HomeMy WebLinkAboutPRE 2022-0050; ZAVALANI; Admin Decision LetterOctober 21, 2022
KIRK MOELLER
KM ARCHITECTS
2888 LOKER AVENUE, SUITE 200
CARLSBAD, CA 92010
B FILE COPY
SUBJECT: PRE 2022-0050 (DEV2022-0185) -ZAVALANI
APN: 204-173-09-00
Dear Mr. Moeller,
{'city of
Carlsbad
Thank you for subrriitting a preliminary review application for a residential project proposed on an
approximately 12,612-square-foot (0.29-acres) developed lot located within the Barrio-Center (BC)
District of the Village and Barrio Master Plan at 722-730 Magnolia Avenue. The proposed project generally
involves two (2) distinct components best described as follows:
• 524 square feet of additions to two (2) existing 822-square-foot attached dwelling units, which
would increase each unit's total living area to 1,346 square feet at build-out; and
• The addition of two (2), newly proposed, detached accessory dwelling units (non-mandatory),
each 1,200 square feet in size (located on a single lot developed with an existing residential
structure containing two (2) attached dwelling units).
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans, policies, and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal, new plans, policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and zoning designations for the property are as follows:
a. General Plan: V-B (Village-Barrio)
b. Zoning: V-B (Village-Barrio)
c. Village and Barrio Master Plan (Barrio Center (BC) District)
Community Development Department
Planning Division J 1635 Faraday Avenue Carlsbad, CA 92008-7314 J 442-339-2600 www.carlsbadca.gov
PRE 2022-0050 (DEV2022-0185) -ZAVALANI
October 21, 2022
Page 2
2. The project requires the following:
a. · Building Permit
b. Grading Permit
c. Grading Plan
d. Landscape Plan
3. The two (2), newly proposed, 1,200-square-foot accessory dwelling units are limited to a maximum
16-foot-tall building height. Please see the City of Carlsbad's Guide to Measuring Building Height for
assistance in preparing future construction documents. This guide can be accessed on the city's
website at the following web address:
https://www .ca rlsbadca .gov /home/showpubl isheddocu ment/268/637 425976538130000
4. While the two (2), newly proposed, 1,200-square-foot accessory dwelling units are allowed per state
law, the amount of expansion allowed to the two (2) existing attached dwelling units (722-730
Magnolia) will be limited to the ability to provide the required amount of open space onsite pursuant
to CMC 21.45.070, Table D, reference number D.12 (Section 2.7.7.E. Barrio Center Supplemental
District Standards, pg. 2-68). As part of the Building Permit Site Plan and associated Landscape Plan
submittal discussed above, please plotthe dimensions and area (sq. ft.) of this open space and label
it accordingly.
5. Home Owner Association (HOA) authorization is required for ADUs proposed in multi-family
condominium common areas. As part of the formal building permit submittal process, please provide
a written statement attesting that there is no HOA governing this property, and/or that property is
not a condominium. Otherwise provide proof of HOA authorization.
6. While the two (2), newly proposed, 1,200-square-foot accessory dwelling units are not required to
provide parking, the proposed expansion of the two (2) existing attached dwelling units (722-730
Magnolia) does trigger off-street parking requirements. As part of your building permit submittal,
please revise your site plan configuration to provide two (2) off-street parking spaces for each of the
existing units. Please see CMC Sections 21.44.010.A.2.a. and 21.44.060 for specific requirements.
More specifically, please revise the current parking/site configuration to comply with CMC Section
21.44.060.A.4-Table E as it relates to where vehicles can be parked in a residential zone. Each driveway
shall be a minimum 20-feet in depth (from property line) and 24-feet in width. Please contact Land
Development Engineering for any sidewalk, curb, and gutter improvements that may be necessary to
achieve above compliance.
7. As part of building permit submittal, please provide within the construction documents/project
information sheet(s), lot coverage calculations demonstrating compliance with the maximum 70%
that is allowed pursuant to the Barrio Center (BC) District of the Village and Barrio Master Plan.
