HomeMy WebLinkAbout2810 CARIBOU CT; A | C | E; FPC2019-0287; Permit(City of PERMIT REPORT Carlsbad Print Date: 05/19/2022 Permit No: FPC2019-0287 Job Address: 2810 CARIBOU CT, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091200300 Track #: Applied: 12/19/2019 Valuation: $0.00 Lot #: Issued: 01/10/2020 Occupancy Group: Project #: Finaled Close Out: 02/28/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Maldonado, Adalmira Plan Check #: Project Title: Description: INNOVATE -SPRINKLER TI (26 HEADS, SUITES A, C, & E) Applicant: FPContractor: EPIC FIRE PROTECTION INC EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 SAN MARCOS, CA 92069-8126 (760) 310-6122 (760) 310-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov pf jcf. o 'Ll MATERIAL DATA SUBM1 77AL NNOVATIVE TI CA.LSSAD EPIC FIRE PROTECTION, INC. 7S5 TURTLE POINT WAY SAN hIARCOS, CA 320G3 (7O)31O-122 F1AX(7O)78-055S General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following; A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12.7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fined pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin-kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal-lation of sprinklersystems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Fromm The TYCO Series TY-FRG Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties ha ving jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con-dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler ( Identification Number (SIN) TY313.... Upright 5.6K, 1/2 in. NPT TV323 .... Pendant 5.6K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi 112.1 burl 250 psi (17.2 bar)' The Inaxlmumco,kiog p'sss,,,s at 250 n° (17.2 bW tnly cynics ace lien,,9 by -d—t— Lobe,ato- /ss. iflc. luLl. Discharge Coefficient K=5.6 GPM/55i5 (80,6 LPM/bar12') Temperature Rating Refer to Table A Finishes Sprinkler; Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics 51cn** Eutton. .....................Bioso/Copper Sealing A*eernbly ... Stuinleee Staol a/TEFLON Bulb ...............................Oloes Comp,noeior, SurOW, .....................20 Geflontnr ............................0720 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor. Upright (TY313) and Pendent )TY323( Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM'S Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is lobe used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright )TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler it the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam-eter of the air bubble is approximately 1/16 in. (1,6 mm)forthe 135'F (570C) and 3/32 in. (2.4 mm) for the 286'F (141 'C) temperature ratings. A leak-light 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,510 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting 10 suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin-klers In the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the Sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler tilting using Only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor-dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 710 14 lb-ft (9,5 to 19.0 Nm). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. tqca.Worldwide I Contacts www.tyco-fire.com Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage TFPI72 Page 2 of 4 Components: * Temperature rating is Pipe thread connections per ISO 7-1 - Frame 4 - Bulb indicated on Deflector can be provided on special request. 2 - 00(1011 5 - Compronnian STYLE 150120 3 Sealing Screw ESCUTCHEON PLATE 1/2" 7/16" (tt,t mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT— NOMINAl. MAKE IN ESCUTCHEON 5S2. mmlJ L1 WRENCH FLATS 1/2" NPT** DEFLECTOR* 2-7/8" (73.0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT, QUICK RESPONSE WRENCH RECESS lUSE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 6 t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 1 of 4 AUGUST 2018 TFPI72 Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a tire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of as escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in afire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-firn.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify( Sprinkler. SIN (specify), K=5.6. Quick Response, (specify) temperature rating. (specify) finish, P/N (specify, refer to Table A(. Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify') finish, P/N (specify') Specify: Style 20 Recessed Escutch- eon with (specify'( finish, P/N )specify'( Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/6' DIA. 73,0 mm) 2-114' DIA. FACE OF (57.2 mm) SPRINKLER I L...FLUSH 3/es5 f1 6 ' ... Ya 13 72 n SURFAC CLOSURE SERIES MOUNTING 1-3/8' 134.9 mInI TY-FRB PLATE FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 95 RECESSED ESCUTCHEON 2-7/8' DIA. (73,5 wtnl FACE OF SPRINKLER 2-1/4" DI FITTING (57.2 mm) -- 5l1eu1/4' \ I (7,906,4 mm) (12,7 mm) \ FLUSH I[._.1 MOUNTING SURFACE CLOSURE SERIES MOUNTING 1-3/e' (34,9 mm) Tr'-FRB PLATE 7/8"(22mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 TFP172 Page 3 of 4 Page 4 of 4 SPRINKLER FINISH (See Nate 7) FACTOR TYPE TEMPERATURE BULB LIQUID NATURALO. BRAS,L1 PLATED POLYESTER 1355F (57'C) Orange UPRIGHT 1555F (6850( Red 1/5F )79"C) Yellow 1/2 in. NPT and PENDENT (TY323) _______________ 1.2.3,4,5,5 __260-F (93-C) Green 286F (141'C( Blue RECESSED PENDENT Figu,1es4acd 135'F (57'C( Orange 1.2,3.4 155-F (68 Red 175F (79'C) Yellow 200'F (93'C) Green I. Listed by Urdeee,ilaats L,bu,atsnss. Inc.. 1505' Othuk ecmnns,, sn/nests. 2. COca by Urduu,fliur, LaUo,-aiur,ea-, It,., hr u-,, Catsuda IC-ull as O,eek Ilapu' Sp,lkIa,S. d Opp,e55) by Faue,ry Mutual 00504,06 Cs,peusben CMI as Oultu Amperes Svricklcta 4 Approved by ins City sroea,ysrk under MEA 554-OlE. 5 Vd5 App,cuad I'S' duta15. Install Jenrast Cart,sia. Eracreau, raein,,,lar,l,, Tol d1 1d-ace. 0440/a, 01.54-4,0 SoLO 6. Applause by 1,0 Isas Pocoarrien Oe,r,lesria,, psa,d svGa 0.1. NO.0940)061 aS C,oCk eeapera, Splicklets / Wits,. Pehaesr rested npnnkiurs are Soled Ce us uI sty C-UL Lielea. ins Sntinl,io,s ore eLena c-ut. L,Sled as Cs,resjen. neeistenl Sn,jnklstI ir.laiiad ,a,ifl slob hi It) in. toni 5/8 it, T-1 hnt,asr, as appinauls. S. lt,slallea a/ill, Style 2911//in 410 tiP it, letS Adiusinener 0.,resroe Escuher,eon. as applicable. Frame Irma saflont,,rsrly. Li5tlrgll and appreucla anpiy It, eels, ISpeclul 0,55,1. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Ne 77 SIN F —_XX SPRINKLER FINISH I 370 5.61< UPflIOI-IT (1/2 in.NPT) TY313 L371 5.61< PENDENT (1/2 in.NPT) TY323 tire pulls 'I' ret iso o.t77-370-4175-1 rer,,actisn. tsrceanrvle. N.- 1. Essv,t Scmisvhsta ealu', etty TABLE B SERIES TV-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION saau P,cpb,eats Psstsssae, LOla/daIS, Pa made I Tolapflcso al.215.suu-nluo a5,15•, Johnson / 010 Controls 1 NATURAL BRASS PURE WHITE (RALaOlo)' - POLYESTER SIGNAL WHITE (RAL9553( - POLYESTER JET BLACK lRALnUn5l POLYESTER 9 CHROME PLATED TEMPERATURE RATINGS 1355F (57 'C) 155'F (68'C( 175'F (79'C( 200'F 1935C1 286'F (I41'C( As ihe leading suppler of steel sprinkler pipe, we understand that there are no second &ances in fire sup3ression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose :mtIiijii'ti T1i TE91 i1iTi(lT4 Iii ' I iiitr'ii 1.295 1.65.3 1901) 2.315 1A18 1.654 2123 I - ightlh/ft) 7RecesperLift 1.481 2.073 1541 3.308 led Wn'tt1lb'ft) 1.860 2.754 3-488 4.842 H I.D.1083 - too toe 1.00 too r lift ___- 10 51 J 44 30 - 25, t(lbtL1Iengths 2148 221? 2353 (IV-,) 25_iedgths 2384 flt(tbs)24eatt1s 2.454 2,5342,690 _2.481 2,3B2 ht 2.551 2.639 J_2.802 EDDYTUREAD 40 ADVANTAGES: 1L listed IUS & Carada) and FM approved ASTM A135 and 'A795 Type E, Grade A Certified Complies with NF-43,13R and 14 lndustry-Lading bydrulic characteristics CRR of 1.0 and 'greater Al pipe NDT weld tesed OTHER BENEFITS/SERVICES: We have the most stocking locations in the industry, for best delivery and availability- Plain end cr roll groove Eddy Guard II' bacterial-resistant internal coating Custom lerigti 3ptlons Hot dippec galvanization Reddi-PiPe red or black pipe eliminates field pain Compatible- for use in wet dry, F reaction and luge sorrikler systems The only maker with EPDs (to help earn LEED points) U C L.•U3 LISTED 4 Of" Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from , B abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily A A installed around pipe. (2/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel 2 INC P'F 2 2 1H 2 'J B 'H PIPE and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4' thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SF 69 Type 10 Maximum Temperature - 650°F Finish - Mu. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200WON, Order By - Figure number and pipe size / Dimensions 'Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31I 2 /8 400 11 3/4 3/8 8mm or 10mm 31/a 21/2 400 11 1 3/8 8mm or 10mm Y18 2118 400 12 11/4 3/8 8mm or 10mm 33/4 2118 400 13 1/2 3/8 8mm or 10mm 31/ 2/ 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 2'/2 3/8 10mm 55/8 4'/a 600 27 3 3/8 10mm 57/s 4 600 29 31/ 3/8 10mm 73/s 51/ 600 34 4 3/8 10mm 73/s 5 1000 35 5 1/2 12mm 91/ 61/4 1250 66 6 1/2 12mm 10V8 6/4 1250 73 8 1/2 12mm 131/a 8/4 1250 136 Main Office/Manufacturing Facility. rm 'i:1I1Ii'.r A.'e • (:1,-ill. (:r\ 9219 • P11 fl/ 'P• • r1 ppp ,'i * Customer Seraice • "i1 i' wwwtolcacotn Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing - Finish - Electro Galvanized . Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length 3/8" thru 7/8' rod in 1" inc171nts Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Ga Ivan ized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec, Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8' thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 718 3770 3360 169 1 4960 4420 222 1/4 8000 7140 360 11/2 11630 10370 510 Main Office/Manufacturing Facility. 131 .iI1p;in f •Cntnnn.C1 g239. Ph 9N 13/13 •Fl.%nto Customer Service 13130 /1313 200 wwwtoca corn 1$MMYS APPROVED 8007957 GST 10 X CPVC 1-1/2 300 1.5 -8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST20 X 2-1/2 850 1.5 8068925 GST20SS X 2-1/2 850 1.5 8010957 GST30 X 4 1500 1.5 -8009925 GST25-380 X 4 1500 1.5 -8022925 SWG 25-380 X 3-1/2 - 4 1500 1.5 -8021957 SWG 20 X 2-1/2 3** 1250 1.5 8073925 SWG 2OSS X 2-1/2 1250 1.5 8139957 SHGST20 X 3 1050 1.5 8141957 SHGST30 X 4 1500 1.5 8140957 SHGST20SS X 3 1050 1.5 8142957 SHGST30SS X 4 1500 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 8038957 DSTR1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR I X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 8059957 CST 20 X 4 1475 3000 PSI 8061957 SWC20 X 4 1475 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" iTWB UiIdeX UL and FM tests were performed in compliance with NFPA-13 Standards. WWW.itWbuildex.com Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. 800-284-5339 SSS26 J 1 of 3 2o13 HOLE CUT SYSTEM G:SA I I8iLW'.7H MODEL V-723 SADDLE LET I MECHANICAL TEE NGS 40 HOLE CUT SYSTEM MODEL V.723 SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9601 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com 1. DESCRIP11ON VGS6 Model V-723 Saddle Let small mechanical tees are available In sizes 1-1/4' through 2-1F2. The Models V-723 mechanical tees provide an easy take-out of a branch outlet without the need for welding. VGS° Mechanical Tees are manufac- tured at 1S09001 certified facilities an are designed to conform to ASTM and other standards where applicable. Threads are NPT per ANSI 81.20.1. 2. LISTINGS AND APPROVALS cus Guide No. V1ZM Class 1920 3. TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile Iron conforming to ASTM A538 Grade 65-45-12 Standard black finish Hot dipped Zinc galvanized versions are available (conforming to ASTM A 153); when ordering, add a 'G" suffix: 10 the Model number. Modal V-723 Rubber compound EPDM Grade S conforming to ASTM D2000, A/A CSOB, Mechanical Tee NSF 81 and IAPMO. Nuts and Bolts: Zinc plated, Carbon Steel conforming to ASTM A183 Grade 2 (UNC nuts and bolts are a silver chromate color and ISO are a gold chromate color) In mnt I Imont 1.25'x 0.5 1.18 187 3.0 22 163 '1 20-22 08 (32015) (30) (46) (89) (56) 1421 (3/80) 127-301 (541) 1.25 x 0.75 116 1.87 35 2.2 1.63 U-Bat 20-22 1.0 (32020) )30) (48) (80) (56) (42) 13/8al 127-30l 10401 12501 1.18 2.04 30 2.2 1.73 U-Bet 20-22 1.0 (32 020) (30) (62) (66) (56) (44) (3/So) (27-30) (0.) I.6 n08 1.18 204 30 2.2 1.78 U-BuS 20-22 0.6 (40u16) (30) (52) (86) (58) (48) (3/80) (27-30) (0.41) 1.6o075 1.18 2.04 is 2.2 1.78 U-Bun 20-22 0.8 1400201 (30) 1 (52) (88) (58) (46) 1 (3/8e) 127-301 (0.41) 1501 1.18 204 35 2.2 1.68 U-BoIl 20-22 0.6 (400 25) (30) (62) (86) (56) (43) (3/80) (27-30) (0.41) 2005 118 230 3.86 2.2 2.07 U-e0 20-22 0.8 (50 (30) (58) (86) (58) (53) (3/86) (27-30) (0.41) 20 0.70 118 230 3.60 2.2 2.07 U-Soft 20-22 0.6 (500 20) (35) (55) (55) (56) (53) (3/8o) (27-30) (0.41) 20 1 119 2.30 3.86 2.2 1.87 U-Soft 20-22 1.0 (508 )__ (30) (58) (58) (56) (50) )3/8e) (27_30) (0.45) 2,500.6 1.16 245 4 37 2.2 2.22 U-Bun 25-22 1.0 (85u 15) (30) (83) (111) (58) (67) (3/80) (27-30) (0.45) 2.500,75 1.16 2.48 4.37 2.2 2.22 U-BoO 20-22 1.0 )65n 2!)_.. (30) (63) (111) (58) (57) (3/80) (27-35) (0.45) 2.501 1.18 2.48 437 2.2 2.13 U-5O 20-22 1.0 (85s25) (30) (63) (lii) (58) (54) (3/801 (27-30) (0.45) 'Hula diameters are suggested hole new dlorrretere "1 Take-out (Corder 01,00 to and of pipe to be engaged) The Viking Corporation, 210 N industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-6464 Fax: 289-818-1680 Email: techsvcsviklngcorp.com 4. HOLE CUTtiNG The hole-cut method of pipe preparation is required when using mechanical tees, mechanical crosses, and saddle-lets. The method of pipe preparation requires the cutting or drilling of a specified hole size on the centerline of the pipe. Always use the correct hole saw size as shown this data sheet and never use a torch for cutting e hole. After the hole has been cut all rough edges must be removed and the area within 5/8(16mm) of the hole should be Inspected to ensures clean smooth surface, free of any indenta-tions or projections that could affect proper gasket sealing. The area within the 'A' dimension should also be Inspected and must be free for dirt, scale or any Imperfection that could affect proper seating or assembly of the fitting. 5. INSTALLATION NOTES: Use a wrench to hold the threaded outlet In piece when Installing the sprinkler. Tighten thu nuts evenly. 71.n.t spri"int.lI nklm'directly Into Saddle-Let 1' outlet. Hole Gasket Threaded outlet Nuts Sprinkler -" Figure 1: V-723 Saddle-Let Installation The latest V08 Technical Data can be scessed at httpdlwww.elkinggreupinc.com. Scan no visit our Mobile webalte: Illa NMI Form No. F_110515 16.12.08 Rev 16.1 Replaces Form No. F_110515 Rev 15.1 Form No. F_110515 18.12.08 Rev 16.1 (Added K-factor limit table and flow data) 3 of 3 H LE CUT SYSTEM II[UI7W MODEL V.723 SADDLE LET 8JGiS MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: tochsvcs@vlklngcorp.com 6. FLOW DATA Flow test data has shown that the total A Formulas forCe Values: head loss between point A and B for the fittings can be expressed in terms AP = Where: of the pressure difference across 0 Flow (GPM) the inlet and branch. The pressure AD - Pressure Drop (psi) difference can be obtained from the Q=Ce x p C - Flow Coefficient relationship below. / Form No. F 10515 16.12.08 Rev 16.1 Replaces Form No. F_110515 Rev 15.1 (Added K-factor limit table and flow data)