Loading...
HomeMy WebLinkAbout5823 NEWTON DR; ; AS160300; Permit11/18/2020 AS160300 Permit Data City of Carlsbad Sprinkler Permit Job Address: 5823 NEWTON DR Permit Type: SPRINK Parcel No: 2120504300 Lot #: 0 Permit No: AS160300 Status: ISSUED Applied 9/15/2016 Approved: 9/21/2016 Reference No.: Issued: 9/21/2016 PC #: Inspector: Project Title: NEWTON DESIGN CENTER ADD (5) PENDANT & (9) ESFR SPRINKLERS TO ACCOMMODATE NEW T.I. IN EXISTING SPRINKLERED BLDG. Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION SUITE B 9510 PATHWAY STREET SANTEE CA 619-562-3010 Owner: LIFE TECHNOLOGIES CORP 5791 VAN ALLEN WAY CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 348 0 348 0 1/1 tqcci Fire Protect Products AS 160300 www.tyco-fire.com 5823 NEWTON DR Model ESFR-25 252 K-factor Pendent Sprinkler Early Suppression, Fast Response General Description TYCO Model ESFR-25 Pendent Sprin- klers are Early Suppression, Fast Response (ESFR) sprinklers having a nominal K-factor of 25.2 (Ref. Figure 1). They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-25 Sprinklers are pri- marily used for ceiling-only sprinkler protection of (but not limited to) the fol- lowing storage applications: most encapsulated or non-encap- sulated common materials including cartoned, unexpanded plastics uncartoned (exposed) expanded plastics in accordance with NFPA 13 and FM Global standards some storage arrangements of rub- ber tires, roll paper, flammable liq- uids, aerosols, and automotive components For more specific criteria, refer to Table A as well as the applicable design standard. The Model ESFR-25 Pendent Sprin- klers provide the system designer with hydraulic and sprinkler place- ment options not presently available to the traditional ESFR sprinklers having nominal K-factors of 14.0 and 16.8. In particular, the Model ESFR-25 Sprin- kler has been designed to operate at substantially lower-end head pres- sures, as compared to ESFR Sprinklers IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 having nominal K-factors of 14.0 and 16.8. This feature offers flexibility when sizing system piping, as well as possi- bly reducing or eliminating the need for a system fire pump. Also, Model ESFR-25 Sprinklers permit use of a maximum deflector-to-ceiling distance of 18 inches (460 mm) versus 14 inches (356 mm). Additionally, a storage arrangement of 40 ft. (12,2 m) with a ceiling height of 45 ft. (13,7 m) does not require in-rack sprinklers as do other ESFR Sprinklers having nominal K-factors of 14.0 and 16.8. The Model ESFR-25 Sprinklers are listed by Underwriters Laboratories (UL) for specific applications with a maximum storage height of 43 ft. (13,1 m) with a maximum ceiling height of 48 ft. (14,6 m) without the requirement for in-rack sprinklers. Refer to the Specific Application Listing (UL) for the design criteria. Applications for the TYCO ESFR Sprin- klers are expanding beyond currently recognized installation standards. For information on research fire tests (e.g., with flammable liquids and aerosols) that may be acceptable to an author- ity having jurisdiction, contact Tyco Fire Protection Products (TFPP) Technical Services. L'L.}tL.1 The Model ESFR-25 Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any authorities having jurisdiction (e.g., FM Global). Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. In all cases, the appropriate NFPA or FM Global installation standard, or other applicable standard, must be referenced to ensure applicability and to obtain complete installation guide- JULY 2016 lines. The general guidelines in this data sheet are not intended to provide complete installation criteria. Sprinkler Identification Number (SIN) TY9226 TY9226 is a re-designation for Central SIN 9226, Gem SIN G8441, and Star SIN S8010. Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved NYC Approved under MEA 356-01-E LPCB Certified (Cert. Nos. 094b and 0071) CE Certified (Certificate of Conformity 1725-CPD-HO010) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connections 1 Inch NPT or ISO 7-R 1 Discharge Coefficient K=25.2 gpm/psi½ (362,9 Ipm/bar½) Temperature Ratings 165°F (74°C) and 212°F (100°C) Finish Natural Brass TFP3I2 TFP3I2 Page 2 of 4 7 - 1"NPT Components: 8 1-13/16" 9/16 (46,0 mm) 1 - Frame (14,3 mm) 2 - Deflector 9 NOMINAL 3 - Compression MAKE-IN Screw 4 -Hook 6 5 - Strut 3-13/16" 6 - Link Assembly (96,8 mm) ________________ THERMAL 7 - Button 5 SENSING 8 - Sealing ELEMENT Assembly 9 - Ejection Spring WRENCH FLATS 3 / 2 TEMPERATURE RATING 2" (50,8 mm) - FIGURE 1 MODEL ESFR-25 PENDENT SPRINKLER, 25.2K EARLY SUPPRESSION, FAST RESPONSE Storage Type NFPA FM Global Open Frame (i.e., no solid shelves) Refer to NFPA 13 Refer to FM Global Single, Double, Multiple-Row, or Portable Rack Storage of Chapters 16 and 17 2-0 and 8-9 Class l-IV and Group A or B Plastics Solid Pile or Palletized Storage of Refer to NFPA 13 Refer to FM Global Class l-IV and Group A or B Plastics Chapters 14 and 15 2-0 and 8-9 Refer to NFPA 13 Refer to FM Global Idle Pallet Storage Chapter 12 2-0, 8-9, and 8-24 Refer to NFPA 13 Refer to FM Global Rubber Tire Storage Chapter 18 2-0 and 8-3 Roll Paper Storage Refer to NFPA 13 Refer to FM Global 8-21 (Refer to the Standard) Chapter 19 Flammable/Ignitable Liquid Storage Refer to NFPA 30 Refer to FM Global 7-29 (Refer to the Standard) Aerosol Storage Refer to NFPA 30B Refer to FM Global 7-31 (Refer to the Standard) Automotive Components in Portable Racks Refer to NFPA 13 N/A (Control mode only; refer to the Standard) Chapter 20 N/A- Not Applicable TABLE A MODEL ESFR-25 PENDENT SPRINKLER COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW TFP3I2 Page 3 of 4 Physical Characteristics Frame .............................Brass Deflector ..........................Bronze Compression Screw ..........Stainless Steel Hook ............................MONEL Strut ............................. MON EL Link Assembly................Solder, Nickel Button .............................Brass Sealing Assembly. Beryllium Nickel w/TEFLON Ejection Spring ..................INCONEL Operation The fusible link assembly is com- prised of two link halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, activating the sprinkler and flowing water. Design Criteria The following general guidelines pro- vided for the TYCO Model ESFR-25 Pendent Sprinklers can be used for a quick reference. The National Fire Protection Associa- tion (NFPA) and FM Global (FM Approv- als) provide installation standards that must be used to properly design an automatic sprinkler system utilizing Early Suppression, Fast Response (ESFR) Sprinklers. The guidelines pro- vided by NFPA and FM Global may differ. Consequently, the appropri- ate standard must be used for a given installation. In all cases, the appropriate NFPA or FM Global installation standard must be referenced to ensure applicabil- ity and to obtain complete installation guidelines. The following general guidelines are not intended to provide complete installa- tion criteria. In addition to this technical data sheet, the following data sheets describe other TYCO ESFR Sprinklers: TFP315 Model ESFR-17 (TY7226) K=16.8 Pendent Sprinkler TFP3I6 Model ESFR-17 (TY7126) K=16.8 Upright Sprinkler TFP317 Model ESFR-17 (TY7223) K=16.8 Pendent Sprinkler TFP318 Model ESFR-1 (TY6226) K=14.0 Pendent Sprinkler TFP319 Model ESFR-14 (TY6236) K=14.0 Pendent Sprinkler System Type Wet Pipe Roof Construction Unobstructed or obstructed con- struction (e.g., smooth ceiling, bar joists, beam and girder, and so forth). Where the depths of the solid struc- tural members (e.g., beams and stem) exceed 12 inches (302 mm), install ESFR Sprinklers in each channel formed by the structural members. Ceiling Slope Maximum 2 inch rise for 12 inch run (16.7%) Maximum Coverage Area 100 ft2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Coverage Area 64 ft2 (5,8 m2) per NFPA 13 / FM Global 2-0 Maximum Spacing 12 feet (3,7 m) for building heights up to 30 feet (9,1 m) 10 feet (3,1 m) for building heights greater than 30 feet (9,1 m). In some cases, installation standards permit a greater spacing. Minimum Spacing 8 feet (2,4 m) Minimum Clearance to Commodity 36 inches (914 mm) NFPA Deflector-to-Ceiling Distance 6 to 18 inches (152 to 457 mm) FM Global Centerline of Thermal Sensing Element-to-Ceiling Distance Refer to FM Global 2-0 for Storage Sprinklers. Specific Application Listing (UL) TYCO Model ESFR-25 Pendent Sprin- klers are listed by Underwriters Labo- ratories (UL) for Specific Applications with a ceiling height greater than 45 ft. (13,7 m) up to and includ- ing 48 ft. (14,6 m), and a storage arrangement up to and including 43 ft. (13,1 m), the following guide- line are provided for the TYCO Model ESFR-25 Pendent Sprinklers: Sprinkler Position Pendent: Frame arms aligned with pipe Deflectors parallel with ceiling or roof System Type Wet Pipe only Maximum Area of Coverage 100 ft2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Area of Coverage 64 ft2 (5,8 m2) according to NFPA 13 Maximum Slope Ceiling 2 inch rise for 12 inch run (16.7%) Maximum Spacing 10 feet (3,1 m) In some cases, the installation stan- dards permit a greater spacing. Minimum Spacing 8 feet (2,4 m) Temperature Rating 165°F (74°C) and 212°F (100°C) Deflector Distance from Walls Minimum of 4 inches (102 mm) from walls but no more than 1/2 the allow- able distance permitted between sprinklers Deflector to Top of Storage Minimum of 36 inches (914 mm) Deflector-to-Ceiling Distance 6 to 14 inches (152 to 356 mm) Maximum Ceiling Height 48 feet (14,6 m) Maximum Storage Height 43 feet (13,1 m) Storage Arrangement Palletized, solid piled, open frame, single row, or double row Commodity Class l-IV; Cartoned, unexpanded plastic Sprinkler System Design NFPA 13 for ESFR Sprinklers based upon 45 psi (3,1 bar) design pressure, 169 gpm (640 1pm) with 12 sprinkler remote area Minimum Aisle Width 5 feet (1,5 m) TFP3I2 Page 4 of 4 LM "FITTING SIDE" T~OWARDS SPRINKLER FITTING WRI RE( FIGURE 2 W-TYPE I SPRINKLER WRENCH Installation TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Damage to the fusible Link Assem- bly during installation can be avoided by handling the sprinkler by the frame arms only (i.e., do not apply pressure to the fusible Link Assembly), and by using the appropriate sprinkler wrench. Failure to do so can lead to an unstable link assembly and premature activation of the sprinkler. Damaged sprinklers must be replaced. A leak-tight 1 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 20 to 30 lbs.-ft. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Note: Install the Model ESFR-25 Pendent Sprinkler in the pendent posi- tion (Ref. Figure 2). Step 1. With pipe thread sealant applied, hand-tighten the sprinkler into the sprinkler fitting. Do not apply pres- sure to the Link Assembly, and handle the Model ESFR-25 Pendent Sprinkler only by the Frame arms. Step 2. Wrench-tighten the Model ESFR-25 Pendent Sprinkler using only the W-Type 1 Sprinkler Wrench (Ref. Figure 2) and by fully engaging (seating) the wrench on the sprinkler wrench flats (Ref. Figure 1). Step 4. After installation, inspect the Link Assembly of each Model ESFR-25 Pendent Sprinkler for damage. In par- ticular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assem- bly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. Care and Maintenance TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number Sprinkler Assemblies Specify: Model ESFR-25 Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226), (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) ..................58-441-1-165 212°F (1 00°C) .................58-441-1-214 Special Order Sprinkler Assemblies with ISO 7-1 Thread Connection Specify: Model ESFR-25, Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226) with ISO 7-1 thread connection, (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) .................. 