Loading...
HomeMy WebLinkAbout1940 CAMINO VIDA ROBLE; ; FPC2018-0358; PermitPERMIT REPORT Ccityr of Carlsbad Print Date: 05/11/2022 Permit No: FPC2018-0358 Job Address: 1940 CAMINO VIDA ROBLE, CARLSBAD, CA 92008-6516 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2120921300 Track #: Valuation: $74,416.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Fixed Extinguishing Syste Applied: 10/31/2018 Issued: 11/13/2018 Finaled Close Out: 03/11/2020 Final Inspection: INSPECTOR: Fieri, Dominic Wong, Cindy Maldonado, Adalmira Project Title: Description: CAL-COMP USA -ARGON ITE CLEAN AGENT FIRE SUPRESSION SYSTEM IN PRINTER ROOM Applicant: FPContractor: HCI SYSTEMS INC HCI SYSTEMS INC GARRETT COPE 4585 MURPHY CANYON RD 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 SAN DIEGO, CA 92123-4318 (909) 628-7773 (619) 559-1924 FEE AMOUNT FIRE Reinspection (per inspection) $193.00 FIRE Special Extinguishing System $586.00 Total Fees: $779.00 Total Payments To Date: $779.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov __4!• 1 LJ fi DEVICES 'Kidde Fire Systems A UTC Fire & Security Company Effective: January 2011 K-76-801 This document describes all SLC devices used on the Kidde Intelligent Control Panels. SmartOne Signaling Line Circuit (SLC)-255 devices per circuit (No restrictions on Device Type) H ION PHOTO THERMAL (CPD-7052) (PSD-7152) (THD-7252) — Abort Li LHS AlarmLine® Station Manual DAF Release ORION XT AIR-Intelligence High Sensitivity Air Sampling Smoke Detectiol Detection Remote Display Control Modules (RCDMs),1-15 Remote Releasing Module - HVAC - Shutdowns * - Doors and Dampers - Elevator Recall LED Annunciator Modules (LAMs), Suppressi 1-16 __________* Release -- *Additional SLCs ASM Horns/ Relay Strobes Module Relay Outputs *City lie Connection* Notification Appliance Circuit Intelligent Communication Module (ICM)* * Digital Alarm Communicator Transmitter (DACT)* Network Interface Card (NIC) BACnet/Modbus' Kidde Intelligent * Selected Models Control Panel SmartOne® Intelligent devices and modules provide initiating and control inputs and outputs from a single pair of wires on a Signaling Line Circuit (SLC). All SmartOne devices and modules are designed to provide world-class space/haz- ard detection and suppression outputs when needed. They offer greater capacity, flexibility, and reliability than conven- tional and analog detectors because of a built-in 4K microprocessor that gives them on-board intelligence. In a SmartOne network, intelligence is distributed across the network, not confined to the network control unit. Each SmartOne detector has the ability to analyze data and make decisions based on its programmed need. Kidde Intelligent control units are backward-compatible with the installed base of SmartOne initiating and control devices, preserving your investment in Kidde fire suppression system products that you have acquired over the years. To access the Device Index, click here To access Ordering Information, click here rPC2018-0358 1940 CAMINO VIDA ROBLE CAL-COMP USA - ARGONITE CLEAN AGENT FIRE SUPRESSION SYSTEM IN PRINTER ROOM To DEVICE INDEX To ORDERING INFORMATION I 2120921300 11/1/2018 -Page 1 of 25- FPC20I8-0358 VOW& Fire Systems DEVICES A UTC Fire& Security Company Effective: January 2011 DEVICE INDEX SMARTONE® INTELLIGENT DETECTORS The unique SmartOne® Detectors provide true distributed intelligence by storing and analyzing calibration data and pre-alarm and alarm values. Each detector head continuously makes on-location decisions and reports status to the Control Unit as required. Select the device below to obtain additional product information. Device Description Illustration SmartOne Ionization A low-profile intelligent smoke detector that uses an ionization Smoke Detector, sensing chamber. This detector can be utilized for open-area coy- Model CPD-7052 i erage or can be mounted n a duct with air velocities up to 2,000 feet per minute. SmartOne Photoelectric A low-profile intelligent smoke detector that uses a light-scattering Smoke Detector, sensing chamber. This detector can be utilized for open-area coy- Model PSD-7152 erage or can be mounted n a duct with air velocities up to 4,000 i feet per minute. SmartOne Thermal The Model THD-7252 Thermal Detector is a low-profile, intelligent Detector, heat detector that uses a thermistor sensing chamber for fast Model THD-7252 response. This detector can be used for open-area coverage on low (< 10 ft.), flat ceilings with a spacing up to 70 ft. Flanged Detector Base, The Model 6SB Detector Base is used in applications where the , Model 6SB detectors installed appearance s a primary consideration. This i i base mounts to standard 3-, 3%-, and 4-inch electrical boxes. 1 The Model 4SB Detector Base is used in underfloor applications, Flangeless Detector Base, or in applications where the detector's installed appearance is not V Model 4SB a primary consideration. This base mounts to standard 3- or 3%- V inch electrical boxes. Detector Base Adapter, The Model MA-002 Detector Base Adapter allows the low-profile ... Model MA-002 SmartOne detectors to be retrofitted into the older-style SmartOne detector base, PIN 70-400000-001. The Model DH-2000 Duct Housing is used to enclose an intelligent smoke detector that is monitoring for smoke in an air duct but - Duct Housing, located outside of the duct. The duct housing is used with inlet and Model DH-2000 outlet tubes that allow the air in the duct to be sampled uniformly - and transported to the enclosed smoke detector for obscuration- level measurement. SMARTONE® INTELLIGENT MODULES The SmartOne® Addressable Modules are intelligent field devices with their own microprocessor, memory and elec- tronics necessary to interface input and output devices to the intelligent control unit. Select the SmartOne module on the next page to obtain additional product information. - Page 2of25- Device Description Illustration The Model Al Addressable Monitor Module is used to monitor conven- SmartOne Addressable tional, unpowered, contact-type initiating devices through a Class-B, Monitor Module, Style-B initiating device circuit. The Al Modules are designed to be Model Al mounted in the electrical box-of the device being monitored. The Model AAM Addressable AlarmLine Module is a monitor module that enables an AlarmLine sensor cable to report pre- SmartOne Addressable alarm and alarm or overheat events, and trouble signals to the AlarmLine Module, control panel through the signaling line circuit. The MM, P/N 73- Model AAM 100001-003, is equipped with a metal cover plate for mounting to a 4" square electrical box. P/N 73-100003-001, is a surface- mount, NEMA-4 enclosure for the MM. The Model AO Addressable Relay Module provides an unpow- SmartOne Addressable ered Form-C contact for remote control applications. The AO Relay Module Module s designed to be mounted in the electrical box of the i ____________________ Model AO device being controlled. The Addressable Signal Module permits notification appliances to be controlled by commands issued via the SLC. The ASM is sup- SmartOne Addressable plied with a thermoplastic mounting cover and is designed to Signal Module, mount in a standard 4-11/16" electrical box or a 4" square, extra- Model ASM deep electrical box. The PALM is a monitor module that enables the ORION XT High PEGAsys Addressable Sensitivity Smoke Detector (HSSD) to report Pre-alarm, Alarm, Loop Module (PALM) for and Trouble signals to the control unit via its signaling line (SLC) ORION XT Detectors circuit. The AIM mounts inside the AnaLASER II detector housing. Ell AIR-Intelligence Smart- The AIR-Intelligence SmartOne APIC is an interface module One Addressable which integrates AIR-Intelligence High Sensitivity Smoke Detec- Programmable Interface tors with the control unit via its signaling line circuit (SLC). The Card (APIC) APIC mounts inside the AIR-Intelligence detector housing. Isolator modules are automatic switches that open a segment of the signaling line circuit when a short-circuit fault is detected in Isolator Modules that segment. The remainder of the signaling line circuit continues -.., •. i to function normally and s unaffected by the short-circuit fault. The isolator modules will close and resume normal operation FEWML when the short-circuit fault is removed. The Remote Releasing Module (RRM) provides the ability to SmartOne Remote remotely activate extinguishing-system control devices (for exam- Releasing Module pIe, electro-explosive initiators and solenoid valves). Connection is via the control units signaling line circuit (SLC). Addressable Manual Pull The Addressable Manual Pull Station contains its own SmartOne Addressaable Input (Al) module and interfaces directly to the Station SmartOne compatible control panels. I C Series 3300 * - Page 3 of 25- Back to Index Distributed Intelligence Photoelectric & Ionization Smoke and Thermal Detectors The Intelligent Smoke Detectors Ordering Info Effective: January 2011 0=:3 FEATURES True Distributed Intelligence Field Programmable Alarm and Pre-Alarm Set Points Internal Supervision Calibrated Alarm Test by Command to Sensor Level Drift Compensation Non-Polarized Full Analog Display of Detector Values Electronic Addressing UL Listed #51064 FM Approved CSFM Approved: 7272-1076:142 DESCRIPTION These unique SmartOne® Detectors provide true distrib- uted intelligence by storing and analyzing calibration data and pre-alarm and alarm values. Each detector head continuously makes on-location decisions and reports status to the Central Control Panel as required. This distributed intelligence architecture, featuring an intrinsic microprocessor in each individual detector, ana- lyzes data and makes decisions within the monitored area. SMARTONE IONIZATION SMOKE DETECTOR CPD-7052 models are dual chamber ionization type detectors which sense both visible and invisible smoke. A unique sensing chamber design permits full 360 degree smoke entry and response. SMARTONE PHOTOELECTRIC SMOKE DETECTOR PSD-7152 models are smart photoelectric smoke detec- tors. These detectors will respond to a broad range of flaming and smoldering fire conditions. The photoelectric smoke detector can be used for open- area application as well as duct mounting applications with air velocity of 2000ft/min up to 4000ft/min.. SMARTONE THERMAL HEAT DETECTOR Model THD-7252 are thermistor based analog devices that can be programmed to respond to fixed temperature without problems associated with thermal lag. The SmartOne thermal detector can be used for open area applications applications as well as in-cabinet appli- cations. TWO PROGRAMMABLE ALARM SET POINTS The detector alarm, and pre-alarm set point levels are fac- tory-set in units of percent obscuration/foot or degrees Fahrenheit and may be changed by the operator. Both set points, however, can be set within the UL allowable limits which are stored in the nonvolatile memory of the control panel. The pre-alarm set point typically is used as an early warning signal. On receipt of a pre-alarm signal, a trouble condition is generated at the panel. In addition to a physical investigation, the operator may request actual percent obscuration levels from the detector in alarm or any other detector. The alarm and pre-alarm setting of each detector may be changed either electronically from the control unit pro- gram. For example, a detector located in a cafeteria can be programmed to desensitize automatically every lunch hour except weekends and holidays. DRIFT COMPENSATION Each smoke detector is self-monitoring for drift from alarm set point caused by long-term environmental con- ditions, contamination or electronic component aging. Using a carefully designed algorithm, the detector mea- sures and averages 32 days of "normal" smoke level. This data then is used in the drift compensation algorithm to maintain the proper set point as programmed for the unit. If the detector cannot compensate, a trouble signal is sent to the control unit identifying the affected detector and the state "Drift Error." INTERNAL SUPERVISION The SmartOne constantly monitors its own status by supervising and reporting a trouble condition when a fault occurs in one of the following items: Internal Power Supply Voltage Improper Line Voltage from the Control Panel Faulty Data being Written to Memory Uncompensated Drift - Page 4 of 25- Back to Index STATUS LED An LED is provided on the detector to indicate status of the smoke detector. A high flash rate indicates alarm, a slow rate normal. When a trouble exists, the LED is turned off. PROGRAMMING INFORMATION Each detector is field programmed with the owner loca- tion message (location of the detector in the building or on the site), the system address (a four digit code), pre- alarm set point and alarm set point (if different from fac- tory settings). In addition, the detector type, photoelectric, ionization or thermal and the proper calibration are stored in memory at the factory. This permits the Control Panel to verify that the proper detector type using the correct address is installed in the system. The system will reject attempts to program alarm and pre-alarm set point levels exceeding the UL designated window. ALARM TEST BY COMMAND Any or all detectors can be tested by command from the Control Panel. This test procedure precisely duplicates in-place testing of each detector by imposing a signal on the detector sensing chamber that will cause an alarm output. Results of the test will be indicated at the Control Panel or any remote location for monitoring or trouble- shooting purposes. COMMUNICATION VERIFICATION When a detector reaches its pre-alarm or alarm set point, it conducts a verification procedure with the Control Panel which repeats the communication cycle four sepa- rate times before the system accepts its change of sta- tus. The maximum time for this verification procedure is 2.5 seconds. INSTALLATION Detector bases are mounted directly to a 4-in, octagonal box. The detector base is equipped with an integrally molded locking tab to prevent unauthorized removal. Once locked into place, the detector can be removed only by inserting a screwdriver blade into the slot while turning the detector head counterclockwise. RADIOACTIVE MATERIAL Do not attempt disassembly of the fac- A tory sealed sensing chamber. This assembly is sealed for your protection WARNING and is not intended to be opened for servicing. Less than 1.0 microcuries Americium 241 in ionization detector. Shielded by stainless steel housing. Ordering Info APPLICATION DATA Each SLC circuit can communicate with up to 255 addressable devices. The circuitry may be either Class "A" or Class "B". Class "A" requires a series loop circuitry with the loop returning to the SLC connector within the control unit. Class "B" does not require a return to the SLC connector and permits 1-tapping. All SmartOne detectors utilize the same base and may be interchanged. Installation is both simple and fast using screw-type connections and the non-polarized detector feature. The detector is fitted to the base by a twist-to- lock action. A removable locking tab secures the detector to the base to provide some degree of vandal resistance or inadvertent removal. Note: While units are interchangeable, changing detec- tor type will require a change in system program- ming. The ionization smoke detector can be used for open-area application as well as duct mounting applications with air velocity of 2000ft/min up to 4000ft/min. SMARTONE DETECTOR MOUNTING BASES All models of SmartOne detection devices use a univer- sal mounting base arrangement. The mounting base is available in two models, Model 6SB and Model 45B. Base model 65B provides a trim ring which masks any inconsistencies between the electrical box and the ceiling material. Model 4SB is electrically the same as model 6SB but does not provide the trim ring. The 4SB outside diameter matches that of the detection devices thus allowing installation into tight spaces (i.e., underfloor areas). MA-002 MECHANICAL RETROFIT ADAPTOR APPLICATION The MA-002 mechanical retrofit adaptor is used to allow all old style detector bases (Series 70-400000-000) to accept the CPD-7052, PSD-7152 and THD-7252 addressable detectors. No rewiring is required to retrofit the base. The MA-002 is intended primarily for applica- tions such as college dormitories, hotels, and motels where each sleeping room requires a dedicated notifica- tion appliance. It is designed to simplify the design and installation of systems that require selective or sympa- thetic occupant notification with old style detector base. These systems are not only required to notify the occu- pants in the room of fire origin, but also in either the adja- cent rooms or the entire floor of fire origin. -Page 50f25- Back to In SPECIFICATIONS Input Voltage: 16.5-27.5Vdc Standby Current: 350pA, typical Alarm Current: 425pA, typical Max. Detectors