8. It appears this project is modifying greater than 2,500 square-feet of existing landscape area; and
thus, is subject to the city's Landscape Manual (February 2016). Please submit a landscape plan to the
Planning Division together with the submittal of building and grading permits as discussed herein. The
city's Landscape Manual can be accessed on the city's website at the following web address:
PRE 2022-0050 (DEV2022-0185) -ZAVALANI
October 21, 2022
Page 3
https:ljwww.carlsbadca.gov/home/showpublisheddocument/11160/637985942877070000
9. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely
impact development requirements of this project. A formal application submittal will need to include
a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to
the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric
vehicle charging, water. heating and traffic demand management requirements, as set forth in the
California Gre~n Building Standards Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and
18.51 which is available on the city's website at the following address:
http:ljwww.qcode.us/codes/carlsbad/view.php?topic=18&frames=on
To the extent that new GHG reduction requirements are in effect at the time of application for grading
or building permits, the project will be required to comply with the effective requirements even if
different than what is proposed in the project's planning approvals. GHG reduction requirements may
impact, but are not limited to, site design and local building code requirements. If incorporating new
GHG reduction requirements results in substantial modifications to the project after planning
approvals are obtained, then prior to issuance of grading or building permits, the applicant may be
required to submit and receive approval of a Consistency Determination or an Amendment
application for the project through the Planning Division.
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
https://www.carlsbadca.gov/departments/community-development/planning. You may also access the
General Plan Land Use Element and the Zoning Ordinance online at the website address shown. Please
review all information carefully before submitting.
Land Development Engineering:
1. Complete a Stormwater Standards Questionnaire Form E-34. This questionnaire will guide you
and the city in determining what type of reports and storm water mitigation must be completed
to satisfy state and City storm water quality requirements. The questionnaire is located on the
City of Carlsbad website.
All proposed or replaced impervious surface needs to be tabulated and included on Form E-34,
which include impervious surface within the r.ight-of-way. Clarify if the proposed driveway
approach on site will be impervious surface, if it is it shall be included in the quantity on Form E-
34.
2. Based on a preliminary analysis it appears that this project will be a Standard Project. Complete
the Standard Project Requirement Checklist, Form E-36, and show all source and site design BMPs
on the conceptual grading and drainage plans.
3. Based on this project general land use (Village-Barrio), this project is subject to the City of Carlsbad
trash capture requirements for the entire property. Incorporate trash capture measures on the
project plans. Provide trash capture calculations and prepare a preliminary Trash Capture Storm
PRE 2022-0050 (DEV2022-0185) -ZAVALANI
October 21, 2022
Page 4
Water Quality Management Plan. The template form, E-35A, for the trash capture storm water
quality management plan is located on the City of Carlsbad website.
4. Submit a Climate Action Plan (CAP) Checklist, Form P-30, to demonstrate project compliance with
the CAP.
5. Provide a preliminary title report within six (6) months of the application date, with current
ownership. Label and annotate all existing easements affecting the property on the site plan.
6. The project may require a certificate of compliance for lot legality. Please provide chain of title
documentation with the earliest deed that conveyed the property with the current legal
description, so that the city can assess if .this is required.
7. Provide typical street cross sections for Madison Street and Magnolia Avenue, clearly show the
existing right-of-way, centerline and dimensions to the existing curb and existing sidewalk.
8. The existing driveways shall be removed and replaced with ADA compliant driveways per San
Diego Regional Standard Drawing G-14A.
9. The proposed driveways shall be designed per Section 3.15 of Volume 1 of the City of Carlsbad
Engineering Standards.
10. The existing ramp at the northeast corner of M9dison Street and Magnolia will be required to be
removed and replaced with an ADA compliant ramp.
11. Additional street right-of-way may be required on Magnolia Avenue to facilitate ADA accessible
path with new driveway configuration.
12. Indicate the volume of grading (cut, fill, import, export, remedial) proposed for the project in cubic
yards. The remedial quantities shall be determined by the recommendations of a geotechnical
engineer.
13. Per CMC Section 15.16.060, a preliminary analysis suggests this project will require a grading
permit and grading plan.
14. Provide a conceptual grading plan, delineate existing and proposed contours, spot elevations and
the method for draining the facilities around the proposed ADU's and the addition per GS-15 and
CBC1804.4. Provide finish floor and pad elevations.
15.. If any retaining walls will be. utilized on the project site, show top-of-wall and bottom-of-wall
elevations. Indicate maximum height of retaining wall, show footing and remedial excavation
required in cross sections.
16. Provide bearing and distance for all property lines shown.
17. Provide a vicinity map to the site plan.
PRE 2022-0050 (DEV2022-0185) -ZAVALANI
October 21, 2022
Page 5
18. Show all existing utilities: water, sewer, storm drain, dry utilities and overhead lines in Madison
Street and Monroe Avenue and laterals affecting the property.
