Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Seaside Heating & Air Conditioning Inc; 2022-10-11; PWM23-1989FAC
PWM23-1989FAC Faraday 173 A & B 3 Ton & 5 Ton Page 1 of 25 City Attorney Approved 8/2/2022 Heat Pump Replacements CITY OF CARLSBAD MINOR PUBLIC WORKS CONTRACT FARADAY MEETING ROOM 173 A & B 3 TON & 5 TON SPLIT SYSTEM HEAT PUMP REPLACEMENTS This agreement is made on the ______________ day of _________________________, 2022, by the City of Carlsbad, California, a municipal corporation, (hereinafter called "City"), and Seaside Heating & Air Conditioning, Inc., a California corporation whose principal place of business is 1359 Rocky Point Drive, Oceanside, CA 92056 (hereinafter called "Contractor"). City and Contractor agree as follows: DESCRIPTION OF WORK. Contractor shall perform all work specified in the Contract documents for the project described by these Contract Documents (hereinafter called "Project"). PROVISIONS OF LABOR AND MATERIALS. Contractor shall provide all labor, materials, tools, equipment, and personnel to perform the work specified by the Contract Documents unless excepted elsewhere in this Contract. CONTRACT DOCUMENTS. The Contract Documents consist of this Contract, exhibits to this Contract, Contractor's Proposal, the Plans and Specifications, the General Provisions, addendum(s) to said Plans and Specifications, and all proper amendments and changes made thereto in accordance with this Contract or the Plans and Specifications, all of which are incorporated herein by this reference. When in conflict, this Contract will supersede terms and conditions in the Contractor’s proposal. LABOR. Contractor will employ only skilled workers and abide by all State laws and City of Carlsbad Ordinances governing labor. GUARANTEE. Contractor guarantees all labor and materials furnished and agrees to complete the Project in accordance with directions and subject to inspection approval and acceptance by Lauren Milliken (City Project Manager). PAYMENT. The City shall withhold retention as required by Public Contract Code Section 9203. WAGE RATES. The general prevailing rate of wages for each craft or type of worker needed to execute the Contract shall be those as determined by the Director of Industrial Relations pursuant to Sections 1770, 1773 and 1773.1 of the Labor Code. Pursuant to Section 1773.2 of the Labor Code, a current copy of the applicable wage rates is on file in the Office of the City Engineer. Contractor shall not pay less than the said specified prevailing rates of wages to all workers employed by him or her in execution of the Contract. Contractor shall be responsible for insuring compliance with provisions of section 1777.5 of the Labor Code and section 4100 et seq. of the Public Contracts Code, "Subletting and Subcontracting Fair Practices Act." The City Engineer is the City's "duly authorized officer" for the purposes of section 4107 and 4107.5. The provisions of Part 7, Chapter 1, of the Labor Code commencing with section 1720 shall apply to the Contract for work. DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B 11th October PWM23-1989FAC Faraday 173 A & B 3 Ton & 5 Ton Page 2 of 25 City Attorney Approved 8/2/2022 Heat Pump Replacements A contractor or subcontractor shall not be qualified to bid on, be listed in a bid proposal, subject to the requirements of Section 4104 of the Public Contract Code, or engage in the performance of any contract for public work, unless currently registered and qualified to perform public work pursuant to Section 1725.5. This project is subject to compliance monitoring and enforcement by the Department of Industrial Relations. Contractor and any subcontractors shall comply with Section 1776 of the California Labor Code, which generally requires keeping accurate payroll records, verifying and certifying payroll records, and making them available for inspection. Contractor shall require any subcontractors to comply with Section 1776. FALSE CLAIMS. Contractor hereby agrees that any contract claim submitted to the City must be asserted as part of the contract process as set forth in this agreement and not in anticipation of litigation or in conjunction with litigation. Contractor acknowledges that California Government Code sections 12650 et seq., the False Claims Act, provides for civil penalties where a person knowingly submits a false claim to a public entity. These provisions include false claims made with deliberate ignorance of the false information or in reckless disregard of the truth or falsity of the information. The provisions of Carlsbad Municipal Code sections 3.32.025, 3.32.026, 3.32.027 and 3.32.028 pertaining to false claims are incorporated herein by reference. Contractor hereby acknowledges that the filing of a false claim may subject the Contractor to an administrative debarment proceeding wherein the contractor may be prevented from further bidding on public contracts for a period of up to five (5) years and that debarment by another jurisdiction is grounds for the City of Carlsbad to disqualify the Contractor or subcontractor from participating in contract bidding. Signature: ___________________________________ Print Name: ___Jimmie Sebring, President & Secretary _ REQUIRED INSURANCE. The successful contractor shall provide to the City of Carlsbad, a Certification of Commercial General Liability and Property Damage Insurance and a Certificate of Workers’ Compensation Insurance indicating coverage in a form approved by the California Insurance Commission. The certificates shall indicate coverage during the period of the contract and must be furnished to the City prior to the start of work. The minimum limits of liability insurance are to be placed with California admitted insurers that have a current Best's Key Rating of not less than "A-:VII"; OR with a surplus line insurer on the State of California’s List of Approved Surplus Line Insurers (LASLI) with a rating in the latest Best’s Key Rating Guide of at least “A:X”; OR an alien non-admitted insurer listed by the National Association of Insurance Commissioners (NAIC) latest quarterly listings report. Commercial General Liability Insurance of Injuries including accidental death, to any one person in an amount not less than……..$1,000,000 Subject to the same limit for each person on account of one accident in an amount not less than ….…$1,000,000 Property damage insurance in an amount of not less than……..$1,000,000 DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PWM23-1989FAC Faraday 173 A & B 3 Ton & 5 Ton Page 3 of 25 City Attorney Approved 8/2/2022 Heat Pump Replacements Automobile Liability Insurance in the amount of $1,000,000 combined single limit per accident for bodily injury and property damage. In addition, the auto policy must cover any vehicle used in the performance of the contract, used onsite or offsite, whether owned, non-owned or hired, and whether scheduled or non-scheduled. The automobile insurance certificate must state the coverage is for “any auto” and cannot be limited in any manner. The above policies shall have non-cancellation clauses providing that 30 days written notice shall be given to the City prior to such cancellation. The policies shall name the City of Carlsbad as an additional insured. The full limits available to the named insured shall also be available and applicable to the City as an additional insured. WORKERS’ COMPENSATION AND EMPLOYER’S LIABILITY. Workers’ Compensation limits as required by the California Labor Code. Workers’ Compensation will not be required if Contractor has no employees and provides, to City’s satisfaction, a declaration stating this. BUSINESS LICENSE. The Contractor and all subcontractors are required to have and maintain a valid City of Carlsbad Business License for the duration of the contract. INDEMNITY. The Contractor shall assume the defense of, pay all expenses of defense, and indemnify and hold harmless the City, and its officers and employees, from all claims, loss, damage, injury and liability of every kind, nature and description, directly or indirectly arising from or in connection with the performance of the Contract or work; or from any failure or alleged failure of Contractor to comply with any applicable law, rules or regulations including those related to safety and health; and from any and all claims, loss, damages, injury and liability, howsoever the same may be caused, resulting directly or indirectly from the nature of the work covered by the Contract, except for loss or damage caused by the sole or active negligence or willful misconduct of the City. The expenses of defense include all costs and expenses including attorneys’ fees for litigation, arbitration, or other dispute resolution method. JURISDICTION. The Contractor agrees and hereby stipulates that the proper venue and jurisdiction for resolution of any disputes between the parties arising out of this agreement is San Diego County, California. Start Work: Contractor agrees to start within thirty (30) working days after receipt of Notice to Proceed. Completion: Contractor agrees to complete work within sixty (60) working days after receipt of Notice to Proceed. /// /// /// /// /// /// DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PWM23-1989FAC Faraday 173 A & B 3 Ton & 5 Ton Page 4 of 25 City Attorney Approved 8/2/2022 Heat Pump Replacements CONTRACTOR’S INFORMATION. Seaside Heating & Air Conditioning, Inc. 1359 Rocky Point Drive (name of Contractor) 790514 (street address) Oceanside, CA 92056 (Contractor’s license number) C-20, C-38, C-4 1/31/2023 (city/state/zip) 760-643-1100 (license class. and exp. date) 1000005586 6/30/2025 (telephone no.) cb@seasidehvac.com (DIR registration number and exp. date) (e-mail address) AUTHORITY. The individuals executing this Agreement and the instruments referenced in it on behalf of Contractor each represent and warrant that they have the legal power, right and actual authority to bind Contractor to the terms and conditions of this Agreement. CONTRACTOR SEASIDE HEATING & AIR CONDITIONING, INC., a California corporation CITY OF CARLSBAD, a municipal corporation of the State of California By: By: (sign here) Jimmie Sebring, President & Secretary Paz Gomez, Deputy City Manager, Public Works, as authorized by the City Manager (print name/title) By: (sign here) Charles Balcar, Chief Financial Officer (print name/title) If required by City, proper notarial acknowledgment of execution by Contractor must be attached. If a corporation, Agreement must be signed by one corporate officer from each of the following two groups: Group A Group B Chairman, President, or Vice-President Secretary, Assistant Secretary, CFO or Assistant Treasurer Otherwise, the corporation must attach a resolution certified by the secretary or assistant secretary under corporate seal empowering the officer(s) signing to bind the corporation. APPROVED AS TO FORM: CINDIE K. McMAHON, City Attorney BY: _____________________________ Assistant City Attorney DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PWM23-1989FAC Faraday 173 A & B 3 Ton & 5 Ton Page 5 of 25 City Attorney Approved 8/2/2022 Heat Pump Replacements EXHIBIT A LISTING OF SUBCONTRACTORS BY GENERAL CONTRACTOR Set forth below is the full name and location of the place of business of each subcontractor whom the Contractor proposes to subcontract portions of the Project in excess of one-half of one percent of the total bid, and the portion of the Project which will be done by each subcontractor for each subcontract. NOTE: The Contractor understands that if it fails to specify a subcontractor for any portion of the Project to be performed under the contract in excess of one-half of one percent of the bid, the contractor shall be deemed to have agreed to perform such portion, and that the Contractor shall not be permitted to sublet or subcontract that portion of the work, except in cases of public emergency or necessity, and then only after a finding, reduced in writing as a public record of the Awarding Authority, setting forth the facts constituting the emergency or necessity in accordance with the provisions of the Subletting and Subcontracting Fair Practices Act (Section 4100 et seq. of the California Public Contract Code). If no subcontractors are to be employed on the project, enter the word "NONE." SUBCONTRACTORS Type of Work to be Subcontracted Business Name and Address DIR Registration No. License No., Classification & Expiration Date % of Total Contract Total % Subcontracted: _______________ The Contractor must perform no less than 50% of the work with its own forces. DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B 3 31033838 12/31/22 Crane 1000054471Brewer Crane 12570 Hwy 67 Lakeside, CA92040 PWM23-1989FAC Faraday 173 A & B 3 Ton & 5 Ton Page 6 of 25 City Attorney Approved 8/2/2022 Heat Pump Replacements EXHIBIT B Faraday Meeting Room 173 A & B 3 Ton & 5 Ton Split System Heat Pump Replacements Contractor to provide all materials, tools and labor necessary to remove and replace (2) existing HVAC units that serve Meeting Room 173 A & B at the Faraday Center located at 1635 Faraday Ave, Carlsbad, CA 92008. All work and materials to be consistent with the Contractor’s proposal dated September 16, 2022, and is attached to this agreement as Exhibit C. The scope of work shall consist of: JOB QUOTATION ITEM NO. UNIT QTY DESCRIPTION PRICE 1 LS 1 Remove and dispose of exisiting HVAC units and install new 3 ton and 5 ton split system heat pumps (2). Includes crane fee. $23,771 TOTAL* $23,771 *Includes taxes, fees, expenses and all other costs. DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PWM23-1989FAC