per SLC: 255 All detectors can be in alarm simultaneously. LED PULSE MODES Normal: 9 second interval Trouble: LED isoff Alarm: 2 second interval Operating Temperature: 32°F (0°C) - 100°F (38°C) EMI Immunity: Meets UL 268 Note: Nominal factory settings of detectors are as fol- lows: Photoelectric detectors: Alarm 2.0%/ft. Pre-alarm 1.5%/ft. Ionization detectors: Alarm 1.0%/ft. Pre-alarm 0.8%/ft. Thermal detectors: Alarm 140°F (60°C) Pre-alarm 120°F (49°C) SENSITIVITY Open Area: - Ionization: 0.5 - 1.5%/ft. - Photoelectric: 0.5 - 3.5%/ft. High Velocity: - Ionization: 0.5 - 1.0 %Ift. - Photoelectric: 0.5 - 2.0%/ft. THERMAL DETECTOR SPACING 50 ft.: 135°F (57°C) - 145°F (63°C) 70 ft.: 135°F (57°C) - 155°F (68°C) Thermal detectors are limited to 20 ft. spacing when used on FM approved applications. Note: These detectors are compatible only with fire alarm systems utilizing an compatible SLC protocol. -Page 60f25- Ordering Info PSD-7152 CPD-7052 THD-7252 RETROFIT ________ ADAPTER = / MA-002 PIN 70400001-200 I I EXISTING FENWAL 70 400001-000 BASE Back to Index Ordering info Intelligent Air Duct Effective: January 2011 Smoke Detector FEATURES Accommodates Photoelectric and Ionization SmartOne Detectors Easily mounts to round or rectangular ducts 8 inches to 12 feet wide Air Velocity rating 500 to 4000 FPM Clear Lexan cover for easy viewing of smoke detector status and cleanliness UL Listed #S1064 FM Approved #0132A6AV ULC #CS194-E CSFM #3240-1076:121 DESCRIPTION The SmartOne® Model DH-2000 Air Duct smoke detector is designed for detecting particles of combustion in air handling systems. Upon smoke detection the integral detection device will signal the SmartOne compatible control unit to which it is connected. The duct detector housing accepts the SmartOne Intelli- gent CPD-7052 ionization and PSD-7152 photoelectric detectors. A transparent Lexan cover over the detection chamber allows visual inspection of the duct detectors chamber and internal detector status. Sampling air in HVAC ducts is accomplished with the use of sampling tubes which extend into the HVAC duct. AIR HANDLING SYSTEM CHARACTERISTICS The DH-2000 duct detector is suited for use in commer- cial, industrial, institutional and residential fire alarm applications. The DH-2000 will accommodate all ducts with air veloci- ties between 500 to 4000 feet per minute. Both the pho- toelectric (PSD-7152) and the ionization (CPD-7052) smoke detector along with the duct housing will operate over this entire range. The duct detector is easily mounted to both rectangular and round ducts from 8 inches to 12 feet wide. When used with the DH-2000 unit, both A the photoelectric (PSD-7152) and ion- ization (CPD-7052) detectors must be WARNING configured for Duct application when programmed in the control unit. SAMPLING TUBES The DH-2000 duct detector operation is based upon an air sampling principle. Two sampling tubes extend into the HVAC duct to transport air from the inside of the duct into the duct detectors sensing chamber and exhaust it back out into the duct. If the sampled air contains a con- centration of smoke greater than or equal to the alarm threshold of the internal smoke detector, the unit will go into alarm. The duct detector's inlet supply sampling tube is selected according to the size of the HVAC duct. The unit's exhaust tube is molded into the housing to simplify instal- lation. ENCLOSURE INLET TUBE (SUPPLY) DETECTOR VIEW PORT - Page 7 of 25 - Back to Inde I Ordering Info Addressable Contact Input Device Effective: January 2011 a=:3 FEATURES Monitors N.O. or N.C/ Unpowered Contacts Full Digital Communications Class B Initiating Device Circuit Remote-led Output Alarm Test from Control Unit Keypad UL Listed #S3743 FM Approved #ODA9AY CSFM #7300-1076:144 DESCRIPTION The SmartOne® Addressable Contact Input Device (Al) is an intelligent field device with its own microprocessor, memory and electronics necessary to interface N.O. or N.C. unpowered contacts to the FenwalNET control units. All of the electronics are contained in a high-impact polymer case, creating a very small and durable device for installation. Two types of Al's are available: an Al/NC for interfacing to normally-closed devices and an Al/NO for interfacing to normally-open devices. The Al may be located up to 2,500 feet from the monitored device with #18 AWG wir- ing. An end-of-line-resistor is required for supervision of the wiring to the device. FIELD PROGRAMMING System address, owner location message and reporting type are programmable via the compatible control unit configuration software program. The System address is a 4-digit number that uniquely identifies each device. The owner location message is a 40-character, alpha numeric message that describes the location of the device. The reporting type is assigned to the Al depending on the functionality of the device being monitored. SUPERVISION The Al continuously monitors the integrity of the follow- ing: Continuity of supervised wiring Power/Communications circuit voltage Internal power supply Memory data Faulty entering of data into Al memory STATUS LED A remote status LED may be connected to the Al. ALARM TEST Any or all Als can be tested by command from the com- patible control unit. Results of the test may be printed out at the system printer. SPECIFICATIONS Input Voltage: 16.5-27.5VDC Standby Current: 450 mA Max Alarm Current: 450 mA Max Operating Temperature: -31 - 151°F (-35 -66°C) 0 - 95% RH LED PULSE MODES Normal: 9 second interval Trouble: LED isoff Alarm: 2 second interval Acceptable Wire Size: 14,16,18AWG Installation: The Al can be mounted in a North American 2-1/2-in. (64 mm) deep, 1-gang box, or standard 4-in, square box,1-1/2-in. (38 mm) deep with cover. - Page 8 of 25 - Back to Index I Ordering Info I AlarmLine TM Addressable Effective: January 2011 Linear Heat Detector PIN 73-100001-003 FEATURES Low-cost interface between AlarmLine TM sensor cable and control panel accepting SmartOneTm addressable devices Real-time monitoring Software adjustable alarm set point Optional pre-alarm and overheat output configuration selections Three cable styles (standard, nylon, bronze braided) Sensor cable restorable up to 2570F Full supervision for short and open circuits Two-color status-LED display for alarm and trouble conditions Intrinsically safe option Flexibility in zoning Enhanced response time UL Listed #S492 FM Approved #3005511 CSFM Approved #7270-0074:110 DESCRIPTION The AlarmLine Addressable Linear Heat Detector provides early detection of fire or overheat condition in protected areas or equipment. It is especially suited for confined areas or environments where adverse ambient conditions cause other detection devices to be unreliable or difficult to use. The detector consists of two major components: A sensor cable and an Addressable AlarmLine Module (MM). The AlarmLine can be programmed to send pre-alarm, alarm, and overheat levels for differing ambient conditions as well as sending fault signaling of open and short circuit, and overheat conditions. The cables are self restoring up to 257°F (125°C). The MM is compatible with the PEGAsys, ARIES, and ARIES NETLink panels. APPLICATIONS Open-area protection Cable trays Rack storage Freezer warehouses Belt conveyers Floating roof fuel tanks Cooling towers Dust collectors Waste fuel drum storage Power distribution apparatus Escalators Tunnels Mines Hangars ANALOG HEAT SENSING AlarmLine's analog heat sensing characteristics offer several distinct advantages: Field Adjustable pre-alarm, alarm, and overheat set points: Pre-alarm, alarm, and overheat thresholds may be programmed to meet specific system requirements. Integrating: It is not necessary to reduce sensor spacing with increased ceiling height per NFPA 72-2010 Section 17.6.3.5.1, Exception (1). System sensitivity remains constant as ceiling height increases without reducing spacing. Short Circuit Discrimination: The system will produce a trouble condition instead of a false alarm in the event of a conductor to conductor short due to damage or electrical faults. - Page 9 of 25- Back to In SENSOR CABLE The AlarmLine sensor cable consists of four 26 AWG copper conductors, each color-coded in an insulated sheath containing a negative temperature coefficient polymer (where an increase in temperature decreases the resistance of the sensor). Two of the conductors are enameled and provide loop continuity supervision, but not temperature sensing. The conductors are twisted at thirty turns per foot (90 turns per meter) and protected by a flame-retardant outer extrusion or metallic braid (See Figure 1). The color coding of the four inner conductors is repetitively marked on the outer coating every three feet as an aid installation. The maximum length of sensor cable per zone depends on the maximum ambient temperature defined on the nomogram(s) (See SmartOne AlarmLine Addressable Linear Heat Detector manual, P/N 06-235820-003). Regardless of ambient temperature, however, the maximum length of cable is 3280 feet (1000 meters) per zone for Type "T" cable. NEGATIVE TEMPERATURE COEFFICIENT MATERIAL SENSOR CONDUCTOR WIRE CABLE SENSOR PROTECTIVE INSULATION HIGH TEMPERATURE PVC Figure 1. Standard Sensor Cable Sensor cable types: Standard Sensor Cable Recommended for environments ranging from clean and dry to moderate dust and moisture. Nylon Coated Sensor Cable Recommended for use in wet, oily, or corrosive environments or outdoors. Use in freezer warehouses. Phosphor Bronze Braided Sensor Recommended for applications requiring superior abrasion protection and/or increased tensile strength. ADDRESSABLE ALARMLINE MODULE (AAM) The AAM permits an AlarmLine sensor cable to be directly interlaced to a SmartOne compatible control unit. This interface will allow for pre-alarm, alarm, and trouble conditions to be transmitted to the control panel via the Signaling Line Circuit (SLC). The AAM monitors the resistance of the sensor cable and generates a pre-alarm (if enabled), alarm, or overheat output (if enabled) when the resistance drops below the programmed threshold. The module also supervises the AlarmLine cable for opens and shorts, which will generate a fault condition. Ordering Info All of the pre-alarm, alarm, overheat, and trouble conditions will be displayed on the control panel. Up to 255 MM modules can be connected to a single SLC loop. Use of multiple AAMs allows flexibility in zoning larger installations for location of alarm and zone output control; the control panel acts as a central display and control interlace. The MM receives power directly from the SLC loop which eliminates the need for additional wiring and external power supplies. CABLE SPECIFICATIONS Bronze Standard Nylon Coated Description Braided Sensor Sensor Sensor Part Number: 73-117068-013 73-117068-016 73-117068-019 Length: 656 ft. (200 m) 656 ft. (200 m) 656 ft. (200 m) Weight: 7 lbs. (3.2 kg) 7 lbs. (3.2 kg) 7 lbs. (3.2 kg) Part Number: 73-117068-113 73-117068-116 73-117068-119 Length: 3280 ft. (1000 m) 3280 ft. (1000 m) 3280 ft. (1000 m) Weight: 35 lbs. (14.5 kg) 35 lbs. (14.5 kg) 35 lbs. (14.5 kg) Jacket Blue PVC Black nylon Phosphor Construction extrusion over bronze braid blue PVC over blue PVC External 0.117 in. 0.153 in. 0.153 in. Diameter (3 mm) (3.9 mm) (3.9 mm) Tensile 100 100 1000N Strength Conductor 1 = Orange 1 = Orange 1 = Orange Insulation 2 = White 2 = White 2 = White Costs 3 = Red 3 = Red 3 = Red 4=Blue 4=Blue 4=Blue Conductor 26 AWG Solid 26 AWG Solid 26 AWG Solid Material Copper Copper Copper Conductor 0.018 in. 0.018 in. 0.018 in. Diameter (0.460 mm) (0.460 mm) (0.460 mm) Twist of Inner 30 per ft. 30 per ft. 30 per ft. Conductors (90 per m) (90 per m) (90 per m) Dielectric Specially Doped Specially Doped Specially Doped Material Polymer Polymer Polymer Standard Outer High High High Jacket Material Temperature Temperature Temperature PVC PVC PVC Voltage Proof 10 K 10KV 10 K Between PVC Jacket and a Conductor Service Life Up to 212°F Up to 212°F Up to 212°F (100°C)=30 (100°C)=30 (100°C)=30 years © 257°F years @ 257°F years © 257°F (125°C)=24 (125°C)=24 (125°C)=24 hours, hours. hours. Self Restores Self Restores Self Restores below 257°F below 257°F below 257°F (125°C) (125°C) (125°C) Above 374°F Above 374°F Above 374°F (190°C) is the (190°C) is the (190°C) is the destructive destructive destructive temperature. temperature. temperature. - Page 10 of 25- Back to Index Standard Nylon Coated Bronze Description Sensor Sensor Braided Sensor Approved 30 ft. 30 ft. 30 ft. Spacing (9 m) (9 m) (9 m) (between parallel runs) SENSOR MOUNTING HARDWARE Three types of standard mounting hardware (master clamp, flange clamp, nylon cable tie) for AlarmLine permit safe, secure sensor cable installation in most applications. Other mounting means may be used as required by the specific application. The sensor should be supported at a minimum of ten foot intervals on straight runs when under tension, and more as conditions dictate at corners and transition points to provide suitable strain relief. Local codes or conditions may also require the sensor to be supported at closer intervals. Refer to the AlarmLine Addressable Linear Heat Detector Installation, Operation, and Maintenance Manual, P/N 06-235820-003 for specific mounting information. AAM SPECIFICATIONS Specification Value Part Number 73-100001-003 Supply Voltage P.C. Line, 16.5 to 27.5 Vdc Current consumption, Standby 425 pAmps Current consumption, Alarm 440 pAmps Current Consumption, Fault 425 pAmps Noise Performance Withstands 5% RMS 60 Hz supply noise or I Vrms 60 Hz sensor noise with negligible performance range. RFI immunity at 10 V/meter field strength over the band of 20 to 900 MHz Normal: Slow flash GREEN every nine (9) seconds Pre-Alarm: Slow flash RED LED Pulse Modes every nine (9) seconds Alarm: Fast flash RED every two (2) seconds Trouble: Off Operating Temperature Range -40°F to 140°F (-40°C to 60°C) Ordering intol INTRINSIC SAFETY BARRIERS In classified hazardous areas where potentially explosive vapors, dust, or fibers exist, AlarmLine cable must be installed using an intrinsic safety barrier. The barrier (PIN 73-117068-031) is a shunt diode safety barrier which limits the current and voltage in the sensor cable to safe levels. Each barrier handles two conductors, so two barriers are needed for each sensor cable. The barriers are designed to mount in separate weather tight enclosures. The intrinsic safety barrier's specifications are as follows: UL Listed and FM Class I, Division I, Groups A, B, C, D Approvals Class II, Division I, Groups E, F, G: Class Ill, Division I Operating Tempera- -4°F (-20°C) to 140°F (60°C) ture Range Humidity 5-95% R.H. Terminals Will accept up to #12 AWG Working Voltage 6V Maximum Voltage 7.5V Fuse Rating 100 mA Leakage Current I mA maximum at 6V End-To-End Resis- 145 ohm maximum tance 90 ohm minimum Enclosures 73-117068-732 holds 2 barriers 73-117068-733 holds 5 barriers 73-117068-734 holds 12 barriers 73-117068-735 holds 24 barriers -Page 11 of 25 - Back to Index Ordering Info Addressable Relay Output Device Effective: January 2011 FEATURES Full-Digital Communications Addressable Control Point Unpowered, SPDT Relay Contacts Control-by-Event And/or By Time Operation Status Indicator Unique Internal Supervision UL Listed FM Approved CSFM Approved DESCRIPTION The SmartOne® Addressable Relay Output Device (AO) is an addressable output module for control of auxiliary equipment such as air handlers, door release and eleva- tor recall. The AO connects directly to a compatible control unit's signaling line circuit (SLC) and contains a SPDT relay to control auxiliary equipment. All of the electronics are con- tained in a small high-impact polymer case. This creates a small and durable device for installation. FIELD PROGRAMMING The AO is field programmable with a unique four-digit address and a 40-character owner location message. The AO relay may be set or reset on command from the control unit. In addition to combinational-logic programming that uti- lizes system inputs (i.e., events) to activate this device, the unit may be programmed for real-time clock opera- tion. The real-time clock programming permits the AO to be activated and deactivated by the time of day, calendar date and day of the week. SUPERVISION The AO is continuously monitored for: Internal power supply voltages Faulty entering of data into AO's memory Relay state equals command state An internal set of relay contacts provides a feedback sig- nal that confirms the activation of the addressable relay output. If the relay fails to operate at the appropriate time, the device transmits a trouble report for display by the control unit. STATUS LED A status LED is mounted on the unit. SPECIFICATIONS Input Voltage: 16.5 - 27.5 VDC Standby Current: 400 pA, Typical Alarm Current: 400 pA, Typical Contact Ratings: Resistive Contact Rating: - 2A@3OVDC Inductive Rating (Motor Control): - 1.OA @ 30 VDC, 0.6 PF.6A @ 120 VAC, 0.35 PF Pilot Duty - 0.6A @ 30 VDC, 0.35 PF Operating Environment: -31°F - 151°F (-35°C - 66°C) at 0-95% RH EMI Immunity: Meets UL 864 Dimensions: 2.3" x 1.8" x 0.8" nominal Shipping Weight: 5.1oz(145g) LED Pulse Modes: Normal: - 9 second interval Trouble: - LED isoff Alarm: - 2 second interval Acceptable Wire Size: 14,16,I8AWG Installation: The AO can be mounted in a North American 1-1/2-in. (64 mm) deep 1-gang box, or standard 4-in, square box 1-1/2-in. (38 mm) deep with a cover. - Page 12 of 25- Back to Index I Ordering Info ADDRESSABLE SIGNAL MODULE Effective: January 2011 FEATURES Full-digital communications Addressable notification-appliance circuit (NAC) Class Aor Class B wiring on NAC Field-programmable for 24-VDC notification appliances or 25 Vrms speakers Supervises power for notification appliances UL Listed FM Approved #3005511 CSFM Approved DESCRIPTION The SmartOne® Addressable Signal Module (ASM) is a notification-appliance circuit that connects to the signal- ing line circuit of a compatible control unit. The ASM is an intelligent field device that contains its own microproces- sor, memory and the necessary electronics to provide either 24 VDC for conventional notification-appliances or 25 Vrms for speakers. Operation can be changed on-site using on-board switches and jumpers. PROGRAMMING Each ASM can be configured to support speakers or audible-visual notification appliances, and Class B or Class A operation. The module can also be programmed to support water flow, walk test, and drill modes. As with any SmartOne device, addressing can be implemented from the hand-held programmer (P/N 74-227) or the con- trol panel keypad/menu. The Module can also be alarm tested upon command from the control unit. Module faults are individually reported to compatible control units by module address, fault type, and fault-location mes- sage. SUPERVISION The module provides continuous internal supervision of: Alarm contact position Communications with the control unit Internal power supply Connections to external power supply for notification- appliances Memory status module supervision prevents switching audible or audio power into a shorted circuit. STATUS LED A status LED is mounted on the unit. SPECIFICATIONS OUTPUT CIRCUIT CHARACTERISTICS Output Current Rating: 2.0 A max. @ 30 VDC 20W@70.7Vrms 20W@25.0Vrms MAXIMUM LINE RESISTANCES (#12 AWG WIRE) Load (amps) Resistance (ohms) Length (ft.) 0.2 20.0 12.0K 0.5 8.0 5.0K 1.0 4.0 2.5K 1.5 2.7 1.61K 2.0 2.0 1.21K Mounting A 4-inch, 2-1/8-inch deep (for #18 AWG) or 4-11/16- inch, 2-1/8-inch deep (for #12 AWG) standard, square electrical box is used. Wiring specifications are recommended as minimums for ease of wiring. See National Electrical Code (370). Shipping Weight 10.5oz(298g) Current Draw 500 uA in standby or alarm Operating Voltage Range 16.5 to 27.5 VDC 24 VDC nominal Notification-Appliance Circuit End Of Line Resistor 4.7K ohms, 0.5 W - Page 13 of 25 - Back to Indexj Ordering Info Notification-Appliance Circuit Output 24 VDC, 2 A (max.), power limited, reverse polarity supervised Audio Circuit Output 25 V, 20 W (max.), non-power limited, reverse polarity supervised Power Supply Trouble Circuit End Of Line Resistor 4.7Kohms, 0.5 W Operating Temperature Range -31° Fto 151° F, 050 Cto660C) Operating Humidity Range 0 to 95%, non-condensing Installation: The unit can be mounted in a 4-inch x 4-inch electri- cal box. Refer to installation instructions (P/N 06-235717-001) for additional information. - Page 14 of 25- Back to Index Ordering Info P EGAsysTM Addressable Effective: January 2011 Loop Module (PALM) For ORION XT Detectors FEATURES UL Listed FM Approved CSFM Listed NYC MEA Approved MEA Allows HSSD® to be Connected to an ARIESTM or PEGAsysTM Panel as a SmartOnes Detector Up to 255 PALMs Per Addressable Signaling Line Circuit Reports Pre-Alarm, Alarm and Trouble to an ARIES or PEGAsys Panel Real Time Monitoring of Smoke Levels From an ARIES or PEGAsys Panel Mounted Within ORION XT Detector DESCRIPTION The PEGAsys Addressable Loop Module (PALM) is an intelligent loop device that allows an ORION XI High Sensitivity Smoke Detector to be directly connected to an ARIES or PEGAsys Addressable Signaling Line Circuit. The PALM provides increased flexibility in installing high- sensitivity smoke detection, by providing data from the Detector back to the ARIES or PEGAsys fire alarm con- trol panel. The PEGAsysTM Addressable Loop Module (PALM) sits on the ARIES or PEGAsys Addressable Signaling Line Circuit, among other SmartOne sensors or modules. Up to 255 addressable devices of any combination, including the PALM, may be connected to the Signaling Line Cir- cuit. One PALM is required for each ORION XT Detector that is to be connected to the ARIES or PEGAsys Signal- ing Line Circuit. The PALM transmits pre-alarm, alarm and up to six trou- ble messages to the ARIES or PEGAsys panel. The PALM is fully supervised and continuously monitors all aspects of the PALM and ORION XT Detector. Using the menu functions of the ARIES or PEGAsys panel, real- time smoke and airflow levels can be transmitted from the PALM and displayed on the panel. In addition, detec- tor sensitivity tests can be performed from commands on the panel. The PALM is a single circuit board that plugs into a socket on the termination board inside an ORION XI Detector. The easy-to-install PALM "snaps" effortlessly into its mounting hardware and requires no extra hard- ware to install. After mounting the PALM, only five field wiring connections are needed for the Addressable Sig- naling Line Circuit and ground. Power is provided to the PALM via the termination board. The installation of one Kidde Fire Systems IR 01721 PEGAsys" ADDRESSABLE LOOP MODULE CND PART. NO. 297103 OUT ALL TERMINALS ARE POWER UHIIED RXTx IN < ADDRESS - APPROVED Ir] PALM can be completed within minutes. Programming of the PALM (including defining the ARIES or PEGAsys loop address) and history downloading are done with a computer, running ORION Configuration Software that is connected directly to the RS-232 port of the Detector. CONTROL PANEL INTERFACE The PALM communicates the following detector status information and commands to and from the ARIES or PEGAsys Control Panel: Alarm and Pre-Alarm Conditions: Communicated to the ARIES or PEGAsys panel when the ORION XT Detector detects smoke above the programmed alarm or pre- alarm thresholds. Real-time Smoke and Airflow Levels: These levels are accessible through the panel system menus. Trouble Conditions: Communicated to the ARIES or PEGAsys when the ORION XT Detector detects a trou- ble. The Detector monitors the detector head, airflow, power supply, detector isolation and address loop conti- nuity for trouble conditions. Detector Test: Allows the detector sensitivity test to be performed from the ARIES or PEGAsys panel. -Page 15of25- Back to Index Ordering Info TECHNICAL SPECIFICATIONS Input Voltage: 5 Vdc (supplied by termination board) Maximum Input 125 mA at 5 Vdc (supplied Current: by termination board) Adds 20 mA at 24 Vdc to Detector current Operating 320 to 120°F (00 to 49°C) PALM BLOCK DIAGRAM PIPING NE1WORI< DETECTOR I DETECTOR TERMINATION I HEAD L_.OARD IRS-2321 PORT PALM FAN UP TO 255 LOOP DEVICES Temperature: Operating Humidity: Electrical Connections: Shipping Weight: Dimensions: 10 to 93% RH, non-condensing 18 to 12 AWG (0.75 to 2.5 mm2) wiring to removable terminal block 0.3 lb. (0.2 kg) 3-15/16 in. W x 2-11/64 in. H x 1-9/16 in. D(100mmWx55 mm H x 40 mm 0) PIPING NETWORK DETECTOR DETECTOR I TERMINATION IHEADI BOARD PORT PALM FAN ARIES SLC OR PEGASYS - RXITX MODULE LOCAL COMPUTER WITH ORION'° CONFIGURATION SOFTWARE Note: When using a PALM with a PEGAsys panel, ensure that the firmware is 80.0 or later and that the PCS software is Version 8.0 or higher. - Page 16 of 25 - Back to In Ordering Info AIR-IntelligenceTTM SmartON E® Effective: January 2011 Addressable Protocol Interface Card (APIC) FEATURES 2 Distinct Modes of Operation: Single Address Mode Multi-Address Mode Seamless Integration with FN2000, FN6000 and FN 8000-ML Fire Alarm Control Panels Easy to Install Up to 255 APIC Per Signaling Line Circuit (SLC) UL Listed ULC Listed DESCRIPTION The AIR-lnteIIigence SmartONE® APIC is an interface module designed to provide seamless integration between AIR-Intelligence detectors and fire alarm/sup- pression control panels using the SmartOne Signaling Line Circuit (SLC) protocol. The SmartONE APIC card reports the Aspirating Smoke Detector as an "AIM." The SmartONE APIC has two distinct modes of opera- tion: Single Address mode Multi-Address mode In single address mode, the SmartONE APIC is con- nected directly to a detector main circuit board, using a ribbon cable. In multi-address mode, the SmartONE APIC is connected to a command module using a ribbon cable. The com- mand module is connected to a SenseNET loop contain- ing multiple detectors, and the SmartONE APIC acts as the interface between all these detectors and the control panel. The SmartONE APIC senses whether it is con- nected to a single detector or a command module when powered up. Therefore, no changes to the SmartONE APIC are required, in order to specify the addressing mode. Note: In either mode, any change to a detector address must be made manually to the detector or SmartONE card. The control panel can not be used to change a detector's address. Single Address Mode When the interface is set to single address mode, the card is set to a single address on the SLC, and the detec- tor status is read from that address. The 2 hex switches on the SmartONE APIC card, shown as HEXI (second decimal place) and HEX2 (first decimal place), are used to specify the address. In single address mode, the address can be any value between I and 255 (inclusive). In single address mode, the address set on the detector To Detector Interface .-d Factory HEX2 (Upper HEX1 (Lower Programming Loop Address).1 Loop Address) Port Figure 1. SmartONE APIC card is ignored by the SmartONE APIC. The address set on the SmartONE APIC card will be the address that is used by the control panel. Note: If AIR-Intelligence Remote 3 software is used on the detector, the address it sees will be the address set on the detector's dip switches. Multi-Address Mode Multi-address mode is used when using a single Smart- ONE APIC card to monitor the status of multiple detec- tors on a Command Module loop. The SmartONE APIC is mounted within the Command Module. In multi-address mode, the hex switches on the Smart- ONE APIC card are not used. Instead, the address of each detector is set using the detector's dip switches. In multi-address mode, the address of each detector can be any value between 1 and 127 (inclusive). STATUS MODES The APIC card returns the following status modes, which are interpreted by the control unit: Normal PC Line Trouble Low Airflow Trouble High Airflow Trouble Detector Trouble Isolation Trouble Pre-Alarm Fire SPECIFICATIONS Input Voltage: 20.4 to 28.0 Vdc Operating Current: lOOpA Operating Conditions: Temperature: - 32°F to 120°F (0°C to 49°C) Relative Humidity: - 0-85% Dimensions: 4 in. x 2-3/4 in.(102 mm x 68 mm) - Page 17 of 25- Back to Index Ordering Info APIC in Multi- Address Mode (typical) ASD-640 ASD-320 RDLJ wi,rt ASD-160H t!hi - I _ L I II L_ - - RS-485 —* To BMS D-640 CM or ASD-CM ASD-640 ARIES NETLink Control Panel Figure 2. Fire Alarm Control Panel Interface - Multi-Address Mode APICs in Single-Address Mode (typical) L' L JT H J 5SLC Hi ASD-640 ARIES NETL!nk Control Panel Figure 3. Fire Alarm Control Panel Interface - Single-Address Mode - Page 18 of 25- mc IM Back to Index Ordering Info Loop Isolator Effective: January 2011 FEATURES Electrical Box or Detector Base Mounting Configurations Full Analog Display UL Listed FM Approved CSFM Approved ULC Approved DESCRIPTION Isolator modules are automatic switches that open a seg- ment of the signaling line circuit when a short-circuit fault is detected in that segment. The remainder of the signal- ing line circuit continues to function normally and is unaf- fected by the short-circuit fault. The isolator modules will close and resume normal operation when the short-cir- cuit fault is removed. Isolator module, P/N 74-200012-002, is supplied with a plastic cover plate for mounting to a single-gang electri- cal box. Isolator module, PIN 74-200012-004, is designed to mount in the electrical box for the Model 6SB detector base. Both types of loop isolators are fitted at convenient posi- tions to protect each individual device. The number of devices between each isolator must not exceed 30, and the maximum number of isolators that can be used per SLC is 20. LOOP ISOLATOR Figure 1. Loop Isolator, Stand Alone (P/N 74-200012-002) Figure 2. Isolator Loop, 6-inch Detector Base Mount (P/N 74-200012-004) LOOP ISOLATOR RESISTANCE Each loop isolator has a typical in-line resistance of 0.12 ohms. Therefore, on systems using loop isolators, the maximum SLC line resistance of 26 ohms must be reduced by 0.12 times the number of loop isolators before using it to calculate the maximum wire length. WIRING STYLES The loop isolator can be used with the following wiring styles: Class B, Style 4 Class A, Style 6 Class A, Style 7 Depending on the type of Loop Isolator, mount the unit to the gang box using 2 screws or twist the loop isolator onto the detector base. - Page 19 of 25- Back to Index I Ordering Info I Remote Releasing Module (RRM) Effective: January 2011 FEATURES Up to 64 RRMs Per Signaling Line Circuit Supports Both Gaseous and Pre-Action/Deluge Sprinkler Systems Triple R Protection Against Inadvertent Extinguishing-System Activation Versatile Mounting Configurations Internal Communication and External Power Supervision UL Listed FM Approved CSFM Approved DESCRIPTION The Remote Releasing Module (RRM) is a SmartOne® field device connected to the SLC of compatible control unit to provide the ability to remotely activate extinguish- ing-system control devices. The control unit's SLC sup- ports a maximum of 64 RRMs. Up to 16 RRMs can be configured for simultaneous group activation, with a max- imum of 4 groups. Release circuits are power-limited and supervised for short circuit by using an In-line Releasing-Circuit Device (P/N 06-220023-001). In the event of a ground fault, open, short or a relay contact failure, the device will transmit a trouble status to the compatible control unit. PROGRAMMING IDDOEFENWAL INC ASHLAND. MA 01721 U SA CAT. NO. 70.600100-001 INSTRUCTIONS PIN 06-236636-001 A 0 1 A B J RELEASE. POWER LIMITED w IN-LINE DEVICE SLC ALL OTHERS . POWER LIMITED INDOOR DRY LOCATION DEVICE ADDRESS - - - SOFIWARE REVISION REMOTE RELEASE MODULE (RRM) 24V0C PSU i RE SE +l - I + - + - ISTUS I INSTALLATION The RRM can be mounted in the following ways: P/N 70-600000-001 : Standard Mounting As with any SmartOne device, addressing can be imple- • North American 4-11/16 in. electrical box with a mented from the hand-held programmer (PIN 70- double gang plaster ring (Rayco Model 841 or 600000-100) or from the compatible control unit keypad equivalent), 1/2 in. raised menu. A 24VDC power supply is required for the RRM to • 4 in. square, 2-1/8 in. deep electrical box program with a hand-held programmer. P/N 70-600000-002: In-Cabinet Mounting STATUS LED • Any UL-864 Listed enclosure with no other A status LED is mounted on the unit and indicates the electronics. module's status. - Page 20 of 25- Back to Index SPECIFICATIONS CIRCUIT CHARACTERISTICS Activation: Up to 64 RRMs per SLC (Activated Consecutively) Up to 4 Groups of 16 RRMs per group (RRMs in a group activate simultaneously, groups activate con- secutively) Releasing Circuit Output Current: 2.4A Max @ 24.0 VDC Operating Voltage: 24 CVDC Nominal Trouble Circuit Input 4.7K End of Line Resistor "Open" contact = normal condition Power Consumption From Power Supply: - Normal, Standby: 6.1 mA - Alarm: 45mA From SLC: - Normal, Standby: 410 pA - Alarm: 410pA SHIPPING WEIGHT 10.50z (298g) OPERATING TEMPERATURE RANGE -32°F to 120°F, (0°C to 490C), Indoor/Dry location use only OPERATING HUMIDITY RANGE 93% ±2% RH at 90°F ±3°F (32°C ±20C), CONSTRUCTION High Impact Polymer Faceplate with a 16 gauge Alu- minum Bracket ACCEPTABLE WIRE SIZE: Terminal connections support wiring from #18 AWG to #12 AWG. Wire sizes determine electrical box depth. LED PULSE MODES: Normal, Standby: - flash at 9-second repetition rate Output Active: - On steady Trouble: —Off Ordering Info The following power supplies are compatible with the power supplies Description Manufacturer Part Number Multi-Zone Power Supply Assembly Fenwal 89.300020-001 24 VDC, 1A Aisdliary Power Output of FN6000 Control Uni, Qty 2 (See Note 1) F I 74600000-001 and 74-600000-501 24 VDC, 3A Power Supply red enclosure Altronix AL 400ULXR 24 VDC, 3A Power Supply grey enclosure Altronix AL 400ULX 24 VDC, 6A Power Supply red enclosure Altronix AL 600ULXR 