HomeMy WebLinkAbout1540 WEATHERLY RD; ; CBR2020-3049; PermitPrint Date: 11/15/2022 Permit No: CBR2020-3049
Building Permit Finaled
Residential Permit
Job Address:
Permit Type:
Parcel #:
Valuation:
Occupancy Group:
1540 WEATHERLY RD, CARLSBAD, CA 92011-4040
BLDG-Residential
2150720900
$10,046.16
Work Class:
Lot #:
Project #:
Alteration
Status:
Applied:
Issued:
11/22/2020
04/07/2021
Finaled Close Out:11/15/2022
#of Dwelling Units:
Track #:
Plan #:
Closed - Finaled
Plan Check #:
Orig. Plan Check #:Bathrooms:
Final Inspection:12/10/2021Bedrooms:Construction Type:
Occupant Load:
Code Edition:
Sprinkled:
INSPECTOR:Dreibelbis, Peter
Kersch, Tim
Renfro, Chris
Alvarado, Tony
216 SF REMODEL TO CONVERT THIRD CAR GARAGE TO BED/BATH (E-REVIEW)Description:
Project Title:
Applicant: PERMIT RUNNER
9880 N MAGNOLIA AVE, # 119
SANTEE, CA 92071-1901
(619) 933-4868
Property Owner: CO-OWNERS HESS KRISTINA AND WAGONER
DARREN M
1540 WEATHERLY RD
CARLSBAD, CA 92011
AMOUNTFEE
BUILDING PERMIT FEE ($2000+)$123.83
BUILDING PERMIT FEE ($2000+)$123.83
BUILDING PLAN CHECK FEE (BLDG)$86.68
BUILDING PLAN CHECK FEE (BLDG)$86.68 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $41.00
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $41.00
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $39.00
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $39.00 PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $49.00
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $49.00
SB1473 GREEN BUILDING STATE STANDARDS FEE $1.00
SB1473 GREEN BUILDING STATE STANDARDS FEE $1.00 STRONG MOTION-RESIDENTIAL $1.31
STRONG MOTION-RESIDENTIAL $1.31
Total Fees:$683.64 Total Payments To Date:$683.64 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad CA 92008-7314 ï 442-339-2719 ï 760-602-8560 f ï www.carlsbadca.gov
Building Division Page 1 of 1
{"Cityof
Carlsbad
Plan Check
Est. Value
PC Deposit
Date
B-1 Page 1 of 2 Rev. 06/18
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Job Address __________________________________________Suite: __________ APN: _________________________
CT/Project #:______________________ Lot #:_________ Fire Sprinklers: yes / no Air Conditioning: yes / no
BRIEF DESCRIPTION OF WORK: ________________________________________________________________________
__________________________________________________________________________________________________
APPLICANT (PRIMARY) PROPERTY OWNER
Name: ________________________________________ Name: _____________________________________________
Address: ______________________________________ Address: ____________________________________________
City: _________________ State:______Zip: _________ City: ______________________State:______Zip: ___________
Phone: _______________________________________ Phone: _____________________________________________
Email: ________________________________________ Email: ______________________________________________
DESIGN PROFESSIONAL CONTRACTOR BUSINESS
Name: ________________________________________ Name: _____________________________________________
Address: ______________________________________ Address: ___________________________________________
City: _________________ State:______Zip: __________ City: _________________ State:______Zip: _______________
Phone: _______________________________________ Phone: ____________________________________________
Email: ________________________________________ Email: _____________________________________________
Architect State License: __________________________ State License:_____________ Bus. License:_______________
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor’s License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
Addition/New: ____________Living SF, ________ Deck SF, ________ Patio SF, ________Garage SF
Is this to create an Accessory Dwelling Unit? Yes / No New Fireplace? Yes / No, if yes how many? _____
Remodel: __________ SF of affected area Is the area a conversion or change of use ? Yes / No
Pool/Spa: __________ SF Additional Gas or Electrical Features? _____________________________
Solar: _______ KW, ______ Modules, Mounted: Roof / Ground , Tilt: Yes / No, RMA: Yes / No, Battery: Yes / No
Panel Upgrade: Yes / No
Reroof: ____________________________________________________________________________________
