Loading...
HomeMy WebLinkAbout1525 FARADAY AVE; 100; CBC2022-0292; PermitBuilding Permit Finaled (City of Carlsbad Commercial Permit Print Date: 09/26/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 1525 FARADAY AVE, # 100, CARLSBAD, CA 92008-7371 BLDG-Commercial Work Class: 2121302700 Track#: $2,400.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: 2.88KW ROOF MOUNT SOLAR -6 MODULES Property Owner: Cogen EMERALD LAKE CORPORATE CENTRE LP 1525 FARADAY AVE, # 100 CARLSBAD, CA 92008 FEE SB1473 -GREEN BUILDING STATE STANDARDS FEE SOLAR-COMMERCIAL: per kW STRONG MOTION -COMMERCIAL (SMIP) Total Fees: $619.67 Total Payments To Date: $619.67 Permit No: CBC2022-0292 Status: Closed -Finaled Applied: 08/12/2022 Issued: 08/16/2022 Finaled Close Out: 09/06/2022 Final Inspection: 09/06/2022 INSPECTOR: Alvarado, Tony Contractor: HOME ENERGY SYSTEMS INC 9085 AERO DR, #STEA SAN DIEGO, CA 92123-2377 (619) 692-2015 Balance Due: AMOUNT $1.00 $618.00 $0.67 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov > ( City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan CheckOt:c.zpc:z._-Qz:::lZ Est. Value PC Deposit Date 2:)-1Z,,-2Z-- Job Address 1525 FARADAY AVE STE 100, CARLSBAD, CA 92008 Unit: APN:212-13-027 ·------' CT/Project #:. _________________ Lot #:. ____ Year Built: ________ _ BRIEF DESCRIPTION OF WORK:NEW 2.88KW ROOF MOUBNT PV SYS W/ 6 MODS, 1 INV, 6 OPTIMIZERS 0 New SF : Living SF, ____ Deck SF, ___ Patio SF, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YO N , if yes how many? ___ _ D Remodel: _____ SF of affected area Is the area a conversion or change of use? 0 YO N □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ___________ _ 0 Solar: 2·88 KW, 6 Modules, Mounted:0Roof O Ground, Tilt: 0 Y () N, RMA: 0 YO N, Battery:OVO N, Panel Upgrade: Ov ON Electric Meter number: ___________ _ Other: APPLICANT (PRIMARY CONTACT) Name: LINDSAY GRIMSHAW PROPERTY OWNER Name: EMERALD LAKE Address: 10769 WOODSIDE AVE SANTEE CA 92071 Address: 1525 FARADAY AVE STE 100, CARLSBAD, CA 92008 City: __________ State: ___ .Zip: ____ City: _________ State: ___ Zip:. ____ _ Phone:8082864939 Phone: 619 692 2015 Email:LINDSAY GRIMSAHW Email: LINDSAY@DESIGNS.SOLAR DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name:. _________________ Business Name:._H_E_S_S_O_LA_R ___________ _ Address: Address:9085 AERO DR #A, SAN DIEGO, CA 92123 City:. _______ State:. ___ Zip:.____ City:. ______ State:. ___ Zip:. ______ _ Phone: Phone: 619 692 2015 Email: Email: LINDSAY@DES IGNS.SOLAR Architect State License: __________ _ CSLB license #:800657 Class: ·------·------- Carlsbad Business License # (Required): _______ _ APPL/ CANT CERT/ Fl CATION: I certify that I have read the application and state that the above information is correct and that the information of tht plans is accurate. I agree to comply with all City ordinances and State laws relating ta building construction. NAME (PRINT): LINDSAY GRIMSHAW SIGN:LINDSAY GRIMSHAW DATE: 08/11/2022 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov REV. 04122 , Tt,\IS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaf firm under penal tyof perjury that I am licensed under provisions of Chapter9 ( commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the following declarations (CHOOSE ONE): DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Policy No. _________________________________________ _ -OR- DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: _E_M_PL_o_v_E_E_s_v_c_G_R_o_u_P ________________ 1 Policy No. wc1011as104 Expiration Date: -----------------1 -OR- D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, Interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work t his permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ______________________ lender's Address: _____________________ _ CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): LINDSAY GRIMSHAW SIGNATURE:LINDSAY GRIMSHAW DATE:8/11/22 Note: If the person signing above Is an authorized agent for the contractor (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do t he work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provid,d that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR- D I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, D FORM 8-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, Is available upon request when this application Is submitted or at the following Web site: http: I lwww.leginfo.ca.gov/ ca/aw.html. OWNER CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans Inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application Is based on the premise that the submitted documents and plan, show the correct dimensions of; the property, bulldlncs, structures and their setbacks from property llnu and from one another; access roads/easements, and utilities. The exlstlnc and proposed use of each buildinc as stated Is true and correct; all easements and other encumbrance, to development have been accurately shown and labeled as well as all on-site 1radinlfsite pre,aratlon. All Improvements exlst1n1 on the property were completed In accordance with all rqulations In existence at the time of their construction, unless otherwise noted. Note: If the above Is an 1uthortnd -, 1nc1u4e form 1-621 owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442•339-2719 Email: 8ui1ding@carlsbadca.gov 2 ltEV. 04/22 Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for (CBC2022-0292} Permit Type: BLDG-Commercial Application Date: 08/12/2022 Owner: EMERALD LAKE CORPORATE CENTRE LP Work Class: Cogen Issue Date: 08/16/2022 Subdivision: CARLSBAD TCT#85-24 UNIT#05 Status: Closed -Finaled Expiration Date: 03/06/2023 IVR Number: 42622 Address: 1525 FARADAY AVE, # 100 CARLSBAD, CA 92008-7371 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 09/06/2022 09/06/2022 BLDG-35 Solar Panel 190519-2022 COMMENTS Passed Tony Alvarado Checklist Item BLDG-Building Deficiency Commercial Building, roof mounted, per engineered plans and detail specifications, (6)-qty. panel solar system-Approved. BLDG-Electric Meter Release 190901-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS Commercial Building, roof mounted, per engineered plans and detail specifications, (6)-qty. panel solar system-Approved. BLDG-Final Inspection 190520-2022 Passed Tony Alvarado Checklist Item BLDG-Structural Final BLDG-Electrical Final Monday, September 26, 2022 COMMENTS Commercial Building, roof mounted, per engineered plans and detail specifications, (6)-qty. panel solar system-Approved. Commercial Building, roof mounted, per engineered plans and detail specifications. (6)-qty. panel solar system-Approved. Complete Passed Yes Complete Passed Yes Complete Passed Yes Yes Page 1 of 1 I • _,,. -------------------------------------.. Orie2 Engineering Structural & Bridge Engineers 9750 Miramar Road, Suite 310 San Diego, CA 92126 Phone: (858) 335-7643 Structural Calculations PROJECT: Emerald Lake PV (Project# 249.002-22 ) CLIENT: HES DESIGNED BY: Orie2 -Structural Engineers ESY DATE: 8/9/22 CBC2022-0292 1525 FARADAY AVE #100 2.88KW ROOF MOUNT SOLAR -6 MODULES 2121302700 8/16/2022 CBC2022-0292 ' t t Orie2 Engineering Structural and Bridge Engineers -_,_ .l...----------~-----------1....J~ Project and Location: Scope: Emerald Lake PV Carlsbad, CA Orie2 Job No. 249.002-22 To provide a structural evaluation of the existing building roof system to verify the capacity to support weight of new solar panels. Note: By adding the solar panels on the roof, it would be virtually impossible for the roof to ever experience Live Load on top of the solar modules. To be conservative, the existing roof framing is checked against a total Dead Load of 19.0 psf (11 psf + 8.0 psf solar panel + rack & ballast weight) and 20 psf Live Load (reducible). Codes: California Building Code (2019 CBC) Design Criteria: Dead Loads: 8.0 psf max due to the weight of added solar panels, ballast blocks, and racking components. Wind Design Loading: Basic Wind Speed, V = 96 mph Exposure Category = B Existing Structure: The existing structure is approximately 180'-0" long by 160'-0" wide with 1-1/2" 18 gauge metal decking. The roofing and decking is supported by steel beams and steel girder beams. Solar Panel Rack System: The racking system by Unirac utilizes their roofmount RM10 racking system. The existing roof framing have been checked for a dead load of 8.0 psf for a fully ballasted system. Findings and Recommendations: 1. The existing roof framing members are okay to support the additional 8.0 psf weight of solar panels, support racks, ballast blocks, and components. 2. The existing building is okay to support the additional seismic mass of the solar system, as it is under the code required 10%. ORf! 2 Orie2 Engineering Structural & Bridge Engineers 9750 Miramar Road, Suite 310 San Diego, CA 92126 Structural Calculations -Table of Contents Emerald Lake PV Orie2 Job No. 249.002-22 1 . Design Criteria ............................................................................................... 1 -4 2. Building Summary, Loads, & Added Seismic Mass Analysis ........................ 5 -7 3. Wind Design ................................................................................................... 8 -9 4. Solar Module & Metal Deck Analysis .......................................................... 1 0 -13 5. Roof Framing Member Analysis .................................................................. 14 -25 8/9122~ 1 :24 PM ATC Hazards by Location A This is a beta release of the new ATC Hazards by Location website. Please ~ with feedback. 0 The ATC Hazards by l ocation website wiH not be updated to support ASCE 7-22. Fjnd out whv. L\TC Hazards by Location Search Information Addreu: Coordinates: Elevation: Tlmestamp: 1525 Faraday Ave, Carlsbad, CA 92008, USA 33.136378, -117.2943851 145 f\ 2022-08-09T20:24 :26. 7692 Hazard Type: Seismic Reference Document: ASCE7-16 Risk Category: II Site Class: D-default Basic Parameters Name Value Description Ss 0.992 MCER ground motion (period=0.2s) S1 0.362 MCER ground motion (period=1.0s) St,.15 1.191 Site-modified spectral acceleration value St,.11 • null Site-modified spectral acceleration value Sos 0.794 Numeric seismic design value at 0.2s SA So1 • null Numeric seismic design value at 1 .Os SA • See Section 11.4.8 ..-Additional Information Name Value Description SDC • null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv • null Site amplification factor el 1 .Os CRs 0.898 Coefficient of risk (0.2s) CR1 0.909 Coefficient of risk (1.0s) PGA 0.434 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAt.4 0.521 Site modified peak ground acceleration TL 8 Long-period transition period (s) SsRT 0.992 Probabilistic risk-targeted ground motion (0.2s) SsUH 1.105 Factored unifonn-hazard spectral acceleration (2% probability of exceedance in 50 years) SsD 1.5 Factored deterministic •~lion value (0.21) S1"T 0.312 Probullall0 risk-targeled ground motion (1.0s) S1UH 0.318 Factored uniform.hazard spectral acceleration (2% probability of exc:eedenc» in 50 years) S1D 0.6 Fac:knd delelministic •~lion value (1 .0s) PGAd 0.5 Factored dei.rmlniltic a~tlon value (PGA) Page 1 http1:/lhazard1.atcouncil.org/#/aeismic?lat•33.136378&Ing--117 .2943851&addre11•1525 Faraday Ave•~2C Car1sbad%2C CA 92008%2C USA orrego ert• Park 1/2 I 8/9/22,, 1 :23 PM ATC Hazards by Location . A This is a beta release of the new ATC Hazards by location website. Please contact us with feedback. 4) The ATC Hazards by location website Will not be updated to support ASCE 7-22. Find out why, l\TC Hazards by Location Search Information Address: Coordinates: Elevation: Tlmestamp: Hazard Type: ASCE 7-16 1525 Faraday Ave. Cartsbad. CA 92008. USA 33.136378, -117.2943851 145 ft 2022-08-09T20:23:58.432Z Wind ASCE7-10 ASCE 7-05 Page2 orrego ert• Park MRI 10-Year 67 mph MRI 10-Year 72 mph ASCE 7-05 Wind Speed 85 mph MRI 25-Year 72 mph MRI 25-Year 79 mph MRI 50-Year 77 mph MRI SO-Year 85 mph MRI 100-Year 82 mph MRI 100-Year 91 mph Risk Category I 89 mph Risk Category I 100 mph Risk Category II 96 mph I Risk Category II 110 mph Risk Category Ill 102 mph Risk Category I11-IV 115 mph Risk Category IV 107 mph The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Please note that Iha ATC Hazards by Location website will not be updated to support ASCE 7-22. Find out why. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, Islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area -in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region boundaries, the resulting determination Is sensitive to rounding which may affect whether or not It Is considered to be within • Wind- borne debris region. Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented In the report should not be used or relied upon for any specific application without competent examination and verification of Its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the Information from this website assume all liabllity arising from such use. Use of the output of this website does not Imply approval by the govemint1 bullcllng code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. https://hazards.atcouncil.org/#/wind?latc:33.136378&lng"'-117 .2943851&address•1525 Faraday Ave%2C Car1sbad%2C CA 92008%2C USA 1/1 Page3 As-Built Roof Framing Plan D '\ (D.4 00 ii 00 00 ., .... 00 l , i .,._,. 4-~' ' 00 ., .... ~ ~r~~ • 00 .,._,. DO \ 00 DO 00 ~ • 00 .,,.... 11.¥.Fi 00 .2!L.. 11'1~ ., .... Approximate Location of Array B '.B.3. :B.7 C <t Q) 40'-0" c.D ~ X N ~ w ~ <( a:: LL BA - ~ W8x10 I W8x10 3 ~1 :. k 4~•~,,. X N ~I 0 w ~ <( a:: LL <.DI Approximate Location of Modules }t 2 W18 x40 40'-8" <t Q) W12x16 W12x16 c.D w ~ <( a:: LL W8x tr,</ .l( < < ~1 ~11 W18x40 c.D ~ X NBA ~ -3 I \ 40'-11'' DO w ~ ~ <( a:: LL DO ~1 $.___ ~Oo ~o ~ <lo ~~~ T . cv ~ ' Oo Oo Page 4 Orie. Eng,_,,. Structural & Bridge Engil'lflfKS 9750 Miramar Road, Suite 310 San Diego, CA 92126 Phone # : (858) 335-7643 Page 5 Project No.: 249.002-22 DATE : 08/11/22 PROJECT: Emerald Lake PV BY : ESY Building Summary: Building Information: Length, L: 180.00 ft (average) Width, W: 160.00 ft Parapet Height: 1.00 ft Roof Elevation: 15.00 ft (3rd story to roof -Roof elev = 40'-6") Roofing Type: TPO Membrane Roof Decking: 1-1/2' 18GA Metal Deck Roof Member: Trib: (ft) Span: (ft) Trlb. Area: (ftA2) W16x26 10.00 35.75 357.50 W14x22 8.61 30.00 258.30 W12x16 7.25 15.40 111.65 Wind Parameters: Exposure Category: B Basic Wind Speed, V: 96.0 mph Seismic Parameters: Mapped Short-Period Spectral Acceleration, Ss: 0.992 g Mapped One-Second Spectral Acceleration, 51: 0.362 g Short-Period Site Coefficient, Fa: 1.200 Long-Period Site Coefficient, Fv: 1.938 Roof Live Load: (psf) Wind Down: (psf) Check: 16.9 18.8 20.0 12.1 13.8 18.2 (ASCE 7-16, Section 26.7.3) (ASCE 7-16, Section 26.5.1) Okay Okay Okay (ASCE 7-16, Fig. 21-1 through Fig. 21-6) (ASCE 7-16, Fig. 21-1 through Fig. 21-6) (ASCE 7-16, Table 11.4-1) (ASCE 7-16, Table 11.4-2) Orie• Englnffrlng Structural & Bridge Engineers 9750 Miramar Road, Suite 310 San Diego, CA 92126 Phone # : {858) 335-7643 Project No.: 249.002-22 PROJECT: Emerald Lake PV Gravity Design Loads: Code: 2019 California Building Code (CBC) Roof Dead Loads: TPO Membrane 1-1/2" 18GA Metal Deck Insulation Ceiling Steel Beams Plumbing/Electrical/Mech\Misc Steel Girder Beams Total Total Roof Dead Load = 11.0 psf 1.0 psf 3.0 psf 1.0 psf 1.0 psf 3.0 psf 1.0 psf 10.0 psf 1.0 psf 11 .0 psf Solar Dead Load: 8.0 psf (Actual Max Array Area Load= 7.75 psf) Roof Live Loads: 2019 CBC, Section 1607 .11.2.1 Unreduced live Load, Lo: 20.0 psf Tributary Width: 10.0 ft Beam Span Length: 35.8 ft Roof Rise, F: 0.0 in/ per foot Tributary Area, At= 35.8 ft• 10.0 ft At = 357 .5 ft"2 Since 200.0 ft"2 < At = 357 .5 ft"2 < 600.0 ft"2, R 1 = 1.2 -0.001 * 357 .5 ft"2 R1 = 0.84 Since F = 0.0 in/ per foot<= 4.0, R2 = 1.00 R2= 1.00 Page6 DATE : 08/09/22 BY : ESY Reduced Roof live Load, Lr = Lo • R 1 • R2 = 20.0 psf • 0.8-4 • 1.00 (2019 CBC, Equation 16-26) Lr,. 16.9 psf Roof Live Load = 16.9 psf Wall Dead Loads: Metal Stud Walls = 15 psf (Assumed -conservative) Wall Dead Load= 15.0 psf Orie• E"fll,-lng Structural & Bridge Engineers 9750 Miramar Road, Suite 310 San Diego, CA 92126 Phone#: (858) 335-7643 Page7 Project No.: ___________ _ DA TE : 08/09/22 PROJECT: BY : ESY -------------- Check {El Building For Added Seismic Load of Solar System ect on states t at existing structure e ements carrying atera oa Is permItte to remain una ter given t at t e percent increase to that element does not exceed 10%. The critical element that experiences the highest percentage increase of the lateral load carrying system is the diaphragm. This analysis compares the seismic mass of the existing structure with the addition of Iha solar s stem to veri that the % increase to Iha dia hra m does not exceed the allowable 10%. Design Criteria: Total Seismic Mass of {El Buldlnq Lenglh, L: 180.00 ft Width, W: 160.00 ft Parapet Height Hp: 1.00 ft Roof Height H: 15.00 ft Roof Dead Load: 11.0 psf Wall Dead Load: 15.0 psf Seismic Mass of Roof, Wr = 11.0 psf • 180.00 ft• 160.00 ft Wr = 316800.0 lbs L = 180.00 ft L==II ==.JI! I W•160.00ft Hp"' 1.00 ft Seismic Mass of Walls, WI= 15.0 psf • [(15.0 ft/ 2) + 1.00 ft)• (2 • 160.00 ft ) WI = 40800.0 lbs H = 15.00 ft Total Seismic Mass of (E) Building, W = Wr +WI= 316800.0 lbs+ 40800.0 lbs W "' 357600.0 lbs Total Seismic Mass of Solar System Number of Solar Panel(s): 6 Panels Total Solar System Weight= 1963 lbs Wsz 1963.0 lbs Percent Increase in Building Seismic Mass Due to Addition of Solar System= Ws / W = 1963.0 lbs/ 357600.0 lbs Percent Increase in Building Seismic Mass Due to Addition of Solar System = 0.5% e ercent ncrease n u Per 2019 CEBC Section 502.5 [BS] 502.5 Existing structural elements carrying lateral load. Where the addition is structurally independent of the existing structure, existing lateral load-carrying structural ele- ments shall be permitted 10 remain unaltered. Where Lhe addi- tion is not structurally independent of the existing structure, the existing structure and its addition acting together as a sin- gle structure shall be shown to m eet the requirements of Sec- tions 1609 and I 613 of the California Building Code using full seismk forces. ay Exceptions: I . Any existing lateral load-carrying structural element whose demand-capacity ratio with the addition con- sidered is not more than 10 percent greater than its demand-capacity ratio with the addition ignored shall be permitted to remain unaltered. For purposes of calculating demand-capacity ratios. the demand shall consider applicable load combinations with design lateral loads or forces in accordance with Sections 1609 and 16 13 o f the California Building Code. Por purposes of this exception, comparisons of demand-capacity ratios and calculation o f design lateral loads, forces and capacities shall account for the cumulative effects of addi tions and alterations since original construction. Wind Design Example (W16x26) Page8 Oriez c,..,...,.19 Struciura/ & Bridge Engineers 9750 Miramar Road, Suite 310 San Diego, CA 92126 Phone# : (858) 335-7643 www.orie2.com Project No.: .::2:..:.49:..:..00=2·-=22=---------- Project : Emerald Lake PV BY : ESY ASCE 7-16 29.4.3: Rooftop Solar Panels w/ Flat/Gable/Hip Roofs w/ Slopes< 7° MWFRS -Other Structures -Rooftop Solar Panels Step 1: Determine risk category of building or other structure Risk Category =III I Table 1.5-1 Step 2: Determine the basic wind speed, V, for applicable risk category Wind Speed, V =196 1mph Figure 26.5-1A, B, C, orD Step 3: Determine wind load parameters: Wind Directionality factor, Kd =~0-.8,-5-~ Exposure Category = B I------< Topography factor, Kz1 = 1.00 Gust Effect factor, G = 0.85 Ground Elevation Factor, Ke = 1.00 Step 4: Determine velocity pressure exposure coefficient, K2 or Kh Height above ground level, z = ~ft Exposure coefficient, Kh = ~ Step 5: Determine velocity pressure, q2 or qh qh = 0.00256*Kh*Kz1*K/K/VL = 15.24 psf Step 6: Determine Net Pressure Coefficient, GCrn: 160.0 Building width, W5 = ft Building length, WL = ft 180.0 40.5 Roof height, h = ft 1.0 Parapet height, hp1 = ft 7.27 Panel length, Lp = ft 10.00 Tilt, w = deg Effective wind Area, A = ft' 357.50 2*h = 81 .0 ft Roof Zone = I 3 I- Nominal Net pressure Coeff, GCmnom = 0.827 - Yp = min(1.2, 0.9+hpifh) = 0.9 - Ye= max(0.6+0.06Lp, 0.8) = 1.0 - Ve (Uplift)=~- YE_ (?ownward) =~- Net Pressure Coefficient, GCm + = Yp Ye YE GCmnom = 0.792 Net Pressure Coefficient, GCm -= yP• y/yE*GCmnom = 1.189 Step 7: Calculate wind pressure to panels, p: P (+) = qh*(GCm) = P {·) • qh*(-GCm) = 12.1 psf -18.1 psf All Loads In Strength Value, multiply by 0.1 to get to ASO Design Value Section 26.6 and Table 26.6-1 Section 26. 7 Section 26.8 and Figure 26.8-1 Section 26. 11 Section 26.9 Table 26.10-1 Equation 26.10-1 s 35° Section 29.4.3 Figure 29.4-7 Figure 29.4-7 Section 29.4.3 Section 29.4.3 Section 29.4.3 Section 29.4.3 Eqn 29.4-6 Eqn 29.4-6 Eqn 29.4-5 Eqn 28.4-5 VE = 1 .5 for uplift loads YE = 1 .0 for downward loads Downward Wind Load Upward Wind Load Solar Module Wind Pressure Page9 Orie z EnglnNrlng Structural & Bridge Engineers 9750 Miramar Road, Suite 310 San Diego, CA 92126 Phone#: (858) 335-7643 www.orie2.com Project No.: _2_49_.00_2-_22 ________ _ Project : Emerald Lake PV BY : ESY ASCE 7-16 29.4.3: Rooftop Solar Panels w/ Flat/Gable/Hip Roofs w/ Slopes< 7° MWFRS -Other Structures -Rooftop Solar Panels Step 1: Determine risk category of building or other structure Risk Category =III I Table 1.5-1 Step 2: Determine the basic wind speed, V, for applicable risk category Wind Speed, V =196 1mph Figure 26.5-1A, B, C, or D Step 3: Determine wind load parameters: Wind Directionality factor, Kd = 0.85 1-------i Exposure Category = B Topography factor, Kzt = 1-1~.0-0---i Gust Effect factor, G = 0.85 Ground Elevation Factor, Ke = 1-1-.0-0---i Step 4: Determine velocity pressure exposure coefficient, K, or Kh Height above ground level, z =fil7ft Exposure coefficient, Kh =~ Step 5: Determine velocity pressure, q, or qh qh = 0.00256*Kh*K,t"K/K/VL = 15.24 psf Step 6: Determine Net Pressure Coefficient, GCm: Building width, W s = ft 160.0 Building length, WL = ft 180.0 40.5 Roof height, h = ft Parapet height, hp1 -ft 1.0 Panel length, LP = ft 7.27 10.00 Tilt, w == deg Effective wind Area, A = ~ 26.12 2*h = 81 .0 ft Roof Zone = I 3 I- Nominal Net pressure Coeff, GCmnom = 1.774 - Vp = min(1 .2, 0.9+hpi/h) = 0.9 - Ye= max(0.6+0.06Lp, 0.8) = 1.0 - Ve (Uplift)=~- Ve (?ownward) =~- Net Pressure Coefficient, GCm + -Vp Ve Ye GCmnom = 1.700 Net Pressure Coefficient, GCm -= Vp* Ve*Ve*GCmnom = 2.550 Step 7: Calculate wind pressure to panels, p: P (+} = qh*(GCm) = P (·) = qh*(-GCm} = 25.9 psf -38.9 psf All Loads In Strength Value, multlply by o.e to get to ASD Design Value Section 26.6 and Table 26.6-1 Section 26. 7 Section 26.8 and Figure 26.8-1 Section 26. 11 Section 26.9 Table 26. 10-1 Equation 26. 10-1 s 35° Section 29.4.3 Module Wind Area = 7 .267' x 3.425' = 26.12 ftA2 Figure 29.4-7 Figure 29.4-7 Section 29.4.3 Section 29.4.3 Section 29.4.3 Section 29.4.3 Eqn 29.4-6 Eqn 29.4-6 Eqn 29.4-5 Eqn 29.4-5 Ye = 1.5 for uplift loads Ve = 1 .0 for downward loads Downward Wind Load Upward Wind Load Orie~ Engl,-ing Structural & Bridge Engineer.; 9750 Miramar Rd., Suite 310 Phone t : (858) 335-7643 San Diego, CA 92126 www.orie2.com 2 PLANNING Project No. : 249.002-22 PROJECT: Emerald Lake PV Solar Module Check 2.3 MOUNTING OPTIONS Specifications Q.PEAK DUO X1.-G10.2 FB1 17.9 (454) 5400/3000 Q.PEAK DUO X1.-G10.c CUa 11.8 • 21.6 (300 • 550) 5400/2400 FB2 17.9 (454) 3600/3000 mFB2 17.9 (454) 3400/3000 CL3/mCL3 11.8 • 21.6 (300 -550) IP1 TB1b 28.1 (713) 3600/3000 TB2b Outer side: 28.1 (713) Inner side: 28.1 / 17.9 (713 / 454) CUb 11.8 • 21.6 (300 -550) 3000/2400 TB1a 35.8 (908) 2500/2400 Outer side: 35.8 (908) TB2a Inner side: 35.8/ 28.1/ 17.9 2700/2400 (908/713/ 454) P Wind Uplift on Solar Module= 0.6 x 38.9 psf = 23.4 psf (ASD) P allow module uplift = 0.020885 x 1,600 minimum = 33.42 psf P / P allow= 23.4 / 33.42 = 0.70 < 1.0 OKAY Page 10 DATE: 8/9/22 BY: ESY 3600/2000 3600/1600 2400/2000 2260/2000 2400/2000 1.5 2000/1600 1660/1600 1800/1600 o,,.z EltfllnNrlng Slructlnl & Bridge Engineers 9750 Miramar Rd, Suite 310 Phone I : (858) 335.7543 San Diego, CA 92126 www.orie2.com 1 2 1 2 P wind down = 25.9 psf Module Area = 26.12 ft"2 Project No. : 249.002-22 PROJECT : Emerald Lake PV Meta Deck Check 2 • Wind Load = 25.9 psf x 26.12 ft"2 = 677 lbs (LRFD) l Ii Page 11 DATE : 8/9/22 BY : ESY Solar Dead Load= (Module Wt= 64.2 lbs)+ (Rack Wt)+ (Ballast Wt= 6 x 32 = 192 lbs)= 270 lbs P total (D + 0.6W) = 270 + 0.6 x 677 = 677 lbs (ASD) M max = PL / 4 = 677 lbs x 1 0' / 4 = 1,693 lb-ft Assume a 2 ft strip of deck w allow = 83 psf x 2' = 166 lb/ft M allow = wl "2 / 8 = 166 lb/ft x ( 1 O' )"2 I 8 = 2,075 lb-ft M /Mallow= 1693 / 2075 = 0.82 < 1.0 OKAY Type PLB™-36 or HSB®-36 ■ 1½" Deep Roof Deck ■ Primer Painted or Galvanized ■ PLB-36 Deck used with Punchlok II System ■ HSB-36 Deck used with TSWs, BPs or Screws Dimensions ~,--------,. l 1 PLB-36 or HSB-36 36" HSB-36-SS ~~ Standard Interlocking Sidelap Screw Fastened Sidelap Deck Weight and Section Properties t 6" t l l 1¾· l 1 1 1 HSB-30 NESTABLE \. I Overlapping Sidelap Available 30" Wide (Special Order)6 Page 12 Weight Id for Moment Allowable Reactions per ft of Width (lb) due to Web Crippling Deflection One Flange Loading Two Flange Loading Gage Galv Painted Single Multi +s.n -Sen End Bearing Interior Bearing End Bearing Interior Bearing Span Span Length Length Length Length (psf) (psf) (in.4/ft) (in.4/ft) (in. 3/ft) (in.3/ft) 2" 3" 4" 3" 4" 2" 3" 4• 3• 4• 22 1.9 1.8 0.177 0.192 0.176 0.188 935 1076 1163 1559 1671 962 1078 1150 1935 20&4 20 2.3 2.2 0.219 0.231 0.230 0.237 1301 1492 1609 2190 2340 1413 1576 1675 2744 2947 118 2.9 2.8 0.302 0.306 0.314 0.331 2181 2484 2667 3714 3950 2551 2823 2987 4713 5038 16 3.5 3,4 0.381 0.381 0.399 0.410 3265 3699 3955 5607 5938 4018 4422 4660 7168 7631 Notes: 1. Section properties are based on F y = 50,000 psi. 2. Id is for deflection due to uniform loads. 3. Sett(+ or-) is the effective section modulus. 4. Multiply tabulated deck values listed above by the following adjustment factors to obtain acoustical deck section properties: Id for Moment Allowable Reactions per ft of Width {lb) Deflection One Flange Loading Deck Type Single Multi Span Span +Sen -Seff End Bearing Interior Bearing B -Acoustical 0.98 0.98 0.97 0.97 1.00 0.76 5. Allowable (ASD) reactions are based on web crippling, per AISI S100 Section C3.4, where O't= 1.70 for end bearing and 1.75 for interior bearing. Nominal reactions may be determined by multiplying the table values by Ow-RFD reactions may be determined by multiplying nominal reactions by 4>w = 0.90 for end reactlona and 0.85 for Interior reactions. 6. Diaphragm values for HSB-30 Nestable are outside the scope of Verco's Evaluation Report. 26 ■ VR4 VERCO DECKING, INC. www.vercodeck.com Type PLBTM-36 or HSB®-36 Allowable Uniform Loads (psf) DECK ______ SPAN (ft-in.) Page 13 SPAN GAGE CRITERIA 2'-0" 3'-0" 4'-0" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" T-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0' 11'-0" 12'-0" w ..J (!) z -u, w ..J m => 0 C w ..J D.. ii: I- Stress 300 300 220 141 116 98 83 22 U360 ♦♦♦ 287 121 62 47 36 28 U240 ••• ••• 182 93 70 54 42 U180 ••• ••• ••• 124 93 72 56 72 23 34 45 63 18 28 37 55 15 23 30 -----S-tr-e-ss--3-0_0 __ 3_0_0 __ 2_8_8 __ 1_84--15_2 __ 1_2_8_ 109 94 28 42 56 128 39 58 77 82 23 34 45 112 31 47 63 72 19 28 37 98 26 39 52 U360 ••• ••• 150 77 58 44 35 U240 ♦♦♦ ♦♦♦ 225 115 86 67 52 20 U180 ♦♦♦ ♦♦♦ ♦♦♦ 153 115 89 70 ---------- 18 16 22 20 Stress 300 300 300 251 208 174 149 U360 ••• ••• 207 106 79 61 48 U240 ♦♦♦ ♦♦♦ ••• 159 119 92 72 U180 ♦♦♦ ♦♦♦ ♦♦♦ 212 159 122 96 Stress 300 300 300 300 264 222 189 U360 ••• ••• 261 133 100 77 61 U240 ••• ••• ••• 200 150 116 91 U180 ••• ••• ♦♦♦ 267 200 154 121 Stress 300 300 235 150 124 104 89 L/360 ♦♦♦ ♦♦♦ ♦♦♦ ••• 122 94 7 4 U240 ••• ••• ••• ••• ••• ••• ••• U180 ♦♦♦ ••• ♦♦♦ ••• +++ ••• +♦♦ Stress 300 300 296 190 157 132 112 U360 ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ 146 113 89 163 49 73 97 77 59 ♦♦♦ ♦♦♦ 97 71 142 40 59 79 67 48 ••• ♦♦♦ 84 58 U240 ••• ••• ••• ••• ••• ♦♦♦ ••• ••• ••• U180 ♦♦♦ ♦♦♦ ••• ••• ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ 125 33 49 65 59 40 ♦♦♦ ♦♦♦ ------=s-tr-es-s--,3ccO--=o---=3--=o-=-o---=3-=-oo=----=-25=5=---2-=-1cc9,----1cc8c-c4-157 -1c--c3--=-5---,-11~8,- 74 48 71 ♦♦♦ 103 63 94 18 16 22 20 18 16 U360 ••• ••• ••• 258 194 149 117 94 76 U240 ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ 115 U180 ♦♦♦ ••• ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ••• ♦♦♦ Stress 300 300 300 300 271 228 194 167 U360 ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ 241 186 146 117 U240 ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ U180 ••• ••• ••• ••• ••• ♦♦♦ Stress 300 300 294 188 155 131 U360 ♦♦♦ ♦♦♦ 247 127 95 73 L/240 ••• ••• ••• ••• 143 110 U180 ♦♦♦ ♦♦♦ ••• ••• ••• ••• Stress 300 300 300 237 196 165 U360 ♦♦♦ ♦♦♦ 298 152 115 88 U240 ♦♦♦ ♦♦♦ ♦♦♦ 229 172 132 U180 ♦♦♦ ••• ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ Stress 300 300 300 300 274 230 U360 ••• ••• ••• 202 152 117 U240 ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ 228 175 L/180 ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ Stre11 300 300 300 300 300 285 L/360 ♦♦♦ ♦♦♦ ••• 251 189 145 L/240 ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ 283 218 ♦♦♦ ♦♦♦ 111 58 86 ♦♦♦ 140 69 104 139 196 92 138 18-4 243 114 172 ♦♦♦ ♦♦♦ 96 46 69 92 121 56 83 111 169 74 110 147 209 92 137 ♦♦♦ 146 95 143 ••• 128 78 118 ♦♦♦ ♦♦♦ 84 73 38 31 56 46 75 62 105 93 45 37 68 56 90 74 14 7--1--=2-=-9- 60 49 90 74 120 99 182 110 74 61 112 92 49 13 19 25 64 16 23 31 87 22 32 43 110 27 41 54 52 33 49 ♦♦♦ 66 40 59 ♦♦♦ 92 53 79 ♦♦♦ 113 65 98 ♦♦♦ 65 26 39 52 82 31 47 62 115 41 62 82 142 51 77 43 11 16 21 57 13 20 26 78 18 27 36 99 23 34 46 46 28 42 ♦♦♦ 59 33 50 ♦♦♦ 82 44 66 ••• 101 55 83 ♦♦♦ 58 22 33 43 73 26 39 52 102 35 52 69 127 43 65 L/180 ♦♦♦ ♦♦♦ ♦♦♦ ♦♦♦ ••• ♦♦♦ 229 183 149 123 102 86 SN footnotes on page 27. www.vercodeck.com VERCO DECKING, INC. 39 9 14 18 51 11 17 22 70 15 23 31 88 19 29 39 42 24 35 ♦♦♦ 53 28 43 ♦♦♦ 73 38 56 ••• 91 47 70 ♦♦♦ 52 18 28 37 66 22 33 44 92 29 44 59 114 37 55 73 35 8 12 15 46 10 14 19 63 13 20 26 80 17 25 33 38 20 30 ••• 47 24 37 ♦♦♦ 66 32 48 64 82 40 60 80 47 16 24 32 59 19 29 38 50 103 31 47 63 29 6 9 12 38 7 11 14 52 10 15 20 66 13 19 25 31 15 23 30 39 18 27 37 55 24 36 48 68 30 45 60 39 12 18 24 49 14 21 29 68 19 28 38 85 24 35 47 24 4 7 9 32 6 8 11 44 8 11 15 55 10 14 19 26 12 18 23 33 14 21 28 46 19 28 37 57 23 35 46 33 9 14 18 41 11 17 22 57 15 22 29 71 18 27 36 VR4 ■ 29 Orlea Eng/Merlng Structural & Bridge Engineers 9750 Miramar Rd., Suite 310 Phone #: (858) 335--7643 San Diego, CA 92126 www.orle2.com Project No. : 249.002-22 PROJECT: Emerald Lake PV Beam Loading W16x26 Trib = 10'-0" Max DL = 7 psf x 1 o· = D solar = 8 psf x 10' = Lr= 16.9 psf x 10' = W=12.1 psfx10'= W14x22 Trib = 8.61' DL = 7 psfx 8.61 ' = D solar= 8 psf x 8.61' = Lr= 18.8 psf x 8.61' = W = 13.8 psfx 8.61' = W12x16 Trib = 7.25' DL = 7 psfx 7.25' = D solar= 8 psf x 7.25' = Lr= 20 psf x 7.25' = W = 18.2 psf X 7.25' = 70 lb/ft 80 lb/ft 169 lb/ft 121 lb/ft 61 lb/ft 69 lb/ft 162 lb/ft 119 lb/ft 51 lb/ft 58 lb/ft 145 lb/ft 132 lb/ft Page 14 DATE : 8/9/22 BY: ESY Note: Solar is only on a portion of the beam. Solar load applied to whole beam in analysis -conservative Page 15 Section Set Sedion Sets &.x I W16X26 W14ll22 W12x16 W16x26 ,6,.#1 ~ 43 W14x22 ~ W12x16 M /416 Envelope Only Solution Orie2 Engineering, Inc. SK -1 ESY Aug 11 , 2022 at 8:26 AM 9eams.r3d Dead Load Page 16 ·-•~;JllllllillI:JlliillJJJlllllLEJJ]Jllllllll]L:q, -.051k/ftr--r-r--r-~~~ Jr:111 rr rnr::~ r:r nnJY 111,ll Loads: BLC 1, D Envelope Only Solution Orie2 Engineering, Inc. ESY SK-2 Aug 11, 2022 at 8:27 AM Beams.r3d Solar Dead Load y X -.058k/ft ~vwTITI1www1 v y w l JIU 1 TI L nnk loads: BLC 2, Osolar Envelope Only Solution Orie2 Engineering, Inc. ESY Page 17 SK-3 Aug 11, 2022 at 8:27 AM Beams.r3d Roof Live Load -.169k/ft ~ -.145klft iunm,rrrn: 1Jm1nn: 1n tle Loads: BLC 3, Lr Envelope Only Solution Orie2 Engineering, Inc. ESY Page 18 SK-4 Aug 11, 2022 at 8:27 AM Beams.r3d Page 19 Wind Load (Down) --'''),m:rnnmul:llll1Jilffiril:mcuur;rmru:n:mrmJIJ a, -"']mUUWJJJJJ]JJllillJWJ~ Loads: BLC 4, W Envelope Only Solution Orie2 Engineering, Inc. ESY SK-5 Aug 11, 2022 at 8:27 AM Beams.r3d Code Check (Bending) Page20 I 1Code~ &.x (Ent) No Clalc: > 1.0 .90-1.0 .75-.90 .50-.75 I 0.-.50 .52 ~1 ~ M .44 ,?;k4 M .17 2)j6 Member Code Checks Displayed (Enveloped) Envelope Only Solution Orie2 Engineering, Inc. SK-6 ESY Aug 11 , 2022 at 8:27 AM Beams.r3d IIIRISA Company Designer Job Number Model Name Orie2 Engineering, Inc. ESY (Global) Model Settings Display Sections for Member Cales 5 Max Internal Sections for Member Cales 97 Include Shear Deformation? Yes Increase Nailina Caoacitv for Wind? Yes Include Warpina? Yes Trans Load Btwn lntersectina Wood Wall? Yes Area Load Mesh (in"2) 144 Merae Tolerance (in) .12 P-Delta Analvsis Tolerance 0.50% Include P-Delta for Walls? Yes Automatically Iterate Stiffness for Walls? Yes Max Iterations for Wall Stiffness 3 Gravity Acceleration (fVsec"2) 32.2 Wall Mesh Size (in) 24 Eiaensolution Converaence Toi. (1.E-) 4 Vertical Axis y Global Member Orientation Plane xz Static Solver Sparse Accelerated Dynamic Solver Accelerated Solver Hot Rolled Steel Code AISC 14th(360-10): ASD Adiust Stiffness? Yes(lterative) RISAConnection Code AISC 14th(360-10): ASD Cold Formed Steel Code AISI S100-16: ASD Wood Code AWC NDS-15: ASD Wood Temoerature < 100F Concrete Code ACI 318-14 Masonrv Code ACI 530-13: AS D Aluminum Code AA ADM1-10: ASD -Buildina Stainless Steel Code AISC 14th(360-10): ASD Adiust Stiffness? Yes( Iterative) Number of Shear Reaions 4 Reaion Spacina Increment (in) 4 Biaxial Column Method Exact lntearation Parme Beta Factor (PCA) .65 Concrete Stress Block Rectanaular Use Cracked Sections? Yes Use Cracked Sections Slab? Yes Bad Framina Warninas? No Unused Force Warninos? Yes Min 1 Bar Diam. Spacina? No Concrete Rebar Set REBAR SET ASTMA615 Min % Steel for Column 1 Max % Steel for Column 8 Page 21 Aug 11 , 2022 8:27 AM Checked By: DJF RISA-3O Version 17 .0.4 [Z:\PROJECTS\249 -HES\002-22 -Emerald Lake PV\calcs\Beams.r3d] Page 1 IIIRISA Company Designer Job Number Model Name Orie2 Engineering, Inc. ESY {Global) Model Settings, Continued Seismic Code ASCE 7-16 Seismic Base Elevation (ft) Not Entered Add Base Weiqht? Yes CtX .02 CtZ .02 TX (sec) Not Entered T Z (sec) Not Entered RX 3 RZ 3 Ct Exo. X .75 Ct Exo. Z .75 SD1 1 sos 1 S1 1 TL (sec) 5 Risk Cat I or II Drift Cat Other OmZ 2 OmX 2 CdZ 1 CdX 1 RhoZ 1 RhoX 1 Hot Rolled Steel Properties Label E fksil G lksil Nu Therm 1/1 E5 .Densitvlklf . Yield(ksil Rv 1 A992 29000 11154 .3 .65 49 50 1.1 2 A36 Gr.36 29000 11154 .3 .65 .49 36 1.5 3 A572 Gr.50 290_Q0 111 54 .3 .65 .49 50 1.1 4 A500 Gr.B RND ?9000 111 54 3 65 .527 42 1.4 5 A500 Gr.B Rect 29000 11154 .3 .65 .527 46 1.4 6 A53 Gr.B 29000 11154 .3 ~i:; .11.Q 3!'i 1.6 7 A1085 29000 11154 .3 .65 .49 50 1.4 Hot Rolled Steel Section Sets Label Shaoe Tvge Desinn List Material Desinn .. . A [in2] 1 W16x26 W16X26 Beam None A992 Tvnical 7.68 2 W14x22 W14X22 Beam None Jl.QQ2 T"nir<>I 6.4!:i 3 W12x16 W12X16 Beam None A992 T"nical 4.71 Joint Coordinates and Temperatures Label X lftl Y fftl Z lftl Temn [E) 1 N1 0 0 0 0 2 N2 35.75 0 0 0 3 N3 0 -10 0 0 4 N4 30 -10 0 0 5 NS 0 -20 0 0 6 N6 1~4 -?O 0 0 Page 22 Aug 11, 2022 8:27 AM Checked By: DJF I= u(ls§jl Rt__ 65 1.1 58 1.2 65 1.1 58 1.3 !'i8 1.3 60 1.2 65 1.3 I ui.n4 I i.n4) J lin41 9.59 301 .262 7 199 .208 2.82 103 .103 Detach From Diac hragrn__ RISA-30 Version 17.0.4 [Z:\PROJECTS\249 -HES\002-22 -Emerald Lake PV\calcs\Beams.r3d] Page2 IIIRISA Company Designer Job Number Model Name Orie2 Engineering, Inc. ESY Hot Rolled Steel Design Parameters I abel Shaoe Lenalb[ftl I bvvffl] Lbzzffl] 1 M1 W16x26 35.75 2 2 M2 W14x22 30 2 3 M3 W12x16 15.4 2 Joint Loads and Enforced Displacements LcomQJQP-fftl I COMP-b t[ftl [ .!nm ..• Kvv 2 2 2 Page23 Aug 11, 2022 8:27 AM Checked By: DJF Kzz Cb Function Lateral Lateral Lateral Joint Label L.D,M Direction Magnitude[(k,k-ft), (in.rad), (k*sA2Jft, k*sA2*ft)] No Data to Print ... M1 -.07 0 0 2 M2 -.061 0 0 3 M3 -.051 0 0 Member Distributed Loads (BLC 2 : Dso/ar) Member I abel Direction Start Maanituderkltt F ksfl End Magnituderk Start I ocationrtt, l=nd l ocation[ft..%] 1 M1 y -.08 -.08 0 0 2 M2 y -.069 -.069 0 0 3 M3 y -.058 -.058 0 0 M1 -.169 0 2 M2 -.1 62 0 3 M3 -.145 0 Me abe nitude[k/ft F ks0 1 M1 -.121 2 M2 -.119 3 M3 -.132 Basic Load Cases BLC Descriotion Cateaorv X Gravitv Y Gravitv Z Gravitv Joint Point Distrih•i.. Area/M Surfac .. 1 D DL -1 3 2 Dsolar DL 3 3 Lr RLL 3 4 w WL 3 RISA-3O Version 17.0.4 [Z:\PROJECTS\249 -HES\002-22 -Emerald Lake PV\calcs\Beams.r3d] Page 3 IIIRISA Company Designer Job Number Model Name Orie2 Engineering, Inc. ESY Load Combinations (Continued) Page 24 Aug 11 , 2022 8:27 AM Checked By: DJF Descri tion S ... P ... S ... B ... F ... Fa... BLC Fa ... BLC Fa .. BL 3 D + Dsolar + 0.6W Y .. Y DL 1 WL .6 4 D + Dsolar + 0.75Lr + O ... Y .. Y DL 1 WL .45 Load Combination Design Descrintion ASIF CD Servir,e Hot Rolled Cold For Wood Concrete M:.sonrv Aluminum Stainless Connecti . 1 D + Lr 1.25 Yes Yes Yes Yes Yes Yes Yes Yes Yes 2 D + Dsolar + Lr 1 25 Yes Yes Yes Yes Yes Yes Yes Yes Yes 3 D + Dsolar + 0.6W 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes 4 D + Dsolar + 0.75Lr + 0.4 ... 1.6 Yes Yes Yes Yes Yes Yes Yes Yes Yes Envelope Joint Reactions Joint X fkl LC Y fkl LC z [ls] LC MX fk.:f!) LC MY (k-ftl LC MZ fk-ftl LC 1 N1 max 0 4 6.387 4 0 4 LOCKED 0 4 0 4 2 min 0 1 4.446 3 0 1 LOCKED 0 1 0 1 3 N2 max 0 4 6.387 4 0 4 0 4 0 4 0 4 4 min 0 1 4.446 3 0 1 0 1 0 1 0 1 5 N3 max 0 4 4.907 4 0 4 0 4 0 4 0 4 6 min 0 1 3.352 3 0 1 0 1 0 1 0 1 7 N4 max 0 4 4.907 4 0 4 LOCKED 0 4 0 4 8 min 0 1 3.352 3 0 1 LOCKED 0 1 0 1 9 N5 max 0 4 2.257 4 0 4 0 4 0 4 0 4 10 min 0 1 1.573 3 0 1 0 1 0 1 0 1 11 N6 max 0 4 2.257 4 0 4 LOCKED 0 4 0 4 12 min 0 1 1.573 3 0 1 LOCKED 0 1 0 1 13 Totals: max 0 4 27.104 4 0 4 14 min 0 1 18.742 3 0 1 Envelope Member Section Deflections Service Member Sec x finl LC v linl LC z [in] LC x Rotate r . LC (n.U,LY.' Ra LC (n_) I /7' Ratio LC 1 M1 1 max 0 4 0 4 0 4 0 4 NC 4 NC 4 2 min 0 1 0 1 0 1 0 1 NC 1 NC 1 3 2 max 0 4 -.933 3 0 4 0 4 459.945 3 NC 4 4 min 0 1 -1 .34 4 0 1 0 1 320 16 4 NC 1 5 3 max 0 4 -1.309 3 0 4 0 4 327.711 3 NC 4 6 min 0 1 -1.881 4 0 1 0 1 228.114 4 NC 1 7 4 max 0 4 -.933 3 0 4 0 4 459.945 3 NC 4 8 min 0 1 -1.34 4 0 1 0 1 320.16 4 NC 1 9 5 max 0 4 0 4 0 4 0 4 NC 4 NC 4 10 min 0 1 0 1 0 1 0 1 NC 1 NC 1 11 M2 1 max 0 4 0 4 0 4 0 4 NC 4 NC 4 12 min 0 1 0 1 0 1 0 1 NC 1 NC 1 13 2 max 0 4 -.629 3 0 4 0 4 572.723 3 NC 4 14 min 0 1 -92 4 0 1 0 1 391 ?fi 4 NC 1 15 3 max 0 4 -.882 3 0 4 0 4 408.065 3 NC 4 16 min 0 1 -1.291 4 0 1 0 1 278 773 4 NC 1 17 4 max 0 4 -.629 3 0 4 0 4 572 7?J. 3 NC 4 1R min 0 1 -.92 4 0 1 0 1 391 26 4 NC 1 19 5 max 0 4 0 4 0 4 0 4 NC 4 NC 4 20 min 0 1 0 1 0 1 0 1 NC 1 NC 1 21 M3 1 max 0 4 0 4 0 4 0 4 NC 4 NC 4 22 min 0 1 0 1 0 1 0 1 NC 1 NC 1 23 2 max 0 4 -.077 3 0 4 0 4 2398 079 3 NC 4 RISA-3O Version 17.0.4 [Z:\PROJECTS\249 -HES\002-22 -Emerald Lake PV\calcs\Beams.r3d) Page4 IIIRISA Company Designer Job Number Model Name Orie2 Engineering, Inc. ESY Envelope Member Section Deflections Service (Continued) Member C::o,-x linl LC v linl LC z finl LC x Rotate I ... LC In\ Uv' Ra .. LC 24 min 0 1 -.111 4 0 1 0 1 1670.502 4 25 3 max 0 4 -.108 3 0 4 0 4 1708.632 3 26 min 0 1 -.155 4 0 1 0 1 1100.212 4 27 4 max 0 4 -.077 3 0 4 0 4 2398 079 3 28 min 0 1 -.111 4 0 1 0 1 1670.502 4 29 5 max 0 4 0 4 0 4 0 4 NC 4 30 min 0 1 0 1 0 1 0 1 NC 1 1 2 3 112.653 141.0 Page25 Aug 11, 2022 8:27 AM Checked By: DJF 'n' Uz' Ratio LC NC 1 NC 4 NC 1 NC 4 NC 1 NC 4 NC 1 RISA-3O Version 17.0.4 [Z:\PROJECTS\249 -HES\002-22 -Emerald Lake PV\calcs\Beams.r3d) Page 5