24 VDC, 6A Power Supply, grey enclosure Altronix AL 600ULX 24 VDC, 8A Power Supply, red enclosure Altronix AL 1024ULXR 24 VDC, 8A Power Supply, grey enclosure Atlronix AL 1O24ULX Notes: Both auxiliary circuits may be wired together to obtain 2 A at 24 VDC. Altronix power supplies may be ordered through an authorized Altronix dealer. For a list of dealers, visit www.altronix.com or call (888) 258-7669. -Page 21 of25- Back to In Addressable Manual Pull Station Series 3300 FEATURES Unique Field Labeling for either Fire Alarm or Suppression Applications Dual Action Operation Surface and Weatherproof Backboxes Flashing LED Keylock for Reset UL Listed #S5654 FM Approved cUL Listed #7150-1076:147 DESCRIPTION The Kidde® Addressable Manual Pull Stations is an intel- ligent initiating device that contains its own SmartOneTM Addressable Input (Al) module and interfaces directly to the Kidde PEGAsysTm and ARIESTM control panels. The initiating device circuit is wired as NFPA Class B. The Manual Pull Station is constructed of heavy die-cast aluminum for long life and uses an internal toggle switch for reliable operation. Similiar to the SmartOne devices, the unit is field pro- grammable using the control panel keypad or Hand-Held Programmer. The owner location message and reporting type can be customized by the use of a programming util- ity utilized with the control panel. A status LED is mounted on the unit and indicates the status by a 2 or 9 second flash interval. A Trouble condition inhibits the sta- tus LED completely. While the Pull Station is designed for quick, efficient emergency response, its double action PUSH/PULL levers prevent accidental operation. The Pull Station can be mounted in an indoor or outdoor weatherproof backbox (Model SBG-325 or Model SGB- 32C) or a North American 2-1/2 in. (64 mm) deep single- gang box. The Station terminal block on the Al module accepts 14, 16 and 18 AWG (1.5 mm 2, 1.0 mm2, and 0.75 mm2) wire. Size #18 is the minimum requirement. FIRE ALARM OR SUPPRESSION RELEASE LABELING The Pull Station has a unique labeling method which pro- vides the installer the greatest amount of flexibility with- out the expense of having to carry extra inventory. Seven heavy-duty Lexan® self-adhesive labels are shipped with each station: Ordering Info Effective: January 2011 Kidde Fire Systems A UTC Fire & Security Company FIRE ALARM • FM-200 RELEASE NOVEC 1230 RELEASE • FE-13 RELEASE FIRE SYSTEMS • HALON RELEASE RELEASE - Page 22 of 25- Back to In Ordering into SPECIFICATIONS DIMENSIONS Station Type: Double Action, with integral SmartOne Addressable Module Initiating Device Circuit: EOL Resistor Value: - 0 K Ohm (06-129025-003) Max. Circuit Resistance: - 50 Ohm (25 ohm per conductor) Max. Circuit Capacitance: - 0.1pF Operating Temperature Range: 4-3/4 In. -40°F to 150°F (-40°C to 66°C) (121 mm) Operating Humidity Range: 0-95% RH Construction: Die-cast metal housing Compatible Electrical Boxes: Indoor: - Sheet metal Model SGB-32S Outdoor: - Weatherproof Die-cast Model SGB-32C Shipping Weight: 1.12lbs.(510g) SGB-32S INTERIOR SURFACE BACKBOX Dimensions: 4-3/4 in. Hx3-1/4 in. Wx2-1/4 in. D Construction: Steel sheet metal Conduit: Two knockouts for 1/2 in. conduit connectors, one on top and bottom Mounting: Mounts to the box with (4) 8/32 screws, which ship with each box SGB-32C WEATHERPROOF SURFACE BACKBOX Dimensions: 4-3/4 in. H x 3-1/4 in. W x 2-1/4 in. D Construction: Cast aluminum Conduit: One threaded opening for 1/2 in. conduit connector Mounting: Mounts to the box with (4) 8/32 screws and a foam gasket, which ship with each box - Page 23 of 25 - 3-1/4 in. (83 mm) 1-5/64 In. (27 mm) 1 lI I 31132 in, (57 mm) Back to Index SmartOne Intelligent Devices & Effective: January 2011 Modules Ordering Information Ordering Information DESCRIPTION PART NUMBER Distributed Intelligence Photoelectric & Ionization Smoke and Thermal Detectors Ionization Detector Model CPD 7052 70-402001-100 Photoelectric Detector Model PSD 7152 71-402001-100 Thermal Heat Detector Model THD 7252 70-404001-100 Flanged Detector Base, Model 6SB 70-400001-100 Flangeless Detector Base, Model 4SB 70-400001-101 Detector Base Adaptor Model MA-002 70-400001-200 11 Intelligent Air Duct Smoke Detector fi Duct detector with SmartOneTm Photoelectric Detector included DH-2000PSD1 70403001-152 Duct detector with SmartOneTm Ionization Detector included DH-2000CPDI 70-403001-052 Duct detector housing (without detector) 70403001-100 12 inch sampling tube (For ducts less than 2 ft.) 06-129500-001 24 inch sampling tube (For ducts between 2 and 3 ft.) 06-129500-002 48 inch sampling tube (For ducts between 3 and 4 ft.) 06-129500-003 72 inch sampling tube (For ducts between 4 and 6 ft.) 06-129500-004 96 inch sampling tube (For ducts between 6 and 8 ft.) 06-129500-005 120 inch sampling tube (For ducts between 8 and 10 ft.) 06-129500-006 Exhaust tube kit 06-129554-001 1 Addressable Contact Input Device I Addressable Contact Input Device N.O. I 70-407008-001 I I Addressable Contact Input Device N.C. I 70-407008-002 I Package of 10 End-of-Line Resistors 1 70-411001-005 AlarmLine Addressable Linear Heat Detector AlarmLine Addressable Linear Module (AAM) 73-100001-003 NEMA4 Sealed, Protective Polycarbonate Enclosure, Used to mount AAM in wet or dusty 73-100003-001 environments Standard Sensor Cable 73-117068-013 (656 ft./200 m) 73-117068-113 (3280 ft./1000 m) Nylon Coated Sensor Cable 73-117068-016 (656 ft./200 m) 73-117068-116 (3280 ft./1000 m) Bronze Braided Sensor Cable 73-117068-019 (656 ft./200 m) 73-117068-119 (3280 ft./1000 m) I Addressable Relay Output Device AO Control Module I 70-408004-001 - Page 24of25- Back to In Ordering Information (Continued) DESCRIPTION PART NUMBER Addressable Signal Module Addressable Signal Module 70-200200-003 PEGAsys Addressable Loop Module (PALM) PEGAsys Addressable Loop Module 77-297103-000 AIR-Intelligence SmartOne Addressable Protocol Interface Card (APIC) APIC 76-333002-001 Loop Isolator Loop Isolator—i Gang Box mounted 74-200012-002 Loop Isolator—Detector Base mounted 74-200012-004 Remote Releasing Module Remote Releasing Module (With Standard Bracket and Front Cover Plate) 70-600000-001 Remote Releasing Module (With In-Cabinet Bracket and Mounting Hardware) 70-600000-002 Inline Releasing-Circuit Device (One Required For Each Release Circuit to be Supervised and Power Limited) 06-220023-001 Addressable Manual Pull Station Series 3300 Addressable, Double Action Manual Pull Station Ships with mounting hardware, 2 keys, I break rod, and label set. 84-330002-001 Addressable Input Module (Normally Open Devices) 70407008-001 SGB-325 Indoor Backbox 84-100009-001 SGB-32C Outdoor Waterproof Backbox 84-100009-002 10 K Ohm Resistor 06-129025-003 Pkg. of (12) Breakrods 84-100008-002 Spare Key 06-118013-001 Label Set 06-231866-930 SmartOne® is a registered trademark of Kidde-Fenwal, Inc PEGAsys, ARIES, ARIES NETLink, and SmartOne are registered trade- marks of Kidde-Fenwal, Inc. AIR-Intelligence is a trademark of Kidde-Fenwal, Inc. Kidde is a registered trademark of Kidde-Fenwal, Inc. FM-200 is a registered trademark of the Great Lakes Chemical Corporation. 3M and Novec are trademarks of 3M. FE-1 3 is a trademark of DuPont. Lexan is a registered trademark of the General Electric Company. assumes no responsibility for the products suitability for a particular application. The prod- I fli1dde Fire Systems This literature is provided for informational purposes only. KIDDE-FENWAL, INC. I uct must be properly applied to work correctly. If VOLI need more infnrmtion on this nrodtint or if you have a n icsjtar nujestion contact I A UTC Fire & Security Company I lb-AL IN., Ashland, MA 01721. Telephone: (508) 881-2000. I 400 Main Street Ashland, MA 01721 K-76-801 Rev. AB © 2011 Kidde-Fenwal Inc. Printed in USA. - Page 25 of 25 - Ph: 508.881.2000 Fax: 508.88 1.8920 www.kiddefiresystems.com 2in.' (51 mm) 4-5/8 In. 117 mm 4-1/2 in. (114 mm) - 0 PUSH! (114 MM) 4-1/2 in. HOLD SUPPRESSION SYSTEM ABORT tfKkjdeQ 4-5/8 in. 117mm Figure 1. Dimension Details Model 878752 Suppression System Abort Station Kidde Fire Systems Effective: November 2014 K-84-10 FEATURES UL Listed Flush or Surface Mount One Normally Open Contact Sized for Double Gang Box Large Yellow Push Button Switch Abort Station Becomes Addressable SLC Device with installation of one (1) Model Al Addressable Monitor Module, N.O. DESCRIPTION The Kidde® Model 878752 Abort Station features a large, easy-to-operate abort push button. The momentary type switch is very easy to see due to its highly visible yellow color. The abort station stainless steel faceplate is clearly labeled with operation procedures—eliminating indeci- sion and hesitation. The Backbox is painted with red enamel and is provided with four 1/2-inch knockouts. The pre-drilled and tapped mounting tabs allow for easy attachment of the abort station. To make the Abort Station an addressable SLC device for use with Kidde Intelligent control units, one SmartOne® Model Al monitor module (purchased separately) must be installed into the backbox. The Model Al monitor mod- ule is seated inside a bracket (included) and easily installs with two mounting screws. A cULus-listed Abort Station for Canadian applications that require compliance to ULC S527-11 (3rd edition) is also available (blue faceplate with white raised lettering). Order P/N 84-878752-110. TECHNICAL SPECIFICATIONS Electrical Ratings: One normally open momentary contact, rated 2.5 Amps @ 120 Vdc Ambient Temperature: -13°F to 158°F (-25°C to 70°C) Terminals: Captive screws and saddle clamps accept 14 AWG to 24 AWG wire Mounting: Four 6-32 x 1/2-inch mounting screws included ORDERING INFORMATION Part Number Description Shipping Weight 84-878752-010 Abort Station 2 lb. (0.9 kg) 06-236881-001 Backbox, Red 1 lb. (0.45 kg) Model Al Addressable 5 oz. (145 g) 70-407008-001 Monitor Module, N.O. (includes bracket) Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresysfems.com This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. VQA.ifl Pa,, A(' n, )fllfl V,dd n,,,I In- Key Maintenance Switch Kidde Fire Systems A UTC Fire & Security Company Effective: May 2009 K-76-606 FEATURES cFMus Approved to ANSI/UL 864, 9th edition, CANADAIIJLC-S527 and ANSI/NFPA 72 Stainless Steel Plate Status LED Indicators Surface or Flush Mount Installations Safely Disconnects Actuation Circuits by Shorting Metron Actuators Key Operated (Nonremovable When Operated) Four-Pole Double-Throw Switch Meets the Requirements of NFPA72 (2007 edition) DESCRIPTION This Key Maintenance Switch is a key-switch that discon- nects actuation circuits in the system to prevent acciden- tal discharge of fire suppression systems during maintenance operations. The Key Maintenance Switch provides a means to short the Metron Actuator circuit leads for safe disconnection of conventional and addressable control units. Refer to the installation wiring diagram for detailed wiring connec- tions. Two LEDS indicate "SYSTEM ARMED" or "SYSTEM INACTIVE" when the key is inserted and turned. The key can only be removed in the armed position. Key Maintenance Switch mounts to a 4-inch backbox and operates on 24 Vdc. Designed for mounting on the wall with a back box. Key Maintenance Switch can be installed in either surface mount or flush mount configurations. Key Maintenance Switch physically disconnects the release circuit wiring in addition to the trouble open signal, the switch provides a means to generate a supervisory condition. ORDERING INFORMATION Part Number Description 76-600000-200 Key Maintenance Switch 06-236881-001 Backbox ELECTRICAL Switch: 4PDT Key Switch - one set of contacts control indicators on the faceplate. - Three remaining contacts are available for application wiring. Device Current: 10 A @ 250 Vac 15A@ 125 Vac 15A@ up to 30 Vdc Electrical Life: 50,000 cycles - maintained 25,000 cycles - -momentary ENVIRONMENTAL Operating Temperature 32 to 120°F (0 to 49°C) Range: MECHANICAL Mechanical Life: 100,000 cycles Switch Plate Stainless Steel Construction: This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-76-606 Rev AB © 2009 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Powering business worldwide As a global diversified power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses. Eaton's innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably. UITON Powering Business Worldwide '?C2jO 18.0 b58 4L ik j: jt NZM We deliver: Electrical solutions that use less eneigy, improve power reliability and make the places we live and work safer and more comfortable Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions We provide integrated solutions that help make energy, in all its forms, more practical and accessible. With 2012 sales of $16.3 billion, Eaton has approximately 103,000 employees around the world and sells products in more than 175 countries. I-u . M I 4 •! . I r\ Introduction For over 45 years, the TOLCOTM brand has been synonymous with innovative, labor saving pipe hanger and seismic bracing solutions for the fire protection industry. Products & Services TolBracelM Seismic Bracing Software One of the broadest lines of pipe hangers, strut and seismic bracing in the industry Fire Protection Team Our Fire Protection team actively participates in the fire protection industry, including: Membership in the NFPA Technical Committee on Hanging and Bracing of Water Based Automatic Fire Sprinkler Systems MSS 403 Standards Committee for Pipe Hanging and Seismic Bracing Product Certifications Many of the products shown in this catalog are certified with the following: Listed by Underwriters Laboratories (UL) in U.S. and Canada Factory Mutual Engineering Approved (FM) Pre-approved by the State of California, Office of Statewide Health, Planning and Development (OSHPD) as shown in our OPA-0300 Seismic Bracing Guidelines Our Fire Protection Solutions catalog is intended to aid design engineers, specifying engineers, Authorities Having Jurisdiction (AHJs) and others seeking solutions to their pipe support and seismic bracing system installations and design challenges. For more information on B-Line pipe hangers and supports, and TOLCO seismic bracing solutions utilized in other applications, such as mechanical or plumbing systems, please refer to our Pipe Hangers & Supports and Strut Systems catalogs, and the State of California OSHPD Pre-Approved Seismic Restraint Guidelines OPA-0300. These resources and other valuable information can be found online at www.bline.com. BSISince MSS c®us os)pd 1924 LISTED APPROVED Manufacturers Standardization Society of the valve and Fitting Industry, Inc. iso 9001:2008 Main Office Fire Protection Customer Service Eaton's B-Line Business Eaton's B-Line Business 509 West Monroe Street 1375 Sampson Avenue Highland, Illinois 62249-0326 Corona, CA 92879 Phone: 800-851-7415 Phone: 951-737-5599 Fax: 618-654-1917 Fax: 951-737-0330 www.cooperbline.com/fireprotection B-Line by F Fire Protection Solutions Table of Contents Fire Protection Information ..................................................2 Application Photos .......................................................................3 PictorialIndex ............................................................................4 -9 Beam Clamps Upper Attachments CeilingFlange ...........................................................................83 Angle Supports ............................................................83 -85 Swivel Attachment ..............................................................86 Bolted & Welded Clevis ...................................................87 Concrete Plates ............................................................88 -89 Threaded Accessories C-Clamps ............................................................................10 -15 Retaining Straps .........................................................16 -17 BarJoist Hanger ....................................................................18 Composite Wood Joist Clamp ..................................19 Pipe Hangers Clevis Hangers - NFPA .....................................................20 BandHangers ................................................................21 -24 SplitClamps ...............................................................................25 'U' Hangers ......................................................................26 -28 Pipe Clamps Risers................................................................................................29 Underground Clamps .............................................30 - 31 Clamps.................................................................................32-33 Straps...............................................................................................34 CPVC Hangers & Surge Restrainers ..........35 - 43 L Pipe Supports Stands..................................................................................44 -45 Supports.............................................................................46-47 Seismic Bracing Swivel Attachment & Rod Stiffeners .................48 Sway Bracing Pipe Clamps ..........................................49 Sway Brace Main Pipe Attachments ........50 -72 0 Concrete Inserts Concrete Deck Inserts ............................................ 74 -75 Spot Inserts & Insert Nuts .................................76 -79 Brackets LightDuty ....................................................................................80 MediumDuty ............................................................................81 Brackets with U-Bolts .......................................................82 0 EyeNuts ........................................................................................90 U-Bolts .................................................................................91 -93 Rods, Rod Stiffeners, Couplings, Washers & Hardware ....................................94 -103 Anchor Load Charts NFPA 13-16 - AWSD /Powers Power-Stud+Ot SD2 Seismic Wedge Anchors................................................ ........................ ALl - AL5 NFPA 13.16 - Wood-Knocker .........AL6 - AL10 ASCE 7-10 - AWSD / Powers PowerStud+t SD2 Seismic Wedge Anchors..................................................................AL11 -AL15 ASCE 7-10 - Wood-Knocker'" ........ALI6 - AL20 Reference Data Metric Conversions ............................................104 -105 Miscellaneous Charts Piping, Tubing, Threaded Rod, etc. 106 - 110 Beam Data Charts ...............................................111 -113 Trapeze Hanger Chart ......................................114-115 MSS & Federal Specification Charts .. 116- 117 B-Line Compliances & Approvals .......... 118-119 Cross References TOLCO to B-Line ...................................................120 -121 B-Line to TOLCO ...................................................122 -123 Anvil/Grinnell®t to B-Line/TOLCO ........................124 Erico®t to B-Line/TOLCO ...............................................125 PHD®t to B-Line/TOLCO .................................................126 Super Strut®t to B-Line/TOLCO ..............................127 C & P®t to B-Line/TOLCO ..................................................128 Empire®t to B-Line/TOLCO ..........................................129 Index...................................................................130 Mark shown in this document is the property of its respective owner. B-Line Fire Protection Solutions 1 by FTN m - -.r. Seismic Restraints System IT" Sel sn)-i t S System e/s/ for mechanical, e1ëEJuthIrng / and fire sprinkler syste Mrs ms..:4 f TOLBrace T11 TOLBrace Fire Protection Software Allows you to create a submittal sheet, with all relevant information, at the click of a mouse! TOLBrace TM 7.0 includes a feature that will automatically update your software, via the internet, when new products are added; when there are updates to codes and standards, and any necessary software upgrades. TOLBrace software assists a Fire Sprinkler system designer with the following: I Seismic force factor calculations (Fp) Zone of influence calculations Sway brace orientation and angle selection Structural attachment of sway braces Brace material selection Appropriate selection of UL Listed and FM Approved sway brace components Creating a submittal sheet with all relevant information with the click of a mouse! TOLBrace follows the requirements of: NFPA 13, 1999, 2002, 2007 & 2010 Uniform Building Code International Building Code National Building Code of Canada California Office of Statewide Health Planning & Development (OSHPD) Seismic Bracing Services & Products for Mechanical, Electrical and Plumbing Systems In addition to our long reputation as a provider of sway bracing products and software for the Fire Sprinkler Industry, we also provides a line of products and services directed to the installers of all other non-structural building systems. We provide: Pre-project bid assistance to contractors Assist building owner, architect and design engineer with code compliance and design questions Review and updates to product specifications Pre-Approved (OSHPD) and/or Project Specific Engineered Seismic Restraint Details Layout of Seismic Restraints on Project Drawings Product in "kit" or 'bulk" shipments to meet all project management and budget requirements Installer training Post installation jobsite inspection For more information, visit www.cooperbline.com/tolbrace. Fire Protection Solutions 3 B-Line by ET.N Pictorial Index Beam Clamps P B3O33 Fig. 68S B3037 Wide Jaw Top T Flange (3/4" Throat) Fig 65XT-3/8 Fig. 65 Z-Purlin Beam Clamp Flange C-Clamp op g Reversible Fig. 68W R 'ble Reversible C-Clamp Page 10 Page 10 Page 11 (11/4" Throat) Steel C-Clamp tee -amp Malleable, With Locknut With Locknut Reversible Beam 3/4" Throat 3/4" Throat Clamps Page 13 Page 13 Page 12 Fig. 67SS Fi. 66 Fig. 68SS Rev!rsible (14 Throat) N%4,00 Steel C-Clamp Reversible B3042 Fig. 130 With Locknut Stainless Steel Fig. 69 Fig. 69R (TOLCO 61T) Composite Wood 11/4" Throat C-Clamp Retaining Strap Retrofit Capable Bar Joist Hanger Joist Clamp Page 14 With Locknut Page 16 Retaining Strap Page 18 Page 19 Page 15 Page 17 Pipe Hangers Fig. 2 Fig. 2F Fig. 200 Fig. 200F Fig.200C B3198H Fig. INFPA Adjustable Trimline Felt Lined Plastic Coated (TOLCO 302) NFPA Felt Lined Band Hanger Adjustable Adjustable Trimline Trimline Hinged Extension Clevis Hanger Page 22 Band Han Band Hanger Adjustable Adjustable Split Pipe Clamp Page 20 Page 22 Fig. rage 21 Band Hanger Band Hanger Page 25 Fig. 200M Page 21 Page 21 - Band Hanger Figure 120 9 Metric Rod -. Hanger 'U' Sizes Page 26 Page 23 (TOLCO3O1CT) Copper Tubing Fig 200 H Hinged Extension Fig. 12OMJ Heavy Duty Clam Trapeze ___ Fig. 120W Fig. 12ORWA Split Pipe Mutt & Jeff Wrap Around Retrofit Wrap Around Page 25 p 'U' Hanger 'U' Hanger U Hanger Clamp Page 24 Page 27 Page 27 , Page 28 Band Hanger - B-Line • DURA-COPPER' Finish Fire Protection Solutions by F .N 4 B3140 (TOLCO 4) Standard Pipe Clamp Page 32 B2400 (TOLCO 2STR) Standard Pipe Strap Page 34 Fig. 25 Surge Restrainer Page 38 Fig. 22 Single Fastener CPVC Strap Page 35 Fig. 28M Offset Hanger & Restrainer for CPVC & IPS Pipe Page 41 Fig. 29 Double Offset Hanger & Restrainer for CPVC Pipe Page 42 Pictorial Index Pipe Clamps B3373 (TOLCO 6) Standard Riser Clamp Page 29 ONO, B3140C Fig. 23 Double Fastener CPVC Strap Page 37 Fig. 24 Double Fastener Side Mounted CPVC Strap Page 38 (TOLCO 4PVC) Plastic Coated Standard Pipe Clamp Page 32 Fig. 2212 B3373C j!IlIuk 1 (TOLCO 6PVC) Plastic Coated Standard Riser Clamp Page 29 B3132 B3134 (TOLCO 9) (TOLCO 14) Two-Bolt Underground Four-Bolt Underground r Clamp Page 30 Clamp Page 31 Wit B3132W (TOLCO 9X) Lug Washer Page 30 Fig. 4B Pipe Clamp For Sway Bracing Page 33 B3134W (TOLCO 14X) Washer Page 31 One Hole Hanger/Restrainer for CPVC & Steel Pipe Page 36 IkI Fig. 28 Fig. 27B Stand-Off Hanger & Speed Nut Restrainer for Page 39 CPVC & IPS Pipe Page 40 Pipe Supports B3088 (TOLCO 316) Base Stand B3088S Seismic Base Stand Pages 44 & 45 I! Fig. B3184 Light Duty Offset Hanger for CPVC & IPS Pipe Page 43 B3088T (TOLCO 3161) Threaded Base Stand B3088ST Seismic Threaded Base Stand Pages 44 & 45 83092 (TOLCO 318A) Adjustable Pipe Saddle Support With Yoke Page 46 B3093 (TOLCO 317A) Adjustable Pipe Saddle Support Page 47 Fire Protection Solutions 5 B-Line by ET.N Fig. 975 Straight Sway Brace Fitting Page 65 Fig. 980 Universal Swivel Sway Brace Attachment Pages 66 & 67 Pictorial Index Seismic Bracing AMU Ep Fig. 4L Longitudinal "In- Fig. 98E3 Fig. 4A Line" Sway Brace Rod Stiffener with Pipe Clamp For Attachment Break Off Bolt Head Sway Bracing Pages 50 & 51 Page 48 Page 49 Fig. 800 Adjustable Sway Brace Attachment To Steel Pages 54 & 55 Fig. 75 Swivel Attachment Page 48 Fig. 4LA Longitudinal "In- Line" Sway Brace Attachment Pages 52 & 53 Fig. 825 Sway Brace Attachment to Steel Pages 56 & 57 Fig. 910 Threaded Swivel Sway Brace Attachment Page 64 Fig. 828 Universal Sway Brace Attachment to Steel Pages 58 & 59 Fig. 825A Sway Brace Attachment to Steel Page 60 Fig. 906 Sway Brace Multi-Fastener Adapter Page 61 Fig. 1000 Fast Clamp Sway Brace Attachment Pages 68 & 69 Fig. 907 Multi-Angle Attachment Page 62 Fig. 1001 Sway Brace Attachment Pages 70 & 71 Fig. 909 No-Thread Swivel Sway Brace Attachment Page 63 Fig. 2002 Sway Brace Attachment Page 72 Concrete Inserts 30. Li B2500 B3014 (TOLCO 310) (TOLCO 309) B3014N Fig. 109A Light Duty Spot Insert N2500 Malleable Iron (TOLCO 309N) Concrete Deck Insert Fig. I09AF Page 78 (TOLCO 310N) Spot Insert Malleable Iron Pages 74 & 75 Concrete Insert Steel Insert Nut Page 79 Insert Nut Pages 76 & 77 Page 78 Page 79 B-Line by ET.N 6 Fire Protection Solutions B3069E (TOLCO 31-0) "0" Bracket Page 82 B3065 (TOLCO 301) Light Duty Welded Bracket Page 80 B3069W (TOLCO 31-M) Welded Knee Brace Page 82 B3066 (TOLCO 30M) Medium Duty Welded Bracket Page 81 B3205 (TOLCO 103) Machine Threaded Rod Page 94 ATR (TOLCO 99 & 100) All Threaded Rod Page 94 B3188 (TOLCO 110) Standard U-Bolt Pages 92 & 93 B3188C Plastic Coated Standard U-Bolt Pages 92 & 93 Pictorial Index Brackets Upper Attachments I WK Fig. 78 All Steel Ceiling Plate Page 83 Fig. 58 Threaded Side Beam Bracket Page 85 Fig. 50 Side Beam Bracket Fig. 56 For NFPA Rod & Tapped Side Fastener Sizing Beam Connector Page 84 Page 84 * Fig. 75 B3083 (TOLCO 305) Page 87 j B3061 (TOLCO 42) Angle Bracket Page 84 Fig. 51 Side Beam Bracket For NFPA Rod Page 83 B3085 (TOLCO 35) Rod Attachment Concrete Plate Page 88 Swivel B3083W0 Attachment (TOLCO 304) Page 86 Welded Beam Attachment B3084 (TOLCO 33) Single Lug Concrete Plate Page 89 Threaded Accessories Øç\ B501 (TOLCO 111) Light Weight U-Bolt Page 91 B3200 (TOLCO 330) Weldiess Eye Nut Page 90 Fire Protection Solutions B-Line by E.T.N (TOLCO 102) Eye Rod Page 97 Pictorial Index Threaded Accessories Fig. 98 B3213 ****v Rod Stiffener (TOLCO 105) Page 95 Coach Screw Rod B3210 400 Page 96 B32101 B3211 Fig. 98B Rod Stiffener with Break Off Bolt Head Page 95 El B3214 (TOLCO 106) Tie Bolt Page 96 B3210X B321OXL (TOLCO 102L) Linked Eye Rod Page 98 B3211X B3211XL (TOLCO 101L) Linked Welded Eye Rod Page 98 B3211 L (TOLCO 101) Welded Eye Rod Page 97 B655 (TOLCO 70) Steel Rod Coupling Page 100 B656 (TOLCO 70R) Steel Reducer Rod Coupling Page 100 B3212 (TOLCO 104) J-Bolt Page 99 B3228 (TOLCO 126) Hex Head Lag Bolt Page 99 IDS 16x2 (TOLCO 125) #16 x 2 Drive Screw Page 99 B3220 (TOLCO 71) Malleable Iron Rod Coupling Page 100 Ampr B200 B3248 (TOLCO F13-F17) (TOLCO 118) B3234 Square Washer Steel Washer Plate (TOLCO 116) Page 101 Page 101 Bevel Washer Page 101 a o (3) FFW HN FW LW (TOLCO 119) (TOLCO 113) (TOLCO 115) (TOLCO 117) Flat Fender Washer Hex Nut Flat Washer Lock Washer Page 103 HHN Page 103 Page 103 (TOLCO 114) Heavy Hex Nut Page 102 B-Line by f 8 Fire Protection Solutions Fig. 1CBS Clevis Pipe Spacer - B317OCT (TOLCO 202) Copper Tubing Adjustable Swivel Ring B3148 (TOLCO 7) Offset Pipe Clamp B31SOFL (TOLCO 20S) Flush Mount Pipe Strap B3095 (TOLCO 317) Pipe Saddle Support B3097 (TOLCO 311) Pipe Saddle With Strap 1 Pictorial Index Other Products (Refer to Pipe Hanger Catalog at www.bline.com for more information) B317OCTC Copper Tubing Plastic Coated Adjustable Swivel Ring a B3180 (TOLCO 20) Extended Leg Pipe Strap B3198R Extension Split Pipe Clamp 0 B3198RCT Copper Tubing Extension Split Pipe Clamp I B3089 (TOLCO 319) Pipe Support Adjuster B3262 Light Duty Spring Hanger B3090 (TOLCO 318) Pipe Saddle Support With U-Bolt 83064 Adjustable Strut Bracket ci B3096 (TOLCO 312) Adjustable Pipe Saddle Support 41, B3195 (TOLCO 84) I.P.S. Isolator B3195CT (TOLCO 83) Copper Tubing Isolator B3098 (TOLCO 313) Adjustable Pipe Support w/U-Bolt I B3068 (TOLCO 30) Light Duty Welded Bracket V % V Da Fig. 981 B3082 ATB (TOLCO 209) B3067 Fast-Attach (TOLCO 337) B3086 (TOLCO 123) Wedge Anchor (TOLCO 30H) Universal Swivel Single Lug (TOLCO 34) Toggle Bolt Heavy Duty Sway Brace Concrete Plate Clevis Concrete Welded Bracket Attachment Plate - (For bracing of CPVC pipe) 1 SHE H:;Hs (TOLCO 333) B3203 B3223 Isolation Spring RH Vibration Spring Combination Spring Extension Piece Offset Eye Socket Hanger Neoprene Hanger Hanger & Neoprene Fire Protection Solutions 9 B-Line by Et.N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 34 Fire Protection Solutions B-Line by FT.N Pipe Clamps B2400 - Standard Pipe Strap (TOLCO Fig. 2STR) Size Range: 1/2" (15mm) thru 24" (600mm) pipe Material: Steel Function: Designed for supporting pipe runs from strut supports. Approvals: Underwriters Laboratories Listed for B2400-3/4' thru B2400-8'. Conforms to Federal Specification WW-H-1 71 E & A-A-1 192A, Type 26 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 26. Finish: Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish Note: Ductile iron sizes available. Special "B" dimensions available on request, consult factory. Design Load 3 Design Load 1 ®TOLCO t®Us LISTED Design Load 2 Part No. Pipe Size A B C I W in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) B2400-1/2 1/2" (15) /16" (7.9) /16" (11.1) 213/16" (71.4) 10 Ga. (3.4) 1/8" (41.3) B2400-314 3/4" (20) 5/" (7.9) /16" (11.1) 3" (76.2) 10 Ga. (3.4) 1/8" (41.3) B2400-1 (25) 5/" (7.9) /i" (11. 1) 311/32" (89.7) 10 Ga. (3.4) 1/8" (41.3) B2400-11/4 11/4" (32) /16" (7.9) /16" (11.1) 33/4" (95.2) 10 Ga. (3.4) 1/8" (41.3) B2400-11/2 11/2" (48) /16" (7.9) /16" (11.1) 41/16" (103.2) 10 Ga. (3.4) 1/8" (41.3) B2400-2 (50) /16" (11.1) 11/16" (17.4) 521/32" (143.6) 1/4" (6.3) 1/8" (41.3) B2400-21/2 21/2" (65) /16" (11.1) 11/16" (17.4) 6/32" (156.3) 1/4" (6.3) 1/8" (41.3) B2400-3 (80) /16" (11.1) 11/16" (17.4) 625/32" (172.2) 1/4" (6.3) 1/8" (41.3) B2400-31/2 31/2" (90) /16" (11.1) 11/16" (17.4) 7/32" (184.9) 1/4" (6.3) 1/8" (41.3) B2400-4 (100) /16" (14.3) 11/16" (17.4) 725/32" (197.6) 1/4" (6.3) 1/8" (41.3) B2400-5 (125) /16" (14.3) 11/16" (17.4) 8/8" (225.4) 1/4" (6.3) 1/8" (41.3) B2400-6 (150) /16" (14.3) 11/16" (17.4) 915/16" (252.4) 1/4" (6.3) 1/8" (41.3) B2400-8 8" (200) /16" (14.3) 11/16" (17.4) 1131/32" (304.0) 1/4" (6.3) 1/8" (41.3) Part No. Design Load 1 Design Load 2 Design Load 3 Approx. Wt/100 Lbs. (kN) Lbs. (kN) Lbs. NN) Lbs. (kg) B2400-1/2 600 (2.67) 150 (.67) 105 (.47) 23 (10.4) B2400-3/4 600 (2.67) 150 (.67) 105 (.47) 26 (11.8) B2400-1 600 (2.67) 150 (.67) 120 (.53) 31 (14.0) B2400-11/4 600 (2.67) 150 (.67) 120 (.53) 36 (16.3) B2400-11/2 600 (2.67) 150 (.67) 120 (.53) 39 (17.7) B2400-2 1200 (5.34) 480 (2.14) 180 (.80) 93 (42.2) B2400-21I2 1200 (5.34) 480 (2.14) 180 (.80) 106 (48.1) For larger sizes, B2400-3 1200 (5.34) 480 (2.14) 300 (1.33) 132 (59.9) consult the full B2400-31/2 1200 (5.34) 480 (2.14) 300 (1.33) 151 (68.5) line pipe hanger B2400-4 1500 (6.67) 600 (2.67) 450 (2.00) 160 (72.6) catalog. B2400-5 1500 (6.67) 600 (2.67) 450 (2.00) 192 (87.1) B2400-6 1500 (6.67) 600 (2.67) 450 (2.00) 219 (99.3) B2400-8 2000 (8.90) 800 (3.56) 600 (2.67) 297 (134.7) Pipe Clamps Fig. 22 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Single Fastener Strap (B-Line B3181) Size Range: 3/4 (20mm) thru 2 (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Fig. 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm) steel using (1) 1/4" xl tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design protects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size. * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. ®TOL.CcT c®US USTED CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size W000 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 22-/4 3/4 (20) 2/16 (61.9) 1/16 (33.3) 1/16' (30.2) 51/2 (1.67) /16" (7.9) 9 (4.1) 22-1 1 (25) 211/16 (68.3) 1/16" (36.5) 13/16"(30.2) 6 (183) /16 (7.9) 9 (4.1) 22-11/4 11/4 (32) 31/16 (77.8) 1/8 (42.3) 1/16 (30.2) 61/2 (1.98) /16 (7.9) 11 (5.0) 22-11/2 11/2 (40) 3/16 (84.1) 1/4 (44.4) 1/16 (30.2) 7 (2.13) /16 (7.9) 12 (5.4) 22-2 2" (50) 33/4 (95.2) 21/8 (54.6) 1/16° (30.2) 8 (2.44) /16" (7.9) 15(6.8) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 35 by ET.N ®TOLCQ All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 36 Fire Protection Solutions B-Line by fT.N Pipe Clamps Fig. 2212 - One Hole Hanger/Restrainer for CPVC & Steel Pipe Size Range: 3/4 (20mm) thru 2 (50mm) CPVC & steel pipe Material: Pre-Galvanized Steel Function: cULus Listed to perform as a hanger and restrainer for CPVC or (PS piping systems. The innovative design also allows for a preferred installation location close to a CPVC fitting without applying damaging compression forces on the pipe which could result in serious Mechanical ESC (Environmental Stress Cracking). Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUI} to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm) steel using (1) 1/4° x 1 tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Installation Note: Comes in open position for easier installation. Because of multi - structural installation possibilities, specific fastener not included; see notes below for various applications. For Concrete Installation - UL requires a minimum test load of 340 lbs for CPVC hangers and 750 lbs for steel pipe hangers; verify anchors meet or exceed these requirements. For Wood Installation - Test results have shown that #14 x 11/2" wood screws will support the required load for c UL us. For Steel Installation - Test results have shown that 1/4" x 1" (mm. 20ga steel) Tek type screw will support required UL load. Finish: Pre-Galvanized Order By: Part number Patent Pending Hanger/Restrainer Tab Down 1'------ or Tab Up - Head Pipe PipeOD Hanger/Restrainer L....._. Fitting OD Mounting Surface Offset Design CPVC or Steel Max. Hanger Max. Hanger Approx. Pipe Size A B C Spacing - CPVC Spacing - Steel Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) R. (m) R. (m) Lbs. (kg) 221.2-3/4 3/4' (20) 2/16 (55.6) 15/16 (23.8) 3/4 (19.0) 51/2 (1.67) NA (NA) 9 (4.1) 221.2-1 1' (25) 21/2 (63.5) 11/8 (28.6) 3/4' (19.0) 6 (1,83) 12 (3.66) 9 (4.1) 221.2-11/4 11/4" (32) 213/16' (71.4) 11/4 (31.7) 3/4" (19.0) 61/2 (1.98) 12 (3.66) 11 (5.0) 2212-11I2 11/2" (40) 31/8" (79.4) 1/16' (36.5) 3/4' (19.0) 7 (2.13) 15 (4.51) 12(5.4) 2212-2 2 (50) 3/16" (90.5) 1/8° (41.3) 3/4" (19.0) 8 (2.44) 15 (4.51) 15(6.8) Pipe Clamps Fig. 23 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** ®TOLCO Double Fastener Strap (B-Line B3182) c us Size Range: 3/4 (20mm) thru 3' (80mm) CPVC pipe LISTED Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) sizes 3/4 (20mm) thru 2(50mm) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm) steel using (2) 1/4' x 1' tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. Part No. CPVC Pipe Size in. (mm) A in. (mm) B in. (mm) C in. (mm) Max. Hanger Spacing Ft. (m) Fastener Hex Head Size in. (mm) Approx. Wt./100 Lbs. (kg) 23-/4 3/4 (20) 31/8' (19.4) 1/16' (39.7) 1/16 (30.2) 51/2 (1.67) /16 (1.9) 9 (4.1) 23-1 1' (25) 3/8' (85.7) 111/16 (42.9) 1/16 (30.2) 6 (1,83) /16' (7.9) 9 (4.1) 23-11/4 11/4' (32) 4/16 (106.4) 2/32 (53.1) 1/16' (30.2) 61/2 (1.98) /16 (1.9) 11 (5.0) 23-11/2 11/2 (40) 4/16 (112.7) 2/32 (56.3) 13/16" (30.2) 7 (2.13) /16 (7.9) 12 (5.4) 23-2 2' (50) 4/8' (123.8) 2/i' (61.9) 1/16' (30.2) 8 (2.44) /16' (7.9) 15 (6.8) 23_21/2 21/2' (65) 5/8' (136.5) 211/16 (68.3) 13/16"(30.2) Consult Factory /16 (1.9) 22 (10.0) 23-3 3' (80) 6 (152.4) 3' (76.2) 1/16 (30.2) Consult Factory /16' (1.9) 25 (11.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 37 B-Line by j4J ®TOLCO c®Us LISTED All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions B-Line by FT.N Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line B3183) Size Range: 3/4 (20mm) thru 2 (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support lire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4' x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the I .3 product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact r tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size W000 Part No. in. (mm) in. (mm) in. (mm) in. (mm) R. (m) in. (mm) Lbs. (kg) 24-/4 3/4' (20) 2/1 (58.7) 1/32" (21.8) 1/16" (30.2) 51/2 (1.67) /i' (7.9) 9 (4.1) 24-1 1" (25) 2/8' (66.7) 1/16' (33.3) 1/16" (30.2) 6 (1.83) /16" (7.9) 9 (4.1) 24-1/4 11/4 (32) 3' (76.2) 11/2' (38.1) 1/16" (30.2) 61/2 (1.98) /16' (7.9) 11 (5.0) 24-11I2 11/2 (40) 31/4 (82.5) 1/8' (42.3) 1/16' (30.2) 1 (2.13) /16" (7.9) 12 (5.4) 24-2 2' (50) 311/16" (93.7) 121/32" (4.3.6) 1/16' (30.2) 8 (2.44) /16" (1.9) 15 (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4' (20mm) thru 2" (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4 (20mm) thru 2 (40mm). Patent #5,344,108 IcUs USTED 1. Fig. 27B (2) Required II II II S II II II II II a II II - II II II II II II II II II LL_ Ji Hanger and Restraint Application ,,.... 55 fl 11 II II II S 11 Fig. 27B (2) Required S S I .11 'II S S III S 0 III II II II II II LL_ Ji Hanger and Restraint Application All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 39 B-Line by f'N Pipe Clamps ®TOLCO Fig. 27B — Speed Nut Size Range: - Fits screws supplied with all CPVC hangers. Material: - Steel Finish: - Pre-Galvanized (Zinc) Function: - To be used anywhere a screw cannot achieve full embedment due to thickness of wood structural material when installed. Fig. 27B allows full pull out load capacity of screws when installed to the standard screws supplied with all CPVC hangers (Fig. 22, 23, 24, 28, 28M, 29, and B3184). Fig. 27B (fl Required High II II II II Side of Hanger I II I II Application II II II II II II II II II -i II 1:1 II II II II II II II Hanger Application ,- I' n--li III I\ II II II II '1 II II I) --ell I ' 0 S II S \ K Fig. 27B S I L (1) Required High Side S II S •I I.. of Hanger Application S - III S II II II II II II II LL_ _U Hanger Application C®US LISTED All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 Fire Protection Solutions B-Line by Pipe Clamps Fig. 28 - "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe ** ®TOLCO Size Range: - 3/4' (20mm) through 2 (50mm) Material: - Steel, Pre-Galvanized Function: - Designed to be used as a hanger and restrainer for CPVC piping where the stand-off design will ease installation by eliminating the need for wood blocking. Features: Flared edge design protects CPVC pipe from any rough or abrasive surfaces. Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. The Stand-Off design eliminates the need for wood block extension. Can be installed on horizontal or vertical piping regardless of mounting surface orientation. Attaches easily to wood structure with two hex head self-threading screws furnished with product. Installs easily using rechargeable electrical driver with /16' (7.9mm) extension socket eliminating impact tool damage to pipe. Attaches easily to steel, minimum 18 gauge (1.024mm) with (2) 1/4' x 1 tek type self drilling tapping screws. UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals: - Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4' x 1' tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on /8 (9.5mm) composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by: - Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 ** With reduced spacing, consult factory. I Fig. 27B ri (1) Required High Side of Hanger Application Li Hanger Application Fig. 27B fl (2) Required Lj Hanger and Restraint Application Pipe Size A B C Max Hanger Approx. Spacing wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) R. (m) lbs. (kg) 28-/4 3/4' (20) 31/32' (77.0) 2 (50.8) 31/2 (88.9) 51/2 (1.67) 18 (8.1) 28-1 1" (25) 3/16" (84.1) 2/16" (55.6) 31/2' (88.9) 6 (1.83) 21 (9.5) 28-11M 1'/4" (32) 3/8" (92.1) 2/8" (60.3) 31/2' (88.9) 61/2 (1.98) 23 (10.4) 28-11/2 11/2' (40) 4' (101.6) 21/2" (63.5) 31/2' (88.9) 7 (2.13) 31 (14.0) 28-2 2" (50) 41I2" (114.3) 211/16' (68.3) 3/8" (92.1) 8 (2.44) 34 (15.4) C® 11$ LISTED Fig. 27B (2) Required Hanger and Restraint Application Pipe Clamps Fig. 28M - Offset Hanger & Restrainer for CPVC Plastic Pipe and lPS Steel Pipe ** ®TOLCc Size Range: 3/4' (20mm) thru 2' (32mm) Material: Steel, Pre-Galvanized Function: Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: Flared edge design protects CPVC pipe from any rough or abrasive surfaces Unique snap-on design holds pipe firmly in place and allows retrofit type of installation The "Stand-Off" design eliminates the need for wood block extension Can be installed on horizontal or vertical piping regardless of mounting surface orientation Attaches easily to wood structure with two hex head self-threading screws furnished with product Installs easily using rechargeable electrical driver with /16" (7.9mm) extension socket eliminating impact tool damage to pipe 'Attaches easily to steel, minimum 18 gauge (1 .024mm) with (2) 1/4" x 1" tek type self drilling tapping screws cULus Listed as a hanger and a restrainer for fire sprinkler piping Installation Note: When installed in wood structural members and threads from the #10 x 1" screws are exposed, use Fig. 27B speed nut to secure Approvals: Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical .. restraint requirements where needed. Order By: Figure number and pipe size ,¼ Patent #7,744,042 ** With reduced spacing, consult factory. Part No. Pipe Size in. (mm) A in. (mm) Hole Dia. B in. (mm) C in. (mm) Max spacing' in. (mm) Approx. WtJ100 lbs. (kg) 28M-3/4 3/4' (20) 2" (50.8) /16" (4.8) 3/16' (84.1) 5'-6" (1676) 9 (4.1) 28M-1 1" (25) 21/8' (54.0) /16' (4.8) 31/2" (88.9) 6'-0" (1829) 12 (5.4) 28M-11/4 11/4' (32) 2/16 (58.7) /16" (4.8) 31/2" (88.9) 6'.6" (1981) 13 (5.9) 28M-11/2 11/2' (49) 21/16" (61.9) /16" (4.8) 37/8" (98.4) 1'-0" (2133) 14 (6.3) 28M-2 2' (50) 2/8" (66.7) /16" (4.8) 4/16' (112.7) 8'-0" (2438) 15 (6.8) * Required per NFPA 13 for CPVC plastic pipe All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 41 by FT.N . 4 --- ___ _j V Restraint Fig. 27B (1) Required High Side of Hanger DetailA Hanger Application lE ha. 1.5 (38.1mm) -I Double Offset All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 42 Fire Protection Solutions B-Line by f'1.N Pipe Clamps Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe** ®TDLCO /0 0 Size Range: Available in 3/4' 120mm1 and 1" (25mm) pipe sizes Material: Pre-Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-f it attachment of hanger to sprinkler pipe. Features: Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. Offset edge eliminates abrasion. Attaches easily to wood structure with two special #10 x 1"hex head self-threading screws furnished with product. Can be used as a single offset hanger by aligning "dimples' with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre-Galvanized Order By: Figure number and pipe size. Patent Pending ** With reduced spacing, consult factory. I 1.5" (38.1mm) ------------ 1.5" (38.1mm) Single Offset Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self-tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. Pipe Size Pipe Clamps B3184 - Offset Hanger for CPVC Plastic Pipe and IPS Steel Pipe Size Range: 3/4" (20mm) thru 2' (32mm) Material: Pre-Galvanized Steel Function: Designed to be used as a hanger for CPVC piping or steel piping where the stand-off design will ease installation by eliminating the need for wood blocking. Features: Flared edge design protects CPVC pipe from any rough or abrasive surfaces The stand-off design eliminates the need for wood block extension Can be installed on horizontal or vertical piping regardless of mounting surface orientation Attaches easily to wood structure with two hex head self-threading screws furnished with product cULus Listed as a hanger for fire sprinkler piping Installation Note: When installed in wood structural members and threads from the #10 x 1" screws are exposed, use Fig. 27B speed nut to secure Approvals: Underwriters Laboratory Listed in the USA JUL) and Canada (cUL) 3/4' (20mm) thru 2' 150mm1 to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Order By: Figure number and pipe size ®TOLCD c® USTED Patent # 7,744,042 CPVC I H Max. Hanger Fastener Hex Approx. Pipe Size Overall Overall Spacing Head Size wt./100 Part No. in. (mm) in. (mm) in. (mm) ft. (ml in. (mm) Lbs. (kg) B3184-3/4 3/4" (20) 2/16 (65.1) 41/4' (107.9) 51/2 (1.67) /16" (7.9) 9.0 (4.1) B3184-1 1' (25) 211 /16" (71.4) 41/2" (114.3) 6 (1,83) /16" (7.9) 10.0 (4.5) B3184-11/4 11/4 (32) 3/16" (81.0) 4/8 (117.5) 6 /2 (1.98) /16 (7.9) 12.0 (5.4) B3184-11/2 11/2 (40) 3/i" (87.3) 5' (127.0) 7 (2.13) /16' (7.9) 12.0 (5.4) 63184-2 2" (50) 3/8" (98.4) 5 (127.0) 8 (244) /16" (7.9) 15.0 (6.8) This product is cULus Listed as a hanger ONLY. For hanger and restraint applications, please refer to B-Line Fig. 28 (page 39) or Fig. 28M (page 40). All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 43 B-Line by f'N CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1076:0504 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: temll.garland@kidde-fenwal.com DESIGN: Models DS-SB and DS-RB detector bases Model DS-SB is a standard base and Model DS-RB is a relay base. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30 Vdc, IA INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's Model DS-PS (CSFM# 7272-0176:0502) and Model DS-HFS (CSFM# 7272-0176:0503) detectors. Refer to manufacturer's Installation Manual for details. 11-02-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-1076:0503 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrill.garIandkidde-fenwaI.com DESIGN: 11 (Model DS-HFS fixed temperature heat detecto! Fixed alarm set point is between 129°F to 144°F. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a fixed temperature heat detector for use with listee's separately listed compatible fire alarm control unit Model ARIES (CSFM# 7165-1076:0183), Model FENWALNET 6000 (CSFM# 7165-1076:0184), Model FENWALNET 8000-ML (CSFM# 7165-1076:0194, Model ARIES NETLink (CSFM# 7165-1076:0195), Model MICRO SLX (CSFM# 7165-0061:0153), Model MICRO MLX (CSFM# 7165-0061:0155). Refer to manufacturer's Installation Manual for details. 09-08-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1076:0502 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: ternll.garlandkidde-fenwal.com DESIGN (Model OS-PS Addressable photoelectric smoke detector's Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control unit Model ARIES (CSFM# 7165-1076:0183), Model FENWALNET 6000 (CSFM# 7165-1076:0184), Model FENWALNET 8000-ML (CSFM# 7165-1076:0194), Model ARIES NETLink (CSFM# 7165-1076:0195), Model MICRO SLX (CSFM# 7165-0061:0153) and Model MICRO MLX (CSFM# 7165-0061:0155). The panel programming limits for this device are from 0.9-3.5 percent perfoot obscuration for velocities from 0-300 ftlmin.and 0.9-2.00 percent per foot obscuration for velocities from 300-4000 ft/mm. including installation inside ducts. Refer to manufacturer's Installation Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 09-08-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1076:0183 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terriIl.garlandkidde-fenwal.com DESIGN: Model ARIES fire alarm control unit. Automatic, manual, local, central station, waterfiow, sprinkler supervisory and releasing device services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: 76-600000-001 ARIES Control Unit 76-600000-004 Motherboard 76-600000-011 Keypad/Display 06-118394-002 Power Supply 06-220023-001) 'In-Line Releasing Device (EOLD) 76-600000-002 Enclosure *76600000009 Network Interface Card RATING: Primary: 120/240 VAC, Standby: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a fire alarm control unit for use with listee's separately listed electrically and functionally compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 06-02-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1076:0195 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrill.garlandkidde-fenwal.com DESIGN: Model Aries NetLink Fire Alarm Control U4 Power limited. Local, releasing, auxiliary, automatic, manual, waterfiow and sprinkler supervisory services. Refer to listee's data sheet for detailed product description and operational considerations. System components: 06-220270-001 MCB (Main Control Board)/Ul (User Interface) 76-800020-001 MCB (Main Control Board) 76-800020-002 UI (User Interface) 76-800030-003 PowerSupply/Charger 76-800030-004 PMU (Power Management Unit) 76-800010-001 Expansion Backplane Module 76-800011-001 SLC (Signaling Line Circuit) Module 76-800012-001 Relay Module 76-800013-001 NAC (Notification Appliance Circuit) Module/RNAC (Release Module) 76-800016-001 City-Tie Module 76-800020-003 LAM (LED Annunciator Module) 76-800000-004 Inline Releasing Device 76-800400-001 Retrofit Enclosure Kit 76-800100-003 3-Tiered Expansion Enclosure 76-800200-003 2-Tiered Expansion Enclosure 76-800101-002 3-Tiered Canadian Application Enclosure with LAM 76-800201-002 2-Tiered Canadian Application Enclosure with LAM 76-800101-001 3-Tiered Canadian Application Enclosure without LAM 76-800201-001 2-Tiered Canadian Application Enclosure without LAM 76-800101-005 3-Tiered Dead Front 76-800201-005 2-Tiered Dead Front *76..800014..001 *NIC (Expansion Card) *76800015001 *DACT (Dialer Module) *76800017001 *1CM (Internet Communications Module) RATING: Primary: 120/240 VAC, Standby: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. *Rev 06-24-12 gt T This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1076:0195 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a fire alarm control unit for use with listee's separately listed electrically and functionally compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 06-24-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1076:0144 Page 1 of 2 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrill.garlandkidde-fenwal.com DESIGN: Control Unit Accessories. Refer to listee's data sheet for additional detailed system description and operational considerations. Mode 70-407008-001and 70-407018-001; normally-open