NPT 18498 1 1/2 in 2 1/4 in [57.2 2 11/16 in [68.3 5/8 n [15.9 mm] 2 in [50 mm] 2 1/4 in [56.4 1.7 LB 11/2 in -11.5 NPT [40 mm] mm] mm] mm] [0.8 KG] 2 in [50 3 1/8 in [78.7 2 7/16:n 61.9 2 11/16 in [68.3 3.6 LB 18499 mm] 3 in [76.2 mm] mm] 5/8 n [15.9 mm] mm mm] [1.6 KG] 2 in -11.5 NPT THE SELLER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT U'IITEJ TO, THE IMPLIED WARRRWIES OF MERCHANTAEIUTS AND FITNESS FOR A PARTICULAR PURPOSE, EXCEPT AS EXPRESSLY STATED IN THE SELLER'S SALES CONTRACT OR SALES ACKNOWLEDGMENT FORM. EVERY ATTEMPT IS MADE TO KEEP TOE °RODUCT INFORMATION OP-TO-DATE AND ACCURATE. ALL SPECIFIC APPLICATIONS CANNOT RE COVERED, 'LEA CAN ALL REQUIREMENTS BE ANTICIPATED. ALL SPECIFICATIONS ARE SUBJECT TO CHAN SE WITHOUT NOTICE. #J ANUS I TVTOIL SHEET NO, DS-701 STTCTK NO. I SEE TABLE REV I FIRE SYSTEMSTh CESTRIPTION NOZZLE, 90°, BRASS AGENT FLOW DIRECTION DESIGNATED BY ARROW I TOP OF NOZZLE 1. LISTINGS: (SEE TABLE) E -UL, FM, CE (EN - 12094) D 2. TECHNICAL DATA: -APPLICATION: USED FOR FM200, HPCO2, AND LPCO2. -RATED WORKING PRESSURE: 2000 PSI [138 BAR] ORIFICE SIZE DETERMINED BY JANUS DESIGN SUITE. -WEIGHT: SEE TABLE -TEMPERATURE RANGE (INDOOR & OUTDOOR): -20 OF TO 130 OF [-29 oC TO 54 °CJ MATERIAL: -BODY: BRASS -FINISH COLOR: SAME AS MATERIAL NOTES: - THERE IS AN NPT FEMALE THREAD LOCATED ON THE BOTTOM OF THE NOZZLE. SEE TABLE FOR THREAD SIZE AND DESIGNATION. - 3/8 in [10 mm] NOZZLE NOT AVAILABLE FOR CO2. - INSTALL NOZZLE UPRIGHT OR PENDANT. STOCK NO. SIZE DIM 'A DIM 'B' DIM 'C' DIM 'D' DIM 'E' WEIGHT THREAD TYPE 18493 3/8 ii 1 1/8 in [28.6 17/16 in [36.5 3/8 in [9.5 mm] 13/16 in [20.6 1 1/16 in [27 0.5 LB 3/8 in - 18 NPT [10 mm] mm] mm] mm] mm] [0.2 KG] 1/2 ii 11/4 in [31.8 13/4 in [43.7 15/16 in [24.2 13/16 in [30.6 0.6 LB 18494 [15 mm] mm] mm] 3/8 in [9.5 mm] mm] mm] [0.3 KG] 1/2 in - 14 NPT 18495 3/4 ii 11/2 in [38.1 - 115/16 in [48.9 1/2 in 112.7 mml 11/8 in [29.4 - 13/8 in [35.7 - 0.8 LB 3/4 in - 14 NPT -.iiiiij I 18496--r in [25 .m1 - T 13/4 in [44.5 mm] 2 3/1 6 in [55.3 mm] 1/2 in [12.7 mm] 13/8 in [35.3 mm] 1 5/8 in [41.7 mm] 1.2 LB [0.5 KG] tin - 11.5 NPT 18497 L'-'-'-' 5/8 in [15.9 mm] '' ''' 2 in [50.8 mm] £ £ITE III - JJ [32 mm] mm] mm] mm] [0.7 KG] NPT 1 1/2 in 2 1/4 in [57.2 2 11/16 in [68.3 2 1/4 in [56.4 1.7 LB 18498 [40 mm] mm] mm] 5/8 in [15.9 mm] 2 in [50 mm] mm] [0.8 KG] 1 1 /2 in -11.5 NPT 2 in [50 3 1/8 in [78.7 2 7/16 in [61.9 2 11/16 in [68.3 3.6 LB 18499 mm] 3 in [76.2 mm] mm] 5/8 in [15.9 mm] mm] mm] [1.6 KG] 2 in -11.5 NPT THE SELLER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, EXCEPT AS EXPRESSLY STATED IN THE SELLER'S SALES CONTRACTOR SALES ACKNOWLEDGMENT FORM. EVERY ATTEMPT IS MADE TO KEEP OUR PRODUCT INFORMATION Up-TO-DATE AND ACCURATE. ALL SPECIFIC APPLICATIONS CANNOT BE COVERED, NOR CAN ALL REQUIREMENTS BE ANTICIPATED. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. #JAN 11 S DETAIL SHEET NO. DS-701 -NO, SEE TABLE I I REV FIRE SYSTEMS" DESCRIPTION NOZZLE, 900, BRASS 0S1317 Revised 15-0-2C17 ADDRESSABLE FIRE CONTROL PANEL Features 60 add esses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class A or Class B for SLC, P-Link and NACs 5 Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp Each, ideal for manual release and abort Strobe Synchronizaticr and System Wide Sync for Potter/AMSECO®, Gertex®, Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event History Buffer Cabinet will house up to 18 A batteries Optional two line DACT with UD-1000 that can report General, Zone or Point tnormation Built in IP Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information LISTED PIN 97681 Description The JFS-lP60 is an analog'addressable releasing fire alarm system with a total system capacity of 60 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compiant with the National Electri- cal Code (NEC). The JFS-lP60 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In additio-i, each output s uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes PottertAMSECO, Gertex, System Sensor and Coo- per/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The JFS-1P60 is listed for releasing of fire suppression systems. TI-c software allows cross zones, counting zones, and timers for suppression. The system s capable of rnitiple release outputs across multiple hazards. In addition, :he JFS-PS1000 may be used to extend releasing capability. The NACs may be expanded using the JFS-PS1000 series intelligent power supplies. Each JFS- PS1000 adds another 10 Amps of power, 2 additional nput circuits and the JFS-lP60 will support up to 31 power supplies. The system will synchronize The strobes sys:em wide. In addition, the JFS- PS1000E has space to aUow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. © 2017 Janus Fire Sysems All rights reserved (5/2017) Janus Fire Systems© is a registered trudemsrk of Janus Fire Systems. D01317 Revised: 15-Des-2017 16"Wx 17"H x 3 7/8°D 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA 5 Amps power for NAGs, I/O, and P-Link 3 Amps per NAC, regulated 1 Amp per I/O circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of 1 Amp 32° to 120° (0°C to 49°C) with a maximum humidity of 93% non-condensing. NFPA 12, 12A, 13, 15, 16, 171 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Station (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Automatic (A), Manual (M), Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev P01), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The sys- tem does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. SLC Loop Accessories The control panel may be connected with up to 60 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed• obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector. Analog Fixed Temperature Heat Detector that is selectable from 135°F to 185°F. Addressable Duct Smoke Detector with Form C Relay. Addressable Duct Smoke Detector. 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. - - - Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. Addressable Sounder Base that contains an addressable sounder module that may be con- figured for local, group and all call. Addressable CO gas detector. Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. I I I I I I I 1 I I I I I I I I I I I Page 2 of 6 D31 317 Revised: 15-Dev.2017 User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green • Alarm - Red • Earth Fault -Amber • Supervisory -Amber Silenced -Amber • Trouble -Amber • Pre-Release -Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. Ethernetll.P. Connection The JFS-1P60 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard Ill IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. P-Link The JFS-IP60 has a proprietary communication protocol that communicates through a RS-485 con- nection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: Analog/Addressable loop expansion module 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version avail- able. 16 LED annunciator with common indicators in a locked metal endosure. Flush mount version' available. 10 amp, remote intelligent power supply with 6 NAGs, 2 I/Os and a P-Link repeater. This panel is listed in conjunction with the JFS-lP60 as releasing circuits. Class A convertor that converts the SLC, NACs and P-Link connection JL listed, Dual line telephone alarm communicator - ED drier !Pander, used to connect up to 50 LEDs in a graphic display ire communication bdge, provides remote mounting of the Ethernet connection Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC 1e3['I,It Serial parallel gateway, allows for the connection to —a serial or parallel printer - Multi-Connect allows up to sixty-three IP series panels to share a single reporting technology. Two card expansion cabinet Eight cad expansion cabinet Fourteen card expansion cabinet *The FIB-1000, FCB-1000 and the SPG-1000 may oe installed in the stacker bracket or ordered with the op- tional rack mount enclosure. Page 3 of 6 051317 Revised 15.0€c.201' Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. Zone Module is used to connect conventional 2-wire smoke detectors to the system. Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Module provides a single addressable LED that is controlled by the control panel. Speaker Module provides switching for two audio channels. Addressable LED and key switch that mounts in a single gang box. DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Dimensions 0 01 TOP , DEPTH o DOOR= 16.07 BACKBOX = 15.77" DEPTH =384" 0 0 0 LEFT SIDE RIGHT SIDE BOTTOM Page 4 of 6 001317 Revised: 15-Deo-2017 BT1201 Battery, 12V I2AH (2 Req'd) 186421 BT-180 Battery, 12V I8AH (2 Req'd) - 18643 BT-260 Battery, 12V 26AH (2 Req'd) - 18644 1JFS-1P Series cabinets will not hold I2AH batteries. Janus recommends using I8AH batteries when 12AH are required. nia Spare CPU, JFS-IP60 97604 n/a EOL Resistor/Diode Assembly for Releasing Circuit 18712 n/a EOL Resistor, 5.1K - - 99950 PADIOO-SLCE Analog/Addressable Loop Expansion Module 97652 JFS-ANNI LCD Remote Annunciator 99247 JFS-ANN2 LCD Remote Annunciator 98725 LED-16 16 LED Annunciator 97644 LED-16F 16 LED Annuciator (Flush model) 97645 JFS-PSI000 Remote Intelligent Power Supply 98802 JFS-PSI000E Remote Intelligent Power Supply (room for 6 Expansion Cards) 98728 CA-6500 Class A Expander Module 98730 UD-1 000 Digital Alarm Communicator Transmitter 98729 DRV-50 LED Driver Module 98529 FCB-1000 - Fire Communication Bridge - - - - 98528 FIB-1000 Fiber Interface Bridge 98527 RLY-5 Relay Expander Module 98526 SPG-1 000 Serial Parallel Gateway - 98525 MC-1000 Multi-Connect -- 97651 AE-2 Two Card Expansion Cabinet - 97647 AE-8 Eight Card Expansion Cabinet - 98622 AE-14 Fourteen Card Expansion Cabinet__ 98621 Page 5 of 6 I I I I I I I I I I I I I I I I I I I OS117 Revised 15-Oe-2017 L PADIOO-MIM Minia:ure Input Module 97666 PADIOO-PSSA Single Action Addressable Pull Station 97654 PADIOO-PSDA Dual Action Addressable Pull Station 97655 PADiOO-SlM Single Input Module 97662 - PADI 00-DIM Dual Input Module 9663 PADIOO-TRTI Two Relay Two Input Module 9665 PADI 00-NAC Notification Appliance Circuit 97659 PADIOO-ZM Zone Module 97660 PADIOO-IM Isolater Module 97658 [PAD100-RM Relay Module 97661 PADIOO-LED LED Module 97656 PADIOO-SM Speaker Module 97653 PADIOO-LEDK LED and Key Switch 97657 PADIOO-DRTS DUCTR Remote Test Switch 97678 PADIOO-OROI One Relay One Input Module 97664 .1IILoopTIDevices PADIOO-PD Analog Photoelectric Smoke Detector 97670 PADIOO-PHD Com bnation Analog Photoelectric Smoke/Heat Detector 97669 PADIOO-HD Analog Fixed Temperature Heat Detector 97668 PADIOO-DUCTR Addressable Duct Smoke Detector with Form C Relay 97677 PADIOO-DUCT Addressable Duct Smoke Detector 97676 PADI00-6DB 6' Analog Smoke Detector Base 97671 PADI00-4D8 4' Analog Smoke Detector Base 97672 PADIOO-IB Addressable Isolator Base 97673 PADI 00-RB Addressable Relay Base 97675 PADIOO-SB Addressable Sounder Base 97674 PADI 00-CD Addressable CO Gas Detector 97667 Note: Approval.fiListings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Evety attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. *'21111 JAJ4US' FIRE SYSTMtS* 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-ma I: info@janusfiresystems.com wwwjanusfiresystems.com Page 60f6 Ds1345 Reused 15.Derv2017 PHOTOELECTRIC SMOKE SENSOR 7 TI LISTED PIN See Chart Description Features Low profile, less than 2 inches with the base Wide selectable sensitivity range of 1.0 to 31%/foot Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting, no programming tool required LED alarm indicator Specifications Operating Voltage: 24 VDC Alarm indicator: 1 LED Alarm set-point range: 1.0 tD 37 %Ift (3.6-12 %!m) Installation temperature range: 32 to 120DF (0 to 49°C) Operating relative humidity range: 0% to 93110' (Non-condensing) Start-up time: Max. 1 sec. Maximum number of addresses per loop: 127 Maximum number of lighted indicators in alarm per loop: 30 Color: Eggshell White Weight (no base): big (3.56 oz) Height (no base): 1.35 in (34 mm) Diameter (no base): 3.93 irches (100 mm) The Photoelectric Smoke Sensor is a listed Analog Addressable smDke sensor corn Datible with fire alarm control