HomeMy WebLinkAbout7740 EL CAMINO REAL; ; FS050015; PermitCity of Carlsbad
Fixed Systems Permit
Permit No: FS050015
7740 EL CAM INO
Job Address:
REAL
Permit Type: FIXSYS
Parcel No:
Status: APPROVED
Applied 9/22/2005
Approved: 9/29/2005
Reference No.: Issued: 9/29/2005
Inspector:
Project Title: RED DAHLIA HOOD & DUCT PLAN CHECK & INSPECTIONS
Applicant: Owner:
Fees ($) Add'l Fees ($) Total ($) Balance ($)
120 0 120 0
4-
CITY OF CARLSBAD
FIRE DEPARTMENT
APPROVED
Subject to field inspection and required
tests, notations hereon, cendEtions in
correspondence and conformance with
applicable regulations. The stamping
Of thes Ian all not be held to permit
or ap v violation of any law
By Date1/1ZJ
ØO O( b3/O
INTERSTATE FIRE PROTECTION SYSTEM DETAIL
ITEM DESCRIPTION SIZE DETAILS IDIMENSIONS NOZZLES QTY FLOW
HOOD 10'x6'
I MEREX KP3.75 X 2 375 GAL 11 MAX
2 DUCT NOZZLE 12" X 18" 0" PER/ 82" MAX 16416 2
-
2
3 PLENUM NOZZLE 10' SINGLE-BANK 11982 1 1
4 GAS RAIDIANT CHAR BROILER 24" X 24" 11982 1 1
5 RANGE NOZZLE %" X 24" VITH BACK SHELF 11982 3 3
6 DEEP FRYER NOZZLE 15" X 19" 13729 1 2
7 GRIDDLE NOZZLE 24" X 24" 11982 1 .1
8 SALAMANDER 30" X 12" 11982 1 1
9
9
10 LIQUID TIGHT SEAL UL RATED 6
TOTAL FLOW PTS. USED 10 11
12 LINK DETECTOR I50de..
13 PULL STATION 18" OFF FLOOR I
14 GAS SHUT OFF VALVE 1.5" MCHANICAL I
15 FIRE EXTINGUISHER K-MODEL I
16 IFIRE EXTINGUISHER A:10BC I
RED DAHLIA
11
l -n
-
m Cl)
°rn
I—
z
Cl)
BEVERAGE
STATION
FRONT SERVICE
COUNTER
PA
r_
[M1 N\1 l/l fl
- 7
SYSTEM INSTALLED TO NFPA 17A, 96 AND THE
MANUFACTURES LISTED INSTALLATION MANUAL
ALL FUEL SOURCES WILL SHUTDOWN UPON HANGERS SHALL BE 0 MINERALACS ACTIVATION. SUPPLY LINE 12' SCH. 4° EXPOSED PIPE SHALL BE CHROME PLATED. SYSTEM WILL TIE INTO ALARM SYSTEM IF ONE BRANCH LINE 3/8' SCH. 40 PIPING SHALL BE RIGIDLY SUPPORTED TO
EXISTS. SCALE:1\2' = V PREVENT MOVEMENT.
JOB SITE
RED DAHLIA
7740 EL CAMINO REAL STE.F
CARLSBAD, CA
SHAWN 760 580-3549
HOOD AND DUCT
AMEREX KIP
FIRE SUPPRESSION SYSTEM
HOOD DETAIL
INTERSTATE FIRE PROTECTION
36140 JANA LANE
WILDOMAR, CA 92595
(800) 282-9229 FAX (951) 461-6980
Design / install/ employee
Steve Nauert Lic. C16-747953
0 tY31SX 1
it F
I FP LA'(ZO
13,1 ?-q
2-1:*p 9 L.~
T
viz )Y If
I re
3Ff' 3"4
SYSTEM INSTALLED TO NFPA 17A, 96 AND THE
MANUFACTURES LISTED INSTALLATION MANUAL
ALL FUEL SOURCES WILL SHUTDOWN UPON
HANGERS SHALL BE 0 MINERALACS ACTIVATION. SUPPLY LINE 1\2' SCH. EXPOSED PIPE SHALL BE CHROME PLATED. SYSTEM WILL TIE INTO ALARM SYSTEM IF ONE BRANCH LINE 3/80 SCH. 40 PIPING SHALL BE RIGIDLY SUPPORTED TO EXISTS. SCALE:1\2' = V PREVENT MOVEMENT.
JOB SITE
RED DAHLIA
7740 EL CAMINO 'REAL STE.F
CARLSBAD, CA
SHAWN 760 580-3549
HOOD AND DUCT
AMEREX KP
FIRE SUPPRESSION SYSTEM
ISOMETRIC PIPE DETAIL
INTERSTATE FIRE PROTECTION
36140 JANA LANE
WILDOMAR, CA 92595
(800) 282-9229 FAX (951) 461-6980
Design / install! employee
Steve Nauert Lic. C16-747953
C3
Fire Department Notes
When a fire alarm system is provided in the building, it shall be interconnected to
the fire extinguishing system per 1998 NFPA hA. Section 3-2.1.5.
All gas fueled, electrically powered and heat-producing equipment located under
the hood shall shutdown when the extinguishing system activates. 1998 NFPA
17A Section 2-4.3.1.
When its fire-extinguishing system discharges, all electrical outlets shall be turned
off.
Piping shall be rigidly supported to prevent movement.
All discharge nozzles shall be provided with caps, covers, or other suitable
protective devices. 1998 NFPA hA. Section 2-3.1.4.
Installation shall comply with NFPA 96 & 17A.
Hood and duct construction and installation shall be in accordance with the 2001
Uniform Mechanical Code and nationally recognized standard. These assemblies
are subject to approval and inspection by the local Building Official and are not
part of the Fire Authorities review process except as it relates to .the installation of
the hood extinguishing system. 1998 NFPA 17A Section 1-2.
All movable cooking equipment shall be provided with a means to ensure that it is
correctly positioned in relation to the appliance discharge nozzle during cooking
operations. (1998 NFPA hA Section 3-6.3.)
Chemical fire extinguishing systems shall be tested prior to placing in service.
Test shall be witnessed by OCFA Inspector. 1998 NFPA hA Section 1-2.
When its fire-extinguishing system discharges, make-up air supplied internally to
a hood shall be shut off. 1998 NFPA 96 Section 5-3.
A hood exhaust fan(s) shall continue to operate after the extinguishing system has
been activated, unless fan shutdown is required by a listed component of the
ventilation system or by the design of the extinguishing system. 1998 NFPA 96
Section 52.3.
JUN IJUL
2007
INTERSTATE
FIRE PROTECTION
36140 Jana Lane Wildomai CA 9259
800=470=FIRE
2 1 3 1 4 1 5.617 8 1 91011121314
lIe 11711811912.01211221231241 2512612712812934
tte Of
W
091m saw
4795••
INTERSTATE FIRE PRCICTIOhL
4~Q46 AL
13WOO6
000
...
JAN
State
Contractors
License
# 747953
Type C-16