Loading...
HomeMy WebLinkAbout560 CARLSBAD VILLAGE DR; 101; AS090102; PermitCity of Carlsbad Sprinkler Permit Permit No: AS090102 560 CARLSBAD Job Address: VILLAGE DR Permit Type: SPRINK Parcel No: 2032922200 Lot #: 0 Reference No.: Status: ISSUED Applied 8/28/2009 Approved: Issued: PC #: Inspector: Project Title: SPEC SUITE #101 T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: SULLY FIRE PROTECTION 1975 SPANISH OAK WAY VISTA, CA 760-727-3444 Owner: HURLEY THOMAS J 1015 CHESTNUT AVE #F2 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance () L 130 0 130 0 Flow Control I Tyco Fire Products 1% \(Dl,--~ D P~o - Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB and 80 K-factor Upright and Pendent Sprinklers Quick Response, Standard Coverage General Description ThSeries TY-FRB, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, :he testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability r these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-FRB Pendent Sprinkler can be obtained by utilizing the Series TY- FRB Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY4131 - Upright 8.0K 3/4"NPT TY4231 - Pendent 8.0K, 3/4"NPT Technical Data Approvals UL and C-UL Listed. FM and LPC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barl/2) K = 5.6 GPM/psi1/2 (80,6 LPM/barl/2) K = 8.0 GPM/psi1/2 (115,2 LPM/barl/2) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated or Chrome Plated. (Other colors are available on request.) Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflonj- Bulb ..............Glass Compression Screw .....Bronze Deflector ...........Copper Bushing (K=2.8) .......Bronze .4— ESCUTCHEON PLATE SEATING SURFACE 7/16" (11,1 mm) NOMINAL -MAKE-IN 1/2" ** NPT 2-3/16" (55,6 mm) i Page 2 of 8 1/2" ** NPT ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) —Li—]" — -.-;-J. 7/16" (11,1 mm) NOMINAL SSU* MAKE-IN DEFLECTOR it(55,6 WRENCH ' 3 DEFLECTOR CROSS uJJ;1[e1:I SECTION - Frame 2 - Button 3 - Gaskeled 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to Spring 5 - Compression 7- Bushing orifice seat on frame. Plate Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TV-FRB IJPRIGHT(TY1I31) AND PENDENT(TY1231) SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT STYLE 100r20 ESCUTCHEON RECESSED SSU* DEFLECTOR tJTJ 7/16 I II " (11.1 mm) :NOMINAL E- IN FLATS _MAK 2-3/16" (55,6 mm) 1/2NPT** I UPRIGHT CAOSS SECTION SSP DEFLECTOR* 1—"- 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT 1 - Frame 3 - Gasketed 4- Bulb 6- Deflector Temperature, rating is indicated on deflector or adjacent to 2- Button Spring 5 - CompressIon orifice seat on frame. Plate Screw **Pipe thread connections per ISO ill can be proved on special request. FIGURE 2 OWCK RESPONSE SERIES TY-FRB UPRIGHT (TY3 13 1) AND PENDENT(7-V3231) SPRINKLERS 5.6 K-FA CTOR, 1/2 INCH NPT SSU* DEFLECTOR 6* 1/2 5 (12,7 mm) NOMINAL 4 MAKE-IN 2 2-1/4 (57,2 mm) ' 314NPT** I UPRIGHT CROSS SECTION Page ioi8 ESCUTCHEON 1/2 (12,7 mm) STYLE 30 or 40 PLATE SEATING ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON NPT 2-5/16 S(58,7 mm) _______ 1-9/16 (39,7 mm) WRENCH FLATS SSP DEFLECTOR 2-7/8 (73,0 mm) DIA. PENDENT RECESSED PENDENT 1 • Frame - 3- Gasketed 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Spring 5 - Compression 7 - Ejection orifice seat on frame, Plate Screw Spring **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT(TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, which then allows the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 require-. ments). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Page 4 of 8 SPRINKLER FINISH (See Note 5) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED IPOLYESTER COATED LEAD COATED 2.8 1/2' NPT PENDENT (TY1231) and UPRIGHT (TYI131) 135F/57°C Orange 1, 2,3 N/A 155°F/68C Red 175F/79°C Yellc.. 200°F/93°C Green 286F/141°C Blue 1/2 PENDENT (TY3231) and UPRIGHT (TY3131) 135F/57°C Orange 1, 2, 3, 4 1, 2,3 155°F/68°C Red 175FT79°C Yellow 200°F193°C Green 286°F/141°C blue NPT RECESSED PENDENT (TY3231) Figure 4 135F/57C Orange 1,2,4 N/A ______ 175F/79°C Yellow 200FI93°C Green RECESSED PENDENT (TY3231)* Figure 5 135F/57C Orange 12,3,4 N/A 155°F/68°C Red 175°F179°C Yellow 200°F/93°C Green 8.0 3/4w PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C .Orange. 1, 2, 3, 4 1,2 155°F/68°C Red 175F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY4231) Figure 6 135Ff57°C Green 12,4 N/A 155°FI68C Orange 175F/79°C Red 200°F/93C Yellow RECESSED PENDENT (TY4231)** Figure 7 1351F15710 Orange 1, 2, 3, 4 N/A 155°F/68°C Red 175°F179°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Council (LPC) as Quick Response Sprinklers; however, the LPC does not rate the thermal sensitivity of recessed sprinklers. 5. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2' NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2' NPT) or Style 30 (3/4' NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. White or Any Color (Frame and Detector only). TABLE A LABORA TORY LISTINGS AND APPROVALS Page 5 of 8 2-7/8' DIA. 5/8±1/4' (73,0 mm) I 3/4' (19.1 mm) (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) FACE OF42mMOUNTING 1/8" SPRINKLE PLATE FITTING (3,2mm) MOUNTIN SURFACESERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 3/4'(19,1 mm) FIGURE SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6K-FACTOR, 1/2 INCH NP - 2-7/8' 01k (73,0 mm) 1/2±1/4' 1/2"(12.7mm) [(127±64mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF PLATE SPRINKLER FITTING L,57'2 mm) MOUNTING - 1/8' I. ____ (3,2 mm) / 11 MOUNTING SURFACE CLOSURE SERIES 1-1/4'(31,8mr TYFRB 1'(25,4 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4' (73,0 mm) 3/4"(19,11 mm) (15,9±6,4mm) - 2-1/4'01A. 1/4" (6,4 mm) FACE OF *R l (57,2 mm) MOUNTING 1/8' PLATE SPRINKLE FITTING (3,2mm) MOUNTIN SURFACE CLOSURE SERIES 1-5/16 (33,3j_________ TYFRB 13/16" (20,6 mm) - 2-7/8' DIA. 1/2±1/4' (73,0 mm) 1/2' (12,7 mm) (12,7±6,4 mm) _ 2-1/4' DIA. 1/4"(6,4 mm) I FACE OF (57,2 mm) MOUNTING SPRINKLER 1/8' R PLATE FITTING (3,2 mm) \ MOUNTING I SURFACE CLOSURE SERIES 1-5/16'(33,3 mm) TVFRB 1-1/16' (27,0 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NP FIGURE 7 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0K-FACTOR, 3/4 INCH NPT Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F/570C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with atorque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed on the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler filling. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 8). With reference to Figures 1, 2, and 3, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 9). With reference to Figure 2 or 3, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- arice with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers, must never be shipped or stored where their tempera- ture will exceed 100°F/380C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be re- placed. Sprinklers that have been ex- posed to corrosive products of com- bustion, but have not operated, should be replaced if they cannot be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, WRENCH RECESS (END A' USED FOR 1/2' NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4' NPT MODELS) FIGURE 8 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 9 W-TYPE 7 RECESSED SPRINKLER WRENCH annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact. sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Page 7 of B Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly - installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WA RRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Page 8 of 8 P/N 57 - XXX - X - XXX I MODEL/SIN I 1 1. 7 9 7 SPRINKL ER NATURAL BRASS WHITE POLYESTER CHROME PLATED LEAD COATED I I _L_ 135 155 175 200 286 TEMPERATURE RATING ___________ 135°F157°C 155°F/68°C 175°F/79°C 200°F/93C 286°F/141°C 330 2.8K UPRIGHT (1/2NPT) TY1131 331 2.8K PENDENT (1/2NPT) TY1231 370 5.6K UPRIGHT (1/2"NPT) 1Y3131 371 5.6K PENDENT (1/2NPT) TY3231 390 8.OK UPRIGHT (3/4NPT) 1Y4131 391 8.0K PENDENT (314"NPT) TY4231 TABLE B PART NUMBER SELECTION SERIES TV-FRB PENDENT AND UPRIGHT SPRINKLERS 4 Ordering Recessed Escutcheon: Procedure Specify: Style (specify) Recessed Es- finish), PIN .- cutcheon with (specify (specify). When placing an order, indicate the full product name. Refer to the Price List .1/2 (15 mm) for complete listing of Part Numbers. pr Plated ......... P/N 56-7Ol'-10 Contact your local distributor foc avail- 1/2',,.(15,!1rn) ' ability. / $tvje1.6. Color' Sprinkler Assemblies with NPT Coated-i P/N 56-70174-010 1/2 (15 mm). - Thread Connections: Style 20 Specify: (Specify MddellSlN), Quick Chrome Plated .........PIN 56-705-9-010 Response, (specify K-factor), (specify 25 m) tyle~ 20 temperature rating),- Serie TYFRB White Color (specify Pendent or Uprigti) Sprinkler, Coated ................ P/N 56-705-4-010 with (specify type of finish or coating), 3/4 (20 mm) PN (specify from Table B). Style 30 Chrome Plated .........P/N 56-705-9-011 • 3/4' (20 mm) Style 30 - White Color Coated ...............P/N 56-705-4-011 3/4 (20 mm) • Style 40 Chrome Plated .........P/N 56-700-9-010 3/4 (20 mm) Style 40 White Color Coated ...............P/N 56-700-4-010 Sprinkler Wrench: -. Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, - P/N 56-850-4-001.