58-442-1 -165 212°F (100°C) .................58-442-1-214 Sprinkler Wrench Specify: W-Type 1 Sprinkler Wrench, P/N 56-872-1-025 GLOBAL HEADQUARTERS 11400 Pennbroôk Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. tqco MONEL and INCONEL are trademark of Special Metals Corporation. Fire Protection Products TEFLON is trademark of DuPont Corporation. tqcci Fire Protection Products Worldwide Contacts I www.tyco-fire.com Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2'S NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/barl'2) FEBRUARY 2014 Temperature Rating 1350 F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 2-7/8" (73,0 mm) DIA. TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN 7/16 I (111mm) NOMINAL ____ 2 1 Ll MAKE-IN (50,8 mm) 2 I 1-3/8 (50,8 mm) LV (34,9 mm) WR I Fl 1/2 NPT** DEFLECTOR* STYLE 150r20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 1 . Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8" DIA. (73,0 mm) 2-1/4' DIA. FACE OF (57,2 mm) 5/8" (15,9 mm) SPRINKLER FITTING FLUSH 3/8±5/16" (9,5±7,9 mm) [I I 1/8" MOUNTING 2_MM) J SURFACE CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON -. 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) 5/16±1/4" \ r 1/2(12,7 mm) (7,9±6,4 mm) FLUSH 177,17, MOUNTING (3,2 mm) SURFACE/// crL \ CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8 (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N* 77 - XXX - X - XXX I SPRINKLER TEMPERATURE I FINISH I RATINGS SIN I NATURAL BRASS 370 5.6K UPRIGHT (1/2NPT) TY313 3 PURE WHITE (RAL9010)** 155 155°F(68°C) POLYESTER 371 5.6K PENDENT (1/2NPT) TY323 4 SIGNAL WHITE (RAL9003) 175 175°F(79°C) POLYESTER Use suffix "l for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I - Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F(57°C) 200 200°F (93°C) 286 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. t co TEFLON is trademark of The DuPont corporation. 11Fire Protection Products I LLEABLE 11~wlll I 0 Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature _____________ Pressure Class 150 Class 250 Class 300 (°F) (°C) psi tar psi bar psi bar -200 to 1500 -28.90 to 300 65.60 20.7 500 34.5 60C' 41.4 2000 93.30 265 13.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31.7 3500 176.70 150 1.23 315 21.7 415 28.6 400° 204.4° 1 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260,00 - - 180 12.4 280 19.3 5500 287.80 - - 130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F c®Us APPROVED For Listings/Approval Details and Limitations, visit our website @ www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 /4 Sizes -1" (6-25 mm) Sizes 1V'-2 (32-51 mm) Sizes 21/2."-3" (54-76 mm) (°F) (°C) psi ar psi bar psi bar psi bar -200 to 1500 -28.90 to 300 20.7 2,000 65.60 137.9 1,500 103.4 1,000 68.9 2000 93.3 265 78.3 1 1,785 123.1 1,350 93.1 910 62.7 2500 121.1 225 75.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 72.8 1,360 93.8 1,050 72.4 735 50.7 3500 176.7 150 0.3 11 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 550° 287.8 - - 300 20.7 1 300 20.7 300 20.7 .2 0 Anvil Class 150/300 MalLeable Iron Fittings conform to ASME j B16.3 and Unions conform to ASME 616.39. 1 ALL ELBOWS & TEES °/ (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) I I U U U Le..: j2: I -.--- -.