Faraday 173 A & B 3 Ton & 5 Ton Page 7 of 25 Heat Pump Replacements EXHIBIT C DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B Proposal Date Proposal# HEATING & AIR CONDITIONING 9/1612022 5220 1359 Rocky Point Dr. Phone # Fax# 760-643-1100 760-842-5642 Lie. #790514 Job Location City of Carlsbad Facilities 1635 Faraday Ave 405 Oak Ave Qirlsbad, CA 92008 Carlsbad, CA 92008 AlTN: Facilities Division Rep CB Description Total Conference Room 173 B 23,771.00 Proposal 10 replace (2) exis1ing split system hea, pwnp units with new Carrier M#25HCE436/FB4CNP036 an<l lCP M#R4H460GKP carrier M#FB4CNP060. Scope of work includes condenser coil coating, crane, disposal, labor and tax. Labor $4,760 Materials S 16,862 Tax $1,349 Crane $8,00 PWM23-1989FAC Faraday 173 A & B 3 Ton & 5 Ton Page 8 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B 25HCE4 Comfort..., 14 Heat Pump with Puron® Refrigerant 1-1/2 To 5 Nominal Tons •+@♦ Turn to the exper ts Product Data Comfort· SER I ES Carrier heal pumps with Puron® rcfrigcranl provide a collection of features unmatched by any other family of cqoipmccnt. The 25HCE4 bas been designed utilizing Carrier s non-02one depleting Puron® refrigerant. NO'f£: Ratings con1aincd in this document are sli>ject to change at any time. AJways refer to the AHRI diroctory (www.ahridiroctory.org:) for the m~ up-to-date ratings infonna1ion. Industry leading Features I Benefits Efficiency 14 SEER / 11.0. 11.5 EER /8.2 HSPF • Microtubc Tochnology™ refrigeration system • Indoor air quality accessories available Sound • Sound level as low as ff) d8A • Sound levels as low as 68 d8A with occcssoty sound blanket Comfort • System suppons programmable or standard thcm100.tat controls Reliability Non-ozone depleting Puron® rd iigcrant Scroll oomprcssor Internal pres.sure rd icfvalvc Internal thcnnal overload La;.s of charge switch filter drier Balanc.cd ~mgera1ion system for maximum ~liability Durability WeatherAm10rrw prot«tion package:: Solid, durable sheet metal construction • Dense wire ooil guard • Baked-on powder paint Applications Loog-line • up to 250 feet (76.20 m) totaJ equivalent length. up to 200 feet (60.96 m) condenser above evaporator, or~ to 80 ft. (24.38 m) cva.porator above condenser (S« Longline Guide for mo~ infonnation.) Low ambient cooling: (down to -IOOf/-23.l°C) with accessory kit Faraday 173 A & B 3 Ton & 5 Ton Page 9 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B 25HCEA: PYodud Data Model Number Nomenclature 2 3 4 • • 7 8 • 10 11 12 13 N N A A A/ff N N N ""' A/ff A/ff N N 2 • H C E • 3 • A p 0 3 0 Produel PIOdUCl "" MajOr SEER COOiing G<ile Yatiadon OUldoor Tube -·· Minor ...... Family ser~ capad'ly V8rlati00.S series O-Not Delr'led 0-C.,,pe< 3-208,.2:»1 25 •HP H • RES HP C•°""""' E • Pu'OO 4•14 SEER A.oense Gillie P-Hc>High 5-208/'l30-3 o, 1,2 .•. Pressure SWllch L •Al~UM &-460/3 Puron. WFHiiiii ♦ ,.....,,,._c,,.-n,, __ _ --·-:=::..-:.-=... -F• --q Standard Features Feth.we 18 24 30 .. 42 .. 60 Pu,on Reirigeratlt X X X X X X X SCf011 COmpre9-~ X X X X X X X Field lnstaaed A ter Ofier X X X X X X X Frort Seating servk:e Ya.hies X X X X X X X ln~rnal Pft!!sst.We Rellei Vah'e X X X X X X X ln~mal Thennal OVerto&O X X X X X X X Loog Line eapacmty X X X X X X X LON Ambient COOiing ~ity w1lh Kl X X X X X X X Suctiotl Une ACOJMt.Mtor X X X X X X X LOSS or Olarge SWitcfl X X X X X X X 81111 Sealing Fllil MoCor X X X X X X X Physical Data UNIT SIZE • ~e,s 18-30 I 24-30 I 30-30 I H-31, 51,61 I 42-30 I 48-30. 50. 60 I 60-30 I 60.SC, 60 36t.,30 42L-30 Compressor Type """" REFRIGERANT Puron•(R-410A) Con""' lXV (Puron Hard Sfluloff) OUIOOOf Heata'lg Piston • 42 I 46 I 49 I 57 I 61 I 65 I 78 I 78 Charge lb (kg) 5.30 (2.4) I 5.60{2.5) I 6.40(2.9) I 7.ffl(J.48) I 8.25 (3.74) I 8.68 (3.9'1) I 10.60(4.81) I 10.60 (4.81) CONOFAN F«ward S'Nepl Of Pr<,peler Type, Direct OdW AiClbcha,ge Yerlieal MolOrHP 1112 I 1/10 I 114 I 115 I 1/4 I 114 I 114 I 1/4 MOIOrRPM 1100 I 1100 I 1100 I 1100 I 1100 I 1100 I 800 I 800 CAA 1700 I 2195 I 3365 I 3165 I 3800 I 3365 I 4470 I 4470 VALVE CONNECT. (In. ID) va,o, I 518 I 518 I 3/4 I 314 I 718 I 7/8 I 7/8 I 718 LICJ,lid I 318 REFRIGERANT TUBES (In. 00) Ra~d\lapor I 518 I 518 I 3/4 I 3/4 I 718 I 7/8 I 1-1'8 I 1•1/8 Max Uquid Line I 318 •. Unils 11,e mli:<I ...... h 25 ft (7.6 m) ofl~ length. See \'.if-Linc Sixi'3' illlodC,.,,...li"S C'apxil)' Lou I.Ihle .... be,u 1si'3' <>lbet Si:ile$ ill1od knaths ortillC':CCL Noir. See unit l~lillhli<m lMltUC'riowi (or proper in.tlllbtioo. Faraday 173 A & B 3 Ton & 5 Ton Page 10 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B 25HCE': PYodud Data Vapor Line Sizing and Cooling Capacity Loss Acceptable vapor line diameters pro\'ide adequate oil ~tum to the compressor while avoiding excessive capacity loss. The suction line diamc-tcrs shown in the chan below are aeeepcable for HP systems with IVon ~frigerant: Vapor Lint' Sizing and Cooling Capacity Losi1~ -Pumnr llt'frigcn nt 1-Stagt' Heat Pump Applications A<:c&ptable Cooling capacity LoS9 (%) Total EquivaleN Une Length (ft) Un.it NOfl'linal Size Vapo, Line Standard AppliealiOn Long LiMApplieation ~Nt,.uceuoriH {Bluh) Oiametets (ltL OD) 25 50 80 -... ,,. ... ,,. 200 220 200 (7.62) (15.2) (24.') (U.••> (3U8) (Sl.10) f'l.72) (13.34) (I0.98) (88.08) (l'l.20) 1/2 1 2 3 3 4 6 7 8 9 10 12 18,000 516 0 0 1 1 1 1 2 2 3 3 3 516 0 1 1 1 2 3 3 4 4 5 • 24,000 314 0 0 0 0 0 1 1 1 1 1 2 516 1 2 3 3 3 4 5 • 7 6 • 30.000 314 0 0 1 1 1 1 2 2 2 3 3 716 0 0 0 0 0 1 1 1 1 1 1 516 1 2 4 4 5 6 7 • 10 11 13 38,000 314 0 0 1 1 1 2 2 3 3 4 4 716 0 0 0 0 0 1 1 1 1 2 2 314 0 1 2 2 2 3 4 4 5 6 • 42.000 716 0 0 1 1 1 1 2 2 2 3 3 3/4 0 1 2 2 3 4 5 5 6 7 • 48,000 716 0 0 1 1 1 2 2 2 3 3 4 314 1 2 4 4 5 6 7 • 10 11 12 60.000 716 0 1 2 2 2 3 4 4 5 5 • 1 U8 0 0 0 0 1 1 1 1 1 1 2 S~rd Lcn11.th • 80 fl (14.4 m) « bs IOlill ,:q!Jlr\•aknl le-flslb ApplicllliO(IS ill lh# -II we long line. A«c.'Sll.lrie:c -R<qllffi IIS ~'fl m:ommmdnl Ult Long unc Aff!licalaln Guideline, Applic111i .... s i1t ,his -11111,l.Y tu.,~ height ~i-!Mt limit illk>',\1'bie WIIII equivalml bl!Jh. 1''hm ooldoor i:.til is bc:low indl)OC'tinit Sec Loaig Line Applic.l.1iull Guidd:ines Faraday 173 A & B 3 Ton & 5 Ton Page 11 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B 25HCEA: PYodud Data Refrigerant Piping Length Limitations Maximum Line Lengths: ihe maximum allowable toca.1 equivalent length for he.at pumps varies depending on the ,,'Crtical separation. See the tablC"S below for allowable lengths dependinJ on whether the outdoor unit is on the same lc\'el~ above or below the outdoor unit. Maximum Lin~ Length!! for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTH( MAXIMUM VERTICAL SEPARATION h(m) ft(m) UnilS 01'1 equal le<Yet 200(61) 250(76.2) OU1door tril ABOVE 200 (61) 250(76.2) lndoor t#lit OUldo« t#lil BELOW See Table 'Maxm utn Total Equtnle1"11 l.ef'lglh: OUldoor Unit BELOW hdoor Unit' lr'ldoor t#lit Maximum 'fotal £quiv-.alent Ungth •( -Outdoor Unit BELOW Indoor Unit Liquid Ut!e HP with Puron-Ref1ige,ant • MaXimum Total Equivalent Length Size Oiarne1er ~tk:al Sepe rat.ion ft (m) Outdoot Ul'l.it BELOW indOOI Ul'lie w/TXV 0"20 21-30 31-40 41°50 51-60 (0 ·6.1) (6.4•9.1) (9.4 -12.2) (12.5 • 15.2) {15.5 -18.3) ,a.ooo 318 250" 250" 250" 250" 250" 24,000 318 250" 250" 250" 250" 250" 30~00 318 250" 250" 250" 250" 250• 36,000 318 250" 250" 250" 250" 250• 4 2,000 3lll 250' 250" 250" 250" 250• 48,000 3lll 250" 250" 250" 250" ZlO 60,000 318 250" 225" 190 150 110 •.TO'UII cqui,,de'fll leng1h 11««m1$ r .... bS$C':Cdlle 1odbo-i,-,: «fitting.Sec lhe l.ooc: Linc Gu:idelin.e for dclllib. • OUt"Sidc 11«cptlbk l"llQF Long Line Applications 61-70 (18.6 • 21.3) 250" 250" 250" 250" 250" 160 - ft(m) NIA 200(61) 71410 (21..6· 24..4) 250" 250" 250" 250" 150 -- An application is eonsiderod Long Line when the refrigerant level in the system requires the ~e of acoessorics to maintain acoq,table rd rigerant maoagemeat for systems reliability. Oefming a system as long line depends on the liquid line diameter, actual lccngth of the tubing, and venical separation beh1o-cen the indoor and outdoor units. for Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these, lengths, long line acocssoriC"S are required: Liquid Line Sin 318 NOie: Stt Long Linc Guide,linc fiir dc1.1ik HP with l'umn Rdri1,terant Lon2 Line 0t!!!cription ft (m) lkyond the,;e lengths. long line accei1i1oritll an-n-quin-d Units On Same Level C>utdoor BelOW Indoor 80 (24.4) 20 (6.1) verblor 80 (24.4) total Outdoo, Above lndocr 80 (24.4) Faraday 173 A & B 3 Ton & 5 Ton Page 12 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B 25HCE4: PYodud Data Electrical Data UNITSIZE • OPERVOLTS COMPR FAN MAXFUSET or Vollage, Series \I/PH MAX ... 18 -30 24 •30 ,0.30 36•31 :l&,,O 208-230·1 253 197 42 .30 42L-30 ... ,. ... ,. 36-51 ..... 20812J0.3 253 187 ..... 36•61 ..... ..... 506 414 ..... •. P.-trmiuiblc limi:s ordtc ,'OIUIF nmg,: 111 ,½lid! t11,,: ...,_i1 •i ll o~ limMIIC'.W'ily t. ••TunM):by 6.tlc. flA -Fllll load Amp,: LRA-Lod:NI bi« Amps )lf'.A-Miniml.UI Cirt!lil Amps RLA-RIICN l..olldAmp,: LRA RL.A 48.0 9.00 .... 10.90 12.5 13.50 15.0 15.10 15.0 14.90 105.5 18.10 105.5 16.20 10&0 19.00 144.2 24.40 10.0 8.46 1:23.0 10.44 110.0 15.96 3 1.0 3.85 60.0 6.00 52.0 7.75 SOT£: Control cirtllit is 24.V m di ...,_ib iU1d require,; o:1cm11I p,.M~r $0'UrtC. Copper ...,-if!: mustbcus,:d (nim u,:,,·ic-c disronn.ed o:, uniil. All mo1.-n'C'Ompre,;,11.'lD C'OOWfl iD1-' ov«k>.:id pr,x,e..'bl:ln. Compie:c with requin,m,:ni, of ASHRAE Sum,tmb 90. l A-Weighted Sound Power Without Sound Hood fl.A MCA 0.50 11.8 0.60 14.2 1.40 1"3 1.10 20.0 1.10 19.7 1.40 24.0 1.40 21.7 1.40 25.2 1.52 32.0 1.10 11.7 1.40 .... 1.52 21.5 0.60 5.4 0.77 8.3 0.77 10.5 STANDARD TY-PICAL OCTAVE BAND SPECTRUM (dB, without tone adjUStment) UNIT SIZE,VOLTAGE, SERIES RATING 12-SHz. 250 IU 500Hz 1000 Hz. 2000 Hz 4000 IU (dBA) 18-30 69 . , .. 85 67 59 57 2'-30 78 .. 70 70 70 87 84 30-30 n 71 74 75 73 .. .. 36-31, 51, 61, 36L-30 78 "' 75 75 73 .. 57 42-30, 42L-30 78 70 74 71 71 ., 84 48-30. 50, 60 79 72 78 77 78 70 87 50-30 73 71 74 71 69 .. 61 60-50, 60 78 73 74 72 72 .. 84 !'iOTf.: Tc,u,J m IIC'C'Ord.-.ec .... -.lb AHRJ Stllldml 210.fl« (lll)t 11'1,:d •AIIRJ). A-Weighted Sound Power with Sound Hood STANDARD TYPICAL OCTAVE BAND SPECTRUM (dB, Without tone adjustment) UNIT SIZE,VOL TAGE, SERIES RATING 12-5 Hz. 250 IU SQOHz 1000 Hz 2000 Hz 4000 IU (dBA) 18.,0 68 .. 65 .. 65 .. 56 24.,0 74 87 70 70 58 66 81 30-30 n 72 74 75 72 69 .. 36-31, 51, 61, 3&.-30 78 78 78 78 73 69 65 42-30, 42L-30 74 71 74 70 70 ., '"' 48-30, 50, 60 79 73 79 n 75 70 87 60-30 73 72 75 70 88 53 60 60•50, 60 76 72 72 71 72 .. .. CKTBRK -· 20 25 ,. ,. ,. 40 ,. 40 50 20 25 ,. 15 15 15 8000Hz 54 55 81 82 58 81 58 83 8000 Hz 52 .. 60 60 56 81 55 83 Faraday 173 A & B 3 Ton & 5 Ton Page 13 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B 25HCE4: PYodud Data Charging Subcoollng (TXV-Type Expansion Device) UNJTSIZE,VOLTAGE REQUIRED SUBCOOUNG ·Frc, , .. ,. 11 (6.1) , .. ,. 11(6.1) ,0.,0 10(5.6) 36-31, 36L-30 10(5.6) 36-51,61 11(6.1) 42-30 10(5.6) 42l.,30 11(6.1) 48-30, !10, 60 14 (7.8) 60-30, !10, 60 15(8.3) HP Only Replacement with Piston Indoors When the 25HCE4 is ~od as a rq,lacemcat componen1 in a system with a pi~on fan coi~ use the indoor pi~on size spoc-ified below: UNIT SIZE PISTONSIZE f 8'CNF ffM FPMA ,. 0.052 0.050 0.050 24 0.057 0.057 0.058 30 0.067 0.070 0.067 38 0.070 0.072 0.069 ., 0.078 •• 0.084 60 •NIA Faraday 173 A & B 3 Ton & 5 Ton Page 14 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B Dimensions If U ... sr,) ;:$ W .u,) t m• IU.l) .. ----JU,14 ..,_. I .. N:ZSJ;< ~.f ZW -·• t PJ14 1tl.l)Jl t;,, 5'11.-'t \'t lf)IJ'1'1l'IU»-.W11tJI ··1$-1 )011, .. __,tW t;' ll:111'1 1W.J ••vlll l'lll.7 .... -• ,_, _ __, llW If )I J'1'1 l'IU ~ , ... ,_. ll-1$ -• )U-__, t W >-----Av.-----< 11•0l$(Mt(.t / ~C1~w(Utll ~Yso~ ,u,w 1-----Xso-----l ic~-. ... -------------------17 718 454.8 20 7118 518.5 I ,W;> G 11,11,· Ill 01 :11 :1116 7!1.2.S 22 15,!18 SB:1.2 '.IS SM.O 2& '1.'-4 879,7 NOTE: ALL DIMENSIONS IN INCH {MM) NO'TES. 1. CENTER OF ORA.Vl1V ~ • 1--· )WCth ~> IUOOII\ O()(KCIJ"S 1t)Pt.l((S U.S. ECCN: NOi Subjecl to Regulation (N.S.R.) -I.A:IIGlll/MOtN ... W.O U•~'tfo •t.• 1/0.0 .. Ii. IUf.J Faraday 173 A & B 3 Ton & 5 Ton Page 15 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B Wall 6" (152.4 mm) 24" (609.6) Service 12" (304.8) 24" (609.6) Service 18" (457.2) Note: Numbers in () = mm Allow 48-" above unit 12" (304.8) 18" (457.2) Clearances Clearances (various examples) Wall 24" Service 12" 6" ~ (304.8) (152.4) 12" (304.8) Wall 24" 24" (609.6) (609.6) Service Service 18" (457.2) JM POi:rl'AN·r: When installing multiple units in an ako\'e. roof well or partiaJly enclosed area. ensure there is adequate ventilation to prevent re•circulation of discharge air. ~ ~ ~ ~ Faraday 173 A & B 3 Ton & 5 Ton Page 16 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R-410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz REFRIGERATION CIRCUIT • Scron compressors on au models • Suction line accumulator factory installed • Integrated solid state control with Time-Temperature Defrost • Low pressure switch • Copper tube / aluminum fin coil EASY TO INSTALL AND SERVICE • Easy Access service valves on all models • External high and low refrigerant service ports • Only two screws to access control panel • Factory charged with R-410A refrigerant BUILT TO LAST • Painted cabinet finish over galvanized steel • Models available with coated inlet grille with 2· (51mm) spacing and with 3/8" (10mm) grille spacing for extra protection LIMITED WARRANTY' • 5 year parts limited warranty (including compressor and coil) c@us LISTED A.,--=~= CERTIFIED , ... , ' . UH