Loading...
HomeMy WebLinkAboutCT 02-15; BRESSI RANCH MASTER TENTATIVE MAP PA 1-5; Tentative Map ExhibitBRESSI RANCH MASTER TENTATIVE MAP PLANNING AREAS 1 THROUGH 5 .Project Site I ~\ \\ \\ \\ \\ BRESSI RANCH MASTER TENTA nVE MAP CT 00-06 PALOMAR SUBDIVISION BOUNDARY _j MfLROSE DRIVE POINSEmA LANE VICNITY MAP ~ II N • - 0 TRAFFIC SIGNAL NOTE NO SCALE 0 j ' / FUTIJ/?E mAmc SIGNALS ARE SHOWN ON THIS SHEET FOR PLANNING PURPOSES ONLY. mAmc SIGNALS lt!LL BE DfSIGNED CONCURRENT WITH NEIGHBORHOOD DEVELOPMENT. INSTALLATION WILL OCCUR 141/EN DIRECTED BY THE CITY ENGINEER. l: \t"ngr \2268\ 7M-IND\??6i?TA1-i'ND0!.dwg .12,/03/2003 C'8.' 48: 28 AM .1-•s7 VJLLAeEB OF LA COSTA THE eREENB er BFJ-,08 NOTE RIGHT IN RIGHT OUT ONLY ACCESS RIGHTS HA VE BEEN WAIVED ALONG fL CAMINO REAL, PALOMAR AIRPORT ROAD, AND fL FUERTE S7REET. EXCEPT AS SPECIF/CALLY SHOWN ON THIS TENTATIVE MAP. OTHER POINTS OF ACCESS ( *) SHALL BE RES7RICTED TO LOCATIONS SHOWN EXCEPT AS MODIFIED AND APPROVED BY THE CITY ENGINEER AND Pl.ANNING DIRECTOR USING THE SUBSTANTIAL CONFORMANCE PROCESS. SI EET INDEX MAP SCALE: 1 • = 400' CD SHEET NUMBER 81 l2_j EXISTING TRAffiC SIGNAL [§] PROPOSED/MOOIFIED TRAffiC SIGNAL [>(_)<l EXISTING RR£ HYDRANT .... PROPOSED RRE HYDRANT l1TILIT1ES WATER--------------CITY OF CARLSBAD SEWER--------------C/TY OF CARLSBAD STORM DRAIN---------CITY OF CARLSBAD GAS AND ELECTRIC------SAN DIEGO GAS .t ELECTl?IC TELEPHONE-----------SBC CABLE T.V.-----------ADELPHIA CABLE CT 02-15 LEGAL DESCRIPTION GENEl?AL AMERICAN Uff INSURANCE: c/o CONNING ASSET MANAGEMENT - LOT 1 THRU 5 PER FINAL MAP No. 14600 RECORDED MAY 29, 200J. ASSESSOR'S PARCEL NO. 2/J-OJ0-17 NPDES / SWPP NOTE: ALL LOTS WITHIN THIS SUBDIVISION SHALL PROVIDE STORM WATER RLTRATION (ONSITE) AS IDENTIFIED IN PRELIMINARY SWPPP DA TEO: JANUARY 2003. PRELMINARY SOILS REPORT BY: LEIGHTON AND ASSOCIATES. INC. DATED JULY 29, 1997 BENCHMARK DESCRIPTION: BRASS DISK IN CONCRETE IN A STANDARD SURVEY MEl.L ON ON CENTERUNE OF EL CAMINO REAL LOCATION: COUNTY OF SAN 0/EGO_jJ_ENCHMARK DESIGNATION NO. R1800 288+89EC ELEVA 110N: 311.407 M.S.L. DATUM: N.G.V.D. 29 --"=='-=----- LEGEND TENTATIVE MAP BOUNDARY. SUBDIVISION BOUNDARY. LOT UNE .......................... . ------ EXISTING CONTOURS. . . . . . . . . . . . . . --~-J10--- PROPOSED CONTOURS ..................... ----950--- SLOPE. SEllf'R MAIN/ MANHOLE . STORM DRAIN & CLEANOUT OR INLtT. WATER MAIN .... RECLAIMED WATER MAIN . Fl/?£ HYDRANT . . . . _ . . DA 'rtlGHT LINE BROW DITCH .. EARTHEN SWALE. . . . STl?EET LIGHT . . . . . LOT NUMBER ACCESS POINT. GENERAL NOTES 1. FOR EXISTING ZONING SEE SHEET 2. 2. FOR PROPOSED ZONING SEE SHEET 2. I" ; RW --l - 3. PROPOSED PROJECT IS LOCATED IN LOCAL FACIUTTES MANAGEMENT PLAN ZONE 17. 4. TOTAL AREA lt!THIN THE BRESSI RANCH INDUS7RIAL SUBDIVISION BOUNDARY CT 02-15 IS 129.2 ACRES. 5. EASEMENTS ARE AS SHOWN UNLESS OTHERWISE NOTED (SEE SHEET 2). 6. CUT AND FILL SLOPES ARE 2: 1; INTERNAL SLOPES VARY FROM 2.5: 1 TO 2: 1 7. GRADING SHOWN HEREON IS PRELIMINARY AND IS SUBJfCT TO MINOR REVISIONS MADE DURING THE ANAL DESIGN PROCESS. IN ACCORDANCE WITH APPROVAL FROM THE CITY ENGINEER AND PLANNING DIRECTOR. 8. MANUFACTURED SLOPES LOCATED IN AREAS TRANSITIONING TO NATURAL OPEN SPACE SHALL BE CONTOUR GRADED TO BLEND WITH NATURAL TERRAIN. 9. ALL LOT DIMENSIONS SHOWN ARE APPROX/MA TE. ALL LOTS TO MEET MINIMUM DIMENSIONS OF UNDERLINE ZONING. 10. SCHOOL DISTRICT: CARLSBAD UN/RED SCHOOL DISTRICT. 11. GEOMETRIC EARTHWORK QUANTITIES: EXISTING GRADING PER THE BRESSI RANCH MASS GRADING PLANS CT 00-06, DIM,. NO. 400-BA. ON-SITE GRADING QUANTITIES: FILL 15, 000 C. Y. CUT 15,000 C. Y. EXPORT /II.IPOR T . . O C. Y. 12. THE BEARINGS AND DISTANCES SHOWN r.fRE DETERMINED FROM A FIELD SURVEY. 13. TOTAL NO. OF INDUS7RIAL LOTS IS 40. BASIS OF BEAR!~ THE BASIS OF BEARINGS FOR THIS TENTATIVE 1./AP IS THE CALIFORNIA COORDINATE SYSTEI.I, NAO BJ, ZONE 6 AND WAS ESTABLISHED BETWEEN STA 110N NO. V-2002 PER R. D.S. 14023 AND STA 110N NO. SDGPS-41 ESTABLISHED BY THE COUNTY OF SAN DIEGO PER SAN DIEGO COUNTY HORIZONTAL CONTROL BOOK, I.E., N8B'54'os·w THE COMBINED SCALE FACTOR AT STA 110N V-2002 IS 0.999944419. GRID DISTANCE=GROUND DISTANC£ X COI.IBINEO SCALE FACTOR. ALL MEASURED DISTANCES SHOWN HEREON ARE GROUND DISTANCES. THE MAPPING ANGLE AT STATTON V-2002 IS -0"32'51.881" QUOTED BEARINGS FROM REFERENCE MAPS/DEEDS MAY OR MAY NOT BE IN TERMS OF SAID SYSTEM. APPLICATION NO. TrNTA TIVE 111ACT MAP. CT 02-15 OWNER / SUBDMDER NAME: GEN!:RAL AI./ERICAN LIFE INSURANCE CDMPANY, A MISSOURI CORPORATION, AS DMIER ADDRESS: PHONE: JJJ SOIJ11/ HOPE STREET /2950 LOS ANGElES. CA 90071 (2/J) 625-3700 BY: M£TROP()UTAN LIFE INSURANCE CO A NEW YORI< CORP. J\· It BY:'-/,, ··-../ fv 1,, --,0 )"\ 111l.E: ' ".11 • e , \'ls{ " >-0:, SHEET 1 OF 6 i L.,j t.5 o:' ln r R/W 1 '6' R/W 6J' 6J' 10' 44' g• g' 44' 5.5' 4.5 ~-hJ.r-- , •. '~.7; L---:=::: =::: ~ ::1 t: == == ==:::::: -I '.':-j·· EX IMPROVEMENTS ..:z_y,-, :---------> --::. ' -~ 1 • P.C.C. SIDEWALK PER D~. NO. J70-2 \x IMPROVEMENTS PER D~. NO. Jl0-2 R/W EXISTING PALOMAR AIRPORT ROAD PER DWG NO. 400-BH TYPICAL SECTION NO SCALE 1J6' 6J' 7J' 10' 44' 9' 9' 54' 10' R/W 5.5' 4.5 '--,7"\•:::~-.-;:::;:r ....,,._ -·-.: '-r--==========:j t: ______ v-/-.-r----'• / V 4• P. OVEMENTS ... ~ EX. IMPR ~ C.C. SIDEWALK \EX IMPROVEMENTS PER DWG. ND. J70-2 PER D~. NO. J70-2 EXISTING PALOMAR AIRPORT ROAD PER DWG NO. 400-BH STA. 142+35.24 TO 143+29.40 TYPICAL SECTION NO SCALE R/W 1. 6' R/W 6J' 6J' 10' 44' 9' 9' 44' 10' 14' 5.5' 4• P.C.C. Sf 'EWALK- --"":'".~,9 t_==== ~~ -· -=--:j • R/W L;, • ----. ~ . ,, ,· .. . .. STRUCnJRAL SECTION PER CITY OF CARLSBAD STANDARD SPECIF/CATIONS • ' ' 6 TYPE G CURB d< GUTTER EXISTING EL CAMINO REAL PER DWG. NO. 400-BG TYPICAL SECTION NO SCALE 104 52' 52' 10' 42' 42' 10 4.5' R/W 4.5' 5.5' 5.5' 4.5' FIRE H'rTJf/ANT AS SHOWN ON PLANS (TYP.) DRY UTILITY TRENCH~:, . LOCATIONS PER DRY ' UTILITY PLANS 4• P.C.C. SIDEWALK 6" TYPE "G" CURB -----< d< GUTTER STRUCTURAL SECTION PER CITY OF CARLSBAD STANOARD SPECIF/CATIONS WA TER llfC'iClEI) WATER EXISTING EL FUERTE STREET PER DWG. No. 400-8E R/W J5' o· TYPICAL SECTION NO SCALE 70' 25' J5' 2J' 12' R/W sma:r UGHT .AS SI/OWN ON PU.NS (TYP.) FIRE H'rTJf/ANT • ~Arsom,,r 4.5' 5.5' 6.5' 5.5' "'-"'-t-+-r"'"-:1--S1REET LIGHT TRUCnJRAL SECTION AS SHOWN Of/ ER CITY OF CARLSBAD PLANS (TYP.) FIRE H'rDRANT AS SHOl'/f,/ ON PLANS ( TYP.) TANDARD SPECIF/CATIONS FIRE H'rDRANT AS SHOWN Of/ PLANS (TYP.) 2X . ._, ,,,', ' DRY UTILITY TRENCfl~-~~ • .. LOCATIONS PER DRY UTILITY PLANS 4" P. C. C. SIDEWALK 6" TYPE •r;• CUR8 -----< &: GUTTER STORM NEC'((1£f) S l',f"R WA R DRAIN WATER EXISTING AL/CANTE ROAD PER DWG. No. 400-8B STA. 113+15.13 TO 119+71.73 TYPICAL SECTTON NO SCALE T: \Fngr \/?68 \ TM--IND \?/°6RTA1--IND02.dwq 72/C,3//003 OR: 52: 58 AM PST R/W 72' R/W J6' J6' 10' 26' 26' 10' 4.5' 4.5' F/11( H'rlJRANT ~ti:/,°'ffr,,°t TRUCnJRAL SECTION A R Cl TY OF CARLSBAD S ~NDARD SPECIF/CATIONS 2X 15. 1,...2!~J:,.-~ DRY UTILITY TRENCH~ LOCATIONS PER DRY UTILITY PLANS 4 • P. C. C. SIDEWALK NONCONTIGUOUS 6" TYPE "G" CUR8 ----i d< GUTTER WA7ER EXISTING TOWN GARDEN ROAD PER DWG. No. 400-8 STA. 1+88 TO 3+34.39 TYPICAL SECTION NO SCALE R/W 67.5' R/W J6' 10' 26' 4.5' 5.5' DRY UTILITY TRENCH . LOCATIONS PER DRY U TILi TY PLANS • FIRE HYDRANT AS SHOWN ON PLANS (TYP.) 1.5 26' 5.5 TRUCTURAL SECTION R CITY OF CARLSBAD TANOARO SPECIF/CATIONS 4 • P. C. C. SIDEWALK NONCONTIGUOUS +t---+-6" TYP. 6" TYPE "G" CURB-----< & GUTTER 0 STORM NfC'iClEI) S l',f"R WA R DRAIN WATER EXISTING TOWN GARDEN ROAD PER DWG. No. 400-8 STA. 7+39.39 to 18+69.34 TYPICAL SECTION R/W 10' 4.5' J6' 5.5' FIRE H'rTJf/ANT AS SHOl'/f,/ ON PLANS ( TYP.) • 2X 4" P.C.C. SIDEWALK 6" TYPE "G" CURB-----< & GUTTER 26' STORM DRAIN NO SCAlE 72' J6' 26' TRUCnJRAL SECTION ER CITY OF CARLSBAO TANDARD SPECIF/CATIONS WiTER 5.5' EXISTING INNOVATION WAY PER DWG No. 400-8B R/W J6' TYPICAL SECTION NO SCALE 72' J6' 26' 26' 10 R/W 4.5' R/W 4.5' 5.5' 5.5' 4.5' FIRE H'rlJRANT AS SHO !11'1 Of/ PU.NS ( TYP.) 2X DRY UTILITY TRENCH > ,{., 'j~'.tji LOCATIONS PER DRY UTILITY PLANS 4 • P. C. C. SIDEWALK 6" TYPE "G" CURB----' &: GUTTER STORM DRAIN TRUCnJRAL SECTION ER CITY OF CARLSBAD TANDARD SPECIF/CATIONS ; bl WATER sma:r LIGHT AS SHOWN ON PU.NS (TYP.) FIRE HYDRANT ~fAfjJOffr,,f S1REET LIGHT AS SHOWN ON PLANS (TYP.) FIRE H'rDRANT ~A~om,, °1' STIIEET UGHT AS SHOIIH ON PLANS (TYP.) · FIRE HYDRANT AS SHOWN ON PLANS (TYP.) EXISTING AND PROPOSED GA 1EWA Y ROAD (EAST OF EL FUERTE) PER DWG. No. 400-8B TYPICAL SECTION NO SCALE EARTHWORK PLANNING CUT FILI. AREA 1 0 CY 0 CY 2 1000 CY 1000 CY J 1J,OOO CY 1J,OOO CY 4 500 CY 500 CY 5 500 CY 500 CY TOTAL 15,000 CY 15,000 CY EXISTING CONTOURS FROM MASS GRADING PLANS DWG. No. 400-88, DWG. NO. 400-BA LOT COUNT /DENSITY TOTAL GROSS PLANNING AREA LOT NO. 1 1 2 2-9 J 10-2J 4 24-J2 5 JJ-40 R/W J6' 10· 26' . ---------- 4.5' 5.5' AREA (AC.) 2.0 2J.2 41.2 JB.6 24.2 72' J6' 26' CY/AC 0 86 6J1 26 41 R/W 10' 5.5' 4.5' f--"'=+-+-+ TRUCTURAL SECTION sma:r LIGHT ~&m0m,, f . tr--FIRE H'rlJRANT ' AS SHOIIH ON / PLANS (TYP.) • 2: 1 MA!t>J~-j.ij2~~J R CITY OF CARLSBAD TANDARD SPECIFICATIONS .,,-FIRE HYDRANT ./ AS SHO'(IN Of/ PU.NS (rtP.) DRY UTILITY TRENCH---! ! LOCATIONS PER DRY UTILITY PLANS 4" P. C. C. SIDEWALK- 6" TYPE "G" CURB -----' &: GUTTER G) I STORM DRAIN ; bl WATER PROPOSED • A·. ·a·. ·c~ "D" STREE Is R/W J6' 4.5' TYPICAL SECTION NO SCALE 72' 26' R/W J6' 26' 10' 5.5' 4.5' f--"=+ __ _. 110~, TRUCnJRAL SECTION Cl TY OF CARLSBAD TANDARD SPECIF/CA TIONS /-I!!~btlffl/h PLANS (TYP.) ··-FIRE HYDRANT I AS SHOWN Of/ ;; Pl ANS ( TYP.) • 15. DRY UTILITY TRENCH-·----! . LOCATIONS PER DRY UTILITY PLANS 4" P. C. C. SIDEWALK -- 5• TYPE "G" CURB -----' & GUTTER STORM DRAIN ; bl WATER EXISTING GA 1EWAY ROAD +t-+-6" TYP. (WEST OF EL FUER1E) PER DWG. No. 400-8B TYPICAL SECTION NO SCALE ~ FIRE H'rlJRANT AS SHO'(IN ON PLANS (TYP.) FIRST AMERICAN TITLE INSURANCE CO. PRELIMINARY TITLE REPORT # 1126323-11 DATED MARCH 30, 2000 ITEM PURPOSE/ OWNER DOCUMENT DATE FACILITY @ PUBLIC ROAD COUNTY OF S BOOK 1068, PAGE 496 10/2/40 @ PUBLIC ROAD COUNTY OF S BOOK 1069, PAGE 456 10/2/40 @) TRANSMISSION GAS LINE SDGE F/P 1511772 7/27/60 (§ POWER/COMMUN/CATION CMIIO F/P 18JJ52 10/2J/61 @ ROAD/UTILITY xxxx MAP NO 176J xxxx @ ROAD d< UTILITIES WIEGLANDS F/P 7J-240587 8/27/lJ @) A'AATION COUNTY OF S F/P 84-132298 (:IP 87-472299 4/11/84 e'120/84 @ PUBLIC UTILITIES PAC BELL F /P 86-447581 10/6/86 @) TRAmc SIGNAL CITY OF F /P 86-5JOJ41 11/18/86 CARLSBAD @ PUBLIC UTILITIES SDGE F /P 87-42J709 7/28/87 @ SLOPE EASEMENT CITY OF F /P 87-482006 8/25/87 CARLSBAD @ ROADWAY CITY OF F /P 1992-0793169 12/10/92 CARLSBAD @ TEMr-CITY OF F /P 1992-079J170 12/10/92 CONSTRUCTION CARLSBAD @ s, v~•~ ,,wc.,'Tff5F/ CONTENANTAL F /P 1997-0096701 12/10/92 &: MAINTENANCE RANCH @ EASEMENT NUMBER AS INDICATED ON SHEETS 3 11-IROUGH 6 AU SIGHT DISTANCE CORRIDORS SHALL HA VE A MAX. OF JO" TALL VEGETATION, SLOPES, OR OBSIRUCTIDNS 1/' TYPICAL SIGHT DISTANCE CORRIDOR PROPOSED "A·, ·a~ ·c·, "D" STREE Is SIGHT DISTANCE DETAIL NO SCALE ALL SIGHT DISTANCE CORRIDORS SHALL HA VE TYPICAL SIGHT DISTANCE A MAX OF JO" TALL CORRIDOR VEGETATION, SLOPES, OR OBSTRUCTIONS / l \ 25 :p/P. -----.------,...----~ ~ - PROPOSED FUTURE DRIVEWA rs SIGHT DISTANCE DETAIL NO SCALE APPROVED I ~ ~ ~ a g a CO( ~ I § ~ :,e 1::j ~ S! -~~ :g "" <'i ~ ~ C, V) L,J tJ tt: ~ ~ ~ "' ~ ~ a; "" es a, :,.; ~ ~ a, ~ ~ i !..) ~~1 .. ,.. a, SHEET 20F6 "-' 4-.. b "') 0 • 50 100 200 .J 0 GRAPHICAL SCALE £:X/S11/1/G El CAM//1/0 R£:AL PER D~. NO. 400-BG T: \Cngr\2268\ TM-iN0 \2268TM---IND03.c!wg 03/08/2004 U/: !JL': J.1 liM PST SEE SHEET 4 ' \ ( to NOTE: ALL INDUSTRIAL DRIVEWAYS ( t) SHALL PROVIDE SIGHT DISTANCE LINES PER THE CITY OF CARLSBAD SIGHT DISTANCE CRITERIA AND CAL TRANS STANDARDS. WATER AND SEWER SERVICE LATERALS WILL BE PROVIDED AT DRIVEWAY LOCATIONS. EXISTING MASS GRADING PER DWG NO. 400-BA. EXISTING IMPROVEMENTS PER DWG. NO. 400-8, 400-BB, AND 400-BG TEMPORARY DESILTATION BASINS ARE ALSO FEASIBLE SITES FOR STORM WATER POLUTANT BASINS TO BE CONSTRUCTED CONCURRENT WITH DEVELOPMENT OF EACH LOT. APPROVED -----•♦•' SHEET 30F6 lo ---.-l.- 0 50 100 200 300 GRAPHICAL SCALE T.· \E_ngr \2268 \ TM-IND \2268TM-IND04.dwg 03/08/2004 07: 53: 16 AM !'ST \ I \ I \. \ ' I I 0 0--" 0 6) SHEET 3 "-I" <( lll cc ---, c:.o ~ <( 0 l 0 ~ f2) 0 L ~ r ~ L'J lli z -~ :z: Cl) <( -l Q APPROVED 311 NOTE: ALL INDUSTRIAL DRIVEWAYS ( t) SHALL PROVIDE SIGHT DISTANCE LINES PER THE CITY OF CARLSBAD SIGHT DISTANCE CRITERIA AND CAL TRANS STANDARDS. WATER AND SEWER SERVICE LATERALS WILL 8£ PROVIDED AT DRIVEWAY LOCATIONS. EXISTING MASS GRADING PER DWG NO. 400-8A. EXISTING IMPROVEMENTS PER DWG. NO. 400-8, 400-88, AND 400-8G TEMPORARY DESIL TA TION BASINS ARE ALSO FEASIBLE SITES FOR STORM WATER POLUTANT BASINS TO BE CONSTRUCTED CONCURRENT WITH DEVELOPMENT OF EACH LOT. § ~ I L SHEET 40F6 -~ ~ lJ <..l 0: ti> I ::ii If) ' - (f) <( lll cc <( (2) z ~ ~ lli CJl z ~ z ~ <( -l CL, .--., to 0 l 0 0 r l,') ~ .. >~ ". . ~~ ; =~ ;:; 1· ~~:,z ___ :5' . ,~c.-•••_s3,:,,q~~ s·:2> 93 (G) 71 (N) \ · • · rt . 1 ··... \ J7A . \ ·... , A-1sys•-u~ . .. · , '.: , , , PL J~\ J\J J\J J J\J G ~t\ RE J-\ -J 5 [ C -r O O ~ 0 E>) T: \[flgr \2268\ T.V-/ND \2268 TM lN[H.).'J. 'Jwg U-5/J8/?0U4 UI: 56: 50 AM PST 0 50 100 200 300 GRAPHICAL SCALE I lQ lli CJl APPROVED NOTE: ALL INDUSTRIAL DRIV[WA YS ( t) SHALL PROVIDE SIGHT DISTANCE LINES PER TH£ CITY OF CARLSBAD SIGHT DISTANCE CRITERIA AND CAL TRANS STANDARDS. WATER AND SEWER SERVICE LATERALS WILL BE PROVIDED AT DRIVEWAY LOCATIONS. EXISTING MASS GRADING PER DWG NO. 400-8A. EXISTING IMPROVEMENTS PER DWG. NO. 400-8, 400-88, AND 400-8G TEMPORARY DESILTA TION BASINS ARE ALSO FEASIBLE SITES FOR STORM WATER POLUTANT BASINS TO BE CONSTRUCTED CONCURRENT WITH DEVELOPMENT OF EACH LOT. .. >-"' SHEET 50F6 '9 <+ 0 --e Qt lo .... I- Ill i - ll.. <II ::r; '<I;~ V l.c) :.: ~~ -~ <::,,: lu ">\!:> N --:z: V) I--() Ill ~ 2: I-.... :.: ~ Qc ~ '-l en ~ n:'. lC) P L J-\ J\J J\J J J\J G -J ;I -j' ( c-r o o~ o B) NOTE: PLANNING AREA 14 TO BE DEVELOPED AND IMPROVED PER SEPARATE PERMIT APPL/CATION. T: \[n9r\2268\TM-iND\22687M--iN006.awg 03/08/2]04 07:57:32 AM PSl ~ ,11 N-~ &l 0 50 100 200 300 GRAPHICAL SCALE ;( ; ; ,' OP EJ\J f') 0 APPROVED (c-r oo~cJfJl --GATEWAY ROAD TO BE EXTENDED TO PALOMAR AIRPORT ROAD. EXISTING CUL-DE-SAC ANO UTILITIES PER owe NO. 400-88 TO BE MODIFIED PER CONSTRUCTION CHANGE. NOTE: ALL INDUSTRIAL DRIVEWAYS ( i) SHALL PROVIDE SIGHT DISTANCE LINES PER THE CITY OF CARLSBAD SIGHT DISTANCE CRITERIA AND CAL TRANS STANDA'Ros. WATER AND SEWER SERVICE LATERALS WILL BE PROVIDED AT DRIVEWAY LOCATIONS. EXISTING MASS GRADING PER owe NO. 400-BA. EXISTING IMPROVEMENTS PER DWG. NO. 400-8, 400-88, AND 400-8G TEMPORARY DESILTA TION BASINS ARE ALSO FEASIBLE SITES FOR STORM WATER POLUTANT BASINS TO BE CONSTRUCTED CONCURRENT WITH DEVELOPMENT OF EACH LOT. SHEET 60F 6