----- -- El UI _V" L UI I%lnl c®us LISTED <9> APPROVED I] A4,ONFSA NFPA 2 ull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers - and to promote business growth by -. achieving superior financial performance. • www.BullMooseTube.com SCHE • 800.325.4467 SCHEDULE sales@bullmoosetube.com EDOYTHREAD 40 DY FLOW 1 411 ULTRA EDDY kL BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED <1> APPROVED 1] ONFSA NFPA - -I ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®. Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grand e, Arizona; Kent, Washington; and Dallas, Ièxas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UI.. listed sprinkler pipe, Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance rdtiu oIl .0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Scliedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and withOut incurring obligation. uII Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved'and listed.' Our Schedule 10 and Schedule 40 have a presurêTatii of 300 PSI and have been through the same rigorous testing as our other fine - pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Wow TuIjc1 Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM 4123 stadards. All pftidudae stencilled to meet FM-&UL specifications. - c®us LISTED <8> APPROVED I;] 4 ONFSA NFPA® ri SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 1527 141 lbs/ft 1.820 91 11/4 - 1 *660 f44 991 —61 - 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 [ 2 23 2157 IC 4.223_TL 37j 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 P 3 1r3.560 3.260 354 [434lbs/WjL 7957 19] 4 4.500 4.260 2.50 5.62 lbs/ft' 11.796 19 - SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1:1/4 1660 j[ T380 1.00 [227 lbs/ftL 2918 '[ -- 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft - 3.602 44 - - L 2 iF 2375 2067J 100 1r3661b5/ft1r 5.114 30 2-1/2* 2.875 2.468 - 1.00 5.80 lbs/ft 7.875 - 30 LIIII1 350O 3068 JE100 [ 758165/ft IL 10783 4* 4.500 4.026 1.00 1080 lbs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces thoiild he cleaned prior In installation. In ordei to provide a Wk-fight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Fdilure to take these iniportarlt steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road - - Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, TX Masurt OH BULL IVIDOSE TUBE COMPANY 63017 FireLock® Outlet-I ® ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'% through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Approved Date www.victaulic.com VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REV G X.A-c-tau-637 1.0.52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-I inches/mm Dimensions - inches/millimetefs 1¼ ½ 13A6 130 183 110 387 2.56 10 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 3/4 1 3A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 /I6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 1/2 1 3A6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 34 1 3/io 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1 3/16 1.64 2.30 1,22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 ½ 13A6 1.66 2.19 1.46 4.60 2.56 1.3 50 15 3a2 - 42 55.6 L ._37. 3/4 J.2 1 1/16 1.64 2.19 1.46 4.60 .....................0.59 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 371 116.8 65.0 0.68 2112 ½ 1/6 1.91 2.44 1.71 5,40 2.56 1.6 65 15 30.2 48.5 62.0 j 43.4 137.2 65.0 0.73 3/4 13A6 1.89 2.44 1.71 5.40 2.56 1,6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1/6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 ½ 1 1/16 1,91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 Jul 1 48.5 62.0 1 43.4 139.7 650 0.73 3/4 13A6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 13A6 2.13 2.79 1.71 5.50 2.56 1.7 25 1 30.2 54.1 70.9 43.4 1 139.7 1 65.0 0.80 STYLE 922 DIMENSIONS MCI t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 2 Jtauuicr RFV G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-T