ol ,-Nfto.rtillMI TM Mlll'l(lrdc-- fllfffl!l'lll'llll'ol::urtftipir:Ul;~ btlt prog,arn. For ~ ot °"1111catlon tor tdYltlJfll p,odud!I, go '° ~IOt)'.otg. -With timely registration, an additional 5 year parts limited warranty Qncluding compressor and coil) * For residential applications only. See warranty certificate for complete details and restrictions, including warranty coverage for other applications. Model Size Nominal Min. Clrcuh Max. Fuse operating 01mens1ons Operating/Ship Weight Number (tons) Btu/hr Ampaclty or Br•aker length x width x height lbs, (kg) Inches (mm) R4H418GKP t½ 18,000 11.8 20 23-1/8 X 23-1/8 X 35-1/16 136/ 166 (587 X 587 X 891) (61 / 75) R4H424GKP 2 24,000 14.2 25 25-3/4 X 25-3/4 X 35-t/2 144 / 175 (654 X 654 X 901) (65/ 79) R4H430GKP 2½ 30,000 18,3 30 31-3/16 X 31-3/16 X 31-11/16 158/ 180 (792 X 792 X 804) (72 /82) R4H438GKP 3 36,000 20,0 30 31-3/16 X 31-3/t 6 X 28-t/4 170/201 (792 X 792 X 718) (77/91) R4H442GKP 3½ 42,000 24,0 40 31-3/16 X 31-3/16 X 38-7/16 201 / 235 (792 X 792 X 977) (91 / 107) R4H448GKP 4 48,000 25,2 40 31-3/16 X 31-3/16 X 28-t/4 t97 / 232 (792 X 792 X 718) (89 / 105) R4H449GKP 4 48,000 31.8 45 35 X 35 X 32-1/16 238/262 (889 X 889 X 815) (108 / 119) R4H480GKP 5 80,000 32,0 50 31-3/16 X 31-3/16 X 31-t t/t 6 212 / 248 (792 X 792 X 804) (96/113) Faraday 173 A & B 3 Ton & 5 Ton Page 17 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PRODUCT SPECIFICATIONS Split System Hut Pump: R4H4 OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDE (slngl• phas•) Dig~ Position: 1 2 3 4 5,6 7 8 9 10 11 12 Example Part Number: R 4 H 4 18 G K p 1 0 0 4 = R-410A REFRIGERANT A = Air Conditioner H : Heat Pump TYPE 4 : 14 SEER NOMINAL EFFICIENCY 18 = 18,000 BTUH = 1-1/2 '.ons 24 = 24,000 BTUH = 2 tons 30 = 30,000 BTUH = 2-1/2 '.ons 36 = 36,000 BTUH = 3 tons 42 = 42,000 BTUH = 3-1/2 '.ons 48 = 48,000 BTUH = 4 tons 49 = 48,000 BTUH = 4 tons 60 = 60,000 BTUH = 5 tons NOMINAL CAPACITY G = Coil Guard Grille, 3/8" (10mm) spacing FEATURES K = 208/230-1-60 VOLTAGE Sales Code (P = no HPS) Engineering Revision Extra Dig~ Extra Dia~ ACCESSORIES PART NUMBER IDENTIFICATION GUIDE Digit Position: I 1 2 3 4 5 6, 7 8,9 10, 11 Example Part Number: I N A s A 0 0 1 01 CH N = Non-Branded BRANDING A = Accessory PRODUCT GROUP S = Spl~ System (AC & HP) KIT USAGE A = Original B = 2nd Generation MAJOR SERIES O = Generic or Not Applicab!e 4 = R-410A REFRIGERANT Product Identifier Number Pacf<age Quantity Type of Kit (Example: CH = Crankcase Heater) Faraday 173 A & B 3 Ton & 5 Ton Page 18 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PHYSICAL DATA UNIT SIZE 18 I 24 I :ro I 36 I 42 I 48 I 49 I Celfflorestot" • """'' REFRIGERANT R-410A con1r01 TXV (R-41°" Han:! Sl'lulOffJ Outdoor Heati'la F'iSlon II 42 I .. I 49 I 57 I ., I .. I lXV I Charge lb ncm S.3(2.4) I 5.8 (2.S) I 8.4 (2.9) I 781C3.48) I 8.25(3.74) I &.68(3.941 I 9.87C4.48) I CONOFAN Fc:itw&d Sw o, '"'' , Oi'ed Orl11e Air OiSCharae V"1ieal '"" I I ,,. I ·~ I "4 I "4 I ... . ' ' ' . ' ' ' ' ' VALVE CONN.ECT. (In. 1.m ' I 518 I 518 I 3/4 I 3/4 I 718 I 718 Uouid I 3/8 REFRIGERANT 1\18£S• lift. oo, Ratec!Vapor I 518 I 518 I 3/4 I 3/4 I 718 I 718 Maxltluidt..ie I 3/8 "O'lits are t8ted wittl 25 ft (7 .8 tn) Of lineset ler'lglh. see V8,00f" UM Sizing Md Coo.li1g Otpaeily Lou t8llle wt'leri uisi'lg olhet sire,s and le-tlglhS or ftle-:set Note: see I.Wlil ltlMali!lliOtl ltlMr1.cliOtl IOr propeit i'lstellatior'I. ELECTRICAL DATA OPERVOLTS• COMPR FAN UNIT SIZE V/PH MAX MIN LRA RLA FLA 18 48.0 9.0 0.50 24 62.9 10.9 0.60 30 72.S 13.S 1.40 .. 206/230/1 253 197 75.0 15.1 1.10 "2 106.5 18.1 1.40 .. 108.0 19.0 1.40 49 130.0 24.4 1.30 60 144.2 24.4 1.52 . PenriS:9ible li'ritS ol ltle w ltage rMge at wt'liCh the unit wi11 eperete satistaeleriy Tll'Yle-Dell!ty luse. FU. -Ful Load Amps LRA -Locked Rok>r Amps MCA -Minitru'YI Cireuill /l,,lrfJ$ AU. -Rated Load Atr'i,1$ NOTE~ COnltOI Circuit il 24-V 0t1 all U'lits 8ild requirM eJ11.1e«1ef powe, source. OOpper wire MUSI be used ton, service diS00tll'led IJO ul'lil. Al MOIOr~e-ss0t'$C0tlt&il'I inler"l'lef ~IOed p,oleetion. COMples wilh 2007 tequireMeills <:A ASHRAE Stanclards90.1 A-WEIGHTED SOUND POWER MCA 11.8 14.2 •8.3 20.0 24.0 25.2 31.8 32.0 I ' ' I I UH.IT SIZE RAYi.NG TYPICAL OCTAVE BAND SPECTRUM (dBA. WithOlul tone ad;.tstment) (dBAl 125 250 500 1000 2000 4000 18 89 45 .. 58 62 55 53 .. 70 40 .. .. 83 03 00 30 n 52 62 87 .. .. 82 .. 77 51 62 .. .. .. 01 42 78 49 81 83 05 .. 00 .. 79 53 .. .. 71 87 .. 49 73 87.5 87.8 70.1 70.8 83.1 58.5 60 73 50 83 62 83 00 58 NOTE~ Tested in accotdel'lce wilh AHRI Stel'lderd 270-08 (nol lS'ted SI AHAJ). A-WEIGHTED SOUND POWER WITH SOUND HOOD UH.IT SIZE TYPICAL OCTAVE BAND SPECTRUM d WithOlul tone ad,ustment RAYi.NG 125 250 500 1000 2000 4000 18 88 47 .. 58 81 .. 52 24 74 47 57 .. 62 ., 58 30 77 52 62 87 87 .. 02 .. 78 52 62 88 87 .. 00 42 74 50 01 83 .. ., 58 .. 79 54 88 .. 10 87 .. 49 71 .... 87.7 09.7 87.0 .... 56.4 80 73 51 .. 62 83 59 58 NOTE~ Tested in accotdel'lce wilh AHRI Stel'lderd 270-08 (not IS'ted SI AHAJ). CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) -.. 11 lQ.II 24 11 (6.11 30 10 (5.til 38 10 (5.6) 42 10 (5.til 48 14 (7JI •• 9 5 .01 •• lb l l"l.;<11 60 78 10.6 (4.81) .,, 718 1-1/8 MAX FUSE•• or CKT BRIC AMPS 20 25 30 30 40 40 45 50 8000 47 55 55 53 52 57 53.3 52 8000 48 51 54 52 49 58 50.0 49 Faraday 173 A & B 3 Ton & 5 Ton Page 19 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PRODUCT SPECIFICATIONS Split System Heat Pump: R4H4 HP ONLY REPLACEMENT WITH PilSTON INDOORS When the R4H4 ls used as a replacement component in a system with a piston fan coll, use the lndooc piston size specified below: UNIT SIZE PISTOf<I SIZE FEM4P FMA4 FM(C,U)41? ,. 0.052 0.060 0.050 24 0.057 0.067 0.056 30 0.087 0.070 0.087 38 0.070 0.072 0.069 42 0.078 .. 0.084 •• 0.084 80 VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acoeptable vapoc Une d18.meters provide adequate oil return to the compressor while avoiding excessive capacity loss. TOO suction line dlametetS shown In the chart below are acceptable for HP systems with R-410A refrlg,erant: Vapor Un• Slzfng and Cooling Ca.paclty Losses -R-410A Refrigerant 1-Stage H1at Pump Appllc.atlons COOiing CapaeJty LOH (%) Unit H<Wninal Site Aoceptable Vapor Total EquiValent Lint L~gth (ft) (Siuhl Lint Diameters SIIWIClard AppliGelkln (In.OD) 25 50 80 -1• 18 1• 171 ---(7.62) (15.2) (24.4) _, -(a111 .... .,., ....... -111-111 -10000 1/2 1 2 3 • • 7 I • 10 12 1-SlageHP 518 0 0 1 1 • 2 • • • 24000 518 0 1 1 1 • • • • • 1-SlageHP 3/4 0 0 0 • 1 1 1 1 • 518 1 2 3 • • • 7 I • 30000 3/4 0 0 1 • 2 • • • 1-SlageHP 1 7/8 0 0 0 • 1 1 1 1 1 518 1 2 4 • 7 • 10 11 ,. >8000 3/4 0 0 1 • • • • • 1-SlageHP 1 7/8 0 0 0 • 1 1 1 2 • <2000 3/4 0 1 2 • 4 • 5 • • 1-SlageHP 7/8 0 0 1 1 2 2 2 3 3 ¢8000 3/4 0 1 2 • 5 • • 7 8 1-SlageHP 7/8 0 0 1 1 2 2 3 3 4 49000 3/4 0 1 2 • 5 • 8 7 8 