HomeMy WebLinkAbout2810 CARIBOU CT; ; FPC2020-0006; PermitPERMIT REPORT (äty of Carlsbad Print Date: 05/19/2022 Job Address: 2810 CARIBOU CT, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2091200300 Track #: Valuation: $4,775,784.50 Lot #: Occupancy Group: Project U: DEV2018-0203 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check #: Project Title: CARLSBAD OAKS LOT 4 Description: CARLSBAD OAKS INNOVATION PARK -LOT 4 SPRINKLER MONITORING Applicant: CHULA VISTA ALARM INC TAYLOR BARDER 6175 PROGRESSIVE DR SAN DIEGO, CA 92154-6649 (619) 585-9111 Permit No: FPC2020-0006 Status: Closed - Finaled Applied: 01/09/2020 Issued: 02/04/2020 Finaled Close Out: 05/19/2020 Final Inspection: INSPECTOR: Salcedo, Felix Maldonado, Adalmira FPContractor: CHULA VISTA ALARM INC 6175 PROGRESSIVE AVE, U STE 400 SAN DIEGO, CA 92154-6647-SAN DIEGO (619) 585-9111 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov fft,202.o -000, Potter IPA-60 Fire Alarm System Equipment NEW EQUIPMENT LIST Model # Description Mfg. CSFM# IPA-60 Fire Alarm Control Panel Potter 7165-0328:0500 UD-2000 DACT Module Potter 7300-0328:0515 LE40 10CF Universal Communicator TYCO/DSC 7300-1273:0506 BW-DOCBOX Document Cabinet Mier N/A PAD100-PSDA Manual Fire Alarm Box Potter 7150-0328:0201 (Manual Pull Station) PAD 100-PD Photoelectric Smoke Potter 7272-0328:0504 Detector PAD100-6DB Smoke Detector Base Potter 7300-0328:0502 PAD100-SIM Single Monitor Module Potter 7165-0328:0500 PAD100-MIM Mini Monitor Module Potter 7165-0328:0500 Central Station UL Certificate of Compliance (E)POTTER The Symbol of Protection IPA-60 Fire Alarm Control Panel Features 60 addresses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class A or Class B for SLC, P-Link and NACs 5 Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at I Amp each, ideal for manual release and abort Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event History Buffer Cabinet will house up to 18 AU batteries Optional two line DACT with UD-2000 that can report General, Zone or Point Information Built in IP Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information <zE> () • Product includes 5 year warranty. UUKL Listed for Smoke Control APPROVED LISTED Description The IPA-60 is an analog/addressable releasing fire alarm system with a total system capacity of 60 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The IPA-60 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the IIOs are rated at I Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The IIOs are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA-60 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-1000 may be used to extend releasing capability. The NACs may be expanded using the PSN- 1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the IPA-60 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Technical Specifications Dimensions 16"W x 17H x 3 7/"D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA 5 Amps power for NACs, I/O, and P-Link Battery 3 Amps per NAC, regulated I Amp per 1/0 circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of I Amp Temperature and 32° to 120° (0°C to 49°C) with a maximum Humidity Range humidity of 93% non-condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Sta- tion (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Standards Automatic (A), Manual (M), Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pot), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9119 PAGE IOF4 (E)POTTER IPA-60 The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 60 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD 100-PHD Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector. PAD 100-1-ID Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F. PAD 100-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD 100-DUCT Addressable Duct Smoke Detector. PADI00-613 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PADI00-413 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD 100-113 Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PADIOO-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125 VAC. PAD 100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DO Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD IOOLFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) PADIOO-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Modules Device Description PAD 100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD 100-PSDA Dual Action Addressable Pull Station. PADIOO-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD IOO-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD I00TRT1 Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125 VAC. Also provides two contact inputs. PAD100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD 100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PADIOO-IM Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD00-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at I25VAC. PADIOO-LED Module provides a single addressable LED that is controlled by the control panel. PAD100-SM Speaker Module provides switching for two audio channels. PAD100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD100-OROI One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125 VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 2OF4 (E)POTTER IPA-60 The Symbol of Protection Fire Alarm Control Panel SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green Alarm - Red Earth Fault - Amber Supervisory - Amber Silenced - Amber Trouble - Amber Pre-Release - Amber Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The IPA-60 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: RA-6075R —2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) - 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the IPA-60 as releasing circuits. CA-6075 - Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 - UL listed, Dual line telephone alarm communicator DRV-50 - LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 - Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 - Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three IPA series panels to share a single reporting technology. IDC-6 - Initiating device circuit provides 6 programmable inputs AE-2 - Two card expansion cabinet AE-8 - Eight card expansion cabinet AE-14 - Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA-60 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 3OF4 ,0 RIGHT SIDE (E)POTTER IPA-60 The Symbol of Protection Fire Alarm Control Panel Dimensions 0 01 TOP •o DEPTH =3.75" 000R= 16.07" BACKBOX = 15.77 DEPTH = 3.84 LEFT SIDE o BOTTOM DWG #593-I Ordering Information Model Description Stock No. IPA-60 Fire Alarm Releasing Control Panel 3992714 Replacement Board IPA-60 3992738 Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 732 18BN4U1'1LVN0C112CZ 732 I2BN4TNLVNOC322C2 Victaulic 753-E Series Mini Max MX 123 & MX200 wl 8876677 & 889323 Viking 11591, 11601, 11602, 13843,& 13844 TLX PA0036 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 . www.pottersignal.com 8830101-REVG • 9/19 PAGE 4OF4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I Ila FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0500 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: biIIwpottersignal.com DESIGN: Models IPA-60, IPA-1 00, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD 100-LED Addressable LED Module PAD 100-OROl One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *5LCE127 Loop Expander RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ?V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER UD-2000 The Symbol of Protection Digital Alarm Communicator Features Allows for communication to Monitoring Station Communicates using SIA-DCS or Ademco Contact ID Protocols For use with IPA, AFC, and ARC series Addressable Panels and PFC-4064 Conventional Panel Status LEDs indicate operation of DACT card Installs with ease behind main panel LCD display via User Interface bracket Device address is set internally to address I Includes two (2) RJ45 phone cords Lxt Description The UD-2000 Digital Alarm Communicator Transmitter (DACT) provides for up to two (2) phone lines for communication to a monitoring station. The UD-2000 communicates using the SIA- DCS or Ademco Contact ID protocols. When enabled, the DACT automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the communication is complete, the DACT will hang up. The DACT is provided with terminal blocks for each phone line and two RJ45 cords. In order for the DACT to work properly, it must be installed on a plain old telephone service (POTS) line or equivalent deemed by the authority having jurisdiction. The DACT must be installed before any other equipment to ensure it can seize the phone line. Phone lines are high voltage and should be run in a separate conduit from other circuits. The wire conductors connecting the DACT to the phone system should be 26 AWG or larger. Technical Specifications Operating Voltage 22.0-24.OV Standby Current I 6mA Alarm Current 23mA Max IJD-2000s per panel 1 Dimensions 4"W * 6"H * 1-5/8"D Operating Tempuratures 0°C - 49°C (32°F- 120°F) Operating Humidity Range 10% - 93% @ 30°C (86°F) (non-condensing) Mounting Options In FACP Behind keypad Shipping Weight 0.47 lbs Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830146- REV B • 6/19 PAGE 10F3 (E)POTTER UD-2000 The Symbol of Protection DigitalAlarm Communicator Out to Premises Phones Line In From Telco RD 1X Phone Jack to UD-2000 Plain Old Telephone (POTS) lines Tip (Brown) Ring (Grey) Out to Premises Phones Line In From Telco Installation The UD-2000 DACT is connected to the control panel using the provided four-wire cable connection (P/N 5210514) between P4 and UD-2000 P1. The connection is power limited and supervised. Power system down. Slide the UD-2000 into the card guides located under the User Interface bracket. Secure the UD-2000 to the User Interface bracket using the provided #6-32x3/8" screw Install the provided four-wire conductor jumper between UD-2000 P1 and P4. Potter Electric Signal Company, LLC • St. Louis, MO Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830146- REV B • 6/19 PAGE 2OF3 P Connector on main board T Slides In guides under ,rein buurd. Screw RYU H -, - a o DD a • ODD ci E) LEI a I 0 DWG #593.32A P Connector on small platform control panel 0 cW) (E)POTTER The Symbol of Protection U D-2000 Digital Alarm Communicator UD-2000 DACT Installation on UD-2000 DACT Installation on Small Platform Panel Large Platform Panel Fig 1 Fig 2 Ordering Information Model Description Stock No. UD-2000 Digital Alarm Communicator 3992769 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956.1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830146- REV H • 6/19 PAGE 3OF3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0328:0515 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw@pottersignal.com DESIGN: Models UD-1000 and *UD..2000 Digital Alarm Communicator Transmitters (DACT). Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, rating and UL label. APPROVAL: Listed as a digital alarm communicatior for use with listees separately listed fire alarm control panels. Refer to listee's Installation Instruction Manual for details. Rev 01 -09-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VA operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Dec From Tyco Security Products Ensure your installations are future-ready, with LTE Features That Make a Difference: Uses LTE network for high- speed, reliable and low-cost communications to an IP receiver Automatically switches to 3G (HSPAJHSPA+) if LIE service is not available Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via website or mobile interface provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System l-IP/11/111/IV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed CSFM listed Due to rapidly-evolving cellular technologies, 2G/3G network sunsets are already on the horizon - with some having already been completed. Now's the time to adopt and adapt. Switch to LTE today, to offer customers long-lasting investment protection, and reduce your future truck rolls. The LE401 OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System 1-IP/11/I1 l/IV/5). The LE401 OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format. The LE401 OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010, 2013, and 2016 editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013/2016) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The LE401OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the LE401 OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. From Tyco Security Products In instances where the control panel does not support Contact ID or SIA (300 baud), the LE401 OCF has inputs pre- set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station receiver (Sur-Gard® System l-IP/11/111/IV/5). Activating & Initializing the Unit Activating and initializing the LE40100F can be done using the website interface provided by C24 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. -0 UL Listing The LE401OCF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the LE401OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013/2016 guidelines the LE401OCF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the LE401 OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The LE401 OCF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: LE4O1OCF-AT .............. Universal Wireless Commercial Fire Alarm Communicator Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the LE401OCF requires use of the 4M (NFPA72 2010) or 500kB (NFPA72 2013/2016) rate plans to support the supervision requirements. Specifications Dimensions ................................................ 11-1/2 x 10 x3 (290 mm x 254 mm x 75 mm) Input Voltage.............................................................120 VAC Current Draw ..............................................200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (00 to 49° C) Weight...........................................................12.8 lbs (5.8 kg) Optional Acessories Model Description LIE-i 5ANT 15 ft extension antenna LTE-25ANT 25 ft extension antenna LTE-50ANT 50 ft extension antenna CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL T - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1273:0506 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Tyco Safety Products Canada Ltd.3301 Langstaff Rd., Concord, Ontario L4K 41_2 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Model LE4010CF LTE interface. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a interface for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. O1-11-l8gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division WA l;iJa3Taf BW-DocBox (15"Wx 13"Hx 4"D) includes: Three labels: "Fire Alarm Documents" "As-B u It Permits" "Test and Maintenance Documents" An adjustable bungee allows you to lit various sizes of binders, documents, smoke-cans, etc. A door bracket holds two CDs, three sets of keys and more documents A cam lock with two keys BW-DocBox2 (1I"Wx 15"Hx4"D) Smaller and more basic model without the door bracket for CDs and key sets. However, it does have the three labels, adljLlstable bungee and a lock with two keys. )on't see the box you want? Customization, special colors, anchor silk-screening of logos are :all us or visit our website available for quantities of 23 or more. (requires lead time( 800-473-0213 E-mail: infoitmierproducts.com PADI 00-PSSNPSDA IDPOTTER Addressable Pull Station The Symbol of Protection Single/Dual Action Features Single or Dual Action versions Durable die-cast construction Reset key matches the fire alarm control panels Compatible with IPA Series panels SLC Class A, Class X & Class B Product includes a 5 year warranty LISTED Description The PADIOO-PSSA (Single Action) is activated by simply pulling the white "T" bar handle down. The PAD 100-PSDA (Dual Action) is activated by lifting the front cover and then pulling the white "T" bar handle down. Once activated, the "T" bar cannot be reset without opening the front cover. Opening the front cover will also activate the pull station. To reset the PAD 100-PS Series, use the Potter WS-93 key to unlock and open the front cover. Once the cover is open, push the "T" bar back into the normal position and re-secure the front cover. Application The PAD100-PSSAIPSDA is compatible with Potter's IPA series addressable fire alarm control panels. It is a non-coded addressable pull station available in either a single or dual action model and installs on a single gang box or surface mounts using the P32-BB or P32-DBB (deep) back box. Technical Specifications Operating Voltage 24.0 VDC Max SLC Standby Current 200uA Max SLC Alarm Current 200uA 32°F - 120°F (0° - 49°C) Environmental Limitations Indoor Only Dimensions 4.75" H x 3.25" W x 1.75" D Relative Humidity Range 0 - 93% (non-condensing) Mounting Options Single gang box or Potter P32-BB/DBB Shipping Weight APS-SA- 1.22 lbs. APS-DA - 1.46 lbs. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830097 - REV A • 03/16 PAGE 1 OF 2 PAD 100-PSDA Pull Station Back View and Wiring Fig Pra PAD 100-PSSA FACTORY WIRED CONTACTS (E)POTTER PADI Addressable Pull Station The Symbol of Protection Sin gle/DualAction Setting the Address The PAD 100-PS Series uses one SLC address assigned to the device. The address is set using the DIP switch located on the back of the PAD 100-PS device. Pull Station Front View Fig - Ii FROM FACPOR PREVIOUS DEVICE TO NEXT DEVICE n Ordering Information Model Description Stock No. PADIOO-PSSA Addressable Pull Station, Single Action 3992721 PAD 100-PSDA Addressable Pull Station, Dual Action 3992720 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 • www.pottersignal.com 8830097 - REV A • 03/16 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0328:0201 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: biIIwpottersignaI.com DESIGN: Models APS-SA, *PAD100pSsA single action and APS-DA, *PADIOOPSDA dual action addressable pull boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 22-24 VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed addressable pull boxes for use with separately listed and compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. *Revision 02-10-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER PADI 00-PD The Symbol of Protection Photoelectric Smoke Sensor Features Low profile, less than 2 inches with the base Wide selectable sensitivity range of 1.0 to 3.70/o/foot Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting, no programming tool required LED alarm indicator Product includes a 5 year warranty F11 LISTED Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD 100-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD100-PD has a sensitivity range of 1.0 to 3.7 % per foot and is UL. The PADIOO-PD features drift compensation and has built in dirty detector warning as well as. The PADIOO-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PADIOO-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: Power to the device is removed Field wiring is correctly installed. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24 VDC Alarm indicator 1 LED Alarm set-point range 1.0 to 3.7%/ft 3.6-12 %/m Installation temperature 32to 120 0 F/ 0to49°C range Operating relative 0% to 93% (Non-condensing) humidity range Start-up time Max. I sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) lOig (3.560z) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 • www.pottersignal.com 8830108- REV A • 03/16 PAGE IOF2 (E)POTTER PADI 00-PD The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratings The PAD IOO-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD 100-PD will operate even though the LED may not illuminate. Operation The PAD100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will latch steady if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD IOO-PD with the PAD 100-4DB or PAD IOO-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PADIOO-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD 100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE: As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD 100-41313 4" Standard Base 3992731 PAD 100-61313 6" Standard Base 3992732 PAD I00-113 6" base with an isolator module included. 3992730 PAD 100-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125 VAC 13992728 PAD 100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 Ordering Information Model Description I Stock No. PADIOO-PD Photoelectric Smoke Sensor 13992733 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignaI.com 8830108-REVA • 03/16 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0328:0504 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Models PAD100-PD, PAD100-DD and PAD100-PHD photoelectric smoke detector heads. Model PAD 100-PHD has an intergral heat detector. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models PADIOO-PD and PAD100-PHD are listed as photoelectric smoke detector heads for use with listee's detector base Models PADI00-4DB, PAD100-6DB, PAD100-RB, PAD1 00-SB (CSFM#7300-0328:502) and Model PAD 100-lB (CSFM#7300-0328:501). Model PADIOO-DD is listed as a photoelectric smoke detector head for use with Model PAD100-DUCT (CSFM#3248-0328:0505). Refer to listee's Installation Instruction Manual for details. 06-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER The Symbol of Protection Features Terminals Marked with Polarity to assist with installation Duplicate terminals for in and out SLC wiring Terminals accept 22 to 12 AWG wire sizes Installs on single gang, double gang, octagon or 4" square box Locking tab prevents unauthorized detector removal Product includes 5 year warranty PADI 00-4DB/6DB 4"/6"Addressable Detector Base <a> APPROVED LISTED Application The Potter PAD 100-6DB and PAD 100-4DB detector bases are used to install Potter's addressable smoke and heat detectors. The PADIOO- 6DB will mount on a single gang, double gang, octagon or 4" square electrical box. Description The PADI00-6DB and PAD100-4DB are low-profile, surface mount bases used with Potter's addressable detectors. The base uses screw- clamp terminals that accept wire ranging from 22 to 14 AWG. When installed on recessed electrical boxes the PAD 100-6DB is wide enough to completely cover the back box and the immediate surrounding area. The base is equipped with a locking tab to deter unauthorized removal of the attached detector. Technical Specifications Mounting Options Single gang, double gang, octagon, and 4" square box Terminals Screw-Clamp Type Wire Guage 22 to 12 AWG Diameter: 6.3 in (166 mm). Dimensions Height 0.72 in (18 mm) Shipping Weight 87g (3.07 oz) Material Durable Plastic Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com PRINTED IN USA 8830107- REV C • 12/18 PAGE I OF 2 (E)POTTER PADI 00-4DB/6DB The Symbol of Protection 4 "/6 "Addressable Detector Base Locking Feature The PADI00-6DB and PAD100-413B include a locking feature that prevents removal of the detector without using a tool. To eliminate this feature, break off the locking tab (refer to Figure 1), and then install the detector. Fig. 1 Break off tab (gray area) in image to disable locking feature. To remove the detector from the base when the locking feature has been enabled, insert a small screw driver into the slot on the base to push the plastic tab while simultaneously turning the detector head counter-clockwise. Fig. 2 Wiring Diagram Fig. 3 To FA( Loop ( Ordering Information Model Description Stock