Loading...
HomeMy WebLinkAbout711 GRAND AVE; 1; FPC2020-0075; Permit((raty of Carlsbad 0 1 FiiiieiI?eijm1t Print Date: 09/14/2020 Permit No: FPC2020-0075 Job Address: 711 GRAND AVE, # STE 1, CARLSBAD, CA 92008 Status: Issued - Active Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2033032113 Track #: Applied: 04/20/2020 Valuation: $104,522.80 Lot #: Issued: 05/01/2020 Occupancy Group: Project 1*: Finaled Close Out: 08/17/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check U: Final Inspection: Project Title: Description: HARUMAMA -SPRINKLER TI (16 HEADS) Applicant: FPContractor: INNOVATIVE FIRE PROTECTION INNOVATIVE FIRE PROTECTION INC DONALD SCHROEDER - 8779 COTTONWOOD AVE, U STE 101 8779 COTTONWOOD AVE, U 101 SANTEE, CA 92071-4457 SANTEE, CA 92071-4457 (619) 593-8200 (619) 593-8200 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov h2cLO2L) cc5 I-'age 1 or i SENJU SPRINKLER CO.,LTD. Commercial Flat Concealed Sprinkler, Pendent. Quick & Standard Response, Standard Coverage. Model: RC-QR, K-Factor: 5.6. SIN: SS9561 GENERAL DESCRIPTION The Model RC-QR Commercial Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and quick/standard response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-QR should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. They are to be used in wet pipe sprinkler systems per NFPA 13. The Model RC-QR has a 5.6 (80.6 LPM/bar1°) K-factor. '.,Fbr extended installation flexibility, the Model RC-QR provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of 1pe lengths. 'The heat sensitivity and water distribution design of Model RC-QR allows for an increased chance of occupants' escape or evacuation in case of fire. However, fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. WARNINGS the Model RC-QR must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. là the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. ltis the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U036884 Date . Jun/i 7/20 14 Page .• 2 of 7 2— X6" ( 52mm) Year of Manufacture SIN : SS9561 NI K—factor: K5.6 __________ Temperature Rating: 167F/77C Control No. : 171R UL Mark FM Mark (I) Bo, (Copper Alloy) E W—A f2 Deflector (Phosphorus Bronze) f Gasket (PTFE) ® Fusible Metal (Solder) t Heat Collector (Copper) (I) Cover Plate Assembly rking (Deflector) 'Marking (Deflector) 2— 5/s" (68mm) 0r3—y4" 83 mm) LSIN : S59561 I—K—factor: K5.6 or UL only: 2— 5/s" square (068mm) I—Temperature Rating : 167F/72C l—UL Mark LFM Mark FIGURE 1. Model RC-QR K=5.6 TECHNICAL DATA Approvals: UL 5 Listed I as Quick Response FM Approved /as Standard Response Sprinkler Identification Number (SIN): S59561 Maximum Working Pressure: 175psi (12.1 bar) Discharge Coefficient (Nominal K-Factor): K=5.6 GPM/p51112 (80.6 LPM/bar112) Temperature Rating: 162'F I 72°C Sprinkler 140'F / 60°C Cover Plate Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on page 7 for more detail. Physical Characteristics: Ref. Figure 1 OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) DESIGN CRITERIA The Model RC-QR sprinklers are listed by UL and C-UL as quick response I standard coverage for use in accordance with NFPA standard, also the model is FM Approved as a Standard Response, No-Corrosive Atmospheres. The herein stated rules for use and installation of the Model RC-QR are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Document No. U036884 Date Jun/1 712014 Page . 3 of 7 Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13 or by the authority having jurisdiction. The Model RC-QR must not be used in applications where the air pressure above the ceiling is greater than that below. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-QR. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13. General Service Conditions The Model RC-QR must only be utilized in WET PIPE sprinkler systems per NFPA 13. Operational Sensitivity Criteria For proper operational sensitivity, the Model RC-QR must be installed beneath a solid ceiling having a smooth or textured surface. Heat Source Criteria Refer to NFPA 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-QR, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-QR should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. INSTALLATION The Model RC-QR must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft.Ibs (9.5 to 19.0Nm) to achieve a 1/2 inch NPT sprinkler joint. A maximum of 21 ft.lbs. (28.5 Nm) of torque is to be used to install sprinklers. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Document No. U036884 Date Jun/17/2014 Page : 4 of 7 In case of insufficient adjustment in Cover Plate installation, do not fry to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installinc, Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Step 4 Use the Cap Remover RC Tool to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Make a Space Here Do NOT Groove on the SDrinkler Mi W (3.2,rne) E El Tolerance Limit Ave. Y4' (6.4,mn) Over—Tighten Protective Cal) El of Ceilinq Level ilin Ig Mounting Surface Groove of the Socket Ceiling Hole Diameter S G / Wrench [RRECT FIGURE 3. INSTALLATION FIGURE 4 Document No. U036884 Date Jun/i 712014 Page 5 of Sprinkler Head Protective Ca IF I Step 1 Cap Remover RC Step 2 Hook by turning Step 3 J Pull down FIGURE 5. PROTECTIVE CAP REMOVAL Cu oR Ceiling `71,72-7 E Screw Cover Plate Assembly L 2%"(68mm) J or 3- )/" (t 83mm) or UL only: 2- 5/s" square (068mm) FIGURE 6 JINCORRECTI CORRECTi I INCORRECTI FIGURE 7. INSTALLATION (CORRECT OR INCORRECT) Document No. U036884 Date . Jun/I 7/2014 Page 6 of 7 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-QR. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F/40C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100°F/38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No. U036884 Date Jun/1 712014 Page 7 of 7 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-QR (SS9561, Quick & Standard Response, Standard Coverage, Flat Concealed Sprinkler, Pendent, K5.6) Cover Plate Assembly: Listed :2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler FM Approved :2-5/8 inch ( 68mm) or 3-1/4 inch (q 83mm) , Order Separately from Sprinkler Please refer to the chart below for available sizes, and finishes. Standard Finishes Custom Finishes lMie Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8 Round, 140°F 0 0 - - - 0 - 0 0 3-1/4"Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8' Square, 1400FX1 0 - - - - - - 0 0 wi UL5 listed only Tools for Installation of Model: RC-QR Socket for Model RC-QR Wrench & Socket for Model RC-QR Cap Remover RC Document No. U036884 Date . Jun/I 712014 Horizontal Sidewall .;. .4 I:;. . .. .• Concealed Pendent Recessed Pendent/Fl/F2 Recessed Pendent/FP Bulletin 014 Rev, N ileflabk® Model Fl FR Series Quick Response Glass Bulb Sprinklers '4 Model F1FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus). FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) NSF Certified to NSF/ANSi Standard 61 Annex G (NSF) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Reliable Automatic Sprinkler Co., Inc., 103 Upright Pendent Conventional Vertical Sidewall f ¶L)H Recessed Horizontal Sidewall XLH Upright XLH Pendent Pendent F1/F2 Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment, In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 t 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Anal adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN mm Listings and Approvals Approval Notes US Metric inches mm inches F1FR28 2.8 40 3/8 10 Pendent 2.25 57 D RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 D RA 1418 VdS Recessed Pendent 2.25 57 GFR2 RA 1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2,25 57 D RA1410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 1 57 D RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 0 RA1414 cULus, FM , LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 , LPCB cULus FM, , VdS, EC 1,2,3,4 "Conventional 2.25 57 (Pendent or Upright)" D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 0 RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5,6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 D RA1485 cULus, FM, LPCB 1,2,3,9 (II cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. 4) Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12. 