STYLE 922 PERFORMANCE * Hazen-Williams coefficient of friction is 120 www.victaulic.com I' I... Ai st: a -U1 ii C~ VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV C, 1OS2 FireLock® Outlet-I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete instllation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 vIcTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vIcTAULIc COMPANY. ALL RIGHTS RESERVED. Ai—c—tau—licf 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org RING HANGER 1 thru 4 inch pipe LISTED FOR STEEL/CPVC 1/2 & 3/4 Inch pipe 5 thru 8 Inch pipe SIZE - ROD- 3/8" or 1/2' SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - 203-EX 25511 "- 8" LISTED Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger, To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD 1 WT. 5 WT.+250 UL TEST LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 1 634.75 750 21/2 3/8 118.35 841.75 850 3 318 162.30 1061.50 1050 4 3/8 246.00 148000 1500 5 112 349.45 2000 6 1/2 476.35 ~3805-00 2650 8 1/2 711.00 4050 551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific ,4FCOA'products are exclusively designed to be compatible ONLY with other AFCON products including parts and lhsteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when nois-AFCONproducts have been, or are used. 1/08 Not less than Wood Flooring Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. 1/4 8002957 GST 100 1/4 xl" 210 (7/16' OSB) 25 125 I 670 (3/4 Ply)______ - 1/4 8003957 GST 200 1/4x2 1760 (Fir) 25 125 1/4 - 8004957 GST 300 1/4 x 3 2060 (Fir) 25 125 3/8" 8006957 GST .75 1/4 x 314" 564 (3/4' Ply) 25 125 300 25 125670 1 L 3/8" 8007957 GST 10 1/4x1" 3/'8"-8008957 GST 20 1/4x 2 1760 (Fir) 850 147525 125 3/8 8068925 GST20SS 1/4 x 2 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4x3" Q9JFir) 1500 1475 25 125J 3/8' 8069925, GST 30-SS1/4x 3" 2060 (Fir) 25 125 J 3/88011925 GST 4O1/4x4 21R 25125 3/8"8012925 GST 6O1/4x6"2230 (Fir) 25125 — 11/2"8013925 GST 2 1/4 x 2"1760,Fir) 25 125 1/2" 8014925 GST 2.5-3803/8x2-1/2"2113(Fir) 25 125 :7ETh925 GST 3 1/4x3 2275 (Fir) 25125 1/2' 8016925GST4 1/4x 4"2180(Fir) 25125 1'TTT1T27TT._p175_ GST 6 1/4x6__2230(Fir) - 25 125 ii #14 Black Nut Driver Part # 8113910 ii #14 SW Red Nut Driver Part #8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. "Accommodates up to 3 1/a" x 12 pitch roof. • Reduces installation cost. "Allows 17" deflection from vertical. • Made in the U.S.A. 3/8" 8139957 GSI._ ,JJ±. j257JJy -.1050 1475 25 125 3/8" 8141957 SH-GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Drivel SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact wi:h the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 0 immm. IV' e Floor Joist Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. Not less than 2" nominal width (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4" & 5" pipe 4 Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bottom for mainlines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams, 1/4" 1/4" 8018957 8019957 SWG 100 SWG 200 1/4x1 1/4 x 2" 622 (Fir) 1725 (Fir) 25 25 12_J 125 k E: 3/8 8020957 SWG 10 1/4 xl 622 (Ar) 300 25 li5 /.. =Q= 3/8"8021957 ' 708073925 SWG 20 1/4x2' 1/402 1725 (Fir) - 1725 (Fir)850 25 12T 1050 25 125 #14 SW Red Nut Driver X 3/8" 8022925 SWG 25-380 3/8 X 2-1/2" 2249 (Fir) 1500 25 125 J 3/8" 8023925 SWG 30 1/4 x 3 1884 (Fir) 25 125 1 Part #8114910 - Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver light to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4', 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. Insert the appropriate nut driver into a 3/8" or 1/2"poi"table drill Insert the SAMMYS into the #14S W (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4' 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate not driver for installations.