No. PAD 100-6DB 6" Sensor Base 3992732 PADI004DB 4" Sensor Base 3992731 Insert small screwdr into slot to remove detector from base. Potter Electric Signal Company, LLC St. Louis, MO . Phone: 800-325-3936 . www.pottersignal.com PRINTED INUSA 8830107- REV C • 12/18 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0328:0502 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Models PAD100-4DB, PAD100-6DB, PADIOO-RB and PAD100-SB detector bases. Referto Listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a addressable isolator base for use with separately listed compatible fire alarm control units and listee's separately listed Models PAD-100-PD and PAD-100-PHD (CSFM#7272-0328:0504), PAD-100-HD (CSFM#7270-0328:0503) and PAD-100-CD (CSFM#5278-0328:0506) detector heads. Refer to listee's Installation Instruction Manual for details. 06-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER PAD 1 00-SI M The Symbol of Protection Single Input Module Features One (1) Class B monitoring input SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG Product includes a 5 year warranty NOTE: This addressable module does not support 2-wire smoke detectors. Description The PAD 100-SIM uses one (1) SLC loop addresses when monitoring one (1) Class B circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring one (1) Class B circuit. The PAD100-SIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The PAD100-SIM is compatible with Potter's IPA series addressable fire alarm control panels. The PAD100-SIM is an interface module used to monitor dry contact devices such as sprinkler waterfiow, valve tamper switches, or conventional pull stations. The module is capable of monitoring one Class B circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 100-SIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. to LISTED Technical Specifications Operating Voltage 24.OV Max SLC Standby 2401iA Current Max SLC Alarm 240p.A Current Max Wiring Resistance 1000 of IDC Max Wiring I iF Capacitance of IDC EOL Resistor 5.IK0 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830083- REVA • 03/16 PAGE! OF 2 (E)POTTER PADI 00-SIM The Symbol of Protection Single Input Module Installation Using Compatible Electrical Box Fig I Wiring Diagram PADJOO-SIM With Class B Circuit Fig 2 Jku._1 pwt .-p Ordering Information Model Description I Stock No. PAD 100-SIM Single Input Module 3992704 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 . www.pottersignal.com 8830083- REVA • 03/16 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0500 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw@pottersignal.com DESIGN: Models IPA-60,IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD 100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *SLCE 127 Loop Expander RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER PAD 100-MI M The Symbol of Protection Micro Input Module Features One Class B contact monitoring input Small size allows mounting in most electrical boxes SLC Class A, Class X & Class B 6" Pigtail wiring connections Product includes a 5 year warranty 12 PAD 100-MIM (SLC Module) II H LISTED Description The PADIOO-MIM is used to monitor the status of an initiating device(s) that contain a normally open set of dry contacts. The module is enclosed in a plastic case to protect against inadvertent shorts and ground faults. The case can be mounted using a single screw. The PAD 100-MIM has a status indicator LED to indicate communication and alarm condition. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The micro input module (PAD 100-MIM) is compatible with Potter's IPA series addressable fire alarm control panels. Generally the PADIOO-MIM is used to monitor pull stations and other devices where the module is installed in an electrical box or enclosure behind the device being monitored. Technical Specifications Operating Voltage 24.OV Max SLC Standby 200A Current Max SLC Alarm 20011A Current IDC Input Circuit Class B Wiring Max Wiring Resistance 100g2 of IDC Max Wiring I gF Capacitance of IDC EOL Resistor 5.1K9 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 1.75" (44.5mm)L x 1.36" (34.5mm)Wx .43" (llmm)D Mounting Options 2-1/2" (64mm) deep single-gang box Shipping Weight 0.3 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830079- REVA • 03/16 PAGE I OF 2 (E)POTTER PAD 100-MI M The Symbol of Protection Micro Input Module Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the front of the PAD 100-MIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Wiring Diagram Fig I FROM FACP OR PREVIOUS - TO NORMALLY OPEN DEVICE AND TO NEXT DEVICE MONITORED DEVICE 5.1K OHM REQUIRED Part #3005013 Ordering Information Model Description Stock No. PAD 100-MIM Micro Input Module 3992700 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830079- REV A • 03/16 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0500 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw@pottersignal.com DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD 100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *5LCE127 Loop Expander RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division U L Applicant ID No: 892912-001 I Service Center No: I I Expires: 31-MAR-2020 I CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service ComDanv indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: HUNTINGTON BEACH, CA (HUNTINGTON Alarm Service Company: (892912-001) Service Center: (892912-001) GENERAL MONITORING SERVICES INC GENERAL MONITORING SERVICES INC 17951 LYONS CIR 17951 LYONS CIR HUNTINGTON BEACH CA 92647-7167 HUNTINGTON BEACH CA 92647-7167 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S7894i UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling / Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31MAR2020*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" PROJECT: Shell Construction Carlsbad Oaks Innovation Park Lot 4 2810 Caribou Court Carlsbad, CA 92108 SYSTEM: SPRINKLER MONITORING SYSTEM INSTALLATION SUBMITTED BY: CVA Security 6175 Progressive Avenue Suite 400 San Diego, CA 92154 PHONE: (619) 585-9111 DATE SUBMITTED: December 30, 2019 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. PROTECTED PROPERTY INFORMATION Name of property: Carlsbad Oaks Innovation Park Lot 4 SHELL Address: 2810 CARIBOU COURT, LOT 4 CARLSBAD CA 92010 Description of property: SHELL BUILDING Occupancy type: B, 51 Name of property representative: BADIEE DEVELOPMENT Address: 1261 PROSPECT ST. STE 9 LA JOLLA CA 92037 Phone: 7607170615 Fax: E-mail: Authority having jurisdiction over this property: CITY OF CARLSBAD Phone: 7606024663 Fax: E-mail:______________ FIRE ALARM SYSTEM INSTALLATION, SERVICE, AND TESTING INFORMATION Installation contractor for this equipment: OVA SECURITY Address: 6175 PROGRESSSIVE AVE STE 400 Phone: 6195859111 Fax: E-mail:............. Service organization for this equipment: OVA SECURITY Address: 6175 PROGRESSIVE AVE STE 400 Phone: 6195859111 Fax: E-mail:__________________ Location of as-built drawings: DOC BOX Location of historical test reports: DOC BOX Location of system operation and maintenance manuals: DOCUMENT BOX A contract for test and inspection in accordance with NFPA standards is in effect as of MARCH 2020 Contracted testing company: CVA SECURITY Address: 6175 PROGRESSIVE AVE STE 400 SAN DIEGO CA 92154 Phone: 6195859111 Fax: __________E-mail:_____________ Contract expires: Contract number: _______Frequency of routine inspections: TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter Reference of System Type: FIRF SPRINKI FR SYSTFM Name of organization receiving alarm signals with phone numbers (if applicable): Alarm: GMS MONITORING Phone: 18886609111 Supervisory: Phone: Trouble: Phone: 1 40 Entity to which alarms are retransmitted: Phone: - TYPE OF FIRE ALARM SYSTEM OR SERVICE (CONTINUED) Method of retransmission of alarms to that organization or location: If Chapter. 8, note the means of transmission from the protected premises to the central station: Digital alarm communicator U McCulloh U Multiplex U 2-way radio U 1-way radio II N/A If Chapter 9, note the type of connection: LJ Local energy U Shunt EI N/A 3.1 System Software Operating system (executive) software revision level: N/A Site-specific software revision 'date: N/A Revision completed by: N/A SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to this system (see NFPA 72, Table 6.6.1): Quantity: I Style: y Class: B ALARM-INITIATING DEVICES AND CIRCUITS Characteristics of initiating device circuits connected to this system (see NFPA 72, Table 6.5): Quantity: 3 Style: Y Class: B 5.1 Manual Initiating Devices 5.1.1 Manual Pull Stations Number of manual pull stations: 1 Type of devices: EAddressable U Conventional U Coded U Transmitter L N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: 1 Type of coverage:)Q Complete area J Partial area U Nonrequired partial area L N/A Type of devices: I Addressable U Conventional L Coded U Transmitter 11 N/A Type of smoke detector sensing technology: CJ Ionization Photoelectric 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: Type of coverage: Type of devices: U Addressable U Conventional 0 Coded D Transmitter U N/A Type of smoke detector sensing technology: U Ionization U Photoelectric 5.2.3 Heat Detectors Number of heat detectors: N/A Type of coverage: E1 Complete area U Partial area U Nonrequired partial area U N/A 5. ALARM-INITIATING DEVICES AND CIRCUITS (CONTINUED) 2 Type of devices: 121 Addressable U Conventional L Coded U Transmitter U N/A 5.2.4 Sprinkler Waterfiow Detectors Number of waterfiow detectors: I Type of devices Addressable U Conventional U Coded U Transmitter Q N/A 5.2.5 Alarm Verification Number of devices subject to alarm verification: Alarm verification on this system is: ID Enabled U Disabled U Set for seconds SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUITS 6.1 Sprinkler System Number of valve supervisory switches: 2 Type of devices: 121 Addressable D Conventional U Coded Q Transmitter U N/A 6.2 Fire PUMP N/A Type of fire pump: C3 Electric Diesel Type of fire pumps supervisory devices: U Addressable U Conventional Coded U Transmitter U N/A Fire Pump Functions Supervised Fire pump power Q Fire pump running U Fire pump phase reversal 1 Selector switch not in auto D Engine or control panel trouble U Low fuel Other: 6.3 Engine-Driven Generator N/A Type of generator supervisory devices: D Addressable Q Conventional U Coded Transmitter Ll N/A Engine or control panel trouble Generator running Ll Selector switch not in auto Q Low fuel Other: ANNUNCIATORS' N/A 7.1 Annunciator I U Local D Remote Type: 1J Addressable U Directory Graphic U N/A Location: 7.2 Annunciator 2 U Local Q Remote Type: U Addressable U Directory U Graphic 11 N/A Location: 7.3 Annunciator 3 L Local U Remote 3 Type: U Addressable U Directory L Graphic U N/A Location: 8. ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1 Emergency Voice Alarm Service N/A Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker zones:________________ 8.2 Telephone Jacks N/A Number of telephone jacks installed: Number of telephone handsets stored on site: Type of telephone system installed: L Electrically powered II Sound powered U N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system (see NFPA 72, Table 6.5): Quantity: Style: _Class:________________ ALARM NOTIFICATION DEVICES AND CIRCUITS (continued) 8.4 Types and Quantities of Nonvoice Notification Appliances Installed Bells: With visual device: Horns: With visual device: Chimes: With visual device: Bells: With visual device:_______ Visual devices without audible devices: Other (describe): EMERGENCY CONTROL FUNCTIONS ACTIVATED Hold-open door releasing devices U Smoke management or smoke control Door unlocking J Elevator recall U Other SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage 120 Amps 20 Overcurrent protection: Type BREAK Amps20 Location (of primary supply panelboard): HPI CKTI Disconnecting means location: 10.2 Secondary Power Location: Type:_______ Nominal voltage: ________ Current rating: Number of standby batteries: 2 Amp hour rating: 7 AMPS Location of emergency generator: Location of fuel storage: Calculated capacity of secondary power to drive the system In standby mode: 24HRS In alarm mode: 2HRS II. RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.) g1 NFPA 72 6 NFPA 70, National Electrical Code, Article 760 X1 Manufacturer's published instructions U Other (please specify): System deviations from referenced NFPA standards: Signed: Printed name: JESUS GOMEZ Date: 4/10/2020 Organization:CVA SECURITY Title: FA lNSTALLEhone: 6195859111 RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or inthe presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of: NFPA 72 NFPA 70, National Electrical Code, Article 760 Manufacturer's published instructions U Other (please specify): Documentation in accordance with Inspection and Testing Form (Figure 10.6.2.3) is attached Signed: ___Printed name: JESUS GOMEZ Date: 04/10/2020 Organization: Title: FA INSTALLERhone: CERTIFICATIONS AND APPROVALS 13.1 System Installation Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. - Signed: nted name: JESUS GOMEZ Date:411012020 Organization: Title: FA INSTALLEhone: 610559111 13.2 System Service Contractor Wi This system as specified herein has been installed and tested according to all NFPA standards cited herein. Signed: Printed name: JESUS GOMEZ Date: 4/10/2020 Organization: Title: FA INSPECTOhone: 6195859111 13.3 Central Station This system as specified herein will be monitored according to all NFPA standards cited herein. Signed: Printed name: JESUS GOMEZ Date: 4/10/2020 Organization: Title: Phone: 6195859111 13.4 Property Representative I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: _______________Printed name: Date: Organization: Title: Phone: 13.5 Authority Having Jurisdiction I have witnessed a satisfactory acceptance test of this system and find i: to be installed and operating properly in accordance with its approved plans and specifications, its approved sequence of operations, and with all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: