HomeMy WebLinkAbout1842 CLIFF SWALLOW LN; BLDG 2; FA130010; Permit11/4/2020 FA 130010 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 1842 CLIFF SWALLOW LN Permit Type: FALARM · Parcel No: 2150507300 Lot#: 0 Reference No.: Permit No: FA130010 Status: ISSUED Applied 2/27/2013 Approved: 2/28/2013 Issued: 2/28/2013 PC #: Inspector: Project Title: LA COSTA COLLECTION HOA BLDG 2 REPLACE CURRENT POTS LINE FA COMMUNICATORS WITH GSM TECH SYSTEM Applicant: BAY ALARM COMPANY 60 BERRY DR PACHECO CA 925-935-11 00 Fees($) 286 Add'I Fees ($) 0 Owner: CITY VENTURES HOMEBUILDING L L C STE 150 3121 MICHELSON DR IRVINE CA Total($) 286 ·- Balance($) 0 1 /1 I. 4883 Ronson Court, Suite C San Diego, CA 92111 1 (800) 4 70-1000 Contractor License# 880138 PROTECTED PREMISE La Costa Collection HOA Carlsbad, CA 92011 II. MONITORING COMP ANY Bay Alarm Company ~A r3t>Ot0 r~etO' I (300 l2-60 Berry Drive Pacheco, CA 94553 800-4 70-1000 l ~et{}/? California Alarm Operating License Number: ACO28 III. EQUIPMENT SUPPLIER & INSTALLER 4883 Ronson Court, Suite C San Diego, CA 92111 1 (800) 4 70-1000 Contractor License# 880138 ~c=-=a~TYO~F~C~A-R_LS_B_AD __ FIE DEPARTMENT APPROVED lub)lct to field inspection and r ~ llltl, notations hereon, conditions In cormpondlnoe and conformance wllll appliclllle .......... TIie ..... of Ul"'l~PI---IIDI be 111111 ID Plfflll ............ o1..,11w. Date __ t< FIRE ALARM CONTROL PANEL ~ SILENT ~® KNIGHT by Honeywell Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 1 0 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones • Supervised zone expanders and 1/0 modules can be mounted remotely from the main control panel • Event History Buffer (150 events) with date/time stamp • All zones are compatible with 2-or 4-wire detectors • 8 selectable/programmable output patterns for notification appliance circuits • Built-in Digital Alarm Communicator Transmitter (DACT) • 4 Notification Appliance Circuits • 4 programmable general purpose relays • Programmable smoke verification, pre-alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms • Programmable from the built-in control panel touchpad, remote annunciator, or Windows® SKSS downloading software • Direct connect port for on-site up/downloading with Windows® SKSS downloading software • Built-in walk test feature • Single or dual interlock water releasing capability • Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions • Programmable AC trouble relay • Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor®, and Wheelock® • Programmable date settings for Daylight Saving Time • Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 voe Primary AC: 120 Vrms @ 60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: Alarm: 140 mA 460 mA Flush Mounting Dimensions: Height: 24. 75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16" (8.73 cm) with 5/8" protruding Overall Dimensions: Height: Width: Total Depth: 26-3/8" (67 cm) 17-3/16" (43.66 cm) 4"(10.16cm) Operating Temp: 32° to 120° F (0° to 49° C) Humidity: 10 -93% noncondensing Optional Accessories SK-5235 LCD Remote Annunciator SK-5217 10 Zone Expander (2 max. per system) SK-5280 Status Display Module (8 max. per system) 7181 Fire Zone Converter 5220 Direct Connect Module • 5824 Serial/Parallel Printer Interface Module SK-5208 SKSS Downloading Software • Plex-2 Door Option Listings and Approvals • UL Listed • CSFM Listed • MEA approval 429-92-E Vol. XII I cl.RE ALARM CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 .----► Telephone Line 2 .--►• Direct Connect ~-,,--------=-c,-=,11 For On-Site Programming 2 Class A (Style D) or Class B (Style 8)..-.-... -----• Programmable Initiation Circuits Form C Relays 8 Class B (Style 8) ..._._ ... Initiation Circuits · a---11► Notification ~ SILENT KNIGHT by Honeywell Appliance Circuits 5235 Remote Annunciators •t---....j~ SBUS Devices ToAC This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com 5280, 5217, & 5824 MADE IN AMERICA FORM# 350318 Rev C © 2010 Honeywell International Inc. DSC A Tvco !mernat/onal ··I\Jlak:e.>a Diffe~ence: <~~~-~ ~ .. g~1 (3~) ns3twprk for··· ... • .. . high~speea, reliable and low~ .. . cost cornmunicfltions to an IP Automc1t!9ally ~~tcn~~Jo 2$ (EDGE/GPRS) if ~G ser-vice is not available Full event reporting 4 on~board inputs 4 Onimcird outputs.(open c~I1~~~~fu{ ) < .)· . SIM ·card(ihclucied) " . '' ::. . . . ... ::.· Activatioo and lriitia.lization via t . ' automated telephonesactivation system· (VRU), web ... u~§rOr rnobile interface proviaed by C24 Con,munications • PTM (Pc1i:1el Trar,smission Monitor)switct'.les fromPSTl'N to cellular on unsuccessful cornm~nication ~;tt~rnpt$ .. ..... ;. .. . :::.::::r-::: ... ":•'. ·:::,:._.. :,· ,. .. C6h1p9tlbl~ with Sur;Gard® Systerfrl/117III/IVmonitoring station receivers lndudes UL supply, tra recharge 3G technology from DSC! The 3G3070CF connects the alarm control panel to the HSPA network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System 1/11/111/IV). The 3G3070CF uses the HSPA network to ensure low- cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID format. The 3G3070CF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 Edition. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DAC1). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G3070CF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G3070CF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the HSPA network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the HSPA network to the monitoring station. In instances where the control panel does not support Contact ID, the 3G3070CF has inputs pre-set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station receiver (Sur-Gard® System 1/11/111/IV). Activating & initializing the unit Activating and initializing the 383070 can be done using the automated telephone activation system (VRU), mobile interface or web-user interface provided by CONNECT 24. No special tools are required. UL Listing The 3G3070CF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator the 3G3070CF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a backup communicator the 3G3070CF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G3070CF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. Ordering Information: 3G3070CF-USA ..... Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) DSC A Tvco lntemat.!ona! Companv Specifications Dimensions ................................................ 11-1 /2" x 1 O" x 311 (29.2 cm x 25.4 cm x 7.62 cm) Input Voltage ............................................................. 120 VAC Current Draw .............................................................. 300 mA Operating Environment ................ 0° to 48° C (32° to 120° F) Weight... ........................................................ 12.8 lbs (5.8 kg) RM-2 Relay Module Installation Instructions The RM-2 Relay Module is used as an end-of-line (EOL) power supervision module for 4-wire smoke detectors. The RM-2 is used with the Polarity Reversal Module PRM- 4W and DSC FSA-41 O series smoke detectors. When the PRM-4W reverses polarity on the smoke detector loop to activate all smoke detector sounders, the RM-2 Relay will continue to operate normally (regardless of input power polarity). Refer to the PRM-2W/4W Polarity Reversal Module Installation Instructions Technical Specifications: Operating Voltage Range: ............................................................. 10VDC to 30VDC Relay Contact Rating: ..................................................................... 2A@30VDCNAC Current Rating: .............................................................................................. 25mA Operating Environment: ................... .-............................... 0°c -49°C (32°F -120°F) .............................................................................. 5% -93% RH (non-condensing) Size (H x W x D): ................................... 28.5 x 86 x 21 mm/ 1 1/8 x 3 % x 718 in. Terminal Wire Gauge: ............................................................................ 14-22 AWG Connection Diagram Run the connection wires through the wiring holes on the back of the unit. Mounting To mount the unit, remove the plastic cover and secure the unit to the desired loca- tion with the screws provided. Replace the cover. The module can also be mounted inside a standard 4" electrical box (1.5" deep) if required by the installation. Please refer to the diagrams below: 4-WIRE SMOKE DETECTORS PRM-4W FSA-410 Series Polarity Reversal Module 4-wire Smoke Detector Control Panel Q l~~~~~I ~ ~12Voc~_+_J-r~ ~_I-__ z_f T BLK'II~ D II _R_EDIM D L__J 0 IO DSC RM-2 Relay Panel EOLR Mounting of the Relay in an Electrical Box LIMITED WARRANTY 4-Wire Smoke Detector FSA-41 Ox Smoke Detector Mounting Plate Power Supervision Relay RM-2 Electrical Box (1.5" deep) Digital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the product shall be free of defect in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or improper application of the equipment. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Se- curity Controls Ltd. This warranty contains the entire warranty. Digital Security Controls Ltd. neither as- sumes, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. In no event shall Digital Security Controls Ltd. be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product. WARNING : Digital Security Controls Ltd. recommends that the entire system be completely tested on a reg- ular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electri- cal disruption, it is possible for this product to fail to perform as expected. ~~® .inr-.,,,,,,.......,, ©2003 Digital Security Controls Ltd. Toronto, Canada • www.dsc.com Printed in Canada II IIIIII II I I II II II IIII Ill 111111111111111 29034640R002 Direct all comments concerning this publication to pubs@dscltd.com LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0559:0137 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mcisaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com Page 1 of 1 Model SK-5208 fire alarm control unit. Power-limited, automatic, manual, remote station, central station, waterflow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: SK5208 Control Unit SK-5220 Direct Connect Module SK-5280 Status Display Module SK-5217 Zone Expander SK-5235 Remote Annunciator SK-2190 Enclosure SK-7181 Zone Converter In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2012 JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Listing Expires June 30, 2013 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1273:0140 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@dsc.com Model 3G3070-CF, RF communicator (GSM-GPRS or 3G/HSPA network) signaling device. It is intended for use as a standalone communication technology (standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. It is used for central station fire and burglar alarm system communication, which employs a GSM-GPRS or 3G/HSPA (cellular) communication as its signaling medium. This product is to be connected to a listed control panel in accordance with the installation instructions provided with the Model 3G3070-CF transceiver. A Motorola radio, Model H24, connects to an interface board, Model UA595, to form a Model 3G3070-CF communicator, which is intended to be installed at each protected premise. The Model 3G3070-CF is housed in its own metal enclosure and can connect to any separately listed control unit through a telephone line connection or using its inputs connected to dry contacts outputs from the fire alarm control panel for alarm, supervisory, or trouble transmissions. Refer to listee's data sheet for additional detailed product description and operational considerations. 120 V, 50/60 Hz, 0.3 A In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. 02-09-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2012 JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Listing Expires June 30, 2013 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1273:0127 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@dsc.com Models PRM-2W, -2WC (for 2-wire smoke detectors), PRM-4W, -4WC(for 4-wire smoke detectors) power reversal modules and RM-2 power supervision relay modules. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 09-30-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2012 JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Listing Expires June 30, 2013