Loading...
HomeMy WebLinkAbout2544 CAMPBELL PL; ; FPC2020-0028; PermitPERMIT REPORT aity of Carlsbad Print Date: 05/19/2022 Job Address: 2544 CAMPBELL PL, CARLSBAD, CA 92009-1768 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel U: 2132611800 Track U: Valuation: $0.00 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Permit No: FPC2020-0028 Status: Closed - Finaled Applied: 02/18/2020 Issued: 02/27/2020 Finaled Close Out: 07/28/2020 Final Inspection: INSPECTOR: Maldonado, Adalmira Salcedo, Felix Project Title: Description: CAMPBELL PL COMMON AREA-ALARM TI (5 DEVICES) NEW NOTIFICATION DEVICES TO FITNESS AREA/RESTROOMS/LOCKERS. REMOVE/REINSTALL EX. DEVICES IN REMODELED CORRIDORS & ELEVATOR LOBBY. Applicant: DIALCOM SYSTEMS GROUP P0 BOX 462166 ESCONDIDO, CA 92046-2166 (760) 520-5044 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 1 I www.carlsbadca.gov PJ HI Systems Group, Inc. FIRE ALARM SUBMITTTAL FOR Campbell Place Common Area Remodel 2544 Campbell Place Carlsbad, CA 92009 Submitted by: DIALCOM SYSTEMS GROUP, INC. P.O. Box 462166 Escondido, CA 92046 /i LkE7©uiii Systems Group, Inc. Phone 760-520-5044 * Fax 760-839-5892 *C40 703343 * ACO 7107 PROJECT INFORMATION SHEET INSTALLING CONTRACTOR: CONTRACTORS LICENSE: DIALCOM SYSTEMS GROUP 1541 SIMPSON WAY ESCONDIDO, CA 92029 C-10 703343 Jeff DuB eau Cell: 760-644-4548 j eff(dialcomsystemsgroup.net Campbell Place Common Area Remodel 2544 Campbell Place Carlsbad, CA 92009 PROJECT MANAGER: CONTACT INFO: PROJECT NAME: PROJECT ADDRESS: SCOPE OF WORK: Tenant improvement in an existing building with an existing fire alarm system. Adding additional NAC devices to the remodeled space and removing, reinstalling/relocating the existing NAC devices as indicated on the plans. Kidde Catalog t> Strobes, Horns, Bells, Chimes fUnite u I chnoIoi Technology that saves lives Field Configurable.>~~L~ERr `- Ceiling Strobes Genesis Series 1 , X @ FICE 7125-1483: 01 61 MEA One or more patents pending. Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, Kidde Genesis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FuliLight technology. FuilLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1971 and ULC-S526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullUght strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - ULJULC listed for ceiling or wall use Page 1 of 4 DATA SHEET K85001-0557 Not to be used for installation purposes. issue 1 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/fl (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 6.8dia. (173 mm) - --. 1' 1.o (25 mm) 0.60(15 mm) Light output (effective Cd) Percent of UL rating versus angle Percentage of rated output - - Angle — Hodzontat and vergcat outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output Candela switch (see ordering information). The output / ,_— setting is changed by simply opening the , / device and sliding the switch to the desired setting. The strobe does not have to be removed to change the output setting. 7 The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. go, To listed 1111 To next r T appliance, fire alarm cn co I end-of-line H control or retum to panel I control equipment Page 2of 4 DATA SHEET K85001-0557 Not to be used for installation purposes. Issue 1 Light output setting, high output models "95" or "D" I "115" or "C" I "150" or "B" I "177" or "A" RMS RMS I RMS RMS 330 392 502 565 432 518 643 693 "95" or "0" Light output setting, high output models "115" or "C" "150" or "B" "177" or "A" RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. UL Light output setting, standard models 1 "15" or "D" "30" or "C" "75" or "B" 095" or "A" Rating F RMS RMS RMS RMS 16 Vdc 109 151 281 318 16Vfwr 131 194 379 437 Typical Light output setting, standard models "15" WOW "30" or "C" 1975" or "B" "95" or "A" Current RMS RMS RMS RMS 16 Vdc 94 140 273 325 20 Vdc 74 108 205 244 24 Vdc 63 90 168 194 33 Vdc 48 70 124 139 16 VW 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Current values are shown in mA. Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear). M Mounting Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating environment Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1 638 and UL1 971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA. FM pending. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Strobe operating voltage GC-VM series strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR. GC-VM series strobes: one flash per second synchronized with optional EG1 M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. Synchronization Sources FACPs: VM and VS Series life safety systems, FX Series fire alarm control panels. Moduels: GSA-CC 5, GSA-MCC1 5, SlGA-CC2A, GSA-MCC2A, EG1M-RM. Power supplies: MIRBPS6A, MIRBPS1OA, APS6A, APS10A. Page 3 of 4 DATA SHEET K85001 -0557 Not to be used for installation purposes. Issue 1 Ordering Information ;:::7 Kdde Light output switch settings for UL 1971 listed models are selectable by numeric candela value. N = ECS/MNS appliances are selectable by A, B, C, or D designations. Technology that saves lives Model I Housing I Marking I Lens I Strobe Ship Wt. Contact us... Life safety Appliances (c/w running man icon screen printed on housing) Email: kidde.fire@fs.utc.com EGC-VM - Web: Kidde.com/EnoineeredSvstems to -VM EGCFR-VM Kidde is a UTC brand. EGC-VMH 1016 Corporate Park Drive Mebane, NC 27302 EGCF-VMH White None Clear Selectable 15, 30, 75, or 95 Cd 1.8 lb. (0.82 kg.) White Red "FlRE". FIRE" White None Selectable high output 95, 115, 150, or 177 Cd White "FIRE" © 2016 United Technologies Corporation. All rights reserved. ECS/MNS Appliances (no running man icon on housing) GCWA-VMA White "Alert" Amber Selectable A, B, C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear GCWNVMA None ______ Amber GCWN-"/MC Clear GCWA-VMHA "Alert " Amber Selectable high output A, B, C or D Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMHC Units with red, blue or green lenses are available as a special order. Contact customer service for details. Th XLE (RT Page 4 of 4 DATA SHEET K85001-0557 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1501:0150 Page 1 of I CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE; EDWARD SIGNAL8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models EGC-VM, EGCF-VM, *EGCFR..VM EGC-VMH, and EGCF-VMH multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with Edwards Systems Technology's Model Gi M-RM (CSFM Listing No. 7300-1591:201) sync module, which may employ Model SIGA-CC1S (CSFM Listing No. 7300-1591:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 V dc1vFWR GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL; Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7125-1657:0219 *Rev. 05-15-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division MEA CE Patented CS405 Series Edwards Signaling Catalog 11> Strobes, Horns, Bells, Chimes wards Signaling Harsh Environment Strobes CS405-7A, -8A Overview CS405 Series strobes are specially designed for use with compat- ible life safety communication and control equipment to alert the hearing impaired of a life safety event. Strobes are available with 15/75 cd and 110 cd effective flash intensity. They are fully com- patible with Genesis signals. 0S405 Series strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a separately-installed EG1 M Signal Master, or E-NAC Synchronization Module, or when powered by suitably enabled booster power supplies and control panels. The flash from CS405 Series strobes can be noticed from almost any position in the room, corridor, or large open space. 0S405 Series strobes are UL 1971 listed with both wall and ceiling cd intensity ratings (see Specifications). This is useful in areas where the Authority Having Jurisdiction (AHJ) permits ceiling-mount strobes. 