contact input devices *Models 70-417008-001 and 70-417018-001; normally-open contact input devices *Module 70-417008-002; normally-closed contact input devices Models 70-407008-002 and 70-407018-002; normally-closed contact input devices ,Models 70-408004-001and 70-408014-001; addressable relay output devices Model 30-472001-000; remote trouble indicating panel Model 74-200041-001; limiting resistor Models 74-200012-001, 74-200012-002 and 74-200012-004; loop isolators Models 89-100081-001 AIM (AnaLASER Interface Module) and 89-100083-001 lIM-2000 (Stand Alone) Models 70-200200-001 and 70-200200-003 ASM (Addressable Signal Sounder Module), 73-100001-003 AAM (Addressable AlarmLine Module), 73-100003-001 AAM; NEMA 4 Enclosure, Models 74-800300-001, *76800300001; RDCMs (Remote Display Control Modules) Models 74-800300-101 and *76800300101; RDM (Remote Display Modules) Enclosures Models 74-300004-032 and 76-200004-032 ATM-L; (Annunciator Driver Modules) Models 74-300005-032, and 76-200005-032 ATM-R; (Relay Driver Modules) Models 74-100017-001, 76-100010-001, 74-600000-014, and 74-600000-514; Battery Boxes. Models 74-600000-006, 74-600000-516 and 76-600000-006 Fiber-Optic Converter Cards (0CC) Models 06-220171-001 thru -007; Compensating Resistors. Models 70-600000-001 and 70-600000-002; Remote Releasing Modules Models 30-330002-001and 84-330002-001; Addressable Manual Pull Stations. For indoor use with Model SGB-32S back box or outdoor use with SGB-32C back box. RATING: Electrical: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: *Listed as control unit accessories for use with listee's separately listed fire alarm control *Revision 10-17-2018 dcc ø This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7300-1076:0144 Page 2 of 2 units. Refer to listee's Installation Instruction Manual for details. *Revision 10-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: VIadimir.Kireyevhoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure "Models P4R P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Ustee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division PIW 0 1 t~" 11 - 6 - , R—r. 7— r Frt2-0t8 --0569 Fss SYSTEM . SENSOR® Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrkertO Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNAUNC 4jMEA A LISTED APPROVED approved 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) 3023572 MEA452-05-E chime strobes) S5512 (strobes) 7135-1653:189 (horns, chimes) SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6-L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3'D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7-L x 4.8'W x 0.35"D (145 mm L x 122 mm W x 9 m D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15175 cd. UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard) 15 123 128 66 71 çandela 115/75 142 148 77 81 Range 30 NA NA f94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 185 NA NA 286 258 Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 !Non-temporal jmedi6m 42 50 160 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DC Input 8-17.5 Volts 15 15175 16-33 Volts 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions Wall-mount horn strobes SpectrAlert Advance Ordering Information IModel FT!Description Wall Horn Strobes Wall Strobes (cont.) P2R 2-Wire Horn Strobe, Standard cd, Red SRH Strobe, High cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain SRH-P Strobe, High cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" SRH-SP Strobe, High cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red SW Strobe, Standard cd, White P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain SW-P Strobe, Standard cd, White, Plain P2W 2-Wire Horn Strobe, Standard cd, White SWH Strobe, High cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain SWH-P Strobe, High cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White Horns P2WH-P 2-Wire Horn Strobe, High cd, White, Plain HR Horn, Red P4R 4-Wire Horn Strobe, Standard cd, Red HW Horn, White P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain Accessories P4RH 4-Wire Horn Strobe, High cd, Red TR-HS Trim Ring, Wall, Red P4W 4-Wire Horn Strobe, Standard cd, White SBBR Indoor Surface Mount Back Box, Red Wall Strobes SBBW Indoor Surface Mount Back Box, White SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, 'FUEGO" Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. }.V57p4 3825 Ohio Avenue • St. Charles, IL 60174 02014 System Sensor. s$ SENSOR* Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change wOhout notice. Visitsysternsensorcom for current product information, including the latest version of this data sheet. www.systemsensor.com AvOS10201 • 1/14 SYSTEM $ SENSOR Audible Visible Accessories System Sensor offers a wide range of Audible Visible (A V) accessories to enable you to meet a variety of application requirements. Features MP120K Mounting Plate Designed for both indoor and outdoor use Plug-in design eliminates ground faults Power supply that converts 120 VAC to nominal 24 V FWR Compatible with all two-wire SpectrAlert Advance® devices Color Lens Attachments Easily turns any device into a strobe for ECS/MNS events: severe weather, toxic gases, sprinkler activation and more Outdoor rated from -35°F to 151°F Wall- or ceiling-mount lenses available UL 1638 listed WTP Weatherproof Plates Enables flush mounting of outdoor devices to brick, ceramic tile, concrete, and masonry brick Weatherproof NEMA 3R rated For use in both indoor and outdoor applications For use with all K-R series (outdoor) products replacement models Universal mounting plate easily attaches to the weatherproof plate Agency Listings ®ØMEA @ S' LISTED approved S4011 7300-1653:0195 582-06-E S3593 7300.1653:0204 7300.1653:0222 The MP120K Mounting Plate is designed to use 120 VAC to power SpectrAlert Advance horns, strobes, horn strobes, chimes, and chime strobes. Color Lens Attachments install easily on any indoor or outdoor SpectrAlert Advance strobe devices to provide distinctive visual signaling. WTP Series Weatherproof Plates enable installers to flush mount outdoor horns, strobes, horn strobes, speakers, and speaker strobes to a variety of wall surfaces, including brick, ceramic tile, concrete, and masonry brick. These NEMA 3R-rated plates come in red and white to suit aesthetic and functional requirements. Compatible with our outdoor devices, which can be used in indoor and outdoor environments, as required by conditions. They easily attach to the SpectrAlert Advance universal mounting plate. Trim Rings for speakers and speaker strobes allow for additional space within the backbox. Trim ring for horns, strobes, and horn strobes allow 4-wire devices to mount to a single-gang back box. SpectrAlert Advance Outdoor Back Boxes ensure a NEMA 4X weatherproof listing for AV devices. In locations where you have a hard surface to mount to, Surface Mount Back boxes are the best solution. If you have an exposed junction box, the Back Box Skirts offer an attractive solution to mask the junction box exposure. Retrofit Plates cover paint outlines on the wall when replacing legacy SpectrAlert Advance products. SpectrAlert Advance DECALS are for use on our non-pad printed wall- and ceiling-mount devices. Each decal comes with AGENT, EVAC, ALERT, or FIRE label options. The Sync.Circult Module synchronizes SpectrAlert Advance strobes at 1 Hz and horns and chimes at temporal 3 over a single pair of wires. Patented module technology also allows the silencing of horns or chimes on horn strobe and chime strobe models over a pair of wires. See the Sync.Circuit Datasheetfor more information. Specifications 120 VAC mounting plate model MP120K shall be listed to UL 464 for fire protective signaling systems. The mounting plate shall power a two-wire SpectrAlert® Advance horn, strobe, horn strobe, chime or chime strobe from a 120 VAC supply converted to nominal 24 V FWR. For indoor applications, the mounting plate shall be installed in a 4x4x21/8 -inch junction box. For outdoor applications, the mounting plate shall be installed using the proper SpectrAlert Advance outdoor weatherproof back box and outdoor listed notification appliance. MP120K may be used with any of the following products at all horn and strobe settings: P2R, P2RH, P2RK, P2RHK, P2W, P2WH, SR, SRH, SRK, SRHK, SW, SWH, PC2R, PC2RH, PC2RK, PC2RHK, PC2W, PC2WH, SCR, SCRH, SCRK, SCRHK, SCW, SCWH, HR, HRK, HW, P2RK-P, P2RHK-P, P2WK-P, P2WHK-P, SRHK-P, SWK-P, SWHK-P, SR-P, SW-F, SRH-P, SWH-P, P219-P, P2W-F, P2RH-P, P2WH-P, SCW-P, SCRH-P, PC2R-P, PC2W-P, PC2WH-P, SR-SF, P2R-SP, CHR, CHW, CHSR, CHSW. Physical/Operating Specifications Standard Operating Temperature —40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Nominal Voltage Regulated 120 VAC Operating Voltage Range 96-132 VAC Current Draw From AC Line 150 mA max. WTP Weatherproof Plates The SpectrAlert Advance weatherproof plate for horns, strobes, and horn strobes shall mount to 4x4x11/4-inch and 2x4x11/2-inch back boxes. The weatherproof plate for speakers and speaker strobes shall mount to 4x4x21/e-inch back boxes. The weatherproof plate may be installed on brick, concrete, ceramic tile, and masonry brick and must be used with System Sensor 'K-R" series outdoor replacement models. Outdoor SpectrAlert Advance products shall operate between -40°F and 151°F I'IrnI-1TT1trn1.I1- Speaker Strobe 7.25" Lx 6.26" W x 3.00" D (including speaker and lens) Speaker 7.25" Lx 6.26" W x 1.30" D (including speaker) Horn Strobe 6.90" Lx 5.90" W x 2.80" D (including strobe lens) Horn 6.90" Lx 5.90" W x 1.60" D (including horn) Note: WIP and WTPW are compatible with 4x4x11/4-inch and 2x4x11/2-inch back boxes. (Compatible with outdoor horns, horn strobes and strobes) WTP-SP and WTP-SPW are compatible with 4x4x21/e-inch back boxes. (Compatible with outdoor speakers and speaker strobes) Models Available for Use with the Weatherproof Plates: WTP HRK-R, P2RK-R, P2RHK-R, P4RK-R, SRK-R WTPW P2WK-R, P2WHK-R, SWK-R, SWHK-R WTP-SP SPRK-R, SPSRK-R WTP-SPW SPWK-R, SPSWK-R Note: K-R models ship without the outdoor back box. The weatherproof mounting plates are designed to be used only with K-R replacement models. Specifications The System Sensor SpectrAlert Advance colored lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with plain (no FIRE" print) System Sensor strobe devices. The lens shall mount to any wall- or ceiling-mount strobes and shall be rated from —35°F to 151°F Colored lens attachments may be used with the following System Sensor plain (non-FIRE-printed) indoor or outdoor strobe models: SR-P, SRH-P, SW-P, SWH-P, P2R-P, P2W-F, P2WH-P, P4R-P, P4W-F, P2RK-P, P2RHK-P, SCW-P, PC2R-P, PC2W-P, PC2WH-P, SPSW-P, SPSR-P, SPSWH-P, SPSRH-P, SPSRV-P, SPSCW-P, SPSCWH-P, SPSCWV-P, SPSCWVH-P, SPSCWHK-P, SRK-P, SRHK-P, SWK-P, SWHK-P, P2WK-P, P2WHK-P, SPSWK-P, SPSRK-P, SW-CLR-ALERT, SCW-CLR-ALERT, SPSCW-CLRALERT, SEP-SW-P, SEP-SPSW-P. Colored Lens Installation Installation to Wall-Mount Strobe Installation to Ceiling-Mount Strobe Candela Rating for UL 1638 Light output of color lenses is measured per UL 1638, on axis, and is not derated. Candela Switch Setting On-Axis Candela Rating (UL1638) -All Colors 15 15 15/75° NA 30 30 75 75 95 95 110 110 115 115 135 135 150 150 177 177 185 185 * 15/75 Candela setting not to be used with color lenses Ordering Information (continued) U1il(. Metal Weatherproof Backboxes MWBBW white, wall-mount, compatible with: SPWK-R, SPWK, SPSWK-R, SPSWK-P, SPSWK, SPSWK-CLR-ALERT MWBB red, wall-mount, compatible with: SPRK-R, SPRK, SPSRHK, SPSRK-P, SPSRK, SPSRK-R MWBBCW white, ceiling-mount, compatible with: SPCWK, SPSCWK,SPCWK-R, SPSCWK-R, SPSCWHK, SPSCWHK-R SA-WBBW white, wall-mount, compatible with: P2WK, P2WHK, P2WHK-P, P2WK-P, SWK, SWK-R, SWK-P, P2WHK-R, P2WK-R, SWHK, SWHK-P, P4WK SA-WBB red, wall-mount, compatible with: P2RK, P2RK-P, P2RK-R, SAK, SRK-P, SRK-R P2RHK, P4RK, P4RHK, SRHK, HRK, P2RHK-R, P2RK-R, HRK-R, P4RHK-R, P4RK-R SA-WBBC red, ceiling-mount, compatible with: SCRK, SCRHK, PC2RK, PC2RHK SA-WBBCW white, ceiling-mount, compatible with: PC2WK, PC2WHK, PC4WK, SCWK, SCWHK Surface Mount Back Box SBBR red, wall-mount, compatible with: HR, CHR, SR, SR-SP, SRH, P2R, P2R-SP, P2RH, P4R, P4RH, CHSR, P2R-P, SR-P, SRH-P SBBW white, wall-mount, compatible with:HW, CHW, SW, SWH, P2W, P2WH, P4W, P4W-P, CHSW, P2W-P, P2WH-P, SW-P, SWH-P, SW-ALERT, SWH-ALERT SBBSPR red, wall-mount, compatible with: SPA, SPAy, SPSR, SPSRH, SPSRV, SPSR-P, SPSRH-P, SPSRV-P SBBSPW white, wall-mount, compatible with: SPW, SPWV, SPSW, SPSWH, SPSV\Pv SPSW-P, SPSWH-P, SPSW-ALERT, SPSW-CLR-ALERT SBBCR red, ceiling-mount compatible with: SCR, SCRH, PC2R, PC2RH, PC4R, PC4RH, SPCR, SPCRV, SPSCR, SPSCRH, SPSCRV, SPSCRVH, PC2R-P SBBCW white, ceiling-mount, compatible with: SCW, SCWH, PC2W, PC2W-SP, PC2WH, PC4W, SPCW, SPCWV, SPSCW, SPSCWH, SPSCWV, SPSCWVH, PC2W-P, PC2WH-P, SCW-P, SPSCW-P, SPSCWH-P, SPSCWHK-P, SPSCWV-P, SPSCWVH-P, SPSCW-CLR-ALERT, SCW-CLR-ALERT Back Box Skirts BBS-SP201W Surface-mount back-box skirt for the PF24V (ExitPointTM Directional Sounder with Voice Messaging) SEP-BBSW Surface mount back box skirt for strobe only Expander Plate SPSEP-BBSW Surface mount back box skirt for speaker strobe Expander Plate Colored Lenses LENS-13 Wall-mount, blue LENS-R Wall-mount, red LENS-G Wall-mount, green LENS-A Wall-mount, amber LENS-BC Ceiling-mount, blue LENS-RC Ceiling-mount, red LENS-GC Ceiling-mount, green LENS-AC Ceiling-mount, amber Decals DECAL-A red letters, used for non-pad-printed wall-mount devices. (10 total decals per box for 5 devices)" DECAL-RC red letters, used for non-pad-printed ceiling- mount devices. (15 total decals per box for 5 devices) DECAL-W white letters, used for non-pad-printed wall-mount devices. (10 total decals per box) for 5 devices* DECAL-WC white letters, used for non-pad-printed ceiling- mount devices. (15 total decals per box for 5 devices) *All Decals include Labels: "AGENT, EVAC, ALERT & FIRE" Retrofit Plates (For use with horn strobe & speaker strobe devices) RFPW 9.5"x 7" white RFP 9.5' x 7' red Mounting Plate MP120K 120 VAC Adapter Mounting Plate Sync Modules MDL3W white, 12/24 volt Sync-Circuit module. MDL3R red, 12/24 volt Sync-Circuit module Trim Rings TR red, wall-mount for use with speaker devices TRC red, ceiling-mount for use with speaker devices TRCW white, ceiling-mount for use with speaker devices TR-HS red, wall-mount for use with horn strobes devices TRW white, wall-mount for use with speaker devices Weatherproof Plates WTPW white, for use with horn, strobes & horn strobe devices WTP red, for use with horn, strobes & horn strobe devices WTP-SPW white, for use with speaker devices WTP-SP red, for use with speaker devices 3825 Ohio Avenue • St. Charles, IL 60174 2015 System Sensor. ...