HomeMy WebLinkAbout7190 AVENIDA ENCINAS; ; AS050250; PermitJob Address:
Permit Type:
Parcel No:
7190 AVENIDA
ENCINAS
SPRINK
Lot #: 0
Reference No.:
PC #:
City of Carlsbad
Sprinkler Permit
Permit No: AS050250
Status: PENDING
Applied 12/8/2005
Approved:
Issued:
Inspector:
Project Title: NORTH ISLAND CREDIT FIRE SPRINKLER PLAN CHECK &
INSPECTIONS
Applicant: Owner:
WESTERN FIRE PROTECTION
12232 THATCHER CT
P0 WAY CA
858-513-4949
Fees ($) Add'I Fees ($) Total ($) Balance ($)
115 0 115 0
City of Carlsbad
07-28-2005 Fire Department Permit Permit No: FAD05023
Job Address: 7190 AVENIDA ENCINAS CBAD
Permit Type: FADD Subtype: HYD Status:6"lann f7j%
Parcel No: Lot #: 0 Applied:
Issued:19/ WOO
Fire Dept Ref#: Building Permit#: Entered By: BSM
Location
Project Title. POINSETTIA VILLAGE
Descripp: \ HYDRANT FLOW TEST ON 8/4/05
Contrctor:
ALTERNATIVE F RE Phone: 619-280-8295
3 SITY AV
Fax:
SAN DIEGO CA 92104
Total Fees $65.00 Total Payments To Date $0.00
Permit Fee $65.00
Additional Permit Fee $0.00
Re-Inspection Fee 0 $0.00
Other $0.00
Additional Fees $0.00
TOTAL PERMIT FEES $65.00
404 08/12/05 0002 Oi 02
COP 6500
NOTICE: Please take NOTICE that approval of your project includes the"Imposition" of fees, dedications, reservations, or other exactions hereafter col
l
e
c
t
i
v
e
l
y
referred to as fees/exactions. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you
p
r
o
t
e
s
t
t
h
e
m
,
y
o
u
m
u
s
t
follow the pretest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manage
r
f
o
r
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
FIRE PREVENTION DIVISION
1635 FARADAY AVENUE, CARLSBAD, CA 920087314
I7fl\ fl')..Ar
A.11em:ative Fire
CoMPLEI YSMS * fLc;N. FABRICATION & FNTALLATR) w\' 74. 1..AKr LINCflE CA 9 23?
IRON0 (909) 245./TIn
( C-(C) I
FL(i)\VTE ST
DATE -Jo-c
FLOW TEST AT .Pocii •'UA
STATICREADQ_ ...L_..........
RESIDUAL READING
0.
PIT-0 READING
........--....--
WITNES s:ED By. •1 UJ.
COMPANY
In
:(
QUICK RESPONSE
RECESSED
HORIZONTAL SIDEWALL
4.
QUICK RESPONSE
A UTOMA TIC SPRINERS
GL SERIES
RECESSED PENDENT
RECESSED HORIZONTAL SIDE WALL
DESCRIPTION AND OPERATION
The Globe Quick Response GL Series Sprinkler is a low profile yet
durable design which utilizes a 3mm frangible' glass ampule as the / thermosensitive element. This provides sprinkler operation approxi / ( !
mately six times faster than ordinary sprinklers. While the Quick .
Response Sprinkler provides an aesthetically pleasing appearance, it can
be installed wherever standard spray sprinklers are specified but offers . ..'./
the additional feature of greatly increased safety to life. Quick Response e
Sprinklers should be used advisedly and under the direction of approving
authorities having jurisdiction.
The heart of Globe's GL Series sprinkler proven actuating assembly QUICK RESPONSE
is a hermetically sealed frangible glass ampule that contains a precisely RECESSED PENDEN1 measured amount of fluid. When heat is absorbed, the liquid within the
,bulb- expands increasing the internal pressure.; At the prescribed
temperature the internal pressure within the ampule exceeds the
strength of the glass causing the glass to shatter. This results in water
discharge Which is distributed in an approved pattern depending upon the
deflector style used. -
TECHNICAL DATA
See reverse side for Approvals and Specifications.
Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C),
200°F (93°C), 286°F (141°C).
Water Working Pressure Rating - 175 psi (12 Bars).
Factory tested hydrostatically to 500 psi (34 Bars).
Maximum low temperature glass bulb rating is -67°F (-55°C).
Frame - bronze - Deflector - brass Screw - brass. .
Bulb seat - copper Spring - nickel alloy Seal - teflon
Bulb - glass with alcohol based solution, 3mm size.
Escutcheon Assembly - steel
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
CLASSIFICATION AVAILABLE SPRINKLER BULB N.F.P.A. MAXIMUM
TEMPERATURES COLOR CEILING TEMPERATURE
ORDINARY 35 FuSS F 57 C/68 C ORANGE/RED 1007 38'C
INTERMEDIATE 175'F/200'F 79'C/93'C YELLOW/GREEN 150 F 66'C
HIGH 286'F 141 C BLUE 225 F 107'C
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 5 1 7-846-4583 • FAX 5 17-846-923 I
NOVEMBER 2000 A-7 . BULLETINGL28OI
oA. QUICK RESPONSE
A UTOMA TIC SPRINKLERS
G T'S EkiES
RECESSED PENDENT
RECESSED HORIZONTAL SIDEWALL
SPECIFICATIONS
NOMINAL "K" FACTOR THREAD SIZE *LENGTH FINISHES
2.8 (39 metric) 1/2' NPT 2 114' (5.7 cm) Factory Bronze
4.2 (59 metric) /2" NPT 2 /4" (5.7 cm) 'Satin Chrome
Bright Chrome
5.6 (80 metric) 1/2" NPT 2 114" (5.7 cm) White Polyester*
(1 II metric) '' 1/2" NPT 21/4" (5.7cm) Black PoIyster+"
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) '4°11-ead Coated
NOTE: METRIC CONVERSIONS ARE APPROXIMATE. *HORIZONTAL SIDEWALL IS 2 9/16'.
FINISHES AVAILABLE ON SPECIAL ORDER.
+AVAILABLE AS UL LISTED CORROSION RESISTANT
WHEN SPECIFIED ON ORDER.
APPROVALS
STYLE K
FACTOR
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C U.L.MEA U.L.CANADIAN FM L.P.C..Y.C.-D.O.B.
I0I-92-E
2.8 X X X X X X X --- --- x
14.2 'X'"X X X x
PENDENT 5.6 X X X X X X X X X X
RECESSED t
7,8* X X X X X X X X --- X
8.1 X X X X X X X X X X
2.8 X X X X X X X --- --- X
HORIZONTAL SIDEWALL 4.2 X X X X X X X --- --- x
'RECESSED § 5.6 ''x' x x x '" x x x --- -.- ",. x
8.1 X X X X X X X --- --- X
§ HORIZONTAL SIDEWALL U.L. AND C-U.L. LISTED FOR DEFLECTOR 4" TO IT, BELOW THE CEILING.
tLISTEDD FOR ALL HAZARDS. CROSS SECTIONS * 7/32" X /2"
I
ORDERING INFORMATION
SPECIFY
Quantity Model Number Style
Orifice Thread Sizes Temperature
Finishes desired
Quantity - Recessed Wrenches - P/N 325391 (112"); P/N
325401, Rev. F (L.a.)
GLOBE® PRODUCT WARRANTY
Globe agrees to repair or replace any off its own manufac-
tured products found to be defective in ma:eerial or workman-
ship for a period of one year from date ci shipment.
For specific details of our warranty please refer to Price
List Terms and Conditions of Sale (Our Price List).
- 2 15/16" DI*-
2" OIA. SIN,
1 29/32" 0*. X S0s,C2''N., Cu
REWCER RETAINER - (
qat MIN.
ki ffil SIN OO**S
1 3/9 MAX
—j
:--I--L
PENDENT HORIZONTAL
SIDEWALL
LOBE®
FIRE .SPRINKLER
CORPORATION
NOVEMBER 2000
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
517-846-4583 FAX 517-846-9231
1-800-248-0278 www.gkDbesprinkler.com
PRINTED U.S.A. BULLETIN GL280