panels that utilize the Potter Addressable Device (PAD'I protocol. The PAD1 00-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD1 00-PD has a sensitivity range of 1.0 to 3.7 % per foot and is UL. The PAD1 30-PD features drift compensation and has built in dirty detector warning as well as. The PAD1 00-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than lye (5) seconds, well un- der the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD100- 3D is addressed using DIP switches in the rear of the sensor and can be easily programmed in the leld without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to preven: potential dam- age to SLC or device. Verify the following: Power to the device is removed Field wiring is correctly installed. Field wiring has no open or short circuits. Air Velocity Ratings The PAD1 00-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneoLsly. If the system already has 30 LEDs on, the PAD100-PD will operate even though the LED may not illuminate. © 2017 Janus Fee Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademuk of Janus Fire Systems. 0S1345 Revised: 15-Oeo.2017 Operation The PAD 100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD1 00-PD with the PAD100-4D8 or PAD100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD1 00-PD can be programmed to provide a maintenance alert prior to reaching the dirty sen- sor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE: As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA72 for specific information regarding detector spacing, placement and special applications. [AU1UU-U PAD100-6DB iinotoellectriC Smoke sensor 6" Addressable Detector Base 97670 97671 PADI004DB 4" Addressable Detector Base 97672 PADI 00-lB 6" base with an isolator module included 97673 6" base with one Form-C relay contact. 2A 3OVDC, O.5A PADI GO-RB I25VAC 97675 6" base with sounder module included. Sound pattern is PADI 00-SB provided from external source 97674 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. aiPT'R'ESYSTEM'S° 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: infocjanusfiresystems.com www.janusfiresystems.com Page 2 of 2 g. @ LISTED PIN See Chart Description 051339 Revised, 15-Dee-2017 DA VM'L2J7~100~4DB/ 4"/6" ADDRESSABLE DETECTOR BAS ;A Features Terminals Marked with Polarity to assist with installation Duplicate terminals for in and out SLC wiring Terminals accept 22 to 12 AWG wire sizes Installs on single gang, double gang, octagon or 4" square box Locking tab prevents unauthorized detector removal Specifications Mounting Options: Single gang, double gang, octagon, and 4" square box Terminals: Screw-Clamp Type Wire Gauge: 22 to 12 AWG Diameter. 6.3 in (166 mm) Height 0.72 in (18 mm) Shipping Weight: 87g (3.07 oz) Material: Durable Plastic The PAD1 00-6DB and PAD1 004D13 are low-profile, surface mount bases used with Potter's address- able detectors. The base uses screwclamp terminals that accept wire ranging from 22 to 14 AWG. When installed on recessed electrical boxes the PAD100-6DB is wide enough to completely cover the back box and the immediate surrounding area. The base is equipped with a lockinç tab to deter unauthorized removal of the attached detector. Application The PAD1 00-6DB and PAD1 00-4DB detector bases are used to install addressable smoke and heat detectors. The PAD1 00-6DB will mount on a single gang, double gang, octagon or 4" square electri- cal box. Locking Feature The PAD100-6DB and PAD100-4DB include a locking feature that prevents removal of the detector without using a tool. 1. To eliminata this feature, break off the locking tab (refer to figure below), and then install the detec- tor. Break off tab (gray area) in image to disable locking feature. ® 2017 Janus Fire Sys-.ems. All rights reserved (512017) Janus Fire Systems® is a rgiatered trademark of Janus Fire Systems. C51339 Re'tsed: 15-Dec-2,:17 2. To remove the detector from the base when the locking feature has been enabled, insert a small screw driver into the slot on the base to push the plastic tab while simultaneously turning the detector head counter-clockwise. Insert small screwdr into slot to remove detector from base. Wiring Diagram To FAC Loop ( PADI00-4DB 4" Addressable Detector Base 97672 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. JA FrR,E S'Y:M.s 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com Page 2 of 2 DSt337 Revised: 15-Dec.2017 AI[tsI1IAUIl[s]i1IJI 'r - -jg ML PAD 1OO-IM SLC I&1. - 11 H LISTED P/N 97666 Description Features One Class B contact 'ronitoring input Small size allows mounting in most electrical boxes SLC Class A. Class X & Class B 6" Pigtail wiring connections Specifications Operating Voltage 24.OV Max SLC Standby Curie it: 200pA Max SLC Alarm Current: 200pA IDC Input Circuit Wiring: Class B Max Wring Resistance of IDC: 100 0 Max Wring Capacitance of IDC: 1 p EOL Resistor: 5.1K 0 Operating Temperature Raige: 32 to 120°F (0 tc 49°C) Operating Humidity Range: 0 to 93% (non-condeising) Max no. of Module Per Locp 127 units Dimensions: 1.75" x 1.36" x 0.43" 44.5 mm x 34.5 mmxli mm) Mounting Options: 2-1/2" (64mm) deep single-gang box Shipping Weight 0.3 lbs The PAD1 00-MIM is used to monitor the status of an initiating device(s) that contain a normally open set of dry contacts. The module is enclosed in a plastic case to protect against inadver.ent shorts and ground faults. The case can be mounted using a single screw. The PAD100-MIM has a status indicator LED to indicate communication and alarm conditon. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The micro input module (PAD100-MIM) is compatible with JFS-lP series addressable fire alarm con- trol panels. Generally the PAD100-MIM is used to monitor oull stations and other devices where the module is installed in an electrical box or enclosure behind the device being monitored. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the front of the PAD1 00-MIM. Before connecting a device to the SLC loop, take the follow- ing precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. © 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire System® is a registered trademark of Janus Fire Systems 001337 Revsed: 1wDo'2017 Wiring PADIOO-MIM Micro Input Module 97666 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice, OJMftTS PuIRE S YStEMS 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: infojanusfiresystems.com www.janusflresystems.com Page 2 of 2 001331 Revved 15-Dec,2017 RELAY MODULE LISTED PIN 97661 Description Features One (1) Form C relay cortact SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when moLnted in box All wiring terminals accept 22 tc 12 AWG Specifications Operating VoIage: 24.OV Max SLC Standbj Current: 240)JA Max SLC Alarm Current: 240lJA Relay Contacts: 2A @30VDC, 0.5A @ 125VAC Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humid ty Range: 0 t3 93% (ion-condensing) Max no. of Module Per Loop: 127 units Dimensions: 4.17"x 4.17" x 1.14(106mm x 106 mm 29 nm) Mounting Opt ons: Standard 4' Square or Dcuble Gang Box Shipping Weight: 0.6 lbs The PAD100-RM uses one (1) SLC loop address to provide one (1) Form C relay contact. The module mounts on either a 4" square or double gang box. The PAD 100-RM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PAD 1 00-RM is compatible with J ES-I P series addressable fire alarm controli panels. The PAD1 00- RM is an interface module providing one (1) Form C relay contact. Setting the Address Each addressable SLC device must be assigned an address. Tie address is set using the DIP switch located on the PAD100-RM. The PAD100-RM uses a single device address to identify relay contacts. Before connecting a device to the SLC loop, take the following precautions to prevent potential dam- age to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. @2017 Janus Fire Systems. All rights reserved (5/2)17) Janus Fire System 30 is a registered trademark of isnus Fire Systems. 051331 Revised: 15-Oo,201 Installation Wiring PAD 100-RM Relay Circuit NOTE: It is possible that the internal relay in the PADIOO-RM may be shipped in the non-normal / activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. FROM FACPOR PREVIOUS MODULE TO NEXT MODULE 1) FORM C CONTACTS -- PADIOO-RM Relay Module 97661 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. JNUS: 'Fi RE SYSTEMS 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com Page 2 of 2 ADIOOPSSA/PSDA ADDRESSABLE PULL STATION PIN See Chart Description Features Single or Dual Action versions Durable die-cast construction Reset key matches the fire alarm control panels Compatible with IP Se1es panels SLC Class A, Class X & ClEss B Specifications Operating Voltage 24.OV Max SLC Standby Current: 200pA Max SLC Alarm Current: 203pA Operating Temperature Rarge: 32 to 120°F (0 to 49°C) Indoor Only Operating Humidity Range: .0 to 3% (non-ondeising) Dimensions: 4.75'x 3.25" x 1.75" ('21 mm x 83mm '(45 mm) Mounting Options: Single gang box Shipping Weight: Single Action - 1.22 lbs Double Acion - 1.46 lbs 061338 Resed: 14-Aug-2019 The PAD1 00-PSSA (Single Action) is activated by simply pulling the white 'T" bar handle down. The PAD100-PSDA (Dual Action) is activated by lifting the front cover and then pulling the wh te 'T" bar handle down. Once activated, the "1" bar cannot be reset without opening the front cover. Opening the front cover will also activate the pull station. To reset the PAD1 Co-PS Series, use the supplied WS-93 key (P/N 99622) to unlock and open the front cover. Once the cover is open, push the "1" bar back into the normal position and re-secure the front cover. Application The PAD I 00-PSSNPSDA is compatible with JFS-IP series addressable fire alarm control panels. It is a non-coded addressable pull station available in either a single or dLaI ac-ion model and nstalls on a single gang box or surface mounts using the P32-BB back box. Setting the Address The PAD1 00-PS Series uses one SLC address assigned to the device. The address is set using the DIP switch located on the back of the PAD1 00-PS device. PADI OO-PSSA PADI OO-PSDA © 2017 Janus Fire Sysems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire System. Wiring FROM FACPOR PREVIOUS DEVICE TO NEXT DEVICE WIRED CONTACTS PADIOO-PSSA Addressable Pull Station, Single Action 97654 PADIOO-PSDA Addressable Pull Station, Dual Action 97655 Box, Surface mount, keg, unaoor WS-93 Key, Spare, JFS Series 99622 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contractor sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are Subject to change without notice. SYTEM'S° 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com Page 2 of 2 I I I I I I I I I I I I I I I I I I I DS138 Revised: 14-Aug-2019 STEM SHOWN IN :ET POSITION- PULL UP ON STEM TO MANUALLY OPERATED OPERATE SWITCH WIRING SCREW TERMINALS OPETEESCH1 L-8CCVERSCRENS 39,DJ V.ACYIOAU-25OV.AC PT.NO.L&5,8 "- TO RESET PUH STEM TO SET POSITION u I 15ArP '25 VAC 10 AMP 250 VAC 3/4HPI.2-3PH125-48OVAC 1/2" SUPPLY PIPE WITH UNION FRONT VIEW OX 3 EACH SIDE /2" CCNDUIT NOCKDUTS T FEMALE, ECT TO SYSTEM PIPING SIDE SECTION OPERATED SET NC NC NC 1 ID TE 0 : G) NO NO PRESSURE INLET WIR: N DIAGRAM SWITCH COVE FRONT VIEW COVER REMOVED Kidde ECS Fire Suppression System Component Description Pressure Operated Switch FEATURES For Use with UL Listed, ULC Listed ard FM Approved Systems Kidde Fire Systems Effective: Jane 2014 K-90-5180 See Kidde® Manual 06-236225-001 for USCG Approval PIN: 81-486536-000 NOTES: The Switch may be mounted in any rosition; how- • Contact Ratings (3 PD): ever, the preferred installation is upriIt, as showr. - 15 Amp @125 V3c Any load connection to the switch mus: not exceed - 10 Amp @250 Vac the switch rating, and shall utilize a suitable protec- - 3/4 HP @ 250 Vac tion device (i.e, circuit breaker, fuse',. - 1, 2 or 3 Phase 1 I I L I [1 I I n] I PUSHBUTTON CONFIGURATION (NORMALLY OPEN IN NORMAL POSITION) 1. LISTINGS: -UL, FM - 1/ in 2. TECHNICAL DATA: [44.5 mm] -APPLICATION: MAS-1 MOMENTARY ABORT STATION PROVIDES A PUSHBUTTON ACTIVATED SYSTEM ABORT CAPABILITIES. ABORT FOR THE MAS-1 IS ACHIEVED WITH A YELLOW DEADN1AN STYLE MUSHROOM HEAD PUSHBUTTON. 41B0R1 -TEMPERATURE RANGE (INDOOR): 32°F TO 120°F [0°C TO - 48.89°C], 90% RELATIVE HUMIDITY @ 100°F [37.8°C] -CONTACT RATING: 4 AMP @ 30 VAC, 0.5 AMP © 30 VDC TO ABORT. PUSH AND HOLD -TERMINAL CONNECTIONS: 2 X 16 AWG, 1 X 14 AWG -WEIGHT: 1.2 LB [0.544 KG] 55/4 in 3¼in 3. MATERIAL: [133.4 1 [82.6 mm] -BODY: STAINLESS STEEL FACE PLATE -FINISH: BLACK LETTERING; PUSHBUTTON IS YELLOW 4. NOTES: -THE MAS-1 ABORT FUNCTION IS INITIATED BY PRESSING AND JAiTN1JS HOLDING THE YELLOW PUSHBUTTON - I -THE FACEPLATE MOUNTS TO A STANDARD UL LISTED 2-GANG SWITCH BOX. [5.9 mm] [134.9 mm] THE SELLER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, EXCEPT AS EXPRESSLY STATED IN THE SELLER'S SALES CONTRACT OR SALES ACKNOWLEDGMENT FORM. EVERY ATTEMPT IS MADE TO KEEP OUR PRODUCT INFORMATION UP-TO-DATE AND ACCURATE. ALL SPECIFIC APPLICATIONS CANNOT BE COVERED, NOR CAN ALL REQUIREMENTS BE ANTICIPATED. ALL SPECIFICATIONS ARE SIJBJECr 10 CHANGE WITHOUT NOTICE. DETAIL SHEET NO, STOCK NO. REV *)AN[ U S DS-1203 18847 1 DESCRIPTION F I RE S YSTEMS" STATION, ABORT, MOMENTARY, MAS-1, INDOOR I I I I I I I I Key Maintenance Switch Kidde Fire Systems A UTC Fire & Security company Effective: May 2009 K-76-606 FEATURES cFMus Approved to ANSI/UL 864, 9th edition, CANADAIULC-5527 and ANSI/N FPA 72 Stainless Steel Plate Status LED Indicators Surface or Flush Mount Installations DESCRIPTION This Key Maintenance Switch is a key-switch tiat discon- nects actuation circuits in the system to prevent acciden- tal discharge of fire suppression systems during maintenance operations. The Key Maintenance Switch provides a means to short the Metron Actuator circuit leads for safe disconnection of conventional and addressable control units. Refer to the installation wiring diagram for detailed wiring connec- tions. Two LEDS indicate "SYSTEM ARMED or 'SYSTEM INACTIVE" when the key is inserted and turned. The key can only be removed in the armed posit on. Key Maintenance Switch mou its to a 4-inch backbox and operates on 24 Vdc. Designed for mounting on the wall with a tack box. Key Maintenance Switch can be installed in either surface mount or flush mount configurations. Key Maintenance Switch physically disconnects the release circuit wiring in addition to the trcjble open signal, the switch provides a means to gene-ate a supervisory condition. ORDERING INFORMATION Part Number Description I 76-600000-200 Key Maintenance Switch 06-236881-001 Backbox Safely Disconnects Actuation Circuits by Shorting Metron Actuators Key Operated (Nonremovable When Operated) Four-Pole Double-Throw Switch Meets the Requirements of NZPA72 (2007 edition) ELECTRICAL Switch: 4PDT Key Switch - ore set ol contacts control indicators on the faceplate. - Three remaining contacts are available for application wiring. Device Current: 10 A @ 253 Vac 15A@ 125 Vac 15 A @ up to 30 Vdc Electrical Life: 50,000 cycles - maintained 25,000 cycles - -momentary ENVIRONMENTAL Operating Temperature 32 to 120°F (0 to 49°C) Range: MECHANICAL Mechanical Life: 100,000 cycles Switch Plate Stainless Steel Construction: This literature is provided for informational purposes only. KIDLE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular appli:a:iol. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-76-606 Rev AB © 2009 Kidde-Fe,wal Inc. Printed in USA Kide Fire Sjstems A LTC F re & Security Company 40C Mair Street Ashland, MA 01721 Ph: 508.381.2000 Fax: 50888 .8920 www.kiddefiresysterns.com I SYSTEM $ SENSOR® Indoor Selectable, Output Horns I Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification I products are rich with features guaranteed to cut installation times and maximize profits with lower I current draw and modern aesthetics. Features I I Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in cesign with minimal intrusion into the back box Tamper-resistant construction Automat:c selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device irstallation Electricaiy compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Strobes and Horn Strobes listed for wall mounting only Horns listed for wall or ceiling use Agency Listings SIGNAIJIG LISTED APPROVED S5512 FM approved except 7125-16530504 S4011 for ALERT models 1135-16530503 3057383, 3057072 The System Sensor L.Series ofiers the most versatile and easy-to-use line of horns, st:obes, and horn strobes in the industry with lower current draws and mode-r. aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor [-Series can meet virtually any applicaticn requirement. The [-Series ling of wall-mount horrs, strobes, and horn strobes include a variety of features that increase their application verssfili:y while simplifying installa:ion. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof woile virtually aliminahrg costly and time-consunvng ground faults. To further simplify inslafation and proect devices from construction damage, the [-Series uttlizes a universal mounting plate for all models with an onboard shcrting spring, so installers can test wirirg continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selec:ion of 12- or 24-volt coeration, and a rotary sw tch for horn tones with two volune selections. AVDS865.05 • 2/22/2018 Pale L-Series Specifications 7. - '-1 General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-in:h back box, 4 x 4 x 11/2-inct back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mouit to a single-gang 2 x 4 x 17/8-inch back cox. A universal mounting plate shall be used for mounting ceiling and wall products for all standard model; and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall term nate at the universal mounting qlats. Also, L-Series products, when used with the Sync'Circuir Module accessory, shall be powered from a non-coded notificeton appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Mocule, 12-volt-rated notif cation appliance circuit outputs shall operate between 8.5 and 17.5 volts: 2-volt-rated notification appliance circuit outputs shall operate between 16.5 ard 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered rower supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for tim protective se"vice. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements tor visible signaling appliances, flashing at 1 Hz over tie strobe's entire operating voltage range. The strobelight shall; consist of xenor flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and U_ 464 and shall be approved 'o fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disaoilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe ligh[ shall consist of a xenon flash tube and associated lens/reflector system. The horn shalt have two audibility options and ai option to switch between a temporal three pattern and a non-temporal continuous) pattern. These options are set by a multiple position switch. The I-Orn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 arid shall be approved for lire protective service. The module shall synchronize Strobes at 1 Hz aid horns at temporal three. Also, while operatirg the strobes, tie module shall sileice the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The rroduin shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shalt synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate o a coded power supply. /. ,. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash pe second Nominal Voltage Regulatec 12 DC or regulated 24 DC!FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V ncminsl) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 155 to 33 V (24 V nominal) Input Terminal Wire Gauge 1210 18 /1WG Wall-Mount Dimensions (including lens) 5.6-L x 4 7"W x 1.91" D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (inclucng lens) 5.26" Lx 3.46" W x 1.91" 0 (133 mm Lx 88 mm W 49 mm D) Horn Dimensions 5.6"L x 4.7"W ° 1.25"D (143 mm Lx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" 0 (133 mm Lx 88 mm Wx 32 mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply ard panel outputs Strobe products will operate at 12 V nomnnal only to' 15 cd and 30 cd. AVD8865.05 • 2/22/2018 . Page 2 I I UL Current Draw Data A Max. Horn Current Draw (mA RMS)' J 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hah 42 43 54 UL Max. Current Draw (mA DC Input RMS), Wall Horn 8-17.5 Volts 15cd Strobe, 30cd Candela Range 16-33 Volts 15cd (15-185 30cd cd) 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temp:ortal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1KNon-emporalHigh 99 162 69 90 135 157 175 208 261 3.1K Non-emp0ra1 Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1KTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-emporal High 104 131 177 204 230 264 326 3.1K Non-emp0ra1 Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Ho'rn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3,1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. It the NAC voltage is held constant, the horn output remains constantly on. AVOS865-05 21221201 S • Page 3 I I I LI I I I I [H I U I Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 L-Series Dimensions 1.9.V _ 411.6 mm 88 MM t25 3.57" 1.55 88 MM 11.I 32 rrn (9.1 cm) (3.9 cm) 133.9 mm a2mm 13m .'3. CM) 3.9 A0548-00 AO&'.- A0557.00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL ie— 4.70" (11.94 cm) t.- .4.55CM) W8 MM) 5.67 (14.4cm) Strobe Horn Strobe AOwC-00 1.25 U2 "' - 8S 32mm 12.24 cm) (4.69 cm) r;1 o 0 LP :acm AO55a-01 A05—CO A0554-01 Surface Mo unt Back Box SBBRLJSBBWL Horn L-Series Ordering Information Em- Wall Horn Strobes Horns P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horr, 'Ishite P2GRL 2-Wire, Compact Horn St one, Red HGRL* Compact Horn, Red P2GWL 2-Wire, Comp 2 fits act Horn Strobe, White HGWL Compact Horn, White P2RL-F 2-Wire, Horn Strobe, Red. Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 UnvcrstI 'fiat Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red. FUEGO TR-2W Unvsrsal Wall Trim Riiig White P2W) -SP 2-0/jr4, Ham StrrchC Whit- El IE1 SBBRL Wall Sjrface Mount Rack Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Sjrface Mount Rack Box, White i-'4VVL 471vire, r-iorn bircoc, senile SBBGRL Corract Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact \A() Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All-P models have a plain tousig (no 'FIRE" marking on cover), All -SP models have "FUEGO" marking jn cover. All -ALERT models have "AERT" markiig on cover. *Horn_only models are I stec for wall cr ceiling use. T"\SYSTEM S525 Ohio Avenue • St. charles, IL 60174 Phcne ' BOO -SENSOR2 • 02018 System sector. Fax' 630-371-6495 PrcOrctepeciticacor's subject to change w,tlout canoe. visit staternse000t.com - ca current prodr.ct -atormatw. including the Ia.est version at bbs data sheet. E www.systemsensor.com AvcS8135-05 • 2/2212018 SYSTEM SENSOR® Audible Visible Accessories System Sensor L-Series offers a wide range of Audible Visible (4V) accessories to enable you to meet a variety of application requirements. Features MP120KL Mounting Plate Designed for both indoor and outdoor use Plug-in design eliminates ground faults Power supply that converts 120 VAC to nominal 24 V FWR Compatible with all two-wire L-Series devices Color Lens Attachments Easily turns any device into a strobe for ECS/MNS events: severe weather, toxic gases, sprinkler activation and more Outdoor rated from —35°F to 151°F Wall- or ceiling-mount lenses available UL 1638 listed Bezel Kits Easily turn a Fire or Plain device into a device to meet ECSIMNS requirements Bezel ki:s available for strobes, horns, chimes, horn strobes, chime s:robes and speaker strobes Bezels options with FIRE, ALERT, EVAC, AGENT, PLAIN, FUEGO, FOGO printing For use with L-Series devices only Operating temperature -40°F to 151°F Agency Listings & <~> 0 LISTED APPROVED S5552 FM approved 7125-16530504 S4071 Sync nodules and MPI20KL 1135-16530503 S4008 3057383, 3057072. 3057493 Does not include Color lenses. The MP120KL Mounting Plate IS designed to use 120 VAC to power SpectrAlert Advance horns, strobes, horn strobes, chimes, and chime strobes. Color Lens Attachments izstall easily on any L-Serles strobe devices to provide distinctive visual signaling. Bezel Kits enable installers to easily turn any L-Series Fire Cr Plain device nto a device that meets EN/MNS requirements. Bezel kits are ave.lable for all varieties and tootprints of L-Series products and come :r: FIRE, ALERT, EVAC, AGEINT, FUEGO, FOGO, and Flain options making customizaton easy, Universal Trim Rings for w5i1 erse ceiling mount devices allow for additional space within the .ack5ax, L-Series Surface Mount Back Boxes are the best solution in Iocatics where you have a -:ard surface to mount to. The Sync-Circuit Module svnchrnizes L-Series strobes at Hz and horns and chimes at tempo-al 3 :.'er a single pair of wires. Patented module technology also aIlcs the silencing of horns or chines on horn s:rjbe and chime stroce models over a pair of wires. See the Sync.Circuit Datasheet for nore tcformation, Specifications 120 VAC mounting plate model MF12OKL shall be hsted to UL 464 for fire protective signaling systems. The mounting plate shall power a two- wire L-Senes horn, strobe, horn strobe, chime or chime strobe from a 120 VAC supply converted to nominal 24 V FWR. For indoor applications, the mounting plate shall be installed in a 4x4x21;8 -inch junction box. - -- -i-i MP120KL may be used with any of the following products at at horn and strobe settings; F2AL, P2WL, F2RL-F, F2WL-P, F2AL-SP, F2WL-SF, FC2AL, FC2WL, SAL, SWL, SAL-F, SWL-P, SAL-SF, SVVL-ClA-ALEAT, SWL-ALERT, SCAL, SCWL, SCWL-CLA-ALERT, HAL, HWL, CHAL, CHWL, CHSAL, CHSWL, CHSCAL, CHSCWL. I'fl!1 Ler TThr 1ITIIn '' . O - Standard Operating Temperature —40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Nominal Voltage Regulated 120 VAC Operating Voltage Range 96-132 VAC Current Draw From AC Line 150 mA max. 1115-T717 M_:TM_ 171 " The System Sensor L-Series bezels are for installation with strobes, horns, chimes, horn strobes, chime strobes, and speaker strobes. Bezels are offered in red and white for both wall and ceiling devices. Available in FIRE, ALERT, EVAC, AGENT, Plain (no marking), FUEGO, and FOGO. Operating temperature shall be -40°F to 151°F L i Specifications LColoredILens Ti1rT The System Sensor L-Series colored lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with plain (no FIRE' print) System Sensor strobe devices or in conjunction with a non-fire printed bezel. The lens shall mount to any wall- or ceiling-mount strobes and shall be rated from —35°F to 151°F I Colored lens attachments may be used with the following System Sensor [-Series plain (non-FIRE-printed) strobe models: P2RL-P, P2WL- SRL-F SWL-P, SPSRL-P, SPSWL-P, SPSCWL-P, or any device used with a non-FIRE printed bezel. Colored Lens Installation Installation to Wall-Mount Strobe Installation to Ceiling-Mount Strobe Ordering Information Surface Mount Back Box Colored Lenses SBBRL Red, wall-mount, compatible with standard LENS-132 Wall-mount, blue horns, strobes, horn strobes, chftres and chime LENS-R2 Wall-mount, red I strobes LENS-G2 Wall-mount, green SBBWL White, wall-mount, compatible with standard horns, strobes, horn strobes, chimes and chime LENS-A2 Wall-mount, amber strobes LENS-BC2 Ceiling-mount, blue SBBSPRL Red, wall-mount, compatible with speakers and L.NS-RC2 Ceiling-mount, red speaker strobes LENS-GC2 Ceiling-mount, green SBBSFWL White, wall-mount, compatible with speakers LENS-AC2 Ceiling-mount, amber and speaker strobes SBBCRL Red, ceiling-mount compatible with horns, Retrofit Plates strobe, horn strobes, chimes, chime strobes, (--or use with horn strobe & speaker strobe devices) speakers and speaker strobes RFPW 9.5' x 7" white SBBCWL White, ceiling-mount, compatible with horns, RFP 9.5" X 7" red strobe, horn strobes, chimes, chime strobes, Mounting Plate speakers and speaker strobes N'IP120KL 120 VAC Adapter Mounting Plate SBBGRL Red, wall-mount, compatible with compact horns, strobes, horn strobes Sync Modules SBBGWL White, wall-mount, compatible with MDL3W White, 12/24 volt Sync-Circuit module compact horns, strobes, horn strobes MDL3R Red, 12/24 volt Sync-Circuit module Bezels* Trim Rings BZR Wall Red Bezel Kit TR-2 Universal wall trim ring, red, 6.3" x 8.2" BZW Wall White Bezel Kit TRC-2 Universal ceiling trim ring, red, diameter 8.5' BZGR Compact Wall Red Bezel Kit TR-2W Universal wall trim ring, white, 6.3" x 8.2" BZGW Compact Wall White Bezel Kit TRC-2W Universal ceiling trim ring, white, diameter 8.5" BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceiling White Bezel Kit BZSPR Speaker Wall Red Bezel Kit BZSPW Speaker Wall White Bezel Kit BZSPRC Speaker Ceiling Red Bezel Kit BZSPWC Speaker Ceiling White Bezel Kit *Each bezel pack ships in a package of 5. For desired bezel option add -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -SP (FUEGO), -PG (FOGO) for desired printing. 3825 Ohio Avenue • St. Charles, IL 60174 52017 System Sensor Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications Subject to chanpe rn,tflsut notice. Visit systernseasor.cunr .EItt.s'oi or current product niormacon, including the latest version at this data street. www.systemsensor.ccm Al2S87001 • 03.17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-2007:0500 Page 1 of 1 I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: JANUS FIRE SYSTEMS1102 Rupcich D, Crown Point, IN 46307 Contact: Dennis Ley (219) 663-1600 Fax (219) 663-4562 I Email: dley@janusfiresystems.com DESIGN: Models JFS-IP60, JFS-1P127, and JFS-IP4000 fire alarm control units. Automatic, Manual, waterliow and sprinkler supervisory type device and local, auxiliary, releasing, remote station I (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components (CSFM Listing 7305-0328:0200): PAD100-DIM Dual Input Module I PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module I PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module I PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module I PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *SLCE..127 Loop Expander I RATING: 24 VDC lNSTALLAlON: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. XLF: 7165-0328:0500 01-14-2019 dcc r: This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0328:0504 . Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 - Email: billw©pottersignal.com DESIGN: Models PAD100-PD, PAD100-DD and PAD100-PHD photoelectric smoke detector heads. Model PAD 100-PHD has an intergral heat detector. Refer to Listee's data sheet for detailed product description and opeational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Models PAD100-PD and PAD100-PHD are listed as photoelectric smoke detector heads for use with listee's detector base Models PAD100-4DB, PAD 100-6DB, PAD100-B, PAD1 00-SB (CSFM#7300-0328:502) and Model PAD1 00-I B (CSFM#7300-0328:501). Model PAD 100-DD is listed as a photoelectric smoke detector head for use with Mocel PAD 100-DUCT (CSFM#3248-0328:0505). Refer to listee's Installation Instruct on Manual for details. 06-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of a.-ly claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installa on instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Divisior CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0328:0502 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Models PAD 100-4DB, PAD 100-6DB, PAD 100-RB and PAD iOO-SB detector bases. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a addressable isolator base for use with separately listed compatible fire alarm control units and listee's separately listed Models PAD-100-PD and PAD-100-PHD (CSFM#7272-0328:0504), PAD-100-HD (CSFM#7270-0328:0503) and PAD-10G-CD (CSFM#5278-0328:0506) detector heads. Refer to listee's Installation Instruction Manual for details. 06-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-2007:0101 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: JANUS FIRE 5YSTEMS1102 Rupcich D, Crown Point, IN 46307 Contact: Dennis Ley (219) 663-1600 Fax (219) 663-4562 Email: dleyjanusfiresystems.com DESIGN: Models MRS-1 Main/Reserve/Transfer, MAS-i Momentary Abort, LOS-1 Keyed Lock-Out, ARS-i Abort./Releasing, and MMS-i Momentary Releasing switch assembly stations. Model MRS-1 uses a DPDT toggle switch to transfer suppression system releasing circuits from a main supply to a reserve supply. MAS-i uses a SPST pushbutton switch to provide pushbutton activated system abort capabilities. LOS-1 uses key activated DPDT switch to disconnect and electrically lock-out the releasing circuit of a fire suppression system. ARS-1 uses both momentary SPST pushbutton switch and a momentary DPST toggle switch to combine the function of a Manual Release Station and Abort Station into a single unit. MMS-i uses a momentary DPST toggle switch to provide a non-maintained manually initiated release of fire suppression agent. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: MRS-1 Contact Rating (DPDT) -250 VAC, 10 A MMS-i Contact Rating (DPDT) - 250 VAC, 10 A MAS-i Contact Rating (SPST) - 415 VAC, 4 A / 110 VDC, 0.5 A LOS-1 Contact Rating (DPDT) - 415 VAC, 4 A / 110 VDC, 0.5 A ARS-i Contact Rating (SPST) -415 VAC, 4 A / 110 VDC, 0.5 A .ARS-i Contact Rating (DPDT) - 250 VAC, 10 A INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as miscellaneous control accesssories for use with listee 's separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. (7-27-1) fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This Iisticg is not an endorsement or recommendation of the item listed. This listing should not be used to verify. correct operationaL requirements or installation criteria. Refer to listee's data sheet, installation instructions and.'cr other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE IA OEPAR I I'CAL FIRE SINCE 1865 I LISTING No. 7150-0328:0201 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: bilIwpottersignal.com DESIGN: Models APS-SA, *PAD100..PSSA single action and APS-DA, *PAD100..PSDA dual action addressable pull boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 22-24 VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, rating and UL label. APPROVAL: Listed addressable pull boxes for use with separately listed and compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. *Revision 02-10-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 30174 Thntact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneyweli.com DESIGN: 'System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Nail Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. 'Nail Bezel Parts: 3ZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, 3ZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PC-. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 aid LEN S-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL aid SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational consic&ations. *Rev 04-04-19 gt r This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 33, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date lssjed: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 cf 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4_wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP P2WL-SP, *P4RL and *P4VL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-FG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-3, BZ3R-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZG1-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-EP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP a!d BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-3C2, .INS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W Ceilinglrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision CE._21_2017 dcc This listing is based upon technical data submitted by the applicant. CSFrl Fire Engineering staff has reviewed iie est results and/or other data but does not make an independent verification of any claims. This listing is not n endorsement or recommendation of the item listed. This Iisthg should not be used to verify correct :perational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorizec By: DAVID CASTILLO, Program. Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. I I I I [11 I I I Revision 08-21-2017 dcc rk This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division