HomeMy WebLinkAboutPRE 2022-0056; WORTH DUPLEX; Admin Decision Letter..
December 15, 2022
John Wankner
4681 Park Drive, Unit B
Carlsbad, CA 92008
SUBJECT: PRE 2022-0056 (DEV2022-0196) -WORTH DUPLEX
APN: 207-150-47-00
Thank you for submitting a preliminary review to convert an existing two-family dwelling unit into a two-
unit condominium located at 4681 Park Drive. The project site, which comprises of a 0.09-acre site, is
currently developed with a two-family dwelling unit (duplex).
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans, policies, and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal, new plans, policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and zoning designations for the property are as follows:
a. General Plan: R-23 Residential, 15-23 dwelling units per acre (du/ac)
b. Zoning: R-W (Residential Waterway Zone)
c. Coastal Zone: The site is located in the Deferred Certification Area of the Coastal Zone
2. The project requires the following permits:
a. Planned Development (PUD) -the City Planner will be the decision-making authority
b. Minor Subdivision (MS) -the City Planner will be the decision-making authority
c. Minor Variance -See comment on setback standards below -the City Planner will be the decision-
making authority
Community Development Department
Planning Division j 1635 Faraday Avenue Carlsbad, CA 92008-7314 j 442-339-2600 www.carlsbadca.gov
PRE 2022-0056 (DEV2022-0196) -WORTH DUPLEX
December 15, 2022
Page 2
d. Coastal Development Permit (CDP) -As the project site is located within the Deferred Certification
Area of the Coastal Zone, approval of a Coastal Development Permit {CDP) is required from the
California Coastal Commission {CCC). Action on the CDP cannot be taken until the PUD, MS and
Minor Variance is approved by the City Planner. In addition, please be advised that staff cannot
approve the building permit until the CCC approves the CDP. Coordination with CCC staff early
on in the process is therefore strongly encouraged.
3. Conversion of Existing Buildings to Planned Developments. Any application for the conversion of an
existing building to a condominium shall be subject to Carlsbad Municipal Code (CMC) Section
21.45.110 which includes the following:
a. Building Plans and Gas/Electric Plan. The formal application must include building plans indicating
how the building relates to present building code (CMC Title 18) and zoning (CMC Title 21) code
regulations and where modifications are required to comply.
In addition, the application must include a letter from San Diego Gas and Electric explaining the
plans to connect the gas and electric system to separate systems are acceptable.
b. Notice to Tenants and Findings. Each prospective and existing tenant of the proposed
condominium project shall receive written notice of the proposed conversion in accordance with·
Section 66452.8 and 66452.9 of the California Government Code.
In addition to all other required findings for a subdivision, the city council shall make all of the
findings set forth in Section 66427.1 of the California Government Code {Subdivision Map Act).
4. Development Standards. The proposed conversion of the existing building into condominiums require
compliance with all applicable development standards listed in CMC Chapter 21.45 -Planned
Developments. Plans submitted with a formal application to convert the existing building into
condominiums will need to clearly identify compliance with all applicable standards. The comments
provided below are not inclusive of all the requirements. Please refer to the CMC for all requirements.
a. Visitor Parking. Per CMC 21.45.060, Table C, C.6, projects with 10 or fewer units require 0.30 space
per unit. When calculating visitor parking spaces, if the calculation results in a fractional number,
the required number shall always be rounded up to the nearest whole number. Therefore, based
on two units, one visitor parking space must be provided.
For projects with 10 or fewer units, required visitor parking may be located on a driveway,
provided that all dwelling units have driveways with a depth of 20 feet or more (typically located
in front of a unit's garage). For this project, which provides one of the two required residential
parking spaces for each unit as uncovered parking (compliant to Planned Development
requirements for the R-W zone), these spaces can be provided within a driveway leading to the
uncovered parking spaces. So long as the depth of that driveway is at least 20 feet.
Plans submitted with a formal application must demonstrate compliance with this requirement
by labeling the visitor parking space, or spaces, and providing dimensions for all spaces.
. , ..
PRE 2022-0056 (DEV2022-0196) -WORTH DUPLEX
December 15, 2022
Page 3
b. Lot Coverage. The maximum lot coverage is 60 percent of the net developable area. Lot coverage
includes exterior structures such as stairs, overhanging balconies, stories that overhang a ground
level, garages, roof eaves that extend more than 30 inches from the face of the building and any
structures over 30 inches in height. Plans submitted with a formal application must provide a lot
coverage breakdown that includes all applicable portions of the building for each unit.
c. Building Height. The building height is limited to 40 feet and two stories if the roof pitch is 3:12 or
greater, and 35 feet if less than a 3:12 roof pitch is provided.
d. Setbacks. The setback from a public street for a residential structure is 10 feet and a garage with
direct entry is 20 feet. The two existing single-car garages are located less than 20 feet from the
front property line. The project will require the approval of a Minor Variance, consistent with CMC
Chapter 21.50, to modify the distance required by this development standard.
e. Resident Parking. Two spaces per unit. In the R-W Zone, the two (2) required parking spaces may
be provided as one (1) covered space and one (1) uncovered space.
f. Private Recreational Space. The minimum total area of private recreational space is 200 square
feet per unit. If this space is provided at the ground level, the minimum dimension is 15 feet and
cannot have a slope gradient greater than five percent. Attached patio covers and decks or
balconies may project into a required private recreational space if the depth of the project is not
more than six feet, measured from the wall of the dwelling that is contiguous to the
patio/deck/balcony. Plans submitted with an application is required to clearly identify and fully
dimension the private recreational space areas for each unit.
g. Storage Space. 480 cubic feet of storage space per unit is required. Required storage space shall
be separately enclosed for each unit and be conveniently accessible to the outdoors. A garage
(12' x 20' one-car or larger) satisfies the required storage space per unit.
Land Development Engineering:
1. The project will need to submit a tentative parcel map with the discretionary application.
Subsequently, the project will need to apply for a Certificate of Compliance in Lieu of Parcel Map.
2. Please be advised that a more in-depth review of the proposed development will occur with the
discretionary permit application, when a more complete design of the project is provided.
Building:
1. Demising wall shall be compliant with CRC section 302.3, penetrations per CRC section 302.4 and
sound insulation requirements of CBC section 1206.
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or · online at
PRE 2022-0056 (DEV2022-0196) -WORTH DUPLEX
December 15, 2022
Page4
https://www.carlsbadca.gov/departments/community-development/planning/planning-applications-
forms. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the
website address shown; select Department Listing; select Planning Home Page. Please review all
information carefully before submitting.
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Kyle Van Leeuwen at the email below. You may also contact each department individually as
follows:
• Planning Division: Kyle Van Leeuwen, Associate Planner, at kyle.vanleeuwen@carlsbadca.gov
• Land Development Engineering: Emad Elias, Associate Engineer, at emad.elias@carlsbadca.gov
Sincerely,
7JVG~
ERIC LARDY
City Planner
EL:KVL:JC
c: Worth Trust, Tom Worth, 3571 Turquoise Lane, Oceanside, CA 92056
Emad Elias, Project Engineer
·l:aseriisc~/ Fi••COfJJ1'
Data Entry
.. '