Plumbing/Mechanical/Electrical Only: ___________________________________________________________
Other: ______________________________________________________________________________________
_______________________________________________________________________________________________
CBR2020-3049
10046
11/22/2020
1540 Weatherly Rd 215-072-09-00
216 sf - convert third car garage to bed/bath
216
Jennifer Cole Kristina & Darren Hess
9880 N Magnolia Ave #119
Santee CA 92071 Carlsbad CA 92011
619-933-4868 (858) 945-8725
jennifer@permitrunner.net
KING REMODELING
7950 SILVERTON AVE #206
SAN DIEGO CA 92126
(858) 299-7700
1039019 8116-07-20
1540 Weatherly Rd
Iii
Iii
□
□
□
□
□
( City of
Carlsbad
B-1 Page 2 of 2 Rev. 06/18
( OPTION A ): WORKERS’COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers’ compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
I have and will maintain worker’s compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers’ compensation insurance carrier and policy number are: Insurance Company Name: _______________________________________________
Policy No. _______________________________ Expiration Date: _______________________
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come
subject to the workers’ compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney’s fees.
CONTRACTOR SIGNATURE: _____________________________________________ AGENT DATE: _______________
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor’s License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor’s License Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor’s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor’s License Law).
I am exempt under Section __________________Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Yes No
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors’ license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone /
contractors’ license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
OWNER SIGNATURE: ______________________________________________ AGENT DATE: _______________
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender’s Name: ___________________________________________________ Lender’s Address: ___________________________________________________
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5’0’ deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
APPLICANT SIGNATURE: __________________________________________________ DATE: ____________________
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
________________________________________________________________________________________
y(
__________________________________________________________________________________________________________________________________
STATE COMPENSATION INS
9230727 05/02/2021
11/22/2020
11/22/2020
•
□
Building Permit Inspection History Finaled
PERMIT INSPECTION HISTORY for (CBR2020-3049)
BLDG-Residential 11/22/2020Application Date:Permit Type:Owner:COOWNER HESS KRISTINA &
WAGONER DARREN M
Alteration 04/07/2021Work Class:Issue Date:Subdivision:CARLSBAD TCT#93-09A OCEAN
BLUFF
06/13/2022Expiration Date:Status:
IVR Number: 30117
Closed - Finaled 1540 WEATHERLY RD
CARLSBAD, CA 92011-4040
Address:
Scheduled
Date
Inspection Type Inspection No. Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
11/03/2021 11/03/2021 BLDG-21
Underground/Underflo
or Plumbing
169955-2021 Passed Tony Alvarado Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency November 3, 2021: (garage conversion to
habitable condition space).
1. No deficiencies.
2. Underground plumbing waste and vent
lines under water leak, 10' ft. high head
pressure test, scope of underground
plumbing work – approved.
Yes
11/15/2021 11/15/2021 BLDG-11
Foundation/Ftg/Piers
(Rebar)
170825-2021 Passed Tony Alvarado Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency November 15, 2021:
1. No garage additional infill square footage
added-Deficiencies.
2. New steel reinforcement rebar, installed
within existing garage location envelope to
accommodate new condition/habitable,
living space, Located within existing 3-car
garage area.
3. Installed new #4 steel reinforcement
rebar at every 18" inches on center,
cold-joint between existing garage
stemwall footing and slab, per engineers
plans and detail specifications-approved.
Yes
BLDG-12 Steel/Bond
Beam
170715-2021 Passed Tony Alvarado Complete
Monday, January 31, 2022 Page 1 of 3
{cityof
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2020-3049)
BLDG-Residential 11/22/2020Application Date:Permit Type:Owner:COOWNER HESS KRISTINA &
WAGONER DARREN M
Alteration 04/07/2021Work Class:Issue Date:Subdivision:CARLSBAD TCT#93-09A OCEAN
BLUFF
06/13/2022Expiration Date:Status:
IVR Number: 30117
Closed - Finaled 1540 WEATHERLY RD
CARLSBAD, CA 92011-4040
Address:
Scheduled
Date
Inspection Type Inspection No.Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
COMMENTS PassedChecklist Item
BLDG-Building Deficiency November 15, 2021:
1. No swimming pool and spa Deficiencies.
2. Swimming pool and spa, engineered,
steel rebar reinforcement, per structural
engineered Todd locker plans and detail
specifications-approved.
3. Equipotential pool copper bond wire
tails, located at four points perimeter of
swimming pool and spa-partial pass.
4. Underground plumbing lines under water
leak pressure test-approved.
5. underground gas line with tracer wire,
underground electrical conduit, depth
protection, and under water leak and air
pressure test-not ready.
6. Preconstruction requirements and
checklist reviewed with contractor
representative Dan.
Yes
11/30/2021 11/30/2021 BLDG-14
Frame/Steel/Bolting/We
lding (Decks)
171521-2021 Passed Peter Dreibelbis Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency No
BLDG-84 Rough
Combo(14,24,34,44)
171571-2021 Passed Peter Dreibelbis Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency No
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
No
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44
Rough-Ducts-Dampers
No
12/10/2021 12/10/2021 BLDG-Final Inspection 172323-2021 Passed Tim Kersch Incomplete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency No
BLDG-Plumbing Final Shower pan.Yes
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
12/13/2021 12/13/2021 BLDG-16 Insulation 172322-2021 Passed Chris Renfro Complete
Monday, January 31, 2022 Page 2 of 3
PERMIT INSPECTION HISTORY for (CBR2020-3049)
BLDG-Residential 11/22/2020Application Date:Permit Type:Owner:COOWNER HESS KRISTINA &
WAGONER DARREN M
Alteration 04/07/2021Work Class:Issue Date:Subdivision:CARLSBAD TCT#93-09A OCEAN
BLUFF
06/13/2022Expiration Date:Status:
IVR Number: 30117
Closed - Finaled 1540 WEATHERLY RD
CARLSBAD, CA 92011-4040
Address:
Scheduled
Date
Inspection Type Inspection No.Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Completed by Jason Pasiut on 12/9/2021 Yes
BLDG-27 Shower
Pan/Tubs
172324-2021 Passed Chris Renfro Incomplete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Completed by Jason Pasiut on 12/9/2021 Yes
12/15/2021 12/15/2021 BLDG-17 Interior
Lath/Drywall
172835-2021 Partial Pass Tony Alvarado Reinspection Incomplete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency December 15, 2021:
1. Interior shower stall enclosure, installed
red guard/moisture resistive cement board,
anchoring method of attachment-approved.
2. First floor, downstairs bedroom, gypsum
board/drywall method of attachment
anchoring pattern – approved.
Yes
BLDG-27 Shower
Pan/Tubs
172732-2021 Partial Pass Tony Alvarado Reinspection Incomplete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency December 15, 2021:
1. Interior shower stall enclosure, installed
red guard/moisture resistive cement board,
anchoring method of attachment-approved.
2. First floor, downstairs bedroom, gypsum
board/drywall method of attachment
anchoring pattern – approved.
Yes
01/31/2022 01/31/2022 BLDG-Final Inspection 175550-2022 Passed Tony Alvarado Complete
COMMENTS PassedChecklist Item
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Monday, January 31, 2022 Page 3 of 3
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 (858) 560-1468 Fax (858) 560-1576
DATE: 12/10/2020 APPLICANT JURIS. JURISDICTION: City of Carlsbad
PLAN CHECK #.: CBR2020-3049 SET: I
PROJECT ADDRESS: 1540 Weatherly Rd
PROJECT NAME: SFD Partial Garage Conversion to Bedroom Space
The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to: Jennifer Cole
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Jennifer Cole Telephone #: 619-933-4868
Date contacted: (by: ) Email: jennifer@permitrunner.net
Mail Telephone Fax In Person
REMARKS:
By: Ali Doudar Enclosures:
EsGil
I
□
□
□
□
□
~
□
✓• EsG1I
A SAFEbuilfCompany
City of Carlsbad CBR2020-3049 12/10/2020 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK #.: CBR2020-3049 JURISDICTION: City of Carlsbad PROJECT ADDRESS: 1540 Weatherly Rd
FLOOR AREA: 216 SF New living Space (Alteration) STORIES: 2
HEIGHT: 8'-6"
REMARKS:
DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: I DATE INITIAL PLAN REVIEW PLAN REVIEWER: Ali Doudar
COMPLETED: 12/10/2020
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the California Residential Code, California Building Code, California Plumbing Code, California Mechanical Code, California l Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC,
2019 CPC, 2019 CMC and 2019 CEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2019 California Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad CBR2020-3049 12/10/2020 PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete.
1. A reminder that due to Covid-19, the City will not permit counter corrections.
Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary.
2. City of Carlsbad requires that all plans provide completed Climate Action Plan (CAP) Consistency Checklist, city form B-50, and show on title sheet of plans completed CAP template, city form B-55. 3. Indicate on the Title Sheet of the plans the name of the legal owner and name of the person responsible for the preparation of the plans. Section R106.1.1.
4. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 5. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, garage, carport, patio, deck and balcony. Section
R106.2. 6. Show a self-closing and self-latching door or an automatic- closing and latching door; either 1-3/8" solid core or a listed 20-minute assembly, for openings between garage and dwelling. Section R302.5.1.
7. Clarify door schedule with floor plans. Three proposed doors are shown on the plans and only 2 on the schedule. 8. For garage conversions: CRC Section R506 requires a vapor retarder for all
slabs below conditioned space. Please provide verification that a vapor retarder was installed at the time of construction; or demonstrate how slab will be
City of Carlsbad CBR2020-3049 12/10/2020
moisture-proofed. Include product manufacturer, method of application, and ICC (or equal) approval.
ELECTRICAL 9. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
10. Per CEC Article 210.11(C)3, note on the plans that bathroom circuiting shall be either:
a) A 20-ampere circuit dedicated to each bathroom, or
b) At least one 20 ampere circuit supplying only bathroom receptacle outlets. PLUMBING
11. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8
GPM of flow. CPC Sections 407, 408, 411, 412.
RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building
Standards Code and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, along with additions/alterations that increase the building’s conditioned area, volume
or size. CGC Section 301.1.1. Provide a sheet on the plans labeled “Green Building Code Requirements” and include the following notes as applicable. 12. Electric Vehicle Charging. Note on the plans that electrical vehicle supply
equipment (EVSE) is required in NEW one- and two-family dwellings and
townhomes with attached garages. Include the following information on the plans: A minimum size 1" conduit originating from a panel or service having a spare 40 ampere 240-volt capacity terminating in a box located in close proximity to the location of the future EV charger. CGC 4.106.4.
13. Storm water drainage/retention during construction. Note on the plans:
Projects which disturb less than one acre of soil shall manage storm water drainage during construction by one of the following: A. Retention basins. B.
City of Carlsbad CBR2020-3049 12/10/2020
Where storm water is conveyed to a public drainage system, water shall be filtered by use of a barrier system, wattle or other approved method. CGC Section 4.106.2.
14. Grading and paving. Note on the plans that site grading or drainage system will
manage all surface water flows to keep water from entering buildings (swales,
water collection, French drains, etc.). CGC Section 4.106.3. Exception: Additions not altering the drainage path.