0S405 Series strobes are designed for 16 to 33 Vdc operation and must be connected to signal circuits that output a constant (not pulsed) voltage. A diode is used to allow full signal circuit supervision and polarized connections are made to terminals that accept up to #12 AWG (2.5mm2) wire. The strobe front plate is of steel construction finished with durable baked epoxy polyester powder-coat paint. Standard Features UL 1971-listed synchronizing strobe Integrity strobes synchronize to the latest UL 1971 require- ments when used with a synchronization source. Genesis-compatible PJl Genesis and Integrity strobes on the same circuit meet UL 1971 synchronization requirements when used with an external control module. Approved for public and private mode applications UL 1971-listed as signaling devices for the hearing impaired and UL 1638-listed as protective visual signaling appliances. Rugged red or white steel front plate Ideal for outdoor or harsh environments. Rated for wall or ceiling installation Field changeable field markings Lens language or standard 'FIRE" marking is easily changed with optional LKW and LKC series lens kits. Fits 4-inch square flush box Ideal for retrofit and renovation projects. UL/ULC rated outdoor option Page lof4 DATA SHEET S850010305 Not to be used for installation purposes. Issue 8 Application NOTE: The installation of visible signals are subject to national and local standards, codes, and ordinances. Consult your Authority Having Jurisdiction for device installation requirements, application standards, and minimum performance specifications. Edwards strobes are UL 1971-listed for use indoors as wall-mounted public-mode notification appliances for the hearing impaired. Prevail- ing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. As part of the Enhanced Integrity line of products, CS405 Se- ries strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important because a small portion of the population have a condition which may cause them to become disoriented from multiple random flashes of light. Integrity strobes minimize this risk. Integrity strobes are fully compatible with Edwards Genesis sig- nals. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. Edwards recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Operating Current (RMS) UL 15/75 cd 110 cd Rating 16 Vdc 150 329 16Vfwr 210 420 Typical 15/75 cd 110 cd Current 24 Vdc I 90 I 180 24Vfwr 128 260 Vdc: Volts direct current, regulated and filtered vfwr: Volts full wave rectified Current Draw Notes and Comments 1 Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement meth- ods and instruments used. Edwards recommends using the Typical currant for system design including NAC and Power Supply loading and voltage drop calculations. Use the 16 Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the 16 Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current determines the heating affect and therefore, the trip and hold threshold for those devices. Typical Wiring - 24 Vdc Installation and Mounting All models fit to a standard flush mounted, North American four inch electrical box, 1-1/2 inch (38 mm) deep minimum. Optional Edwards weatherproof, surface mount boxes are available. The strobes must be connected to signal circuits which output a constant (not pulsed) voltage. Edwards recommends that these strobes always be installed in accordance with the latest recog- nized edition of national and local fire alarm codes. 0.25" - (6 mm) \. FIRE! HRH SIDE VIEW, LI_-' CEILING MOUNTED . Changeable Lens Marking, liON or LKC Series. (48 mm) (14U mm Countersunk Philip ma head screws are provided to secure unit onto electri- cal box. Two Plastic Caps are pro- 0 sided for indoor mounting. 1+1 ULJULC Lists Place on end.of- 24V dc line resistor on the Firs Alarm last device (reslsto Control Porn supplied with (signal circul control panel) Page 2of4 DATA SHEET S850010305 Not to be used for installation purposes. Issue 8 Light Distribution 15 cd (-5A) Series Strobes 30 cd (-3A) Series Strobes 110 cd (-8A) Series Strobes Horizortal Output Horizonal Output Horizortal Output 4'mmim,,~ I" ilia -'MI .ØllI*1Dr IS I'ARN11411N, 60 40 20 Cd 20 40 60 VerlicEl Output -9O 150 n-' 7 -60 4?LP>-45 100 -30 1 50 5 CD cd ____ 50 Jj/15 100 30 . Li,60 "'' c 5 [=Average ULmIn Vertical 90 90 90" Horizontal Vertical Output Specifications Catalog Number CS405-7A CS405-8A, CS405-8A UL 1638/ULC Sf26 15/75c6 110cd Rated _Strobe _Output UL 1971 Rated Strobe 15cd wail 110cd wall Output 1 f.cd ceiling 60cd ceiling Strobe Flash Rat.° Synchronzed at one flash Der second. External control module necessary to meet UL 1971 synchronization requirements of 10 milliseconds over a two-hour period. Synchronization Sources EG1 M-RM, EBPS6, EBPSIO, E-N?C, E-FSC, E-FSA Strobe Operating Volts Continuous 16 to 33 Vdc or 16 to 33 Vfwr INDOOR: 30° C @ 85% RH; 32 - 123° F (0 - 49° C) ambient :enperature. Operating Environment OUTDOOR (CS models on y): 30° C @ 93% RH; -40-150° F (-43-66° C) ambient temp TA' (17.7cd @ -35° C per UL @ -400 C per ULC) and; '8A' (70.7cd @ -35°C per UL © -40°C per LLC) models only Markings Lens Markin Supplied wcth LK'iN-1 FIRE" red leters, vertical both sides ('Itfa Mount) - see LKtV and LKC series for ceiling style and optional markings Wire Connectione Terminals - polarized input, #12 AWO (2.5mm2) max wire size Flash Tube Enclosure Clear LEX.AN Strobe Plate, Finish CRS steel - 51/2 in (140mm square, red or white baked epoxy oolyester powder-coat finish Mounting INDOOR: North American L in square electrical box; OUTDOOR 449 series weatherproo surface box Agency Listings UL 1971 JL 1638, ULC S526, CE, FM, CSFM, MEA (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule) Page 3ot4 DATA SHEET S850010305 Not to be used for installation purposes. Issue 8 Ordering Information Catalog Number Description Ship Wt lb (kol Outdoor Listed Strobes - CS405-7A-T Strobe, 15/75, Outdoor, Red 1(0.4) CS405-8A-T Strobe, 110 Cd, Outdoor, Red Mounting Accessories 449 Surface Mount Box, Gray, Outdoor, ('CS' models only) 1(0.4) Contact us... Phone: 1-800-336-4206 Web: www.edwardssignallna.com Edwards Signaling is an EDWARDS brand. 3 Farm Glen Boulevard Farmington, CT 06032 In Canada, contact Chubb Edwards... Email: inquines@chubbedwards.com Web: www.chubbedwards.com © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Page 4 of 4 DATA SHEET S85001-0305 Not to be used for installation purposes. Issue 8 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE h' LISTING No. 7125-1657:0184 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST" 202, 203, 405, C5405, 757; "Mirtone" MS, 4M5; and "Edwards" 2400, 2440, 2441 strobe lights. Unit may be followed by A through Z to specify markets and no suffix, B, R or W to indicate product color. Models list below: 202-3A, -3A-T, *4A..T -5A, -5A-T, -6A, -6A-T, -7A, -7A-T, -8A, -8A-T; 203-8A 405-3A, -3A-T, *..4A..T -5A, -5A-T, -6A, -6A-T, -7A, -7A-T, -8A, -8A-T CS405*4AT, -7A-T, 8A-T 757-3A, -5A, -6A, -7A, -8A 2440-A, -H, -L, -M; 2440S-15, -30, -15/75, -60, -110 2441S-15, -15/75, -30, -60, -110 MS-3, -5, -6, -7, -8; 4MS-3, -5, -6, -7, -8 202-15PS, 202-15PSW, 202-75P5, 202-75PSW Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Candela rating for wall mount: -5A, -5, -15, -L, -15PS, -I5PSW: 15cd -3A, -3, -30: 30cd -6A, -6, -60: 60 cd -7A, -7,-15/75, -M: 15/75cd *..4A -75PS, -75PSW: 75cd -A, -H, -8A, -8, -110: 110cd Candela rating for ceiling mount: -3A, -3, -30: 15cd -6A, -6, -60: 30cd -H, -8, -8A, -110: 60cd -7A, -7, -15/75, -M: 15/75cd Electrical: 20-24 VDC except for Models 203-8 & 2440-A are 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances 7-29-10 ma STI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1657:0184 Page 2 of 2 and in a manner acceptable to the authority having jurisdiction. All units are intended for wall mounted installations. The following Models with suffix -8, -8A, -110, -H, -6, -6A, -60, -3, -3A, -30, -7A, -7, -15/75 re also suitable for ceiling mount. The candela ratings for these strobes are reduced as shown under rating. MARKING: Listee's name or Mirtone, model number, candela/electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible control units. Suitable for the hearing impaired application. Models with a candella rating of 15cd are for indoor use only. All other models are designed for indoor and outdoor use. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. NOTE: FORMERLY: 7125-1591:184 and 7125-1388:208 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division