19. Delineate and annotate how sewer and water facilities will be provided to the proposed ADU's.
20. Show existing topographic information within 15 feet of the property line, including fences, walls,
structures, contours, and existing utilities.
21. Removal of any trees within the City of Carlsbad tree inventory will require approval per CMC
Section 11.12.090. Show existing trees and disposition.
22. It appears that the existing fence on Madison Street is within the existing public right-of-way. As
part of this project, move the existing fence out of the right-of-way.
23. Provide multiple cross-sections of the site to demonstrate differences in grade, including adjacent
properties, show existing ground, fences and existing adjacent structures. Also show proposed
improvements and any remedial excavation required and shoring needed to construct.
24. Show the vertical datum and benchmark used for the existing contours shown on the site plan.
NGVD 29 datum for vertical control for all design elevations per city Engineering Standard Volume
1, Chapter 2.
25. Please be advised that a more in-depth review of the proposed development will occur with the
permit application, when a more complete design of the project is provided.
26. Please see the enclosed redlines for additional comments.
Fire Department:
1. NFPA 13D fire sprinklers are required throughout the existing structures and additions, as well as
the future accessory dwelling units.
Building Division:
1. Show details for one-hour fire resistance rated wall(s) separating the accessory dwelling units
from the adjacent property line (CRC R302.3).
2. A soils report is required for new construction. Please prepare the report and include
recommendations into the foundation design.
3. A boundary certification is required for new structures built five (5) feet or closer to a side or rear
yard property line.
4. Sewer design with fixture unit counts is required for the entire sewer line, including new accessory
dwelling units (ADU). if..the ADU's tie into the existing sewer line prior to the sewer main
connection.
PRE 2022-0050 (DEV2022-0185) -ZAVALANI
October 21, 2022
Page 6
5. Electrical load calculations and single line diagram is required for entire electrical design, including
the existing loads and new ADU loads.
6. Carlsbad Climate Action Plan (CAP), Sections 2A, 3A and 4A are triggered for this project and new
detached accessory dwelling units. CAP specific plan details to be coordinated with the CF1-R
energy documents.
7. Single line diagram for proposed gas fixtures is required, including the new house fixtures.
8. Separate HVAC will be required for the accessory dwelling units (AD Us):
a. Each dwelling unit shall be provided with heating facilities capable of maintaining a 68-
degree room temperature.
b. Return air from one dwelling unit shall not discharge into another dwelling unit
(CMC311.4).
c. Each dwelling unit shall be controlled by its own thermostat (CEC 120.2(a)).
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Jason Goff at the number below. You may also contact each department individually as follows:
• Planning: Jason Goff, Senior Planner, at (442) 339-2643
• Land Development Engineering: Nicole Fine, Project Engineer, at (442) 339-2744
• Fire Prevention: Randy Metz, Fire Inspections, at (442) 339-2661
• Building: Jason Pasiut, Building Official, at (442) 339-2788
Sincerely,
ERIC LARDY, AICP
City Planner
EL:JG:JC
Enclosures:
1. LDE Redlines
c: Rudy Zavalani, 1868 Crest Drive, Encinitas, CA, 92024
Nicole Fine, Project Engineer
Fire Prevention
Laserfiche/File Copy
Data Entry
C) 0 z C) m "ti -I C: )> I'"' !II ::j m
"ti !j;: z
I I I
I B
. I i • ~ !
I
i ~H !U ,. F u H I ~ j
r ii ~Xij ii~ ii~ I 'I 11 • • · Lt11 I j I 1m11
I a;;u ipq 11 »ohi I q . . ~ ~ i g i i' ·I ;, i1 I i.~ 1ir~1 f 'W i j ... 'U I• f 1~1 ' g q iiPI I •• I 1~11 i !
11 ; ~
h I I H r , .
.. ~ ~ ~ m~ ~m Hj•u•-p;,nrr h fi ,u iii ii iii iilii1 • g ~
11 11 •
~ f ~iii• 1 MAGNOLIA RENOVATIONS 11! ! r -ccnr f 'Ii TI~ i 722 • 730 MAGNOLIA !l j
..... -_ ...... _____ ..._. ........................ ~ .. R-! ...... c_A_R_L_s_B_A_o_, c_A ___________ .. ._ ___ _._ ____ ___,_i.;..;_. _ __,_ _ __.