Loading...
HomeMy WebLinkAbout2810 WHIPTAIL LOOP; ; FPC2018-0218; Permittr City of Carlsbad Print Date: 04/20/2022 Job Address: 2810 WHIPTAIL LOOP, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091202500 Track #: Valuation: $641,093.84 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: SPEC SUITE / BLDG A -SPRINKLER TI (280 HEADS) 13,784 SF SHELL TO OFFICE Permit No: FPC2018-0218 Status: Closed - Finaled Applied: 07/17/2018 Issued: 07/31/2018 Finaled Close Out: 04/20/2022 Inspector: Final Inspection: Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST POWAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 or 13R System > 100 heads $634.00 Total Fees: $634.00 Total Payments To Date: $634.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov FIRE SPRINKLER SYSTEM MATERIAL SUBMITTAL BUILDING "A" SPEC SUITE TENENT IMPROVEMENT 2810 WHIPTAIL LOOP CARLSBAD, CA 1 3iu DANIILbUN ST. POWAY, CA. 92064A 95241 PH. (B5B)513-449 Fx. (858)513-1322 f?C201-024 PIPE When you specify Allied Schedule- 10/Schedule-40 - M-COAT sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-i 0/Schedule-40 - M-COAT gives you the extra quality assurance you demand. Our Sch-i 0 (11/4"_ 8") pipe and Sch-40 (1"- 2112") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Sch-40 ASTM A135/A795 M -COAT Specifications No I Nominal I.D. Nominal Wt. ' Wt. (H2) CRR' ln;mrn mm Wall In; mm IbsIFt; kg/rn b1rkq/m 1.315 I 14& 0.133 2.05 25 33.4 26.6 3.38 . 3.05 - 14 1.660 1.380 O'N,< 2.270 2.93 32 42.1 35.1 ______ 3.39 4.36 - 1½" 1.900 1.610 ,-'.i45 20 3.61 40 48.3 40.1-' 3.68 5.37 - 2.375 0.154 3.656 5.13 1 50 60)-' 52.5 1 3.91 5.4 2½" ,ä75 2.469 0.203 5.80 7.86 "'-. 1 73 62.7 5.16 8.6 11.73 NPS Nominal Nominal I.D. I Nominal Wt. Wt. (H20 Filled) CRR Lmm O.D. In; mm In; mm I Wall In; mm Lbs/Ft; kg/rn LbsiFt; kg/m - 1¼" 1.660 1.442 0.109 1.810 2.525 7.0955 32 42.2 36.6 2.77 2.7 3.75 - 11/2" 1.900 1.682 0.109 2.09 3.04 5.6570 40 48.3 42.7 2.77 3.1 4.52 - 2.375 2.157 0.109 2.640 4.22 4.5827 50 60.3 54.8 2.77 3.9 6.28 - 2½' 2.875 2.635 0.120 3.530 5.89 3.5196 65 73 66.9 3.05 5.26 8.77 - 3.500 3.260 0.120 4.34 7.94 2.5550 75 88.9 82.8 3.05 6.4 11.82 - 4.500 4.260 0.120 5.62 11.78 1.6020 100 114.3 108.20 3.05 8.3 17.53 - 5.563 5.295 0.134 7.78 17.33 1.4874 I 6.625 I 168.3 6.357 I 161.5 0.134 I 3.40 I 9.3 I 13.8 I 23.03 I 34.27 1.0251jjj I 200 I 219 I 209.50 I 4.78 I 25.2 I I - Galvanized Pipe Schedule-10/Schedule-40 - M-COAT product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-1 23. ® Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit fire sprinkler pipe products up to 4.500" in diameter are coated with M-COAT, an advanced MIC coating that is FM approved for use in hybrid sprinkle systems. ® American made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. ® Specifications & Approvals Schedule-10/Schedule-40 - M-COAT pipe are in compliance with the following: ASTM A-i 35, Type E Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure a Customer Service (800) 882-5543 Fax: (800) 659-7730 www.afliedtube-sprinkler.com 01,7,7112'alhed 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE & CONDUIT* Harvey, It 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 A PART OF_9,! ©2013Atkore International, Inc. All Rights Reserved. STP-S4-3-1301 -,-------se _FiIrkeiiIrpIIge - Si bTei MEGA-FLOW SPECIFICATIONS NPS NOM OD NOM ID UL CRR MEGA-FLOW Schedule Schedule Schedule Mega-Flow Mega-Flow Nominal Pcs./Lift 10 40 40 wt. /ft. 11/4 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 1% 1.900 1.740 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1,961 37 2% 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19- 4 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 .75 1.00 8.000 10 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZ','. The CRR is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 7.0). MEGA-THREAD SPECIFICATIONS NPS NOM OD NOM ID UL CRR MEGA-THREAD "Schedule Schedule Mega-Thread 40 Mega-Thread 40 L.W.T. Pipe Nominal wt./ft. 1 Pcs./Luft 1 1.315 1.087 1.049 1.00 1.00 .61 1.462 70 1% 1.660 1.416 1.380 1.00 1.00 .39 1.989 51 1'/z 1.900 1.650 1.610 1,00 1.00 .31 2.370 44 2 2.375 2.117 2.067 1.00 1.00 .25 3.094 30 Calculated using Standard UL CRP formula, UL Fire Protection Directory, Category VIZY. The CRR is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 7.0). @ C & A P PR 0 VED FM Approved and Fully Listed Sprinkler Pipe Wheatland's Mega-Flow steel fire sprinkler pipe is FM Approved for roll-grooved, plain-end and welded joints for wet systems; and UL, C-UL and FM Listed for use with roll-grooved, plain- end couplings and welded joints for wet, dry preaction and deluge systems. Mega-Thread is FM Approved for use in wet systems and is UL, C-UL and FM Listed for wet, dry and preaction sprinkler systems. Approvals and Specifications Both products meet or exceed these standards: ASTM A795, Type E, Grade A NFPA 13 and NFPA 14 Mega-Thread is approved for standard hanger spacing Manufacturing Protocols Mega-Flow and Mega-Thread are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings Mega-Flow black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Mega-Thread is hot-dip galvanized to meet FM requirements for dry systems and is safer to weld than many zinc-coated, light-wall threadable products. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. 1thi9b UYAL PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: LI MEGA-FLOW-BLACK [I] MEGA-THREAD-HOT-DIP GALVANIZED WF) t ®@ Tube A DIVISION OFZEKELMAN INDUSTRIES FITTINGS Ductile Iron Threaded Fittings / 1 c -Caw. SMITH..,COOPER7 INTERNATIONAL Ductile Iron Threaded Fittings Specifications 0 branded ductile iron threaded fittings are UL Listed and FM AjDroved at 500 psi Rated to 300 WSP cULus Ductile iron castings conform to ASTM A536 LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs confDrm to ASME B16.14 < FM> Fittings are 100% air tested APPROVED NFl threads on all fittings conform to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nnshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 ______ 480 250 - 460 - 300 440 350 420 400 400 450 380 360 500 550 340 600 320 650 300 C(DUS <~> APPROVED LISTED Fig. 35E 3_900 Elbow Size in Part Number A in - Packing Weight lb Inner Master 1/2 35E 3004 1.13 1.31 100 70 200 140 0.2 0.3 3/4 1 - 1-1/4 35E 3006 - 35E 3010 35E 3012 1.50 40 - 80 1- 50 0.5 1 0.8 1.75 1 - 25 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 I!! Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1x1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x 1 35RE3014010 1.65 1.80 - 20 40 0.8 1-112x 1-114 35RE3014012 1.82 - 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 36 1.0 2x1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 2.16 10 20 1.5 2-1/2x1-1/2 35RE3024014 1 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 1 2.39 2.60 6 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3 0.98 80 160 0.3 1 35F3010 1.13 40 80 0.5 1-1/4 35F 3012 35F3014 35F 3020 1.29 25 -50 0.7 - 1-1/2 2 1.44 1.69 20 10 40 - 1.0 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3513004 351 3006 1.13 80 160 0.3 3/4 1.31 30 60 0.5 1 1-1/4 1-1/2 2 35T 3010 3513012 3513014 351 3020 1.50 1.75 1.94 -2.25 25 50 0.7 10 20 1.1 1.5 -- 2.4 10 20 6 12 2-1/2 351 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 • www.smithcooper.com ®s <E> APPROVED LISTED Fig. 35RT3 - Reducing Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1/2 1x1/2 1x1/2x1 1 x3/4 35R13006004 35RT3010004 35RT3010004010 35RT3010006 1.20 1.26 1.20 1.26 1.22 1.36 60 30 30 25 120 60 60 50 0.4 0.6 0.6 0.6 1.50 1.38 1.36 1.50 1.38 1.45 1 x3/4x3/4 - 1x3/4x1 1-1/4x 1/2 I-1/4x1/2x1-1/4 1-1/4x3/4 1-1/4 x3/4x 1-1/4 1-1/4x1 - 1-1/4xlxl/2 35RT3010006006 1.38 1.31 1.45 35 70 0.6 35RT3010006010 1.50 1.45 1.50 25 20 50 0.7 0.8 35R13012004 1.34 1.34 1.53 40 35RT3012004012 1.75 1.53 1.75 25 15 20 50 30 40 0.9 0.9 1.0 35RT3012006 35R13012006012 35RT3012010 1.45 1.45 1.62 1.75 1.75 1.62 1.58 1.58 1.67 15 30 40 40 1.0 35RT3012010004 1.34 1.26 1.53 25 500.7 1-1/4x1x3/4 1-1/4 xlxl 35RT3012010006 35RT3012010010 1.45 1.38 1.63 20 0.8 1.58 1.50 1.69 20 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 TO 1-1/2x1/2x1-1/4 35R13014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x 112x1-112 35R13014004014 1.94 1.66 1.94 12 24 1.2 I-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x3/4x1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x314x 1-1/2 1-1/2x1 1-1/2x1x1/2 1-1/2x1x3/4 1-1/2x1x1 1-1/2x1x1-1/4 35RT3014006014 1.94 1.75 1.94 18 36 1.2 35R13014010 1.65 1.65 1.80 12 20 16 24 40 1.2 0.8 0.9 1.0 1.2 35R13014010004 1.44 1.25 1.69 35RT3014010006 35R13014010010 1.50 1.44 1.75 32 32 24 1.65 1.82 1.50 1.80 16 35RT3014010012 1.67 1.88 12 1-1/2xlx1-1/2 1-1/2x1-1/4 1-1/2x1-1/4x1/2 1-1/2x1-1/4x3/4 35RT3014010014 1.94 1.80 1.94 1.88 12 12 24 24 1.3 1.4 0.9 1.0 35R13014012 1.82 1.82 35RT3014012004 1.41 1.34 1.66 1.75 16 32 32 35RT3014012006 1.52 1.45 16 1-1/2x1-1/4x1 1-1/2x1-1/4x1-1/4 35RT3014012010 1.65 1.58 1.80 16 14 32 28 1.1 1.3 35RT3014012012 1.82 1.75 1.88 1-1/2x1-1/4x1-1/2 2x 1/2 2x314 2x1 2 x 1 x2 ?xl-1/4 35RT3014012014 1.94 1.88 1.94 14 16 10 8 8 8 28 20 20 16 16 16 16 16 20 20 16 16 16 1.4 35R13020004 -- 1.49 1.49 1.88 1.5 1.6 1.7 1.9 1.9 2.0 2.1 1.3 1.4 1.5 1.7 1.8 35R13020006 1.60 1.60 1.97 35RT3020010 35RT3020010020 35RT3020012 1.73 2.25 1.90 1.73 2.02 1.90 2.02 2.25 2.10 2x 1-1!4x2 2x1-1/2 2x1-1/2x1/2 2x1-1/2x314 2x1-1/2x1 2x1-1/2x1-1/4 35R13020012020 2.25 2.10 2.25 8 35RT3020014 35R13020014004 35RT3020014006 2.02 1.49 2.02 1.41 ?.16 1.88 8 10 10 1.60 1.52 1.97 35R13020014010 1.73 1.65 2.02 8 8 35RT3020014012 1.90 1.82 2.10 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 _8_ Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 1 x 1-1/4 1 x 1-1/2 1-1/4xlxl-1/2 1-1/4x1-1/2 1-1/4x2 1-1/2x1-1/4x2 1-1/2x2 35BT3006010 1.45 1.45 1.37 1.58 1.65 1.82 1.82 1.90 2.02 30 20 15 15 15 10 10 8 60 40 30 30 30 20 20 16 0.6 0.9 1.0 1.2 1.3 1.6 1.8 1.8 35BT3010012 1.67 1.67 1.80 35BT3010014 1.80 358T3012010014 35BT3012014 35 T3012020 35B13014012020 1.88 1.88 2.10 2.16 1.80 1.88 2.10 2.10 35BT3014020 2.16 2.16 2.02 I D SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 9 wwwsmithcooper.com 112 COUS APPROVED Fig. 35CP3 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 35CP3004 1.38 200 400 0.1 3/4 163 00 200 02 1 35CP3010 60 120 0.4 1-1/4 35CP3012 2.00 25 70 0.5 0.7 1-1/2 350P3014 2.19 2 35CP3020 2.62 15 30 3.00 2-1/2 350P3024 9 18 2.2 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35R03010004 1.69 80 160 0.3 lx 3/4 35R03010006 1.69 60 170 1-1/4x3/4 35RC3012006 2.06 40 80 0.6 2x1(not hex)l 35R03020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size I in Part Number A in Packing Weight lb Inner Master 11 x 1/2 35HB3010004 35HB3010006 3 j 1.06 180 180 90 360 360 180 0.2 0.1-- 0.2 - 150 _i 1-1/ x 1 1-1/2 1.06 1.19 35H83014010 75 1-1/2x1-1/4 2 x 1 2x1-1/4 2x1-1/2 35HB3014012 35HB3020010 35HB3020012 35HB3020014 1.25 40 150 0.3 0.6 0.6 0.6 1.38 1.38 1.38 40 40 - 80 1 80 Fig. 35SP3 -Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 200 0.3 1.37 100 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 _1 T0 45 90 0.6 Fig. 35U 3- Union with Brass Seat Size in P t N b ar um er A in Packing Weight lb Inner Master 1 1-1/4 1-1/2 2 35U 3010 2.19 2.50 2.62 20 40 30 20 12 1.0 1.2 1.7 2.4 35U 3012 35U 3014 15 10 6 35U 3020 3.12 113 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com C&US <~> APPROVED LISTED Size Part Number J A in Packing Weight lb Inner [ Master 1 43010 1.50 20 40 0.9 1-1/4 35X 30 1.75 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Fig. 3513- Cross Fig. 35R13 - Reducing Cross Size Part Number A in B in Packing Weight lb Inner Master 1-1/4x 1 1-1/2x1 35R 35RX3014010 1.67 1.8 1.58 5 1.73 15 12 30 1.2 24 1.4 2 x 1 35RX3020010 2.02 16 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner I Master 1/2 3/4 - 1 1-1/4 1-1/2 - 35C 3004 - 350 3006 - 35C3010 3503012 35C3014 35C 3020 35C3024 0.87 0.97 1.16 1.28 1.33 300 200 110 70 50 25 18 600 - 400 - 220 - 140 0.1 0.1 0.2 0.4 0.5 100 2 2-1/2 1.45 1.70 50 0.8 36 1.6 Fig. 35BC3 - Beam Clamp B B Jj --Z-!,e in Part Number A in Packing Weight I lb Inner I Master 3/8 1/2 35B03003 35603004 0.75 100 1 200 160 0.3 0.5 SMITH-COOPER IN'I'ERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwwsmithcoopet.com 114 SPRINKLER HEADS tqcv? Fire Protection Products Worldwide Contacts I www.tyco-fire.com Model ESFR-25 252 K-factor Pendent Sprinkler Early Suppression, Fast Response General Description TYCO Model ESFR-25 Pendent Sprin- klers are Early Suppression, Fast Response (ESFR) sprinklers having a nominal K-factor of 25.2 (Ref. Figure 1). They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-25 Sprinklers are pri- marily used for ceiling-only sprinkler protection of (but not limited to) the fol- lowing storage applications: most encapsulated or non-encap- sulated common materials including cartoned, unexpanded plastics uncartoned (exposed) expanded plastics in accordance with NFPA 13 and FM Global standards some storage arrangements of rub- ber tires, roll paper, flammable liq- uids, aerosols, and automotive components For more specific criteria, refer to Table A as well as the applicable design standard. The Model ESFR-25 Pendent Sprin- klers provide the system designer with hydraulic and sprinkler place- ment options not presently available to the traditional ESFR sprinklers having nominal K-factors of 14.0 and 16.8. In particular, the Model ESFR-25 Sprin- kler has been designed to operate at substantially lower-end head pres- sures, as compared to ESFR Sprinklers IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 having nominal K-factors of 14.0 and 16.8. This feature offers flexibility when sizing system piping, as well as possi- bly reducing or eliminating the need for a system fire pump. Also, Model ESFR-25 Sprinklers permit use of a maximum deflector-to-ceiling distance of 18 inches (460 mm) versus 14 inches (356 mm). Additionally, a storage arrangement of 40 ft. (12,2 m) with a ceiling height of 45 ft. (13,7 m) does not require in-rack sprinklers as do other ESFR Sprinklers having nominal K-factors of 14.0 and 16.8. The Model ESFR-25 Sprinklers are listed by Underwriters Laboratories (UL) for specific applications with a maximum storage height of 43 ft. (13,1 m) with a maximum ceiling height of 48 ft. (14,6 m) without the requirement for in-rack sprinklers. Refer to the Specific Application Listing (UL) for the design criteria. Applications for the TYCO ESFR Sprin- klers are expanding beyond currently recognized installation standards. For information on research fire tests (e.g., with flammable liquids and aerosols) that may be acceptable to an author- ity having jurisdiction, contact Tyco Fire Protection Products (TFPP) Technical Services. If.h1D The Model ESFR-25 Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any authorities having jurisdiction (e.g., FM Global). Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. In all cases, the appropriate NFPA or FM Global installation standard, or other applicable standard, must be referenced to ensure applicability and to obtain complete installation guide- JULY 2016 lines. The general guidelines in this data sheet are not intended to provide complete installation criteria. Sprinkler Identification Number (SIN) TY9226 1Y9226 is a re-designation for Central SIN 9226, Gem SIN G8441, and Star SIN S8010. Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved NYC Approved under MEA 356-01-F LPCB Certified (Cert. Nos. 094b and 0071) CE Certified (Certificate of Conformity 1725-CPD-H0010) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connections 1 Inch NPTor ISO 7-R 1 Discharge Coefficient K=25.2 gpm/psi½ (362,9 1pm/bar½) Temperature Ratings 165°F (74°C) and 212°F (100°C) Finish Natural Brass TFP3I2 TFP3I2 Page 2 of 4 1 7 ___ 1"NPT f Components: 8 / 1-13/16" / 9/16 (46,0 mm) 1 - Frame / . (14,3 mm) 2 - Deflector 9 ' NOMINAL 3 - Compression MAKE-IN Screw 4-Hook 6 5 - Strut 3-13/16 6 - Link Assembly 5 (96,8 mm) THERMAL 7 - Button I SENSING 8 - Sealing I ELEMENT Assembly 4 9 - Ejection Spring - WRENCH FLATS 2 TEMPERATURE RATING - 2" (50,8 mm) -H FIGURE 1 MODEL ESFR-25 PENDENT SPRINKLER, 25.2K EARLY SUPPRESSION, FAST RESPONSE Storage Type NFPA FM Global Open Frame (i.e., no solid shelves) Refer to NFPA 13 Refer to FM Global Single, Double, Multiple-Row, or Portable Rack Storage of Chapters 16 and 17 2-0 and 8-9 Class -IV and Group A or B Plastics Solid Pile or Palletized Storage of Refer to NFPA 13 Refer to FM Global Class l-IV and Group A or B Plastics Chapters 14 and 15 2-0 and 8-9 Idle Pallet Storage Refer to NFPA 13 Chapter 12 Refer to FM Global 2-0,8-9, and 8-24 Rubber Tire Storage Refer to NFPA 13 Chapter 18 Refer to FM Global 2-0 and 8-3 Roll Paper Storage Refer to NFPA 13 Refer to FM Global 8-21 (Refer to the Standard) Chapter 19 Flammable/Ignitable Liquid Storage Refer to NFPA 30 Refer to FM Global 7-29 (Refer to the Standard) Aerosol Storage (Refer to the Standard) Refer to NFPA 30B Refer to FM Global 7-31 Automotive Components in Portable Racks Refer to NFPA 13 N/A (Control mode only; refer to the Standard) Chapter 20 N/A - Not Applicable TABLE A MODEL ESFR-25 PENDENT SPRINKLER COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW TFP3I2 Page 3 of 4 Physical Characteristics Frame .............................Brass Deflector ..........................Bronze Compression Screw ..........Stainless Steel Hook ............................MONEL Strut.............................MONEL Link Assembly................Solder, Nickel Button .............................Brass Sealing Assembly. Beryllium Nickel w/TEFLON Ejection Spring ..................INCONEL Operation The fusible link assembly is com- prised of two link halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, activating the sprinkler and flowing water. Design Criteria The following general guidelines pro- vided for the TYCO Model ESFR-25 Pendent Sprinklers can be used for a quick reference. The National Fire Protection Associa- tion (NFPA) and FM Global (FM Approv- als) provide installation standards that must be used to properly design an automatic sprinkler system utilizing Early Suppression, Fast Response (ESFR) Sprinklers. The guidelines pro- vided by NFPA and FM Global may differ. Consequently, the appropri- ate standard must be used for a given installation. In all cases, the appropriate NFPA or FM Global installation standard must be referenced to ensure applicabil- ity and to obtain complete installation guidelines. The following general guidelines are not intended to provide complete installa- tion criteria. In addition to this technical data sheet, the following data sheets describe other TYCO ESFR Sprinklers: TFP315 Model ESFR-17 (TY7226) K=16.8 Pendent Sprinkler TFP316 Model ESFR-17 (TY7126) K=16.8 Upright Sprinkler TFP317 Model ESFR-17 (TY7223) K=16.8 Pendent Sprinkler TFP318 Model ESFR-1 (TY6226) K=14.0 Pendent Sprinkler TFP319 Model ESFR-14 (TY6236) K=14.0 Pendent Sprinkler System Type Wet Pipe Roof Construction Unobstructed or obstructed con- struction (e.g., smooth ceiling, bar joists, beam and girder, and so forth). Where the depths of the solid struc- tural members (e.g., beams and stem) exceed 12 inches (302 mm), install ESFR Sprinklers in each channel formed by the structural members. Ceiling Slope Maximum 2 inch rise for 12 inch run (16.7%) Maximum Coverage Area 100 ft2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Coverage Area 64 ft2 (5,8 m2) per NFPA 13 / FM Global 2-0 Maximum Spacing 12 feet (3,7 m) for building heights up to 30 feet (9,1 m) 10 feet (3,1 m) for building heights greater than 30 feet (9,1 m). In some cases, installation standards permit a greater spacing. Minimum Spacing 8 feet (2,4 m) Minimum Clearance to Commodity 36 inches (914 mm) NFPA Deflector-to-Ceiling Distance 6 to 18 inches (152 to 457 mm) FM Global Centerline of Thermal Sensing Element-to-Ceiling Distance Refer to FM Global 2-0 for Storage Sprinklers. Specific Application Listing (UL) TYCO Model ESFR-25 Pendent Sprin- klers are listed by Underwriters Labo- ratories (UL) for Specific Applications with a ceiling height greater than 45 ft. (13,7 m) up to and includ- ing 48 ft. (14,6 m), and a storage arrangement up to and including 43 ft. (13,1 m), the following guide- line are provided for the TYCO Model ESFR-25 Pendent Sprinklers: Sprinkler Position Pendent: Frame arms aligned with pipe Deflectors parallel with ceiling or roof System Type Wet Pipe only Maximum Area of Coverage 100 ft2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Area of Coverage 64 ft2 (5,8 m2) according to NFPA 13 Maximum Slope Ceiling 2 inch rise for 12 inch run (16.7%) Maximum Spacing 10 feet (3,1 m) In some cases, the installation stan- dards permit a greater spacing. Minimum Spacing 8 feet (2,4 m) Temperature Rating 165°F (74°C) and 212°F (100°C) Deflector Distance from Walls Minimum of 4 inches (102 mm) from walls but no more than 1/2 the allow- able distance permitted between sprinklers Deflector to Top of Storage Minimum of 36 inches (914 mm) Deflector-to-Ceiling Distance 6 to 14 inches (152 to 356 mm) Maximum Ceiling Height 48 feet (14,6 m) Maximum Storage Height 43 feet (13,1 m) Storage Arrangement Palletized, solid piled, open frame, single row, or double row Commodity Class I-IV; Cartoned, unexpanded plastic Sprinkler System Design NFPA 13 for ESFR Sprinklers based upon 45 psi (3,1 bar) design pressure, 169 gpm (640 1pm) with 12 sprinkler remote area Minimum Aisle Width 5 feet (1,5 m) TFP3I2 Page 4 of 4 FITTING SIDE TOWARDS SPRINKLER FITTING WRE REC FIGURE 2 W-TYPE 1 SPRINKLER WRENCH Installation TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Damage to the fusible Link Assem- bly during installation can be avoided by handling the sprinkler by the frame arms only (i.e., do not apply pressure to the fusible Link Assembly), and by using the appropriate sprinkler wrench. Failure to do so can lead to an unstable link assembly and premature activation of the sprinkler. Damaged sprinklers must be replaced. A leak-tight 1 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 20 to 30 lbs.-ft. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Note: Install the Mode! ESFR-25 Pendent Sprinkler in the pendent posi- tion (Ref. Figure 2). Step 1. With pipe thread sealant applied, hand-tighten the sprinkler into the sprinkler fitting. Do not apply pres- sure to the Link Assembly, and handle the Model ESFR-25 Pendent Sprinkler only by the Frame arms. Step 2. Wrench-tighten the Model ESFR-25 Pendent Sprinkler using only the W-Type 1 Sprinkler Wrench (Ref. Figure 2) and by fully engaging (seating) the wrench on the sprinkler wrench flats (Ref. Figure 1). Step 4. After installation, inspect the Link Assembly of each Model ESFR-25 Pendent Sprinkler for damage. In par- ticular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assem- bly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. Care and Maintenance TYCO Model ESFR-25 Early Suppres- sion, Fast Response 25.2K Pendent Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Model ESFR-25 Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226), (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) ..................58-441-1-165 212°F (100°c) .................58-441-1-214 Special Order Sprinkler Assemblies with ISO 7-1 Thread Connection Specify: Model ESFR-25, Early Sup- pression, Fast Response 25.2K Pendent Sprinklers (TY9226) with ISO 7-1 thread connection, (specify temperature rating), with Natural Brass finish, P/N (specify): 165°F (74°C) .................. 58-442-1 -165 212°F (100°C) .................58-442-1-214 Sprinkler Wrench Specify: W-Type 1 Sprinkler Wrench, P/N 56-872-1-025 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. tqco MONEL and INCONEL are trademark of Special Metals Corporation. Fire Protection Products TEFLON is trademark of DuPont Corporation. QUICK RESPONSE UPRIGHT CONVENTIONAL J QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL N 0000 MMI "am FIRE SPRINKLER CORPORATION QUICK RESPONSE A U TO MA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze -.Deflector -brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size 0 SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER CLASSIFICATION BULB COLOR I N.F.P.A. MAXIMUM I I I TEMPERATURES I CEILING TEMPERATURE ORDINARY 135F/155°F 57C/68°C I ORANGE/RED 100°F 38'C INTERMEDIATE 175°F/200°F 79'C193°C I YELLOW/GREEN 150°F 66°C I HIGH 286°F 141°C BLUE 225°F 107°C APR 2017 GFS-100a (Formerly A-20) QUICK RESPONSE A U TO MA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome White Pcyester3 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester2'3 8.0 (115 metric) I 3/4"NPT (20mm) 2 7/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 29/16'. °FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD cULus FM LPC CE NYC-DOB MEA 101-92-E 135°F - 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X -- -- -- X GL4215 4.2 LH X X X X X X --- -- --- X VPRIGH GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0* LH/OH X X X X X X -- -- -- X 3L811 H/QH) x 0 1 x 0 1 x x x x x x GL2801 2.8 LH X X X X X X -- -- -- X GL4201 4.2 LH X X X X X X -- -- --- X PENDEND GL5601 5.6 LH/OH X X X X X X X X X X GL8101 8.0° LH/OH X X X X X X -- -- --- X ED QK5 X ® X 0 X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALLt GL8133 8.0 LH X X X X X X - - -- GL2826 2.8 LH X X X X X X - --X NTA HORIZONTAL GL4226 4.2 LH X X X X X X - - - X SIDE GL5626 5.6 LH/OH X X X X X X X X GL5627a 5.6 LH/OH X X X X X -- --- X X GL8127 8.0 LH/OH X X X X X X --- -- -- -- CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X (OLD STYLE) GL8125 8.0 LH/OH X X X X X -- -- X X --- 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NEPAl 3 AND ANY OTHER RELATED DOCUMENTS. §1-IORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. aINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD *1/2"NPT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity . Model Number . Style Orifice products found to be defective in material or workmanship for a Thread Size • Temperature • Finishes desired period of one year from date of shipment. Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com FIRE SPRINKLER CORPORATION APR 2017 PRINTED U.S.A. GFS-lOoa (Formerly A-20) HANGER & BRACES COMPONENTS l_ ) 1( tt) Thj GST 100 1/4x1" 210 (7/16"OSB) 25 125 670 (3/4" Ply) GST 200 1/4x2 1760 (Fir) - 25 125 GST 300 114x3 2060 (Fir) - 25 125 GST .75 1/4x3/4" 564 (3/4" Ply) - - 25 125 GST 10 1/4x1" 300 25 125 GST 20 1/402" 1760 (Fir) 850 1475 25 125 GST 20-SS 1/4x2" 1760 (Fir) 850 - 25 125 GST 25-380 3/8x2.1/2" 2113 (Fir) 1500 25 125 GST 30 1/403" - 2060 (Fir) 1 500 -. - 1475 25 125 : #14 Black GST3OSS 1/4x3" 2060 (Fir) - . - -- 25 125 Nut Driver Part #8113910 GST40 1/4x4 2180 (Fir) 25 125 GST 60 1/4 x6" 2230 (Fir) 25 125 - GST2 114x2" 1760 (Fir) 25 125 GST 2.5-380 3/8x2.1/2" 2113 (Fir) 25 125 GST3 1/4x3" 2275 (Fir) . 25 125 GST4 1/4x4 2180 (Fir) 25 125 GST 6 1/406" 2230 (Fir) . -- - - 25 125 #14 SW Red Nut Driver Part # 8114910 ------ 1/4" 8002957 1/4" 8003957 1/4' 8004957 3/8" 8006957 3/8" 8007957 3/8" 8008957 3/8" 8068925 3/8" 8009925 3/ 8010957 3/8" 8069925 3/8" 8011925 3/8' 8012925 1/2" 8013925 1/2" 8014925 1/2" 8015925 1/2" 8016925 1/2 8017925 WL El 51 Not less than "---FL- 2' nominal .,., - - Product Features 11.112') - - .--. --- _______ - "No pre-drilling required. usingNot less than Quick to install mm 3"nominal Nut Driver with an 18V cordless thickness (2-11T) (depth or side Wood Joist drill/driver. of vertical member) - . • . - 7' Saves time from traditional Double 5heefrock - methods. Ceiling - e l • Reduces installation cost if 'FiF' , I I •Made in the U.S.A. El Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. "Accommodates up to 3 /2" x 12 pitch roof. • Reduces installation cost Allows 17" deflection from vertical. • Made in the U.S.A. 7 . IREW tinnrn iii im I !ll9OL) UD) i 3/8' 8139957 SH.GST 20 114 x2 1257 (Fir) 1050 1475 25 125 125 3/8" 8141957 SH.GST30 1/4x3 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com 4_9'~ Q I _________ V Q e wv A Not lass than 2' nominal vdth / Product Features (1-1/2') up to 3-1/2' pipe; not less than No pre-drilling required. 3' (2.1/2') nominal width 4 & 5' pipe Floor Joist Quick to install using the Sammy Minimum 2-1/2' from bottom for Nut Driver with an 18V cordless branch lines. Minimum 3' from bottom for main foes. Exception: This drill/driver. requirement shall not app to 2' or thicker nailing stops resting on top of /1 Saves time from traditional steel beams. methods. Reduces installation cost. Made n the USA n - 1/4" 8018957 1/4" 8019957 3/8' 8020957 - - , 3/8' 8021957 4 3J" 8673K5 #14 SW Red 3/8" 8022925 Nut Driver 3/8' 8023925 Part #8114910 - - __ - fD t!1fflilE19 IiO 9J SWG 100 1!4 xl' 622 (Fir) 25 125 SWG 200 1/4 x 2" 1725 (Fir) 25 125 - SWG 10 114x1" -. 622 (Fir) 300 25 125 SWG 20 1/402" 1725 (Fir) 1050 25 125 SWG 20 SS 1/402 1725 (Fir) 850 25 125 SWG 25-380 3/80 2-1/2" 2249 (Fir) 1500 25 125 SWG 30 1/4o 3" 1884 (Fir) 25 125 - 1NI8TALt*tI0NSTEPS - ITALtATb0N;8T8 M!Thf1b IF(TQ.WOOD .& $TELj Insert the appropriate nut driver into a 3/8" or 112" portable drill Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Dull should be in a vertical position. Push the face of the nut driver tight to the member When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8' 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Insert the appropriate nut driver info a 3/8" or 112" portable drilL Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlln steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver conies into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Per NFPA 1' :? 1-3/8"0r1/2" Lag Bolts I Up to 4" (100mm) pipe 2- #16 x 2" Drive Screws 1/2" (15mm) - 4(100m m) pipe 2 UL Listed Fastener Table Pipe Size Qty Fastener Type Material 2" 2 #16 x 2" Drive screws Wood 2" 1 /8" Lag bolt Wood 21/2" - 4" 1 1/2" Lag bolt Wood 31/2" 2 1/4" x 11/2" Lag bolts Wood 4" 2 1/4" x 2" Lag bolts ** Wood 4" 2 1/4" x 1" Tek screws Metal (15 gauge) 4" 2 1/4" x 1" Tek screws Metal (16 gauge) ** No pre-drilling Up Upper Attachments Fig. 58 - Threaded Side Beam Bracket ®TDLCO' Size Range: /8'-16 rod, pipe sizes 1/2" (15mm) thru 4" (100mm) Material: Pre-Galvanized Steel Function: Practical and economical bracket used to support piping from wood, concrete or steel beams. Features: Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept /8' and 1/2" fastener bolts. Per NFPA 13: 1/2" (15mm) thru 2" (50mm) pipe requires /8" fastener, 21/2" (65mm) thru 4 1100mm) pipe requires /2" fastener.* Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4)100mm) pipe. Finish: Pre-Galvanized Order By: Figure number and finish *Note: Additionally UL has listed the Fig. 58 with fasteners as shown in table below. 2- 11C x 2" Lag Bolts (No Pre-Drilling Up to 4(100mm) pipe 2- #14x 1" Tek Type Screws Larger pipe sizes can be hung with reduced spacing Part No. Pipe Size Rod A B C Approx. Wt/100 in. (mm) Size in. (mm) in. (mm) in. (mm) Lbs. (kg) 58 1/2" - 4" 115.1001 /8"-16 2/4" 169.81 11/2" (38.1) 11/8" (28.6) 14 (6.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 85 B-Line by 13 *Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B32051 - Threaded Rod (right & left hand threads) Size Range: /'-16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish ®TOLCO T TL 4Specif~yth TL re Size 000 Standard Design Load Thread Size Thread Length TL 650°F (343°C) 150°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-318 X /8'-16 21/2' (63.5) 730 13.251 572 (2.54) B3205-1I2 X '1' h/2'_13 21/2' (63.5) 1350 16.001 1057 (4.70) B3205-5/ox ,L /8°-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x '1' /4'-10 3' (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x 7/'•9 31/2' (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. II ATR - All Threaded Rod - 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length Size Range: 3/8 -16 thru 11/2'6 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F 399°Cl Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Part No. - Size x Length Threads Recommended Load Approx. Wt./100 Ft. AIR Fig. 99 Per Inch Lbs. (kN) Lbs. (kg) AIR /4" x 120 99-1I4" x length 20 240 (1.07) 12 15.441 AIR 3/g" x 120 99-/8" x length 16 730 (3.24) 29 (13.15) AIR 1/2" x 120 99-1/2" x length 13 1350 16.001 53 (24.04) AIR 5/6' x 120 995/" x length 11 2160 (9.60) 89 (40.37) AIR 3/4" x 120 993/4" x length 10 3230 (14.37) 123 (55.79) AIR hg" x 120 991/8" x length 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. B-Line by llir.IU All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Revised 4/28/2014 94 Fire Protection Solutions Fig. 200S Fig. 20021/2 to 200-8 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pie-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. / (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in ,f-hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F )343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of Fig. 200C Fig. 200F Pipe Size Rod Size A B Approx. Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200_1/2 1/2" (15) /8"-16 31/8" 119.41 2/8' (66.7) 11 (5.0) 200-I4 3/4" (20) /t'-16 31/8' 179.41 21/2" (63.5) 11 (5.0) 200-1 1" (25) /811-16 3/8' (85.7) 2/8' (66.7) 12 (5.5) 200-11I4 11/4' (32) /811-16 33/4' (94.0) 2/8" (13.0) 13 (5.9) 200-11I2 11/2" 1401 /8"-16 3 /8" (98.4) 2/8" (13.0) 14 (6.4) 200-2 (50) /8"-16 41/2" (114.3) (76.3) 15 (6.9) 200-21I2 21/2" (65) /8"-16 55/' (142.9) 41/8" (104.1) 21 112.31 200-3 3" (75) /8'-16 5/8" (149.1) 4" (101.6) 29 (13.3) 200-31I2 31/2" (90) /8"-16 7fe" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /811-16 7/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"_13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"_13 101/8" (251.2) 6/4' (171.4) 73 (33.4) 200-8 8" (200) 1/2"13 131/8" (333.4) 8/4" (222.2) 136 (62.3) Fig. 200 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 B-Line by 743