1-S19teHP 1/8 0 0 1 1 2 2 3 3 4 3/4 1 2 4 4 7 • 10 ,, 12 80000 7/8 0 2 2 2 3 4 • 5 • 8 1-Stage A-410AHP 1 11/8 0 0 0 0 1 1 1 1 1 1 2 S11W"dard Lenglh = 80 l'I. (24.4 m) Or less 10181 ~ler'lt ler'IQlh ~ in lhis aree May have heigh! restndiOr'ls lhal liMil allowatll! IOlal equi\tatel"ll lenglh, -'!en oUldool' ._.,.l is bebw indoor ur'lit see l.Otlg line ~atiOf"I Gi.ade- lines REFRI GERANT PIPING LENGTH LI MITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable l'engths depending oo whether the outdoor unit Is on the same level, above o r below the outdoor unit Maximum Un• Lengths for Heat Pump Appllcatlons MAXIMUM ACTIJA.L LENGTH MAXIMUM EOUIVALENT LENGTK1' MAXIMUM VERTICAL ft lml ft(m) SEPARATION fl! (m) Ur'it!I 01'1 equal level 200 (61) 250 (76.2} N/A Oi.J1d00i i.i'Jl ABOVE 200 (81) 250 (76.2} 200 (81) ~rur'lil OIJldoo.r ur'il BELOW see Table 'M8Xl·mum Totllf EQI.WS~t ~: CMt:loor Umt BELOW htdoor Umt' i'd>or ur'lil t Total equivalMl IH!gth accounts fOI' k>HeS due to elbow$ o, fitting. Sff the Long Une Guickline fOC' details. Faraday 173 A & B 3 Ton & 5 Ton Page 20 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PRODUCT SPECIFICATIONS Spilt System Heat Pump: R4H4 Maximum Total Equivalent Lengtht -Outdoor Unit BELOW Indoor Unh Liquid ~ HP Wilt! R-t10A Atfiigeranl -UUifflUl'l'l TMII Etiuivaatftl Ltngtflt -Diameter Vertical Separation ft (m) outdoor lril BELOW indool" unit; (Witt! R-4tOA) 0-20 21-30 31-40 41-50 51-80 81-70 71-80 w/TXV co-6.1) (8.4-9.1) (9.4 -12..2) (12.15 -15..2) (115.15 -1 &.3) (1&.8-21.3) (21.fl-24.4) 18000HP 3/8 250• 250• 250• 250" 250" 24000HP 3/8 250• 250• 250• 250" 250" 30000HP 3/8 250• 250• 250• 250" 250" 36000HP 3/8 250• 250• 250• 250" 250" 42000HP 3/8 250• 250• 250• 250" 250" 48000HP 3/8 250• 250• 250• 250" 230 49000HP 3/8 250• 250• 250• 250" 230 60000HP 3/8 250• 225• 190 150 110 • MaDnum actual hngttl not to e)(ceed 200 rt {81 m) t Total equlvalMl hngth accounts fo, k>Hes due to elbows o, fitting. Sff the Long Une Guichline fo, details. -■ Ot.ltside aee&p&able range LONG LINE APPLICATIONS 250• 250• 250• 250• 250• 250• 250• 250• 250• 150 160 -- 160 ---- -- An appl!catlon Is considered Long Line when the refrigerant level In the system requires the use of accessoties to maintain acoeptable refrigetant management for systems rellabillty. Defining a system as long line depends on the liquid line diameter, actual length of the tubing. and vertical separation between the Indoor and outdoor units_ For Heat Pump systems, the chart below shows when an application Is considered Long Line. Beyond these lengths, long line accessories are required: HP WITH R-410A REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond the-H lengths, long ltne accessories are required .d Lint Size Unls On same Level OUtdoot" Above ln,ct,o,cw 3/8 80 24.4 20 Note: See l.Or'lg Li'le Guidelr1e IOr details High Temp lndool" COil Model Cooling Model Size EER SEER HSPF Number Capaeity E Capacity ECOP ,. FEM4X18 .. BL 17,800 11.S 14 17,600 2.72 24 FEM4X30 .. BL 22,200 11.S 14 22,200 2.84 30 FEM4X30 .. BL 2!-600 11.S 14 28,600 2.62 38 FEM4X3S-.. BL 33J)OO 11.S 14 33,800 2.62 42 FEM4X42' .. BL 40J)OO 11.S 14 41.000 2.62 48 FEM4X48 .. BL "'°°" 11.S 14 45,500 2.64 •• FXM4X60 .. AL "'°°" 11.S 14 46,500 2.64 .. FXM4X60 .. AL 57.000 11.S 14 54,500 2.70 t A • &IIM•d Grille, G • Coil Gwrd Grae • AHAi • Nt COr'ldiliOl'ling.. Heetil'lg & Re-trigeretiol'I Ntitute • Rafl'lg9 are t1et Y&lue-s relleetil'lg the e-tleet9 of Cirwlali'lg 1M heel Supptemerit:al eleelie heel is l'IOI i'lclucled. Ratings are based 0t1e COOiing Standard: 80"F (27•C) GI> 87°F (19°q wt, inclOOt' er'llt!t'itlg air letri)el'8tureatld 954 F (354C) db air et11t!ti'19 OUUIOOr uril. &2 &2 &2 &2 &2 &2 &2 &2 High-Temp He<ating Standard: 70"'F (21 •q GI> i'ldoor eriterl~ air remperature 8ild 47"F ta•q db 43~ F (6•C) wb air enterir19ould00r unil. Low• Te,np He~ Standard: 70°F (21•q db i'ldOOr entering air ~perall#e and 17°F (-S•C) db 154F (-9°q wt, air etitieri'lg OutlOOt' ul'liL COP -eoe-tlieietlt Of PerlOM"l8r'ICe EER -Energy Eftieiel'lcy RatiO HSPF -Heeling SNsol'lel Pel10m'lanoe FaelOt SEER -Seaso!'lal El'letgy Effiderq, Ra!iO 80 4.4 LowT~ H HCOP Capacity 10,400 2.40 13,200 2.54 17,100 2.44 20,800 2.40 25,200 2.44 27,800 2.56 29,800 2.56 336000 2.56 TESTED AHRI COMBINATION RATINGS• Or scan this QR code: NOTE: Ratings contained In th.ls document are subject to ch.ange at any time. For AHAi ratings certificates. please refet to the AHRI directory. www.ahrldlr.ctory.org Additional ratings and system combinations can be acoessed via the Marathenn database: htfp·J/www icpeqp oom/AHBlreUngs/ratings asnx1 Arand-Meratherm Faraday 173 A & B 3 Ton & 5 Ton Page 21 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PRODUCT SPECFICATIONS SplN Syst8m HHI Pump: R4H4 i i i .. . i i i ; i i .. •· i i I i i •• ~ :i • ' ' ' ! ~ ~ ! ' ' ' •· -:: :: . . ' ' . . • t i! i .. . . . . . . . . . . . ii ii i i i • i i 1•, ,!, ' ' ' ' • • • • • • • • • • • • • • • • • • • • • • • • l 2 i i • .. . . ! i i :l: ,. ' i ; i ' : : Ii •• ! ! ! ~ ! ! i ii I I I ! ! • l i ! ; i i ~ i ' ' ; ; i i ,. •• ,, ! ! ! ! ! ' ! ! i i ! ! ' ' i i ii i n . : . • tli i I I i E : : : : ' ' ' : : ' ' ' •• 5 :: :: ••• . ~ i i • ; i ii i : ! ! ! : : (lj I ~ ~ ' ' ' ' : : : .. : : : : : --' ' . • • • i i i i ; i ii i : ! ! ! : : • i « "' ~ ¥ " C ~ 0 § a, ~ i§ • " .;;; g :.o !!; i l! "' • 0 • ~ ~ ~ ' ' ' ' ' ' ' - -' ' ' ' ' . ' •• • • • i i i ii ii i i i i i i i ~ I i n i i i i ii i i i ii . . . . . . . . . . . . . . ' i i ii ii i ; ' ' ' ; i • ' ' ' ' ' ' ' ! ! ' ' ' ' ' - -- - - - - -- - - - - -; . . • • • • •• • • • . . ' i ii ii i i i i i i i ; . . ' ' ' ' ! ! ' ' ' ' ' = ; . . . . . . . . . . . l " ! §S ~ " ~~ - cl: % 2 0 ., iii •--K ~ I Ii • ii iii i i i i i I ! ! : : i i i i i i i i i i ' ' - - ,. ,. ,. ,. ! !! ! i i i i i i i i i ! • . . • • • • • • I • • • • . . ' .. . . . . . . . . ----. . . . . . . . . . l l: . -•• -. l l l .. • • • • • • ' ' . • ' ' ' ' ' ' ' ' ' ' i ii ii i ! ! 5 i . . i i ! ! ' ~ !' !' ! ! ' ? :a' ' ' ' - -- -• • - i .. • • ii i ; I I I ; i I • • I ' ' ' ' • • • • • • • • • • •e • ••• • • • • • • • • • • :, ,: . . . . . . . . . . . . . . •11, . . . . . . . . . . . . . . ··-if . . . . . . . . . . . . . ·--. . . . . . . . . . . . . . ·--I - -- - - - - -- - - - - - • ' . ! I 'I ii Ii ' . ' i i' r i i a II I l l d Ii :!: ~ == I!! TI j "' • • • .. >-K / Jl .-'! i ! i~!i ~! i§ l, ig~i i; :! ! ~11 ;! ! !j ~ =~~;: :? •-"" !