15. Indoor water use. Show compliance with the following table, per CGC Section 4.303.1.
FIXTURE FLOW RATES
FIXTURE TYPE MAXIMUM FLOW RATE
Water closets 1.28 gallons/flush
Urinals (wall-mounted) 0.125 gallon/flush
Urinals (others) 0.5 gallon/flush
Showerheads 1.8 gpm @ 80 psi
Lavatory faucets 1.2 gpm @ 60 psi1
Kitchen faucets 1.8 gpm @ 60 psi
Metering faucets 0.20 gallons per cycle
1. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi.
16. Note on the plans that when a shower is provided with multiple shower heads,
the sum of flow to all the heads shall not exceed 1.8 gpm @ 80 psi, or the shower shall be designed so that only one head is on at a time. CGC Section 4.303.1.3.2.
17. Note on the plans that landscape irrigation water use shall have weather or soil-based controllers. CGC Section 4.304.1.
18. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled. CGC Section 4.408.1.
19. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan, per CGC Section 4.408.2.
20. Operation and maintenance manual. Note on the plans that the builder is to
provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC Section 4.410.1.
21. Note on the plans that the gas fireplace(s) shall be a direct-vent sealed-combustion type. Woodstove or pellet stoves must be US EPA Phase II rated appliances. CGC Section 4.503.1.
City of Carlsbad CBR2020-3049 12/10/2020
22. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC Section 4.504.1.
23. Pollutant control. Note on the plans that VOC’s must comply with the
limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and
4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC Section 4.504.2.
24. Interior moisture control. Note on the plans that concrete slabs will be provided with a capillary break. CGC Section 4.505.2.1.
25. Interior moisture control. Note on the plans that the moisture content of wood
shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in
CGC Section 4.505.3.
26. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1.
27. Heating and air-conditioning system design. Heating and air conditioning
systems shall be sized, designed and have their equipment selected using the
following methods: (Support documentation required at application submittal) 4.507.2. a) Establish heat loss and heat gain values according to ANSI/ACCA Manual
J-2016, ASHRAE handbooks or other equivalent methods.
b) Size duct systems according to ANSI/ACCA 1 Manual D – 2016, ASHRAE handbooks or other equivalent methods. c) Select heating and cooling equipment according to ANSI/ACCA 3 Manual
S – 2014 or other equivalent methods.
Exception: Use of alternate design temperatures necessary to ensure the systems function are acceptable
28. Note on the plans that prior to final inspection the licensed contractor, architect or
engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3.
a) Complete a Residential Occupancies Application Checklist that includes
the minimum criteria. It is available at: https://www.hcd.ca.gov/building-
standards/calgreen/cal-green-forms.shtml
City of Carlsbad CBR2020-3049 12/10/2020 ENERGY CONSERVATION 29. All domestic hot water piping to have the following minimum insulation installed: ½” pipe (1/2” insulation); ¾” pipe (1” insulation); 1” to 1-½” pipe (1-½”
insulation). CPC 609.11 & ES 150.0(j)
a) Additionally, the ½” hot water pipe to the kitchen sink, and the cold-water pipe within 5’ of the water heater both require 1” minimum insulation. ES 150.O(j)
30. Below grade hot water piping is required to be installed in a waterproof and non-
crushable sleeve or casing that allows for replacement of both the piping and insulation.
Residential Energy Lighting Requirements: ES 150.0(k)
31. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A.
a) Luminaries must have a label certified for airtight construction.
b) Light sources that are not marked “JA8-2019-E” shall not be installed in enclosed luminaires. ES 150.0(k)
32. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet).
33. Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k)
Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2
34. Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior.
Provide CFM rating of proposed exhaust fan. A bathroom is defined “as a room
with a bathtub, shower, or spa or some similar source of moisture”.
Additions (Mandatory)
35. Fenestration alterations must meet all requirements of ES 150.1(c) and Table 150.1-A. Provide SHGC and U-factor for all proposed exterior fenestration (Windows C and F). Max u-factor = 0.30 , Max SHGC = 0.23
MISCELLANEOUS
City of Carlsbad CBR2020-3049 12/10/2020
36. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
37. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list? Please indicate: Yes No
38. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ali Doudar at EsGil. Thank you.
City of Carlsbad CBR2020-3049 12/10/2020
[DO NOT PAY – THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK #.: CBR2020-3049
PREPARED BY: Ali Doudar DATE: 12/10/2020
BUILDING ADDRESS: 1540 Weatherly Rd
BUILDING OCCUPANCY: R-3/U
Comments: In addition to the above fee, an additional fee of $ is due ( hour @ $ /hr.) for the CalGreen review.
Sheet of
BUILDING
PORTION
Garage Convert
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
1997 UBC Building Permit Fee
-ri:':-J .%1.
1997 UBC Plan Check Fee
I /,".,,I %1.
Type of Review:
D Repetitive Fee ~j Repeats
AREA Valuation
( Sq. Ft.) Multiplier
216
By Ordinance
Complete Review
D Other
D Hour1y
EsGil Fee
Reg. VALUE ($)
Mod.
1 0,046
10,046
D Structural Only
ARCHITECTUAL CORRECTIONS
PROJECT:
HESS RESIDENCE
1540 Weatherly Rd.
Carlsbad, CA 92011
February 24, 2021
CORRECTION RESPONSES TO
ARCHITECTURAL COMMENTS
CORRECTION:
1.Acknowledge
2.Form 50-B submitted + Form B-55 added to TS Sheet
3.Name added to TS Sheet
4.Architect signature at top right corner of each sheet
5.Added gross floor areas of requested sections on TS Sheet
6.specification note added to A2 Sheet
7.door schedule fixed at A2 Sheet
8.added note specifying new raised floor at Sections.
9.added note to MEP sheet
10.added note to MEP sheet
11.added note + fixed previous note to MEP sheet
12.added to GRN 1-2 sheets
13.added to GRN 1-2 sheets
14.added to GRN 1-2 sheets
15.added to GRN 1-2 sheets
16.added to GRN 1-2 sheets
17.added to GRN 1-2 sheets
18.added to GRN 1-2 sheets
19.added to GRN 1-2 sheets
20.added to GRN 1-2 sheets
21.added to GRN 1-2 sheets
22.added to GRN 1-2 sheets
23.added to GRN 1-2 sheets
24.added to GRN 1-2 sheets
25.added to GRN 1-2 sheets
26.added to GRN 1-2 sheets
27.added note to "MEP NOTES"
28.added to GRN 1-2 sheets
29.added to MEP Sheet
30.added to MEP Sheet
31.added to MEP Sheet
32.added to MEP Sheet
33.added to MEP Sheet
34.added to MEP Sheet
35.added to Window Schedule at A2
36.Acknowledge
37.no
38.Acknowledge
B-50 Page 1 of 6 Revised 08/19
Development Services
Building Division
1635 Faraday Avenue
(760)602-2719
www.carlsbadca.gov
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST B-50
PURPOSE
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances.
NOTE: The following type of permits are not required to fill out this form
Patio Decks PME (w/o panel upgrade)Pool
If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
an explanation must be provided to the satisfaction of the Building Official.
Details on CAP ordinance requirements are available on the city’s website.
A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be
completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and
download the latest form.
Applicant Signature: ___________________________________ Date: ___________________
Application Information
Project Name/Building Permit No.: BP No.:
Property Address/APN:
Applicant Name/Co.:
Applicant Address:
Contact Phone: Contact Email:
Contact information of person completing this checklist (if different than above):
Name: Contact Phone:
Company
name/address: Contact Email:
1540 Weatherly Rd., Carlsbad, CA 92011/ 215-072-09-00
02/25/2021
Thomas Zahn
Thomas_Zahn@hotmail.com619-940-2174
6591 Reflection Dr. #201, San Diego, CA 92124
Hess Residence - Garage Conversion CBR2020-3049
C cityof
Carlsbad
I I I
City of Carlsbad Climate Action Plan Consistency Checklist
Updated 8/15/2019 2
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet.
Building Permit Valuation (BPV) from worksheet: $_______________
Construction Type Complete Section(s) Notes:
Residential Low-rise High-rise A high-rise residential building is 4 or more stories, including a mixed-use building in which at least 20% of its conditioned floor area is residential use
☐ New construction 2A, 3A, 4A 1B, 2B, 3B, 4A
☐ Additions and alterations:
☐ BPV < $60,000 N/A N/A All residential additions and alterations
☐ BPV ≥ $60,000
☐ Electrical service panel upgrade only 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages only
☐ BPV ≥ $200,000 1A, 4A* 1B, 4A* *Multi-family dwellings only where interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed
Nonresidential
☐ New construction 1B, 2B, 3B, 4B and 5
☐ Alterations:
☐ BPV ≥ $200,000 or additions ≥ 1,000 square feet 1B, 5
☐ BPV ≥ $1,000,000 1B, 2B, 5 Building alterations of ≥ 75% existing gross floor area
☐ ≥ 2,000 sq. ft. new roof addition 2B, 5 1B also applies if BPV ≥ $200,000
CAP Ordinance Compliance
Checklist Item
Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary.
1. Energy Efficiency
Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section.
A. Residential addition or alteration ≥ $60,000 building permit valuation.
See CMC section 18.30.190.
☐ N/A _______________________________ ☐ Exception: Home energy score ≥ 7
(attach certification)
Year Built Single-family Requirements Multi-family Requirements
☐ Before 1978 Select one: ☐ Duct sealing ☐ Attic insulation ☐ Cool roof ☐ Attic insulation
☐ 1978 and later Select one: ☐ Lighting package ☐ Water heating Package
☐ Between 1978 and 1991 Select one: ☐ Duct sealing ☐ Attic insulation ☐ Cool roof
☐ 1992 and later Select one: ☐ Lighting package ☐ Water heating package
B. Nonresidential* new construction or alterations ≥ $200,000 building permit valuation,
or additions ≥ 1,000 square feet.
☐ N/A _______________________________
30,000.00
I
~
X
X
□ I
□
□
City of Carlsbad Climate Action Plan Consistency Checklist
Updated 8/15/2019 3
See CMC 18.21.155 and CALGreen Appendix A5, Division A5.2 – Energy Efficiency.
A5.203.1.1 Choose one: ☐ .1 Outdoor lighting ☐ .2 Warehouse dock seal doors ☐ .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) ☐ .4 Daylight design PAFs ☐ .5 Exhaust air heat recovery
☐ N/A _______________________________
A5.203.1.2.1
Choose one as applicable: ☐ .95 Energy budget ☐ .90 Energy budget
☐ N/A _______________________________
A5.211.1** ☐ On-site renewable energy
☐ N/A _______________________________
A5.211.3** ☐ Green power (if offered by local utility provider, 50% minimum renewable sources)
☐ N/A _______________________________
A5.212.1 ☐ Elevators and escalators
☐ N/A _____________________________
A5.213.1 ☐ Steel framing
☐ N/A _____________________________
* Includes hotels/motels and high-rise residential buildings
** For alterations ≥ $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply
with CMC 18.30.130 instead.
2. Photovoltaic Systems
A. Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (2B below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(B) (high-rise residential) or 18.30.170(B) (low-rise residential), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional sheets if necessary) CFA #d.u. Calculated kWdc* Exception
☐ __________________________________
☐ ______________________________________________
☐ ______________________________________________
☐ ______________________________________________
Total System Size: kWdc
kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain.
B. Nonresidential new construction or alterations ≥$1,000,000 BPV and affecting ≥75% existing floor area, or addition that increases roof
area by ≥2,000 square feet. Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings.
Choose one of the following methods:
☐ Gross Floor Area (GFA) Method
GFA: __________________ Min. System Size: ______ kWdc
☐ If < 10,000s.f. Enter: 5 kWdc
☐ If ≥ 10,000s.f. calculate: 15 kWdc x (GFA/10,000) **
**Round building size factor to nearest tenth, and round system size to nearest whole number.
☐ Time- Dependent Valuation Method
□
□
City of Carlsbad Climate Action Plan Consistency Checklist
Updated 8/15/2019 4
Annual TDV Energy use:*** ______________ x .80= Min. system size: ____________ kWdc
***Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A. Residential and hotel/motel new construction
Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section.
☐ For systems serving individual dwelling units choose one:
☐ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) ☐ Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) ☐ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher ☐ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors ☐ Exception: ______________________________________________________________________________
☐ For systems serving multiple dwelling units, install a central water-heating system with all of the following:
☐ Gas or propane water heating system ☐ Recirculation system per CMC 18.30.150(B) (high-rise residential, hotel/motel) or CMC 18.30.170(B) (low-
rise residential) ☐ Solar water heating system that is either: ☐ .20 solar savings fraction ☐ .15 solar savings fraction, plus drain water heat recovery ☐ Exception: ______________________________________________________________________________________
B. Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section.
☐ Water heating system derives at least 40% of its energy from one of the following (attach documentation):
☐ Solar-thermal ☐ Photovoltaics ☐ Recovered energy
☐ Water heating system is (choose one): ☐ Heat pump water heater ☐ Electric resistance water heater(s) ☐Solar water heating system with .40 solar savings fraction ☐ Exception: ______________________________________________________________________________________
□
□
City of Carlsbad Climate Action Plan Consistency Checklist
Updated 8/15/2019 5
Calculations: Total EVSE spaces = .10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces – EVSE Installed (EVSE other may be “Capable,” “Ready” or “Installed.”)
*Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ≥ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit
valuation ≥ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed.
B. Nonresidential new construction (includes hotels/motels) ☐ Exception : ______________________________
Total Parking Spaces Proposed EVSE Spaces
Capable Ready Installed Total
Calculation: Refer to the table below:
Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces ☐ 0-9 1 1 ☐ 10-25 2 1 ☐ 26-50 4 2 ☐ 51-75 6 3 ☐ 76-100 9 5 ☐ 101-150 12 6 ☐ 151-200 17 9 ☐ 201 and over 10 percent of total 50 percent of Required EV Spaces
4. Electric Vehicle Charging
A. Residential New construction and major alterations*
Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. ☐ One and two-family residential dwelling or townhouse with attached garage: ☐ One EVSE Ready parking space required ☐ Exception : _______________________________
☐ Multi-family residential: ☐ Exception : ______________________________ Total Parking Spaces
Proposed EVSE Spaces
Capable Ready Installed Total
□
□
City of Carlsbad Climate Action Plan Consistency Checklist
Updated 8/15/2019 6
An approved Transportation Demand Management (TDM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TDM is applicable to your permit, staff will contact the applicant to develop a site-specific TDM plan based on the permit details.
Employee ADT Estimation for Various Commercial Uses
Use
Emp ADT for
first 1,000 s.f.
Emp ADT/
1000 s.f.1
Office (all)2 20 13
Restaurant 11 11
Retail3 8 4.5
Industrial 4 3.5
Manufacturing 4 3
Warehousing 4 1
1 Unless otherwise noted, rates estimated from ITE Trip Generation Manual, 10thEdition
2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc.
Other commercial uses may be subject to special consideration
Sample calculations:
Office: 20,450 sf
1. 20,450 sf / 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf = 8 ADT
2. 9,334 sf - 1,000 sf = 8,334 sf
3. (8,334 sf / 1,000 x 4.5) + 8 = 46 Employee ADT
Acknowledgment: I acknowledge that the plans submitted may be subject to the City of Carlsbad’s Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TDM plan and understand that an approved TDM plan is a condition of permit issuance. Applicant Signature: ______________________________________________________ Date: ___________________
Person other than Applicant to be contacted for TDM compliance (if applicable): Name (Printed): _________________________________________________________ Phone Number: ________________ Email Address: _________________________________________________________
5. Transportation Demand Management (TDM): Nonresidential ONLY □