$ Phone: 800-SENSOA2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensorcorn for current product information, including the latest version of this data sheet. SENSOR AVDS4004 • 03/i 5 SYSTEM SENSOR Ilk Audible Visible Accessories System Sensor offers a wide range of Audible Visible (A V) accessories to enable you to meet a variety of application requirements. ••.. Features MP120K Mounting Plate Designed for both indoor and outdoor use Plug-in design eliminates ground faults Power supply that converts 120 VAC to nominal 24 V FWR Compatible with all two-wire SpectrAlert Advance® devices Color Lens Attachments Easily turns any device into a strobe for ECS/MNS events: severe weather, toxic gases, sprinkler activation and more Outdoor rated from —35°F to 151°F Wall- or ceiling-mount lenses available UL 1638 listed WTP Weatherproof Plates Enables flush mounting of outdoor devices to brick, ceramic tile, concrete, and masonry brick Weatherproof NEMA 3R rated For use in both indoor and outdoor applications For use with all K-A series (outdoor) products replacement models Universal mounting plate easily attaches to the weatherproof plate Agency Listings ®Ø MEA USTED approved S4011 7300-1653:0195 562-06-6 S3593 7300-1653:0204 7300-1653:0222 The MP120K Mounting Plate is designed to use 120 VAC to power SpectrAlert Advance horns, strobes, horn strobes, chimes, and chime strobes. Color Lens Attachments install easily on any indoor or outdoor SpectrAlert Advance strobe devices to provide distinctive visual signaling. WTP Series Weatherproof Plates enable installers to flush mount outdoor horns, strobes, horn strobes, speakers, and speaker strobes to a variety of wall surfaces, including brick, ceramic tile, concrete, and masonry brick. These NEMA 3R-rated plates come in red and white to suit aesthetic and functional requirements. Compatible with our outdoor devices, which can be used in indoor and outdoor environments, as required by conditions. They easily attach to the SpectrAlert Advance universal mounting plate. Trim Rings for speakers and speaker strobes allow for additional space within the backbox. Trim ring for horns, strobes, and horn strobes allow 4-wire devices to mount to a single-gang back box. SpectrAlert Advance Outdoor Back Boxes ensure a NEMA 4X weatherproof listing for AV devices. In locations where you have a hard surface to mount to, Surface Mount Back boxes are the best solution. If you have an exposed junction box, the Back Box Skirts offer an attractive solution to mask the junction box exposure. Retrofit Plates cover paint outlines on the wall when replacing legacy SpectrAlert Advance products. SpectrAlert Advance DECALS are for use on our non-pad printed wall- and ceiling-mount devices. Each decal comes with AGENT, EVAC, ALERT, or FIRE label options. The Sync.Circuit Module synchronizes SpectrAlert Advance strobes at 1 Hz and horns and chimes at temporal 3 over a single pair of wires. Patented module technology also allows the silencing of horns or chimes on horn strobe and chime strobe models over a pair of wires. See the Sync.Circuit Datasheet for more information. Specifications 120 VAC mounting plate model MP120K shall be listed to UL 464 for fire protective signaling systems. The mounting plate shall power a two-wire SpectrAlert® Advance horn, strobe, horn strobe, chime or chime strobe from a 120 VAC supply converted to nominal 24 V RNR. For indoor applications, the mounting plate shall be installed in a 4x4x21/8 -inch junction box. For outdoor applications, the mounting plate shall be installed using the proper SpectrAlert Advance outdoor weatherproof back box and outdoor listed notification appliance. Compatibility MP120K may be used with any of the following products at all horn and strobe settings: P2R, P2RH, P2RK, P2RHK, P2W, P2WH, SR, SRH, SRK, SRHK, SW, SWH, PC2R, PC2RH, PC2RK, PC2RHK, PC2W, PC2WH, SCR, SCRH, SCRK, SCRHK, SCW, SCWH, HR, HRK, HW, P2RK-P, P2RHK-P, P2WK-P, P2WHK-P, SRHK-P, SWK-P, SWHK-P, SR-P, SW-P, SRH-P, SWH-P, P2R-P, P2W-P, P2RH-P, P2WH-P, SCW-P, SCRH-P, PC2R-P, PC2W-P, PC2WH-P, SR-SP, P211-SP, CHR, CHW, CHSR, CHSW. Physical/Operating Specifications Standard Operating Temperature —40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Nominal Voltage Regulated 120 VAC Operating Voltage Range 96-132 VAC Current Draw From AC Line 150 mA max. The SpectrAlert Advance weatherproof plate for horns, strobes, and horn strobes shall mount to 4x4x11/4-inch and 2x4x11/2-inch back boxes. The weatherproof plate for speakers and speaker strobes shall mount to 4421/8-inch back boxes. The weatherproof plate may be installed on brick, concrete, ceramic tile, and masonry brick and must be used with System Sensor "K-R" series outdoor replacement models. Outdoor SpectrAlert Advance products shall operate between -40°F and 151°F Speaker Strobe 7.25" Lx 6.26" W x 3.00" D (including speaker and lens) Speaker 7.25" Lx 6.26" W x 1.30" D (including speaker) Horn Strobe 6.90" Lx 5.90" W x 2.80" D (including strobe lens) Horn 6.90" Lx 5.90" W x 1.60" D (including horn) Note: WIP and WTPW are compatible with 4x4x11/4-inch and 2x4x11/2-inch back boxes. (Compatible with outdoor horns, horn strobes and strobes) WTP-SP and WTP-SPW are compatible with 4421/8-inch back boxes. (Compatible with outdoor speakers and speaker strobes) Models Available for Use with the Weatherproof Plates: WTP HRK-R, P2RK-R, P2RHK-R, P4RK-R, SRK-R WTPW P2WK-R, P2WHK-R, SWK-R, SWHK-R WTP-SP SPRK-R, SPSRK-R WTP-SPW SPWK-R, SPSWK-R Note: K-R models ship without the outdoor back box. The weatherproof mounting plates are designed to be used only with K-R replacement models. Specifications The System Sensor SpectrAlert Advance colored lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with plain (no "FIRE print) System Sensor strobe devices. The lens shall mount to any wall- or ceiling-mount strobes and shall be rated from -35°F to 151°F Colored lens attachments may be used with the following System Sensor plain (non-FIRE-printed) indoor or outdoor strobe models: SR-F, SRH-P, SW-F, SWH-P, P2R-P, P2W-P, P2WH-P, P4R-P, P4W-P, P2RK-P, P2RHK-P, SCW-P, PC2R-P, PC2W-P, PC2WH-P, SPSW-P, SPSR-P, SPSWH-P, SPSRH-P, SPSRV-P, SPSCW-P, SPSCWH-P, SPSCN-P, SPSCWVH-P, SPSCWHK-P, SRK-P, SRHK-P, SWK-P, SWHK-P, P2WK-P, P2WHK-P, SPSWK-P, SPSRK-P, SW-CLR-ALERT, SCW-CLR-ALERT, SPSCW-CLRALERT, SEP-SW-F, SEP-SPSW-R Colored Lens Installation Installation to Wall-Mount Strobe Installation to Ceiling-Mount Strobe Candela Rating for UL 1638 Light output of color lenses is measured per UL 1638, on axis, and is not derated." Candela Switch Setting On-Axis Candela Rating (UL1638) -All Colors 15 15 15/75° NA 30 30 75 75 95 95 110 110 115 115 135 135 150 150 177 177 185 185 *15/75 Candela setting not to be used with color lenses Ordering Information (continued) Metal Weatherproof Backboxes MWBBW white, wall-mount, compatible with: SPWK-R, SPWK, SPSWK-R, SPSWK-P, SPSWK, SPSWK-CLR-ALERT MWBB red, wall-mount, compatible with: SPRK-R, SPRK, SPSRHK, SPSRK-P, SPSRK, SPSRK-R MWBBCW white, ceiling-mount, compatible with: SPCWK, SPSCWK,SPCWK-R, SPSCWK-R, SPSCWHK, SPSCWHK-R SA-WBBW white, wall-mount, compatible with: P2WK, P2WHK, P2WHK-P, P2WK-P, SWK, SWK-R, SWK-P, P2WHK-R, P2WK-R, SWHK, SWHK-P, P4WK SA-WBB red, wall-mount, compatible with: P2RK, P2RK-P, P2RK-R, SRK, SRK-P, SRK-R P2RHK, P4RK, P4RHK, SRHK, HRK, P2RHK-R, P2RK-R, HRK-R, P4RHK-R, P4RK-R SA-WBBC red, ceiling-mount, compatible with: SCRK, SCRHK, PC2RK, PC2RHK SA-WBBCW white, ceiling-mount, compatible with: PC2WK, PC2WHK, PC4WK, SCWK, SCWHK Surface Mount Back Box SBBR red, wall-mount, compatible with: HR, CHR, SR, SR-SP, SRH, P2R, P2R-SP, P2RH, P4R, P4RH, CHSR, P2R-P, SR-P, SRH-P SBBW white, wall-mount, compatible with:HW, CHW, SW, SWH, P2W, P2WH, P4W, P4W-P, CHSW, P2W-P, P2WH-P, SW-P, SWH-P, SW-ALERT, SWH-ALERT SBBSPR red, wall-mount, compatible with: SPR, SPRV, SPSR, SPSRH, SPSRV, SPSR-P, SPSRH-P, SPSRV-P SBBSPW white, wall-mount, compatible with: SPW, SPAN, SPSW, SPSWH, SPSWV, SPSW-P, SPSWH-P, SPSW-ALERT, SPSW-CLR-ALERT SBBCR red, ceiling-mount compatible with: SCR, SCRH, PC2R, PC2RH, PC4R, PC4RH, SPCR, SPCRV, SPSCR, SPSCRH, SPSCRV, SPSCRVH, PC2R-P SBBCW white, ceiling-mount, compatible with: SCW, SCWH, PC2W, PC2W-SP, PC2WH, PC4W, SPCW, SPCWV, SPSCW, SPSCWH, SPSCWV, SPSCWVH, PC2W-P, PC2WH-P, SCW-P, SPSCW-P, SPSCWH-P, SPSCWHK-P, SPSCVVV-P, SPSCWVH-P, SPSCW-CLR-ALERT, SCW-CLR-ALERT Back Box Skirts BBS-SP201W Surface-mount back-box skirt for the PF24V (ExitPointTM Directional Sounder with Voice Messaging) SEP-BBSW Surface mount back box skirt for strobe only Expander Plate SPSEP-BBSW Surface mount back box skirt for speaker strobe Expander Plate Colored Lenses LENS-13 Wall-mount, blue LENS-R Wall-mount, red LENS-G Wall-mount, green LENS-A Wall-mount, amber LENS-BC Ceiling-mount, blue LENS-RC Ceiling-mount, red LENS-GC Ceiling-mount, green LENS-AC Ceiling-mount, amber Decals DECAL-R red letters, used for non-pad-printed wall-mount devices. (10 total decals per box for 5 devices)* DECAL-RC red letters, used for non-pad-printed ceiling- mount devices. (15 total decals per box for 5 devices) DECAL-W white letters, used for non-pad-printed wall-mount devices. (10 total decals per box) for 5 devices* DECAL-WC white letters, used for non-pad-printed ceiling- mount devices. (15 total decals per box for 5 devices) *All Decals include Labels: "AGENT, EVAC, ALERT & FIRE" Retrofit Plates (For use with horn strobe & speaker strobe devices) RFPW 9.5' x 7 white RFP 9.5' x T red Mounting Plate MP120K 120 VAC Adapter Mounting Plate Sync Modules MDL3W white, 12/24 volt Sync-Circuit module. MDL3R red, 12/24 volt Sync-Circuit module Trim Rings TR red, wall-mount for use with speaker devices TRC red, ceiling-mount for use with speaker devices TRCW white, ceiling-mount for use with speaker devices TR-HS red, wall-mount for use with horn strobes devices TRW white, wall-mount for use with speaker devices Weatherproof Plates WTPW white, for use with horn, strobes & horn strobe devices WTP red, for use with horn, strobes & horn strobe devices W1P-SPW white, for use with speaker devices WrP-SP red, for use with speaker devices 3825 Ohio Avenue • St. Charles, IL 60174 System Sensor Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject tochange without notice. Visit systemsensor.com SENSOR www.systemsensor.com for current product information, including the latest ve,sion of this data Sheet. AVDS4004 • 03/15 I FORGED STEEL FITTINGS Materials The steel for Anvil Forged Carbon Steel Fittings consists of forging, bars, seamless pipe or tubes which conform to the requirements for melting process, chemical composition and mechanical properties of ASTM A105. Design Basis ASME B16.11 - Forged fittings, socket-weld and threaded Dimensions ASME B16.11, unless otherwise noted Threads ANSI/ASME 131.20.1 NPT Threads Forged Steel Fittings In accordance with ASME standard B16.11 - "Forged Fittings, Socket-Welding and Threaded" this table shows the schedule of pipe corresponding to each class of fitting for rating purposes. PRESSURE RATINGS Class Schedule N.P.T. 2000 80 - 3000 160 80 6000 XXS/XXH 160 ASME B16.11 provides that the maximum allowable pressure of a fitting be computed in accordance with the applicable piping code or regulation for straight seamless pipe or for material of equivalent composition and mechanical properties to the fitting. Any corrosion or mechanical allowances and any reduction in allowable stress due to temperature or other service conditions must be applied to the pipe and fitting alike. Reducing Fittings Reducing elbows, tees and crosses are available in both threaded and socket-welding. On reducing tees and crosses give the size of the largest run opening; then give the opposite opening. On a tee give the branch size last. On a cross give the largest side outlet third and the opposite opening last. 9 Side Branch ,ILII:i:II Outlet \ 1½x3/.x11,4 1½X 3/4X11/4 x½ TEE CROSS rl Side Branch 4Ii_'k LIIi_ Outlet \ 13 8x 19x32mm J138x19x32x13mm TEE CROSS Standards and Specifications Dimensions Material Thread Pressure Rating FORGED STEEL THREADED FITTINGS Class 2000,3000,6000 I_ ASME Ell 6.11.I_ASTM A105, ASTM Al 82, ASTM A350 I_ASMEB1 .20.1+I_ASME1316.1 1. an American National standard (ANSI), + ASME 131 .20.1 was ANSI B2.1 90 www.anvi1int1.com ________ I II Forged Steel Fittings Class 2000 Threaded FIGURE 2101 90 Elbows Size A H Unit Weight H NPS ON in mm in mm lbs kg 1/4 8 0.81 21 0.88 22 0.18 0.08 ½ 10 0.97 25 1.00 25 0.28 0.13 1/2 15 1.12 28 1.31 33 0.55 0.25 ½ 20 1.31 33 1.50 38 0.72 0.33 1 25 1.50 38 1.81 46 1.22 0.55 11/4 32 1.75 44 2.19 56 1.65 0.75 11/2 40 2.00 51 2.44 62 2.12 0.96 2 50 2.38 60 2.97 75 3.78 1.71 21/2 65 3.00 76 3.62 92 6.50 2.95 3 80 3.38 86 4.31 109 11.10 5.03 4 100 4.19 106 5.75 146 22.30 10.11 FIGURE 2102 450 Elbows Size C H Unit Weight 1I NPS ON in mm in mm lbs kg 1/4 8 0.69 17 0.88 22 0.16 0.07 ½ 10 0.75 19 1.00 25 0.25 0.11 1/2 15 0.88 22 1.31 33 0.48 0.22 3/4 20 1.00 25 1.50 38 0.57 0.26 1 25 1.12 28 1.81 46 0.88 0.40 11/4 32 1.31 33 2.19 56 1.32 0.60 11/2 40 1.38 35 2.44 62 1.62 0.73 2 50 1.69 43 2.97 75 2.83 1.28 21/2 65 2.06 52 3.62 92 7.70 3.49 3 80 2.50 64 4.31 109 12.00 5.44 PF-6.1 3 FORGED STEEL MI Forged Steel Fittings Class 2000 Threaded FIGURE 2103 Tees Size A H Unit Weight 0 H I I..- A-1 NPS ON in mm in mm lbs kg 1/4 8 0.81 21 0.88 22 0.25 0.11 10 0.97 25 1.00 25 0.37 0.17 1/2 15 1.12 28 1.31 33 0.62 0.28 34 20 1.31 33 1.50 38 0.43 0.20 1 25 1.50 38 1.81 46 1.33 0.60 11/4 32 1.75 44 2.19 56 2.10 0.95 11/2 40 2.00 51 2.44 62 2.80 1.27 2 50 2.38 60 2.97 75 4.50 2.04 2½ 65 3.00 76 3.62 92 9.10 4.13 3 80 3.38 86 4.31 109 13.50 6.12 4 100 4.19 106 5.75 146 32.00 14.51 FIGURE 2104 Crosses Size A H Unit Weight NPS ON in mm in mm lbs kg 1/4 8 0.81 21 0.88 22 0.50 0.23 ¼ 10 0.97 25 1.00 25 0.40 0.18 ½ 15 1.12 28 1.31 33 0.85 0.39 34 20 1.31 33 1.50 38 1.10 0.50 1 25 1.50 38 1.81 46 1.70 0.77 11/4 32 1.75 44 2.19 56 2.40 1.09 11/2 40 2.00 51 2.44 62 3.20 1.45 2 50 2.38 60 2.97 75 5.20 2.36 21/2 65 3.00 76 3.62 92 16.50 7.48 3 80 3.38 86 4.31 109 20.00 9.07 PF-6.1 3 0 a, .0 cc a, H II Forged Steel Fittings Class 3000 Threaded FIGURE 2111 900 Elbows Size A H Unit Weight A-j I NPS ON in mm in mm lbs kg 1/5 6 0.81 21 0.88 22 0.23 0.10 1/4 8 0.97 25 1.00 25 0.35 0.16 % 10 1.12 28 1.31 33 0.66 0.30 1/2 15 1.31 33 1.50 38 0.93 0.42 20 1.50 38 1.81 46 1.48 0.67 1 25 1.75 44 2.19 56 2.30 1.04 11/4 32 2.00 51 2.44 62 .68 1.22 - 11/2 40 2.38 60 2.97 75 .30 2.40 - 2 50 2.50 64 3.31 84 ..85 2.65 21/2 65 3.25 83 4.00 102 10.00 4.54 3 80 3.75 95 4.75 121 17.20 7.80 4 100 4.50 114 6.00 152 1 29.30 13.29 FIGURE 2112 450 Elbows Size C H Unit Weight NPS ON in mm in mm lbs kg 1/8 6 0.69 17 0.88 22 0.18 0.08 1/4 8 0.75 19 1.00 25 0.25 0.11 10 0.88 22 1.31 33 0.53 0.24 1/2 15 1.00 25 1.50 38 0.78 0.35 % 20 1.12 28 1.81 46 1.20 0.54 1 25 1.31 33 2.19 56 1.90 0.86 1¼ 32 1.38 35 2.44 62 2.30 1.04 11/2 40 1.69 43 2.97 75 4.16 1.89 2 50 1.72 44 3.31 84 5.12 2.32 21/2 65 2.06 52 4.00 102 7.70 3.49 3 80 2.50 64 4.75 121 12.00 5.44 4 100 3.12 79 6.00 152 19.70 8.93 FIGURE 2114 Tees Size A H Unit Weight T 1 I.- A-+-1 0 NPS ON in mm in mm lbs kg 1/8 6 0.81 21 0.88 22 0.31 0.14 1/4 8 0.97 25 1.00 25 0.42 0.19 10 1.12 28 1.31 33 0.93 0.42 ½ 15 1.31 33 1.50 38 1.20 0.54 % 20 38 _1.50 1.81 46 1.84 0.83 25 1.75 44 2.19 56 3.05 1.38 11/4 32 2.00 51 2.44 62 3.62 1.64 11/2 40 2.38 60 2.97 75 6.65 3.02 2 50 2.50 64 3.31 84 7.15 3.24 21/2 65 3.25 83 4.00 102 13.70 6.21 3 80 3.75 95 4.75 121 21.00 9.52 4 100 4.50 114 6.00 152 38.00 17.23 www.anvilint1.com 93 I I FORGED STEEL FITTINGS 1117 Forged Steel Fittings Class 3000 Threaded FIGURE 2115 Crosses Size A H Unit Weight ~IAA-.2 NPS ON in mm in mm lbs kg 1/8 6 0.81 21 0.88 22 - - 1/4 8 0.97 25 1.00 25 - - 10 1.12 28 1.31 33 - - 1/2 15 1.31 33 1.50 38 1.40 0.63 % 20 1.50 38 1.81 46 2.10 0.95 1 25 1.75 44 2.19 56 3.50 1.59 11/4 32 2.00 51 2.44 62 4.30 1.95 11/2 40 2.38 60 2.97 75 8.20 3.72 50 2.50 64 3.31 84 8.40 3.81 21/2 65 3.25 83 4.00 102 17.10 7.76 3 80 3.75 95 4.75 121 20.00 9.07 4 100 4.50 114 6.00 152 32.00 14.51 FIGURE 2113 90 Street Elbows Size A C H Unit Weight *- fob 1-H'-1 NPS ON in mm in mm in mm lbs kg 1/8 6 0.75 19 1.00 25 0.75 19 - - 1/4 8 0.88 22 1.25 32 1.00 25 0.23 0.10 % 10 1.00 25 1.50 38 1.25 32 0.38 0.17 ½ 15 1.12 28 1.62 41 1.50 38 0.53 0.24 ~ 20 1.38 35 1.88 48 1.75 44 0.88 0.40 1 25 1.75 44 2.25 57 2.00 51 1.40 0.63 11/4 32 2.00 51 2.62 66 2.44 62 2.40 1.09 11/2 40 2.12 54 2.81 71 2.75 70 2.90 1.32 2 50 2.50 64 3.31 84 3.31 84 5.00 2.27 FIGURE 2116 Size B K I Unit Weight Laterals NPS ON in mm in mm in mm lbs kg 1/2 15 1.56 39.62 2.56 65.02 3.56 90.42 1.75 0.79 % 20 1.84 46.74 3.00 76.20 4.13 104.90 2.75 1.24 1 25 2.22 56.39 3.50 88.90 4.81 122.17 4.63 2.10 11/4 32 2.50 63.50 3.94 100.08 5.38 136.65 5.50 2.48 1 L 11/2 40 3.03 79.96 4.75 120.65 6.44 163.58 10.81 4.91 2 50 3.34 84.84 5.00 127.00 6.63 168.40 11.50 5.23 PF-11.13 I [1 Forged Steel Fittings Class 3000 Threaded FIGURE 2117 Size Couplings D W Unit Weight NPS ON in mm in mm lbs kg 1/s 6 0.62 16 1.25 32 0.14 0.06 14 8 0.75 19 1.38 35 0.10 0.05 % 10 0.88 22 1.50 38 0.13 0.06 ½ 15 1.12 28 1.88 48 0.28 0.13 20 1.38 35 2.00 51 0.44 0.20 1 25 1.75 44 2.38 60 1.08 0.49 114 32 2.25 57 2.62 67 1.68 0.76 _Jff I w 11/2 40 2.50 64 3.12 79 2.17 0.98 2 50 3.00 76 3.38 86 3.20 1.45 21/2 65 3.62 92 3.62 92 4.70 2.13 3 80 4.25 108 4.25 108 6.80 3.08 4 100 5.50 140 4.75 121 12.30 5.58 FIGURE 2119 Half Couplings Size 0 W12 Unit Weight ______ k W,2-'I NPS ON in mm in mm lbs kg 1/8 6 0.62 16 0.63 16 0.05 0.02 1/4 8 0.75 19 0.69 18 0.04 0.02 % 10 0.88 22 0.75 19 0.06 0.03 1/2 15 1.12 28 0.94 24 0.12 0.05 3/4 20 1.38 35 1.00 26 0.21 0.10 1 25 1.75 44 1.19 30 0.43 0.20 11/4 32 2.25 57 1.31 34 0.76 0.34 11/2 40 2.50 64 1.56 40 1.14 0.52 2 50 3.00 76 1.69 43 1.50 0.68 21/2 65 3.62 92 1.81 46 2.40 1.09 3 80 4.25 108 2.13 54 3.25 1.47 4 100 5.50 140 2.38 61 6.25 2.83 PF-6.1 3 I FORGED STEEL FITTINGS Forged Steel Fittings Class 3000 Threaded FIGURE 2118 Size Reducing Couplings D W Unit Weight J1flAJfl -ffl1ffl1f7 [ll111J11JJ/LjJ I w I NPS ON NPS ON in mm in mm lbs kg 1/4 8 1/8 6 0.75 19 1.38 35 0.10 0.05 10 1/8 6 0.88 22 1.50 38 0.15 0.07 1/2 15 '/8 6 1.12 28 1.88 48 0.35 0.16 % 20 '/8 6 1.38 35 2.00 51 0.52 0.24 1 25 '/8 6 1.75 44 2.38 60 1.10 0.50 11/4 32 ¼ 8 2.25 57 2.62 67 2.08 0.94 11/2 40 '/4 8 2.50 64 3.12 79 2.93 1.33 2 50 '/4 8 3.00 76 3.38 86 4.40 2.00 21/2 65 ¼ 20 3.62 92 3.62 92 7.50 3.40 3 80 3/4 20 4.25 108 4.25 108 11.00 4.99 4 100 11/2 40 5.50 140 4.75 121 20.50 9.30 FIGURE 2120 Size Pipe Caps D P Unit Weight -D 0 k P NPS ON in mm in mm lbs kg 1/8 6 0.62 16 0.75 19 0.07 0.03 1/4 8 0.75 19 1.00 25 0.08 0.04 10 0.88 22 1.00 25 0.11 0.05 1/2 15 1.12 28 1.25 32 0.23 0.10 % 20 1.38 35 1.44 37 0.40 0.18 1 25 1.75 44 1.62 41 0.79 0.36 11/4 32 2.25 57 1.75 44 1.21 0.55 11/2 40 2.50 64 1.75 44 1.75 0.79 2 50 3.00 76 1.88 48 2.46 1.12 21/2 65 3.62 92 2.38 60 4.37 1.98 3 80 4.25 108 2.56 65 6.50 2.95 4 100 5.50 140 2.69 68 11.30 5.12 PF-6.1 3 / Fire Protection FPS-13R J)TOLCO - ! k L j. $ - Fire pTotec-~'t'lo-T!11---.Val_gr.Luba5~,r solutions