~ 11 fi.; l • ~ $ ~ ' --Ji:; ~· g?;~§ n $ • • ~ , 6 428 65 6008 07 Faraday 173 A & B 3 Ton & 5 Ton Page 22 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B ' I - Product Data At0082 AIR HANDLER TF.cHNOLOGY AT ITS FINEST The FB4C fan coil has the proven coohnology of Ct.rrier fan coil units with Puron® refrigerant as well as vercical and horizontal applicalions. The design fe.;uures contoured condensate pans wilh rugged drain connections, ensuring !hat liule water is lefc in the unit at the end of the cooling duly eye.le. The lack of scanding oondensa1e and corrosion free pans improves IAQ and product life, features homeowners appreciate .. Srandard features illclude gtooved 1u)ing and louvered fills. Coil c.ircuiting has also been updated to 11iake the most of all Carrier he.at pumps and air conditioners. Units come with solid state fan co,nrols, 1 • inch (25mm) thick insu'.ation with R· value of 4.2, muhi•speed motors, and fully•\l'ettable coils. Units can accommoda1e factory• and/or rield• i1stalled heaters from 3 to 30 kW. II also should be no1ed thal the design of these fan ooils meet cabinet air leakage of less tl1an 2% at 0.5 inches W.C., and cabinet aif leakage les.s than 1.4% at 0.5 inches W.C. ,vhen tesced in accordance with ASHRAE 193 standird. The FB4C fan coil design is loaded with populaf features. These ran coils uliliz.e the la1esl in electroni<' commumion moior (EClvt) technology through the use of high efficiency, multi• 1ap ECM moiors allowing reliable aif deli"ery with increased static pressure. II oomes in a pre•painced (taupe ineullic) galvanized steel casing and a fac:1ory• supplied powef plug ror ease of installalion. The FB4C unit is shipped with a rac1ofy• installed Teflon• ring piston FB4CNF(018-048) or a Puron refrigerant TXV FB4CNP (018-061). Faraday 173 A & B 3 Ton & 5 Ton Page 23 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B Product F = Fan Coil Type B = Base, Puron Position 4 = Multipoise Series C Electrical N = 208/230v, 1 ph, 60 Hz Cabinet Style F = Single P1iece with piston P=TXV ~ Priron MODEL NUMBER NOMENCIATURE 2 3 4 5 & 7 8 9 10 11 12 F B4CNF 0 8 0 00 t&HHiifri u..o .......... c.... n,a--· --•N ....... -., ___ -.. -- Heating Size 00 = No Heat 05 = 5kW 75 = 7.5 kW 08 = 8kW 10 = 10kW 11 =11kW 15 = 15kW Coil Type 0 = Copper T = Tin• plate L = Aluminum Capacity 018 = 18,000 024 = 24,000 025 = 24,000 030 = 30,000 036 = 36,000 042 = 42,000 048 = 48,000 060 = 60,000 061 = 60,000 II IS09001 °"'""''- c@us Armor Tech· Faraday 173 A & B 3 Ton & 5 Ton Page 24 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B .......• II" •.•..•..•....... ,_., •. II tJlllllU 1ltl.llJIIH ........................................... 11,. ••••••••••••••••••••••••••••• ,_,, •••••••••••••••••••• lliN 111!1,0lW ____ ,, __ _ • I' ;;;;s=====1 ... I!!!!!!~!!~I :> :> = = = = = ~ ::r -~~~~~~~~~ :n r::::::::::::::::::.::;i DIMENSIONS h111Jf8J SI.JIYIO U M "' nm ., .. Faraday 173 A & B 3 Ton & 5 Ton Page 25 of 25 Heat Pump Replacements EXHIBIT C (Continued) DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B PHYSICAL DATA NOMINAL COOLING OIMENStONS SHIPPIN G ORDERING NO. CAPACITY (B1Uh} Height Width Deptt> WEIGHT FB4CN{f,P)OISL 18,000 42• 11/16in. 14• 5116 in. 22· 1/16 in. 112 lb 1064nvn 363mm 560mm 51 kg FB4CNF024L 24,000 42• 11/16in. 14• 5{16in. 22· 1/16 in. 112 lb 1064nvn 363mm 560mm 51 kg F84CNP025L 24,000 49. 5/8W'I.. 17• 5/8in. 22· 1/16 in. 122 lb 1200nvn 447mm 560mm 55 kg FB4CN(F,P)030L 30.000 49. 5/8W'I.. 17• 5/8in. 22· 1/16 in. 122 lb 1200nvn 447mm 560mm 55 kg FB4CN(F,P)036L 36.000 49. 5/8W'I.. 17• 5/8in. 22· 1/16 in. 122 lb 1200nvn 447mm 560mm 55 kg FB4CN(F,P)0.2L 42.000 49-S/8W'I.. 21· 1/8in. 22· 1/16 in. 15'1 lb 1200nvn 536mm 560mm 71 kg FB4CN(F,P)O.SL 48.000 49-S/8W'I.. 21· 1/8in. 22· 1/16 in. 157 lb 1200nvn 536mm 560mm 71 kg F84CNP060l 60.000 53. 7/16 in1. 21· 1/8in. 22· 1/16 in. 175 1b 1357mn 536mm 560mm '19 kg F84CNP061L 60.000 59. 3/16 in1. 24• 11/16W'I. 22· 1/16 in. 201 lb 1503nvn 447mm 560mm 91 kg SPECIFICATIONS FB4C I IS I 24 25 I 30 I 30 I 42 •• I .. I 01 EVAPORATOR COIL Face Area (sq. ft) 2.23 2.97 I 2.97 4.45 I 5.93 I 7,42 Configuration Slope A F84CNF MetE!'mg De-Jice EA52PT049 EAS2PTOS5 NJA EA52PT()61 EA52PT087 EAS2PT076 EA52PT080 NJA NJA (Teflon• ring pislon) Puron Refrigerant F84CNP MeteJW'lg Oe-Jice TXV TXV TXV TXV TXV TXV TXV TXV TXV Puron Refrigerant FILTER• 21 • 1/2· in 13 · in 16 · 3/8· in 16· 3/8· in 19· 7f8• in rc!· 5116· in (546mm) X (330mm) (417 mn) (417 mn) (!()Snvn) 585 mm) BLOWER ASSEMBLY Motor Type (ECM) Multi• ta,p ECM Motor HP 1/3 I 1/3 1/3 I 1/3 I 1/2 I 1/2 3/4 I 31• I 31• CFM 800 800 800 1000 1200 1400 1800 1750 2000 *Fitter must be fieJd • supplied lor FB4C unrts. CERTIFICATE HOLDER © 1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25 (2010/05) AUTHORIZED REPRESENTATIVE CANCELLATION DATE (MM/DD/YYYY)CERTIFICATE OF LIABILITY INSURANCE LOCJECTPRO-POLICY GEN'L AGGREGATE LIMIT APPLIES PER: OCCURCLAIMS-MADE COMMERCIAL GENERAL LIABILITY GENERAL LIABILITY PREMISES (Ea occurrence)$DAMAGE TO RENTED EACH OCCURRENCE $ MED EXP (Any one person) $ PERSONAL & ADV INJURY $ GENERAL AGGREGATE $ PRODUCTS - COMP/OP AGG $ $RETENTIONDED CLAIMS-MADE OCCUR $ AGGREGATE $ EACH OCCURRENCE $ UMBRELLA LIAB EXCESS LIAB DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is required) INSRLTR TYPE OF INSURANCE POLICY NUMBER POLICY EFF(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)LIMITS WC STATU-TORY LIMITS OTH-ER E.L. EACH ACCIDENT E.L. DISEASE - EA EMPLOYEE E.L. DISEASE - POLICY LIMIT $ $ $ ANY PROPRIETOR/PARTNER/EXECUTIVE If yes, describe underDESCRIPTION OF OPERATIONS below (Mandatory in NH)OFFICER/MEMBER EXCLUDED? WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N AUTOMOBILE LIABILITY ANY AUTO ALL OWNED SCHEDULED HIRED AUTOS NON-OWNEDAUTOSAUTOS AUTOS COMBINED SINGLE LIMIT BODILY INJURY (Per person) BODILY INJURY (Per accident) PROPERTY DAMAGE $ $ $ $ THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THISCERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL WVD SUBR N / A $ $ (Ea accident) (Per accident) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). The ACORD name and logo are registered marks of ACORD COVERAGES CERTIFICATE NUMBER:REVISION NUMBER: INSURED PHONE(A/C, No, Ext): PRODUCER ADDRESS:E-MAIL FAX(A/C, No): CONTACTNAME: NAIC # INSURER A : INSURER B : INSURER C : INSURER D : INSURER E : INSURER F : INSURER(S) AFFORDING COVERAGE SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Burnham WGB Insurance SolutionsCA Insurance License 0F6977115901 Red Hill AvenueTustin CA 92780 Bobbie Mace 714-824-8373 714-573-1770 BMace@wgbib.com Middlesex Insurance Company 23434 SEASI-1 Insurance Company of the West 27847Seaside Heating & Air Conditioning, Inc.1359 Rocky Point Dr.Oceanside CA 92056-5864 659813129 A X 1,000,000 100,000 X 1,000,000 3,000,000 2,000,000 A0112596004 9/18/2022 9/18/2023YY 5,000 A 1,000,000 X X X X Comp $500Ded X Coll $500Ded A0112596001 9/18/2022YY 9/18/2023 A X X 5,000,000 X 5,000,000 NIL A0112596005 9/18/2022 9/18/2023YY B Y WSD502592008 3/1/2022 3/1/2023 1,000,000 1,000,000 1,000,000 9/7/2022 X City of Carlsbad/CMWD, its officers, officials, employees, agents and volunteers are named as additional insured on the General Liability per attached