HomeMy WebLinkAbout1620 FARADAY AVE; ; FPC2019-0108; PermitPER]ET REPORT ("City of Carlsbad Print Date: 04/28/2022 Permit No: FPC2019-0108 Job Address: 1620 FARADAY AVE, CARLSBAD, CA 92008-7313 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121302300 Track #: Applied: 05/08/2019 Valuation: $1,314,093.54 Lot #: Issued: 05/31/2019 Occupancy Group: Project 4: Finaled Close Out: 11/08/2019 #of Dwelling Units: Plan 4: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4: Inspector: Plan Check 4: Final Inspection: Project Title: Description: RQC CORP HEADQUARTERS -SPRINKLER TI (171 HEADS) FPContractor: MILLENNIUM FIRE PROTECTION CORP - INACTIVE 2950 SAN LUIS REY RD OCEANSIDE, CA 92058-1241 (760) 722-2722 FEE AMOUNT FIRE Hourly Services Each Additional Hour $136.00 FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 or 13R System> 100 heads $654.00 Total Fees: $949.00 Total Payments To Date: $949.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 5/7/2019 z I ttit1*i1 - % OI t3 '$&I4U 't(Q F C Is MILLENNIuM FIRE PROTECTION CORP. R Q C CORPORA TE HEAD QA UR TERS 1620 FARADAY AVE. CARLSBAD, CA 92008 Overhead Fire Sprinkler Material Submittal TENANT IMPROVEMENT Table of Contents m OVERHEAD PIPE & FITTING ] RQC CORPORATE HEADQAU RTERS SUNBELT GROUP L.P. ASTM A53 TYPE E GR. A & B PIPE SCOPE Covers black and hot-dipped galvanized ERW Grade A & B pipe. Pipe is intended for mechanical and pressure applications and is acceptable for ordinary uses in steam, water, gas and air lines. Pipe is suitable for welding, threading, grooving and bending. Pipe is not intended for flanging. Produced to ASTM A531A latest revision. Pipe is UL listed & FM approved. HOT-DIPPED GALVANIZED The average weight of zinc coating shall be not less than 1.8 oz./ per sq. ft. of surface (inside and out). When galvanized pipe is bent or otherwise fabricated to a degree which causes zinc coating to stretch or compress beyond the limit of elasticity, some flaking of the coating may occur. HYDROSTATIC TESTING Table 2.2 of ASTM A531A53M Specification. Test pressures will be maintained for a minimum of five seconds. END FINISH Plain End: NPS 1-1/2" and smaller: unless otherwise specified on order, end finish shall be at the option of the manufacturer. NPS 2" and larger: STD and Sch. 80 weights: ends beveled to angle of 300, +50, -00 with a root face of 1/16" + 1/32". Threading: To ANSI Standard B 1.20.1 Couplings: To ASTM Standard A 865. CHEMICAL REQUIREMENTS Composition, max. % Carbon .25, Manganese .95, Phosphorus .05, Sulfur .045, *Copper .40, *Nickel .40, *Chromium .40, *Molybdenum .15, *Vanadium .08 The combination of *elements shall not exceed 1% SUBMITTAL DATA TENSILE REQUIREMENTS Tensile Strength, min. Gr. A 48000 psi Gr. B 60000 psi Yield Strength, mm. Gr. A 30000 psi Gr. B 35000 psi Elongation in 2"— Refer to A53 Table x 4. 1, latest revision - ASTM A53/A 53M BENDING TEST (COLD) FOR NPS 2" AND UNDER: Degree of Bend Diameter of Mandrel Standard 900 12 x outside pipe diameter Closed Coiling 90° 8 x outside pipe diameter FLATTENING TEST - NPS 2-1/2" AND GREATER: As a test for quality of the weld, position the weld at 90° from the direcfion of force and flatten until the OD is % of the original outside diameter. No cracks shall occur along the inside or outside surface of the weld. DIMENSIONS AND WEIGHTS BLACK PLAIN END Sch.40 Nominal OD Wall Weight Size Inches Inches LB/FT .840 .109 .85 .1.050 .113 1.13 1.315 .133 1.68 1-1/4" 1.660 .140 2.27 1-1/2" 1.900 .145 2.72 2.375 .154 3.66 2-1/2" 2.875 .203 5.8 3.500 .216 7.58 3-1/2" 4.000 .226 9.12 4.500 .237 10.8 5.563 .258 14.63 6.625 .280 18.99 8" 8.625 .322 28.58 PERMISSIBLE VARIATIONS Minimum wall thickness at any point shall not be more than 12.5% under nominal wall thickness specified. Outside Diameter, NPS 1-1/2" and under, +.016". NPS 2" and over +1%. PRODUCT MARKING Each length of pipe %" NPS and larger is continuously stenciled to show manufacturer, country of origin, grade, type, size, and length, along with UL & FM markings SUNBELT GROUP L.P. ASTM A795 TYPE E GRADE A PIPE SCOPE Covers black and hot-dipped galvanized ERW Grade A steel pipe. Pipe is intended for use in fire protection systems. Pipe is suitable for joining by welding and by roll grooving. Produced to ASTM A7951A latest revision. Pipe is UL listed & FM approved. HOT-DIPPED GALVANIZED The average weight of zinc coating shall be not less than 1.8 oz./ per sq. ft. of surface (inside and out). When galvanized pipe is bent or otherwise fabricated to a degree which causes zinc coating to stretch or compress beyond the limit of elasticity, some flaking of the coating may occur. HYDROSTATIC TESTING Table 1 of ASTM A795/A795M Specification. Test pressures will be maintained for a minimum of five seconds. END FINISH Plain End: NPS 1-1/2" and smaller: unless otherwise specified on order, end finish shall be at the option of the manufacturer. NPS 2" and larger: ends beveled to angle of 300, 50 -00 with a root face of 1/16" +1- 1/32". CHEMICAL REQUIREMENTS Composition, max. % Carbon .25, Manganese .95, Phosphorus .035, Sulfur .035 SUBMITTAL DATA TENSILE REQUIREMENTS Not Required BENDING The pipe may be bent, but it is not intended for bending made at ambient temperature wherein the inside diameter of the bend is less than twelve times the outside diameter of the pipe being bent. FLATTENING TEST As a test for quality of the weld, position of the weld at 900 from the direction of force and flatten until the OD is 2/3 of the original outside diameter. No cracks shall occur along the inside or outside surface of the weld. DIMENSIONS AND WEIGHTS BLACK PLAIN END Sch. 10 Nominal OD Wall Weight Size Inches Inches LB/FT 1-1/4" 1.660 .109 1.81 1-1/2" 1.900 .109 2.09 2.375 .109 2.64 2-1/2" 2.875 .120 3.53 3.500 .120 4.34 4.500 .120 5.62 6" 6.625 .134 9.30 8" 8.625 .188 16.96 PERMISSIBLE VARIATIONS Minimum wall thickness at any point shall not be more than 12.5% under nominal wall thickness specified. Outside Diameter, NPS 1-1/2" and under, +/-.016". NPS 2" and over +1-1%. PRODUCT MARKING Each length of pipe 1-1/4" NPS and larger is continuously stenciled to show manufacturer, country of origin, grade, type, size, and length, along with UL & FM markings tqCo /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Grinnell Grooved Fire Protection Products Fire Protection Submittal Sheet Listing and Approval Information Page 1 of 8 MARCH 2011 TFP1800 Page 2 of 8 TFPISOO Figure Nominal Size Inches Nominal Size mm i e S h d pe Schedule u Rated Pressure (psi-UL,ULC,FM; Bar LPCB and VdS) 00 1, Figure 705 11/4, 11/2, 2 42.4,48.3,60.3 Sch 5, ID, WST 175 175 175 - 11/4, 11/2,2,21/2 42.4,48.3,60.3, 73.0 Sch 10, Sch 40 300 300 300 - - 3,4,5, 6,8 88.9, 114.3, 141.3, 168.3,219.1 Sch 10, Sch 40 300 300 300 - - 10,12 273.0, 323.9 Sch 10, Sch 40 250 250 250 - - 11/4, 11/2,2,21/2,3 42.4,48.3,60.3,73.0,88.9 MF 300 300 300 - - 4 114.3 MF - - 300 - - 11/4, 11/2,2,21/2,3,4 42.4, 48.3, 60.3, 73.0, 88.9,114.3 DF 300 300 300 - - 11/4, 1V2, 2,21/2,3,4 42.4, 48.3, 60.3, 73.0, 88.9,114.3 FLF 300 300 - - - 11/2, 2,21/2,3,4 48.3, 60.3, 73.0, 88.9,114.3 FF 300 300 300 - - 11/4, 11/2,2 33.7,42.4,48.3, 60.3 MLT, EZT 300 300 300 - - 3 88.9 EZ 300 300 300 - - 4 114.3 EZ 250 250 300 - - 6 168.3 EZ 250 250 175 - - 11/4, 11/2,2 42.4,48.3,60.3 BLT, DI, IL, Gal 7, Gal Flo 300 300 300 - - 11/4,11/2,2 42.4,48.3,60.3 GL, MLT, MI, SL,WLS 300 300 - - - 11/4,11/2,2 42.4,48.3,60.3 UE - - 175 - - 76.1, 165.1 BS1387 300 300 300 - - 42.4, 48.3, 60.3, 76.1, 88.9,114.3 BS1387, ISO 4200 - - - 16 20 139.7 BS1387, ISO 4200 - - - 16 - 165.1 BS1387, ISO 4200 - - - - 20 168.3,219.1 ISO 4200 - - - 16 20 108.0, 133.0, 159.0 ISO 4200 300 - 300 - - 216.3 JIS G3452 300 - 300 - - Figure 707 11/2,2,21/2 48.3,60.3,73.0 Sch 5, yE, WST 175 175 175 - - 11/2,2,21/2,3,4,5 48.3,60.3,73.0,88.9,114.3,141.3 Sch 10 450 450 450 - - 6,8,10,12 168.3, 219.1, 273.0, 323.9 Sch 10 450 450 450 - - 11/2,2,21/2,3,4,5 48.3,60.3,73.0,88.9,114.3,141.3 Sch 40 500 500 500 - - 6,8,10,12 168.3, 219.1, 273.0, 323.9 Sch 40 500 500 500 - - 11/2, 2.21/2,3,4 48.3, 60.3,73.0,88.9, 114.3 MF, DF, FF, SF, STF 300 300 300 - - 2 60.3 EZT 300 - - - - 3 88.9 EZ 300 300 300 - - 4 114.3 EZ 250 250 300 - - 6 168.3 EZ 250 250 175 - - 11/2,2,21/2,3 48.3, 60.3,73.0, 88.9 XL 300 300 300 - - 11/2,2 48.3,60.3 GL, MI, MLT, TL 300 300 300 - - 11/2,2 48.3,60.3 Gal 7, Gal Flo 300 300 300 - - 11/2, 2 48.3, 60.3 BLT, DI - - 300 - - 14,16 355.6,406.4 Sch 30 300 - - - - 18,20 457.2, 508.0 Sch 30 200 - - - - 24 610.0 Sch 20 250 - - - - 76.1, 165.1 BS1387, ISO 4200 - 300 - 20 48.3,60.3,88.9,114.3,168.3 BS1387, ISO 4200 - - - 20 219.1, 273.0,323.9 ISO 4200 L250 - - 16 20 Figure 71 2 60.3 Sch 5, ID, UE, WST 175 175 - - 2,21/2,3,4,5 60.3, 73.0,88.90 114.3,141.3 Sch 10, Sch 40 250 250 - - 6,8 168.3,219.1 Sch 10, Sch 40 250 1 250 250 - - 10,12 273.0, 323.9 Sch 40 250 250 250 - - 2 60.3 BLT, DI, EZT, FF, GL, 15 250 250 250 - - 2 60.3 MI, MIT, TL, WLS, XL 250 250 250 - - 2 60.3 2500 Gal 7, Gal Flo 250 250 250 - - 2 60.3 MF, FF - - 250 - - 2, 21h, 3,4 60.3, 73.0,88.9, 114.3 OF, FF, MF, SF 250 250 - - 3,4 88.9, 114.3 EZ 250 250 250 - - 6 168.3 EZ 250 250 175 - - 2,3,4 60.3,88.9,114.3 STF 250 250 250 - - 21/2,3 73.0, 88.9 XL 250 250 250 - - Figure 71 PN16 60.3, 76.1, 88.9,114.3,168.3 BS1387, ISO 4200 250 - 250 16 20 139.7 B51387, ISO 4200 250 - 250 16 - 165.1 BS1387, ISO 4200 250 - 250 - 20 219.1, 273.0 ISO 4200 250 - 250 - 20 323.9 ISO 4200 250 - 250 - 16 TFP1800 Page 3 of 8 Figure Nominal Size Inches Nominal Size mm Pipe Schedule Rated Pressure (psi-UL,ULC,FM; Bar LPCB and VdS) (U-1) Figure 772 Patented 11/4,11/2,2 42.4,48.3,60.3 Sch 5, ID, UE, WST 175 175 175 - - 11/4 42.4 Sch 10, Sch 40 300 300 300 - - 11/2,2,21/2,3,4 48.3,60.3,73.0,88.9,114.3 Sc1110,Sch40 500 500 500 - - 5,6 141.3, 168.3 Sch 10 300 1 300 300 - - 8 219.1 Sch 10 400 400 400 - - 5 141.3 Sch 40 300 300 300 - - 6 168.3 Sch 40 400 400 400 - - 8 219.1 Sch 40 450 450 450 - - 10,12 273.0,323.9 Sch 10, Sch 40 250 250 250 - 11/4,11/2,2,21/2,3 42.4148.3160.3,73.0,88.9 MF 300 300 300 - - 4 114.3 EZ, MF 250 250 300 - - 3 88.9 EZ 300 300 300 - - 6 168.3 EZ 250 250 300 - - 22 486073881143 DF, STF 300 300 300 1114,11/2,2,21/2,3 42.4148.3160 3,73.0,88.9 FLF 300 300 - 4 114.3 FLF 250 250 - - - 11/2,2,21/2,3 48.3,60.3,73.0,88.9, FF 300 300 300 - - 4 114.3 FF 250 250 300 - - 11/4,11/2,2 42.4,48.3,60.3 EZI, MI, MLT, WLS 300 300 300 - - V/4,11/2,2 42.4,48.3,60.3 GL Gal 7, Gal Flo 300 300 300 - - 11/2,2 48.3,60.3 BLT, DI 300 300 300 - - 11/2,2 48.3,60.3 TI, XL 300 300 - - - 76.1, 165.1 BS1387 300 300 300 - - 424 48.3,60.3,76.1,88.9,114.3 BS1387, ISO 4200 - - - 16 20 139.7 B81387, ISO 4200 - - - 16 - 165.1 B81387, ISO 4200 - - - - 20 168.3,219.1, 273.0,323.9 ISO 4200 - - - 16 20 Figure 716 2X11/2,21/2X2,3X2 60.3 x 48.3,73.0 x 60.3, 88.9 x 60.3 Sch5 175 175 175 - - 3x21/2,42,4x21/2 88.9x73,0,114.3x60,3,114.3x73.0 Sch5 175 175 175 - 2x11/2,21/2x2,3x2 60.3 x 48.3, 73.0 x 60.3, 88.9 x 60.3 Sch lo, Sch 4O 350 350 350 - - 3x21/2,4x2,4x21/2 88.9x73.0,114.3x60.3,114.3x73.0 Sch lo, Sch 40 350 350 350 - - 4x3,5x4 114.3 x 88.9,141.3,114.3 Sch 10,Sch40 350 350 300 - - 6x4,6x5 168.3 x 114.3 x 1638.3 x 141.3 Sch lO, Sch 40 350 350 300 - - 8 x 6 219.1 x 168.3 Sch 40 350 350 300 - - 2 X 11/2, 21/2x 2, 3 x 2 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 DF, EZT, FF, GL, MF 300 300 300 - - 2X1'/2,21/2X2,3X2 60,3x48,3,73.0x60.3,88.9x60.3 MT, MLT, SF, STF, TL 300 300 300 - - 42 114.3x60.3 OF, ElF, FF, GL, MF 300 300 300 - - 42 114.3x60.3 300 ,0 MT, MLT, SF, STF, TL 300 300 300 - - 3X2'/2,4X21/2,4X3 88.9 x 73.0,114.3 x 73.0,114.3 x 88.9 DF, MF, SF 300 300 - - 4X2'/2,4X3 114.3 x 73.0,114.3 x 88.9 FF, STF 300 300 300 - - 5x4,6x4 141.3 x 114.3,168.3 x 114.3 DF, FF, SF,STF 300 300 300 - - U2, 3x21/2 88.9x60.3,88.903.0 EZ 300 300 300 - - 2X11/2 60.3x48.3 Gal 7, Gal Flo 300 300 300 - - 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 851387, ISO 4200 300 - 300 16 20 88.9x76.1,114.3x60.3,114.3x76.1 BS1387, ISO 4200 300 - 300 16 20 114.3x88.9 BS1387, ISO 4200 300 - 300 16 20 168.3 x 114.3,219.1 x 168.3 IS04200 300 - 300 16 20 139.7x114.3 BS1387, ISO 4200 300 1 300 16 165.1 x 114.3 B81387, ISO 4200 300 - 300 - 20 J1 Figure 40-5. 11/4, V/2,2 X '/2,/41 42.4,48.3,60.3 x 21.3,26.7,33.7 Sch 5, Sch 10, Sch 40 175 175 175 - - 11/4, V/2,2 X'/2,/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 BLT, OF, DT, GL, LS, MF 175 175 175 - - 11/4,11/2,2 02,3/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 MI, MLT, IL, WLS, XL 175 175 175 - - 11/4,1V2,2XV2,3/4,1 42.4,48.3,60.3 x 21.3, 26.7,33.7 Gal 7, Gal Flo 175 175 175 - - V/a, 1V2 x 1/2,3/4,1 42.4,48.3 x 21.3,26.7,33.7 ElF 175 175 175 - - 11/2 x 1/2,3/4,1 48.3 x 21.3,26.7,33.7 FF 175 175 175 - - 21 /2X'I2,3/4,1 73.0x21.3,26.7,33.7 Sch 10, Sch 4O 175 175 175 - - 2'/2x 1/2,3/4,1 73.0 x 21.3,26.7,33.7 OF, MF, STF, XL 175 175 175 - - 11/2,2X 1/2,3/4,1 48.3,60.3x21.3,26.7,33.7 STF 175 175 175 - - Figure 40-5 Straps are UL and ULC Listed and FM Approved with NPT and ISO threaded outlets as specified in the chart. Page 4 of 8 TFPI800 Figure g Nominal Size Inches Nominal Size mm Pipe Schedule Rated Pressure (psi-UL,ULC and FM; bar LPCB and VdS) 0 4X21/2 Figure 730 Threaded*1 2 X 1/2, 3/4, 1,11/4, 11/2 60.3 x 21.3, 26.7, 33.7, 42.4, 48.3 Sch 5 175 175 175 - - 2 X 1/2,3/4,1,11/4, 11/2 60.3 x 21.3, 26.7, 33.7, 42.4, 48.3 Sch 10, Sch 40 300 300 300 - - 21/2 X 1/2,3/4,1,11/4,11/2,2 73.0 x 21.3, 26.7,33.7,42.49 48.3,60.3 Sch 10, Sch 40 300 300 300 - - 3,4 x '/,h,1 88.9,114.3 x 21.3, 26.7, 33.7 Sch 10, Sch 40 300 300 300 - - 4X2V2,4X3 114.3 x 73.0,4 x 88.9 Sch 1O, Sch 40 300 300 300 - - 5X2,5X2V2 141.3 x 60.3,141.3 x 73.0 Sch lO, Sch 40 300 300 300 - - 6 x 11/2,2,21/2,3,4 168.3 x 48.3, 60.3, 73.0, 88.9, 114.3 Sch 10, Sch 40 300 300 300 - - 2 x 1/2, 3/4, 1, 11/4, 11/2 60.3 x 21.3, 26.7,33.7,42.4,48.3 BLT, DI, EZ1 FF, GL, MF 300 300 300 - - 2 x 1/2, 3/4, 1, 11/4, 11/2 60.3 x 21.3, 26.7,33.7, 42.4,48.3 MI, MIT, STF, IL, WLS 300 300 300 - - 2 x 1/2, 1/4,11, 11/4, 1V2 60.3 x 21.3, 26.7, 33.7, 42.4, 48.3 Gal 7, Gal Flo 300 300 300 - - 2 x 1/2, 3/4, 1 60.3 x 21.3, 26.7, 33.7 DF 300 300 300 - - 21/2 3,4 x 1/ 3/4 1 730 889 1143 x 21 .3, 267 337 OF FF MF STF 300 300 300 - - 2 x 11/4, 1V2 60.3 x 42.4,48.3 OF 300 300 300 - - 3,4x2 88.9,114.3 x 60.3 DF,FF,MF,STF 300 300 300 - - 114.3x73.0 DF,FF,MF,STF 300 300 300 - - 4x3 114.3x88.9 FF,MF,STF 300 300 300 - - ____________________ 76.1 x21.3, 26.7, 33.7 BS1387, ISO 4200 300 - 300 16 20 139.7 x 48.3, 88.9 BS1387, ISO 4200 300 - 300 16 20 165.1 x 42.4 BS1387, ISO 4200 300 - 300 16 20 60.3 x 21.3, 26.7, 33.7, 42.4, 48.3 B51387, ISO 4200 - - - 16 20 76.1 x 42.4, 48.3, 60.3 B51387, ISO 4200 - - - 16 20 88.9 x 21.3,26.7,33.7,42.49 48.3,60.3 B51387, ISO 4200 - - - 16 20 114.3 x 21.3, 26.7, 33.7, 42.4 B51387, ISO 4200 - - - 16 20 114.3 x 48.31,76.1, 88.9 BS1387, ISO 4200 - - - 16 20 165.1 x 48.3, 60.3, 76.1, 88.9, 114.3 BS1387, ISO 4200 - - - - 20 139.7 x 60.3, 76.1 BS1387, ISO 4200 - - - 16 - 168.3 x 48.3,60.3,73.0 ISO 4200 - - - 16 20 168.3, 219.1 x 76.1, 88.9,114.3 IS04200 - - - 16 20 O Figure 730 Grooved**I 2 x 11/2 60.3 x 48.3 Sch 5 175 175 175 - - 2,21/2,3,4,5,6 x 11/2 60.3,73.0,88.9,114.3,141.3,168.3 x48.3 Sch 10, Sch 40 300 300 300 - - 3,4,5 x 2, 21/2 88.9, 114.3, 141.3 x 60.3, 73.0 Sch 10, Sch 40 300 300 300 - - 4x3,5x3 114.3 x 88.9,141.3 x 88.9 Sch 10, Sch 4O 300 300 300 - - 6 x 21/2,3,4 168.3 x 48.3, 73.0, 88.9,114.3 Sch 10, Sch 40 250 250 250 - - 8 x 21/2,3,4 219.1 x 73.0,88.9,114.3 Sch 10, Sch 40 300 300 300 - - 2,21/2,3,4 x 11/2 60.3, 73.0, 88.9, 114.3 x 48.3 OF 300 300 300 - - 3,4x2 88.9,114.3 x 60.3 OF 300 300 300 - - 2 x 11/2 60.3 x 48.3 BLT, IL 300 300 300 - - 3 X 11/2 88.9 x 48.3 EZ 300 300 300 - - 139.7 x 48.3, 88.9 B51387, ISO 4200 300 - 300 16 20 165.1 x 42.4, 48.3, 60.3, 76.1 B51387, ISO 4200 300 - 300 16 20 60.3 x 42.4, 48.3 BS1387, ISO 4200 - - - 16 20 76.1 x 42.4, 48.3, 60.3 8S1387, ISO 4200 - - - 16 20 88.9 x 42.4,48.39 60.3 B513879 ISO 4200 - - - 16 20 114.3 x 42.4, 48.3, 60.3, 76.1, 88.9 B51387, ISO 4200 - - - 16 20 165.1 x 48.3, 60.3, 76.1, 88.9, 114.3 8S1387, ISO 4200 - - - - 20 139.7 x 60.3, 76.1 8S1387, ISO 4200 - - - 16 - 168.3 x 48.3, 60.3,73.0 ISO 4200 - - - 16 20 168.3, 219.1 x 76.1, 88.9,114.3 ISO 4200 - - - 16 * Figure 730 Threaded Mechanical Outlets are UL and ULC Listed and FM Approved in both the Tee and Cross configuration with NPT and ISO threaded outlets as specified in the chart. ** Figure 730 Grooved Mechanical Outlets are UL and ULC Listed and FM Approved in both the Tee and Cross configuration. 1 Figure 730 Threaded and Grooved Mechanical Outlets are VdS Approved in the Tee configuration only. Grinnell® products are UL and ULC Listed and FM, LPCB and VdS Approved, as specified in the charts, for the pressure ratings shown for use in Fire Protection Systems (automatic sprinkler, open sprinkler and standpipe) and connections to such systems. The charts were developed from the latest Listings and Approval data available at the time of publication. Listings are subject to changes and additions by the approval bodies. For Dry Pipe systems or Freezer Systems, use Td-Seal Gaskets and petroleum free silicone lubricant. Follow installation instructions provided in the Installation Handbook I1-1-1000. TFPISOO Page 5 of 8 Figure Nominal Size Inches Nominal Size mm Pipe Schedule Rated Pressure (psi-UL,ULC,FM; Bar LPCB end VdS) - To - - - Figure 577 1-1/4,1-1/2,2 42.4,48.3,60.3 FLF, MF, XL, GL, 10, 40, CT, DF,TL, WLS, MT, MLT 300 300 300 2-1/2,3,4 73.0,88.9,114.3 FLF,MF,DF 300 300 300 - - 2-1/2,3 73.0,88.9 FF, XL 300 300 300 - - 1-1/4,1-1/2,2, 2-1/2,3,4,6,8 42.4, 48.3, 60.3, 73.0, 88.9, 114.3, 168.3, 219.1 10 300 300 300 1-1/4,1-1/2,2, 2-1/2,3,4,6 42.4, 48.3, 60.3, 73.0, 88.9, 114.3, 168.3 40 300 300 300 1,1-1/4,1-1/2,2 33.7,42.4,48.3, 60.3 5 175 175 175 3,4,6 88.9, 114.3,168.3 EZF 300 300 300 - - 11/4 42.4 EZT 300 300 300 - - 1-1/2,2 48.3,60.3 EZT, FF 300 300 300 - - 1-1/2,2,2-1/2,3,4 48.3,60.3,73.0,88.9,114.3 STF 300 300 300 - - 4 114.3 STF 250 250 250 8 219.1 0.188 in. wall 300 300 300 _________________ 33.7 ___________________________ 10, 40, XL, TL, OF, BLT, DL, DI, MI, WLS,WST, GL,MLT,EZI, ET, EL, 5, BS1387M, ISO 4200 300 - 300 - 300 - - - 5 141.3 10 300 300 300 - - 5 141.3 40 300 300 300 76.1 mm, 165mm BS1387M, ISO 4200 300 300 139.7mm ISO 4200 300 300 1,1-1/4,1-1/2,2,3,4 33.7,42.4,48.3,60.3,88.9,114.3 BS1 387M, ISO 4200 20 bar 76.1, 165.1 BS1387M, ISO 4200 20 bar 6,8 168.3, 219.1 ISO 4200 20 bar 1,1-1/4,1-1/2,2,3, 4,6,8 33.7,42.4,48.3,60.3,88.9,114.3, 168.3, 219.1 ISO 4200 16 bar 76.1,139.7 1S04200 16 bar Pipe Schedule Key STF - Steady Flow Listed/Approved steel sprinkler pipe manu- factured by AMS Tube Corp. BLT - Black Light Wall Threadable Listed/Approved steel sprin- kler pipe manufactured by Allied Tube and Conduit. DF - Dyna-Flow Listed/Approved steel sprinkler pipe manufac- tured by Allied Tube and Conduit. DT - Dyna-Thread Listed/Approved steel sprinkler pipe manu- factured by Allied Tube and Conduit. SF - Super-Flow Listed/Approved steel sprinkler pipe manu- factured by Allied Tube and Conduit. XL - Extra Light Weight Listed/Approved steel sprinkler pipe manufactured by Allied Tube and Conduit. UE - Ultra-Eddy Listed/Approved steel sprinkler pipe manufac- tured by Bull Moose Tube Company. TL - TL Listed/Approved steel sprinkler pipe manufactured by Central Grooved Piping Products. LS - Listed/Approved steel sprinkler pipe manufactured by Century Tube Corporation. ID - DOD Listed/Approved steel sprinkler pipe manufactured by IDOD Systems. GAL-FLO - Listed/Approved steel sprinkler pipe manufactured by IDOD Systems. GAL-7 - Listed/Approved steel sprinkler pipe manufactured by IDOD Systems. EZ - EZ-Flow Listed/Approved steel sprinkler pipe manufac- tured by Northwest Pipe and Casting Company. FLF - Fire Line Flow Listed/Approved steel sprinkler pipe man- ufactured by Western International Forest Products. MF - Mega Flow Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. MLT - Mega Light Listed/Approved steel sprinkler pipe manu- factured by Wheatland Tube Company. MT - Mega Thread Listed/Approved steel sprinkler pipe manu- factured by Wheatland Tube Company. SL - Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. WLS - WLS Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. WST - WST Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. GL - GL Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. EZT - EZ Thread Listed/Approved steel sprinkler pipe manu- factured by Youngstown Tube Company. FF - Fire-Flo Listed/Approved steel sprinkler pbe manufac- tured by Youngstown Tube Company. 5 - Schedule 5 steel sprinkler pipe 10 - Schedule 10 steel sprinkler pipe 20 - Schedule 20 steel sprinkler pipe 30 - Schedule 30 steel sprinkler pipe 40 - Schedule 40 steel sprinkler pipe BS1387m - British Standard Medium Listed/Approved steel sprinkler tube. 1S04200 - ISO Standard Listed/Approved steel sprinkler tube. JIS G3452 - Japanese International Standard Note: Cut and roll grooved references are for pipe runs and also grooved outlets. Page 6 of 8 Figure ADACAPO Figure 201 450 Elbow Figure 210 90° Elbow Figure 219 - Tee 4.4 Figure 260 End Cap Fb - TW1I4pI cL Figure 250 Concentric Reducer TFPI 800 Figure Nominal Size Inches Nominal Size mm Rated Pressure (psi-UL,ULC,FM; Bar LPCB and VdS) Ji <> i ADACAP®* 1'/2 X'/2,'/4,1 42.4 x 21.3, 26.7, 33.7 300 300 300 - - 2 X 1/2 3/4, 1 48.3 x 21 .3, 26.7,33.7 300 300 300 - - 21/2 X 1/2, 3/4, 1 60.3 x 21.3, 26.7, 33.7 300 300 300 - - Figure 201 1 33.7 500 500 500 - - 11/4, 11/2,2,3,4 42.4, 48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3, 219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 12 323.9 450 450 400 16 20 21/2, 5 73.0, 141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 139.7 500 - 500 16 - 108.0,133.0,159.0, 216.3 300 300 - - Figure 210 1 33.7 500 500 500 - - 11/4,11/2,2,3,4 42.4, 48.3, 60.3, 88.9,114.3 500 500 500 16 20 6,8 168.3, 219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 12 323.9 450 450 400 16 20 21/2,5 73.0, 141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 139.7 500 - 500 16 - 108.0,133.0,159.0, 216.3 300 - 300 - - Figure 219 1 33.7 500 500 500 - - 11/4, 1'/2, 2,3,4 42.4, 48.3, 60.3, 88.9,114.3 500 500 500 16 20 6,8 168.3, 219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 12 323.9 450 450 400 16 20 21/2,5 73.0,141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 139.7 500 - 500 16 - 108.0,133.0,159.0,216.3 300 - 300 - - Figure 260 11/4,11/2,2,3,4 42.4, 48.3, 60.3, 88.9,114.3 500 500 500 16 20 6,8 168.3, 219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 12 323.9 450 450 400 16 20 2V2,5 73.0, 141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 139.7 500 - 500 16 - Figure 250 11/2, xl, 2 x 48.3 x 33.7, 60.3 x 33.7 500 500 500 16 - 2 x 11/4,2 x 11/2 60.3 x 42.4, 60.3 x 48.3 500 500 500 16 20 21/2 X 2,3 x 21/2,4 x 21/2 73.0 x 60.3, 88.9 x 73.0, 114.3 x 73.0 500 500 500 16 20 4 x 2,6 x 2 114.3 x 60.3, 168.3 x 60.3 500 500 500 16 - 3x2,4x3,6x4 88.9 x 60.3,114.3 x 88.9,168.3 x 114.3 500 500 500 16 20 5 x 4,6 x 5 141.3 xli 4.3, 168.3 x 141.3 500 500 500 - - 76.1 x 48.3, 76.1 x 60.3 500 500 500 16 20 88.9x76.1, 114.3x76.1 500 500 500 16 20 139.7x88.9, 139.7x114.3 500 500 500 16 - 165.1x114.3 500 500 500 - 20 168.3 x76.1, 168.3x139.7 500 500 500 16 - 165.1 x88.9, 165.1 x139.7 500 - 500 - - * ADACAPs are UL and ULC Listed and FM Approved with NPT and ISO threaded outlets. Figure Nominal Size Inches Nominal Size mm Rated Pressure (psi-UL,ULC,FM; Bar LPCB and VdS) Figure 501 11/4,11/2,2,3,4 42.4, 48.3, 60.3, 88.9, 114.3 300 300 300 16 20 6,8 168.3,219.1 300 300 300 16 20 21/2,5 73.0, 141.3 300 300 300 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 510 11/4,1V2,2,3,4 42.4,48.3,60.3,88.9,114.3 300 300 300 16 20 6,8 168.3,219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 519 11/4, 11/2, 2, 3, 4 42.4,48.3,60.3, 88.9,114.3 300 300 300 16 20 6,8 168.3,219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 2,3,4,6,8 60.3, 88.9,114.3,168.3, 219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 2,3,4,6,8 60.3, 88.9,114.3,168.3,219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 2,3,4,6,8 60.3, 88.9,114.3, 168.3, 219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - - 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Figure 510DE 21/2,3,4,5 73.0, 88.9, 114.3, 141.3 300 300 300 - - 6,8 168.3,219.1 300 300 300 - - Figure 501 45° Elbow Figure 510 90° Elbow Figure 519 - Tee Figure 501S 45° Elbow Figure 510S 90° Elbow I Figure 519S Tee TFPI 800 Page 7 of 8 Figure 511 Drain Elb TFPI800 Fabricated Fittings Figure Nominal Size Inches Rated Pressure (psi) Figure 391 Groove x Male Threaded Adapter Nipples 1,11/4,1% 300 300 2,2% ____________ 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 392 Groove x Groove Adapter Nipples 1,1V4,1Y2 300 300 2,2% 300 300 ____________ 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 393 Groove x Bevel Adapter Nipples 1,1¼,1% 300 300 2,2% 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 312 22½0 Elbow 1%,1½ 300 300 2,2% 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 313 111/4° Elbow 1%,1½ 300 300 2,21/2 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Page 8 of 8 Figure Nominal Size Inches Rated Pressure (psi) Figure 321 Reducing Tee 11/4,1% 300 300 2,21/2 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 327 Cross 1,11h,1½ 300 300 2,21/2 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 341 Groove Flange Adapter 150 lbs. 1,114,1% 300 300 2,21/2 300 300 3,4,5 300 300 6,8 300 300 10,12 300 300 Figure 350 Concentric Groove x Groove Reducer 114,1% 300 300 2,21/2 300 300 3,4, 5 300 300 6,8 300 300 10,12 300 300 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to en- ISO sure that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (11-1-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 ii:1A1 - -ii11iIIiIiIiIC- rI!rl Threaded Fittings Tyco Fire Products --- www.tyco-grooved.com EENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700/ Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Description ® See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information Ductile Iron threaded fittings (with the exception of California Tees and Street Elbows) conform to ANSI 1316.3. They are higher in strength and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties making up the fitting. This is accomplished by adding magnesium while the iron is being poured into it final cast shape. This provides an advantage as the fittings are not as susceptible to leaks or cracking and they are also lighter than standard cast iron. Caution: Installers who have not used ductile iron threaded fittings before should be instructed that the fittings are stronger than the pipe and over- tightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-hay turn difference between cast iron and ductile iron fittings. Apply Teflon tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If you are using an automatic make-on machine, please exercise caution in setting your machine to the proper parameters prior to tightening fittings onto the male pipe threads. Technical Data Figures: 811, 812, 813, 814, 815, 816, 817, 818, 820, 825, 827, 830, 719, California Tees, and Street Elbows Sizes: 1/2 - 21/2" Maximum Working Pressure: 800 Series, California Tees, and Street Elbows: 300 psi Figure 719: 250 psi Approvals: UL, and FM Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Manufacture Source: Imported Material: Ductile Iron, conforming to ANSI B16.3 (Note: Figure 719 Plugs are constructed of Cast Iron) Thread: N.P.T. rA Installation Apply Teflon Tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. (See caution in first column) fl Ordering Procedure Ordering information: When placing an order, indicate the full product name. Please specify the quantity, figure number and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, though a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and 171 Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 21-3.0 Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 11/8 /16 86206 0.24 240 3/4 1/16 3/4 86205 0.40 120 1 11/2 13/16 86200 0.64 70 11/4 1/4 11/16 86201 0.95 40 11/2 115/16 13/16 86202 1.24 30 2 21/4 11/2 86203 1.74 20 21/2 211/16 1/l6 86204 3.28 10 ft4 Figure 815 Reducing Tee Figure 811 900 Elbow Figure 812 90° Reducing Elbow fr - 6-- -. I j Size Inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Uty, 3/4 X 1/2 1/16 1/16 5/ 5/ 86342 0.33 160 1XV2 11/4 1/s /16 13/16 86210 0.44 110 1 X3/4 1 1/8 1 /16 1 11/16 7/ 86211 1 0.53 90 11/4 X 1/2 15/16 11/2 5/ 15/16 86212 0.64 75 11/4 x3/4 17/16 1/8 3/4 11/16 86213 0.75 60 11/4 X I 1/16 ifl/is 7/ 1 86214 0.77 55 11/2x3/4 11/2 1/4 3/4 1/16 86221 0.95 45 11/2x1 15/8 113/16 7/ 11/s 86215 0.99 40 11/2X11/4 113 /16 1/8 li/s 13/16 86216 1.14 35 2X 3/4 1/s 115/16 7/ la /s 86217 1.39 30 2 x 1 1/4 21/16 2 1/16 86218 1.58 25 2 X 11/2 2 2/16 11/4 1/16 86220 1.67 20 21/2 X2 23/8 2/8 11/4 17/s 86262 3.01 15 Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 7/ 3/ 86780 0.22 250 3/4 7/16 86781 0.33 150 1 11/8 13/16 86280 0.48 90 11/4 1/16 5/ 86281 0.73 50 11/2 1/16 11/16 86282 0.93 35 2 1hi/16 15/16 86283 1.55 18 21/2 115/16 1 86782 2.70 12 Figure 813 45° Elbow Size Inches A Inches B Inches Part Number Weight Lbs. Box Oty. 1/2 li/s s/is 86340 0.33 150 3/4 1/16 3/4 86341 0.50 90 1 11/2 13/16 86230 0.85 60 11/4 1/4 11/16 86231 1.30 35 11/2 115/16 1/1s 86232 1.63 24 2 21/4 11/2 86233 2.63 12 21/2 211/16 1 /16 86234 4.55 8 Figure 814 Tee h-A I D Size Inches A Inches B Inches C Inches D Inches E Inches F Inches Part Number Wt. Lbs. Box Qty. 3/4x3/4x1/2 13 /16 13/ 16 11/4 5/ 5/ il/is 86235 0.46 95 3/4 x3/4x1 1/16 1/16 la/s 7/ 7/ 11/16 86755 0.68 65 1x1/2 x1 11/2 1/8 11/2 13/16 13/16 13/16 86236 0.70 55 I X 3/4 X 1/2 11/4 1/16 13/8 s/is 5/ 13/16 86756 0.63 80 1 x 3/4 x3/4 1/8 1/16 1/16 li/is 3/4 7/ 86757 0.68 65 1x3/4 x1 11/2 1/16 11/2 13/15 7/ 13/ 16 86237 0.77 55 1 x 1 x 1/2 11/4 11/4 1/8 s/is s/is 13/16 86238 0.66 65 1 x 1 x 3/4 is/s 1/8 17/16 li/16 11/16 7/ 86239 0.73 60 I X x 11/4 111/16 111/16 1/i6 I I 7/ 86240 0.97 45 1 x x 11/2 113/16 113/16 1/8 11/8 11/8 7/ 86241 1.14 35 11/4X1 X1/2 115/16 11/4 1/16 5/ 8/16 1 86242 0.81 50 11/4x1x3/4 1/16 13/8 1/8 3/4 il/16 11/16 86243 0.90 50 11/4x1 X is/is 11/2 1/1s 1/ 13/16 1 86244 1.03 45 11/4x1 x11/4 1/4 Ifl/is 1/4 11/16 1 V/is 86245 1.10 40 11/4x1x11/2 1/8 113/16 1 '3/16 1/16 11/8 11/16 86246 1.43 30 11/4x11/4 x1/2 1/8 1/8 19/16 11/16 Il/is 1 86247 0.87 45 1 '/4x11/4X3/4 17/16 1/16 la/s 3/4 3/4 11/16 86248 0.96 45 11/4x11/4x1 19/16 1/16 1/i6 7/ 7/ 1 86249 1.10 40 11/4X11/4X11/2 1/s 1/8 113/16 113/16 113/16 11/16 86250 1.50 30 11/4x11/4x2 21/s 21/8 2 1/is 1/l6 11/s 86251 2.00 24 11/2 x1 x1/2 i/s 1/16 111/16 "/16 5/ V/s 86252 0.97 40 11/2 x1x3/4 11/2 13/8 1/4 3/4 11/16 13/16 86253 1.14 40 V/2X1X1 1/8 11/2 113/16 7/ 13/16 V/s 86254 1.14 30 V/2x1x11/2 115/16 113/16 115/16 1/16 11/8 li/is 86255 1.52 30 11/2X11/4X1/2 l/s 1/16 111/16 11/16 5/ 11/8 86257 1.03 40 11/2X11/4 X 3/4 11/2 1/16 1/4 3/4 3/4 1/6 86258 1.10 40 11/2x11/4x1 1/s 1/16 113/1s 7/ 7/ 11/8 86259 1.31 30 11/2 x 1/4x 2 2/16 21/5 2 17/ 1 l/s 11/4 862601 1.94 20 11/2X1I/2XI/2 17/16 17 116 111/16 11/16 11/16 il/s 86261 1.14 35 11/2x11/2x3/4 1 '/2 11/2 1/4 3/4 3/4 13/ 16 86262 1.23 35 11/2X1V2X1 15/8 1/8 113/16 7/ 7/ 11/8 86263 1.38 30 11/2x 1V2X 11/4 113/16 113/16 1/8 11/16 11/16 1/16 86264 1.50 30 11/2x11/2x2 2/16 2/16 2 1/16 17 /16 11/4 86265 2.00 20 2x1x2 21/4 2 21/4 11/2 1/16 11/2 86266 2.18 15 2x11/4x 2 21/4 21/s 21/4 11/2 1/16 11/2 86267 12.31115 2x11/2x1/2 11/2 1/16 17/8 3/4 11/16 1/16 86268 1.50 30 2x11/2x3/4 15/s 11/2 115/16 T/ 3/4 is/s 86269 1.61 25 2x11/2x1 1/4 15/8 2 1 7/ 1/16 86270 1.65 20 2x11/2x11/2 21/16 1 5/16 2/16 1/16 1/16 1/s 86272 2.03 20 2x 11/2x2 21/4 2/16 21/4 11/2 17/ 16 11/2 86273 2.37 15 2 x 2 x 1/3 11/2 11/2 1/8 3/4 3/4 15/16 86222 1.50 30 2x2x3/4 1/8 15/8 115/16 7/ 7/ 1/s 86223 1.67 20 2x2x1 1/4 1/4 2 1 1 1/16 86224 1.91 20 2x2x11/4 1/8 1/s 21/s 11/8 11/8 1/16 86225 2.05 20 2x2x11/2 2 2 2/16 11/4 1 '/4 11/2 86226 2.11 15 2x2X21/2 2/8 2/8 2/8 1/4 1/8 1/16 86227 3.67 10 21/2x2x3/4 1/4 li/s 2/16 5/ 7/ 1/4 186274 2.22115 -2- Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 3/4 x 1/2 1/4 11/16 86772 0.38 240 I X /2 1/16 1/2 86228 0.38 200 I X 3/4 1/4 1/2 86229 0.53 110 Figure 825 Extension Piece Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 X 11/2 11/2 72751 0.20 300 1/2 x2 2 72980 0.27 250 3/4 x 11/2 11/2 72981 0.22 250 3/4 x2 1 2 1 72982 1 0.31 200 Figure 816 Reducing Coupling Size Inches A Inches Part Number Weight Lbs. Box Oty. 1/2 /8 72776 0.15 500 3/4 1 72777 0.22 300 1 1 /16 72824 0.33 180 11/4 1/16 72756 0.54 110 11/2 1/8 72822 0.68 80 2 11/2 72823 0.96 45 21/2 1/4 72825 1.80 25 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 15/16 86292 0.10 500 3/4 11/8 86293 0.18 300 1 11/4 86294 0.28 200 11/4 127a 86295 0.50 110 11/2 1/16 86296 0.70 80 2 11/2 86297 0.90 45 Figure 820 Cap Figure 719 Cast Iron Plug Figure 817 Cross Figure 827 Hex Bushing Size Inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Qty. 1 11/2 11/2 13/16 13/15 86284 0.97 45 11/4 1/4 1/4 11/16 11/16 86285 1.59 25 11/2 115/16 115/16 13/ 16 1/16 86286 1.89 20 2 21/4 21/4 11/2 11/2 86287 2.93 10 11/4 X 11/4 X 1 X 1 111/16 19/16 1 /8 86289 1.25 30 11/2 X11/2X1X1 113/16 1/8 11/16 115/16 86322 1.48 24 2 x 2 x 1 x 1 2 1/4 11/4 11/16 86291 2.64 10 Size Inches A Inches Part Number Weight Lbs. Box Qty. I x 11/16 72726 0.22 280 I x 3h 11/16 72762 0.18 280 11/4 X I 1/16 72763 0.31 150 11/2 x 1 11/4 72757 0.53 100 11/2x11/4 11/4 72764 0.35 100 2 x 1 1/s 72759 0.75 80 2x1V4 1/8 72761 0.69 80 71 2 1/2 1/8 72775 0.62 80 Figure 818 B A Straight Coupling - jj Size Inches A Inches B Inches Part Number Wrench Weight Lbs. Box Qty. 1/2 1/8 /16 72779 11/8 0.18 360 3/4 1/8 /1 72778 1/s 0.26 200 1 1/4 3/8 72755 111/16 0.44 110 11/4 2 s/16 72754 2 0.54 75 11/2 2/16 3/4 72753 21/4 0.71 60 2 2/8 11/8 72752 2/4 1.15 30 21/2 3 3/4 72758 3/8 2.29 18 Figure 830 E____________ Brass Seat Union 1 [rlr1 Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 1/ 13/16 86207 0.47 110 3/4 2 15/16 86275 0.66 80 1 2/16 13/16 86276 1.08 50 11/4 21/2 11/16 86277 1.54 35 11/2 2/8 1/16 86278 2.03 25 2 31/8 1/8 86279 3.15 18 -3- Street Elbows F -A - A California Tees [ Size Inches A Inches B Inches C Inches Part Number Weight lbs. Box Qty. 1 X 1/2 11/2 3/4 3 42003 0.70 80 I X 1 11/2 3/4 3 42002 0.90 60 Size Inches A Inches B Inches C Inches D Inches Part Number Weight lbs. Box Oty. 1 x V2 X 1 1V2 7/ 3 3/4 42000 0.95 50 1 X I X 1 11/2 3/4 3 3/4 42001 0.95 45 I Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. '.H 1F(ELiCCThPjN1 tq'co/Flow Control/ Tyco Fire Printed U.S.A. 10-01 Products Model G5 OR Gasket Model G5 SR Gasket Cover Plate Cover Plate Model G5 Series Sprinkler Cover Plates Bulletin 034 May 2019 Reliable111111E R Model G5 Series Sprinklers Standard Spray, Flat Concealed Pendent Available with Solid, Perforated, or Gasket Cover Plate Features Standard Coverage, Concealed Pendent (K2.8, 4.2, 5.6, & 8.0 [40, 60, 80, & 115 metric]) Flat concealed cover plate available solid or perforated in a variety of finishes. Available with Stainless Steel Clad cover plate (see Table I). 3/4-inch (19 mm) cover plate adjustment. Cover plate available with optional gasket. Product Description Model G5 series sprinklers are standard coverage, flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets. The sprinklers are offered with a standard Model G5 cover plate (solid or perforated), a Model G5 cover plate with a Quick-response (OR) gasket, or a Model G5 cover plate with a Standard-response (SR) gasket. Model G5 sprinklers must only be used with the Model G5 cover plate listed or approved with the sprinkler. All Model G5 series sprinklers use a fusible-link operating element. Table A provides a summary of available Model G5 series sprinklers, along with Listing and Approval in- formation for each sprinkler and cover plate combination. ------------- Model G5 Cover Plate Model G5 Cover Plate (Solid) (Perforated) Model G5 Series Sprinkler Summary Sprinkler Model K-Factor gpm/psi112 (LImin/bar1 ) Cover Plate Model Listings and Approvals Sensitivity Max. Working Pressure psi (bar) Sprinkler Identification Number (SIN) G5-28 2.8 (40) G5 cULus OR 175(12) RA3411 FM SR G5 OR Gasket cULus OR G5 SR Gasket cULus, FM SR - G5 42 4.2 (60) G5 cULus OR 175 (12) SR RA3413 G5 OR Gasket G5 SR Gasket cULus G5 ____________ cULus OR 250 (17) FM, LPCB, VdS, CE SR 175 (12) G5-56 5.6 (80) RA3415 G5 OR Gasket cULus OR 250 (17) G5 SR Gasket cULus SR 250 (17) 175 (12) FM SR G5-56 300 5.6 (80) G5 cULus OR 300 (21) SR RA4014 G5 OR Gasket G5 SR Gasket cULus -80 G5 80 8.0 (115) G5 cULus OR 175 (12) SR RA3412 G5 OR Gasket G5 SR Gasket cULus G5-80F 8. 0 (115) G5 FM SR G5 SR Gasket 175 (12) RA3417 www.reliablesprinkler.com 3/16" (5 mm) Threads Body Cup Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) -t Ceiling 3/4(19 mm) Max, Cover Plate Adjustment ri Technical Specifications Style: Flat Concealed Pendent Threads: /2 NPT or ISO 7-1 R1!2 Nominal K-Factor 2.8 (40 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Fusible Link: Beryllium Nickel Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing washer: Nickel with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sprinkler Temperature Ratings 165°F (74°C) 212°F (100°C) Sensitivity (See Table B) Cover Plates Model G5 (Solid or Perforated) Model G5 OR Gasket (cULus only) Model G5 SR Gasket Cover Plate Finishes (See Table I) Sprinkler Wrench Model FC Listings and Approvals cULus Listed (Light Hazard only) FM Approved Model G5-28 Sprinkler Components and Dimensions r!Lui' 2-5/16" (58 mm) Dia. Model G5 Cover Plate 3-5/16" (84 mm) Dia. Ceiling Model G5-28 Sprinkler Sensitivity Cover Plate Model Listing or Approval Agency cULus FM G5 OR SR G5 OR Gasket OR G5 SR Gasket SR SR UN: uuicK-response SR: Standard-response Bulletin 034 02, ,Page 2 of 9 May 2019 www.reiiabiesprinkier.com Technical Specifications Style: Flat Concealed Pendent Threads: /2 NPT or ISO 7-1 R1!2 Nominal K-Factor: 4.2 (60 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Fusible Link: Beryllium Nickel Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing washer: Nickel with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sprinkler Temperature Ratings 165°F (74°C) 212°F (100°C) Sensitivity (See Table C) Cover Plates Model G5 (Solid or Perforated) Model G5 OR Gasket Model G5 SR Gasket Cover Plate Finishes (See Table I) Sprinkler Wrench Model FC Listings and Approvals cULus Listed (Light Hazard only) Model G5-42 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) -40c4' Ceiling 3/4(19mm) Max. Cover Plate Adjustment 3/16(5mm) Model G5 Cover Plate 3-5/16" (84 mm) Dia. Ceiling Model G5-42 Sensitivity Cover Plate Model Listing or Approval Agency cULus G5 OR G5 OR Gasket OR G5 SR Gasket SR JH: Quick-response SR: Standard-response Bulletin 034 Page 3 of 9 May 2019 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 Ri!2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Fusible Link: Beryllium Nickel Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing washer: Nickel with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sprinkler Temperature Ratings 165°F (74°C) 212°F (100°C) (cULus, NO, LPCB, CE only) Sensitivity (See Table D) Cover Plates Model G5 (Solid or Perforated) Model G5 QR Gasket (cULus only) Model G5 SR Gasket (cULus and FM only) Cover Plate Finishes (See Table I) Sprinkler Wrench Model FC Listings and Approvals cULus Listed (Light & Ordinary Hazard only) FM Approved LPCB Approved VdS Approved [165°F (74°C) only] CE Listed Model G5-56 Sprinkler Components and Dimensions s1uIIC 2-5/16" (58 mm) Dia. Threads Body Cup Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) Ceiling 3/4(19 mm) Max. Cover Plate Adjustment 3/16" (5 mm) Model G5 Cover Plate 3-5/16" (84 mm) Dia. Ceiling Model G5-56 Sensitivity Cover Plate Model Listing or Approval Agency cULus FM LPCB, VdS, CE G5 OR SR SR G5 OR Gasket OR -- -- G5 SR Gasket SR SR -- UK: uulck-response SR: Standard-response Bulletin 034 Page 4 of 9 May 2019 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2 NPT or ISO 7-1 RI!2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 300 psi (21 bar) Material Specifications Fusible Link: Beryllium Nickel Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing washer: Nickel with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sprinkler Temperature Ratings 165°F (74°C) 212°F (100°C) Sensitivity (See Table E) Cover Plates Model G5 (Solid or Perforated) Model G5 OR Gasket Model G5 SR Gasket Cover Plate Finishes (See Table I) Sprinkler Wrench Model FC Listings and Approvals cULus Listed (Light & Ordinary Hazard only) Model G5-56 300 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Tower Fusible Link Deflector (retracted) Pin (extended) H Deflector (extended) Ceiling I 3/4" (19 mm) Max. Cover Plate Adjustment 3/16" (5 mm) Model G5 Cover Plate 3-5/16" (84 mm) Dia Ceiling Model G5-56 300 Sensitivity Cover Plate Model Listing or Approval Agency cULus G5 OR G5 OR Gasket OR G5 SR Gasket SR UI-c: uulcK-response SR: Standard-response Bulletin 034 Rel Page 5 of 9 May 2019 M&M www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 8.0 (115 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Fusible Link: Beryllium Nickel Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing washer: Nickel with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sprinkler Temperature Ratings 165°F (74°C) 212°F(1000C) Sensitivity (See Table F) Cover Plates Model G5 (Solid or Perforated) Model G5 OR Gasket Model G5 SR Gasket Cover Plate Finishes (See Table I) Sprinkler Wrench Model FC Listings and Approvals cULus Listed (Light & Ordinary Hazard only) Model G5-80 Sprinkler Components and Dimensions _F•LultI_ 2-5/16" (58 mm) Dia. Threads Body Cup Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) -tc ' Ceiling 3/4(19 mm) Max. Cover Plate Adjustment Model c5 Cover Plate 3/16(5 mm) 3-5/16" (84 mm) Dia. Ceiling Model G5-80 Sensitivity Cover Plate Model Listing or Approval Agency cULus G5 OR G5 OR Gasket OR G5 SR Gasket SR OH: Ouick-response SR: Standard-response Bulletin 034 Page 6 of 9 May 2019 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 8.0 (115 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Fusible Link: Beryllium Nickel Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing washer: Nickel with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Stainless Steel Cup: Steel Sprinkler Temperature Ratings 165°F (74°C) 212°F (100°C) Sensitivity Standard Response Cover Plates Model G5 (Solid or Perforated) Model G5 SR Gasket Cover Plate Finishes (See Table I) Sprinkler Wrench Model FC Listings and Approvals FM Approved Model G5-80F Sprinkler Components and Dimensions 2-5/16 (58 mm) Dia. Threads Body Cup Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) Ceiling 3/411(19 mm) Max, Cover Plate Adjustment 3/16 (5 mm) Model G5 Cover Plate 35/16h1 (84 mm) Dia Ceiling Model G5-80F Sensitivity Cover Plate Model Listing or Approval Agency FM G5 SR G5 SR Gasket SR bh: Tanoara-response Bulletin 034 Page 7 of 9 May 2019 Rellabld www.reliablesprinkler.com Installation Dimensions and Cover Plate Information Mm. to Max. Mm. to Max. Cover Plate Recommended Cover Plate Face of Fitting Dropped Cover Plate Cover Plate Diameter Hole Diameter Adjustment to Deflector Temperature Model Inch in Ceiling Inch Ceiling 1) Distance Rating (mm) Inch (mm) Inch below Ceiling OF (mm) (mm) Inch (°C) (mm) G52 3-/16 (84) 2-5/o (67) 3/4 (19) 1 1/2 to 2-1/4 (38 to 57) 1/4 to 1 (6 to 25) 4 135°F (57°C) or G5 OR Gasket(3) 311/1 (94) G5 SR Gasket(3)4 (101 mm) 165°F5 (74°C) Notes: Face of fitting to ceiling dimensions are based on nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2 brass nipple extension (Reliable P/N 6999991900) is available to assist with replacement of Reliable Model G4A sprinklers. Model G5 cover plates are available either solid or perforated. Model G5 OR Gasket and Model G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket. Model G5 OR Gasket and Model G5 SR Gasket cover plates and gaskets are not interchangeable. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (380C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C). Cover Plate Finishes'1 Standard Finishes Special Application Finishes White Paint Off-White Paint Chrome Black Paint Custom Color Paint - Specify 2) Raw Brass (Lacquered) Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Application Model G5 series sprinklers are standard coverage, flat plate concealed pendent sprinklers. The sprinklers are intended for use in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets, as well as the requirements of the applicable approval agencies. Model G5 series sprinklers are available as either Quick-re- sponse (OR) or Standard-response (SR) depending on the approval agency and cover plate selected. Model G5 series sprinklers use Model G5 flat cover plates. Model G5 OR Gasket and G5 SR Gasket cover plates are available to limit air and dust movement through the ceiling. Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Gaskets for Model G5 OR Gasket and Model G5 SR Gasket cover plates are only available in white. Custom color paint is semi-gloss unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Listing & Approval Agencies Individual Model G5 series sprinkler may be listed or ap- proved by the following agencies: Underwriters Laboratories, Inc. and UL Canada (cULus) Listing Category: Sprinklers, Automatic and Open Guide Number: VNIV FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) EC-Certificate of Conformity 0832-CPD-2062 (CE) See Table A and the individual sprinkler data sheets in this Bulletin for listings and approvals applicable to each sprinkler. Bulletin 034 Page 8 of 9 May 2019 www.reliablesprinkler.com Installation Model G5 series sprinklers are intended to be installed in accordance with NFPA 13, FM Global Property Loss Prevention Data Sheets, and the requirements of other applicable authorities having jurisdiction. Model G5 series sprinklers must not be installed in ceilings with positive pressure in the space above. Model G5 series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model G5 series sprinkler are installed with the Model FC wrench. The use of any other wrench to installed Model G5 series sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is specified in Table J. Installation Torque Recommended Installation Torque Sprinkler Threads (mm. - max.) ft.lb I N.m ½" NPTor 1S07-1R1/2 8-18 I 11-24 3/4" NPTor 1S07-1R3/4 14-20 I 19-27 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand, turning the cover in the clockwise direction until it is tight against the ceiling. For Model G5 OR Gasket and Model G5 SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt only. Do not glue the gasket in place or allow the gasket to overlap both the cover plate and the flange of the skirt. Maintenance Reliable Model G5 series sprinkler should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler or cover plate which has been painted (other than factory applied). Properly installed Model G5 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Model G5 series sprinklers have holes in the cup that must remain unobstructed. Replace any sprinkler which has been damaged. A stock of spare sprinklers should be maintained to allow quick re- placement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model G5 series sprinklers may be covered by one or more of the following patents: U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent 8,776,903, U.S. Patent 9,248,327 Ordering Information Specify the following when ordering. Sprinkler Model [G5-28] [G5-42] [G5-56] [G5-56 300] [G5-80] [G5-80F] Temperature Rating [165°F (74°C)] [212°F (100°C)] Threads [NPTor ISO 7-11 Cover Plate Model [G5 (Solid), G5 Perforated, G5 OR Gasket, G5 SR Gasket] Finish (See Table I) Sprinkler Wrench Model FC Model FC Wrench c'J Q N-C) C) C) C) C) IN Bulletin 034 Page 9 of 9 May 2019 www.reliablesprinkler.com Upright Pendent Vertical Sidewall Horizontal Sidewall Bulletin 014 March 2019 R,a eIb 0 k Model Fl FR Series Quick Response Glass Bulb Sprinklers Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSl/UL199. FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model F1FR series sprinklers / \ are quick-response automatic sprin- r) ) klers with a glass bulb thermal element. '-- Model F1 FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model El FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Conventional Recessed Pendent/F1/F2 I Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model El FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model Fl FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model El and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model El FR56 Concealed Pendent and Model El FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model Fl FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model Fl FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model E1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model Fl FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model El FR56 Concealed Pendent and Model El FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model El FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model El FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34,5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height g Installation Wrench mm SIN Listings and Approvals Approval Notes US Metric inches mm inches Pendent 2.25 57 W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 W2 RA 1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 W2 RA 1423 cULus 1,2 Pendent 2.25 57 W2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPcB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 GFR2 RA1414 cULus,VdS,EC 5,6 F1FR56 5.6 80 1/2 15 Upright 2.25 57 W2 RA1425 cULus FM, , LPCB, VdS, EC 1,2,3,4 "Conventional 2.25 57 (Pendent or Upright)" W2 RA1475 LPCB, VdS, EC 4 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 1 57 GFR2 RA14151 cULus, ULH F1FR56LL 5.6 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. 2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. iI Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating I 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating I 200°F (93°C) I Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb I Red Bulb I Yellow Bulb I Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- _________ Upright cULus F1FR4O Pendent VdS Recessed Pendent VdS -- Pendent cULus FIFR42 Recessed Pendent cULus I -- _________ Upright cULus F1FR42LL Pendent -- I cULus, ULH I -- I Recessed Pendent -- I cULus, ULH -- Pendent cULus F1FRXLH Recessed Pendent cULus I -- _________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- I FIFRS6 Concealed Pendent* cULus cULus,VdS,EC I cULus -- Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent -- cULus, ULH -- FIFR56LL Recessed Pendent -- I cULus, ULH I -- _________ Concealed Pendent* -- I cULus, ULH I -- Horizontal Sidewall cULus, FM Fl FR56 _________ Recessed Horizontal Sidewall cULus, FM I -- F1FRS6 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model El FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model COP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (570C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector! Model Fl Model F2 Model FP Model Orientation (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS,EC F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 2 7/4" HOLE DIA [5 7.2mm] FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8 "[9.5mm] F2 ESCUTCHEON AT MAX/MUM RECESS = 3/4 "[19mm] /77- / / 77-71 MINIMUM RECESS = 3/8"[9.5mm] I 15/16" 014 [49.2mm] L—__+_---- r ( / I (1 1" X 1/2" REDUCER Fl ESCUTCHEON 8 . AT MAX/MUM RECESS = 7/8"[22,2mm] [3.2-ml I / AT MINIMUM RECESS = 1-5/8"[4 1.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8"[28.6mm] AT MINIMUM RECESS = 1-5/8"[41.3mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS -\ Fl ESCUTCHEONJ_ 3/4'T19mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12.7mm] ADJUSTMENT f 2 27/32" OH. [72.2mm] Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model El or F2 escutcheon cM r 1 X 1/2 REDUCER 2 5/8" 0/A. [66.7mm] " " HOLE IN CEILING I \ / 2 5/76" 0/A. [58.7mm] I / CUP CEILING A FACE OF FITTING I AT MAXIMUM RECESS = 1- l/2"[38mm] I TO FACE OF CEILING DIMENSION AT MINIMUM RECESS = 1 "[25.4mm] Y2'[12.7mm] J I AT MAXIMUM RECESS = 9/16"[14.3mm] AT MINIMUM RECESS = 1 "[25.4mm] ADJUSTMENT ___________ 3 1/4" 0/A. __ [82.6mm] Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, E1ERXLH & F1ER28 Recessed Pendent sprinkler with Model FP escutcheon 5. 1" x 1/2" REDUCING TEE OR ELBOW IT EiitLi - 2 5/16" DIA - CUP CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[l9mm] AT MINIMUM RECESS = 3/8 "[9.5mm] 1-2 1/4" HOLE DIA. I [57.2mm] [3.2mm] Fl ESCUTCHEON AT IAn VII Al III orrrcc - 1 7 /0 "r 7 A t ___1 Ill IVItAIIVflJIVl I1LI...L.).) - I —0/0 1 AT MINIMUM RECESS = 2-1/16 "[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[41.3mm] AT MINIMUM RECESS = 2- 1/16"[52.4mm] I 1" X 1/2" REDUCER r._Jrr I 1115/16 DIA. [49.2mm] , I 44J1 111111 \.t 1 L L TURN COLLAR UNTIL —' TIGHT AGAINST SPRINKLER WRENCH BOSS. 2 27/32" DIA. [72.2mm] Fl ESCUTCHEON [• 3/4"[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12. 7mm] ADJUSTMENT V (1) 4"-12" [10 1.6mm-304.8mm] CEILING TO DEFLECTOR RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 2 5/8" DIA. -H HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 1/2" MAX. -.4 COVER ADJUSTMENT / COVER PLATE ASSEMBLY / 3 5/16" DIA SPRINKLER CONCEALED, 1/2" ADJUSTMENT 017FG01A Fig.4 Model Fl FR56JF1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate [;J 1" x 1/2" REDUCING TEE DR ELBOW ------ - ------ - - 2 5/8" 0/A. 2 5/16" 0/A ..l HOLE IN CEILING CUP - 17/'!'''' L{'." CEILING—" - 5/16" MAX. COVER ADJUSTMEN 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" COVER PLATE — -' ASSEMBLY SPRINKLER ---- CONCEALED, 5/16" ADJUSTMENT 017F502A Fig. 5- Model El FR56/E1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model El FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon I Cover plate11 Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated )4 White Painted I Special Application Finishes Sprinkler Escutcheon Cover plate1 Electroless Nickel PTFE(7) Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint 2116 Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as 'Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, OM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [E1ER28][E1ER40][F1ER42] [El ER42LL][E1 ERXLH][E1 FR56][El ER56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent] [Upright] [Conventional] [Horizontal Sidewall] [Recessed Horizontal Sidewall] [Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/21 Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°E (79°C)][200°E (93°C)][286°E (141°C)] Sprinkler Finish Escutcheon Model: [F1][E2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (570C) for use with Ordinary Temperature sprinklers][ 1 65'F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model Fl FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800)431-1588 Sales Offices Paper Reliable (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/19 P/N 9999970300 AMMYS® FOR WOOD -No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a video demonobabon at www.itwbuildex.com #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part #8114910 1/4' 8002957 GST 100 1/4x 1" 210 (7/16" OSB) 670 (3/4" Ply) 25 125 1 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 3/8" 8007957 GST 10 1/4x V 210 (7/16" OSB) 670 (3/4" Ply) 300 25 125 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8' 8068925 GST 20-SS 114x2" 1760 (Fir) 850 25 125 8009925 GST 25-380 318x2-1/2"2113(Fir)1500 25125 3/8' 8010957 GST 30 1/4x3 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 1/2" 8013925 GST2 1/4x2" 1760 (Fir) 25 125 1/2"8015925GST 31/4 x 3_2275(Fir)25125 1 QDU$AVO SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into h contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams. Not less than 2" nominal width (1-1/7) up to 3-1/2" pipe; not less than 3" (2-1/2') nominal width 4" & 5" pipe 4 1 O_ 1 , 1510. ES MMYS1 No pre-drilling required. Quick to install using the Sammy Floorjo Nut Dver with an 18V cordless i drtlWdver. Saves time from traditional methods. Reduces installation costs. I • Manufactured in the U.S.A. Watch a video demonstration at vw.itwbuildex.com I #14 SW Red Nut Driver Part #8114910 1/4 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8" 8020957 SWG 10 1/4x 1" 622 (Fir) 300 25 125 _J 3/8" 8021957 SWG 20 1/4x2" 1725 (Fir) 1050 25 125 3/8" 8073925 SWG 20-SS 1/4 x 2 1725 (Fir) 850 25 125 1 3/8" 8022925 SWG 25-380 318x2-1/2" 2249 (Fir) 1500 25 125 3/8" 8023925 SWG 30 1/4x3 1884 (Fir) 25 * May require pre-dnlling; consult joist manufacturer. WOWJOW ORKMM MAXAMMW 1•. Eliminates distortion of threaded rod. "Accommodates up to 3 W x 12 pitch roof. "Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. 1#14 Black Nut Driver Párt# 8113910 #14 SH Orange Nut Driver Part #8273910 .OL<5 3/8" 8139957 SH-GST2O 1/4x2" 1257(Fir) 1050 1475 1903 Dim. Lumber 1500 3/8" 8269957 SH-GST/CST 20 5/16x1-3/4" 1406 @ 45"off vertical 850 @ 45" Dim. Lumber 903 Dim. Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 a 1-3/4" 1406 @ 45"off vertical Dim. Lumber May require pre-drilling; consult joist manufacturer. 25 125 25 1251 25 125 MMYS® FOR CONCRETE Easy two step process (Drill hole & drive Sammys concrete anchor). Y."pre-drilled pilot hole required. Concrete Installation Tool available for a one tool installation process. Manufactured in the U.S.A. Approvals Rod Size Part Model Number Screw Descriptij Watch a video demonstration at www.itwbuildex.com #14 Black 1/4" 8058957 CST 200 5/16 x 1-3/4" 2400 25 125 Nut Driver f 3/8 8059957 CST2O 5/16x 1-3/4" 2400 1475 25 125 I Part# 8113910 #143W Red 3/8" 8145925 CST 20-SS 5/16x 1-3/4" 2400 25 125 Nut Driver -t: 1 1/? 8060925 CST 2 5/16 x 1-3/4" 2400 25 125 Part # 81149 10 * Tested in 3000 PSI concrete __________________ Easy two step process (Drill hole & drive Sammys concrete anchor). C; 1h" pre-drilled pilot hole required. c Concrete Installation Tool available for a one tool installation process. V ... -; Manufactured in the U.S.A. . a• Watt), a video demonstration at . www.itwbulldex.com -----SizApprovals Rod Part Number I MOUNT HORIZONTAL MO -[ 1/4' 8062957 3/8 8061957 #143W Red Nut Driver Part #8114910 SWC 200 5/16 x 1-3/4" 2450 25 125 SWC20 5/16x1-3/4 2450 1475 25 12_] * Tested in 3000 PSI concrete Q,op—%%SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation IV each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins ,,W&AC1LtrED U.S.A. free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. APPROVED 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST 20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST 20 SS X 2-1/2 850 1.5 8010957 GST 30 X 4 1500 1.5 X 4 1475 1.5 8009925 GST 25-380 X 4 1500 1.5 8022925 SWG 25-380 X 3-1/2 - 4* 1500 1.5 8021957 SWG 20 X 2-1/2 3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SH GST 2O X 3 1050 1.5 X 4 1475 1.5 8141957 SH GST 3O X 4 1500 1.5 X 4 1475 1.5 I Minimum Minimum I BX PIN STEEL UL UL Max Pipe UL Test Steel FM FM Max FM Test Steel I Size, in Load Pipe Size Load Thickness, in. Thickness, 8038957 DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 BX P/N CONCRETE FM FM Max FM Test Material Pipe Size Load 8059957 CST 20 X 4 1475 3000 PSI 8061957 SWC20 X 4 1475 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" g UL and FM tests were performed in compliance with NFPA-13 Standards. ir myBu"Idex Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pouncs www.itwbuildex.com 800-284-5339 SSS26 0506 Fig. 65 Patent #4,570,885 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1 /16 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 1/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1 /16 11/4 1 7/16 1 610 28 1/2 1 /2 1/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 1I4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2' and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/41 (Fig. 66). Features - All steel construction eliminates structural deficien- cies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4' pipe, 1/2' rod will support 1/2" thru 8" pipe. Finish - Plain Note - Available in Electro-Ga Ivan ized and HDG finish. Order By - Figure number, rod size and finish S CS OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Size Range - Secures 3/8" thru 7/8' rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish --- Plain Note - Available in Electro-Ga Ivan ized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona. CA 92879 • Ph: 951.737.5599 • Fax 951.737.0330 Customer Service • 800.786.5266 www.tolco.com Fig. 200 - "Trim line" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650° F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200 WON. Order By - Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/8 2 /8 400 11 3/4 3/8 8mm or 10mm 31/ 21/2 400 11 1 3/8 8mm or 10mm 33/s 21/8 400 12 1 /4 3/8 8mm or 10mm 33/4 2 /8 400 13 1/2 3/8 8mm or 10mm 3 /8 2/ 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21I2 3/8 10mm 55/8 41/ 600 27 3 3/8 10mm 57/s 4 600 29 31!? 3/8 10mm 73/s 51/4 600 34 4 3/8 10mm 7 /8 5 1000 35 5 1/2 12mm 91/s 61I4 1250 66 6 1/2 12mm 101/ 6I4 1250 73 8 1/2 12mm 131/8 8/4 1250 136 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 CI Customer Service • 800.786.5266 www.tolco.com \ A - A j Dimensions 'Weights Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range - 3/8" and 1/2' rod; 4" thru 16" length.** Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1. Features - Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mecha- nism of some kind, such as the beveled locking slot of the Fig. 69R or a hex nut tightened against other types of retaining straps will provide a more secure and reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, rod or set screw size and length Note - Minimum return on Strap: 1". * Patent #5,947,424 Rod Size A Length 3/8" Specify 1/2" Specify Office/Manufacturing Facility • 1315 Sampson Ave. • Corona, CA 92879 • Ph; 951.737.5599 • Fax; 951.737.0330 I' Customer Service • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer Size Range - One size fits 3/4' thru 2" pipe. Material - Steel Function - Designed to be used in conjunction with TOLCOTM Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed Qn!Y when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 / Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951737.5599 • Fax: 951.737.0330 A Customer Service • 800.786.5266 www.tolco.com All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 102 Fire Protection Solutions B-Line by ET-I'd I T- ( .) Threaded Accessories HN - Standard Hex Nut (TOLCO Fig. 113) Size Range: 1/4"20 thru /8°-9 Material: Steel Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number size and finish aàj Part For Width Across Width Across Approx. Number Rod Size Flats Points Thickness W000 in. (mm) in. (mm) in. (mm) lbs. (kg) HN-1/4 1/4 -20 7A6" (11.1) ½" (12.7) /32 (5.7) 0.7 (0.3) HN-3/a 8-16 ,16 (14.3) 21/32° (16.6) 21/64" (8.3) 1.6 (0.7) HN-1/2 ½-13 3/4" (19.0) /64° (21.8) /16" (11.1) 3.1 (1.7) HN-5/8 5AII-11 15,16° (23.8) 1/32" (27.8) /64° (13.9) 7.3 (3.3) HN-3/4 /4-10 1W (28.6) 1/16" (33.3) '/& (16.3) 12.0 (5.4) 1,16' (33.3) 1/64" (38.5) 3/4 (19.0) 19.0 (8.6) HHN - Heavy Hex Nut (TOLCO Fig. 114) Size Range: 1/4°..20 thru /8 -9 Material: Steel Finish: Plain or Electro-Ga Ivan ized. Contact B-Line for alternative finishes and materials. Order By: Figure number size and finish Part For Width Across Width Across Approx. Number Rod Size Flats Points Thickness W000 in. (mm) in. (mm) in. (mm) lbs. (kg) HHN-1/4 /4-20 ½ (12.7) /64° (14.7) /64' (5.9) 1.2 (0.5) HHN-3/8 j -16 11A6" (17.5) 51/6 " (20.2) 23/64' (9.1) 3.1 (1.4) HHN-1/2 ½-13 7W (22.2) 1'i8 (28.6) 31/64 (12.3) 6.5 (2.9) HHN-5/8 W-ii 1 16 (27.0) 115M (31.3) /64° (15.5) 12.0 (5.4) HHN-3/4 3/4% 10 11/4° (31.7) 129,t4 (36.9) /64' (18.6) 19.0 (8.6) HHN-1/8 1,'_9 17A6 (36.5) 12142 (42.6) /64 (21.8) 30.0 (13.6) (?) Threaded Accessories ", J FW - Flat Washer (TOLCO Fig. 115) Size Range: 1/4"..20 thru 1°-8 rods Material: Steel Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number size and finish Part For Outside Approx. Number Rod Size Diameter Wt/10 in. (mm) lbs. (kg) 1/4 .20 3/4"19.o) - !J.H •i FW-3/8 3,B"-16 1" (25.4) 3.9 (1.7) FW 1/2 - 'W-13 - - 13W (349) 67 (30) ] FW-5/8 5A"- 11 l/4" (44.4) 7.3 (3.3) FW-/4 3/4 10 2 (508) 110(50( 21/4" (57.1) 19.0 (8.6) FN-1 1-8 21h" (69.8) 22.0 (10.0) LW - Lock Washer (TOLCO Fig. 117) Size Range: 1/4"20 thru V-8 rods Material: Steel Finish: Plain or Electro-Galvanized. Note: Available in Hot Dip Galvanized finish or Stainless Steel materials. Order By: Figure number size and finish Part For Outside Approx. Number Rod Size Diameter W000 in. (mm) lbs. (kg) LW-1/4 ¼"-20 .49" (12.4) 0.3 (0.13) LW-3M 3A-16 .68" (17.3) 0.6 (0.27) LW_1/2 ½"-13 .88" (22.3) 1.3 (0.59) LW-5 %"-ii 1.08" (27.4) 2.4 (1.09) LW-3/4 /4"-10 1.27" (32.2) 3.8 (1.72) LW-1/e 1N-9 1.46" (37.1) 5.9 (2.67) LW-1 1°-8 1.66" (42.1) 8.8 (3.99) FFW - Flat Fender Washer (TOLCO Fig. 119) Size Range: /8"-16 and 1/2".13 rods Material: Steel Function: To provide a greater bearing surface than standard washer. Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number and size Part For Inside Outside Approx. Number Rod Size Diameter Diameter WL/100 in. (mm) in. (mm) lbs. (kg) FFW-3/8 3W-16 ½" (12.7) 1'i8" (28.6) 3.0 (1.3) FFW-1k ½'-13 9A6" (14.3) Z' (50.8) 2.8 (1.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 103 B-Line by FT'1J