HomeMy WebLinkAbout1525 FARADAY AVE; 290; FPC2018-0095; Permit']I kr'city of Carlsbad Print Date: 04/20/2022 Job Address: 1525 FARADAY AVE. # 290, CARLSBAD, CA 92008-7379 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121302700 Track #: Valuation: $39,673.03 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: NEWPORT NATIONAL SPEC SUITE 290 - SPRINKLER TI (10 HEADS) Permit No: FPC2018-0095 Status: Closed - Finaled Applied: 03/21/2018 Issued: 04/10/2018 Finaled Close Out: 02/25/2021 Inspector: Final Inspection: Applicant: FPContractor: PACIFIC FIRE SYSTEMS INC PACIFIC FIRE SYSTMES INC DARIEN MORAN 12316 OAK KNOLL RD, # STE A 12316 OAK KNOLL RD POWAY, CA 92064-5363-SAN DIEGO P0 WAY, CA 92064-5363-SAN DIEGO (858) 722-9865 (858) 883-2333 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov MATERIAL DATA SUBMITTAL Newport National Corporation Spec Suite - 290 Tenant Improvement 1525 Farafday Avenue, Suite #290 Carlsbad, CA 92008 FPC20I8-0095 1525 FARADAY AVE # 290 NEWPORT NATIONAL SPEC SUITE 290- SPRINKLER TI (10 HEADS) 2121302700 3/21/2018 FPC20I 8-0095 1 FiRE SYSTEMS, INC. Pacific Fire Systems, Inc. 12316 Oak Knoll Road, Suite A Poway, CA 92064 858-883-2333 Phone 9 858-883-2334 Fax tqCJ3 Fire Suppression & Building Products Technical Services 800-381-9312 1 +1-401-781-8220 www.tyco-fire.com Series TY-FRB — 2.8, 4.2, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following, A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. ,: Model/Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2" NPT TY1231: Pendent 2.8K, 1/2" NPT TY2131: Upright 4.2K, 1/2" NPT TY2231: Pendent 4.2K, 1/2" NPT, TY3131:. Upright 56K, 1/2"NP1 TY3231: Pendent 5.6K, 1/2"NPT 'Y4131: Upright 8.OK, 3/4- NPT TY4231: Pendent 8.0K, 3/4" NPT TY4831: Upright* 8.0K, 1/2- NPT TY4931: Pendent* 8.0K, 1/2" NPT *Eastern Hemisphere Sales Only Page 1 of 10 JULY 2010 TFPI7I SSP DEFLECTOR* 2-7/8" (73,0 mm) DIA. 7/16" (11,1 mm) ESCUTCHEON PLATE SEATING SURFACE / 2-3/16' (55,6 mm) 1-1/2" 1,1 mm) 1/2" NPT SSP DEFLECTOR* STYLE 10or20 RECESSED ESCUTCHEON 2-7/8' (73,0 mm) DIA. SSU * NOMINAL MAKE-IN DEFLECTOR 6* 5 7/16" I (11,1 mm) ifViiNI1 I NOMINAL 2 2- MAKE IN 3/16" - ______ W (556 mm) RENC FLATS 1/2" NPT TFPI7I Page 2 of 10 7/16 (11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 5$ I 7/16 I FEW 2-1/4 4 (11,1 mm) NOMINAL (57,2 mm) 2 MAKE-IN 3j 2-3/16 1-9/16 (55,6 mm) WRENCH (39,7 mm) I I \1 FLATS 7 --- t I - 1/2 NPT CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly - Compression * Temperature rating is indicated on deflector or adjacent to 2- Button 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY113I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Assembly Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TV-FRB UPRIGHT 'TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE STYLE 10 or 20 RECESSED ESCUTCHEON -7 2-3/16" (55,6 mm) 7/16(11,1 mm) SSU * NOMINAL MAKE-IN DEFLECTOR NAL !1I!I!iI - WRENCH LATS 1/2" NPT SSP DEFLECTOR* 2-7/8" (73,0 mm) DIA. SSU* DEFLECTOR 4 ir'TTJ _ gYLk TFPI7I Page 3 of 10 CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 1/2 (12,7 mm) ESCUTCHEON STYLE 30 or 40 NOMINAL PLATE SEATING RECESSED MAKE-IN NPT SURFACE ESCUTCHEON 25i'16' (58,7 mm) 1-9/16' I (39,7 mm) W f I SSP DEFLECTOR * ---- 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Assembly Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4 131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT TFPI7I Page 4 of 10 7/16 (11,1 mm) SSU NOMINAL DEFLECTOR MAKE-IN 1/2 NPT t 7/16 I 2-1/4 (11,1 MM) _________ _______ 4 I NOMINAL _________ (57,2 mm) 5 JT55,6 MAKE-IN _H_ 2-3/16 1-9/16 mm) WRENCH (39,7 mm) _______ _______ ______ FLATS SSP*_-... 1/2 NPT DEFLECTOR CROSS SECTION UPRIGHT PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly5 * Temperature rating is indicated on deflector or adjacent to 2 - Button - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/ps1112 (40,3 LPM/barl/2) K=4.2 GPM/psi112 (60,5 LPM/bar112) K=5.6 GPM/psi112 (80,6 LPM/bar112) K=8.0 GPM/psi1l2 (115,2 LPM/bar1/2) Temperature Rating Refer to Table and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Beryllium Nickel w/Teflont Bulb ......................Glass Compression Screw........Bronze Deflector...........Copper/Bronze Bushing (K=2.8) ...........Bronze t Registered Trademark of Dupont Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB Sprinklers must be installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C and 3/32 inch (2,4 mm) for the 2860F11410C temperature ratings. Obtain a leak-tight 1/2 inch NPT sprin- kler joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Install Pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME I PLATED I WHITE*** POLYESTER 2.8 1/2" NPT PENDENT (1Y1231) and UPRIGHT (TY1131) 135°F/57°C Orange 1, 2, 3, 4 155°F/68°C Red 175°F!79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY1231)* Figure 6 135°F/57°C Orange 1,2,4 155°F/68°C Red 175°F/79°C Yellow 200°F193°C Green RECESSED PENDENT (TY1231)** Figure 7 135°F/57C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57°C Orange 1,2 155°F/68°C Red 175°F/79°C Yellow 200F/93C Green 286F/141°C Blue RECESSED (TY2231)* Figure 8 135°F/57°C Orange PENDENT 155°F!68°C Red 175°F/79°C Yellow 200°F193°C Green RECESSED PENDENT (TY2231)** Figure 9 135°F/57°C Orange 155°F/68C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: Listed by underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I WHITE*** POLYESTER LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 3, 5 155F/68°C Red 175F/79°C Yellow 200°F/93°C Green 286°F/141°C RECESSED PENDENT (1Y3231)* Figure 10 135°F/57C Orange 1, 2, 4, 5 Blue N/A 155°F/68°C Red 175°F/791C Yellow 200°F/93°C Green 286°F/141°C RECESSED PENDENT (TY3231)** Figure 11 135°F/57°C Orange 1, 2, 3, 4, 5 Blue N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57C Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C RECESSED PENDENT (TY4231)* Figure 12 135°F/57°C Orange 1, 2, 5 Blue N/A 155F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C RECESSED PENDENT (TY4231)** Figure 13 135°F/571C Orange 1, 2, 3, 5 Blue N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C 80 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1, 2, 4, 5, 6 Blue 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93C Green 286°F/141°C NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL i CHROME WHITE LEAD FACTOR BRASS I PLATED I POLYESTER COATED PENDENT (TY1231) and 2.8 UPRIGHT (TY1131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) N/A PENDENT (TY3231) PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and UPRIGHT (TY4831) 175 PSI (12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) Only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig- ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. After ceiling installation and finish- ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TABLE C MAXIMUM WORKING PRESSURE Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. (.JtLW Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: were modified or over-heated. were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. are leaking or exhibiting visible signs of corrosion. were exposed to corrosive products of combustion but have not oper- ated, if you cannot easily remove combustion by-products with a cloth. have a cracked bulb or have lost liq- uid from the bulb. Refer to the Instal- lation section in this data sheet. 2-7/8' DIA. (73,0 mm) 3/4' (19,1 mm) 2-1/4' DIA. 1/4' (6,4 mm) I I (57,2 mm) MOUNTING DIAT I 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING TFPI7I Page 8 of 10 MOUNTING SURFACE 1-5/16' (33,3 mm) 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4' (19,1 mm) 2-1/4' DIA. (57,2 mm) 1/4(6,4mm) I D1 MOUNTING A-rr 1/8' (3,2 mm) MOUNTING SURFACE CLOSURE SER 1-1/4" (31,13 mm) 3/4' (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. (73,0 mm) 1/2±1/8' 1/2' (12,7 mm) (12,7±3,2 mm) 2-1/4' DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8' (3,2 mm) I MOUNTING SURFACE II 6' (33,3 mm) CLOSURE SERIES TY-FRB 1-1/16 (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. (73,0 mm) 1/2±1/8" 1/2' (12,7 mm) E (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF (57,2 mm) I MOUNTING SPRINKLER PLATE I FITTING I I (3,2 mm) I I MOUNTING SURFACE SERIES 1-1/4' (31,8 mm) CLOSURE 1Y-FRB 1(25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT CLOSURE SERIES TY-FRB 5/8±1/4' (15,9±6,4 mm) FACE OF SPRINKLER FITTING Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Responsibility lies with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. TFPI7I Page 9 of 10 2-7/8 DIA. - - 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) - (15,9±6,4 mm) - 2-1/4' DIA. 1/4(6,4mm) FACE OF (57,2 MM) MOUNTING SPRINKLER PLATE FITTING 1/8" ,2 MOUNTING SURFACE SERIES 1-1/4(31,8mm) CLOSURE IY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. (73,0 mm) I 3/4' (19,1 mm) 2-1/4" DIA. 1/4(6,4mm) (57,2 mm) MOUNTING - OIAT 1/8" (3,2 mm) MOUNTING $ SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)J TY-FRB 13/16(20,6mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8" DIA. - (73,0 mm) I 1/2" (12,7 mm) 2-1/4' DIA. " 1/4 (6,4 mm) I (57,2 mm) I MOUNTING I - OIAT I f I ULflIL_. ; 1/8" (3,2 mm) 1-1/4" (31,8 mm) CLOSURE SERIES 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4' DIA. 1/4" (6,4 mm) (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE FITTING 1/8" / (3,2 mm) T \ MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4 (15,9±6,4 mm) FACE OF SPRINKLER FITTING 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING $ \ - MOUNTING SURFACE Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END "A" USED FOR 1/2' NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4' NPT MODELS) FIGURE 14 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 10 of 10 I P/N 57- XXX- X- XXX I L MODEL/SIN 330 2.81K UPRIGHT (1/2"NPT) 1Y1131 331 2.81K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.61K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.01K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2"NPT) 1Y4931* SPRINKLER TEMPERATURE L FINISH RATINGS 1 NATURAL BRASS 135 135°F (57°C) 4 WHITE POLYESTER 155 155°F (68°C) 3 WHITE (RAL9010)° 175 175°F (79°C) 9 1 CHROME PLATED 200 200°F (93°C) 7 I LEAD COATED I I 286 1 286°F (141°C) * Eastern Hemisphere sales only. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. express or implied, including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. * Refer to Technical Data Sheet TFP770. Copyright 0 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved. FM Approved and Fully Listed Sprinkler Pipe Wheatland's WLS steel fire sprinkler pipe is hot-dip galvanized to meet FM requirements for dry systems and is UL, C-UL and FM Listed Approvals and Specifications The product meets or exceeds the following standards: ASTM: A795, Type F, Grade A ANSl/ASME B1.20.1 pipe threads NFPA13 Manufacturing Protocols WLS is subjected to the toughest possible testing protocols to assure the highest quality and long-lasting performance. Finishes and Coatings WLS is finished in black or hot-dip galvanized. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SPECIFICATIONS NIPS NOM OD NOM ID UL CRR WLS WLS Schedule Schedule WLS Schedule Nominal Pcs./ PCS./ 10 40 40 wt./ft. Lift 21' Lift 25 1 1.315 1.087 N/A 1,049 .57 1.00 1.462 70 60 11/4 ' 1.660 1.426 1.442 1.380 .46 1.00 1.928 55 45 11/2 1.900 1.650 1.682 1.610 .64 1.00 2.370 45 40 2 2.375 2.125 2.157 2.067 .52 1.00 3.004 35 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. & C@ A. I.>. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: 0 BLACK 0 HOT-DIP GALVANIZED 00 - t Tube IMO STEEL GROUP Fig. 69 - Beam Clamp Retaining Strap Size Range - 3/8 thru 7/8 rod by 4" thru 16" length.* Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (2010) 9.3.7.1. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mech- anism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, type, length "B" and rod size being used with beam clamp Note - Minimum return on Strap: 1". Dimensions Type Rod Size A Hole Size B 1 3/8 7/16 1/2 9/16 Specify Specify 2 5/8 11/16 3/4 13/16 Specify Specify 3 3/8 -7/8 Specify Specify * Longer lengths are available, consult factory. Component of State of California OSHPD Approved Seismic Restraints System OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737,0330 CUSTOMER SERVICE • 800.786.5266 '4 www.tolco.com Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1A6 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13A6 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig 65 and Fig. 66 Reversible C-Type Beam Clamps 314" and 11/4" Throat Openings Component of State of California OSHPO Approved c YL us usno Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4' (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2' rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Develooment (OSHPD). For additional load, spacing and placement relating to OSHPD oroiects, olease refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH; 951.737.5599 • FAX: 951.737.0330 .1 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 2 - Adjustable Band Hanger Size Range - Size 21/2 thru 6" pipe. Material - Carbon Steel, Pre-Galvanized Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals - Factory Mutual Engineering approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish - Pre-Galvanized Note - Available in Stainless Steel materials. Order By - Figure number, pipe size and material C®US LISTED Dimensions • Weights Pipe Max. Rec. Approx. Size Rod Size A B C Load Lbs. Wt./100 21/2 1/2* 53/4 41/4 1/8 600 41 3 1/2k 6 41/s 11/4 600 45 31/2 1/2* 7/8 51/4 21/8 600 52 4 5/8* 7 /8 5 15/8 1000 59 5 5/8** 9 61/8 21/4 1250 97 6 3/4** 9I8 61/2 1/8 1250 139 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com ?owers FASTENERS PRODUCT INFORMATION VertigoTM Vertigo TM Rod Hangers SECTION CONTENTS Page No. General Information....................1 IPRODUCTIDESCRIPTION Vertigo is an all steel threaded fastening system for suspending steel threaded rod vertically Installation Specifications............2 overhead in pipe hanging, fire protection, electrical conduit and cable-tray applications. Material Specifications ...............2 Vertigo are available in three versions which can be installed in a variety of base materials Performance Data ........................3 including steel purlins bar joists and beams wood frame columns and beams as well as Ordering Information..................7 concrete ceilings, beams and columns. Steel threaded rods in 1/4", 3/8" and 1/2" diameters can be vertically suspended with Vertigo. In wood and steel base materials, Vertigo is also offered in a side mount style for lateral installation of 1/4" and 3/8" diameter steel threaded rods onto joists, columns and overhead members. For all steel and wood Vertigo fasteners, a universal Vertigo Socket Driver is recommended to provide proper installation with a screw gun or hammer drill. Concrete Steel Vertigo Vertigo fasteners should be installed with the appropriate size standard drive sockets and adjustable torque, battery powered screw gun or hammer drill. t' GENERAL APP 1_1 I 'liii . Hanging Pipe and Sprinkler Systems • Suspending Conduit and Cable Trays Lighting Systems and Overhead Utilities • HVAC Ductwork and Strut Channels Wood Vertigo Suspended Ceilings • Mounting Security Equipment FEATURES AND BENEFITS + One system for all rod hanging applications in steel, wood and concrete + Ease and speed of overhead installation oncrete:verti9à + Lower in-place cost, when compared to beam clamps, lag bolts and dropins (WedgeBOltOT) + Steel and wood Vertigo can be installed with a screw gun or hammer drill + Concrete Vertigo can be installed with an adjustable torque, battery powered screw gun or hammer drill ANCHOR MATERIALS + Side mount versions available for steel and wood Vertigo + The universal socket can be used for the steel and wood Vertigo Zinc Plated Carbon Steel ANCHOR SIZE RANGE (TYP.) APPROVALS AND LISTINGS 1/4"tol/2" for Steel FM Approvals (FM) - (see listing for applicable sizes and types). 1/4" to 1/2" for Wood Pipe Hangers components for automatic sprinkler systems - File No. JI 3015153 1/4" to 1/2" for Concrete Underwriters Laboratory (UL) - (see listing for applicable sizes and types). SUITABLE BASE MATERIALS Pipe Hangers - File No. EX 1289 Luminaire - File No. E362339 Steel Purlins and Beams Wood and Timber GUIDE[11 i I [.] Normal-Weight concrete Structural Lightweight concrete CSI Divisions: 03 16 00 - Concrete Anchors, 05 05 19 - Post-Installed Concrete Anchors, Hollow Core Concrete Plank 05 05 23 - Metal Fastenings and 06 05 23 - Wood, Plastic, and Composite Fastenings. Rod Hangers shall be Vertigo anchors as supplied by Powers Fasteners, Inc., Brewster, NY. Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com ?owers VertigoTM PRODUCT INFORMATION FASTENERS INSTALLATION SPECIFICATIONS Steel Vertigo Point Style #3 #5 Self Drilling Range 0.036" (20 gauge) - 0.188" (3/16") 0.188" (3/16') - 0.500" (1/2") Screw Size (UNC) 1/4-20 thread 1/4-20 thread Root Diameter (in.) 13/64 13/64 Thread Length (in.) 1-3/16" (1-1/2"screw) 31/32"(1-1/2"screw) Flange Thickness (in.) 1/16 1/16 Drill Speed (RPM) 500-1,500 500-1,500 Install with universal steel and wood socket. Wood Vertigo Screw Size 1/4" Thread Forming 5/16" Thread Forming Pre-drill Diameter (in.) (if required) 1/8 1/8 Point Style Type 17 Type 17 Root Diameter (in.) 3/16 7/32 Thread Length (in.) Screw length less 5/16 Screw length less 5/16 Flange Thickness (in.) 1/16 1/16 Install with universal steel and wood socket. Vertigo Couplings (Steel & Wood) Screw Size 1/4" 3/8" 1/2" 114" 3/8" Coupling Size and Type Vertical Vertical Vertical Side Side Thread Size (UNC) 1/4-20 3/8-16 1/2-13 1/4-20 3/8-16 Thread Depth (in.) 3/8 3/8 3/8 (through) (through) Width (flat to flat) (in.) 5/8 1 5/8 1 5/8 5/8 5/8 Height (in.) 13/16 13/16 13/16 13/16 13/16 Cóiicrete Vertigo (Wede-BoltOT) Rod Diameter/Anchor Size 1/4" (_3i8/ 1/2" ANSI Drill Bit (in.) 1/4 1/4 3/8 Overall Screw Shank Length 1-1/4 1-1/2 2-3/4 Anchor Thread Length (in.) 1-1/8 1-3/8 2-1/2 Root Diameter (in.) 15/64 15/64 23/64 Coupling /Washer Height (in.) 27/64 9/16 53/64 Integral Washer O.D. (in.) 31/64 39/64 31/32 Coupling Thread Size (UNC) 1/4-20 3/8-16 1/2-13 Coupling Thread Depth (in.) 3/8 1/2 3/4 Socket Driver Size (in.) 3/8 1/2 11/16 Install with universal steel and wood socket. Installation Guidelines When installing Vertigo - , fasteners, eye protection should be worn as a . .; safety precaution. If pm-drilling is required (certain types of wood truss/wood joist and all concrete base materials), select the recommended drill bit type and diameter. For Concrete Vertigo only, drill to the appropriate embedment depth, adding at least one diameter (1/4" to 1/2") to the drilling depth to prevent the tip of the fastener from running into a dead end at the rear of the anchor hole. Concrete Select the appropriate socket driver for the anchor size and type to be installed and mount into chuck of installation tool. Insert the Vertigo fastener into the socket driver, and install perpendicular to the base material surface. Drive the fastener with a smooth steady motion until the coupling is firmly seated against the surface of the base material. Thread the appropriate Steel diameter steel threaded rod or threaded bolt into the coupling. The threaded rod or bolt should fully engage the thread length of the coupling on a vertical mount fastener. The threaded rod or threaded portion of the bolt can pass through coupling of a side Wood mount fastener. For UL and FM listings for Pipe Hangers, Steel Vertigo should be installed with a retaining nut. Steel and Wood Vertigo Component Component Material Screw Body AISI 1018-1022 (Case Hardened) Coupling AISI 1018-1022 (Case Hardened) Zinc Plating ASTM 8633, SC1,Type III (Fe/Zn5) Concrete Vertigo (Wedge-Bolt 01) Component Component Material Anchor Body Case Hardened 10B21 Carbon Steel Zinc Plating ASTM B633, SC1,Type Ill (Fe/Zn 5) www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Steel Vertigo - Ultimate Tension Load Capacities when Installed in Minimum ASTM A 36 Steel (Beams) and ASTM A 572 Steel (Purlins)1'2 Anchor Size! Minimum Steel Gauge (Thickness) _____________ _____________ 20 0.036" 18 0.048" 16 0.060" 14 0.075" 12 0.105" 3/16" 0.187" 1/4" 0.250" Rod Diameter in. Mount Direction Screw Shank Size and Length (mm) lbs. lbs. lbs. lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) (kN) (kN) (kN) Vertical 1/4-20 x 1" (w/nut) 1.550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 1/4 Vertical 1/4-20 x 1 " 405 620 985 1,160 1,560 3,205 5,040 (6.4) (1.8) (2.8) (4.4) (5.2) (7.0) (14.4) (22.7) Side 1/4-20 X 1" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 - (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) Vertical 1/4-20 x 1" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Side 1/4-20x1-1/2"(wMull 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 3/8 Vertical 1/4-20x 1-1/2" 405 620 985 1,160 1,560 3,205 (9.5) (1.8) (2.8) (4.4) (5.2) (7.0) (14.4) - Side 1/4-20 x 1-1/2" 405 620 985 1,160 1,560 1,965 (1.8) (2.8) (4.4) (5.2) (7.0) (8.8) - Vertical 1/4-20 x 2" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Vertical 12-20x 1-1/2 " 495 710 920 1,560 2,050 3,280 5,040 1/2 (2.20 (3.2) (4.1) (7.0) (9.2) (14.8) (22.7) (12.7) Vertical 12-20x1-1/2"(wkiut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 1. For Steel Vertigo loaded perpendicular to threaded rod (shear) the ultimate load capacity for the anchor is 1,965 lbs in nominal 20 gage steel (0.036") Wood Vertigo - Ultimate Tension Load Capacities when Installed in Wood Base Materials (Structural Wood and Timber)',' Anchor Size / Embedment Depth Wood Member (Type) ______________________ Fir Pine Spruce Rod Diameter Mount Screw Shank Size in. Direction and Length in. (mm) lbs. lbs. lbs. (mm) (kN) (kN) (kN) 1/4 Vertical 1/4x 1 1 (25.4) 685 (3.1) 650" 650 (2.9) (2.9) (6.4) Side 1/4 x 2" 2 1,510 1,510 1,510 (50.8) (6.8) (6.8) (6.8) Vertical 1/4x1 1 (25.4) 685 (3.1) 650" 650 (2.9) (2.9) Side 1/4x1" 1 (25.4) 685 (3.1) 550 (2.9) 650 (2.9) Vertical 1/4x2" 2 1,510 1,510 1,510 (50.8) (6.8) (6.8) (6.8) Side 1/4x2" 2 1,800 1,800 1,800 3/8 (50.8) (8.1) (8.1) (8.1) (9.5) Vertical 114x3" 3 2,075 1,510 1,510 (76.2) (9.3) (6.8) (6.8) Vertical 1/4x4" 4 2,075 1,510 1,510 (101.6) (9.3) (6.8) (6.8) Vertical 5/16" x2-1/2" 2-1/2 2,670 3,110 3,110 (63.5) (12.0) (14.0) (14.0) Side 3/8" x 2-1/2" 2-1/2 1,450 1,530 1,380 (63.5) (6.5) (6.9) (6.2) 1/2 Vertical 5/16" x 2-1/2" 2-1/2 2,670 3,110 3,110 (12.7) (63.5) (12.0) (14.0) (14.0) 1, Truss/joist manufacturers may require pre-drilled holes with wood depending on the location of the anchor installation. Consult with the truss/joist manufacturer for details. 2. Wood Vertigo are recommended to be installed with the Universal Steel & Wood Nut Driver. Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 3 ?owers VertigoTM PRODUCT INFORMATION FASTENERS Concrete Vertigo - Ultimate Load Capacities when Installed in Normal-Weight Concrete,.' Anchor Size ! ANSI Drill Bit Minimum Concrete Compressive Strength (f c) Embed. Depth 2,000 psi (13.8 MPa) 4,000 psi (20.7 MPa) 6,000 psi (41.4 MPa) Rod Diameter Mount Screw Shank Size Diameter h, Tension Shear Tension Shear Tension Shear Direction and Length dbit in. (mm) in. (mm) lbs. lbs. lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) (kN) (kN) 1/4 Vertical 1/4"x1 -1/4" 114!' 1-1/4 1,390 1,810 1,950 2,440 2,070 2,570 (6.4) (31.8) (6.3) (8.1) (8.8) (11.0) (9.3) (11.6) 3/8 Vertical 1/4" xl-l/2 " 1/4" 1-1/2 1,760 2,580 2,595 2,640 2,770 2,700 (9.5) (38.1) (7.9) (11.6) (11.7) (11.9) (12.5) (12.2) 1/2 Vertical 3/8"x2-3/4" 3/8" 2-3/4 5,320 5,250 6,050 6,330 8,620 7,410 (12.7) (69.9) (23.9) (23.6) (27.2) (28.5) (38.8) 1 (33.0) The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load, Linear interpolation may be used to determine ultimate loads for intermediate compressive strengths. tZ Concrete Vertigo - Ultimate Load Capacities when Installed Through Metal Deck into Structural Lightweight Concrete' 13A Lightweight Concrete Over Minimum 20 Ga. Metal Deck Anchor Size! Rod Diameter Embedment Depth f'c ~! 3,000 psi (20.7 MPa) Minimum 4 1/2" Wide Deck d in. Tension Load at 45 in. (mm) (mm) lbs. lbs. (kN) (kN) 1/4 1-1/4 800 1,140 (6.4) (31.8) (3.6) (5.1) 3/8 1-1/2 1,780 1,500 (9.5) (38.1) (8.0) (6.8) 1/2 2-3/4 3,880 2,920 (12.7) (69.9) (17.5) (13.1) The values listed above are ultimate and allowable load capacities for Vertigo rod bangers installed in sand-lightweight concrete. The metal deck shall be minimum No. 20 gauge thick steel (0.035-inch base metal thickness (0.89 mm)) conforming to ASTM A 653/ A 653M. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. The tabulated load values are for anchors installed with a minimum flute edge distance of 1-1/2-inch. Concrete Vertigo - Ultimate Tension Load Capacities when Installed in Hollow Core Concrete Plank',' Anchor Size / Rod Diameter ANSI Drill Bit Diameter Embedment Depth Center of Web Center of Core Mount Screw Shank Size lbs. lbs. in. Direction and Length db in. (kN) (kN) (mm) in, (mm) 1/4 (6.4) Vertical 1/4"x 1-11T 1/4" 1-1/4 2,775 (12.3) 1,920 (31.8) (8.5) 3/8 (9.5) Vertical 1/4"x1-1/2" 1/4" 1-1/2 (38.1) 3,700 (16.5) 2,570 (11.4) 1/2 (12.7) Vertical 3/8"x2-3/4" 3/8" 2-3/4 8,240 (36.7) 3,480 (69.9) (15.5) Tabulated load values are for anchors installed in 8-inch-thick hollow core plank with minimum compressive strength of 5,000 psi at the time of installation. The 4' 06' normal-weight concrete members features include 1-1/2" cover above and below cores and a minimum web thickness of 1-1/2". The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. www.powers.com Canada: (905) 673-7295 or (51 4) 631-4216 Powers USA: (800) 524-3244 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Steel Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) and Underwriter's Laboratories (UL) listings for Pipe Hangers' Anchor Size! Maximum UL Minimum FM Minimum Rod Diameter Mount Screw Shank Pipe Size Steel UL Test Load Steel FM Test Load Cat. No. in. Direction Size and Point Style . Thickness lbs. Thickness lbs. (mm) Length Ifl. (mm) in. (kN) in. (kN) (mm) (mm) 4 0.060 1,500 0.096 1,475 7158 Vertical 1/4-20x 1 " #3 (101.6) (1.5) (6.8) (2.4) (6.6) 4 0.060 1,500 0.096 1,475 7184 Side 1/4-20x1" (101.6) (1.5) (6.8) (2.4) (6.6) 7160 Vertical 1/4-20 x 43 4 0.060 1,500 0.096 1,475 3/8 1-112" (101.6) (1.5) (6.8) (2.4) (6.6) 7186 Side 1/4-20 x #3 4 0.060 1,500 0.096 1,475 (9.5) 1-1/2" (101.6) (1.5) (6.8) (2.4) (6.6) 4 0.060 1,500 0.096 1,475 7154 Vertical 12-20 x 1-1/2" #5 (101.6) (1.5) (6.8) (2.4) (6.6) 4 0.060 1,500 0.096 1,475 7188 Side 1/4-20x2" #3 (101.6) (1.5) (6.8) (2.4) (6.6) 4 0.060 1,475" 1,500 0.096 7201 Side 12-20 x 1-1/2 #5 (101.6) (1.5) (6.8) (2.4) (6.6) 7161 1/2 Vertical 12-20x 1-1/2" #5 8 0.250 4,050 0.250 3,800 (12.7) (203.2) (6.4) (18.2) (6.4) (17.1) 1. Steel Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. For UL and FM listings, Steel Vertigo must be installed with a retaining nut. Wood Vertigo - Ultimate load Capacities for Factory Mutual (FM Global) and Underwriter's Laboratories (UL) listings for Pipe Hangers' Anchor Size I Rod Diameter Screw Shank Embedment Depth UL Maximum Size UL Test Load FM Maximum Size FM Test Load Cat. No. in. Mount Direction Size and . Pipe lbs. Pipe lbs. (mm) Length in. (mm) in. (mm) (kN) in. (mm) (kN) 2 3 7165 Vertical 1/4 x 2" 1,050 (50.8) - - (76.2) (4.7) 2 3 7170 Side 1/4 x 2" 1,050 (50.8) - - (76.2) (4.7) 7167 Vertical 1/4x3" 3 3 1,050 - - 3/8 (9.5) (76.2) (76.2) (4.7) 4 3 1,050 7169 Vertical 1/4 x " - - (101.6) (76.2) (4.7) 2-1/2 4 1,500 4 1,475 7162 Vertical 5/16" x2-1/2" (63.5) (101.6) (6.8) (101.6) (6.6) 7156 Side 5/16" x 2-1/2" 2-1/2 4 1,500 (63.5) - - (101.6) (6.8) 1. Wood Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. No pre-drilling was done in the wood base materials. Concrete Vertigo - Ultimate load Capacities for Factory Mutual (FM Global) Listings for Pipe Hangers' Anchor Size / Rod Diameter Mount Screw Shank Size ANSI Drill Bit Diameter Embedment Depth FM Maximum Pipe Size FM Test Load - Cat No. in. Direction and Length in. (mm) . in. lbs. (kN) (mm) i n. (mm) 7173 3/8 (9.5) Vertical 1/4" x 1-1/2" 1/4" ___ 1-1/2 (38.1) 4 (101.6) 1,475 (6.6) 7175 1/2 (12.7) Vertical 3/8" x 2-3/4" 3/8" 2-3/4 (69.9) 4 (203.2) 3,800 (17.1) 1. Tabulated load values are for anchors installed in 8 inch thick hollow core plank with minimum compressive strength of 4,000 psi at the time of installation. The 4' x 6' normal-weight concrete Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 5 ?owers VertigoTM PRODUCT INFORMATION FASTENERS Steel Vertigo - Ultimate Load Capacities for Underwriter's Laboratories (UL) Listings - Luminaire' Catalog Number Anchor Size/Rod Dia. In. Mount Direction Screw Shank Size and Length (mm) Point Style Mounting Surface UL Test Load (lb.) 7155 1/4 Vertical 1/4-20 a 1 #3 16 Gauge Steel 45 7157 3/8 Vertical 1/4-20 x 2 #3 16 Gauge Steel 45 7158 3/8 Vertical 1/4-20 a 1 #3 16 Gauge Steel 45 7159 3/8 Vertical 1/4-20 x 1-1/2 #3 16 Gauge Steel 45 7160 1/4 Vertical 1/4-20 x 1-1/2 #3 16 Gauge Steel 45 7183 1/4 Side 1/4-20 a 1 #3 16 Gauge Steel 75 7184 3/8 Side 1/4-20 a 1 #3 16 Gauge Steel 75 7186 3/8 Side 1/4-20 a 1-1/2 #3 16 Gauge Steel 75 7188 3/8 Side 1/4-20 a 2 #3 16 Gauge Steel 75 7155 1/4 Vertical 1/4-20 a 1 #3 22 Gauge Steel 25 7157 1/4 Vertical 1/4-20 a 2 #3 22 Gauge Steel 25 7158 3/8 Vertical 1/4-20 a 1 #3 22 Gauge Steel 25 7159 3/8 Vertical 1/4-20 x 1-1/2 #3 22 Gauge Steel 25 7160 3/8 Vertical 1/4-20 a 1-1/2 #3 22 Gauge Steel 25 7183 1/4 Side 1/4-20 x 1 #3 22 Gauge Steel 45 7184 3/8 Side 1/4-20 x 1 #3 22 Gauge Steel 45 7186 3/8 Side 1/4-20 x 1-1/2 #3 22 Gauge Steel 45 7188 3/8 Side 1/4-20 a 2 #3 1 22 Gauge Steel 1 45 1. Steel Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. For UL Luminaire listing, Steel Vertigo does not require a retaining nut. www.powers.com Canada: (905) 673-7295 or (51 4) 631-4216 Powers USA: (800) 524-3244 Cat. No. Rod Dia. Screw Shank Size and Length I Thread Style I Pre-Drill Diameter (If Required) std. Box Std. Ctn. 7171 1/4" 1/4" x.1-114'" .1-j/4" ')Wedge -Bolt OT 1/4" ANSI 100 500 r7173 - _3/8" 1/4' x.i-1/2"- Wedge-Bolt OT 1/4" ANSI 100 500 7175 1/2" 1/4" x 2-3/4" Wedge-Bolt OT 3/8" ANSI 50 250 Drive Sockets and Pole Tool Cat. No. Description RPM Box Ctn. 7166 6'-12' Pole Tool (includes three Jaw Chuck) N/A 1 1 7187 Universal Steel & Wood Socket (Red) 500 to 1500 RPM 5 25 7195 1/4" Concrete Socket (Blue) - 5 25 7197 3/8" Concrete Socket (Blue) - 5 25 7198 1/2" Concrete Socket (Blue) - 5 25 44 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Steel Vertical Hanger (#3 for Purlins, #5 for Beams) Cat. No. Rod Dia. Screw Shank Size and Length Point Style Self Drilling Range Std. Box Std. Ctn. 7155 1/4" 1/4"-20x 1" #3 0.036" (20 gauge) to 0.1881, (3/16") 100 500 7157 3/8" 1/4"-20x2" #3 100 500 7158 3/8" 1/4-20 xl" (w/nut) #3 100 500 7159 3/8" 1/4"-20x1-1/2"(wlnut) #3 100 500 7160 3/8" 1 1/4 -20 x 1-1/2" (w/nut) #3 100 500 7152 1/4" 1 12"-20x1-112" #5 0.188"(3116")to 0.500" (1/2") 100 500 7154 3/8" 12"-20x1-112"(w/nut) #5 100 500 7161 1/2" 12"-20x1-1/2" (w/nut) #5 100 500 Steel Side Hanger (#3 for Purlins, #5 for Beams) Cat. No. Rod Dia. Screw Shank Size and Length Point Ste Self Drilling Range Std. Std. Box Ctn. 7183 1/4" 114"-20x1" #3 0.036" (20 gauge) to 0.188 (3/16") 100 500 7184 3/8" 114"-20x 1" (w/nut) #3 100 500 7186 3/8" 1/4"-20x 1-1/2" (w/nut) #3 100 500 7188 3/8" 1/4"-20x2" (w/nut) #3 100 500 7200 1/4" 12"-20x1-112" #5 0.188"(3116")to 0.500"(112") 50 300 7201 1 3/8" 1 12"-20x1-1/2"(w/nut) #5 100 1 600 Wood Vertical Hanger Cat. No. Rod Dia. Screw Shank Size and Length Point Style Pie-Drill Diameter (If Required) Std. Box Std. Ctn. 7163 1/4" 1/4"x2" Type 17 1/8" 100 500 7203 3/8" 1/4" xl" Type 17 100 500 7165 3/8" 1/4" x2" Type 17 100 500 7167 3/8" 1/4" x3" _jypl7 100 500 7169 3/8" 1/4" x4" Type 17 100 500 7162 3/8" 1 5/16" x 2-1/2" Type 17 100 500 7164 1/2" 1 5/16" x 2-1/2" Type 17 100 500 Wood Side Hanger Cat. No. Rod Dia. Screw Shank Size and Length Point Style Pie-Drill Diameter (If Reguirwi) Std. Box Std. Ctn. 7185 1/4" 1/4" xl" Type 17 1/8" 100 500 7205 3/8" 1/4" xl' Type 17 100 500 7170 3/8" 1/4" x 2" Type 17 100 500 7156 3/8" 5/16" x 2-1/2" Type 17 100 500 Concrete Vertical Hanger Concrete Vertigo Installation Accessories Cat. No. Description Maximum Bit Length Std. Box Std, Ctn. Vertigo Installation Kit: 5864 1/4" and 3/8 Concrete Drive Sockets (Blue) 6" 1 3/4 Universal Steel & Wood Socket (Red) (Sleeve Assembly (same as Cat# 5874) 5874 Sleeve Assembly (5-3/4") 6" 1 - Cat. No. Description Usable Length Std. Tube wt./10 5866 1/4" x 6" Hex Shank SDS Drill Bit 4" 1 1/2 © 2014 Powers Fasteners, Inc. All Rights Reserved. Vertigo is a registered trademark of Powers Fasteners, Inc. For the most current product information please visit www.powers.com Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 7