7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (°) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector, Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1070C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb I Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus -- _________ Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS I -- Pendent cULus F1FR42 Recessed Pendent cULus I -- _________ Upright cULus Pendent -- cULus, Ni -- F1FR42LL _________ Recessed Pendent -- cULus, NSF -- Pendent cULus F1FRXLH Recessed Pendent cULus I -- _________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- F1FR56 Concealed Pendent* cULus I cULus,VdS,EC I cULus -- Upright cULus, FM, LPCB, VdS, EC Conventional (Pendent or Upright)" LPCB VdS EC Pendent -- cULus, NSF -- F1FR56LL Recessed Pendent -- cULus, NSF -- ________ Concealed Pendent* -- cULus, NSF -- Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal Sidewall cULus, FM -- Fl FR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For lnterrñediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector/ Orientation Listed and Approved Recessed Escutcheons SIN Model Fl (Fig. 1 & 3) 3/4-inch (19mm) adjustment Model F2 (Fig. 1 & 3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment Fl FR28 Recessed Pendent cULus cULus cULus RA141 1 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA 1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC cULus, FM, LPCB , VdS,EC cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS Fl ESCUTCHEON_L. 3/4 "[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT 2 7/4" HOLE 0/A. [5 7.2mm] 7 15/76" 0/A [49.2mm] (1 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 '[25.4mm] AT MINIMUM RECESS = 3/8'[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4(19mm] -7777/ / AT MINIMUM RECESS = 3/8 "[9.5mm] A Fl ESCUTCHEON AT MAXIMUM RECESS = 7/8 "[22.2mm] [3.2mm] / AT MINIMUM RECESS 1-5/8"[4 1.3mm] r F2 ESCUTCHEON AT MAXIMUM RECESS = I - 1/8(28.6mm] IF AT MINIMUM RECESS = 1-5/8 '[41.3mm] 2 27/32" 0/A. [72.2mm] Fig. 1 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon T 2 5/8" DIA, [66.7mm] HOLE IN CEILING / 2 5/16" DIA, [58,7mm] - - CUP _ CEILING- 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAX/MUM RECESS = 1-1/2 "[38mm] AT MINIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 1 "[25.4mm] ADJUSTMENT I Y2"[12,7mm] J I AT MAXIMUM RECESS = 9/16"[14,3mm] 3 1/4" DIA. [82.6mm] Fig.2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5' Fl ESCUTCHEON I/A AT MAXIMUM RECESS = 1-3/8"[34.9mm] H AT MINIMUM RECESS = 2- l/16"[52.4mm] F2 ESCUTCHEON I AT MAXIMUM RECESS = 1-5/8 "[41.3mm] AT MINIMUM RECESS = 2- l/16"[52.4mm] I A72 1 (1) 4"-12" [10 1.6mm-304.8mm] 32 DIA CEILING TO [72.2mm] DEFLECTOR . Fl ESCUTCHEON -H 3/4 "[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12. 7mm] ADJUSTMENT FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAX/MUM RECESS = 3/4 "[19mm] AT MINIMUM RECESS = 3/8 "[9.5mm] 2 1/4" HOLE 0/A. [5 7.2mm] 1" X 1/2" REDUCER I I 15/16" DIA.4jJ,4 [49.2mm] 11111 I -- L.. TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW TT -- 2 5/8" DIA. 2 5/16" DIA - L1 HOLE IN CEILING CUP 1 1/2" MAX. FACE OF FITTING 1 __.TO FACE OF CEILING DIMENSION CEILING-' 1/2" MAX. I COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER 15/16" 3 5/16" DIA. CONCEALED, 1/2" ADJUSTMENT Fig.4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate 101 I" x 1/2" REDUCING TEE OR ELBOW 2 CEILING 5/16" COVER ADJ COVER AS. 5/8" 0/A. IN CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" SPRINKLER CONCEALED, 5Z16" ADJUSTMENT 0177402A Fig. 5- Model Fl FR56I1`1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover platet1 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate" Electroless Nickel PTFE(7 Electroless Nickel PIFE Bright Brass Bright Brass31 Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6) Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant 7 Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR4O][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][ 175°F (79°C)][200°F (93°C)][286°F (141°C)) Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile COP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model Fl FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Aft compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled H ®R (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax eliable (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 12/15 P/N 99999703w I Horizontal Sidewall (See Fig. 5) (See Fig. 6) (See Fig. 7) I Recessed Fl Horizontal Sidewall (See Fig. 9) Horizontal Sidewall (See Fig. 8) Upright (See Fig. 10) Bulletin 153 November 2019 llablL~ Features 1 Available in the following configurations: Pendent with standard escutcheon Pendent with Model HB extended escutcheon Pendent with Model FP recessed escutcheon Pendent with Model Fl recessed escutcheon Concealed Pendent with Model CCP cover plate Horizontal Sidewall with Standard escutcheon Horizontal Sidewall with Model HB extended es- Model F3-56 Dry K56 (80 metric) Standard-Response, Standard Spray Sprinklers 4 IW cutcheon Horizontal Sidewall with Model FP recessed es- cutcheon Horizontal Sidewall with Model Fl recessed es- cutcheon Upright Available with 1" NPT, 1S07-1R1, 3/4" NPT, or 1S07- 1 R3/4 inlet fitting. 3/4" NPT inlet fittings permit replacement of older 3/4" inlet dry sprinklers without changing to a larger sprin- kler fitting. Sprinklers, escutcheons, and cover plates are avail- able in a wide variety of standard and special appli- cation finishes. cULus Listed as Corrosion Resistant when ordered with select finishes (see Finishes chart). Available with cULus Listed 250 psi (17.2 bar) pres- sure rating for Dry Pendent and select HSW configu- rations. Other approvals are for 175 psi (12 bar). Product Description Model F3-56 Dry sprinklers are standard-response, stan- dard coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). Available in Dry Pendent, Dry Horizontal Sidewall and Dry Upright configurations, Model F3-56 Dry sprin- klers all use a 5 mm glass bulb operating element. See the Temperature Ratings table in this Bulletin for available tem- perature ratings. Model F3-56 Dry sprinklers are intended for installation on wet-pipe, dry-pipe, or preaction sprinkler systems in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other applicable installation standards. Model F3-56 Dry Pendent and Sidewall sprinklers are available with a variety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Mod- el F3-56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in Fig. 4. Available sprinkler, escutcheon, and cover plate fin- ishes are identified in the Finishes table in this Bulletin. The Model El escutcheon, Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F3-56 Dry sprinklers; the use of any other recessed escutcheon or cover plate with Model F3-56 Dry sprinklers will void all guarantees, war- (See Fig. 1) (See Fig. 2) (See Fig. 3) (See Fig. 4) Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 ranties, listings and approvals. Inlet fittings are available with 1" NPT, ISO 7-1 Ri, 3/4" NPT, or lS07-1R3I4 threads. Sprinklers with 3/4" NPT and 1S07- 1 R3/4 inlet fittings are intended primarily for replacement of existing 3/4" or 1S07-1 R3/4 inlet dry sprinklers, but may also be used in new installations. See the Available Configurations, Listings, and Approvals table in this Bulletin for further information on Model F3-56 Dry sprinklers. Available Configurations, Listings, and Approvals Available Sprinkler Sprinkler Escutcheon or Length Listings and Inlet Identification Model Cover Plate (See Figs. 1-9) Approvalst1 Threads Number (SIN) Standard 2" to 36" Escutcheon (50 to 900 mm) HB Extended Escutcheon cULus, NYC 3/4" NPT or Fl Recessed Escutcheon 3-1/2" to 36" lSO7-1R3/4 (90 to 900 mm) FP Recessed Escutcheon COP Cover Plate F3-56 Dry Pendent Standard 2" to 48" R5314 Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus, FM, NYC, 1" NPT Fl Recessed LPCB, CE, or Escutcheon 3-1/2" to 48" VdS12 ISO7-1R1 (90 to 1200 mm) FP Recessed Escutcheon COP_ Cover _Plate Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus131, NYC(3) 3/4" NPT 3-1/2" to 48" or 1507-1 R3/4 Fl Recessed Escutcheon (90 to 1200 mm) FP Recessed F3-56 Dry Escutcheon Horizontal R5334 Sidewall Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended cULus13 , Escutcheon FM141, NYC131, 1" NPT 3-1/2" to 48" LPCB, CE or ISO7-1R1 Fl Recessed Escutcheon (90 to 1200 mm) FP Recessed Escutcheon F3-56 Dry Upright N/A 5" to 48" cULus 1" NPT or R5324 (127 to 1200 mm) lSO7-1R1 "For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. VdS approval is for Standard Escutcheon version only. cULus Listing and NYC for Light Hazard and Ordinary Hazard only. FM Approved for Light Hazard only. 2. Patents Model F3-56 Dry series sprinklers may be covered by one or more of the following patents: US Patent No. 5,775,431 US Patent No. 5,967,240 Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) Certified by FM Approvals (FM) Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Loss Prevention Certification Board Approved (LPCB) CE Listed 0832-CPD-2006 (CE) VdS Schadenverhutung GmbH (VdS) Technical Data Nominal K-Factor: 5.6 gpm/psi 2 (80 L/min/bar112) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3-56 Dry Pendent cULus, NYC See note below 250 psi (17.2 bar) FM, LPCB, CE, VdS See note below 175 psi (12 bar) F3-56 Dry Horizontal Sidewall cULus, NYC ___________________________ 4" to 6' 250 psi (17.2 bar) 4 to 12 175 psi (12 bar) FM, LPCB, CE See note below 175 psi (12 bar) F3-56 Dry Upright cULus See note below 175 psi (12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification is necessary. Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceiling Temperature Listings and Approvals" Ordinary Orange 135°F (57°C) 135°F (57°C) 100°F (38°C) 155°F (68°C) cULus, FM, NYC, LPCB, CE Red Intermediate Yellow 175°F(79°C) 1650F(74°C) 150°F(660C) cULus, NYC Intermediate Green 200°F (93°C) 165°F (74°C) 150°F (66°C) cULus, FM, NYC, LPCB, CE High Blue 286°F(141°C) None 225°F (107°C) cULus, FM2, NYC 165°F (74°C) 150°F (66°C) cULus, NYC For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes(6) Component Sprinkler Escutcheon() Cover Plate Standard Finishes Bronze Brass131 White Paint White Polyester (2) White Polyester Chrome Chrome Chrome Special Application Finishes Electroless Nickel PTFE 2' Electroless Nickel PTFE Black Polyester Customer Color Polyester Satin Chrome Black Paint Custom Color Paint Black Plating Black Polyester (2) Custom Color Polyester Wax Coated(2114) _______________________________ High Temp. Wax Coated(2115) Lead Plated(2114) Wax Over Lead(2114) High Temp. Wax Over Lead(2115) 11 Standard and Model HB escutcheons are supplied with both the can and escutcheon finished, Model Fl escutcheons are supplied with both the collar and escutcheon finished. Model FP escutcheons are supplied with the escutcheon finished; the cup is galvanized steel with no further finish. 2) cULus Listed as a Corrosion Resistant Sprinkler. Brass finish available for standard, Model Fl, and Model FP escutcheons only. 41 Wax coating, lead plating, and wax over lead finishes are cULus Listed and NYC permitted only; listing is limited to 155°F (68°C), 175°F (790C), and 200°F (93°C) activation temperature sprinklers only. ) High temperature wax coating and high temperature wax over lead finishes are cULus Listed and NYC permitted only; listing is for 286°F (141°C) activa- tion temperature sprinklers only and shall only be installed where maximum ceiling temperature does not exceed 150°F (66°C). 161 Dry upright sprinkler available in standard bronze only. 0 Model F3-56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5314) "A" Dim 2' to 48" (51 mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 2" to 36" (51mm to 914mm) in 1/4" (6mm) increments for q/4" connertirn System Fitting Inlet Fitting "A" Dimension [54mm] - Dia. 1-1/4" Hole in Ceiling Sprinkler Can [32 mm] - Escutcheon Adjustment Escutcheon 15/32" / P[l2mm] ..''Ceilrnq * Nominal Escutcheon Position 1/4" [6 mm] Escutcheon Adjustment 1/4" [6 mm] Nominal Protrusion - [76 mm] DIA. 1 -5/8" [41 mm] CCMDRYDET1 Fig. 1 Note: The sprinkler can protrudes ¼" when escutcheon is in nominal position. Escutcheon adjustment provides -¼" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model 02 Model F3-56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5314) "A" Dim 31/2" to 48' (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2 to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections if1) i System tee Inlet fitting "A" Dimension 2-1/2" [64 mm] Die, Hole in Ceiling 1/2" [13mm] [_ Escutcheon Adjustment .'Ceiling Nominal. Position f /4" / Escutcheon of Escutcheon I I r-----Sprinkler Can 1/2" [13mm] Escutcheon Adjustment COMDRYDET2 3-1/2" [89 mm] Escutcheon Die. Fig, 2 Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides 1/2" (-12.7mm) to +½" (+12.7mm) "A" dimension adjustment range. Sprinkler Guard: Model C2 5. Model F3-56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5314) "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4' (6mm) increments for connections or Or I I L_L----j System Tee Inlet Fitting 2-5/8" [67 mm] Dia. "A" Dimension Hole in Ceiling I Sprinkler 1/4" [6 mm] I Cup Escutcheon Adjustment Escutcheon Celllngjj J 3/4" [19 mm] Nom. Nominal EscutcheonPosition 1/4 [6 mm] 3-7/32" Escutcheon Adjustment [82 mm] Dia. - COMDRYDET3 Fig. 3 Note: Do not install the Model F3-56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. Model F3-56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5314) "A" Dim 31/2 1048" (89mm to 1219mm) in 1/4' (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections _______ - I I ll L__L----J L System Tee Inlet Fitting 'J-''-'• "A" Dimension Hole in Ceiling Sprinkler Cup 3/16" 15 mm] Model CCP 1/2 Cover Plate Adjustment Cover Plate Assembly Nominal Cover Plate Position Ceiling ' 3/16" [5 mm] Cover Plate Adjustment 3-5/16" [84 mm] Dia. COMDRYDET4 Fig. 4 Note: Do not install the Model F3-56 Dry Pendent sprinkler with the Model COP cover plate in ceilings which have positive pressure in the space above. 7. Model 173-56 Dry Pendent Sprinkler with Model Fl Recessed Escutcheon (SIN R5314) "A" Dim 31/2' to 48" (89mm to 1219mm) in 1/4' (6mm) increments for 1" connections or 131/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections. I III L - - System Tee Inlet Fitting 2-1/4" [57 mm] Dia. Hole in Ceiling "A" Dimension 1/4" [6 mm] Escutcheon Adjustment 1/8 j73mm] Nominal Escutcheon Position Escutcheon 1/4" [6 mm] Escutcheon Adjustment 2-27/32" [72 mm] Dia. COMDRYDET5 Fig. 5 91 System Fitting Model F3-56 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5334) "Di 2" to 48" (51 mm to 1219mm) in 1/4" (6mm) increments for 1" connections or Dim. 2' to 36" (51mm to 914mm) in 1/4" (6mm) increments for 3/4" connections Ceiling ItJ [102 mm] Mm. Sprinkler Can 15/32' 12 [305 mm] Max. Inlet Fitting ; - 5/8" 16 mm] 311 [76 mm] COMDRYDET6 2-1/8' [54 mm] Dia. Hole in Wall 1-1/4" [32 mm] Escutcheon Adjustment "A" Dimension - j- 1/4" [6mm] Nominal Protrusion 1/4" [6 mm] Escutcheon Adjustment Nominal Escutcheon Position Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides -¼" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Model F3-56 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5334) "A" Dim 3/2" to 48' (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 3½' to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4' connections Ceiling 4" [102mm] Mm. - Escutcheon 12" [305mm] Max. Sprinkler Can 2 3/32" System Tee Inlet Fitting - [53mm] - 5/8" [1 6mm] 3-1/2" -- -- -- --- - [89mm] Escutcheon Dia. 21/2"Dia 1-1/4" 1-1/4" [32mm] Nominal Protrusion Hole in Wall [32mm] 1/2"[13mmJ Escutcheon Adjustment COMDRYDET7 1/2" [13mm] Nominal Position Escutcheon of Escutcheon Adjustment "A" Dimension - Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides 1/2" (-12.7mm) to +1/2" (+ 12.7mm) 'A' dimension adjustment range. 10. Model F3-56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN "A" Dim 31/2' to 48(89mm to 1219mm) in 1/4"(6mm) increments for 1" connections or 31/2' to 36(89mm to 914mm) in 1/4(6mm) increments for 3/4" connections Ceiling Nom. 1-1/4 - Escutcheon [32 [32 mm] 4" [102 mm] Mm. Sprinkler Cup cULus, NYC: 6" [152 mm] Max. System Tee "\ ' FM: 12' [305 mm] Max. Inlet Fitting I 5/8" [16 mm] 1/ 3-7/32" L 11 1 — [82 mm] Dia. 2-1/2" [64 mm] Dia. Hole in Wall 1/4" [6 mm] Escutcheon Adjustment COMDRYDET8 1/4" [6 mm] -- Nominal Escutcheon Position Escutcheon Adjustment "A" Dimension iI Note: Do not install the Model F3-56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. / 11. Model F3-56 Dry Horizontal Sidewall Sprinkler with Model Fl Recessed Escutcheon (SIN R5334) 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 3½"to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections H: Nom. 1-3/4 [44 mm] 1/8' Escutcheon [3 mm] 4" [102 mm] Mm. Collar N I I cULus, NYC: 6" [152 mm] Max. System Tee FM: 12" [305 mm] Max. / Inlet Fitting 7 5/8" [16 mm] _ 2-27/32" ____ [72 mm] Dia. 2-1/4" [57 mm] Dia. Hole in Wall 1/4" [6 mm] Escutcheon Adjustment Nominal Position COMDRYDET9 1/4" [6 mm] -H of Escutcheon Escutcheon Adjustment "A" Dimension Fig. 9 12. Model F3-56 Dry Upright (SIN 5324) Order Dimensions 5" to 48" (127 mm to 1219 mm) Note: Customer is responsible for determining correct deflector distance below structure above. Order Dimension Inlet Fitting System Tee I huh1 I I 11111 I I I II L f------------m J COMDRYDET10 Fig. 10 13. MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH APPLIES TO ALL STYLES OF DRY SPRINKLERS CONNECTED TO A WET PIPE SYSTEM. AMBIENT TEMPERATURE EXPOSED TO DISCHARGE END OF SPRINKLER" (F EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50'F/10'C I 65'F/16'C EXPOSED MINIMUM BARREL LENGTH" "" CE OF FITTING TO TOP OF CEILING) IN. (MM) IN. (MM) IN, (MM) 40Y (4C) 0 0 0 3SF (-iC) 0 0 0 20F (-7'C) 4 (105) 0 0 I.(-12'C) 8 1250) (25) 0 OX (-18'C) 12 (300) 3 (75) 0 -lOX (-23C) 14 (350) 4 (100) 1 (25) -207 )-29'C) 14 (350) 6 (150) 3 (75) -30F )-34'C) 16 (455) 6 (250) 4 (100) -40'F (-40'C) 18 (450) I 8 (200) 4 (100) -50F (-46C) 20 (505) IS (250) I 6 (150) -60F (-510) 20 (500) I IX (250) 6 (150) FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE "A" DIMENSION. THE MINIMUM EXPOSED BARREL LENGTH IS BASES ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WINO VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED, THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION. WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. WET PIPE T WI- -lj(th IF HUMIDITY AND TEMPERATURE DIFFERENTIAL / CAUSES CONDENSATION ON THE EXPOSED DRY / SPRINKLER. CONSIDER WRAPPING THE EXPOSED \ / BARREL WITH INSULATION, FOAM INSULATING / TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) / SEAL THE CLEARANCE SPACE EXPOSED ' / AROUND THE SPRINKLER TO AVOID BARREL / LEAKAGE OF AIR INTO THE PROTECTED LENGTH / AREA AND CONSEOUENT FORMATION OF I DIMENSION CLEARANCE HOLE -)--- I CONDENSATE AROUND THE FRAME, WHICH - / COULD INHIBIT OPERATION OR CAUSE / PREMATURE OPERATION, SEE BELOW FOR / RECOMMENDED METHODS. INSIDE SURFACE OF , INSULATION, WALL, OR I ---, CEILING THERMAL ESCUTCHEON END OF SPRINKLER PROTECTED (NON-CONDITIONED) AREA) RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) WET PIPE '\ i9lI --------- 1W i - - 1W - W"i" I I I (HEATED AREA) (HEATED AREA) ,, I) MINIMUM EXPOSED BARREL LENGTH DECKTITE FLASHING (SEE ABOVE) RASCO #4053810 (RECOMMENDED) -if --- CLEARANCE HOLE I INSULATED FREEZER,- OR COOLER STRUCTURE OR EXTERIOR FRAMING (PROTECTED AREA) JJJ{J)_- DISCHARGE END OF DRY SPRINKLER IN COLD AREA )PROTECTED AREA) DISCHARGE END OF DRY SPRINKLER IN COLD AREA C SM DR TO E Ti INSIDE FACE MINIMUM EXPOSED BARREL LENGTH (SEE ABOVE) *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damage the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet-pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal Obstruction Obstruction Pipe Female Female Pipe Thread—,-," CPVC Fitting with Internal Obstruction CPVC itting - No Internal Obstruction Shorter Longer Inlet Inlet ale Male -______ _____ j'i Pipe Pipe Thread Thread __ M 7 17 Dry Sprinkler Dry Sprinkler Short Inlet ("FL) Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYOET2 Fig. 12 15. Fig. 13 - Model F3R Wrench 1T . Fig. 14 - Model XL02 Wrench 16. ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS 051000 3 LOAD SCREW BRASS PER UNS 022000 4 SEAT ADAPTOR BRASS ALLOY PER UNS 036000 5 BULB INSERT COPPER ALLOY PER UNS C31400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS 038000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL (NOT USED ON ALL MODELS) (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) COMDRYDET13 PEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL MATERIAL SPECIFICATIONS Fig. 15 17. Installation Instructions Model F3-56 Dry sprinklers must only be installed in the following fittings: The side outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee The run outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee, with the side outlet plugged (wet-pipe systems only) Spears Manufacturing Company Brass Thread In- sert Style or Special Reinforced Plastic Thread Style Listed adapter or tee (wet-pipe systems only) (gasket sealed outlets shall not be used) Any Listed CPVC sprinkler adapter or tee only in ac- cordance with Fig. 12 and upon verification that the CPVC adapter or tee does not interfere with the sprin- kler's inlet (wet-pipe systems only) (gasket sealed outlets shall not be used) Model F3-56 Dry sprinklers must not be installed into el- bows, welded outlets, or gasket sealed outlets. Installation of the Model F3-56 Dry sprinkler is not recommend in copper pipe systems, as this may reduce the life expectancy of the sprinkler. In all dry-pipe system installations, the Model F3-56 Dry sprinkler must be installed with protrusion into the fitting in accordance with Fig. 1 through Fig. 10 in this Bulletin. Do not install Model F3-56 Dry sprinklers with the standard (long) inlet fitting into CPVC fittings that have an internal ob- struction (see Fig. 12); this will damage the sprinkler, the fit- ting, or both. Model F3-56 Dry sprinklers are available with a short "PL" inlet fitting for installation on CPVC fittings of wet-pipe sprinkler systems only. Model F3-56 Dry sprinklers connected to wet-pipe sys- tems must be installed with the Exposed Minimum Barrel Length required by Fig. 11 located in a Heated Area. An orange protective clip is factory installed on the sprin- kler to protect the glass bulb thermal element from dam- age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Sprinklers with 3/4" NPT and 1507-1 R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: Cut a hole in the wall or ceiling directly in-line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler's inlet fitting. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3R wrenches are designed to be inserted into the groves in the sprinkler's wrench boss as shown in Fig. 13. The Model XL02 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig. 14, Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When insert- ing or removing the wrench from the sprinkler, care should be taken to prevent damage to the sprinkler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22 - 30 lb- ft (30-40 N-m) for 1" NPT and 1507-1R1 sprinklers, and 14- 20 lb-ft (19-27 N-m) for 3/4" NPT and IS07- 1 R3/4 sprinklers. 3a. Alternatively, where access to the outer tube of the sprinkler is available, the Model F3-56 Dry sprin- kler may be installed using a pipe wrench. The pipe wrench shall only be permitted to interface with the galvanized steel outer tube portion of the sprinkler (Item #8 in Fig. 15). Do NOT wrench any other portion of the sprinkler assembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprin- kler because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 - 40 N-m) for 1" NPT and 1507-1R1 sprinklers, and 14-20 lb-ft (19-27 N-m) for 3/4" NPT and 1507-1R3/4 sprinklers. Standard and Model HB escutcheons can be in- stalled by slipping the escutcheon over the can until the escutcheon is seated against the ceiling or wall. Model Fl escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP es- cutcheon is installed by pressing or threading the es- cutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in a counter-clockwise direc- tion. To install the Model CCP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cover plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter-clockwise direction. Remove the orange protective clip when placing the sprinkler system in service. 111 Installation Data Sprinkler Model Escutcheon or Cover Plate Suggested Hole Diameter in Wall or Ceiling Required Centerline of Sprinkler Tube/Inlet to Finished Ceiling Vertical Dimension* Installation Wrench Standard Escutcheon 2-1/8" (54 mm) F3R HB Extended Escutcheon 2-1/2" (64 mm) F3-56 Dr, Pendent Not Applicable Fl Recessed Escutcheon 2-1/4' (57 mm) FP Recessed Escutcheon 2-1/2" (64 mm) XL02 CCP Cover Plate Standard Escutcheon 2-1/8" (54 mm) 4-5/8" to 12-5/8" (118 mm to 321 mm) F3R HB Extended Escutcheon 2-1/2" (64 mm) F3-56 Dry Horizontal Sidewall Fl Recessed Escutcheon 2-1/4" (57 mm) cULus, NYC 4-5/8" to 6-5/8" (118 mm to 168 mm) FP Recessed Escutcheon 2-1/2" (64 mm) ___________________ XL02 Fl Recessed Escutcheon 2-1/4' (57 mm) FM, LPCB, CE 4-5/8" to 12-5/8" (118 mm to 321 mm) FP Recessed Escutcheon 2-1/2" (64 mm) F3-56 Dry N/A 1-1/2" (38mm) Not Applicable F3R Upright I *Note: Based on 5/8" (16 mm) Centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3-56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Replace any sprinkler which has been paint- ed (other than factory applied) or damaged in anyway. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: Sprinkler: [Model F3-56 Dry Pendent SIN R5314][Model F3-56 Dry Horizontal Sidewall SIN R5334] [Model F3-56 Dry Upright SIN R5324] Escutcheon/Cover Plate: [None][Standard escutcheon] [Model HB extended escutcheon][Model Fl recessed escutcheon][Model FP recessed escutcheon] [Model CCP cover plate - pendent only] Inlet Threads: [1" N PT] [1507-1 Al ][3/4" NPT][1507-1 R3/41 Inlet Fitting: [Long - Standard Inlet Fithng][Short 'PL" - Wet Pipe Systems only] Sprinkler Temperature Rating: See Temperature Ratings table Sprinkler Finish: See Finishes Table Escutcheon/Cover Plate Finish: See Finishes Table Length: *For dry pendents and dry sidewalls: "A" Dimension is from face of tee to face of finished ceiling or wall in 1/4" (6mm) increments. See Fig. 1 through Fig. 9. *For dry uprights: Order dimension is from face of tee to top of deflector in 1/4" (6mm) increments. See Fig. 10. Notes: For Dry Upright, customer is responsible for determining the correct deflector distance from structure above. Length is based on normally gauged pipe thread "make- up" of .600" (15mm) per ANSI B2.1 (approximately 7-1/2 threads). The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by - Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper (914) 829-2042 Corporate Offices e (800) 848-6051 Sales Fax Revision lines indicate updated or new data. Reliabl www.reliablesprinkler.com Internet Address EG. Printed in u.S.A. 11/19 P/N 9999970146