CG 2010 04 13 and CG 20 37 04 13 as required by written contract subject to the terms and conditions of the policy. Waiver of Subrogation applies to the Workers'Compensation per attached WC 99 06 34. City of Carlsbad/CMWDAttn: Contract Administration1635 Faraday AvenueCarlsbad CA 92008 DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B ACORD® I ~ I ~ ~ D □ ~ ~ n n n ~ ~ ~ ~ ~ ~ ~ ~ H I I I I I □ ~ -I I © Insurance Services Office, Inc., 2012 POLICY NUMBER:COMMERCIAL GENERAL LIABILITY CG 20 37 04 13 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - OWNERS, LESSEES OR CONTRACTORS - COMPLETED OPERATIONS This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART SCHEDULE Name Of Additional Insured Person(s) Or Organization(s) Location And Description Of Completed Operations Any person or organization you are required to add as an additional insured under a written contract or agreement in effect prior to any accident, injury, loss or damage All locations and jobs performed that have a written contract, agreement or permit Information required to complete this Schedule, if not shown above, will be shown in the Declarations. A.Section II - Who Is An Insured is amended to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury" or "property damage" caused, in whole or in part, by "your work" at the location designated and described in the Schedule of this endorsement performed for that additional insured and included in the "products-completed operations hazard". However: 1.The insurance afforded to such additional insured only applies to the extent permitted by law; and 2.If coverage provided to the additional insured is required by a contract or agreement, the insurance afforded to such additional insured will not be broader than that which you are required by the contract or agreement to provide for such additional insured. B.With respect to the insurance afforded to these additional insureds, the following is added to Section III - Limits Of Insurance: If coverage provided to the additional insured is required by a contract or agreement, the most we will pay on behalf of the additional insured is the amount of insurance: 1.Required by the contract or agreement; or 2.Available under the applicable Limits of Insurance shown in the Declarations; whichever is less. This endorsement shall not increase the applicable Limits of Insurance shown in the Declarations. A0112596004 Page 1 of 1CG 20 37 04 13 08/27/2021A0112596 Middlesex 00001 0000000000 21239 0 N1 516336ea-c79d-45f3-a59f-97b4065b9ef0516336ea-c79d-45f3-a59f-97b4065b9ef0 DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B Page 1 of 2CG 20 10 04 13 08/27/2021A0112596 Middlesex POLICY NUMBER: © Insurance Services Office, Inc., 2012 COMMERCIAL GENERAL LIABILITY CG 20 10 04 13 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - OWNERS, LESSEES OR CONTRACTORS - SCHEDULED PERSON OR ORGANIZATION This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART SCHEDULE Name Of Additional Insured Person(s) Or Organization(s)Location(s) Of Covered Operations Any person or organization you are required to add as an additional insured under a written contract or agreement in effect prior to any accident, injury, loss or damage All locations per written contract, agreement or permit Description: All jobs performed that have a written contract, agreement or permit Information required to complete this Schedule, if not shown above, will be shown in the Declarations. A.Section II - Who Is An Insured is amended to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury", "property damage" or "personal and advertising injury" caused, in whole or in part, by: 1.Your acts or omissions; or 2.The acts or omissions of those acting on your behalf; in the performance of your ongoing operations for the additional insured(s) at the location(s) designated above. However: 1.The insurance afforded to such additional insured only applies to the extent permitted by law; and 2.If coverage provided to the additional insured is required by a contract or agreement, the insurance afforded to such additional insured will not be broader than that which you are required by the contract or agreement to provide for such additional insured. B.With respect to the insurance afforded to these additional insureds, the following additional exclusions apply: This insurance does not apply to "bodily injury" or "property damage" occurring after: 1.All work, including materials, parts or equipment furnished in connection with such work, on the project (other than service, maintenance or repairs) to be performed by or on behalf of the additional insured(s) at the location of the covered operations has been completed; or 2.That portion of "your work" out of which the injury or damage arises has been put to its intended use by any person or organization other than another contractor or subcontractor engaged in performing operations for a principal as a part of the same project. A0112596004 00001 0000000000 21239 0 N1 164f821b-f71f-4cd7-8d0d-f4092c341581164f821b-f71f-4cd7-8d0d-f4092c341581 DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B C.With respect to the insurance afforded to these additional insureds, the following is added to Section III - Limits Of Insurance: If coverage provided to the additional insured is required by a contract or agreement, the most we will pay on behalf of the additional insured is the amount of insurance: 1.Required by the contract or agreement; or 2.Available under the applicable Limits of Insurance shown in the Declarations; whichever is less. This endorsement shall not increase the applicable Limits of Insurance shown in the Declarations. © Insurance Services Office, Inc., 2012 CG 20 10 04 13Page 2 of 2 08/27/2021A0112596 Middlesex DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B DocuSign Envelope ID: 33063F74-1DFD-4598-BE65-8C6EEC18383B WORKERS COMPENSATION AND EMPLOYERS LIABILITY INSURANCE POLICY WAIVER OF OUR RIGHT TO RECOVER FROM OTHERS ENDORSEMENT -BLANKET WC 990634 (Ed. 8-00) We have the right to recover our payments from anyone liable for an injury covered by this policy. We will not enforce our right against the person or organization named in the Schedule. (This agreement applies only to the extent that you perform work under a written contract that requires you to obtain this agreement from us). The additional premium for this endorsement shall be 2% of the total California Workers' Compensation premium otherwise due. Person or Organization Any person or organization when required by written contract. Policy Number: WSD 5025920 08 Endorsement Effective: 03/01/2022 Issue Date: 02/24/2022 WC 990634 (Ed. 8-00) Schedule Job Description All California operations Insured: Seaside Heating & Air Conditioning Inc Coverage Provided by: Insurance Company of the West Countersigned by: