HomeMy WebLinkAboutPS 2020-0065; WILDBIRD; Sign Permits/Programs (PS)C cityof
Carlsbad
_ VED
MAR 3 0 2020
CITY O~ vARLSBAD
PLANl\lil\JG DIVISION
REVIEW FOR
SIGN PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
PLANNING APP
REC'D BYr1.c:..-..i.~~-',,U.--'alt.lil\.-~=-=-==,__-
DATE SIGN F-E~E~'-"--+~"=0:=<'C)=--------
SIGN PROGRAM FEE ________ _
RECEIPT NO. -------------
NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602-
2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE*
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks
Name of Project: ~ommerce Cru:fBQ \JJ11J..b\t:A
Address of Project: 5205 5225 5235 5245 5315 5355 5365 5375 Avenida Encinas, Suite
Assessor Parcel Number: 210-090-41-00 ...=.. ................. ____ ........... _____________________ _
Related Planning Case Number(S): ____________________ _
TYPE OF DEVELOPMENT:
(a) Residential (d)
(b) Commercial ( e)
(c) Office/Industrial (f)
Hotel/Motel
Service Station
Prof. Care
(g) Theater
(h) Gov't/Church/School
(i) Public Park
0) Produce Stand
(k) Nursery
(I) P-U/OS Zone
SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes Ii] No □
Specific Plan Number PS2019-0111
VILLAGE REVIEW AREA (If yes, please complete information on page 3) Yes D No D
SOUTH CARLSBAD COASTAL REVIEW AREA Yes □ No □
SIGN ORDINANCE: Yes □ No □ COASTAL ZONE: Yes □ No □
P-11 Page 1 of 4 Rev. 02/28/18
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument
Wall 1 8 sf 24
Suspended/Projecting
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes □ No □ Date ______ _
PROPOSED PERMANENT SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER SIGN SIGN SIGN
ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT
Pole**
Monument**
Wall 1 7.' 7-l ,,~ l 7 1i
Suspended/Projecting
Directional
Canopy
Freestanding**
(Project Identity)
Digital Display
PROPOSED TEMPORARY SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER. PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Construction**
For Sale**
Banner
Interim
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-of-
way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required
for such proposed signs.
P-11 Page 2 of 4 Rev. 02/28/18
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
I I I I
P/L / Sipt :e• Requirement
Show buildina/1 I ;
I
J Show setbacks fram all earb1 ~---l ---
I I I I
I I I Show all property lines I
P/L : I
:/ I
earb tine i
----------~---
• •
Sipt Vuihility I Street Name(1) (i) I
I North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
Total Building Square Footage: 1 ~71(/ sq. ft.
Total Building Street Frontage: ----,.,9--"?,-=7,......--.t;"---linear ft.
Total Signage Allowance: --z. ) sq. ft.
Existing Signage (sq. ft.): IJ sq. ft.
Remaining Sign Allowance at Present: J -1 sq. ft.
Proposed Signage (sq. ft.): 7}: sq. ft.
Remaining Sign Allowance After Proposed Sign: ~ sq. ft.
VILLAGE REVIEW AREA
Total Signable Area: sq. ft. --------
Tot a I Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: inches
P-11 Page 3 of4 Rev. 02/28/18
PROPERTY OWNER APPLICANT
NAME PRINT OR TYPE NAME PRINT OR TYPE
CCC-Carlsbad, LLC Integrated Signs / Angela Moore
MAILING ADDRESS MAILING ADDRESS
236 S. Sierra Avenue 1160 Pioneer Way, Suite M
CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE
Solana Beach, CA 92075 619-876-6116 El Cajon CA 92020 619-733-1329
I CERTIFY THAT I AM THE LEGAL OWNER
AND J ALL THE ABOVE INFORMATION
IS UE ND CORRECT TO THE BEST OF
M KNO LEDGE.
angela@isasign.com
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
619-579-2229
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: ❖ In right-of-way ❖ In visibility triangle at corner
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When approved ?~1/
APPROVED: Planner:~~~.;.......;"-_,......,.~---------Date: 5MW
P-11 Page4 of4 Rev. 02/28/18
VICINITY MAP
PROPERTY OWNER:
Property Reserve Inc
5205 Avenida Encinas,
Carlsbad, CA 92008
TENANT:
Cruzan
5245 Avenida Encinas, Suite F
Carlsbad, CA 92008
LEGAL DESCRIPTION:
PAR 19TR 11457
LOT SIZE: 4.4 ACRES
MAP# PMl 1457
ZONING: M
LAND USE: LIGHT INDUSTRIAL
APN: 21 0-090-41-00
,,
\,
OMMER
5205. 5375 AVE. ENCINAS
DATE
·--==-5225 ;, "'=,:"'' 11251 SQ. FT . .,
H
5315
15.875SQ. FT.
A 5375 :
10.638SQ.FT.
B Jit
C 'Iii
C 5365
14.926SQ.FT.,
5355
J,. iM
I'
15,751 SQ. FT.
----7
I
Commerce
cruzan
Project location:
t No.: Projac
Sales man:
Dasig ner:
Date:
Ravi sion:
5205-5375 Avenida Encinitas
Carlsbad, CA 92008
200025-01
Curt Bauer
Angela M.
February 21, 2020
6 '------------
6 '-----------6, _________ _
6 , _________ _
6 '------------------
6 '------------6
~to,ner Ap!M'ovll: D1t1:
L 1ndlord APP".;..i]::;; ~3/18/2020 Date:
l'rhn~d Llndlord't N1m1:
Llndlord's l'tten• Hllfflller•
~ lnteg r!!,~BU§~~s,~
1160 Pioneer Way, Suite M, El Cajon, California 92020-~9~
T: 619.579.2229 I F: 619.579.7651 I isasign.com I Info@1sas1gn.com
ORIGINAL CONCEPT
I rated Signs and cannot be reproduced This design Is the exclusive prortpe'.1)'tho0u\ ~~:r prior written consent. In whole or pa w1
Scale:
As Noted
Sheet No.: 1 /4
TYPICAL ELEVATION -TENANT ID WALL SIGN LOCATION
SCALE: 1 /32'= 1 '--0'
19'-11 • SUITE H FRONTAGE
EQ EQ
16'-5" $
H
□
TYPICAL ELEVATIONS
SCALE: 1 /4" = 1 '-0"
19'-11 " SUITE F FRONTAGE
EQ EQ
® SEE SHEET 3 FOR
SIGN SPECIFICATIONS
16'·5" $
Commerce
cruzan
Project Location:
5205-5375 Avenida Encinitas
Carlsbad, CA 92008
ProjectNo.: 200025-01
Salesman: Curt Bauer
Designer: Angela M.
Date: February 21 , 2020
Scale: As Noted
Revision:
L
L
L
L
L
L
L
L
L
L
L
L
L
L
~ ~ ~
Integrated SIGN s
DREAM IT• BUILD IT• SIGN I T
1160 Pioneer Way, Suite M
El Cajon, California 92020-194
T: 619.579.2229 I F: 619.579.76
isasign.com I Info@isasign.co
4
51
m
ORIGINAL CONCEPT
This design Is the exclusive proper! y
of Integrated Signs and cannot be
reproduced In whole or part
without their prior written consent
SheatNo.: 2 /4
.
"'
¼" ¼" ... t .· ... . . . ..
...
SUITE ID SUITE ID
: .. ...
STAND-OFFS .·. -.. . ...
--. : .. TENANT PANEL .·.·.·. TENANT PANEL -.. ~ : .. ..
..... ~:,
:
.. . .
STAND-OFFS .. .....
..
NOTE: INSTALLED ON
ROCK WALL, LONGER : STAND-OFFS STUDS MIGHT BE -.. REQUIRED ·.
~¼"
:.· .... ·14-¼"
SECTION DETAIL -ROCK © SECTION DETAIL-CONCRETE
SCALE: 1 1 /'Z' = l '-0' SCALE: 1 1 /'Z' = 1 '-0'
.
N
62"
60"
42"
5½"
r-----------------------------,
L-----------------------------~
0
® QUANTITY: 49 I SIGN AREA: 7.1 SF EA
~----SUITE ID
PERMANENT BACKGROUND SIGN PANEL PAINTED TO MATCH
MATTHEWS MP 41335SP ANODIC BLACK (SATIN FINISH).
1/8" THK. ALUMINUM PANEL SECURED 1/4" AWAY FROM WALL
SURFACE WITH STAINLESS STEEL BACKPINS AND SILICONE ADHESIVE.
USE 1/4" DIAM. ALUMINUM SPACERS, PAINT FINISHED TO MATCH
ADJACENT WALL COLOR.
FONT FOR SUITE IDENTIFICATION= MYRIAD PRO BOLD.
~--TENANT PANEL
3MM ACM WHITE ALUMINUM SIGN PANEL PAINTED MATTHEWS
BRUSHED ALUMINUM W/ OPAQUE VINYL OVERLAY GRAPHICS.
Qllllt--------STAND-OFFS
•---------------•1-----------_. 3/4" DIAMETER STAINLESS STEEL STANDOFFS (SATIN FINISH) TO SECURE TENANT PANEL IN PLACE, 1/2" AWAY FROM SUITE ID SIGN PANEL FACE.
~ STANDOFFS SECURED TO WALL WITH STAINLESS STEEL HARDWARE AS
REQUIRED FOR WALL TYPE. STANDOFFS MUST REMAIN IN PLACE ON THE
WALL WHILE TENANT PANELS ARE BEING UPDATED OR REPLACED.
TENANT SUITE ID SIGN
SCALE: l" = l '-0"
....
D.C>1
D.02
D.03
D.G4
D.05
D.08
D.07
D.08
o.oe
D.10
D.11
D.12
D.13
D.14
D.15
D.18
D.17
D.18
D.19
D.20
D.21
D.22
D.23
D.24
D.25
D..28
D.27
D..28
D.211
D.30
D.31
D.32
D.33
D.34
D.31
D.31
D.37
D.31
D.311
D.40
D.41
D.42
D.43
D.44
DAS
D.48
D.47
D.48
D.48
,....Name llcll .....
Hera Hub 5205 A
Vacant 5205 C
MammaChia 5205 E
VantageVue 5205 F + Palomar Sign 5205 G
POI Coatings 5205 H
Zoot/Squadra 5205 J
~
Total Gym 5225 C
All Rat 5225 F
Kinnetic Labs 5225 H
MOVE 5245 H
Vacant 5245 G
Cruzan 5245 F
~
SOME 5245 E
SOAR 5245 D
Norden 5245 C
Eric Hall & Assoc 5245 A
Vacant 5235 A
Shootsta 5235 C -
Jeffrey Franc 5235 D -
Classic Flooring 5235 E
Suncoast 5235 F -Serrano Systems 5235 G
Solterra Lighting 5375 A
Carve 5375 B
City SC 5375 C --
Corinthian Trtle 5375 E
@work Personnel 5375 F
Hetherington Eng.
1 5365 I A
New West Designs 5365 B
Craig Coley 5365 C
Mr Tint 5365 D
Vacant 5365 E
Precision Medical 5365 F
Vacant 5365 G
Coast Sonic 5365 H
Motion Industries 5365 J --Teak & Deck 5355 111 --Vacant 5355 110
Performance Medical 5355 109
Greenleaf I 53551101
Engage Engineering 5355 106
Vacant 15355 105 ---+---
Highlights SD 5355 104
Wildbird 5355 103
Vacant 5355 100
ASI 5315 J 150
Golden Key 5315 130 -
5315 I 100 Girl Scouts
Commerce
cruzan
Project Location:
5205-53 75 Avenida Encinitas
Carlsbad, CA 92008
ProjectNo.: 200025-01
Salesman: Curt Bauer
Designar: Angela M.
Data: February 21, 2020
Scale: As Noted
Revision:
v~ ~/4
Integrated SIGNS
DREAM IT• BUILD IT • SIGN IT
1160 Pioneer Way, Suite M
El Cajon, California 92020-1944
T: 619.579.2229 I F: 619.579.7651
lsaslgn.com I Info @lsaslgn.com
ORIGINAL CONCEPT
This design Is the exclusive property
of Integrated Signs and cannot be
reproduced In whole or part
without their prior written consent.
Sheet Na.:
0
WI LDBI R
0
TENANT SUITE ID SIGN
SCALE: 1" = 1 '-0"
REPLACE EXISTING AT 5355-SUITE 103
® QUANTITY: 1 I SIGN AREA: 7.1 SF
SUITE ID
PERMANENT BACKGROUND SIGN PANEL PAINTED TO MATCH
MATTHEWS MP 41335SP ANODIC BLACK (SATIN FINISH).
1/8" THK. ALUMINUM PANEL SECURED 1/4" AWAY FROM WALL
SURFACE WITH STAINLESS STEEL BACKPINS AND SILICONE ADHESIVE.
USE 1/4" DIAM. ALUMINUM SPACERS, PAINT FINISHED TO MATCH
ADJACENT WALL COLOR.
FONT FOR SUITE IDENTIFICATION= MYRIAD PRO BOLD.
TENANT PANEL
3MM ACM WHITE ALUMINUM SIGN PANEL PAINTED MATTHEWS
BRUSHED ALUMINUM W/ 3M BLACK #7725-12 VINYL OVERLAY GRAPHICS
NOTE:
LOGO TO ALWAYS BE PLACED TO THE LEFT OF THE TENANT NAME. ALL
ELEMENTS TO BE CENTERED ON GRAPHICS PANEL. IF NO LOGO IS EXISTING
USE PROJECT FONT = FUTURA CONDENSED MEDIUM
STAND-OFFS
3/4" DIAMETER STAINLESS STEEL STANDOFFS (SATIN FINISH) TO SECURE
TENANT PANEL IN PLACE, 1/2" AWAY FROM SUITE ID SIGN PANEL FACE.
STANDOFFS SECURED TO WALL WITH STAINLESS STEEL HARDWARE AS
REQUIRED FOR WALL TYPE. STANDOFFS MUST REMAIN IN PLACE ON THE
WALL WHILE TENANT PANELS ARE BEING UPDATED OR REPLACED.
Commerce
cruzan
Projtct Locttion:
5205-5375 Avenida Encinitas
Carlsbad, CA 92008
ProjectNo.: 200025-01
Salesman: Curt Bauer
Designer: Angela M.
Dato: February 21 , 2020
Scala: As Noted
v~
~/4
Integrated SIGNS
DREAM IT• BUILD IT • SIGN IT
1160 Pioneer Way, Suite M
El Cajon, California 92020-1944
T: 619.579.2229 I F: 619.579.7651
lsasign.com I info @lsasign.com
ORIGINAL CONCEPT
This design is the exclusive property
of Integrated Signs and cannot be
reproduced In whole or part
without their prior written consent.
ShaatNo.: